® U.S. Registered Trademark. Patents pending. Copyright © 2013 Honeywell International Inc.
All rights reserved.
Installation Guide
PRO TH2000DV/TH1000DV SeriesThermostats
This manual covers the following models• TH1100DV:ForHeatonlysystems• TH2110DV/TH1110DV:For1Heat/1Coolsystems• TH2210DV/TH1210DV:For2Heat/1Coolheatpumpsystemsonly
(Pullthermostatfromwallplateandturnovertofindmodelnumber.)
System TypesTH2110DV/TH1110DV:• Gas,oil,orelectricheatwithair
conditioning
• Warmair,hotwater,high-efficiencyfurnaces,1Heat/1Coolheatpumps,steam,gravity
• Heatonly
• Heatonlywithfan
• Coolonly
• 750mVheatingsystems
TH2210DV/TH1210DV:• 2Heat/1Coolheatpumps
TH1100DV:• Gas,oil,orelectricheat
• Warmair,hotwater,steam,gravity
• Heatonly
• 750mVheatingsystems
Must be installed by a trained, experienced technicianReadtheseinstructionscarefully.Failuretofollowtheseinstructions
candamagetheproductorcauseahazardouscondition.
Need Help?Forassistancewiththisproductpleasevisithttp://customer.honeywell.com
orcallHoneywellCustomerCaretoll-freeat1-800-468-1502
69-2800EFS-01
Installation Guide
269-2800EFS—01
C IS OPTIONAL WITH BATTERIES
NOTUSED
R
C
AUX/E
Y
G
O
B
M34682
Wallplateinstallation
Removethewallplatefromthethermostatasshownatleft,thenfollowdirectionsbelowformounting.
1. Pullwiresthroughwirehole.
2. Positionwallplateonwall,levelandmarkholepositions with pencil.
3. Drillholesatmarkedpositionsasshownbelow,thentapinsuppliedwallanchors.
4. Placewallplateoveranchors,insertandtightenmountingscrews.
Pullatbottomtoremovethermostatfromwallplate.
CAUTION: ELECTRICAL HAZARDCancauseelectricalshockorequipmentdamage.Disconnectpowerbeforebeginninginstallation.
Drill3/16"holesfordrywall.Drill7/32"holesforplaster.
MERCURY NOTICEIfthisproductisreplacingacontrolthatcontainsmercuryinasealedtube,donotplacethe old control in the trash. Contact the Thermostat Recycling Corporation at www.thermostat-recycle.orgor800-238-8192forinformationonhowandwheretoproperlyandsafelydisposeofyouroldthermostat.
M34683
Wallanchors
Mountingscrews
Wirehole
PRO TH2000DV/TH1000DV Series
3 69-2800EFS—01
Power options
TH2110DV/TH1110DV:B Changeovervalveenergizedinheating
O Changeovervalveenergizedincooling
G Fanrelay
Y Compressor contactor
W Heat relay
C 24Vaccommon.For2-transformersystems,usecommonwirefromcoolingtransformer.
R 24Vacpowerfromheatingtransformer
Rc 24Vacpowerfromcoolingtransformer
TH2210DV/TH1210DV:B Changeovervalveenergizedin
heating
O Changeovervalveenergizedincooling
G Fanrelay
Y Compressor contactor
Aux/E Auxiliaryheatrelay
C 24Vaccommon
R 24Vacpower
TH1100DV:W Heat relay
C 24Vaccommon
R 24Vacpower
Terminal designations
Wiring
M32808BRWYGB RcO C
TH2110DV/TH1110DV
CYGOB RAux/E
M32809B
TH2210DV/TH1210DV
NotUsed
M34673
INSERT BATTERIES FORPRIMARY OR BACKUP POWER
M34699KEEP WIRES INTHIS SHADED AREA
REMOVE FACTORY-INSTALLED JUMPERONLY FOR TWO-TRANSFORMER SYSTEMS
CONNECT C FOR PRIMARYAC POWER (OPTIONAL IF BATTERIES ARE INSTALLED)
RC
R
C
W
Y
G
O
BTERMINALBLOCK SHOWN
M34800RW C
TH1100DH
Installation Guide
469-2800EFS—01
Wiring
2H/1C Heat Pump System TH2210DV/TH1210DV
B Changeovervalveenergizedin heating[5]
O Changeovervalveenergizedin cooling[5]
G FanrelayY Compressor contactorAux/E AuxiliaryheatrelayC 24Vaccommon[3]R Power[1]
1H/1C System TH2110DV/ TH1110DV
(1 transformer)G FanrelayY Compressor contactorW Heat relayC 24Vaccommon[3]R [R+Rcjoinedbyjumper]Rc Power[1]
1H/1C System TH2110DV/ TH1110DV
(2 transformers)G FanrelayY Compressor contactorW Heat relayC 24Vaccommon[3,4]R Power(heatingtransformer)[1,2]Rc Power(coolingtransformer)[1,2]
Heat Only System TH1100DV
W Heat relayC 24Vaccommon[3]R Power[1]
1H/1C Heat Pump System TH2110DV/TH1110DV [7]
B Changeovervalveenergizedin heating[5]
O Changeovervalveenergizedin cooling[5]
G FanrelayY Compressorcontactor[6]W [W+Yjoinedbyjumper]C 24Vaccommon[3]R [R+Rcjoinedbyjumper]Rc Power[1]
Heat Only System TH2110DV/TH1110DV
W Heat relayC 24Vaccommon[3]R [R+Rcjoinedbyjumper]Rc Power[1]
Heat Only System with Fan TH2110DV/TH1110DV
G FanrelayW Heat relayC 24Vaccommon[3]R [R+Rcjoinedbyjumper]Rc Power[1]
Cool Only System TH2110DV/TH1110DV
G FanrelayY Compressor contactorC 24Vaccommon[3]R [R+Rcjoinedbyjumper]Rc Power[1]
NOTESWirespecifications:
Use18-to22-gaugethermostatwire. Shieldedcableisnotrequired.
