3 Port Solenoid Valve Rubber Seal Series VZ100/300/500 Series Variations VZ100 VZ300 VZ300 VZ500 VZ500 M5 x 0.8 For N.C. P A: 0.11 A R: 0.19 M5 x 0.8 0.66 2 3 (A R) 2.5 2 3 (A R) 1.2 2 3 (A R) N. C. N. O. 2.7 2 3 (A R) Body Ported Base Mounted Port size Type of actuation Voltage Series Electrical entry With light/surge voltage suppressor (Option) Manual override 1 8 1 8 1 8, 1 4 • Grommet (G) • L plug connector (L) • M plug connector (M) • With surge voltage suppressor (G) (L) (M) (D) • With light/ surge voltage suppressor (L) (M) (D) • DIN terminal (D) • Non-locking push type • Non-locking push type • Locking type (Slotted) • Locking type (Manual) For N.O. R A: 0.19 A P: 0.13 Sonic conductance C [dm 3 /(s·bar)] (Standard) 100 VAC 50/60 Hz 200 VAC 50/60 Hz 24 VDC (Option) 24 VAC 50/60 Hz 48 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 6 VDC 12 VDC 48 VDC 4-6-1 V100 SY SYJ VK VZ VT VP VG VP S070 VQ VKF VQZ VZ VS VFN 1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

3 Port Solenoid Valve Rubber Seal Series VZ100/300/500 · For VZ110 E For VZ120 5L Standard length is 300 mm, but the following lengths are also available. Connector assembly with

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 3 Port Solenoid Valve Rubber Seal Series VZ100/300/500 · For VZ110 E For VZ120 5L Standard length is 300 mm, but the following lengths are also available. Connector assembly with

3 Port Solenoid ValveRubber Seal

Series VZ100/300/500Series Variations

VZ100

VZ300

VZ300

VZ500

VZ500

M5 x 0.8

For N.C.P � A: 0.11

A � R: 0.19

M5 x 0.80.66

2 � 3(A � R)

2.52 � 3

(A � R)

1.22 � 3

(A � R)

N. C. N. O.

2.72 � 3

(A � R)

Bo

dy

Po

rted

Bas

e M

ou

nte

d

Port size Type of actuation

VoltageSeries Electrical entry With light/surge voltage suppressor

(Option)

Manual override

1 8

1 8

1 8, 1 4

• Grommet (G)

• L plug connector (L)

• M plugconnector (M)

• With surgevoltagesuppressor(G) (L)(M) (D)

• With light /surge voltagesuppressor(L) (M)(D)

• DIN terminal (D)

• Non-lockingpush type

• Non-lockingpush type

• Lockingtype(Slotted)

• Lockingtype(Manual)

For N.O.R � A: 0.19

A � P: 0.13

Sonicconductance

C [dm3/(s·bar)]

(Standard)100 VAC 50/60 Hz200 VAC 50/60 Hz24 VDC

(Option)24 VAC 50/60 Hz48 VAC 50/60 Hz

110 VAC 50/60 Hz220 VAC 50/60 Hz

6 VDC12 VDC48 VDC

4-6-1

V100

SY

SYJ

VK

VZ

VT

VP

VG

VP

S070

VQ

VKF

VQZ

VZ

VS

VFN

1

Courtesy of S

teven Engineering, Inc.-230 R

yan Way, S

outh San F

rancisco, CA

94080-6370-Main O

ffice: (650) 588-9200-Outside Local A

rea: (800) 258-9200-ww

w.stevenengineering.com

Page 2: 3 Port Solenoid Valve Rubber Seal Series VZ100/300/500 · For VZ110 E For VZ120 5L Standard length is 300 mm, but the following lengths are also available. Connector assembly with

