33 TR
ANS
DU
CER
S
TRANSDUCERS
• Threenewmodels–NT100,NT40and theNT25,anindustryfirst
• Basictohighlycustomizedmodels
• Hydraulicandpneumaticdesigns
• Threemodelswithaccuracyrangesof1%, .4%and.25%
• Vacuumrangesto10,000PSI
• IP69KsealavailablefortheNT25,enabling highpressurewashdowncapability
• Compactdesigns
• Customoutputsandrangesavailable
• Multipleindustryapplications
34
NT100
Features
• Vacuumto10,000PSIrange
• Variousoutputs
• Compactdesign
• 316stainlesssteelwettedparts
• Lowcost
• Industrial1%accuracy
• Customoutputsandrangesavailable
• OEMtestedandapproved
TheNT100SeriesPressureTransducerutilizespiezoresistancetechnologyinanallstainlesssteelbody.Itiscompactinsize,haslongtermstability,iseasytoinstall,andisveryeconomical,aswellasreliable.
TheNT100setsanewprice-performancestandardforlowcost,highvolumecommercialandindustrialapplications.
Application
• Hydraulic/mobilehydraulic
• Pneumaticsystems
• Foodandbeverageindustry
• Refrigerationsystems
• Pumpsandcompressors
• Energyandwatermanagement
• Constructionand agriculturalequipment
Description
How to Order (Example:PartNumber:NT100-03-B-0500-G-D00-4)
Model
NT100 – 03 – B - 0500 – G – D00 – 4
Media Connection
03=1/4"NPTMale**
Output
B=4-20mA
C=0-5V(3wire)**
Pressure Range(PSI)
0015
0025
0050
0100
0250
0500
1000
2500
5000**
Pressure Type
G=Gauge
ElectricalConnection
D00=4pinMini
9.4DIN
B00=3pinPackard**
Accuracy
4=1%**
**ConsultfactoryforfurtherOEMoptions
Transducers NT100
35
Transducers NT100
Specifications
InputSupplyVoltage 12-36VDCPressureRange VACto10,000PSIProofPressure 1.5xfullscaleBurstPressure 3xfullscaleFatigueLife Morethan4millioncycles
PerformanceAccuracy 1%Stability 0.2%fullscaleCompensatedTemperatures -10to75°C(14to167°F)OperatingTemperatures -20to80°C(-4to176°F)ZeroandSpanOffsetTolerance 1.5%
Mechanical ConfigurationPressurePort 1/4NPT(standard)*ElectricalConnection 9.4miniDIN,3pinPackard*SealingRating IP65withstandard9.4DINcableWettedParts 316stainlesssteel
Forbestperformance,useshieldedcables.Matingcableassembliessoldseparately.*ConsultfactoryforfurtherOEMoptions.
Electrical Connections
Signal Function Color Pin Electrical Connector
0-5V SupplyV+ Red 1 DIN 4 pin (9.4)
Com Black 2 Output White 3 N/A N/A 4
4-20mA SupplyV Red 1 Output Black 2
0-5V Com - A 3 pin Packard
Supply+ - B Output+ - C
4-20mA Output - A Supply+ - B
12
3
4
A
C
B1 3
4
2
12
3
4
A
C
B1 3
4
2
65mm
25mm
25mm
65mm
36
Features
• Vacuumto10,000PSIrange
• Variousoutputs
• Compactdesign
• 316stainlesssteelwettedparts
• Lowcost
• Better0.4%accuracy
• Customoutputsandrangesavailable
• OEMtestedandapproved
Description
TheNT40SeriesPressureTransducerutilizespiezoresistancetechnologyinanallstainlesssteelbody.Itiscompactinsize,haslongtermstability,iseasytoinstall,andisveryeconomical,aswellasreliable.
TheNT40setsanewprice-performancestandardforlowcost,highvolumecommercialandindustrialapplications.
