Upload
khangminh22
View
1
Download
0
Embed Size (px)
Citation preview
2 di 16 II_T4000_01_eng
Installation Instructions
Touch Manager
Company
Founded in 1983 with the aim of providing a complete range of professional products, Tecnosicurezza is now a consolidated reality in the field of locks and security systems for safes. The experience gained in over 35 years of activity in the security sector has allowed the designing and manufacturing of high technology and reliability systems, which continue to receive the approval of an increasingly demanding clientele. TECNOSICUREZZA is present directly all over the world through its own branches and with an extensive distribution network. TECNOSICUREZZA is aimed at national and international customers of primary importance, such as banks, safe manufacturers, cash in transit companies, mass market retailers and post offices. Today TECNOSICUREZZA is a leading company focused on the customers’ needs and constantly in step with technology.
II_T4000_01_eng 3 di 16
Installation Instructions
Touch Manager Table of contents
COMPANY 2
TABLE OF CONTENTS 3
IMPORTANT NOTES! 4
DALLAS READER DIMENSIONS 5
ROTOBOLT LOCK DIMENSIONS 6
STRAIGHTBOLT LOCK DIMENSIONS 6
SPRINGBOLT LOCK DIMENSIONS 6
MOTORLOCK LOCK DIMENSIONS 7
MOTOR SPRINGBOLT DIMENSIONS 7
DALLAS READER INSTALLATION INSTRUCTIONS 8
ROTOBOLT LOCK INSTALLATION INSTRUCTIONS 9
STRAIGHTBOLT AND SPRINGBOLT LOCKS INSTALLATION INSTRUCTION 9
MOTORLOCK AND MOTOR SPRINGBOLT LOCKS INSTALLATION INSTRUCTIONS 10
FUNCTIONAL TEST 12
CONTACTS 16
4 di 16 II_T4000_01_eng
Installation Instructions
Touch Manager
Important notes!
Before installing this product, please carefully read the installation and operating
instructions.
Locks can be installed on all traditional safes.
Lock has to be mounted on secure storage metal (preferred steel) units only.
Locks must be protected against external attacks, for this reason it is recommended to
install them on the door away from any through holes.
If locks are not properly protected by systems belonging to the safe (manganese plates,
glass plate, relocking, etc.) only StraightBolt (T4000/D) and MotorLock (T4001/M and
T4001/MP) locks can be mounted behind the passage hole for the connection cable or
the spindle.
Any electronic part must be properly protected and not easily accessible even when the
door is open.
Locks have been developed to work correctly in a temperature range from -5 ° C to + 50
° C and in an environment with non-condensing humidity between 25% and 90%.
The mounting dimensions are standard (magic module).
Locks are supplied with metric (M6) mounting screws. Upon request, Imperial 1/4-20 UNC
format mounting screws are available.
The type of material and the length of the screws must, in any case, be selected so as to
guarantee long life and reliability.
Tighten the screws so that the lock is firmly fixed to the mounting surface
(recommended torque between 2.5 and 5.5 Nm).
The mounting surface must be perfectly flat.
In order to prevent loosening of the screws it is recommended the use of LOCTITE®
threadlocker and/or specific washers positioned under the head of the fixing screw.
The diameter of the passage hole for the connection cable or the spindle must not
exceed 11 mm.
The hole must be completely clear of drill dust and sharp edges.
Do not lubricate lock.
II_T4000_01_eng 5 di 16
Installation Instructions
Touch Manager
In the locked position, the distance between the bolt and the boltwork part that is
moving the lock bolt must comply with the following specifications for each type of lock.
Any component to be fixed to the lock bolt must be previously approved by
Tecnosicurezza before installation. In any case, the maximum load must not exceed 2.5 N
for T4000/M model, 4N for T4001/M and 30N for T4001/MP.
Secure the cables away from moving parts by using cable ties and cable ties bases.
If placed in normal domestic or office environments, the locks do not require particular
maintenance; in any case, after 10,000 opening/locking cycles, it is recommended to run
a test that verifies the correct and complete operation of the product.
Do not use cleaning agents with chemical, abrasive or alcohol-containing additives to
clean the components. Use only a damp cloth.
Do not spray liquid directly onto the components.
