86
Catalog YMI130-EN Precision Making All Products Guide Vol.5 www.nbn.at

All Products Guide

Embed Size (px)

Citation preview

Catalog YMI130-EN

Precision Making

All ProductsGuide

Vol.5

www.nbn.at

new

new

new

ScopeCorder

DL850E/DL850EV

High-Speed Data Acquisition Unit

SL1000

Mixed Signal

Oscilloscopes

DLM2000 Series

Mixed Signal Oscilloscopes

DLM4000 Series

Main Products Line up

Oscilloscopes Digital Power Analyzer

Generators, Sources, Manometers etc. Optical Measuring Instruments

Precision Power Analyzer

WT3000E

Power Analyzer

WT500

Digital Power Meters

WT300E Series

Precision Power Analyzer

WT1800

Precision Power Scope

PX8000

1G/10G Ethernet Tester

AQ1300 Series

DC Voltage /

Current Source

GS200

Optical Spectrum

Analyzer

AQ6370 Series

Optical Time Domain

Reflectmeter

AQ7280

Optical Loss Test Set

AQ1100

Multi Field Tester

OTDR

AQ1200 Series

Multi Application Test

System

AQ2200 Series

AQ2170

Series

Optical Wavelength Meter

AQ6150 Series

AQ2180

Series

AQ4280

Series

Handy size

Optical Power Meter

/ Light Source

AC Voltage

Current Standard

2558A

Precision DC

Calibrator

2553A

Precision DC

Calibrator

2560A

new

new

Calibrator

Digital Multimeter Insulation Tester

Illuminance Meter

Meters ProductsThermometer Clamp-on Power Meter

Clamp-on TesterEarth Tester

Precision Measuring Instruments

CA450

CW10CW500

732 Series

CL420

3213A Series

EY200510 Series

TM20 TX10 Series

279301

205206

CA700 CA150 CA71

TY700 Series TY500 Series

CL150/155

CL220

300

Series

MY40 MY10 Series 2406E Series

276910

201314 204102

73101

The Yokogawa website offers

not only product and technical

information but also campaign

information, user registration,

document download, free

software download, e-mail

news subscription, catalog

request, price inquiry, and lots

of other content.

Internet Website

http://tmi.yokogawa.com

CA310 CA320 CA330

DC Voltage/ Current Source (GS200) ...........36

Multi Channel Source Measure Unit (GS820) ...37

Source Measure Unit (GS610)......................38

GS Series Accessory Software (765670 Curve Tracer Software for the GS series) .............39

Precision DC Calibrator (2553A) ...................40

AC Voltage Current Standard (2558A) ..........41

Precision DC Calibrator (2560A) ...................42

Digital Multimeter (DM7560) .........................43

Digital Resistance Meter (7556) ...................44

Temperature Measuring Instrument (7563) ...44

Arbitrary/Function Generator (FG400 Series) ...45

Pressure Standard (MC100) .........................46

Manometers (MT210/MT210F/MT220/MT10) ...47

Optical Spectrum Analyzer (AQ6370 Series) ...48

Optical Spectrum Analyzer (AQ6370D) ........49

Optical Spectrum Analyzer (AQ6375B/AQ6376 ) ..................................50

Optical Spectrum Analyzer (AQ6373B) ........51

Optical Wavelength Meter (AQ6150 series) .....52

Multi Application Test System (AQ2200) .......53

Optical Time Domain Reflectmeter (AQ7280) ...54

MFT-OTDR (AQ1200) ...................................55

AQ2170 Optical Power Meter .......................56

AQ2180 Optical Power Meter .......................56

AQ4280 Optical Light Source .......................56

MFT-OLTS (AQ1100).....................................57

MFT-1/10GbE (AQ1300 Series) ....................58

Remote OTDR (AQ7277) ..............................59

ScopeCorder and High-Speed Data Acquisition Unit Selection Guide ....................................6

ScopeCorder (DL850E/DL850EV) ..................8

ScopeCorder Accessories ...................... 10, 11

High-Speed Data Acquisition Unit (SL1000) .... 12

High-Speed Data Acquisition Unit (SL1000 Acquisition Software) ................... 13

Digital and Mixed Signal Oscilloscopes Selection Guide .......................................... 14

Common Features of DL/DLM Series ........... 15

Mixed Signal Oscilloscope (DLM2000 Series) ................................ 16, 17

Mixed Signal Oscilloscopes (DLM4000) .... 18, 19

Waveform Measuring (Oscilloscopes Accessories) ......................20

Oscilloscope Application Software (Xviewer/MATLAB tool kit) ..........................21

Digital Power Analyzers Selection Guide ......22

Power Analyzer (WT500) ..............................23

Precision Power Analyzer (WT3000E) ....24, 25

High Performance Power Analyzer (WT1800) .............................................26, 27

Digital Power Meters (WT300E) .............28, 29

Precision Power Scope (PX8000) ...........30, 31

AC/DC Current Sensor (CT60/CT200/CT1000) ...............................32

Current Probe (751552) ................................32

Current Sensor Unit (751522 / 751524) ........32

WT Series Accessory Software (760122 and Power Consumption Measurement Software) ...........33

WT Series Accessory Software (761922 IEC regulation software) ...............34

Digital Power Analyzers Accessories List (Accessories List) .......................................35

[Generators, Sources, Manometers etc.] P. 36 ~ P. 47

[Optical Measuring Instruments] P. 48 ~ P. 59

[Oscilloscopes] P. 6 ~ P. 21

[Digital Power Analyzers] P. 22 ~ P. 35

Contents

Osc

illos

cope

sD

igita

l Pow

erA

naly

zers

Gen

erat

ors,

Sou

rces

,M

anom

eter

s et

c.

