STREET LIGHTING FUSE N B W R WIRING DIAGRAM TO TX CT's W-BUSBAR R-BUSBAR B-BUSBAR B B W R W + W R TO TX NEUTRAL BAR E GPO N R R B W R TO TX EARTH BAR NOTE: 500 750 1000 D STOCK CODE COMPARTMENT LV COMPARTMENT HV WIDTH LENGTH 1000KVA LV CUBICLE HV CUBICLE 20 4 2 29 9 10 25 COMPARTMENT TRANSFORMER FRONT VIEW WITH DOORS REMOVED DES DRN CKD APPD SCALE ISSUED ALL DIM. IN mm DRAWING NUMBER AMDT A3 DRAFTING STANDARD TO A.S.1100 CAD PRODUCT - DO NOT AMEND MANUALLY DESCRIPTION AMENDMENTS NO DRN DATE CKD APPD NORTHERN TERRITORY POWER STANDARD DRAWING 185 185 648 2200 500 750 1000 STOCK CODE 11KV SUBSTATION 22KV SUBSTATION 500 750 1000 D STOCK CODE 500 750 1000 D STOCK CODE RMU TYPE 3 WAY KKT RMU TYPE 3 WAY KKT RMU TYPE 4 WAY KKTK RMU TYPE 4 WAY KKTK 1677 1677 1677 1677 1554 1554 1554 920 1280 FINS COOLING INCLUDING COMPARTMENT TRANSFORMER 3 0 ISSUED FOR CONSTRUCTION C.C NOV'11 S.C. B.C. REFER TO SHEET 5 NOV '11 N.T.S. B.C. A.T. C.C B.C. 415336 415337 415339 415347 415346 415345 415344 415343 415342 S02-1-7-17_1 SUBSTATION kVA SUBSTATION kVA SUBSTATION kVA SUBSTATION kVA OVERALL HEIGHT OVERALL HEIGHT OVERALL HEIGHT OVERALL HEIGHT 500kVA, 750kVA & 1000kVA GENERAL ARRANGEMENT SHEET 1 OF 5 PACKAGE MK.2 SUBSTATIONS CABLE TYPE 11KV 22KV - 414778 95SQMM AL 240SQMM AL 414779 300SQMM CU 414780 - 120SQMM CU 240SQMM CU 414783 - 414781 - 414782 HV CABLE TERMINATION STOCK CODES 415338 415340 415341 1000kVA - 2000A (1000Ax2) 750kVA - 2000A (1000Ax2) 500kVA - 1000A DISCONNECTOR WITH COPPER LINKS 2200 1974 985 D 1554 1 A.T. SEP'13 B.C. B.S. FOR: 1000 or 630A. STRIPPLE FUSE UNIT WEBER OR JEAN MULLER DRIESCHER WEGBERG RMU MINEX-C OR MINEX 24KV REFER TO S02-1-4-22 RMU AS REQUIRED MINEX/MINEX-C DREISCHER WEGBERG OR 4 WAY (KKTK) 3 WAY (KKT) 400SQMM AL 501664 - - 501665 35SQMM CU AND MINEX TYPE RMU ADDED NOTE 15, 400 AND 35sqmm TERMINATION 2 A.T. FEB'14 B.C. B.S. S S S S 32 33 1807 1807 1807 1807 1864 LENGTH 500 AND 750KVA 1000KVA DETAILS ADDED NOTE 16 ADDED, NOTE 13 AMENDED. 3 A.T. JUN'14 B.C. B.C. NOTE 7 REMOVED WITH M10 BOLTS. SWITCH NUMBERS SHALL BE RIVETED TO A 40 x 40 ALUMINIUM ANGLE CHANNEL. ANGLE CHANNEL SHALL BE BOLTED TO THE SWITCHGEAR MOUNTING FRAME, SHOWN IN SHEET 3, 16. NETWORK ENGINEERING. SINGLE CONSUMER INSTALLATIONS THAT HAVE A MAXIMUM DEMAND NOT GREATER THAN 100KVA CAN INSTALL A 300KVA MK2 SUBSTATION UPON REQUEST TO POWER AND WATER 15. MANUFACTURER. HV CABLES CONNECTING THE TRANSFORMER BUSHINGS TO THE SWITCHGEAR FUSED TEE-OFF SHALL BE TERMINATED USING DEAD BREAK ELBOWS AND INSTALLED BY THE SUBSTATION 14. REFER TO S02-2-6-31 FOR FOUNDATION DETAILS, SO2-2-6-17 FOR EASEMENT DETAILS AND S02-2-5-09 FOR EARTHING ARRANGEMENTS. 13. ALL HV CABLES SHALL BE SECURELY CLAMPED BELOW THEIR RESPECTIVE HV BUSHINGS USING THE UNISTRUT CHANNELS IN THE FOUNDATION SLAB. 12. ALL HV CABLE EARTH SCREENS SHALL BE CONNECTED TO THE HV EARTH BAR. 11. LARGEST CABLE TO BE TERMINATED TO HV SWITCHGEAR IS 400SQMM ALUMINIUM. 10. ALL HV CABLE TERMINATIONS SHALL BE VIA 630A TYPE C SCREENED DEADBREAK CONNECTIONS. 9. REFER TO DRAWING S02-1-2-20. THE CABLE TERMINATION FRAME CAN BE USED TO ASSIST IN TERMINATION OF HV CABLES TO THE DRIESCHER MINEX-C SWITCHGEAR. 8. UNLESS SPECIFIED OTHERWISE, PACKAGE SUBSTATIONS SHALL BE SUPPLIED WITH LV PANEL INCLUDING STRIPPLE SWITCH FUSE UNITS. 6. WITH R.W.B. FROM REAR OF CABINET TO FRONT. ALL COLOUR CODING SHALL BE ON UN-STRIPPED CABLE. CABLES IN THE HV AND LV COMPARTMENTS SHALL HAVE HEAT SHRINK COLOURED SLEEVES TO MATCH PHASE AND CONNECTED TO SWITCHGEAR 5. EACH CABLE ENTERING/LEAVING SUBSTATION IS TO HAVE A DESTINATION, TAG REFER TO S2-1-8-25. 4. THIS DRAWING TO BE READ IN CONJUNCTION WITH THE PWC SPECIFICATIONS STS 001. 3. LIFTING LUGS ARE NOT DETACHABLE. 2. COMPRESSION OVER INSULATION TO EXCLUDE MOISTURE ARE ESSENTIAL. REFER TO S02-2-2-10. COMPRESSION LUGS ARE TO BE USED ON ALL LV CABLE CONNECTIONS FOR XLPE AND OTHER ALUMINIUM CONDUCTORS. CABLE LUGS WITH FINAL 1.

