1 A new HEPA solution for gas turbine inlet air filtration Tom Kelmartin, PE W.L. Gore & Associates, Inc. March 14, 2013 [email protected]

A new HEPA solution for gas turbine inlet air · PDF fileA new HEPA solution for gas turbine inlet air filtration ... •New HEPA Filtration Solution •Case Studies . 3 ... blocked

Embed Size (px)

Citation preview

1

A new HEPA solution for gas turbine inlet

air filtration

Tom Kelmartin, PE

W.L. Gore & Associates, Inc. March 14, 2013

[email protected]

2 2013 W. L. Gore & Associates

Agenda

• The Problem

• What is HEPA Filtration?

• New HEPA Filtration Solution

• Case Studies

3 2013 W. L. Gore & Associates

The Problem

• Gas turbines consume enormous amounts of air for combustion – GE 7FA: 360 Billion Ft3/year

• That air contains contaminants large and small – Dirt, salt , moisture, sand, soot, insects, corrosive gasses….

• Dirty air causes lost efficiency and can ultimately destroy a turbine – Compressor fouling, blocked cooling passages, blade erosion,

low and high temp corrosion, foreign object damage

4 2013 W. L. Gore & Associates

The Problem

• Inlet air filtration aims to reduce contaminants in the air

stream without imposing a large pressure drop penalty

• Conventional filters are very inefficient at capturing sub-

micron particles and allow liquids and dissolved

contaminants to pass

• HEPA filters are better at capturing submicron particles,

but in the past have been challenged by relatively high

pressure drops and limited life

5

What is HEPA Filtration?

(High Efficiency Particulate Air)

Overview

6 2013 W. L. Gore & Associates

Sub-Micron Distribution in Urban Air

Particle Distribution (urban)

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

Particle Size [µm]

Particle

Number

(normalized)

100 times more 0.1μ particles than 0.5μ

Visible particle = 40µ

7 2013 W. L. Gore & Associates

Particle Size Range of Current

Standards (Don’t measure below 0.3µ)

Particle Distribution (urban)

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

Particle Size [µm]

Particle

Number (normalized)

EN779

ASHRAE 52.2

US Standard EU Standard

8 2013 W. L. Gore & Associates

HEPA Standard EN1822 Addresses <0.3

Micron Issue

Particle Distribution (urban)

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

Particle Size [µm]

Particle

Number (normalized)

EN779

ASHRAE 52.2

EN1822

9 2013 W. L. Gore & Associates

To Capture the Performance of HEPA Filters,

Need a Different Test (EN1822) and Scale

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

Particle Size [µm]

Particle

Number (normalized)

0

10

20

30

40

50

60

70

80

90

100

Particle

Capture

Efficiency [%]

Cellulose

Nanofibers / Synthetic

Nanofibers / Cellulose

MERV15/F9

GORE H12/E12

MPPS*

Minimum required for H12 rating

*Most Penetrating Particle Size

10 2013 W. L. Gore & Associates

Filter Classifications

>99.5%

>95%

>85%

95% ≤ Em

85% ≤ E1 ≤95%

95% < E1

80% ≤ Em ≤95%

75% ≤ E1 ≤85%

80% ≤ Em ≤90%

E1 <

75%

Efficiency

MERV

15

MERV

16

F9 0.4μm/

0.3-1.0 avg.

H10/E10 MPPS

H11/E11 MPPS EPA/HEPA

Filters

H12/E12 MPPS

MERV

14

F8 0.4μm/

0.3-1.0 avg.

Fine Filters

MERV

13

F7 0.4μm/

0.3-1.0 avg.

EN1822 2005/2009

ASHRA

E 52.2

EN779 Particle Size Filter Class

11 2013 W. L. Gore & Associates

What is a HEPA Filter?

HEPA Rating Efficiency at

MPPS

H10/E10 > 85%

H11/E11 > 95%

H12/E12 > 99.5%

• Defined by EN1822 standard. Were called “H”, now “E”

ratings

• Rating is based on the minimum capture rate of the

Most Penetrating Particle Size (MPPS), typically

about 0.1 microns

12 2013 W. L. Gore & Associates

There Are Different HEPA Ratings For a

Reason

Filter Grade

2

4

6

8

10

12

14

Uncaptured

Pollutants

[kg/yr]

Representative pollutants which

pass through a 25 MW turbine

during one year of operation

F9 H10 E12 GORE® Turbine Filter

29 lb/yr

135X

12.3 lb/yr

X= 0.09 lb/yr

F9

Filter Grade

(MERV 15)

