Upload
hw
View
0
Download
0
Embed Size (px)
Citation preview
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 2 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
TABLE OF CONTENT
ITEM DESCRIPTION PAGE
BUILDING SURVEY REPORT
1.0 INTRODUCTION
1.1 Instructions 4
2.0 BUILDING TYPE 1: 18th Century
2.1 Description of Property 5
2.2 Common defects and typical locations 6
2.3 Suitable investigative approach for defect 7
2.4 Pro’s and Con’s of investigative technique 7
2.5 Suggested repairs intervention 8
3.0 BUILDING TYPE 2: 19th Century
3.1 Description of Property 9
3.2 Common defects and typical locations 10
3.3 Suitable investigative approach for defect 10
3.4 Pro’s and Con’s of investigative technique 11
3.5 Suggested repairs intervention 12
4.0 BUILDING TYPE 3: 20th Century
4.1 Description of Property 14
4.2 Common defects and typical locations 15
4.3 Suitable investigative approach for defect 15
4.4 Pro’s and Con’s of investigative technique 16
4.5 Suggested repairs intervention 17
5.0 CONCLUSIONS & RECOMMENDATIONS
5.1 Conclusions 19
5.2 Recommendations 20
6.0 PERSONAL REFLECTION 22
7.0 REFERENCE 24
APPENDICE
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 3 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
BUILDING SURVEY REPORT
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 4 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
1.0 INTRODUCTION
1.1 Instructions
CMM Conservation Consultant Inc. was employed by TF Properties Ltd. to conduct
building survey and advise on common defects identified associated with the
architectural 3 periods (18th century, 19th Century and 20th Century building).
Suitable non-destructive and destructive techniques will be proposed to identify the
defects. Pros and cons of the proposed technique will be discussed. The most suitable
repair and remedial work to such defects will be proposed and adopted.
At the end of this report, a summary of the survey and recommendation will be made
for the “due diligence”. Hence the investment option will be concluded.
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 5 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
2.0 BUILDING TYPE 1: 18th CENTURY
2.1 Description of Property
Nga Tsin Wai Tsuen Walled Village gatehouse was situated at the said village located
at the turning corner of Kai Tak River with Tung Lung Road and Tung Kwong Road
on both sides, San Po Kong, Kowloon, Hong Kong. Nga Tsin Wai Village is a walled
village established by three clans, Chan clan, Lee clan and Ng clan.
It is believed that the Walled Village was built in Ming Dynasty. In the early Qing
Dynasty, the Qing government forced the population to withdraw inland about 17
miles from the coast to stop their collusion with the Ming loyalist Cheng chenggong
in Taiwan. Members of three clans returned to Kowloon City and rebuilt their village
in the 2nd year of Yongzheng era (1724) in the Qing Dynasty. The gatehouse at the
entrance of village with the entire village surrounded by moat and a drawbridge for
access, reflecting the high security system it once possessed.
The Gatehouse and Tin Hau Temple are the most outstanding buildings of the village.
Their location along the central axial lane, which is the main access of the entire
village, reflected their significance.
The Gatehouse is a one-hall two-storey building of one jian in width. The entrance
wall is very thick, of around 1.3 meter thick for security reason. It has a granite door
surround.
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 6 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
Walled village is a kind of traditional building which is completely surrounded by
thick defensive walls, protecting the residents from the attack of wild animals and
enemies. Usually, people living in the walled village are extended families or clans
sharing the same surname. Gatehouse is usually constructed for security aspect of the
clans. Walled villages can be found in mainland China and Hong Kong. Nga Tsin Wai
Village in San Po Kong is the one of the few walled villages left in the urban built-up
areas of Hong Kong.
2.2 Common defects and typical locations
The structure of the gatehouse was made from granite and masonry with paint finish
on plastered substrate. Some loosen plaster found at the lowest outer corner of the
semi-circular archway.
