77
476 5. Sample preparation Contents GENERAL CATALOGUE EDITION 17 Sampling 477 Samplers, Solids 477 + Samplers, Liquids 481 Grinding 487 Jaw breaker 487 + Mills 487 + Mortars 508 Sieving 510 Sieve shakers 510 + Test sieves 514 + Sample divider 520 Mixing, Homogenisation 522 Dispersers 522 + Ultrasonic homogenizers 532 + Homogenisers 541

5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

Embed Size (px)

Citation preview

Page 1: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

476

5. Sample preparationContents

GENERAL CATALOGUE EDITION 17

Sampling 477Samplers, Solids 477 + Samplers, Liquids 481

Grinding 487Jaw breaker 487 + Mills 487 + Mortars 508

Sieving 510Sieve shakers 510 + Test sieves 514 + Sample divider 520

Mixing, Homogenisation 522Dispersers 522 + Ultrasonic homogenizers 532 + Homogenisers 541

Page 2: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

477

5. Sample preparationSampling/Samplers, Solids

GENERAL CATALOGUE EDITION 17

E & OE.

Pigment LanceFor pigments and pastes and agglomerating bulk goods.

- With half-open flute 50% for slightly adhesive products- With one-quarter-open flute 25% for less adhesive products

1Bürkle

Capacity Fluteopening

Length Dia. PK Cat. No.

ml mm mm14585312179480273

25%50%25%50%25%50%

300300600600900900

303030303030

111111

9.303 7109.303 7119.303 7129.303 7139.303 7149.303 715

1

Disposable Samplers DispoSampler NEW!NEW!

In numerous situations, rapid and contamination-free samples have to be taken.DispoSamplers are perfect for this application. They are individually packed and alwaysready to use. Avoid expensive decontamination or cleaning of soiled samplers.Gamma sterilised versions are also available.LiquiDispoFor liquids with low viscosity up to 10000cP.MicroDispoFor semi-solid goods up to 0.5mm diameter.ViscoDispoFor high viscous media up to 100000cP.PowderDispoDisposable sampler for taking a cross sectional sample from within a bulk powder.

2Bürkle

Type Length Capacity Material PK Cat. No.cm ml

LiquiDispoLiquiDispoMicroDispoViscoDispoViscoDispoPowderDispo

5001000500500

1000620

10019010

100190100

PE-HDPE-HDPE-HDPE-HDPE-HDPE-HD

202020202020

9.303 7209.303 7229.303 7289.303 7329.303 7349.303 736

2

Jars - please see page 23

Page 3: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

478

5. Sample preparationSampling/Samplers, Solids

GENERAL CATALOGUE EDITION 17

E & OE.

Zone samplers, Multi/All-layer/Jumbo, steel V4A or aluminium NEW!NEW!

For sampling bulk goods of all types. Available in various different lengths and materials:

Multi-sampler:With several closed chambers for multi-target samples from several preset sample depths. Available in stainless steelV4A/PTFE, stainless steel V4A/V4A or Aluminium. Tube diameter: 25mm.All-layer-sampler:With open chambers for cross-sectional sampling through all layers of the sample. Emptied via the open tube end of thecollector. Available in stainless steel V4A or aluminium. Tube diameter: 25mm.Jumbo-sampler:Generally as the All-layer-sampler with open tube end. Tube diameter is 50mm making the sampler very good forcoarser granule samples and large sample volumes. Available in stainless steel V4A or aluminium.

Easy emptying with the emptying device.

1 2

Bürkle

1

2

Type Material Length Imm.depth

No. of chambers

Capacity PK Cat. No.

mm mm mlMulti-SamplerMulti-SamplerMulti-SamplerMulti-SamplerMulti-SamplerMulti-SamplerCross-section samplerCross-section samplerCross-section samplerCross-section samplerCross-section samplerCross-section samplerJumbo samplerJumbo samplerJumbo samplerJumbo samplerJumbo samplerJumbo sampler

V4A/PTFEV4A/PTFEV4A/PTFEV4A/V4AV4A/V4AV4A/V4AAnodized aluminiumAnodized aluminiumAnodized aluminiumV4A/V4AV4A/V4AV4A/V4AAnodized aluminiumAnodized aluminiumAnodized aluminiumAnodized aluminiumV4A/V4AV4A/V4A

550850

1500550850

1500550850

1500550850

1500850850

1500250015002500

430710

1355430710

1355430710

1355430710

1355710710

1355235513552355

335335335335335757

14171714171770

13026070

130260390880

17002900650910

111111111111111111

9.303 8609.303 8629.303 8647.631 2017.653 1249.303 8669.303 8759.303 8769.303 8776.232 1906.234 5989.303 8656.240 9569.303 8789.303 8799.303 8837.625 8846.236 850

Zone sampler, accessory cleaning brush, PVC/stainless steel

For basic cleaning of Zone samplers.

3

Length Dia. PK Cat. No.mm mm60010001000

252550

111

9.303 8809.303 8849.303 885

3

Emptying device, stainless steelEmptying zone samplers were often a matter of patience and a steady hand. Now itseasier and faster with Bürkles emptying device. just lay the zone sampler onto thestainless steel stand, adjust the funnels along the sample chambers, and, after turning the sampler, the media willdirectly flow into the containers below. Quality materials ensure that the sampler is autoclavable.

4Bürkle

Description PK Cat. No.

Emptying device 1 6.236 050

4

Page 4: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

479

5. Sample preparationSampling/Samplers, Solids

GENERAL CATALOGUE EDITION 17

E & OE.

Sampler QuickPicker, Stainless steel V4A or PP NEW!NEW!

Suitable for removing bulk materials from sacks or large bags and depositing directly intosample bottles. Simple to use and clean. Crevice-free to prevent sample residues causingcross-contamination which could affect subsequent sample results.Complete with cleaning brush and two 250ml sample bottles.

1

Bürkle

Material Length Imm.depth

Capacity PK Cat. No.

mm mm mlPPV4A

500500

300300

7575

11

6.205 4589.303 850

1

Sample bottles for QuickPicker Sampler2Bürkle

Type Capacity PK Cat. No.ml

PE-LD, transparentPP, transparent

250250

11

9.303 8549.001 062

2

Sampler Tubus, AISI 316 stainless steel, according to ISTA

Sampler for free flowing, bulk goods up to approx. 1cm diameter. This makes it possible,for example, to remove hazel nuts, blends of tea, grain or similar items from large sacks.Operation: Insert Tubus into a sack to the desired sampling depth, while keeping the collection tube closed using yourhand. When you take away your hand, the sample flows directly through the open tube into the container or samplingbag beneath it.

- choice of 2 lengths, 40cm and 80cm- also for coarse-grained bulk goods- AISI 316 stainless steel- corresponds to ISTA standard for seed lengths of 10mm and 20mm

3

Bürkle

Type Length Dia. PK Cat. No.mm mm

TubusTubus

400800

4040

11

6.200 3946.204 492

3

Sampler Milk Powder, AISI 316 stainless steel, conforms to standards of DIN andIDFMilk powder collector made of AISI 316 stainless steel, sterilisable. Developed especiallyfor milk powder samples, conforms to standards of DIN and IDF (Int. Dairy Federation).The collector is inserted into bags or casks and the sample is removed using a semi-circular profile lance.

4

Bürkle

Type Length Imm.depth

Capacity PK Cat. No.

mm mm mlMilky 480 385 150 1 6.051 629

4

Spatula SteriPlast, PS, sterile NEW!NEW!

White spatula for powder, granules, pastes. With fixed handle, ideal for taking samplesfrom sacks, containers or the manufacturing process. The rigid tip allows caked surfacesto be penetrated.Sterilised, single packed.

5Bürkle

Length Imm.depth

Capacity PK Cat. No.

mm mm ml228 152 36 10 6.059 018

5

Page 5: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

480

5. Sample preparationSampling/Samplers, Solids

GENERAL CATALOGUE EDITION 17

E & OE.

Sampling scoops and spoons, PS, sterileWhite. For disposable use. Individually packed.

1 2Bel-Art Products

Type Capacity PK Cat. No.ml

ScoopScoopScoopSpoonSpoonSpoonSpoon

601252501,232,464,9314,79

1111111

9.150 4619.150 4629.150 4639.150 6399.150 6409.150 6419.150 642

Other sampling devices are available on request.

1

2

Sample bags SteriBag, PE, sterile NEW!NEW!

Sterile, PE, liquid sample bags. For samples from chemistry, pharmaceutical, medical,food technology applications etc.

Type A: Without write-on panelType B: With write-on panel.

3Bürkle

Type Capacity Width Length PK Cat. No.ml mm mm

ABABABABABAB

6060

180180540540720720810810

16501650

76767676

114114140140114114178178

127127178178229229229229305305305305

500500500500500500500500500500250250

9.404 1149.404 1199.404 1159.404 1209.404 1169.404 1219.404 1179.404 1229.404 1189.404 1236.223 0946.223 093

3

Control seals for sampling close-it® NEW!NEW!

Printed or plain. close-it® is an aluminium backed, vapour-proof adhesive label withextremely strong adhesion. Sacks, boxes etc. which have been pierced with samplers canbe hermetically resealed. Can even adhere to slightly moist or dusty sacks coated with fine powders, e.g. plaster, flouretc.

close-itfoodThe strength of the adhesive is almost as powerful as that of the original, the million-times proven close-it from Bürkle,and also ensures the necessary success when resealing sample openings, as it reliably prevents products from escapingafter sampling. The adhesive complies with the European guidelines for foodstuffs. Just like the original, close-it foodhas a barrier layer of aluminum foil. This means that close-it food is suitable for sampling foodstuffs, pharmaceuticals,cosmetics, food additives - in short, for all applications in which the product must not be contaminated by contact withthe adhesive.

4 5 6Bürkle

Type Colour Description PK Cat. No.

PrintedPrintedPrintedPrintedPrintedPlainRollerPrintedPrintedPrintedPrintedPrintedPlainRollerPlainPrintedPlainPrintedclose-it tapeclose-it tapeclose-it tape foodclose-it tape food

redgreenyellowblueblackwhite

redgreenyellowblueblackwhite

whiteredwhitewhite

Standard 95 x 95mmStandard 95 x 95mmStandard 95 x 95mmStandard 95 x 95mmStandard 95 x 95mmStandard 95 x 95mm95 x 95mmMaxi 150 x 150mmMaxi 150 x 150mmMaxi 150 x 150mmMaxi 150 x 150mmMaxi 150 x 150mmMaxi 150 x 150mm150 x 150mmFood 95 x 95mmFood 95 x 95mmFood 150 x 150 mmFood 150 x 150 mmRoll 95mmRoll 150mmRoll 95mmRoll 150mm

500500500500500500

1250250250250250250

1500500250250

1111

9.303 9109.303 9119.303 9129.303 9139.303 9149.303 9159.303 9199.303 9809.303 9819.303 9829.303 9839.303 9849.303 9859.303 9899.303 9866.228 2559.303 9909.303 9919.303 9929.303 9939.303 9949.303 995

4

5

6

Page 6: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

481

5. Sample preparationSampling/Samplers, Solids-Samplers, Liquids

GENERAL CATALOGUE EDITION 17

E & OE.

Anti-tamper seal seal-it, self-adhesive, roll NEW!NEW!

If a container opening is closed with seal-it, then the container cannot be openedwithout destroying the seal-it label. seal-it is additionally provided with severalcross-perforations which immediately tear when manipulated like a motorcar tax disc. seal-it can be used to securelyseal bottles, sample bags, sacks, specimen bags, envelopes, etc. The white labelling field on seal-it can be written onwith all conventional writing tools with, for example, contents information, sampling date, name of operator, etc.- Clear identification via numbers in sequence- Integrated control label with the same number, for accompanying documents- Format 178mm long, 30mm wide- Tear-off perforation for each label

1Bürkle

Type PK Cat. No.

seal-it 500 7.622 477

1

Sampler Silo drill, aluminium or stainless steel NEW!NEW!

Designed for sampling powders, granulates or semi-solids from silos and vehicle tankers.When bulk goods are transported over a long distance (e.g. by HGV) the material canseparate out, so if a sample is then taken only from the surface the result may not be representative. With the Silo drilla sample can be drawn from deeper levels. The Silo driil is screwed manually into the material and only opened once atthe required sample depth. Depths of up to 2.5m can be reached by using extension rods. The Silo drill is not onlysuitable for silos, but also but can also be used in numerous bulk goods containers in the pharmaceutical, chemical,foodstuffs and semi-luxury goods sectors.Spiral diameter: 90mm, chamber: diameter 40mm, capacity 400ml.

2 3

Bürkle

Type Length PK Cat. No.mm

Silo drill, aluminiumSilo drill, V4AExtension rods

150015001000

111

9.303 8589.303 8689.303 859

2

3

Wide mouth bottles please see page 46.

Liquid sampler MiniSampler, PETaking samples is quick, easy, clean and practical.With the MiniSampler, the sample liquid only comes into contact with the suction hoseand the sample bottle. Cross contamination is largely prevented. Bottles can be tightly sealed immediately after thesample is taken with a tamper-evident cap.The single use, PE suction hose can be quickly replaced, ensuring that samples are never contaminated. A new hosecan be used for each sample if required. Because of its small diameter (8mm) and flexibility the hose can reachsampling areas that are otherwise inaccessible.

Accessories:Supplied with ten 100ml PE bottles, 10m of PE suction hose (6 x 8mm), 1 hose cutter , 1 stainless steel hose weightand 20 seal-it safety seal labels in a carrying case.

4Bürkle

Type PK Cat. No.

MiniSampler 1 9.303 970

4

Page 7: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

482

5. Sample preparationSampling/Samplers, Liquids

GENERAL CATALOGUE EDITION 17

E & OE.

Sampler ProfiSampler, aluminium NEW!NEW!

Vacuum-operated sample collector for sampling liquids in drums, tanks, road tankers,railway wagons, ships, lakes, ground water.- can be supplied with optimized, straight suction tube for simpler sampling.- transport case for tidy transport and disposal- filling level control, automatic return flow and overfill protection by built-in venting valve.- optimized draw volume: 200ml, suction pressure 0.5 bar and suction depth down to 4m of water.- always check the chemical resistance of parts coming into contact with the sample.wear protective clothing!

ProfiSampler AluminiumComprises: aluminium vacuum pump, with feet, venting valve and GL45 bottle thread, 1 x 500ml glass bottle, 5 x 220mm long, conductive, black PA suction tubes, 1 tubing cutter, 1 hose weight made of grade 304 stainless steel,24 sample labels, 24 seal-it bottle seals, earthing cable.

1Bürkle

Type PK Cat. No.

ProfiSampler AluminiumPA suction tubes, black, 220cm length, pack of 10 pieces

110

6.225 6226.226 207

1

Sampler Uni-Sampler "Ex", for sampling class A1 flammable liquids

Specially developed for sampling class A1 flammable liquids (e.g. benzene, petrol). Glassbottles and tubing electrically connected and grounded via an earthing cable. The "Ex"sampler was developed in cooperation with Gütegemeinschaft Tankschutz e.V.

Operation:1. Earth the Uni-Sampler. 2. Lower the suction hose to the desired depth. 3. Attach the adapter to the sample bottle. 4. Generate vacuum with the hand pump and collect sample. 5. Remove the filled sample bottle, seal and label.

- PTB approval D-333-009 618/00- Comprises 4m of sample tubing, glass sample bottle, manual vacuum pump and earthing cable in carry case

2

Bürkle

Type PK Cat. No.

Uni-Sampler "Ex" 1 9.303 831

2

Chemistry dippers, PP, with rod handleSuitable for aggressive liquids. With beaker and PP rod handle.

3Bürkle

Capacity Length* Stemdia.

PK Cat. No.

ml mm2506001000

100010001000

202020

111

9.303 8409.303 8429.303 844

* Stem

3

Sampling system TeleScoop NEW!NEW!

TeleScoop is a versatile sampling system with exchangeable tools for a wide range ofapplications. The tools (angular beaker, pendulum beaker, bottle holder, stainless steelbeaker and dip net) are attached to the rod by a practical snap-in joint. Ideal for sampling from baths, tanks, shafts,open water courses etc. Sampling depths down to 6m can be reached with the adjustable telescopic aluminum rod.Catch net for taking solid and organic samples from water courses.

Bürkle

Telescopic rods TeleScoop, aluminiumAluminium, with red plastic fittings. New corrugated construction prevents the barsrotating during retrieval of a sample. With screw clamps and end-stops to prevent thesections sliding apart.

4Bürkle

Length PK Cat. No.m0,65 - 1,200,95 - 2,801,25 - 2,501,15 - 3,001,65 - 4,501,75 - 6,00

111111

9.303 8009.303 8019.303 8029.303 8049.303 8069.303 807

4

Page 8: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

483

5. Sample preparationSampling/Samplers, Liquids

GENERAL CATALOGUE EDITION 17

E & OE.

Industrial dip samplers, sample beakers, angled for TeleScoopWith individually variable angle adjustment.

1Bürkle

Capacity Material PK Cat. No.ml50010002000

PPPPPP

111

9.303 8109.303 8129.303 814

1

Pendulum beaker for TeleScoop, PPFor industrial dip samplers. Automatically swings into a vertical position. Ideal for narrowshafts.

2Bürkle

Capacity Material PK Cat. No.ml50010002000

PPPPPP

111

9.303 8209.303 8229.303 824

2

Bottle holder for TeleScoop, PP/PAFor industrial dip samplers. Holds bottles up to max. 88mm diameter. Suitable for plasticand glass bottles. With universal quick-action clamping strap.

3Bürkle

Type PK Cat. No.

Bottle holder 1 9.303 830

3

Dip sampler for TeleScoop, stainless steelFor pasty or powdery materials

- with lip for scraping- sterilisable

4Bürkle

Capacity PK Cat. No.ml1000 1 9.303 846

4

Page 9: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

484

5. Sample preparationSampling/Samplers, Liquids

GENERAL CATALOGUE EDITION 17

E & OE.

behrotest® water samplersFor sampling from the water surface.Adjustable clamping device and end rod made of stainless steel, with choice of samplecontainer as indicated. For sampling in accordance with DIN 38409 to H14/AOX a 1 litre borosilicate beaker is required.With 3-part handle, which is continuously adjustable between 1 and 3.75 m. Ideal for use at sites which are difficult toaccess.

1Behr

Type Description PK Cat. No.

PB 1000PF 1000PP 1000PT 1000PV 1000

With boro. glass beakerWith dispensing bottleWith PP beakerWith PTFE beakerWith stainless steel beaker

11111

9.920 6309.920 6319.920 6329.920 6339.920 634

1

Catch nets for TeleScoop NEW!NEW!

Ideal for sampling from basins, tanks, shafts, open waters etc. The telescopic aluminiumrods TeleScoop allow sampling up to 6m depth.- For industries and water treatment- Mesh width: 2mm up to 5mm- Depth catch, net depth: 250mm

2 3Bürkle

Type Material Dimensions(W x D)

PK Cat. No.

mmSurface catch netDepth catch net

PVC / PA

PP / PA

310 x 280

190 x 430

1

1

9.303 828

9.303 829

2

3

Sampler VampireFor field sampling of liquids.Portable, peristaltic tubing pump for all liquids. Ideal for sampling from drums, tanks,wells, water separators, sewage installations and treatment plants.- Simple cleaning, liquids pumped only come into contact with tubing- With rechargeable battery and charger- Sample taken directly into specific sample bottle- Maximum depth that samples can be withdrawn: 5m- Also suitable for contaminated or particle-laden liquids- Good chemical resistance- High flow rate up to 2.0L/min.

Supplied with bottle basket, driving unit, battery charger, peristaltic pump and 5m of PE suction tubing.

4Bürkle

4

Type PK Cat. No.

Vampire sampler, completeExtension tubing, PE, 5mWide-mouth sampling bottle, 250mlWide-mouth sampling bottle, 500mlBottle holder for 500ml bottle

15111

9.303 8519.303 8399.303 8549.303 8559.303 845

Page 10: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

485

5. Sample preparationSampling/Samplers, Liquids

GENERAL CATALOGUE EDITION 17

E & OE.

Sampler LiquiSampler, PTFE/FEP or PPDIN 53242. For liquids. Choice of construction. PTFE/FEP for contamination-freesampling, or transparent PP. Practical push button, single-handed operation. Suitable forpoint, cross-sectional, and bottom sampling. Ideal for sampling from open and closed drums, kegs, tanks, silos, watersources (ponds, lakes, streams, rivers). Suitable for all commercial kegs and drums with openings of at least 25mmdiameter. All surfaces are non-porous and crevice-free preventing accumulation of dirt. Only round-profile screwthreads,suitable for food hygiene applications, are used. Simple to dismantle and clean.

1Bürkle

Material Length Dia. PK Cat. No.mm mm

PTFE/FEPPTFE/FEPPP, transparentPP, transparent

1000200010002000

25252525

1111

9.303 9509.303 9519.303 9559.303 956

1

Sampler ViscoSampler, PTFE/FEP or PP

Ultra-pure sampler with powerful suction for viscous substances.Choice of construction. PTFE/FEP or PP.Specially designed for viscous substances, such as lime water, slurries, wet clay and soil samples, sediment, oils,emulsions and creams.The filter flask sucks up and discharges the material. All surfaces are non-porous and crevice-free, preventing dirtaccumulation. Only round-profile threads, suitable for food hygiene applications, are used. Allow easy dismantling andcleaning.

2

Bürkle

Material Length Dia. PK Cat. No.mm mm

PTFE/FEPPTFE/FEPPPPP

1000200010002000

25252525

1111

9.303 9609.303 9619.303 9659.303 966

2

Page 11: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

486

5. Sample preparationSampling/Samplers, Liquids

GENERAL CATALOGUE EDITION 17

E & OE.

Liquid samplers, vessels and bottlesAccording to DIN 51750 pt. 2

Dipping VesselFor sampling liquids from tanks, lorry tankers, etc. Made for Ex-use or stainless steel V2A. 1L capacity, 75mm diameter,400mm high. Without lowering cable.Operation: Lower vessel into liquid. Bottom and cap valves open automatically. Liquid flows through the vessel. Thevalves close at the target depth, and the desired sample can be collected.

Dipping bottle EXFor sampling flammable liquids.For sampling group A mineral oil products, VbF Hazard Classes AI and AII. Made from brass that do not produce sparks,75mm diameter, 385mm high, weight 3kg. Without lowering cable.Operation: 1. Lower bottle into liquid. 2. Pull the cable when the target spot has been reached and the stopper opens.3. Sample flows in. 4. Pull up dipping bottle and remove sample.Use an electrically conductive, manually operated reel and lowering cable or chain.

Dipping bottleFor sewage disposal plants, sludge and water samples. Nickel-plated brass frame with glass sample bottle. 1000mlcapacity, 125mm diameter, 330mm high, weight 3.1kg. Without lowering cable.Operation: 1. Lower bottle into liquid. 2. Pull cable when target depth is reached and open stopper. 3. Sample flows in.4. Pull bottle back up and remove sample.

