1
A A C C E E G G H H 2 2 3 3 6 6 8 8 4 4 5 5 7 7 B B D D F F RTU7 UH4 WH WS RTU8 AC1 SALES 102 CORRIDOR 201 STAIR S-1 SERVER ROOM 204 OFFICE 203 FEMALE 206 MALE 205 CORR. 202 STAFF ROOM 207 OFFICE 208 COMPRESSOR ROOM 210 MECHANICAL 211 OFFICE 212 OFFICE 213 OFFICE 214 OFFICE 215 CORRIDOR 209 STAIR S-2 13 14 10 R 9 19 19 12 13 19 25 19 CO FD CO WC WC V V DS 21 50 75 1 5 FD 75 75 75 50 32 38 32 38 75 13 13 13 13 19 19 19 13 75 19 17 15 15 15 15 19 38 32 19 19 19 2 R 19 19 19 32 10 32 10 9 13 38 32 19 13 18 13 25 2 2 11 16 11 19 13 25 19 13 19 H H 8 8 WH WS COMPRESSOR ROOM 210 MECHANICAL 211 UH4 OFFICE 212 7 R 9 13 19 PD CO PD 20 PD R 9 8 10 19 RP HRT ET 3 3 3 3 4 SENTINEL POLISHER 4 RO PRODUCTION CABINET 4 RO STORAGE TANK 4 4 POST CARBON FILTER 4 UV 4 UV 4 20" FOOD GRADE POLYPHOSPHATE FILTER 4 CARBON BACKWASH FILTER 4 MAINLINE FILTER 5 FD 10 38 13 32 19 32 32 75 75 75 1 75 75 19 19 19 75 38 38 10 10 38 38 32 25 75 25 25 32 32 10 38 6 10 25 25 25 19 19 19 19 32 19 19 38 32 19 A0 ( 841 x 1189 ) 15 10 5 0 10 20 30 40 50 60 DRAWN : CHECKED : DRAWING NAME : PROJECT NUMBER : PROJECT NAME : REVISIONS : NO. DESCRIPTION : DATE : YYYY-MM-DD All drawings and specifications are the property of aodbt and/or their subconsultants and may be reproduced only with their written permission. Information shown herein is for the use on this project only. Contractor shall verify and be responsible for site dimensions and conditions, and inform consultant of any variations that may occur. Dimensional text shall govern over any scaled dimensions. STAMPS : www.aodbt.com 202 - 21 11th St E Prince Albert, SK S6H 0Z8 306.922.5101 235 Ave D North Saskatoon, SK S7L 1M7 306.244.5101 architecture + interior design CIVIL ENGINEER STRUCTURAL ENGINEER MECHANICAL ENGINEER ELECTRICAL ENGINEER CLIENT FEDERATED CO-OPERATIVES LIMITED DATE : PROJECT #: 4933 M:\Current Projects\4933 Flin Flon Co-op\4933 DRAWINGS\4933 WORKING DRAWINGS\4933-MECH Flin Flon Co-op-V16.rvt 14/10/2016 4:12:25 PM GAS SMH 16.067 North of 53 Consumers CO-OP Flin Flon Food Store 100 PTH 10A, Flin Flon, Manitoba M3.3 MEZZANINE PLUMBING PLAN 2016/10/14 1. ALL PLUMBING LINES SHOWN SCHEMATICALLY. 2. ALL WATER PIPING TO RUN CONCEALED IN FINISHED AREAS WITHIN CEILING SPACE AND WALLS. PAINT ALL EXPOSED PIPING AS PER ARCHITECTURAL. ALL SEWER LINES TO RUN CONCEALED BELOW CONCRETE SLAB, WITHIN CEILING SPACE, AND/OR IN WALLS. 3. ALL WATER LINES TO BE COVERED WITH 25mm (1") INSULATION AND WITH PVC JACKET IN EXPOSED AREAS. 4. ALL EQUIPMENT TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. 5. ALL PIPING TO FIXTURES AND EQUIPMENT TO RUN CONCEALED WHERE POSSIBLE. 6. ALL WATER CONNECTIONS TO FIXTURES TO BE 13mm (½") UNLESS OTHERWISE SPECIFIED. 7. CONTRACTOR TO SUPPLY AND INSTALL PLUMBING VENTS, TRAP SEAL PRIMERS, CLEANOUTS, AND ISOLATION VALVES AS PER CODE. 8. INSTALL ALL GAS FIRED EQUIPMENT AND PIPING IN ACCORDANCE WITH THE CANADIAN GAS CODE AND GAS UTILITY REQUIREMENTS. 9. SOLDERS AND FLUXES HAVING A LEAD CONTENT IN EXCESS OF 0.2% SHALL NOT BE USED. 10. PVC AND PLASTIC PIPING MAY BE USED WHERE PERMITTED BY CODE. ALL PVC PIPING WITHIN RETURN AIR CEILING PLENUMS TO BE XFR RATED. 11. ALL PLUMBING TO BE INSTALLED IN ACCORDANCE WITH THE CANADIAN PLUMBING CODE, PROVINCIAL PLUMBING CODES, AND CITY BYLAWS. 12. PROVIDE FIRESTOPS AT ALL PIPING THAT PASSES THROUGH FIRE SEPARATIONS. 13. PLUMBING CONTRACTOR TO CONNECT CONDENSATE DRAINS FROM ALL REFRIGERATED DISPLAY CASES, COOLER, AND FREEZERS TO PIPE DRAINS. CO-ORDINATE WITH REFRIGERATION CONTRACTOR. SEE REFRIGERATION DRAWINGS FOR CONDENSATE DRAIN PLAN. 14. PAINT EXPOSED CONDENSATE LINES IN AND OUT OF FREEZERS, COOLERS AND MEAT PREP AREA TO MATCH WALLS. 15. PROVIDE A COPY OF PLUMBING AND GAS PERMITS TO OWNER. 16. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS THAT ARE NOT ACCESSIBLE OR DIFFICULT TO SERVICE. PROVIDE A MANIFOLD, MANUAL VALVES, AND APPROPRIATE UNDERSLAB " TUBING TO SERVE TRAP PRIMERS. TRAP PRIMERS ARE NOT REQUIRED FOR PIPE DRAINS WHICH ARE USED TO DRAIN CONDENSATE FROM REFRIGERATION CASES AND EVAPORATOR COILS. 17. ALL NEW FLOOR DRAINS FOR REFRIGERATED WALK IN BOXES AND REFRIGERATION CASES SHALL HAVE DEEP SEAL TRAPS. 18. PIPE DRAIN DIMENSIONS SHOWN ARE FOR REFERENCE ONLY. PIPE DRAINS MUST NOT BE VISIBLE FROM FRONT OF REFRIGERATED CASES ON SALES FLOOR AND MUST BE COMPLETELY CONCEALED BENEATH DISLAY CASE, BEHIND KICKPLATES. COORDINATE WITH REFRIGERATION CONTRACTOR. 19. ALL PIPE DRAIN DIMENSIONS SHOWN ARE FOR REFERENCE ONLY. ALL PIPE DRAINS AT FREEZERS AND COOLERS FOR CONDENSATE MUST BE INSTALLED AS CLOSE AS POSSIBLE TO FREEZER AND COOLER WALLS. CO-ORDINATE WITH GENERAL CONTRACTOR AND REFRIGERATION CONTRACTOR. CONTRACTOR WILL BE RESPONSIBLE TO RELOCATE PIPE DRAINS AT THEIR OWN COST IF IT IS DETERMINED THAT THE PIPE DRAINS ARE TOO FAR AWAY FROM FREEZER/ COOLER WALLS CAUSING TRIPPING HAZARDS IN TRAFFIC AREAS. 20. PROVIDE TRUEBRO PREFABRICATED INSULATION PACKAGE OVER ALL EXPOSED WATER SUPPLIES AND WASTES AT BARRIER FREE SINKS DESIGNATED AS "HV". 21. DRAIN LINES WITHIN WALK-IN FREEZER AND COOLERS TO BE INSTALLED TIGHT ALONG INTERIOR COOLER WALLS @ A 1% SLOPE. 22. WATER LINES TO PLUMBING FIXTURES IN MEAT PREP AREA TO BE INSTALLED EXPOSED ON WAREHOUSE SIDE OF COOLER PANELS AND NOT CONCEALED WITHIN COOLER PANEL WALLS. 23. NOTE ALL PENETRATIONS THRU ROOF TO BE SEALED WITH PITCH BOXES. SEE DETAIL 14/M5.1. 24. PROVIDE ISOLATION VALVES ON THE WATER SUPPLY LINES TO ALL PLUMBING FIXTURES INCLUDING PRODUCTION SINKS, JANITOR MOP SINK, ICE MACHINE, PROOFER, ETC. 25. COORDINATE LOCATION OF ALL PLUMBING LINES WITH REFRIGERATION SO AS TO PREVENT LOCATION CONFLICTS. REFRIGERATION LINES TO TAKE PRIORITY. 26. EXPOSED WATER SUPPLIES AT WATER CLOSETS TO BE CHROME. NO EXPOSED PLASTIC PIPING PERMITTED. 75mmØ SANITARY SEWER LINE UP FROM BELOW SLAB CONCEALED IN WALL AND INTO MAIN FLOOR CEILING SPACE. SEE MAIN FLOOR SEWER PLAN 1/M3.1 FOR CONTINUATION. SEE MAIN FLOOR WATER & PROPANE PLAN 1/M3.2 FOR CONTINUATION OF WATER SUPPLY LINES UP HIGH AT U/S OF WAREHOUSE ROOF STRUCTURE/WITHIN BAKERY/DELI CEILING SPACE. SEE WATER HEATER PIPING DETAIL 3/M3.3 FOR PIPING SCHEMATIC OF HEAT RECLAIM TANK 'HRT', WATER HEATER 'WH', POTABLE WATER EXPANSION TANK 'ET', AND HOT WATER RECIRC PUMP 'RP'. SEE WATER TREATMENT SYSTEM PIPING SCHEMATIC 16/M5.1 FOR CONNECTION OF WATER TREATMENT EQUIPMENT. 