Optic

al M

easu

ring

Inst

rum

ents

Cal

ibra

tor

Cla

mp-

onP

ower

Met

erD

igita

l Mul

timet

erC

lam

p-on

Tes

ter

Insu

latio

n Tes

ter

Ther

mom

eter

Eart

h Tes

ter,

Oth

er P

rodu

cts

Pre

cisi

onM

easu

ring

Inst

rum

ents

Met

ers

Pro

duct

s

[Calibrator]CA700, CA150, CA51/CA71, CA310, CA320, CA330, CA310, CA320, CA330, CA450, CW500

P. 60 ~ P. 65

[Clamp-on Power Meter]CW10

P. 66

[Digital Multimeter]TY700 Series, TY500 Series, 732 Series, 73101, 96095

P. 68 ~ P. 71

[Clamp-on Tester]CL100 Series, CL200 Series, 30031A/30032A, CL300 Series, CL400 Series

P. 72 ~ P. 73

[Insulation Tester]MY40, 2406E Series, MY10 Series, 3213A Series

P. 74 ~ P. 77

[Earth Tester, Other Products]EY200, 322610, 510 Series

P. 78

[Thermometer]TM20, TX10 Series

P. 79

[Precision Measuring Instruments]2792A Series, 278610/278620, 2769, 279301/279303, 2755

P. 80

[Meters Products]Portable Instruments 2011 to 2053

P. 81

Products with this mark conform to the EMC standards (regulations

on electromagnetic interference) of European Community.

6

Osc

illos

cope

s

Oscilloscopes

They can be used to capture single-shot or infrequently recurring signals.

They can also execute computations on repetitive waveforms, and automatically extract waveform parameters.

Model

Item

DL850E/DL850EV

…P8

High-Speed Data Acquisition Unit SL1000

…P12

Features • Powerful mobile data acquisition recorders• Measure & analyze dynamic behavior of electromechanical systems• Flexible modular inputs for voltage, current, sensors, CAN/LIN bus and SENT.• Trend & Trigger on electrical power calculations (optional)

• Fast Acquisition, Transfer, and Storage• High-Performance Data Acquisition Unit• Easy to use Easy to use Standard Acquisition Software• Max 128 ch Synchronized (16 ch x 8 units) Data files recorded my multiple units, in synchronized mode, are all linked together by a common LINK file, thereby facilitating batch processing.

Max. sampling rate 100 MS/s (*2) 100 MS/s (*2)

Bandwidth 20 MHz (*2) 20 MHz (*2)

Number of analog input channels 128 ch max (when using eight 720220 modules) 16 ch max (when using any 2 ch input module.)

Logic input 128 bits max (when using eight 720230 modules) —

Max. vertical sensitivity (1:1) 100 μV/div (*2) 100 μV/div (*2)

Vertial axis resolution 16 bit (*2) 16 bit (*2)

Max. sweep sensitivity 100 ns/div (*2) 15 ns/div (Zoom display)

Max. record length St’d 250 Mpts (MW) max / 10 Mpts (MW) (16 ch) 50 MW/ch (Single Trigger Mode)

Optional 2 Gpts (GW) max / 100 Mpts (MW) (16 ch) —

Internal media drive St’d SD memory card slot —

Internal HDD Optional Internal 500 GB or external HDD (selectable) Internal 500 GB

Interface St’d USB2.0/ Ethernet (1000BASE-T) USB2.0

Optional GPIB Ethernet (1000BASE-T)

Internal printer 112 mm width (optional) —

Others Optional • 19 types of plug-in modules• IRIG interface• GPS interface• User-defined math function

• Real time math function• Probe power (4-output)• Power math function• DC 12V Power drive (DL850EV only)

• 12 types of plug-in modules• Probe power (4-output)• Without Xviewer• With the Xviewer Math Edition (1 license) (701992-GP01)

Display (TFT LCD) 10.4-inch color XGA (PC-based Acquisition Software)

External dimensions W × H × D (mm) 355 × 259 × 180 319 × 154 × 350

Weight (kg) Approx. 6.5 (*3) Approx. 6.0 (*3)

*1: See each product catalog for more detaled specifications *2: Depends on input module *3: Plug-in modules are not included

Waveform Measuring ScopeCorder and High-Speed Data Acquisition Unit Selection Guide (*1)

7

Osc

illos

cope

s

Oscilloscopes

Compatibility of the plug-in modules with the main units.