[1] Powersupply.Providedisconnectmeansandoverloadprotectionasrequired.
[2] Removejumperfor2-transformersystems. [3] Optional24Vaccommonconnection.
[4] Commonconnectionmustcomefromcool-ingtransformer.
[5] UseeitherOorBterminalsforchangeovervalve.
[6] Useasmallpieceofwire(notsupplied)toconnectWandYterminals.
[7] SetfanoperationswitchtoHeat Pump (seepage5).
Wiring guide — conventional and heat pump systems
CYGOB RAux/E
M32809B
TH2210DV/TH1210DV
NotUsed
RcCY WG RM32811
RcCY WG RM32812
RcCY WGOB RM32813
RcCW RM32814
RcCWG RM32815
RcCYG RM32816
See[notes]below
M34801RW C
PRO TH2000DV/TH1000DV Series
5 69-2800EFS—01M34679
Set
Cool
77 On
FanAuto
On
C IS OPTIONAL WITH BATTERIES
NOTUSED
R
C
AUX/E
Y
G
O
B
FanAuto
On
Off
Cool
Heat
Set
Hold
Run
E.M. Heat
M34676
Set
Cool
77 On
FanAuto
On
Off
Cool
Heat
C IS OPTIONAL WITH BATTERIES
RC
R
C
W
Y
G
O
B
TH2110DV/TH1110DV only:• Gas or Oil:Forgasoroilheatingsystems,leavethefanoperationswitchinthisfactory-setposition.(Thissettingisforsystemsthatcontrolthefaninacallforheat.)
• Electric or Heat Pump:Changetheswitchtothissettingforheatpumporelectricheatsystems.(Thissettingisforsystemsthatallow the thermostat to control the faninacallforheat,ifafanwireis connected to the Gterminal.)
Alignthethermostatwiththetabsonthewallplate,thenpushgentlyuntilthether-mostat snaps in place.
Thermostatmounting
Setfanoperationswitch.
Pushexcesswirebackintothewallopening.
Plugwallopeningwithnon-flammableinsulation.
Fanoperationsettings
M34674
ELECTRIC OR HEAT PUMP
GAS OR OIL
ELECTRIC OR HEAT PUMP
GAS OR OIL
Installation Guide
669-2800EFS—01
5 5
M32819
Followtheprocedurebelowtoconfigurethethermostattomatchtheinstalledheating/coolingsystem,andcustomizefeatureoperationasdesired.
Functionnumber
Setting
Tobegin,press and hold the s and tbuttonsuntilthedisplaychanges.
Press the s or tbuttontochangethesetting.
Press the s and tbuttonssimultaneouslyforonesecondtoadvancetothenextfunction.
Press and hold the s and tbuttonstoexitandsavesettings.
Installersetup
M34680
FanAuto
On
Off
Cool
Heat
Set
Hold
Run
E.M. Heat
M34681
Set
Cool
77 On
FanAuto
On
Off
Cool
Heat
NOTE:Ifyoudonotpressanybuttonfor60secondswhileyouareinthesetupmenu,thethermostatautomaticallysavesanychangesmadeandexitsthemenu.
PRO TH2000DV/TH1000DV Series
7 69-2800EFS—01
Setup function Settings & options (factory default in bold)
5 Heating cycle rate (CPH: cycles/hour) TH2110DV, TH1110DV and TH1100DV
5 For gas or oil furnaces of less than 90% efficiency1 Forsteamorgravitysystems3 Forhotwatersystems&furnacesofover90%efficiency6 Forelectricfurnaces
[Othercyclerateoptions:2or4CPH]
6 Auxiliary heat cycle rate (CPH) TH2210DV and TH1210DV
3 For hot water systems & furnaces of over 90% efficiency
1 Forsteamorgravitysystems5 Forgasoroilfurnacesoflessthan90%efficiency6 Forelectricfurnaces
[Othercyclerateoptions:2or4CPH]
9 Compressor cycle rate (CPH)
3 Recommended for most compressors [Othercyclerateoptions:1,2,4,5,or6CPH]
13 Early Start (TH2110DV and TH2210DV)
1 On **See page 80 Off
14 Temperature display
0 Fahrenheit1 Celsius
15 Compressor protection
1 Five-minute compressor off time (See page 8)0 Nocompressorofftime
20 Clock display (TH2110DV and TH2210DV)
0 12-hour display1 24-hourdisplay
25 Lower temperature range (TH1100DV only)
0 Standard range 40°F to 90°F (4.5°C to 32°C)1 Lowerrange(forgaragemode)35°Fto90°F
(1.5°Cto32°C)
40 Restore program schedule to default (TH2110DV and TH2210DV)
0 Off1 On-programscheduledefaultsettingsarelistedinthe
operatingmanual
Installersetup
CAUTION: EQUIPMENT DAMAGE HAZARDCompressorprotectionisbypassedduringtesting.Topreventequipmentdamage,avoidcyclingthecompressorquickly.
NOTE: Theoptionsbelowmaynotbeavailableinallmodels.
Installation Guide
Automation and Control Solutions
Honeywell International Inc.
1985DouglasDriveNorth
GoldenValley,MN55422
http://customer.honeywell.com
® U.S. Registered Trademark© 2013 Honeywell International Inc.69-2800EFS—01M.S.05-13Printed in U.S.A.
