14
Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12 J 460 460 Lightning Surge Protectors for Electronics Equipment M-RESTER Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Limit Alarms Gateway, Remote I/O Paperless Recording System PC Recorder Electric Actuators & Position Sensors Lightning Surge Protectors Lightning Surge Protectors M-RESTER Standard Signal Line & Pulse Use Lightning Surge Protectors Sensor Use Transmission Line Use Power Supply Use DC Power Supply Use One-port Surge Protector Accessories M-System Lightning Surge Protectors absorb only the lightning surges with no interruption of the instrumentation signal. Protects sensor, signal and power lines Can be removed and tested without disconnecting wires (MDP series) Superior protection and selection across a wide range of applications including: Frequency generating devices Telemetering devices RS-485 / RS-422, Ethernet, DeviceNet, PROFIBUS, LONWORKS, FOUNDATION Fieldbus AC/DC Power supply lines (1 amp up to 30 amps) 4–20mA & pulse signal Thermocouple RTD Potentiometer Strain gauge Standard Signal Line & Pulse Use Model Function Page MD7AST Lightning Surge Protector for Standard Signal Line (ultra-slim; life monitor) P.462 MDPA-24 Lightning Surge Protector for Standard Signal Line & Pulse Use (life monitor) P.462 MDPA-65 Lightning Surge Protector for Standard Signal Line & Pulse Use (life monitor) P.462 MDM2A-24 Lightning Surge Protector for Standard Signal Line & Pulse Use (life monitor) P.462 MDM2A-65 Lightning Surge Protector for Standard Signal Line & Pulse Use (life monitor) P.462 MD7ST Lightning Surge Protector for Standard Signal Line (ultra-slim) P.462 MDP-24-1 Lightning Surge Protector for Standard Signal Line & Pulse Use P.462 MDP-65-1 Lightning Surge Protector for Standard Signal Line & Pulse Use P.462 MDK-24 Lightning Surge Protector for Standard Signal Line Use P.463 MDJST Lightning Surge Protector for Standard Signal Use (fast response: 3 nsec.) P.463 MMDH Lightning Surge Protector for Standard Signal Line Use (high speed/high discharge current capacity) P.463 MMD Lightning Surge Protector for Standard Signal Line Use (high discharge current capacity) *** MD72W Lightning Surge Protector for Two-wire Signal Loop (ultra-slim) P.463 MD72WD Lightning Surge Protector for Two-wire Signal Loop (ultra-slim; 2 channels) P.463 MD73W Lightning Surge Protector for Three-wire Signal Loop (ultra-slim) P.463 MD6N-24 Lightning Surge Protector for Standard Signal Line & Pulse Use (conduit mount, weather-proof) P.464 MD6N-65 Lightning Surge Protector for Standard Signal Line & Pulse Use (conduit mount, weather-proof) P.464 MD6T-24 Lightning Surge Protector for Standard Signal Line & Pulse Use (conduit mount, weather-proof) P.464 MD6T-65 Lightning Surge Protector for Standard Signal Line & Pulse Use (conduit mount, weather-proof) P.464 MD6P-24 Lightning Surge Protector for Standard Signal Line & Pulse Use (conduit mount, weather-proof) P.464 MD6P-65 Lightning Surge Protector for Standard Signal Line & Pulse Use (conduit mount, weather-proof) P.464 Sensor Use Model Function Page MD7TC Lightning Surge Protector for Thermocouple (ultra-slim) P.465 MDP-TC Lightning Surge Protector for Thermocouple Use P.465 MD7RB Lightning Surge Protector for RTD (ultra-slim) P.465 MDP-RB Lightning Surge Protector for RTD Use P.465 MD7PM Lightning Surge Protector for Potentiometer (ultra-slim) P.465 MDP-PM Lightning Surge Protector for Potentiometer Use P.465 MD7LC Lightning Surge Protector for Strain Gauge Use (ultra-slim) P.466 MDP-LC Lightning Surge Protector for Strain Gauge Use P.466 MDK-LC Lightning Surge Protector for Strain gauge Use P.466 MD-LC2 Lightning Surge Protector for Strain gauge Use (6-wire remote sensing) P.466 MDK-LV Lightning Surge Protector for Signal Line with Excitation Use P.466 MD7JS Lightning Surge Protector for Self-Synch Use (ultra-slim) P.467 MDP-JS Lightning Surge Protector for Self-Synch Use P.467 MD7PL Lightning Surge Protector for Pulse Signal (ultra-slim) P.467 MDP-SP Lightning Surge Protector for Low Frequency Use P.467 MDR2 Lightning Surge Protector for Multi-channel Use (high discharge current capacity) P.467 Transmission Line Use Model Function Page MD74R Lightning Surge Protector for RS-485/RS-422 (ultra-slim) P.468 MDP-4R Lightning Surge Protector for RS-485/RS-422 P.468 MDW5-4R Lightning Surge Protector for RS-485/RS-422 (full-duplex) P.468 MDW2A-4R Lightning Surge Protector for RS-485/RS-422 (life monitor) P.468 MDCAT Lightning Surge Protector for Ethernet (PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T) P.468 MDM5E-A Lightning Surge Protector for Ethernet (100 BASE-TX / 10 BASE-T) P.468 SHSP 8-Port Ethernet Switch (with surge protector) P.469

460 TL,MD7AP,MDP-100,MDP-200,MA-100,MA-200,MAA ...Data sheets available on Web in PDF. Visit M-System Data Library at ISP ’12 J 460 460 Lightning Surge Protectors for Electronics

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 460 TL,MD7AP,MDP-100,MDP-200,MA-100,MA-200,MAA ...Data sheets available on Web in PDF. Visit M-System Data Library at ISP ’12 J 460 460 Lightning Surge Protectors for Electronics

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12

J

460

460 Lightning Surge Protectors for Electronics Equipment

M-RESTERSignal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Lightning Surge ProtectorsM-RESTER

Standard Signal Line & Pulse Use

Lightning Surge Protectors

Sensor Use

Transmission Line Use

Power Supply Use

DC Power Supply UseOne-port Surge Protector

Accessories

M-System Lightning Surge Protectors absorb only the lightning surges with no interruption of the instrumentation signal.

