04 Migrationtesting_Pitzl

Embed Size (px)

Citation preview

  • 7/30/2019 04 Migrationtesting_Pitzl

    1/29

    sterreichisches Forschungsinstitutfr Chemie und Technik

    www.ofi.at

    CROPACK 2010

    Migration Testing Overall migration SML tests Screening methods

    DI Michael Pitzl

  • 7/30/2019 04 Migrationtesting_Pitzl

    2/29

    www.ofi.at

    2

    Private Testing and Research Institute

    Legal form:Association / Ltd.

    ~ 130 employees(status: 12/2009) ~ 7.000 m2 floor space at 2 locations

    Business Year 2009:

    Annual turnover: 13,8 Mio. Euro

    R&D: ~ 26 %

    Share of export: ~ 24 %

    Organisation and Facts

  • 7/30/2019 04 Migrationtesting_Pitzl

    3/29

    www.ofi.at

    3

    Location Arsenal1030 Vienna, Arsenal Objekt 213,Franz Grill-Strae 5

    Applied Polymer Technology

    Varnishes and Adhesives

    Construction

    Sports Technology

    Location Brehmstrae1110 Vienna, Brehmstrae 14a

    Packaging

    Medical Products

    Eco Technology

    Food Analysis

    Administration

    Locations and Departments

  • 7/30/2019 04 Migrationtesting_Pitzl

    4/29

    www.ofi.at

    4

    Main Focus:

    Certification / Consulting in case of Damage Claims

    Testing & Quality Assurance

    Assessment according to the European Food Legislation / LMSVG

    Clients R&D-Projects

    Branch-oriented R&D-Projects

    Branch-oriented Training and Education

    ...

    Packaging(incl. food commodities)

  • 7/30/2019 04 Migrationtesting_Pitzl

    5/29

    www.ofi.at

    5

    Migration

    Scalping

    Migration

    ActivePackaging

    H2O

    Gas

    FlavourProduct

    Light

    Mech.

    Stress Hygiene

  • 7/30/2019 04 Migrationtesting_Pitzl

    6/29

    www.ofi.at

    6

    Potential Migrants

    Glas

    - Silicates, heavy metals

    Plastics

    - Plasticizers, monomers, antistatics ...

    Paper

    - Additives and fillers (chalk etc.)

    Metal

    - Aluminium, tin for acid contents

  • 7/30/2019 04 Migrationtesting_Pitzl

    7/29

    www.ofi.at

    7

    Migration

    How can be prevented that an illegitimate amount of

    contents of the packaging migrates into the

    product?

    Choosing the right packaging!

    Ensured by migration testing

    - Compliance with overall migration limit (OML)

    - Specific migration limits (SML)

    - Maximum legitimate residual content of the substancein the finished food contact material (QMA)

    !!! Consideration of actual applied conditions

    (time and temperature combinations)

  • 7/30/2019 04 Migrationtesting_Pitzl

    8/29

    www.ofi.at

    8

    Migration Testing

    Test conditions according to 2002/72/EC

    Basics for migration tests

    82/711/EEC Basic rules for testing migration

    93/8/EEC 1st amendment

    97/48/EEC

    2nd amendment List ofsimulants: 85/572/EEC

    2007/19/EEC 1st amendment

    VC in PVC: 78/142/EEC (residual content and transfer to foodstuff)VC-analysis: 80/766/EEC, 81/432/EEC

    Certain epoxy derivatives: REG (EC) Nr. 1895 / 2005

    Plasticizers in gaskets in lids: REG (EC) Nr. 372/2007

  • 7/30/2019 04 Migrationtesting_Pitzl

    9/29

    www.ofi.at

    9

    CEN TC 194

    Utensils in Contact with Food

    SC 1: General chemical methods

    Standard EN 1186:

    Test methods for overall migration

    Standard EN or CEN/TS 13130:Standard methods for the specific migration (SML/QM)

    currently, 28 parts are published within this standard

    European Standardsconcerning plastics in contact with foodstuff

  • 7/30/2019 04 Migrationtesting_Pitzl

    10/29

    www.ofi.at

    10

    Aqueous foods pH > 4,5

    Distilled water (A)

    Acidic foods pH 4,5

    3 % (w/v) Acetic acid (B)

    Alcoholic foods:

    10 % (v/v) Ethanol (C)

    milk / milk products:

    50 % (v/v) Ethanol

    Fatty foods:Rectified olive oil (D)

    Dry foods:

    none

    Simulants

    if ethanol content > 10 %:adaptation to the actual content!

