19
Insist on an ActronAir specialist
Every home is different and your ActronAir specialist will
advise you on the best configuration to suit your lifestyle.
An ActronAir specialist is also qualified to install your
air conditioning system quickly and safely and provide
the best ongoing service should you need maintenance,
spare parts or advice.
Warranty
Comfort you can depend on.
ActronAir is an Australian owned and managed company.
So you’ll never have to look far for spare parts or product
support, especially with the ActronAir National Service
Network providing quick and reliable service where and
when it’s needed.
A substantial 5-year residential warranty provides even
more peace of mind.
“Cool.”
20
™
Energy Smart Performance™
The ActronAir reverse cycle system keeps
your home comfortable all year round,
keeping you cool by removing heat
and humidity in summer and switching
effortlessly to warm you in winter. � Capacity Range Available from 9 - 25 kW
� Single and Three Phase Models available
� Reverse cycle ducted split system
� Fixed speed – 100% capacity operation
� A Direct drive Three Speed Indoor Fan
� Superior operating range up to 50°C DB cooling and -10°C DB heating
� Easy to operate controller with 24-hour timer
� Fully integrated 8-zone control
� Zoning capability up to 8 zones
� Manual inputs available for 3rd party control
� Louvre grille protection
� Vertical condenser air discharge available from 11 - 25 kW
� Powder coated outdoor panels to withstand 1000-hour salt spray exposure AS/NZS 4506:2005
� Adaptive Demand Defrost for better heating comfort in Extreme winter conditions
� MEPS April 2011, QLD MP 4.1 and SA compliant
Gain even more comfort.
ESP Sophisticated micro-technology
achieves faster, more precise temperature
control and energy savings. � Capacity Range Available from 11 - 19 kW
� Single and Three Phase Models available
� Reverse cycle ducted split system
� Variable capacity digital scroll compressor 10 to 100% operation
� A Direct drive Three Speed Indoor Fan
� Superior operating range up to 50°C DB cooling and -10°C DB heating
� Easy to operate 7-day programmable controller with 24-hour timer
� Fully integrated 8-zone control
� Zoning capability up to 8 zones
� Manual inputs available for 3rd party on/off control
� Louvre grille protection
� Vertical condenser air discharge
� Powder coated outdoor panels to withstand 1000-hour salt spray exposure AS/NZS 4506:2005
� Adaptive Demand Defrost for better heating comfort in Extreme winter conditions
� MEPS April 2011, QLD MP 4.1 and SA compliant
� Quick and precise temperature control
� Sound Reduction System (SRS)
� Three phase sequence relay
Gain even more energy savings. ESP Plus’s
Indoor Smart Fan Upgrade gives you
advanced air flow control and can save up
to 85% on indoor fan power consumption
when zoning. � Capacity Range Available from 11 - 22 kW
� Single and Three Phase Models available
� Award winning Reverse cycle ducted split system
� Variable capacity digital scroll compressor 10 to 100% operation
� High efficiency ECM Variable Speed indoor fan
� Superior operating range up to 50°C DB cooling and -10°C DB heating
� Easy to operate 7-day programmable controller with 24-hour timer
� Fully integrated 8-zone control
� Zoning capability up to 8 zones
� Manual inputs available for 3rd party on/off control