◆ Protects sensor, signal and power lines

◆ Can be removed and tested without disconnecting wires (MDP series)

◆ Superior protection and selection across a wide range of applications including:

Frequency generating devicesTelemetering devicesRS-485 / RS-422, Ethernet, DeviceNet, PROFIBUS, LONWORKS, FOUNDATION FieldbusAC/DC Power supply lines (1 amp up to 30 amps)

4–20mA & pulse signalThermocoupleRTDPotentiometerStrain gauge

■ Standard Signal Line & Pulse Use

Model Function Page

MD7AST Lightning Surge Protector for Standard Signal Line (ultra-slim; life monitor) P.462

MDPA-24 Lightning Surge Protector for Standard Signal Line & Pulse Use (life monitor) P.462

MDPA-65 Lightning Surge Protector for Standard Signal Line & Pulse Use (life monitor) P.462

MDM2A-24 Lightning Surge Protector for Standard Signal Line & Pulse Use (life monitor) P.462

MDM2A-65 Lightning Surge Protector for Standard Signal Line & Pulse Use (life monitor) P.462

MD7ST Lightning Surge Protector for Standard Signal Line (ultra-slim) P.462

MDP-24-1 Lightning Surge Protector for Standard Signal Line & Pulse Use P.462

MDP-65-1 Lightning Surge Protector for Standard Signal Line & Pulse Use P.462

MDK-24 Lightning Surge Protector for Standard Signal Line Use P.463

MDJST Lightning Surge Protector for Standard Signal Use (fast response: 3 nsec.) P.463

MMDHLightning Surge Protector for Standard Signal Line Use (high speed/high discharge current capacity)

P.463

MMD Lightning Surge Protector for Standard Signal Line Use (high discharge current capacity) ***

MD72W Lightning Surge Protector for Two-wire Signal Loop (ultra-slim) P.463

MD72WD Lightning Surge Protector for Two-wire Signal Loop (ultra-slim; 2 channels) P.463

MD73W Lightning Surge Protector for Three-wire Signal Loop (ultra-slim) P.463

MD6N-24 Lightning Surge Protector for Standard Signal Line & Pulse Use (conduit mount, weather-proof) P.464

MD6N-65 Lightning Surge Protector for Standard Signal Line & Pulse Use (conduit mount, weather-proof) P.464

MD6T-24 Lightning Surge Protector for Standard Signal Line & Pulse Use (conduit mount, weather-proof) P.464

MD6T-65 Lightning Surge Protector for Standard Signal Line & Pulse Use (conduit mount, weather-proof) P.464

MD6P-24 Lightning Surge Protector for Standard Signal Line & Pulse Use (conduit mount, weather-proof) P.464

MD6P-65 Lightning Surge Protector for Standard Signal Line & Pulse Use (conduit mount, weather-proof) P.464

■ Sensor Use

Model Function Page

MD7TC Lightning Surge Protector for Thermocouple (ultra-slim) P.465

MDP-TC Lightning Surge Protector for Thermocouple Use P.465

MD7RB Lightning Surge Protector for RTD (ultra-slim) P.465

MDP-RB Lightning Surge Protector for RTD Use P.465

MD7PM Lightning Surge Protector for Potentiometer (ultra-slim) P.465

MDP-PM Lightning Surge Protector for Potentiometer Use P.465

MD7LC Lightning Surge Protector for Strain Gauge Use (ultra-slim) P.466

MDP-LC Lightning Surge Protector for Strain Gauge Use P.466

MDK-LC Lightning Surge Protector for Strain gauge Use P.466

MD-LC2 Lightning Surge Protector for Strain gauge Use (6-wire remote sensing) P.466

MDK-LV Lightning Surge Protector for Signal Line with Excitation Use P.466

MD7JS Lightning Surge Protector for Self-Synch Use (ultra-slim) P.467

MDP-JS Lightning Surge Protector for Self-Synch Use P.467

MD7PL Lightning Surge Protector for Pulse Signal (ultra-slim) P.467

MDP-SP Lightning Surge Protector for Low Frequency Use P.467

MDR2 Lightning Surge Protector for Multi-channel Use (high discharge current capacity) P.467

■ Transmission Line Use

Model Function Page

MD74R Lightning Surge Protector for RS-485/RS-422 (ultra-slim) P.468

MDP-4R Lightning Surge Protector for RS-485/RS-422 P.468

MDW5-4R Lightning Surge Protector for RS-485/RS-422 (full-duplex) P.468

MDW2A-4R Lightning Surge Protector for RS-485/RS-422 (life monitor) P.468

MDCAT Lightning Surge Protector for Ethernet (PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T) P.468

MDM5E-A Lightning Surge Protector for Ethernet (100 BASE-TX / 10 BASE-T) P.468

SHSP 8-Port Ethernet Switch (with surge protector) P.469

MD7AST,MDPA-24,MDPA-65,MDM2A-24,MDM2A-65,MD7ST,MDP-24-1,MDP-65-1,MDK-24,MDJST,MMDH,MMD,MD72W,MD72WD,MD73W,MD6N-24,MD6N-65,MD6T-24,MD6T-65,MD6P-

24,MD6P-65,MD7TC,MDP-TC,MD7RB,MDP-RB,MD7PM,MDP-PM,MD7LC,MDP-LC,MDK-LC,MD-LC2,MDK-LV,MD7JS,MDP-JS,MD7PL,MDP-SP,MDR2,MD74R,MDP-4R,MDW5-

4R,MDW2A-4R,MDCAT,MDM5E-A,SHSP,MD7PA,MDP-PA,MD7LWA,MDP-LWA,MD-DNM,MD-DNS,MD7FB,MDP-DM3,MDP-EC,MDP-MFA,MDP-FT,MD-INS,MD-TL,MDP-TL,MDA-

TL,MD7AP,MDP-100,MDP-200,MA-100,MA-200,MAA,MAAC,MMAJ,MMA,MMAH,MAX,MAH,MMH,MH-105A,MH-110A,MH-130A,MH-205A,MH-210A,MH-230A,MH-1201,MH-2201,MH-

2203,MD7DP,MDP-D,MDHA,MDH,MAT2,MAKF,C-106A-1,A-33,MD7F,MD7G,MBS,CNB,BX-W1

Page 2: 460 TL,MD7AP,MDP-100,MDP-200,MA-100,MA-200,MAA ...Data sheets available on Web in PDF. Visit M-System Data Library at ISP ’12 J 460 460 Lightning Surge Protectors for Electronics

Lightning Surge Protectors for Electronics Equipment M-RESTER

Specifications are subject to change without notice.ISP ’12

J

461

461Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Lightning Surge ProtectorsM-RESTER

Lightning Surge Protectors

Standard Signal Line & Pulse Use

Sensor Use

Transmission Line Use

Power Supply Use

DC Power Supply UseOne-port Surge Protector

Accessories

To find a product in the list with “***”, visit M-System Data Library.If you cannot find a product here, please contact: [email protected]

