4
If you need to run the pump outside a batch, simply switch Constantand then press Run”. The system will operate the pump at a speed youve pre-set. SELF-CONTAINEDEverything you need to run a solenoid-controlled AODD pump is in this system except the air. It monitors, cal- culates, supplies and switches power. All you need to do is determine the number of strokes, the number of batches and the interval between them and the system takes over. No me or setup expenses are need to get opmal results. Even the internal circuit-breaker for the solenoid output is self- reseng. If you need to talk to somebody about a technical maer, we understand both electronics/instrumentaon and pumps/piping. SAFETYThe system operates the pump using low voltage and is designed to be failsafe in eve- ry likely scenario. The external control design permits the addi- on of panic buons and automac shutoffs as well. The output to the solenoid is even circuit– breaker protected. NNNNo Nerds Needed. Anybody can program and run this system. Its interface is very intuive and its operaon is simplicity itself. If youve pro- grammed an FCSII, you already know how to pro- gram the 72000-00 Pump Batch Controller. If you need to operate a solenoid-controlled pump to do batching, this system is the solution. AT LAST…. A controller designed to accurately, simply and economically operate solenoid-controlled AODD pumps in a Batching Mode. The 72000-00 Pump Batch Controller has all the features youve been looking for in one compact unit. SIMPLICITY.. All variables are set using the external keypad and there are no mul- ple-screens to deal with. The keypad is always availa- ble for selecon of any of the three batchesavailable or the Constant Runmode as well as programming system values. The unit provides the 12 volts DC needed to oper- ate the pump from the con- trollers internal power sup- ply. SMART DESIGN.. The pump speed is variable over any value in the range of 0.1 to 3600 Seconds/Stroke. The user determines the number of strokes in a batch, the number of batches in a pro- gram and the me interval between batches. Its intui- vely easy to use and easy to dial into the right val- ues. The NEMA 4X enclosure can be mounted with hand tools and the unit is available in two versions, 120 volts AC or 220-240 volts AC. VERSATILE.. The unit can be paused or stopped re- motely. External Killswitches can be included for safety. JOGThere are mes when you might need to oper- ate the pump outside the Batchmode. Maybe to prime the pump or to purge it or to top off a batch PUMP BATCH CONTROLLER 72000-00

72000 00 PUMP BATCH CONTROLLER

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 72000 00 PUMP BATCH CONTROLLER

If you need to run the pump outside a batch, simply switch “Constant’ and then press “Run”. The system will operate the pump at a speed you’ve pre-set.

SELF-CONTAINED… Everything you need to run a solenoid-controlled AODD pump is in this system

except the air. It monitors, cal-culates, supplies and switches power. All you need to do is determine the number of strokes, the number of batches and the interval between them and the system takes over. No time or setup expenses are need to get optimal results. Even the internal circuit-breaker for the solenoid output is self-resetting. If you need to talk to somebody about a technical matter, we understand both electronics/instrumentation and pumps/piping.

SAFETY… The system operates the pump using low voltage and is designed to be failsafe in eve-ry likely scenario. The external control design permits the addi-

tion of panic buttons and automatic shutoffs as well. The output to the solenoid is even circuit–breaker protected.

NNN… No Nerds Needed. Anybody can program and run this system. Its interface is very intuitive and its operation is simplicity itself. If you’ve pro-grammed an FCSII, you already know how to pro-gram the 72000-00 Pump Batch Controller. If you need to operate a solenoid-controlled pump to do batching, this system is the solution.

AT LAST…. A controller designed to accurately, simply and economically operate solenoid-controlled AODD pumps in a Batching Mode. The 72000-00 Pump Batch Controller has all the features you’ve been lookingfor in one compact unit.

SIMPLICITY.. All variables are set using the external keypad and there are no mul-tiple-screens to deal with. The keypad is always availa-ble for selection of any of the three “batches” available or the “Constant Run” mode as well as programming system values. The unit provides the 12 volts DC needed to oper-ate the pump from the con-troller’s internal power sup-ply.

SMART DESIGN.. The pump speed is variable over any value in the range of 0.1 to 3600 Seconds/Stroke. The user determines the number of strokes in a batch, the number of batches in a pro-gram and the time interval between batches. It’s intui-tively easy to use and easy to “dial in” to the right val-ues. The NEMA 4X enclosure can be mounted with hand tools and the unit is available in two versions, 120 volts AC or 220-240 volts AC.

VERSATILE.. The unit can be paused or stopped re-motely. External “Kill” switches can be included for safety.

