32
*** DGS THE O[PAATUENT OF llER\llCES GOVERNMENT OF THE DISTRICT OF COLUMBIA DEPARTMENT OF GENERAL SERVICES * * * CONSTRUCTION SERVICES FOR EAST POTOMAC POOL Solicitation No: DCAM-17-CS-0083 Addendum No. 6 Issued: June 2. 2017 * * * Wf; ARE; WASHINGTON This Addendum No. 6 is issued and hereby published on the DGS website on June 2, 2017. Except as modified hereby, the Invitation for Bid ("IFB") remains unmodified. Item #1 A. 7 Attachments Delete: Attachment B - Revised Form of Offer Letter Insert: Attachment B - Revised Form of Offer Letter (Exhibit 1) Item #2 Responses to Questions about the Solicitation (Exhibit 2) Item #3 Spec 087100 Door Finish Hardware (Exhibit 3) Item #4 Drawing A-601 Revised (Exhibit 4) Elduisefripp Date: Lead Contract Specialist - End of Addendum No. 6 -

Construction Services for East Potomac Pool - DC DGS

Embed Size (px)

Citation preview

*** DGS THE O[PAATUENT OF QEMl.l\~L llER\llCES

GOVERNMENT OF THE DISTRICT OF COLUMBIA DEPARTMENT OF GENERAL SERVICES

* * *

CONSTRUCTION SERVICES FOR EAST POTOMAC POOL Solicitation No: DCAM-17-CS-0083

Addendum No. 6 Issued: June 2. 2017

* * * Wf; ARE; WASHINGTON

This Addendum No. 6 is issued and hereby published on the DGS website on June 2, 2017. Except as modified hereby, the Invitation for Bid ("IFB") remains unmodified.

Item #1 A. 7 Attachments

Delete: Attachment B - Revised Form of Offer Letter Insert: Attachment B - Revised Form of Offer Letter (Exhibit 1)

Item #2 Responses to Questions about the Solicitation (Exhibit 2)

Item #3 Spec 087100 Door Finish Hardware (Exhibit 3)

Item #4 Drawing A-601 Revised (Exhibit 4)

By: i~ Elduisefripp

Date:

Lead Contract Specialist

- End of Addendum No. 6 -

DCAM-17-CS-0083 Attachment B – Form of Offer Letter and Bid Form

[Contractor’s Letterhead]

[Insert Date] Ms. Brenda Allen Chief Contracting Officer, C&P District of Columbia Department of General Services 2000 14th Street, NW, 8th Floor Washington, DC 20009 Reference: Invitation for Bid DCAM-17-CS-0083

Construction Services for East Potomac Pool

Dear Ms. Allen: On behalf of [INSERT NAME OF BIDDER] (the “Bidder”), I am pleased to submit this bid in response to the Department of General Services’ (the “Department” or “DGS”) Invitation for Bid (the “IFB”) for the Construction Services at East Potomac Pool. The Bidder has reviewed the IFB and the attachments thereto, any addenda thereto, and the proposed Form of Contract (collectively, the “Bid Documents” or “Contract Documents”) and has conducted such due diligence and analysis as the Bidder, in its sole judgment, has deemed necessary in order to submit its bid in response to the IFB. The Bidder’s bid and the Lump Sum Price are based on the Bid Documents as issued and assume no material alteration of the terms of the Bid Documents. (Collectively, the bid and the Lump Sum Price are referred to as the “Bidder’s Bid”.) The Bidder’s Bid is as follows:

CLIN DESCRIPTION Lump Sum Price

001

Construction Services for East Potomac Pool as described in the Scope of Work (Section B) and Project Drawings and Specifications (Attachments A).

$__________________

Lump Sum Price for CLIN 001 $__________________

Allowance 1 Furniture $50,000.00 Allowance 2 Permits $100,000.00

Lump Sum Price w/ Allowances $__________________

LUMP SUM PRICE W/ ALLOWANCES IN WORDS for CLIN 001: _____________________________________________________________________________________

DCAM-17-CS-0083 Attachment B – Form of Offer Letter and Bid Form

When requested by the Contracting Officer, Offeror's shall add to the lump sum price CLIN 001 the price for the add alternates below:

ADD ALT DESCRIPTION

3 Provide all labor and materials for a complete installation of Shading Structures at Team Areas, including bleachers, foundation system structure and connection/fastening hardware and awning.

$________

ADD ALT DESCRIPTION

4 Provide all labor and materials for a complete installation of the 3m and 5m platforms.

$________

ADD ALT DESCRIPTION

5 Provide all labor and materials for a complete installation of the 3m springboards. $________

ADD ALT DESCRIPTION

6 Provide all labor and materials for a complete installation of the Scoreboard and foundation system.

$________

ADD ALT DESCRIPTION

7 Provide all labor and materials for a complete installation of the sparger system. $________

The Bidder shall submit a completed Price Breakdown Form (Exhibit 1), providing the price for each Division Component. The sum of all the prices for each Division Component must equal the Lump Sum Price for CLIN 001. In the event of discrepancies between or among the Lump Sum Price and the Price Breakdown of each Division Component, the Lump Sum Price shall control. The Bidder’s Bid is based on and subject to the following conditions: 1. The Bidder agrees to hold its bid open for a period of at least one hundred twenty (120) days after the IFB closing date. 2. Assuming the Bidder is selected by the Department and subject only to the changes requested in paragraph 5, the Bidder agrees to enter into a contract with the Department on the

DCAM-17-CS-0083 Attachment B – Form of Offer Letter and Bid Form

terms and conditions described in the Bid Documents within ten (10) days of the notice of the award. 3. Both the Bidder and the undersigned represent and warrant that the undersigned has the full legal authority to submit this bid form and bind the Bidder to the terms of the Bidder’s bid. The Bidder further represents and warrants that no further action or approval must be obtained by the Bidder in order to authorize the terms of the Bidder’s bid. 4. The Bidder and its principal team members hereby represent and warrant that they have not: (i) colluded with any other group or person that is submitting a bid in response to the IFB in order to fix or set prices; (ii) acted in such a manner so as to discourage any other group or person from submitting a bid in response to the IFB; or (iii) otherwise engaged in conduct that would violate applicable anti-trust law. 5. The Bidder hereby certifies that neither it nor any of its team members have entered into any agreement (written or oral) that would prohibit any contractor, subcontractor or subconsultant that is certified by the District of Columbia Office of Department of Small and Local Business Enterprises as a Local, Small, Resident Owned or Disadvantaged Business Enterprise (collectively, “LSDBE Certified Companies”) from participating in the work if another company is awarded the contract. 6. This Form of Offer Letter and Bid Form are being submitted on behalf of [INSERT FULL LEGAL NAME, TYPE OF ORGANIZATION, AND STATE OF FORMATION FOR THE BIDDER]. Sincerely, Company: _________________________ Name: ___________________________ Title: ___________________________ Date: ___________________________ Signature: ________________________

DCAM-17-CS-0083 Attachment B – Form of Offer Letter and Bid Form

Exhibit 1 - Price Breakdown Form

CLIN 001 – Construction Services for East Potomac Pool

DIVISION NO. DESCRIPTION DIVISION COST

Div. 01 General Requirements

Div. 02 Existing Conditions (incl. abatement/demo)

Div. 03 Concrete

Div. 04 Masonry

Div. 05 Metals

Div. 06 Woods and Plastics

Div. 07 Thermal and Moisture Protection

Div. 08 Openings

Div. 09 Finishes

Div. 10 Specialties

Div. 11 Equipment

Div. 12 Furnishings

Div. 13 Special Construction

Div. 14 Conveying Systems

Div. 21 Fire Suppressions

Div. 22 Plumbing

Div. 23 Heating, Ventilation and Air Conditioning

Div. 26 Electrical

Div. 27 Communications

Div. 28 Electronic Safety and Security

Div. 31 Earthwork

Div. 32 Exterior Improvements

Div. 33 Utilities

Lump Sum Price CLIN 001: $_____ __________________

Allowance 1 Furniture $50,000.00

DCAM-17-CS-0083 Attachment B – Form of Offer Letter and Bid Form

Allowance 2 Permits $100,000.00

Lump Sum Price w/ Allowances $_____ __________________

DCAM-17-CS-0083

Construction Services for East Potomac Pool

Questions

No. Reference Question Response

78

Note N5C on drawing A-101 calls for metal ladders in the surge

chamber while detail 1 on drawing CP-7 shows FRP ladders.  Please

clarify which type of ladder to provide.

Use FRP.

79

Detail A2 on drawing A-312 calls for aluminum ladder at the

backwash tank while detail 9 on drawing MR.5 shows FRP ladder. 

Please clarify which type of ladder to provide.

Use FRP.

80

Detail 9 on drawing MR.5 indicates guardrail at the backwash tank

while the floorplans do not.  Please verify if guardrails are required

at the backwash tank.

They are required.

81

Demolition note 12 on drawing C-200 calls for us to “demolish and

infill vault” located on the other side on the chain link fence. Do you

have any information on the size or use of the vault?

It apears to be an abandoned vault, purpose unknown. Based on

observation approximately 3'x3 foot concrete vault.

82

Note 9 on drawing E-003 calls for new ductbank to terminate 1’

outside of property line, but the drawings do not indicate the location

of the property line.  Please clarify the quantity of ductbank required.

JVP is awaiting clarification from Pepco, since the entire site

belongs to the National Park Service.

83We did not find section 087100 Door Hardware even though it is

listed in the table of contents.  Please provide missing spec section.See Addendum 6, Item #3

84

The hardware sets listed on drawing A602 all use Allegion products. 

