62
Wiring and Programming Guide 045-101-12 rev A Window Systems Quiet Electronic Drives

045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

  • Upload
    lyquynh

  • View
    236

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Wiring and ProgrammingGuide

045-101-12rev A

Window SystemsQuiet Electronic Drives

Page 2: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

Sivoia QEDTM Quiet Electronic Drive Window System ii

Table of ContentsSYSTEM WIRINGElectronic Drive Unit (EDU) Wiring . . . . . . . . . 1.2Single EDU Wiring . . . . . . . . . . . . . . . . . . . . . 1.3Wire and Power Supply Specification . . . . . . . 1.4Wiring Using Individual Power Supplies . . . . . 1.5Multiple EDU Wiring . . . . . . . . . . . . . . . . . . . 1.7SV-CCI-8 Wiring Detail . . . . . . . . . . . . . . . . . 1.8Infrared Receivers . . . . . . . . . . . . . . . . . . . . 1.9

PROGRAMMING OVERVIEWSystem Overview . . . . . . . . . . . . . . . . . . . . . 2.2

ADDRESSINGAddressing from Controls . . . . . . . . . . . . . . . 2.6Addressing from the EDU . . . . . . . . . . . . . . . 2.32

SETTING LIMITSSetting Limits from the EDU . . . . . . . . . . . . . 2.3Setting Limits from Controls . . . . . . . . . . . . . 2.10

ASSIGNING EDUsAssigning EDUs to Controls . . . . . . . . . . . . . . 2.15Assigning EDUs to Multi-group IR Transmitters 2.20

PRESETSStoring Presets . . . . . . . . . . . . . . . . . . . . . . . 2.28Locking Presets . . . . . . . . . . . . . . . . . . . . . . 2.30

LEVEL ADJUSTAdjusting Individual Levels . . . . . . . . . . . . . . 2.24

ADVANCED PROGRAMMINGAdding Components . . . . . . . . . . . . . . . . . . . 2.31Restoring Keypads and CCIs to Default Settings . . . . . . . . . . . . . . . . . . . . . . 2.35Restoring Entire System to Default Settings . . 2.38Restoring EDU to Default Settings . . . . . . . . . 2.43Multiple Groups with the CCI . . . . . . . . . . . . . 2.44

TROUBLESHOOTINGTroubleshooting Chart . . . . . . . . . . . . . . . . . . 3.2

For information on placement and mounting of theEDU brackets, refer to the installation guideincluded with each roller blind and curtain.

Page 3: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

Sivoia QEDTM Quiet Electronic Drive Window System 1.1

Sivoia QEDTM

System Wiring

Page 4: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

WIR

ING

Sivoia QEDTM Quiet Electronic Drive Window System 1.2

EDU wiringWiringF U N C T I O N :

Sivoia QED Electronic Drive Units (EDUs) are designed tofunction in four ways:

• A single EDU can be controlled individually by a keypad,IR transmitter, or contact closure interface (CCI).

• Multiple EDUs can be linked through programming tooperate in groups and subgroups, regardless of locationon the link. EDU groupings can be changed at any timesimply by reprogramming the system.

• EDUs can be operated by larger entire-room or whole-house lighting control systems such as Lutron’s GRAFIKEye®, or HomeWorks® systems.

• EDUs can also be operated by control systems made byother manufacturers.

G E N E R A L FA C T S :

• Microprocessors are contained in the EDU, keypad, CCIand IR transmitter, allowing high-level programmingfrom any source.

• The keypads are low-voltage and receive their powerfrom the EDUs. EDUs receive their power via a 24 V~power supply. One power supply is required per EDU.

• Keypads are wired directly to a communication link,which connects to one or more EDUs, CCIs and keypads.See Programming Section for more information on EDUgrouping by function.

• A contact closure input is available, when required, toconnect with an outside system. The contact closureinput wires to the EDU communication link.

P L A N N I N G Y O U R I N S TA L L AT I O N :

Taking time to plan out the wiring on paper will helpenormously, especially in multiple EDU installations.

Some common questions to answer up front include:

• What are the power requirements?

Sivoia QED system operates on 24 V~ and requiresthe use of a low-voltage power supply.

The specification of the power supply is provided onpage 1.4.

Each EDU must be powered from its own powersupply.

A certified electrician should install all of the linevoltage power.

The keypads are all low-voltage and can be installedby a low-voltage system installer.

• What size of cable is needed?

Please refer to the charts on page 1.4.

• Can I expand the system later on?

A communication link can connect up to 96 totaldevices (EDUs, keypads or CCIs).

An external keypad power supply is required whenthe total number of keypads and CCIs in aninstallation exceeds the number of Sivoia QED EDUs.

Page 5: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

single EDU wiring

Technical Support :+44-(0)20-7702-0657

WIR

ING

Sivoia QEDTM Quiet Electronic Drive Window System 1.3

Wiring

Lutron Sivoia QEDseeTouch keypadBACK

4

3

2

1

Com

mon

12V

MUX

MUX

AC AC EGND

Basic Installation (Plug-In Power Supply shown)

AC GRD AC

.75.75 .75".75"

male EDUconnector

female terminalblock

p/n 441487

To other EDUs,keypads, CCIs

AC Eart

h Gr

ound

AC

24 V~ Power Supply

24 V~ Power Supply

LUTRON

Page 6: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

WIR

ING

Sivoia QEDTM Quiet Electronic Drive Window System 1.4

wire and power supply specificationsWiringWIRE TYPES

A Communications Link4 Conductor 1.0 mm2 (#18AWG) (twisted andshielded)Maximum comm Link - 1220 m (4000 ft)GRX-CBL-346S-500 may be used for the Com-munication Link as long as the 1.0 mm2 (18AWG) conductors are used for the +12V andCommon

B Power Supply3 Conductor 1.5–0.75 mm2 (#16–20AWG)

POWER SUPPLY

MAXIMUM WIRE LENGTH

Keypad to Power Panel1 keypad - 305 m (1000 ft)2 keypads - 150 m (500 ft)3 keypads - 90 m (300 ft)4 keypads - 60 m (200 ft)

EDU to Panel1.5 mm2 (#16AWG) - 60 m (200 ft)1.0 mm2 (#18AWG) - 45 m (150 ft)0.75 mm2 (#20AWG) - 30 m (100 ft)

Note: Power supply wires should NOT be in the sameshielding as communication wires.

1) GENERAL REQUIREMENTS:a) MUST have independent 3rd party certification to

Safety Isolating Transformer Standard EN61558-2-6.b) Manufacturer MUST be able to provide documentation

supporting the 3rd party certification.c) The CE mark alone is NOT acceptable.d) One power supply is required per motor.

(failure to do so may cause the system to functionimproperly)

2) ELECTRICAL RATINGS:a) Input Voltage: As Appropriate, 50/60 Hzb) Output voltage:

• Nominal: 24 Volts AC RMS • Minimum: 22.5 Volts AC RMS at 3 Amps (Maximum

Load on Secondary)• Maximum: 30 Volts AC RMS with No Load on

Secondary.• 67 VA minimum at 90% Line Voltage• 100 VA maximum

3) OUTPUT PROTECTION:a) Fused Secondaryb) Resetable or Non-Resetable

• 3 Amps Minimum• 5 Amps Maximum

4) GENERAL INFORMATION:

a) Depending on the weight and thickness of the fabric:

• A 50 VA rated transformer will drive approximately5 m2 (55 ft2) of fabric.

• A 100 VA rated transformer will drive approximately10 m2 (110 ft2) of fabric.

Page 7: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

WIR

ING

Sivoia QEDTM Quiet Electronic Drive Window System 1.5

wiring using individual power supplies

CCI

CCI

Sivoia QEDKeypad

Sivoia QEDKeypad

Sivoia QED EDU

IR Receiver

Sivoia QED EDU

IR Receiver

Sivoia QED EDU

IR Receiver

Sivoia QED EDU

IR Receiver

24 V~Pow

erSupply

Sivoia QED EDU

IR Receiver

Sivoia QED EDU

IR Receiver

To Lighting System(Lutron GRAFIK Eye)

2 conductorsnot used

Sivoia QED Comm

unications Link (4 conductor,1.0 m

m2(18 AW

G) twisted

shielded) (GRX-CBL-346S-500)Pow

er Cable (3 conductor)

AB

B

A

Wiring24 V~Pow

erSupply

24 V~Pow

erSupply

24 V~Pow

erSupply

24 V~Pow

erSupply

Page 8: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

WIR

ING

Sivoia QEDTM Quiet Electronic Drive Window System 1.6

wiring using individual power suppliesWiring

Open

Close

LUTRON

AC GRD AC

AC GRD ACAC GRD AC

A

B

For larger systems with more than four keypads, distribute keypads evenly on link - maximum one keypadbetween EDUs.

Up to four keypads and 120 m (400 ft) total length of communications wire, no requirement for evendistribution.

Open

Close

LUTRON

Open

Close

LUTRON

AC GRD ACAC GRD AC

AC GRD AC

WIRE TYPES

A Communications Link4 Conductor 1.0 mm2 (#18AWG) (twisted andshielded)

B Power Supply3 Conductor 1.5–0.75 mm2 (#16–20AWG)

MAXIMUM WIRE LENGTH

EDU to EDU - 150 m (500 ft)Maximum total communications link - 1220 m (4000 ft)

Power supply to EDU1.5 mm2 (#16AWG) - 60 m (200 ft)1.0 mm2 (#18AWG) - 45 m (150 ft)0.75 mm2 (#20AWG) - 30 m (100 ft)

• One CCI counts as one keypad• Number of keypads and CCIs not to exceed number of

EDUs without the need additional power supplies.