Model Function Page

MD7PA Lightning Surge Protector for PROFIBUS-PA (ultra-slim) P.469

MDP-PA Lightning Surge Protector for PROFIBUS-PA P.469

MD7LWA Lightning Surge Protector for LONWORKS (ultra-slim, FTT-10A) P.470

MDP-LWA Lightning Surge Protector for LONWORKS (FTT-10A) P.470

MD-DNM Lightning Surge Protector for DeviceNet (load capacity 8A) P.470

MD-DNS Lightning Surge Protector for DeviceNet (load capacity 2A) P.470

MD7FB Lightning Surge Protector for FOUNDATION Fieldbus (ultra-slim) P.470

MDP-DM3 Lightning Surge Protector for MsysNet Use ***MDP-EC Lightning Surge Protector for EC-Cable Use ***

MDP-MFA Lightning Surge Protector for Telemetering Use (50 bps) ***

MDP-FT Lightning Surge Protector for Telemetering Use (3.4 kHz) ***

MD-INS Lightning Surge Protector for ISDN Circuit Use ***

MD-TL Lightning Surge Protector for Telecommunication Line Use ***

MDP-TL Lightning Surge Protector for Telecommunication Line Use ***

MDA-TL Lightning Surge Protector for Analog Telecom Line Use (life monitor) ***

■ Power Supply Use

Model Function Page

MD7AP Lightning Surge Protector for AC Power Supply (max. 3A; ultra-slim) P.470

MDP-100 Lightning Surge Protector for AC/DC Power Supply Use (1A) P.470

MDP-200 Lightning Surge Protector for AC/DC Power Supply Use (1A) P.470

MA-100 Lightning Surge Protector for Power Supply (2A) P.471

MA-200 Lightning Surge Protector for Power Supply (2A) P.471

MAALightning Surge Protector for Power Supply Use (5A; high discharge current capacity; life monitor)

P.471

MAACLightning Surge Protector for Power Supply Use (5A; high discharge current capacity; life monitor/surge counter)

P.471

MMAJ Lightning Surge Protector for Power Supply Use (fast responce: 3 nsec.) P.471

MMA Lightning Surge Protector for Power Supply Use (10A;high discharge current capacity) P.471

MMAH Lightning Surge Protector for Power Supply Use (10A; high speed/high discharge current capacity) P.471

MAX Lightning Surge Protector for Power Supply Use (5A; high discharge current capacity) P.472

MAH Lightning Surge Protector for Power Supply Use (20A) ***

MMH Lightning Surge Protector for Power Supply Use (10–30A; replaceable arrester module) P.472

MH-105A Lightning Surge Protector for Power Supply Use (5A) ***

MH-110A Lightning Surge Protector for Power Supply Use (10A) ***

MH-130A Lightning Surge Protector for Power Supply Use (30A) ***

Model Function Page

MH-205A Lightning Surge Protector for Power Supply Use (5A) ***

MH-210A Lightning Surge Protector for Power Supply Use (10A) ***

MH-230A Lightning Surge Protector for Power Supply Use (30A) ***

MH-1201 Lightning Surge Protector for Power Supply Use (200A) ***

MH-2201 Lightning Surge Protector for Power Supply Use (200A) ***

MH-2203 Lightning Surge Protector for Power Supply Use (200A) ***

■ DC Power Supply Use

Model Function Page

MD7DP Lightning Surge Protector for DC Power Supply (max. 1.2A; ultra-slim) P.472

MDP-D Lightning Surge Protector for DC Power Supply Use P.472

MDHA Lightning Surge Protector for Power Supply Use (DC power use; life monitor) P.472

MDH Lightning Surge Protector for Power Supply Use (DC power use) P.472

■ One-port Surge Protector

Model Function Page

MAT2 Lightning Surge Protector for Three-phase Power Supply P.473

MAKF One-port Surge Protector for Power Supply Use P.473

■ Accessories

Model Function Page

C-106A-1 M-RESTER Tester P.473

A-33 DIN Rail Mounting Adaptor P.473

MD7F Loop Disconnect Fuse ***MD7G Terminal Block For Grounding (ultra-slim) ***MBS Single Mount Adaptor ***CNB Wiring Bridge ***BX-W1 Outdoor Housing (weather-proof) P.473

Page 3: 460 TL,MD7AP,MDP-100,MDP-200,MA-100,MA-200,MAA ...Data sheets available on Web in PDF. Visit M-System Data Library at ISP ’12 J 460 460 Lightning Surge Protectors for Electronics

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12

J

462

462 Lightning Surge Protectors for Electronics Equipment M-RESTERSignal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Lightning Surge ProtectorsM-RESTER

Standard Signal Line & Pulse Use

Lightning Surge Protectors

Sensor Use

Transmission Line Use

Power Supply Use

DC Power Supply UseOne-port Surge Protector

Accessories

4–20mA & Pulse Signal, Ultra-slim Type

Model MD7ST-24 MD7ST-60Max. Cont. Operat. Volt. (Uc) 30V 70V

Voltage Protection Level (Up) 60V max. 115V max.

Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20 kA (8/20 μs), 1.0 kA (10/350 μs.)Nominal Current (IN) 250 mAInternal Resistance (Ω ±10%, per line)

4.7 Ω w/o fuse7.5 Ω w/ fuse

10 Ω w/o fuse12.5 Ω w/ fuse

Test Standard IEC 61643-21 (Categories C1, C2, D1)

4–20mA & Pulse Signal, Plug-in Type

Model MDP-24-1 MDP-65-1Max. Cont. Operat. Volt. (Uc) 30V min. 70V min.

Voltage Protection Level (Up) 40V max.@1kV (100A) 45V max.@2kV (1kA)

80V max.@1kV (100A) 110V max.@2kV (1kA)

Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 100 mA

Internal Resistance 20 Ω ±10% (incl. return)

Test Standard IEC 61643-21 (Categories C1, C2)

4–20mA & Pulse Signal, Ultra-slim Type, with Life Monitor

Model MD7AST-24 MD7AST-60Max. Cont. Operat. Volt. (Uc) 30V 70V

Voltage Protection Level (Up) 60V max. 115V max.

Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20 kA (8/20 μs), 1.0 kA (10/350 μs.)Nominal Current (IN) 250 mAInternal Resistance 4.7 Ω ±10% per line 10 Ω ±10% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

4–20mA & Pulse Signal, Plug-in Type, with Life Monitor

Model MDPA-24 MDPA-65Max. Cont. Operat. Volt. (Uc) 30V min. 70V min.

