8/10/2019 55471, GS5-GS501Z-RCA-3.0
http://slidepdf.com/reader/full/55471-gs5-gs501z-rca-30 1/11Page 1 55471_97_
GS501Z Tech Sheet
55471_97_B.pdf 04/30/2008Template used: 40599_M.pdf 04/16/2008
Balboa InstrumentsSystem PN 55471
System Model # GS5-GS501Z-RCA-3.0Software Version # 43EPN # 2817
Base PCBA - PN 54512-01PCB GS500Z - PN 22015 Rev B
Base Panels VL401 (LCD Lite Duplex) – PN 54094
VL402 (LCD Duplex Digital) – PN 54093Optional Panels VL200 (Mini bath) – PN 52144 VL240 (MVP240) – PN 53643 VL260 (MVP260) – PN 53645
8/10/2019 55471, GS5-GS501Z-RCA-3.0
http://slidepdf.com/reader/full/55471-gs5-gs501z-rca-30 2/11Page 2 55471_97_
System Revision History
System PN EPN Date Requested By Changes Made55471 2817 04.07.2008 Balboa New system55471 n/a 04.30.2008 Balboa Main PCB update to rev B
8/10/2019 55471, GS5-GS501Z-RCA-3.0
http://slidepdf.com/reader/full/55471-gs5-gs501z-rca-30 3/11Page 3 55471_97_
Additional Options and Spa-only Dolphin Remote
Power Requirements
Requires PCB Rev B.
System Outputs
1
2
J10
J71
J 1 A
J 2 A
J60 J44
J18
1
1
1
1 1 1 1
J7 J8
EXT RLY SEN A VASEN
J 2 2
AUX F J11
J12
J19
U4
Basic System Features and Functions
Setup 1 (As Manufactured)
(Stereo)
Optional Devices
8/10/2019 55471, GS5-GS501Z-RCA-3.0
http://slidepdf.com/reader/full/55471-gs5-gs501z-rca-30 4/11Page 4 55471_97_
Basic System Features and Functions
Any time you change a DIP Switch, other than A1, you must reset PersistentMemory for your new DIP Switch Settings changes to take effect. If you donot reset Persistent Memory, your system may function improperly.
To reset Persistent Memory: Power down by disconnecting power source from spa. Put a jumper across J43, covering both pins. (See illustration below) Power up by connecting power source to spa. Wait until “ ” is displayed on your panel. Power down again. Remove jumper from J43 (May also move to cover 1 pin only) Power up again.
About Persistent Memory and Time of Day Retention:
This system uses memory that doesn’t require a battery to store a variety ofsettings. What we refer to as Persistent Memory stores the filter settings,the set temperature, and the heat mode.
Persistent Memory is not used for Time of Day. Only models with aSerial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display thetime. However, during power loss to the spa, the system will lose thecorrect time, and reset to 12:00 PM when power is restored.
Power Up Display SequenceUpon power up, you should see the following on the displa
Three numbers in a row, which are the SSID (the SysteID). The third display of these numbers is the Softwar which should match the version of your system. For exthree numbers are , that is a VS511SZ at v
Displayed next is: “ ” (indicating the system is confia heater between 3 and 6 kW) or “ ” (indicating the syconfigured for a heater effectively* between 1 and 3 kW“ ” should appear for all VS models running at 240V“ ” should appear for all VS models running at 120VAas all GS models. (*A heater which is rated at 4 kW atfunction as a 1 kW heater at 120VAC.)
“ ” will appear to signal the start of Priming Mode.
At this point, the power up sequence is complete. Refer toCard for the VS or GS System model of your spa for inforthe spa operates from this point on, including how to adjusDay if using a Serial Deluxe style panel.
C C C
G
SWITCHBANKA
ALBOA INSTRUMENTS,INC.VS500ZP/N 22972 REV D
MADE INU. .ACOPYRIGHT2005
S1
J6 J7 J8J44J6 J22
4
FUSE .3A 250V
FUSE 20A 250V
F U S E 3 A 2 5 0 V
E . G
N D
F4
6 1
89
5
23 6
1
J29J47J50 F7
J 1 7 / 2 6 J20
J1A
J10
J13
J2A
EXT.L
TST AUX. FSEN.A S E . B
V C
W1
W7
J1
J2
W2W3
C
W 4
K23
J1
2 3
J43
2-SPDEXTRLY
J 1
SWITCHBANK AS1
J6
TST
J43
J43 on VS5xxZ and VS300 Series Main Board Shown. J43 on GS5xxZ Series is located in approximately the same position.
G
SWITCHBANKA
P / N 2 2 9 6 4_ B M A D E I N U S . A
.
V S 1 0 0
© 2
0 0 6
S1
3
K5
K4 K1
PUMP
K 2
J7 J8
4
T0.25A 250V
J23 G
C
OZONE
J29
HEATER
J 9
2
TST RST
S EN A S E .
