Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
600-DCTLM
600 SERIES
INSTALLATIONAND
OPERATING INSTRUCTIONS
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 1
This page has been deliberately left blank.
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 2
Table of Contents
1 FEATURES........................................................................................................................4
2 DIMENSIONS...................................................................................................................5
3 WIRING DIAGRAM........................................................................................................6
4 PLUG INFORMATION AND SPECIFICATIONS ......................................................7
5 MENU FLOW DIAGRAM ..............................................................................................8
6 GENERAL OPERATION................................................................................................9
7 ALARMS AND ALARMS MUTE.................................................................................10
8 CONTRAST ADJUSTMENT ........................................................................................10
9 BILGE MONITOR .........................................................................................................10
10 SETUP MODE .............................................................................................................1110.1 DC ALARM SETUP........................................................................................................... 1110.2 BATTERY SETUP.............................................................................................................. 1210.3 DC CALIBRATION............................................................................................................. 1310.4 TANK ALARM SETUP......................................................................................................... 1410.5 TANK SETUP................................................................................................................... 1410.6 TANK CALIBRATION.......................................................................................................... 1510.7 LEGENDS SETUP ............................................................................................................. 16
11 PEUKERT’S DISCHARGE RATES CALCULATION ..........................................17
12 TANK CALIBRATION PROCEDURE....................................................................19
12.1 CUSTOM MODE ............................................................................................................... 1912.2 MARKING MODE .............................................................................................................. 20
13 USER NOTES...............................................................................................................21
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 3
This page has been deliberately left blank.
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 4
Notes.
1. Current monitoring is only available for one battery2. The Bilge monitor is only available when DC VOLTAGE INPUT 3 is not used for voltage monitoring.3. 10-180Ω and 240-33Ω senders can be used when installed in conjunction with BEPs Tank Sender Interface Unit (BEP
P/N 600 TLM-SIF).
1 Features
§ Dot Matrix LCD allowing full screen information for each function.§ Automatic back-lighting on key-press.§ Voltage monitoring for up to 3 battery banks.§ Adjustable high and low voltage alarms.§ Battery current monitoring. (1)
§ Software utilises Peukert’s exponent for battery capacity calculations.§ Suitable for battery banks up to 3000 Amp-Hours.§ Adjustable low Amp-Hour alarm.§ Bilge monitor function to monitor bilge pump operation. (2)
§ 16 selectable DC legends and 7 selectable bilge monitor function legends.§ Meter supplied with a 50mV - 450A shunt (BEP P/N - LB-450-50).
§ Tank level monitoring for up to 4 tanks.§ Adjustable high and low tank level alarms.§ Designed for use with 0-5V senders.(3)
§ 14 selectable tank legends.
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 5
2 Dimensions
Note. The meter is designed to be surface mounted or recessed into a 2.5mm panel.
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 6
3 Wiring Diagram
ACCHOUSE STARTBATTERY BATTBATTERY
FLOAT SW.
BILGE PUMP
LOA
D
BA
TT OR BILGE PUMP INPUTFOR BILGE MONITORING
OR
THIRD BATTERY INPUT
3 = +VOLTS BATT 3 OR BILGE MONITOR
BACKLIGHTINGPOSITIVE FEED
11 = TANK SENDER INPUT 312 = TANK SENDER INPUT 4
10 = TANK SENDER INPUT 29 = TANK SENDER INPUT 1
6 = SHUNT BATT7 = SHUNT LOAD
8 = GROUND
5 = BACK LIGHTING4 = EXTERNAL ALARM (NEG)
EXTERNALALARM -
1 = +9.5 TO 30 VDC2 = +VOLTS BATT 2
STRIP PLUG FOR TERMINATING.EASILY REMOVABLE CONNECTOR
SHOW METER CONNECTIONS FOR THE 600-DCTLM. IT IS NOT AN INSTALLATION DIAGRAM.PLEASE NOTE: THIS DRAWING IS A WIRING OVERVIEW ONLY, IT'S PURPOSE IS TO
PLEASE NOTE:
IT IS IMPORTANT TO USE SCREENED"TWISTED PAIR" CABLE. CABLE KIT'S 600-DCM-5M,600-DCM-10M CAN BE ORDERED SEPARATELY.
