15_ Staehelin, Varian Technology Update - TrueBeam

Embed Size (px)

Citation preview

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    1/48

    1 |  VARIAN ONCOLOGY SYSTEMS 

    VARIAN

    ONCOLOGY

    SYSTEMS

    TRUEBEAM™ - ADVANCEDTECHNOLOGY UPDATE

    Varian Medical Systems International AG

    Bangkok – August 24, 2012

    Rolf B Staehelin

    Director International Marketing

     August 24, 2012

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    2/48

    2 |  VARIAN ONCOLOGY SYSTEMS 

     ARIA™ 

    Oncology

    Information

    System

    Eclipse™ 

    Treatment

    Planning

    System

    Clinac®

    Innovative

    Treatment

    Platform

    UNIQUE™ 

    Cost-Effective

    Oncology

    Solution

    ProBeam™ 

    Fully-integrated

    Proton TherapySystem

    Varian BrachyTherapy 

    Product Suite for

    Planning &

    Delivery

    TrueBeam™ 

    Treatment Procedures with

    Exceptional Ease, Speed

    and Accuracy

    Novalis Tx®

    Neurosurgical &

    Radiosurgical Applications

    Trilogy™ 

     All in One

    Treatment

    System

    The Varian Oncology Solution Advantage 

    http://localhost/var/www/apps/conversion/tmp/scratch_1/03%20-%20SRS%20short.pptxhttp://localhost/var/www/apps/conversion/tmp/scratch_1/04%20-%20BT%20short.pptxhttp://localhost/var/www/apps/conversion/tmp/scratch_1/05%20-%20PTB%20short.pptxhttp://localhost/var/www/apps/conversion/tmp/scratch_1/02%20-%20RT%20short.pptxhttp://localhost/var/www/apps/conversion/tmp/scratch_1/14%20-%20Trilogy%20short.pptxhttp://localhost/var/www/apps/conversion/tmp/scratch_1/15%20-%20Novalis%20Tx%20short.ppthttp://localhost/var/www/apps/conversion/tmp/scratch_1/16%20-%20TrueBeam%20short.pptxhttp://localhost/var/www/apps/conversion/tmp/scratch_1/17%20-%20VBT%20Products%20short.pptxhttp://localhost/var/www/apps/conversion/tmp/scratch_1/18%20-%20VPT%20Products%20short.pptxhttp://localhost/var/www/apps/conversion/tmp/scratch_1/12%20-%20UNIQUE%20short.pptxhttp://localhost/var/www/apps/conversion/tmp/scratch_1/13%20-%20Clinac%20short.pptxhttp://localhost/var/www/apps/conversion/tmp/scratch_1/11%20-%20Eclipse%20short.pptxhttp://localhost/var/www/apps/conversion/tmp/scratch_1/10%20-%20ARIA%20short.pptxhttp://localhost/var/www/apps/conversion/tmp/scratch_1/01%20-%20Cancer%20Tx%20short.pptx

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    3/48

    3 |  VARIAN ONCOLOGY SYSTEMS 

    3D-CRT

    MLC. MV imaging

    IMRT / RapidArc

    kV & MV IGRT

    Basic 2D RT

    no MLC, no imaging

    IMRT / RapidArc

    SRS/SRT

    kV & MV IGRT

    IMRT / RapidArc

    Neuro- & Radiosurgery

    Advanced IGRT

    UNIQUE

    Power

    UNIQUE

    Performance

    Clinac

    iX/DHX

    Trilogy

    Novalis Tx

    Complete

    Product Portfolio

    TrueBeam

    Investment

       C   l   i  n   i  c  a   l   C  a  p  a   b   i   l   i   t   i  e  s

    Tailored Solutions for all Clinical Requirements 

    Complete Product Portfolio

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    4/48

    4 |  VARIAN ONCOLOGY SYSTEMS 

    Clinical Challenges

    • Clinical Versatility 

    • Precision 

    • Decision 

    • Speed 

    New Treatment Capabilitiescombined with

    3D-CRT, IMRT & RapidArc

    SRS/SRT, IGRT & DART

    Mechanics

    Electronics (control)

    Imaging System

    Imaging Applications 

    Ergonomics of Software & HardwareIntegration & Safety Features

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    5/48

    5 |  VARIAN ONCOLOGY SYSTEMS 

    http://localhost/var/www/apps/conversion/tmp/scratch_1/2011-11-16%20TrueBeam,%20Kobe.pptx