Plug-in Module Main Unit

Model Name DL850E DL850EV SL1000

701250 High-speed 10 MS/s 12-Bit Isolation Module available available available

701251 High-speed 1 MS/s 16-Bit Isolation Module available available available

701255 High-speed 10 MS/s 12-Bit non-Isolation Module available available available

701261 Universal Module available available available

701262 Universal Module (with Anti-Aliasing Filter) available available available

701265 Temperature/high-precision voltage Module available available available

701267 High-voltage 100 kS/s 16-Bit Isolation Module (with RMS) available available available

701270 Strain Module (NDIS) available available available

701271 Strain Module (DSUB, Shunt-CAL) available available available

701275 Acceleration/Voltage Module (with Anti-Aliasing Filter) available available available

701281 Frequency Module available available available

720211 High-speed 100 MS/s 12-Bit Isolation Module available available available

720220 16 CH Voltage Input Module available available NA

720221 16 CH Temperature/Voltage Input Module available available NA

720230 Logic Input Module available available NA

720240 CAN Bus Monitor Module NA available NA

720241 CAN & LIN Bus Monitor Module NA available NA

720243 SENT Monitor Module NA available NA

720254 4 CH 1 MS/s 16-Bit Isolation Module available available NA

* Probes are not included with any modules.

* Up to four CAN Bus Monitor Modules (720240), CAN & LIN Bus Monitor Modules (720241) or SENT Monitor Module (720243) in total can be used on a single

main unit. For the CAN Bus Monitor Modules (720240) and CAN & LIN Bus Monitor Modules (720241), up to two in total can be used on a single main unit.

These modules are available for the DL850EV only.

* The use of a 720221 module always requires the External Scanner Box (model 701953).

InputModel

No.Sample rate Resolution Bandwidth

Number ofchannels

IsolationMaximum

input voltage(DC+ACpeak)

DC accuracy Note

AnalogVoltage

720211*9 100 MS/s 12-Bit 20 MHz 2 Isolated1000 V*2 200 V*3

±0.5% High speed · High voltage · Isolated

701250*5 10 MS/s 12-Bit 3 MHz 2 Isolated600 V*2 200 V*3

±0.5% high noise immunity

701251 1 MS/s 16-Bit 300 kHz 2 Isolated600 V*2 140 V*3

±0.25%High sensitivity range (1 mV/div), low noise (±100 μVtyp.), and high noise immunity

720254 1 MS/s 16-Bit 300 kHz 4 Isolated600 V*2 200 V*3

±0.25%4 CH BNC input low noise, high noise immunity

701255*5 10 MS/s 12-Bit 3 MHz 2 Non-Isolated600 V*4 200 V*3

±0.5% non-isolation version of model 701250

701267 100 kS/s 16-Bit 40 kHz 2 Isolated 850 V*10 ±0.25% with RMS, and high noise immunity

720220 200 kS/s 16-Bit 5 kHz 16Isolated

(GND-terminal)non-isolated (CH-CH)

42 V*3 ±0.3% 16 CH voltage measurement (Scan-type)

Analog Voltage

& Tempera-

ture

701261100 kS/s (Voltage),

500 S/s (Temperature)16-Bit (Voltage),

0.1°C (Temperature)40 kHz (Voltage),

100 Hz (Temperature)2 Isolated 42 V

±0.25% (Voltage)

thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel)

701262100 kS/s (Voltage),

500 S/s (Temperature)16-Bit (Voltage),

0.1°C (Temperature)40 kHz (Voltage),

100 Hz (Temperature)2 Isolated 42 V

±0.25% (Voltage)

thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), with AAF

701265500 S/s (Voltage),

500 S/s (Temperature)16-Bit (Voltage),

0.1°C (Temperature)100 Hz 2 Isolated 42 V

±0.08 (Voltage)

thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), high sensitivity range (0.1 mV/div), and low noise (±4 μVtyp.)

720221*8 10 S/s 16-Bit 600 Hz 16 Isolated 42 V±0.15%

(Voltage)

16-CH voltage or temperature measure-ment (scan method)Thermocouple (K, E, J, T, L, U, N, R, S, B, W, Au-Fe-chromel)

Strain

701270 100 kS/s 16-Bit 20 kHz 2 Isolated 10 V ±0.5% (Strain)Supports strain NDIS, 2, 5, 10 V built-in bridge power supply

701271 100 kS/s 16-Bit 20 kHz 2 Isolated 10 V ±0.5% (Strain)Supports strain DSUB, 2, 5, 10 V built-in bridge power supply, and shunt CAL

Analog Voltage,

Acceleration701275 100 kS/s 16-Bit 40 kHz 2 Isolated 42 V

±0.25% (Voltage)±0.5%

(Acceleration)

built-in anti-aliasing filter, Supports built-in amp type acceleration sensors (4 mA/22 V)

Frequency 701281 1 MS/s 16-Bit resolution 625 ps 2 Isolated420 V*2

42 V*3

±0.1% (Frequency)

Measurement frequency of 0.01 Hz to 500 kHz, Measured parameters (frequency, rpm, period, duty, power supply frequency, distance, speed)

Logic 720230 10 MS/s — —8-bit × 2

portsnon-isolated

depend on logic probe

used.—

(8-bit/port) × 2, compatible with four-type of logic probe (sold separately)

CAN 720240 100 kS/s — —(60signals × 2)

portIsolated 10 V —

CAN Data of max. 32-bit allowableIt is available for DL850EV only. Max. two (2) modules can be installed in a main unit.*6 *7

CAN, LIN 720241 100 kS/s — —(60signals × 2)

portIsolated

10 V (CAN port)18 V (LIN port)

—CAN port × 1, LIN port × 1Available for DL850EV only, up to 2 modules*6 *7

SENT 720243 100 kS/s — —11 data × 2

portsIsolated 42 V —

Supported protocol: SAE J2716. It is available for DL850EV only. Max. four (4) modules can be installed in a main unit.*6 *7

*1: Probes are not included with any modules. *2: In combination with 700929, 702902 or 701947 probe. *3: Direct input *4: In combination with 10:1 probe model 701940

*5: Some of the models 701250/701255 shipped on or before July, 2007 may require factory rework. *6: Any other modules can be installed in the remaining slots.

