NOTES: AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION. ROUTE TANK SENSOR WIRES SO THEY DO NOT PASSOVER SENSORS. USE WIRE TIE MOUNT 155366-01-000 AND WIRE TIE 8343-01-000 AS NEEDED. TANK SURFACE MUST BE CLEANED USING ISOPROPYL ALCOHOL AND PRIMED WITH PRIMER 94. PLACE CROSS LOCATOR ON SENSORS OVER DIMPLES ON TANK. MOUNT ON EXTERIOR SURFACE OF VAN SIDEWALL. 4 CODES/STANDARDS USA CODES/STANDARDS-CSA/CMVSS 265 1B1 1B1 265 SWITCH DETAIL CD SWITCH DETAIL CB SWITCH DETAIL CA WIRE ASM-MAIN TANK 151317-02-000 WIRE ASM-RIGHT 000006514 / 310376-01-000 LPGD 3 1. 2. WIRE ASM-AUX TANK 151316-05-000 3 3 4 TO WATER PUMP 5 WIRES ARE PART OF WIRE ASM-RIGHT. WIRE ASM-RIGHT TO WIRE ASM-CEILING CONNECTION DETAIL DB OUTLET-COAX/12V EXTERIOR 168516-01-CHT SCREW G39-08-16T (2) DETAIL AC GROMMET 016188-10-000 6 6 & 8 PIN HOUSINGS SUPPLIED WITH STEP. DETAIL AC JD ND 7 SEE STEP INSTALLATION FOR ADDITIONAL INFORMATION. SWITCH DETAIL CK SWITCH DETAIL CC TO SHOWER DRAIN LAMP SPEAKER 171547-01-CHT (2) SCREW G39-10-12U (8) 4 3 LED-2 2 RED WIRE ASM-WATER TANK 151317-01-000 BLK 7 WIRES FROM STEP 5 5 5 5 5 KA TC 6 TO STEP CONTROL DETAIL AD RELAY 063912-02-000 SCREW G11-08-12U TO WIRE ASM-CHASSIS 6 SWITCH DETAIL CE 5 GROMMET 016188-10-000 ZZT KD TO DOOR SWITCH DETAIL AA RECEPTACLE-12V 132958-01-000 DETAIL AC SWITCH DETAIL CN SWITCH DETAIL CP MT ZZR ZZS 2 6 1 5 4 8 2 5 1 4 3 6 3 7 DETAIL AD PLATE-WALL 149557-13-CHT SCREW G67-06-08U (2) LAMP ASM-PORCH 184120-01-CHT SCREW G39-06-10U (2) CONNECTOR 58028-01-000 (2) LAMP ASM-PORCH 184120-01-CHT SCREW G39-06-10U (2) CONNECTOR 58028-01-000 (2) RELAY-AWNING 063912-02-000 SCREW G11-08-12U TO LEFT SIDE WIRE ASM-OVHD 167113-01-000 WIRE ASM- COACH DOOR SWITCH (REF) CHASSIS WIRING BUTT SPLICE KD DETAIL AA BLACK/PURPLE DIODE DIODE PORT-SOLAR, SINGLE 191558-01-000 SCREW G39-10-16T (4) DETAIL AF 282 282 SOLAR PANEL - 100 WATT BLK RED PORT-SOLAR HS-1 HT-1 DETAIL AF 282 WIRE ASM- SOLAR SYSTEM 8 YYF JP JA XXZ Ground WATER PUMP CONTROL Load Switch Battery DETAIL AB 8 SEE WIRE ASM-SOLAR SYSTEM AND WIRE ASM-CHASSIS FOR ADDITIONAL INFORMATION. 9 CUT TO LENGTH NEDDED TO FIT POCKET IN TRIM. CONTROL-WATER PUMP 176001-01-000 SCREW 000G11-08-16U DETAIL AB AG VIEW AG PANEL ASM-TRIM,CAB (REF) LIGHT-TAPE,LED,DIFFUSED 190025-26-CHT CHANNEL-LIGHT,TAPE 190097-01-CHT 9 DETAIL AE AM/FM ANTENNA HDMI 190332-02 3 UNSPECIFIED TOLERANCES: MATERIAL: C D 1 TWO-PLACE (X.XX) DSNR: DESCRIPTION: 8 2 B ALL DIMENSIONS ARE IN MILLIMETERS DFTR: 6 A 6 FIRST USED: A REV WHOLE DIM (X) D REF: 8 ITEM/PART NO: 4 WEIGHT: (LBS) SHEET: 7 B 2 4 REFER TO ES0018 FOR FASTENER TIGHTENING GUIDELINES ANGLE 5 5 1 3 COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC. ONE-PLACE (X.X) C 7 WIRING INSTL-BODY,12V 1 OF 5 000179987 / 30072501000 3 1.5 0.50 1 X-X FOR ELECTRICAL CALLOUTS SEE DWG NO. 121339-01-000 FOR ELECTRICAL TORQUE SPECIFICATIONS SEE DWG NO. 128783-01-000 16 259G 05-Oct-2016