Manifold Variations

Series VZ100

Series VZ300 Series VZ500

A port size

One-touch fitting

Applicable tubing O.D.Valve series

A portlocation

P/R portsize

M5 x 0.8 � — — — —

� — — — —

ø8ø6ø4

VZ100 Top

M5 1 8

ø ø1 4 5 16ø " " "5 32

Bo

dy

Po

rted

Bas

e M

ou

nte

d

� — — — —

— — — —

— � — — —

VZ300 Top

VZ500 Top

1 8

1 8

1 8

1 4

� � — — —

— —�Note)

�Note)

— —

� �� � —VZ300

Bottom

Side

VZ500 Bottom

1 8

1 8

— —� — —1 4

— —� � �

— — —

— — —

— — —

— — —

— — —

— — —

— — —

� � —

— — —— � �Side 1 4

Note) Internal pilot

Series VZ100/300/500

4-6-2

2

Courtesy of S

teven Engineering, Inc.-230 R

yan Way, S

outh San F

rancisco, CA

94080-6370-Main O

ffice: (650) 588-9200-Outside Local A

rea: (800) 258-9200-ww

w.stevenengineering.com

Page 3: 3 Port Solenoid Valve Rubber Seal Series VZ100/300/500 · For VZ110 E For VZ120 5L Standard length is 300 mm, but the following lengths are also available. Connector assembly with

Warning• Manual override is available in 2 types, non-locking push type and

locking type.(Locking type is for VZ300/500 only.)

During manual operation, the equipment that is connected will operate. Therefore, make sure there are no hazardous conditions before operation.

In the case of DC wiring, be sure to connect in line with the polarity indication (positive [+]/negative [–]) on the connector. When the lead wire is pre-wired, positive [+] is red and negative [–] is black respectively.

� Non-locking push type must be pressed in the direction of the arrow.

Nil: Non-locking type B: Locking type B (Slotted)

C: Locking type C (Manual)

When operating the locking type manually, apply torque of 0.2 N·m or less.

CautionLight /Surge Voltage Suppressor

Grommet Type

L/M Plug Connector TypeAC

DC

With indicator light (AC)

With indicator light (DC)

AC

DC

With indicator light (AC)

With indicator light (DC)

AC DC

∗ Markings

DIN Terminal Type

In the case of DC wiring, connect terminal no.1 of the connector to the positive [+] side, and terminal no. 2 to the negative [–] side. (Refer to the markings on the terminal block.)

Common Exhaust Type for Main and Pilot

How to Use Plug ConnectorAttaching and detaching connectors1. To attach a connector, hold the lever and connector unit between your

fingers and insert straight onto the pins of the solenoid valve so that the lever’s pawl is pushed into the groove and locks.

2. To detach a connector, remove the pawl from the groove by pushing the lever downward with your thumb, and pull the connector straight out.

Exhaust air from the pilot valve will flow to the main valve exhaust port.• For use in an environment in which exhaust from the pilot valve is

undesirable.• For use when the intrusion of dust from the surroundings must be

prevented. Also, make sure the piping will not restrict the flow from the exhaust port.

VZ3� M, VZ5� M24

24

Crimping of lead wires and socketsPeel 3.2 to 3.7 mm of the tip of lead wire, enter the core wires neatly into a socket and crimp it with a special crimp tool. Be careful so that the cover of lead wire does not enter into the crimping area.(For special crimping tool, please contact SMC.)

PrecautionsBe sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page 4-18-2.

Manual Override Operation

Coi

l

Coi

l

Coi

lC

oil

Coi

l

Black

Red

Dio

de

AC

DC

Coi

lC

oil

Black

Red

Dio

de

Coi

lC

oil

Coi

l

Dio

deD

iode

Neon bulb

Neon bulb

Marking ∗ Light(Built-in

connector)

Surge voltagesuppressor(Built-interminal block)