Dallas reader dimensions
Emergency external battery contact
6 di 16 II_T4000_01_eng
Installation Instructions
Touch Manager
RotoBolt lock dimensions T4000
StraightBolt lock dimensions T4000/D
SpringBolt lock dimensions T4000/S
II_T4000_01_eng 7 di 16
Installation Instructions
Touch Manager MotorLock lock dimensions T4000/M
T4001/M
Motor SpringBolt dimensions T4000/M/S
8 di 16 II_T4000_01_eng
Installation Instructions
Touch Manager
Dallas reader installation instructions
The Dallas reader is provided with two M4 countersunk screws (Imperial screws 8-32 UNC are available on request) and two M3 screws. Prepare the mounting holes on the safe door. Remove backplate from the Dallas reader and affix it on the safe door using provided M4 screws.
Insert the cable inside the spindle hole, hook Dallas reader to the backplate, rotate the emergency battery protection counterclockwise down and affix the reader to the backplate with provided M3 screws.
Insert the Dallas reader cable into the lock connector “1” or “ENT” and the power supply interface in the “2” or “BAT” connector.
T4000 models
T4000/M models
T4001/M model
II_T4000_01_eng 9 di 16
Installation Instructions
Touch Manager RotoBolt lock installation instructions
The RotoBolt lock is a swingbolt lock in which the blocking mechansim is carried out by a motor. By placing an opening Dallas key, it removes the blocking mechanism and the boltwork can be moved into open position by pushing the bolt inside the lock case. The bolt automatically secures when the safe handle, or the safe door mechanism, is brought to the locked position. If the RotoBolt lock is used in conjunction with other locks, the safe door mechanism must ensure the closure of the RotoBolt before the other locks. The lock can be mounted in all four mounting directions (RH, LH, VU, VD). Furthermore, by flipping the lock, both locking directions can be realized (RH/LH).
The maximum load applicable to the bolt must not exceed 1KN. Contact Tecnosicurezza in case of heavier loads. It is possible to connect a relocker to the lock cover through the appropriate holes.
StraightBolt and SpringBolt locks installation instruction StraightBolt and SpringBolt locks are locks with a dead bolt and a spring bolt, in which the blocking mechanism is carried out by a motor. By placing an opening Dallas key, it removes the blocking mechanism and the boltwork can be moved into open position by turning the spindle inserted in the lock. The spindle can be connected to a knob or to a handle. When the spindle is brought to the locked position, the bolt extends ensuring the lock is locked. The locks can be mounted in all four mounting directions (RH, LH, VU, VD). Furthermore, by flipping the lock, both locking directions can be realized (RH/LH – not for T4000/S SpringBolt lock version).
In the locked position the distance between the RotoBolt bolt and the RotobBolt part that is moving the lock bolt should be approximately 1 mm.
The bolt must be able to move freely without force
being applied to it.
Affix the relocker plate with M4 self tapping flat head screws. Length must be 6mm + plate thickness.
(i.e. 6mm + 2mm plate = 8mm screw)
10 di 16 II_T4000_01_eng
Installation Instructions
Touch Manager
In the locked position, there should be approximately 1 mm clearance between the lock bolt and the cavity in the blocking bar of the boltwork. The bolt must be able to move freely without force being applied to it.
In open position, there should be minimum 3mm and maximum 5 mm clearance between the lock bolt and
the blocking bar of the boltwork.
The maximum load applicable to the bolt must not exceed 1KN. Contact Tecnosicurezza in case of heavier loads. The spring-latch version (SpringBolt) is designed to ensure self locking when the door closes.
The spindle must be inserted between 7 mm and 12 mm inside the lock. It is possible to connect a relocker to the lock cover through the appropriate holes.
MotorLock and Motor SpringBolt locks installation instructions MotorLock and Motor SpringBolt locks are locks with a motor driven dead bolt and a motor driven spring bolt, in which the blocking mechanism is carried out by a motor. By placing an opening Dallas key the motor retracts the bolt which remains in the open position for a specific time (by default it is programmed for 8 seconds) then automatically returns to the locked position. All lock versions can be mounted in all four mounting directions (RH, LH, VU, VD).
The distance between the SpringBolt lock and the locking edge must be between a minimum of 3 mm and a maximum of 8 mm.
When locked, there must be a 0.5mm gap between lock bolt and locking
surface.
Affix the relocker plate with M4 self tapping flat head screws. Length must be 6mm + plate thickness.
