600 MW Coal-fired Electric Generating Unit
FOR SALE
This Unit 1 power block is a coal-fired electric generating unit comprising a nominal 600 MW GE
steam turbine, tandem-compound 4-flow single reheat unit with throttle conditions of 3500 psig,
1050°F/1100°F. The Alstom steam generator is rated at approximately 4,650,000 lbs per hour capable of
burning bituminous coal only or a combination of bituminous coal and petcoke (up to a 70%/30%
blend). Coal pulverizers have significant design margin operating at ~70% for MCR firing.
The plant design heat rate with this power block is 8725 BTU/kw-hr with tubine control valves
wide open (VWO) and average ambient conditions in southeasern U.S. with a circular mechanical forced
draft cooling tower, an electrostatic precipitatior, and a wet limestone flue gas desulphurization system.
All cycle design has been incorporated into the equipment for sale and cycle information is available for
all other normally desired conditions.
Included with the block procurement of the equipment listed for sale is the design documentation
of the power block. This includes all drawings, specifications, calculations, 3D modeling etc at the stage
that currently exists. For sale separately are the continued services of the engineer of record for this
design.
All design associated with the equipment listed is complete as are the foundations and buildings
for the boiler, coal silo bay, and turbine building, including all foundations which are of a heavy mat
design on piles that can easily transfer to other locations. The General Arangement of the power block is
fairly standard and completely developed for the critical piping, which is included in the equipment for
sale. Balance-of-plant equipment and facilities have all been specified and are ready for procurement.
The plant back-end design can be adjusted to match the buyers air emissions requirements and the fully
developed site layouts can be adjusted to meet the buyer’s site conditions. All P&ID’s are complete as is
preliminary piping and electrical physical design. A comprehensive PrimaVera level 3 schedule of
procurement, engineering, construction, and start-up is developed based upon the existing site
construction plan.
Offered by:
Cambridge Energy Waste Management, Ltd. 540 Frontage Road, Suite 3345, Northfield, Illinois 60093 USA
+1.847.784.0035 FAX +1.847.784.0038
For Information Contact Rudy Tagle