Open

Close

LUTRON

B

24 V~PowerSupply

24 V~PowerSupply

24 V~PowerSupply

24 V~PowerSupply

24 V~PowerSupply

24 V~PowerSupply

Page 9: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

WIR

ING

Sivoia QEDTM Quiet Electronic Drive Window System 1.7

multiple EDU wiringWiring

Lutron Sivoia QEDseeTouch keypad

BACK

To otherEDUs,

keypads,or CCIs

To otherEDUs,

keypads,or CCIs

• Every keypad, CCI, and EDU is connected by the SivoiaQEDTM Communication Link.

• Wire each EDU to a separate power supply.

• Each EDU must be EARTH grounded.

• Each power supply, of any type, can power ONLY ONEEDU, regardless of blind size.

A Communications Link 4 Conductors

B Power Wires 3 Conductors

Please refer to Tables on page 1.4 for details on thesewires.

4

3

2

1

Com

mon

12V

MUX

MUX

AC AC EGND

Com

mon

12V

MUX

MUX

AC AC EGND

female EDU connectorfemale EDU connector

AB

AC Eart

h Gr

ound

AC

24VAC Power Supply

AC Eart

h Gr

ound

AC

24VAC Power Supply

Page 10: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

WIR

ING

Sivoia QEDTM Quiet Electronic Drive Window System 1.8

SV-CCI-8 wiring detailWiringInput channel will accept dry contact closures and opencollector outputs (Vce ≤ 0.3 V).

Do not apply voltage to any input channel.

• By default all contact closures on a CCI operate thesame group of EDUs.

• By default the CCI has Open, Close, Preset 1, Preset 2,Preset 3, Stop, Raise, and Lower inputs.

• LEDs provide feedback on contact closure state.

Input 1 - Defaults to Open

Input 2 - Defaults to Preset 1

Input 3 - Defaults to Preset 2

Input 4 - Defaults to Preset 3

Input 5 - Defaults to Close

Input 6 - Defaults to Stop

Input 7 - Defaults to Raise

Input 8 - Defaults to Lower

External Switch Closures (supplied by customer)

Sivoia QED Communication Link:To other keypads, CCIs and EDUs.

4 (MUX)

3 (MUX)

2 (12 V)

1 (Common)

A

• Terminal blocks accommodate 1.5–0.5 mm2

(14–22 AWG) wire.

• The CCI can be configured to control two groups withOpen, Preset, Close, and Stop functionality, or withOpen, Close, Raise, and Lower functionality.

• The CCI can be configured to control four groups withOpen and Close functionality.

Page 11: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

WIR

ING

Sivoia QEDTM Quiet Electronic Drive Window System 1.9

infrared receiversWiringRemote IR EyeLutron offers a remote infrared eye for Sivoia QED. It is asmall dome connected to the EDU by a thin 558 mm(22 in) cable.

The remote infrared eye plugs into a dedicated IRconnector on the EDU. Extensions of 3 m (10 ft) lengthsare available if the layout requires the IR eye to be locatedfurther from the EDU. The IR eye may be located up to15 m (50 ft) away from the EDU. Unobtrusive mountingclips and adhesive tape are also provided.

.75.75 .75".75"

Remote IR Eye(not shown to scale,has a diameter of25 mm (1.0 in)

SV-IRInfrared remote eye, available

in white and royal plum

SV-IR-EXT-10SV-IR connects tooptional extensioncable (SV-IR-EXT-10)or directly to EDU

3 m(10 ft)

Page 12: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

WIR

ING

Sivoia QEDTM Quiet Electronic Drive Window System 1.10

notesWiring

Page 13: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

Sivoia QEDTM Quiet Electronic Drive Window System 2.1

Sivoia QEDTM

System Programming

Page 14: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

PR

OG

RA

MM

ING

OV

ERV

IEW

Sivoia QEDTM Quiet Electronic Drive Window System 2.2

system overviewBasic ProgrammingComponents

The components of a Sivoia QED system include:Electronic Drive Units (EDUs) operated by keypads,infrared (IR) transmitters, or contact closure inputs (CCIs).EDUs, keypads, and CCIs are connected directly to theSivoia QED Communications Link.

Each keypad, IR transmitter, and CCI can be setup tooperate all of the EDUs in the system, a single EDU, or anycombination of EDUs in a user-defined group.

Keypads are wall mounted and provide open, close,preset, and momentary raise/ lower functions.

IR transmitters require an IR receiver that can be integralto a keypad or CCI, or connected to an EDU. IRtransmitters provide open, close, preset, and momentaryraise/ lower functions.

CCIs are mounted in a panel, and provide input to theSivoia QED system from another automation system. CCIsprovide open, close, preset, momentary raise/ lower, andstop functions.

Factory Defaults

As shipped from the factory, the Sivoia QED system willprovide basic Open, Close, and momentary Raise andLower functionality. This allows wiring to be verified beforeprogramming. As shipped from the factory, each keypad,IR transmitter, and CCI will operate every EDU in thesystem. Open and Close Limits will need to be set oncethe EDUs are installed. The system will need to beprogrammed in order to access all Sivoia QED features,including storing presets, assigning EDUs to keypads, IRtransmitters and CCIs.

Planning

Before starting programming, determine which EDUsshould be operated by each keypad, IR receiver, and CCI inthe Sivoia QED system.

Programming

Program the system after all components have beenwired, installed, and powered. Programming the systemallows presets to be stored and recalled; limits to beadjusted from keypads, CCIs, and IR transmitters; andgroups of EDUs to be assigned to keypads, CCIs, and IRreceivers.

Programming the Sivoia QED system consists ofaddressing all of the components, setting an open andclose limit for each EDU, and assigning EDUs to eachkeypad, IR receiver, and CCI.

Addressing – Addressing the Sivoia QED components isrequired for the system to function properly. Addressingcan be accomplished from an EDU, a keypad, an IRtransmitter, or a CCI. After addressing a new system,keypads, CCIs, and IR transmitters will not operateany EDU. Finish system programming by setting EDUlimits and assigning EDUs to keypads, CCIs, and IRreceivers.

Setting Open and Close Limits – The open and close limitsmust be set for every EDU. The open and close limitsdetermine how far an EDU will travel. If desired, limits canbe set using the buttons on the EDU before the system isaddressed.

Assigning EDUs – Assignment is required and determineswhich EDU will be operated by each keypad, IRtransmitter, and CCI. After addressing, no EDUs areassigned to keypads, CCIs or IR receivers. Assigning EDUsto keypads, CCIs, or IR receivers allows operation of anindividual, a user-defined group of EDUs, or all EDUs asdesired.

Page 15: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

SETTIN

GLIM

ITS

Sivoia QEDTM Quiet Electronic Drive Window System 2.3

setting limits from the EDUBasic ProgrammingSetting Limits Overview

The Open and Close Limits can be set from the EDU, aCCI, keypad or IR transmitter with at least: an Open, Close,Raise and Lower buttons.

The advantage of setting limits remotely from a keypad, IRtransmitter, or CCI, is that these components are generallyeasier to access. Setting limits at the EDU may be simpler,and can be done before addressing the system, dependingupon the installation.

The Open and Close Limits determine how far an EDU willtravel. When the open button is pressed on a keypad, IRtransmitter, or CCI, the EDU will move to the Open Limit.When the close button is pressed on a keypad, IRtransmitter, or CCI, the EDU will move to the Close Limit.The EDU will not move higher than the Open Limit orlower than the Close Limit.

Note: Setting the Open Limit lower than the Close Limitwill cause the blind to move down when raise is pressedand up when lower is pressed.

As an alternative to setting limits from the EDU, limits maybe set from a keypad, IR transmitter, or CCI after thesystem has been addressed. To set the limits from akeypad, IR transmitter, or CCI, address the system as onpage 2.6 and then set the limits as described on page2.10.

Setting the Open Limit from the EDU

STEP 1

Tap the “Open Limit Button” ( ). The LED on a rollerblind EDU will turn on (steady LED), indicating the EDU isin “Set Open Limit Mode.” The display on a curtain trackEDU will show ( ).

Tap the Open LimitButton

Steady LED

Tubular EDU

External EDU

Page 16: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

SETTIN

GLIM

ITS

Sivoia QEDTM Quiet Electronic Drive Window System 2.4

setting limits from the EDUBasic ProgrammingSTEP 2

Adjust the position of the EDU to the desired Open Limitusing the adjustment buttons ( ).

STEP 3

Press and hold the “Open Limit Button” ( ) for 5seconds. The LED on a roller blind EDU will flash for 2seconds then go dark, indicating the current position hasbeen stored as the Open Limit. The display on a curtaintrack EDU will flash ( ).