Molded coil

GroovePin

Pin

Type L

Type M

Connector

Lever

DC polarityindicator

DC coil: + Red, – Black

Lead wire

Socket part no. DXT170-71-1

Cover

Cover

Terminal

Hook

Core wirecrimping area Crimping

area

Core wire

Lead wire

Insulation ( )0.2 to 0.33 mm2

Max. cover dia.:ø1.7 mm

4-6-3

Series VZ100/300/500

V100

SY

SYJ

VK

VZ

VT

VP

VG

VP

S070

VQ

VKF

VQZ

VZ

VS

VFN

3

Courtesy of S

teven Engineering, Inc.-230 R

yan Way, S

outh San F

rancisco, CA

94080-6370-Main O

ffice: (650) 588-9200-Outside Local A

rea: (800) 258-9200-ww

w.stevenengineering.com

Page 4: 3 Port Solenoid Valve Rubber Seal Series VZ100/300/500 · For VZ110 E For VZ120 5L Standard length is 300 mm, but the following lengths are also available. Connector assembly with

How to OrderInclude the connector assembly part number together with the part number for the plug connector’s solenoid valve without connector.(Example) 2000 mm lead wire length.

Lead wire color

Symbol

Blue (2)Red (2)Gray (2)

Red: +, Black: –

Note

Nil

1234

Socket only(2 pcs.)

Withoutlead wire

For 100 VACFor 200 VACAnother VAC

For DC

Lead wire length

Nil6

1015202530

300600

10001500200025003000

Symbol

200025003000

Lead wirewith socket

Lead wire lengthL mm

How to Calculate the Flow Rate

Electrical entryGHL

LNL plug

connector

M plugconnector

DIN terminal

LOM

MN

Grommet (Lead wire: 300 mm)Grommet (Lead wire: 600 mm)

With lead wireWithout lead wireWithout connector

With lead wireWithout lead wireWithout connectorMO

D With connectorWithout connectorDO

For obtaining the flow rate, refer to page 4-1-6.

Lead wire length

Nil6

1015

300600

10001500

Symbol SymbolLead wire length L mm Lead wire length L mm

202530

CDXT170

∗ Indicator light is not available for grommet type.Coil rated voltage

Applicable model

C

A

For Series VZ300/500

For VZ110

E For VZ120

5 L

Standard length is 300 mm, but the following lengths are also available.

Connector assembly with protective cover enhances dust protection.• Effective to prevent short circuit accidents due to penetration of foreign

matter into the connector section.• The material of cover is chloroprene rubber for electricity which is

excellent in weathering and electrical insulating properties. But don’t splash with cutting oil.

• Simple and unencumbered appearance by adopting round-shaped cord.

Dimensions: Connector Assembly with Cover

80 ADXT170

123 ADXT170

How to Order Connector Assembly

How to Order

How to Order Solenoid Assembly

CautionPlug Connector Lead Wire LengthAttaching and Detaching Lead Wires with Sockets

Connector Assembly with Protective Cover

1. AttachingInsert the sockets into the square holes of the connector (with + and – indication) and, continue to push the sockets all the way in until the lock by hooking into the seats in the connector. (When they are pushed in, their hooks open and they are locked automatically.) Then confirm that they are locked by pulling lightly on the lead wires.

2. DetachingTo detach a socket from a connector, pull out the lead wire while pressing the socket’s hook with a stick having a thin tip (approx. 1 mm). If the socket will be used again, first spread the hook outward.

DIN Terminal Part No.

Connection1. Loosen the set screw and pull out the connector from the terminal block

of the solenoid.2. Pull out screw and insert a screwdriver to the slit area near the bottom

of terminal block to separate block and housing.3. Loosen the terminal screws (slotted screws) on the terminal block,

insert the core of the lead wire into the terminal in accordance with the prescribed connection method, and attach securely with the terminal screws.

4. Tighten the ground nut to secure the wire.Change of electrical entry (Orientation)

After separating terminal block and housing, the cord entry direction can be changed by attaching the housing in the desired direction (4 directions in 90° increments).∗ In the case of w/ indicator light, avoid damaging the indicator light with

lead wire.Precautions

Plug a connector in or out vertically, never at an angle.Applicable cable

O.D.: ø3.5 to ø7(Reference) 0.5 mm2 2 core and 3 core wires equivalent to JIS C 3306.