Please verify if other manufacturers may be used (ASSA Abloy,

Corbin Russwin, Yale, Stanley, Best, Precision).

Yes, other equivalent products can be submitted for approval.

85

Specifications

Section

102601

Manufactured Wall and Corner Guards: Wall and corner guards are

not specified in drawings. Please confirm locations.

There are no corner guards in this project. Use bullnosed CMU

at all corner locations.

86

Specifications

Section

122113

Horizontal Louver Blinds: Louver Blinds location and models are

not specified. Please confirm locations.

See question 63 for locations. Use Hunter Douglas Décor as the

basis-of-design.

87

Specifications

Section

321400

Unit Paving Part 2.01 B states color TBD. Please specify color.

http://www.tecturadesigns.com/products/pavers/expressions

Expressions Series Pavers: Color XP-50

Blasted Glass Pavers: Color Color BG-104

88 C6.L-901

Unit Paving Part 2.01 B states Expressions is to be 75% of the area

and Blasted Glass is to be 25%. Do these quantities match the sketch

made in C6/L-901.

Note that detail C6.L-901 has been deleted from the updated

sheet L-901 dated 5/16/2017. That said, same proportion of

Expressions and Blasted Glass pavers are to be used in updated

paving sketch as shown on the updated L-101 dated 5/16/2017.

Area shown to be Tectura unit pavers is 1088 sq. ft.

89 A6.L-901Fountain: Architect to provide cost and scope limitations. Please

provide details on if/when this will happen.

This detail and fountain/art piece have been deleted from the

updated sheet L-901 and the landscape addendum drawings

dated 5/16/2017.

90 Please provide us with the height for light poles (Fixture Type W1) W1 Pole is to be 10 feet tall.

91

As we discussed, can you clarify if the Saftety Center, Concessions,

Meeting Room, Offices, etc that are not showing sprinkler coverage

on the Fire Sprinkler plan F101 is accurate?  

F101 shows sprinkler coverage accurately. Sprinkler protection

is required for locker rooms and family room changing rooms

per IBC 903.2.1.5. The section requires sprinkler protection for

A-5 areas exceeding 1,000 sq.ft. Also, sprinkler protection is

required for the basement per IBC 903.2.11.1. The basement

area is exceeding 1,500 sq.ft and has a limited opening.

92Sparger systems is not specified anywhere in the bid document.

How can we price?See response to question 35.

93Is the pool approved by the health department yet? Who’s

responsible for paying the pool permit?

No it has not been approved. The existing pool is to be

removed. The new pool being installed in its place will have to

be approved by DOH. Hughes Group is processing the permit.

94

Page 7 of 62 of the Solicitation indicates hazardous material

remediation is part of the scope. Addendum 2 gave numerous

hazmat reports from 2015 to 2016, with the latest report from ECS

dated 6/2/2016 states that the hazardous material remediation is

already completed by Diversified Environmental, Inc. Are there any

remaining hazmat materials in this scope?

Refer to this report in detail. Only certain areas in the pump

room and basement storage area were remediated.

95 102

What type of 8" CMU will the interior walls be constructed with?

What type of CMU will the interior walls by sinks be constructed

with?

See spec section 042000 part 2.

96 103 & 105There is no partition type detail on A-011 for the 10" CMU shown in

detail D3/A501 for these rooms. Please provide a detail.Wall type is 'D sim.' CMU size varies.

97 107

The exterior Wall type is not specified for any side of this room.

Please specify. The wall base for this room is specified as V-2 in the

finish schedule (page A601), but this is a type of vinyl flooring.

Please confirm if we are to include VB-1 wall base in this room.

The exterior wall types are both A and B. The wall sections are

similar to A1/A-311 and A2/A-313. Base in this room is VB-1.

98 108

The exterior Wall type is not specified for any side of this room.

Please specify. The wall base for this room is specified as V-2 in the

finish schedule (page A601), but this is a type of vinyl flooring.

Please confirm if we are to include VB-1 wall base in this room.

The exterior wall types are both A and B. The wall sections are

similar to A1/A-311 and A2/A-313. Base in this room is VB-1.

99 111

For the south exterior wall of this room, there is a discrepancy

between detail A1/A313 (which shows exterior wall type A1) and

detail C1/A501 (which shows exterior wall type A). Detail C1/A501

is a detail that further defines detail A1/A313. Please specify which

exterior wall type to use for this room on the south side. No exterior

building type is specified for the west side of this room. Please

specify.

The exterior wall types are both A and B. The wall sections are

similar to A1/A-311.

100 Room 112No exterior building type is specified for the west side of this room.

Please specify.

The exterior wall types are both A and B. The wall sections are

similar to A1/A-311.

101 Room 113

The exterior building type for the north side of this room is shown as

“Exterior Wall Type 1”. Please specify which exterior wall type this

refers to (e.g. A, A1, B, B1, C, D).

The exterior wall types are both A and B. The wall sections are

similar to A1/A-311.

102 Room 113A

The exterior building type for the east side of this room is shown as

“Exterior Wall Type 1”. Please specify which exterior wall type this

refers to (e.g. A, A1, B, B1, C, D).

The exterior wall types are both A and B. The wall sections are

similar to A1/A-311.

103 Room 113B

The exterior building type for the east side of this room is shown as

“Exterior Wall Type 1”. Please specify which exterior wall type this

refers to (e.g. A, A1, B, B1, C, D).

The exterior wall types are both A and B. The wall sections are

similar to A1/A-311.

104East & West of

RM 102

Please provide a detail for the 4ea 42” high gates with guardrails to

be installed on the east and west sides of RM 102 (N32F on page

A101).

See response to question 62.

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-1

Part 1 - GENERAL 1.1 SUMMARY

A. Section Includes: 1. Door Hardware, including electric hardware. 2. Storefront and entrance door hardware. 3. Hold-open closers with fire-alarm interface. 4. Wall or floor-mounted electromagnetic hold-open devices. 5. Power supplies for electric hardware. 6. Low energy door operators plus sensors and actuators. 7. Remote button release hardware. 8. Cabinet locks. 9. Cylinders for doors fabricated with locking hardware. 10. Wiring and riser diagrams for electric hardware. 11. Key cabinets, key management software.

B. Related Sections:

1. Section 06200 - Finish Carpentry: Finish Hardware Installation. 2. Section 07900 - Joint Sealers – exterior thresholds. 3. Section 08100 - Metal Doors and Frames. 4. Section 08200 - Wood and Plastic Doors. 5. Section 08300 - Special Doors. 6. Section 08400 - Entrances and Storefronts. 7. Section 08900 - Glazed Curtain Walls. 8. Section 10650 - Operable Partitions. 9. Section 16722 - Fire/Life-Safety System. 10. Section 16724 - Security Access Systems. 11. Section 08115 - Metal Frame, Door and Impact Exit Device

Assemblies.

C. Specific Omissions: Hardware for the following is specified or indicated elsewhere.

1. Windows. 2. Cabinets, including open wall shelving and locks. 3. Signs, except where scheduled. 4. Toilet accessories, including grab bars. 5. Installation. 6. Rough hardware. 7. Folding partitions, except cylinders where detailed. 8. Sliding aluminum doors, except cylinders where detailed. 9. Access doors and panels, except cylinders where detailed. 10. Corner Guards. 11. Wrought Iron railing, gates and supports. 12. Brass rail and drink rail supports.

1.2 REFERENCES:

A. Use date of standard in effect as of Bid date.

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-2

B. American National Standards Institute – ANSI 156.18 – Materials and Finishes. C. ANSI A117.1 – Specifications for making buildings and facilities usable by physically

handicapped people. D. ADA – Americans with Disabilities Act of 1990 E. BHMA – Builders Hardware Manufacturers Association F. DHI – Door and Hardware Institute G. NFPA – National Fire Protection Association

1. NFPA 80 – Fire Doors and Windows 2. NFPA 101 – Life Safety Code 3. NFPA 105 – Smoke and Draft Control Door Assemblies 4. NFPA 252 – Fire Tests of Door Assemblies

H. UL – Underwriters Laboratories

1. UL10C – Fire Tests of Door Assemblies (Positive Pressure) 2. UL 305 – Panic Hardware

I. WHI – Warnock Hersey Incorporated J. SDI – Steel Door Institute K. WDI – Wood Door Institute L. AWI – Architectural Woodwork Institute M. NAAM – National Association of Architectural Metal Manufacturers

1.3 SUBMITTALS & SUBSTITUTIONS

A. SUBMITTALS: Submit six copies of schedule per Division 1. Organize vertically formatted schedule into “Hardware Sets” with index of doors and headings, indicating complete designations of every item required for each door or opening. Include following information:

1. Type, style, function, size, quantity and finish of hardware items.

Use BHMA Finish codes per ANSI A156.18. 2. Name, part number and manufacturer of each item. 3. Fastenings and other pertinent information. 4. Location of hardware set coordinated with floor plans and door schedule. 5. Explanation of abbreviations, symbols, and codes contained in schedule. 6. Mounting locations for hardware. 7. Door and frame sizes, materials and degrees of swing. 8. List of manufacturers used and their nearest representative with address and

phone number. 9. Catalog cuts. 10. Manufacturer’s technical data and installation instructions for electronic

hardware. 11. Date of jobsite visit.

B. Bid and submit manufacturer’s updated/improved item if scheduled item is discontinued.

C. Make substitution requests in accordance with Division 1. Include product data and

indicate benefit to the Project. Furnish operating samples on request.

