Boiler Efficiency Evaluation Efficiency Facts
• Combustion Efficiency (Burner)
• Heat Transfer Efficiency (Surface area)
• Boiler Efficiency (Total System Efficiency)
Boiler Efficiency
Shell Losses 2%
AshUnburnts 2%
Boiler Efficiency=75%Fuel 100%
Stea
m 7
5%
Flue
Gas
es 1
8%Blow Down 3%
Efficiency Evaluation Method
Direct Method• Measurement of
steam & Fuel flow only
• Approximate Result
Indirect Method• Measurement of
Temp, Pr, Fuel/Flue gas analysis,
• More accurate result
• Heat Loss Method• ASME/IS
DIRECT METHOD
Boiler Efficiency = Output X 100 Input
= (Steam Flow) X (Steam Enthapy- F W Enthalpy) ------------------------------------------------------------------
(Fuel Flow X GCV) OR
Boiler Efficiency =Evap.Ratio X Steam Enthalpy
GCV
INDIRECT METHOD(As per IS: 8753)
Various Boiler LossesVarious Boiler Losses
1.1. Heat Loss in Dry Flue GasesHeat Loss in Dry Flue Gases2.2. Heat Loss Due to Moisture and Hydrogen in the Heat Loss Due to Moisture and Hydrogen in the
Fuel Fuel 3.3. Heat Loss Due to Moisture in the AirHeat Loss Due to Moisture in the Air4.4. Heat Loss Due to Carbonmonoxide in Flue GasesHeat Loss Due to Carbonmonoxide in Flue Gases5.5. Surface Heat Loss Due to RadiationSurface Heat Loss Due to Radiation6.6. Blowdown LossesBlowdown Losses
CONTROLLABLE & UNCONTROLLABLE LOSSES
Boundary barrier Balance
Fueltank
Boiler400kg/hr30.c
30.c
APH
5200kg/hr,120 .c
320.c
stackSteamprocess
water520 kg.hr
179.c
4680kg/hr
10% makeup water
Measurements required for thermal energy Audit in Boiler
Fuel flow, steam/water flow
Temp & Pressure of steam
Temperature of water inlet / outlet of economizer
Draught
CO2, O2, CO , Temperature from Flue Gas
Surface Temp & Ambient Temp
Surface Area, m2
Size & dimension of boiler
Test Procedure • Plan / inform the concerned dept.
• All the Instrument should be calibrated • Ensure fuel and water availability• Test at maximum steam load condition• Conduct 8 hrs minimum (1/2 or 1 hr frequently)• Water level in drum should be same at start &
end of test• Gas Sampling point should be proper• No blow down during test
Requirements in boiler
• Oil level in tank• Water level in Service Tank • No leakage water• No blow down• Boiler Testing Sheet• Fuel Analysis Report• Boiler Technical Specifications
Fyrite kit
CO2, O2 in flue gases
Combustion analysers
Contact thermometer
Infrared thermometer
RPM measurement
Tachometer Stroboscope
Date : 8/2/2001Time Fuel ID PA SA ID PA SA O2 CO CO2 Temp Temp
Feederrpm KW
11:00 21 100% 40% 50% 22 8 1.9 14.2 307 5.1 125 29AM
11.30 30 50% 20% 30% 20.6 6.96 1.9 9.8 16 8.3 126 30AM
* At normal operatiing condition, power and flue gas measurement were taken Then, excess air reduced by closing damper in all FD and ID secondary air fan Fuel feeding rate is increased from 21 rpm to 30 rpm Again power and flue gas measurement were taken
Suggesions : 1) Keep furnace draft + 5mm 2) Flue gas should be light gray at chimny top
3) keep Lowest possible damper position
opening)(Power management) (Flue gas analysis)
BOILER PERFORMANCE TESTING
Steam Pressure - 5 to 7 kg/cm2
(Damper position
Boiler Calculations