  • 7/30/2019 04 Migrationtesting_Pitzl

    11/29

    www.ofi.at

    11

    Selection of the right Simulant

    List of simulants:

    Regulation 85/572/EECExample:

  • 7/30/2019 04 Migrationtesting_Pitzl

    12/29

    www.ofi.at

    12

    Migration Testing:

    Unknown contact time, application

    for ambient temperature or lower temperatures:

    10 d / 40 C(all simulants)

    Unknown contact time & unknown application temperature:

    4 h / 100 C bzw. Reflux(simulant A, B, C)2 h / 175 C(simulant D)

    Hot filling (< 15 min at 70-100 C):2 h / 70 C(all simulants)

    Standardized Testing Conditions according to

    European Regulations / Austrian Plastics Regulation

    Overall migration

    bottom sediments

  • 7/30/2019 04 Migrationtesting_Pitzl

    13/29

    www.ofi.at

    13

    Migration Testing

    Substitute test for fatty foods

    If the use of fatty food simulants is not feasible for

    technical reasons

    Substitution: defined test media and conditions,

    corresponding to the simulant D

    Iso-Octan

    Ethanol (95 %)

    Modified Polyphenylenoxid (Tenax)

  • 7/30/2019 04 Migrationtesting_Pitzl

    14/29

    www.ofi.at

    14

    Migration Testing

    Consideration of the practical usage conditions of the packaging (e. g. for whichfoodstuff applied?)

    Clarification of the usage conditions

    Selection of the simulant and test conditions

    (contact time and temperature)

    Is overall migration limit complied (OML)?

    Compliance with thresholds of the specific migration (SML)

    residual content in the commidity (QM)?

    Migration Tests for finished commodities

  • 7/30/2019 04 Migrationtesting_Pitzl

    15/29

    www.ofi.at

    15

    Structure of the actual EU-Laws

    For materials and articles in contact with foodstuff

    Main-REG (EC)

    Nr. 1935/2004

    Specific Directives

    BADGE, BFDGE, NOGE

    VO (EG) Nr. 1895/2005

    Vinyl chloride

    78/142/EEC

    Reg. Cellulose

    2007/42/EC

    Analyses of VC

    81/432/EEC

    Analysis ofVC-content80/766/EEC

    Ceramik84/500/EEC

    amanded2005/31/EC

    Plastic

    2002/72/EC

    amandedVO Nr. 975/2009

    Rules Migration

    82/711/EECamended 97/48/EEC

    List of Simulants

    85/572/EECamended 2007/19/EC

    GMP-REG (EC)

    Nr. 2023/2006

    Recycl.-REG (EC)

    Nr. 282/2008

    A&I-REG (EC)

    Nr. 450/2009

  • 7/30/2019 04 Migrationtesting_Pitzl

    16/29

    www.ofi.at

    16

    EU-Substances List / Synoptic Document

    EU-Substances List

    - Based on: 2002/72/EG incl. supplements

    - Containing an authorised positive list of monomers

    and an incomplete list of additives

    For certain substances thresholds are available

    which are expressed

    - either as maximum quantity in material or article (QM)

    - or as specific migration limit in food (SML).

  • 7/30/2019 04 Migrationtesting_Pitzl

    17/29

    www.ofi.at

    17

    SML / QM

    Test Methods: migration test medium + GC, HPLC

    Positive List (excerpt):

  • 7/30/2019 04 Migrationtesting_Pitzl

    18/29

    www.ofi.at

    18

    SML Save Testing Costs

    Special Cases:

    100% migration < SML

    Calculation model

  • 7/30/2019 04 Migrationtesting_Pitzl

    19/29

    www.ofi.at

    19

    Gas Chromatography

  • 7/30/2019 04 Migrationtesting_Pitzl

    20/29

    www.ofi.at

    20

    Chromatographic Separation

    Separation of substances mixture due to different retention times ofeach single analyte during the transport through thechromatographic bed

  • 7/30/2019 04 Migrationtesting_Pitzl

    21/29

    www.ofi.at

    21

    Definitions

    DECISION LIMIT: Threshold for the presence of an analyte

    (yes/no). If a sample possessed the exact content of the dicisionlimit, the analyte wouldnt be detected in 50 % of the measurements

    despite the presence of the analyte (false negative).