FULL EMPTY
NEG SENDPOS
POS NEG SEND
FULL EMPTY
NEG
SEND
NEGATIVE BAR
POSITIVEFEED
87 6
1AFuse
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 7
Notes.
1. Operating outside minimum / maximum operating parameters may result in erroneous operation or cause permanentdamage to the device.
2. The shunt must be connected to the same battery as DC VOLTAGE INPUT 1.
4 Plug Information and Specifications
Pin 1. METER POWER SUPPLY & DC VOLTAGE INPUT 1+10.5MIN to +30VMAX DC from battery bank 1 through a 1A fuse (for meter protection).Meter current consumption is approximately 50mA when the back-lighting is switched off.When the back-lighting is switched on current consumption increases to approximately 70mA.
Pin 2. DC VOLTAGE INPUT 20 to +30VMAX DC from Battery bank 2
Pin 3. DC VOLTAGE INPUT 3 OR POSITIVE FEED FROM BILGE PUMP0 to +30VMAX DC from Battery bank 3. Alternatively this input can be used as a bilge pumpmonitor. This is achieved by taking a positive feed from the pump side of the bilge pump floatswitch through a 1A fuse and enabling the meter’s bilge function.
Pin 4. EXTERNAL ALARM OUTPUTThis output can be wired to an external alarm (negative signal). This output is designed toswitch a small external relay and can sink a maximum 100mAMAX at 12V. The relay must havean in-built flyback diode.
Pin 5. BACK LIGHTING INPUTCan be connected to a +10.5VMIN to +30VMAX DC supply to bring the back-lighting onconstantly. The Back Lighting Input could be fed from the Instrumentation Lights circuit so thatthe backlighting is on when the dash is illuminated. Under normal operating conditions back-lighting will start and stay on with each button push for approximately 10 seconds.
Pin 6. DC CURRENT INPUT 1Connected to one core of a screened twisted pair cable from the BATTERY SIDE of theshunt. To be used with a 50mV @ 450Amp current shunt. (e.g. BEP P/N - LB-450-50)
Pin 7. DC CURRENT INPUT 1Connected to the other core of a screened twisted pair cable from the LOAD SIDE of theshunt. To be used with a 50mV @ 450Amp current shunt. (e.g. BEP P/N - LB-450-50)
Pin 8. DC GROUNDUse the screen of the twisted pair to go back to the LOAD SIDE of the shunt.
Pin 9. TANK SENDER INPUT 10 to 5VMAX DC from output of tank sender 1 (e.g. BEP P/N – TSTMW-60-100N)
Pin 10. TANK SENDER INPUT 20 to 5VMAX DC from output of tank sender 2 (e.g. BEP P/N – SHS-12 & 600-TLM-SIF)
Pin 11. TANK SENDER INPUT 30 to 5VMAX DC from output of tank sender 3 (e.g. BEP P/N – TSTMF-60-100N)
Pin 12. TANK SENDER INPUT 40 to 5VMAX DC from output of tank sender 4 (e.g. BEP P/N – TSTMW-15-30N)
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 8
5 Menu Flow Diagram
PO
WER
UP
BE
P L
OG
O
V/A
DC
VO
LTS
1D
C V
OLT
S 2
DC
VO
LTS
3D
C A
MPS
C C
APA
CIT
Y
RE
MA
ININ
G
(AH
)
CAP
AC
ITY
RE
MA
ININ
G
(%)
TTA
NK
1TA
NK
2T
ANK
3TA
NK
4
SE
TUP
DC
ALA
RM
S
ETU
P
BA
TTE
RY
S
ETU
P
DC
C
ALI
BR
ATI
ON
TAN
K A
LAR
M
SE
TUP
TAN
K S
ETU
P
MU
LTI T
AN
K
ALA
RM
S
RE
SET
A
LL
TAN
K
CA
LIB
RA
TIO
N
LEG
EN
D
SE
TUP
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 9
6 General Operation
After 5 secondsThe first screen shows the legend and voltage for DCVoltage Input 1. V/A
C
T
Press button ‘V/A’Press this button to scroll through the following pages :-
Page 1. DC Voltage 1Page 2. DC Voltage 2Page 3. DC Voltage 3 (or Bilge Monitor)Page 4. DC Current 1
V/A
C
T
Press button ‘C’Press this button to scroll through the following pages :-
Page 1. Capacity Remaining (Amp Hours)Page 2. Capacity Remaining (Percentage)
Note.