*7: Up to four CAN Bus Monitor Modules (720240), CAN & LIN Bus Monitor Modules (720241) or SENT Monitor Module (720243) in total can be used on a single main unit. For the CAN Bus Monitor Modules (720240) and CAN & LIN Bus

Monitor Modules (720241), up to two in total can be used on a single main unit. *8: The 16-CH Scanner Box (701953) is required for measurement.

*9: Class 1 Laser Product, IEC60825-1:2007 *10: In combination with 758933 and 701954.

Plug-in Module Selection Guide*1

8

Osc

illos

cope

s

Oscilloscopes

A ScopeCorder is a powerful portable data acquisition

recorder that can capture and analyze both

transient events and trends up to 200 days. Using

flexible modular inputs it combines the measurements

of electrical and physical (sensor) signals, such as from

CAN, LIN, SENT and is also able to trigger on electrical

power related calculations in real-time.

Flexible Inputs with Built-in Signal ConditioningChoose from up to 19 input modules and gain a thorough insight into any

application by synchronizing the measurement of multiple parameters.

• Voltage and Current

• Sensor Outputs

• Temperature, Vibration

/Acceleration, Strain,

Frequency

• Logic Signals & CAN / LIN

and SENT

Large (2 GPoint) memory offers long duration measure-

ment and two instantaneous zoom locations

– 2 GPoint memory (/M2 option) –Comes standard with 250 MPoints of memory, expandable with 1 or 2 GPoint

options.

Large capacity memory does not only simply provide longer durations of

measurement, but also higher sampling rate at the same measurement time

or multi-channel at the same sampling rate.

Zoom to 2 locations

instantaneously

Zoom to 2 locations

instantaneously

Main screen:

20 days of recording

(2 days/div)

Zoom screen:

1 hour (12 min/div)

&

1 second (100 ms/div)

Up to 2 million times!

Instantly zooms 1

second (100 ms/div) even

when the main screen is

displaying 20 days of

recording (2 days/div)

Long memory does not guarantee

better efficiency if the memory

handling and display engine is slow.

Our faster than ever GIGAZoom 2

Engine instantaneously zooms into

two locations.

Long duration, continuous saving of waveforms

– Hard disk recording (/HD0, /HD1 option) –Measured data can be streamed directly to a built-in 500 GB hard disk (/HD1

option)*1 or through the external HDD interface (/HD0 option)*1. With long

periods of evaluation testing, measurements can be

performed at 100 kS/s on 16 channels simultaneously for 10 hours*2.

*1 The /HD0 and /HD1 options cannot be specified together.*2 It depends on the external hard disk connected when using the /HD0 option.

100 kS/sec

with 16 ch

simultaneously

Powerful data acquisition enables the research of dynamic behavior within your application

DL850EV

DL850E

Max. sampling rate 100 MS/s (720211)(*1)

Frequency bandwidth 20 MHz (720211)(*1)

Number of channels Max. 128 ch,

Number of slots for the plug-in module: 8

Logic input Max. 128 bits

(When using eight 720230 modules)

A/D conversion resolution 16 or 12 bits (1*)

DC accuracy ±(0.5% of 10 div)

(701250 and 701255)(*1)

Time axis setting 100 ns/div to 20-day/div

Time axis accuracy ±0.005%

Max. record length Standard 10 Mpts (MW)/ch, total 250 Mpts

(MW) (with /M2 option)

100 Mpts (MW)/ch, total 2 Gpts (GW)

Channel-to-channel Definable math waveforms 8

calculation function

Automatic measurement Maximum number of measured parameters 32

of waveform parameters

Cycle statistical/historic process Maximum number of cycles 64,000

Maximum number of parameters 64,000

Internal media drive SD memory card slot (standard)

500 GB internal hard drive (option)

External hard drive can be connected (option)

Communication interface USB 2.0 (standard)/1000BASE-T Ethernet (standard)

GP-IB (option)

Built-in printer(option) 112-mm width, A6 thermal printer

Other options IRIG interface

GPS interface

User defined computation

Real time math computation

Power math computation

Four probe power outputs

DC 12 V power drive (DL850EV only)

Display 10.4-inch TFT color LCD monitor

Display resolution 1024 × 768 pixels (XGA)

External dimensions 355 (W) × 259 (H) × 180 (D) mm

(excluding handle and protrusions)

Weight Approx. 6.5 kg to 9 kg (varies depending on

the types and the number of modules used)

(*1): Varies depending on the module.

ScopeCorder DL850E/DL850EV

Overview

Basic Specifications

9

Osc

illos

cope

s

Oscilloscopes

Continuous data recording for durability test and/or

surveillance testIntuitive, user-friendly acquisition software comes standard. Continuous

data recording into a PC Hard Disk Drive(HDD) can be performed by “free-

run mode” with no restriction of recording time and file size. The Wizard

automatically recognizes any connected DL850E and its’ plug-in modules.