Connector with Light Circuit

Without indicator light DXT170-176-1

Part no.DXT170-176-2-01DXT170-176-2-02DXT170-176-2-03DXT170-176-2-04DXT170-176-2-07DXT170-176-3-51DXT170-176-3-06DXT170-176-3-05DXT170-176-3-53

Rated voltage Voltage symbol

100V200V110V220V240V6VD12VD24VD48VD

100 VAC200 VAC110 VAC220 VAC240 VAC

6 VDC12 VDC24 VDC48 VDC

With Indicator Light

How to Use DIN Terminal

AC circuit diagram

NL: Neon bulbR: Resistor

DC circuit diagram

D: Protective diodeLED: Emitting diode

R: Resistor

123∗

4∗

56∗

9∗

100 VAC, 50/60 Hz200 VAC, 50/60 Hz110 VAC, 50/60 Hz220 VAC, 50/60 Hz24 VDC12 VDC

Other∗ Option

Light/Surgevoltage suppressor

Nil NoneZ∗

SWith light/surge voltage suppressorWith surge voltage suppressor

Polarity indicator

SocketHook

Connector

Lead wire

Washer

Grommet(Rubber)

(Voltage symbol)Refer to the table below.

Terminal screw(3 locations)

Tightening torque0.2 to 0.25 N·m

Holding screwtightening torque0.3 to 0.4 N·m

Housing

(Position forlight mounting)

Terminal blockSlot area

Ground nuttightening torque

1.65 to 2.5 N·m

Red Black Black

VZ312-5M0-M5·········2 pcs.DXT170-80-4A-20·····2 pcs.

Series VZ100/300/500

4-6-4

4

Courtesy of S

teven Engineering, Inc.-230 R

yan Way, S

outh San F

rancisco, CA

94080-6370-Main O

ffice: (650) 588-9200-Outside Local A

rea: (800) 258-9200-ww

w.stevenengineering.com

Page 5: 3 Port Solenoid Valve Rubber Seal Series VZ100/300/500 · For VZ110 E For VZ120 5L Standard length is 300 mm, but the following lengths are also available. Connector assembly with

How to Order

3 Port Solenoid ValveRubber Seal, Body Ported

Series VZ100

Rated voltage123∗

4∗

56∗

9∗

100 VAC, 50/60 Hz200 VAC, 50/60 Hz110 VAC, 50/60 Hz220 VAC, 50/60 Hz24 VDC12 VDC

Other∗ Option

∗ “LN”, “MN” type: With 2 sockets.

∗ Not available for “GZ”, “HZ” and “DOZ”

Light/Surge voltage suppressorNilZ∗

SWith light/surge voltage suppressor

With surge voltage suppressor

F: With foot bracket

L: With lead wire (Length 300 mm)

M: With leadwire (Length300 mm)

MN: Withoutlead wire

D: With connector

LN: Withoutlead wire

LO: Withoutconnector

MO: Withoutconnector

DO: Withoutconnector

G: Lead wirelength300 mm

H: Lead wirelength600 mm

For details about certified products conforming to international standards, visit us at www.smcworld.com.

Body ported VZ1

Type of actuation

1

Normally closed

2

Normally open

Grommet L plug connector M plug connector DIN terminal

Electrical entry

None

Port size

Option

M5Ty

pe o

f actu

ation

Rated

volta

ge

Electri

cal e

ntry

Light

/Sur

ge vo

ltage

supp

ress

or

Option

Port s

ize

Note) Bracket is not mounted.

Regarding VZ120, R port is a supply port.

1 5 L

M5 M5 x 0.8

0

4-6-5

V100

SY

SYJ

VK

VZ

VT

VP

VG

VP

S070

VQ

VKF

VQZ

VZ

VS

VFN

5

Courtesy of S

teven Engineering, Inc.-230 R

yan Way, S

outh San F

rancisco, CA

94080-6370-Main O

ffice: (650) 588-9200-Outside Local A

rea: (800) 258-9200-ww

w.stevenengineering.com

Page 6: 3 Port Solenoid Valve Rubber Seal Series VZ100/300/500 · For VZ110 E For VZ120 5L Standard length is 300 mm, but the following lengths are also available. Connector assembly with

Construction

Made to Order Specifications(For details, refer to page 4-6-46.)