It found that a crack developed at outer boundary edge of wall of the gatehouse. It is
the party wall to neighbor building. It seems some plaster work have been applied
before to cover the crack, however it could not successfully terminate the crack
development.
Some painting had been peeled off and showed sign of dampness problem over the
exterior wall.
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 7 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
2.3 Suitable investigative approach for defect
The loosen plaster should be tested by hammer tapping to identify whether the plaster
was broken by external forces or by the inferior deterioration such as plaster
workmanship or material failure.
Crack appearing at the outer boundary edge may be suspected be the structural crack
when uneven distributed load or movement applying. It is proposed to conduct glass
tell-taler survey to monitor crack movement prior remedial action to be taken.
For the painting peeled off and fungi development, the common cause is the damping
problem at this case. It is proposed to conduct visual investigation to identify the area
of damping.
2.4 Pro’s and Con’s of investigative technique
By the hammer tapping test is an easy approach to test the condition of surrounding
plastering. It help us to identify whether a continuously developed or locally formed
of the loosen plaster. It involves the experienced and trained personel belongs with
tapping rod to complete the test. By sound generated by vibration during tapping,
result obtained effectively and immediately after test. However, hammer tapping test
relies on the experience of testing personnel and sometimes be a subjective judgement.
Even though two experienced person may advise a different interpretation of the
sound and lead to a dispute.
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 8 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
Glass tell-taler test is the simplest and cheapest crack-monitoring device. The initial
reading records and periodically checks for deviation vertically and horizontally. But
it is limited by lack of any calibration and vulnerability to external damaging. It also
takes long time to acquire data.
Visual inspection for fungus development area is easy, direct and no special
equipment involvement. However, result is highly tolerated and rely experience and
knowledge of inspector and moderate risk on accuracy by human error.
2.5 Suggested repairs intervention
For the plaster repairing, it is suggested to ensure a sound substrate prepared. Remove
all local and surrounding defective plaster to identify the de-bonding condition. The
proprietary repair mortar is suggested to make good the plaster. For those substrate
defects identified, it is recommended to seek structural engineer’s advice to repair the
structural substrate.
Re-pointing to the crack is the primary recommendation provided that it is not as
worse as structural failure threatening. Proprietary product should be used in this case
to ensure a proper bonding to be resulted in the structure. Periodic monitoring is the
key issue to identify effectiveness of remedial work.
It is proposed to remove all existing painting and repaint with anti-mound and
anti-fungus function.
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 9 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
3.0 BUILDING TYPE 1: 19th CENTURY
3.1 Description of Property
St. Joseph Chapel was located in Yim Tin Tsai Island, Sai Kung, Hong Kong. This
chapel was completed and blessed 1890. The chapel has all along been playing a
major role in defining the principal character of the Yim Tin Tsai being a Roman
Catholic community and differentiating it from the majority of the rural communities
in Sai Kung which are villages believing in traditional Chinese deities.
St. Joseph’s Chapel was the sixth chapel in the Sai Kung area. It is of the typical late
19th century rural New Territories style Roman Catholic chapel and is very well
preserved. It is believed that it was designed by an Italian priest because its
architectural style is close to Italian Romanesque.
The Chapel measures 24m x 9m which is a massive structure compared to the rest of
the buildings on the island. It is surrounded by a ram-earth wall which is still visible
nowadays.
There were colourful stained glassed on the original windows of the Chapel, but they
were replaced by ordinary glasses during the major renovations in 1948 and 1962. In
the recent refurbishment completed in April 2004, stained glasses are used on the
Chapel’s window once again.
For more than a century, St. Joseph’s Chapel has been the most prominent landmarks
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 10 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
of Yim Tin Tsai, signifying the influence of not only the Roman Catholics, but also
the villagers themselves in creating the character of the cultural landscape.
3.2 Common defects and typical locations
The old roof of the Chapel had been removed and replaced by corrugated metal sheet
panel to simulate the original pitched roof. It found some water stain appearing at the
interior wall just neighborhood of the roofing support frame. Some mould developed
and found at the structural beam of the chapel.