A3 · PDF filethe cable termination frame can be used to assist in termination of hv cables to the driescher minex-c ... (no load) amps amps vector ... drain / sample ball

  • Upload
    phamtu

  • View
    214

  • Download
    1

Embed Size (px)

Citation preview

Page 1: A3 · PDF filethe cable termination frame can be used to assist in termination of hv cables to the driescher minex-c ... (no load) amps amps vector ... drain / sample ball

L10-R

STREET LIGHTING FUSE

S2

S2

B

S2-

B

NVT

BVT

WVT

R

N4-BK

L31-B

L21-W

L11-R

ISOLATOR OUTPUT

ISOLATOR OUTPUT

ISOLATOR OUTPUT

WIRING DIAGRAM

TO TX CT's

R

S1

W

S1

B

S1

S2

RW

S2

S1-

B

S2-

W

S1-

W

S2-

R

S1-

R

ISOLATOR INPUT

ISOLATOR INPUT

W-BUSBAR

R-BUSBAR

B-BUSBAR

E

E

ECONNECTOR JOINT

S2 S1S2 S1S1

FUSE

BCT

BCT

WCT

R

ISOLATOR INPUT

S11-W

S21-W

L30-B

AMMETER

W

+

L20-W

WFUSE

RFUSE

TO TX NEUTRAL BAR

N4

N3

EE

L13-R

E

GPO N

FLURO & GPO FUSE

R

N3-BKL14-R R

B W R

DOOR

SWITCH

N2

E

FLURO'S

N1

E

FLURO'S

L14-R

L15-R

N1-

BK

N2-

BK

L3

2-

B

L2

2-

W

L12-

R

TO TX EARTH BAR

NOTE:

500 750 1000

D

STOCK CODE

COMPARTMENT

LV

COMPARTMENT

HV

WIDTH

LE

NG

TH

10

00

KV

A

LV CUBICLE HV CUBICLE

20 4 2

29

9

10

25

COMPARTMENT

TRANSFORMER

FRONT VIEW WITH DOORS REMOVED

DES

DRN

CKD

APPD

SCALE

ISSUED

ALL DIM. IN mm

DRAWINGNUMBER

AMDT

A3

DRAFTING STANDARD TO A.S.1100 CAD PRODUCT - DO NOT AMEND MANUALLY

DESCRIPTION

AMENDMENTS

NO DRN DATE CKD APPDNORTHERN TERRITORY

POWER STANDARD DRAWING

185

185

648

2200

500 750 1000

STOCK CODE

11KV SUBSTATION 22KV SUBSTATION

500 750 1000

D

STOCK CODE

500 750 1000

D

STOCK CODE

RMU TYPE

3 WAY KKT

RMU TYPE

3 WAY KKT

RMU TYPE

4 WAY KKTK

RMU TYPE

4 WAY KKTK

1677 1677

1677 1677

1554

1554 1554

920 1280

FINS

COOLING

INCLUDING

COMPARTMENT

TRANSFORMER

30 ISSUED FOR CONSTRUCTION C.C NOV'11 S.C.B.C.

REFER TO SHEET 5

NOV '11

N.T.S.

B.C.

A.T.

C.C

B.C.

415336 415337 415339

415347415346415345415344415343415342

S02-1-7-17_1

SUBSTATION kVA SUBSTATION kVA

SUBSTATION kVA SUBSTATION kVA

OVERALL HEIGHT OVERALL HEIGHT

OVERALL HEIGHT OVERALL HEIGHT

500kVA, 750kVA & 1000kVA

GENERAL ARRANGEMENT SHEET 1 OF 5

PACKAGE MK.2

SUBSTATIONS

CABLE TYPE 11KV 22KV

- 41477895SQMM AL

240SQMM AL 414779

300SQMM CU 414780 -

120SQMM CU

240SQMM CU

414783

- 414781

- 414782

HV CABLE TERMINATION STOCK CODES

415338 415340 415341

1000kVA - 2000A (1000Ax2)

750kVA - 2000A (1000Ax2)

500kVA - 1000A

DISCONNECTOR WITH COPPER LINKS

2200

197

4

98

5

D 1554

1 A.T. SEP'13 B.C. B.S.

FOR: 1000 or 630A.

STRIPPLE FUSE UNIT

WEBER OR JEAN MULLER

DRIESCHER WEGBERG RMU

MINEX-C OR MINEX 24KV

REFER TO S02-1-4-22

RMU AS REQUIRED

MINEX/MINEX-C

DREISCHER WEGBERG

OR 4 WAY (KKTK)

3 WAY (KKT)

400SQMM AL 501664 -

- 50166535SQMM CU

AND MINEX TYPE RMU ADDED

NOTE 15, 400 AND 35sqmm TERMINATION

2 A.T. FEB'14 B.C. B.S.

S S S S

32

33

1807

1807

1807

1807

18

64

LE

NG

TH

50

0

AN

D

75

0K

VA

1000KVA DETAILS ADDED

NOTE 16 ADDED, NOTE 13 AMENDED.

3 A.T. JUN'14 B.C. B.C.NOTE 7 REMOVED

WITH M10 BOLTS.

SWITCH NUMBERS SHALL BE RIVETED TO A 40 x 40 ALUMINIUM ANGLE CHANNEL. ANGLE CHANNEL SHALL BE BOLTED TO THE SWITCHGEAR MOUNTING FRAME, SHOWN IN SHEET 3,16.