Voltage Protection Level (Up) 45V max.@1kV (100A) 50V max.@2kV (1kA)

85V max.@1kV (100A) 100V max.@2kV (1kA)

Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 100 mAInternal Resistance 20 Ω ±10% (incl. return)Test Standard IEC 61643-21 (Categories C1, C2)

4–20mA & Pulse Signal, Plug-in Type, with Life Monitor

Model MDM2A-24 MDM2A-65Discharge Voltage 30V min. 70V min.Max. Surge Voltage 45V max. 85V max.Response Time 0.1 μsec. max.Discharge Current 5000A (8/20 μsec.)Max. Load Current 100 mAInternal Resistance Approx. 20 Ω (incl. return)Test Standard ----

■ Standard Signal Line & Pulse Use

LIFEMONITOR

MD7AST,MDPA-24,MDPA-65,MDM2A-24,MDM2A-65,MD7ST,MDP-24-1,MDP-65-1,

LIFEMONITOR

LIFEMONITOR

Page 4: 460 TL,MD7AP,MDP-100,MDP-200,MA-100,MA-200,MAA ...Data sheets available on Web in PDF. Visit M-System Data Library at ISP ’12 J 460 460 Lightning Surge Protectors for Electronics

Lightning Surge Protectors for Electronics Equipment M-RESTER

Specifications are subject to change without notice.ISP ’12

J

463

463Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Lightning Surge ProtectorsM-RESTER

Lightning Surge Protectors

Standard Signal Line & Pulse Use

Sensor Use

Transmission Line Use

Power Supply Use

DC Power Supply UseOne-port Surge Protector

Accessories

Two-Wire Transmitter Loop, Ultra-slim Type

Model MD72W-07 MD72W-16 MD72W-32 MD72W-55Max. Cont. Operat. Volt. (Uc) ±7V ±16V ±32V ±55VVoltage Protection Level (Up) 20V max. 30V max. 50V max. 80V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20 kA (8/20 μs), 1.0 kA (10/350 μs.)Nominal Current (IN) 400 mA w/o fuse, 250 mA w/ fuseInternal Resistance (Ω ±20%, per line) 2.2 Ω w/o fuse, 4 Ω w/ fuse

Test Standard IEC 61643-21 (Categories C1, C2, D1)

Two-Wire Transmitter Loop, 2 channels, Ultra-slim Type

Model MD72WD-07 MD72WD-16 MD72WD-32Max. Cont. Operat. Volt. (Uc) ±7V ±16V ±32VVoltage Protection Level (Up) 30V max. 45V max. 70V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20 kA (8/20 μs), 1.0 kA (10/350 μs.)Nominal Current (IN) 250 mAInternal Resistance 4.7 Ω ±20% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

4–20mA & Pulse Signal, High Speed, Plug-in Type

Model MDJST-12 MDJST-24 MDJST-48Max. Cont. Operat. Volt. (Uc) ±18V ±36V ±60VVoltage Protection Level (Up) ±30V max. ±50V max. ±90V max.Response Time 3 nanosec. max.Max. Discharge Curr. (Imax) 20 kA (8/20 μs)Nominal Current (IN) 1AInternal Resistance 3Ω max.Test Standard IEC 61643-21 (Categories C1, C2)

4–20mA & Pulse Signal, Low Profile Type

Model MDK-24Discharge Voltage 30V min.Max. Surge Voltage 40V max.Response Time 0.1 μsec. max.Discharge Current 5000A (8/20 μsec.)Max. Load Current 100 mAInternal Resistance 20 Ω ±5%Test Standard ----

4–20mA & Pulse Signal, High Speed, High Discharge Current Capacity

Model MMDH-24Discharge Voltage ±40V min.Max. Surge Voltage ±50V max.Response Time 4 nanosec.Discharge Current 20000A (8/20 μsec.)Max. Load Current 0.1 A

Internal Resistance ≤0.4 Ω (incl. return)

Test Standard ----

Three-Wire Transmitter Loop, Ultra-slim Type

Model MD73WMax. Cont. Operat. Volt. (Uc) ±32VVoltage Protection Level (Up) ±60V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20 kA (8/20 μs), 1.0 kA (10/350 μs.)Nominal Current (IN) 400 mAInternal Resistance ≤2.2 Ω ±20% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

■ Standard Signal Line & Pulse Use

MDK-24,MDJST,MMDH,MD72W,MD72WD,MD73W,

Page 5: 460 TL,MD7AP,MDP-100,MDP-200,MA-100,MA-200,MAA ...Data sheets available on Web in PDF. Visit M-System Data Library at ISP ’12 J 460 460 Lightning Surge Protectors for Electronics

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12

J

464

464 Lightning Surge Protectors for Electronics Equipment M-RESTERSignal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Lightning Surge ProtectorsM-RESTER

Standard Signal Line & Pulse Use

Lightning Surge Protectors

Sensor Use

Transmission Line Use

Power Supply Use

DC Power Supply UseOne-port Surge Protector

Accessories

4–20mA & Pulse Signal, Conduit Mount, Weather-Proof (Terminal Block Connection Type)

Model MD6T-24 MD6T-65Discharge Voltage 30V min. 70V min.Max. Surge Voltage 40V max. 100V max.Response Time 4 nanosec. max.Discharge Current 10000A (8/20 μsec.)Max. Load Current 100 mAInternal Resistance Approx. 22 Ω (incl. return)

Approvals

• FM intrinsically safe• CENELEC intrinsically

safe (ATEX)• CENELEC flameproof

(ATEX)• FM nonincendive

• CENELEC flameproof (ATEX)

4–20mA & Pulse Signal, Conduit Mount, Weather-Proof (Leadwire Connection, Pipe Nipple Type)

Model MD6N-24 MD6N-65Discharge Voltage 30V min. 70V min.Max. Surge Voltage 40V max. 100V max.Response Time 4 nanosec. max.Discharge Current 10000A (8/20 μsec.)Max. Load Current 100 mAInternal Resistance Approx. 22 Ω (incl. return)

Approvals

• FM intrinsically safe• CENELEC intrinsically

safe (ATEX)• FM explosion-proof• CENELEC flameproof

(ATEX)• FM nonincendive

• FM explosion-proof• CENELEC flameproof

(ATEX)

4–20mA & Pulse Signal, Conduit Mount, Weather-Proof (Leadwire Connection, Stopping Plug Type)

Model MD6P-24 MD6P-65Discharge Voltage 30V min. 70V min.Max. Surge Voltage 40V max. 100V max.Response Time 4 nanosec. max.Discharge Current 10000A (8/20 μsec.)Max. Load Current 100 mAInternal Resistance Approx. 22 Ω (incl. return)