� Louvre grille protection
� Vertical condenser air discharge
� Powder coated outdoor panels to withstand 1000-hour salt spray exposure AS/NZS 4506:2005
� Adaptive Demand Defrost for better heating comfort in Extreme winter conditions
� MEPS April 2011, QLD MP 4.1 and SA compliant
� Quick and precise temperature control
� Sound Reduction System (SRS)
� Three phase sequence relay
� Quiet start indoor smart fan system
� Variable Fan Technology (VFT) to deliver improved energy efficiency and lower indoor noise
ESP Ultima takes you beyond comfort and
Energy saving with the ultimate comfort
control system in Australia. Individual Zone
Control lets you create temperature settings
in up to 8 different areas of your home. � Capacity Range Available from 14 - 22 kW
� Single and Three Phase Models available
� Incorporates the energy efficient design features of the award winning ESP Plus reverse cycle ducted split system
� Variable capacity digital scroll compressor 10 to 100% operation
� High efficiency ECM Variable Speed indoor fan
� Superior operating range up to 50°C DB cooling and -10°C DB heating
� Easy to operate 7-day programmable controller with 24-hour timer
� Fully integrated 8-zone control
� Zoning capability up to 8 zones
� Manual inputs available for 3rd party on/off control
� Louvre grille protection
� Vertical condenser air discharge
� Powder coated outdoor panels to withstand 1000-hour salt spray exposure AS/NZS 4506:2005
� Adaptive Demand Defrost for better heating comfort in Extreme winter conditions
� MEPS April 2011, QLD MP 4.1 and SA compliant
� Quick and precise temperature control
� Sound Reduction System (SRS)
� Three phase sequence relay
� Quiet start indoor smart fan system
� Variable Fan Technology (VFT) to deliver improved energy efficiency and lower indoor noise
� Variable Air Volume (VAV) technology to deliver individual temperature zone control
� Individual zone control to set up to 8 different temperatures for up to 8 zones
� Optional secondary sensors for large, open plan rooms and sensor only zones
21
Classic Split Ducted Standard Cycling
Technical InformationSingle Phase
OUTDOOR MODEL SRE091C SRA101C SRA121C SRA141C SRA161CINDOOR MODEL SRG091E SRA101E SRA120E SRA140E SRA160ENett (Rated) Capacity (kW)(AS/NZS3823.1.2)
Cooling 9.00 10.00 11.50 14.50 16.40Heating 8.50 10.25 12.00 15.00 17.40
Input Power (kW) (AS/NZS3823.1.2)
Cooling 2.77 3.33 3.90 4.82 5.65Heating 2.43 3.20 3.58 4.34 5.37
(1) EER Rated (AS/NZS3823.1.2) Cooling 3.25 3.00 2.95 3.01 2.90(2) COP Rated (AS/NZS3823.1.2) Heating 3.50 3.20 3.35 3.46 3.24
Power Supply - 50HzOutdoor 230 - 240V / 1Ph + NIndoor 230 - 240V / 1Ph + N
Rated Amps (AS/NZS3823.1.2) Outdoor / Indoor / Total 9.5 / 2.8 / 12.3 11.6 / 2.1 / 13.7 16.1 / 2.6 / 18.7 18.7 / 2.9 / 21.6 21.2 / 3.3 / 24.5(3) Circuit Breaker Amps (Suggested) 20.0 25.0 32.0Compressor Type ScrollRefrigerant R410aIndoor Fan Type 3 Speed
Airflow Indoor (l/s)Maximum 520 575 820 886 972Nominal 450 500 670 770 845Minimum 380 425 536 655 718
Outdoor Dimensions (mm)Depth 370 535 580Height 805 940 990Width 1000 1245 1320
Indoor Dimensions (mm)Depth 595 615 615Height 412 412 412Width 850 1090 1290
Nominal Weight (kgs)Outdoor 83 119 123 137 146Indoor 41 41 50 55 60
(4) Sound Pressure Level (dBA)(5) Sound Power Level (dBA)