Early Start (SetupFunction13):Earlystartallowstheheatingorcoolingtoturnonbeforetheprogramstarttime,sothetemperatureisreachedatthetimeyouset.
Compressor Protection(SetupFunction15):Forcesthecompressortowaitafewminutesbeforerestarting,topreventdamage.Duringthewaittime,themessageCoolOnorHeatOn(heatpumpsonly)willflashonthedisplay.
Please contact your distributor to order replacement parts.Cover plate assembly* ........................................ PartNumber50002883-001
*Usetocovermarksleftbyoldthermostats.
Temperature Ranges
• Heat:40°to90°F(4.5°to32°C)
• Cool:50°to99°F(10°to37°C)
Operating Ambient Temperature
• 32°to120°F(0°to48.9°C)
Shipping Temperature
• -20°to120°F(-28.9°to48.9°C)
Operating Relative Humidity
• 5%to90%(non-condensing)
Physical Dimensions
• 3-7/16”Hx4-10/16”Wx1-3/16”D 87mmHx119mmWx30mmD
Electrical Ratings
System Voltage(50/60Hz) RunningCurrent
Heat(1ststage) 20-30Vac 0.02-1.0A
(Powerpile) 750mVDC 100mADC
Auxiliaryheat 20-30Vac 0.02-1.0A
Cooling 20-30Vac 0.02-1.0A
Accessories&replacementparts
Specialfunctions
Specifications
®MarquedéposéeauxÉ.-U.Brevetseninstance.
© 2013 Honeywell International Inc. Tousdroitsréservés.
Guide d’installation
Série PRO TH2000DV/TH1000DVThermostats
Doit être installé par un technicien d’expérience ayant reçu la formation pertinente.
Lireattentivementlesinstructions.Lefaitdenepaslessuivrerisqued’endommagerleproduitoudeconstituerundanger.
Besoin d’aide?Pourobtenirdel’assistanceausujetdeceproduit,
consulterlehttp://customer.honeywell.comoutéléphonersansfrais auCentredeserviceàlaclientèledeHoneywellau1800468-1502
Le présent guide porte sur les modèles suivants :• TH1100DV:Poursystèmesdechauffageseulement• TH2110DV/TH1110DV:Poursystèmesà1étagedechauffage/1étagederefroidissement• TH2210DV/TH1210DV:Pourthermopompesà2étagesdechauffage/1étagederefroidissementseulement
(Retirerlethermostatdelaplaquemuraleetleretournerpourtrouverlenumérodemodèle.)
Types de systèmeTH2110DV/TH1110DV :• Gaz,mazoutouchauffageélectrique
avec climatisation
• Airchaud,eauchaude,appareilsdechauffageàhautrendement,thermopompesà1étagedechauffage/1étagederefroidissement,vapeuretgravité
• Chauffageseulement
• Chauffageseulementavecventilateur
• Refroidissementseulement
• Systèmesdechauffage750mV
TH2210DV/TH1210DV :• Thermopompesà2étagesdechauffage/1étagederefroidissement
TH1100DV:• Gaz,mazoutouchauffageélectrique
• Airchaud,eauchaude,vapeuretgravité
• Chauffageseulement
• Systèmesdechauffage750mV
269-2800EFS—01
Guide d’installation
Installationdelaplaquemurale
AVIS SUR LE MERCURESilenouveauthermostatremplaceunancienrégulateurcontenantuncontactàmercure,nepasmettrel’ancienrégulateurauxpoubelles.ContactezleThermostatRecyclingCorporationàwww.switchthestat.caoule416-922-2448pourobtenirdel'informationsurlafaçonetl'endroitappropriésdevousdébarrasserdevotrevieuxthermostat.
MISE EN GARDE : RISQUE DE CHOC ÉLECTRIQUEPeutprovoquerdeschocsélectriquesouendommagerlematériel.Couperl’alimentationélectriqueavantd’effectuerleraccordement.
Séparerlaplaquemuraleduthermostatcommel’indiquel’illustrationci-contre,puissuivrelesdirectivesd’installation.
1. Fairepasserlesfilsparl’ouvertureréservéeauxfils.
2. Placerlaplaquemuralesurlemur,mettredeniveauetmarqueraucrayonl’emplacementdestrous.
3. Percerlestrousauxendroitsmarquésàl’aided’uneperceuse,puisinsérerleschevillesd’ancragefournies.
4. Apposerlaplaquemuralesurleschevilles,insérerpuisresserrerlesvisdefixation.
Tirerlethermostatparlebaspourledétacherdelaplaquemurale.
Utiliserunemèchede3/16po silemurestenplacoplâtre.
Utiliserunemèchede7/32po silemurestenplâtre.
M34683
C IS OPTIONAL WITH BATTERIES
NOTUSED
R
C
AUX/E
Y
G
O
B
M34682
Ancragesmuraux
Troudufil
Visdemontage
3 69-2800EFS—01
Série PRO TH2000DV/TH1000DV
Optionsd’alimentation
TH2110DV/TH1110DV :B Vanned’inversiondéclenchéeenmode
dechauffage
O Vanned’inversiondéclenchéeenmodederefroidissement
G Relaisdeventilateur
Y Contacteurducompresseur
W Relaisdechauffage
C Commun24Vc.a.Danslessystèmesàdeuxtransformateurs,utiliserlefilcommundutransformateurderefroidissement.