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-3

1. Items listed with no substitute manufacturers have been requested by Owner to

meet existing standard.

D. Furnish as-built/as-installed schedule with closeout documents, including keying schedule, wiring/riser diagrams, manufacturers’ installation, adjustment and maintenance information, and supplier’s final inspection report.

1.4 QUALITY ASSURANCE:

A. Qualifications:

1. Hardware supplier: direct factory contract supplier who employs a Certified architectural hardware consultant (AHC), available at reasonable times during course Work for project hardware consultation to Owner, Architect and Contractor. (1) Responsible for detailing, scheduling and ordering of finish hardware.

B. Hardware: New, free of defects, blemishes and excessive play. Obtain each kind of

hardware (latch and locksets, exit devices, hinges and closers) from one manufacturer. C. Exit Doors: Operable from inside with single motion without the use of a key or special

knowledge or effort.

D. Fire-Rated Openings: In compliance with NFPA 80. Hardware UL10C/UBC-7-2 (positive pressure) compliant for given type/size opening and degree of label. Provide proper latching hardware, non-flaming door closers, approved-bearing hinges, plus resilient and required intumescent seals. Furnish openings complete.

1. Note: scheduled seals may exceed selected door manufacturer’s requirements.

See 2.6.E for clarification. E. Pre-Installation Meetings: Initiate and conduct with supplier, installer and related trades,

coordinate materials and techniques, and sequence complex hardware items and systems installation. Convene at least one week prior to commencement of related work.

1.5 DELIVERY, STORAGE AND HANDLING:

A. Delivery: coordinate delivery to appropriate locations (shop or field).

1. Permanent keys and cores: secured delivery direct to Owner’s representative.

B. Acceptance at Site: Items individually packaged in manufacturers’ original containers, complete with proper fasteners and related pieces. Clearly mark packages to indicate contents, locations in hardware schedule and door numbers.

C. Storage: Provide locked storage area for hardware, protect from moisture, sunlight, paint,

chemicals, etc…

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-4

1.6 PROJECT CONDITIONS:

A. Where exact types of hardware specified are not adaptable to finished shape or size of members requiring hardware, provide suitable types having as nearly as practical as the same operation and quality as type specified, subject to Architect’s approval.

1.7 SEQUENCING AND COORDINATION:

A. Coordinate with concrete.

B. Reinforce walls.

C. Coordinate finish floor materials and floor-mounted hardware.

D. Conduit and raceways as needed for electrical, electronic and electro-pneumatic hardware items. Fire/life-safety system interfacing. Point-to-point wiring diagrams plus riser diagrams to related trades.

E. Furnish manufacturer templates to door and frame fabricators.

F. Use hardware consultant to check Shop Drawings for doors and entrances to confirm that

adequate provisions will be made for proper hardware installation.

1. Confirm that door manufacturers furnish necessary UBC-7-2 compliant seal packages.

1.8 WARRANTY:

A. Part of respective manufacturers’ regular terms of sale. Provide manufacturers’ warranties:

1. Closers: Thirty years mechanical, two years electrical. 2. Exit Devices: Three years. 3. Hinges: Life of Building. 4. Other Hardware: Two years.

1.9 COMMISSIONING:

A. Test door hardware operation with climate control system and stairwell pressurization system both at rest and while in full operation.

B. Test electrical, electronic and electro-pneumatic hardware systems for satisfactory

operation.

C. Test hardware interfaced with fire/life-safety system for proper operation and release.

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-5

PART 2 - PRODUCTS 2.1 MATERIALS:

A. Provide hardware items required to complete the work in accordance with these specifications and manufacturers’ instructions.

1. Include items inadvertently omitted from this specification. Note these items in

submittal for review. 2. Where scheduled item is now obsolete, bid and furnish manufacturers updated

item at no additional cost to the project. 2.2 HANGING MEANS:

A. Conventional Hinges: Hinge open widths minimum, but, of sufficient throw to permit maximum door swing. Steel or stainless steel pins and concealed bearings.

1. Three hinges per leaf to 7 foot, 6 inch height. Add one for each additional 30

inches in height, or any fraction thereof. 2. Extra heavy weight hinges on doors over 3 foot, 5 inches in height. 3. Outswinging exterior doors: non-ferrous with non-removable (NRP) pins. 4. Non-ferrous material exteriors and at doors subject to corrosive atmospheric

conditions. 5. All hinges shall be non-removable tips – (NRP) 6. Provide shims and shimming instructions for proper door adjustment.

B. Continuous Hinges: Ives Aluminum Geared Continuous

1. UL 10C listed (90 minutes) 2. ANSI Certified-ANSI 156.25 Grade 2 3. Supports weights up to 450 lbs. 4’0” max. dr. width 4. Material to be extruded aluminum 6063-T6 5. Lengths- 83”,85”,95”, 120””- Custom Lengths available 6. Available Electric Modifications-EPT,TW, TWM, EC 7. All continuous geared hinges to be heavy duty-Amount of bearings varies by size

83”, 85”-32 bearings, 95”-36 bearings,120”-47 bearings a. Finishes Clear (CL)

2.3 LOCKSETS, LATCHSETS, DEADBOLTS:

A. General Requirements: 1. Locks shall be cylindrical and mortise locks with trim selected to match building

standard design, confirm trim before hardware submittal submission. Mfg. Schlage Lock Company – L-Series x 626

2. Meet with Architect and Owner to finalize keying requirements and obtain keying instructions in writing. Keying schedule shall be coordinated with Owner’s Locksmith in compliance with specific requirements determined in consultation with Owner.

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-6

3. Provide temporary construction keying system during construction period. Permanent keys shall be furnished to Owner’s Representative prior to occupancy. Owner or Owner’s Security Agent will void operation of construction keys.

4. All temporary cores and their Control Keys shall be returned to the supplier to avoid

additional charges.

B. Cylinders: 1. Permanent cylinders shall fit Schlage –PRIMUS-XP keyed as directed to a new

masterkey system and configured into sets or subsets, master keyed or great grand master keyed as directed by Owner.

2. All keying instruction, documents, and communications shall follow the format of the Door and Hardware Institute’s – Key System Nomenclature.

3. Permanent keys and cylinder cores shall be engraved with industry standard keying nomenclature. These visual key control marks or codes shall not include actual key cuts. a. Key and cylinder identification stamping shall be approved by Architect and

Owner. Failure to properly comply with these requirements shall be cause for replacement of cylinders and keys involved at no additional cost to Owner.

b. Functions as listed in hardware sets.

2.4 EXIT DEVICES/PANIC HARDWARE

A. Exit Devices – Von Duprin 99 Series General features:

1. Independent lab-tested 1,000,000 cycles. 2. Push-through touch pad design. No exposed touch bar fasteners, no exposed

cavities when operated. Return stroke fluid dampeners and rubber bottoming dampeners, plus anti-rattle devices.

3. ¾” throw deadlocking latchbolts. 4. No exposed screws to show through glass doors. 5. Non-handed basic device design with center case interchangeable with all

functions, no extra parts required to effect change of function. 6. Releasable with 32 lb. maximum pressure under 250 lb. load to the door.

B. Specific features:

1. Non-Fire Rated Devices: cylinder dogging. 2. Lever Trim: Breakaway type, forged brass or bronze escutcheon min .130”

thickness, match lockset lever design. 3. Rod and latch guards with surface vertical rod devices. 4. Fire-Labeled Devices: UL label indicating “Fire Exit Hardware”. Vertical rod

devices less bottom rod (LBR) unless otherwise scheduled. 5. Inpact recessed devices: 6. Delayed Egress Devices: Function achieved within single exit device component,

including latch, delayed locking device, request-to-exit switch, nuisance alarm, remote alarm, key switch, indicator lamp, relay, internal horn, door position

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-7

input, external inhibit input plus fire alarm input. NFPA 101 “Special Locking Arrangement” compliant.

7. Electrically Operated Devices: Single manufacturer source for electric latch retraction devices, electrically controlled trim, power transfers, power supplies, monitoring switches and controls.

8. Removable Mullions: Removable with single turn of building key. Securely reinstalled without need for key. Furnish storage brackets for securely stowing the mullion away from the door when removed.

2.5 CLOSERS

A. Surface Closers: LCN 4000/4040XP Series :

1. Full rack-and-pinion type cylinder with removable non-ferrous cover and cast iron body. Double heat-treated pinion shaft, single piece forged piston, chrome-silicon steel spring.

2. ISO 2000 certified. Units stamped with date-of-manufacture code. 3. Independent lab-tested 8,000,000 cycles. 4. Thru-bolts at wood doors unless doors are provided with closer blocking. Non-

sized, non-handed, and adjustable. Place closer inside building, stairs, and rooms.

5. Plates, brackets and special templating when needed for interface with particular header, door and wall conditions and neighboring hardware.

6. Opening pressure: Exterior doors 8.5 lb., interior doors 5 lb., labeled fire doors 15 lb.

7. Separate adjusting valves for closing speed, latching speed and backcheck, fourth valve for delayed action where scheduled.

8. Extra-duty arms (EDA) at exterior doors scheduled with parallel arm units. 9. Exterior door closers: tested to 100 hours of ASTM B117 salt spray test, furnish

data on request. 10. Exterior doors do not require seasonal adjustments in temperatures from 120

degrees F to –30 degrees F, furnish data on request. 11. Non-flaming fluid will not fuel door or floor covering fires. 12. Confirm mounting condition requirements for automatic door opener provide

proper arm required, mounting plates, and frame reinforcement as required for proper installation.