100, 200, 24∗, 48∗, 110∗, 220∗24, 6∗, 12∗, 48∗

–15 to +10% of rated voltage

Note) At rated voltage

Inrush 4.5/50 Hz, 4.2/60 Hz100 VAC: 45/50 Hz, 42/60 Hz200 VAC: 22.5/50 Hz, 21/60 Hz

3.5/50 Hz, 3/60 Hz100 VAC: 35/50 Hz, 30/60 Hz200 VAC: 17.5/50 Hz, 15/60 Hz

∗ Option

Low power consumption: 1.8 W DC

Applicable for vacuum use –100 kPa

SpecificationsFluid

Ambient and fluid temperature (°C)Response time (ms) (1)

Manual overrideLubricationMounting orientationShock/Vibration resistance (m/s2) (2)

Enclosure

Air

–10 to 50 (No freezing. Refer to page 4-18-4.)Operating pressure range Refer to the table below.

15 or less

Non-locking push typeFlow Characteristics Refer to the table below.Max. operating frequency (Hz) 15

Not requiredUnrestricted

300/50Dustproof

Note 1) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature: 20°C, at rated voltage, without surge suppressor)

Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period)

Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 1000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period)

Operating Pressure

Description

With foot bracket

Silencer M5

Part no.

DXT170-34-1A

AN120-M5(ø8 x 17l )

NoteMounting screw

(M3 x 6)For valve unit (R port),

Noise reduction: 21 dB or more, Effective area 5 mm2 Model

Bodyported

VZ110VZ120

Type of actuation

N.C.N.O.

Operating pressure range(MPa)

0 to 0.7

M5 x 0.8

0 to 0.5

Vacuum specifications (MPa)1 (P) port R port

–27 kPa to 0.6–100 kPa to 0

–100 kPa to 0–100 kPa to 0.4

Port size

M5 x 0.8

Weight (g)

70

Model

Bodyported

VZ110VZ120

Type of actuation

N.C. 0.110.19

0.0260.071

0.0230.042

0.190.13

0.0710.18

0.0420.031N.O.

Portsize

Flow characteristics

Supply side Exhaust side

C [dm3/(s·bar)] C [dm3/(s·bar)]b Cv b Cv

Note ) Weight stands for grommet type

N.C.: 1 � 2 (P � A)N.O.: 3 � 2 (R � A)

N.C.: 2 � 3 (A � R)N.O.: 2 � 1(A � P)

Option

VZ110 (N.C.) JIS Symbol JIS Symbol

De-energized De-energized

No. DescriptionSolenoidassembly

Solenoidassembly

O-ring

Part no.

DXT170-A-���

DXT170-E-���

13 x 11 x 1

MaterialEpoxy

Stainless steel

EpoxyStainless steel

NBR

Note

VZ110

VZ120

No. DescriptionBodyPush rodEXH poppet

N.C.N.O.

Back up springPoppet spring

MaterialZDCResinNBR

Stainlesssteel

NotePlatinum silver

VZ120 (N.O.)

Replacement Parts

Component Parts

For manifold use, refer to the pages 4-6-8 to 4-6-11.