75mmØ PLUMBING VENT UP FROM MAIN FLOOR CONCEALED IN WALL AND THRU ROOF. FLASH AND SEAL AT ROOF PENETRATION WEATHER TIGHT. PROVIDE THALER #SJ-26 INSULATED ALUMINUM STACK JACK WITH REMOVABLE COVER. SEE MAIN FLOOR SEWER PLAN 1/M3.1 FOR CONTINUATION. SEE MAIN FLOOR WATER & PROPANE PLAN 1/M3.2 FOR CONTINUATION OF 38mm HARD COLD WATER LINE UP FROM LOWER MAIN FLOOR CONCEALED WITHIN WALL TO U/S OF ROOF. 19mm PROPANE LINE DOWN THROUGH ROOF TO UNIT HEATER 'UH4'. FLASH AND SEAL AT ROOF PENETRATION WEATHER TIGHT. TRANSITION LINE TO 13mm ONCE INSIDE BUILDING. SEE DETAIL 14/M5.1. 19mm PROPANE LINE DOWN THROUGH ROOF TO GAS-FIRED WATER HEATER 'WH'. FLASH AND SEAL AT ROOF PENETRATION WEATHER TIGHT. SEE DETAIL 14/M5.1. TYPICAL PROPANE REGULATOR FROM 14 kPa (5 psi) BUILDING OPERATING PRESSURE TO PROPANE EQUIPMENT OPERATING PRESSURE. MOUNT PROPANE LINE ON ROOF ON PLASTIC OR RUBBER SUPPORTS ON 2m (6ft) CENTERS. NO EXPOSED STYROFOAM. HOT WATER RECIRC BALANCING BALL VALVES IN CEILING SPACE. SEE MAIN FLOOR WATER & PROPANE PLAN 1/M3.2 FOR CONTINUATION OF 25mm SOFT COLD WATER LINE, 19mm HOT WATER LINE, AND 13mm HOT WATER RECIRC LINE UP HIGH AT U/S OF ROOF. 19mm HOT WATER LINE, 25mm SOFT COLD WATER LINE, AND 13mm HOT WATER RECIRC LINE DOWN FROM SECOND FLOOR CEILING SPACE CONCEALED IN WALL AND INTO MAIN FLOOR CEILING SPACE. SEE MAIN FLOOR WATER & PROPANE PLAN 1/M3.2 FOR CONTINUATION. SEE MAIN FLOOR WATER & PROPANE PLAN 1/M3.2 FOR CONTINUATION OF 19mm - 14 kPa (5 psi) PROPANE LINE ALONG ROOF. SEE ENLARGED MECH ROOM PLAN 2/M3.3 FOR MORE DETAIL. 19mm COLD HARD WATER LINE DOWN CONCEALED IN WALL TO LOWER MAIN FLOOR CEILING SPACE. SEE MAIN FLOOR WATER & PROPANE PLAN 1/M3.2 FOR CONTINUATION. SEE MAIN FLOOR WATER & PROPANE PLAN 1/M3.2 FOR CONTINUATION OF 19mm COLD HARD WATER LINE ALONG U/S OF ROOF. 25mm COLD SOFT, 25mm HOT, AND 13mm PLASTIC FOOD GRADE RO WATER LINE DOWN CONCEALED IN WALL TO LOWER MAIN FLOOR CEILING SPACE. SEE MAIN FLOOR WATER & PROPANE PLAN 1/M3.2 FOR CONTINUATION. 32mm - 14 kPa (5 psi) PROPANE LINE CONTINUES ALONG ROOF. SEE MAIN FLOOR WATER AND PROPANE PLAN 1/M3.2 FOR CONTINUATION. 32mm - 14 kPa (5 psi) PROPANE LINE UP ALONG EXTERIOR WALL ONTO ROOF. SUPPORT PROPANE LINE ALONG WALL WITH UNISTRUT CHANNELS AND CLAMPS ON 2m (6ft) CENTERS. SEE MAIN FLOOR WATER AND PROPANE PLAN 1/M3.2 FOR CONTINUATION. 50mm CONDENSATE DRAIN DOWN FROM EVAPORATOR UNIT 'AC1' CONCEALED IN WALL TO MAIN FLOOR CEILING SPACE. PLUMBING KEYNOTES XX DENOTES KEYNOTE ON DWG 1 2 3 4 5 6 7 8 9 10 PLUMBING GENERAL NOTES PLUMBING EQUIPMENT SCHEDULE JS - JANITORS SINK SUPPLY AND INSTALL A FIAT MOLDED STONE MOP SERVICE SINK MSB2424 MADE OF STAIN PROOF MATERIALS W/ 255mm (10") HIGH WALLS MOLDED IN ONE PIECE. SINK TO BE C/W BUMPER GUARD, HOSE BRACKET, AND SEALANT. DRAIN TO BE FACTORY INSTALLED 302 STAINLESS STEEL WITH COMBINATION DOME STRAINER AND LINT BASKET. FAUCET TO BE TECK 28T2313 COMBINATION SUPPLY FITTING WITH HOSE END, VACUUM BREAKER, 70mm (2¾") MINI BLADE HANDLES, HEAVY C.P. BRASS P-TRAP, INTEGRAL STOPS, HEAVY DUTY "TUFF-TECK" STRUCTURES AND 2000mm (79") HOSE AND HANGER. CO - CLEANOUT (MEDIUM LOAD TRAFFIC - FINISHED AREAS) SUPPLY AND INSTALL A WADE MODEL 7000-R-1 FLOOR CLEANOUT C/W EPOXY COATED CAST IRON BODY W/ ANCHOR FLANGE, SECURED GASKETED SCORIATED COVER WITH 100mm (4") THREADED SHANK, AND HEAVY DUTY 150mm (6") ROUND ADJUSTABLE NICKEL BRONZE CLEANOUT TOP. FOR WATER PROOFED AREAS PROVIDE FC FLANGE WITH FLASHING CLAMP. CO - CLEANOUT (UNFINISHED AREAS) SUPPLY AND INSTALL A WADE MODEL 7000-R-4 FLOOR CLEANOUT C/W EPOXY COATED CAST IRON BODY W/ ANCHOR FLANGE, SECURED GASKETED SCORIATED COVER WITH 100mm (4") THREADED SHANK, AND HEAVY DUTY 150mm (6") ROUND ADJUSTABLE NICKEL BRONZE CLEANOUT TOP. FOR WATER PROOFED AREAS PROVIDE FC FLANGE WITH FLASHING CLAMP. RD1 - ROOF DRAIN #1 SUPPLY AND INSTALL A WADE MODEL 3000-DF-42-52-53 100mm (4") EPOXY COATED CAST IRON LARGE AREA ROOF DRAIN W/ FLASHING CLAMP WITH INTEGRAL GRAVEL STOP, DECK CLAMP, AND METAL DOME STRAINER ALL TO SUIT STYLE OF ROOF AND INSULATION THICKNESS. RD2 - ROOF DRAIN #2 SUPPLY AND INSTALL A WADE MODEL 3000-DF-42-52-53 150mm (6") EPOXY COATED CAST IRON LARGE AREA ROOF DRAIN W/ FLASHING CLAMP WITH INTEGRAL GRAVEL STOP, DECK CLAMP, AND METAL DOME STRAINER ALL TO SUIT STYLE OF ROOF AND INSULATION THICKNESS. RDO - ROOF DRAIN OUTLET SUPPLY AND INSTALL A JR SMITH MODEL 1771 250mm (10") NICKEL BRONZE DOWNSPOUT NOZZLE WITH FLANGE AND PRE-DRILLED COUNTER SUNK MOUNTING HOLES. FD1 - FLOOR DRAIN #1 (LIGHT DUTY) SUPPLY AND INSTALL A WADE MODEL 1000-C-R5 75mm (3") FLOOR DRAIN. ALL EPOXY COATED CAST IRON BODY, CUSTOM ETCHED LOGO, TRAP GUARD, ANCHOR FLANGE W/ SEEPAGE OPENINGS AND ADJUSTABLE ROUND HEAVY DUTY STAINLESS STEEL STRAINER. FD2 - FLOOR DRAIN #2 (HEAVY DUTY) SUPPLY AND INSTALL A WADE MODEL 1100-MR5-HD 75mm (3") FLOOR DRAIN. ON-GRADE EPOXY COATED CAST IRON BODY, CUSTOM ETCHED LOGO, TRAP GUARD, ANCHOR FLANGE W/ SEEPAGE OPENINGS AND ADJUSTABLE ROUND HEAVY DUTY STAINLESS STEEL STRAINER. PD - PIPE DRAIN SUPPLY AND INSTALL A FIELD FABRICATED 75mm (3") PIPE DRAIN W/ TRAP. PROVIDE A 100mm (4") COLLAR ON TOP OF DRAINS WHICH ARE LOCATED BENEATH REFRIGERATED DISPLAY CASES AND HAVE MORE THAN ONE CONDENSATE DRAIN PIPED TO IT. SEE DETAIL 4/M5.1. SHPD - SMOKEHOUSE PIPE DRAIN SUPPLY AND INSTALL A ZURN MODEL Z1910 200mm x 200mm (8"x8") SANI-FLOR RECEPTOR OR EQUAL. UNIT TO BE 200mm x 200mm (8"x8") AND 150mm (6") DEEP C/W MEDIUM DUTY GRATE WITH 7/16 SLOTTED OPENINGS, ACID RESISTANT PORCELAIN ENAMEL INTERIOR AND TOP, AND ABS ANTI-SPLASH INTERIOR BOTTOM DOME STRAINER. PROVIDE DEEP SEAL TRAP AT CONNECTION TO SANITARY SEWER LINE. TD1 - TRENCH DRAIN #1 SUPPLY AND INSTALL AN ACO TRENCH DRAIN MODEL K100 PRECAST DRAINAGE CHANNEL. UNIT TO BE 1 METER LONG C/W 490Q HEAVY DUTY SLOTTED STAINLESS STEEL GRATE. PROVIDE DEEP SEAL TRAP AT CONNECTION TO SANITARY SEWER LINE. 11 12 13 15 16 SCALE: NTS 3 WATER HEATER PIPING DETAIL 17 1 : 100 1 MEZZANINE PLAN 18 19 20 21 14 TD2 - TRENCH DRAIN #2 SUPPLY AND INSTALL AN ACO TRENCH DRAIN MODEL K100 PRECAST DRAINAGE CHANNEL. UNIT TO BE 2 METERS LONG C/W 490Q HEAVY DUTY SLOTTED STAINLESS STEEL GRATE. PROVIDE DEEP SEAL TRAP AT CONNECTION TO SANITARY SEWER LINE. TD3 - TRENCH DRAIN #3 SUPPLY AND INSTALL AN ACO TRENCH DRAIN MODEL K100 PRECAST DRAINAGE CHANNEL. UNIT TO BE 5 METERS LONG C/W 490Q HEAVY DUTY SLOTTED STAINLESS STEEL GRATE. PROVIDE DEEP SEAL TRAP AT CONNECTION TO SANITARY SEWER LINE. TD4 - TRENCH DRAIN #4 SUPPLY AND INSTALL AN ACO TRENCH DRAIN MODEL K100 PRECAST DRAINAGE CHANNEL. UNIT TO BE 6 METERS LONG C/W 490Q HEAVY DUTY SLOTTED STAINLESS STEEL GRATE. PROVIDE