R Alimentation24Vc.a.provenantdutransformateurdechauffage
Rc Alimentation24Vc.a.provenantdutransformateurderefroidissement
TH2210DV/TH1210DV :B Vanned’inversiondéclenchéeen
modedechauffage
O Vanned’inversiondéclenchéeenmodederefroidissement
G Relaisdeventilateur
Y Contacteurducompresseur
Aux/E Relaisdesystèmedechauffageauxiliaire
C Commun24Vc.a.
R Alimentation24Vc.a.
Désignation des bornes
Câblage
M32808BRWYGB RcO C
TH2110DV/TH1110DV
CYGOB RAux/E
M32809B
TH2210DV/TH1210DV
Non utilisée
TH1100DV :W Relaisdechauffage
C Commun24Vc.a.
R Alimentation24Vc.a.
MF34673
INSÉRER LES PILES POUR L’ALIMENTATIONPRIMAIRE OU DE SECOURS.
MF34699
GARDER LES FILS DANSCETTE ZONE OMBRAGÉE
RETIRER LE CAVALIER INSTALLÉ EN USINESEULEMENT SI LE SYSTÈME EST À DEUXTRANSFORMATEURS
RACCORDER LA BORNE CPOUR L’ALIMENTATIONPRINCIPALE EN C.A. (OPTIONNELSI DES PILES SONT INSTALLÉES).
BORNIER
RC
R
C
W
Y
G
O
B
M34800RW C
TH1100DH
469-2800EFS—01
Guide d’installation
CâblageGuide de câblage – systèmes classiques et thermopompes
Thermopompes 2C/1F TH2210DV/TH1210DV
B Vanned’inversiondéclenchéeenmodedechauffage[5]
O Vanned’inversiondéclenchéeenmodederefroidissement[5]
G RelaisdeventilateurY ContacteurducompresseurAux/E Relaisdesystèmedechauffageauxili-
aire[9]C Commun24Vc.a.[3]R Alimentation[1]
Système 1C/1F TH2110DV/ TH1110DV
(1 transformateur)G RelaisdeventilateurY ContacteurducompresseurW RelaisdechauffageC Commun24Vc.a.[3]R [R+Rcreliéesparuncavalier]Rc Alimentation[1]
Système 1C/1F TH2110DV/ TH1110DV
(2 transformateurs)G RelaisdeventilateurY ContacteurducompresseurW RelaisdechauffageC Commun24Vc.a.[3,4]R Alimentation(transformateur,
chauffage)[1,2]Rc Alimentation(transformateur,refroid-
issement)[1,2]
Heat Only System TH1100DV
W RelaisdechauffageC Commun24Vc.a.[3]R Alimentation[1]
Thermopompe 1C/1F TH2110DV/TH1110DV [7]
B Vanned’inversiondéclenchéeenmodedechauffage[5]
O Vanned’inversiondéclenchéeenmodederefroidissement[5]
G RelaisdeventilateurY Contacteurducompresseur[6]W [W+Yreliéesparuncavalier]C Commun24Vc.a.[3]R [R+Rcreliéesparuncavalier]Rc Alimentation[1]
Système de chauffage seulement TH2110DV/TH1110DV
W RelaisdechauffageC Commun24Vc.a.[3]R [R+Rcreliéesparuncavalier]Rc Alimentation[1]
Système de chauffage seulement avec ventilateur TH2110DV/TH1110DV
G RelaisdeventilateurW RelaisdechauffageC Commun24Vc.a.[3]R [R+Rcreliéesparuncavalier]Rc Alimentation[1]
Système de refroidissement seulement TH2110DV/TH1110DV
G RelaisdeventilateurY ContacteurducompresseurC Commun24Vc.a.[3]R [R+Rcreliéesparuncavalier]Rc Alimentation[1]
REMARQUESCaractéristiquestechniquesdesfils:
Utiliserdufilpourthermostatdecalibre18à22.Iln’estpasnécessaired’utiliserdufilblindé.
[1] Alimentation:Fourniraubesoinundispositifdecoupureetuneprotectioncontrelessurcharges.
[2] Retirer le cavalierdanslecasdesystèmesàdeuxtransformateurs.
[3] Connexioncommune24Vc.a.enoption.
[4] Laconnexioncommunedoitprovenirdutransformateurderefroidissement.
[5] UtilisersoitlaborneOsoitlaborneBpourla vanne d’inversion.
[6] Utiliserunpetitboutdefil(nonfourni)pourraccorderlesbornesWetY.
[7] Réglerlesélecteurduventilateuràlaposition Thermopompe (Heat Pump) (voirpage5).
CYGOB RAux/E
M32809B
TH2210DV/TH1210DV
Non utilisée
RcCY WG RM32811
RcCY WG RM32812
RcCY WGOB RM32813
RcCW RM32814
RcCWG RM32815
RcCYG RM32816
Voir[remarques]ci-dessous
M34801RW C
5 69-2800EFS—01
Série PRO TH2000DV/TH1000DV
Alignerlethermostatavecleslanguettessurlaplaquemurale,puisappuyerdoucementjusqu'àcequ'ils'emboîte.
Montageduthermostat
Réglerlesélecteurduventilateur.
Repousserlefilen excèsdansl’ouverturedanslemur.
Boucherl’ouverturedanslemuraumoyend’unisolantininflammable.
TH21100DV/TH1110DV seulement :• Gaz ou mazout : Danslecasdesystèmesdechauffageaugazouaumazout,laisserlesélecteurduventilateuràlapositionrégléeenusine.(Ceréglageconvientauxsystèmesquicommandentlefonctionnementduventilateurlorsd’unedemandedechauffage.)