E10

Filter Grade

GORE®

Turbine

Filters

Best

MERV

15 Filter

Turbine will

still foul

due to low

efficiency

filters

13 2013 W. L. Gore & Associates

Pre-filter Layer removes

Bulk of large Particles

High Efficiency Membrane Removes

Submicron Dust, Water, and Salt

High Strength Backer

Provides Burst Strength

GORE® Turbine Filters: High Efficiency (E12)

with Low Pressure Drop

14 2013 W. L. Gore & Associates

GORE Membrane Technology Waterproof Media Provides Water & Salt Retention

Air can pass

through the membrane

Salt dust, water, and aqueous salt

solutions are repelled

15

Stopping the Fouling from small particles

Example of benefits realized by Turbine

Operators

Overview

16 2013 W. L. Gore & Associates

Coastal Operation With Coal Dust,

Losing 10% Power Between Offline

Washes - (RB211-30MW) - UK

Coal Yard

Plant

17 2013 W. L. Gore & Associates

Constant Power Output with Gore Filters

Coastal Power Plant (RB211-30MW) - UK

Current Filters

3 off-line washings/yr.

-5

-4

-3

-2

-1

0

1

2

3

4

5

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400

Days

Po

we

r V

ari

an

ce

fro

m

co

rre

cte

d t

arg

et

(MW

)

F9 standard filter

GORE Turbine Filter

offline compressor

washing and filter

replacement

offline

compressor

washing

Gore Filters

0 off-line washings/yr.

18 2013 W. L. Gore & Associates

Reduced Engine Wear:

Coastal & Coal Dust - (RB211-30MW) - UK

20,000 hrs w/ no on- or off-line

washes

19 2013 W. L. Gore & Associates

Coastal Petrochemical Plant (Texas) That

Cannot Shutdown for 1 Year

GORE® E12 Turbine

Filters With

Coalescers

20 2013 W. L. Gore & Associates

Compressor Efficiency

Power Load

Temperature

Frame 6B 8,000+ hrs

No Wash

Constant Power Output with Gore Filters Petrochemical Plant (GE Frame 6B - 35MW) -

Texas

21 2013 W. L. Gore & Associates

Constant Power Output with Gore Filters Petrochemical Plant (GE 6B – 35MW) – Texas

90.2% (GORE)

87.6% (F8)

34.4 MW (GORE)

31.0 MW (F8)

7,850 Hrs

Compressor Efficiency

Power Load

GE Frame 6B

3.4 MW Gain

2.6% Gain

22

LM6000 after >2 years with GORE® Turbine Filters

After 18500 hrs.

After 8500 hrs.

After 15075 hrs.

23 2013 W. L. Gore & Associates

Clean Power Plant Turbine – Oregon Mitsubishi 501G (265MW)

After 2000 hours After 4000 hours After 10,000 hours

24 2013 W. L. Gore & Associates

Eliminating Off-Line Washes - Confirmed

via Boroscope and Wash Water

Comparison

Current

Gore

25 2013 W. L. Gore & Associates

GORE® HEPA Turbine Filters Eliminate

Compressor Fouling:

Simple retrofit

• Similar initial pressure drop

• Similar filter life

26 2013 W. L. Gore & Associates

Should I Invest in HEPA Filtration?

1. Compare power output versus previous experience. Power output will be effectively constant with Gore filters. Can also measure compressor efficiency as a proxy for power output

2. Quantify value of stopping off-line washes (availability, cost of shutdown with no power output). Gore product eliminates off-line washes

3. Quantify value of constant heat rate versus previous increases, fuel savings

4. Compare reduced costs due to elimination of extensive compressor section cleaning during scheduled major maintenance

5. Measure blade or rotor corrosion rates over time.

27

W. L. Gore & Associates GmbH

Wernher-von-Braun-Str. 18 • D-85640 Putzbrunn •

Germany

Phone: +49 89 4612-2211 • Fax: +49 89 4612-2302

E-mail: [email protected]

www.gore.com

W. L. Gore & Associates, Inc.

101 Lewisville Road • Elkton, MD 21921 • USA

Phone: +1 410 506-3300 • Fax: +1 410 506-3494

W. L. Gore & Associates GmbH Middle East - Abu

Dhabi

Al Niyadi Building • Airport Road • Abu Dhabi • UAE

Phone: +971 2 4437749 • Fax: +971 2 4437748

MORE POWER, LESS

WEAR