DEEP SEAL TRAP AT CONNECTION TO SANITARY SEWER LINE. GI1 & GI2 - GREASE INTERCEPTOR #1 & #2 SUPPLY AND INSTALL A SCHIER PRODUCTS MODEL GB-50 GREASE INTERCEPTOR. UNIT TO BE RECESSED IN FLOOR. UNIT CAPACITY IS TO BE 3.15 L/s (50 gpm) AND 113 kg (249 lbs) GREASE HOLDING CAPACITY C/W HIGH DENSITY POLYETHYLENE CONSTRUCTION, FIELD ADJUSTABLE RISER SYSTEM, BUILT-IN FLOW CONTROL, BUILT-IN TEST CAPS, AND THREE OUTLET OPTIONS. POSITION GREASE INTERCEPTOR SO AS NOT TO CONFLICT WITH LEG SUPPORTS FOR SINKS/TABLES. SEE DETAIL 5/M5.1. GI3, GI4 & GI5 - GREASE INTERCEPTOR #3, #4 & #5 SUPPLY AND INSTALL A SCHIER PRODUCTS MODEL GB-35 GREASE INTERCEPTOR. UNIT TO BE RECESSED IN FLOOR. UNIT CAPACITY IS TO BE 2.21 L/s (35 gpm) AND 64.4 kg (142 lbs) GREASE HOLDING CAPACITY C/W HIGH DENSITY POLYETHYLENE CONSTRUCTION, FIELD ADJUSTABLE RISER SYSTEM, BUILT-IN FLOW CONTROL, BUILT-IN TEST CAPS, AND THREE OUTLET OPTIONS. POSITION GREASE INTERCEPTOR SO AS NOT TO CONFLICT WITH LEG SUPPORTS FOR SINKS/TABLES. SEE DETAIL 5/M5.1. PC - PRODUCE DISPLAY CASE SUPPLIED AND INSTALLED BY REFRIGERATION CONTRACTOR. MECHANICAL CONTRACTOR TO PIPE CONDENSATE DRAIN TO NEAREST PIPE DRAIN AND PROVIDE 13mm (½") RO WATER LINE CONNECTION TO HUMIDIFIERS/MISTERS. CO-ORDINATE WITH REFRIGERATION CONTRACTOR. DSC - DELI SERVICE CASE SUPPLIED AND INSTALLED BY REFRIGERATION CONTRACTOR. MECHANICAL CONTRACTOR TO PIPE CONDENSATE DRAIN TO NEAREST PIPE DRAIN AND PROVIDE 13mm (½") FILTERED WATER LINE CONNECTION TO HUMIDIFIER/MISTERS. CO-ORDINATE WITH REFRIGERATION CONTRACTOR. MC - MEAT DISPLAY CASE SUPPLIED AND INSTALLED BY REFRIGERATION CONTRACTOR. MECHANICAL CONTRACTOR TO PIPE CONDENSATE DRAIN TO NEAREST PIPE DRAIN AND PROVIDE 13mm (½") FILTERED WATER LINE CONNECTION TO HUMIDIFIER/MISTERS. CO-ORDINATE WITH REFRIGERATION CONTRACTOR. MCC - MISTER CONTROL CENTER MISTER CONTROL CENTER PANEL SUPPLIED BY REFRIGERATION CONTRACTOR. INSTALLED AND PLUMBED BY MECHANICAL CONTRACTOR. R - REFRIGERATED DISPLAY CASE, COOLER, OR FREEZER CONTRACTOR TO PROVIDE CONDENSATE DRAIN CONNECTION TO NEAREST PIPE DRAIN. CO- ORDINATE WITH REFRIGERATION CONTRACTOR. HB1 - INTERIOR HOSEBIB/WASHDOWN STATION SUPPLY AND INSTALL A WOODFORD MODEL 26CP OR EQUAL STANDARD 13mm (½") HOSE BIB C/W VACUUM BREAKER, BACKFLOW PROTECTION, METAL WHEEL HANDLE, ROUGH BRASS FINISH, AND AUTOMATIC DRAIN. SEE DETAIL 2/M5.1. HB - EXTERIOR NON-FREEZE HOSE BIB SUPPLY AND INSTALL A WATTS MODEL HY-725 NON-FREEZE, KEY OPERATED WALL HYDRANT, NICKEL BRONZE BOX AND DOOR, CHROME PLATED HYDRANT FACE, INTEGRAL VACUUM BREAKER, ¾" (19mm) HOSE CONNECTION, ¾" (19mm) FEMALE x 1" (25mm) MALE PIPE CONNECTION, ALL BRONZE HEAD, SEAT CASTING AND INTERNAL WORKING PARTS, BRONZE WALL CASING, AND LOOSE KEY. HW - BARRIER FREE WATER CLOSET (BARRIER FREE FLUSH TANK, 4.8Lpf) SUPPLY AND INSTALL AN AMERICAN STANDARD "CHAMPION PRO" MODEL 211AA.154 LOW FLUSH, HIGH EFFICIENCY, ELONGATED RIM, BARRIER FREE WATER CLOSET OR EQUAL. UNIT TO BE C/W 419mm (16½") HIGH BOWL, INSULATED TANK, 4.8 LITRES/FLUSH (1.07gpf), LEED QUALIFIED, FULLY GLAZED TRAPWAY, OVERSIZED 75mm FLUSH VALVE WITH CHEMICAL RESISTANT FLAPPER, AND BOLT DOWN TANK COVER. SUPPLY TO BE TECK 47T316 RIGID/FLEX CLOSET SUPPLY WITH LOCKSHIELD ANGLE STOPS AND FLEXIBLE RISER. PROVIDE AMERICAN STANDARD MODEL 5901.100 HEAVY DUTY OPEN FRONT SEAT LESS COVER. WC - TOILET - FLOOR MOUNTED TANK (4.8 Lpf) SUPPLY AND INSTALL AN AMERICAN STANDARD "CADET PRO" MODEL 3517C.101 LOW FLUSH, HIGH EFFICIENCY, ELONGATED RIM WATER CLOSET OR EQUAL. UNIT TO BE C/W INSULATED TANK, 4.8 LITRES/FLUSH (1.07gpf), FULLY GLAZED TRAPWAY, AND BOLT-DOWN TANK COVER. SUPPLY TO BE TECK 47T316 RIGID/FLEX CLOSET SUPPLY WITH LOCKSHIELD ANGLE STOPS AND FLEXIBLE RISER. PROVIDE AMERICAN STANDARD MODEL 5901.100 HEAVY DUTY OPEN FRONT SEAT LESS COVER. HV - BARRIER FREE COUNTER MOUNTED LAVATORY (HANDS-FREE FAUCET) SUPPLIED AND INSTALLED BY OTHERS C/W TRIM. MECHANICAL CONTRACTOR TO PROVIDE ½" HOT AND COLD WATER SUPPLIES. TRAP TO BE TECK 33T301, 32mm(1¼") CAST BRASS P-TRAP. WASTE TO BE TECK 33T290, 32mm(1¼") OFFSET BRASS OPEN GRID. V - COUNTER MOUNTED LAVATORY (MANUAL FAUCET) SUPPLIED AND INSTALLED BY OTHERS C/W TRIM. MECHANICAL CONTRACTOR TO PROVIDE ½" HOT AND COLD WATER SUPPLIES. TRAP TO BE TECK 33T301, 32mm(1¼") CAST BRASS P-TRAP. WASTE TO BE TECK 33T260, 32mm(1¼") BRASS OPEN GRID. HS1, HS2, HS3, HS4, HS5, HS6, HS7, HS8, HS9, HS10, & HS11 - HAND SINK #1, #2, #3, #4, #5, #6, #7, #8, #9, #10, & #11 SUPPLY AND INSTALL AN ARISTALINE MODEL WHB 1819 STAINLESS STEEL WALL MOUNT SINK WITH 18-8 TYPE 16 GA. STAINLESS STEEL, SIDE WALL BRACKETS, AND WALL HANGER. SINK TO BE C/W SLOAN MODEL EBF-650 SENSOR ACTIVATED, BATTERY POWERED, 100mm (4") CENTERSET HAND WASHING FAUCET OR EQUAL. FAUCET TO PROVIDE 0.03 L/s (0.5gpm) C/W CHROME PLATED CAST BRASS FINISH, TEMPORARY-OFF FEATURE FOR CLEANING, SPLASH- PROOF CIRCUIT CONTROL MODULE, SENSOR RANGE ADJUSTMENT SCREW, LOW BATTERY LED INDICATOR LIGHT, VARIABLE TIME OUT SETTINGS, SERVICEABLE FILTERED SOLENOID VALVE, BAK-CHEK TEE FOR HOT/COLD SUPPLY, VANDAL RESISTANT SPRAY HEAD WITH PRESSURE COMPENSATING FLOW CONTROL, METAL JACKETED WIRE PROTECTION FOR SENSOR LEAD, APPROPRIATE MOUNTING HARDWARE, 4 ALKALINE BATTERIES (2 YEAR LIFE), AND 0.03 L/s (0.5gpm) AERATED STREAM SPRAY INSERT. SUPPLY TO BE TECK 47T2512 RIGID/ANGLE SUPPLIES WITH LOCKSHIELD STOPS AND FLEXIBLE RISERS. TRAP TO BE TECK 33T301 32mm (1¼") CAST BRASS P-TRAP. WASTE TO BE TECK 33T260 32mm (1¼") CAST BRASS OPEN GRID. HS8 & HS9 - HAND SINK #8 & #9 HAND SINK SUPPLIED BY OTHERS COMPLETE WITH TRIM. CONTRACTOR TO INSTALL COMPLETE WITH 13mm (1/2") HOT AND COLD WATER SUPPLIES, 38mm (11/2") DRAIN WITH P-TRAP, AND VENTING. S - COUNTER MOUNTED SINGLE COMPARTMENT SINK SINK TO BE SUPPLIED BY MILLWORK SUPPLIER COMPLETE WITH TRIM. CONTRACTOR TO INSTALL COMPLETE 13mm (½") HOT AND COLD WATER SUPPLIES WITH STOP AND 38mm (1½") P- TRAP WITH CLEANOUT. DIS - DISINFECTION SYSTEM CONTRACTOR TO PROVIDE 13mm (½") HOT WATER AND 13mm (½") COLD WATER CONNECTION TO OWNER SUPPLIED ZEP DISINFECTION SYSTEM. MS - MEAT PREP SINK SINK TO BE SUPPLIED BY REFRIGERATION CONTRACTOR AND INSTALLED AND CONNECTED BY MECHANICAL CONTRACTOR C/W WATER SUPPLIES, VENT, P-TRAP, AND WASTE THROUGH GREASE INTERCEPTOR. SHS - SAUSAGE KITCHEN PREP SINK SINK TO BE SUPPLIED BY REFRIGERATION CONTRACTOR AND INSTALLED AND CONNECTED BY MECHANICAL CONTRACTOR C/W WATER SUPPLIES, VENT, P-TRAP, AND WASTE THROUGH GREASE INTERCEPTOR. DS - DELI PREP SINK SINK TO BE SUPPLIED BY