• Électricité ou thermopompe : Déplacerlesélecteuràcettepositionsilesystèmeestunethermopompeouunappareildechauffageélectrique.(Àcetteposition,lethermostatcommandelamiseenmarcheduventilateurlorsd’unedemandedechaleursiunfilduventilateurestraccordéàlaborneG.)
Réglageduventilateur
M34674
ELECTRIC OR HEAT PUMP
GAS OR OIL
ELECTRIC OR HEAT PUMP
GAS OR OIL
M34679
Set
Cool
77 On
FanAuto
On
C IS OPTIONAL WITH BATTERIES
NOTUSED
R
C
AUX/E
Y
G
O
B
FanAuto
On
Off
Cool
Heat
Set
Hold
Run
E.M. Heat
M34676
Set
Cool
77 On
FanAuto
On
Off
Cool
Heat
C IS OPTIONAL WITH BATTERIES
RC
R
C
W
Y
G
O
B
669-2800EFS—01
Guide d’installation
Suivrelesdirectivesci-dessouspourconfigurerlethermostatpourqu’ilcor-respondeausystèmedechauffage-refroidissementinstallé,etpourpersona-lisersonfonctionnement.
Numérodefonction
Réglage
Modedeconfigurationparl’installateur
Pourcommencer,Appuyersurlesboutons s et tlesmaintenirenfoncésjusqu’àcequel’affichagechange.
Appuyersurleboutons ou t pourmodifierlesréglages.
Appuyersimultanémentsurlesboutonss et t pendantunesecondepourpasseràlafonctionsuivante.
Appuyersurlesboutons s et t etlesmaintenirenfoncéespourquitteretenregistrerréglages.
5 5
M32819
M34680
FanAuto
On
Off
Cool
Heat
Set
Hold
Run
E.M. Heat
M34681
Set
Cool
77 On
FanAuto
On
Off
Cool
Heat
REMARQUE :Siaucunboutonn’esttouchépendant60secondesdanslemenudeconfiguration,lethermostatenregistreautomatiquementtoutemodificationeffectuéeetquittelemenu.
7 69-2800EFS—01
Série PRO TH2000DV/TH1000DV
Fonctions Réglage et options (réglages de l’usine en gras) 5 Nombre de cycles de
chauffage à l’heure (CPH : cycles par heure) TH2110DV, TH1110DV et TH1100DV
5 Pour les appareils au gaz ou au mazout à moins de 90 % d’efficacité
1 Systèmesàvapeurouàgravité3 Systèmesetappareilsdechauffageàeauchaudeàplusde90%d’efficacité
6 Pourappareilsdechauffageélectriques [autresCPHpossibles:2ou4CPH]
6 Cycles par heure du chauffage auxiliaire (CPH) TH2210DV, TH1210DV
3 Systèmes et appareils de chauffage à eau chaude à plus de 90 % d’efficacité
1 Systèmesàvapeurouàgravité5 Pourlesappareilsaugazouaumazoutàmoinsde 90%d’efficacité
6 Pourappareilsdechauffageélectriques [autresCPHpossibles:2ou4CPH]
9 Cycles par heure du com-presseur (CPH)
3 Recommandé pour la plupart des compresseurs [Autresoptionspossibles:1,2,4,5ou6CPH]
13 Démarrage précoce (TH2110DV et TH2210DV)
1 En marche **Voir page 80 Àl’arrêt
14 Affichage de la température
0 Fahrenheit1 Celsius
15 Protection du compresseur
1 Temporisation de 5 minutes (Voir page 8)0 Aucuntempsdecoupureducompresseur
20 Affichage de l’horloge (TH2110DV et TH2210DV)
0 Format 12 heures1 Format24heures
25 Gamme de température faible (TH1100DV seule-ment)
0 Gamme standard 4,5 ° à 32 °C (40 ° à 90 °F)1 Gammefaible(pourlemodegarage)1,5°à32°C (35°à90°F)
40 Restaurer le réglage par défaut du calendrier (TH2110DV et TH2210DV)
0 Arrêt1 On(Marche)-Lesréglagespardéfautducalendriersontindiquésdanslemanueldefonctionnement
Modedeconfigurationparl’installateur
MISE EN GARDE : RISQUE DE DOMMAGE MATÉRIELLesystèmenetientpascomptedutempsd’arrêtminimalducompresseurpendantletestparl’installateur.Pouréviterd’endommagerlematériel,éviterlescyclesdefonctionnementtroprapidesducompresseur.
REMARQUE : Lesoptionsci-dessousnesontpasdisponiblespourtouslesmodèles.
Guide d’installation
®MarquedecommercedéposéeauxÉ.-U.© 2013 Honeywell International Inc.69-2800EFS—01M.S.05-13ImpriméauxÉtats-Unis
Solutions de régulation et d’automatisation
Honeywell International Inc.
1985DouglasDriveNorth
GoldenValley,MN55422
http://customer.honeywell.com
FonctionsspécialesDémarrage précoce (fonctiondeconfiguration13):Ledémarrageprécocepermetàl'appareildechauffageetauclimatiseurdesemettreenmarcheavantletempsprogrammépourquelatempératurevouluesoitobtenueàl'heureprogrammée.
Protection du compresseur(Configurationdelafonction15):Cettefonctionobligelecompresseuràattendrequelquesminutesavantderedémarrer.Pendantcetteattente,lesmots«CoolOn»(ou«HeatOn»silesystèmeutiliséestunethermopompe)clignotentàl’écran.
Accessoiresetpiècesderechange
Prière de communiquer avec le distributeur pour commander des pièces de rechange.Ensemble de plaques de recouvrement* ............................. N°depièce50002883-001
*Sertàmasquerlesmarqueslaisséesparl’ancienthermostat.
