A1400 AIR RD – FAAC Redundant Automation31/03/2015
• Generality
• Composition
• Characteristics
• Selling configuration
• Accessories
SOMMARIO
31/03/2015
2
A1400 AIR RD - Generality
New automation for sliding automatic doors in escape routes:
FAAC A1400 AIR RD
Automation in compliance with European Standard EN 16005 and TUV certificated.
Project created with the specific intent ofgetting a new automation for escape routesin compliance with Machinery Directive2006/42 / EC.
Entire route has been consolidated with theobtaining of the TUV mark and T.R.O.C.(Technical Report Of Conformity).
Document that certifies compliance with theMachinery Directive and to the followingharmonized standards:• EN 16005:2012
• EN ISO 12100:2010
• EN 61000-6-2:2005
• EN 61000-6-3:2007
• EN 60335-1:2013
• EN 60335-2-103:2011
• EN 13849-1:2008 PL. “D” CAT. 3
• EN 13849-2:2008
A1400 AIR RD - Generality
31/03/2015
3
Why use a redundant automation in escaperoute?
A1400 AIR RD - Generality
The new automation FAAC A1400 AIR RD, for pedestrian door installed on escape,ensures the opening of the door in all circumstances.In case of danger or emergency the door opening is ensured by redundant safety systemcertificate EN 13849 Pl. ‘D'.
As per standard EN 16005 the doors redundant are used in the same fields of applicationof the sliding doors with break-out system, where emergency opening is effected bypressing or manual push.
In particular they are used in those situations where the breakout system can generatedanger for the passage of people and / or vehicles in the neighboring areas during therotation of the doors themselves.
A1400 AIR RD - Generality
31/03/2015
4
What does it mean to have redundantautomation FAAC A1400 AIR RD installedon an escape?
A1400 AIR RD - Generality
1. It means having an entrance in compliance with Machinery Directive 2006/42/CEand TUV certificate.
2. It means having the certainty that even in case of failure, power failure orbreakdown, the escape route is always free and guaranteed.
3. It means having an automation EN16005 certified for the attainment of 1,000,000cycles.
4. It means having a door that performs an auto-diagnosis at least once a day.
5. It means being able to automate a door with leaves up to 200 kg, also only incrystal, and make however that the door becomes an escape route in compliancewith current standards in terms of safety.
6. It means being able to automate a door with the transit space up to 3 make andmake however that the door becomes an escape route in compliance with currentstandards in terms of safety.
7. It means decreasing overall installation time compared to a traditional entrancewith mechanical break-out system.
8. It means having an automation with advanced technology and up to date.
A1400 AIR RD - Generality
31/03/2015
5
What is the difference between redundantautomation FAAC A1400 AIR RD and astandard FAAC A100 / A140?
A1400 AIR RD - Generality
Situation A1400 AIR RD redundant automation
A100/A140Standard automation
Power failure the door opens and remains open until power is restored
The door can continue to run normally until it reaches the minimum level of the battery, after which the door performs the last operation, opens or closes
A1400 AIR RD - Generality
Situation A1400 AIR RD redundant automation
A100/A140Standard automation
Power failure the door opens and remains open until power is restored
The door can continue to run normally until it reaches the minimum level of the battery, after which the door performs the last operation, opens or closes
Low battery With low battery, the door opens and remains open until the battery has recharged, even with main power presents.
The door continues to move while the battery recharges. If in the meantime missing the main power the door is blocked in the position where it is, until the power supply is restored.
Situation A1400 AIR RD redundant automation
A100/A140Standard automation
Power failure the door opens and remains open until power is restored
The door can continue to run normally until it reaches the minimum level of the battery, after which the door performs the last operation, opens or closes
Low battery With low battery, the door opens and remains open until the battery has recharged, even with main power presents.
The door continues to move while the battery recharges. If in the meantime missing the main power the door is blocked in the position where it is, until the power supply is restored.
Passage from AUTOMATIC to NIGHT / MANUAL
Using the SDK EVO with password or key mandatory (EN16005). As the door stops being an escape and then the passage must be done by authorized persons.
Using SD KEEPER by pressing a button. Anyone can put the door in NIGHT / MANUAL, use the lock with the key optional.
31/03/2015
6
Situation A1400 AIR RD redundant automation
A100/A140Standard automation
Maintenance cycles The door to the achievement of maintenance cycles, settable from SDK EVO, starts sounding the alarms at every movement. On the manual are reported maintenance and periodic replacement to do.
There are no warnings.
A1400 AIR RD - Generality
Situation A1400 AIR RD redundant automation
A100/A140Standard automation
Maintenance cycles The door to the achievement of maintenance cycles, settable from SDK EVO, starts sounding the alarms at every movement. On the manual are reported maintenance and periodic replacement to do.
There are no warnings.
Cycle of system self-diagnosis.
At least once every 24 hours. It’s possible to see the door open independently if the door is not used for at least 24 hours (excluding NIGHT function)
Never executed.
Situation A1400 AIR RD redundant automation
A100/A140Standard automation
Failure / malfunction of the system (including sensor XDT3)
The door opens immediately within 15 seconds and stays open until the disappearance of the failure or malfunctioning of the system, while also providing an audible warning, only if the can’t open.