REFRIGERATION CONTRACTOR AND INSTALLED AND CONNECTED BY MECHANICAL CONTRACTOR C/W WATER SUPPLIES, VENT, P-TRAP, AND WASTE THROUGH GREASE INTERCEPTOR. CS - CHICKEN PREP SINK SINK TO BE SUPPLIED BY REFRIGERATION CONTRACTOR AND INSTALLED AND CONNECTED BY MECHANICAL CONTRACTOR C/W WATER SUPPLIES, VENT, P-TRAP, AND WASTE THROUGH GREASE INTERCEPTOR. BS - BAKERY SINK SINK TO BE SUPPLIED BY REFRIGERATION CONTRACTOR AND INSTALLED AND CONNECTED BY MECHANICAL CONTRACTOR C/W WATER SUPPLIES, VENT, P-TRAP, AND WASTE THROUGH GREASE INTERCEPTOR. SS - SUSHI PREP SINK SINK TO BE SUPPLIED BY REFRIGERATION CONTRACTOR AND INSTALLED AND CONNECTED BY MECHANICAL CONTRACTOR C/W WATER SUPPLIES, VENT, P-TRAP, AND WASTE THROUGH GREASE INTERCEPTOR. PS - PRODUCE SINK SINK TO BE SUPPLIED BY REFRIGERATION CONTRACTOR AND INSTALLED AND CONNECTED BY MECHANICAL CONTRACTOR C/W WATER SUPPLIES, VENT, P-TRAP, AND WASTE. IM - ICE MACHINE SUPPLIED BY OWNERS. CONTRACTOR TO INSTALL C/W ½" PLASTIC FOOD GRADE RO WATER LINE AND INDIRECT DRAIN CONNECTION TO NEAREST PIPE DRAIN. WH - PROPANE-FIRED WATER HEATER SUPPLY AND INSTALL A BRADFORD WHITE MODEL EF-100T-199-3X(A) COMMERCIAL POWER DIRECT VENT PROPANE-FIRED WATER HEATER OR EQUAL. UNIT TO PROVIDE 58.56 kW (199.999 MBH) HEATING INPUT, 378.5 L (100 US GAL) STORAGE CAPACITY, 904.7 L/h (239 gph) RECOVERY AT 38°C (100°F) TEMPERATURE RISE. UNIT TO BE C/W DIRECT SPARK IGNITION, T&P SAFETY RELIEF VALVE, DRAIN VALVE, MAGNESIUM ANODE RODS, ICON HD TEMPERATURE CONTROL, DIAGNOSTIC, AND SYSTEM IGNITION CONTROL BOARD W/ LCD DISPLAY, PREMIX POWER BURNER, SINGLE EXHAUST PRESSURE SWITCH, 75mm (3") VENT, AND 75mm (3") COMBUSTION AIR INTAKE UP THRU ROOF C/W CONCENTRIC VENT AND VERTICAL TERMINATION KITS. UNIT ELECTRICAL TO BE 115 VOLT, SINGLE PHASE. SEE DRAWING M2.2 FOR VENTILATION AND DETAIL 4/M3.3 FOR PIPING SCHEMATIC. ET - POTABLE EXPANSION TANK SUPPLY AND INSTALL A WATTS MODEL PLT-20 POTABLE WATER EXPANSION TANK OR EQUAL. SEE DETAIL 4/M3.3. RP - HOT WATER RECIRCULATION PUMP SUPPLY AND INSTALL A BELL & GOSSET MODEL NBF-12 L/W BRONZE INLINE CIRCULATOR OR EQUAL. UNIT TO PROVIDE 0.32 L/s @ 24 kPa (5 gpm @ 8 FT HEAD) C/W FRAC. H.P. MOTOR @1180 rpm AND 115 VOLT, SINGLE PHASE. SEE DETAIL 4/M3.3 FOR PIPING SCHEMATIC. WS - WATER SOFTENER SUPPLY AND INSTALL A WATERGROUP MODEL TMI-120-11/2" OR EQUAL DUPLEX WATER SOFTENER. UNIT TO BE TWIN ALTERNATING TYPE WITH A 108,000 GRAIN CAPACITY PER TANK (216,000 GRAINS TOTAL) AT 10 LBS SALT PER CUBIC FOOT (40 LBS SALT PER REGENERATION), AND A 1.5"-9500 CONTROL VALVE 2 L/s @ 103kPa AND 2.78 L/s @ 172.37 kPa (32 GPM @ 15 PSI AND 44 GPM @ 25 PSI DROP), 0.11 m³ (4 ft³) OF RESIN PER TANK, AND BRINE TANK. UNIT ELECTRICAL TO BE 115 VOLT, SINGLE PHASE. SEE WATER TREATMENT ROOM PIPING SCHEMATIC 16/M5.1. RO - REVERSE OSMOSIS MACHINE SUPPLIED BY OTHERS. CONTRACTOR TO INSTALL WITH WATER SUPPLY AND DRAIN CONNECTIONS AS PER WATER TREATMENT PIPING SCHEMATIC 16/M5.1. SP - SUMP PUMP SUPPLY AND INSTALL A HYDROMATIC MODEL SPD 50 AH1 SUBMERSIBLE SUMP PUMP OR EQUAL. UNIT TO PUMP 170.3 L/min @ 95.65 kPa (45 GPM @ 32 FEET OF HEAD) COMPLETE WITH A ½ H.P. MOTOR @ 3450 RPM. UNIT TO BE COMPLETE WITH AUTOMATIC OPERATION, DIAPHRAM PRESSURE SWITCH, 50mm (2") DISCHARGE VALVE, DISCHARGE CHECK VALVE, AND WATER RESISTANT POWER CORD WITH MOLDED PLUG. WPB - WATER PRESSURE BOOSTER SYSTEM SUPPLY AND INSTALL A POTABLE PRESSURE BOOSTER SYSTEM TO BE A GRUNDFOS EZ BOOST SYSTEM WITH BMQU BOOSTER PUMP, TANK AND CONTROLLER. UNIT TO BE MODEL 30BMQE 10C- 130 TO PROVIDE 151.4 L/min @ 275.8 kPa (40 GPM @ 40 PSI) BOOST PRESSURE WITH A 1 HP MOTOR AT 208 VOLT, SINGLE PHASE. UNIT TO BE COMPLETE WITH STAINLESS STEEL SLEEVE/TANK, MSE3 MOTOR, EZ BOOST VARIABLE SPEED CONTROLLER, PRESSURE SENSOR KIT, 2 GALLON STAINLESS STEEL/POLYPROPYLENE LINED DIAPHRAGM TANK, AND WALL MOUNTING BRACKETS. UNIT ELECTRICAL TO BE 208 VOLT, SINGLE PHASE, WITH A RATED CURRENT OF 9.5 AMPS AND A LOCKED MOTOR CURRENT OF 11.1 AMPS. SEE DETAIL 9/M5.1. CF - CALCITE FILTER SUPPLIED AND INSTALLED BY OWNER'S WATER TREATMENT SYSTEM SUPPLIER. PW - PAN WASHER SUPPLIED BY OWNERS. CONTRACTOR TO INSTALL C/W 38mm (1½") INDIRECT DRAIN CONNECTION TO PIPE DRAIN AND 19mm (¾") HOT WATER AND 13mm (½") COLD WATER CONNECTION C/W PRESSURE REDUCING VALVES AS PER MANUFACTURER'S SPECIFICATIONS. COM - COMBI OVEN SUPPLIED BY OTHERS. MECHANICAL CONTRACTOR TO INSTALL C/W PROPANE ROUGH-IN WITH SHUT-OFF VALVE AND STAINLESS STEEL FLEX CONNECTION TO COMBI OVEN. PROVIDE COPPER INDIRECT DRAIN TO NEAREST PIPE DRAIN (DO NOT USE ABS) AND 19mm (¾") SOFT COLD WATER CONNECTION AS PER MANUFACTURER'S REQUIREMENTS. PIPE DRAIN LINE TO BE STEAM GRADE PVC OR CAST IRON FOR A DISTANCE OF 3m (10ft) FROM THE PIPE DRAIN DUE TO HIGH TEMPERATURE. DO NOT USE ABS. SEE DRAWING M2.1 FOR VENTILATION. RET - RETARDER PROOFER BAKERY RETARDER PROOFER TO BE SUPPLIED BY OTHERS. PROVIDE FLOOR DRAIN, 13mm (½") SOFT COLD WATER CONNECTION AND INDIRECT DRAIN CONNECTION TO NEAREST PIPE DRAIN. PIPE DRAIN LINE TO BE STEAM GRADE PVC OR CAST IRON FOR A DISTANCE OF 3m (10ft) FROM THE PIPE DRAIN DUE TO HIGH TEMPERATURE. DO NOT USE ABS. O - RACK OVEN HOBART RACK OVEN BY OTHERS. CONTRACTOR TO PROVIDE PROPANE ROUGH-IN WITH SHUT OFF VALVE AND STAINLESS STEEL FLEX CONNECTION. ALSO PROVIDE 13mm (½") COLD SOFT WATER CONNECTION AND INDIRECT DRAIN CONNECTION TO NEAREST PIPE DRAIN. PIPE DRAIN LINE TO BE STEAM GRADE PVC OR CAST IRON FOR A DISTANCE OF 3m (10ft) FROM THE PIPE DRAIN DUE TO HIGH TEMPERATURE. DO NOT USE ABS. REFER TO DRAWING M2.1 FOR VENTILATION. SM - MEAT SMOKER MACHINE MEAT SMOKER SUPPLIED BY OTHERS. CONTRACTOR TO CONNECT MEAT SMOKER TO PIPE DRAIN THRU GREASE TRAP AND PROVIDE 150mmØ (6"Ø) STAINLESS STEEL TYPE L VENT UP THROUGH ROOF WITH 25mm (1") DRAIN FROM VENT TO PIPE DRAIN. ALSO PROVIDE 13mm (½") FILTERED COLD WATER LINE, 6mm (¼") HOT WATER CONNECTION TO INDUCT RINSE, 6mm (¼") HOT WATER CONNECTION TO INDUCT WASH, 13mm (½") COLD WATER CONNECTION FOR FIRE SAFETY, AND 25mm (1") INDIRECT DRAIN CONNECTION TO PIPE DRAIN 'SHPD'. SEE DETAIL X/M5.1. WM - WATER MARKET SUPPLIED BY OTHERS. CONTRACTOR TO INSTALL WITH 19mm (¾") PLASTIC FOOD GRADE RO WATER CONNECTION AND INDIRECT DRAIN CONNECTION TO PIPE DRAIN. RTU1, RTU2, RTU3, RTU4, RTU5, RTU6, RTU7 & RTU8 - ROOF TOP UNITS #1, #2, #3, #4, #5, #6, #7 & #8 SEE DRAWING M2.2 FOR SPECIFICATIONS. UH1, UH2, UH3 & UH4 - PROPANE UNIT HEATERS #1, #2, #3 & #4 SEE DRAWING M2.2 FOR SPECIFICATIONS. 1 : 50 2 ENLARGED MECH ROOM PLAN 1 BID SET 2016-10-17