The structure of the St. Joseph’s Chapel was made from brickwork and masonry with
paint finish on plastered substrate. Some painting had been peeled off and cracks
could be found at the lowest corner of column.
3.3 Suitable investigative approach for defect
It is quite common the joint between different materials (metal framework connected
to masonry wall) may not adhere very well and form a weak point during rainy day. If
the nail connection for corrugated sheet to metal frame not be sealed very well. Water
may come and appear through the weak point. For the suspected leakage of roof, it
may use Infrared scanning technique to identify the ingress of rainwater.
For the cracking at the bottom of column, it may be the sign of substrate deterioration
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 11 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
or loosing rendering. It should hammer tapping test to identify the developed
defective area.
For the painting peeled off, it is proposed to conduct visual investigation.
3.4 Pro’s and Con’s of investigative technique
Infrared scanning was a common tool to diagnose defects. It can be known as Infrared
thermography which utilizes an infrared imaging camera that can “see” and “measure”
the invisible heat energy that is emitted by the building components and produce
thermal images (called thermograms) that can identify and document a wide variety of
problems that may not be visible to the naked eye. It makes the diagnose easier
because the test can be conducted at a remote location with lease additional assistance
in terms of manpower or tools.
At the infrared scanning test, one important element is that the tested wall should have
adequate heat soak. Otherwise, no significant result can be obtained since the
temperature variety is too little to be determined. Though the thermography shows a
significant thermal difference for an area, cannot be determined as leakage. It is
because all findings should be treated as suspected defective area for further
investigation only.
By the hammer tapping test is a easy approach to identify latent defect for the
cracking wall surface. It involves just an experienced and trained personel belongs
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 12 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
with tapping rod to complete the test. By sound generated by vibration during tapping,
result obtained effectively and immediately after test.
However, hammer tapping test relies on the experience of testing personnel and
sometimes be a subjective judgement. Even though two experienced person may
advise a different interpretation of the sound and lead to a dispute.
Visual inspection was a simple and the easiest approach to identify simple defect. It
requires inspector with fundamental knowledge on building technology or even
though an semi-experienced person. However under visual inspection, only the top
surfaced condition can be observed. It may neglect if any latent defect underlying at
the substrate of the wall or structure.
3.5 Suggested repairs intervention
For the roofing leakage, it should ensure the watertight at all the construction joints
especially the joints facing upward of the roofing system. It is proposed to refill all
sealant to the anchor bolt for fixing the corrugated sheet to the metal frame. Proper
sealant should be selected so that it is suitable to be used outdoor with durable and
anti-UV behavior.
For the cracking repairing at bottom of column, it is suggested to remove all local and
surrounding hallow rendering to identify the de-bonding condition. If the crack
generated simply by poor workmanship or material, proprietary repair mortar is
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 13 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
suggested to make good the render. For those substrate defects identified, it is
recommended to seek structural engineer’s advice to repair the structural substrate.
Proper shoring and temporary support may be involved depending on actual need.
For painting peeled off, loosing paint should be scrapped and removed until the
plastered surface. Appropriated new painting should be selected so that no harm to the
original painting. Painting colour should be carefully chosen to match the existing
one.
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 14 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
4.0 BUILDING TYPE 1: 20th CENTURY
4.1 Description of Property
Stone Houses comprises a row of five continuous units, namely 31 to 35 Hau Wong
Temple New Village was located in Junction Road and at north west of Hau Wong
Temple in Kowloon City.
The Stone House are Chinese style tenement buildings and they were built on the
foundations of “Ho Ka Yuen” which literally means “The Ho Family Garden”
possibly during 1941-1945.
When the Japanese Army invaded Hong Kong in 1941, they had the ruins of Ho Ka
Yuen Housed demolished down to lower courses of bricks just above the foundations.