Approvals

• FM intrinsically safe• CENELEC intrinsically

safe (ATEX)• FM explosion-proof• CENELEC flameproof

(ATEX)• FM nonincendive

• FM explosion-proof• CENELEC flameproof

(ATEX)

■ Standard Signal Line & Pulse Use

MD6N-24,MD6N-65,MD6T-24,MD6T-65,MD6P-24,MD6P-65,

Page 6: 460 TL,MD7AP,MDP-100,MDP-200,MA-100,MA-200,MAA ...Data sheets available on Web in PDF. Visit M-System Data Library at ISP ’12 J 460 460 Lightning Surge Protectors for Electronics

Lightning Surge Protectors for Electronics Equipment M-RESTER

Specifications are subject to change without notice.ISP ’12

J

465

465Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Lightning Surge ProtectorsM-RESTER

Lightning Surge Protectors

Standard Signal Line & Pulse Use

Sensor Use

Transmission Line Use

Power Supply Use

DC Power Supply UseOne-port Surge Protector

Accessories

Thermocouple, Ultra-slim Type

Model MD7TCMax. Cont. Operat. Volt. (Uc) 7.5VVoltage Protection Level (Up) 25V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 100 mAInternal Resistance 4.7 Ω ±10% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

Thermocouple, Plug-in Type

Model MDP-TCMax. Cont. Operat. Volt. (Uc) 7.5V min.Voltage Protection Level (Up) 16V max.@1kV (100A), 20V max.@2kV (1kA)Response Time 0.1 μsec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 100 mAInternal Resistance 20 Ω ±10% (incl. return)Test Standard IEC 61643-21 (Categories C1, C2)

RTD, Ultra-slim Type

Model MD7RBMax. Cont. Operat. Volt. (Uc) ±3V

Voltage Protection Level (Up) ±25V max.

Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 100 mAInternal Resistance 5.12 Ω ±0.3%, ±30 ppm/°C per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

RTD, Plug-in Type

Model MDP-RBMax. Cont. Operat. Volt. (Uc) ±6V min. (B to C), ±3V min. (B or C to A)

Voltage Protection Level (Up) ±40V max.@2kV (1kA) (2 to 3), ±25V max.@2kV (1kA) (2 or 3 to 1)

Response Time 0.1 μsec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 100 mAInternal Resistance 10 Ω ±0.1%, 30 ppm/°CTest Standard IEC 61643-21 (Categories C1, C2)

Potentiometer, Ultra-slim Type

Model MD7PMMax. Cont. Operat. Volt. (Uc) 7.5VVoltage Protection Level (Up) 25V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 100 mAInternal Resistance 4.7 Ω ±10% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

Potentiometer, Plug-in Type

Model MDP-PMMax. Cont. Operat. Volt. (Uc) 7.5V min.Voltage Protection Level (Up) 16V max.@1kV (100A), 25V max.@2kV (1kA)Response Time 0.1 μsec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 100 mAInternal Resistance 10 Ω ±0.1%, 30 ppm/°CTest Standard IEC 61643-21 (Categories C1, C2)

■ Sensor Use

MD7TC,MDP-TC,MD7RB,MDP-RB,MD7PM,MDP-PM,

Page 7: 460 TL,MD7AP,MDP-100,MDP-200,MA-100,MA-200,MAA ...Data sheets available on Web in PDF. Visit M-System Data Library at ISP ’12 J 460 460 Lightning Surge Protectors for Electronics

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12

J

466

466 Lightning Surge Protectors for Electronics Equipment M-RESTERSignal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Lightning Surge ProtectorsM-RESTER

Standard Signal Line & Pulse Use

Lightning Surge Protectors

Sensor Use

Transmission Line Use

Power Supply Use

DC Power Supply UseOne-port Surge Protector

Accessories

Strain Gauge, Ultra-slim Type

Model MD7LC-0* MD7LC-1

Max. Cont. Operat. Volt. (Uc)Line Side ±0.2VExc. Side 15V

Voltage Protection Level (Up)Line Side ±15V max. @0.2kV (1.2 / 50 μs) ±40V max. @6kV (1.2 / 50 μs)Exc. Side 30V max. @0.2kV (1.2 / 50 μs) 50V max. @6kV (1.2 / 50 μs)

Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 100A (8/20 μsec.) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) ---- 250 mAInternal Resistance ---- 1.5 Ω ±10% per lineTest Standard ---- IEC 61643-21 (Categories C1, C2, D1)

Strain Gauge, Plug-in Type

Model MDP-LC

Max. Cont. Operat. Volt. (Uc)

Line Side ±0.3V min.Exc. Side 15V min.

Voltage Protection Level (Up)

Line Side ±15V max.Exc. Side 30V max.

Response Time 5 nanosec. max.Max. Discharge Curr. (Imax)

Line Side 100A (8/20 μsec.), 25A (10/1000 μsec.)Exc. Side 50A (8/20 μsec.), 25A (10/1000 μsec.)

Test Standard IEC 61643-21 (Category C3)

Strain Gauge, 6-wire Remote Sensing

Model MD-LC2

Discharge VoltageLine Side ±0.3V min.Exc. Side 15V min.

Max. Surge Voltage

Line Side ±20V max.Exc. Side 40V max.

Response Time 4 nanosec. max.Discharge Current 5000A (8/20 μsec.)Test Standard ----

Strain Gauge, Low Profile Type

Model MDK-LC

Discharge VoltageLine Side ±0.3V min.Exc. Side 15V min.

Max. Surge Voltage

Line Side ±15V max.Exc. Side 30V max.

Response Time 5 nanosec. max.

Discharge CurrentLine Side 100A (8/20 μsec.)Exc. Side 50A (8/20 μsec.)

Test Standard ----

Signal Line with Excitation, Low Profile Type

Model MDK-LV

Discharge VoltageLine Side 10V min.Exc. Side 30V min.

Max. Surge Voltage

Line Side 20V max.Exc. Side 40V max.

Response Time 0.1 μsec. max.Discharge Current 5000A (8/20 μsec.)Test Standard ----

■ Sensor Use

* No CE marking.

MD7LC,MDP-LC,MDK-LC,MD-LC2,MDK-LV,

Page 8: 460 TL,MD7AP,MDP-100,MDP-200,MA-100,MA-200,MAA ...Data sheets available on Web in PDF. Visit M-System Data Library at ISP ’12 J 460 460 Lightning Surge Protectors for Electronics

Lightning Surge Protectors for Electronics Equipment M-RESTER

Specifications are subject to change without notice.ISP ’12

J

467

467Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Lightning Surge ProtectorsM-RESTER

Lightning Surge Protectors

Standard Signal Line & Pulse Use

Sensor Use

Transmission Line Use

Power Supply Use

DC Power Supply UseOne-port Surge Protector

Accessories

Self-Synch, Ultra-slim Type

Model MD7JSMax. Cont. Operat. Volt. (Uc) ±130V

Voltage Protection Level (Up) ±450V max.

Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 500 mAInternal Resistance 2 Ω ±10% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

Self-Synch, Plug-in Type

Model MDP-JSMax. Cont. Operat. Volt. (Uc) ±170V min. (A to B to C)

Voltage Protection Level (Up) ±350V max.@1kV (100A) (1 to 2 to 3), ±450V max.@2kV (1kA) (1 to 2 to 3)

Response Time 0.1 μsec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 500 mAInternal Resistance Approx. 2 Ω per wireTest Standard IEC 61643-21 (Categories C1, C2)

2-Point Pulse with Common Negative, Ultra-slim Type

Model MD7PL-P Positive (PNP)

MD7PL-N Negative (NPN)

Max. Cont. Operat. Volt. (Uc) -30V +30VVoltage Protection Level (Up) -50V max. +50V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 100 mAInternal Resistance 11 Ω ±10% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

Low Frequency Pulse, Plug-in Type

Model MDP-SP

Max. Cont. Operat. Volt. (Uc) 14V min.Voltage Protection Level (Up) 30V max.@1kV (100A), 30V max.@2kV (1kA)Response Time 0.1 μsec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 50 mAInternal Resistance 10 Ω ±10%Test Standard IEC 61643-21 (Categories C1, C2)

High Discharge, 8-point Pulse Signal, Terminal Board Type

Model MDR2-8NY Negative (NPN)

MDR2-8NA Negative (NPN) with

Leakage current Indicator

MDR2-8PY Positive (PNP)

MDR2-8PA Positive (PNP) with

Leakage current IndicatorMax. Cont. Operat. Volt. (Uc) +30V -30VVoltage Protection Level (Up) @4kV / 2kA (1.2 / 50 μsec.) +50V +60V -50V -60VResponse Time 4 nanosec. max.Max. Discharge Curr. (Imax) 10kANominal Current (IN) 150 mAInternal Resistance 22 Ω ±20%Test Standard IEC 61643-21 (Categories C1, C2)

■ Sensor Use

MD7JS,MDP-JS,MD7PL,MDP-SP,MDR2,

Page 9: 460 TL,MD7AP,MDP-100,MDP-200,MA-100,MA-200,MAA ...Data sheets available on Web in PDF. Visit M-System Data Library at ISP ’12 J 460 460 Lightning Surge Protectors for Electronics

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12

J

468

468 Lightning Surge Protectors for Electronics Equipment M-RESTERSignal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Lightning Surge ProtectorsM-RESTER

Standard Signal Line & Pulse Use

Lightning Surge Protectors

Sensor Use

Transmission Line Use

Power Supply Use

DC Power Supply UseOne-port Surge Protector

Accessories

RS-485/RS-422, Ultra-slim Type

Model MD74RMax. Cont. Operat. Volt. (Uc) ±5VVoltage Protection Level (Up) ±25V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 100 mAInternal Resistance 2 Ω ±10% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

RS-485/RS-422, Plug-in Type

Model MDP-4RMax. Cont. Operat. Volt. (Uc) ±5V min. (B to C)Voltage Protection Level (Up) ±20V max. (2 to 3)Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 100 mAInternal Resistance Approx. 4.5 Ω (incl. return)Test Standard IEC 61643-21 (Categories C1, C2)

RS-485/RS-422, Plug-in Type with Life Monitor

Model MDW2A-4RDischarge Voltage ±5V min. (7 to 8)Max. Surge Voltage ±25V max. (4 to 5)Response Time 4 nanosec. max.Discharge Current 5000A (8/20 μsec.)Max. Load Current 100 mAInternal Resistance Approx. 5 Ω (incl. return)Test Standard ----

RS-485/RS-422, Full-duplex

Model MDW5-4RDischarge Voltage ±5V min. (6 to 7, 8 to 9)Max. Surge Voltage ±25V max. (1 to 2, 3 to 4)Response Time 4 nanosec. max.Discharge Current 10kA (8/20 μsec.)Max. Load Current 100 mAInternal Resistance Approx. 4 Ω (incl. return)Test Standard ----

Ethernet, 100 BASE-TX / 10 BASE-T

Model MDM5E-ADischarge Voltage ±6V min.Max. Surge Voltage 38V max.Response Time 4 nanosec. max.Discharge Current 500A (8/20 μsec.)Series Resistance Approx. 0 ΩImpulse durability Category c1Test Standard IEC 61643-21 : 2000

Ethernet, PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T

Model MDCAT-5E (CAT5e) MDCAT-6 (CAT6)Max. Cont. Operat. Volt. (Uc) ±6V ±3.3VVoltage Protection Level (Up) ±15V max. @2kV ±10V max. @2kVResponse Time 4 nanosec. max.Max. Discharge Curr. (Imax) 100ANominal Current (IN) 1AInternal Resistance Approx. 0 ΩTest Standard IEC 61643-21 (Categories C1, C2)

■ Transmission Line Use

MD74R,MDP-4R,MDW5-4R,MDW2A-4R,MDCAT,MDM5E-A,

LIFEMONITOR

Page 10: 460 TL,MD7AP,MDP-100,MDP-200,MA-100,MA-200,MAA ...Data sheets available on Web in PDF. Visit M-System Data Library at ISP ’12 J 460 460 Lightning Surge Protectors for Electronics

Lightning Surge Protectors for Electronics Equipment M-RESTER

Specifications are subject to change without notice.ISP ’12

J

469

469Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Lightning Surge ProtectorsM-RESTER

Lightning Surge Protectors

Standard Signal Line & Pulse Use

Sensor Use

Transmission Line Use

Power Supply Use

DC Power Supply UseOne-port Surge Protector

Accessories

PROFIBUS-PA, Ultra-slim Type

Model MD7PAMax. Cont. Operat. Volt. (Uc) ±32VVoltage Protection Level (Up) ±60V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 400 mAInternal Resistance 1.5 Ω ±10% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

PROFIBUS-PA, Plug-in Type

Model MDP-PAMax. Cont. Operat. Volt. (Uc) 27V min.Voltage Protection Level (Up) ±60V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 500 mAInternal Resistance ≤3.3 Ω (incl. return)Test Standard IEC 61643-21 (Categories C1, C2)

■ Transmission Line Use

8-Port Ethernet Switch (with surge protector)