J1
a
o a
F4
J436
C
F5, F3A 250V
J26
J58 J57
LINE
NEUTRALWHTAC
BLKAC
1
J1
SWITCHBANK A
TST RSTJ43J6
J43 on VS100/GS100 Series Main Board Shown.
8/10/2019 55471, GS5-GS501Z-RCA-3.0
http://slidepdf.com/reader/full/55471-gs5-gs501z-rca-30 5/11Page 5 55471_97_
TB1
TR J101 00TR1
G
50
T1
J1
J2
J10
J57
58
J71 1 0 V A
10VA
46
J25
J 2 6
72
J90
J 1 A
J 2 A
J32
J52 51 F6, T30A 480V
AV
ZONE PUMP 1
PT. BLWR/PUMP 2
CIRC. PUMP
K1
K 3
K 4
K6
E
. G N D
J 4 7
G
N
G
N
J29 23
G
N
17/26
K2
K9
J20
N
W2
1
2
4
W1lboa
BALBOA INSTRUMENTS, INC.GS500ZCOPYRIGHT 2007MADE IN U.S.A.
P/N 22015_B
J60 J44
1 1
1
1
1 1 1 1J7 J8
E LTST
J6
EN A VACSEN B
2
J43
UX F
J13
J11
J12
1F2
S1
SWITCHBANK A
K8K5
C9
4
3A 250V
F7 F1 10A 250V
F4, T0.2A 250V
3
B l o w
e r
GS50xZ mode
3.0 kWHeater rated @ 240VJ11 must be Jumpered
3.0kW
SpaLight
Audio Visual
Circ Pump O z o n
e
1 - S
p d P 1
2 - S
p d P 1
Wiring Configuration and DIP Settings
Setup 1 (As Manufactured)
(Stereo)
(optional)
A1, Test Mode OFF A7, J17/26, P1, TE, LT A2, Mode changes allowed
A10, High Amp mode A9, Non-Circ Mode
A5, 2-speed P1
Panel Button Assignments1=J17/262=Pump 1
3=Temp4=Light
Panel Button Positions
1 2 3 41
4 23
1006343
SSID #J11
3.0kWHeater
J12
1
2
3
GS501ZSoftware
Memory Reset
J43
A10, Low Amp mode
A8, Degrees C
A6, 50 Hz
Neutral (Common) AC Connections
Special AC Connections
Line AC Connections
10 Volt Connections
Relay Control Wires
Wiring Color Key
Typically Line voltage
Typically Line voltage for 2-speed pumps
Neutral (Common)
Ground
Note flat sides in connector
Board Connector Key
1
2
3
4
WARNING:Main Power to system should be turned OFF BEFORE adjusting DIP switches.WARNING:Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)
HIPot Testing Note:Disconnect slip terminal with greenwires from J90 prior to performingHiPot test. Failure to disconnect maycause a false failure of the test.Reconnect terminal to J90 aftersuccessful completion of HiPot test.
8/10/2019 55471, GS5-GS501Z-RCA-3.0
http://slidepdf.com/reader/full/55471-gs5-gs501z-rca-30 6/11Page 6 55471_97_
Base Model GS501Z
DIP Switches and Jumpers Definitions
Jumper KeyJ11 If using 3kW or higher wattage heater, jumper can be set in either position, but may perform better on Pins 1 and 2.
If using 2.5kW or lower wattage heater, jumper must be set on 1 Pin only.J12 Factory set. DO NOT MOVE.
Jumper must be on Pins 1 and 2 for GS51xZ/GS52xZ/GS5xxSZ/GS5xxDZ software.Jumper must be on Pins 2 and 3 for GS50xZ software.
J43 When jumper is placed on 2 pins during power-up, system will reset persistent memory.Leave on 1 pin only to enable persistent memory feature.
SSID 100 63 43
WARNING:Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components.Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.Contact Balboa if you require additional configuration pages added to this tech sheet.