Battery capacity information is calculated using data fromDC Voltage Input 1 and DC Current Input 1 only See theWiring Diagram for an example connection scheme.
V/A
C
T
Apply PowerAfter applying power, the BEP logo will appear forapproximately 5 seconds.
V/A
C
T
Press button ‘T’Press this button to scroll through the following pages :-
Page 1. Tank Level 1Page 2. Tank Level 2Page 3. Tank Level 3Page 4. Tank Level 4Page 5. Multi Tank Display
V/A
C
T
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 10
7 Alarms and Alarms Mute
8 Contrast Adjustment
9 Bilge Monitor
V/A
C
T
The Bilge Monitor function monitors bilge pump operation24 hours, 7 days a week. It stores the number of bilge pumpoperations and the accumulated operating time. It can bereset when leaving the boat.
The Bilge Monitor function will be automatically set up whena bilge pump legend (i.e. ‘BILGE MID’) is selected for DCVoltage Input 3 ( ‘DCV3’ ) in the ‘LEGEND SETUP’ menu. Ifbilge monitoring is selected then voltage monitoring will beunavailable for that input.
When viewing the Bilge Monitor function press and holdbutton ‘T’ to reset the Bilge Monitor back to zero.
To adjust the contrast of the LCD screen press and holdbutton ‘V/A’ & button ‘C’ down simultaneously forapproximately 10 seconds.
The display will then change to a black pixilated screen.
§ Press button ‘T’ to switch between 7 different contrastadjustment screens.
§ Press button ‘V/A’ to adjust the contrast.
§ Press button ‘C’ to accept the adjusted contrast.
V/A
C
T
When the meters alarm function is enabled (see ‘SetupMenu’) the alarm symbol will be displayed on eachpage. When an alarm condition occurs, the meters alarmwill sound and the corresponding meter reading will flash.
To permanently mute all alarms, press and hold button ‘C‘.
The display will show the Alarm mute symbol. Repeatto reactivate the alarm.
Note. The alarms are muted by default when they are firstenabled.
V/A
C
T
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 11
10 Setup Mode
In setup mode the buttons are used to navigate the menus and change settings. The buttons functionin all menus as follows :-
Button ‘V/A’ : Up / Item Up / Increment ValueButton ‘C’ : Down / Item Down / Decrement ValueButton ‘T’ : Enter / Confirm
10.1 DC Alarm Setup
Entering the setup menuTo enter the setup menu press and hold button ‘V/A’ &button ‘T’ down simultaneously for approximately 3seconds. You will then be presented with the setup menu.Within the setup menu there are a number of submenuswhere you can configure different meter settings.
‘ALARMS’. This option will globally enable or disable themeter’s alarm functions. Select ‘ALARMS’. The menu itemwill flash. Use Button ‘V/A’ and Button ‘C’ to select betweenON, OFF, CONST ON and PULSE ON. Use Button ‘T’ toconfirm the selection.
‘RESET ALL’. This option will reset the meter back to thefactory default settings - all user settings will be lost. Firstselect ‘RESET ALL’. The menu item will flash. Use Button‘V/A’ and Button ‘C’ to select between ‘YES’ and ‘NO’. UseButton ‘T’ to confirm the selection. The display will flash forapprox 2-3 seconds. The unit has now been reset to thefactory default settings.