Immersion CylindersFor target spot and bottom samples of mineral oil products. Made of nickel-plated brass.Heavy, robust design (4.1kg).Without lowering and pull cablesTarget spot sample: 1. Immersion cylinder is lowered in the tank to be sampled by the manually operated reel. 2. Theseparate pull cable is used to open the valve when the target spot is reached and the sample then enters the immersioncylinder.Bottom sample: 1. Lower the immersion cylinder to the bottom. 2. The weight of the immersion cylinder opens thevalve automatically when the bottom is reached and the sample then enters the immersion cylinder.

Target immersion cylinderWith the Target immersion cylinder, liquid samples can be taken from a particular point. The immersion cylinder islowered on a strong and sealed tube. When the target has been reached, a valve at the tube end is opened. This ventsthe immersion cylinder and fills it with the sample. The immersion cylinder is pulled up and emptied via the screwthread. Weight 1.5kg. With 5m venting tube. Upper body unscrews for easy cleaning.

Mini immersion cylinderFor sampling liquids in narrow places where access is difficult. Can also be used in curved dipping tubes and barrelswith narrow openings. Capacity 50ml, 30mm diameter, height 180mm, weight 280g. Without lowering cable. Upperbody unscrews for easy cleaning.

1

23456

Bürkle

Type PK Cat. No.

Dipping vessel, nickel-plated brassDipping vessel, stainless steel V2ADipping bottle (Ex)Dipping bottleImmersion bombTarget immersion cylinderMini immersion cylinder

1111111

9.303 9359.303 9369.303 9379.303 9389.303 9397.623 9349.303 933

1

9.303 935

2

9.303 937

3

9.303 938

4

9.303 939

5

7.623 934

6

9.303 933

Accessories for liquid samplers, vessels and bottles7Bürkle

7

Description PK Cat. No.

Manual cable reel, PP green, without cableManual cable reel, black PP, electrically conductive, without cableManual cable reel Ex, black with grounding cable, without cableCable, V2A steel conductiveAISI 304 stainless steel lowering cable/PTFE-coated, length 10m

11111

6.200 2639.303 9416.234 8159.303 9436.087 044

Page 12: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

487

5. Sample preparationGrinding/Jaw breaker-Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Jaw Crusher, BB 51Benchtop model Jaw Crusher for the rapid and gentle, coarse and preliminary sizereduction of hard, brittle and ductile materials. Continuous digital gap width adjustmentwith scale, enhanced ultimate fineness.

Features:- Feed size up to 35mm (feed opening 40mm)- Throughput/charge: single items, charges to 1000ml- Dimensions: 360mm x 580mm x 510mm (WxDxH)- Weight approx. 80kg- Supply requirements: 230V, 50Hz

1Retsch

Type Material PK Cat. No.

BB 51BB 51BB 51BB 51

Stainless steelTungsten carbideZirconium oxideManganese steel

1111

9.739 0759.739 0769.739 0779.739 078

1

Jaw Crushers, BB 100, BB 200, BB 300For rapid and gentle coarse grinding and crushing of hard, brittle and tough materials.Continuous gap adjustment with scale and zero-point adjustment for wearcompensation. Excellent performance with enhanced ultimate fineness, robust construction, fitted with quick-releasehopper, receiver with safety switch and casing. Standard model is supplied with manganese steel breaking jaws. Modelswith jaws made of stainless steel or tungsten carbide are available, details on request.

Features:- high throughput- continuous gap width adjustment- braking motor with safety switch- ultimate fineness approx. 1 to 40mm- easy cleaning of grinding chamber- Supply requirements 400 V 3-ph, 50 Hz

2Retsch

2

Type Feed sizeup to

Dimensions(W x D x H)

Weight PK Cat. No.

mm mm kgBB 100BB 200BB 300

5090

130

320 x 800 x 960450 x 900 x 1160670 x 1450 x 1600

137300700

111

9.739 0989.519 1209.739 093

Ultra Centrifugal Mill ZM 200Extremely rapid and gentle size reduction of soft to medium-hard and fibrous materials.Ideal for grinding, e.g., chemicals, food and feeds, washing powder, plastics, fertilizers,pharmaceutical raw materials and finished products. Also suitable for cryogenic grinding.

Features:- Gentle on the material thanks to 2-step rotor/screen system- New Powerdrive ensures higher performance with increased torque, even with temporary overloads- Wide speed range, adjustable from 6000rpm to 18000rpm- Patented cassette system for maximum sample recovery and easy cleaning- Defined final fineness due to ring sieves sieves with aperture sizes from 0.08mm to 10mm- For sample volumes from a few mls to 4.5L- Comfortable safety housing with automatic cover closure- Feed size up to 10mm- Ultimate fineness to approx. 40µm- Throughput/charge up to 900/4500ml (with cyclone)- Dimensions (W x H x D) 410mm x 365mm x 515mm- Weight: approx. 38kg- Supply requirements 230V, 50/60Hz approx. 1300 W

Supplied with: ZM 200 with 900ml cassette. Please order rotor and ring screens separately. Alternative rotors and ringsieves (e.g. for heavy metal-free grinding) are available on request.

3Retsch

Type PK Cat. No.

ZM 200 1 9.738 970

3

Page 13: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

488

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Accessories for Ultra Centrifugal Mill ZM 2001Retsch

1

Description PK Cat. No.

Rotor, stainless steel, 6 teethRotor, stainless steel, 12 teethRotor, stainless steel, 24 teethRing screen, trapezoid holes 0.08mmRing screen, trapezoid holes 0.12mmRing screen, trapezoid holes 0.20mmRing screen, trapezoid holes 0.25mmRing screen, trapezoid holes 0.50mmRing screen, trapezoid holes 0.75mmRing screen, trapezoid holes 1.00mmRing screen, trapezoid holes 1.50mmRing screen, trapezoid holes 2.00mmRing screen, round holes 3.00mmRing screen, round holes 4.00mmRing screen, round holes 5.00mmRing screen, round holes 6.00mmCyclone, with passage container and holder, with 5L collectorCyclone, with passage container and holder, with 3L collectorReplacement grinding set for the grinding of very small quantities of material, 8 tooth push-fit rotor, labyrinth disk and 50mFeeder kit, DR 100, drive unit for 220-240V, 50Hz, with feed attachment, with 40mm push-fit feed chute, funnel and stand

1111111111111111111

1

9.739 0649.739 0659.739 0669.738 9729.738 9739.738 9749.738 9759.738 9769.738 9779.738 9789.738 9799.738 9809.738 9819.738 9829.738 9839.738 9849.738 9859.738 9869.738 987

9.738 971

Rotor Beater Mills SR 200/SR 300For batch and continuous coarse, fine and ultra-fine grinding, as well as for thedeagglomeration of dry, soft, medium-hard, organic and inorganic materials. The SR300 achieves a larger throughput with higher product fineness due to the higher rotor speed and drive capacity than theSR 200. Grinding and sieve inserts are easily interchangeable.

Specifications:- Feed size up to 15mm- Ultimate fineness: < 0.08mm- Supply requirements: 400V, 50Hz 3-ph.

Items supplied: Mill with rotor and 5L stainless steel receiver including, filter tubing. SR 300 is also available with baseframe. Sieves for sieve frames and grinding assemblies are available on request.

2Retsch

Type PK Cat. No.

SR 200 for 400 V 50 Hz 3-ph., grey cast ironSR 300 for 400 V 50 Hz 3-ph., stainless steel

11

9.739 0819.738 905

2

Accessories for Rotor Beater Mills SR 200/SR 300Retsch

Type PK Cat. No.

Base frame 360°, stainless steelRing sieve, Conidur holes 0.25mmRing sieve, Conidur holes 0.50mmRing sieve, Conidur holes 0.75mmRing sieve, Conidur holes 1.00mm

11111

9.738 9099.738 9149.738 9159.738 9169.738 917

Page 14: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

489

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Cross Beater Mill SK 100For simple, rapid grinding of medium-hard and brittle materials, with batchwise orcontinuous operation. Versatile use due to large selection of accessories. Central lockingdevice and motor brake ensure excellent operating safety.

Specifications:- Feed size: up to 15mm- Ultimate fineness: approx. 0.1mm- External dimensions (WxDxH): 560 x 700 x 1150mm (inc. base stand)- Weight approx.: 54kg- Supply requirements: 400V, 50Hz 3-ph.

Supplied with: cross beater mill with cross beater, impact plates, filter tubing for 5L receiver. Receiver and underframe,please order separately. Alternative power supply versions are available, details on request. Accessory base frame kitalso available, details on request.

1Retsch

Type PK Cat. No.

SK 100, hardened steelSK 100, cast ironSK 100, stainless steel

111

9.739 0209.739 0219.739 022

1

Accessories for Cross Beater Mill SK 100Retsch

Type Aperture size

PK Cat. No.

mmBase for SK 100Base screen, trapezoid holesBase screen, trapezoid holesBase screen, trapezoid holesBase screen, trapezoid holesBase screen, trapezoid holesBase screen, trapezoid holes

-0.120.501.002.005.0010.00

1111111

9.738 8119.738 6719.738 9129.738 6609.738 6629.738 6659.738 670

Cutting Mill SM 100/200/300 NEW!NEW!

Rapid and gentle size reduction of bulky, soft, medium-hard, fibrous, elastic andthermally sensitive materials. The most powerful model, the SM 300, is especiallysuitable for cutting heterogeneous mixtures such as household waste, plastic materials, computer and electronic scrap.The mills are also used for organic materials like wood, roots, bones, plants and feed pellets. They can be equipped withvarious rotors and hoppers. The SM 300 features a variable speed which makes it perfectly adaptable to the particularapplication requirements.

Features:- powerful size reduction thanks to 3kW drive with high torque and RES technology (SM 300)- perfect adaptation to application requirements by variable speed from 700rpm to 3000rpm (SM 300)- optimum cutting effects thanks to double acting cutting bars (SM 200, SM 300)- quick and easy cleaning without tools due to fold-back housing with smooth surfaces and push-fit rotor and sieves

(SM 200, SM 300)- defined final fineness due to bottom sieves with aperture sizes from 0.25mm to 20mm- wide range of accessories including various hoppers, collection systems, rotors and sieves

Supplied with:SM 100 with 5L collecting receptacle. Please order rotor, hopper and bottom sieve and base frame (option) separately.SM 200/SM 300 with 5L collecting receptacle, base frame. Please order rotor, hopper and bottom sieve separately.

2Retsch

Specifications SM 100/200/300Feed size: up to 60 x 80mmFinal fineness: 0.25 to 20mmRetractable hopper: -/yes/yesPush-fit rotor: yes/ yes/yesSpeed at 50 Hz: 1500rpm

(SM 300) variable 700 to 3000rpmDrive power: 1.5/2.2/3kWMains connection: 3/N~ 400V, 50Hz

(SM 300) 220-230V, 50/60Hz

Type Dimensions(W x D x H)

Weight PK Cat. No.

mm kgSM 100SM 200SM 300

582 x 700 x 1675576 x 760 x 1675795 x 765 x 1691

7390

160

111

9.739 0699.739 0679.739 083

Further voltages and versions for heavy-metal free grinding on request.

2

Page 15: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

490

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Rotors and Receptacles SM 100/200/300 NEW!NEW!1Retsch

1

Description PK Cat. No.

6-disc rotor stainless steel, with reversible cutting tipsParallel section rotor stainless steelCollecting receptacle, 30L plastic, incl. adapter and filter hoseCollecting unit 250/500ml incl. 2 sample bottles

1111

9.739 0747.900 4279.739 6079.739 608

Hoppers for Cutting Mill SM 100 NEW!NEW!

Retsch

Description PK Cat. No.

Base frame with wheelsStandard funnel for cutting millLong stock hopper

111

7.900 4267.900 4289.739 070

Hoppers for Cutting Mill SM 200/300 NEW!NEW!2Retsch

2

Description PK Cat. No.

Universal hopper with plastic plungerLong stock hopper with wooden plunger

11

9.739 0719.739 072

Cyclone-suction-combination for cutting mill SM 200/300 NEW!NEW!

Retsch

Description PK Cat. No.

Cyclone-suction-combination incl. vacuum cleaner 230V/50Hz, 500ml sample bottleHolder for use of sample bottles 1L / 2L / 5LSample bottle 1LSample bottle 2LSample bottle 5L

11111

9.739 6029.739 6039.739 6049.739 6059.739 606

Bottom sieves for cutting mill SM 100/200/3003Retsch

Description Aperture size

PK Cat. No.

mmConidur holesConidur holesConidur holesConidur holesConidur holesConidur holesSquare holesSquare holesSquare holesSquare holesSquare holes

0.250.500.751.001.502.004.006.008.0010.0020.00

11111111111

9.738 8549.738 8559.738 8569.738 8579.738 8589.738 8599.738 8159.738 8169.738 8179.738 8189.739 055

3

Page 16: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

491

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Knife Mills GRINDOMIX GM 200/GM 300 NEW!NEW!

The Knife Mills Grindomix GM 200 and GM 300 are suitable for the rapid andreproducible size reduction and homogenisation of food and feed materials. They canprocess substances with a high water, oil or fat content just as quickly and reliably as dry, soft and medium-hardproducts.

Features:- Very fast and reproducible grinding and homogenisation of foodstuffs- Speed-controlled industrial motor- Autoclaveable grinding tools- For sample volumes up to 4.5L (GM 300)- Digital display of grinding time and speed- Interval operation possible- Gravity lid for automatic adjustment of grinding chamber volume- 10 parameter combinations can be stored (GM 300)- Electrical supply data: different voltages, Power connection: 1-phase

Supplied with:GM 200 complete with 1L plastic container, lid and stainless steel knife.GM 300 complete with 5L plastic container, standard lid, standard knife and scraper.

1Retsch

Type Feed size

up to

MaximumThroughput/Charge

Dimensions(W x D x H)

Weight PK Cat. No.

mm mm kgGM 200GM 300

40~ 130

700 ml4500 ml

350 x 392 x 275440 x 440 x 340

10.030.0

11

9.739 2529.738 500

1

Accessories for Knife Mill GM 200 NEW!NEW!

Retsch

Description PK Cat. No.

Grinding container 1 litre plastic, autoclavableGrinding container of PP, 1LGrinding container of glass, 1LGrinding container of stainless steel, 1LStandard lid of PP for grinding container of autoclavable plastic, PP, glass or steelPP standard lid 1L for glass, steel and plastic containersReduction lid of PP for volume reduction to 0.5L for grinding container of autoclavable plastic or PPGravity lid PP for grinding container of autoclavable plastic and PPGravity lid of PP with overflow channels for grinding container of autoclavable plastic and PPGravity lid of PP for grinding container of glass or steelGravity lid of PP with overflow channels for grinding container of glass or steelScraperKnife of stainless steelKnife of pure titanium for heavy-metal free grinding

11111111111111

9.738 5109.739 2139.739 2089.739 2487.930 4309.739 2149.739 2229.739 2109.739 2189.739 2119.739 2099.739 2129.739 2159.739 059

Accessories for Knife Mill GM 300 NEW!NEW!

Retsch

Description PK Cat. No.

Cutting container of plastic, transparent, autoclavable and scratch-resistant, 5L, including knife holderCutting container of plastic, transparent, autoclavable and scratch-resistant, 5L, without knife holderCutting container of stainless steel, autoclavable, 5L, including knife holderCutting container of stainless steel, autoclavable, 5L, without knife holderStandard lid of plastic, transparent, autoclavable and scratch-resistantGravity lid of plastic, autoclavable and scratch-resistantGravity lid of plastic, with overflow channels, autoclavable and scratch-resistantStandard knife made of stainless steel, autoclavableScraper

111111111

9.738 5019.738 5029.738 5039.738 5049.738 5059.738 5069.738 5079.738 5089.738 509

Page 17: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

492

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Disc Mill DM 200The DM 200 disc mills are mainly used for preliminary and fine grinding of medium-hardand hard-brittle substances in batches.Grinding discs are available in 4 different materials.

Specifications:- feed size: up to 20mm- ultimate fineness: up to 0.1mm- throughput: up to 150 kg/hr.- dimensions (WxDxH): 440 x 400 x 870mm- weight: approx. 140kg- supply requirement: 400V, 50/60Hz 3ph.

Supplied with: disc mill DM 200 without grinding assembly.Please order grinding assembly separately.

1Retsch

Type PK Cat. No.

DM 200 1 9.739 030

1

Accessories for Disc Mill DM 200Retsch

Type PK Cat. No.

Grinding assembly - hardened steelGrinding assembly - manganese steelGrinding assembly - tungsten carbideGrinding assembly - zirconium oxide

1111

9.739 0319.739 0329.739 0339.739 034

Mortar Grinder RM 200Suitable for dry and wet grinding of soft, brittle, hard and paste-like samples. Dependingon the sample, amounts from approx. 10ml up to 190ml can be reduced in size,triturated andhomogenised. With beech wood scraper (special accessory) for pharmaceutical and homeopathic applications. The RM200 is exceptionally easy to operate and clean. With digital time control and performance display, scale for reproduciblepestle setting, built-in automatic switch-off and rapid motor-stop.Please order mortar and pestle separately.

2Retsch

SpecificationsFeed size*: max. 8mmBatch size/Feed volume: 10 to 190mlUltimate fineness*: approx. 10µmDimensions (WxDxH): 400 x 370 x 480mmWeight: approx: approx. 24 kg (without grinding set)Supply requirements: 220 - 240V 50Hz*depending on feed material

Type PK Cat. No.

RM 200 1 9.738 170

2

Accessories for Mortar Grinder RM 200Retsch

Description PK Cat. No.

Mortar, hard porcelainMortar, agatePestle, hard porcelainPestle, agate

1111

9.738 1519.738 1729.738 1739.738 174

Mortars and pestles made from zirconium oxide, sintered corundum, steel and tungsten carbide are available on request.

Page 18: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

493

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Mixer Mills MM 200/400The mixer mills are true laboratory "all-rounders". They have been developed specially forgrinding, homogenising and mixing of small amounts of sample in only a few seconds.They are also perfectly suitable for the disruption of biological cells as well as for DNA/RNA recovery. The MM 400 canalso be used for cryogenic and wet grinding.

Features:- 2 milling stations- Digital setting of time and vibration intensity- 9 separate programmes can be stored- Wide selection of grinding jar sizes and materials- Self-locking and self-centering, clamping device for grinding jars (MM 400)- Screw-top grinding jars up to 50ml, especially suitable for wet and cryogenic grinding (MM 400)

Accessories for cryogenic grinding available on request.Grinding jars and balls please order separately.

1Retsch

SpecificationsFeed size*MM 200: up to 6mmMM 400: up to 8mmUltimate fineness*MM 200: < 10µmMM 400: < 5µmChargeMM 200: max. 2 x 10mlMM 400: max. 2 x 20mlDigital preselection of vibrational frequencyMM 200: 3 to 25Hz (180 to 1500rpm.)MM 400: 3 to 30Hz (180 to 1500rpm.)Power supply: 100 - 240V 50/60Hz*depending on feed material

Type Dimensions(W x D x H)

Weight PK Cat. No.

mm kgMM 200MM 400

371 x 461 x 266371 x 461 x 266

25.0026.00

11

9.739 0809.739 091

1

Mixer Mill CryoMillThe CryoMill is designed for the cryogenic size reduction of materials which cannot beground at room temperature or whose composition would be changed by it. The grindingjar is cooled before and during the grinding process with liquid nitrogen through an integrated cooling system. Thus thesample is embrittled and its volatile components are preserved. The size reduction principle is the same as that of thewell-proven Mixer Mill MM 400. The CryoMill can also be operated without the cooling system which makes it suitable fora wide range of applications.

Features:- fast, efficient cryogenic grinding and homogenization at -196°C- perfect for preparation of temperature-sensitive samples and plastics- safe and convenient thanks to an integrated cooling system with Autofill- programmable cooling cycles, digital parameter setting- easy to operate and clean- 1 grinding station

2Retsch

SpecificationsFeed size up to 8mmUltimate fineness < 5µmCharge max. 1 x 20mlAdjustable frequency range 3 to 25Hz (180 to 1500rpm.)Size (W x H x D) 385 x 370 x 570mmWeight 46kgPower supply: 100 - 240V, 50/60Hz

Type PK Cat. No.

CryoMill 1 9.739 280Please order Autofill, grinding jars and grinding balls separately.

2

Page 19: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

494

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Grinding Jars for Mixer Mill MM 2001Retsch

Material Capacity PK Cat. No.ml

Stainless steel 1.5mlStainless steel 5mlStainless steel 10mlStainless steel 25mlAgate 5mlAgate 10ml

1.55.0

10.025.05.0

10.0

111111

9.738 8239.738 8299.738 8359.738 8399.738 8279.738 833

Grinding jars made of hardened steel, tungsten carbide, zirconium oxide and PE-HD are available on request.

1

Grinding Jars for Mixer Mill MM 400With screw cap.

Advantages:- simple and safe handling- dust and air-tight- Suitable for wet and cryogenic grinding

2Retsch

Material Capacity PK Cat. No.ml

Stainless steelStainless steelStainless steelStainless steelStainless steelStainless steelAgateAgateZirconium oxideZirconium oxideZirconium oxideTungsten carbideTungsten carbidehardened steelPTFE

1.55.0

10.025.035.050.05.0

10.010.025.035.010.025.025.025.0

111111111111111

9.738 8489.738 8499.738 9609.738 9649.738 8759.738 8859.738 8529.738 9619.738 9629.738 9659.738 8809.738 9639.738 8649.738 8699.738 874

2

Grinding Jars for CryoMill NEW!NEW!

Retsch

Material Capacity PK Cat. No.ml

Stainless steel (to be used with adapter)Stainless steelStainless steelStainless steelHardened steel (to be used with adapter)Hardened steelHardened steelHardened steelPTFE

52535505

25355025

111111111

9.739 2819.739 2829.739 2839.739 2849.739 2879.739 2889.739 2899.739 2909.739 291

Accessories for Mixer Mill, CryoMill NEW!NEW!3

Retsch

Type PK Cat. No.

Autofill with LN2 container, 10LAutofill with LN2 container, 50LAdapter for use of 2/4 grinding jars, 5ml stainless steelAdapter for use of 2/4 reaction tubes, 2.0mlReaction tubes, 2.0ml

111

1

1000

9.739 2859.739 2929.739 286

9.739 297

9.739 298

3

Page 20: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

495

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Ball charge table for grinding jars MM 200/MM 400/CryoMill

Grinding jars Capacity Feed size

up to

Balldia.