Just click the Start button to start measuring right away--no complicated

settings to enter.

DL850E ACQ Software

Ethernet or USB

DL850E (front-end)

PC-Internal

HDD

Time synchronization for accurate measurements

– GPS interface (/C30 option) –A GPS antenna can be directly connected to the DL850E side panel. The

DL850E time clock and the sampling clock can be adjusted accordingly.

GPS satellite

GPS antenna

Note: This option can be provided only for a nation that is not prohibited by the Radio Law.

Trend waveform monitor for power and harmonic param-

eters in real time – /G5 option –Max. 126-type power parameter can be calculated. The calculation

results of these parameters can be displayed in DL850E screen as trend

waveforms in real time. The raw signal waveforms along with calculated

parameters(waveforms) can be displayed as trend waveforms with maximum

data updating rate of 100 kS/s.

Trend waveforms of each orders of harmonics, bar-graphs and vector

displays can be displayed.

[ Power parameter trend display example ] [ Harmonic analysis example ]

Once the “Analysis” key is pressed

on the front panel, the dedicated set-

up menu will appear on the screen

which enables to setup easily.

For example, 6-input(3-voltage and 3-current) waveforms for 2-line, which are

total 12 raw signal waveforms, can be monitored simultaneously along with

max. 126-parameter/1-line (or 54-parameters/2- line) can be calculated.

Inverter Inverter/Motor Testing

3-Voltage and 3-Current

DL850E /G5

3-Voltage and 3-Current

Input

Convert AC to DC signals

Inverter section

Modulate DC signal and convert to any AC signals

Drive circuitConverter section

Motor Torque/rotation sensor

Load

Model Number and Suffix Codes

Models and Suffix Codes

Model Suffix Codes Description

DL850E DL850E main unit, 250 MPts(W) memory*1

DL850EV DL850EV main unit, 250 MPts(W) memory*1

Power Cord

-D UL and CSA standard

-F VDE standard

-R AS standard

-Q BS standard

-H GB standard

-N NBR standard

Languages

-HE English menu and panel

-HJ Japanese menu and panel

-HC Chinese menu and panel

-HK Korean menu and panel

-HG German menu and panel

-HF French menu and panel

-HL Italian menu and panel

-HS Spanish menu and panel

Options

/B5 Built-in printer (112 mm)*5

/DC DC12 V power (10-18 V DC) (can be specified for DL850EV only)*5

/M1 Memory expansion to 1 GPts(W)*2

/M2 Memory expansion to 2 GPts(W)*2

/HD0 External HDD interface*3

/HD1 Internal HDD (500 GB)*3

/C1 GP-IB interface*4

/C20 IRIG and GP-IB interface*4

/C30 GPS interface*4, *7

/G2 User-defined math function

/G3 Real time math function*6

/G5 Power math function (with including Real time math function)*6

/P4 Four probe power outputs

*1: The main unit is not supplied with a plug-in module.

*2, *3, *4, *5, and *6: When selecting these, specify one of them.

*7: The /C30 option can be provided only for a nation that is not prohibited by the Radio Law.

[Example of comparison and verification of a measured signal

and CAN bus signal]

ECU Module Sensor 1 Sensor 2

Physical signal input (analog voltage, command pulse)

1 frame output (CAN only)(Data or remote frame)

CAN bus

Measurement by a module other than the CAN Bus Monitor Module

I/O in CAN Bus Monitor Module

Data frame input

Support for both AC and DC power (/DC option, DL850EV only)

Low power consumption of 60 - 120 VA (typ.)

Low noise compared to using an external inverter

12 V DC (10 – 18 V)

• Can be driven by external DC power

such as the vehicle’s battery

100 V AC (100 – 120 V)

200 V AC (200 – 240 V)

• Can also be driven by AC power.

Note: There is a certain restriction when using the 720240, 720241 and/or 720243 modules together with the /G5 option. Please contact our sales representative.

The ScopeCorder Vehicle Edition is designed for engineers working in the automotive and railway industry.

A common measurement challenge is to combine measurements of electrical signals, physical

performance parameters indicated by sensors, together with CAN bus, LIN bus or SENT data transmitted by

the powertrain management system. A ScopeCorder Vehicle Edition addresses this challenge by combining

the measurement of all signals to provide thorough insight into the dynamic behavior of the

electromechanical system. The result is a considerable time saving compared to other approaches such as

analysis on PC or other software.