They divided the Ho Ka Yuen area into some eleven cottage-sites in two rows with a
courtyard between. These cottages thus occupied exactly the same site as the old Ho
Ka Yuen House and part of them formed the Stone Houses. They were mostly
two-storey pitched-roof of timber rafter, purlins and clay tiles with log joists in
Chinese style. Yet, part of those original tiles was replaced with corrugated sheets.
Internal staircase is constructed by timber.
The external load bearing walls and the internal party walls are constructed of granite
blocks, jointed with cement sand mortar and rendered with plaster on the interior.
There are concrete lintels above the door and window openings.
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 15 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
In 1951-1952, Stone Houses were repaired and let to newcomers fleeing the civil war
in China. Due to the urban development of Kowloon City, Stone Houses was cleared
in 2001.
4.2 Common defects and typical locations
There are signs of dampness at the lower portion of some external walls. The dark
colour jointing mortar indicates insufficient damp proof treatment.
In view of signs of serious water leakage to most of the roof soffit and rots on roof
joists, it is anticipated that there are detached and loosen roof tiles with defective
bedding which result in rain penetration and dilapidation of the roof structure.
However, except dampness problem, termite attack was found in timber component
due to high moisture condition.
Spalling concrete with rusty bars exposed at the soffit is found at some reinforced
concrete beams on 1/F.
4.3 Suitable investigative approach for defect
It is effective approach to identify the latent source and pathway of water leakage
pattern by ultrasonic moisture test. It is a kind of moisture detection technique which
the detect pointer not just detect the surface moisture content, but also 25mm, 50mm,
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 16 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
75mm or 100mm inward from surface. We may capture the simulated pattern at each
depth layer hence chase the weak point causing the leakage.
To diagnose the termite attack of roof timber structure, the primary method is the
visual inspection, hammer tapping and even touching by hand. Insect attacks show
normally typical features, such as galleries on or in the wood developed by termites or
holes made by beetles, and so on. In the case, live adult insects, pupae, larvae or eggs
are found, the insect attack can be judged as progressive.
For the spalling concrete at interior, it may be the sign of substrate deterioration or
loosing rendering. It should hammer tapping test to identify the developed defective
area.
3.4 Pro’s and Con’s of investigative technique
Before ultrasonic moisture test, a pre-determined and evenly distributed grid line (or
marked as dot) will be marked on the wall. Each reading coming from moisture detect
pointer in different depth would be input to the computer to generate a comprehensive
simulated the water pattern for accurate judgement for leakage point. However, the
process is very time-consuming and costly.
Visual inspection for termite attack is easy, direct and without involvement of special
equipment. However, the result is very depending on the experience and knowledge
of inspector and moderate risk on accuracy by human error. The judgement, should
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 17 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
also include whether the timber degradation is progressive or not. It is very important
but sometimes hard to be classified.
However, hammer tapping test relies on the experience of testing personnel and
sometimes be a subjective judgement. Even though two experienced person may
advise a different interpretation of the sound and lead to a dispute.
4.5 Suggested repairs intervention
For the dampness of wall , it should ensure the watertight from the exterior rendering
with least gaps between roofing system and window frames. It is proposed to
re-render by proprietary waterproofing render instead of ordinary cement/sand render
to enhance durability with waterproof behavior.
To mitigate the termite attack and maintain stability of the structure, it is suggested to
employ professional pest control contractor to apply control method to the defective
area. It is aim to mitigate the root cause to prevent termite attack spread for further
damage. Periodic inspection is needed to continuously monitor the development of
termite. After the termite mitigation, strengthening action may be taken and seek
structural engineer’s advice is recommended. The termite mitigation is just a passive
action to control the growth of termite. It is most important to cure completely for
moisture accumulation such as leakage problem and humidity control.
For the cracking repairing soffit of 1/F decking, it is suggested to remove all local and
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 18 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
surrounding loosen concrete. De-rusting is an important process to avoid degrading of
substrate. Proprietary repair mortar is suggested to make good the substrate. For those
serious structural damage, it is recommended to seek structural engineer’s advice to
strengthen the structure. Proper shoring and temporary support may be involved
depending on actual need.
