Upload
others
View
22
Download
1
Embed Size (px)
Citation preview
A high-performance line
of Japanese-engineered
guidewires designed to
respond to the artistry
of your technique.
Visit bostonscientific.com/SENTAI to learn more.
Each SENTAI guidewire is unique, providing you with enhanced control at every turn. The distinctive design
of a stainless steel core and proprietary Inner Coil Technology combine for an optimal combination of
torqueability, shape retention, and rail support.
Stainless steel inner coil affixed directly to the distal end of the guidewire core
Improved durability and ease of shaping
Exceptional torqueability without whipping
Inner Coil Technology
One-piece stainless steel core with innovative compound-taper
Exceptional 1:1 torque response
Excellent trackability and pushability in tortuous anatomy
Optimal rail support for outstanding device delivery through even the most challenging anatomy
MARVEL
SAMURAI
SAMURAI RC
FIGHTER
HORNET
HORNET10
HORNET14
MARVEL
SAMURAI
SAMURAI RC
FIGHTER
HORNET
HORNET10
HORNET14
Workhorse Wires
Specialty Crossing Wires
SAMURAI™ Guidewire Inner Coil Technology
SAMURAI™ RC Guidewire Inner Coil Technology
FIGHTER™ Guidewire
Make your go-to wire a warrior. SAMURAI’s innovative design provides effortless tip shaping, exceptional torque performance, and optimal tactile feedback.
FIGHTER is armed for battle. The polymer jacket and tapered tip enable best-in-class crossability and steerability through complex lesions.
Artful navigation at its best. With enhanced flexibility, trackability, and lubricity, SAMURAI RC is a versatile wire that can be used as both a frontline and specialty wire.
Our frontline guidewires give you the power to choose an everyday wire that fits your personal technique.
Each of our specialty crossing wires is uniquely designed to give you the tools you need to treat a wide range of complex patients.
*Moderated hydrophilic coating over spring coil (Reduced coating on distal 1 cm)
Tip Load 0.5 gf
Tip Radiopacity 4 cm
Tip Diameter0.014”
Tip StyleInner Coil
Technology
CoverSpring Coil
Coating Moderated
Hydrophilic*
Penetration Force
37 gf/mm2
Tip Load 1.5 gf
Tip Radiopacity 3.5 cm
Tip DiameterTapered 0.009”
Tip StyleCore-to-tip
CoverClear Polymer
over Coils
Coating Hydrophilic
Tip Load 1.2 gf
Tip Radiopacity 4 cm
Tip Diameter0.014”
Tip StyleInner Coil
Technology
CoverSpring Coil
Coating Hydrophilic
MARVEL
SAMURAI
SAMURAI RC
FIGHTER
HORNET
HORNET10
HORNET14
MARVEL
SAMURAI
SAMURAI RC
FIGHTER
HORNET
HORNET10
HORNET14
MARVEL
SAMURAI
SAMURAI RC
FIGHTER
HORNET
HORNET10
HORNET14
HORNET™ Guidewires
MARVEL™ Guidewire
HORNET
HORNET 10
HORNET 14
Be a hero with MARVEL, the workhorse wire that puts you in command. The full length hydrophilic coating, outstanding torqueability, and enhanced support make this wire the ideal choice to treat any case, simple to complex.
Pick your power with the HORNET line of highly crossable wires that puts 1:1 precision in your hands. Featuring the smallest tip profile available, there’s a HORNET wire for every challenge.