Flow Characteristics

Solenoid Specifications

Electrical entry

Coil rated voltage (V)

Allowable voltage fluctuation (%)

Power consumption (W) Note)

[Current mA]

Apparent power (VA)[Current mA]

Surge voltage suppressorIndicator light

AC50/60 HzDC

DC

ACHolding

Grommet (G)/(H), L plug connector (L),M plug connector (M), DIN terminal (D)

1.8 (With indicator light 2.1) [24 VDC: 75 (With indicator light 87.5)]

DC: Diode, AC: ZNRDC: LED (Red), AC: Neon bulb

Note)

w

e

q

r

uCommon with Series VZ 003

5

t

y1(P) (SUP port)

3(R) (EXH port)

1(P) (EXH port)

3(R) (SUP port)

Note)

Series VZ100

4-6-6

6

Courtesy of S

teven Engineering, Inc.-230 R

yan Way, S

outh San F

rancisco, CA

94080-6370-Main O

ffice: (650) 588-9200-Outside Local A

rea: (800) 258-9200-ww

w.stevenengineering.com

Page 7: 3 Port Solenoid Valve Rubber Seal Series VZ100/300/500 · For VZ110 E For VZ120 5L Standard length is 300 mm, but the following lengths are also available. Connector assembly with

Body Ported

�: With light /surge voltage suppressor

Grommet (G), (H)VZ1�0-� �-M5(-F)G

H

L plug connector (L)VZ1�0-�L�-M5

M plug connector (M)VZ1�0-�M�-M5

DIN terminal (D)VZ1�0-�D�-M5

(Mounting hole)

(Lead wire length)

(Lead wire length)

G: 300 mmH: 600 mm

Manual override(Non-locking)

(Mounting hole for manifold)

2-M3 x 0.5 depth 5(Mounting thread)

≅300

(Lea

d w

ire le

ngth

)

≅300

Applicable cable O.D.: ø3.5 to ø7

(Piping port)

4-6-7

Series VZ1003 Port Solenoid ValveRubber Seal, Body Ported

V100

SY

SYJ

VK

VZ

VT

VP

VG

VP

S070

VQ

VKF

VQZ

VZ

VS

VFN

7

Courtesy of S

teven Engineering, Inc.-230 R

yan Way, S

outh San F

rancisco, CA

94080-6370-Main O

ffice: (650) 588-9200-Outside Local A

rea: (800) 258-9200-ww

w.stevenengineering.com

Page 8: 3 Port Solenoid Valve Rubber Seal Series VZ100/300/500 · For VZ110 E For VZ120 5L Standard length is 300 mm, but the following lengths are also available. Connector assembly with

Blanking Plate Assembly

Option

Series VZ100Manifold Specifications

How to Order ManifoldInstruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no. (Example) VV3Z1-01-031··········1 pc. (Manifold base)

∗VZ110-5LZ-M5·······2 pcs. (Valve)∗DXT170-25-1A·······1 pc. (Blanking plate assembly)

The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

Manifold SpecificationsModel

Manifold type Single base/B mountVV3Z1-01-�1 VV4Z1-20-�1

P(SUP)/R(EXH) Common SUP/Common EXHValve stations 2 to 20 stations (1)

A portPorting specifications

LocationDirection

1(P), 3(R) port2(A) port

ValveTop

Port sizeM5 x 0.8

M5 x 0.8 Rc 1 8

Note 1) If there are more than 10 stations, exhaust from both sides of manifold.Note 2) Not able to use VZ120 and VZ110 on the same manifold base.Note 3) In the case of VZ120, supply air to 3 (R) port and exhaust from 1(P) port.

Applicable baseVV3Z1-01-�1VV4Z1-20-�1

Manifoldbase

Manifoldbase

Applicable baseVV3Z1-01-�1VV4Z1-20-�1

Manifoldbase

Applicable baseVV3Z1-01-�1VV4Z1-20-�1

Manifoldbase

Applicable baseVV3Z1-01-�1VV4Z1-20-�1

Flow Characteristics

ManifoldPort size

Flow characteristics

VV3Z1-01-�1VV4Z1-20-�1

1(P), 3(R)Port

M5 x 0.8 M5 x 0.8 0.130.13

0.130.1

0.030.03

0.220.22

0.0740.15

0.0480.052M5 x 0.8

A, BPort

1 � 2 (P � A) 2 � 3 (A � R)

b Cv b Cv

1/8

When mounting a solenoid valve on the manifold base or sub-plate, etc., the mounting direction is determined. If mounted in the wrong direction, the equipment to be wired might result in malfunction. Refer to dimensions of this catalog and use caution to the mounting direction.