    DETECTION LIMIT: minimal concentration of an analyte, which isdetected with a high likeliness (e. g. 95 %). The detection limit is

    usually twice the amount of the decision limit.

    DETERMINATION LIMIT: lowest concentration of an analyte,which can be quantitatively detected with a determined accuracy.Quantitative analyse results are only declared above the

    determination limit. The determination limit equals approximately thetriple amount of the decision limit.

  • 7/30/2019 04 Migrationtesting_Pitzl

    22/29

    www.ofi.at

    22

    Thermodesorber:

    Gas Chromatography

  • 7/30/2019 04 Migrationtesting_Pitzl

    23/29

    www.ofi.at

    23

    Screening Methods

    Migration or directly in food

    Which peaks are explainable, which are not?

    Criticism: Analysis method? Comparability? Undetected

    substances?

    3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.000

    10000

    20000

    30000

    40000

    50000

    60000

    70000

    80000

    90000

    100000

    110000

    120000

    130000

    140000

    Time-->

    Abundance

    TIC: HUND002.D

    3.26

    3.51

    3.57

    3.77

    4.18

    4.74

    4.87

    5.06

    5.15

    5.966.21

    7.19

    7.29

    8.90

    9.78

    11.15

    12.74

  • 7/30/2019 04 Migrationtesting_Pitzl

    24/29

    www.ofi.at

    24

    Special Regulation Lid Gaskets

    Regulation 372/2007/EG

    laying down transitional migration limits for

    plasticizers in gaskets in lids intended to come into

    contact with food

    SML for: fatty food: 300mg/kg*

    all others: 60 mg/kg*

    baby / infant food: 30 mg/kg*(restriction for ESBO)

    * of food or food simulant

  • 7/30/2019 04 Migrationtesting_Pitzl

    25/29

    www.ofi.at

    25

    Example - ITX

    Isopropylthioxanthone (ITX)

    Photointitiator in UV-curing printing inks

    Application: outside of food packaging (compound for

    milk, cacao, juice)

    Problems:

    - Set offeffect

    - Migration

    !!! Threshold 0,05 mg/kg ITX in food

  • 7/30/2019 04 Migrationtesting_Pitzl

    26/29

    www.ofi.at

    26

    How to test Set off?

    IVLV cluster commodities

    Working group of German-speaking testing laboratorieseurofins, Fresenius, GALAB, GfU, innoform, ISEGA, MUVA, Nehring, of i, SQTS

    Agreement on common test conditions:

    Time / Temperature- at customer- at laboratory: a) guideline value 10 days at 40 C

    b) alternatively according to actual application

    Pressure- three-dimensional - pile (according to customer)

    - flat/foil a) rollb) pile- full-surface contact- flexible - 1kg/dm

    Sample Name / Storage

  • 7/30/2019 04 Migrationtesting_Pitzl

    27/29

    www.ofi.at

    27

    PIMwhats next?

    New simulants

    e. g. Tenax:

  • 7/30/2019 04 Migrationtesting_Pitzl

    28/29

    www.ofi.at

    28

    PIMwhats next?

    Priority:1. Specific migration

    2. Overall migration

    Overall migration:

    Test conditions OM1-9 Regulations forrepeated contacts

    Multi-layermaterials and articles

    Test at 10 d 60 C for storage times > 30 d

    Substitute simulants(scientific evidence)

  • 7/30/2019 04 Migrationtesting_Pitzl

    29/29

    www.ofi.at

    29

    sterreichisches Forschungsinstitutfr Chemie und Technik (ofi)

    Brehmstrae 14A1110 Vienna

    +43-(0)1-798 16 01 ext.

    +43-(0)1-798 16 01 - 480

    DI Michael Pitzl(ext. 597, E-Mail: [email protected])

    Contacts