Penetration Force
31 gf/mm2
Tip Load 1.0 gf
Tip Radiopacity 3.5 cm
Tip DiameterTapered 0.008”
Tip StyleCore-to-tip
CoverSpring Coil
Coating Hydrophilic
Penetration Force
308 gf/mm2
Tip Load 10.0 gf
Tip Radiopacity 3.5 cm
Tip DiameterTapered 0.008”
Tip StyleCore-to-tip
CoverSpring Coil
Coating Hydrophilic
Penetration Force
432 gf/mm2
Tip Load 14.0 gf
Tip Radiopacity 3.5 cm
Tip DiameterTapered 0.008”
Tip StyleCore-to-tip
CoverSpring Coil
Coating Hydrophilic
Tip Load 0.9 gf
Tip Radiopacity 3 cm
Tip Diameter0.014”
Tip StyleCore-to-tip
CoverSpring Coil
Coating Hydrophilic
MARVEL
SAMURAI
SAMURAI RC
FIGHTER
HORNET
HORNET10
HORNET14
MARVEL
SAMURAI
SAMURAI RC
FIGHTER
HORNET
HORNET10
HORNET14
Specialty Crossing WiresTip Load and Penetration Force Testing
14
10
8
6
4
2
1
0.5
10 20 30 40 50 60 100 200 300 400
FielderTM XT
GaiaTM First
Gaia Third
Gaia Second
Penetration Force (gf/mm2)
Hydrophilic
Hydrophilic with Uncoated Tip Polymer with Hydrophilic Less Lubricity More
Silicone
HORNET 14
HORNET 10
FIGHTER
HORNET
Confianza Pro
ConfianzaTM Pro 12
MiracleBros 4.5
MiracleBros 3
MiracleBrosTM 1
MiracleBros 6
PilotTM 200
Highly StenosedLesions
Complex Lesions
Collateral Crossing
Frontline Cases
0
0.5 1.0 1.5 10 14
HORNET 100.008"
HORNET0.008"
SAMURAI0.014"
MARVEL0.014"
SAMURAI RC0.014"
FIGHTER0.009"
HORNET 140.008"
Hydrophilic Polymer with Hydrophilic
SENTAI Guidewire Selection
Boston Scientific values based on bench test data, n = 3, performed by Boston Scientific. Bench test results may not necessarily be indicative of clinical performance. Data on file.
Competitive chart values based on tip load and tip diameter values as reported on competitive websites
Product Order Number (GTIN)
Ref/Catalog No Material Description Tip Shape
Length Quantity per Box
Wor
khor
se G
uide
wire
s SAMURAI™
Guidewire
08714729881216 H749 39302190 2 SAMURAI Guidewire Straight 190 cm 5PK
08714729881230 H749 39302300 2 SAMURAI Guidewire Straight 300 cm 5PK
08714729881223 H749 39302190J 2 SAMURAI Guidewire J-tip 190 cm 5PK
08714729881209 H749 39302300J 2 SAMURAI Guidewire J-tip 300 cm 5PK
MARVEL™
Guidewire
08714729881179 H749 39301190 2 MARVEL Guidewire Straight 190 cm 5PK
08714729881193 H749 39301300 2 MARVEL Guidewire Straight 300 cm 5PK
08714729881186 H749 39301190J 2 MARVEL Guidewire J-tip 190 cm 5PK
08714729881247 H749 39301300J 2 MARVEL Guidewire J-tip 300 cm 5PK
Spec
ialty
Cro
ssin
g Gu
idew
ires
SAMURAI RCGuidewire
08714729886679 H749 39306190 2 SAMURAI RC Guidewire Straight 190 cm 5PK
08714729886686 H749 39306300 2 SAMURAI RC Guidewire Straight 300 cm 5PK
FIGHTER™
Guidewire
08714729886617 H749 39303190 2 FIGHTER Guidewire Straight 190 cm 5PK
08714729886624 H749 39303300 2 FIGHTER Guidewire Straight 300 cm 5PK
HORNET™
Guidewire
08714729886655 H749 9305190 2 HORNET Guidewire Straight 190 cm 5PK
08714729886662 H749 39305300 2 HORNET Guidewire Straight 300 cm 5PK
HORNET 10 Guidewire
08714729886631 H749 39304190 2 HORNET 10 Guidewire Straight 190 cm 5PK
08714729886648 H749 39304300 2 HORNET 10 Guidewire Straight 300 cm 5PK
HORNET 14 Guidewire
08714729886693 H749 39307190 2 HORNET 14 Guidewire Straight 190 cm 5PK
08714729886709 H749 39307300 2 HORNET 14 Guidewire Straight 300 cm 5PK
Exte
nsio
n Gu
idew
ires
STRETCH™
Extension Wire
08714729886716 H749 393080 2 STRETCH Extension Wire N/A 150 cm 5PK
All SENTAI Guidewires are compatible with STRETCH Extension Wire.
All trademarks are property of their respective owners.