Press and hold the OpenLimit Button for 5 sec-onds

Flashing LED

Use the Adjustmentbuttons to move theEDU

Page 17: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

SETTIN

GLIM

ITS

Sivoia QEDTM Quiet Electronic Drive Window System 2.5

setting limits from the EDUBasic Programming

STEP 3

Press and hold the “Close Limit” button ( ) for 5seconds. The LED on a roller blind EDU will flash for 2seconds indicating the current position has been stored asthe Close Limit. The display on a curtain track EDU willshow ( ).

Setting the Close Limit from the EDU

STEP 1

Tap the “Close Limit Button” ( ). The LED on a rollerblind EDU will turn on (steady LED), indicating the EDU isin the “Set Close Limit Mode.” The display on a curtaintrack EDU will show ( ). Do not hold the “Close LimitButton” for more than 1 second.

STEP 2

Adjust the position of the EDU to the desired Close Limitusing the adjustment buttons ( ).

Tap the Close LimitButton

Steady LED

Press and hold theClose Limit buttonfor 5 seconds

Use the Adjustmentbuttons to movethe EDU

After setting limits, address the system and assign EDUsto keypads, CCIs, and IR receivers.

Addressing from controls page 2.6Addressing from an EDU page 2.32Assigning EDUs to controls page 2.15Assigning EDUs to multi-group IR transmitter page 2.20

Page 18: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AD

DR

ESS

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.6

addressing from controlsBasic ProgrammingAddressing Overview

Each keypad, EDU, and CCI in the system must have aunique address in order to store presets. Addressing thesystem gives each device a unique address number, whichallows individual components to communicate properly.

Each device can be given a unique address automatically,by placing a single keypad, EDU, IR transmitter, or CCI in“Addressing Mode.” The device in Addressing Mode willthen allocate a unique address to every keypad, EDU, andCCI in the system.

The Sivoia QED system is addressed using a singlekeypad, EDU, CCI, or IR transmitter. It is not necessary toenter address mode on more than 1 device in the system.For convenience, address the system from the componentthat is easiest to access.

The system should be addressed each time newcomponents are added. Addressing a previouslyprogrammed system will not erase any previousprogramming, addresses, limits, EDU assignments, orpresets.

After addressing a new system keypads, CCIs, and IRtransmitters will not operate any EDU.

Once the system has been addressed, EDUs need to beassigned to the appropriate keypads, CCIs and IRreceivers.

Notes:

• The system should be addressed after all componentshave been installed, wired to the communications link,and powered.

• To add previously addressed components to an existingsystem, or to connect a previously addressed systemto an existing system, return components to factorydefaults before wiring them to the existing system(refer to Advanced Programming).

• The CCI can be configured to accommodate multiplegroups of blinds (see page 2.44). Configurations otherthan the default have Open and Close inputs inlocations other than inputs 1 and 5.

STEP 1

For the CCI, begin by setting switch 6 to OFF. Skip thisstep for keypads and IR transmitters.

Turn Switch 6OFF

• Controls for integrating with other Lutron systems,including the SG-SVC/SO-SVC cannot address theSivoia QED system or set limits. These controls operateevery EDU.

Addressing only needs to be done from one device in thesystem. When a device is put into Addressing Mode, it willaddress all of the components in the system.

Page 19: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AD

DR

ESS

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.7

addressing from controlsBasic Programming

LUTRON

STEP 2

Press and hold the Open (Open) and Close (Close) buttonssimultaneously for 5 seconds. The LEDs next to the Openand Close buttons on the keypad or CCI will flash once persecond.

Flashing LEDs

Press and holdthe Open (Open)and Close (Close)buttons for 5seconds

Press and holdthe Open (Open)and Close(Close) buttonsfor 5 seconds

Press and holdthe Open (Open)and Close(Close) buttonsfor 5 seconds

IR Transmitter IR Transmitter

Open

Close

Open

Preset

Close

Tap the Open(Open) button

Flashing LED

Tap the Open(Open) button

Tap the Open(Open) but-ton

Open

Close

LUTRON

Open

Preset

Close

STEP 3

Tap the Open (Open) button to enter “Addressing Mode.”The LED next to the Close button will flash quickly (8times per second), the LED next to the Close (Close) buttonwill turn off. The system is now being addressed.

Page 20: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AD

DR

ESS

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.8

addressing from controlsBasic ProgrammingSTEP 4

Wait for addressing to be completed. This will takeapproximately one minute. While addressing is inprogress, each keypad and CCI will flash its Open (Open)LED quickly (8 times per second). Each EDU will flash itsLED quickly (8 times per second).

When addressing has successfully completed, Open(Open) and Close (Close) LEDs on every keypad and CCIwill flash slowly (once per second). The LED on the EDUwill flash slowly (once per second).

Correct wiring can be confirmed by checking that eachkeypad, CCI, and EDU is flashing its LED. If a device doesnot flash its LED, wait for addressing to complete, checkwiring, and re-address the system, entering addressingmode from the same device that was previously used toaddress the system.

Flashing LED

Flashing LEDs

LUTRON

Open

Preset

Close

LUTRON

STEP 5

Press and hold the Open and Close buttons simultaneouslyfor 5 seconds to exit “Addressing Mode.”

Press and holdthe Open (Open)and Close (Close)buttons for 5seconds

Press and holdthe Open (Open)and Close(Close) buttonsfor 5 seconds

Press and holdthe Open (Open)and Close(Close) buttonsfor 5 seconds

Open

Close

Open

Preset

Close

Page 21: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AD

DR

ESS

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.9

addressing from controlsBasic ProgrammingSTEP 6

For the CCI, return switch 6 to ON. Skip this step forkeypads and IR transmitters.

Turn Switch 6OFF

After the system has been addressed for the first time, noEDUs will be assigned to, or controlled by keypads, IRtransmitters, or CCIs. The keypads will have all LEDs litbrightly, indicating that no EDUs are assigned.

Setting limits from an EDU page 2.3Setting limits from controls page 2.10Assigning EDUs to controls page 2.15Assigning EDUs to multi-group IR transmitter page 2.20

Page 22: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

SETTIN

GLIM

ITS

Sivoia QEDTM Quiet Electronic Drive Window System 2.10

setting limits from controlsBasic ProgrammingSetting Limits Overview

The Open and Close Limits can be set from the EDU, aCCI, keypad or IR transmitter with at least: an Open, Close,Raise and Lower buttons.

The advantage of setting limits remotely from a keypad, IRtransmitter, or CCI, is these components are generallyeasier to access. Setting limits at the EDU may be simpler,and can be done before addressing the system, dependingupon the installation.

The Open and Close Limits determine how far an EDU willtravel. When the Open (Open) button is pressed on akeypad, IR transmitter, or CCI, the EDU will move to theOpen Limit. When the Close (Close) button is pressed on akeypad, IR transmitter, or CCI, the EDU will move to theClose Limit. The EDU will not move higher than the OpenLimit or lower than the Close Limit.

Notes:

• The system must be addressed in order to set limitsfrom a keypad, CCI, or IR transmitter.

• When setting limits from a keypad, IR transmitter or aCCI, each EDU will move approximately 200–250 mm(8–10 in) as it is selected. Be certain each EDU canmove this distance in each direction.

• Setting the Open Limit lower than the Close Limit willcause the blind to move down when raise is pressedand up when lower is pressed.

• Once EDUs have been assigned to keypads, CCIs, andIR receivers, limits can only be set on an EDU, usingthe keypads, CCIs, and IR receivers it is assigned to.

• Controls for integrating with other Lutron systems,including the SG-SVC/SO-SVC cannot address theSivoia QED system or set limits. These controls operateevery EDU.

• For information on how to set limits when usingkeypads that do not have Raise/Lower buttons, contactthe Lutron Technical Support at +44-(0)20-7702-0657.

Setting limits from the keypad, IR transmitter, or CCI needsto be done on if the limits have not already been set.Setting limits can also be done from the EDU, see page2.3

STEP 1

For the CCI, begin by setting switch 6 to OFF. Skip thisstep for keypads and IR transmitters.

Turn Switch 6OFF

Page 23: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

SETTIN

GLIM

ITS

Sivoia QEDTM Quiet Electronic Drive Window System 2.11

setting limits from controlsBasic Programming

LUTRON

STEP 2

Press and hold the Open (Open) and Raise buttonssimultaneously for 5 seconds to enter “Limit Set Mode.”For a keypad or CCI, the LED next to the Close (Close)button will flash quickly, and the LED next to the Open(Open) button will flash slowly.

Flashing LEDs

Press and hold theOpen (Open) andRaise buttons for 5seconds

Press and holdthe Open(Open) andRaise buttonsfor 5 seconds

Press and holdthe Open (Open)and Raise but-tons for 5 sec-onds

IR Transmitter IR Transmitter

Open

Close

Open

Preset

Close

LUTRON

STEP 3

Tap the Open (Open) button to select the desired EDU.Each time the Open (Open) button is tapped, the nextassigned EDU is selected. The selected EDU will beginraising and lowering over a short distance (fast cycle).Continue tapping the Open (Open) button until the desiredEDU is selected. Tapping the Close (Close) button selectsthe previous EDU.

Tap Open (Open)to select EDU

Tap Open(Open) to selectEDU

Tap Open(Open) toselect EDU

Open

Close

Open

Preset

Close

Page 24: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

OR

Technical Support :+44-(0)20-7702-0657

SETTIN

GLIM

ITS

Sivoia QEDTM Quiet Electronic Drive Window System 2.12

setting limits from controlsBasic Programming

LUTRON

STEP 4

Use the Raise and Lower buttons to move the selectedEDU to the desired limit position. When the Raise or Lowerbuttons are pressed, the EDU will stop fast cycling andbegin raising or lowering as long as the button is held.