Bulbs

ml ml mm mm1.55.010.025.035.050.0

0.2 - 0.50.5 - 2.02 - 44 - 106 - 158 - 20

124668

57

10 / 1210 / 12 / 15

10 / 12 / 15 / 2010 / 12 / 15 / 20 / 25

1 - 21 - 2

1-2 / 1-25-6 / 2-4 / 1-2

6-9 / 4-6 / 2-3 / 112-14 / 6-8 / 3-4 / 1 / 1

Grinding balls for Mixer Mill MM 200/MM 400/CryoMillRetsch

Material Dia. PK Cat. No.mm

Zirconium oxideZirconium oxideZirconium oxideZirconium oxideHardened steelStainless steelStainless steelStainless steelStainless steelStainless steelStainless steelStainless steelTungsten carbideTungsten carbideTungsten carbidePTFE with steel corePTFE with steel coreAgateAgateAgateAgate

121520251557

10121520251012151520579

12

111111111111111111111

9.738 8469.738 4059.738 8479.738 4019.738 4079.738 8709.738 8719.738 8729.738 8739.738 4089.738 3879.738 4039.738 8789.738 8799.738 4149.738 4209.738 8889.738 8609.738 8619.738 8629.738 863

Planetary Ball Mills PM 100/100 CM/200/400Planetary Ball Mills are suitable for mixing and grinding soft, medium-hard, extremelyhard, brittle and fibrous materials. They are used whenever high degrees of fineness down tothe submicron range are to be achieved in a very short time. In addition to dry and wet grinding, they are also suitablefor colloidal grinding and mechanical alloying. Typical materials are minerals, ores, chemicals, ceramics, soils, householdand industrial waste etc.

Features:- extremely high ultimate fineness down to submicron range- 1, 2 or 4 grinding stations- grinding jar volumes from 12ml to 500ml- suitable for long-term trials and continuous use- programmable starting time- power failure back-up ensures storage of remaining grinding time- reproducible results due to digital parameter setting- 10 parameter combinations can be stored- single button operation with graphic display- automatic grinding chamber ventilation for cooling the grinding jars- grinding jars in 7 sizes and 6 different materials available

Supplied with: Planetary Ball Mill only. Grinding jars and grinding balls have to be ordered separately.The PM100 CM is a Planetary Ball Mill with a speed ratio of 1:-1. Size reduction is not so much achieved by impact butby pressure and friction which is more gentle on the material.

1Retsch

SpecificationsUltimate fineness: < 1µmDimensions (WxDxH): 630 x 468 x 415mmPM 400 836 x 780 x 1220mmSupply requirements: 230V, 50-60Hz

1

Type Grindingstations

Grinding jars Feed size

up to

MaximumThroughput/Charge

Weight PK Cat. No.

ml mm kgPM 100PM 100 CMPM 200PM 400

1124

12 to 50012 to 50012 to 125

12 to 500 ml

up to 10up to 10up to 4

up to 10

up to 220 mlup to 220 mlup to 2 x 50 mlup to 8 x 20 ml

80.0080.0072.00

285.00

1111

9.739 2709.739 2759.739 2719.739 274

Please order grinding jars and grinding balls separately.

Page 21: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

496

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Grinding Jars for Planetary Ball Mills PM 100/100 CM/200/4001Retsch

Material Capacity PK Cat. No.ml

Hardened steelHardened steelHardened steell*Hardened steel*Stainless steelStainless steelStainless steel*Stainless steel*Tungsten carbideTungsten carbideTungsten carbide*AgateAgateAgate*Agate*Sintered aluminium oxideSintered aluminium oxideSintered aluminium oxide*Sintered aluminium oxide*Zirconium oxideZirconium oxideZirconium oxide*Zirconium oxide*

5012525050050

12525050050

12525050

12525050050

12525050050

125250500

11111111111111111111111

9.738 3209.738 3399.738 2169.738 2229.738 3219.738 3409.738 2179.738 2239.738 3119.738 3389.738 2189.738 3289.738 3459.738 2199.738 2249.738 3279.738 3449.738 2209.738 2269.738 3259.738 3429.738 2219.738 227

*not suitable for PM 200.Further grinding jars on request

1

Ball charge table for grinding jars PM 100/100 CM/200/400

Grinding jars Capacity Feed size

up to

Balldia.

Bulbs

ml ml mm mm50.080.0125.0250.0500.0

5 - 2010 - 3515 - 5025 - 12075 - 220

346

1010

5 / 10 / 15 / 205 / 10 / 15 / 205 / 10 / 15 / 20

5 / 10 / 15 / 20 / 305 / 10 / 15 / 20 / 30 /40

200 / 10 / 7 / 3250 / 25 / 10 / 5500 / 30 / 18 / 7

1200 / 50 / 45 / 15 / 62000 / 100 / 70 / 25 / 8 / 4

Grinding Balls for PM 100/100 CM/200/4002Retsch

Material Dia. PK Cat. No.mm

AgateAgateAgateAgateSintered aluminium oxideSintered aluminium oxideSintered aluminium oxideSintered aluminium oxideHardened steelHardened steelHardened steelHardened steelStainless steelStainless steelStainless steelStainless steelStainless steel 0.5 kgStainless steel 0.5 kgZirconium oxideZirconium oxideZirconium oxideZirconium oxideZirconium oxide, 0.5 kgZirconium oxide, 0.5 kgTungsten carbideTungsten carbideTungsten carbideTungsten carbide

1020304010203040102030401020304023

1020304023

10203040

1111111111111111111111111111

9.738 3839.738 3889.738 3939.738 3989.738 3809.738 3859.738 3909.738 3959.738 3819.738 3869.738 3919.738 3969.738 3829.738 3879.738 3929.738 3979.738 4259.738 4269.738 4199.738 8479.738 4179.738 4189.738 4279.738 4289.738 3849.738 3899.738 3949.738 399

2

Page 22: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

497

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Jaw crushers PULVERISETTE 1 (2 Models)Ideal for fast and effective pre-crushing of hard and very hard brittle materials in theareas of mining and metallurgy, chemistry, geology and mineralogy, glass industry,ceramics industry, rocks and soils. The final fineness can be easily set from the outside (10 different stages arepossible).

Equipment Model I/II:With crushing jaws and lateral support walls made of tempered steel.Crushers are also available in other voltages and with crushing jaws and lateral support walls made of stainless steel,chromium-free steel, hardmetal tungsten carbide, zirconium oxide and manganese steel.

1Fritsch

Model I/Model IIMax. feed size: approx. 60mm/approx. 95mmThroughput: up to 140kg/h/up to 200kg/hGap widths (final fineness): 1 to 15mm/1 to 15mmSupply requirements: 400V/3~, 50-60Hz/400V/3~, 50-60HzDimensions (WxDxH): 400 x 800 x 800mm/400 x 800 x 800mmNet weight: 177kg/205kg

Type Rating PK Cat. No.W

Jaw Crusher PULVERISETTE 1 model IJaw Crusher PULVERISETTE 1 model II

14502780

11

9.519 2139.519 223

1

Disk mill PULVERISETTE 13Ideal for intermittent and continuous fine grinding of hard-brittle and medium-hard solids inthe areas of mining and metallurgy, glass industry, ceramics industry, soil research, rocks andsoils.

2Fritsch

Max. feed size: 20mmThroughput: up to 150kg/hFinal fineness: 0.1 to 12mmSupply requirements: 400V/3~, 50-60Hz, 1830WDimensions (WxDxH): 440 x 870 x 40mmNet weight: 140kg

Type PK Cat. No.

Disk mill PULVERISETTE 13 1 9.739 001Instrument also available in other voltages.Fixed and movable grinding disks must be ordered additionally.

2

Accessories for disk mill PULVERISETTE 13Fritsch

Type Description PK Cat. No.

Fixed grinding diskMobile grinding diskFixed grinding diskMobile grinding disk

hardened steel casthardened steel castzirconium oxidezirconium oxide

1111

9.739 0029.739 0039.739 0069.739 007

Grinding disks are also in manganese steel and hardmetal tungsten carbide available.

We can supply this

manufactorer’swhole

product range !

Page 23: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

498

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Mortar grinder PULVERISETTE 2Ideal for universal fine grinding of hard-brittle to soft samples, dry or in suspension, as well as for preparing and homogenising pastes and creams on a laboratory scale. ThePULVERISETTE 2 is an essential instrument in the chemical/pharmaceutical as well as in food processing laboratories.The Mortar grinder is easy to clean ensures reproducible and precise grinding results, due to precise adjustment andpestle pressure readout. Also working with liquid nitrogen for cooling/embrittlement is no problem.

1Fritsch

Max. feed size: 8mmMax. sample quantity: 30 to 150mlFinal fineness: 10 to 20µmSupply requirements: 100-120/200-240V/1~, 50-60Hz, 250WDimensions (WxDxH): 310 x 460 x 410mmNet weight: 24kg

Type PK Cat. No.

Mortar Grinder PULVERISETTE 2 1 9.738 200Mortar and pestle must be ordered additionally.

1

Accessories for mortar grinder PULVERISETTE 2Fritsch

Material PK Cat. No.

AgateStainless steelHard porcelain

111

9.738 2119.738 2359.738 240

Mortars and pestles are also available in sintered corundum, hardmetal tungsten carbide and zirconium oxide.

Planetary ball mills PULVERISETTE 5/6 classic lineIdeal for fast, loss-free fine grinding of hard, medium-hard, brittle and fibrous materials,dry or in suspension. Sample can be processed from a few milligrams to several kilograms ata wide range of fineness levels down to less than 1µm. They are especially easy to operate and fast and easy to clean.They are suitable for continuous, heavy duty usage and guarantee safe clamping of the grinding bowls. Matchinggrinding parts of 8 different materials are available to provide maximum protection against undesired contamination. Inaddition to size-reduction, Planetary Ball Mills can also be used for mixing and homogenising of emulsions and pastes orfor mechanical alloying and activation. Example areas: geology and mineralogy, sample preparation for analysis,ceramics, chemistry, biology, pharmaceuticals, metallurgy and much more.

Features:- Extremely high rotational speeds of the main disk for particularly high final finenesses- Very fast, uniform and reproducible size reduction- Loss-free grinding also in suspensions, due to a seal ring in the grinding bowl- Reproducible grinding results due to controlled drive and programmable electronic system- Programmable interval-, break-times and reversing unit- RS232 interface for data transfer of process parameters (validation)- Microprocessor control electronic system and precise digital display of all functions (also of rotational speed)

FRITSCH also offers a revolutionary Planetary Mill Generation premium line generation, worldwide unique in operation,performance and safety, a new reference class, please have a look at Planetary Micro Mill PULVERISETTE 7 premiumline.

2Fritsch

Max. feed size: 10mmFinal fineness: < 1µmGrinding bowl sizes: 80, 250, 500mlSupply requirements: 100-120/200-240V/1~, 50-60HzDimensions (WxDxH): 370 x 530 x 500mm PULVERISETTE 6 classic line

580 x 670 x 570mm PULVERISETTE 5 classic line

2

Type Grindingstations

Rotationspeed

Samplevolume

Weight PK Cat. No.

rpm ml kgPlanetary Mono Mill PULVERISETTE 6 classic linePlanetary Mill PULVERISETTE 5 classic line model IPlanetary Mill PULVERISETTE 5 classic line model II

1

4

2

100-650

50-400

50-400

225

900

450

63

120

100

1

1

1

9.738 300

9.738 404

9.738 402

Grinding bowls and grinding balls must be ordered additionally.

Page 24: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

499

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Grinding bowls for planetary ball mills PULVERISETTE 5/6 classic line NEW!NEW!1

Fritsch

Material Capacity PK Cat. No.ml

Tempered steelTempered steelTempered steelStainless steelStainless steelStainless steelSintered corundumSintered corundumSintered corundumZirconium oxideZirconium oxideZirconium oxideHardmetal tungsten carbide**Hardmetal tungsten carbide**Adapter for grinding bowls

8025050080*25050080*25050080*25050080*25080

111111111111111

9.738 5159.738 5259.738 5359.738 5169.738 5269.738 5369.738 5129.738 5229.738 5329.738 5189.738 5289.738 5389.738 5149.738 5249.738 315

* One grinding bowl holder can hold either 2 x 80ml bowls or 1 x 80ml bowl together with a grinding bowl adapter mounted one on top of the other.** Grinding bowl in a steel casing.Grinding bowls are also available in agate and silicon nitride. Special gassing lids for grinding in an inert atmosphere and for mechanical alloying as well as theGTM-system (Gas pressure and temperature measuring system), for measuring gas pressure and temperature during the grinding process are available.

1

Grinding balls for grinding balls PULVERISETTE 5/6 classic line NEW!NEW!2Fritsch

Material Balldia.

PK Cat. No.

mmTempered steelTempered steelTempered steelTempered steelStainless steelStainless steelStainless steelStainless steelSintered corundumSintered corundumSintered corundumSintered corundumZirconium oxideZirconium oxideZirconium oxideZirconium oxideHardmetal tungsten carbideHardmetal tungsten carbideHardmetal tungsten carbideHardmetal tungsten carbide

1020304010203040102030401020304010203040

11111111111111111111

9.738 5559.738 5659.738 5759.738 5859.738 5569.738 5669.738 5769.738 5869.738 5529.738 5629.738 5729.738 5829.738 5589.738 5689.738 5789.738 5889.738 5549.738 5649.738 5749.738 584

Grinding bowls are also available in agate and silicon nitride.Grinding balls are also offered in the diameters 0.1mm to 3mm (to achieve a fineness down to the nanometer-range) as well as in 5mm and 15mm (have alook at grinding balls for grinding bowls for planetary micro mill PULVERISETTE 7 premium line).

2

Recommended number of grinding balls per grinding bowl for PULVERISETTE 5/6classic line

Grinding bowlUseful capacity (sample volume)Ball diameter5mm10mm15mm20mm30mm40mm

500ml80 - 225ml

2000100702584

250ml10 - 125ml

12005045156

80ml10 - 30ml

25025105

Page 25: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

500

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Planetary micro mill PULVERISETTE 7 premium line NEW!NEW!

As extension of the existing classic line planetary mills, FRITSCH offers now a newpremium line generation. For the first time ever, it is possible to reach rotational speedsnever known before, which achieves ultrafine grinding results down to the nano range.

FASTER, SIMPLER AND SAFER THAN EVER.

Features:- Extremely high-speed milling thanks to sunken grinding bowls with up to 1100rpm- Sensational centrifugal accelerations of up to 95 times the force of gravity for better results in shorter times- 150% greater energy application than conventional Planetary Ball Mills- Extremely easy grinding bowl change with just two motions- Highest safety due to unique SelfLock-grinding bowl-clamping- For the first time, the bowl and lid form a single unit, no additional tensioning, no incorrect operation- Automatic check of the grinding bowl locks in the mill- Blockage in the event of impermissible operating state- Automatic parameter check performed before every grinding, guarantees exact reproducibility- Via USB all data can be easily exported to save time

1Fritsch

Max. feed size: 5mmMax. sample quantity: 70mlFinal fineness: < 100nmRotational speed of main disk: 100 to 1100rpmSupply requirements: 100-240V/1~, 50-60Hz, 1100WDimensions (WxDxH): 400 x 580 x 360mmNet weight: 44kg

Type PK Cat. No.

Planetary Micro Mill PULVERISETTE 7 premium line 1 6.233 706Grinding bowls and grinding balls must be ordered additionally.

1

Grinding bowls for planetary micro mill PULVERISETTE 7 premium line NEW!NEW!2

Fritsch

Description Capacity PK Cat. No.ml

Stainless steel*Stainless steel*Stainless steel*Sintered corundum*Sintered corundum*Sintered corundum*Zirconium oxide*Zirconium oxide*Zirconium oxide*Hardmetal tungsten carbide*Hardmetal tungsten carbide*Hardmetal tungsten carbide*

204580204580204580204580

111111111111

9.738 4559.738 4549.738 4539.738 4599.738 4609.738 4619.738 4589.738 4579.738 4566.237 2869.738 2319.738 232

* Grinding bowl in a steel casing.Special gassing lids for grinding in an inert atmosphere and for mechanical alloying as well as the EASY GTM - Gas pressure and temperature measuringsystem, for measuring gas pressure and temperature during the grinding process and for controlling the grinding process are available.

2

Grinding balls for grinding bowls PULVERISETTE 7 premium line NEW!NEW!3Fritsch

Material Balldia.

PK Cat. No.

mmStainless steelStainless steelZirconium oxideSintered corundumZirconium oxideHardmetal tungsten carbideHardmetal tungsten carbide

5155

15155

15

1111111

9.738 5609.739 1659.739 1609.739 1629.739 1666.050 3299.739 163

Grinding bowls are also available in agate, tempered steel and silicon nitride.Grinding balls are also offered in the diameters 0.1mm to 3mm (to achieve a fineness down to the nanometer-range) as well as in 10mm and 20mm (have alook at grinding balls for grinding bowls for planetary mono mill PULVERISETTE 6 classic line and planetary mill PULVERISETTE 5 classic line).

3

Page 26: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

501

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Recommended number of grinding balls per grinding bowl for PULVERISETTE 7premium lineGrinding bowlUseful capacity (sample volume)Ball diameter5mm10mm15mm20mm

20ml1 - 9ml

8010--

45ml3 - 20ml

180187-

80ml10 - 30ml

25025105

Mini mill PULVERISETTE 23Ideal for fine comminution of smallest quantities for wet and dry grinding as well as forcryogenic grinding. Its special spherical grinding bowl ensures much better performancein grinding, mixing and homogenising compared with similar models for example in chemical analysis, chromatography,mass spectrometry or x-ray structural analysis, preparation of samples for genetic research, homogenising of activeingredients, preparation of extracts in the forensic analysis, grinding of pigments and precious materials.

1Fritsch

Max. feed size: 6mmMax. sample quantity: up to 5mlFinal fineness: 5µmSupply requirements: 100-240V/1~, 50-60HzDimensions (WxDxH): 200 x 300 x 300mmNet weight 7kg

Type PK Cat. No.

Mini Mill PULVERISETTE 23 1 9.739 345Grinding bowls and grinding balls must be ordered additionally.

1

Recommended number of grinding balls per grinding bowl for mini mill PULVERISETTE 23Grinding bowlUseful capacity (sample volume)Ball diameter5mm10mm15mm

5ml0.01 - 1ml

201-

10ml0.2 - 1ml

3031

15ml0.5 - 5ml

6052

Grinding bowls and grinding balls for mini mill PULVERISETTE 232

Fritsch

Type PK Cat. No.

Grinding bowl, PTFE, 5mlGrinding bowl, stainless steel, 10mlGrinding bowl, stainless steel, 15mlGrinding ball, 5mm, stainless steelGrinding ball, 10mm, stainless steelGrinding ball, 15mm, stainless steel

111111

9.739 3439.739 3469.739 3479.738 5609.738 5569.739 165

Grinding bowls and balls are also offered in zirconium oxide and tempered steel, as well as grinding balls in 15mm diameter (have a look at grinding balls forgrinding bowls: planetary micro mill PULVERISETTE 7 premium line).

2

Page 27: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

502

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Variable speed rotor mill PULVERISETTE 14Ideal for fast, effective comminution of soft to medium-hard, brittle, fibrous materials, aswell as difficult-to-mill and temperature-sensitive samples. Cryogenic grinding, dispersionand homogenisation is also one of the areas of operation. The variable speed rotor mill is an ultra-centrifugal mill withvariable speed settings between 6.000rpm and 20.000rpm and automatic speed regulation for constant milling in theareas of analytic, biology, chemistry, agriculture and forestry, foodstuffs, plastics and textiles, pharmaceuticals,environment/RoHS. For optimal material feeding the Vibratory Feeder LABORETTE 24 (optional) is recommended.

1Fritsch

Max. feed size: 10mmThroughput: 0.05 to 5L/hSieve inserts: 0.08 to 6mmFinal fineness (d50): 40µmRotor speed: 6.000 to 20.000rpmSupply requirements: 100-120/200-240V/1~, 50-60Hz, 1150WDimensions (WxDxH): 310 x 480 x 470mmNet weight: 23kg

Type PK Cat. No.

Variable speed rotor mill PULVERISETTE 14 1 9.738 281Impact rotor and sieve ring must be ordered additionally.

1

Accessories for variable speed rotor mill PULVERISETTE 14 made of stainless steel2

Fritsch

Type PK Cat. No.

Impact rotor with 8 finsImpact rotor with 12 finsImpact rotor with 24 finsSieve rings, trapezoidal holes 0.08mmSieve rings, trapezoidal holes 0.12mmSieve rings, trapezoidal holes 0.2mmSieve rings, trapezoidal holes 0.5mmSieve rings, trapezoidal holes 0.75mmSieve rings, trapezoidal holes 1mmSieve rings, trapezoidal holes 1.5mmSieve rings, trapezoidal holes 2mmSieve rings, round holes 1mmSieve rings, round holes 2mmSieve rings, round holes 4mmSieve rings, round holes 6mmConversion kit for large quantitiesVibratory feeder LABORETTE 24 for continuous feedingStand for vibratory feeder LABORETTE 24

111111111111111111

9.738 2829.738 2839.738 2849.738 2869.738 2879.738 2889.738 2899.738 2859.738 2909.738 2789.738 2799.738 2919.738 2929.738 2939.738 2949.738 3299.738 2999.738 298

Rotors and sieve rings are also available in others designs and materials. An extensive accessory programme with impact bar, pin insert, sample exhauster withcyclone separator and much more is available for your specific application.

2

Page 28: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

503

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Cutting mill PULVERISETTE 15 and universal cutting mill PULVERISETTE 19

Ideal for pre and fine grinding of soft to medium-hard as well as fibrous or tough materials.They are essential for the areas of plastics, textiles, agriculture and forestry, environmental,construction materials, chemistry, foodstuffs and for sample preparation for RoHS analysis. All grinding parts can beremoved for cleaning in just a few seconds without tools, unbeatable fast, simple and efficient. Different rotors, variousknife geometries and replaceable blades ensure maximum flexibility and durability. For controlling the abrasionproperties, the grinding tools are offered in different materials. The optimum airflow ensures fast grinding and secureprotection against clogging. The patented FRITSCH sample exhauster with cyclone separator (optional) ensures simplefeeding, fast throughput and good cooling.

Fritsch

Max. feed size: up to 70 x 80mm*Throughput: up to 60L/hSieve inserts: 0.25 to 6mmSupply requirements: 400V/3~, 50-60HzDimensions (WxDxH): 420 x 480 x 690mm resp. 440 x 550 x 630mm** depending on the instrument type

1

9.738 421

2

9.739 300

12

Type Feed size

up to

Throughputmax.

Rotationspeed

Weight PK Cat. No.

mm l/h rpm kgCutting mill PULVERISETTE 15Universal cutting mill PULVERISETTE 19

70 x 7070 x 80

5060

28002800

4256

11

9.738 4219.739 300

Instruments also available in other voltages.Funnels, rotors, sieve inserts/sieve cassettes and collecting vessels must be ordered separately.

Accessories for cutting mill PULVERISETTE 15 NEW!NEW!3Fritsch

Type PK Cat. No.