VEHICLE EDITION

Enhanced capabilities for vehicle design and development such as CAN, LIN buses and SENT monitoringEnhanced capabilities for vehicle design and development such as CAN, LIN buses and SENT monitoring

10

Osc

illos

cope

s

Oscilloscopes

Waveform Measuring ScopeCorder Accessories

Product Model No. Description*1

Differential Probe 700925DC to 15 MHz, 1/10-1/100 selector switch, max. allowable differential voltage ±500 V (DC + ACpeak)

Differential Probe 700924DC to 100 MHz, 1/100-1/1000 selector switch, max. allowable differential voltage ±1400 V (DC + ACpeak) or 1000 Vrms (1/1000 range)

Current Probe 701917 5 Arms, DC to 50 MHz, High-sensitivity

Current Probe 701933 30 Arms, DC to 50 MHz, supports probe power

Current Probe 701930 150 Arms, DC to 10 MHz, supports probe power

Current Probe 701931 500 Arms, DC to 2 MHz, supports probe power

Current Probe 701932 30 Arms, DC to 100 MHz, supports probe power

Probe Power Supply 701934 Supply (4 outputs), large current output, external probe power

10:1 Probe (for Isolated BNC Input) 700929 1000 Vpk-CAT II

10:1 Probe (wide temperature range, for isolated BNC input)

702902 -40 to +85°C, DC to 60 MHz, 1000 Vpk-CAT II

1:1 Safety BNC Adapter Lead(in combination with followings)

701901 1000 Vrms-CAT II

Safety mini-clip (Hook type) B9852MM 1000 Vrms-CAT III, black

Safety mini-clip (Hook type) B9852MN 1000 Vrms-CAT III, red

Large Alligator-Clips (Dolphin type) 701954 1000 Vrms-CAT II, 1 set each of red and black

Passive Probe (10:1)*2 701940 Non-isolated 600 Vpk

1:1 BNC-Alligator Cable 366926 Non-isolated 42 V or less, 1 m

*1: Actual allowable voltage is the lower of the voltages specified for the main unit, probe and cable.

*2: 42 V is safe when using the 701940 with an isolated type BNC input.

11

Osc

illos

cope

s

Oscilloscopes

Accessories Combinations

Plug on clip701948

Isolation probe700929

/P4, Probe Power 4-output (option)

Probe Power 4-output701934

Frequency Module701281

High-speed 100 MS/s12-Bit Isolation Module720211

High-speed 1 MS/s 16-bit Isolation Module701251

4CH 1 MS/s 16-bit Isolation Module720254

High-speed 10 MS/s 12-bit Isolation Module701250

High-Voltage 100 kS/s16-Bit Isolation Module701267

Logic inputModule720230

16 CH Temp./Voltage Input Module720221

Logic Probe (TTL level/Contact Input)1 m: 7029113 m: 702912

Isolated Logic Probe700987

Scanner Box701953(Provided with a connecting cable)Note: This unit is always required for measurement.

High-speed Logic Probe700986

1:1 Banana-alligator Cable366961

Warning:Connect the probe earth cable to ground (grounding potential) when using these differential probes with isolation modules.

Passive Probe for SL1400/DL750701940

BNC cable1 m: 3669242 m: 366925

BNC-alligator cable366926

±500 V, 15 MHzDifferential Probe700925

±1400 V, 100 MHzDifferential Probe700924

7000 Vpk, 50 MHzDifferential Probe701926

Universal Module701261

Universal Module (with AAF)701262

Temperature/High-precision Voltage Module701265

Shunt Resister for 4-20 mA Measurement250 Ω ± 0.1% : 438920100 Ω ± 0.1% : 438921 10 Ω ± 0.1% : 438922

High-speed 10 MS/s 12-bit Non-isolation Module701255

Acceleration/Voltage Module (with AAF)701275

Strain Module (NDIS)701270

Strain Module (DSUB Shunt-CAL)701271

Bridge Head (NDIS)120 Ω: 701955350 Ω: 701956

Bridge Head (DSUB, Shunt-Cal)120 Ω: 701957350 Ω: 701958

Long Test Clips 701906

Alligator Adapters758929

Fork Terminal Adapters758921

Large Alligator Clips (Dolphin Type)701954

Safety mini clips(Hook Type)B9852MM/B9852MN

Alligator Adapters 758922

1:1 Safety BNC Adapter Lead701901

Isolation probe701947

Current Probe 30 Arms DC-50 MHz701933

Current Probe 150 Arms DC-10 MHz701930

Safety BNC Cable 1 m : 7019023 m : 701903

Current Probe 500 Arms DC-2 MHz701931

Current Probe5 Arms DC-50 MHz701917

Measurement Lead Set758933

10:1 Passive Probe702902

4 mm Conversion AdapterB8099NL/B8099NM

12

Osc

illos

cope

s

Oscilloscopes

High-Speed Data Acquisition Unit SL1000

Unit 0Waveform

file

Unit 1Waveform

file

Unit 2Waveform

file

Unit 1-7Data link

file

Ethernet/USB

SYNCIN

SYNCOUT

Unit 7Waveform

file

Easy to use

– Easy to use Standard Acquisition Software

Max 128 ch Synchronized (16 ch x 8 units)

– Data files recorded by multiple units, in synchronized mode, are all linked

together by a common LINK file, thereby facilitating batch processing.

Using this LINK file, data from all units can be processed and analyzed, as

one, at the same time.