C[dm3/(s·bar)]

C[dm3/(s·bar)]

Combinations of Solenoid Valve, Gasket and Manifold

Individual EXH Spacer Assembly Individual SUP Spacer Assembly

DXT170-25-1A

DXT170-44-1ADXT170-48-1A

Warning

Mounting ScrewTightening Torques

M2.5: 0.45 N·m

Caution

Round head combination screwM2.5 x 25(With spring washer) Round head

combination screw

Round headcombination screw

Round head combination screw

(With spring washer)

Blanking plate

Manifold gasket

Manifold gasket

Spring washerSpring washer

Individual EXH spacer

Manifold gasket

IndividualSUP spacer

4-6-8

8

Courtesy of S

teven Engineering, Inc.-230 R

yan Way, S

outh San F

rancisco, CA

94080-6370-Main O

ffice: (650) 588-9200-Outside Local A

rea: (800) 258-9200-ww

w.stevenengineering.com

Page 9: 3 Port Solenoid Valve Rubber Seal Series VZ100/300/500 · For VZ110 E For VZ120 5L Standard length is 300 mm, but the following lengths are also available. Connector assembly with

RcG

NPT

Nil

00NNPTF00T

00F

Thread type···

···

2 stations

20 stations

02

20

···

···

2 stations

20 stations

02

20

StationsOption

VV3Z1 0501 1

∗ Bracket is not mounted.

F: With footbracket

Option

∗ Bracket is not mounted.

F: With footbracket

Note) • If there are more than 10 stations, exhaust from both sides of manifold.

• It is not able to use VZ110 and VZ120 on the same manifold base.

Applicable solenoid valve VZ110-���-M5 VZ120-���-M5Applicable blanking plate assembly DXT170-25-1AIndividual EXH spacer assembly DXT170-48-1AIndividual SUP spacer assembly DXT170-44-1A

Stations

VV4Z1 0520 1

Note) • If there are more than 10 stations, supply air to SUP port on both sides of the manifold and exhaust from EXH port on both sides of the manifold.

• It is not able to use VZ110 and VZ120 on the same manifold base.

Applicable solenoid valve VZ110-���-M5 VZ120-���-M5Applicable blanking plate assembly DXT170-25-1AIndividual EXH Spacer assembly DXT170-48-1AIndividual SUP Spacer assembly DXT170-44-1A

Type 01 How to Order

Type 20 How to Order

P port

A port

R port

A port

P port

R port

Rc

Rc

4-6-9

Series VZ1003 Port Solenoid ValveRubber Seal, Body Ported

V100

SY

SYJ

VK

VZ

VT

VP

VG

VP

S070

VQ

VKF

VQZ

VZ

VS

VFN

9

Courtesy of S

teven Engineering, Inc.-230 R

yan Way, S

outh San F

rancisco, CA

94080-6370-Main O

ffice: (650) 588-9200-Outside Local A

rea: (800) 258-9200-ww

w.stevenengineering.com

Page 10: 3 Port Solenoid Valve Rubber Seal Series VZ100/300/500 · For VZ110 E For VZ120 5L Standard length is 300 mm, but the following lengths are also available. Connector assembly with

Type 01 Manifold: Top Ported

�: With light /surge voltage suppressor

VV3Z-01- Stations 1(-F)Grommet (G), (H)

L plug connector (L) DIN terminal (D)M plug connector (M)

Stations nL1

L2

24840

36456

48072

59688

6112104

7128120

8144136

9160152

10176168

11192184

12208200

13224216

14241232

15256248

16272264

17288280

18304296

19320312

20336328

L3 16 32 48 64 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304L4 8 24 40 56 72 88 104 120 136 152 168 184 200 216 232 248 264 280 296

Applicable cable O.D.: ø3.5 to ø7

(Mounting hole)