Funnel for long and bulk solidsCutting rotor made of tool steelSieve insert, trapezoidal holes 0.25mmSieve insert, trapezoidal holes 0.5mmSieve insert, trapezoidal holes 1mmSieve insert, trapezoidal holes 2mmSieve insert, square holes 4mmSieve insert, square holes 6mmCollecting vessel, 3.5LCollecting vessel, 60L with filter hoseStand

11111111111

7.900 1409.738 4249.738 4329.738 4339.738 4359.738 4379.738 4419.738 4426.231 2699.738 4499.738 429

Alternative funnels as well as sieve inserts made of stainless steel are also available in other perforations. Cutting rotors as well as the sieve insert are alsooffered in chromium-free steel.

3

Accessories for universal cutting mill PULVERISETTE 194Fritsch

Type PK Cat. No.

Standard funnel for long and bulk solidsStandard rotor with V-cutting,edges and fixed knives made of tool steelSieve cassette , trapezoidal perforation 0.5mmSieve cassette , trapezoidal perforation 1mmSieve cassette , trapezoidal perforation 2mmCollecting vessel, 3LLarge collecting vessel, 10LStand

11

111111

6.510 3199.739 321

9.739 3319.739 3339.739 3359.739 3509.739 3519.738 429

Alternative funnels, cutting rotors in other materials and designs, sieve cassettes in alternative meshes and sample exhauster with cyclone separator areavailable on request.

4

Page 29: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

504

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Micro fine mills, CulattiFor the continuous grinding of dry and brittle substances. For example: plastic, minerals, slag, coke, coal, spices, glass,cement clinker, oilseed rape, etc. The mill operates continuously without loss of material, and operates on the hammermill principle. With automatic quick-stop. Maximum permissible operating time: 15mins. Supplied with1.0mm/1.5mm/2.0mm mesh sieves, rack with 12 receiver tubes and cleaning instruments.

1

Speed: 0 to 5000 rpm.Dimensions (WxDxH): 150 x 250 x 260 mmWeight: 6.5 kgSupply requirements: 230 V 50/60 Hz.

Type PK Cat. No.

Culatti 1 9.737 840

1

Analytical mill A 10 basic NEW!NEW!

Suitable for low-loss dry grinding of soft, hard and brittle substances- With a built-in cooling chamber- Removable, easy-to-clean, high-grade steel chamber- 3 interchangeable cutters available- Electronic overload protection

2IKA

SpecificationsMotor rating input/output: 180/80WSpeed: 20000rpmChamber vol.: 50mlPower-on time ON/OFF: 5/10minAuto power off: yesTangential speed: 57m/sec.Max. sample granule size: 6mmDimensions (WxDxH): 120 x 105 x 225mmWeight: 2.2kgProtection class DIN EN 60529: IP 21Supply requirements: 230V 50/60HzTested to DIN EN IEC 61010-1.

Type PK Cat. No.

A 10 basic 1 9.737 800

2

Accessories for Grinding mill, A10 basic NEW!NEW!

A 14 Beater, stainless steelFor most brittle materials with a Mohs hardness up to 5.A 15 Beater, hard metalMade from tungsten carbide for hard materials with a Mohs hardness up to 9.A 17 Cutter, stainless steelFor specific lightweight materials like paper, dried plant parts, plastics and for smooth-elastic materials.A 18 Grinding chamber reductionFor small grinding volumes.

3IKA

Type Description PK Cat. No.

A14A15A17A 18

Beater, stainless steel*Beater, hard metalCutter, stainless steelGrinding chamber reduction*

1111

9.737 8119.737 8129.737 8147.017 783

*included in delivery

3

Page 30: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

505

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Grinding mill, A11 basicNewly designed batch analysis mill with two grinding functions: grinding hard, brittlematerials using a beater, or slicing soft, fibrous materials using a rotating cutter.- speed without load: 28000rpm.- supplied with 80ml standard grinding container and stainless steel beater.

1IKA

SpecificationsMotor rating input/output: 160/100WSpeed: 28000rpm (off load)Chamber vol.: 80mlPower-on time ON/OFF: 1/10 minAuto power off: yesTangential speed: 53m/sec.Max. sample granule size: 10mmDimensions (WxDxH): 85 x 85 x 240mmWeight: 1.5kgProtection class DIN EN 60529: IP 43Supply requirements: 230V 50/60HzTested to DIN EN IEC 61010-1.

Type PK Cat. No.

A 11 basicA 11 basic UK

11

9.737 8016.202 305

Optional accessories: A 11.4 Grinding chamber (250ml), A 11.1 Spare beater, A 11.2 Cutting blade, A 11.6 Double beater, A 11.5 Spare grinding chamber , A11.7 Funnel, A 11.3 Beater

1

Accessories for Grinding mill, A11 basicA 11.1 Spare beaterFor pulverising substances with a Mohs hardness up to 6.A 11.2 CutterFor pulverising soft, fibrous grinding materials.A 11.3 Beater, hard metalFor pulverising substances with a Mohs hardness up to 9, chrome-carbide coatedA 11.4 Grinding container, 250mlMade of polycarbonate with stainless steel inlet. Not suitable for cooling with N2, only applicable with double beater A11.6.A 11.5 Spare grinding container, 80mlMade of Tefcel (PTFE, glass faser-reinforced) with stainless steel inlet. Excellent resistance to chemicals and lowtemperatures (- 200°C).A 11.6 Dubbel beaterFor use up to Mohs hardness 3. Only applicable with grinding chamber A 11.4.A 11.7 FunnelPrevents splashing by pouring in liquid nitrogen in the grinding chamber A 11.5.

2IKA

Type Description PK Cat. No.

A 11.1A 11.2A 11.3A 11.4A 11.5A 11.6A 11.7

Spare beater*CutterBeaterGrinding container, 250mlSpare grinding container, 80 ml*Double beaterFunnel

1111111

9.737 8159.737 8069.737 8079.737 8059.737 8169.737 8179.737 818

*included in delivery

2

Page 31: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

506

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Universal mill M20Batch mill suitable for dry grinding of hard and brittle substances.- Double-walled grinding chamber can be cooled with water through two hose adapters- Removable grinding chamber, easy to clean- Two grinding chambers can be alternately operated using one drive- M 21 blade incl. with delivery

1IKA

Specifications:Motor rating input/output: 440/225WSpeed: max. 20000rpm. off loadOverload protection: current limiterThroughput/Charge max: 250mlMaterial: stainless steel (AISI 304)Feed size: max. 5 to 7mmDimensions (WxDxH): 170 x 170 x 350mmWeight: 6.6kgSupply requirements: 230V 50/60HzProtection class DIN EN 60529: IP21Tested to DIN EN IEC 61010-1.

Type PK Cat. No.

M 20M 20 UK

11

9.737 8284.007 942

Optional accessories: M 21 Spare cutter, stainless steel, M 20.1 Grinding chamber, M 23 Star-shaped cutter, M 22 Hard metal cutter

1

Universal mill M 20, accessories and spares2IKA

2

Type Description PK Cat. No.

M 21M 22M 23M 20.1

Spare cutter for M 20*Hard metal cutter (tungsten carbide)Star-shaped cutter (stainless steel)Grinding chamber

1111

9.737 8299.737 8309.737 8319.737 832

*included in delivery

Micro fine mills, Culatti, accessories3

Type PK Cat. No.

Base unitSieve insert 0.2mmSieve insert 0.5mmSieve insert 0.8mmSieve insert 1.0mmSieve insert 1.5mmSieve insert 2.0mmSieve insert 3.0mm

11111111

9.737 8429.737 8439.737 8449.737 8459.737 8469.737 8479.737 8489.737 849

Please order sieve inserts separately.

3

We can supply this

manufactorer’swhole

product range !

Page 32: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

507

5. Sample preparationGrinding/Mills

GENERAL CATALOGUE EDITION 17

E & OE.

Drive unit MF 10 basicUniversal laboratory grinder, comprising powerful drive unit for use with a choice of accessory grinding heads. The usercan choose between the impact grinding head for milling hard, brittle materials (see fig.) and the cutting head forprocessing fibrous material. The maximum granule size output can be set by using various insert sieves (with apertures between 0.25mm and 3mm) placedabove the outlet. There is an NS29 standard ground joint at the outlet for attachment of receiving flasks. Grinding/cutting heads not included.

1

2 3IKA

SpecificationsMotor rating input/output: 1000/500WSpeed range: 3000 to 6500rpm.Tangential speed with impact grinding head: 31.4 m/sec.Tangential speed with cutting head: 22.5 m/sec.Material in contact with product: Stainless steel AISI 316 LPower-on time ON/OFF: 120/130mins.Auto power off: yesDimensions with grinding head (WxDxH): 320 x 300 x 380mmWeight with grinding head: 9.7kgProtection class DIN EN 60529: IP22Supply requirements: 230V 50/60Hz.Tested to DIN EN IEC 61010-1.

Type Description PK Cat. No.

MF 10 basic Drive unit without head 1 9.737 780Optional accessories: MF 10.1 Cutting-grinding head, MF 10.2 Impact grindinghead, MF Sieves

1

9.737 780

2 3

Accessories for microfine grinder MF10 basic, for in-line processes4 5

IKA

Type Description PK Cat. No.

MF 10.1MF 10.2MF 0.25MF 0.5MF 1.0MF 2.0MF 3.0MF 4.0

Cutting headImpact grinding headSieveSieveSieveSieveSieveSieve

11111111

9.737 7819.737 7829.737 7839.737 7849.737 7859.737 7879.737 7889.737 789

4

5

Page 33: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

508

5. Sample preparationGrinding/Mills-Mortars

GENERAL CATALOGUE EDITION 17

E & OE.

Laboratory blender GT 95 NEW!NEW!

Chemical-resistant design.Consisting of:chromium plated, zinc die cast motor unit, 2000ml polycarbonate container with handle, safety lid made of polyurethan.Applications:- for emulsifying; homogenising; grinding; blending; chopping; suspending- for mixing viscous products and pastes- for blending and grinding pigment cakes; biological organs, etc.

All parts can be easily removed and can be autoclaved (individually or fitted ready for use) at 120°C for 20 mins. Themixer is therefore always ready for use and requires little space.

Safety features:- The motor only runs when the lid is properly fitted- The motor stops automatically when the lid is removed- Conforms to CE, complies with the latest EU machinery safety guidelines

Technical data:High grade, chromium-plated zinc die cast motor housing, is easy to clean, robust and does not age. The drive motorhas high temperature stability and stepless control between 500rpm and 17000rpm. The motor is controlledelectronically with an integral switching circuit. It operates separately from the stepless speed control of the soft-startmotor and enables speed stabilisation at full power, i.e. the motor can work at full power over the entire speed range.

1ROTOR

Motor output: 800WWeight (without container): 5.5kgPower: 230V 50/60Hz

Type PK Cat. No.

GT 95 incl. 2000ml polycarbonate container 1 9.571 300

1

Laboratory blender GT 95, accessories NEW!NEW!

Before starting each operation the durability and resistance of all blender materials, e. g.glass, CNS, PP, rubber have to be checked concerning their tolerance against the substancesto process.

Attention: The glass containers are only to use with protective lid. Please order separately.

2ROTOR

2

Description PK Cat. No.

2l stainless steel container HighPower, with lid and knife kit2l polycarbonate container HighPower, with lid and knife kit125ml glass container without baffles, without lid250ml glass container without baffles, without lid500ml glass container without baffles, without lid1000ml glass container without baffles, without lid1000ml glass container with baffles, without lidPlexiglas protective lid incl. hold down weight for 125-1000ml containers

11111111

7.631 2059.571 3089.571 3019.571 3029.571 3039.571 3049.571 3059.571 310

LLG-Mortars only, porcelain, inside rough NEW!NEW!

DIN 12906

3

Capacity Height Ext.diam.

PK Cat. No.

ml mm mm501102575220325

425032466471

811006091

125144

111111

6.227 1496.232 5779.164 4109.164 4119.164 4129.164 413

3

Page 34: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

509

5. Sample preparationGrinding/Mortars

GENERAL CATALOGUE EDITION 17

E & OE.

LLG- Pestle only, porcelain, rough NEW!NEW!1

Headdia.

Length PK Cat. No.

mm mm1526233744

5210384

132158

11111

6.227 1506.232 5749.164 4209.164 4219.164 422

1

Mortars only, porcelainTo DIN 12906. With spout, pestle not supplied. Glazed externally. Inside rough.

2Haldenwanger

Capacity Int.dia.

PK Cat. No.

ml mm70170400700100026006000

6590

130150180240330

1111111

9.164 2069.164 2099.164 2129.164 2159.164 2189.164 2259.164 235

2

Pestles only, porcelainTo DIN 12906. With glazed handle. Unglazed grinding surface.

3Haldenwanger

Nominaldia.

Headdia.

PK Cat. No.

mm mm6390125150180

2430364255

11111

9.164 3069.164 3099.164 3129.164 3159.164 318

Nominal size = mortar internal diameterSpecial sizes available on request.

3

Mortar with pestle,PorcelainUnglazed, with wooden handled pestle.

4

Ext.diam.

PK Cat. No.

mm115135150

111

9.164 3739.164 3749.164 375

4

Mortars and pestles, MFWhite. Melamine formaldehyde (MF). With spouted mortar. Resistant to boiling.Autoclavable at 121°C.

5BRAND

Dia. Height PK Cat. No.mm mm125150

8090

11

9.164 3559.164 357

5

Mortars and pestles, AgateAgate. Polished. Standard quality. Other sizes available on request.

6

Capacity Ext.diam.

Int.dia.

PK Cat. No.

ml mm mm92550100

5075

100125

406085

100

1111

9.164 0509.164 0759.164 1009.164 125

6

Length

mm115135150175210

Page 35: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

510

5. Sample preparationGrinding/Mortars-Sieving/Sieve shakers

GENERAL CATALOGUE EDITION 17

E & OE.

Mortar, stainless steelMortar and pestle head are both made from stainless steel.

1Bochem

Description Capacity PK Cat. No.ml

MortarPestle

250 11

6.900 1196.079 568

1

Analytical Sieve ShakersAS 200 basic/digit/control, AS 300 control, AS 450 controlSieve shakers are used in research & development, quality control of raw materials,interim and finished products as well as in production monitoring.

Features:- Sieving with 3D effect- For wet and dry sieving- Short sieving times- Low-noise, maintenance-free

AS 200 basic: favourably priced basic model.

AS 200 digit: powerful comfort model with touch-sensitive keypad, digital display, interval sieving.

AS 200 control: like AS 200 digit, but microprocessor-controlled, with freely selectable intervals and digital vibrationamplitude setting. It can be calibrated and, for the first time, allows 100% reproducible sieving results worldwide, evenif different instruments are used. The AS 200 control has an integrated interface for the evaluation software EasySieve®.At the same time it also offers all the requirements for test materials monitoring according to ISO 9000 ff.

AS 300 control: like AS 200 control; also suitable for sieves up to 315mm diameter and for higher loads.

AS 450 control: like AS 200 control but only suitable for 400mm diam. and 450mm diam. sieves. The optimizedelectromagnetic drive with RETSCH's CET technology allows for an amplitude up to 2.2mm even with maximum loadsup to 25kg. Manual re-sieving is no longer required.

2 3

Retsch

SpecificationsMax. number of fractions (depending on sieve size):AS 200, AS 300: 9/17AS 450: 14/11Movement of sample: orbital with vibrationHeight of sievetowerAS 200, AS 300: up to approx. 450mmAS 450: up to approx. 940mmMax. charge/quantity of sample:AS 200: 3kgAS 300 control: 5kgAS 450: 25kgTimer:AS 200 digit, control, AS 300: digitalAS 200 basic: analog

2

3

Type Measuringrange

Dimensions(W x D x H)

Weight For Sievesizes (diam.)

PK Cat. No.

mm kg mmAS 200 basicAS 200 digitAS 200 controlAS 300 controlAS 450 control

20µm to 25mm20µm to 25mm20µm to 25mm36µm to 40mm20µm to 125mm

400 x 350 x 230400 x 350 x 230400 x 350 x 230400 x 400 x 235715 x 435 x 630

30303035

220

100 / 150 / 200 / 203100 / 150 / 200 / 203100 / 150 / 200 / 203100 / 150 / 200 / 203 / 305 / 315400 / 450

11111

9.739 2239.739 2249.739 2739.739 2419.739 277

Page 36: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

511

5. Sample preparationSieving/Sieve shakers

GENERAL CATALOGUE EDITION 17

E & OE.

Analytical Sieve Shakers AS 400 control, AS 200 tap/ jet NEW!NEW!

AS 400 control:The AS 400 control is used for the sieving of dry goods with test sieves of a diameter upto 400mm. The uniform, horizontal circular motion ensures exact separation of the product to be sieved.

Features:- Sieving with circular sieving motion according to DIN 53477- Free digital adjustment of all process parameters (time, speed or sieve acceleration, interval)- Memory for up to 9 SOPs- Integrated interface for evaluation software EasySieve®

Electrical supply data: 100-240 V, 50/60 Hz

The clamping devices of AS 200 and AS 300 are also suitable for the AS 400.

AS 200 tap:For sieve analysis of certain products such as activated carbon, abrasives, coal, spices and diamonds, as specified in thecorresponding standards.

Features:- Horizontal, circular sieving motion with vertical taps- Suitable for dry sieving- Robust and maintenance-free

Electrical supply data: different voltages, 1-phase

AS 200 jet:The air jet sieving machine AS 200 jet is particularly suitable for light materials with particle sizes in the lower micronrange which tend to agglomerate.

Features:- Open Mesh Function to reduce the number of near-mesh particles- Operation with standard Retsch sieves, 203 mm (8") diameter, 1" or 2" high- Adapter for 200mm sieves optional- Free manual (standard) or automatic (accessory) pressure regulation- High flexibility through adjustable nozzle speed- Memory for up to 9 SOPs, additional Quick Start mode

Electrical supply data: 100-240 V, 50/60 Hz

Please order clamping devices (except AS 200 tap), sieves and collecting pans separately.

Retsch

SpecificationsMax. number of fractions (depending on sieve size):AS 400 control: 7/9/17AS 200 tap: 7/13AS 200 jet: 1 (2 with cyclone)Movement of sample:AS 400 control: circularAS 200 tap: circular with tapsAS 200 jet: dispersion by air jetHeight of sievetowerAS 400 control: up to approx. 450mmAS 200 tap: up to approx. 350mmAS 200 jet: up to approx. 50mmMax. charge/quantity of sample:AS 400 control: 15kgAS 200 tap: 6kgAS 200 jet: 0.3 to 100gTimer: digital

1

9.739 242

2

9.739 276

3

6.238 239

123

Type Measuringrange

Dimensions(W x D x H)

Weight For Sievesizes (diam.)

PK Cat. No.

mm kg mmAS 400 controlAS 200 tapAS 200 jet

45 µm to 63 mm20 µm to 25 mm10 µm to 4 mm

540 x 507 x 260735 x 530 x 675*460 x 305 x 288

7092*14

100 /150 / 200 /203 / 305 / 315 / 400200 / 203203

111

9.739 2429.739 2766.238 239

*with sound protection cabinet

Page 37: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

512

5. Sample preparationSieving/Sieve shakers

GENERAL CATALOGUE EDITION 17

E & OE.

Acessories for AS 200 jet NEW!NEW!

Retsch

Description PK Cat. No.

Vacuum cleaner, 230V, 50/60Hz (other electrical versions available)Filter bags for industrial vacuum cleanerCyclone with collector (250ml wide-mouth bottle)Automatic vacuum regulationAdapter and lid for analysing sieves 200 x 50mm and 200 x 25mm

15111

9.739 6009.739 2949.739 6019.739 2969.739 253

Software EasySieve® for Sieve Shakers AS control/AS 200 tap/AS jet NEW!NEW!

Software for particle size analyses.

Features:- Automatic registration, evaluation and administration of measurement data- Logical design, self-explanatory- Measurement protocol in accordance with standards- Easy selection and configuration of common analytical scales- English and German- For automatic control of sieve shakers AS 200 control, AS 300 control, AS 450 control, AS 400 control, AS 200 tap,

AS 200 jet- For Windows® 2000/XP/Vista

1

Retsch

Type PK Cat. No.

EasySieve® Single-user-licence, incl. adapter RS232-USBAdapter RS232-USB

11

6.238 9279.739 250

1

Clamping device for Sieve Shakers AS series NEW!NEW!

Retsch

For Description PK Cat. No.

AS 200 + AS 300 + AS 400AS 200 + AS 300 + AS 400AS 200 + AS 300 + AS 400AS 300 + AS 400AS 300 + AS 400AS 200AS 200AS 200AS 300AS 300AS 400AS 400AS 450AS 450AS 450AS 450

Clamping device, comfort, for 200/203mm dia. sievesClamping device, standard, for 200/203mm dia. sievesClamping device economy for 100/150/200/203mm dia. sievesClamping device, standard, for 305/315mm dia. sievesClamping device, comfort, for 305/315mm dia. sievesUniversal clamping device, comfort, for 100/150/200/203mm dia. sievesUniversal clamping device, standard, for 100/150/200/203mm dia. sievesUniversal wet sieving clamping device, standard, for 100/150/200/203mm dia. sievesWet sieving clamping device, standard, for 305mm dia. sievesWet sieving clamping device, comfort, for 305mm dia. sievesClamping device, comfort, for 400mm dia. sievesClamping device, standard, for 400mm dia. sievesClamping device, standard, for 400/450mm dia. sievesClamping device, comfort, for 400/450mm dia. sievesWet sieving clamping device, standard, for 400/450mm dia. sievesWet sieving clamping device, comfort, for 400/450mm dia. sieves

1111111111111111

9.739 2269.739 2279.739 2289.739 2619.739 2609.739 2299.739 2309.739 2319.739 2516.232 8289.739 2659.739 2669.739 2629.739 2679.739 2689.739 269

Other accessories, such as sieve lids and intermediate receivers, are available on request.

Sieve Receivers, stainless steelStainless steel. In accordance to DIN ISO 3310-1 C and ASTM E 11-95. Retsch

Description PK Cat. No.

100mm dia., with outlet200mm dia., without outlet200mm dia., with outlet203mm dia., without outlet203mm dia., with outlet

11111

9.739 2379.739 2359.739 2369.739 2399.739 240

Other collecting pans are availlable on request.

Sieving aidsFor difficult to separate materials which require dry sieving. Different aids are usedaccording to mesh size.

2Retsch

Type PK Cat. No.

Steatite ball, 6mm dia., 150gNylon brushesVulkollan cube 12 x 12 x 12mmRubber ball, 20mm dia.Agate ball, dia. 10mmTest sieve rack for max. 10 sieves up to 203mm dia., 50mm height

11

105

101

9.739 2389.826 1319.826 1329.826 1339.826 1349.739 243

2

Page 38: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

513

5. Sample preparationSieving/Sieve shakers

GENERAL CATALOGUE EDITION 17

E & OE.