2.6 OTHER HARDWARE

A. Automatic Flush Bolts: Low operating force design, “LBR” type. B. Special pivot-hinges for gates – Bommer Industries – confirm door design for best

installation application - C. Overhead Stops: Stainless steel (100 series). Non-plastic mechanisms and finished metal

end caps. Field-changeable hold-open, friction and stop-only functions.

D. Kick Plates: Four beveled edges, .050 inches minimum thickness, height and width as scheduled. Sheet-metal screws of bronze or stainless steel to match other hardware.

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-8

E. Door Stops: Provide stops to protect walls, casework or other hardware.

1. Unless otherwise noted in Hardware Sets, provide wall type with appropriate

fasteners. Where wall type cannot be used, provide overhead type.

F. Seals: Finished to match adjacent frame color. Resilient seal material: solid high-grade neoprene. UL label applied to seals on rated doors. Substitute products: certify that the products equal or exceed specified material’s thickness and durability. Proposed substitutions: submit for approval. Manufacturer: Zero Manufacturing

G. Thresholds: As scheduled and per details. Substitute products: certify that the products equal or exceed specified material’s thickness. Proposed substitutions: submit for approval. 1. Exteriors: Set in full bed of butyl-rubber or polyisobutylene mastic sealant

complying with requirements in Division 7 “Thermal and Moisture Protection”. Non-ferrous ¼ inch fasteners and lead expansion shield anchors, or Red-Head #SFS-1420 (or approved equivalent) Flat Head Sleeve Anchors (SS/FHSL).

2. Each specific door opening requires field measurement and confirmation of their individual sill condition. Product specified is for this reason. Size the thresholds per opening, the excessive width may not be required, so this is a base-line for budget purposes.

3. Sound control openings: Set in bed of mastic sealant.

I. Fasteners: Generally, exposed screws to be Phillips or Robertson drive. Pinned TORX drive at high security areas. Flat head sleeve anchors (FHSL) may be slotted drive. Sheet metal and wood screws: full-thread. Sleeve nuts: full length to prevent door compression.

J. Silencers: Interior hollow metal frames, 3 for single doors, 4 for pairs of doors. Omit

where adhesive mounted seal occurs. Leave no unfilled/uncovered pre-punched silencer holes. Not required on doors receiving smoke gasketing.

2.7 FINISH:

A. Generally BHMA 626 Satin Chromium

1. Areas using BHMA 626 to have push-plates, pulls and protection plates of BHMA 630, Satin Stainless Steel, unless otherwise noted.

B. Door closers: factory powder coated to match other hardware, (BHMA 689) unless

otherwise noted. C. Aluminum items: match predominant adjacent material. Seals to coordinate with frame

color. 2.8 KEYING REQUIREMENTS:

A. Key System: Key to existing key system B. All cylinders and cores to be LFIC sized interchangeable core throughout and to be

combinated per the Owner’s instructions.

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-9

C. Furnish all locks & cylinders with temporary construction cores, plastic temp. Cores are not permitted.

D. Initiate and conduct meetings(s) with Owner’s Representative to determine the system keyway(s) and structure, Furnish Owner’s written approval of the system. 1. Furnish 12 construction keys. 2 Furnish 3 construction control keys. 3 Furnish 6 keys per change, 5 Master Keys per group and 3 Grand-Master keys

E. Cylinders/cores: keyed at factory of lock manufacturer where permanent records are maintained. All removable cores to be factory stamped with keying. Provide bitting list to Owner.

F. Permanent keys: secured shipment direct from point of origination to Owner. G. Bitting List: Secured shipment direct from point of origination to Owners completion.

PART 3 - EXECUTION 3.1 ACCEPTABLE INSTALLERS:

A. Factory trained, certified, and carries a factory-issued card certifying that person as a “Certified Installer”. Alternative: can demonstrate suitably equivalent competence and experience. Provide references upon request.

3.2 PREPARATION:

A. Ensure that walls and frames are square and plumb before hardware installation. B. Locate hardware per SDI-100 and applicable building, fire, life-safety, accessibility, and

security codes.

1. Notify Architect of any code conflicts before ordering material. 2. Where new hardware is to be installed near existing doors/hardware scheduled to

remain, match locations of existing hardware. C. Existing frames and doors scheduled to receive new hardware: carefully remove existing

hardware, tag and bag, and turn over to Owner.

1. Patch and fill wood frames and doors with solid wood stock or dowel material before cutting for new hardware. Do not reuse existing screw holes - - fill and re-pilot.

2. Metal doors/frames: Weld or fasten with screws: filler pieces in existing hardware cut-outs and mortises not scheduled for re-use by new hardware. Leave surfaces smooth - - no applied patches.

3.3 INSTALLATION

A. Install hardware per manufacturer’s instructions and recommendations. Do not install surface-mounted items until finishes have been completed on substrate. Set units level, plumb and true to line and location. Adjust and reinforce attachment substrate for proper installation and operation.

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-10

1. Gaskets: install jamb-applied gaskets before closers, overhead stops, rim strikes, etc. Install sweeps across bottoms of doors before astragals, cope sweeps around bottom pivots, trim astragals to tops of sweeps.

2. When hardware is to be attached to existing metal surface and insufficient reinforcement exists, use RivNuts, NutSerts or similar anchoring device for screws.

B. Locate floor stops not more than 4 inches from the wall. C. Drill pilot holes for fasteners in wood doors and/or frames. D. Lubricate and adjust existing hardware scheduled to remain. Carefully remove and give

to Owner items not scheduled for reuse.

3.4 FIELD QUALITY CONTROL.

A. Contractor shall employ and pay for services of a qualified independent Architectural Hardware Consultant (AHC) to perform inspections and to prepare inspection reports. Inspection Service:

B. After installation of door hardware is complete, the Awarded Hardware Distributor will inspect door hardware for proper application of finish hardware in compliance finish hardware schedule and keying schedule. In addition check hardware for adjustment and proper operation.

C. Contractor to provide written certification from a qualified AHC (Certified Architectural Hardware Consultant) that the hardware, cores and keying has been installed and tested in every door and is 100% complete for each phase or the total project whichever comes first

D. Prepare and submit, to Contractor, Architect, and Owner, a written report of inspection stating whether installed work complies with or deviates from requirements, including whether door hardware is properly installed and adjusted. Report shall be submitted within 3 days following site visits.

3.5 ADJUSTING

A. Initial Adjustment: 1. Adjust and check each operating item of door hardware and each door to ensure

proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended. Adjust door control devices to compensate for final operation of heating and ventilating equipment and to comply with referenced accessibility requirements.

2. Adjust door closer sweep period so that from an open position of 70 degrees door will take at least 3 seconds to move to a point 3” from latch measured to leading edge of door.

B. Final Adjustment: 1. Return to Project during week prior to Substantial Completion and make final

check and adjustment of hardware items.

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-11

2. Adjust hardware so doors operate in perfect order. Test and adjust hardware for quiet, smooth operation, free of sticking, binding, or rattling. Adjust closers for proper, smooth operation.

3. Adjust door control devices to compensate for final operation of heating and ventilating equipment.

C. Six Month Adjustment: 1. Approximately six months after Date of Substantial Completion, installer shall

perform following: a. Examine and readjust each item of door hardware as necessary to ensure

function of doors, door hardware. b. Consult with, and instruct, Owner’s personnel on recommended

maintenance procedures. c. Replace door hardware items that have deteriorated or failed due to faulty

design, materials, or installation.

D. Twelve Month Adjustment: 1. Approximately six months after Date of Substantial Completion, installer shall

perform following: a. Examine and readjust each item of door hardware as necessary to ensure

function of doors, door hardware. b. Consult with, and instruct, Owner’s personnel on recommended

maintenance procedures. c. Replace door hardware items that have deteriorated or failed due to faulty

design, materials, or installation.

3.6 CLEANING

A. Exposed hardware shall be carefully cleaned by methods not injurious to finish, immediately preceding occupancy. Replace defective, damaged, or missing hardware.

B. Clean adjacent surfaces soiled by hardware installation.

C. Clean operating items as needed to restore proper function and finish.

3.7 DEMONSTRATION

A. Engage a factory-authorized service representative to train Owner’s maintenance personnel to adjust, operate, and maintain door hardware and door hardware finishes.

3.8 PROTECTION

A. Provide final protection and maintain conditions that ensure door hardware shall be without damage or deterioration at time of Substantial Completion.