Use Raise andLower to adjustEDU

Use Raise andLower to adjustEDU

Use Raiseand Lower toadjust EDU

Open

Close

Open

Preset

Close

LUTRON

STEP 5

Press and hold the Open (Open) button for 5 second tostore the current EDU position as the Open Limit. TheOpen (Open) LED will turn on steady for 2 seconds.

OR

Press and hold the Close (Close) button for 5 second tostore the current EDU position as the Close Limit. TheClose (Close) LED will turn on steady for 2 seconds.

Open

Close

Open

Close

Open

Preset

Close

LUTRON

Open

Preset

Close

Press and hold Open(Open) to set the Open

Limit

Press and hold Close(Close) to set the Close

Limit

Press and hold Open(Open) to set the Open

Limit

Press and hold Close(Close) to set the Close

Limit

Press and holdOpen (Open) to setthe Open Limit

OR

Press and holdClose (Close) to setthe Close Limit

OR

OR

Page 25: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

SETTIN

GLIM

ITS

Sivoia QEDTM Quiet Electronic Drive Window System 2.13

setting limits from controlsBasic Programming

LUTRON

STEP 6

Tap the Open (Open) button to select the next desiredEDU. Adjust the limits using the Raise and Lower buttonsas in step 4. Store the limits by pressing and holding theOpen (Open) or Close (Close) button as in step 5.

Tap Open (Open)to select EDU

Tap Open(Open) to selectEDU

Tap Open(Open) toselect EDU

Open

Close

Open

Preset

Close

LUTRON

STEP 7

Press and hold the Open (Open) and Raise buttonssimultaneously for 5 seconds to exit “Limit Set Mode.”

Press and hold theOpen (Open) andRaise buttons for 5seconds

Press and holdthe Open (Open)and Raise but-tons for 5 sec-onds

Press and holdthe Open (Open)and Raise but-tons for 5 sec-onds

Open

Close

Open

Preset

Close

Page 26: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

SETTIN

GLIM

ITS

Sivoia QEDTM Quiet Electronic Drive Window System 2.14

setting limits from controlsBasic ProgrammingSTEP 8

For the CCI, return switch 6 to ON. Skip this step forkeypads and IR transmitters.

Turn Switch 6OFF

If EDUs have not yet been assigned to keypads, IRreceivers, or CCIs, proceed to “Assigning EDUs” section.

Assigning EDUs to controls page 2.15Assigning EDUs to multi-group IR transmitter page 2.20

Page 27: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AS

SIG

NIN

GED

Us

Sivoia QEDTM Quiet Electronic Drive Window System 2.15

AS

SIG

NIN

GED

Us

AS

SIG

NIN

GED

Us

assigning EDUs to controlsBasic ProgrammingAssignment Overview

By default, after the system has been addressed, no EDUsare assigned to keypads, CCIs or IR Receivers.

Assignment determines which EDU will be operated byeach keypad, IR transmitter, and CCI. Assigning EDUs tokeypads, CCIs or IR Receivers is necessary to operate anindividual, or a user-defined group of EDUs, or all EDUs.

Assigning EDUs to a single keypad, CCI or IR Receiverdoes not affect which EDUs are operated by otherkeypads, CCIs or IR Receivers in the system.

Note:

• Entering “Assignment Mode” causes every EDU in thesystem to move between its Open and Close limits.Make certain that limits have been set appropriately foreach EDU in the system before entering “AssignmentMode.”

• Controls for integrating with other Lutron systems,including the SG-SVC/SO-SVC cannot address theSivoia QED system or set limits. These controls operateevery EDU.

• For information on how to assign inaccessible EDUs tokeypads that do not have Raise/Lower buttons, contactthe Lutron Technical Support at +44-(0)20-7702-0657.

• The CCI can be configured to accommodate multiplegroups of blinds (see page 2.44). Configurations otherthan the standard have Open and Close inputs inlocations other than inputs 1 and 5.

STEP 1

For the CCI only, begin by setting switch 6 to OFF. Skip thisstep for keypads, and IR transmitters.

For multi-group keypads and CCIs, choose the group onthe control to assign EDUs to. EDUs will need to beassigned to each group.

For more information on multi-group control from a CCI,refer to pages 2.44–2.45.

Turn Switch 6OFF

Open

Preset

Close

Open

Preset

Close

Page 28: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AS

SIG

NIN

GED

Us

Sivoia QEDTM Quiet Electronic Drive Window System 2.16

assigning EDUs to controlsBasic Programming

LUTRON

STEP 2

Press and hold the Open (Open) and Close (Close) buttonssimultaneously for 5 seconds. The LEDs next to the Open(Open) and Close (Close) buttons on the keypad or CCI willflash once per second.

Flashing LEDs

Press and hold theOpen (Open) andClose (Close) but-tons for 5 seconds

Press and holdthe Open (Open)and Close(Close) buttonsfor 5 seconds

Press and holdthe Open (Open)and Close (Close)buttons for 5seconds

IR Transmitter IR Transmitter

OPEN

CLOSE

Open

Preset

CloseTap the Close(Close) button

Flashing LED

Tap the Close(Close) button

Tap theClose (Close)button

OPEN

CLOSE

LUTRON

Open

Preset

Close

STEP 3

Tap the Close (Close) button to enter “Assignment Mode.”The LED next to the Close (Close) button will flash slowly(once per second). The LED next to the Open (Open) buttonwill turn off.

EDUs that are not assigned will move to their Open Limit.After the system is addressed for the first time, no EDUsare assigned to keypads, CCIs, or IR receivers.

EDUs that are assigned will move to their Close Limit.Assigned EDUs will be controlled by the keypad, IRreceiver, or CCI.

Page 29: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AS

SIG

NIN

GED

Us

Sivoia QEDTM Quiet Electronic Drive Window System 2.17

STEP 4

To select an individual EDU to assign or un-assign; tap theOpen (Open) button to select the desired EDU. Each timethe Open (Open) button is tapped, the next EDU will beselected. The selected EDU will begin raising and loweringover a short distance (fast cycle). Continue tapping theOpen (Open) button until the desired EDU is selected.Tapping the Close (Close) button selects the previous EDU.

assigning EDUs to controlsBasic Programming

Note: If desired, all EDUs can be quickly assigned orunassigned from a keypad.

To assign all EDUs in the system to a keypad, press andhold the Close (Close) button for 5 seconds.

To un-assign all EDUs in the system from a keypad, pressand hold the Open (Open) button for 5 seconds.

LUTRON

Tap Open (Open)to select EDU

Tap Open(Open) to selectEDU

Tap Open(Open) toselect EDU

Open

Close

Open

Preset

Close

Page 30: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AS

SIG

NIN

GED

Us

Sivoia QEDTM Quiet Electronic Drive Window System 2.18

assigning EDUs to controlsBasic Programming

For single group keypads that do not have raise and lower,such as the SQA-2D and the SQA-3D, EDUs can beassigned or un-assigned by tapping any button on the EDUwhile the keypad is in assignment mode. Tapping any EDUbutton toggles between assigned and unassigned. TheEDU will move to its Close Limit to indicate that it isassigned, or move to its Open Limit to indicate it is un-assigned.

For multi-group keypads and CCIs configured to operatemultiple groups of EDUs that do not have Raise or Lower,tap the Open (Open) button for one of the other groups toun-assign, tap the Close (Close) button for one of the othergroups to assign.

EDU Buttons

STEP 5

Tap the Lower button to assign the EDU that is currentlyselected (fast cycling). The currently selected EDU will beassigned and will move to its Close Limit.

To un-assign the currently selected EDU, tap the Raisebutton, the EDU will be un-assigned and will move to itsOpen Limit.

LUTRON

Tap Raise to un-assign the EDU

OR

Tap Lower to assignthe EDU

Tap Raise to un-assign the EDU

OR

Tap Lower toassign the EDU

Tap Raise to un-assign the EDU

OR

Tap Lower toassign the EDU

Open

Close

Open

Preset

Close

Open

Preset

Close

Open

Preset

Close

Page 31: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AS

SIG

NIN

GED

Us

Sivoia QEDTM Quiet Electronic Drive Window System 2.19

assigning EDUs to controlsBasic Programming

AS

SIG

NIN

GED

Us

AS

SIG

NIN

GED

Us

AS

SIG

NIN

GED

Us

LUTRON

STEP 6

Press and hold the Open (Open) and Close (Close) buttonssimultaneously for 5 seconds to exit “Assignment Mode.”Each EDU will return to the level it was at whenassignment mode was entered.

Press and hold theOpen (Open) andClose (Close) but-tons for 5 seconds

Press and holdthe Open (Open)and Close(Close) buttonsfor 5 seconds

Press and holdthe Open (Open)and Close(Close) buttonsfor 5 seconds

OPEN

CLOSE

Open

Preset

Close

STEP 7

For the CCI only, return switch 6 to ON. Skip this step forkeypads, and IR transmitters.

Enter Assignment Mode for other keypads, CCIs, and IRtransmitters in the system until all controls have EDUsassigned to them.