8 7 6 5 4 3 1 2 - Winnebago6 6 & 8 pin housings supplied with step. detail ac jd nd 7 see step installation for additional information. switch detail ck switch detail cc to shower

  • Upload
    others

  • View
    20

  • Download
    0

Embed Size (px)

Citation preview

NOTES:

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECUREDPER CODE REQUIREMENTS. USE CLAMP 10495 OR 10497 ORWIRE TIE 8343 OR 108046 AND SCREW G67-XX-XXX ORG56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

ROUTE TANK SENSOR WIRES SO THEY DO NOT PASSOVERSENSORS. USE WIRE TIE MOUNT 155366-01-000 ANDWIRE TIE 8343-01-000 AS NEEDED. TANK SURFACE MUSTBE CLEANED USING ISOPROPYL ALCOHOL AND PRIMED WITHPRIMER 94.

PLACE CROSS LOCATOR ON SENSORS OVER DIMPLES ON TANK.

MOUNT ON EXTERIOR SURFACE OF VAN SIDEWALL.4

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

SWITCHDETAIL CD

SWITCHDETAIL CB

SWITCHDETAIL CA

WIRE ASM-MAIN TANK151317-02-000

WIRE ASM-RIGHT000006514 / 310376-01-000

LPGD

3

1.

2.

WIRE ASM-AUX TANK151316-05-000

3

3

4

TO WATER PUMP

5 WIRES ARE PART OF WIRE ASM-RIGHT.

WIRE ASM-RIGHTTO WIRE ASM-CEILINGCONNECTIONDETAIL DB

OUTLET-COAX/12VEXTERIOR168516-01-CHTSCREWG39-08-16T (2)DETAIL AC

GROMMET016188-10-000

6 6 & 8 PIN HOUSINGS SUPPLIED WITH STEP.

DETAIL AC

JD ND

7 SEE STEP INSTALLATION FOR ADDITIONAL INFORMATION.

SWITCHDETAIL CK

SWITCHDETAIL CC

TO SHOWERDRAIN LAMP

SPEAKER171547-01-CHT (2)SCREWG39-10-12U (8)

4

3

LED-22

RED

WIRE ASM-WATER TANK151317-01-000

BLK

7

WIRESFROM STEP

5

55

5

5

KATC

6

TO STEPCONTROLDETAIL ADRELAY063912-02-000SCREWG11-08-12U

TO WIREASM-CHASSIS

6

SWITCHDETAIL CE

5

GROMMET016188-10-000

ZZT

KDTO DOOR SWITCHDETAIL AA

RECEPTACLE-12V132958-01-000DETAIL AC

SWITCHDETAIL CN

SWITCHDETAIL CP

MTZZR

ZZS

2

6

1

5

4

8

2

5

1

4

3

6

3

7

DETAIL AD

PLATE-WALL149557-13-CHTSCREWG67-06-08U (2)