Plug & Play: Auto-recognition of units and modules Input type: Plug-in module (A/D converters built in to each unit)Maximum number of input channels: 16 (One unit operation) 128 (8 units synchronous operation)Maximum sample rate: 100 MS/s on all channelsMeasuring mode: Free Run and TriggeredClock source: Internal and externalMaximum record length (internal memory): In Free Run mode 1 module: 32 MW/ch 2 modules: 16 MW/ch 3 to 4 modules: 8 MW/ch 5 to 8 modules: 4 MW/ch In Single Trigger mode 1 module: 50 MW/ch 2 modules: 25 MW/ch 3 to 4 modules: 10 MW/ch 5 to 8 modules: 5 MW/chMeasuring groups: Up to 4 groups definable with independent sample ratesTrigger mode: Normal, Single, and Single(N)Trigger source: Input channel, External, LINE , TimeRecord conditions: For Free Run mode Immediate, abs. time, time divided, alarm, and external trigger For Trigger mode Each triggerInternal hard disk: 500 GB (with the /HD1 option)Maximum real-time hard disk recording speed: Internal hard disk 1.6 MS/s (= 200 kS/s × 8 ch = 100 kS/s × 16 ch)

Sampling rate

Number of Measuring Channels

2 ch 4 ch 8 ch 16 ch

100 MS/s 0.5 0.25 0.1 0.05

50 MS/s 1 0.5 0.2 0.1

10 MS/s 2.5 1.25 0.5 0.25

1 MS/s 25 12.5 5 2.5

500 kS/s 100 50 20 10

200 kS/s 250 125 50 25

1 kS/s 50000 25000 10000 5000

Fast Acquisition

– Up to 100 MS/s on all channels (10 ns sampling interval)

– Supports parallel testing: Perform measurements with up to four simulta-

neously independent sample rates

Fast Transfer and Storage

– Stream data to PC via high speed USB 2.0 or 1000BASE-T Gigabit Ether-

net

– Stream data to a PC hard disk or the SL1000's internal hard disk in real

time (at speeds of 1.6 MS/s = 100 kS/s × 16 ch)1

– Maximum 8 synchronized units

1: Speed depends on PC performance and measuring conditions.

Stand-Alone Recording

– Normally, SL1000 is controlled by PCs. However, SL1000 can record data

even without PCs (/HD1 option is required).

This stand-alone recording function is useful for the measurement in the

severe environment.

Basic Specifications

Model Number and Suffix Codes

Maximum measuring time (unit: sec) at Single triggered measurement

Features

Fast Acquisition, Transfer, and Storage

High-Performance Data Acquisition Unit

SL1000

Model Suffix Code Description

720120SL1000 High-Speed Data Acquisition Unit*1

Including Xviewer Standard Edition (1 license)(701992-SP01)

Power cord

-D UL and CSA standard

-F VDE standard

-R AS standard

-Q BS standard

-H GB standard (Complied with CCC)

Options

/HD1 Internal 500 GB HDD

/C10 Ethernet Interface

/P4 Probe power (4-output)

/XV0 Without Xviewer

/XV1 With the Xviewer Math Edition (1 license)(701992-GP01)

*1: Plug-in modules and PC not included with the SL1000.

Model Description

720211 High-speed 100 MS/s 12-Bit Isolation Module (2 ch)

701250 High-speed 10 MS/s 12-Bit Isolation Module (2 ch)

701251 High-speed 1 MS/s 16-Bit Isolation Module (2 ch)

701255 High-speed 10 MS/s 12-Bit non-Isolation Module (2 ch)

701267 High-voltage 100 kS/s 16-Bit Isolation Module (with RMS, 2 ch)

701261 Universal Module (2 ch)

701262 Universal Module (with Anti-Aliasing Fileter, 2 ch)

701265 Temparature / High-precision voltage Module (2 ch)

701275 Acceleration / Volatage Module (with Anti-Aliasing Filter 2 ch)

701270 Strain Module (NDIS, 2 ch)

701271 Strain Module (DSUB, Shunt-CAL, 2 ch)

701281 Frequency Module

Product Model No. Description

Synchronized connection cable720901-01 For SL1000 (1 m)

720901-02 For SL1000 (3 m)

Rack mounting kit751541-E4 EIA standard

751541-J4 JIS standard

13

Osc

illos

cope

s

Oscilloscopes

High-Speed Data Acquisition Unit SL1000 Acquisition Software

Setup Wizard

Startmeasurement

Main Specifications of Acquisition Software

Accumulating Waveforms

Displaying X-Y Waveforms

Setting Marks

Setup Wizard Makes It Easy

The four screens of the Setup Wizard guide you easily through detailed settings

for configuring the system, measuring, saving, and displaying. You can save and

recall your settings at any time.

Plug and Play Auto-recognition of units and modulesMeasurement modes Free Run and TriggeredACQ modes Normal, envelope, and box averageClock sources Internal and externalMeasurement groups Up to 4 groups definable with independent sample ratesTrigger modes Normal, single, and single(N)Trigger sources CH1-CH16, LINE, Time, and ExternalOther trigger functions Combination trigger, hold-off, pretriggers, and trigger delaySave conditions Manual operation, or based on time, or alarmsOther save functions Manual save (file division), specify no. of saves, save all data

in memory, and save simultaneously to PC’s hard disk and SL1000’s internal hard disk (with /HD1 option)

Save format Binary data file (original, *.wdf)Waveform data Binary data file(s) can be converted to ASCIIconversion (Xviewer) (*.csv) or Excel (*.xls) formatMaximum speed for saving in real time PC hard disk 1.6 MS/s (= 100 kS/s × 16 channels)*1

Waveform monitor Trend display (displays measured waveforms of different sample rates simultaneously)*2, and instantaneous value displays (digital, bar graph, meter, and thermometer)

X-Y display X-axis channel settings, selection of main or zoomed waveform (in Triggered mode), and selection of the number of data points to draw (2 K, 10 K, 100 K)

Mark display (Free run mode) Setting of marks (up to 128 marks, each mark can display up to 16 characters), display color setting, mark editing, deletion of marks, mark list, collectively saving mark data with the same file name as the waveform data, and loading mark data into Xviewer.