3 HEATER PIPING DETAIL M3 - RNF Ventures Ltd. · 23. note all penetrations thru roof to be sealed with pitch boxes. see detail 14/m5.1. 24. provide isolation valves on the water supply

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 3 HEATER PIPING DETAIL M3 - RNF Ventures Ltd. · 23. note all penetrations thru roof to be sealed with pitch boxes. see detail 14/m5.1. 24. provide isolation valves on the water supply

A

A

C

C

E

E

G

G

H

H

2 2

3 3

6 6

8 8

44

55

77

B

B

D

D

F

F

RTU7

UH4

WH

WS

RTU8

AC1

SALES102

CORRIDOR201

STAIRS-1

SERVERROOM

204

OFFICE203

FEMALE206

MALE205

CORR.202

STAFF ROOM207 OFFICE

208

COMPRESSORROOM

210

MECHANICAL211

OFFICE212

OFFICE213

OFFICE214

OFFICE215

CORRIDOR209

STAIRS-2

13

1410

R

9

1919

1213

19 25

19

CO

FD

CO

WC

WC

V

V

DS

21

50

75

1

5FD

7575

75

50

32

38

32

38

75

13

13

131319

1919

1375

19

17

15

15

1515193832

19 1919

2

R 19

19

19

32 10 32 10

913383219

1318

13

25

2

2 11

16

1119

13 25

19 1319

H

H

8 8

WH

WS

COMPRESSORROOM

210

MECHANICAL211

UH4

OFFICE212

7R

9

13

19

PD

CO PD

20

PD

R

98

10

19

RP

HRT

ET3

3

3

34

SENTINELPOLISHER

4RO PRODUCTIONCABINET

4RO STORAGETANK

4

4

POST CARBONFILTER

4UV

4UV

420" FOOD GRADEPOLYPHOSPHATEFILTER

4

CARBONBACKWASHFILTER

4 MAINLINEFILTER 5

FD

1038

13

32

1932

32 75 75 75

1

7575

1919 19

75

38

38

10

10

38

38

32

25

75 25

25

32

32

10

38 6

10

2525

25

19

19

19

19

32

19

1938 32

19

A0 ( 8

41 x

1189

)

15 10 5 0 10 20 30 40 50 60

DRAWN :

CHECKED :

DRAWING NAME :

PROJECT NUMBER :

PROJECT NAME :

REVISIONS :

NO. DESCRIPTION : DATE :YYYY-MM-DD

All drawings and specifications are the property of aodbt and/or theirsubconsultants and may be reproduced only with their written permission.Information shown herein is for the use on this project only. Contractor shallverify and be responsible for site dimensions and conditions, and informconsultant of any variations that may occur. Dimensional text shall governover any scaled dimensions.

STAMPS :

www.aodbt.com

202 - 21 11th St EPrince Albert, SKS6H 0Z8306.922.5101

235 Ave D NorthSaskatoon, SKS7L 1M7306.244.5101

architecture + interior design

CIVIL ENGINEERCIVIL ENGINEER

STRUCTURAL ENGINEER

MECHANICAL ENGINEER

ELECTRICAL ENGINEER

CLIENT

FEDERATEDCO-OPERATIVESLIMITED

DATE :

PROJECT #: 4933

M:\Current Projects\4933 Flin Flon Co-op\4933 DRAWINGS\4933 WORKING DRAWINGS\4933-MECH Flin Flon Co-op-V16.rvt14/10/2016 4:12:25 PM

GAS

SMH

16.067

North of 53Consumers CO-OPFlin Flon Food Store

100 PTH 10A, Flin Flon, Manitoba

M3.3

MEZZANINE PLUMBINGPLAN

2016/10/14

1. ALL PLUMBING LINES SHOWN SCHEMATICALLY.2. ALL WATER PIPING TO RUN CONCEALED IN FINISHED AREAS WITHIN CEILING SPACE AND WALLS. PAINT ALL EXPOSED

PIPING AS PER ARCHITECTURAL. ALL SEWER LINES TO RUN CONCEALED BELOW CONCRETE SLAB, WITHIN CEILINGSPACE, AND/OR IN WALLS.

3. ALL WATER LINES TO BE COVERED WITH 25mm (1") INSULATION AND WITH PVC JACKET IN EXPOSED AREAS.4. ALL EQUIPMENT TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND

RECOMMENDATIONS.5. ALL PIPING TO FIXTURES AND EQUIPMENT TO RUN CONCEALED WHERE POSSIBLE.6. ALL WATER CONNECTIONS TO FIXTURES TO BE 13mm (½") UNLESS OTHERWISE SPECIFIED.7. CONTRACTOR TO SUPPLY AND INSTALL PLUMBING VENTS, TRAP SEAL PRIMERS, CLEANOUTS, AND ISOLATION VALVES

AS PER CODE.8. INSTALL ALL GAS FIRED EQUIPMENT AND PIPING IN ACCORDANCE WITH THE CANADIAN GAS CODE AND GAS UTILITY

REQUIREMENTS.9. SOLDERS AND FLUXES HAVING A LEAD CONTENT IN EXCESS OF 0.2% SHALL NOT BE USED.10. PVC AND PLASTIC PIPING MAY BE USED WHERE PERMITTED BY CODE. ALL PVC PIPING WITHIN RETURN AIR CEILING

PLENUMS TO BE XFR RATED.11. ALL PLUMBING TO BE INSTALLED IN ACCORDANCE WITH THE CANADIAN PLUMBING CODE, PROVINCIAL PLUMBING

CODES, AND CITY BYLAWS.12. PROVIDE FIRESTOPS AT ALL PIPING THAT PASSES THROUGH FIRE SEPARATIONS.13. PLUMBING CONTRACTOR TO CONNECT CONDENSATE DRAINS FROM ALL REFRIGERATED DISPLAY CASES, COOLER,

AND FREEZERS TO PIPE DRAINS. CO-ORDINATE WITH REFRIGERATION CONTRACTOR. SEE REFRIGERATION DRAWINGSFOR CONDENSATE DRAIN PLAN.

14. PAINT EXPOSED CONDENSATE LINES IN AND OUT OF FREEZERS, COOLERS AND MEAT PREP AREA TO MATCH WALLS.15. PROVIDE A COPY OF PLUMBING AND GAS PERMITS TO OWNER.16. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS THAT ARE NOT ACCESSIBLE OR DIFFICULT TO SERVICE. PROVIDE A

MANIFOLD, MANUAL VALVES, AND APPROPRIATE UNDERSLAB ⅜" TUBING TO SERVE TRAP PRIMERS. TRAP PRIMERS ARENOT REQUIRED FOR PIPE DRAINS WHICH ARE USED TO DRAIN CONDENSATE FROM REFRIGERATION CASES ANDEVAPORATOR COILS.

17. ALL NEW FLOOR DRAINS FOR REFRIGERATED WALK IN BOXES AND REFRIGERATION CASES SHALL HAVE DEEP SEALTRAPS.

18. PIPE DRAIN DIMENSIONS SHOWN ARE FOR REFERENCE ONLY. PIPE DRAINS MUST NOT BE VISIBLE FROM FRONT OFREFRIGERATED CASES ON SALES FLOOR AND MUST BE COMPLETELY CONCEALED BENEATH DISLAY CASE, BEHINDKICKPLATES. COORDINATE WITH REFRIGERATION CONTRACTOR.

19. ALL PIPE DRAIN DIMENSIONS SHOWN ARE FOR REFERENCE ONLY. ALL PIPE DRAINS AT FREEZERS AND COOLERS FORCONDENSATE MUST BE INSTALLED AS CLOSE AS POSSIBLE TO FREEZER AND COOLER WALLS. CO-ORDINATE WITHGENERAL CONTRACTOR AND REFRIGERATION CONTRACTOR. CONTRACTOR WILL BE RESPONSIBLE TO RELOCATE PIPEDRAINS AT THEIR OWN COST IF IT IS DETERMINED THAT THE PIPE DRAINS ARE TOO FAR AWAY FROM FREEZER/COOLER WALLS CAUSING TRIPPING HAZARDS IN TRAFFIC AREAS.

20. PROVIDE TRUEBRO PREFABRICATED INSULATION PACKAGE OVER ALL EXPOSED WATER SUPPLIES AND WASTES ATBARRIER FREE SINKS DESIGNATED AS "HV".

21. DRAIN LINES WITHIN WALK-IN FREEZER AND COOLERS TO BE INSTALLED TIGHT ALONG INTERIOR COOLER WALLS @ A1% SLOPE.

22. WATER LINES TO PLUMBING FIXTURES IN MEAT PREP AREA TO BE INSTALLED EXPOSED ON WAREHOUSE SIDE OFCOOLER PANELS AND NOT CONCEALED WITHIN COOLER PANEL WALLS.

23. NOTE ALL PENETRATIONS THRU ROOF TO BE SEALED WITH PITCH BOXES. SEE DETAIL 14/M5.1.24. PROVIDE ISOLATION VALVES ON THE WATER SUPPLY LINES TO ALL PLUMBING FIXTURES INCLUDING PRODUCTION

SINKS, JANITOR MOP SINK, ICE MACHINE, PROOFER, ETC.25. COORDINATE LOCATION OF ALL PLUMBING LINES WITH REFRIGERATION SO AS TO PREVENT LOCATION CONFLICTS.

REFRIGERATION LINES TO TAKE PRIORITY.26. EXPOSED WATER SUPPLIES AT WATER CLOSETS TO BE CHROME. NO EXPOSED PLASTIC PIPING PERMITTED.

75mmØ SANITARY SEWER LINE UP FROM BELOW SLAB CONCEALED IN WALL AND INTO MAIN FLOOR CEILING SPACE.SEE MAIN FLOOR SEWER PLAN 1/M3.1 FOR CONTINUATION.

SEE MAIN FLOOR WATER & PROPANE PLAN 1/M3.2 FOR CONTINUATION OF WATER SUPPLY LINES UP HIGH AT U/S OFWAREHOUSE ROOF STRUCTURE/WITHIN BAKERY/DELI CEILING SPACE.

SEE WATER HEATER PIPING DETAIL 3/M3.3 FOR PIPING SCHEMATIC OF HEAT RECLAIM TANK 'HRT', WATER HEATER'WH', POTABLE WATER EXPANSION TANK 'ET', AND HOT WATER RECIRC PUMP 'RP'.

SEE WATER TREATMENT SYSTEM PIPING SCHEMATIC 16/M5.1 FOR CONNECTION OF WATER TREATMENT EQUIPMENT.

75mmØ PLUMBING VENT UP FROM MAIN FLOOR CONCEALED IN WALL AND THRU ROOF. FLASH AND SEAL AT ROOFPENETRATION WEATHER TIGHT. PROVIDE THALER #SJ-26 INSULATED ALUMINUM STACK JACK WITH REMOVABLECOVER. SEE MAIN FLOOR SEWER PLAN 1/M3.1 FOR CONTINUATION.

SEE MAIN FLOOR WATER & PROPANE PLAN 1/M3.2 FOR CONTINUATION OF 38mm HARD COLD WATER LINE UP FROMLOWER MAIN FLOOR CONCEALED WITHIN WALL TO U/S OF ROOF.