After EDUs have been assigned to all controls, set presetlevels for controls.

Adjusting Individual Levels page 2.24Storing Presets page 2.28.Assigning EDUs to multi-group IR transmitter page 2.20

Turn Switch 6ON

Page 32: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Assignment OverviewBy default, after the system has been addressed, no EDUsare assigned to keypads, CCIs or IR receivers.

Assignment determines which EDU will be operated byeach keypad, IR Transmitter, and CCI. Assigning EDUs tokeypads, CCIs or IR Receivers to operate an individual, ora user-defined group of EDUs, or all EDUs .

Assigning EDUs to a single keypad, CCI or IR Receiverdoes not affect which EDUs are operated by otherkeypads, CCIs or IR Receivers in the system.

Notes:

1. Entering “Assignment Mode” causes every EDU in thesystem to move between its Open and Close Limits. Makecertain that limits have been set appropriately for eachEDU in the system before entering “Assignment Mode.”

2. EDUs are assigned to IR Receivers, not IR Transmitters.For CCIs and keypads with IR Receivers, the IR Transmitteroperates the same EDUs that the CCI inputs or keypadbuttons operate.

3. The SVQ-4GD-IT operates a group of EDUs and 14 sub-groups. The SVQ-4S2G-IT operates a group of EDUs and 2sub-groups. The SVQ-4S2G-IT also operates LutronGRAFIK Eye, HomeWorks and Telume lighting controls.

For SVQ-4GD-IT and SVQ-4S2G-ITTransmitters:Assigning EDUs to an IR Receiver

The SVQ-4GD-IT and SVQ-4S2G-IT IR transmitters allowthe user to operate a group of EDUs or select a smallersub-group of EDUs to operate.

The SVQ-4GD-IT is designed to accommodate multiplewindows with dual blinds (e.g. sheer and dark) or curtains.The buttons at the top of the transmitter allow the user toopen, close, raise, or lower the selected blinds. The middleset of buttons is used to select either the sheer, dark, orboth sheer and dark blinds to operate in a dual mountapplication. The lower set of buttons are used to selectwindows 1 through 4 or all windows that the EDUs areinstalled on.

The SVQ-4S2G-IT is designed to accommodate two groupsof blinds and a Lutron lighting control system. The buttonsat the top of the transmitter allow the user to open, close,raise, or lower the selected blinds. The middle set ofbuttons is used select blind sub-group 1 or 2, or both sub-groups 1 and 2. The lower set of buttons are used toselect a lighting scene on a Lutron lighting control system.

Technical Support :+44-(0)20-7702-0657

AS

SIG

NIN

GED

Us

Sivoia QEDTM Quiet Electronic Drive Window System 2.20

assigning EDUs to multi-group IR transmitters

Basic Programming

SV-IRInfrared remoteeye (connects to

an EDU)Keypad with IR

ReceiverContactClosure

Interface (CCI)

Open

Preset 1

Close

Preset 2

IR receivers are available:

Page 33: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AS

SIG

NIN

GED

Us

Sivoia QEDTM Quiet Electronic Drive Window System 2.21

assigning EDUs to multi-group IR transmitters

Basic Programming

AS

SIG

NIN

GED

Us

AS

SIG

NIN

GED

Us

AS

SIG

NIN

GED

Us

STEP 1

Enter “Programming Mode” pressing and holding the Open(Open) and Close (Close) buttons on IR Transmittersimultaneously for 5 seconds.

OPEN

CLOSE

Both

WINDOW

1

3 4

2 All

SHADE

Press and holdthe Open

(Open) andClose (Close)buttons for 5

seconds

STEP 3

Enter “Assignment Mode” by tapping the Close (Close)button. EDUs that are assigned to the IR Receiver in“Assignment Mode” will move to their Close Limit. EDUsthat are not assigned to the IR Receiver in “AssignmentMode” will move to their Open Limit.

SVQ-4GD-ITPress the All (All) andBoth (Both) buttons

ORSVQ-4S2G-IT

Press the Both (Both)button

OPEN

CLOSE

Both

WINDOW

1

3 4

2 All

SHADE

OPEN

CLOSE

Both

WINDOW

1

3 4

2 All

SHADE

Tap Close(Close)

STEP 2

Select the group to assign EDUs to. For the SVQ-4GD-OCITpress the All (All) and Both (Both) buttons. For the SVQ-4S2G-IT press the Both (Both) button.

Page 34: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AS

SIG

NIN

GED

Us

Sivoia QEDTM Quiet Electronic Drive Window System 2.22

assigning EDUs to multi-group IR transmitters

Basic Programming

STEP 5

To select an individual EDU to assign or un-assign; tap theOpen (Open) button to select the desired EDU. Each timethe Open (Open) button is tapped, the next EDU will beselected. The selected EDU will begin raising and loweringover a short distance (fast cycle). Continue tapping theOpen (Open) button until the desired EDU is selected.Tapping the Close (Close) button selects the previous EDU.

OPEN

CLOSE

Both

WINDOW

1

3 4

2 All

SHADE

Tap Open(Open) toselect EDU

STEP 4

Assign or un-assign EDUs as desired. By default, no EDUsare assigned to IR Receivers.

In order to assign all EDUs in the system, aim the IRTransmitter at the IR Receiver and press and hold theClose (Close) button for 5 seconds.

In order to un-assign all EDUs in the system, aim the IRTransmitter at the IR Receiver and press and hold theOpen (Open) button for 5 seconds.

OPEN

CLOSE

Both

WINDOW

1

3 4

2 All

SHADE

OPEN

CLOSE

Both

WINDOW

1

3 4

2 All

SHADE

Press and holdClose (Close)to assign all

EDUs to this IRReceiver

OR

Press and holdOpen (Open) toun-assign all

EDUs to this IRReceiver

Page 35: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AS

SIG

NIN

GED

Us

Sivoia QEDTM Quiet Electronic Drive Window System 2.23

assigning EDUs to multi-group IR transmitters

Basic Programming

AS

SIG

NIN

GED

Us

AS

SIG

NIN

GED

Us

AS

SIG

NIN

GED

Us

STEP 6

Assign or un-assign the currently selected EDU using theRaise and Lower buttons.

To assign an EDU, tap the Lower button.

To un-assign an EDU, tap the Raise button

STEP 7

Exit “Assignment Mode” by pressing and holding the Open(Open) and Close (Close) buttons simultaneously for 5seconds. Each EDU will return to the level it was at when“Assignment Mode” was entered.

OPEN

CLOSE

Both

WINDOW

1

3 4

2 All

SHADE

OPEN

CLOSE

Both

WINDOW

1

3 4

2 All

SHADE

Use Raiseand Lower toassign andun-assign

Press andhold the Open

(Open) andClose (Close)buttons for 5

seconds

STEP 8

Press and hold Open (Open) and Close (Close) for 5seconds.

STEP 9

Select a sub-group to assign EDUs to. For the SVQ-4S2Gselect sub-group 1 by pressing “Shades (Shades) 1”. Forthe SVQ-4GD-OCIT, select “dark shades/window 1” sub-group by pressing the “dark shades” ( ) and “Window(Window) 1” buttons.

STEP 10

Tap Close (Close) to enter assignment mode for theselected sub-group.

STEP 11

Press and release Open (Open) to select EDU to assign orunassign. Selected EDU will fast cycle.

STEP 12

To assign the selected EDU, tap Lower. To unassign theselected EDU, tap Raise.

STEP 13

Press and hold Open (Open) and Close (Close) for 5seconds to exit assignment mode.

STEP 14

Select the next sub-group.

For SVQ-4S2G, repeat steps 9-13, this time selecting sub-group 2 in step 9.

For SVQ-4GD-OCIT, repeat steps 9-13, each time throughselecting a different sub-group such as “sheershades/window 1.” Continue until EDUs have beenassigned to each sub-group.

Page 36: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AS

SIG

NIN

GED

Us

Sivoia QEDTM Quiet Electronic Drive Window System 2.24

adjusting individual levelsBasic ProgrammingIndividual Level Adjust Overview

Sivoia QED EDUs have the ability to store positions aspresets that can be accessed from keypads, CCIs, and IRTransmitters. Pressing a preset button recalls stored levelsfor each of the EDUs operated by the preset button.

Sivoia QED keypads, CCIs, and IR Transmitters have theability to adjust the levels of EDUs individually. This way,the user can push one preset button and recall uniquepreset levels for individual EDUs.

“Individual Level Adjust Mode” allows an installer to selectindividual EDUs that have been assigned to a keypad, CCI,or IR Receiver and change the EDU to the desired level.Once the EDUs are at the desired levels, the installer canthen exit “Individual Level Adjust Mode” and store thecurrent levels by pressing and holding a preset button.

Notes:

1. The system must be addressed and EDUs must beassigned to a keypad, CCI, or IR Receiver in order to use“Individual Level Adjust.”

2. While using “Individual Level Adjust,” each EDU canmove approximately 200–250 mm (8–10 in) as it isselected. Be certain that the limits have been setappropriately.

3. For information on how to adjust the levels of individualEDUs when using keypads that do not have Raise/Lowerbuttons, contact the Lutron Technical Support at +44-(0)20-7702-0657.

STEP 1

For the CCI only, begin by setting switch 6 to OFF. Skip thisstep for keypads, and IR transmitters.