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 19 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
5.0 CONCLUSION AND RECOMMENDATIONS
5.1 Conclusion
3 different architectural period properties namely Gatehouse of Nga Tsin Wai Village,
St. Joseph’s Chapel and Stone Houses are selected and intended to purchase. Brief of
properties’ historical background, architectural features, building material and
decorative elements are assessed and described for general reviewing.
Defects are identified for those building. Leakage and damping problem are most
commonly found from those properties. They appears mainly at the roof structure and
external wall. Secondly, spalling concrete and loosen plaster are also the similar
symptom from those 3 different architectural period of building.
Destructive and non-destructive tests are discussed. Among them, it is commonly and
primarily to conduct visual inspection since its quick and inexpensive approach to
identify the defects which is an important approach for universal condition required
different skill and knowledge of inspector. Ultrasonic moisture test and infrared
scanning are proposed for detection of leakage and seepage problem. In various
situation, Pros and Cons behind each approach discussed and concluded.
The simplest and effective repair method proposed for those properties. or those
serious structural damage, it is recommended to seek structural engineer’s advice to
strengthen the structure. Proper shoring and temporary support may be involved
depending on actual need.
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 20 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
This report revealed the defect and repairing necessities for the selected properties. It
form a basic overview and help to adopt resolution for future investment.
5.2 Recommendations
Selected buildings will be discussed for investment below:
Gatehouse of Nga Tsin Wai Village
It is the significant building for the village with functional background in security. It
situated at the urban area of San Po Kong leads to easy accessible from public.
However the usable area of it limited the reuse and redevelopment of this property. It
seems use as exhibition centre may be the only way for further consideration. The
profitability is low and potential maintenance cost for significant structural crack is
high. Therefore, it is not recommended for investment.
St. Joseph’s Chapel
The Italian Romanesque style church and maintain degree of religious function till
now although most local villagers moved out. It is large usable area and it is very
suitable for exhibition, a convention and variety possible proposes. And it has the
potential to be redeveloped to incorporate to the surrounding open space. However, it
situated at Yim Tin Tsai Island of Sai Kung makes tourist, public, occupants difficult
to reach and high maintenance cost. Which limit the revenue to be made and
profitability is impeded. One thing important that, when approaching to
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 21 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
redevelopment, change of use should be formal applied for consent from various
government departments. It may also be opposed when in open counselling by local
power and lead to abortive project. Therefore, it is not recommended for investment.
Stone Houses
It is the traditional tenant houses after War II. By the condition surveyed, it is no
renovation work carried out for several decades. It used to spend much to recondition
the building due to the large usable area. The property abutted centre zone of
Kowloon City and served by various traffic service to most places of Kowloon
peninsular. The property provides the largest usable floor area by comparing to the
others, it is vital and fulfilling the desire when to be developed into commercial
purpose without catering the time-consuming Gloss Floor Area (GFA) application.
Prompt development will lead to early return for the investor. The property also be
possible to be converted into highly profitable columbarium as it is very close to the
Hau Wong Temple and cemetery nearby to meet the rising demand of it in Hong
Kong in recent decade. Local power’s obstruction will be less since its superior
strategic location. Field study, educational, visitor center, etc. are always to be
permitted to be redeveloped which are also beneficial for development varieties.
Therefore, it is recommended for investment.
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 22 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
6.0 PERSONAL REFLECTION
It is very interesting assignment for me to act as a property redevelopment investor
point of view to handle a building surveying project. It is not be experienced for me
along as I was in building surveying field for several years.
I thought it is not very difficult for me at the beginning of the assignment because I
always familiarize to conduct building surveying to the buildings until I have fallen
into dilemma when conducting survey to historical buildings. In the historical
building, they are so much difference to what I saw in building maintenance point of
view no matter the background information retrieving, building structure, material use,
roofing system, etc. aspects. Especially for timber structure, I could not conduct any
inspection and propose maintenance work while it is really my first touch on these
issues. I was confused in writing on such. Therefore I spent much time to study the
topics relating biodegrading research.