Surge protector function for each port ◆ Protects Ethernet devices from surges

entering through LAN cables

◆ Surge protector life monitor function with LED and contact output alarm

◆ Data transfer rate can be fixedModel: SHSP

■ LAN PORT SPECIFICATIONSStandards IEEE 802.3, IEEE 802.3u, IEEE 802.3xNumber of ports 8; All ports support AUTO-MDIX*

Data transfer rate10 Mbps (10 BASE-T), 100 Mbps (100 BASE-TX); Supports Auto-Negotiation

Cable 10 BASE-T (STP cable, category 5)100 BASE-TX (STP cable, category 5e)

Maximum segment length 100 metersSwitching Store & Forward

Flow controlFull duplex PAUSE FramesHalf duplex Back pressure

Buffer 64 KBMAC address table 1024

■ SURGE PROTECTOR PERFORMANCECompliant standard EN61000-4-5 level X Between ports 1kV (combination waveform)** Port to G 10kV (combination waveform) FG (shield) to G 15kV (combination waveform)***

Voltage protection level

Port to FG or G 160V min.Between each port 160V min.

FG to G 160V min. (with the shortcircuit bar removed)

SHSP,MD7PA,MDP-PA,

LIFEMONITOR

* Automatically sensing cable type, straight-through or cross-over.** RJ-45 connector contact is out of the scope of this protection. Using twisted-pair (STP) LAN cable is effective to reduce risk of fusing contact.*** With the shortcircuit bar

Page 11: 460 TL,MD7AP,MDP-100,MDP-200,MA-100,MA-200,MAA ...Data sheets available on Web in PDF. Visit M-System Data Library at ISP ’12 J 460 460 Lightning Surge Protectors for Electronics

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12

J

470

470 Lightning Surge Protectors for Electronics Equipment M-RESTERSignal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Lightning Surge ProtectorsM-RESTER

Standard Signal Line & Pulse Use

Lightning Surge Protectors

Sensor Use

Transmission Line Use

Power Supply Use

DC Power Supply UseOne-port Surge Protector

Accessories

1A Load Rating, Plug-in Type

Model MDP-100 MDP-200Max. Line Volt. (Uc) 120V AC 250V ACVoltage Protection Level (Up) 400V max. 800V max.Response Time 0.1 μsec. max.Max. Discharge Curr. (Imax) 1000A (8/20 μsec.)Nominal Current (IN) 1AInternal Resistance ≤0.4 Ω (incl. return)Test Standard IEC 61643-1 (Class III)

3A Load Rating, Ultra-slim Type

Model MD7AP-100 MD7AP-200Max. Cont. Operat. Volt. (Uc) 140V AC 275V ACVoltage Protection Level (Up) ±550V max. ±850V max.Response Time 20 nanosec. max.Max. Discharge Curr. (Imax) 10kA (8/20 μsec.)Nominal Current (IN) 3ATest Standard IEC 61643-21 (Categories C1, C2)

■ Power Supply Use

■ Transmission Line Use

DeviceNet

Model MD-DNM MD-DNS

Discharge VoltageLine Side ±5V min.Exc. Side 26V min.

Max. Surge Voltage

Line Side ±15V max.Exc. Side 120V max.

Response Time 0.1 μsec. max.

Discharge CurrentLine Side

1500A Exc. Side

Load Capacity 8A 2ATest Standard ----

FOUNDATION Fieldbus, Ultra-slim Type

Model MD7FBMax. Cont. Operat. Volt. (Uc) ±32VVoltage Protection Level (Up) ±60V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 400 mAInternal Resistance 1.5 Ω ±10% per lineTest Standard IEC 61643-21 (Categories C1, C2, D1)

LONWORKS (FTT-10A), Ultra-slim Type

Model MD7LWAMax. Cont. Operat. Volt. (Uc) ±1.5V min.Voltage Protection Level (Up) ±30V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 100 mAInternal Resistance ≤3.3 Ω (incl. return)Test Standard IEC 61643-21 (Categories C1, C2, D1)

LONWORKS (FTT-10A), Plug-in Type

Model MDP-LWAMax. Cont. Operat. Volt. (Uc) ±1.5V min.Voltage Protection Level (Up) ±40V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 100 mAInternal Resistance ≤3.3 Ω (incl. return)Test Standard IEC 61643-21 (Categories C1, C2)

MD7LWA,MDP-LWA,MD-DNM,MD-DNS,MD7FB,MD7AP,MDP-100,MDP-200,

Page 12: 460 TL,MD7AP,MDP-100,MDP-200,MA-100,MA-200,MAA ...Data sheets available on Web in PDF. Visit M-System Data Library at ISP ’12 J 460 460 Lightning Surge Protectors for Electronics

Lightning Surge Protectors for Electronics Equipment M-RESTER

Specifications are subject to change without notice.ISP ’12

J

471

471Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Lightning Surge ProtectorsM-RESTER

Lightning Surge Protectors

Standard Signal Line & Pulse Use

Sensor Use

Transmission Line Use

Power Supply Use

DC Power Supply UseOne-port Surge Protector

Accessories

2A Load Rating, Plug-in Type

Model MA-100 MA-200Discharge Voltage 190V min. 410V min.Max. Surge Voltage 350V max. 700V max.Response Time 0.1 μsec. max.Discharge Current 1000A (8/20 μsec.)Max. Load Current 2AVoltage Drop ≤2V (50/60Hz)Test Standard ----

5A Load Rating, with Life Monitor

Model MAA-100 MAA-200Discharge Voltage 190V min. 410V min.Max. Surge Voltage 380V max. 700V max.Response Time 0.01 μsec. max.Discharge Current 10000A (8/20 μsec.)Max. Load Current 5AInternal Resistance ≤0.5 Ω (incl. return)Test Standard ----

5A Load Rating, with Life Monitor / Surge Counter

Model MAAC-100 MAAC-200Discharge Voltage 190V min. 410V min.Max. Surge Voltage 400V max. 750V max.Response Time 0.01 μsec. max.Discharge Current 10000A (8/20 μsec.)Max. Load Current 5AInternal Resistance ≤0.5 Ω (incl. return)Test Standard ----

10A/20A/30A Load Rating, Wall-mounted, High Speed, High Discharge Current Capacity

Model MMAJ-100 MMAJ-200Max. Cont. Operat. Volt. (Uc) 132V AC 264V ACVoltage Protection Level (Up) 900V max. 1500V max.Response Time 3 nanosec.Max. Discharge Curr. (Imax) 10kA, 20kAMax. Load Current 10A, 20A, 30ATest Standard IEC 61643-1 (Class II, III)

