1020/SKPS/CAS/20 Case Study Sap & Kaps Petroleum Services l.l.c Page 1/2 [email protected] 18” Propane Liquid export Pipeline with severe external pitting and pin holes

1020-SKPS-CAS-20-Case Study-18” Propane Liquid export

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

1020/SKPS/CAS/20

Case Study

Sap & Kaps Petroleum Services l.l.c

Page 1/[email protected]

18” Propane Liquid exportPipeline with severe

external pitting and pin holes

1

Design Criteria 4

Comprehensive repair solution using Clock Spring Contour composite wrapping was applied in 8 layers extending 16.00 meters. The line was operational in less then 2 days.

3 Clock Spring ® contour composite Wrapping

Pipe surface preparation was completed to SA 2½ . The pin holes were arrested using a special 2 layer system elastomer plug, the sealing plug was secured by fast curing high strength putty.

2 Surface Preparation

Defect area18” Propane Pipeline had several pin holes due to severe external corrosion defects. The holes size varied from 3 mm up to 8 mm. The pipe had been put out of service, SKPS team immediately mobilized to location and provided the remedial action.

Actual Wall Thickness

Remaining Thickness

Defect Type

Size

Material

Defect Analysis

Orientation of Leak

Lifetime

: 12 bar

: 20 degC

: External corrosion

: 18”

: A671 Gr.CC60 CL.22

: Through wall-Pin holes

: 6 o’clock

: 2Years

1020/SKPS/CAS/20 [email protected] Page 2/2

18” Propane Liquid export Pipeline with severe external pitting and pin holes