Application
• Hydraulic/mobilehydraulic
• Pneumaticsystems
• FoodandbeverageIndustry
• Refrigerationsystems
• Pumpsandcompressors
• Energyandwatermanagement
• Constructionand agriculturalequipment
How to Order (Example:PartNumber:NT40-03-B-0500-G-Q00-5)
Model
NT40 – 03 – B - 0500 – G – Q00 – 5
Media Connection
03=1/4"NPTMale**
Output
B=4-20mA
C=0-5V(3wire)**
Pressure Range(PSI)
0015
0025
0050
0100
0250
0500
1000
2500
5000**
Pressure Type
G=Gauge
ElectricalConnection
Q00=M12
D00=9.4miniDIN**
Accuracy
5=0.4%**
**ConsultfactoryforfurtherOEMoptions
Transducers NT40
37
Specifications
InputSupplyVoltage 12-36VDCPressureRange VACto10,000PSIProofPressure 1.5xfullscaleBurstPressure 3xfullscaleFatigueLife Morethan4millioncycles
PerformanceAccuracy 0.4%Stability 0.2%fullscaleCompensatedTemperatures -10to75°C(14to167°F)OperatingTemperatures -20to80°C(-4to176°F)ZeroandSpanOffsetTolerance 1.5%
Mechanical ConfigurationPressurePort 1/4NPT(standard)*ElectricalConnection M12*SealingRating IP67whenusedwithM12cableWettedParts 316stainlesssteel
Forbestperformance,useshieldedcables.Matingcableassembliessoldseparately.*=ConsultfactoryforfurtherOEMoptions
Electrical Connections
NT40 M12 pin assignments
Voltageoutputs 4-20mAoutput
pin1=VoltageSupply+ pin1=VoltageSupply+
pin2=Output pin2=N/C
pin3=Com pin3=Output
pin4=N/C pin4=N/C
12
3
4
A
C
B1 3
4
2
25mm
65mm
Transducers NT40
38
Features• Totallydigitalproprietarydesign
• Innovativeredundantsensingelements
• 24Vdigitaloutputforpressureortempswitchpoint
• Voltageandcurrentoutputs
• CustompressureRangesandoutputsavailable
• Morestandardpressureranges,industryfirst
• Optional4xoverpressure(onmostranges)
• 0.25%accuracy
• ASICtechnology,nozero/spanpotentiometers
• Allstainlesssteelweldedhousing
• IP-69Kratedsealavailable(highpressurewashdown)
• Innovativelowcurrentconsumption,idealforcustomwirelesssolutions
• ProgramablesystemsavailableforOEM/systemsintegratorsforin-house configuringofoutputs,rangesandsetpointstoreduceinventoryandleadtimes
• Calibrationcertificatesavailable(contactcustomerservice)
Description
TheNT25Seriesdigital/configurableisanindustryfirst.Thisindustrialpressuretransducerfeaturesstabilityandaccuracyoverawidetemperaturerange.Itislowerincostthancompetitiveunitstypicallynotfoundinolderanalogdesigns.Itisalsoplugandplay,whichisnotfoundinmostlower-gradecompetitiveunits.
Withitsproprietarydigital/ASICtechnology,theNT25Seriesfeaturesfieldprovenredundantsensingelementswithouttheneedforsolderinresistorsortrimpotsthatcandriftovertime.Thisprovidesyearsofexcellentperformanceandreliabilityevenintheharshestapplications.Thiscombinedwithoptional
4xoverpressureandtheoptionalintegratedtemperatureorpressuredigitalswitchfeature,makestheNT25Seriestrulyanindustryfirstandsecondtonone.
Forextremeapplicationswherepowerwashersareusedforwashdown,theNT25SeriesoptionalIP69Kseal,anotherindustryfirst,makesitidealnomatterwhattheenvironment.
Withitsflexiblelowpowerdesignandlowermanufacturingcosts,theNT25Seriesoffersoutstandingvalueandmakesitidealforcustomwirelessapplications.