Test sieve sets for Sieve Shakers AS series

Retsch

For Dia. Description PK Cat. No.mm

AS 200

AS 300

AS 400

200

305

400

Sieve set, mesh 45µm, 63µm, 125µm, 250µm, 500µm, 1mm, 2mm, 4mm, with receiverSieve set, mesh 630µm, 1.25mm, 2.5mm, 5mm, 10mm, 20mm, 31.5mm, with receiverSieve set, mesh 500µm, 1mm, 2mm, 5mm, 10mm, 20mm, with receiver

1

1

1

9.739 255

9.739 256

9.739 257

Other accessories, such as sieve lids and intermediate receivers, are available on request.

Vibratory sieve shaker ANALYSETTE 3 PRO and SPARTANFor quantitative particle size analysis of dry samples and suspensions of all kind by dryand wet sieving with woven test sieves. FRITSCH Sieve Shakers satisfy all requirementsfor accurate and reproducible sieving analysis and perform automatic sieve analysis with the control and evaluationsoftware AUTOSIEVE, which is delivered free of charge. The top model ANALYSETTE 3 PRO guarantees absolutelyreproducible sieving results due to automatic amplitude control, programme selection, can be integrated into anyquality management system according to DIN EN ISO 9000, has an RS232-interface, to mention only some of itsinnovative and practical features.

1Fritsch

Sieving: dry or wetSieve diameters: 100mm, 150mm, 200mm or 8"Maximum number of sieves: 10 x 50mm (full) or 18 x 25mm (half) heightSieves: woven mesh metal sievesMeasuring range: Dry sieving: 32µm to 63mm

Wet sieving: 20µm to 10mmSample quantity: Dry sieving: up to 2kg (depending on the sample material and sieve used)

Wet sieving: 20 to 100gMeasuring time: Dry sieving: 3 to 20 mins

Wet sieving: 5 to 10 minsPower supply: 100-240V/1~, 50-60HzDimensions (WxDxH): 370 x 400 x 200mmNet weight: 21kg

Type PK Cat. No.

Sieve Shaker ANALYSETTE 3 PROSieve Shaker ANALYSETTE 3 SPARTAN

11

9.826 4029.826 403

Clamping lid, sieve pan and sieves must be ordered separately.

1

Accessories for vibratory sieve shakers, ANALYSETTE 3 PRO and SPARTAN NEW!NEW!

Fritsch

Type For PK Cat. No.

Plexiglas clamping lid for 8" / 200mm dia. sievesClamping lid (without window)for all test sieves up to 200mm / 8" dia.Sieve tensioning system TorqueMaster (incl. clamping lid)Interposed sieve pan made of stainless steel 200mm dia., 50mm heightInterposed sieve pan made of stainless steel 8" dia., 2" heightSieve pan, stainless steel 200mm dia., 50mm highSieve pan, stainless steel 8" dia., 2" highClamping lid, plexiglas with 2 rotation nozzles for test sieves 8" / 200mm dia.Sieve pan, stainless steel with outlet 200mm dia., 50 mm highInterposed sieve ring with 3 nozzles for test sieves 200mm dia.Sieve pan, stainless steel with outlet, 8" dia., 2" highInterposed sieve ring with 3 nozzles for test sieves 8" dia.

Dry sieving

Dry sieving

Dry sieving

Dry sieving

Dry sieving

Dry sieving

Dry sieving

Wet sieving

Wet sieving

Wet sieving

Wet sieving

Wet sieving

1

1

1

1

1

1

1

1

1

1

1

1

9.826 404

9.826 405

9.826 943

9.826 939

9.826 940

9.826 444

9.826 406

9.826 401

9.826 446

9.826 447

9.826 449

9.826 450

Page 39: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

514

5. Sample preparationSieving/Test sieves

GENERAL CATALOGUE EDITION 17

E & OE.

Test SievesWith unique advantages:Retsch has developed an entirely new manufacturing process providing a level of qualityand uniformity in sieve manufacturing which had not previously been attained. Benefits:1. Previously unattained product quality owing to fully automatic production and continuous optical inspection.2. Innovative resistance welding technology guarantees permanently taut wire mesh.3. High level of corrosion resistance and easy to clean owing to the use of high-alloy stainless steel (grades: 316 or 1.4435).4. "one-piece cast" sieve frame and seamless mesh joint prevent cross contamination (no lead flash, no solder, etc.).5. Maximum stability and optimum density of the sieve stack.6. 15% lighter than traditional sieves whilst at the same time having larger sieving area.7. Clear sieve marking and traceability by individual laser engraving on each sieve.

Retsch

Test Sieves, 200 x 50 mm.1Retsch

Mesh size

PK Cat. No.

µm202532363840455053566371758090100106112125140150160180200212224250280300315355400425450500560600630710800850900

111111111111111111111111111111111111111111

9.226 6509.226 6519.226 6529.226 6539.226 6549.226 6559.226 6569.226 6579.226 6589.226 6599.226 6609.226 6619.226 6629.226 6639.226 6649.226 6659.226 6669.226 6679.226 6689.226 6699.226 6709.226 6719.226 6729.226 6739.226 6749.226 6759.226 6769.226 6779.226 6789.226 6799.226 6809.226 6819.226 6829.226 6839.226 6849.226 6859.226 6869.226 6879.226 6889.226 6899.226 6909.226 691

1

Page 40: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

515

5. Sample preparationSieving/Test sieves

GENERAL CATALOGUE EDITION 17

E & OE.

Test Sieves, 200 x 50 mmDIN ISO 3310-1 and BS 410-1. Dimensions (dia. x h): 200mm x 50mm.

1Retsch

Aperture size

PK Cat. No.

mm1.001.121.181.251.401.601.701.802.002.242.362.502.803.153.353.554.004.504.755.005.606.306.707.108.009.009.5010.0011.2012.5013.2014.0016.0018.0019.0020.0022.4025.0026.5028.0031.5035.5037.5040.0045.0050.0053.0056.0063.0071.0075.0080.0090.00100.00106.00112.00125.00

111111111111111111111111111111111111111111111111111111111

9.226 6929.226 6939.226 6949.226 6959.226 6969.226 6979.226 6989.226 6999.226 7009.226 7019.226 7029.226 7039.226 7049.226 7059.226 7069.226 7079.226 7089.226 7099.226 7109.226 7119.226 7129.226 7139.226 7149.226 7159.226 7169.226 7179.226 7189.226 7199.226 7209.226 7219.226 7229.226 7239.226 7249.226 7259.226 7269.226 7279.226 7289.226 7299.226 7309.226 7319.226 7329.226 7339.226 7349.226 7359.226 7369.226 7379.226 7389.226 7399.226 7409.226 7419.226 7429.226 7439.226 7449.226 7459.226 7469.226 7479.226 748

1

Page 41: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

516

5. Sample preparationSieving/Test sieves

GENERAL CATALOGUE EDITION 17

E & OE.

Test Sieves, 200 x 25 mmDIN ISO 3310-1 and BS 410-1. Dimensions (dia. x H): 200mm x 25mm.

1Retsch

Mesh size

PK Cat. No.

µm202532363840455053566371758090100106112125140150160180200212224250280300315355400425450500560600630710800850900

111111111111111111111111111111111111111111

9.226 7509.226 7519.226 7529.226 7539.226 7549.226 7559.226 7569.226 7579.226 7589.226 7599.226 7609.226 7619.226 7629.226 7639.226 7649.226 7659.226 7669.226 7679.226 7689.226 7699.226 7709.226 7719.226 7729.226 7739.226 7749.226 7759.226 7769.226 7779.226 7789.226 7799.226 7809.226 7819.226 7829.226 7839.226 7849.226 7859.226 7869.226 7879.226 7889.226 7899.226 7909.226 791

1

We can supply this

manufactorer’swhole

product range !

Page 42: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

517

5. Sample preparationSieving/Test sieves

GENERAL CATALOGUE EDITION 17

E & OE.

Test Sieves, 200 x 25 mm.DIN ISO 3310-1 and BS 410-1. Dimensions (dia. x H): 200mm x 25mm.

1Retsch

Aperture size

PK Cat. No.

mm1.001.121.181.251.401.601.701.802.002.242.362.502.803.153.353.554.004.504.755.005.606.306.707.108.009.009.5010.0011.2012.5013.2014.0016.0018.0019.0020.0022.4025.0026.5028.0031.5035.5037.5040.0045.0050.0053.0056.0063.0071.0075.0080.0090.00100.00106.00112.00125.00

111111111111111111111111111111111111111111111111111111111

9.226 7929.226 7939.226 7949.226 7959.226 7969.226 7979.226 7989.226 7999.226 8009.226 8019.226 8029.226 8039.226 8049.226 8059.226 8069.226 8079.226 8089.226 8099.226 8109.226 8119.226 8129.226 8139.226 8149.226 8159.226 8169.226 8179.226 8189.226 8199.226 8209.226 8219.226 8229.226 8239.226 8249.226 8259.226 8269.226 8279.226 8289.226 8299.226 8309.226 8319.226 8329.226 8339.226 8349.226 8359.226 8369.226 8379.226 8389.226 8399.226 8409.226 8419.226 8429.226 8439.226 8449.226 8459.226 8469.226 8479.226 848

1

Page 43: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

518

5. Sample preparationSieving/Test sieves

GENERAL CATALOGUE EDITION 17

E & OE.

Test Sieves, 203 x 50 mmDIN ISO 3310-1 and BS 410-1. Dimensions (dia. x H): 203mm x 50mm.

1Retsch

Mesh size

PK Cat. No.

µm202532363840455053566371758090100106112125140150160180200212224250280300315355400425450500560600630710800850900

111111111111111111111111111111111111111111

9.226 8509.226 8519.226 8529.226 8539.226 8549.226 8559.226 8569.226 8579.226 8589.226 8599.226 8609.226 8619.226 8629.226 8639.226 8649.226 8659.226 8669.226 8679.226 8689.226 8699.226 8709.226 8719.226 8729.226 8739.226 8749.226 8759.226 8769.226 8779.226 8789.226 8799.226 8809.226 8819.226 8829.226 8839.226 8849.226 8859.226 8869.226 8879.226 8889.226 8899.226 8909.226 891

1

Page 44: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

519

5. Sample preparationSieving/Test sieves

GENERAL CATALOGUE EDITION 17

E & OE.

Mesh, polyesterThermo-fixed PE mesh with temperature resistance from 75°C to +150°C (short). For long term heating max. 125°C.Resistant to acids but not alkalis.Dimensions: Minimum width 102cm, Length 100cm.

1 2 3

Mesh size

PK Cat. No.

µm156101520304050536070809010010515020025030040050060070080090010001600200030004000

1111111111111111111111111111111

9.068 2109.068 2119.068 2129.068 2139.068 2149.068 2159.068 2169.068 2179.068 2189.068 2199.068 2209.068 2219.068 2229.068 2239.068 2249.068 2259.068 2269.068 2279.068 2289.068 2299.068 2309.068 2319.068 2329.068 2339.068 2349.068 2359.068 2369.068 2379.068 2389.068 2399.068 240

1

2

3

Mesh, Polyamide NEW!NEW!

Thermo-fixed Polyamide (Nylon) mesh is temperature stable from -40°C to +115°C. Dry in water from 95°C to 100°C.Stability in acids is limited and dependant on concentration and temperature. Nylon exhibits outstanding stability inalkalis, including sodium and potassium solutions. Its chemical behaviour with respect to organic solvents is moderateto good. Minimum mesh width: 102cm, Length: 1m

4 5 6

Mesh size

PK Cat. No.

µm15610152030405060708090100125150200250300400500600700780800900950100011501800200033004000

111111111111111111111111111111111

9.068 2769.068 2779.068 2789.068 2799.068 2809.068 2819.068 2829.068 2839.068 2849.068 2859.068 2869.068 2879.068 2889.068 2899.068 2909.068 2919.068 2929.068 2939.068 2949.068 2959.068 2969.068 2979.068 2989.068 3089.068 2999.068 3009.068 3019.068 3029.068 3079.068 3039.068 3049.068 3059.068 306

4

5

6

Page 45: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

520

5. Sample preparationSieving/Sample divider

GENERAL CATALOGUE EDITION 17

E & OE.

Sample Divider PT 100Rotary tube divider for the representative sample division with an extremely high divisionaccuracy. Rapid and easy handling of sample vessels thanks to quick-release clamps.

Specifications:- Feed size: to 10mm- Number of samples: 8 (6 or 10 heads also available on request)- Throughput/charge: 5000ml- Dimensions (WxDxH): 400 x 347 x 840mm- Weight: approx. 34kg- Supply requirements: 230V, 50Hz

Supplied with: PT 100 incl. deviding head with 8 quick-release sample outlets, vibratory feeder DR 100/40 and 10sample bottles (250ml).

1Retsch

Type PK Cat. No.

PT 100 1 9.739 107

1

Vibratory Feeder DR 100For the continuous, automatic material conveyance to, and feeding of, sample dividers,mills, balances or analytical and measuring apparatus.

Specifications:- Weight: approx. 10kg- Supply requirements: 220-240V, 50Hz.

DR 100 supplied with: sample divider attachment, with plug-in, 40mm wide chute and mounting plate.Accessories: Further hoppers, chutes and vibrating tubes made of stainless steel available on request.

2Retsch

Type PK Cat. No.

Vibrationary feeder DR 100 1 9.739 110

2

Rotating Tube Divider PK 1000 NEW!NEW!

For removal of one or several representative samples. Fixed or adjustable division ratio.

Specifications:- Suitable for pourable powder and granular bulk goods- Feed size: up to 10mm, throughput/charge: 30L- Number of samples: 1, 2, 3, 4 and 6 (depending on lower cone selected)- Dimensions (WxDxH): 560 x 700 x 1150mm- Weight: approx. 47kg, supply requirements: 220-240V, 50Hz

Supplied with: rotating tube divider with bottom cone and one adjustable sample outlet (max. division ratio 1:5),vibratory feeder DR 100/75 and hopper, 10 x 500ml wide-mouth sample bottles and 1 x 30L reject collector.For Art. No. 9.739 108 please order cone separately.

3Retsch

3

Type PK Cat. No.

Rotary divider PK 1000, incl. vibratory feeder and lower cone 1:5Bottom cone for PK 1000, 1 adjustable sample outletsBottom cone for PK 1000, 2 adjustable sample outletsBottom cone for PK 1000, 3 adjustable sample outlets

1

111

9.739 115

6.241 1856.241 1866.241 187

Page 46: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

521

5. Sample preparationSieving/Sample divider

GENERAL CATALOGUE EDITION 17

E & OE.

Sample Splitters, RT seriesTo provide separation of pourable powders and bulk materials on site and in thelaboratory. Operates independently of mains supply. Available in 6 sizes. Number ofsamples: 2.

1Retsch

Type Feed size

up to

MaximumThroughput/Charge

Dimensions(W x D x H)

Weight PK Cat. No.

mm mm kgRT 6.5RT 12.5RT 25RT 37.5RT 50RT 75

6.312.525.037.5

5075

5 L5 L16 L16 L16 L16 L

300 x 270 x 250300 x 270 x 250620 x 420 x 260620 x 420 x 260620 x 420 x 260620 x 420 x 260

3.503.50

21.5021.5021.5021.50

111111

9.739 2009.739 2019.739 2029.739 2039.739 2049.739 205

1

Rotary cone sample divider LABORETTE 27Creates the optimal basis for reliable analysis of a representative sample. Representativesamples division is the foundation for every precise analysis. The rotary cone sampledivider LABORETTE 27 achieves due to its unique combination of three methods previously unheard of dividingprecision. Variable division ratios and the design in several variants guarantee adaptation to a wide range ofapplications with a dividing accuracy of up to 99.9%. For optimal sample feeding the vibratory feeder LABORETTE 24(optional) is recommended.

2Fritsch

Division: of solid samples and suspensions, without modificationDividing ratio: 1:8, 1:10, 1:30Number of sub-sets: 8, 10, 3Max. particle size: 10mm, 2.5mmMax. feed volume: 4000ml, 2500ml, 300mlSample bottle capacities: 15, 20, 25, 30, 250, 500mlPower supply: 230V/1~, 50-60HzDimensions (WxDxH): 270 x 450 x 460mmNet weight: 8kg

Type PK Cat. No.

Rotary cone sample divider LABORETTE 27 1 9.738 310Instrument also available in other voltages.Dividing heads must be ordered separately.

2

Accessories for rotary cone sample divider LABORETTE 27Fritsch

Dividing ratio

Material Sample bottles PK Cat. No.

ml1:81:81:101:101:301:30

POM plasticaluminiumPOM plasticaluminiumPOM plasticaluminium PTFE-coated

5005002502501515

111111

9.738 3169.738 3139.738 3179.738 3189.738 3199.738 314

All dividing heads are delivered inclusive of sample bottles and funnels.

Page 47: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

522

5. Sample preparationMixing, Homogenisation/Dispersers

GENERAL CATALOGUE EDITION 17

E & OE.

Homogeniser SilentCrusher SSmall model for use in microbiology

- Featuring a speed range up to 75000rpm the SilentCrusher S is by far the fastest and most silent homogenizer in theworld

- To protect your sample effectively from any thermal damage the drive system switches off automatically after 90 seconds

- Easy to use: Simply drop the reaction vessel into the drive system and it will start automatically- If required, you can easily cool down samples by using ice or cold water. Three discs are included in every shipment

which allow for height positioning of any cooling tray- Ideal for homogenising sample quantities from 0.8ml to 10ml and a viscosity up to 5000mPa s- Choose from three different sterilisable generators: 3mm or 7mm, these options will certainly include a generator that

works best for your needs

1Heidolph

Technical DataInput Power: 24WDimensions:Drive (dia. x H): 125 x 197mmPower Supply Pack (W x H x D): 106 x 30 x 65mmVoltage: 100-240V, 47-63HzProtection Class: IP30Weight: 0.8kg

Type PK Cat. No.

SilentCrusher S 1 9.570 135

1

Generators Homogeniser SilentCrusher S- Homogenise with high quality generators made of corrosion resistant stainless steelAISI 316

- SilentCrusher generators are easily disassembled for quick and convenient cleaning; ideal for multiple samples- Generators are autoclavable up to 130°C or allow for air sterilization up to 180°C- To ensure years of unlimited usage the ball bearings and the attachment for the generators are made of chemically

resistant PTFE- 10 Polypropylene vessels which perfectly fit your generator of choice are included as a standard

2Heidolph

2

Type Stator dia.

Shaft lengthmin.

Outputparticlesize

Capacity Recommen-dationsfor use

PK Cat. No.

mm mm mm ml3 F5 F7 F

3.35.07.0

263855

<0.4<0.4<0.4

0.8 to 1.02.0 to 4.06.0 to 10.0

Reaction tubesTest tubesTest tubes

111

9.570 1369.570 1379.570 138

Page 48: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

523

5. Sample preparationMixing, Homogenisation/Dispersers

GENERAL CATALOGUE EDITION 17

E & OE.

Homogeniser SilentCrusher MModel for all standard applications

- With a speed range up to 26000rpm the SilentCrusher M is the most silent homogeniser in the world- Large digital display allows for easy setting and read out even from a distance- Speed can be adjusted individually from 5000rpm to 26000rpm- Your first choice for any quantities from 0.8ml to 2000ml- Allows for any viscosity up to 5000mPa s- Choose from 13 different sterilisable generators: From 6mm to 22mm diameter you will find options which meet your

specification

1Heidolph

Type PK Cat. No.

SilentCrusher M 1 9.570 140

1

Generator for Homogeniser SilentCrusher M- Homogenise with high quality generators made of corrosion resistant stainless steelAISI 316

- SilentCrusher generators are easily disassembled for quick and convenient cleaning, ideal for multiple samples- Generators are autoclavable up to 130°C or allow for air sterilisation up to 180°C- Due to interchangeable ball bearings and chemically resistant PTFE, all bearings are designed for years of unlimited

usage- For larger samples it may be necessary to pre-crush samples. In this case we recommend generators which feature

additional sprockets (except for 18G, 18DG, 22G)- For applications under vacuum down to 20mbar or pressure up to 6 bar we recommend our sealed generators

2Heidolph

2

Type Stator dia.

Rotor dia.

Slitwidth

Length Capacity Outputparticlesize

PK Cat. No.

mm mm mm mm ml mm6 F8 F8 DF*12 F12 G12 DF*12 DG*18 F18 G18 DF*18 DG*22 F22 G

5.38.28.2

12.012.012.012.018.018.018.018.022.022.0

3.206.606.609.009.009.009.00

12.5012.5012.5012.5016.5016.50

0.60.60.60.62.00.62.01.53.01.53.01.53.0

608075

120120115115180180175175180180

0.8 to 303 to 503 to 5025 to 25025 to 25025 to 25025 to 250100 to 1500100 to 1500100 to 1500100 to 1500100 to 2000100 to 2000

< 0.4< 0.4< 0.4< 2.0< 2.0< 2.0< 2.0< 4.0< 4.0< 4.0< 4.0< 4.0< 4.0

1111111111111

9.570 1399.570 1419.570 1429.570 1439.570 1449.570 1459.570 1469.570 1479.570 1489.570 1499.570 1509.570 1049.570 105

* For applications under pressure or vacuum (max. pressure 6 bar/min. vacuum 20 mbar).

We can supply this

manufactorer’swhole

product range !

Page 49: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

524

5. Sample preparationMixing, Homogenisation/Dispersers

GENERAL CATALOGUE EDITION 17

E & OE.

Accessories for Homogeniser SilentCrusher MPlate standFootprint: 180 x 245mm, Shaft: diameter 13mm, Length: 600mm, Weight: 1.8kg

Cross sleeve SPlease note, 2 clamps are required to attach the SilentCrusher M and the vessel holding bracket.

Vessel holding bracket incl. 2 retainer ringsFor different vessels diameter 20mm to 105mm

1Heidolph

Type PK Cat. No.

Plate standCross sleeve SVessel holding bracket incl. 2 retainer rings

111

9.570 1519.570 1529.570 153

1

Page 50: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

525

5. Sample preparationMixing, Homogenisation/Dispersers

GENERAL CATALOGUE EDITION 17

E & OE.

Disperser System Ultra-Turrax® Tube Drive

Disperse, stir, and grind using a single drive unit. Patented disposable disperser systemfor volumes from 2ml to 50ml with hermetically sealable, disposable sample tubes.Provides protection and safety from: Infectious samples, toxic substances, strong-smelling materials.- no possibility of cross-contamination- suitable for individual or serial operations- increased safety due to low voltage (24V) power- chemically resistant plastic containers- anti-locking function- patented- worldwide service guaranteed by Ika®

ULTRA-TURRAX® Tube Drive Workstation supplied with:Ultra Turrax® Tube Drive, 2 x DT-20 dispersing tubes incl. hook for removing the rotor-stator unit, 2 x ST-20 stirringtubes, 2 x BMT-20 G/S Ball-mill-tubes (with glass balls/stainless steel balls, respectively), power supply and 1 xremoval hook for removal the rotor-stator unit.Dispersing tubes (20ml and 50ml) with pierceable membrane and γ-sterilized are available on request.

ULTRA-TURRAX® Tube Drive control Workstation supplied with:ULTRA-TURRAX® Tube Drive control , 1 x ST-20, 1 x DT-20 incl. 1 removal hook for removal the rotor-stator unit, 2 x BMT-20 G/S, power supply.