NETWORK ENGINEERING.

SINGLE CONSUMER INSTALLATIONS THAT HAVE A MAXIMUM DEMAND NOT GREATER THAN 100KVA CAN INSTALL A 300KVA MK2 SUBSTATION UPON REQUEST TO POWER AND WATER 15.

MANUFACTURER.

HV CABLES CONNECTING THE TRANSFORMER BUSHINGS TO THE SWITCHGEAR FUSED TEE-OFF SHALL BE TERMINATED USING DEAD BREAK ELBOWS AND INSTALLED BY THE SUBSTATION 14.

REFER TO S02-2-6-31 FOR FOUNDATION DETAILS, SO2-2-6-17 FOR EASEMENT DETAILS AND S02-2-5-09 FOR EARTHING ARRANGEMENTS.13.

ALL HV CABLES SHALL BE SECURELY CLAMPED BELOW THEIR RESPECTIVE HV BUSHINGS USING THE UNISTRUT CHANNELS IN THE FOUNDATION SLAB.12.

ALL HV CABLE EARTH SCREENS SHALL BE CONNECTED TO THE HV EARTH BAR.11.

LARGEST CABLE TO BE TERMINATED TO HV SWITCHGEAR IS 400SQMM ALUMINIUM.10.

ALL HV CABLE TERMINATIONS SHALL BE VIA 630A TYPE C SCREENED DEADBREAK CONNECTIONS. 9.

REFER TO DRAWING S02-1-2-20.

THE CABLE TERMINATION FRAME CAN BE USED TO ASSIST IN TERMINATION OF HV CABLES TO THE DRIESCHER MINEX-C SWITCHGEAR.8.

UNLESS SPECIFIED OTHERWISE, PACKAGE SUBSTATIONS SHALL BE SUPPLIED WITH LV PANEL INCLUDING STRIPPLE SWITCH FUSE UNITS.6.

WITH R.W.B. FROM REAR OF CABINET TO FRONT. ALL COLOUR CODING SHALL BE ON UN-STRIPPED CABLE.

CABLES IN THE HV AND LV COMPARTMENTS SHALL HAVE HEAT SHRINK COLOURED SLEEVES TO MATCH PHASE AND CONNECTED TO SWITCHGEAR 5.

EACH CABLE ENTERING/LEAVING SUBSTATION IS TO HAVE A DESTINATION, TAG REFER TO S2-1-8-25.4.

THIS DRAWING TO BE READ IN CONJUNCTION WITH THE PWC SPECIFICATIONS STS 001. 3.

LIFTING LUGS ARE NOT DETACHABLE.2.

COMPRESSION OVER INSULATION TO EXCLUDE MOISTURE ARE ESSENTIAL. REFER TO S02-2-2-10.

COMPRESSION LUGS ARE TO BE USED ON ALL LV CABLE CONNECTIONS FOR XLPE AND OTHER ALUMINIUM CONDUCTORS. CABLE LUGS WITH FINAL1.

Page 2: A3 · PDF filethe cable termination frame can be used to assist in termination of hv cables to the driescher minex-c ... (no load) amps amps vector ... drain / sample ball

DESCRIPTION LIST

*SERIAL NUMBER, YEAR OF MANUFACTURE AND

IMPENANCE (4.00% NOM.) STAMPED AFTER TEST

297 X 420A3

AMENDMENTS

NO DESCRIPTION DRN DATE APPD

DES

DRN

CKD

APPD

SCALE

ISSUED

ALL DIM. IN mm

DRAWINGNUMBER

AMDT

A3

DRAFTING STANDARD TO A.S.1100

CKD

CAD PRODUCT - DO NOT AMEND MANUALLY

POWER STANDARD DRAWING

B.C.