(i.e. 6mm + 2mm plate = 8mm screw)
II_T4000_01_eng 11 di 16
Installation Instructions
Touch Manager Furthermore, by flipping the lock, both locking directions can be realized (RH/LH – not for T4000/M/S Motor SpringBolt lock version). The mounting dimensions are standard (magic module). Locks are supplied with metric (M6) mounting screws. Upon request, Imperial 1/4-20 UNC format mounting screws are available.
T4000/M
T4001/M and T4001/MP
T4000/M
T4001/M and T4001/MP
The latch version (Motor LatchBolt) is specially designed to ensure self locking when the door closes. T4000/M/S
T4001/M/S
When locked, there must be a 0.5mm gap between lock bolt and locking surface.
T4000/M/S
T4001/M/S
In the locked position, there should be approximately 1 mm clearance between the lock bolt and the cavity in the blocking bar of the boltwork. The bolt must be able to move freely without applying any force on it.
In open position, there should be a minimum of 3 mm and maximum of 5 mm clearance between the lock bolt and the blocking bar of the boltwork.
In depending of the motor lock type, the distance between the SpringBolt lock and the locking edge must be between a minimum of 3 mm and a maximum of 8 mm or between minimum of 6 mm and a maximum of 10 mm.
12 di 16 II_T4000_01_eng
Installation Instructions
Touch Manager
The maximum load applicable to the bolt must not exceed the limit values specified in the table below. Contact Tecnosicurezza in case of heavier loads.
Lock reference Lock version Maximum force to apply on the bolt
Maximum load pulled up by the bolt
T4001/M/xx Pull and spring version – Cass B 1KN (100 Kg) 4N (400 gr)
T4001/MP/xx Pull and push version – Class B 1KN (100 Kg) 30N (3Kg)
T4001/M/S/xx Latch version 1KN (100 Kg) -
On the T4001/M lock (and the relative versions above) it’s possible to connect a relocker to the lock cover through the appropriate holes.
Functional test To be carried out with the door open.
T4000, T4000/D, T4000/S Provide power to the lock. Place an opening Dallas key on the reader. The Dallas reader emits a double beep. With RotoBolt (T4000) lock turn the safe door handle to the OPEN position within 4 seconds. With StraightBolt (T4000/D) and SpringBolt (T4000/S) locks, rotate the knob within 4 seconds to move the lock bolt to the OPEN position and turn the safe door handle to the open position. For all types of locks the bolt must be able to move freely. Turn boltwork handle or knob towards LOCKED position. The lock bolt must fully extend and secure. Make sure there is an air space on all sides of the lock bolt when the safe’s boltwork is fully thrown into LOCKED position.
T4000/M models and T4001/M models Provide power to the lock. Place an opening Dallas key on the reader. The Dallas reader emits a double beep and the lock automatically opens. Turn boltwork handle towards OPEN position. Bolt must move freely. After the opening time (8sec standard) the lock automatically closes. With MotorLock locks with manual reclosure, place again an opening Dallas key on the reader. Turn boltwork handle towards LOCKED position. The lock bolt must fully extend and secure. Make sure there is an air space on all sides of the lock bolt when the safe’s boltwork is fully thrown into LOCKED position.
Repeat functional test several times before locking the safe door. Failure to follow these installation instructions or opening the lock by personnel not authorized by Tecnosicurezza will void the warranty.
Fix the relocker plate with M4 self tapping flat head screws. Length must be 6mm + plate thickness.
(i.e. 6mm + 2mm plate = 8mm screw)
Correct disposal of this product:
(Waste Electrical & Electronic Equipment)
Applicable in the European Union and other European countries with separate collection systems.
This marking displayed on the product or its literature indicates that it should not be disposed with other wastes at the end of its
working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other
types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Contacts
GLOBAL HEADQUARTERS USA HEADQUARTERS SPAIN HEADQUARTERS
Tecnosicurezza SpA Tecnosicurezza Inc. Tecnosicurezza Sa
Via Cesare Battisti. 276 50, Thomas Lane C/Menor, 4 - Nave 10 37057 San Giovanni Lupatoto
Verona Versailles, KY 40383 Pol. Ind La Mina 28770 Colmenar Viejo
Tel.+39 045 826 64 70 Tel.+1 859 490 89 30 Tel.+34 91 804 33 91
Fax. +39 045 826 64 69 Fax.+34 91 804 32 63