10A Load Rating, Wall-mounted, High Speed, High Discharge Current Capacity

Model MMAH-100 MMAH-200Discharge Voltage 190V min. 410V min.Max. Surge Voltage 400V max 750V max.Response Time 4 nanosec.Discharge Current 20000A (8/20 μsec.)Max. Load Current 10AInternal Resistance ≤0.5 Ω (incl. return)Test Standard ----

10A Load Rating, Wall-mounted

Model MMA-100 MMA-200Discharge Voltage 190V min. 410V min.Max. Surge Voltage 350V max 700V max.Response Time 0.01 μsec. max.Discharge Current 10000A (8/20 μsec.)Max. Load Current 10AInternal Resistance ≤0.5 Ω (incl. return)Test Standard ----

■ Power Supply Use

LIFEMONITOR

MA-100,MA-200,MAA,MAAC,MMAJ,MMA,MMAH,

LIFEMONITOR

Page 13: 460 TL,MD7AP,MDP-100,MDP-200,MA-100,MA-200,MAA ...Data sheets available on Web in PDF. Visit M-System Data Library at ISP ’12 J 460 460 Lightning Surge Protectors for Electronics

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12

J

472

472 Lightning Surge Protectors for Electronics Equipment M-RESTERSignal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Lightning Surge ProtectorsM-RESTER

Standard Signal Line & Pulse Use

Lightning Surge Protectors

Sensor Use

Transmission Line Use

Power Supply Use

DC Power Supply UseOne-port Surge Protector

Accessories

DC Power Supply Line, 1.2A Load Rating, Ultra-slim Type

Model MD7DP-12 MD7DP-24Max. Cont. Operat. Volt. (Uc) 14V 27VVoltage Protection Level (Up) ±150V max. ±170V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)Nominal Current (IN) 1.2AInternal Resistance ≤0.8 Ω (incl. return)Test Standard IEC 61643-21 (Categories C1, C2, D1)

DC Power Supply Line, 1A Load Rating, Plug-in Type

Model MDP-D12 MDP-D24Max. Cont. Operat. Volt. (Uc) 14V min. 30V min.Voltage Protection Level (Up) 20V max. 40V max.Response Time 4 nanosec. max.Max. Discharge Curr. (Imax) 5000A (8/20 μsec.)Nominal Current (IN) 1AInternal Resistance ≤0.6 Ω (incl. return)Test Standard IEC 61643-1 (Class III)

DC Power Supply Line, 5A Load Rating, Plug-in Type

Model MDH-12 MDH-24 MDH-48Discharge Voltage 24V min. 50V min. 88V min.Max. Surge Voltage 70V max. 140V max. 210V max.Response Time 0.1 μsec. max.Discharge Current 2000A (8/20 μsec.)Max. Load Current 5AInternal Voltage Drop ≤1VTest Standard ----

DC Power Supply Line, 5A Load Rating, with Life Monitor

Model MDHA-12 MDHA-24Discharge Voltage ±15V min. ±30V min.Max. Surge Voltage ±80V max. ±120V max.Response Time 4 nanosec. max.Discharge Current 10000A (8/20 μsec.)Max. Load Current 5AInternal Resistance ≤0.2 Ω (incl. return)Test Standard ----

LIFEMONITOR

5A Load Rating, Replaceable Surge Absorber

Model MAX-100 MAX-200Discharge Voltage 190V min. 410V min.Max. Surge Voltage 350V max. 700V max.Response Time 0.01 μsec. max.Discharge Current 10000A (8/20 μsec.)Max. Load Current 5AInternal Resistance ≤0.5 Ω (incl. return)Test Standard ----

Medium Capacity 10A, 30A, Replaceable Surge Absorber

Model MMH-110 MMH-130 MMH-210 MMH-230Discharge Voltage 130V min. 285V min.Max. Surge Voltage 350V max. 700V max.Response Time 0.01 μsec. max.Discharge Current 10000A (8/20 μsec.)Max. Load Current 10A 30A 10A 30AVoltage Drop ≤1V (50/60Hz)Test Standard ----

■ Power Supply Use

■ DC Power Supply Use

MAX,MMH,MD7DP,MDP-D,MDHA,MDH,

Page 14: 460 TL,MD7AP,MDP-100,MDP-200,MA-100,MA-200,MAA ...Data sheets available on Web in PDF. Visit M-System Data Library at ISP ’12 J 460 460 Lightning Surge Protectors for Electronics

Lightning Surge Protectors for Electronics Equipment M-RESTER

Specifications are subject to change without notice.ISP ’12

J

473

473Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electric Actuators& Position Sensors

Lightning Surge Protectors

Lightning Surge ProtectorsM-RESTER

Lightning Surge Protectors

Standard Signal Line & Pulse Use

Sensor Use

Transmission Line Use

Power Supply Use

DC Power Supply UseOne-port Surge Protector

Accessories

Three-phase Power Supply

Model MAT2-240 MAT2-440Max. Cont. Operat. Volt. (Uc) 240V AC 440V ACVoltage Protection Level (Up) 1500V 2500VResponse Time 4 nanosec. max.Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 40kA (8/20 μsec.)Nominal Current (IN) 10kA (8/20 μsec.), 20kA (8/20 μsec.)Test Standard IEC 61643-1 (Class II)

One-port Surge Protector

Model MAKF-120 MAKF-240 MAKF-280 MAKF-400 MAKF-480Uc (AC) 150V 275V 320V 440V 530VDischarge Voltage 250V min. 420V min. 460V min. 670V min. 820V min.

[email protected] (8/20ms) 600V max. 1000V max. 1100V max. 1500V max. 1800V [email protected] (8/20ms) 650V max. 1100V max. 1200V max. 1700V max. 2100V max.

Response Time 20 nanosec. max.Max. Discharge Curr. 20kA × twice (8/20 μsec.)Test Standard ----

■ One-port Surge Protector

■ Accessories

M-RESTER Testermodel: C-106A-1

DIN Rail Mounting Adaptormodel: A-33

Outdoor Housing (weather-proof) model: BX-W1

Connected in parallel between the power and ground lines regardless of load current

Connected in parallel between the power and ground lines regardless of load current

MAT2,MAKF,C-106A-1,A-33,BX-W1

◆ Applicable to single phase 2/3-wire and three-phase 3/4- wire system.

◆ Degraded head element is automatically sepa-rated from the power lines by the incorporated thermal breaker, and the LED lamp (turns off) and the relay contact alerts the failure status.

◆ Thermal breaker ensures degraded head element to be automatically separated from the power lines to prevent overheating.

◆ Head-base connection is keyed so that only a head element of correct line voltage can be mounted.