Table of Contents Definitions 2

General Information 2

Lots and Grounds 3

Roof 4

Exterior 6

Electrical 7

Garage 8

Structure 8

Attic 9

Basement 9

Air Conditioning 10

Heating System 11

Plumbing 12

Bathroom 12

Kitchen 13

Bedroom 13

Living Space 14

Laundry Room/Area 14

Summary 16

A1 Home Inspections, LLC 1 of 18 12/28/2018 02:23 PM A1HomeInspectionSampleReport.inspx

Prepared for: John Client

New Castle, Pa 16101

A1 Home Inspections Pa, LLC & A1 Home Inspections Ohio, LLC

Palm-Tech Inspector, Copyright 1998-2018, PDmB, Inc.

DefinitionsNOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection

A Acceptable Functional with no obvious signs of defect. NP Not Present Item not present or not found. NI Not Inspected Item was unable to be inspected for safety reasons or due to lack of power, inaccessible, or disconnected at time of

inspection. M Marginal Item is not fully functional and requires repair or servicing. D Defective Item needs immediate repair or replacement. It is unable to perform its intended function.

General InformationProperty Information

Property Address 000 SomeRoad Way City New Castle State Pa Zip 16101 Contact Name Realtor or Owner Name Phone 540-376-1140 Email hkkul@hotmail.com

Client Information

Client Name John Client Client Address 000 SomeRoad Way City New Castle State Pa Zip 16101 Phone 540-376-1140 Email hkkul@hotmail.com

Inspection Company

Inspector Name John Kulnis Company Name A1 Home Inspections, LLC Address 1916 Brigadoon Ln City New Castle State Pa Zip 16101 Phone 540-376-1140 Email a1homeinsp@outlook.com Amount Received 285.00

Conditions

Others Present Buyer's Agent and Buyer Property Occupied Occupied Estimated Age 62 Entrance Faces South Inspection Date 12/24/2018 Start Time 2pm End Time 4pm Electric On Yes No Not Applicable Gas/Oil On Yes No Not Applicable Water On Yes No Not Applicable

CO Test Result Reading of 2 on the meter. 0-1 PPM Normal Levels, up to 9 PPM Standard for living areas. Informational purposes only. Recommend having a retest by a licensed CO contractor

Temperature 55 Weather Snow Soil Conditions Wet

A1 Home Inspections, LLC 2 of 18 12/28/2018 02:23 PM A1HomeInspectionSampleReport.inspx

Prepared for: John Client

New Castle, Pa 16101

A1 Home Inspections Pa, LLC & A1 Home Inspections Ohio, LLC

Palm-Tech Inspector, Copyright 1998-2018, PDmB, Inc.

General Information (Continued)Space Below Grade Basement Building Type Single family Garage Attached Water Source City How Verified Visual Inspection Sewage Disposal City How Verified Owner Additions/Modifications None Permits Obtained N/A How Verified Not verified per agreement

Lots and GroundsThis inspection is not intended to address or include any geological conditions or site stability information. For information concerning these conditions, a geologist or soils engineer should be consulted. Any reference to grade is limited to only areas around the exterior of the exposed foundation or exterior walls. This inspection is visual in nature and does not attempt to determine drainage performance of the site or the condition of any underground piping, including municipal water and sewer service piping or septic systems. When decks and porches are built close to the ground where no viewing or access is possible, we cannot make accurate opinions. These areas as well as others that are too low to enter, or in some other manner not accessible, are excluded from the inspection and are not addressed in this report. We routinely recommend that inquiry be made with the seller about knowledge of conditions. To alleviate water from penetrating into the foundation, walkways and other home components, the grading should slope 6 inches down to at least 10ft away from the home. Shrubs and other foliage be kept at least 1 ft away from the structure. There should be at least 8" of clearance between the soil and framework of the home. Snow cover will limit the exterior inspection, therefore we are not liable for defects not visible do to snow cover.

A NP NI M D

1. Driveway: Asphalt - Small normal cracking over drainage pipe. Monitor for further cracking or refer to a licensed contractor for repair.

2. Walks: Paver, Stone

3. Steps/Stoops: Composite decking 4. Porch: Composite decking 5. Patio: Composite decking

A1 Home Inspections, LLC 3 of 18 12/28/2018 02:23 PM A1HomeInspectionSampleReport.inspx

Prepared for: John Client

New Castle, Pa 16101

A1 Home Inspections Pa, LLC & A1 Home Inspections Ohio, LLC

Palm-Tech Inspector, Copyright 1998-2018, PDmB, Inc.