19mm PROPANE LINE DOWN THROUGH ROOF TO UNIT HEATER 'UH4'. FLASH AND SEAL AT ROOF PENETRATIONWEATHER TIGHT. TRANSITION LINE TO 13mm ONCE INSIDE BUILDING. SEE DETAIL 14/M5.1.

19mm PROPANE LINE DOWN THROUGH ROOF TO GAS-FIRED WATER HEATER 'WH'. FLASH AND SEAL AT ROOFPENETRATION WEATHER TIGHT. SEE DETAIL 14/M5.1.

TYPICAL PROPANE REGULATOR FROM 14 kPa (5 psi) BUILDING OPERATING PRESSURE TO PROPANE EQUIPMENTOPERATING PRESSURE.

MOUNT PROPANE LINE ON ROOF ON PLASTIC OR RUBBER SUPPORTS ON 2m (6ft) CENTERS. NO EXPOSEDSTYROFOAM.

HOT WATER RECIRC BALANCING BALL VALVES IN CEILING SPACE.

SEE MAIN FLOOR WATER & PROPANE PLAN 1/M3.2 FOR CONTINUATION OF 25mm SOFT COLD WATER LINE, 19mm HOTWATER LINE, AND 13mm HOT WATER RECIRC LINE UP HIGH AT U/S OF ROOF.

19mm HOT WATER LINE, 25mm SOFT COLD WATER LINE, AND 13mm HOT WATER RECIRC LINE DOWN FROM SECONDFLOOR CEILING SPACE CONCEALED IN WALL AND INTO MAIN FLOOR CEILING SPACE. SEE MAIN FLOOR WATER &PROPANE PLAN 1/M3.2 FOR CONTINUATION.

SEE MAIN FLOOR WATER & PROPANE PLAN 1/M3.2 FOR CONTINUATION OF 19mm - 14 kPa (5 psi) PROPANE LINE ALONGROOF.

SEE ENLARGED MECH ROOM PLAN 2/M3.3 FOR MORE DETAIL.

19mm COLD HARD WATER LINE DOWN CONCEALED IN WALL TO LOWER MAIN FLOOR CEILING SPACE. SEE MAIN FLOORWATER & PROPANE PLAN 1/M3.2 FOR CONTINUATION.

SEE MAIN FLOOR WATER & PROPANE PLAN 1/M3.2 FOR CONTINUATION OF 19mm COLD HARD WATER LINE ALONG U/SOF ROOF.

25mm COLD SOFT, 25mm HOT, AND 13mm PLASTIC FOOD GRADE RO WATER LINE DOWN CONCEALED IN WALL TOLOWER MAIN FLOOR CEILING SPACE. SEE MAIN FLOOR WATER & PROPANE PLAN 1/M3.2 FOR CONTINUATION.

32mm - 14 kPa (5 psi) PROPANE LINE CONTINUES ALONG ROOF. SEE MAIN FLOOR WATER AND PROPANE PLAN 1/M3.2FOR CONTINUATION.

32mm - 14 kPa (5 psi) PROPANE LINE UP ALONG EXTERIOR WALL ONTO ROOF. SUPPORT PROPANE LINE ALONG WALLWITH UNISTRUT CHANNELS AND CLAMPS ON 2m (6ft) CENTERS. SEE MAIN FLOOR WATER AND PROPANE PLAN 1/M3.2FOR CONTINUATION.

50mm CONDENSATE DRAIN DOWN FROM EVAPORATOR UNIT 'AC1' CONCEALED IN WALL TO MAIN FLOOR CEILINGSPACE.

PLUMBING KEYNOTES XX DENOTES KEYNOTE ON DWG

1

2

3

4

5

6

7

8

9

10

PLUMBING GENERAL NOTES

PLUMBING EQUIPMENT SCHEDULEJS - JANITORS SINKSUPPLY AND INSTALL A FIAT MOLDED STONE MOP SERVICE SINK MSB2424 MADE OF STAINPROOF MATERIALS W/ 255mm (10") HIGH WALLS MOLDED IN ONE PIECE. SINK TO BE C/WBUMPER GUARD, HOSE BRACKET, AND SEALANT. DRAIN TO BE FACTORY INSTALLED 302STAINLESS STEEL WITH COMBINATION DOME STRAINER AND LINT BASKET. FAUCET TO BETECK 28T2313 COMBINATION SUPPLY FITTING WITH HOSE END, VACUUM BREAKER, 70mm(2¾") MINI BLADE HANDLES, HEAVY C.P. BRASS P-TRAP, INTEGRAL STOPS, HEAVY DUTY"TUFF-TECK" STRUCTURES AND 2000mm (79") HOSE AND HANGER.CO - CLEANOUT (MEDIUM LOAD TRAFFIC - FINISHED AREAS)SUPPLY AND INSTALL A WADE MODEL 7000-R-1 FLOOR CLEANOUT C/W EPOXY COATED CASTIRON BODY W/ ANCHOR FLANGE, SECURED GASKETED SCORIATED COVER WITH 100mm (4")THREADED SHANK, AND HEAVY DUTY 150mm (6") ROUND ADJUSTABLE NICKEL BRONZECLEANOUT TOP. FOR WATER PROOFED AREAS PROVIDE FC FLANGE WITH FLASHING CLAMP.CO - CLEANOUT (UNFINISHED AREAS)SUPPLY AND INSTALL A WADE MODEL 7000-R-4 FLOOR CLEANOUT C/W EPOXY COATED CASTIRON BODY W/ ANCHOR FLANGE, SECURED GASKETED SCORIATED COVER WITH 100mm (4")THREADED SHANK, AND HEAVY DUTY 150mm (6") ROUND ADJUSTABLE NICKEL BRONZECLEANOUT TOP. FOR WATER PROOFED AREAS PROVIDE FC FLANGE WITH FLASHING CLAMP.RD1 - ROOF DRAIN #1SUPPLY AND INSTALL A WADE MODEL 3000-DF-42-52-53 100mm (4") EPOXY COATED CASTIRON LARGE AREA ROOF DRAIN W/ FLASHING CLAMP WITH INTEGRAL GRAVEL STOP, DECKCLAMP, AND METAL DOME STRAINER ALL TO SUIT STYLE OF ROOF AND INSULATIONTHICKNESS.RD2 - ROOF DRAIN #2SUPPLY AND INSTALL A WADE MODEL 3000-DF-42-52-53 150mm (6") EPOXY COATED CASTIRON LARGE AREA ROOF DRAIN W/ FLASHING CLAMP WITH INTEGRAL GRAVEL STOP, DECKCLAMP, AND METAL DOME STRAINER ALL TO SUIT STYLE OF ROOF AND INSULATIONTHICKNESS.RDO - ROOF DRAIN OUTLETSUPPLY AND INSTALL A JR SMITH MODEL 1771 250mm (10") NICKEL BRONZE DOWNSPOUTNOZZLE WITH FLANGE AND PRE-DRILLED COUNTER SUNK MOUNTING HOLES.FD1 - FLOOR DRAIN #1 (LIGHT DUTY)SUPPLY AND INSTALL A WADE MODEL 1000-C-R5 75mm (3") FLOOR DRAIN. ALL EPOXYCOATED CAST IRON BODY, CUSTOM ETCHED LOGO, TRAP GUARD, ANCHOR FLANGE W/SEEPAGE OPENINGS AND ADJUSTABLE ROUND HEAVY DUTY STAINLESS STEEL STRAINER.FD2 - FLOOR DRAIN #2 (HEAVY DUTY)SUPPLY AND INSTALL A WADE MODEL 1100-MR5-HD 75mm (3") FLOOR DRAIN. ON-GRADEEPOXY COATED CAST IRON BODY, CUSTOM ETCHED LOGO, TRAP GUARD, ANCHOR FLANGEW/ SEEPAGE OPENINGS AND ADJUSTABLE ROUND HEAVY DUTY STAINLESS STEELSTRAINER.PD - PIPE DRAINSUPPLY AND INSTALL A FIELD FABRICATED 75mm (3") PIPE DRAIN W/ TRAP. PROVIDE A100mm (4") COLLAR ON TOP OF DRAINS WHICH ARE LOCATED BENEATH REFRIGERATEDDISPLAY CASES AND HAVE MORE THAN ONE CONDENSATE DRAIN PIPED TO IT. SEE DETAIL4/M5.1.SHPD - SMOKEHOUSE PIPE DRAINSUPPLY AND INSTALL A ZURN MODEL Z1910 200mm x 200mm (8"x8") SANI-FLOR RECEPTOR OREQUAL. UNIT TO BE 200mm x 200mm (8"x8") AND 150mm (6") DEEP C/W MEDIUM DUTY GRATEWITH 7/16 SLOTTED OPENINGS, ACID RESISTANT PORCELAIN ENAMEL INTERIOR AND TOP,AND ABS ANTI-SPLASH INTERIOR BOTTOM DOME STRAINER. PROVIDE DEEP SEAL TRAP ATCONNECTION TO SANITARY SEWER LINE.TD1 - TRENCH DRAIN #1SUPPLY AND INSTALL AN ACO TRENCH DRAIN MODEL K100 PRECAST DRAINAGE CHANNEL.UNIT TO BE 1 METER LONG C/W 490Q HEAVY DUTY SLOTTED STAINLESS STEEL GRATE.PROVIDE DEEP SEAL TRAP AT CONNECTION TO SANITARY SEWER LINE.