The other difficulty at this assignment is to conduct the visit to those buildings
especially the St. Joseph’s Chapel is located at the off-shore island. I can only reach it
by joining local tour since timetable of ferry is not convenient for me. Fortunately, by
the local tour, I captured much valuable historical story of the island which leading
the chapel to be exclusive from all another in Hong Kong or even in China. It is the
extra benefit of this assignment and made me more and more interesting on the
research.
For proposing the maintenance scheme, it is so quite difference from those work to be
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 23 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
conducted to typical modern buildings which always be reinforced concrete structure
in absence of conservative background. Extra-care and more detail should be
corporate during judgement to avoid the downgraded from original building and
historical characteristics. On the other hand, I needed to take cost into the account
during proposing repairing intervention when to fulfilling the investor’s characters. It
required me to incorporate value management technique to cater the problem.
Finally, for investment issue, it is not as simply as expenditure and profit analysis that
I thought it before. Revitalization of historical building is the key element when to
make the property be unique and operational in Hong Kong. I didn’t direct the
investment into eating place, place of entertainment, etc. but think more in-depth
demand from current society. I started to retrieve the records and study from several
revitalization projects in Hong Kong such as Mallory Street Revitalization, Lui Sang
Chun Revitalization, etc. to endeavor the elements of difference apart from them. So
that it may make the project more famous and profitable in Hong Kong. Investor may
feel comfortable and easier to accept my idea and recommendations.
In this interesting and challengeable assignment, it help me wider vision to the
building surveying technology and sophisticate equipment to help the diagnosis. And
that provides a great lesson to learn for me. It also leads me to think deeper on value
and return behind the building maintenance or revitalization project. I did grateful for
all challenges brought me in this assignment.
< 20 pages excluding cover, content pages and reference page>
HERIOT WATT UNIVERSITY School of the Built Environment – MSc/PgDip in Construction Management & Surveying
Module: D31BX Building and Contextual Investigation
P. 24 / 24 Student: Mak Chi Man (H00118235) Assessment: 2012 (Assignment2)
7.0 REFERENCE
1. Centre for Architectural Heritage Research of the Chinese University of Hong
Kong, (2009), Historical cum Social Study on Kowloon City district in connection
with Kai Tak Area P.166-175, P.212-215;
2. Centre for Architectural Heritage Research of the Chinese University of Hong
Kong, (2011), Heritage Impact Assessment for Revitalization of the Stone Houses
at Junction Road Kowloon City into Stone Houses Family Garden P.31-35;
3. Revitalising Historic Buildings Through Partnership Scheme Secretariat, (2009),
Revitalising Historic Buildings Through Partnership Scheme – Stone Houses –
Resource Tookit P.8-13;
4. The HKU Scholars Hub, (2004), From salt pan to resort plan : heritage
conservation for the Island of Yim Tin Tsai, Sai Kung
http://hdl.handle.net/10722/40003 accessed 26 April 2012;
5. Antiquities and Monuments Office, Historic Building Appraisal – No. 31-35 Hau
Wong Temple New Village, Kowloon City, items 949;
6. Courtesy of Survey and Mapping Office, Lands Department, Hong Kong SAR
Government, survey sheet no.: CXXXVII-NE-6;
7. Chu Wai Tak 朱維德, Xhianjiang jiumao <香江舊貌> [The Old Scenery of
Hong Kong], Hong Kong, Cosmos Books Ltd., 1993;
8. Sai Kung District Board (ed.), <西貢風貌> [Scenes of Sai Kung], Hong Kong:
Sai Kung District Board, 1996;
9. Yoshihisa Fujii et. al., (2010), Characteristics and diagnosing technology of
biodegradation in wooden historical buildings A case study on Amida-do in
Higashi Hongan-ji Temple in Kyoto.