B. Protect door hardware items from abuse, corrosion and other damage until Owner accepts Project as complete.

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-12

3.9 SCHEDULE OF FINISH HARDWARE

Hardware Group No. 001

DOORS: B01D Each To Have: Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE 1 EA STOREROOM LOCK ND80TD SPA 626 SCH 1 EA PRIMUS CORE 20-740-XP 626 SCH 1 EA SURFACE CLOSER 1461 HCUSH FC TBSRT 689 LCN 1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE 1 EA WALL STOP WS406/407CCV 630 IVE 3 EA SILENCER SR64 GRY IVE

Hardware Group No. 002

DOORS: 103 105 Each To Have: Qty Description Catalog Number Finish Mfr

4 EA HW HINGE 5BB1HW 4.5 X 4.5 652 IVE 1 EA PRIVACY LOCK ND40S SPA 626 SCH 1 EA SURFACE CLOSER 4011 DEL SRI 689 LCN 1 EA ARMOR PLATE 8400 16" X 2" LDW B-CS 630 IVE 1 EA MOP PLATE 8400 4" X 1" LDW B4E 630 IVE 1 EA WALL STOP WS406/407CCV 630 IVE 1 EA DOOR SWEEP 8198AA AL ZER 3 EA SILENCER SR64 GRY IVE

Hardware Group No. 004

DOORS: 001 002 003 004 100A 100B 100C Each To Have: Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 112HD 628 IVE 1 EA PANIC HARDWARE CD-9949-EO 626 VON 1 EA PANIC HARDWARE CD-9949-NL-OP-110MD-249-BRAILLE

PBAR-WH-LBL-SEC-GBK 626 VON

1 EA RIM CYLINDER 20-057-ICX 626 SCH 2 EA MORTISE CYLINDER 20-061-ICX 626 SCH

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-13

3 EA PRIMUS CORE 20-740-XP 626 SCH 1 EA DOOR PULL VR910 DT 630 IVE 1 EA DOOR PULL VR910 NL 630 IVE 2 EA SURFACE CLOSER 4040XP SHCUSH SRI WMS 689 LCN 2 EA PA MOUNTING PLATE SRI 4040-18PA 689 LCN 2 EA CUSH SHOE SUPPORT SRI 4040-30 689 LCN 2 EA BLADE STOP SPACER SRI 4040-61 689 LCN 1 EA THRESHOLD 545A MSLA-10 AL ZER 1 BALANCE OF HARDWARE BY DOOR

SUPPLIER

2 DOOR CONTACT(S) BY OTHERS

Hardware Group No. 005

DOORS: 100D 100E 100F 100G Each To Have: Qty Description Catalog Number Finish Mfr

1 EA GATE HINGE 7112 626 BOM 1 EA PASSAGE SET ND10S SPA 626 SCH 2 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

Hardware Group No. 006

DOORS: 101 Each To Have: Qty Description Catalog Number Finish Mfr

1 EA GATE HINGE 7112 626 BOM 1 EA PASSAGE SET ND10S SPA 626 SCH 1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

Hardware Group No. 007

DOORS: 111 112 Each To Have: Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 652 IVE 1 EA ENTRANCE LOCK ND53TD SPA 626 SCH 1 EA PRIMUS CORE 20-740-XP 626 SCH 1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE 1 EA MOP PLATE 8400 4" X 1" LDW B4E 630 IVE

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-14

1 EA WALL STOP WS406/407CCV 630 IVE 3 EA SILENCER SR64 GRY IVE

Hardware Group No. 008

DOORS: 109 Each To Have: Qty Description Catalog Number Finish Mfr

4 EA HW HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE 1 EA POWER TRANSFER EPT10 689 VON 1 EA EU STOREROOM LOCK ND80TDEU SPA N123-062 626 SCH 1 EA PRIMUS CORE 20-740-XP 626 SCH 1 EA ELECTRIC STRIKE 7500C 630 HES 1 EA SURFACE CLOSER 4011 689 LCN 1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE 1 EA MOP PLATE 8400 4" X 1" LDW B4E 630 IVE 1 EA WALL STOP WS406/407CCV 630 IVE 1 EA GASKETING 429A A ZER 1 EA DOOR SWEEP 8198AA AL ZER 1 EA THRESHOLD 545A MSLA-10 AL ZER 1 EA DOOR VIEWER 698 626 IVE 3 EA SILENCER SR64 GRY IVE 1 EA CREDENTIAL READER BY CONTRACTOR TBD TBD 1 EA DOOR CONTACT 679-05HM BLK SCE 1 EA POWER SUPPLY PS902 900-BAT 900-2RS KL900 LGR VON 1 PROVIDE FACTORY POINT TO POINT

WIRING DIAGRAMS

1 PROVIDE RISER DIAGRAMS FREE EGRESS AT ALL TIMES-ENTER WITH CREDENTIAL OR KEY BY-PASS. CREDENTIAL READER BY SECURITY VENDOR. ELECTRONICALLY UNLOCKED - CONFIRM VOLTAGE AND CURRENT. DOOR IS MONITORED. REQUEST TO EXIT SWITCH.

Hardware Group No. 009

DOORS: B02 Each To Have: Qty Description Catalog Number Finish Mfr

6 EA HW HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE 2 EA MANUAL FLUSH BOLT FB458 626 IVE 1 EA STOREROOM LOCK ND80TD SPA 626 SCH 1 EA PRIMUS CORE 20-740-XP 626 SCH 1 EA SURFACE CLOSER 4011 SRI 689 LCN 2 EA CUSH SHOE SUPPORT SRI 4040-30 689 LCN 2 EA KICK PLATE 8400 34" X 1" LDW B-CS 630 IVE 2 EA FLOOR STOP FS444 626 IVE 1 EA GASKETING 429A A ZER

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-15

CONTINUOUS OVERLAPPING ASTRAGAL BY DOOR SUPPLIER.

Hardware Group No. 010

DOORS: 114 Each To Have: Qty Description Catalog Number Finish Mfr

1 EA CONT. HINGE 112HD 628 IVE 1 EA CONT. HINGE 112HD EPT 628 IVE 1 EA POWER TRANSFER EPT10 689 VON 2 EA MANUAL FLUSH BOLT FB458 626 IVE 1 EA EU STOREROOM LOCK ND80TDEU SPA N123-062 626 SCH 1 EA PRIMUS CORE 20-740-XP 626 SCH 1 EA OH STOP & HOLDER 100H 630 GLY 1 EA SURFACE CLOSER 4040XP SHCUSH SRI WMS 689 LCN 1 EA CUSH SHOE SUPPORT SRI 4040-30 689 LCN 2 EA KICK PLATE 8400 34" X 1" LDW B-CS 630 IVE 1 EA GASKETING 429A A ZER 1 EA ASTRAGAL 8192AA AA ZER 2 EA DOOR SWEEP 8198AA AL ZER 1 EA THRESHOLD 545A MSLA-10 AL ZER 1 EA CREDENTIAL READER BY CONTRACTOR TBD TBD 2 EA DOOR CONTACT 679-05HM BLK SCE 1 EA POWER SUPPLY PS902 900-BAT 900-2RS KL900 LGR VON

CONTINUOUS OVERLAPPING ASTRAGAL BY DOOR SUPPLIER. ; FREE EGRESS AT ALL TIMES-ENTER WITH CREDENTIAL OR KEY BY-PASS. CREDENTIAL READER BY SECURITY VENDOR. ELECTRONICALLY UNLOCKED - CONFIRM VOLTAGE AND CURRENT. DOOR IS MONITORED. REQUEST TO EXIT SWITCH.

Hardware Group No. 011

DOORS: ST00 Each To Have: Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 711CS 441 IVE 1 EA FIRE EXIT HARDWARE 9927-EO-F-LBR-499F 626 VON 1 EA FIRE EXIT HARDWARE 9975-L-NL-F-06-575-2 626 VON 2 EA END CAP BACK PLATE SEE PART II EXIT DEVICES 1 EA PRIMUS MORT. CYL. 20-763-XP 626 SCH 1 EA PRIMUS CORE 20-740-XP 626 SCH 2 EA SURFACE CLOSER 4040XP SCUSH SRI 689 LCN 2 EA CUSH SHOE SUPPORT SRI 4040-30 689 LCN 2 EA KICK PLATE 8400 34" X 1" LDW B-CS 630 IVE 1 SET SEALS 188S BLK ZER 1 EA GASKETING 429A A ZER 2 EA DOOR SWEEP 8198AA AL ZER 1 EA THRESHOLD 545A MSLA-10 AL ZER

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-16

CONTINUOUS OVERLAPPING ASTRAGAL - FULL WELDED - BY DOOR SUPPLIER.

Hardware Group No. 012

DOORS: B01A Each To Have: Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 711CS 441 IVE 1 SET CONST LATCHING

BOLT FB51P 630 IVE

1 EA PANIC HARDWARE LD-9975-L-NL-17 SS-630-575-2 630/626 VON 1 EA END CAP BACK PLATE SEE PART II EXIT DEVICES 1 EA PRIMUS MORT. CYL. 20-763-XP 626 SCH 1 EA PRIMUS CORE 20-740-XP 626 SCH 1 EA COORDINATOR COR X FL 628 IVE 2 EA MOUNTING BRACKET MB 689 IVE 2 EA SURFACE CLOSER 4040XP EDA SRI

- TEMPLATE FOR DEGREE OF OPENING WITH MAX. DEGREE TO ENGAGE STOP/HOLDERS.

689 LCN

2 EA KICK PLATE 8400 34" X 1" LDW B-CS 630 IVE 2 EA WALL STOP/HOLDER WS445 626 IVE 1 EA THRESHOLD 545A MSLA-10 AL ZER 2 EA SILENCER SR64 GRY IVE

Hardware Group No. 013

DOORS: ST01 Each To Have: Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 112HD EPT 628 IVE 2 EA POWER TRANSFER EPT10 689 VON 1 EA ELEC FIRE EXIT

HARDWARE WP-RX-9927-EO-F-LBR-ER36-499F - SPECIAL TEMPLATE REQUIRED.

