58
1

1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

Embed Size (px)

Citation preview

Page 1: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

1

Page 2: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

2

Page 3: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

3

Page 4: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

4

Page 5: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

5

Page 6: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

6

Page 7: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

7

Implant Direct: 1H08 to 1H09 Increase 54%

Full Year-9% Dental

Fourth Quarter-19% Dental

Implant InnovationsYear End May 31, 2009

Do not break out dollars for Dental

1H08412.8M CHF

1H09384.1M CHF

Straumann

Sales Dropped 6.9%

1H08$119.1

1H09$101.1

Zimmer Dental

Sales Dropped 16%

1H08323.8M Euros

1H09300.4M Euros

Nobel Biocare

Sales Dropped 11.3%

Page 8: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

8

Barron’s Magazine Referred to Dr. Niznick as the Godfather of American Implant Dentistry

Page 9: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

9

1986 Dr. Niznick Introduced Screw-Vent with Internal ConnectionConsidered by many as the Cornerstone of Modern Implants

Page 10: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

10

Evolution of the Screw-Vent 1985-2000Origin of Zimmer Dental – #4 in Industry

Page 11: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

11

Dr. Niznick retained ownership of factory and when lease expired in 2004, he reoccupied building and built State of Art Facility

Page 12: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

12

Implant Direct’s Product Line and Marketing Strategy is “Transforming the Implant Industry”

Spectra-System: Launched October 2007:

1. 5 Application Specific Implants

2. 6th Implant – GoDirect – Launch Sept. 2009

3. All-in-1 packaging @ $150

4. Same design body: Tapered with Micro-threads (Patent Pending)

5. Same surgical protocol – compatible with Zimmer Dental’s Tapered Screw-Vent, Developed by Dr. Niznick in 1999

Page 13: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

13

Spectra-System – 6 Application Specific Implants1-Body & Surgical Protocol/6-Platforms/All-in-1 Packaging

Page 14: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

14

Page 15: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

15

Screw-Plant’s Patented Healing Collar/Extender and Patent Pending Fixture-mount/Transfer/Abutment

Page 16: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

16

Dr. John Cavallaro Reports Results 2007-2009 with ScrewPlant

165 placed 1 failed @ S2; 1 bone to 1st body threadSurvival to date 99.4%; Failed .6% [failed implant successfully re-done]ADVANTAGES: Trouble-free connection, Many Prosthetic Options, Value

Page 17: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

17

Legacy Implant Launched Oct. 2007 when Niznick Patent #4,960,381, sold to Zimmer Dental in 2001, expired

Page 18: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

18

Zimmer Dental’s Screw-Vent Accounts for 85% of its Implant Sales

Page 19: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

19

Page 20: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

20

Niznick Launched Legacy3 @175 in July 2009 – Includes Abutment.

Implant Direct Dropped Price of Legacy1 from $150 to $125

Page 21: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

21

Page 22: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

22

Implant Direct’s Legacy3, 2-piece Implant in 3.2mmD @ $175

Zimmer Dental’s only Narrow Implant is 1-Piece @ $500 Legacy3 3.2mmD Implant with Fixture-mount/Transfer/Abutme

nt

Page 23: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

23

Legacy3 4.2mmD with Platform Switching Conical Connectionand All-in-1 Packaging for ease of ordering and added value

Page 24: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

24

Legacy2, with Titanium Fixture-mount/Transfer to Launch Nov. 09 Straight for Top 1/3rd with more aggressive self-tapping threads. Targeted at MIS and NobelActive

Page 25: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

25

Nobel Biocare – Market Leader with +30% Most Popular Implant is NobelReplace Tri-lobe – 1,000,000 Sold Each Year.

Implant Direct Received Patent on Tri-lobe Connection that Circumvents Nobel’s Patent and Provides Compatible Interface

Page 26: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

26

Niznick Patent on Double Tri-lobes, Circumvents Nobel’s Patent Fixture-mounts engage both for double the anti-rotational stability

Page 27: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

27

Double Tri-lobe Pat. 7,108,510

1. Circumvents Nobel Patent.

2. Niznick Patent Blocks only way around Nobel Patent

3. Abutments –Cross-Compatible with Nobel

4. Increased stability with Fixture-mount Abutment

Micro-thread Patent Pending

1. Increases stability,

2. Reduced bone loss (Astra)

3. Gets around Nobel Method Patent of insertion with Step-drill (Bluesky infringing)

Page 28: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

28

Page 29: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

29

Page 30: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

30

Page 31: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

31

NobelActive … “For Experienced users”

Implant Direct’s ReActive… “Simply Smarter”

Cutting Groove in Reverse to help remove implant, not insert it

Sharp Apical End Can Tear Sinus Membrane

Page 32: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

32

Nobel Biocare Acquired Israeli Company for $95M in 2008 and Launched NobelActive with Niznick Type Lead-in Bevel/Internal Hex ConnectionNiznick Development of ReActive from Design to Launch in 7 MonthUnlike NobelActive, ReActive Retained Popular Tri-lobe Connection

Legacy3 Provides Same Body as ReActive (Progressively deeper threads)Unlike NobelActive, Legacy3 used Popular Screw-Vent Connection