LAMP ASM-PORCH184120-01-CHTSCREWG39-06-10U (2)CONNECTOR58028-01-000 (2)

LAMP ASM-PORCH184120-01-CHTSCREWG39-06-10U (2)CONNECTOR58028-01-000 (2)

RELAY-AWNING063912-02-000SCREWG11-08-12U

TO LEFT SIDE

WIRE ASM-OVHD167113-01-000

WIRE ASM-COACHDOOR SWITCH

(REF)

CHASSIS WIRING

BUTT SPLICEKD

DETAIL AABLACK/PURPLE

DIODE

DIODE

PORT-SOLAR, SINGLE191558-01-000SCREWG39-10-16T (4)DETAIL AF

282

282 SOLAR PANEL - 100 WATT

BLK

RED

PORT-SOLAR

HS-1

HT-1

DETAIL AF 282

WIRE ASM-SOLAR

SYSTEM8

YYF

JPJA

XXZ

Gro

und

WATER PUMP CONTROL

Loa

d

Sw

itch

Ba

ttery

DETAIL AB

8 SEE WIRE ASM-SOLAR SYSTEM AND WIRE ASM-CHASSIS FORADDITIONAL INFORMATION.

9 CUT TO LENGTH NEDDED TO FIT POCKET IN TRIM.

CONTROL-WATER PUMP176001-01-000SCREW000G11-08-16UDETAIL AB

AG

VIEW AG

PANEL ASM-TRIM,CAB(REF)

LIGHT-TAPE,LED,DIFFUSED190025-26-CHTCHANNEL-LIGHT,TAPE190097-01-CHT

9

DETAIL AE

AM/FMANTENNA HDMI

190332-02

3

UNSPECIFIED TOLERANCES: MATERIAL:

C

D

1

TWO-PLACE (X.XX)

DSNR:

DESCRIPTION:

8

2

B

ALL DIMENSIONS ARE IN MILLIMETERSDFTR:

6

A

6

FIRST USED:

A

REV

WHOLE DIM (X)

D

REF:

8

ITEM/PART NO:

4

WEIGHT: (LBS)

SHEET:

7

B

2

4

REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES

ANGLE

5

5

13

COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC.

ONE-PLACE (X.X)

C

7

WIRING INSTL-BODY,12V

1 OF 5 000179987 / 30072501000

3

1.5

0.50

1

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

16 259G

05-Oct-2016

NOTES:

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECUREDPER CODE REQUIREMENTS. USE CLAMP 10495 OR 10497 ORWIRE TIE 8343 OR 108046 AND SCREW G67-XX-XXX ORG56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

SPEAKER160868-01-CHT (2)GRILL160868-02-CHT (2)SCREWG11-08-08U (8)

SWITCHDETAIL CH

TV-24",FLAT PANEL DLED,HDTV000031269 / 316937-01-000CORD-POWER,12VDC191991-01-000ADAPTOR-COAX 90176986-01-000BRACKET ASM-MNT,TV000182062 / 302673-01-XXXSCREW0MG02U-04-012 (4)WASHER0ME02U-04-071 (4)SCREWG11-10-10U (4)DETAIL BA

SWITCHDETAIL CG

WALLPLATE179004-02-CHTDETAIL BB

1.

TO FURNACE

TO REFRIGERATORDETAIL BC

TO HEATER

TV - MAIN68Y

WIRE ASM-LEFT000020128 / 31399201000

DETAIL BC

EU

ET

NE

JE

REFRIGERATOR12V CONNECTIONPLATES(REF)

2 COAX IS PART OF WIRE ASM-LEFT.

COAX(UNMARKED)

COAX(BLU)

COAX(RED)

TO TV

FROMCABLEINPUT

FROM ROOFANTENNA

6

22

DETAIL BB

ANTENNACABLE

SET

LED-22

SWITCHDETAIL CJ

DETAIL BA

2

CABLE-RCA,3-WAY

OUT

IN

OUT

SPLITTER086756-02-000

TO EXTJACK

COAX(YEL)2

COAX(BRN)