626 VON

1 EA ELEC FIRE EXIT HARDWARE

WP-RX-EL-9975-L-NL-F-17 SS-630-575-2 630/626 VON

2 EA END CAP BACK PLATE SEE PART II EXIT DEVICES 1 EA INTERFACE BOX JB7 GRAY VON 1 EA PRIMUS MORT. CYL. 20-763-XP 626 SCH 1 EA PRIMUS CORE 20-740-XP 626 SCH 2 EA SURFACE CLOSER 4040XP SCUSH SRI

- SPECIAL TEMPLATE REQUIRED. 689 LCN

2 EA CUSH SHOE SUPPORT SRI 4040-30 689 LCN 2 EA KICK PLATE 8400 34" X 1" LDW B-CS 630 IVE 1 EA RAIN DRIP 142A AL ZER 1 EA JAMB SEAL 429A AL ZER 1 EA DOOR SWEEP 8198AA AL ZER 1 EA THRESHOLD 545A MSLA-10 AL ZER

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-17

1 EA CREDENTIAL READER BY CONTRACTOR TBD TBD 2 EA DOOR CONTACT 679-05HM BLK SCE 1 EA POWER SUPPLY PS914 900-BAT 900-2RS 900-4RL KL900 LGR VON

COORDINATE SECURITY CONTACT WITH SECURITY VENDOR - HOLLOW METAL DOOR SHALL BE PROVIDED WITH OVERLAPPING CONTINUOUSLY WELDED STEEL ASTRAGAL. ASTRAGAL SHALL NOT BE NOTCHED FOR STRIKE. - FREE EGRESS AT ALL TIMES - DOOR MONITORED - NOTE: RATED OPENING - METHOD OF OPERATION: FREE EGRESS AT ALL TIMES: ENTER WITH CREDENTIAL OR KEY BYPASS. COORDINATE WITH SECURITY VENDOR. CONTINUOUS OVERLAPPING ASTRAGAL - FULL WELDED - BY DOOR SUPPLIER.

Hardware Group No. 014

DOORS: B01B Each To Have: Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 711CS 441 IVE 1 SET CONST LATCHING

BOLT FB51P 630 IVE

1 EA PANIC HARDWARE 9975-L-NL-17 SS-630-575-2 LHR IS ACTIVE LEAF

630/626 VON

1 EA END CAP BACK PLATE SEE PART II EXIT DEVICES 1 EA PRIMUS MORT. CYL. 20-763-XP 626 SCH 1 EA PRIMUS CORE 20-740-XP 626 SCH 1 EA COORDINATOR COR X FL 628 IVE 2 EA MOUNTING BRACKET MB 689 IVE 1 EA SURFACE CLOSER 4040XP EDA SRI 689 LCN 1 EA SURFACE CLOSER 4040XP SCUSH SRI

- RHR DOOR ACTIVE. 689 LCN

1 EA CUSH SHOE SUPPORT SRI 4040-30 689 LCN 2 EA KICK PLATE 8400 34" X 1" LDW B-CS 630 IVE 2 EA WALL STOP/HOLDER WS445 626 IVE 2 EA SILENCER SR64 GRY IVE

Hardware Group No. 015

DOORS: 110 Each To Have: Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 652 IVE 1 EA PRIVACY LOCK ND40S SPA 626 SCH 1 EA SURFACE CLOSER 1461 DEL 689 LCN 1 EA ARMOR PLATE 8400 16" X 2" LDW B-CS 630 IVE 1 EA MOP PLATE 8400 4" X 1" LDW B4E 630 IVE 1 EA WALL STOP WS406/407CCV 630 IVE 3 EA SILENCER SR64 GRY IVE

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-18

Hardware Group No. 016

DOORS: B03 Each To Have: Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 711CS 441 IVE 1 SET CONST LATCHING

BOLT FB51P 630 IVE

1 EA STOREROOM LOCK ND80TD SPA 626 SCH 1 EA PRIMUS CORE 20-740-XP 626 SCH 1 EA COORDINATOR COR X FL 628 IVE 2 EA MOUNTING BRACKET MB 689 IVE 2 EA SURFACE CLOSER 4040XP SCUSH SRI

- SPECIAL TEMPLATE REQUIRED. 689 LCN

2 EA CUSH SHOE SUPPORT SRI 4040-30 689 LCN 2 EA KICK PLATE 8400 34" X 1" LDW B-CS 630 IVE 1 EA RAIN DRIP 142A AL ZER 1 EA GASKETING 429A A ZER 2 EA DOOR SWEEP 8198AA AL ZER 1 EA THRESHOLD 545A MSLA-10 AL ZER

CONTINUOUS OVERLAPPING ASTRAGAL - FULL WELDED - BY DOOR SUPPLIER.

Hardware Group No. 017

DOORS: 113A Each To Have: Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 NRP 652 IVE 1 EA STOREROOM LOCK ND80TD SPA 626 SCH 1 EA PRIMUS CORE 20-740-XP 626 SCH 1 EA SURFACE CLOSER 1461 689 LCN 1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE 1 EA KICK PLATE 8400 4" X 1 1/2" LDW B4E 630 IVE 1 EA WALL STOP WS406/407CCV 630 IVE 3 EA SILENCER SR64 GRY IVE

Hardware Group No. 018

DOORS: 108 Each To Have:

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-19

Qty Description Catalog Number Finish Mfr 4 EA HW HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE 1 EA CLASSROOM LOCK ND70TD SPA 626 SCH 1 EA PRIMUS CORE 20-740-XP 626 SCH 1 EA OH STOP & HOLDER 100H 630 GLY 1 EA SURFACE CLOSER 1461 689 LCN 1 EA ARMOR PLATE 8400 16" X 2" LDW B-CS 630 IVE 1 EA KICK PLATE 8400 4" X 1 1/2" LDW B4E 630 IVE 1 EA GASKETING 429A A ZER 1 EA DOOR SWEEP 8198AA AL ZER 1 EA THRESHOLD 65A MSLA-10 AL ZER

Hardware Group No. 019

DOORS: B01E Each To Have: Qty Description Catalog Number Finish Mfr

4 EA HW HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE 1 EA STOREROOM LOCK ND80TD SPA 626 SCH 1 EA PRIMUS CORE 20-740-XP 626 SCH 1 EA SURFACE CLOSER 1461 689 LCN 1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE 1 EA WALL STOP WS406/407CCV 630 IVE 3 EA SILENCER SR64 GRY IVE

Hardware Group No. 020

DOORS: 115 Each To Have: Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE 1 EA STOREROOM LOCK ND80TD SPA 626 SCH 1 EA PRIMUS CORE 20-740-XP 626 SCH 1 EA SURFACE CLOSER 1461 689 LCN 1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE 1 EA WALL STOP WS406/407CCV 630 IVE 3 EA SILENCER SR64 GRY IVE

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-20

Hardware Group No. 021

DOORS: 113B Each To Have: Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 NRP 652 IVE 1 EA POWER TRANSFER EPT10 689 VON 1 EA EU STOREROOM LOCK ND80TDEU SPA N123-062 626 SCH 1 EA PRIMUS CORE 20-740-XP 626 SCH 1 EA WALL STOP WS406/407CCV 630 IVE 3 EA SILENCER SR64 GRY IVE 1 EA CREDENTIAL READER BY CONTRACTOR TBD TBD 1 EA POWER SUPPLY PS902 900-BAT 900-2RS KL900 LGR VON 1 PROVIDE FACTORY POINT TO POINT

WIRING DIAGRAMS

1 PROVIDE RISER DIAGRAMS

Hardware Group No. 022

DOORS: 104B 106B Each To Have: Qty Description Catalog Number Finish Mfr

4 EA HW HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE 1 EA CLASSROOM DEAD

LOCK L463T 626 SCH

1 EA PRIMUS CORE 20-740-XP 626 SCH 1 EA DOOR PULL VR814 DT 630 IVE 1 EA OH STOP & HOLDER 100H 630 GLY 1 EA ARMOR PLATE 8400 16" X 2" LDW B-CS 630 IVE 1 EA MOP PLATE 8400 4" X 1" LDW B4E 630 IVE 1 EA WALL STOP WS406/407CCV 630 IVE 3 EA SILENCER SR64 GRY IVE

Hardware Group No. 023

DOORS: 104 104A 106 106A Each To Have: Qty Description Catalog Number Finish Mfr

4 EA HW HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE 1 EA PASSAGE SET ND10S SPA 626 SCH 1 EA SURFACE CLOSER 4040XP SCUSH SRI 689 LCN

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-21

1 EA CUSH SHOE SUPPORT SRI 4040-30 689 LCN 1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE 1 EA WALL STOP WS406/407CCV 630 IVE 1 EA DOOR SWEEP 8198AA AL ZER 3 EA SILENCER SR64 GRY IVE

Hardware Group No. 024

DOORS: 113 Each To Have: Qty Description Catalog Number Finish Mfr

1 EA CONT. HINGE 112HD EPT 628 IVE 1 EA POWER TRANSFER EPT10 689 VON 1 EA ELEC PANIC

HARDWARE WP-RX-EL-33A-NL-OP-388 626 VON

1 EA PRIMUS RIM CYLINDER 20-757-XP 626 SCH 1 EA PRIMUS CORE 20-740-XP 626 SCH 1 EA 90 DEG OFFSET PULL 8190HD 12" O 630 IVE 1 EA SURFACE CLOSER 4040XP SCUSH SRI 689 LCN 1 EA PA MOUNTING PLATE SRI 4040-18PA 689 LCN 1 EA CUSH SHOE SUPPORT SRI 4040-30 689 LCN 1 EA BLADE STOP SPACER SRI 4040-61 689 LCN 1 EA RAIN DRIP 142A AL ZER 1 EA THRESHOLD 65A MSLA-10 AL ZER 1 EA CREDENTIAL READER BY CONTRACTOR TBD TBD 1 EA DOOR CONTACT 679-05HM BLK SCE 1 EA POWER SUPPLY PS914 900-BAT 900-2RS 900-4RL KL900 LGR VON 1 BALANCE OF HARDWARE BY DOOR

SUPPLIER

1 PROVIDE FACTORY POINT TO POINT WIRING DIAGRAMS

1 PROVIDE RISER DIAGRAMS FREE EGRESS AT ALL TIMES-ENTER WITH CREDENTIAL OR KEY BY-PASS. CREDENTIAL READER BY SECURITY VENDOR. ELECTRONICALLY UNLOCKED - CONFIRM VOLTAGE AND CURRENT. DOOR IS MONITORED. REQUEST TO EXIT SWITCH.