CaractéristiquestechniquesGammes de température• Chauffage:4,5°à32°C(40°à90°F)• Refroidissement:10°à37°C(50°à99°F)
Gamme de température ambiante de service • 0°à48,9°C(32°à120°F)
Température à l’expédition• -28,9°à48,9°C(-20°à120°F)
Humidité relative de service• 5%à90%(sanscondensation)
Encombrement
• 3-7/16poHx4-10/16poLx1-3/16poP 87mmHx119mmLx30mmP
Caractéristiques électriques nominales
Système Tension Intensité (50/60Hz) deservice
Chauffage(1erétage) 20-30Vc.a. 0,02-1,0A
(Powerpile) 750mVc.c. 100mAc.c.
Chauffageauxiliaire 20-30Vc.a. 0,02-1,0A
Refroidissement 20-30Vc.a. 0,02-1,0A
®MarcaregistradadelosEE.UU.Patentesentrámite.
©2013,HoneywellInternationalInc. Todos los derechos reservados.
Guía de instalación
Serie PRO TH2000DV/TH1000DVTermostatos
Este manual incluye los siguientes modelos:• TH1100DV:ParasistemasdeSólocalor• TH2110DV/TH1110DV:Parasistemasde1calentadory1refrigerador• TH2210DV/TH1210DV:Parasistemasdebombadecalorpara2calentadoresy1regrigerador
únicamente (Quiteeltermostatodelaplacaparaparedygíreloparaverelnúmerodemodelo).
Tipos de sistemaTH2110DV/TH1110DV:• Sistemadecalefacciónagas,aaceiteoeléctricoconaireacondicionado
• Calefaccióndeaire,aguacaliente,sistemasdecalefaccióndealtaefectividad,bombasdecalorpara1calentadory1refrigerador,vapor,gravedad
• Sólocalor
• Sólocalorconventilador
• Sólofrío
• Sistemasdecalefacciónde750mV
TH2210DV/TH1210DV:• Sistemadebombadecalorpara2calentadoresy1refrigerador
TH1100DV:• Sistemadecalefacciónagas,aaceiteoeléctrico
• Calefaccióndeaire,aguacaliente,vapor,gravedad
• Sólocalor
• Sistemasdecalefacciónde750mV
Debe ser instalado por un técnico capacitado y experimentado
Leaestasinstruccionesatentamente.Sinosigueestasinstrucciones, puededañarelproductouocasionarunriesgo.
¿Necesita asistencia?Paraobtenerasistenciarelacionadaconesteproducto,visite
http://customer.honeywell.comocomuníqueseconelnúmerogratuitodel serviciodeatenciónalclientedeHoneywell,llamandoal1-800-468-1502
269-2800EFS—01
Guía de instalación
C IS OPTIONAL WITH BATTERIES
NOTUSED
R
C
AUX/E
Y
G
O
B
M34682
Instalacióndelaplacaparapared
Quitelaplacaparapareddeltermostatocomosemuestraalaizquierda,yluegosigalasinstruccionesparaelmontaje.
1. Haleloscablesatravésdelagujeroparaloscables.
2. Coloquelaplacaenlapared,niveleymarquelasposicionesdelosagujeros.
3. Realiceagujerosenlasposicionesmarcadascomosemuestraabajoeintroduzcalasanclasdeexpansióncongolpesleves.
4. Coloquelaplacaparaparedsobrelasanclasdeexpansión,introduzcalostornillosdemontajeyajústelos.
Haledelaparteinferiorparaquitar el termostato de la placa para pared.
PRECAUCIÓN: RIESGO ELÉCTRICOPuedeocasionardescargaseléctricasodañarelequipo.Desconéctelodelafuentedeenergíaantesdecomenzarlainstalación.
Entablarroca,realiceagujerosde3/16". Enyeso,realiceagujerosde7/32".
AVISO SOBRE EL MERCURIOEncasodequeesteproductoreemplaceauncontrolquecontengamercurioentubosellado,evitearrojarelviejocontrolalabasura.ComuníqueseconThermostatRecyclingCorporationenwww.thermostat-recycle.orgollameal800-238-8192paraobtenerinformaciónsobrecómoydóndedesechardeformaadecuadaysegurasutermostatousado.
M34683
Anclasdeexpansión
Agujeroparaelcable
Tornillos de montaje
3 69-2800EFS—01
Serie PRO TH2000DV/TH1000DV
Opcionesdefuentesdeenergía
TH2110DV/TH1110DV:B Válvulainversoraalimentadadurantela
refrigeración
O Válvulainversoraalimentadadurantelarefrigeración
G Relédelventilador
Y Interruptorautomáticodelcompresor
W Relédecalor
C 24VCA.Paralossistemasde 2transformadores,utilicecablescomunesdesdeeltransformador delarefrigeración.
R Corrientede24VCAdeltransformadordecalefacción
Rc Corrientede24VCAdeltransformadorderefrigeración
TH2210DV/TH1210DV:B Válvulainversoraalimentadadurante
larefrigeración
O Válvulainversoraalimentadadurantelarefrigeración
G Relédelventilador
Y Interruptorautomáticodelcompresor
Aux/E Reléauxiliardecalor
C 24VCA
R Corrientede24VCA
Designación de terminales
Cableado
M32808BRWYGB RcO C
TH2110DV/TH1110DV
CYGOB RAux/E
MS32809B
TH2210DV/TH1210DV
No usado
TH1100DV:W Relédecalor
C 24VCA.