TIE DOWN POINT

23

3 24 31 30

15

5

0

20 4 2

29

9 10 25

A B C

14

86

7 1

PROPERTY OF

POWER & WATER CORPORATION

721-0591-01/B

1

1

Plan of tank

1

C10

kVA 500 MINERAL

Phase

Frequency

Volts

(no load)

Amps

Amps

Vector group

Insulation level

Cooling type

3

50

11000

433

26.2

667

Dyn1

LI95AC28/AC10

ONAN

Hz

HV

LV

HV

LV

Insul. liquid Oil

Temp. rise Oil/Wdg

Total mass

Untanking mass

Liquid volume

Pressure min/max

(kPa abs)

Year of manufacture

55/60

2975

938

575

50/130

Impedance %

°C

kg

kg

l

This is a Sealed Transformer

OFF CIRCUIT TAPSELECTOR DE-ENERGISE BEFORE CHANGING TAPS

To AS 60076 (MEPS compliant)

B10 A10 a2b2c2 n

0591

A10

6

7

3-9

9-2

8-35

4-84

7-43

5-72

C10B10

A10

C10

BA

1 6-5

B10C

LVCONN%POSHVACROSS

c2b2a2

ACROSS

nc2

a2

b2

11000

11275

11550

11825

12100

10450

10725

100.0

102.5

105.0

107.5

110.0

95.0

97.5

433

7

7

4

4

1

2 3 5 6 8 9

1

2 3 5 6 8 9

74

1

2 3 5 6 8 9

FRONT VIEW WITH DOORS REMOVED

HV SWITCHGEAR REFER ITEM 2

PLAN VIEW WITH UNIT COVER REMOVED

2200

1864

267

150

1677

225

648

45 1200

SERIAL NUMBER

MANUFACTURER LOGO

S02-1-7-17_2 2

0 ISSUED FOR CONSTRUCTION C.C NOV’11 S.C. NOV ’11

N.T.S.

S.C.

A.T.

C.C

B.C.

HV BUSHING 630A SCREW TYPE (M16)1.2.3.

OFF CIRCUIT TAPSELECTOR 7 POSITION -5 % TO +10% WITH LOCKING FACILITIES4.5.

PHASE, EXTRA INSULATION ON ’b’ PHASE BUSBAR (TX TO SWITCHGEAR), TEST BLOCK, DOUBLE GPO, 4 MINI TERASAKI CIURCUIT BREAKERS 10A 10kA, 3 x 63A FUSE BASE’S FOR

HAVE BOTH ENDS FITTED WITH COLOURED HEATSHRINK TO ID. PHASE PROVISION FOR MOUNTING PAWC NUMBER PLATE, STREET LIGHTING PANEL ON INSIDE 6.OF LV DOOR OR ON LV SWITCHGEARHV DOOR INTER-LOCKED WITH LV DOOR WITH OVERCENTRE LATCH, OWNERSHIP PLATE,7.RMU OPERATION LABEL & OPERATING HANDLE SUPPORT (INSIDE DOOR)3 x HINGES AND DOOR STAYLV DOOR WITH SWING HANDLE (3 POINT LOCKING) WITH PROVISION FOR PAD 8.LOCKING, DANGER PLATE (STICK-ON) , 3 x HINGES AND DOOR STAYINSULATED NEUTRAL BAR 50 x 6.3 TINNED COPPER COMPLETE WITH 11 TAPPED HOLES 9.M10 & REMOVABLE LINK TO EARTH BAR

10.

12.HV/LV COMPARTMENT FLUORECENT LIGHT 36W13.LIFTING LUGS SLOT 40x6014.RATING AND DIAGRAM PLATE 15.THERMOMETER POCKET16.FLUSH TYPE OIL GAUGE MARKED AT 15°C (BACKGROUND ON WALL OF TANK PAINTED 17.WHITE BEHIND PERSPEX) PRESSURE RELIEF VALVE18.

SEALING PLUG19.20.21.22.

COOLING FINS23.CUBICLE COVER WITH INSULATION ON UNDERSIDE OF COVER AND FITTED WITH 24.HANDLES TO AID REMOVAL OF COVERBASE FRAME 150 x 50 CHANNEL GALVANISED WITH GENERATOR CABLE ACCESS POINT 25.(COVER PLATE BOLT ON)

26.27.28.29.