How to Order (Example:PartNumber:NT25-03-D-1000-G-Q00-2-T40)
Media Connection03=1/4”NPTMale09=7/16”x20**
OutputB=4-20mAC=0-5vdcD=0-10vdcH=1-5vdcJ=1-6vdcG=0.5-5.5vdc
(voltageoutputsare3wirenon-ratiometric)
Pressure Range(PSI)0015 09000025 10000050 20000100 30000150 40000200 50000250 600003000400050006000700
Pressure Type
G=Gauge
ElectricalConnectionQ00=IP69KM12D00=4pinMini 9.4DIN**
Accuracy
2=0.25%
**ConsultfactoryforfurtherOEMoptions
Model NT25=2XOverPressureNT26=4XOverPressure(upto5000PSI)
Pressure or Temp Set Point % (P or T)X=noSPP or T10=10%P or T20=20%P or T30=30%P or T40=40%P or T50=50%P or T60=60%P or T70=70%P or T80=80%P90=90%(fulltemprangeis10to80°C)**
NT25 – 03 – D – 1000 – G – Q00 – 2 – T40
Transducers NT25
39
Specifications
Performance Performance@25°C(77°F)Accuracy 0.25%BFSL(includes:non-linearity,hysteresisandnon-repeatability)OverangeProtection 2xRatedPressureoroptional4xPressureRange seeorderingchart-upto6000PSI(690bar)(optionalhigherrangesavailable)BurstPressure 5xor20,000PSI,whicheverislessPressureCycles >100millionUpdateTime <=1msecDigitalOutput Optionaldigitaloutputforpressureortempswitchpoint (notavailableon4-20mAoutputunits)Environmental DataTemperatureCompensatedTemperatures -20°to85°C(-4to185°F)OperatingTemperatures -40°to100°C(-40to212°F)Storage -40°to125°C(-40°to250°F)TotalErrorBand(TEB) 0.9%Stability 0.25%FStypical(1year)Shock 100g,6ms,1/2sineperEN60068-2-27,EN60068-2-29Vibration 12gpeak,10to2000HzperEN60068-2-6,EN60068-2-64EMI/RFIProtection YesRating UptoIP-69Kavailable(highpressurewashdown)
Mechanical ConfigurationPressureConnections SeeorderingchartWettedMaterial 17-4PHstainlesssteel(forothermaterialsconsultfactory)ElectricalConnection 9.4Din,IP-69K4pinM12ConnectorCase(housing) 304stainlesssteel
Electrical DataExcitation 3.3-28VDC,Typ(mustbeatleast0.3Vabovefulloutputvoltage) (7.5VDCminfor4-20mA)Output seeorderingchartOutputLoad 0-800Ohms@10-28VDCforcurrentoutput10KOhmsminimum forvoltageoutputsCurrentConsumption 25mAmax(currentoutput),<5mA(voltageoutput) withoutdigitaloutput,<8mAwithdigitaloutputOutputNoise <2mVRMSReversePolarityProtection YesZeroOffset 1%CEApproval Shieldmustbeattachedtoconnectorhousing (nottestedwithcablelengthsover30meters).SetPointforEitherPressureorTemperature Forpressure,thisisdonebyselectingapercentageofyourtransducer’sfull rangeandthiswillbethesetpoint(40%ofa1000PSIrangewillhavetheset pointat400PSI)“P40”.Fortemperature,simplyselectN°C.
2.59 2.78
0.44
M12
0.875 Hex0.875 Hex
0.88
Transducers NT25
AUTHORIZED
[email protected] | AIROYALCOMPANY.NET
NEW JERSEY
43 Newark Way, Maplewood, NJ 07040
973-761-4150 Fax 973-761-5731
PENNSYLVANIA
610-314-5566 Toll Free: 866-247-6645
DELAWARE & MARYLAND
Toll Free: 866-247-6645 Fax 410-235-0011
NEW YORK
306 Commack Rd. Ste. 200, Commack, NY 11725
516-248-4833 Fax 631-499-0119