FIGHTER, MARVEL, SAMURAI, SAMURAI RC Guidewires, HORNET, HORNET 10, HORNET 14 Guidewires, STRETCH Extension Wire. Intended Use/Indications For Use: Boston Scientific FIGHTER, MARVEL, SAMURAI, SAMURAI RC, HORNET, HORNET 10, and HORNET 14 Guidewires are intended to facilitate the placement of balloon dilatation catheters or other interventional therapeutic devices during percutaneous transluminal coronary angioplasty (PTCA) or other intravascular interventional procedures. These guidewires are not intended for use in the cerebral vasculature. Attachment of the STRETCH Extension Wire to a Boston Scientific extendable guidewire creates an extended guidewire that can be used to exchange out a percutaneous transluminal coronary angioplasty (PTCA) or percutaneous transluminal angioplasty (PTA) catheter without removing the original guidewire from the artery. When the exchange is complete, the STRETCH Extension Wire can be detached and the original guidewire can be used in a conventional manner. Contraindications: None known. Warnings: Guidewires should be used only by physicians thoroughly trained in their intended use. Use extreme caution and careful judgment in patients for whom anticoagulation is not indicated. Severe reaction may occur in response to contrast agents that cannot be adequately premedicated. Excessive force against resistance may result in separation of the guidewire tip, damage to the catheter or vessel damage. Resulting guidewire fractures might require additional percutaneous intervention or surgery. The hydrophilic coating of these guidewires increases the possibility of vessel wall perforation compared to non-hydrophilic coatings. Care should be taken when advancing a guidewire after stent deployment. A guidewire may exit between stent struts when recrossing a stent that is not fully apposed to the vessel wall. Subsequent advancement of any device over the guidewire could cause entanglement between the guidewire and the stent. HORNET 10 and HORNET 14 Guidewires have stiff distal ends. Operate these guidewires carefully so as not to injure the blood vessel, based on information in these instructions. The higher torque performance, stiffer distal end, and/or increased advancement force may present a higher risk of perforation or injury than if using a more flexible guidewire. Precautions: Sharp insertion tools may compromise the integrity of the polymer and/or coating. To avoid guidewire damage and possible shearing of plastic and/or coating, do not withdraw or manipulate the wire through a metal needle cannula. Do not attempt to straighten a wire that has been kinked or bent. Do not advance a kinked guidewire into a balloon catheter, guide catheter, or other interventional device as this may increase the potential of wire breakage. Carefully check and match therapeutic device compatibility to the wire prior to use. Boston Scientific FIGHTER, MARVEL, SAMURAI, and SAMURAI RC Guidewires and Boston Scientific HORNET, HORNET 10, and HORNET 14 Guidewires are designed to be compatible exclusively with the STRETCH Extension Wire for interventional device exchange. Do not use another extension or exchange system. Excessive tightening of the torque device onto the wire may result in abrasion of the coating on the wire. Catheter exchange should only be done under fluoroscopic control. Do not rotate or manipulate the extended guidewire once it is attached. This may cause the extension wire to detach from the wire. Adverse Events: Potential adverse events which may result from the use of the device include but are not limited to: • Drug reactions, including allergic reaction to contrast media • Embolism • Hemorrhage or hematoma, including at the access site • Infection, local infection, systemic infection • Pain at the access site • Pseudoaneurysm • Vascular thrombus • Vessel spasm • Vessel trauma (dissection, perforation, rupture or injury), possibly requiring surgical repair or intervention. In addition, when used for PTCA: • Abrupt closure • Angina or unstable angina • Arrhythmias • Cardiac tamponade/pericardial effusion • Contrast induced renal insufficiency or renal failure • Death • Myocardial infarction or ischemia • Stroke/cerebral vascular accident (CVA)/transient ischemic attack (TIA). Some of the above potential adverse events may require additional surgical intervention. Caution:Federal law (USA) restricts this device to sale by or on the order of a physician. Rx only. Prior to use, please see the complete “Directions for Use” for more information on Indications, Contraindications, Warnings, Precautions, Adverse Events, and Operator’s Instructions.
Rev AA
Interventional Cardiology300 Boston Scientific WayMarlborough, MA 01752-1234www.bostonscientific.com
To order product or for more information contact customer service at 1.888.272.1001.
© 2016 Boston Scientific Corporationor its affiliates. All rights reserved.
IC-400508-AA-US AUG2016