4

IKA

SpecificationsMotor rating input/outputULTRA-TURRAX® Tube Drive: 20/17 WULTRA-TURRAX® Tube Drive control: 28/17 WVolume: 2 to 50mlViscosity max.: 5000mPasSpeed rangeULTRA-TURRAX® Tube Drive: 300 to 6000rpmULTRA-TURRAX® Tube Drive control: 400 to 800rpmNoise without element: 50dB(A)TimerULTRA-TURRAX® Tube Drive: 1 to 59sec. (300 to 6000rpm)

1 to 29min. (300 to 4000rpm)ULTRA-TURRAX® Tube Drive control: 1 sec. up to 30min. (continuously adjustable)Protection class according to DIN EN 60529: IP20Supply requirements: 100 - 240V 50/60HzTested to DIN EN IEC 61010-1.

1

9.570 500

2

9.570 506

3

4.008 150

4

123

Description Dimensions(W x D x H)

Weight PK Cat. No.

mm kgUltra-Turrax® Tube DriveUltra-Turrax® Tube Drive WorkstationULTRA-TURRAX® Tube Drive controlULTRA-TURRAX® Tube Drive control WorkstationDT-20 Dispersing TubeST-20 Stirring TubeBMT-20 G Ball-Mill-Tube (with glass balls)BMT-20 S Ball-Mill-Tube (with stainless steel balls)

100 x 160 x 40100 x 160 x 40122 x 178 x 54122 x 178 x 54

0.75

0.90

1111

25252525

9.570 5009.570 5064.008 1504.008 1359.570 5079.570 5089.570 5099.570 510

50 ml tubes available on request.

Page 51: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

526

5. Sample preparationMixing, Homogenisation/Dispersers

GENERAL CATALOGUE EDITION 17

E & OE.

Disperser/ Homogenizer Miccra D-9Light, compact, strong, with extremely high-speed. These are the features of thisextraordinary drive which fits to all common laboratory applications from soil technologyto cell biology. A unique volume range from 0.1 up to 20000ml can be handled with this unit with unequalled results.

Art Prozess- & Labortechnik

SpecificationsPower input: 850WPower output: 495WVoltage/Frequency: 200 - 240V 50/60HzVolume range: 0.1 to 20000mlSpeed range: 11000 to 39000rpmSpeed adjustment: YesElectronic stabilizer: YesWeight: approx. 1.4kgDimensions: 66 x 66 x 232mmProtect.syst./safety class: IP 20/IIOverload protection: Thermal SensorSafety switch: YesSmooth start: YesPermissible ambient temp.: 5 to 50°CPermissible ambient humid.: up to 85%CE label: YesWarranty: 5 years

Type PK Cat. No.

Miccra D-9 1 4.006 938

Hand-held dispersing and homogenizing device MICCRA D-15Although its size is small,this drive is a real high power unit. The successor of theMICCRA D-13, with its integrated constant electronics and its more powerful 1.520 Wattmotor works out large volumes, keeping a constant speed even with increasing viscosities.

2Art Prozess- & Labortechnik

Technical specificationPower input: 1520WPower output: 900WVoltage/Frequency: 200 - 240V 50/60Hz

110 - 120V 50/60HzVolume range: 100 - 50000mlSpeed range: 8800 -33600rpmSpeed adjustment: YesElectronic stabilizer: YesWeight: 2.0kgDimensions: 70 x 70 x 270mmProtect.syst./safety class: IP 20/IIOverload protection: Thermal Sensorsafety switch: YesSmooth start: YesPermissible ambient temp.: 5 - 50°CPermissible ambient humid.: up to 85% R.H.CE label: YesWarranty: 5 years

Type PK Cat. No.

Miccra D-15 1 4.006 939

2

1 1

Page 52: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

527

5. Sample preparationMixing, Homogenisation/Dispersers

GENERAL CATALOGUE EDITION 17

E & OE.

Dispersing tools Pico Series, 316 L SSOur "Pico" tool range applies particularly for smaller sample quantities in the bio andgenetic sample preparation,especially in PCR diagnostics. Whether you would like to extract RNA or cut up fabric for other analysis procedures.The tools of the Miccra biotech range will accelerate and simplify your work without heating up the sample.They are also reliable aids for cell determinations and enzyme studies. Combined with the high revving Miccra D-1 andD-9 drives you will receive excellent results within seconds, which have been confirmed to us by various BSElaboratories.

1Art Prozess- & Labortechnik

Technical data:Material: 316 L SSRotor type: Cutting rotor

Type Stator type

Outer diameter

Tool lenght

PK Cat. No.

mm mm mmDS-5k-1*DS-8/P**DS-14/P**

5mm ZkS8mm ZkS14mm ZkS

5mm8mm14mm

120mm155mm200mm

111

4.006 9406.222 3204.006 942

* Hybrid bearing**PTFE (plain white)

1

Ultra-Turrax® T10 basicCompetitively priced dispersing instrument for volumes of 0.5ml to 100ml. A wide speedrange allows you to work at high circumferential speeds.- maintains speed with various media thanks to high performance 125W drive- ideal for manual operation thanks to its light weight and ergonomic form- extremely mobile thanks to direct mains operation (no transformer required)- stainless steel dispersing elements (5mm, 8mm and 10mm diameter) can be cleaned quickly and easily as they can

be dismantled without tools- plastic disposable dispersing elements in two sizes, particularly suitable for PCR analysis- quick-release coupling makes changing the dispersing elements easy

Supplied with: storage case to hold drive and accessory dispersing elements (to be ordered separately), spare seals andR 200 clamp

2IKA

SpecificationsMotor rating input/output: 125/75WWorking volume range (H2O): 0.5 to 100mlmaximum viscosity: 5000mPasSpeed range: 8000 to 30000rpmSpeed adjustment: steplessSpeed display: Scale (1 to 6)Clamping rod diameter/length: 8 mm/100mmDimensions: 46 x 57 x 201mmWeight: 0.4kgProtection rating to DIN EN 60529: IP30Tested to DIN EN IEC 61010-1.

Type PK Cat. No.

T10 basic Ultra-Turrax® 1 9.570 843

2

Dispersing heads Ultra Turrax® T 10 basicDispersing heads, plastic: Autoclavable. Dispersing heads, stainless steel: Ultimate fineness emulsions 1 to 10µm andsuspensions 5 to 25µm, sterilisable by all methods.

34567

IKA

Type Material Diam. rotor / stator

Max.immersion

depth

Workingvolume

PK Cat. No.

mm mm mlS 10 D - 7G - KS - 65S 10 D - 7G - KS - 110S 10 N - 5 GS 10 N - 8 GS 10 N - 10 G

PC, PSUPC, PSUPTFE, AISI 316LPTFE, AISI 316LPTFE, AISI 316L

4.8 / 74.8 / 73,8 / 56,1 / 87,6 / 10

50907595

100

1 to 201 to 400.5 to 101 to 501 to 100

2525111

9.570 8759.570 8777.631 9646.225 6146.225 477

3

9.570 875

4

9.570 877

5

7.631 964

6

6.225 614

7

6.225 477

Accessories please see page 531

Page 53: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

528

5. Sample preparationMixing, Homogenisation/Dispersers

GENERAL CATALOGUE EDITION 17

E & OE.

Ultra-Turrax® T18 basic NEW!NEW!

- For volumes of 1ml to 1500ml (H2O)- a broad operating range enables you to work at high rotational speeds- electronic speed control- electronic overload protection- quick release button for removing dispersing element- T18 is equipped with a connection for a revolution counter

1IKA

SpecificationsMotor rating input/output: 500/300WWorking volume range (H2O): 1 to 1500mlMaximum viscosity: 5000mPasSpeed range: 3500 to 24000rpm.Speed adjustment: steplessSpeed display: Scale (1 to 6)Noise without dispersing element: 73 dB (A)Clamping rod diameter/length: 13mm/175mmDimensions (WxDxH): 65 x 80 x 240mmWeight: 1.6kgProtection rating to DIN EN 60529: IP20Supply requirements: 230V 50/60HzTested to DIN EN IEC 61010-1.

1

Type PK Cat. No.

Ultra-Turrax® T18 basicT 18 basic ULTRA-TURRAX® Package (incl. S 18 N - 19 G)

11

9.570 8409.570 846

Optional accessories: Dispersing heads, stands: R 1825, R 1826, R 1827, R 182 bosshead, RH 3 Strap clamp

Dispersing heads for Ultra Turrax® T18 basicPlastic dispersing heads: AutoclavableStainless steel dispersing heads: Ultimate fineness emulsions 1 to 10µm andsuspensions 10 to 50µm, sterilisable by all methods.

2IKA

2

Type Diam. rotor / stator

Max.immersion

depth

Workingvolume

Material PK Cat. No.

mm mm mlS 18 D-10 G-KSS 18 D-14 G-KSS 18 N-10 GS 18 N-19 G

6.75 / 109.5 / 14

858570

170

10 to 10010 to 5001 to 10010 to 1500

PC, PEEKPC, PEEKPTFE, AISI 316LPTFE, AISI 316L

101011

9.570 8559.570 8579.570 8419.570 842

Homogenizer, Ultra-Turrax® T 25 digitalWith choice of 15 easily interchangeable dispersing heads, volume range 1ml to 2000ml.Also available are 5 additional grinding rotors, 3 seal types and several special dispersingheads. Please order the appropriate accessory heads separately. Applications range from the homogenisation of sewagesamples to use in laboratory reactions, from vacuum/pressure dispersing tasks to sample preparation in medicaldiagnostics. Supplied with interface for rev counter DZM control.

3IKA

Specifications:Motor ratinginput/output: 500/300WVolume range (H2O): 1 to 2000LViscosity max.: 5000mPasSpeed range (under load): 3500 to 24000rpm.Speed control: steplessSpeed display: LEDNoise without element: 73dB (A)Dimensions (WxDxH): 65 x 80 x 240mmSupply requirements: 230 V 50/60Hz.Weight: 1.6kgProtection class DIN EN60529: IP20Tested to DIN EN IEC 61010-1.

Type PK Cat. No.

T 25 digital ULTRA-TURRAX®

T 25 digital ULTRA-TURRAX® UK11

9.570 8456.230 570

3

Page 54: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

529

5. Sample preparationMixing, Homogenisation/Dispersers

GENERAL CATALOGUE EDITION 17

E & OE.

Dispersing heads for T25 basic Ultra-Turrax®

Plastic dispersing heads: Autoclavable.Stainless steel dispersing heads: Ultimate fineness: emulsions 1µm to 10µm and suspensions 5µm to 50µm, sterilisable by allmethods.

12

3

IKA

Type Diam. rotor / stator

Max.immersion

depth

Workingvolume

Material PK Cat. No.

mm mm mlS 25 D-10 G-KSS 25 D-14 G-KSS 25 N - 8 GS 25 N - 10 GS 25 N - 18 GS 25 NK - 19 GS 25 KV - 25 GS 25 N - 25 GS 25 N - 25 FS 25 KV - 25 F

6.75 / 109.5 / 146.1 / 87.5 / 1012.7 / 1812.7 / 1917.0 / 2517.0 / 2518.0 / 2518.0 / 25

85858585

165165225165165225

10 - 10010 - 5001 - 501 - 10010 - 150025 - 150050 - 200050 - 2000100 - 2000100 - 2000

PC, PEEKPC, PEEKPTFE, AISI 316LPTFE, AISI 316LPTFE, AISI 316LPTFE, AISI 316LFFPM / SIC, AISI 316LPTFE, AISI 316LPTFE, AISI 316LFFPM / SIC, AISI 316L

101011111111

9.570 8599.570 8619.571 0989.571 2079.571 1199.571 1219.571 1989.571 2009.571 2019.571 199

Further dispersing heads are available on request.

1

9.570 859

2

9.570 861

3

9.571 200

High-power homogenizer, Ultra Turrax® T50 basicHigh-performance dispersing instrument for volumes from 0.25L - 30L (H2O).- Three types of shaft bearings- Several rotor-stator configurations- Agitator shaft R50 allows the use of the T50 basic as a "high-speed stirrer" (not included in delivery)- Infinitely variable speed control, for continuous operation- Reproducible operations due to constant speed even with viscosity changes- Large selection of dispersing elements- Plug-in connectors facilitate exchange of dispersing elements- Electronic safety circuit and smooth start- As standard, the T50 basic is equipped with a connection for the revolution counter

4IKA

SpecificationsMotor rating, input/output: 1100/700WVolume range (water): 0.25 to 30LMax. viscosity: 5000mPasSpeed adjustment: steplessSpeed range: 500 to 10000rpm.Speed stability: 1%Diameter/length of extension arm 16 mm/220mmOverload protection: yesSpeed display: scaleNoise without dispersing element: 72 dB (A)Dimensions (WxDxH): 125 x 120 x 367mmWeight: 6kgProtection class DIN EN 60529: IP20Supply requirements: 230V 50/60Hz.Tested to DIN EN IEC 61010-1.

Type PK Cat. No.

T 50 basic ULTRA-TURRAX®

T 50 basic ULTRA-TURRAX® UK11

9.570 8504.008 129

Optional accessories: Dispersing heads, Stands: R 2722, R 2723, R 271 Bosshead, RH 5 Strap clamp

4

Accessories please see page 531

Page 55: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

530

5. Sample preparationMixing, Homogenisation/Dispersers

GENERAL CATALOGUE EDITION 17

E & OE.

Dispersing heads for T50 basic ULTRA-TURRAX®

Stainless steel dispersing heads

123

IKA

Type Diam. rotor / stator

Max.immersion

depth

Workingvolume

Ult. finenesssuspensions / emulsions

Material PK Cat. No.

mm mm l µmS 50 N - G 45 G*S 50 N - G 45 M*S 50 N - G 45 F*

36,0 / 4540.5 / 4540.0 / 45

250250250

0.5 to 200.5 to 150.25 to 10

40 to 10025 to 5010 to 30

PTFE, AISI 316LPTFE, AISI 316LPTFE, AISI 316L

111

9.570 8829.570 8869.570 896

* sterilisable by all methodsFurther dispersing heads are available on request.

1

9.570 882

2

9.570 886

3

9.570 896

Special dispersing heads for disperser T50 basicR 50 "high speed" stirring shaftUsing the R 50 stirring shaft, the T50 basic is quickly converted into a high speed stirrer. 700W power and 10000rpm areprovided for rapid mixing, dissolving, and breaking up pigment agglomerates. The conical shaft is supported by means of ball bearings, the mixing elementshave a screw connection. For operational safety a protective cage is fitted around the mixing element.S 50 N - W 80 SMK Jet mixer headFor shortening mixing and dissolving times. The vertical flow and the high tangential speed, up to 10000rpm, ensure intensive mixing. The head is used foradding gases or liquids, for lump-free suspension of difficult to dissolve powders or for dissolving sedimented, accreted substances.S 50 N - W 65 SK Cutting headTo crush large pieces (up to 50mm) of fibrous materials, such as plant matter, vegetables and fruit.

456

IKA

Type Max.immersion

depth

Workingvolume

PK Cat. No.

mm lR 50S 50 N - W 80 SMKS 50 N - W 65 SK

180350350

0.25 to 301 to 501 to 10

111

9.571 3509.570 9269.570 922

4

9.571 350

5

9.570 926

6

9.570 922

78

Type Volume range

Rotor dia.

PK Cat. No.

L mmR 1405 PropellerR 1402 Dissolver

0.25 to 301 to 30

4542

11

9.197 0539.197 055

7

9.197 053

8

9.197 055

Page 56: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

531

5. Sample preparationMixing, Homogenisation/Dispersers

GENERAL CATALOGUE EDITION 17

E & OE.

Homogenizer, Ultra-Turrax® T65 DHigh-performance dispersing instrument designed for typical college laboratory quantitiesof 2L to 50L (H2O).- powerful three-phase motor- three rotor/stator configurations available for diverse fields of application (not included with unit)- plug-in dispersing elements make changes simple- speed regulator available - details on request- dispersing heads for production applications available - details on request- supplied without cable and plug

1IKA

SpecificationsMotor rating, input/output: 1800/150WProcessing volume (H2O): 2L to 50LSuitable for viscosities up to: 5000mPasSpeed, fixed: 7200rpmSpeed stability: 5%Noise (without dispersing element): 75dB (A)Dimensions WxDxH: 190 x 580 x 380mmWeight: 28kgProtection class per DIN EN 60529: IP 54Supply requirements: 400V 50Hz 3ph.

230V 60Hz 3ph.Tested to DIN EN IEC 61010-1.

Type PK Cat. No.

T65D Ultra-Turrax® 1 9.570 505

1

Dispersion tools for Ultra-Turrax® T65DSterilisable by wet chemical method only.

234

IKAStator diameter: 65mmRotor diameter: 58mmMaterial: FFPM/SIC, AISI 316L

Type Workingvolume

Ult. finenesssuspensions / emulsions

Figure PK Cat. No.

l µmS 65 KG-HH-G 65 GS 65 KG-HH-G 65 MS 65 KG-HH-G 65 F

2 to 502 to 402 to 30

25 to 75 / 5 to 2520 to 50 / 5 to 155 to 20 / 1 to 10

abc

111

9.570 9339.570 9349.570 935

2

9.570 933

3

9.570 934

4

9.570 935

Stands and fittings for Dispersers T 10/T 18/T 25/T 50/T 65 D

5678

910

IKA

Type Description Roddia.

Height Formodel

PK Cat. No.

mm mmR 104H 44R 200R 1825RH 5R 1826R 1827R 182RH 3R 2722R 2723R 271T 653

StandBossheadClampStand with baseplateStrap clampStand with baseplateStand with baseplateBossheadStrap clampH-standTelescopic standBossheadTelescopic stand

10

16

1616

3434

48

370

560

8001000

1010620 - 1010

1200

T 10T 10T 10T 18 / T 25T 50T 18 / T 25T 18 / T 25T 18 / T 25T 18 / T 25T 50T 50T 50T 65 D

1111111111111

7.631 9719.232 9946.225 1589.224 0319.224 7629.224 0329.224 0339.224 2929.224 7619.224 0269.224 0289.224 2667.018 235

5

7.631 971

6

9.232 994

7

6.225 158

8

9.224 031

9

9.224 292

10

9.224 761

Page 57: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

532

5. Sample preparationMixing, Homogenisation/Ultrasonic homogenizers

GENERAL CATALOGUE EDITION 17

E & OE.

Ultrasonic Homogenizer SONOPULS mini20- pulse: ON cycles 0.1 to 60 secs.; OFF cycles 0.2 to 60 secs.- time modes, safety shut down: 59min, 59s- energy monitoring in kJ- remote control with PC: RS232 (infrared)- HF power: max. 20Weff

- processing frequency 30kHz- electrical supply data: 230 V~, 50/60 Hz

Ready-to-operate for volumes from 0.1 ml to 25ml, consisting of HF generator mini20, ultrasonic converter mini20 andmicrotip MS 2.5, diameter 2.5mm. Max. 12Weff HF output. Automatic amplitude control.

1Bandelin

HF generator GM mini20Dimensions: 250 x 256 x 154mmWeight: 2.0kgConverter UW mini20Dimensions, dia. x H: Approx. 50mm x 160mmWeight: 270gTitanium probes: 1.5mm and 2.5mm diameter

Type PK Cat. No.

SONOPULS mini20 1 9.650 160

1

Ultrasonic homogenizers, Sonopuls HD 2070/HD 2200For cell disruption, emulsification and homogenising of materials, liquid degassing,dispersion, extraction and for sonochemistry. Amplitude adjustable from 10 to 100%.Values can be monitored on the digital display. Pulsation time and data can be stored in the integrated memory.Processing frequency: 20 kHz, which is particularly effective. Fail-safe protection against operating when sample vesselempty and during continuous operation. For 230V 50/60Hz supplies, alternatively available for 115V~, 50/60Hz supplieson request. CE-marked, also as a medical device compliant to the in-vitro diagnostics directive 98/79/EG.

2Bandelin

On/off switch control: Possible directly at the converter, at the ultrasonic generator or via remote control (footswitch)

Amplitude adjustment: Electronically stabilised from 10 to 100%, ±1%Pulsation control: 10 to 100% permits heat dissipation when processing sensitive samplesTimer: 1 sec. to 99 mins. : 59 sec. or continuous operation

2

Ultrasonic homogenizer, SONOPULS HD 2070For volumes from 2ml to 50ml. Ready to operate, standard unit with GM2070 generator, UW 2070 ultrasonic converter, SH 70 G titanium stepped horn probewith external thread and MS 73 3 mm diameter micro tip. HF-output: max. 70 Weff. Titanium probes for other volumes(1ml to 200ml) are available with probes from 2mm to 13mm diameter.

3Bandelin

Type PK Cat. No.

SONOPULS HD 2070 1 9.650 180HD 2070 (stand and vessel are not included in delivery).

3

Ultrasonic homogenizer, SONOPULS HD 2200For volumes from 20ml to 900ml. Ready-to-operate standard unit with GM2200 generator, UW 2200 ultrasonic converter, SH 213 G booster horn with externalthread and diameter 13mm titanium tip TT 13. HF-output: max. 200 Weff. Titanium probes for other volumes (2ml to1000ml) are available with probes from diameter 2mm to 25mm.

4Bandelin

Type PK Cat. No.

SONOPULS HD 2200 1 9.650 185HD 2200 (stand and vessel are not included in delivery).

4

Page 58: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

533

5. Sample preparationMixing, Homogenisation/Ultrasonic homogenizers

GENERAL CATALOGUE EDITION 17

E & OE.

Ultrasonic homogenizers, SONOPULS HD 3100/ 3200/3400- Amplichron® control- amplitude setting adjustable in % or alternatively power control in W- Working frequency 20 kHz- Pulsation: operation intervals from 0.2 s up to 600 secs, rest intervals from 0.3 secs up to 600 secs- Timer 9 h: 59 min: 59 secs- Display of energy delivered to the sample in kJ- 9 user programmes- Probe monitoring (of specific probes)- Automatic amplitude limiting after preselection of the probe- Temperature indication from 0 up to 120°C (248°F), either with unit shutdown or alarm indication when the maximum temperature is exceeded, using

optional temperature sensor- WINPULS® remote control for process organisation with PC via RS232 and IR interfaces with IR adapter- Backlit graphics LCD readout- 230V~, 50/60Hz or 115V~, 50/60Hz

SONOPULS ultrasonic homogenizers are CE-marked, also as a medical device compliant to the in-vitro diagnostics directive 98/79/EG.

Applications: Disruption of highly-resistant bacteria, cells or tissues - Production of fine emulsions - Homogenization - Degassing of liquids - Samplepreparation for grain size analysis - catalysis of chemical reactions

Bandelin

HD 3100/HD 3200 (stand and vessel are not included in delivery)

Ultrasonic homogenizer, Sonopuls HD 3100High-Tech for research - using small volumes.For samples from 2 ml to 50ml, ready-to-operate standard setwith GM 3100 generator, UW 3100 ultrasonic converter , SH 70 G standard horn and MS 73 microtip, diameter 3 mm.