Hardware Group No. 025

DOORS: 102 Each To Have: Qty Description Catalog Number Finish Mfr

1 EA CONT. HINGE 112HD 628 IVE 1 EA DEADLATCH 4911W-4591 628 ADA 1 EA PRIMUS MORT. CYL. 20-766

- PROVIDE TEMP CORE. 626 SCH

SECTION 087100 – FINISH HARDWARE

FINISH HARDWARE 087100-22

1 EA PRIMUS CORE 20-740-XP 626 SCH 1 EA 90 DEG OFFSET PULL 8190HD 12" O 630 IVE 1 EA SURFACE CLOSER 4040XP SCUSH 689 LCN 1 EA PA MOUNTING PLATE SRI 4040-18PA 689 LCN 1 EA CUSH SHOE SUPPORT SRI 4040-30 689 LCN 1 EA BLADE STOP SPACER SRI 4040-61 689 LCN 1 EA THRESHOLD 545A MSLA-10 AL ZER 1 BALANCE OF HARDWARE BY DOOR

SUPPLIER

1 DOOR CONTACT(S) BY OTHERS

Hardware Group No. 026

DOORS: 116A 117A Each To Have: Qty Description Catalog Number Finish Mfr

1 EA CONT. HINGE 112HD 628 IVE 1 EA PANIC HARDWARE CD-99-NL-OP-110MD 626 VON 1 EA RIM CYLINDER 20-057-ICX 626 SCH 1 EA MORTISE CYLINDER 20-061-ICX 626 SCH 2 EA PRIMUS CORE 20-740-XP 626 SCH 1 EA DOOR PULL VR914 NL 630 IVE 1 EA SURFACE CLOSER 4040XP SCUSH SRI 689 LCN 1 EA PA MOUNTING PLATE SRI 4040-18PA 689 LCN 1 EA CUSH SHOE SUPPORT SRI 4040-30 689 LCN 1 EA BLADE STOP SPACER SRI 4040-61 689 LCN 1 EA THRESHOLD 545A MSLA-10 AL ZER 1 BALANCE OF HARDWARE BY DOOR

SUPPLIER

VA

RIE

S

VARIES

VA

RIE

S

VARIES

VA

RIE

S

10"

6"

6" 6"

VARIES

FLUSH FLUSH DOUBLE FULL GLASS

T

F F2 G

VARIES

DOUBLE GATE(SEE ELEVATIONS)

A

VA

RIE

S

VARIES

GATE(SEE ELEVATIONS)

B

VA

RIE

S

SECURITY GATE

C

ADA SECURITY GATE

D

RECEPTION DOOR

E

PROVIDEWHEELCHAIRGRAPHIC

VA

RIE

S

VARIES

DEFAULT FRAME

VA

RIE

S

VARIES

F1

DEFAULT FRAME

F2

2" 2"

2"

2" 2"

2"

3' -

0"

5' -

0"

12' - 0"

D

EQ EQ EQ

C2

A-611

Sim

A2

A-611

T T T

B3

A-611

B

3' - 0"

4' -

0"

3' -

0"

C2

A-611

Sim

A1

A-611

T

B3

A-611

E1

3' -

0"

5' -

0"

5' - 0"

EQ EQ

A3

A-611

T T

B5

A-611

C3

A-611

F

6

10' -

0"

T T T T T

2' - 8"1' - 7"1' - 7"2' - 8" EQ.EQ.

2' -

0"

5' -

2"

2' -

10"

A5

A-611

Sim

D1

A-324

Sim

G

2' - 9" 3' - 0" 2' - 9"

7' -

0"

3' -

0"

6

10' -

0"

A6

A-611

B1

A-611

C1

A-611

T T

TTT

D1

A-324

Sim

B2

A-611

5' - 0"

EQ EQ

3' -

0"

5' -

0"

E2

A3

A-611

T T

B5

A-611

C3

A-611

C

3' -

0"

4' -

0"

7' - 4"

3' - 4"EQ. EQ.

4' -

0"

3' -

0"

C2

A-611

Sim

A1

A-611

T T T

B3

A-611

FIRST FLOOR100' - 0"

3' -

0"

5' -

0"

3' - 0"

A

C2

A-611

Sim

A1

A-611

T

B3

A-611

1

2' -

0"

8' - 0"4' - 0"

1' -

4"

2

C5

A-611

TYP.

2' - 8"

2' -

0"

3

1' - 2"

1' -

0"

4

10"

1' - 0"

5

2' - 0"

1' -

0"

6

2' - 6"

1' -

0"

7

4' - 0"

1' -

4"

8

SEAL

KEY PLAN

Copyright 2015 © Hughes Group Architects

A

B

C

D

123456

PR

OJE

CT

AD

DR

ES

S:

PR

OJ. N

O:

OW

NE

R:

ISSUANCES

DATE ISSUANCE

REVISIONS

02/16/2017

22630 DAVIS DRIVE, SUITE 175STERLING, VIRGINIA 20164

703.437.6600

FO

R D

RC

A U

SE

EA

ST

PO

TO

MA

C P

OO

L

A-601

SCHEDULES

1505

DC

DE

PA

RT

ME

NT

OF

GE

NE

RA

L S

ER

VIC

ES

100% CD03-15-2017

972 O

HIO

DR

, S

W, W

AS

HIN

GT

ON

, D

C 2

0024

DOOR SCHEDULE

NUMBER

DOOR FRAME DETAILS

RATING

HARDWAREREMARKS

TYPE WIDTH HEIGHT PAIR MAT FIN TYPE MAT FIN HEAD JAMB SILL SET NO. FUNCTION

BASEMENT LEVEL

B01A F2 6' - 0" 7' - 0" YES FG FG-1 F2 FG FG-1 H1 J1 - 1 HR 012 STOREROOM 3, 7

B01B F2 6' - 0" 7' - 0" YES FG FG-1 F2 FG FG-1 H1 J1 - 1 HR 014 STOREROOM 3, 7

B01D F 3' - 0" 7' - 0" - FG FG-1 F1 FG FG-1 H1 J1 - - 001 STOREROOM 3, 7

B01E F 3' - 6" 7' - 0" - FG FG-1 F1 FG FG-1 H1 J1 - - 019 STOREROOM 3, 7

B02 F2 6' - 0" 7' - 0" YES FG FG-1 F2 FG FG-1 H1 J1 S1 - 009 STOREROOM 3, 7

B03 F2 6' - 0" 7' - 0" YES FG FG-1 F2 FG FG-1 H1 J1 - - 016 PASSAGE 3, 8

ST00 F2 6' - 0" 7' - 0" YES FG FG-1 F2 FG FG-1 H1 J1 S1 1 HR 011 STOREROOM 3, 8

FIRST FLOOR

001 A 4' - 0" 7' - 0" YES AL PTD - - - - - - - 004 ENTRY/EGRESS 1

002 A 4' - 0" 7' - 0" YES AL PTD - - - - - - - 004 ENTRY/EGRESS 1

003 A 4' - 0" 7' - 0" YES AL PTD - - - - - - - 004 ENTRY/EGRESS 1

004 A 4' - 0" 7' - 0" YES AL PTD - - - - - - - 004 ENTRY/EGRESS 1

100A A 6' - 0" 8' - 0" YES AL PTD - - - - - - - 004 ENTRY/EGRESS 1

100B A 4' - 0" 8' - 0" YES AL PTD - - - - - - - 004 ENTRY/EGRESS 1

100C A 6' - 0" 8' - 0" YES AL PTD - - - - - - - 004 ENTRY/EGRESS 1

100D D 3' - 0" 4' - 0" - AL - - - - - - - - 005 PASSAGE 4

100E C 3' - 0" 4' - 0" - AL - - - - - - - - 005 PASSAGE 2, 4, 5

100F C 3' - 0" 4' - 0" - AL - - - - - - - - 005 PASSAGE 2, 4, 5

100G D 3' - 0" 4' - 0" - AL - - - - - - - - 005 PASSAGE 4

101 E 3' - 0" 2' - 8" - - HDPE-1 - - - - - - - 006 PASSAGE 4, 5

102 G 3' - 0" 7' - 0" - AL - - AL - C1/A611 B2/A611 B1/A611 - 025 OFFICE 3

103 F 3' - 0" 7' - 10" - HM HPC-6 F1 HM HPC-6 H1 J1 S1 - 002 PRIVACY BATH 3, 6

104 F 3' - 0" 7' - 10" - HM HPC-6 F1 HM HPC-6 H1 J1 S1 - 023 PASSAGE 3, 5

104A F 3' - 0" 7' - 10" - HM HPC-6 F1 HM HPC-6 H1 J1 S1 - 023 PASSAGE 3, 5

104B F 3' - 0" 7' - 10" - HM HPC-6 F1 HM HPC-6 H1 J1 - - 022 STOREROOM

105 F 3' - 0" 7' - 10" - HM HPC-6 F1 HM HPC-6 H1 J1 S1 - 002 PRIVACY BATH 3, 6

106 F 3' - 0" 7' - 10" - HM HPC-6 F1 HM HPC-6 H1 J1 S1 - 023 PASSAGE 3, 5

106A F 3' - 0" 7' - 10" - HM HPC-6 F1 HM HPC-6 H1 J1 S1 - 023 PASSAGE 3, 5

106B F 3' - 0" 7' - 10" - HM HPC-6 F1 HM HPC-6 H1 J1 - - 022 STOREROOM

108 F 3' - 0" 7' - 10" - HM HPC-6 F1 HM HPC-6 H2 J2 S1 - 018 CLASSROOM 3, 5, 9

109 F 3' - 0" 7' - 10" - HM HPC-6 F1 HM HPC-6 H2 J2 S1 - 008 CLASSROOM 3

110 F 3' - 0" 7' - 0" - HM HPC-6 F1 HM HPC-6 H1 J1 - - 015 PRIVACY BATH 3

111 F 3' - 0" 7' - 0" - HM HPC-6 F1 HM HPC-6 H1 J1 - - 007 OFFICE

112 F 3' - 0" 7' - 0" - HM HPC-6 F1 HM HPC-6 H1 J1 - - 007 OFFICE

113 G 3' - 0" 7' - 10" - AL - - AL - C3/A611 B3/A611 B1/A611 - 024 CLASSROOM 3, 9

113A F 3' - 0" 7' - 0" - HM HPC-6 F1 HM HPC-6 H1 J1 - - 017 STOREROOM

113B F 3' - 0" 7' - 0" - HM HPC-6 F1 HM HPC-6 H1 J1 - - 021 STOREROOM 3, 9

114 F2 6' - 0" 7' - 10" YES HM HPC-6 F2 HM HPC-6 H2 J2 S2 - 010 STOREROOM 3, 5, 7, 9

115 F 3' - 0" 7' - 0" - FG FG-1 F1 FG FG-1 H1 J1 - - 020 STOREROOM 3, 7

116A B 4' - 0" 6' - 0" - AL PTD - - - - - - - 026 ENTRY/EGRESS 1

117A B 4' - 0" 6' - 0" - AL PTD - - - - - - - 026 ENTRY/EGRESS 1

ST01 F2 6' - 0" 7' - 10" YES HM HPC-6 F2 HM HPC-6 H2 J2 S2 - 013 STOREROOM 8, 9

INTERIOR MATERIAL & COLOR LEGENDDESIGNATION MATERIAL MANUFACTURER / PRODUCT NUMBER / COLOR REMARKS

ACT-1 ACOUSTIC CEILING TILE ARMSTRONG / DUNE WHITE 2x2, PRELUDE XL GRID

ACT-2 MOISTURE RESISTANT ACOUSTIC CEILING TILE ARMSTRONG / KITCHEN ZONE WHITE 2x2, PRELUDE XL FIRE GUARD GRID

AL-1 ALUMINUM PANEL TBD - TO 8'-0" A.F.F. AT CONCESSIONS &PANTRY

CT-1 PORCELAIN TILE DALTILE / KEYSTONES D169/ WATERFLL 2"X4", STRAIGHT JOINT MOSAIC @SHOWER WALL, EPOXY GROUT-WHITE

HDPE-1 HIGH DENSITY POLYETHYLENE SCRANTON PRODUCTS/ HINY HIDERS SANDSTONE TOILET AND SHOWER PARTITIONS

HDPE-2 HIGH DENSITY POLYETHYLENE KING PLASTIC DOLPHIN GRAY OUTDOOR CABINETRY

HPC-3 HIGH PERFORMANCE COATING (WALL) TNEMEC 07WH / WINTER MIST(WHITE)

-

HPC-4 HIGH PERFORMANCE COATING (WALL ACCENT) TNEMEC 04BL / BLUEBELL(BLUE)

-

HPC-5 HIGH PERFORMANCE COATING (CEILING) TNEMEC 07WH / WINTER MIST(WHITE)

-

HPC-6 HIGH PERFORMANCE COATING (TRIM) TNEMEC 35BL / ACADEMY BLUE

MR-1 MOISTURE RESISTANT GYPSUM BOARD SEE SPECS PTD HPC-5 AT SHOWER CEILINGS

SC-1 SEALED CONCRETE TBD TBD / TBD -

SS-1 SOLID SURFACE COUNTERTOP DUPONT/CORIAN DEEP CLOUD -

V-1 SHEET VINYL ECORE / PEARLAZZO PUR 9704 / MINERAL -

V-2 SLIP RESISTANT SHEET VINYL POLYFLOR / POLYSAFE APEX 4204 / BRECCIA -

VB-1 VINYL BASE JOHNSONITE 71 /STORM CLOUD 4"

FINISH SCHEDULESPACE DESCRIPTION SPACE FINISHES

REMARKS# ROOM NAME FLOOR BASE WALLS CEILING

BASEMENT LEVEL

B01 POOL FILTER ROOM SC-1 - HPC-3 EXP / HPC-5 -

B01A CHLORINE ROOM SC-1 - HPC-3 EXP / HPC-5 -

B01B ACID / CO2 ROOM SC-1 - HPC-3 EXP / HPC-5 -

B01C BACKWASH TANK SC-1 - HPC-3 EXP / HPC-5 -

B01D WATER SERVICE SC-1 - HPC-3 EXP / HPC-5 -

B01E PUMP RM SC-1 - HPC-3 EXP / HPC-5 -

B02 STORAGE SC-1 - HPC-3 EXP / HPC-5 -

B03 AREAWAY SC-1 - HPC-3 EXP / HPC-5 -

ST00 STAIR SC-1 - HPC-3 EXP / HPC-5 -

FIRST FLOOR

100 LOBBY - - - - SEE EXTERIOR MATERIALS LEGEND FOR MATERIALS

101 CHECK-IN - - - - -

102 MEET ROOM V-1 VB-1 HPC-3 ACT-1 -

103 FAMILY CHANGING ROOM SC-1 - HPC-3 EXP / HPC-5 BULL FLOAT FINISH @ SHOWER FLOOR, CT-1 @ SHOWERWALLS, BULLNOSE TILE @ OUTSID EDGES

104 WOMEN'S LOCKER ROOM SC-1 - HPC-3 / HPC-4 EXP / HPC-5 BULL FLOAT FINISH @ SHOWER FLOOR, CT-1 @ SHOWERWALLS, BULLNOSE TILE @ OUTSID EDGES

104B JAN CLO SC-1 - HPC-3 EXP / HPC-5 -

105 FAMILY CHANGING ROOM SC-1 - HPC-3 EXP / HPC-5 BULL FLOAT FINISH @ SHOWER FLOOR, CT-1 @ SHOWERWALLS, BULLNOSE TILE @ OUTSID EDGES

106 MEN'S LOCKER ROOM SC-1 - HPC-3 / HPC-4 EXP / HPC-5 BULL FLOAT FINISH @ SHOWER FLOOR, CT-1 @ SHOWERWALLS, BULLNOSE TILE @ OUTSID EDGES

106B JAN CLO SC-1 - HPC-3 EXP / HPC-5 -

107 CONCESSIONS SC-1 VB-1 HPC-3 / AL-1 ACT-2 -

108 PANTRY SC-1 VB-1 HPC-3 /AL-1 ACT-2 -

109 OPEN OFFICE V-1 VB-1 HPC-3 ACT-1 -

110 STAFF TOILET V-1 VB-1 HPC-3 ACT-1 -

111 SWIM INSTRUCTOR V-1 VB-1 HPC-3 ACT-1 -

112 DIRECTOR'S OFFICE V-1 VB-1 HPC-3 ACT-1 -

113 SAFETY CENTER V-1 VB-1 HPC-3 ACT-1 -

113A STORAGE SC-1 - HPC-3 EXP / HPC-5 -

113B UTILITY/IT SC-1 - HPC-3 EXP / HPC-5 -

114 POOL STORAGE SC-1 - HPC-3 EXP / HPC-5 -

115 ELECTRICAL SC-1 - HPC-3 EXP / HPC-5 -

116A COLONNADE - - - - SEE EXTERIOR MATERIALS LEGEND FOR MATERIALS

116B RAMP - - - - SEE EXTERIOR MATERIALS LEGEND FOR MATERIALS

117A COLONNADE - - - - SEE EXTERIOR MATERIALS LEGEND FOR MATERIALS

117B RAMP - - - - SEE EXTERIOR MATERIALS LEGEND FOR MATERIALS

ST01 STAIR SC-1 - HPC-3 EXP / HPC-2 -

SCALE: 1/4" = 1'-0"

DOOR LEGENDSCALE: 1/4" = 1'-0"

FRAME LEGEND

SCALE: 1/4" = 1'-0"A1ELEVATIONS - WINDOW STOREFRONTS

1. PROVIDE PANIC HARDWARE WITH OUTSIDE TEMPERING PROTECTION2. ACCESSIBLE ADA GATE WITH KICKPLATE3. PROVIDE DOOR CLOSER4. SPRING LOADED CLOSER5. KICK PLATE6. OCCUPIED/UNOCCUPIED INDICATOR7. PROVIDE FIBERGLASS DOORS AND FRAMES AT CHEMICAL STORAGE

LOCATIONS8. PROVIDE STAINLESS TYPE 316 - HIGH CORROSION RESISTANT-SHOP

PASSIVATED PER ASTM A-967 FOR DOORS AND FRAMES

DOOR SCHEDULE REMARKS

SCALE: 1/4" = 1'-0"B1ELEVATION - LOUVERS

HM: HOLLOW METALAL: ALUMINUMFG: FIBERGLASS

MARK DATE ISSUE

1 05/19/2017 BID REVISION 1

1

1