DCVN HIGHDEFAULT: 15.0V DCRESOLUTION: 0.1V DCRANGE: 0-32V DCDESCRIPTION: A voltage greater than or equal to thisvoltage will cause the alarm to function.
DCVN LOWDEFAULT: 11.0V DCRESOLUTION: 0.1V DCRANGE: 0-32V DCDESCRIPTION: A voltage less than or equal to this voltagewill cause the alarm to function.
LOW CAPDEFAULT: 100AHRESOLUTION: 10AHRANGE: 0-3000AHDESCRIPTION: When the battery capacity is less than orequal to this value the alarm will function.
D C V 1 L O W : 1 1 . 0 VD C V 2 H I G H : 1 5 . 0 VD C V 2 L O W : 1 1 . 0 VD C V 3 H I G H : 1 5 . 0 VD C V 3 L O W : 1 1 . 0 V
D C V 1 H I G H : 1 5 . 0 VE X I T
V/A
C
T
D C V 2 H I G H : 1 5 . 0 VD C V 2 L O W : 1 1 . 0 VD C V 3 H I G H : 1 5 . 0 VD C V 3 L O W : 1 1 . 0 VL O W C A P : 1 0 0 A H
D C V 1 L O W : 1 1 . 0 V
E X I T
V/A
C
T
D C A L A R M S E T U PB A T T E R Y S E T U PD C C A L I B R A T I O NT A N K A L A R M S E T U PT A N K S E T U P
A L A R M S : O F FE X I T
V/A
C
T
T A N K A L A R M S E T U PT A N K S E T U PT A N K C A L I B R A T I O NL E G E N D S E T U PR E S E T A L L : N O
D C C A L I B R A T I O N
E X I T
V/A
C
T
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 12
10.2 Battery Setup
ACT CAPDEFAULT: 220AHRESOLUTION: 10AHRANGE: 0-3000AHDESCRIPTION: The Actual Capacity is the present state ofcharge of battery bank 1 when the monitor is installed / setup. Ideally the battery will be fully charged and this value willinitially equal the maximum capacity ‘MAX CAP’. Use the‘RST CAPACITY’ function before adjusting.
MAX CAPDEFAULT: 220AHRESOLUTION: 10AHRANGE: 0-3000AHDESCRIPTION: The Maximum capacity of the battery.
RST VOLTDEFAULT: 13.5V DCRESOLUTION: 0.1V DCRANGE: 0-32V DCDESCRIPTION: The charging battery reset voltage. This setting works synergistically with the ‘RSTAMPS’ settings.
RST AMPSDEFAULT: 9ARESOLUTION: 1ARANGE: 0-450ADESCRIPTION: This should be changed to 4% of the battery bank Amp-hour rating. I.e. a 220Amp-hour battery bank = 220*0.04 = 8.8. Therefore use 9 Amps.
CHARGE EFFDEFAULT: 0.85RESOLUTION: 0.01RANGE: 0-1.00DESCRIPTION: Charging Efficiency is set at 85% i.e. the battery will only accept 85% of thecharge current. This is a difficult parameter to set as after 75% recharge, the efficiency will fall off to0% at full charge. The overall efficiency will change with temperature, battery condition, chargingcurrent/voltage and discharge level. Trial and error with general usage is the only way to determinethis value.
PEUKERT EXPDEFAULT: 1.24RESOLUTION: 0.01RANGE: 0-1.50DESCRIPTION: See the section ‘Peukert’s Discharge Rates Calculation’ for more information.
RST CAPACITYDEFAULT: NODESCRIPTION: Will reset the actual battery capacity to the set ‘MAX CAPACITY’. Reset capacityprovides the option to reset the capacity to the programmed maximum value (YES) or to leave it atthe current monitored level (NO). Reset the battery capacity after the meter is correctly installed,calibrated and the battery bank is fully charged.
Note. The battery capacity (Amp-Hours) is reset to the set maximum battery capacity ‘MAX CAP’when both of the following conditions have been met for 5 minutes :-
§ The Battery Voltage is greater than ‘RST VOLT’ (13.5V factory default).§ The Charge Current is less than ‘RST AMPS’ (9A factory default).