R Corrientede24VCA
MS34699
MANTENGA LOS CABLES EN ESTA ÁREA SOMBREADA
CONECTE C PARA SUMINISTRAR CORRIENTE CA (OPCIONAL SI LAS BATERÍAS ESTÁN INSTALADAS)
QUITE EL PUENTE INSTALADO EN LA FÁBRICA SÓLO EN LOS SISTEMAS CON DOS TRANSFORMADORES
SE MUESTRA EL BLOQUE DE TERMINALES
RC
R
C
W
Y
G
O
B
MS34673
COLOQUE LAS BATERÍAS PARA SUMINISTRO DE ENERGÍA PRINCIPAL O DE RESPALDO
M34800RW C
TH1100DH
469-2800EFS—01
Guía de instalación
Cableado
Sistema de bomba de calor de 2 calentadores y 1 refrigerador TH2210DV/TH1210DV
B Válvulainversoraalimentadadurante lacalefacción[5]
O Válvulainversoraalimentadadurante larefrigeración[5]
G RelédelventiladorY InterruptorautomáticodelcompresorAux/E Reléauxiliardecalor[9]C 24VCA[3]R Electricidad[1]
Sistema de 1 calentador y 1 refrigerador TH2110DV/TH1110DV(1 transformador)
G RelédelventiladorY InterruptorautomáticodelcompresorW RelédecalorC 24VCA[3]
R [R+Rcunidosporunpuente]Rc Electricidad[1]
Sistema de 1 calentador y 1 refrigerador TH2110DV/TH1110DV(2 transformadores)
G RelédelventiladorY InterruptorautomáticodelcompresorW RelédecalorC 24VCA[3,4]R Electricidad(transformadordecalefacción)[1,
2]Rc Electricidad(transformadorderefrigeración)[1,
2]
Heat Only System TH1100DV
W Heat relayC 24Vaccommon[3]R Electricidad[1]
Sistema de bomba de calor de 1 calen- tador y 1 refrigerador TH2110DV/TH1110DV [7]
B Válvulainversoraalimentadadurante lacalefacción[5]
O Válvulainversoraalimentadadurante larefrigeración[5]
G RelédelventiladorY Interruptorautomáticodelcompresor[6]W [W+Yunidosporunpuente]C 24VCA[3]R [R+Rcunidosporunpuente]Rc Electricidad[1]
Sistema sólo calor TH2110DV/TH1110DV
W RelédecalorC 24VCA[3]R [R+Rcunidosporunpuente]Rc Electricidad[1]
Sistema sólo calor ventilador TH2110DV/TH1110DV
G RelédelventiladorW RelédecalorC 24VCA[3]R [R+Rcunidosporunpuente]Rc Electricidad[1]
Sistema sólo frío TH2110DV/TH1110DV
G RelédelventiladorY InterruptorautomáticodelcompresorC 24VCA[3]R [R+Rcunidosporunpuente]Rc Electricidad[1]
NOTASEspecificacionesdelcable:
Usecableparatermostatodecalibre 18a22.Noserequierecableblindado.
[1] Fuentedealimentación.Proporciona elmediodedesconexiónylaproteccióncontrasobrecargasrequeridos.
[2] Para sistemas de2transformadoresquite elpuente.
[3] Conexiónde24VCAopcional.
[4] Laconexióncomúndebeprovenirdel transformadorderefrigeración.
[5] UseterminalesOoBparalaválvulainver-sora.
[6] Useuntrozopequeñodecable(noincluido)paraconectarlosterminalesWyY.
[7] Coloqueelinterruptordelventiladorenla posición“Heat Pump” (bomba de calor [vealapágina5]).
Guía de cableado: sistemas convencionales y de bomba de calor
CYGOB RAux/E
MS32809B
TH2210DV/TH1210DV
No usado
RcCY WG RM32811
RcCY WG RM32812
RcCY WGOB RM32813
RcCW RM32814
RcCWG RM32815
RcCYG RM32816
Vea[notas]abajoM34801RW C
5 69-2800EFS—01
Serie PRO TH2000DV/TH1000DV
TH2110DV/TH1110DV únicamente:• Gas o aceite:Parasistemasdecalefacciónagasoaaceite,dejeelinterruptordelventiladorenestaposiciónpredeterminadadefábrica(estaposiciónesparalossistemasquecontrolanelventiladorcuandosenecesitacalefacción).
• Bomba eléctrica o de calor:Cambieelinterruptoraestaposiciónparalossistemasdebombadecalorodecalefaccióneléctricos.(estaposiciónesparalossistemasquecontrolanelventiladorcuandosenecesitacalefacción.SiseconectauncabledelventiladoralterminalG).
Alinee el termostato con las pesta-ñasdelaplacademontajeyempujesuavementehastaqueeltermostatocalceensulugar.
Montaje del termostato
Interruptordefuncionamientodelventilador.
Coloqueelexcedente decableenelinterior delaaberturadelapared.
Tapelaaberturadela paredconunaislamiento noinflamable.
Configuracionesdefuncionamientodelventilador
M34679
Set
Cool
77 On
FanAuto
On
C IS OPTIONAL WITH BATTERIES
NOTUSED
R
C
AUX/E
Y
G
O
B
FanAuto
On
Off
Cool
Heat
Set
Hold
Run
E.M. Heat
M34676
Set
Cool
77 On
FanAuto
On
Off
Cool
Heat
C IS OPTIONAL WITH BATTERIES
RC
R
C
W
Y
G
O
B
M34674
ELECTRIC OR HEAT PUMP
GAS OR OIL
ELECTRIC OR HEAT PUMP
GAS OR OIL
669-2800EFS—01
Guía de instalación
Sigaelprocedimientoqueapareceacontinuaciónparaconfigurareltermostatoafindequesecorrespondaconelsistemadecalefacciónyrefrigeracióninstalado,yseleccionelasfuncionessegúnlodesee.