Turn Switch 6OFF

Page 37: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AS

SIG

NIN

GED

Us

Sivoia QEDTM Quiet Electronic Drive Window System 2.25

adjusting individual levelsBasic Programming

LUTRON

STEP 2

Press and hold the Open (Open) and Lower buttonssimultaneously for 5 seconds to enter “Individual LevelAdjust Mode.” For a keypad or CCI, the LED next to theClose (Close) button will flash quickly, and the LED next tothe Open (Open) button will flash slowly.

Flashing LEDs

Press and hold theOpen (Open) andLower buttons for 5seconds

Press and holdthe Open (Open)and Lower but-tons for 5 sec-onds

Press and holdthe Open (Open)and Lower but-tons for 5 sec-onds

IR Transmitter IR Transmitter

Open

Close

Open

Preset

Close

LUTRON

STEP 3

Tap the Open (Open) button to select the desired EDU.Each time the Open (Open) button is tapped the nextassigned EDU is selected. The selected EDU will beginraising and lowering over a short distance (fast cycle).Continue tapping the Open (Open) button until the desiredEDU is selected. Tapping the Close (Close) button selectsthe previous EDU.

Press Open(Open) to selectEDU

Press Open(Open) to selectEDU

Press Open(Open) toselect EDU

Open

Close

Open

Preset

Close

Page 38: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AS

SIG

NIN

GED

Us

Sivoia QEDTM Quiet Electronic Drive Window System 2.26

adjusting individual levelsBasic Programming

LUTRON

STEP 4

Use the Raise and Lower buttons to move the selectedEDU to the desired position. When the Raise or Lowerbuttons are pressed, the EDU will stop fast cycling andbegin raising or lowering as long as the button is held.

Use Raise andLower to adjustEDU

Use Raise andLower to adjustEDU

Use Raiseand Lower toadjust EDU

Open

Close

Open

Preset

Close

LUTRON

STEP 5

Tap the Open (Open) button to select the next desiredEDU. Adjust the position using the Raise and Lowerbuttons as in step 4.

Press Open(Open) to selectEDU

Press Open(Open) to selectEDU

Press Open(Open) toselect EDU

Open

Close

Open

Preset

Close

Page 39: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AS

SIG

NIN

GED

Us

Sivoia QEDTM Quiet Electronic Drive Window System 2.27

adjusting individual levelsBasic Programming

LUTRON

STEP 6

Press and hold the Open (Open) and Raise buttonssimultaneously for 5 seconds to exit “Individual LevelAdjust Mode.”

Press and hold theOpen (Open) andLower buttons for 5seconds

Press and holdthe Open (Open)and Lower but-tons for 5 sec-onds

Press and holdthe Open (Open)and Lower but-tons for 5 sec-onds

Open

Close

Open

Preset

Close

STEP 7

For the CCI, return switch 6 to ON. Skip this step forkeypads and IR transmitters.

Turn Switch 6OFF

After leaving “Individual Level Adjust Mode,” refer to page2.28 for information on how to store the current EDUpositions as a preset.

Page 40: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

PR

ESETS

Sivoia QEDTM Quiet Electronic Drive Window System 2.28

storing presetsBasic ProgrammingSivoia QED EDUs have the ability to store positions aspresets, accessible from keypads, CCIs, and IRtransmitters.

STEP 1

For the CCI only, begin by setting switch 6 to OFF. Skip thisstep for keypads, and IR transmitters.

LED next tothe selectedPreset willflash andthen turn ON

STEP 2

Store the EDUs current position as a preset by pressingand holding the desired Preset (Preset) button for 5seconds. The LED next to the Preset (Preset) button willflash, and then turn on, indicating the preset has beenstored.

Note: Current position is stored as a preset only on theEDUs that are operated by that Preset (Preset) button.

Turn Switch 6OFF

LUTRON

Open

Preset

Close

Page 41: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

PR

ESETS

Sivoia QEDTM Quiet Electronic Drive Window System 2.29

storing presetsBasic ProgrammingSTEP 3

For the CCI only, return switch 6 to ON. Skip this step forkeypads, and IR transmitters.

Turn Switch 6ON

Page 42: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

PR

ESETS

Sivoia QEDTM Quiet Electronic Drive Window System 2.30

locking presetsBasic Programming

Unlocking presets from a keypad

STEP 1

Unlock presets by pressing and holding Open (Open) andPreset (Preset) 1 buttons for 5 seconds. All LEDs on thekeypad will flash once, indicating presets have beenunlocked.

Note: This unlocks all presets on every keypad in thesystem.

Presets can be “locked” to prevent accidental re-programming of presets. All presets on every keypad canbe locked from a single keypad.

Locking presets from a keypad

STEP 1

Lock presets by pressing and holding Open (Open) andPreset (Preset) 1 buttons for 5 seconds. All LEDs on thekeypad will flash rapidly for one second (8 times persecond), indicating presets have been locked.

Note: This locks all presets on every keypad in thesystem.

LUTRON

Open

Preset

Close

LUTRON

Open

Preset

Close

Page 43: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AD

VAN

CED

PR

OG

RA

MM

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.31

AD

VAN

CED

PR

OG

RA

MM

ING

AD

VAN

CED

PR

OG

RA

MM

ING

AD

VAN

CED

PR

OG

RA

MM

ING

AD

VAN

CED

PR

OG

RA

MM

ING

Components can be added to the Sivoia QED system atany time, up to a maximum of 96 total devices (EDUs,keypads, and CCIs). Adding components does not affectthe programming of already installed components.

Note: Do not add previously addressed components, orcombine two previously addressed systems withoutrestoring all components to factory default settings.

To add a keypad or CCI to the system

STEP 1

Install the new keypad or CCI as described in theinstallation instructions. Connect the keypad or CCI to thecommunications link.

Note: When keypads or CCIs are added, they will operateall of the EDUs on the communication link until the systemis addressed.

STEP 2

Address the system. Refer to the section of this manualon “Addressing,” page 2.6 or 2.32.

Note: Addressing must be done with the entire systempowered and wired to the communications link.

STEP 3

Assign EDUs to the keypad or CCI. Refer to the section ofthis manual on “Assigning EDUs to Controls,” page 2.15.

To add an EDU to the system

STEP 1

Install the new EDU as described in the installationinstructions. Connect the EDU to the communications linkand power supply.

Note: When EDUs are added, they will not respond to anykeypad or CCI on the communication link by default.

STEP 2

Address the system. Refer to the section of this manual on“Addressing,” page 2.6 or 2.32.

STEP 3

Set the limits for the new EDU. Refer to the section of thismanual on “Setting Limits,” page 2.10.

STEP 4

Assign the new EDU to keypads, CCIs, or IR Transmitters.Refer to the section of this manual on “Assigning EDUs,”page 2.15.

adding componentsAdvancedProgramming

Page 44: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AD

DR

ESS

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.32

addressing from the EDUBasic ProgrammingAddressing Overview

Each keypad, EDU, and CCI in the system must have aunique address in order to store presets. Addressing thesystem gives each device a unique address number, whichallows individual components to communicate properly.

Each device can be given a unique address automatically,by placing a single keypad, EDU, IR transmitter, or CCI in“Addressing Mode.” The device in Addressing Mode willthen allocate a unique address to every keypad, EDU, andCCI in the system.

The Sivoia QED system is addressed using a singlekeypad, EDU, CCI, or IR transmitter. It is not necessary toenter address mode on more than 1 device in the system.For convenience, address the system from the componentthat is easiest to access.

The system should be addressed each time newcomponents are added. Addressing a previouslyprogrammed system will not erase any previousprogramming, addresses, limits, EDU assignments, orpresets.

After addressing a new system, keypads, CCIs, and IRtransmitters will not operate any EDU.

Once the system has been addressed, EDUs need to beassigned to the appropriate keypads, CCIs and IRreceivers.

Notes:

• The system should be addressed after all componentshave been installed, wired to the communications link,and powered.

• To add previously addressed components to an existingsystem, or to connect a previously addressed systemto an existing system, return components to factorydefaults before wiring them to the existing system(refer to Advanced Programming).

Addressing from the EDU needs to be done only if thesystem has not already been addressed from a keypad,CCI, or IR transmitter.

STEP 1

Enter “Addressing Mode” by pressing and holding the“Close Limit Button” ( ) on the EDU for 5 seconds. TheLED on a roller blind EDU will flash quickly for twoseconds then turn on (steady LED), indicating the EDU isready to begin addressing. The display on a curtain trackEDU will show ( ).

Press and holdthe Close LimitButton for 5 sec-onds

Steady LED

Tubular EDU

External EDU

Page 45: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

LUTRON

Open

Preset

Close

Technical Support :+44-(0)20-7702-0657

AD

DR

ESS

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.33

addressing from the EDUBasic Programming

AD

DR

ESS

ING

AD

DR

ESS

ING

AD

DR

ESS

ING

STEP 3

Wait for addressing to be completed. This will takeapproximately one minute. Proper communicationsbetween devices can be confirmed during the addressingprocess.

While addressing is in progress, each keypad and CCI willflash its Open (Open) LED quickly (8 times per second).Each roller blind EDU will flash its LED quickly (8 times persecond). Each curtain track EDU display will flash ( )(8 times per second).