The door locks in the position where it is located (also closed) until the disappearance of the failure or malfunction of the system.
A1400 AIR RD - Generality
Situation A1400 AIR RD redundant automation
A100/A140Standard automation
Failure / malfunction of the system (including sensor XDT3)
The door opens immediately within 15 seconds and stays open until the disappearance of the failure or malfunctioning of the system, while also providing an audible warning, only if the can’t open.
The door locks in the position where it is located (also closed) until the disappearance of the failure or malfunction of the system.
Using opening safetysensors (side screen)
The door will ignore the information of the sensor up to 80% of the opening, after which you can decide whether to stop or precede in LOW ENERGY in accordance with the Standard.
The door considers the information of the sensor for the whole duration of the opening, after which you can decide whether to stop or precede in LOW ENERGY, in accordance with the Standard.
31/03/2015
7
• Generality
• Composition
• Characteristics
• Selling configuration
• Accessories
SOMMARIO
A1400 AIR RD – Composition• Support profile in extruded aluminum (the same as the automation A140)
• Front covers in natural or anodized aluminum height 100mm or 140mm (the same as the automation A140)
• 36Vdc main gear motor with encoder (SafeZone - the same as the automation A140)
• 36Vdc secondary gear motor with adjustable belt tensioning
• 12mm transmission belt
• E1400 RD microprocessor control unit with auto-control of the part related to the redundant safety (EN 13849 PL."d" Cat.3) and built-in lock, battery, photocell boards and display with buttons for programming.
31/03/2015
8
A1400 AIR RD – Composition
• 230Vac switching power supply unit derived from the A140 (Greentech).
• Terminal dedicated to each sensor or accessory colorful and removable.
• Update firmware and download / upload of some information (configurations, timer, log) via USB stick (FAT32/500mA).
• Emergency batteries auto-controlled involved in case of power failure, opening the door according to EN 16005 (the same as the automation A140)
The traction unit of the automation is composed by a main motor with encoderwhich communicates constantly the correct position of the leaves to thesophisticated electronic card which, thanks to a double control circuit, occurs atleast once every 24 hours the integrity of the system to safeguard the safety duringall movement.
In case of need, error or failure of the system the opening of the door is ensuredanyway by the second auxiliary motor, which opens the leaves and these remainopen until the fault is not resolved.
The leaves are moved by a new 12mm belt which allows for speeds andaccelerations in compliance with EN 16005.
Opens 80% of the open width in 3 sec !!
A1400 AIR RD – Composition
31/03/2015
9
• Generality
• Composition
• Characteristics
• Selling configuration
• Accessories
SOMMARIO
MODEL A1400 AIR RD single leaf A1400 AIR RD double leaf
Length [mm] from 1700 to 6100 from 1900 to 6100
Depth [mm] 128,7 128,7
Total depth with self-supporting beam * [mm] 183,7 183,7
Height [mm] 100-140 100-140
Weight [kg] MIN. 24 - MAX 49 MIN. 27 - MAX. 51
No. of leaves 1 2
MAX weight of a leaf
NOTE:
The weight of the leaf has a variable value, not
proportional to the size of the leaf L. This is
related to the speed in the opening that must
remain constant regardless of the weight and size
of the leaf, in reference to the standard EN
16005:2012.
The weight depends on the leaf
dimensions:
The weight is independent of
leaf dimensions:
L [m] P max [Kg] 120 [Kg]
≤ 1,4 200
1,6 180
1,7 150
1,8 130
2 120
2,2 125
2,4 140
2,6 160
2,8 180
3 200
Passage opening (Vp) [mm] from 800 to 3000 from 900 to 3000
Beam length [mm] Vp x 2 +100 Vp x 2 +100
Maximum framed leaf thickness [mm] 65 65
A1400 AIR RD – Characteristics
31/03/2015
10
A1400 AIR RD single leaf A1400 AIR RD double leaf
Power supply voltage 230 V~ 50 Hz 230 V~ 50 Hz
MAX absorbed power [W] 140 140
Utilisation frequency 100% 100%
Main motor (with encoder) powered at 36V powered at 36V
Auxiliary motor (without encoder) powered at 36V powered at 36V
Max. accessories load 1A, 24V 1A, 24V
Backup battery time/date Lithium CR2032 3V Lithium CR2032 3V
Backup battery handling NiMh 24V 1800 mAh NiMh 24V 1800 mAh
Traction by toothed belt by toothed belt
Opening/closing speed adjustment (empty)
[cm/s]
10... 75 20... 150
Partial opening adjustment 5%... 95% of total opening 5%... 95% of total opening
Pause time adjustment [s] 0... 30 0... 30
Night pause time adjustment [s] 0... 240 0... 240
Anti-crushing device on opening/closing on opening/closing
Protection sensors monitoring (EN 16005:2012) may be excluded may be excluded
Energy Saving function may be enabled may be enabled
Drive Low Energy may be enabled may be enabled
Operating ambient temperature [°C] -20... +55 -20... +55
Automation protection degree IP 23 (internal use) IP 23 (internal use)
A1400 AIR RD – Characteristics
As per standard EN 16005 the automatic sliding doors with a clear opening width upto 2000 mm are open to at least 80% within 3 seconds after activation by the actuatorin the direction of exodus or at latest after 5 sec to switch off the power supply.