COAX(GRN)

PANEL-MONITOR175724-06-000SCREWG11-08-08U (4)

SUBWOOFER124884-01-000GRILL151844-01-CHTSCREWG11-08-12U (4)

CROSSOVER BOX150140-01-000CROSSOVER COIL150140-02-000CLAMP10497-02-000SCREWG11-08-08U (4)SCREWG67-10-12B

255

STEREO-AM/FM/DVDWALLMOUNT190332-02-000SCREW76790-03-000 (4)DETAIL AE

CONVERTER-45 AMP184353-01-000SCREWG67-10-12U (3)DETAIL CL

PLATE-WALL,COAX EXTERIOR183638-01-CHTSCREWG39-08-12U (3)

TO WATER TANK

OUT

TO COAXPLATE

(GALLEY)

2COAX(GRN)

JC,NCTO WIRE ASM-DOOR

DC

SEE WIRING INSTL-CHASSIS FOR ADDITIONAL INFORMATION.3

3TDTO TRAILERLIGHT CONTROL

HT(8 GA GRN)

HS(8 GA BLK)

HS-1(10 GA BLK/YEL)

HT-1(10 GA GRN/WHT)

DETAIL BD 4

4 SEE WIRE ASM-SOLAR SYSTEM & WIRE ASM-CHASSIS FORADDITIONAL INFORMATION.

5 SEE HEATER INSTALLATION INSTRUCTIONS FOR ADDITIONALINFORMATION.

USB-CHARGER188312-01-000DETAIL AC

USB-CHARGER188312-01-000DETAIL AC

CONTROL-CHARGE,SOLAR191278-01-000SCREWG11-08-12U (2)DETAIL BD

PANEL-EMS174295-07-000SCREWG11-08-08U (4)

CONTROL-HTR192038-32-CHTSCREWG11-08-08U (4)FUSE062901-09-000

PLATE-WALL167733-01-CHT

282

DISTRIBUTION PANEL187831-01-CHTSCREWG11-08-12U (4)DETAIL CM

5

282 SOLAR PANEL - 100 WATT

CABLE-HDMI

68Y

SENSOR-TEMP192038-35-CHTPLATE-TEMP SENSOR192254-01-CHTSCREWG11-08-08U (2)

SEE SHEET 4 FOR ADDITIONAL INFORMATION.6

RADIO/AM/FM/CD/DVD PLAYER255

DCPOWER

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,12V

000179987 / 30072501000 2 OF 5

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

ANT/CABLE INDC IN(12V)

NS-24D510NA1724" INSIGNIA

L-AUDIO-R

AUDIOOUT

USB

HDMI2

HDMI1(ARC)

AV IN

VIDEO

DIGITALOUTPUT

(COAXIAL)

05-Oct-2016

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)

DETAIL CD

XXJC

TV SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-45-CHTSCREWG11-08-08U (2)

DETAIL CG

JFEX

SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)

DETAIL CJ

JCXU

NOTES:

2

DETAIL CL

CONVERTER(REF)

DETAIL CM(BACK SIDE)

1

M

DETAIL CM

U

CIRCUIT FROM WIRE ASM-COACH.

CIRCUIT FROM WIRE ASM-CHASSIS

1

1

L

2

DETAIL CN

PLATE-SWITCH144363-02-CHTSWITCH-ROCKER108357-14-000ACTUATOR-SWITCH108356-10-CHTSCREWG11-06-10U (2)

DETAIL CK

SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-59-CHTSCREWG11-08-08U (2)

PLATE-SWITCH164352-06-CHTSCREWG11-06-10U (2)

DETAIL CH

SWITCH-ROCKER108357-18-000ACTUATOR-SWITCH108356-19-CHTWIRE ASM-THERM186796-01-000

WB

SWITCH-ROCKER108357-07-000ACTUATOR-SWITCH108356-29-CHT

DETAIL CE

KKD

PLATE-SWITCH158431-17-CHTSCREWG11-06-10U (4)

DETAIL CB

SWITCH-ROCKER108357-14-000ACTUATOR-SWITCH108356-28-CHTSWITCH-BLANK096241-03-000

SWITCH-ROCKER108357-06-000ACTUATOR-SWITCH108356-12-CHT

L.P.