Page 33: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

33

NobelActive Design Flaws include tapers at top leaving gap between bone, reverse cutting groove, sharp apex, poor qualityLegacy3 with Design Advantages including Micro-threads, the

original Internal Hex/Bevel Connection & Superior Manufacturing

Page 34: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

34

NobelActive Conical Connection has long 78 degree bevel with short hexImplant Direct’s Internal Connection has short 44 degree bevel with long hex

Bevel is 2X+ Hex

Hex is 2+ Bevel 44 Degree Bevel

Page 35: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

35

NobelActive Connection Requires X-ray to Confirm Seating of Transfers and Abutments – Could Result in Prosthesis not fitting

Page 36: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

36

NobelActive inaccuracy in seating Transfers is shown in published article in July 2009 Journal – will lead to inaccuracy in fit of Crown

Page 37: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

37

NobelActive inaccuracy in seating Transfers is shown in published article in July 2009 Journal – will lead to inaccuracy in fit of Crown

Article in Dental Tribune July 2009 Page 2B by Dr. Terry Myers shows a transfer in a NobelActive that is not

fully seated – Gap on margins of both sides

Nobel Biocare Instructions. Take X-ray and measure to see if Transfers and

Abutments are fully seated

NobelActive Restorative Manual with X-ray Examples of Abutments that are and are not

properly seated

Page 38: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

38

NobelActive Internal Hex/Bevel Connection deviates from Niznick’s 1986 Screw-Vent Design, resulting in loss of feel of

positive seat

44 Degree Bevel

Hex 0.32mm Below Top

Sharp Corners

78 Degree Bevel

Hex 0.88mm Below Top

Round Corners

Alpha Bio Connection Legacy Connection

Page 39: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

39

$175

Incl.

Incl.

Incl.

Incl.

Savings with ID $754-$175 = $579

ID Online Ordering = 19 Fewer Clicks

Implant Direct’s Legacy3 Implant With Internal Hex/Bevel Connection VS

Nobel Biocare’s NobelActive Implant with Internal Hex/Bevel Connection

Page 40: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

40

Featured in Dental Lab Journal

Implant Direct offers full line of Abutments

compatible with Nobel, Zimmer, Straumann,

BioHorizons and MIS Implants

Page 41: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

41

Straumann is Second Largest Company in Implant Industry, Selling Tissue-level and recently launched Bone-level Implants

Page 42: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

42

Implant Direct Launches SwissPlant June 2009Surgically and Prosthetically Compatible with Straumann’s

Tissue-level Implant but can also be used Bone-level

Internal Octagon

Connection with Square

Broached on Flats

for Insertion

Pat. Pend.

Page 43: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

43

Implant Direct Launched SwissPlant Implant System in June, 2009 One Implant designed for both Tissue- and Bone-Level Placement

Page 44: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

44

Page 45: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

45

SwissPlant System with Multi-Positional 2mm Neck SwissPlant System With Multi-Positional Platform Height

45

Page 46: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

46

SwissPlant with Dual Blast Surface allows bone-level placementSwissPlant:Surgically & Prosthetically compatible with Straumann

Page 47: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

47

SwissPlant Introductory Offer – 3 Free Implants

Page 48: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

48

SwissPlant Abutment Options for Straumann Implants

Page 49: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

49

BioMet’s 3i Implant Sales Dropped 19% 4Q08 to 4Q09 Fiscal Year

Implant Direct has reverse engineered 3i implant and figured out

design-around for their patent

Plan Production in 2010

Page 50: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

50

Implant Direct has Designed External Hex Implant with Tapered Hex for 2010 – Niznick’s Tapered Ext. Hex Patent Expires

Page 51: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

51

Astra’s Unique Selling Proposition - Claim that Micro-threads Reduce Bone Loss – Niznick has Pat. Pending on Improved Micro-threads

Double-lead Body Threads for faster insertion

Quadruple-lead Miro-threads for increased bone engagement

Page 52: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

52

Common Feature of all Implant Direct Implants Patent Pending Quadruple-lead Mini-Threads with Double-lead Body Threads

Page 53: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

53

Page 54: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

54

Sybron PRO 1-Stage Implant with Internal Hex is Not Compatible with Straumann – Can be replaced with SwissPlant

Pitt-Easy Implant is 20 Year old Design with Internal Hex and Butt Joint Platform – Can be Replaced by Legacy 1,2, & 3.

Page 55: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

55

Implant Direct will Launch Implant Guided Surgery System, owned by Niznick Enterprises after 5 years and $7M in Development

Page 56: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

56

Implant Direct invested $450,000 in last 3 months to acquire Chiron 5 Axis CNC Milling Machine and DelCam Software

Page 57: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

57

Drilling

Page 58: 1. 2 3 4 5 6 7 Implant Direct: 1H08 to 1H09 Increase 54% Full Year -9% Dental Fourth Quarter -19% Dental Implant Innovations Year End May 31, 2009

58

Template with Guide Sleeves Fabricated from Treatment PlanDeveloped with ILS Software - Drill Guides fit into Sleeve