Max. 100W HF-output. - Processing frequency 20kHz. - for 230V 50/60Hz or 115V 50/60Hz supplies - For volumes from1 ml to 200ml - 5 titanium probes, 2mm to 13mm diameter, are available.

1Bandelin

HF generator GM 3100Dimensions: 250 x 256 x 170mmWeight: 2.0kgConverter UW 3100Dimensions: 70 x 120mm diameterWeight: 1kgTitanium probes*: 2mm, 3mm, 6mm, 13mm diameter

Type PK Cat. No.

SONOPULS HD 3100 1 9.650 170* on requestHD 3100 (stand and vessel are not included in delivery)

1

Ultrasonic homogenizer, SONOPULS HD 3200High-Tech for research - using larger volumesFor volumes from 20ml to 900ml, ready-to-operate standard set with generator GM2200, ultrasonic converter UW 2200, booster horn SH 213 G and flat titanium tip TT 13 diameter 13 mm.

Max. 200W HF-output. - Processing frequency 20kHz. - For 230V 50/60Hz or 115V 50/60Hz supplies - For volumes from2ml to 1000ml - 8 titanium probes available from 2mm to 25mm diameter.

2Bandelin

HF generator GM 3200Dimensions: 250mm x 256mm x 170mmWeight: 2.7kgConverter UW 3200Dimensions: 70 diameter x 120mmWeight: 1kgTitanium probes (diameter): 2mm, 3mm, 6mm, 13mm, 19mm, 25mm

Type PK Cat. No.

SONOPULS HD 3200 1 9.650 175* on requestHD 3200 (stand and vessel are not included)

2

Page 59: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

534

5. Sample preparationMixing, Homogenisation/Ultrasonic homogenizers

GENERAL CATALOGUE EDITION 17

E & OE.

Ultrasonic Homogenizer Sonopuls HD 3400High tech for research and pilot plant stationsReady-to-operate, basic unit for 100ml to 2500ml volumes consisting of generator GM3400, ultrasonic converter UW 3400, threaded booster horn SH 3425 G and probe VS 200 T, 25mm diameter VS 190, T19mm diameter on request. HF out put max. 400Weff.

1Bandelin

HF generator GM 3400Dimensions: 324 x 230 x 131mmWeight: 31kgConverter UW 3400Dimensions, dia. x H: 90 x 180mmWeight 2.2kgTitanium probes*: 19.25mm diameter

Type PK Cat. No.

SONOPULS HD 3400 1 9.650 195* on requestHD 3100/HD 3200 (stand and glas not included in delivery)

1

Booster horns and stepped horns for SONOPULS Ultrasonic homogenizers, titaniumalloyBooster horns, stepped horns (titanium alloy) for connection of interchangeablesonotrodes (probes). Further booster horns are available on request.

2345

Bandelin

Type Dia. For PK Cat. No.mm

Booster horn SH 213 GBooster horn SH 219 GBooster horn SH 225 GStepped horn SH 70 GBooster horn SH 3419Booster horn SH 3425

131925131925

HD 2200 / HD 3200HD 2200 / HD 3200HD 2200 / HD 3200HD 2070 / HD 3100HD 3400HD 3400

111111

9.650 2089.650 2189.650 2179.650 2059.650 2049.650 209

2

9.650 208

3

9.650 218

4

9.650 217

5

9.650 205

Ultrasonic homogenizers, SONOPULS, accessoriesStainless steel stands HG 5/10, with base plate.Clamping device KL 7 with rod, swivelling clamp and quick clamp for reaction vessels of15mm to 100mm diameter.Support table AT 7 suitable for KL 7 or in LS 8 and LS 10, for the safe stationing of ultrasonic irradiation vessels.

6

78

Bandelin

Type Description For PK Cat. No.

HG 5HG 10KL 7AT 7

Stainless steel standStainless steel standClamping deviceSupport table

HD 2070/ 3100 / 2200 / 3200HD 3400HG 5 / HG 10KL 7 or LS 8 / LS 10

1111

9.650 2739.650 2759.650 2769.650 277

6

9.650 273

7

9.650 276

8

9.650 277

Page 60: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

535

5. Sample preparationMixing, Homogenisation/Ultrasonic homogenizers

GENERAL CATALOGUE EDITION 17

E & OE.

Probes for Sonopuls Ultrasonic homogenizers, titaniumTitanium probes.For connection to stepped horns/booster horns.

1

2

3

Bandelin

Type Dia. Tip For Forbottle

For PK Cat. No.

mm mlMS 72

MS 73

KE 76

TT 13

TT 13 FZ

TT 19TT 25VS 70 T

VS 190 T

VS 200 T

MS 1.5MS 2.5

2.0

3.0

6.0

13.0

13.0

19.025.013.0

19.0

25.0

1.52.5

microtip

microtip

tapered tip

titanium flat tip

titanium flat tip with hole

titanium flat tiptitanium flat tipprobe long

probe long

probe long

microtipmicrotip

SH 70 GSH 213 GSH 70 GSH 213 GSH 70 GSH 213 GSH 70 GSH 213 GFZ 5 GFZ 7 GSH 219 GSH 225 GSH 70 GSH 213 GSH 219 GSH 3419SH 225 GSH 3425UW mini20UW mini20

1 - 252 - 302 - 505 - 905 - 10010 - 35010 - 20020 - 900-

25 - 90030 - 100010 - 20020 - 90025 - 900500 - 150030 - 1000500 - 25000,1 - 100,5 - 25

HD 2070 / 2200HD 3100 / 3200HD 2070 / 2200HD 3100 / 3200HD 2070 / 2200HD 3100 / 3200HD 2070 / 2200HD 3100 / 3200HD 2200 / 3200

HD 2200 / 3200HD 2200 / 3200HD 2070 / 2200HD 3100 / 3200HD 2200 / 3200HD 3400HD 2200 / 3200HD 3400Sonpuls mini20Sonpuls mini20

1

1

1

1

1

111

1

1

11

9.650 244

9.650 245

9.650 246

9.650 250

9.650 247

9.650 2489.650 2499.650 239

9.650 243

9.650 240

9.650 1659.650 166

1

9.650 245

2

9.650 246

3

9.650 239

Flow-through standard horn for Sonopuls Ultrasonic homogenizers

- Flow-through standard horn FZ 5 G with external screwthread and titanium flat tip TT13 FZ.

- Flow-through standard horn FZ 7 G with external screwthread and titanium flat tip TT 13 FZ.

4

Bandelin

Type For PK Cat. No.

FZ 5 GFZ 7 G

HD 2070 / HD 3100HD 2200 / HD 3200

11

9.650 2419.650 242

4

Flow-through cell for SONOPULS Ultrasonic homogenizers, stainless steel

Flow-through cell for continuous flow-through processing. Stainless steel, sealed,vibration-free reaction vessel with cooling jacket. For connection to SH 70 G or SH 213 Gwith TT 13. For HD 2070, HD 2200, HD 3100 and HD 3200 homogenisers. Flow rate up to 30 L/hr.

5

Bandelin

Type PK Cat. No.

DG 4 G (flow-through) 1 9.650 269

5

Ultrasonic processing vessels for SONOPULS Ultrasonic homogenizers, plastic

Ultrasonic processing vessels. Plastic. For indirect ultrasonic irradiation. If BB 2 G isordered, titanium flat tip TT 13 is required. BB 6 fits directly to UW 2200/UW 3200.Microtube holder EH6. Stainless steel. For simultaneous, contact-free ultrasonic irradiation of up to 6 samples using theultrasonic homogeniser HD 2200/HD 3200 and ultrasonic processing vessel BB 6.

6

Bandelin

Type For PK Cat. No.

BB 2 GBB 6EH 6

HD 2070 / HD 3100HD 2200 / HD 3200BB6

111

9.650 2539.650 2549.650 258

6

Page 61: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

536

5. Sample preparationMixing, Homogenisation/Ultrasonic homogenizers

GENERAL CATALOGUE EDITION 17

E & OE.

Sleeve adapters for Sonopuls Ultrasonic homogenizers, PTFE

PTFE sleeve adapters for mounting probes into standard ground joint vessels. For usewith HD 2070/2200/3100/3200 homogenisers- NA 29 G: for vessels with standard ground joint 29/32 and for SH 70/213 G horns- NA 45 G: for vessels with standard ground joint 45/40 and for SH 70/213/219/225 G horns

1

Bandelin

Type PK Cat. No.

NA 29 GNA 45 G

11

9.650 2289.650 229

1

Ultrasonic homogenizer cup booster BR 30 for SONOPULS HD 2070/ 2200/ 3100/ 3200

For Sonopuls HD 2070, HD 2200, HD 3100 and HD 3200.- BR 30 cup booster enables highly intensive sonication of small samples, e.g.radioactively-contaminated seeds, maceration of cells or sonification of pathogenic or toxic substances.

- EH 3: Microtube holder for BR 30 for simultaneous sonification of up to 3 samples.

23

Bandelin

SpecificationsBeaker capacity: 12mlInt. height: 15mmInt. diameter: 32mmMax. ultrasound intensity: 3100 W/L (HD 2200/3200)Material: Titanium alloy

Type PK Cat. No.

BR 30EH 3

11

9.650 1909.877 745

Converter and stand are not included.

2

9.650 190

3

9.877 745

Accessories for SONOPULS Ultrasonic homogenizers HD 2200, glass NEW!NEW!

Glass sample vessels for direct ultrasonic irradiation.

4

5

6

Bandelin

Type For probesup to Ø

Capacity For PK Cat. No.

mm mlKG 3 cooling vesselKG 5 cooling vesselDG 3 flow-through vesselwith cooling jacketDG 5 flow vesselwith cooling jacketRZ 1 rosett cellRZ 2 rosett cellRZ 3 rosett cellRZ 4 rosett cellRZ 5 rosett cellSZ 3 Suslick cellSZ 5 Suslick cell

132513

25

13131325251325

157015

70

2540

11039066020

110

HD 2070/2200/3100/3200HD 2200/3200HD 2070/2200/3100/3200

HD 2200/3200

HD 2070/2200/3100/3200HD 2070/2200/3100/3200HD 2070/2200/3100/3200HD 2200/3200/3400HD 2200/3200/3400HD 2070/2200/3100/3200HD 2200/3200

111

1

1111111

9.650 2359.650 2239.650 236

9.650 224

9.650 2679.650 2689.650 2619.650 2609.650 2649.650 2629.650 265

4

9.650 235

5

9.650 236

6

9.650 261

Page 62: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

537

5. Sample preparationMixing, Homogenisation/Ultrasonic homogenizers

GENERAL CATALOGUE EDITION 17

E & OE.

Sound proof boxes LS series NEW!NEW!

Provides considerable noise level reduction.

LS 4: Made of plastic-coated walls. 10dB(A) damping.LS 8/11: Made of stainless steel, with damping plates. 20dB(A) damping. With rod, swivelling clamp and bosshead forheight adjustment of sample vessels.

1Bandelin

Type For PK Cat. No.

LS 4LS 8LS 11

HD 2070 / 2200 / 3100 / 3200HD 2070 / 2200 / 3100 / 3200HD 3400

111

9.650 2719.650 2819.650 282

1

Accessories for sound proof box LS 8For sonification using the BR 30 cup booster, support frame UG 6 allows BB 6 or BB 2Gacoustic irradiation cups to rotate through 180° within the LS 8 noise protection box(not included with main instrument). Material: PTFE-coated, lacquered aluminium support with PTFE feet. Ultrasonicconverter UW 2070/2200/3100/3200 can be securely attached using the rapid snap fastener.

23

Bandelin

Description PK Cat. No.

Support UG 6 for LS 8Spacer AH 6 for LS 8*

11

9.650 2389.650 225

* Required for direct sonification using long probes.

2

9.650 238

3

9.650 225

Ultrasonic Processor UP50H/UP100HFor manual operation or for stand use, frequency 30kHz, automatic frequency tuningsystem, amplitude adjustable 20% to 100%, pulse 0 to 100%, dry running protected, inportable case, with mounting for stand STH-16 and mounting tools, 230V a.c.

56

4Hielscher Ultrasonics

Type Rating PK Cat. No.W

UP50HUP100H

50100

11

9.106 6006.235 231

5

9.106 600

6

6.235 231

4

Accessories for Ultrasonic Processor UP50H/UP100HSonotrode MS1, made of titanium, approx. length 80mmSonotrode MS3, made of titanium, approx. length 80mmSonotrode MS7, made of titanium, approx. length 80mmSonotrode MS10, made of titanium, approx. lenght 80mm (only for UP100H)

Stand ST1-16, pole diameter 16mm, made of stainless steel, base (L x W x H) 300 x 150 x 600mmSound Protection Box SB2-16, with adjustable table and 16mm stand poleTimer T1, from 00:00 to 99:59 (min:sec)

Hielscher Ultrasonics

Type Tip Forbottle

PK Cat. No.

mlMS1MS3MS7MS10ST1-16SB2-16T1

dia. 1mmdia. 3mmdia. 7mmdia. 10mm

0,1 - 5,05,0 - 10010,0 - 25020,0 - 500

1111111

9.106 6024.005 9899.106 6044.005 9906.226 5736.235 3306.235 003

Page 63: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

538

5. Sample preparationMixing, Homogenisation/Ultrasonic homogenizers

GENERAL CATALOGUE EDITION 17

E & OE.

Compact ultrasonic processor UP200SStand mounting, compact, robust unit, 200W, frequency 24kHz. With automaticfrequency scanning system, amplitude adjustable 20% to 100%, pulse adjustable 0 to100% and dry-running protected. Supplied in carrying case with mounting tools but without sonotrodes (probes). Awide range of accessories are available on request (sonotrodes, sound protection, PC control, etc.).

1Hielscher Ultrasonics

Type PK Cat. No.

UP200S 1 9.106 606

1

Sonotrode for compact ultrasonic processor UP200S2Hielscher Ultrasonics

Type Tip Forbottle

PK Cat. No.

mlS1S3S7S14S14D*

dia. 1mmdia. 3mmdia. 7mmdia. 14mm

0.1 to 5ml5 to 200ml20 to 500ml50 to 1000ml5 to 25L/h

11111

9.106 6079.106 6089.106 6099.106 6109.106 611

* with glass flow vessel GD14K.

2

Ultrasonic Processor UP200HFor manual operation or for stand use, 200W, frequency 24kHz, automatic frequencytuning system, amplitude adjustable 20% to 100%, pulse 0 to 100%, dry runningprotected, in portable case, with mounting tools, 230V a.c.

3Hielscher Ultrasonics

Type PK Cat. No.

UP200H 1 4.005 991

3

Accessories for Ultrasonic Processor UP200HSonotrode S3, titanium, approx. length 100mmSonotrode S7, titanium, approx. length 100mmSonotrode S14, titanium, approx. length 100mmSonotrode S40, titanium, approx. lenghth 100mm

Stand ST1-16, rod diameter 16mm, stainless steel, base (L x W x H) 300 x 150 x 600mmSound Protection Box SB3-16, with adjustable table and 16mm stand poleTimer T1, from 00:00 - 99:59 (min:sec)

4Hielscher Ultrasonics

Type Tip Forbottle

PK Cat. No.

mlS3S7S14S40ST1-16SB3-16T1

dia. 3mmdia. 7mmdia. 14mmdia. 40mm

5.0 - 20020 - 50050 - 1000100 - 2000

1111111

9.106 6089.106 6099.106 6104.005 9926.226 5736.227 8966.235 003

4

Page 64: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

539

5. Sample preparationMixing, Homogenisation/Ultrasonic homogenizers

GENERAL CATALOGUE EDITION 17

E & OE.

SonoStep SetUltrasonic processor, 100W, ultrasonic frequency 30kHz, microprocessor controlled,automatic frequency tuning system, amplitude adjustable from 20% to 100%,adjustable propeller output signal 20% to 100%, dry running protected, with 15-pin interface (0 to 10V), mountingtools, stainless-steel housing, IP65 grade, titanium resonator, thermocouple (AISI316Ti) with digital display, digitalpower-meter, O-Rings made of EPDM, detachable stainless steel rotor (AISI316Ti) for pumping and stirring, acrylicshield for noise reduction and spill protection, Dimensions (L x W x H): 280mm x 210mm x 350mm, 230V a.c.

1Hielscher Ultrasonics

Type PK Cat. No.

SonoStep SetTimer T2

11

4.006 0054.006 006

1

Ultrasonic Processor UIS250v for Eppendorf tubesFor handheld operation or for stand use, 250W. Ultrasonic frequency 24kHz, automaticfrequency tuning system, amplitude adjustable from 20% to 100%, pulse adjustablefrom 0 to 100%, dry running protected, transducer protected to IP40 level, 230V a.c.

2Hielscher Ultrasonics

Type PK Cat. No.

UIS250v 1 4.005 993

2

Accessories for Ultrasonic Processor UIS250vSonotrode LS24d3, titanium, approx. length 100mmSonotrode LS24d5, titanium, approx. length 100mmSonotrode LS24d10, titanium, approx. length 100mmSonotrode VT24d10, titanium, with 1 bore hole diameter 10mm for sonication of one vial (outer diameter 10mm)Sonotrode VialTweeter, titanium, with bores and clamping fixture for the sonication of up to 8 x 1.5ml Eppendorf tubes

Stand ST1-16clamp, rod diameter 16mm, made of stainless steel, base (L x W x H): 300 x 150 x 600mmTimer T1, from 00:00 to 99:59 (min:sec)

3 4Hielscher Ultrasonics

Type Tip Forbottle

PK Cat. No.

mlLS24d3LS24d5LS24d10VT24d10VialTweeterST1-16ClampT1

dia. 3mmdia. 5mmdia. 10mmdia. 10mm

5.0 - 20020 - 30050 - 1000

1111111

4.005 9944.005 9954.005 9964.005 9974.005 9984.005 9996.235 003

3

4

Ultrasonic Processor UIS250L for sieving250W, ultrasonic frequency 24kHz, automatic frequency tuning system, amplitudeadjustable from 20% to 100%, pulse adjustable from 0 to 100%, dry running protected,IP40 grade transducer , 230V a.c.

5Hielscher Ultrasonics

Type PK Cat. No.

UIS250L 1 4.006 001

5

Page 65: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

540

5. Sample preparationMixing, Homogenisation/Ultrasonic homogenizers

GENERAL CATALOGUE EDITION 17

E & OE.

Accessories for Ultrasonic Processor UIS250LRing sonotrode RIS200, H = 35mm, for the use of standard laboratory test sieves (DINISO 3310/1)Ring sonotrode RIS203, H = 35mm, for the use of standard laboratory test sieves (ASTM E 11-95)

Accessories set SZS200 for screens and ring sonotrode, Set: base plate, support rods with quick chuck, catch pan,cover clamping

1Hielscher Ultrasonics

Type Dia. PK Cat. No.mm

RIS 200RIS 203,5SZS 200

200203.5

200/203.5

111

4.006 0024.006 0034.006 004

1

Shaker, Disruptor Genie® NEW!NEW!

For cell disruption and homogenisation. The patented Disruptor Genie provides amulti-directional action, which simultaneously agitates and vortexes at high speed,dramatically increasing cell disruption or sample resuspension efficiency.

- Dramatically increased sample disruption efficiency. Ideal for difficult glass bead procedures (Glass beads - pleaseorder separately), cell disruption/homogenisation of yeast, bacteria, plant and animal tissues and pelletresuspensions or anything that requires extremely violent, high-speed agitation.

- Patented multi-directional action simultaneously agitates and vortexes at high-speed producing greater yields in lesstime

- Hands-Free disruption of up to twelve 1.5ml or 2.0ml microtubes with timer from 0 to 15 minutes or continuousoperation

- Performance comparable to expensive ultrasonic cell disruptors/homogenisers.- Suitable for use in cold rooms or incubators- Remove the microtube holder and attach the supplied pop-off cup for high-speed vortexing of single test tubes- Also available as digital version

Supplied with:- Disruptor Genie- Tube holder for 12 tubes- Universal Vortex attachement

2Si Scientific Industries

SpecificationsDimensions (WxDxH): 122 x 165 x 190mmWeight: 4.3kgSupply requirements: 220V 50Hz, 250mA

Description Connector PK Cat. No.

Disruptor Genie®, 2mlDisruptor Genie®, 2mlDisruptor Genie®, 1.5mlDisruptor Genie®, 1.5ml

EUUKEUUK

1111

9.730 0929.730 0939.730 0959.730 096

2

Accessories for Disruptor Genie® NEW!NEW!3

Description PK Cat. No.

1.5ml Snap-top Microtube Holder2ml Screw-cap Microtube Holder0.1mm Disruptor Beads, 375g0.5mm Disruptor Beads, 375g

1111

9.730 0989.730 0999.730 1009.730 101

3

Page 66: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

541

5. Sample preparationMixing, Homogenisation/Homogenisers

GENERAL CATALOGUE EDITION 17

E & OE.

Homogenisers, General Purpose- Clear or ground borosilicate glass mortars with a range from 5.0ml to 55ml capacity- Choice of borosilicate glass pestles with ground glass working length or serrated PTFEpestles

- Standard Stainless steel rod for use with an electric motor- Optional Stainless steel handle for manual grinding- All parts are fully autoclavable

Grinding clearance pestle and mortar for PTFE pestles is 0.076mm to 0.126mm and for glass pestles 0.152mm to0.254mm.

Order General Purpose range pestles and mortars separately. The pestle and mortars are listed separately,so you can choose either a glass or PTFE pestle for use with the same mortar.

1GPE Scientific Limited

1

Mortars

Capacity MortarL x o.d.

Glassbody

PK Cat. No.

ml mm510153055510153055

100 x 15115 x 17120 x 19150 x 23175 x 31100 x 15115 x 17120 x 19150 x 23175 x 31

clearclearclearclearcleargroundgroundgroundgroundground

1111111111

9.164 5209.164 5219.164 5229.164 5239.164 5249.164 5259.164 5269.164 5279.164 5289.164 529

Pestles

ForMortar

PestleL x o.d.

Material PK Cat. No.

ml mm510153055510153055

195 x 10215 x 13220 x 15250 x 19295 x 25250 x 10250 x 13250 x 15250 x 19250 x 25

borosilicate glassborosilicate glassborosilicate glassborosilicate glassborosilicate glassPTFE*PTFE*PTFE*PTFE*PTFE*

1111111111

9.164 5309.164 5319.164 5329.164 5339.164 5349.164 5359.164 5369.164 5379.164 5389.164 539

*with stainless steel rod

Handle for General Purpose homogenisersDescription PK Cat. No.

Stainless steel handle for pestles 1 9.164 515

Homogenisers, Safe-Seal, borosilicate glass/PTFE NEW!NEW!

Supplied complete with a PTFE pestle, stainless steel handle and borosilicate glass mortarwhich is stoppered in PTFE to protect against splash back during the grindingprocess.