Númerodefunción
Configuración
Paracomenzar,pulseymantenga presionadoslosbotoness y thastaquecambielapantalla.
Presioneelbotóns o tparacambiarlaconfiguración.
Presionelosbotoness y talmismotiempoporunsegundoparairalafunciónsiguiente.
Pulseymantengapresionadoslosbotones s y t para salir y guardarlaconfiguración.
Configuracióndeinstalación
5 5
M32819
M34680
FanAuto
On
Off
Cool
Heat
Set
Hold
Run
E.M. Heat
M34681
Set
Cool
77 On
FanAuto
On
Off
Cool
Heat
NOTA:sinosepresionaningúnbotóndurante60segundosmientrasestéabiertoelmenúdeconfiguración,eltermostatosalvaguardaloscambiosautomáticamenteysaledelmenú.
7 69-2800EFS—01
Serie PRO TH2000DV/TH1000DV
Funciones de Configuraciones y opciones (las que vienen la configuración desde la fábrica aparecen en negrita)
5 Velocidad del ciclo térmi-co (CPH: ciclos por hora) TH2110DV, TH1110DV y TH1100DV
5 Para sistemas de calefacción a gas o a aceite de menos de un 90% de efectividad
1 Para sistemas de vapor o de gravedad3 Parasistemasdeaguacalienteysistemasdemásdeun
90%deefectividad6 Parasistemasdecalefaccióneléctricos
[Otrasopcionesderangodeciclos:2ó4CPH]
6 Velocidad del ciclo térmico auxiliar (CPH) TH2210DV, TH1210DV
3 Para sistemas de agua caliente y sistemas de más de un 90% de efectividad
1 Para sistemas de vapor o de gravedad5 Parasistemasdecalefacciónagasoaaceitedemenos
deun90%deefectividad6 Parasistemasdecalefaccióneléctricos
[Otrasopcionesderangodeciclos:2ó4CPH]
9 Rango de ciclos del compresor (CPH)
3 Recomendado para la mayoría de los compresores [Otrasopcionesderangodeciclos:1,2,4,5ó6CPH]
13 Encendido anticipado (TH2110DV y TH2210DV)
1 On (encendido) ** Vea la página 80 Off(apagado)
14 Visor de temperatura 0 Fahrenheit1 Celsius
15 Protección del compresor
1 Tiempo de apagado del compresor (Vea la página 8)0 Sin tiempo de apagado del compresor
20 Visualizador del reloj (TH2110DV y TH2210DV)
0 Visualizador de 12 horas1 Visualizadorde24horas
25 Rango de temperatura más bajo (solo TH1100DV)
0 Rango estándar 40°F a 90°F (4,5°C a 32°C)1 Rangomásbajo(paraelmodogaraje)35°Fa90°F(1,5°C
a32°C).
40 Restablecimiento del cronograma del programa a la configuración prede-terminada (TH2110DV y TH2210DV)
0 Off (apagado)1 On(encendido)-laconfiguracióndelcronogramadel
programaestánindicadosenelmanualdefuncionamiento
Configuracióndeinstalación
PRECAUCIÓN: PELIGRO DE DAÑO EN EL EQUIPODurantelaprueba,sedesactivalaproteccióndelcompresor.Paraevitardaños enelequipo,nopermitaqueelcompresorfuncioneavelocidadesaltas.
NOTA: Lasopcionesquesiguenpuedennoestardisponiblesentodoslosmodelos.
Guía de instalación
®MarcaRegistradaenlosE.U.A© 2013 Honeywell International Inc.69-2800EFS—01M.S.05-13ImpresoenEE.UU.
Soluciones para automatización y control
Honeywell International Inc.
1985DouglasDriveNorth
GoldenValley,MN55422
http://customer.honeywell.com
Encendido anticipado(funcióndeconfiguración13):permitequelarefrigeraciónolacalefacciónarranquenantesdelahoradeinicioprogramada,demaneraquesealcanceesatemperaturaalahoraqueustedconfiguró.
Protección del compresor(conversiónautomática[configuración15]):Hacequeelcompresordemoreunosminutosantesdevolverainiciarse,afindeevitardaños.Duranteeltiempodeespera,elmensaje“CoolOn”o“HeatOn”(bombasdecalorúnicamente)titilaráenlapantalla.
Póngase en contacto con su distribuidor para solicitar piezas de repuesto.
Ensamblado de la placa de cubierta* ........................... Númerodepieza50002883-001
*Úseloparacubrirlasmarcasquedejanlostermostatosviejos.
Rangos de temperatura• Calor:De40°Fa90°F (de4,5°Ca32°C)
• Frío:De50°Fa99°F (de10°Ca37°C)
Temperatura ambiente de funcionamiento• De32°Fa120°F (de0ºCa48,9°C)
Temperatura de embalaje• De-20°Fa120°F (de-28,9ºCa48,9°C)
Humedad relativa de funcionamiento• 5%a90%(nocondensable)
Dimensiones físicas• 3-7/16"dealturax4-10/16"deanchox1-3/16"deprofundidad 87mmdealturax119mmdeanchox30mmdeprofundidad
Rangos eléctricos
Sistema Voltaje(50/60Hz) Corriente
Calor(etapa1) de20a30VCA de0,02a1,0A
(Powerpile) 750mVCC 100mACC
Calentador de20a30VCA de0,02a1,0A auxiliar
Refrigeración de20a30VCA de0,02a1,0A
Accesoriosypiezasderepuesto
Funcionesespeciales
Especificaciones