(Mounting hole)

(Pitch)

Manual override(Non-locking)

A port

G: 300 mmH: 600 mm (Lead wire length)

(P, R port)

4-M3 x 0.5 depth 4.5(Bracket mounting screw)

≅300

(Lead wire length)

≅300

(Lea

d w

ire le

ngth

)

Series VZ100

4-6-10

10

Courtesy of S

teven Engineering, Inc.-230 R

yan Way, S

outh San F

rancisco, CA

94080-6370-Main O

ffice: (650) 588-9200-Outside Local A

rea: (800) 258-9200-ww

w.stevenengineering.com

Page 11: 3 Port Solenoid Valve Rubber Seal Series VZ100/300/500 · For VZ110 E For VZ120 5L Standard length is 300 mm, but the following lengths are also available. Connector assembly with

Type 20 Manifold: Top Ported

�: With light /surge voltage suppressor

VV4Z1-20- Stations 1(-F)Grommet (G), (H)

L plug connector (L) DIN terminal (D)M plug connector (M)

Stations nL1

L2

25340

36956

48572

5101

88

6117104

7133120

8149136

9165152

10181168

11197184

12213200

13229216

14245232

15261248

16277264

17293280

18309296

19325312

20341328

L3 16 32 48 64 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304L4 8 24 40 56 72 88 104 120 136 152 168 184 200 216 232 248 264 280 296

Applicable cable O.D.: ø3.5 to ø7

(Mounting hole)

(Mounting hole) (Pitch)

Manual override(Non-locking)

A port

G: 300 mmH: 600 mm (Lead wire length)

4-M3 x 0.5 depth 4.5

(Bracket mounting screw)

≅300

(Lead wire length)

≅300

(Lea

d w

ire le

ngth

)

(P, R port)

4-6-11

Series VZ1003 Port Solenoid ValveRubber Seal, Body Ported

V100

SY

SYJ

VK

VZ

VT

VP

VG

VP

S070

VQ

VKF

VQZ

VZ

VS

VFN

11

Courtesy of S

teven Engineering, Inc.-230 R

yan Way, S

outh San F

rancisco, CA

94080-6370-Main O

ffice: (650) 588-9200-Outside Local A

rea: (800) 258-9200-ww

w.stevenengineering.com

Page 12: 3 Port Solenoid Valve Rubber Seal Series VZ100/300/500 · For VZ110 E For VZ120 5L Standard length is 300 mm, but the following lengths are also available. Connector assembly with

4-6-12

12

Courtesy of S

teven Engineering, Inc.-230 R

yan Way, S

outh San F

rancisco, CA

94080-6370-Main O

ffice: (650) 588-9200-Outside Local A

rea: (800) 258-9200-ww

w.stevenengineering.com

Page 13: 3 Port Solenoid Valve Rubber Seal Series VZ100/300/500 · For VZ110 E For VZ120 5L Standard length is 300 mm, but the following lengths are also available. Connector assembly with

1. Solenoid Valve: Opposite Mounting of Solenoid Assembly 2. Solenoid Valve: External Pilot Specifications

Applicable solenoid valve seriesVZ100/300/500

Model no.

Dimensions: VZ110-�G-M5-X1

Dimensions: VZ312R-�G-M5-X20

Series VZ Made to Order Specifications:

VZ 35 X1( )

VZ1 0 X1( )

Entry is the same as standard products.

� Applicable for individual use of body ported external pilot type

Applicable solenoid valve seriesVZ300/500

Model no.

VZ 35 2R X20( )

Entry is the same as standard products.

SpecificationsOperating pressurerange (MPa)

Main pressureExternal pilot pressure

Pilot exhaust method

–100 kPa to 0.70.15 to 0.7

Pilot valve individual exhaust

DimensionsVZ300: 8 mm longer in total lengthVZ500: 8 mm longer in total length

Manual override(Non-locking)

Manual override(Non-locking)

(External pilot port)

PE port M5 x 0.8

4-6-46

46