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    6/48

    6 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ - Radically Different

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    7/48

    7 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ - Radically Different

    Field Size: 40*40 cm2 

    Center leafs (20 cm): 5 mm

    Outer leafs: 10 mm

    Field Size: 40*22 cm2 

    Center leafs (8 cm): 2.5 mm

    Outer leafs: 5 mm

    TrueBeam™  TrueBeam™ STx 

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    8/48

    8 |  VARIAN ONCOLOGY SYSTEMS 

    Radically Different

    TrueBeam™ 

    Innovative

    IntelligentIntuitive

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    9/48

    9 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ 

    Innovative

    New Architecture

    • The TrueBeam system has

    been designed from the

    ground up to optimize

    radiotherapy and radiosurgery

    • Real time control system

    provides a seamless integration

    of treatment, imaging and

    motion management

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    10/48

    10 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ 

    Innovative

    BeamGeneration

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    11/48

    11 |  VARIAN ONCOLOGY SYSTEMS 

    • Today in Clinics• Multi-Energy: 13 Carousel Positions available

    • 5 Flattened Photon Energies: 4, 6, 8, 10, 15, 18 & 20 MV

    • < 5 up to 600 MU/min

    • plus 2 High Intensity Mode Energies

    6X FFF, 10X FFF (Flattening Filter Free) 

    • 8 electron energies: many foils, 22e (max)

    • Future

    • low photon energy (2.5 MV) for MV imaging

    • 4 MeV electron

    TrueBeam™ 

    New Beam Generation System

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    12/48

    12 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ 

    High Intensity - Flattening Filter Free (FFF) Mode

    Higher dose rates, lower scatter

    and out of field leakage are

    possible by removing the

    flattening filter

    Gains for IMRT, RapidArc

    or small field SRS

     Available in clinical mode for

    6 MV 1400 MU/min

    10 MV 2400 MU/min

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    13/48

    13 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ 

    Red Journal - paper from

    University Zurich in Press

    FFF on TrueBeam

    High Intensity - FFF Mode - Literature

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    14/48

    14 |  VARIAN ONCOLOGY SYSTEMS 

    Non-flatness increases with energy

    Up to 3x3 cm2, difference in the profile for

    flattened and FFF is neglectable

    X6 X10

    X10FFFX6FFF

    TrueBeam™ data courtesy Hrbacek & Lang, University Hospital Zürich 

    TrueBeam™ 

    High Intensity - FFF Mode - Profiles

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    15/48

    15 |  VARIAN ONCOLOGY SYSTEMS 

    Leading the Way in Cancer Therapy

    • Prostate

    • Liver

    • Lung

    • Breast

    • SRS

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    16/48

    16 |  VARIAN ONCOLOGY SYSTEMS 

    FFF - Hypo-Fractionation (Hypo-fx) 

    • Hypo-fx is not a matter of technology but clinical

    feasibility & decision

    • Hypo-fx is not suitable for all indications

     Studies focused on lung, liver, brain & prostate cancers

    • Safety, precision and time are crucial for hypo-fx• TrueBeam delivers hypo-fx in the shortest possible time

    • Hypo-fx treatments can be performed on all Varian linacs

    t

    Standard-fx  – e.g. 40 x 2Gy = 80 Gy

    Hypo-fx  – e.g. 4 x 9.5 Gy = 38 Gy

    t

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    17/48

    17 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam - Clinical Benefit of High Intensity Mode

    Brain SRS

    Data courtesy

    Neolife Cancer Center

    Istanbul, Turkey

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    18/48

    18 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam - Clinical Benefit of High Intensity Mode

    Prostate SABR (Stereotactic Ablative Radiotherapy)

    Data courtesy

    Humanitas Institute

    Rozzano-Milano, Italy

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    19/48

    19 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam - Clinical Benefit of High Intensity Mode

    Lung SABR (Stereotactic Ablative Radiotherapy)

    Data courtesy

    VU University Medical Center

     Amsterdam, Netherlands

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    20/48

    20 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam - Clinical Benefit of High Intensity Mode

    Liver Mets SABR (Stereotactic Ablative Radiotherapy)

    Data courtesy

    Humanitas Institute

    Rozzano-Milano, Italy

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    21/48

    21 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ 

    Intelligent

    Superior

    ImageGuidance

    Simplified, Automated

    Imaging Modes

    • CBCT (Single Button)

    • kV/kV, MV/MV and MV/kV

    radiographic pairs

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    22/48

    22 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ 

    Intelligent

    Superior

    ImageGuidance

    Image Acquisition duringTreatment—kV and MV

    • Fluoroscopy— 

    with playback and review

    • MV Cine

    Respiration synchronized

    kV and MV Imaging

    • During setup

    • During treatment

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    23/48

    23 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ 

    Innovative

    Intrafraction

    MotionReview

    •  Acquire kV radiographs during

    treatment

    • Synchronized with respiration• Monitor tumor position

    throughout treatment

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    24/48

    24 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ Imaging 

    kV Fluoroscopy during RapidArc Treatment

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    25/48

    25 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ Imaging

    Intrafraction Motion Review - Fiducial Markers

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    26/48

    26 |  VARIAN ONCOLOGY SYSTEMS 

    New

    StandardsIn Accuracy

    TrueBeam™ 

    Intelligent

    • Mechanical and Imaging

    Isocenter Accuracy < 0.75 mm

    • Gantry rotational:

    < 0.3 degrees

    • Collimator rotational:

    < 0.5 degrees

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    27/48

    27 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ 

    Intuitive

    Simple,

     AutomatedOperation

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    28/48

    28 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ 

    Treatment Console

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    29/48

    29 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ 

    Intuitive

    • One button image acquisitionand full automation of beam

    delivery make treatments 50%

    faster*

    • Changing imaging procedures

    and protocols is simple and fast

    • Position and treat in less time

    than RapidArc benchmark50

    Faster

    %

    * Comparisons, Data on file, Trilogy system,

    Varian Medical Systems, 2010

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    30/48

    30 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam - Worldwide Clinical Operation

    ClinicalUse

    >270 installations

    >550 orders

    Registrations / Clearances: US FDA, CE Mark/ MDD, Russia Gost, Saudi Arabia SFDA, China SFDA, Japan Shonin,

     Australia & New Zealand, Thailand, Korea, India, … 

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    31/48

    31 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ 

    Work-in-progress

    ExoticTrajectories

    * Work-in-progress. Not available for sale.

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    32/48

    32 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ 

    Exotic Trajectories

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    33/48

    33 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ 

    Exotic Trajectories

    Red Journal - paper from

    MSKCC New York in Press

    Dynamic trajectory-basedalgorithm integrates

    optimized couch and

    collimator trajectories into

    RapidArc/VMAT

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    34/48

    34 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ 

    Exotic Trajectories

    Red Journal - paper from

    MSKCC New York in Press

    Dynamic trajectory-based

    algorithm integratesoptimized couch and

    collimator trajectories into

    RapidArc/VMAT

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    35/48

    35 |  VARIAN ONCOLOGY SYSTEMS 

    CalypsoGPS for the Body®

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    36/48

    36 |  VARIAN ONCOLOGY SYSTEMS 

    Calypso System Overview

    • Real-time motion management for radiation therapytreatments

    •  Accurate, precise, real-time tracking of treatment targets

    with electromagnetic technology

    • Designed for body-wide use

    • Prostate transponder FDA/CE cleared

    • Surface transponder cleared for body-wide use

    • Lung indication is a current work-in-progress

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    37/48

    37 |  VARIAN ONCOLOGY SYSTEMS 

    Beacon® Transponder

     Actual size: ~8.5 mm

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    38/48

    38 |  VARIAN ONCOLOGY SYSTEMS 

    Calypso Platform Overview

    4D Electromagnetic Array

    Implanted Beacon ®

    ElectromagneticTransponders

    4D Console

    4D Tracking Station

    Optical System with

    3 Infrared Cameras

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    39/48

    39 |  VARIAN ONCOLOGY SYSTEMS 

    Works in Progress

    Calypso 

    Tumor Tracking Technology

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    40/48

    40 |  VARIAN ONCOLOGY SYSTEMS 

     Augmenix – SpaceOAR™ Hydrogel 

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    41/48

    41 |  VARIAN ONCOLOGY SYSTEMS 

    RapidArc

    Radiosurgery 

    TrueBeam™ 

    6 Degrees of Freedom (6DoF) Couch

    Works in Progress – Not for Sale

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    42/48

    42 |  VARIAN ONCOLOGY SYSTEMS 

    RapidArc

    Radiosurgery 

    TrueBeam™ 

    6 Degrees of Freedom (6DoF) Couch

    Works in Progress – Not for Sale

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    43/48

    43 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ 

    Clinical relevance

    • Vertebrae

    • High dose gradients around the

    spinal cord• Pitch is important when the

    tumor spreads over more than

    one vertebra

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    44/48

    44 |  VARIAN ONCOLOGY SYSTEMS 

    Image: VUMC Amsterdam

    TrueBeam™ 

    Clinical relevance

    • Intracranial tumors

    • Sparing optical structures

    (optical chiasm, optical nerve)

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    45/48

    45 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ 

    Clinical relevance

    • Lungtop

    • Very sensitive to arm position

    • Sparing myelum and plexus

    T B ™

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    46/48

    46 |  VARIAN ONCOLOGY SYSTEMS 

    TrueBeam™ 

    Summary

    Radically

    DifferentFuture

    • Designed to optimize

    radiotherapy and radiosurgery

    • Integrates and choreographs

    powerful imaging and treatment

    systems

    • Unparalleled accuracy

    • Unlocks new treatment options

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    47/48

    47 |  VARIAN ONCOLOGY SYSTEMS 

    Our Vision

    Make Cancer a manageable, chronic disease

    that can be treated by our products better and

    more cost-effectively

    Make advanced therapy affordable for

    many around the world, not few

  • 8/16/2019 15_ Staehelin, Varian Technology Update - TrueBeam

    48/48

    48 |  VARIAN ONCOLOGY SYSTEMS