Outdoor (low/high fan) 50 / 52 47 / 50 47 / 50 50 / 52 50 / 52Outdoor (low/high fan) 67 / 69 64 / 67 64 / 67 67 / 69 67 / 69
MEPS Certified Yes Yes Yes Yes Yes(6) QLD Development Code MP4.1 Compliant Yes Yes Yes Yes YesSA Min Energy Standards Compliant Yes Yes Yes Yes Yes(7) EER Tested (AS/NZS3823.2) 3.21 2.96 2.93 2.95 3.04
Control FeaturesAM24-8Z Wall Controller (8 Zone) Included Included Included Included IncludedAM7-8Z Wall Controller (8 Zone) Optional Optional Optional Optional OptionalHome Automation ON / OFF Capability Yes Yes Yes Yes YesManual Inputs Capable for Third Party Control Optional Yes Yes Yes YesRemote Temperature Sensor Optional Optional Optional Optional OptionalSecondary Master Controller Optional Optional Optional Optional Optional(8) Maximum Number of Zones 8 8 8 8 8Compressor Soft Start Yes Yes Yes Yes Yes
Control FeaturesAM24-8Z Wall Controller (8 Zone) Included Included Included Included Included IncludedAM7-8Z Wall Controller (8 Zone) Optional Optional Optional Optional Optional OptionalHome Automation ON / OFF Capability Yes Yes Yes Yes Yes YesManual Inputs Capable for Third Party Control Yes Yes Yes Yes Yes YesRemote Temperature Sensor Optional Optional Optional Optional Optional OptionalSecondary Master Controller Optional Optional Optional Optional Optional Optional(8) Maximum Number of Zones 8 8 8 8 8 8Compressor Soft Start Optional Optional Optional Optional Optional Optional
Technical InformationThree Phase
OUTDOOR MODEL SRA120C SRA140C SRA160C SRA190C SRA230C SRA260CINDOOR MODEL SRA120E SRA140E SRA160E SRA190E SRA230E SRA260ENett (Rated) Capacity (kW)(AS/NZS3823.1.2)
Cooling 11.10 14.50 16.40 18.20 22.50 24.00Heating 11.70 15.00 17.40 19.20 23.00 25.50
Input Power (kW)(AS/NZS3823.1.2)
Cooling 3.67 4.82 5.62 6.24 7.14 7.65Heating 3.38 4.34 5.30 5.68 6.67 7.55
(1) EER Rated (AS/NZS3823.1.2)(2) COP Rated (AS/NZS3823.1.2)
Cooling 3.02 3.01 2.92 2.92 3.15 3.14Heating 3.46 3.46 3.28 3.38 3.45 3.38
Power Supply - (V / Ph / Hz)Outdoor 400 - 415V / 3Ph + N / 50HzIndoor 230 - 240V / 1Ph + N / 50Hz
Rated Amps (AS/NZS3823.1.2) Outdoor/Indoor/Total 5.9 / 2.9 / 8.8 7.9 / 2.9 / 10.8 8.3 / 3.3 / 11.6 10.2 / 3.2 / 13.4 13.5 / 4.4 / 17.9 13.7 / 4.6 / 18.3(3) Circuit Breaker Amps (Suggested) 16.0 20.0 20.0 20.0 25.0 25.0Compressor Type / No. per Unit ScrollRefrigerant R410aIndoor Fan Type Indoor 3 Speed
Airflow Indoor (l/s)Maximum 820 886 972 1150 1380 1452Nominal 670 770 845 950 1200 1320Minimum 536 655 718 810 1020 1122
Outdoor Dimensions (mm)Depth 535 580 580 580 685Height 940 990 990 1040 1105Width 1245 1320 1320 1460 1685
Indoor Dimensions (mm)Depth 615 615 680 695Height 412 412 435 485Width 1090 1290 1420 1470
Nominal Weight (kgs)Outdoor 120 135 145 175 200 245Indoor 50 55 60 75 90 90
(4) Sound Pressure Level (dBA)(5) Sound Power Level (dBA)
Outdoor (low/high fan) 47 / 50 50 / 52 50 / 52 52 / 54 55 / 59 55 / 59Outdoor (low/high fan) 64 / 67 67 / 69 67 / 69 69 / 71 71 / 75 71 / 75
MEPS Certified Yes Yes Yes Yes Yes Yes(6) QLD Development Code MP4.1 Compliant Yes Yes Yes Yes Yes YesSA Min Energy Standards Compliant Yes Yes Yes Yes Yes Yes(7) EER Tested (AS/NZS3823.2) 3.01 2.92 2.91 2.94 3.13 3.12
22
ESP Split Ducted Variable Capacity
Energy Smart Performance™
Technical InformationSingle Phase Three Phase
OUTDOOR MODEL SRD125C SRD151C SRD175C SRD160C SRD190CINDOOR MODEL SRD125E SRD151E SRD175E SRD160E SRD190E