A3: OFF
Panel Button Positions
Panel Button Assignments
A3:ON
A7: OFF
A7:ON
1
1 2 3 4
2 3 4
1
4 23
1=J17/262=Pump 1
3=Temp4=Light
1=Pump 12=Light
3=Temp Down4=Temp Up
Aux=J17/26
A
A
DIP Switch Key A1 Test Mode (normally OFF) A2 “ON” position: Standard mode only “OFF” position: Std/Ecn/Sleep mode changes allowed A3 “ON” position: use Mini Panel * “OFF” position: use Digital Duplex or Light Duplex panel A4 Aux Freeze (must be OFF) A5+A9 Pump 1 speeds and Circ Modes:
A5 A9 Circ Mode Pump 1 SpeedOFF OFF Non-circ 2-speedON OFF Circ "acts like Pump 1 low" (filters/polls/ect) 1-speedOFF ON 24 hours with 3°F shut-off 1-speedON ON 24 hours with 3°F shut-off 2-speed
A6 “ON” position: 50Hz operation “OFF” position: 60Hz operation A7 “ON” position: Button layout will be: Pump 1, Light, Temp Down, Temp Up with J17/26 on 1-button Aux panel ** “OFF” position: Button layout will be: J17/26, Pump 1, Temp, Light A8 “ON” position: temperature is displayed in degrees Celsius “OFF” position: temperature is displayed in degrees Fahrenheit A10 “ON” position: heater is disabled while any high-speed pump or blower is running (low amperage mode) “OFF” position: heater can run while any/all high-speed pumps or blowers are running (high amperage mode)* Panels with button layout are not compatible when either A3 or A7 is ON.** J2 panel connector on Main Board must be a 6-pin connector. IR Receiver is not compatible.
Alert:
Blower or 1-speed Pump 2 isrequired, connect to J17/26.For no Blower and no Pump 2,use GS500Z or GS515Z.
8/10/2019 55471, GS5-GS501Z-RCA-3.0
http://slidepdf.com/reader/full/55471-gs5-gs501z-rca-30 7/11
8/10/2019 55471, GS5-GS501Z-RCA-3.0
http://slidepdf.com/reader/full/55471-gs5-gs501z-rca-30 8/11Page 8 55471_97_
Electrical Service Configuration Options
TB1
HTR2 J101 00HTR1
G
50
T1
1
J10
57
J58
J71 0 V A 10VAC
46
J25
J 2 6
J72
J90
J 1 A
J 2 A
J32
J52 5 F6, T30A 480V
AV
ZONE PUMP 1
PT. BLWR/PUMP 2
CIRC. PUMP
K1
K 3
K 4
6
E . G N D
4 7
G
G
N
G
N
29 J23
G
N
J17/2
2
K9
J20
W2
1
2
3
4
W1o
BALBOA INSTRUMENTS,INC.GS500ZCOPYRIGHT2007MADE INU.S.A.P/N22015_B
J60 J44
J18 1
1
1
1 1 1 17 J8
EXTRLYTST
J6
SENA VACENB
J 2 2
J43
AUXF
J13
J11
J12
J19F2
S1
WITCHBANK A
8K5
C9
U4
F3A 250V
F7 F1 10A 250V
F4, T0.2A 250V
b
3
L1
N
L3
L2
3-Phase Service, TN and TT Electrical Systems5 Wires (3 Lines + 1 Neutral + 1 Protective Earth)
Completely remove the white wire from J26 and J32, or J25.
To an optionalfuse-protectedexpansion board.
Completely remove the blue wire from J28 and J58.
IMPORTANT - Service MUST include a neutral wire, with a line to neutral voltage of 230VAC.
Protective Earth wire (Green/Yellow) must be connectedto system ground terminal as marked.
The heater runs on service line L1. All main-board equipment run on service line L3. Addtional equipment, such as expansion boards, run on service line L2.
If an expansion board is installed, black wire must connectto J28 (Line L2) only.
Systems using only 1 DIP switch (A10) for heat disable: DIP Switch A10 must be OFF.Systems using multiple DIP switches for heat disable: Refer to system Hot Sheet DIP Switch Definition page and set both switches shown in Table 1 to ON positions.
OPTIONAL
Systems with PCB Rev B Only
NOTE:Not all GS5xxZ systems can support 3-Phase.3-Phase requires System PCB Rev B.If using an expansion board, the board must have fuse-protection.
8/10/2019 55471, GS5-GS501Z-RCA-3.0
http://slidepdf.com/reader/full/55471-gs5-gs501z-rca-30 9/11
8/10/2019 55471, GS5-GS501Z-RCA-3.0
http://slidepdf.com/reader/full/55471-gs5-gs501z-rca-30 10/11Page 10 55471_97_
Ozone Connections
TB1
G RBW
J50
J57
J58
J25
J90
J28
J32
J52 J51 F6, T30A 480V
AV
OZONE PUMP 1
CIRC. PUMP J 4 7
G RBW
G
R
B
W
J29 J23
W2
1
2
F4, T0.2A 250V
Audio Visual
Circ Pump
2 -
S p d
P 1
Empty Black or Brown Line Conductor
Balboa Ozone connector configuration for 230VAC 50Hz:L
NEmpty
White or Blue Neutral Conductor
Flat sides of sockets as shown
Not usedLine - Black or Brown conductor
Not usedNeutral - White or Blue conduct
Note: A special tool is required to remove the pins from the connector body once they are snapped inplace. Check with your Balboa Account Manager for information on purchasing a pin-removal tool.
8/10/2019 55471, GS5-GS501Z-RCA-3.0
http://slidepdf.com/reader/full/55471-gs5-gs501z-rca-30 11/11