Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
SECTION A-A
SECTION B-B
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
SHEET 1 OF 6
DRAWN
CHECKED
QA
MFG
APPROVED
JF 10/2/2020
DWG NO
TITLE
Cold Box Integration
SIZE
DSCALE
REV
A A
B B
C
E
E
F
PISTON PURGE [DN40 / ¾”]
INJECTOR/COLD TRAPGN2 RETURN [DN25 / ¼”]
INSTRUMENT/SPARE
[DN40 / 1”]
VENT LINE [DN63 / 1 ½”]
SAFETY VALVE [DN63 / 2”]
INJECTORS INLET [DN40 / VJP ½”]
COLD TRAP INLET [DN40 / ½”]
CROSS SHAPE SPOOL PIECE
SPOOL PIECE SUPPORTS (2PL)
13938.8
[548.7
7 in]
INSID
E C
.O.
14600.8
[574.8
3 in]
OVERALL
2599 [102.32 in]
INSIDE C.O.
249.5 [9.82 in]
WARM UP HEATER (700mmX700mmx100mm) (2PL)CLARIFY DESIGN INTENT
3409 [134.21 in]
OVERALL
1506 [
59.2
9 in]
OVER
ALL
696 [27.4 in]
INSIDE C.O.
1.5 [.06 in]
105 [4.13 in]
EXT. DOOR STRUCTURE THICKNESS
3304 [130.08 in]
COLD BOX DEPTH (NO DOOR)
193.8 [7.63 in]
1506 [59.29 in]
630.1
[24.8
1 in]
830.1
[32.6
8 in]
1458.3
[57.4
1 in]
0 [0 in]
811.1 [31.93 in]
1061.1 [41.77 in]
753 [29.65 in]CB q
1026.1 [40.4 in]
0 [
0 in]
530 [20.87 in]
DOOR OPEN
125 [4.92 in]
1652 [
65.0
4 in]C
B q
14600 [
574.8
in]
DO
OR
HT.
1670.7
[65.7
7 in]
1245.9
[49.0
5 in]
NOTE: DIELECTRIC BREAKS REQ.AT EACH CONNECTION.
COLD BOX TO BE ON
CRYOSTAT GROUND
DETAIL C
SECTION E-E
DETAIL D
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
SHEET 2 OF 6
DRAWN
CHECKED
QA
MFG
APPROVED
JF 10/2/2020
DWG NO
TITLE
Cold Box Integration
SIZE
DSCALE
REV
D
I I
146.3 [5.76 in]
APA q TO CE SPOOL q
344.3 [13.56 in]VERTICAL PATCH PANEL
SUPPORT BEAM
52.2 [2.05 in]
(CLEARANCE REQ FROMINSULATION/CE PATCH PANEL?)
952 [
37.4
8 in]
49.5 [1.95 in]
APA SIDE TUBETO INSULATION
660.7 [26.01 in]
CRYO ENVELOPE
444.3 [17.49 in]
CRYO ENVELOPE
CRYOGENIC EQUIP. ENVELOPE
COLD TRAP
SPRAYER MANIFOLD
680 [26.77 in]
PATCH PANELOVERALL
615 [
24.2
1 in]
PATCH
PAN
EL
OVERALL
69.8 [2.75 in]
CLEARANCE REQ?
262.4
[10.3
3 in]
BEAM
HT.
146.6 [5.77 in]
BEAM WIDTH
281 [
11.0
6 in]
600 [23.62 in]
COLD TRAPWIDTH
1693.3 [66.67 in]
19 [.75 in]
99.4 [3.91 in]
MINIMUM?
19 [.75 in] 69.8 [2.75 in]
PD MINI RACK
ELECTRONICS CRATE (2PL)
985.3 [38.79 in]
SECTION J-J
DETAIL K
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
SHEET 3 OF 6
DRAWN
CHECKED
QA
MFG
APPROVED
JF 10/2/2020
DWG NO
TITLE
Cold Box Integration
SIZE
DSCALE
REV
K
PATCH PANEL IN
OPEN POSITION
DETAIL F
DETAIL G
DETAIL H
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
SHEET 4 OF 6
DRAWN
CHECKED
QA
MFG
APPROVED
JF 10/2/2020
DWG NO
TITLE
Cold Box Integration
SIZE
DSCALE
REV
G
H
CLEARANCE REQC-CHANNEL TO INSULATION?
76.2
[3 in]
100 [3.94 in]
88.3 [3.48 in]
SECTION I-I
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
SHEET 5 OF 6
DRAWN
CHECKED
QA
MFG
APPROVED
JF 10/2/2020
DWG NO
TITLE
Cold Box Integration
SIZE
DSCALE
REV
254.1 [10 in]
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
SHEET 6 OF 6
DRAWN
CHECKED
QA
MFG
APPROVED
JF 10/2/2020
DWG NO
TITLE
Cold Box Integration
SIZE
DSCALE
REV
COLD BOX STRUCTURE + INSULATION
COLD BOX STRUCTURE (DOOR)
COLD BOX BEAM / APA TROLLEY
CABLE TRAYS + HARDWARE / PATCH PANELS
CE SPOOL PIECE + ELECTRONICS (2PL)
SPOOL PIECE MOUNTING HARDWARE
CRYOGENICS FEEDTHRUS / PIPES / COLD TRAP / SPRAYER MANIFOLD /NOZZLES / WARMUP HEATER(DESIGN TBD)
APA
PISTON PURGE LINE + MOUNTING HARDWARE
CE BOXES
PIPE FEEDTHRUS (WELDED TO BOX)MINI RACK