The timing of opening for doors wider must be calculated in proportion.
0
50
100
150
200
250
800 1000 1200 1400 1600 1700 1800 2000 2200 2400 2600 2800 3000
Leaf
wei
ght
(Kg)
Passage Width (mm)
A1400 AIR RD – SINGLE LEAF
< 3sec > 3sec
The graph shows thetrend of single-leaf maxweight according to thepassage width to meet theopening times.
For double leaves, the max weight will be always 120 kg regardless of the transit area.
A1400 AIR RD – Characteristics
31/03/2015
11
• Generality
• Composition
• Characteristics
• Selling configuration
• Accessories
SOMMARIO
1° leaf base kit
Code Language
10514001 Italian
10514002 Franch
10514003 German
10514004 English
10514005 Spanish
10514006 Dutch
A1400 AIR RD – Selling configuration
31/03/2015
12
A1400 AIR RD – Selling configuration
Code 105140PA (the language must be selected when ordering)
• Sliding door A1400 AIR RD PA 1 mobile leaf
• Sliding door A1400 AIR RD PA 2 mobile leaves
• Sliding door A1400 AIR RDA PA 1 mobile leaf self-supporting
• Sliding door A1400 AIR RDA PA 2 mobile leaves self-supporting
• Generality
• Composition
• Characteristics
• Selling configuration
• Accessories
SOMMARIO
31/03/2015
13
A1400 AIR RD – Accessories
Codice Descrizione
790019 SDK EVO function keypad
105104 XDT3 Double tecnology sensor
105128 Belt RPP SILVER 12mm SVL8(55m pack)
Specific accessories
XDT3 Double tecnology sensor FOR ESCAPE ROUTE
This new double technology sensor, certified EN 16005 and EN 13849 PL. "D", isintended to be used with the new automation A1400 AIR RD for doors installed onescape and it must be mounted in the direction of escape, while for other direction canbe used a traditional double technology sensor , as XDT1 and XV1.
It is also able to detect the movement of the person, optimizing the time of opening ofthe door, making close the door immediately after the passage or intercepting the sidepassage openings avoiding unwanted and unnecessary waste of energy (ENERGYSAVING).
XDT3
XV1 o XDT1
31/03/2015
14
XDT3 XDT1 XV1
Type of output - Solid-state-relay
- Frequency output
- Current source output (dedicated for door on escape route)
Solid-state-relay Solid-state-relay
Mic
row
ave
Adjusting radar angle Vertical Horizontal Vertical Horizontal Vertical
N° radar antenna 2 –field wide or narrow 2 –field wide or narrow
1 – field wide only
Adjusting of size field radar detection
Display or remote control 10 levels
Display or remote control 10 levels
Trimmer
Adjusting radar immunity Display or remote control 9 levels
Display or remote control 9 levels
Dip-switch 3 levels
Adjusting radar detection –movement direction
Display or remote control 8 settings
Display or remote control 8 settings
Dip-switch 2 settings
XDT3 Double tecnology sensor FOR ESCAPE ROUTE
Comparison between the main characteristic of XDT3 and the other two sensors XDT1and XV1
XDT3 XDT1 XV1
Bright spot on the floor for quick adjustment of the infrared curtain
Yes (4 spot) Yes (4 spot) No Spotfinder necessaty (785187)
In
frared
N° max of infrared curtain with 24 spot each
2 2 2
Adjusting of amplitude infrared curtain
Display or remote control 10 settings
Display or remote control 10 settings
1 lens for wide field
Adjusting infrared immunity Display or remote control 7 levels
Display or remote control 7 levels
Dip-switch 3 levels
Adjusting infrared persistence time(time after which the sensor is adapted to the environment and the door closes - at least 30 "to EN16005)
Display or remote control 10 settings (from 0 sec to
infinite)
Display or remote control 10 settings
(from 0 sec to infinite)
Fix 30 sec
Use of TF1 remote control Yes Yes No
Diagnostic Yes on display Yes on display No
XDT3 Double tecnology sensor FOR ESCAPE ROUTE
Comparison between the main characteristic of XDT3 and the other two sensors XDT1and XV1
31/03/2015
15
SDK EVO Keypad function
All operating functions and advancedprogramming (with password INSTALLER) orbasic (with password access USER) arefacilitated by four keys that guide the user throughthe menus.
The MANUAL or NIGHT functions are accessibleusing a code number or a key, as required by EN16005.
NOTE:SDK EVO is not compatible with A100-A140series
This new keypad, supplied as an accessory, it is always equipped with a largegraphic display that allows a full access to all parameters of the door.
12mm transmission belt The leaves are moved by a new oversized belt of 12mm which allows for speeds andaccelerations in compliance with EN 16005
For both motors were added plastic containment to prevent the belt comes out duringthe acceleration and braking,