When addressing has successfully completed, Open(Open) and Close (Close) LEDs on every keypad and CCIwill flash slowly (1 flash per second). The LED on the EDUwill flash slowly (1 flash per second).

Correct wiring can be confirmed by checking that eachkeypad, CCI, and EDU is flashing its LED. If a device doesnot flash its LED, wait for addressing to complete, checkwiring, and re-address the system, entering addressingmode from the same device that was previously used toaddress the system.

Flashing LED

Flashing LEDs

STEP 2

Initiate system addressing by taping the “adjust anti-clockwise button” ( ) button. The LED on roller blinds willbegin to flash quickly (8 times per second). The display oncurtain tracks will flash ( ) (8 times per second). Thesystem is now automatically addressing.

Tap the AdjustAnti-clockwiseButton

Flashing LED

Page 46: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AD

DR

ESS

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.34

addressing from the EDUBasic ProgrammingSTEP 4

Exit “Addressing Mode” when addressing is complete bypressing and holding the “Close Limit Button” on the EDUfor 5 seconds. LED will turn off.

After the system has been addressed, set the limits if theyhave not already been set. After addressing the systemand setting limits, assign EDUs to each keypad, CCI, andIR receiver.

Setting limits from the EDU page 2.3Setting limits from controls page 2.10Assigning EDUs to controls page 2.15Assigning EDUs to multi-group IR transmitter page 2.20

Press and holdthe Close LimitButton for 5 sec-onds

Page 47: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

restoring keypads and CCIs to default settings

Technical Support :+44-(0)20-7702-0657

AD

VAN

CED

PR

OG

RA

MM

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.35

AD

VAN

CED

PR

OG

RA

MM

ING

AD

VAN

CED

PR

OG

RA

MM

ING

AD

VAN

CED

PR

OG

RA

MM

ING

AD

VAN

CED

PR

OG

RA

MM

ING

AD

VAN

CED

PR

OG

RA

MM

ING

Restoring a keypad, CCI, or EDU to its Factory DefaultSettings will erase all current programming for thedevice. Do not do this unless you are certain that it isnecessary. For more information contact the LutronTechnical Support at +44-(0)20-7702-0657.

Returning an EDU to its Factory Default Settings does noterase the upper and lower limit settings. All otherprogramming in the EDU is erased when it’s returned tothe Factory Default Settings.

Returning a Keypad or CCI to its FactoryDefault SettingSTEP 1

For the CCI only, begin by setting switch 6 to OFF. Skip thisstep for keypads.

AdvancedProgramming

STEP 2

Simultaneously press and hold the Open (Open) and Close(Close) buttons for 5 seconds. The LEDs next to the Open(Open) and Close (Close) buttons will flash.

Turn Switch 6OFF

LUTRON

Flashing LEDs

Press and hold theOpen (Open) andClose (Close) buttonsfor 5 seconds

Press and holdthe Open (Open)and Close(Close) buttonsfor 5 seconds

Open

Preset

Close

Page 48: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AD

VAN

CED

PR

OG

RA

MM

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.36

AdvancedProgramming

restoring keypads and CCIs to default settings

STEP 2

Press and hold the Open (Open) button for 5 seconds. TheLEDs next to the Open (Open) and Close (Close) buttonswill flash quickly for 2 seconds then flash slowly.

STEP 3

Press and hold the Close (Close) button for 5 seconds. TheLEDs next to the Open (Open) and Close (Close) buttonswill flash quickly for 2 seconds then flash slowly.

LEDs will flashquickly for 2 sec-onds then flashslowly

LEDs will flashquickly for 2 sec-onds then flashslowly

LUTRON

Open

Preset

Close

LUTRON

Open

Preset

Close

Press Open (Open)button for 5 sec-onds

Press Open (Open)button for 5 sec-onds

Press Close(Close) button for5 seconds

Press Close (Close)button for 5 sec-onds

Page 49: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AD

VAN

CED

PR

OG

RA

MM

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.37

restoring keypads and CCIs to default settings

AdvancedProgramming

AD

VAN

CED

PR

OG

RA

MM

ING

AD

VAN

CED

PR

OG

RA

MM

ING

AD

VAN

CED

PR

OG

RA

MM

ING

AD

VAN

CED

PR

OG

RA

MM

ING

STEP 4

Simultaneously press and hold the Open (Open) and Close(Close) buttons for 5 seconds. The LEDs will turn ONsteady then turn OFF. The keypad is now restored toFactory Default Settings.

All LEDs turn ONand then OFF

LUTRON

Open

Preset

Close

Simultaneouslypress and hold theOpen (Open) andClose (Close) but-tons for 5 seconds

Simultaneouslypress and hold theOpen (Open) andClose (Close) but-tons for 5 seconds

STEP 5

For the CCI only, return switch 6 to ON. Skip this step forkeypads.

Turn Switch 6ON

Page 50: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AD

VAN

CED

PR

OG

RA

MM

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.38

AdvancedProgramming

restoring entire system to default settings

Returning the entire system to FactoryDefault SettingRestoring the entire system to its Factory DefaultSettings will erase all current programming for everydevice on the communications link. Do not do thisunless you are certain that it is necessary. For moreinformation contact the Lutron Technical Support at +44-(0)20-7702-0657.

Returning the entire system to its Factory Default Settingsdoes not erase the Open and Close limit settings. All otherprogramming is erased. The system will need to beaddressed, and EDUs assigned to controls after it hasbeen restored to Factory Default Settings.

Restoring the entire system to Factory Default Settingsfrom a keypad or CCI is intentionally difficult to do in orderto prevent accidentally restoring the system to FactoryDefault Settings.

STEP 1

For the CCI only, begin by setting switch 6 to OFF. Skip thisstep for keypads.

Turn Switch 6OFF

STEP 2

For keypads, remove the wallplate and set switch 8 toOFF. For CCIs, set switch 8 to OFF. The LEDs will begin toscroll. Place the wallplate back onto the keypad.

Turn Switch 8OFF

Turn Switch 8OFF

Page 51: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AD

VAN

CED

PR

OG

RA

MM

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.39

restoring entire system to default settings

AdvancedProgrammingSTEP 3

Simultaneously press and hold the Open (Open) and Close(Close) buttons for 5 seconds. The LEDs next to the Open(Open) and Close (Close) buttons will flash once persecond.

LUTRON

Flashing LEDs

Press and hold theOpen (Open) andClose (Close) but-tons for 5 seconds

Press and holdthe Open (Open)and Close(Close) buttonsfor 5 seconds

Open

Preset

Close

STEP 4

Press and hold the Open (Open) button for 5 seconds. TheLEDs next to the Open (Open) and Close (Close) buttonswill flash quickly for 2 seconds, then return to flashingonce per second.

LEDs will flashquickly for 2 sec-onds then flashslowly

LUTRON

Open

Preset

Close

Press and hold theOpen (Open) but-ton for 5 seconds

Press and hold theOpen (Open) but-ton for 5 seconds

Page 52: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AD

VAN

CED

PR

OG

RA

MM

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.40

AdvancedProgramming

restoring entire system to default settings

STEP 5

Press and hold the Close (Close) button for 5 seconds. TheLEDs next to the Open (Open) and Close (Close) buttonswill flash quickly for 2 seconds, then return to flashingonce per second.

LEDs will flashquickly for 2 sec-onds then flashslowly

LUTRON

Open

Preset

Close

Press and hold theClose (Close) but-ton for 5 seconds

Press and hold theClose (Close) but-ton for 5 seconds

STEP 6

Press and hold the Open (Open) button for 5 seconds. TheLEDs next to the Open (Open) and Close (Close) buttonswill flash quickly for 2 seconds, then return to flashingonce per second.

LEDs will flashquickly for 2 sec-onds then flashslowly

LUTRON

Open

Preset

Close

Press and hold theOpen (Open) but-ton for 5 seconds

Press and hold theOpen (Open) but-ton for 5 seconds

Page 53: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AD

VAN

CED

PR

OG

RA

MM

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.41

restoring entire system to default settings

AdvancedProgrammingSTEP 7

Simultaneously press and hold the Open (Open) and Close(Close) buttons for 5 seconds. The LEDs next to the Open(Open) and Close (Close) buttons will flash once persecond on all keypads and CCIs. EDUs will flash greenLED.

(Note: This step must be repeated – see step 8)

LUTRON

Flashing LEDs

Press and hold theOpen (Open) andClose (Close) but-tons for 5 seconds

Press and hold theOpen (Open) andClose (Close) but-tons for 5 seconds

Open

Preset

Close

STEP 8

Simultaneously press and hold the Open (Open) and Close(Close) buttons for 5 seconds. All LEDs on the control willturn on briefly.

LUTRON

Flashing LEDs

Press and hold theOpen (Open) andClose (Close) but-tons for 5 seconds

Press and hold theOpen (Open) andClose (Close) but-tons for 5 seconds

Open

Preset

Close

Page 54: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AD

VAN

CED

PR

OG

RA

MM

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.42

AdvancedProgramming

restoring entire system to default settings

STEP 9

For keypads, remove the wallplate and set switch 8 to ON.For CCIs, switch 8 should be set to ON. The LEDs will stopscrolling. Place the wallplate back onto the keypad.

Turn Switch 8ON

Turn Switch 8ON

STEP 10

For the CCI only, return switch 6 to ON. Skip this step forkeypads.