Lots and Grounds (Continued)Patio: (continued)

6. Deck: Composite 7. Grading: Minor slope 8. Swale: Pooling due to improper drainage - Recommend improvements be made to the grade,

swale slope and depth to improve water control, Swale does not have adequate depth or slope for proper drainage, No swale present, water pooling due to flat grade and lack of swale

9. Vegetation: Shrubs 10. Window Wells: Appear to be functioning. No water intrusion observed on interior walls. 11. Exterior Surface Drain: Surface drain

RoofThe Standards of Practice does not required the Inspector to go on the roof. It is at the sole discretion of the Inspector to walk the roof. A roof rating given from a ground inspection is for defects that could only be seen from the ground that are readily visible. Only the property owner would have accurate knowledge of this information. Please refer to the seller's disclosure in reference to the roof system's age, condition, prior problems, etc. The roof's age cannot be determined by the inspector. This inspection is not a warranty against future roof leaks. Even a roof that appears to be in good, functional condition may leak under certain circumstances. Inspector does not take responsibility for a roof leak that happens in the future. Roof leaks can occur at anytime during the homes existence. The age of the roof also does not guarantee it from leaking. Shingles are not lifted to inspect nailing patterns and in lifting the shingle, this breaks the seal of the shingle. Budget for a new roof and possible replacement of the underlying wood. Please note that there may be defects on the interior that are not apparent at the time of inspection. It is HIGHLY recommended that you hire a qualified chimney professional to clean, run a camera throughout the flue and components and to further evaluate for latent defects. We will not be responsible for defects found after the date of this report.

A NP NI M D

Main Roof Surface 1. Method of Inspection: On roof 2. Unable to Inspect: 100% 3. Material: Asphalt shingle - Loose or damaged shingles, Roof near end of useful life, Roof shows

signs of deterioration, Roofing nails were observed to be backing out of and popping through the shingle tabs., Shingles not sealing, Signs of cracking

4. Type: Gable 5. Approximate Age: 20

A1 Home Inspections, LLC 4 of 18 12/28/2018 02:23 PM A1HomeInspectionSampleReport.inspx

Prepared for: John Client

New Castle, Pa 16101

A1 Home Inspections Pa, LLC & A1 Home Inspections Ohio, LLC

Palm-Tech Inspector, Copyright 1998-2018, PDmB, Inc.

Roof (Continued)6. Flashing: Aluminum

7. Plumbing Vents: Cast Iron 8. Electrical Mast: Mast with tie back at roof

9. Gutters: Aluminum - Gutters have negative flow and are holding water, Leaking, Recommend further evaluation by a qualified contractor

10. Downspouts: Aluminum 11. Leader/Extension: Empty into underground piping West Chimney 12. Chimney: Brick - Chimney requires tuck point repairs

13. Flue/Flue Cap: Clay 14. Chimney Flashing: Galvanized - Improper installation- counter flashing is not recessed into mortar

joints- requires corrections, Recommend further evaluation by a qualified roofing contractor.

A1 Home Inspections, LLC 5 of 18 12/28/2018 02:23 PM A1HomeInspectionSampleReport.inspx

Prepared for: John Client

New Castle, Pa 16101

A1 Home Inspections Pa, LLC & A1 Home Inspections Ohio, LLC

Palm-Tech Inspector, Copyright 1998-2018, PDmB, Inc.

ExteriorInspection of the exterior components is limited to obvious defects at the surface. There may be latent underlying defects to the interior caused by defects on the exterior such as age, installation and product defects that may not be readily accessible during the inspection. Brick veneer siding is required to have weep holes installed at the window, door frames and above soil grade line. Insufficient or lack of weep holes is common. This is a defect and defects may exist behind the brick veneer which are not readily visible for inspection. According to the National Electric Code, outdoor receptacles must be GFCI protected. Recommend GFCI receptacles be installed by a qualified electrician.

A NP NI M D

North Exterior Surface 1. Type: Brick veneer - Cracks observed at mortar/brick exterior wall. No deflection of wall was visible

at time of inspection. Significant cracks need attention due to possible problems with wall and foundation settlement. All buildings settle with minor wall and foundation cracking visible at some point. Recommend sealing cracks to prevent moisture intrusion and additional ice damage, monitoring for further movement. Should the cracks enlarge beyond their current size, ha