M A X C A P : 2 2 0 A HR S T V O L T : 1 3 . 5 VR S T A M P S : 9 . 0 AC H A R G E E F F : 0 . 8 5P E U K E R T E X P : 1 . 2 4
A C T C A P : 2 2 0 A HE X I T
R S T C A P A C I T Y : Y E S
V/A
C
T
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 13
10.3 DC Calibration
DCVN CALDEFAULT: N/ARESOLUTION: 0.1V DCRANGE: 0-30V DCDESCRIPTION: Used to calibrate the voltage for aparticular input. Adjust this value to correspond with aknown voltage applied to the input. This is factory calibratedand the parameter should not need adjustment.
HIAMP CALDEFAULT: N/ARESOLUTION: 1A DCRANGE: 41-450A DCDESCRIPTION: Used to calibrate the high current range.Adjust this reading to correspond with a known load appliedto the system. This is factory calibrated. If current calibrationis necessary, it should be performed under the maximumpossible load, within the specified range, after zeroing themeter with ‘GET AMP ZERO’, at no load.
LOAMP CALDEFAULT: N/ARESOLUTION: 0.1A DCRANGE: 0-40A DCDESCRIPTION: Used to calibrate the low current range.Adjust this reading to correspond with a known load appliedto the system. This is factory calibrated. If current calibrationis necessary it should be performed under the maximumpossible load, within the specified range, after zeroing themeter with ‘GET AMP ZERO’, at no load.
GET AMP ZERODEFAULT: N/ARESOLUTION: 0.1V DCRANGE: 0-450A DCDESCRIPTION: Used to calibrate the zero current point.This should be done after the meter and shunt are correctlyinstalled, and there is no system load. It is imperative thatthere is NO current running though the shunt.
D C V 2 C A L : 0 . 0 VD C V 3 C A L : 0 . 0 VH I A M P C A L : - 1 0 0 AL O A M P C A L : - 3 0 . 0 AG E T A M P Z E R O : N O
D C V 1 C A L : 1 2 . 2 VE X I T
V/A
C
T
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 14
10.4 Tank Alarm Setup
10.5 Tank Setup
DISPDEFAULT: BAR GRAPHOPTIONS: BAR GRAPH / PERCENTAGEDESCRIPTION: Sets how the meter displays the tank levelinformation.
UNITSDEFAULT: LITRESOPTIONS: LITRES / IMGAL / USGALDESCRIPTION: Sets the units of volume for the tankinformation.
TANKN
DEFAULT: 500 UNITSRESOLUTION: VARIABLERANGE: 0-25000 UNITSDESCRIPTION: Sets the capacity (volume) of eachindividual tank. The capacity can be adjusted as per thefollowing table.
Lower Limit(UNITS)
Upper Limit(UNITS)
Step Size(UNITS)
# Steps
0 1000 10 1001000 3000 50 403000 10000 100 7010000 25000 500 30
U N I T S : L I T R E ST A N K 1 : 5 0 0T A N K 2 : 5 0 0T A N K 3 : 5 0 0T A N K 4 : 5 0 0
D I S P : P E R C E N T A G EE X I T
V/A
C
T
T A N K 2 L O W : 1 0 %T A N K 3 H I G H : 1 0 0 %T A N K 3 L O W : 1 0 %T A N K 4 H I G H : 1 0 0 %T A N K 4 L O W : 1 0 %
T A N K 2 H I G H : 1 0 0 %
E X I T
V/A
C
T
T A N K 1 L O W : 1 0 %T A N K 2 H I G H : 1 0 0 %T A N K 2 L O W : 1 0 %T A N K 3 H I G H : 1 0 0 %T A N K 3 L O W : 1 0 %
T A N K 1 H I G H : 1 0 0 %E X I T
V/A
C
T
TANKN HIGHDEFAULT: 100%RESOLUTION: 1%RANGE: 0-100%DESCRIPTION: A tank level greater than or equal to thispercentage will cause the alarm to function.