11

12

13

15

16

SCALE: NTS3 WATER HEATER PIPING DETAIL

17

 1 : 1001 MEZZANINE PLAN

18

19

20

21

14

TD2 - TRENCH DRAIN #2SUPPLY AND INSTALL AN ACO TRENCH DRAIN MODEL K100 PRECAST DRAINAGE CHANNEL. UNITTO BE 2 METERS LONG C/W 490Q HEAVY DUTY SLOTTED STAINLESS STEEL GRATE. PROVIDEDEEP SEAL TRAP AT CONNECTION TO SANITARY SEWER LINE.TD3 - TRENCH DRAIN #3SUPPLY AND INSTALL AN ACO TRENCH DRAIN MODEL K100 PRECAST DRAINAGE CHANNEL. UNITTO BE 5 METERS LONG C/W 490Q HEAVY DUTY SLOTTED STAINLESS STEEL GRATE. PROVIDEDEEP SEAL TRAP AT CONNECTION TO SANITARY SEWER LINE.TD4 - TRENCH DRAIN #4SUPPLY AND INSTALL AN ACO TRENCH DRAIN MODEL K100 PRECAST DRAINAGE CHANNEL. UNITTO BE 6 METERS LONG C/W 490Q HEAVY DUTY SLOTTED STAINLESS STEEL GRATE. PROVIDEDEEP SEAL TRAP AT CONNECTION TO SANITARY SEWER LINE.GI1 & GI2 - GREASE INTERCEPTOR #1 & #2SUPPLY AND INSTALL A SCHIER PRODUCTS MODEL GB-50 GREASE INTERCEPTOR. UNIT TO BERECESSED IN FLOOR. UNIT CAPACITY IS TO BE 3.15 L/s (50 gpm) AND 113 kg (249 lbs) GREASEHOLDING CAPACITY C/W HIGH DENSITY POLYETHYLENE CONSTRUCTION, FIELD ADJUSTABLERISER SYSTEM, BUILT-IN FLOW CONTROL, BUILT-IN TEST CAPS, AND THREE OUTLET OPTIONS.POSITION GREASE INTERCEPTOR SO AS NOT TO CONFLICT WITH LEG SUPPORTS FORSINKS/TABLES. SEE DETAIL 5/M5.1.GI3, GI4 & GI5 - GREASE INTERCEPTOR #3, #4 & #5SUPPLY AND INSTALL A SCHIER PRODUCTS MODEL GB-35 GREASE INTERCEPTOR. UNIT TO BERECESSED IN FLOOR. UNIT CAPACITY IS TO BE 2.21 L/s (35 gpm) AND 64.4 kg (142 lbs) GREASEHOLDING CAPACITY C/W HIGH DENSITY POLYETHYLENE CONSTRUCTION, FIELD ADJUSTABLERISER SYSTEM, BUILT-IN FLOW CONTROL, BUILT-IN TEST CAPS, AND THREE OUTLET OPTIONS.POSITION GREASE INTERCEPTOR SO AS NOT TO CONFLICT WITH LEG SUPPORTS FORSINKS/TABLES. SEE DETAIL 5/M5.1.PC - PRODUCE DISPLAY CASESUPPLIED AND INSTALLED BY REFRIGERATION CONTRACTOR. MECHANICAL CONTRACTOR TOPIPE CONDENSATE DRAIN TO NEAREST PIPE DRAIN AND PROVIDE 13mm (½") RO WATER LINECONNECTION TO HUMIDIFIERS/MISTERS. CO-ORDINATE WITH REFRIGERATION CONTRACTOR.DSC - DELI SERVICE CASESUPPLIED AND INSTALLED BY REFRIGERATION CONTRACTOR. MECHANICAL CONTRACTOR TOPIPE CONDENSATE DRAIN TO NEAREST PIPE DRAIN AND PROVIDE 13mm (½") FILTERED WATERLINE CONNECTION TO HUMIDIFIER/MISTERS. CO-ORDINATE WITH REFRIGERATIONCONTRACTOR.MC - MEAT DISPLAY CASESUPPLIED AND INSTALLED BY REFRIGERATION CONTRACTOR. MECHANICAL CONTRACTOR TOPIPE CONDENSATE DRAIN TO NEAREST PIPE DRAIN AND PROVIDE 13mm (½") FILTERED WATERLINE CONNECTION TO HUMIDIFIER/MISTERS. CO-ORDINATE WITH REFRIGERATIONCONTRACTOR.MCC - MISTER CONTROL CENTERMISTER CONTROL CENTER PANEL SUPPLIED BY REFRIGERATION CONTRACTOR. INSTALLED ANDPLUMBED BY MECHANICAL CONTRACTOR.R - REFRIGERATED DISPLAY CASE, COOLER, OR FREEZERCONTRACTOR TO PROVIDE CONDENSATE DRAIN CONNECTION TO NEAREST PIPE DRAIN. CO-ORDINATE WITH REFRIGERATION CONTRACTOR.HB1 - INTERIOR HOSEBIB/WASHDOWN STATIONSUPPLY AND INSTALL A WOODFORD MODEL 26CP OR EQUAL STANDARD 13mm (½") HOSE BIBC/W VACUUM BREAKER, BACKFLOW PROTECTION, METAL WHEEL HANDLE, ROUGH BRASSFINISH, AND AUTOMATIC DRAIN. SEE DETAIL 2/M5.1.HB - EXTERIOR NON-FREEZE HOSE BIBSUPPLY AND INSTALL A WATTS MODEL HY-725 NON-FREEZE, KEY OPERATED WALL HYDRANT,NICKEL BRONZE BOX AND DOOR, CHROME PLATED HYDRANT FACE, INTEGRAL VACUUMBREAKER, ¾" (19mm) HOSE CONNECTION, ¾" (19mm) FEMALE x 1" (25mm) MALE PIPECONNECTION, ALL BRONZE HEAD, SEAT CASTING AND INTERNAL WORKING PARTS, BRONZEWALL CASING, AND LOOSE KEY.

HW - BARRIER FREE WATER CLOSET (BARRIER FREE FLUSH TANK, 4.8Lpf)SUPPLY AND INSTALL AN AMERICAN STANDARD "CHAMPION PRO" MODEL 211AA.154 LOW FLUSH,HIGH EFFICIENCY, ELONGATED RIM, BARRIER FREE WATER CLOSET OR EQUAL. UNIT TO BE C/W419mm (16½") HIGH BOWL, INSULATED TANK, 4.8 LITRES/FLUSH (1.07gpf), LEED QUALIFIED, FULLYGLAZED TRAPWAY, OVERSIZED 75mm FLUSH VALVE WITH CHEMICAL RESISTANT FLAPPER, ANDBOLT DOWN TANK COVER. SUPPLY TO BE TECK 47T316 RIGID/FLEX CLOSET SUPPLY WITHLOCKSHIELD ANGLE STOPS AND FLEXIBLE RISER. PROVIDE AMERICAN STANDARD MODEL5901.100 HEAVY DUTY OPEN FRONT SEAT LESS COVER.WC - TOILET - FLOOR MOUNTED TANK (4.8 Lpf)SUPPLY AND INSTALL AN AMERICAN STANDARD "CADET PRO" MODEL 3517C.101 LOW FLUSH,HIGH EFFICIENCY, ELONGATED RIM WATER CLOSET OR EQUAL. UNIT TO BE C/W INSULATEDTANK, 4.8 LITRES/FLUSH (1.07gpf), FULLY GLAZED TRAPWAY, AND BOLT-DOWN TANK COVER.SUPPLY TO BE TECK 47T316 RIGID/FLEX CLOSET SUPPLY WITH LOCKSHIELD ANGLE STOPS ANDFLEXIBLE RISER. PROVIDE AMERICAN STANDARD MODEL 5901.100 HEAVY DUTY OPEN FRONTSEAT LESS COVER.HV - BARRIER FREE COUNTER MOUNTED LAVATORY (HANDS-FREE FAUCET)SUPPLIED AND INSTALLED BY OTHERS C/W TRIM. MECHANICAL CONTRACTOR TO PROVIDE ½"HOT AND COLD WATER SUPPLIES. TRAP TO BE TECK 33T301, 32mm(1¼") CAST BRASS P-TRAP.WASTE TO BE TECK 33T290, 32mm(1¼") OFFSET BRASS OPEN GRID.V - COUNTER MOUNTED LAVATORY (MANUAL FAUCET)SUPPLIED AND INSTALLED BY OTHERS C/W TRIM. MECHANICAL CONTRACTOR TO PROVIDE ½"HOT AND COLD WATER SUPPLIES. TRAP TO BE TECK 33T301, 32mm(1¼") CAST BRASS P-TRAP.WASTE TO BE TECK 33T260, 32mm(1¼") BRASS OPEN GRID.HS1, HS2, HS3, HS4, HS5, HS6, HS7, HS8, HS9, HS10, & HS11 - HAND SINK #1, #2, #3, #4, #5, #6, #7,#8, #9, #10, & #11SUPPLY AND INSTALL AN ARISTALINE MODEL WHB 1819 STAINLESS STEEL WALL MOUNT SINKWITH 18-8 TYPE 16 GA. STAINLESS STEEL, SIDE WALL BRACKETS, AND WALL HANGER. SINK TOBE C/W SLOAN MODEL EBF-650 SENSOR ACTIVATED, BATTERY POWERED, 100mm (4")CENTERSET HAND WASHING FAUCET OR EQUAL. FAUCET TO PROVIDE 0.03 L/s (0.5gpm) C/WCHROME PLATED CAST BRASS FINISH, TEMPORARY-OFF FEATURE FOR CLEANING, SPLASH-PROOF CIRCUIT CONTROL MODULE, SENSOR RANGE ADJUSTMENT SCREW, LOW BATTERY LEDINDICATOR LIGHT, VARIABLE TIME OUT SETTINGS, SERVICEABLE FILTERED SOLENOID VALVE,BAK-CHEK TEE FOR HOT/COLD SUPPLY, VANDAL RESISTANT SPRAY HEAD WITH PRESSURECOMPENSATING FLOW CONTROL, METAL JACKETED WIRE PROTECTION FOR SENSOR LEAD,APPROPRIATE MOUNTING HARDWARE, 4 ALKALINE BATTERIES (2 YEAR LIFE), AND 0.03 L/s(0.5gpm) AERATED STREAM SPRAY INSERT. SUPPLY TO BE TECK 47T2512 RIGID/ANGLESUPPLIES WITH LOCKSHIELD STOPS AND FLEXIBLE RISERS. TRAP TO BE TECK 33T301 32mm(1¼") CAST BRASS P-TRAP. WASTE TO BE TECK 33T260 32mm (1¼") CAST BRASS OPEN GRID.HS8 & HS9 - HAND SINK #8 & #9HAND SINK SUPPLIED BY OTHERS COMPLETE WITH TRIM. CONTRACTOR TO INSTALL COMPLETEWITH 13mm (1/2") HOT AND COLD WATER SUPPLIES, 38mm (11/2") DRAIN WITH P-TRAP, ANDVENTING.S - COUNTER MOUNTED SINGLE COMPARTMENT SINKSINK TO BE SUPPLIED BY MILLWORK SUPPLIER COMPLETE WITH TRIM. CONTRACTOR TOINSTALL COMPLETE 13mm (½") HOT AND COLD WATER SUPPLIES WITH STOP AND 38mm (1½") P-TRAP WITH CLEANOUT.DIS - DISINFECTION SYSTEMCONTRACTOR TO PROVIDE 13mm (½") HOT WATER AND 13mm (½") COLD WATER CONNECTIONTO OWNER SUPPLIED ZEP DISINFECTION SYSTEM.MS - MEAT PREP SINKSINK TO BE SUPPLIED BY REFRIGERATION CONTRACTOR AND INSTALLED AND CONNECTED BYMECHANICAL CONTRACTOR C/W WATER SUPPLIES, VENT, P-TRAP, AND WASTE THROUGHGREASE INTERCEPTOR.SHS - SAUSAGE KITCHEN PREP SINKSINK TO BE SUPPLIED BY REFRIGERATION CONTRACTOR AND INSTALLED AND CONNECTED BYMECHANICAL CONTRACTOR C/W WATER SUPPLIES, VENT, P-TRAP, AND WASTE THROUGHGREASE INTERCEPTOR.