VALVE

SWITCH-ROCKER108357-09-000ACTUATOR-SWITCH108356-27-CHTSWITCH-ROCKER

108357-21-000ACTUATOR-SWITCH108356-23-CHT PLATE-SWITCH

158431-17-CHTSCREWG11-06-10U (4)

DETAIL CA

SWITCH-ROCKER135740-01-CHT (3)SWITCH-BASE135741-03-CHTSWITCH-BEZEL135742-03-CHTSCREWG11-08-08U (4)

DETAIL CC

JCPE

JCPC

JCA

SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)

DETAIL CP

FLJC

35L LADDER W/LUGGAGE RACK

WITHOUT3 35L

35L

3

SWITCH-ROCKER135740-01-CHT (2)135740-04-CHTSWITCH-BASE135741-03-CHTSWITCH-BEZEL135742-03-CHTSCREWG11-08-08U (4)WIRE ASM-RESISTOR140195-01-000

JCRRA-1

PLJC

PJJC

RRA

15

A FUSE MAX

3

12

12V RCP

10

VENT

8

DETAIL CM(BACK SIDEOF COVER)

LIGHTS

10A FUSE MAX

A FUSE MAX

A FUSE MAX

A FUSE MAX

15A FUSE MAX

14

15

LP DETECTOR

11

9

15

5

15

A FUSE MAX

A FUSE MAX

15

3

A FUSE MAX

A FUSE MAX

HEATER

18

TV/RADIO13

1

REFRIG

4

AWNING

A FUSE MAX

16

A FUSE MAX A FUSE MAX

15

WATERPUMP

5

A FUSE MAX

17

A FUSE MAX

REFRIG

A FUSE MAX

7

2

A FUSE MAX

A FUSE MAX

6

15

DETAIL CM(COVER REMOVED)

MACERATOR

20

1

2

JE10 Y(REFRIGERATOR)

JF14 Y(TV/RADIO)

M

JD14 Y(12V RCP)

J ET16 Y(REFRIG)

NM12 Y(AWNING)

JC14 Y(LIGHTS)

JB10 Y(HEATER)

JG14 Y(VENT)

JA12 Y(WATER PUMP)

WB16 Y(LP DETECTOR)

FUSE-15 AMP062901-05-000 (7)

FUSE-10 AMP062901-04-000

FUSE-5 AMP062901-02-000

CIRCUIT BREAKER184387-01-000

FFZ10 Y(MACERATOR)

FUSE-3 AMP062901-01-000

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,12V

000179987 / 30072501000 3 OF 5

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

OUT

AWNING

IN

SHOWERDRAIN

WATERPUMP

54

21

10

918

14

711

17

83

613

12

15

16

15

15

15

15

15

15

15

3

5

1020 AMP

05-Oct-2016

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

NOTES:

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECUREDPER CODE REQUIREMENTS. USE CLAMP 10495 OR 10497 ORWIRE TIE 8343 OR 108046 AND SCREW G67-XX-XXX ORG56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

MOUNTED ON EXTERIOR SURFACE OF ROOF.

MOUNTED ON INTERIOR SURFACE OF ROOF.

2

3

LSH-2

CHANNEL-HAT166770-01-CHT (6)TAPE-DOUBLE SIDE76322-25-000(12-75 MM)

1.