Nett (Rated) Capacity (kW)(AS/NZS3823.1.2)
Cooling (min - max) 11.75 (1.18-11.75)
14.50 (1.45-14.50)
17.75 (1.78-17.75)
16.40 (1.64-16.40)
18.60 (1.86-18.60)
Heating (min - max) 12.50 (2.38-12.50)
14.75 (2.80-14.75)
18.25 (3.47-18.25)
17.40 (3.31-17.40)
19.60 (3.72-19.60)
Input Power (kW)(AS/NZS3823.1.2)
Cooling 3.85 4.75 6.02 5.47 6.20Heating 3.67 4.21 5.57 5.19 5.89
(1) EER Rated (AS/NZS3823.1.2)(2) COP Rated (AS/NZS3823.1.2)
Cooling 3.05 3.05 2.95 3.00 3.00Heating 3.40 3.50 3.28 3.35 3.33
Power Supply - (V / Ph / Hz)Outdoor 230 - 240V / 1Ph + N / 50Hz 400 - 415V / 3Ph + N / 50Hz Indoor 230 - 240V / 1Ph + N / 50Hz
Rated Amps (AS/NZS3823.1.2) Outdoor / Indoor / Total 15.4 / 3.0 / 18.4 18.4 / 3.0 / 21.4 22.0 / 3.0 / 25.0 9.3 / 3.2 / 12.5 9.5 / 3.5 / 13.0(3) Circuit Breaker Amps (Suggested) 25.0 32.0 40.0 20.0 20.0Compressor Type / No. per Unit Digital Scroll / 1Refrigerant R410a
Fans (Type x Number per unit)Outdoor Axial / 6 Pole External Rotor / Direct Drive x 2Indoor Twin Deck Centrifugal / 4 Pole / Direct Drive x 1
Airflow Range Indoor (l/s)Maximum 820 950 1100 975 1150Nominal 650 820 920 845 950Minimum 520 650 740 675 760
Outdoor Dimensions (mm)Depth 580 580 580 580 580Height 990 990 1040 990 1040Width 1320 1320 1460 1320 1460
Indoor Dimensions (mm)Depth 615 615 680 615 680Height 412 412 435 412 435Width 1090 1290 1420 1290 1420
Nominal Weight (kgs)Outdoor 136 138 180 146 185Indoor 56 60 75 61 75
(4) Sound Pressure Level (dBA)(5) Sound Power Level (dBA)
Outdoor (low/high fan) 47 / 50 50 / 52 52 / 54 50 / 52 52 / 54Outdoor (low/high fan) 64 / 67 67 / 69 69 / 71 67 / 69 69 / 71
MEPS Certified Yes Yes Yes Yes Yes(6) QLD Development Code MP4.1 Compliant Yes Yes Yes Yes YesSA Min Energy Standards Compliant Yes Yes Yes Yes Yes(7) EER Tested (AS/NZS3823.2) 2.90 3.12 2.90 2.92 3.07
Control FeaturesLM7-D Wall Controller (8 Zone)* Included Included Included Included IncludedLM24 Wall Controller (8 Zone)* Optional Optional Optional Optional OptionalHome Automation ON / OFF Capability Yes Yes Yes Yes YesManual Inputs Capable for Third Party Control Optional Optional Optional Optional OptionalRemote Temperature Sensor Optional Optional Optional Optional OptionalSecondary Master Controller Optional Optional Optional Optional Optional(8) Maximum Number of Zones 8 8 8 8 8Compressor Soft Start Yes Yes Yes Optional Optional
ESP Plus Split Ducted Variable Capacity
Technical InformationSingle Phase Three Phase
OUTDOOR MODEL SRD125C SRD151C SRD175C SRD160C SRD190C SRD230CINDOOR MODEL SRV125E SRV151E SRV175E SRV160E SRV190E SRV230E
Nett (Rated) Capacity (kW)(AS/NZS3823.1.2)
Cooling (min - max) 12.25 (1.23-12.25)
14.50 (1.45-14.50)
18.00 (1.80-18.00)
16.60 (1.66-16.60)
18.90 (1.89-18.90)
23.00 (2.30-23.00)
Heating (min - max) 12.25 (2.33-12.25)
14.75 (2.80-14.75)
18.00 (3.42-18.00)
17.40 (3.31-17.40)
19.30 (3.67-19.30)
23.50 (4.47-23.50)
Input Power (kW)(AS/NZS3823.1.2)
Cooling 3.83 4.53 5.90 5.36 5.90 6.76Heating 3.50 4.28 5.30 4.90 5.62 6.91
(1) EER Rated (AS/NZS3823.1.2)(2) COP Rated (AS/NZS3823.1.2)
Cooling 3.20 3.20 3.05 3.10 3.20 3.40Heating 3.50 3.45 3.40 3.55 3.44 3.40
Power Supply - (V / Ph / Hz)Outdoor 230 - 240V / 1Ph + N / 50Hz 400 - 415V / 3Ph + N / 50Hz Indoor 230 - 240V / 1Ph + N / 50Hz