TANKN LOWDEFAULT: 10%RESOLUTION: 1%RANGE: 0-100%DESCRIPTION: A tank level less than or equal to thispercentage will cause the alarm to function.
Note. Any unused tank inputs must be grounded, the‘TANKN HIGH’ alarm set to 100% and the ‘TANKN LOW’alarm set to 0%.
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 15
10.6 Tank Calibration
C A L T Y P E : M A R K I N GE 0 . 0 0 V 1 0 . 2 5 V2 0 . 0 0 V 3 0 . 2 5 V4 0 . 0 0 V 5 0 . 2 5 V6 0 . 0 0 V 7 0 . 2 5 V
T A N K : T A N K 1E X I T
F 0 . 0 0 V
V/A
C
T
TANKDEFAULT: TANK1OPTIONS: TANK1 / TANK2 / TANK3 / TANK4DESCRIPTION: Selects which tank is to be calibrated
CAL TYPEDEFAULT: CUSTOMOPTIONS: CUSTOM / MARKINGDESCRIPTION: Selects the calibration mode for the tank.
‘CUSTOM’. In custom calibration mode the user can adjustthe required sender output voltage for each marking point.
‘MARKING’. In marking calibration mode the meter will readthe output voltage from the sender for each marking point.
See the section titled ‘Tank Calibration Procedure’ for moredetails.
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 16
10.7 Legends Setup
DCVNDEFAULT: SEE BELOWOPTIONS: SEE DC AND BILGE LEGENDS BELOW.DESCRIPTION: Sets the displayed legend for DC VoltageInputs 1, 2 and 3.
Note. Bilge Pump Legends are available for DC VoltageInput 3 only. Selecting a Bilge Pump legend will enable theBilge Monitor Function for this input.
TLMN
DEFAULT: SEE BELOWOPTIONS: SEE TANK LEGENDS BELOW.DESCRIPTION: Sets the displayed legend for Tank SenderInputs 1, 2, 3 and 4.
DC LEGENDS BILGE PUMPLEGENDS
TANKLEGENDS
HOUSE BATT(1) BILGE PUMP WATER(4)
START BATT(2) BILGE MON HOLDING(5)
HOUSE 1 BILGE STBD FUEL(6)
HOUSE 2 BILGE PORT GREY WTRSTART 1 BILGE AFT BLACKWTRSTART 2 BILGE MID FUEL MID
STBD START BILGE FWD FUEL AFTMID START FUEL FWD
PORT START FUEL STBDAUX BATT FUEL PORT
RADIO BATT(3) WTR MIDGENSET BATT WTR AFTBOW THRUST WTR FWDWINCH BATT WTR STBD
VAN BATT WTR PORTNOT USED NOT USED(7)
Notes.
1. Default legend for Voltage Input 1.2. Default legend for Voltage Input 2.3. Default legend for Voltage Input 3.4. Default legend for Tank Sender Input 1.5. Default legend for Tank Sender Input 2.6. Default legend for Tank Sender Input 3.7. Default legend for Tank Sender Input 4.
D C V 2 : S T A R T B A T TD C V 3 : R A D I O B A T TT L M 1 : W A T E RT L M 2 : H O L D I N GT L M 3 : F U E L
D C V 1 : H O U S E B A T TE X I T
T L M 4 : N O T U S E D
V/A
C
T
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 17
11 Peukert’s Discharge Rates Calculation
The meter uses Peukert’s Equation to calculate battery capacity. Peukert’s equation corrects forbattery inefficiencies and converts the discharge current to an effective discharge related to batterycapacity. Most marine batteries are capacity rated at the 20-hour rate. Ie: A battery discharged for 20hours to a terminal voltage of 10.5v = Amp hours.
C = A x T20 C = 5 x 20 = 100 Amp Hours.C = Battery capacity A = Amps discharge T20 = Time20 hours
Peukert’s EquationA x n x T = C
C = is battery capacity at 20hrs dischargeA = is discharge current in AmpsT = is discharge time in hoursn = is related to battery construction & is relatively constant for any given battery with in a similardischarge time.
