3
Kit completi TEST& MEASUREMENTS 216x series Working Reference Secondary Standard Thermocouples       B      u       l       l      e       t       i      n      n  .         0        1           0       4  .        2       E Eurotron - One of the leaders in high technology equipments: high accuracy calibrators - non-contact IR thermometers - portable flue gas analyzers. ! ! ! ! ! ! Thermocouple type S, and K.  Rugged, accurate and reliable working standard  Exc ellen t stabil ity and repe atabilit y  High purity homogenous wires and insulating material Temperature range up to 1400°C  Metal base thermocouples available on request General The International Temperature Scale (ITS 90) sets the standard platinum resistance thermometers as the interpol at ion instr ument up to +961 .7C (free zing poin t of silve r). Primary Standard Thermometers should be used for high accuracy measurements and calibration. However for routine calibration by a comparative method, a type S Standard Thermocouple can be used as a Secondary o r Reference Sta ndard. The Eurotron Working or Reference Standard thermocouple cat.2160 meets the repeatability and stability requirements of most industrial metrology laboratories. This thermocouple can be used to make continuou s accurate mea surements in th e range up to 140 0°C and for inte rmitt ent use up to 1450°C with inert atmosphere. The thermocouple can be easily disassembled for maintenance or calibration. The measuring  junction can be easily removed for calibration or to remake the junction. Base metal working Standard thermocouples are also available. Report of Calibration The measure ment uncertain ties of the data shown in the Eurotron Calibration Report are: from 0°C to 600°C: ±0.2 °C from 600°C to 1100°C: ±2 °C On request a thermometer can be calibrated and supplied with a SIT Report of Calibration on five points. The calibration will be made using a comparative method in the appropriate temperature range.  A computer compiled emf-temperature table can be generated using the constants provided together with the Report of Calibration. Standard reso lution is 1°C in the range from 0°C to +1100°C. The measurement uncertain ties of the data shown in the SIT Report are: from 0°C to 600°C: ±0.2 °C from 600°C to 1100°C: ±1 °C ! ! ! ! eurotron

01-04.2 E WKS 216X

Embed Size (px)

Citation preview

Page 1: 01-04.2 E WKS 216X

8/3/2019 01-04.2 E WKS 216X

http://slidepdf.com/reader/full/01-042-e-wks-216x 1/2

Page 2: 01-04.2 E WKS 216X

8/3/2019 01-04.2 E WKS 216X

http://slidepdf.com/reader/full/01-042-e-wks-216x 2/2