JOG… There are times when you might need to oper-ate the pump outside the “Batch” mode. Maybe to prime the pump or to purge it or to top off a batch

PUMP BATCH CONTROLLER 72000-00

sharris
Highlight
Page 2: 72000 00 PUMP BATCH CONTROLLER

DIMENSIONS: 6-3/4” H x 4-3/4” W X 2-1/4” D

ENCLOSURE CONSTRUCTION: NEMA 4X with sealing gland for cable and boot for switch

WEIGHT: 1-1/2 Pounds

POWER CONSUMPTION: 12 Watts

VOLTAGE REQUIREMENTS: 120 VAC

VOLTAGE OUPUT (TO SOLENOID): 12 VDC 750 ma MAXIMUM The Pump Solenoid must operate on 12 volts DC.

OPERATING TEMPERATURE RANGE: 40F to 100F

SPEED RANGE: 0.1 to 3600 Seconds/Stroke

NUMBER OF BATCHES: Three totally separate settings plus a “Constant Run” preset.

We will be happy to address any technical questions you may have. Please ask your local distributor and we’ll

Page 3: 72000 00 PUMP BATCH CONTROLLER

JOG… There are times when you might need to operate the pump without the current loop. May-be the loop is down due to a sensor failure or there is a situation that isn’t covered by the set-up. If you need to run the pump without the loop, simply switch to JOG. The system will oper-ate the pump at the midpoint speed value of your two settings.

SELF-CONTAINED...Everything you need to run a pump is in this sys-tem except the air. It monitors, calculates, supplies and switches power. All you need to do, is de-termine how you want the pump to respond to a signal and the sys-tem takes over. No time or setup expenses are need to get optimal results. Even the internal circuit-breaker for the solenoid output is self-resetting. If you need to talk to somebody about a technical matter, we understand both elec-tronics/instrumentation and pumps/piping.

SAFETY… The system operates the pump using low voltage and is de-signed to be failsafe in every likely scenario. Loop outages, sensor

failures and wire-breaks all result in the pump stopping. The external control design permits the addition of panic buttons and automatic shutoffs as well. The output to the solenoid is even circuit–breaker protected.

NNN… No Nerds Needed. Anybody can program and run this system. Its interface is very intuitive and its operation is simplicity itself. If you need to operate solenoid-controlled AODD pumps with a 4-20 ma. signal, this system is the solution.

AT LAST…. A controller designed to accurately, simply and economically operate solenoid-controlled AODD pumps utilizing a 4-20 ma. loop to set pump speed. The 72100-00 Pump Controller has all the featuresyou’ve been looking for in one compact unit.

SIMPLICITY...All variables are set using the internal 5-key touchpad and there are no multiple-screens to deal with. The keypad is safe-ly away from unauthorized users. The unit provides 12 volts DC from its internal power supply to operate the pump. The system panel has one sealed switch on it; to RUN, STOP or JOG the pump. The loop milliamps and the pump speed and condition (Run/Stop/Jog) are all contin-uously displayed.

SMART DESIGN...The pump speed is variable over any value in the range of 0 to 499 Strokes/Minute. This means it’s easy to calculate the volu-metric output of the pump in standard engineering units and that the internal calcula-tions by the controller are linearly proportional to the loop current across the entire range of values. It’s intuitively easy to use this way and easy to “dial in” to the right values. The NE-MA 4X enclosure can be mounted with hand tools and the unit is powered by 120 volts AC.

VERSATILE...The unit can be controlled remotely. A simple switch or relay can provide the contact clo-sures the unit needs to Run/Stop/Jog. It only takes three wires and they connect to a terminal strip on the circuit board. Any loop current can be the low value and any current above 10 ma. can be the high value. The low value can be equivalent to the slow-est or fastest pump speed as can the high current val-ue. This makes the system compatible with an enor-mous variety of sensors and signals.

PUMP CONTROLLER72100-00

sharris
Highlight
Page 4: 72000 00 PUMP BATCH CONTROLLER

DIMENSIONS: 6-3/4” H x 4-3/4” W X 2-1/4” D

ENCLOSURE CONSTRUCTION: NEMA 4X with sealing gland for cable and boot for switch

WEIGHT: 1-1/2 Pounds

POWER CONSUMPTION: 12 Watts

VOLTAGE REQUIREMENTS: 120 VAC

VOLTAGE OUPUT (TO SOLENOID): 12 VDC 750 ma MAXIMUM

OPERATING TEMPERATURE RANGE: 40F to 100F

SPEED RANGE: 0 TO 499 Strokes/ Minute

We will be happy to address any technical questions you may have. Please ask your local distributor and we’ll see to it that you quickly receive the information.