Rated Amps (AS/NZS3823.1.2) Outdoor / Indoor / Total 15.4 / 2.8 / 18.2 18.4 / 2.4 / 20.8 22.1 / 4.0 / 26.1 9.2 / 5.1 / 14.3 9.5 / 3.0 / 12.5 14.0 / 4.0 / 18.0(3) Circuit Breaker Amps (Suggested) 25.0 32.0 40.0 20.0 20.0 25.0Compressor Type / No. per Unit Digital Scroll / 1Refrigerant R410a
Fans (Type x Number per unit) Outdoor Axial / 6 Pole External Rotor / Direct Drive x 2Indoor Twin Deck Centrifugal / 4 Pole / EC Direct Drive x 1
Airflow Range Indoor (l/s)Maximum 820 910 1100 1000 1150 1440Nominal 650 760 920 845 950 1200Minimum 130 150 185 170 200 240
Outdoor Dimensions (mm)Depth 580 580 580 580 580 685Height 990 990 1040 990 1040 1105Width 1320 1320 1460 1320 1460 1685
Indoor Dimensions (mm)Depth 615 615 680 615 680 695Height 412 412 435 412 435 485Width 1090 1290 1420 1290 1420 1470
Nominal Weight (kgs)Outdoor 136 138 180 146 185 220Indoor 57 61 76 62 76 90
(4) Sound Pressure Level (dBA)(5) Sound Power Level (dBA)
Outdoor (low/high fan) 47 / 50 50 / 52 52 / 54 50 / 52 52 / 54 54 / 59Outdoor (low/high fan) 64 / 67 67 / 69 69 / 71 67 / 69 69 / 71 70 / 75
MEPS Certified Yes Yes Yes Yes Yes Yes(6) QLD Development Code MP4.1 Compliant Yes Yes Yes Yes Yes YesSA Min Energy Standards Compliant Yes Yes Yes Yes Yes Yes(7) EER Tested (AS/NZS3823.2) 3.19 3.25 2.99 2.96 3.23 3.33
Control FeaturesLM7-D Wall Controller (8 Zone)* Included Included Included Included Included Included
LM24 Wall Controller (8 Zone)* Optional Optional Optional Optional Optional Optional
Home Automation ON / OFF Capability Yes Yes Yes Yes Yes YesManual Inputs Capable for Third Party Control Optional Optional Optional Optional Optional OptionalRemote Temperature Sensor Optional Optional Optional Optional Optional OptionalSecondary Master Controller Optional Optional Optional Optional Optional Optional(8) Maximum Number of Zones 8 8 8 8 8 8Compressor Soft Start Yes Yes Yes Optional Optional Optional
23
Refrigerant Trading Authorisation No.: AU06394
ESP Ultima Split Ducted Variable Capacity
™
18° 20° 22°
Technical InformationSingle Phase Three Phase
OUTDOOR MODEL SRD151C SRD175C SRD160C SRD190C SRD230CINDOOR MODEL SRM151E SRM175E SRM160E SRM190E SRM230ENett (Rated) Capacity (kW)(AS/NZS3823.1.2)
Cooling (min - max) 14.50 (1.45-14.50) 18.00 ( 1.80-18.00) 16.60 (1.66-16.60) 18.90 (1.89-18.90) 23.00 (2.30-23.00)Heating (min - max) 14.75 (2.80-14.75) 18.00 (3.42-18.00) 17.40 (3.31-17.40) 19.30 (3.67-19.30) 23.50 (4.47-23.50)
Input Power (kW)(AS/NZS3823.1.2)
Cooling 4.53 5.90 5.36 5.90 6.76Heating 4.28 5.30 4.90 5.62 6.91
(1) EER Rated (AS/NZS3823.1.2)(2) COP Rated (AS/NZS3823.1.2)
Cooling 3.20 3.05 3.10 3.20 3.40Heating 3.45 3.40 3.55 3.44 3.40
Power Supply - (V / Ph / Hz)Outdoor 230 - 240V / 1Ph + N / 50Hz 400 - 415V / 3Ph + N / 50HzIndoor 230 - 240V / 1Ph + N / 50Hz
Rated Amps (AS/NZS3823.1.2) Outdoor/Indoor/Total 18.4 / 2.4 / 20.8 22.1 / 4.0 / 26.1 9.2 / 5.1 / 14.3 9.5 / 3.0 / 12.5 14.0 / 4.0 / 18.0(3) Circuit Breaker Amps (Suggested) 32.0 40.0 20.0 20.0 25.0Compressor Type / No. per Unit Digital Scroll / 1Refrigerant R410a
Fans (Type x Number per unit)Outdoor Axial / 6 Pole External Rotor / EC Direct Drive x 2Indoor Twin Deck Centrifugal / 4 Pole / EC Direct Drive x 1
Airflow Range Indoor (l/s)Maximum 910 1100 1000 1150 1440Nominal 760 920 845 950 1200Minimum 150 185 170 200 240
Outdoor Dimensions (mm)Depth 580 580 580 580 685Height 990 1040 990 1040 1105Width 1320 1460 1320 1460 1685