Exponent “n” can be calculated for any given battery bank by comparing two discharge cycles.First fully charge battery bank from shore power/genset & discharge at 50% of expected average load(Note time & amps) to 10.5volt terminal voltage (12v system). Recharge fully & discharge at 150% ofexpected average load. Use the following equation.
n = Exponentt1 = The hours of first discharge at amps A 1t2 = The hours of 2nd discharge at amps A 2
Example:
8G4D 180A/HrDischarge 1 = 24 hours @ 7.8 AmpsDischarge 2 = 8 hours @ 20.7 Amps
Program this exponent in to the meters Peukerts setting.
Note. A 0.01 change to Peukerts Exponent can make a significant change to the calculateddischarge. Therefore Peukerts Exponent should be adjusted in small steps.
For example, 100 Amps for 1 hour = 100Amp-hours. Using a Peukert’s exponent of 1.25, A x n x T =100 x 1.25 x 1 = 316 Amp-hours. Thus a 25% exponent change makes 316% change.
Calculating exponent “n” from discharge cycles is the only way to achieve an accurate dischargeexponent. This meter comes with a factory set exponent of 1.25, which is a “rough” average for deepcycle flooded lead acid. If you do not wish to calculate “n” use Table 1 to select a typical “n” for yourbattery type.
If after some time or use (6-12months) the accuracy seems to be degrading (possibly due to batterycondition, temperature, age – charging regime) it will be necessary to recalculate “n”.
Log t2 - Log t1Log A1 - Log A2
Log 8 - Log 24Log 7.8 - Log 20.7
0.9 – 1.380.89 – 1.32
0.480.43
= 1.1n =
Log t2 - Log t1Log A1 - Log A2
n =
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 18
Table 1. Peukerts Exponents
Mode l Volts 20 Hr rating "n"8 G G C 6 1 8 0 1 .148 G U 1 1 2 4 3 1 .20
8 G U 2 4 1 2 7 0 1 .138 G U 2 7 1 2 8 6 1 .12
8GU30H 1 2 9 5 1 .128 4 D 1 2 1 8 0 1 .11
8 G 8 D 1 2 2 2 5 1 .10
Mode l Volts 20 Hr rating "n"R 2 2 0 6 2 2 5 1 .24L16 6 3 5 0 1 .28
U S 1 0 5 1 2 8 5 1 .23U S 1 3 0 1 2 1 3 0 1 .24U S 2 4 0 1 2 2 1 6 1 .17
V A L V E R E G U L A T E D G E L L E D B A T T E R I E S
E N D U R A N T ( U S B A T T E R I E S ) F L O O D E D B A T T E R I E S
Type Absorb Amps Float Amps A/Hrs (NZ)L16 14.47 11.00 13.50 3.00 350R220 14.53 6.60 13.50 3.10 220
US105 14.60 3.00 13.60 1.60 90148/17 14.58 3.30 13.60 1.60 90US130 14.50 3.00 13.80 2.00 115US240 14.40 7.40 13.80 4.40 210
Full charge analysis sheet
"A/Hrs NZ" -means estimated A/Hrs in NZ conditions
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 19
12 Tank Calibration Procedure
12.1 Custom Mode
Custom calibration mode allows the user to manually enter the required sender output voltages foreach marking point. This avoids the need of emptying the tank and then re-filling it. However thevalues must have been previously recorded for the tank and sender used.
Step 1. Tank Calculations
Determine the tank volume.
a) Total TANKN Volume = _ _ _ _ _ _ _ _
Step 2. Tank Setup
a) Enter the ‘TANK SETUP MENU’b) Set ‘DISP’ to the desired display type.c) Set ‘UNITS’ to the desired unitsd) Set ‘TANKN’ volume to that used in STEP 1a.
a) Enter the ‘TANK CALIBRATION MENU’b) Set ‘TANK’ as the tank to be calibrated.c) Select ‘CAL TYPE’ as ‘CUSTOM’.