2GPE Scientific Limited

Capacity PestleL x o.d.

MortarL x o.d.

PK Cat. No.

ml mm mm5101530

250 x 10250 x 13250 x 15250 x 19

140 x 15150 x 17155 x 19180 x 23

1111

9.164 5019.164 5029.164 5039.164 504

2

Page 67: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

542

5. Sample preparationMixing, Homogenisation/Homogenisers

GENERAL CATALOGUE EDITION 17

E & OE.

Potter-elvehjem homogenisers, plastic coated NEW!NEW!

Uniform plastic coated tissue grinders afford an added measure of safety. Fullyautoclavable. Stainless steel handle - please order separately.

1GPE Scientific Limited

Capacity PestleL x o.d.

MortarL x o.d.

PK Cat. No.

ml mm mm510153055

250 x 10250 x 13250 x 15250 x 19250 x 25

100 x 15115 x 17120 x 19150 x 23175 x 31

22222

9.164 5109.164 5119.164 5129.164 5139.164 514

1

Homogenisers, Handle for Potter-elvehjem NEW!NEW!

Handle for Potter-elvehjem homogenisers

Description PK Cat. No.

Stainless steel handle for pestles 1 9.164 515

Homogenisers, Mini series, borosilicate glass NEW!NEW!

Manufactured from high quality borosilicate glass this range of mini homogenisers isideal for micro tissue work. Bodies are clear precision glass. Pestles have ground glassworking length. With or without handles. Fully autoclavable.Grinding clearance pestle and mortar 0.152mm to 0.254mm.

2GPE Scientific Limited

Capacity PestleL x o.d.

MortarL x o.d.

Description PK Cat. No.

ml mm mm0.11.03.00.11.03.0

75 x 3.65150 x 5.00170 x 9.0075 x 3.65150 x 5.00170 x 9.00

60 x 9105 x 10115 x 1360 x 9105 x 10115 x 13

with handlewith handlewith handlewithout handlewithout handlewithout handle

111111

9.164 5419.164 5429.164 5439.164 5449.164 5459.164 546

2

Homogenisers, Griffiths Tube, Borosilicate glass 3.3, small NEW!NEW!

For grinding bacterial emulsions and tissues, tube 90mm to 95mm long, 18mm o.d.narrowing to ground rounded end. Ground half spherical pestle and mortar ends, ensureperfect grinding.

3

GPE Scientific Limited

Capacity PestleL x o.d.

MortarL x o.d.

PK Cat. No.

ml mm mm5 150 x 12 95 x 18 1 9.164 550

3

Homogenisers, Griffiths Tube, Borosilicate glass 3.3, large NEW!NEW!

Ground pestle and mortar, pestle has projections for coarse grinding.Mortar length 220mm.

4

GPE Scientific Limited

Capacity PestleL x o.d.

MortarL x o.d.

PK Cat. No.

ml mm mm15 305 x 14 225 x 18 1 9.164 551

4

Page 68: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

543

5. Sample preparationMixing, Homogenisation/Homogenisers

GENERAL CATALOGUE EDITION 17

E & OE.

Homogenisers, Round Body, glass NEW!NEW!

The all-glass Uni-Form range of round body tissue grinders is made from sterilisableheat-resisting glass in capacities 5ml to 55ml. Models are available with rod ends formotor drive, or hollow pestles designed for use with coolants/dry ice. Bodies are available in clear precision glass orground glass for more effective homogenisation of tougher tissues.Grinding clearance pestle and mortar 0.152mm to 0.254mm.

1GPE Scientific Limited

1

Capacity PestleL x o.d.

MortarL x o.d.

Mortar Pestle PK Cat. No.

ml mm mm510153055510153055510153055510153055

205 x 10225 x 13240 x 15295 x 19330 x 25205 x 10225 x 13240 x 15295 x 19330 x 25205 x 10225 x 13240 x 15295 x 19330 x 25205 x 10225 x 13240 x 15295 x 19330 x 25

105 x 15130 x 17140 x 19170 x 23205 x 31105 x 15130 x 17140 x 19170 x 23205 x 31105 x 15130 x 17140 x 19170 x 23205 x 31105 x 15130 x 17140 x 19170 x 23205 x 31

clear glassclear glassclear glassclear glassclear glassclear glassclear glassclear glassclear glassclear glassground glassground glassground glassground glassground glassground glassground glassground glassground glassground glass

hollowhollowhollowhollowhollowwith rod endwith rod endwith rod endwith rod endwith rod endhollowhollowhollowhollowhollowwith rod endwith rod endwith rod endwith rod endwith rod end

11111111111111111111

9.164 6609.164 6619.164 6629.164 6639.164 6649.164 6659.164 6669.164 6679.164 6689.164 6699.164 6709.164 6719.164 6729.164 6739.164 6749.164 6759.164 6769.164 6779.164 6789.164 679

For our Life Science produkt range - please see page 1165

Homogenisers, Dounce, glass NEW!NEW!

For fine particle size reductions without damage to cell nuclei. Supplied withinterchangeable pestles ground and polished to large and small clearances for use in thesame tube. Includes 2 larges pestle used for sample preparation and 2 tight pestles for final homogenate.

2GPE Scientific Limited

Capacity PestleL x o.d.

MortarL x o.d.

PK Cat. No.

ml mm mm171540

117 x 7.5175 x 13210 x 15285 x 25

82 x 12125 x 17160 x 19210 x 31

1111

9.164 6909.164 6919.164 6929.164 693

2

Homogenisers, Duo-Form, Borosilicate glass 3.3 NEW!NEW!

The pestles are conicaly shaped at the tip and cylindrically shaped in the upper part. Thiscombination gives two separate areas, one for initial grinding and a second for finalhomogenisation.

3GPE Scientific Limited

Capacity PestleL x o.d.

MortarL x o.d.

Mortar Pestle PK Cat. No.

ml mm mm15151515

250 x 15250 x 15250 x 15250 x 15

155 x 19155 x 19155 x 19155 x 19

groundclear glassgroundclear glass

with rodwith rodwith handlewith handle

1111

9.164 6809.164 6819.164 6829.164 683

3

Page 69: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

544

5. Sample preparationMixing, Homogenisation/Homogenisers

GENERAL CATALOGUE EDITION 17

E & OE.

Duall homogenisers, with glass pestleWith conical and cylindrical area for effective tissue for grinding and also for homogenising. Especially suitable forcellular tissue such as muscle, heart and lungs. The pestle is sufficiently stable to be motor driven. The space betweenthe pestle and mortar is between 0.1mm to 0.15mm. Spare components are available and are completelyinterchangeable.

1

Size Capacity PestleL x o.d.

MortarL x o.d.

PK Cat. No.

ml mm mm202122232425

135

153050

155 x 6207 x 6220 x 8278 x 10310 x 10345 x 16

80 x 13120 x 16150 x 18175 x 25215 x 32225 x 38

111111

9.651 6379.651 6389.651 6399.651 6419.651 6429.651 643

1

Duall homogenisers, with PTFE pestleWith conical and cylindrical area for effective tissue for homogenising. The PTFE pestle is ideal for soft tissue such asbrain or liver. The pestle is suitable for motor drive. The space between the pestle and mortar is between 0.1mm to0.15mm. Spare components are available and are completely interchangeable.

2

Size Capacity MortarL x o.d.

PestleL x o.d.

PK Cat. No.

ml mm mm202122232425

135

153050

155 x 4.5210 x 6228 x 6268 x 6305 x 10330 x 10

80 x 13120 x 16150 x 18175 x 25215 x 32225 x 38

111111

9.651 6569.651 6579.651 6589.651 6599.651 6609.651 661

2

Potter-elvehjem homogenisers, with glass pestleAll-glass. Pestle is suitable for motor drive. The space between the pestle and mortar is between 0.1mm to 0.15mm.Spare components are available and are completely interchangeable.

3

Size Capacity PestleL x o.d.

MortarL x o.d.

PK Cat. No.

ml mm mm1921222324

158

1745

145 x 5205 x 6215 x 8265 x 10315 x 10

95 x 13140 x 16150 x 18175 x 25220 x 32

11111

9.651 6749.651 6759.651 6769.651 6779.651 678

3

Potter-elvehjem homogenisers, with PTFE pestleWith PTFE pestle and glass mortar. Sizes 21 and 24 have notches on the bottom edge of the pestle so that particles canbe transported up to the cylindrical part of the mortar for extraction. The space between the pestle and mortar isbetween 0.1mm to 0.15mm. Spare components are available and are completely interchangeable.

4

Size Capacity PestleL x o.d.

MortarL x o.d.

PK Cat. No.

ml mm mm18192021222324

0.513581745

130 x 3154 x 5154 x 5215 x 6212 x 6266 x 6269 x 6

80 x 1295 x 12115 x 12140 x 15150 x 19175 x 25220 x 32

1111111

9.651 6899.651 6909.651 6919.651 6929.651 6939.651 6949.651 695

4

Page 70: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

545

5. Sample preparationMixing, Homogenisation/Homogenisers

GENERAL CATALOGUE EDITION 17

E & OE.

Homogenisers with PTFE pestlesGlass homogeniser mortar with conical or cylindrical PTFE pestles mounted on corrosion-resistant, stainless steel shafts. Inert.Resilient. With smooth, wax-like, moisture-repellent surface. Glass-fibre reinforced pestles are available for grinding particularlytough materials.For all common homogeniser drives or for schuett homgenplus.

1 2 3schuett-biotec

Glass mortar Type 1: With flared overflow neck and spout, conical (Fig. A)Glass mortar Type 2: Without flared overflow neck, cylindrical (Fig. B)Glass mortar Type 3: With flared overflow neck and spout, cylindrical (Fig. C)

Glassmortartype

Capacity Form PK Cat. No.

ml111222322322323

2154025

10152030405

10153040

PTFE pestle taperedPTFE pestle taperedPTFE pestle taperedPTFE pestle cylindricalPTFE pestle cylindricalPTFE pestle cylindricalPTFE pestle cylindricalPTFE pestle cylindricalPTFE pestle cylindricalPTFE pestle cylindricalPTFE pestle cylindrical, glass-fibre reinforcedPTFE pestle cylindrical, glass-fibre reinforcedPTFE pestle cylindrical, glass-fibre reinforcedPTFE pestle cylindrical, glass-fibre reinforcedPTFE pestle cylindrical, glass-fibre reinforced

111111111111111

9.651 8509.651 8519.651 8529.651 8539.651 8549.651 8559.651 8569.651 8579.651 8589.651 8599.651 8609.651 8619.651 8629.651 8639.651 864

1 2 3

Homogenisers with glass pestlesGlass homogeniser mortar with glass pestle.With robust glass shaft and ground surface cylindrical or conical pestle heads. Highlyefficient for use with tough tissues. For all common homogeniser drives or for schuett homgenplus.

4 5 6schuett-biotec

Glass mortar Type 4: With flared overflow neck and spout, conical (Fig. A)Glass mortar Type 5: Round bottom, with flared overflow neck, without spout, cylindrical (Fig. B)Glass mortar Type 6: Round bottom, with flared overflow neck, with spout, cylindrical (Fig. C)

Glassmortartype

Capacity Form PK Cat. No.

ml444556

215408

1540

Glass pestle, taperedGlass pestle, taperedGlass pestle, taperedGlass pestle, cylindricalGlass pestle, cylindricalGlass pestle, cylindrical

111111

9.651 8659.651 8669.651 8679.651 8689.651 8699.651 870

4 5 6

Page 71: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

546

5. Sample preparationMixing, Homogenisation/Homogenisers

GENERAL CATALOGUE EDITION 17

E & OE.

EPPI pestle for tubes (Pellet)For homogenising in Eppendorf®-type 1.5ml/2.0ml reaction tubes (exact fit).

EPPI pestle, conical, stainless steel:Crevice-free, no cross-contamination, easy to clean and autoclaveable. Suitable for operation with liquid nitrogen.EPPI pestle, conical, PP and quick-change chuck (please order separately):For easy exchange of pestles without stopping the motor when using a semi-automatic. Increases the productivity, nocross contamination with serial samples

For all common homogeniser drives or for schuett homgenplus.

12

schuett-biotec

Type Shaftdiameter

Length PK Cat. No.

mmStainless steel EPPI pestlePolypropylene EPPI pestleQuick-change chuck, stainless steel

dia. 4.9mmdia. 4.9mm

10070

1101

9.197 6909.197 6899.197 691

1

9.197 690

2

9.197 689

Homogeniser drive unit, schütt homgenplus

For the gentle homogenisation of biological samples or for grinding tough, rigid materialwhich is difficult to break down. Complete with load-compensating drive unit anduniversal quick-action chuck, transparent Plexiglas cooling jacket and multi-purpose spanner for centring homogenisingvessels of varying sizes. Portable, but highly stable and vibration-free due to its triple-post frame construction, and easyto use. Provides high torque, even at the low speed range, ensuring extremely powerful homogenizing. Continuouslyadjustable speed range: 40rpm to 3000rpm. Provides reproducible homogenising by maintaining constant rotationalspeed, which is shown on an easy to read, 4-digit LED display. The fast-action clamping chuck with hollow shaft permitsrapid and easy replacement of the pestle and allows pestles with longer shafts to be used. We highly recommend usinga quick-grip chuck for glass pestles to minimise lateral movement (and therefore strain) of the glass shaft. The coolingjacket incorporates a clamping holder suitable for Eppendorf test tubes and homogenising vessels with outsidediameters from 10mm to 40mm. Sample cooling is easily achieved using ice, which can be introduced into the coolingjacket through a screw capped opening. The homogenising vessel moves up and down in conjunction with the coolingjacket platform and is raised and lowered using a lever jack. The long lever facilitates thorough homogenising withoutmuch effort.For 230V 50/60Hz, 300 W single phase supplies (optionally available for 115V 50/60Hz).

We also offer a sterile alternative for use in a glove box and with infectious material. Details on request.

3schuett-biotec

Type External dimensions(W x D x H)

PK Cat. No.

mmschuett homgenplus, 230 VQuick-change chuck for glass pestle

300 x 350 x 888-

11

9.651 5609.651 564

3

We can supply this

manufactorer’swhole

product range !

Page 72: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

547

5. Sample preparationMixing, Homogenisation/Homogenisers

GENERAL CATALOGUE EDITION 17

E & OE.

LLG-Micropestles, stainless steel NEW!NEW!Polished stainless steel, micropestles. Precise fitting, manufactured in one-piece, smooth handle sections, can be disinfected easily. Minimum homogenatedisplacement due to tapered piston.

For Reaction tubes:For homogenisation of cells, tissues or foodstuffs/feed samples.- For tubes with 0.5ml, 1.5ml and 2.0ml- Can be cooled down to -196°C- Sterilisable in an autoclave or dry heat at +200°C- Suitable for PCR applications- Alternative to single-use plastic pestles

For Sarstedt tubes:Primarily used with food analysis with light and highly processed samples.- For tubes 13ml

1234

Forbottle

Length PK Cat. No.

ml mm0.51.52.013.0

94124120190

1111

9.314 5009.314 5019.314 5029.314 503

1

9.314 500

2

9.314 501

3

9.314 502

4

9.314 503

Disposable micro pestles, PPAutoclavable polypropylene. Suitable for battery-operated drive motor (9.314 496). Pestle length 7cm. Supplied withmicrocentrifuge tubes as outlined below.

5

Description PK Cat. No.

Pestle for 0.5ml withmicrocentrifuge tubesPestle for 1.5ml withmicrocentrifuge tubes0.5ml pestlePestle for 0.5ml withmicrocentrifuge tubes*Pestle for 1.5ml withmicrocentrifuge tubes*

100

100

100100

100

9.314 490

9.314 491

9.314 4929.314 498

9.314 499

*RNase, DNase and pyrogen free

5

Micro pestles, PTFE, with stainless steel shaftPTFE. With stainless steel shaft. For 1.5ml microcentrifuge tubes.Overall length 143mm.

6

Type PK Cat. No.

FlatRound

11

9.315 0009.315 001

6

Page 73: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

548

5. Sample preparationMixing, Homogenisation/Homogenisers

GENERAL CATALOGUE EDITION 17

E & OE.

Micro pestles, CTFE/stainless steelReusable, for 500µl and 1.5ml microcentrifuge tubes. Autoclavable CTFE/stainless steel. Suitable for battery-operateddrive motor (9.314 496).

1

Capacity Length* PK Cat. No.ml0.51.5

614

11

9.314 4949.314 495

* Pestle length (cm)

1

Micro pestles, accessory drive motor2

Type PK Cat. No.

Complete with two batteriesSpare pestle adapter

11

9.314 4969.314 497

2

BAGMIXER® Starter Pack NEW!NEW!

The starter pack has everything to start a microbiological analysis.

Supplied with: 1 BagMixer® 400 VW, 500 BagFilter®, 1000 BagLight®, 50 BagClip®, 1 BagOpen® and 1 BagRack®.

3interscience

Type PK Cat. No.

BAGMIXER® Starter Pack 1 9.570 015

3

Laboratory paddle blender BagMixer® 100 MiniMix® NEW!NEW!

MiniMix® 100 paddle blenders, from the BagMixer® range, guarantees a quick and accurate blending of small samples. Thanks tothe adjustable paddle system, blending is at its best. MiniMix® 100 is ideal for medical, veterinary and microbiological analysis.

45

interscience

Type Capacity PK Cat. No.ml

MiniMix® 100 P CC®

MiniMix® 100 W CC®

80-10080-100

11

6.240 5096.241 090

4

6.240 509

5

6.241 090

Page 74: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

These highly resistant bags provide increased safety. The filter bags automatically filter the sample during the blending process,withholding particles behind the filter.

The BagPage® has a full-width membrane filter.

The BagFilter® P is a non-woven lateral filter and it is sterile.

549

5. Sample preparationMixing, Homogenisation/Homogenisers

GENERAL CATALOGUE EDITION 17

E & OE.

Laboratory mixer, BagMixer®

For sample preparation with easily adjustable paddle system. The BagMixer® is availablein 3 sizes and blends all sample types prior to their microbial analysis. Thanks to theirunique adjustable paddle system the blending chamber can be adjusted to the sample volume. Combined with thevariable speed, a higher bacterial recovery rate is achieved. All BagMixer® units are fitted with a timer. Constructed instainless steel. The fully opening door enables easy cleaning.

Click & clean® System (only BagMixer® 400 CC): removable and autoclavable paddles.

All units have a 3-year warranty and life guarantee for shock absorbers and window door.

1interscience

Type Capacity Length Width Height PK Cat. No.ml mm mm mm

BagMixer® 400 VWBagMixer® 400 CCJumboMix® 3500 VW

50 to 40050 to 300400 to 3500

390400420

270220540

260240500

111

9.570 0739.570 0989.570 074

Scan 500 colony counter available on request!

1

Blender bags, BagSystem®2 3interscience

Type Description Width Height PK Cat. No.mm mm

BagLight® 100BagLight® 400BagLight® 3500BagFilter® 400 PBagFilter® 3500 PBagPage® 100BagPage® Plus 400BagPage® 3500

plain bag, sleeve 25plain bag, sleeve 25plain bag, sleeve 25side filter bag, sleeve 25side filter bag, sleeve 10full-size filter bag, sleeve 25full-size filter bag, sleeve 25full-size filter bag, sleeve 10

110175380190380180190380

18530051030051095

300510

5001000500500100500500100

9.570 0759.570 0979.570 0779.570 0789.570 0799.570 0809.570 0819.570 082

2 3

Page 75: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

550

5. Sample preparationMixing, Homogenisation/Homogenisers

GENERAL CATALOGUE EDITION 17

E & OE.

Accessories for blender BagSystem®1interscience

1

Type Description PK Cat. No.

BagOpen® 80/100BagOpen® 400BagOpen® 3500BagRack® 80/100BagRack® 400BagClip® 80/100BagClip® 400BagClip® 3500BagPipet®

BagTips® RegularBagTips® Jumbo

bag openerbag openerbag openerbag storage for 11 bagsbag storage for 10 bagsbag closure clipbag closure clipbag closure clippipette with 3 fixed graduations: 0.1, 0.9, 1.0mlstraws for BagPipet®, 19cm, sterilestraws for BagPipet®, 24cm, sterile

11111

5050501

10001000

9.570 0839.570 0849.570 0859.570 0869.570 0879.570 0889.570 0899.570 0909.570 0919.570 0929.570 093

Adhesive Labels - please see page 139

Sample bags, RollBag®

Sterile bags with seal reinforced with metal wire for BagMixer® lab blender and forcollecting samples in the food, dairy, water, sewage, medical, veterinary, environmental,soil and industrial fields. By whirling, the RollBag® becomes a leakproof bag. RollBag® is also thick and robust in order toresist bursting when handling a variety of samples.

2interscience

SpecificationsCapacity: 450mlBlended volume: 5 to 50mlCapacity: 1300mlBlended volume: 50 to 300ml

Capacity Dimensions(D x W)

PK Cat. No.

ml mm4501300

110175

xx

230290

1000500

9.570 0999.570 096

2

Gravimetric solvent diluter Gravimat®

The Gravimat® automatically dilutes a solid sample with the appropriate mass of solvent.Stainless steel. Complete traceability, LIMS connection.

Comprises:- Unit with 2 autoclavable dispenser tubes- 5L autoclavable bottle- BagOpen® sample bag holder

Accessories: Barcode reader, printer, booster kit (adds a double pump assembly and tubing to the unit, allowing liquidto be dispensed at a higher flow rate).

3interscience

SpecificationsBalance: 0.05 to 2500gAccuracy: >99%Dimensions (W x L x H): 250 x 420 x 300mmLanguages: F, UK, D, E, IT, JAP, CHIN

Type PK Cat. No.

Gravimat®, single pumpGravimat®, double pump

11

9.570 0949.570 095

3

Page 76: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

551

5. Sample preparationMixing, Homogenisation/Homogenisers

GENERAL CATALOGUE EDITION 17

E & OE.

Gravimetric solvent diluter, BabyGravimat®, 1 or 2 pumpsAll the Gravimat® technology in an all inox smaller unit: only 25cm wide. Ideal forsample dilution in a laminar-flow cabinet.

Available with single or dual pump.- Fast and accurate- Compact and extra user-friendly- RS232 output for LIMS or printer

Supplied with:an inox dispensing arm, 1 or 2 pumps, BagOpen® 400, 2 dispensing assemblies per pump, one pack of each BagFilter®P400, BagPage® Plus filter bags.

12

interscience

SpecificationsRange: from 0.1 g to 1000gDilution Precision: >99%Dimensions (W x L x H): 250 x 350 x 160mmWeight: 8kg

Type PK Cat. No.

BabyGravimat® single pumpBabyGravimat® double pump

11

9.570 0009.570 001

1

9.570 000

2

9.570 001

Page 77: 5. Sample preparation. Sample preparation Contents ... Mixing, Homogenisation 522 ... Operation: Insert Tubus into a sack to the desired sampling depth,

2011_LLG-ITT_Image-WTW.indd 1 20.07.2011 12:01:58