2

3

3ANTENNA-RADIO90944-01-000

TO BATHVENT

TO EXTERIORLAMP

WIRE ASM-ROOF000024585 / 315044-01-000

TO GALLEYVENT

LED-26

ANT-8

TO WIRE ASM-RIGHTDETAIL DB

WIRE ASM-CEILING LIGHTS192177-01-000

CABLE ASM-COAX(BLU)

CABLE ASM-COAX(BLU)

ADAPTER82134-01-000 (3)

DETAIL DA

CABLE ASM-COAX(YEL)

CABLE ASM-COAX(YEL)

WIRE ASM-ROOFWIRE ASM-LEFT

WIRE ASM-ROOFWIRE ASM-LEFT

GROMMET-EDGE LINER114208-03-000

TO SPEAKER

TO SPEAKER

TO WIRE ASM-LEFTDETAIL DA

WIRE ASM-RIGHT WIRE ASM-ROOF

DETAIL DB

ADAPTER82134-01-000 (2)

CABLE ASM-COAX(YEL)

CABLE ASM-COAX(YEL)

TO AWNINGDETAIL DD

GROMMET114208-04-000

CABLE ASM-COAX(GRN)

CABLE ASM-COAX(GRN)

WIRE ASM-LEFT WIRE ASM-ROOF

WIRE ASM-RIGHT WIRE ASM-ROOF

CABLE ASM-COAX(GRN)

CABLE ASM-COAX(GRN)

PANEL-SUPPORT166713-06-CHTSCREWG39-08-12U (6)SCREWG39-08-10U (6)

READ-62

WIRE ASM-DOOR187458-01-000

VIEW DC

ROUTE WIRE ASMTHROUGH WIRETRACK IN DOOR

JC,NCTO WIRE ASM-LEFT

4 WITHOUT35L LADDER W/LUGGAGE RACK

35L

SPLICE CIRCUITS SSY AND PM TOGETHER.5

CIRCUITS ZZK AND NC NOT USED. SECURE TO HARNESS.6

DETAIL DD(CAREFREE)

DETAIL DD(FIAMMA)

4

5

6

35L

WIRE ASM-ROOFAWNING

WIRE ASM-ROOFAWNING

PM

ZZK

FFN

SSY NC

FFR

RED

BLACK

BLUE

BROWN

BLACK(LIMIT SWITCH)

RED(LIMIT SWITCH)

BLUE(MOTOR)

RED(MOTOR)

FFN

FFR

SSY

PM

PANEL-SOLAR 100 WATT191276-01-CHTBRACKET-MTG,SOLAR191837-01-CHT (4)BOLTC26-05-12U (4)NUTD39-05-00U (4)SCREWG39-10-10U (8)

282 SOLAR PANEL - 100 WATT

282 2

PORT-SOLAR, 3 POS191277-01-CHTSPACER166672-11-CHT (2)166672-21-CHTSCREWG39-10-10U (5)G39-10-16U (3)GROMMET114208-04-000DETAIL DE

282

WIRE ASM-ROOF PORT-SOLAR

(REF)

8 GRN TO GROUND STUD(STACK GROUND WIRES)

8 BLK TO EMPTYPOST ON30A BREAKER

DETAIL DE 282

ADJUST ROOF RAILS AND KAYAK CARRIERS SO THAT THEYARE NOT DIRECTLY OVER THE SOLAR PANEL.

7

DETAIL EA

7

2

CABLE ASM-COAX087105-02-015(BLU)

8

ROUTE CABLE TO ANTENNA PLATE IN OVHD CABINET.8

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,12V

000179987 / 30072501000 4 OF 5

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

05-Oct-2016

NOTES:

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECUREDPER CODE REQUIREMENTS. USE CLAMP 10495 OR 10497 ORWIRE TIE 8343 OR 108046 AND SCREW G67-XX-XXX ORG56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

ADJUST ROOF RAILS AND KAYAK CARRIERS SO THAT THEYARE NOT DIRECTLY OVER THE SOLAR PANEL.

2

1.

2DETAIL EA

(2)361

72

1005

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,12V

000179987 / 30072501000 5 OF 5

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

05-Oct-2016