The entire Sivoia QED system has now been returned tofactory defaults. Address the system, and assign EDUs tocontrols.

Turn Switch 6ON

Page 55: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AD

VAN

CED

PR

OG

RA

MM

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.43

Returning an EDU to its Factory Default Setting

STEP 1

Press and hold the Close Limit button on the EDU for 5seconds. The LED on the EDU will flash then turn ONsteady.

STEP 2

Press and hold the Open Limit button for 5 seconds. TheLED on the EDU will flash then turn ON steady.

STEP 3

Press and hold the clockwise button for 5 seconds. TheLED on the EDU will flash then turn ON steady.

STEP 4

Press and hold the anti-clockwise button for 5 seconds.The LED on the EDU will flash. The EDU is now restored toFactory Default Settings.

Close Limit Button

Open Limit ButtonAnti-clockwiseButton

Clockwise Button

restoring EDU to default settingsAdvancedProgramming

Page 56: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AD

VAN

CED

PR

OG

RA

MM

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.44

AdvancedProgramming multiple groups with the CCIControlling multiple groups from a single CCI

As shipped, the CCI allows control of a single group ofEDUs from an external device using the functionalityshown below. A single CCI can be configured to operatemultiple groups of EDUs.

Notes:

1. Changing a CCIs configuration will erase the currentprogramming.

2. The IR receiver on the CCI is disabled in anyconfiguration other than the Standard Configuration.

STEP 1

Determine the desired functionality.

Standard Configuration: This provides three presets andraise/lower, but can only operate a single group of EDUs.

Open/Close Configuration: This will enable the CCI to Openor Close up to four groups of EDUs, but does not providepresets or raise/lower.

Open/Close/Raise/Lower Configuration: This will enablethe CCI to Open, Close, Raise, and Lower up to two groupsof EDUs, but does not provide presets.

Open/Preset/Close/Stop Configuration: This will enable theCCI to Open, Close, or Stop up to two groups of EDUs, aswell as having access to a single preset for each group,but does not provide raise/lower.

Standard Configuration

Open

Preset 2

Preset 3

Preset 1

Close

Raise

Switch Settings

Lower

Stop

Open/Close Configuration

Open

Open

Close

Close

Open

OpenClose

Close

Group 1

Group 4

Group 2

Group 3

STEP 2

Set the switches.

Locate the switches on the CCI. The switch position willdetermine the configuration options. Set the switchesaccording to the diagrams below and on the next page.

Switch Settings

Page 57: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AD

VAN

CED

PR

OG

RA

MM

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.45

multiple groups with the CCIAdvancedProgramming

AD

VAN

CED

PR

OG

RA

MM

ING

AD

VAN

CED

PR

OG

RA

MM

ING

AD

VAN

CED

PR

OG

RA

MM

ING

AD

VAN

CED

PR

OG

RA

MM

ING

AD

VAN

CED

PR

OG

RA

MM

ING

STEP 3

Apply the new configuration.

Follow the steps in the section “Restoring keypads andCCIs to Default Settings” on pages 2.35–2.37, in order toapply the new configuration. Make sure to use the newOpen and Close buttons.

STEP 4

Program the Sivoia QED system.

The CCI has now taken on the new configuration. Addressthe Sivoia QED system, set limits if they have not alreadybeen set, and assign EDUs to each group on the CCI. Forconfigurations other than the standard CCI configuration,use each group’s Open/Close inputs to enter “AssignmentMode” for each individual group.

Note: For Open/Close and Open/Preset/Close/Stopconfigurations, the Open and Close buttons of the othergroups can be used to Unassign or Assign EDUs (in theabsence of the Raise or Lower buttons).

STEP 2 (continued)

Open/Preset/Close/Stop Configuration

Open

Close

Stop

Preset

Open

CloseStop

Preset

Group 1

Group 2

Open/Close/Raise/Lower Configuration

Open

Raise

Lower

Close

Open

RaiseLower

Close

Group 1

Group 2

Switch Settings

Switch Settings

Page 58: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

AD

VAN

CED

PR

OG

RA

MM

ING

Sivoia QEDTM Quiet Electronic Drive Window System 2.46

AdvancedProgramming notes

Page 59: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

Troubleshooting

Sivoia QEDTM Quiet Electronic Drive Window System 3.1

Page 60: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

TRO

UB

LESH

OO

TING

Sivoia QEDTM Quiet Electronic Drive Window System 3.2

TroubleshootingElectronic Drive Unit (EDU) will not move

• EDU is not powered – check EDU power

• Roller blind fabric is caught on something – Check that roller blind fabric is not caught on something or binding

• EDU is not assigned to keypad, IR transmitter, or CCI

• Limits are set to the same position

EDU does not fully open or fully close

• Presets have been set incorrectly – try using raise and lower buttons

• Limits have been set incorrectly – refer to "setting limits" on page 2.3 or 2.10

• Roller blind fabric is caught on something – free roller blind

Roller blind moves up when pressing lower button, and down when pressing raise button

• Open and close limits have been reversed – refer to "setting limits" on page 2.3 or 2.10

Fabric not level

• Adjust using level adjustment screw

• Check that brackets are mounted level

• Check that fabric is tracking correctly on the roller blind tube

Fabric not centred over window

• Centre roller blind using centre adjustment

• Check that brackets are centred

• Check that fabric is tracking correctly on the tube

Roller blind does not move smoothly

• Check for binding of roller blind fabric on side channels, fascia, etc

• Check fabric tracking

Keypad LEDs are off, keypad will not control any roller blind

• Check that keypad is powered

Page 61: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

Technical Support :+44-(0)20-7702-0657

TRO

UB

LESH

OO

TING

Sivoia QEDTM Quiet Electronic Drive Window System 3.3

Keypad LEDs are lit, but keypad will not operate any blind

• All presets have been set to same height – try using raise/lower buttons at keypad

• Communications Link not wired to EDU – check wiring

• EDU has been un-assigned from keypad – refer to "assignment" section

Keypads will not operate blind, IR works properly

• Check that keypad is powered

• Keypad is not wired correctly – check wiring

• EDU has been un-assigned from keypad. Refer to "assignment" section

• Presets are all programmed to same location, try using raise/lower at keypad

Cannot store presets

• Preset lock is enabled

• Presets are being accidently re-programmed – set presets, enable preset lock

Keypad does not operate all the blinds it is assigned to

• EDU has been unassigned from keypad – refer to "assignment" section

• EDU has all presets set to same height, try raise/lower

• EDU is not wired correctly

• Keypad is not wired correctly

IR controls will not operate blind, keypads work properly

• IR transmitter does not have line of sight to IR receiver

• Out of range – move to within 9 m (30 ft) of IR receiver

• EDU has been unassigned to IR receiver – refer to "assignment" section

• IR receiver not properly installed on EDU

Blinds in a room move on their own

• EDUs are assigned to control in another room – refer to "assignment" section

Page 62: 045-101-12a QED wiring guide - Lutron Electronics · 10 m 2(110 ft ) of fabric. Technical Support : +44-(0)20-7702-0657 WIRING Sivoia QEDTM Quiet Electronic Drive Window System 1.5

To Contact Lutron:

WORLD HEADQUARTERSLutron Electronics Co., Inc.7200 Suter RoadCoopersburg, PA 18036United StatesTel: +1-610-282-3800Fax:+1-610-282-1243

CUSTOMER SERVICE/ORDERINGUK +44-(0)20-7702-0657 – 09.00 - 18.00 GMTUSA +1-610-282-3800 – 08.00 - 20.00 EST

CUSTOMER SERVICE/[email protected]

TECHNICAL SUPPORT & SERVICESUK +44-(0)20-7702-065709.00 - 18.00 GMTUSA +1-610-282-3800 – 24 hours/7 daysINTERNETwww.lutron.com

ADDITIONAL LUTRON SALES OFFICES LOCATED IN :United Kingdom Tel: +44-(0)20-7702-0657 Fax: +44-(0)20-7480-6899 FREEPHONE (UK) 0800-282-107Germany Tel: +49-309-710-4590 Fax: +49-309-710-4591 FREEPHONE 00800-5887 6635France Tel: +33-(0)1-44-70-71-86 Fax: +33-(0)1-44-70-70-97 FREEPHONE 0800-90-12-18Spain-Madrid Tel: +34-91-567-84-79 Fax: +34-91-567-84-78 FREEPHONE 0900-948-944Spain-Barcelona Tel: +34-93-496-57-42 Fax: +34-93-496-57-50 FREEPHONE 0900-948-944Hong Kong Tel: +852-2104-7733 Fax: +852-2104-7633Beijing Tel: +86-10-5877-1817 Fax: +86-10-5877-1816Shanghai Tel: +86-21-6288-1473 Fax: +86-21-6288-1751Singapore Tel: +65-6220-4666 Fax: +65-6220-4333Japan Tel: +81-3-5575-8411 Fax: +81-3-5575-8420

EUROPEAN HEADQUARTERSLutron EA Ltd.6 Sovereign CloseLondon, E1W 3JFUnited KingdomTel: +44-(0)20-7702-0657Fax: +44-(0)20-7480-6899

©2005 Lutron Electronics Co., Inc.Made and printed in the U.S.A.P/N 045-101-12 Rev. A 1/05