Step 3. Marking
Each marking point will contain the previously calibrated values or default values if the meter hasbeen reset.
Highlight the first custom marking point ‘E’
E: Press Button ‘T to confirm the selected marking pointThe marking point will begin to flashUse Button ‘V/A’ & Button ‘C’ to adjust the voltage up and down to the required value.Press Button ‘T’ to enter and confirm the adjusted marking point.Press Button ‘C’ to move to the next marking point.
1: Press Button ‘T to confirm the selected marking pointThe marking point will begin to flashUse Button ‘V/A’ & Button ‘C’ to adjust the voltage up and down to the required value.Press Button ‘T’ to enter and confirm the adjusted marking point.Press Button ‘C’ to move to the next marking point.
2: Press Button ‘T to confirm the selected marking pointThe marking point will begin to flashUse Button ‘V/A’ & Button ‘C’ to adjust the voltage up and down to the required value.Press Button ‘T’ to enter and confirm the adjusted marking point.Press Button ‘C’ to move to the next marking point.
...: Repeat for marking points 3, 4, 5, 6, 7, and FULL.
Note. Button ‘V/A’ & Button ‘C’ can be used to manually move through the marking points.
Step 4. Complete
The custom tank calibration procedure is complete.
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 20
12.2 Marking Mode
Marking calibration mode allows the user to calibrate the meter for the first time and establish themarking value for future reference. This method requires the tank to be empty then gradually filledwith a predetermined volume of liquid until the tank is full. The sender output voltages can then berecorded for future reference.
Step 1. Empty the tank
Ensure the tank is empty.
Step 2. Tank Calculations
Complete the calculation below.
a) Total TANKN Volume = _ _ _ _ _ _ _ _b) TANKN Volume divided by 8 = _ _ _ _ _ _ _ _
Note. This is the amount of liquid that will be used to calibrate each marking point.
Step 3. Tank Setup
a) Enter the ‘TANK SETUP MENU’b) Set ‘DISP’ to the desired display type.c) Set ‘UNITS’ to the desired unitsd) Set ‘TANKN’ volume to that used in STEP 2a.
e) Enter the ‘TANK CALIBRATION MENU’f) Set ‘TANK’ as the tank to be calibrated.g) Select ‘CAL TYPE’ as ‘MARKING’.
Step 4. Marking
Select the first marking point ‘E’
E: The sender output voltage will be displayed under the flashing cursor.Press Button ‘T’ to set this marking point.The cursor will automatically move to the next marking point
1: Fill the tank with the volume of liquid calculated in STEP 2b.Wait for the sender output voltage displayed under the flashing cursor to stabilise.Press Button ‘T’ to set this marking point.The cursor will automatically move to the next marking point
2: Fill the tank with the volume of liquid calculated in STEP 2b.Wait for the sender output voltage displayed under the flashing cursor to stabilise.Press Button ‘T’ to set this marking point.The cursor will automatically move to the next marking point
...: Repeat for marking points 3, 4, 5, 6, 7, and FULL.
Note. Button ‘V/A’ & Button ‘C’ can be used to manually move through the marking points.
Step 5. Full
At this stage the total volume of liquid specified in STEP 2a should have been put in to the tank.
It is recommended to use the Notes section of this manual to record the sender output voltage foreach marking point. In the event the meter settings are lost, these can be manually entered to avoidthe need of emptying and then filling the tank.
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 21
13 User Notes
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 22
This page has been deliberately left blank.
Copyright © BEP Marine Limited, All rights reserved
INST-600-DCTLM-V1 SV1822/02/06
Page 23
BEP MARINE13 Tarndale Grove
Albany, Auckland, N.Z.Ph: +64 9 415 7261Fax: +64 9 415 9327www.bepmarine.com
BEP AUTOMOTIVE13 Tarndale GroveAlbany, Auckland, N.Z.Ph: +64 9 415 7261Fax: +64 9 415 9327www.bepautomotive.com
E-mail: [email protected]
Please visit our website for the latest International Distributor List