DS - DELI PREP SINKSINK TO BE SUPPLIED BY REFRIGERATION CONTRACTOR AND INSTALLED AND CONNECTED BYMECHANICAL CONTRACTOR C/W WATER SUPPLIES, VENT, P-TRAP, AND WASTE THROUGHGREASE INTERCEPTOR.CS - CHICKEN PREP SINKSINK TO BE SUPPLIED BY REFRIGERATION CONTRACTOR AND INSTALLED AND CONNECTED BYMECHANICAL CONTRACTOR C/W WATER SUPPLIES, VENT, P-TRAP, AND WASTE THROUGHGREASE INTERCEPTOR.BS - BAKERY SINKSINK TO BE SUPPLIED BY REFRIGERATION CONTRACTOR AND INSTALLED AND CONNECTED BYMECHANICAL CONTRACTOR C/W WATER SUPPLIES, VENT, P-TRAP, AND WASTE THROUGHGREASE INTERCEPTOR.SS - SUSHI PREP SINKSINK TO BE SUPPLIED BY REFRIGERATION CONTRACTOR AND INSTALLED AND CONNECTED BYMECHANICAL CONTRACTOR C/W WATER SUPPLIES, VENT, P-TRAP, AND WASTE THROUGHGREASE INTERCEPTOR.PS - PRODUCE SINKSINK TO BE SUPPLIED BY REFRIGERATION CONTRACTOR AND INSTALLED AND CONNECTED BYMECHANICAL CONTRACTOR C/W WATER SUPPLIES, VENT, P-TRAP, AND WASTE.IM - ICE MACHINESUPPLIED BY OWNERS. CONTRACTOR TO INSTALL C/W ½" PLASTIC FOOD GRADE RO WATERLINE AND INDIRECT DRAIN CONNECTION TO NEAREST PIPE DRAIN.WH - PROPANE-FIRED WATER HEATERSUPPLY AND INSTALL A BRADFORD WHITE MODEL EF-100T-199-3X(A) COMMERCIAL POWERDIRECT VENT PROPANE-FIRED WATER HEATER OR EQUAL. UNIT TO PROVIDE 58.56 kW (199.999MBH) HEATING INPUT, 378.5 L (100 US GAL) STORAGE CAPACITY, 904.7 L/h (239 gph) RECOVERYAT 38°C (100°F) TEMPERATURE RISE. UNIT TO BE C/W DIRECT SPARK IGNITION, T&P SAFETYRELIEF VALVE, DRAIN VALVE, MAGNESIUM ANODE RODS, ICON HD TEMPERATURE CONTROL,DIAGNOSTIC, AND SYSTEM IGNITION CONTROL BOARD W/ LCD DISPLAY, PREMIX POWER BURNER,SINGLE EXHAUST PRESSURE SWITCH, 75mm (3") VENT, AND 75mm (3") COMBUSTION AIR INTAKEUP THRU ROOF C/W CONCENTRIC VENT AND VERTICAL TERMINATION KITS. UNIT ELECTRICAL TOBE 115 VOLT, SINGLE PHASE. SEE DRAWING M2.2 FOR VENTILATION AND DETAIL 4/M3.3 FORPIPING SCHEMATIC.ET - POTABLE EXPANSION TANKSUPPLY AND INSTALL A WATTS MODEL PLT-20 POTABLE WATER EXPANSION TANK OR EQUAL.SEE DETAIL 4/M3.3.RP - HOT WATER RECIRCULATION PUMPSUPPLY AND INSTALL A BELL & GOSSET MODEL NBF-12 L/W BRONZE INLINE CIRCULATOR OREQUAL. UNIT TO PROVIDE 0.32 L/s @ 24 kPa (5 gpm @ 8 FT HEAD) C/W FRAC. H.P. MOTOR @1180rpm AND 115 VOLT, SINGLE PHASE. SEE DETAIL 4/M3.3 FOR PIPING SCHEMATIC.WS - WATER SOFTENERSUPPLY AND INSTALL A WATERGROUP MODEL TMI-120-11/2" OR EQUAL DUPLEX WATERSOFTENER. UNIT TO BE TWIN ALTERNATING TYPE WITH A 108,000 GRAIN CAPACITY PER TANK(216,000 GRAINS TOTAL) AT 10 LBS SALT PER CUBIC FOOT (40 LBS SALT PER REGENERATION),AND A 1.5"-9500 CONTROL VALVE 2 L/s @ 103kPa AND 2.78 L/s @ 172.37 kPa (32 GPM @ 15 PSIAND 44 GPM @ 25 PSI DROP), 0.11 m³ (4 ft³) OF RESIN PER TANK, AND BRINE TANK. UNITELECTRICAL TO BE 115 VOLT, SINGLE PHASE. SEE WATER TREATMENT ROOM PIPINGSCHEMATIC 16/M5.1.RO - REVERSE OSMOSIS MACHINESUPPLIED BY OTHERS. CONTRACTOR TO INSTALL WITH WATER SUPPLY AND DRAINCONNECTIONS AS PER WATER TREATMENT PIPING SCHEMATIC 16/M5.1.SP - SUMP PUMPSUPPLY AND INSTALL A HYDROMATIC MODEL SPD 50 AH1 SUBMERSIBLE SUMP PUMP OR EQUAL.UNIT TO PUMP 170.3 L/min @ 95.65 kPa (45 GPM @ 32 FEET OF HEAD) COMPLETE WITH A ½ H.P.MOTOR @ 3450 RPM. UNIT TO BE COMPLETE WITH AUTOMATIC OPERATION, DIAPHRAMPRESSURE SWITCH, 50mm (2") DISCHARGE VALVE, DISCHARGE CHECK VALVE, AND WATERRESISTANT POWER CORD WITH MOLDED PLUG.

WPB - WATER PRESSURE BOOSTER SYSTEMSUPPLY AND INSTALL A POTABLE PRESSURE BOOSTER SYSTEM TO BE A GRUNDFOS EZ BOOSTSYSTEM WITH BMQU BOOSTER PUMP, TANK AND CONTROLLER. UNIT TO BE MODEL 30BMQE 10C-130 TO PROVIDE 151.4 L/min @ 275.8 kPa (40 GPM @ 40 PSI) BOOST PRESSURE WITH A 1 HPMOTOR AT 208 VOLT, SINGLE PHASE. UNIT TO BE COMPLETE WITH STAINLESS STEELSLEEVE/TANK, MSE3 MOTOR, EZ BOOST VARIABLE SPEED CONTROLLER, PRESSURE SENSORKIT, 2 GALLON STAINLESS STEEL/POLYPROPYLENE LINED DIAPHRAGM TANK, AND WALLMOUNTING BRACKETS. UNIT ELECTRICAL TO BE 208 VOLT, SINGLE PHASE, WITH A RATEDCURRENT OF 9.5 AMPS AND A LOCKED MOTOR CURRENT OF 11.1 AMPS. SEE DETAIL 9/M5.1.CF - CALCITE FILTERSUPPLIED AND INSTALLED BY OWNER'S WATER TREATMENT SYSTEM SUPPLIER.PW - PAN WASHERSUPPLIED BY OWNERS. CONTRACTOR TO INSTALL C/W 38mm (1½") INDIRECT DRAIN CONNECTIONTO PIPE DRAIN AND 19mm (¾") HOT WATER AND 13mm (½") COLD WATER CONNECTION C/WPRESSURE REDUCING VALVES AS PER MANUFACTURER'S SPECIFICATIONS.COM - COMBI OVENSUPPLIED BY OTHERS. MECHANICAL CONTRACTOR TO INSTALL C/W PROPANE ROUGH-IN WITHSHUT-OFF VALVE AND STAINLESS STEEL FLEX CONNECTION TO COMBI OVEN. PROVIDE COPPERINDIRECT DRAIN TO NEAREST PIPE DRAIN (DO NOT USE ABS) AND 19mm (¾") SOFT COLD WATERCONNECTION AS PER MANUFACTURER'S REQUIREMENTS. PIPE DRAIN LINE TO BE STEAM GRADEPVC OR CAST IRON FOR A DISTANCE OF 3m (10ft) FROM THE PIPE DRAIN DUE TO HIGHTEMPERATURE. DO NOT USE ABS. SEE DRAWING M2.1 FOR VENTILATION.RET - RETARDER PROOFERBAKERY RETARDER PROOFER TO BE SUPPLIED BY OTHERS. PROVIDE FLOOR DRAIN, 13mm (½")SOFT COLD WATER CONNECTION AND INDIRECT DRAIN CONNECTION TO NEAREST PIPE DRAIN.PIPE DRAIN LINE TO BE STEAM GRADE PVC OR CAST IRON FOR A DISTANCE OF 3m (10ft) FROMTHE PIPE DRAIN DUE TO HIGH TEMPERATURE. DO NOT USE ABS.O - RACK OVENHOBART RACK OVEN BY OTHERS. CONTRACTOR TO PROVIDE PROPANE ROUGH-IN WITH SHUTOFF VALVE AND STAINLESS STEEL FLEX CONNECTION. ALSO PROVIDE 13mm (½") COLD SOFTWATER CONNECTION AND INDIRECT DRAIN CONNECTION TO NEAREST PIPE DRAIN. PIPE DRAINLINE TO BE STEAM GRADE PVC OR CAST IRON FOR A DISTANCE OF 3m (10ft) FROM THE PIPEDRAIN DUE TO HIGH TEMPERATURE. DO NOT USE ABS. REFER TO DRAWING M2.1 FORVENTILATION.SM - MEAT SMOKER MACHINEMEAT SMOKER SUPPLIED BY OTHERS. CONTRACTOR TO CONNECT MEAT SMOKER TO PIPEDRAIN THRU GREASE TRAP AND PROVIDE 150mmØ (6"Ø) STAINLESS STEEL TYPE L VENT UPTHROUGH ROOF WITH 25mm (1") DRAIN FROM VENT TO PIPE DRAIN. ALSO PROVIDE 13mm (½")FILTERED COLD WATER LINE, 6mm (¼") HOT WATER CONNECTION TO INDUCT RINSE, 6mm (¼")HOT WATER CONNECTION TO INDUCT WASH, 13mm (½") COLD WATER CONNECTION FOR FIRESAFETY, AND 25mm (1") INDIRECT DRAIN CONNECTION TO PIPE DRAIN 'SHPD'. SEE DETAIL X/M5.1.WM - WATER MARKETSUPPLIED BY OTHERS. CONTRACTOR TO INSTALL WITH 19mm (¾") PLASTIC FOOD GRADE ROWATER CONNECTION AND INDIRECT DRAIN CONNECTION TO PIPE DRAIN.RTU1, RTU2, RTU3, RTU4, RTU5, RTU6, RTU7 & RTU8 - ROOF TOP UNITS #1, #2, #3, #4, #5, #6, #7& #8SEE DRAWING M2.2 FOR SPECIFICATIONS.UH1, UH2, UH3 & UH4 - PROPANE UNIT HEATERS #1, #2, #3 & #4SEE DRAWING M2.2 FOR SPECIFICATIONS.

 1 : 502 ENLARGED MECH ROOM PLAN1 BID SET 2016-10-17