Indoor Dimensions (mm)Depth 615 680 615 680 695Height 412 435 412 435 485Width 1290 1420 1290 1420 1470
Nominal Weight (kgs)Outdoor 138 180 146 185 220Indoor 61 76 62 76 90
(4) Sound Pressure Level (dBA)(5) Sound Power Level (dBA)
Outdoor (low/high fan) 50 / 52 52 / 54 50 / 52 52 / 54 54 / 59Outdoor (low/high fan) 67 / 69 69 / 71 67 / 69 69 / 71 70 / 75
MEPS Certified Yes Yes Yes Yes Yes(6) QLD Development Code MP4.1 Compliant Yes Yes Yes Yes Yes SA Min Energy Standards Compliant Yes Yes Yes Yes Yes (7)EER Tested (AS/NZS3823.2) 3.25 2.99 2.96 3.23 3.33
Control FeaturesLM7-D Wall Controller (8 Zone)* Included Included Included Included IncludedLM24 Wall Controller (8 Zone)* Optional Optional Optional Optional OptionalHome Automation ON / OFF Capability Yes Yes Yes Yes YesManual Inputs Capable for Third Party Control Optional Optional Optional Optional OptionalRemote Temperature Sensor Optional Optional Optional Optional OptionalSecondary Master Controller Optional Optional Optional Optional Optional(8) Maximum Number of Zones 8 8 8 8 8Compressor Soft Start Yes Yes Optional Optional Optional
Operating Range:
Cooling: 15ºC DB to 50ºC DB Outdoor / Air Entering Indoor 29ºC DB. Heating: -10ºC DB to 21ºC DB Outdoor / Air Entering Indoor 21ºC DB.
Foot Notes
1. EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling¸ Rated Input Power Cooling)
2. COP Rated = Coefficient of Performance (Rated Capacity Heating¸ Rated Power Heating)
3. Recommended circuit breaker size. This should be used as a guide only, refer to AS/NZS 3000 "Australian/New Zealand Wiring Rules" for more details.
4. Sound Pressure Level at 3m distance is determined as the measured sound pressure at 3m perpendicular to the coil side of the condenser.
5. Determination of Sound Power Levels of Noise Sources, AS1217.2 - Precision Methods for Broad-Band Sources in Reverberation Rooms.
6. Complies with SA MEPS and QLD Development Code MP4.1 minimum tested EER of 2.9 for Class 1 and Class 2 buildings from 1st September 2009. See www.dip.qld.gov.au.
7. EER Tested = (Tested Capacity Cooling¸ Tested Input Power Cooling). For more information refer to www.energyrating.gov.au
8. Maximum number of zones using an 8 zone controller. This may need to be purchased separately.
When the outdoor temperature exceeds the rated conditions, the cooling/heating capacities may decrease below the rated nett values.
Specifications subject to change without notice.
5 year residential warranty - refer to Terms of Warranty document for full details or visit www.actronair.com.au
CoolWorld Award
ESP Plus has been recognised by the air conditioning industry
with the inaugural COOLWorld Award. This prestigious trophy
acknowledges an ability to significantly and measurably reduce
the impact of air conditioning on the environment.
Warranty
* Wall controller LM7-D & LM24 will be available from December 2011.
N2018
All systems specified in this brochure pass or exceed minimum government efficiency levels when tested to AS/NZS 2011.2 Amdt 3-2008 at rated capacity.
MEPSC E R T I F I E D
24
“ ActronAir is not only one of the most effective, energy efficient and quiet ducted reverse cycle air conditioning systems in Australia, it’s one of the best in the world.”
25
26
0500
-126
10
-201
1 ©
Cop
yrig
ht 2
011.
www.actronair.com.au
ActronAir® Head Office, 5 Irvine Place, Bella Vista NSW 2153
Ph: 1300 522 722