LIGHT SWITCH BRACKET30.EMAIL ANTENNA MOUNTING LUG (CENTRE PANEL)31.

LV BUSHING ZEP 2/3/4m HOLE IN PALM Ø14

LV SWITCHGEAR, GENERATOR STRIP, 5 x 630A FUSE STRIPS, MDI FITTED TO ’b’

SWITCHGEAR CIRCUIT & WIRING DETAILS) CONNECTING SWITCHGEAR BUS WORK TO

LV EARTH BAR 50 x 6.3 TINNED COPPER COMPLETE WITH 10 HOLES Ø13

DRAIN / SAMPLE BALL VALVE Ø25 NOM.

FILLER CAP Ø40 NOM.

GENERAL ARRANGEMENT SHEET 2 OF 5

PACKAGE

SUBSTATIONS

11.

DRIESCHER WEGBERG RMU

MINEX-C OR MINEX 24KV

1 JUL’13 B.C. B.C.A.T.MINEX RMU ADDED

FUTURE STREET LIGHTING, (REFER SHEET 5 FOR FLUORESCENT LIGHTING AND

1213

20

n a b c

CT 800/5A FOR MDI (MOUNTED ON BUSBAR TO PHASE LV BUSHINGS, ONLY ’a’ PHASE SHOWN)

HV COMPARTMENT SUITABLE FOR FITTING DRIESCHER MINEX-C 24kV 4 WAY RMU’S

16

18 19 17

29

2 A.T. FEB’14 B.C. B.C.ITEMS 32, 33 ADDED

32.33.

ALUMINIUM RIGHT ANGLE 40 x 40SWITCH NUMBER IDENTIFICATIONPLATE REFER S02-1-8-14

Page 3: A3 · PDF filethe cable termination frame can be used to assist in termination of hv cables to the driescher minex-c ... (no load) amps amps vector ... drain / sample ball

LV EARTH BAR DETAIL (ITEM 28)50 x 6.3 COPPER TINNED BAR

LV EARTH BAR DETAIL (ITEM 25)50 x 6.3 COPPER TINNED BAR

LV EARTH BAR DETAIL (ITEM 24)50 x 6.3 COPPER TINNED BAR

LV EARTH BAR DETAIL (ITEM 23)50 x 6.3 COPPER TINNED BAR

0

25

50

0

20

14

8

223

298

37

3

44

8

523

650

67

0

0

20

70

120

17

0

220

27

0

320

37

0

420

47

0

520

620

64

0

0

25

50

8 x M10x1.5 Tapped Holes

0

25

50

0

20

70

120

17

0

220

27

0

320

37

0

420

47

0

520

620

699

718

8 x M10x1.5 Tapped Holes

0

25 61

86

12

6

166

206

24

6

28

6

37

1

44

6

48

6

52

6

55

1

58

8

613

0

25

50

297 X 420A3

AMENDMENTS

NO DESCRIPTION DRN DATE APPD

DES

DRN

CKD

APPD

SCALE

ISSUED

ALL DIM. IN mm

DRAWINGNUMBER

AMDT

A3

DRAFTING STANDARD TO A.S.1100

CKD

CAD PRODUCT - DO NOT AMEND MANUALLY

POWER STANDARD DRAWING

DEC 04

N.T.S.

...

C.C.

K.I.

R.C.

LV REMOVABLE LINK BAR

BUSBAR AND EARTHING LAYOUT

GENERAL ARRANGEMENT SHEET 3 OF 5

PACKAGE

SUBSTATIONS

S02-1-7-17_3 10 ISSUED FOR CONSTRUCTION NOV’11A.T. B.C. S.C.

1 A.T. FEB’14 B.C. B.C.

MOUNTING POINT FOR ITEM 32

SWITCH NUMBER MOUNTING ADDED

Page 4: A3 · PDF filethe cable termination frame can be used to assist in termination of hv cables to the driescher minex-c ... (no load) amps amps vector ... drain / sample ball
Page 5: A3 · PDF filethe cable termination frame can be used to assist in termination of hv cables to the driescher minex-c ... (no load) amps amps vector ... drain / sample ball