Accumulation display Accumulates T-Y and X-Y waveformsSnapshot Waveform that is currently being displayed can be retained on

the screen as a snapshot waveform. Display color setting and snapshot waveform deletion

Display groups Up to 4 display groupsOther display functions History waveform, arbitrary axis divisions, and horizontal axis

scaling + specifiable units (external clock)Waveform analysis Cursor and parameter measurement*3

Offline waveform computation (with /XV1 option) Max. Number of displayed waveforms (CHs)

10 waveforms (Math1 to Math 10) Operations +, -, ×, /, trigonometry, differentiation/integration, FFT, and othersAlarms Channel (alarm display and alarm history analysis)*4, system

alarm, and alarm outputGO/NO-GO determination*3 Waveform parameter judgment and judgment outputSystem requirements OS Windows XP (SP2 or later) /Windows 7 (32 bit /64 bit) /

Windows 8 (32 bit /64 bit) CPU Core 2 Duo 2 GHz or better Memory 1 GB or more Hard disk 500 MB or more of free space (40 GB or more when using the

auto-save function) Communication interfaces USB 2.0/Ethernet 1000BASE-T (with /C10 option) Display XGA or better, Color: 65536 colors or better Other CD-ROM drive and mouse

*1: Typical values. Actual values depend on PC performance and measurement conditions.*2: When the measurement mode is Free Run, the trigger mode is Single(N), and the number of

measurements is Infinite, there may be a limit to the number of channels that can be trend-displayed during measurement.

*3: Triggered measurement*4: Free Run measurement

For details on 701992 Xviewer, see page 21.

Control Buttons––Just Like Your DVD Remote

Measurement and saving can be started and stopped using the same familiar

buttons found on a DVD remote control. Start using the instrument on the same

day you receive it, with absolutely no programming required.

You can enter comments in the Mark area when monitoring over long periods of

time (Free Run mode).

You can view both T-Y waveform display and X-Y waveform display. Using its fast

update feature, you can evaluate data quickly and easily.

Using the accumulation feature, you easily view unevenness of repetitive data.

Intuitive OperationEasy to Use

14

Osc

illos

cope

s

Oscilloscopes

The DLM series digital oscilloscopes

have high-speed sampling and a

wide range of bandwidths that

can be utilized for design and

development of electronic devices.

They can also execute computations

on repetitive waveforms and

automatically extract waveform

parameters.

The DLM series offers an extensive

selection of digital oscilloscopes

with large-capacity memories,

powerful triggering functions,

unique History Memory function

and built-in printers. It also can save

and load data to and from internal or

external media.

ModelItem

DLM2000 Series ...P16 DLM4000 Series ...P18

Features Compact & lightweight

Analog 4 ch/Analog 3 ch+Logic 8bits

Long memory

UART,I2C,SPI,CAN,CAN FD,LIN,FlexRay and SENT bus

analysis functions

Power supply analysis functions

Analog 8 ch+Logic 16bits/Analog 7 ch+Logic 24bits

Long memory

UART,I2C,SPI,CAN,CAN FD,LIN,FlexRay and SENT bus

analysis functions

Power supply analysis functions

Large display

Max. sampling rate 2.5 GS/s 2.5 GS/s

Bandwidth 500 MHz(*2) 500 MHz(*2)

Number of analog input channelsDLM2022,DLM2032,DLM2052:2

DLM2024,DLM2034,DLM2054:48

Logic input St’d DLM2024, DLM2034,

DLM2054: St’d 8 bits

8 bits

Optional 24 bits

Max. vertical sensitivity (1:1) 2 mV/div 2 mV/div

Vertial axis resolution 8 bits 8 bits

Max. sweep sensitivity 1 ns/div 1 ns/div

Max. record lengthSt’d 62.5 Mpoints 12.5 Mpoints

Optional 250 Mpoints 250 Mpoints

Internal storageSt’d Approx. 300 MB Approx. 1.8 GB

Optional Approx. 7.2 GB Approx. 7.2 GB

InterfaceSt’d USB USB/Ethernet

Optional Ethernet/GP-IB GP-IB

Built-in printer Optional 112 mm width 112 mm width

Others Optional I2C bus analysis

SPI bus analysis

CAN, CAN FD and LIN bus analysis

FlexRay bus analysis

SENT bus analysis

UART bus analysis

Probe Power

Power supply analysis functions

User-defined math functions

I2C bus analysis

SPI bus analysis

CAN, CAN FD and LIN bus analysis

FlexRay bus analysis

SENT bus analysis

UART bus analysis

Probe Power

Power Supply analysis functions

User-defined math functions

Display (TFT LCD) 8.4-inch color, XGA 12.1-inch color XGA

External dimensions

W × H × D (mm)226 × 293 × 193 426 × 266 × 178

Weight (kg) Approx. 4.2 Approx. 6.6

*1: See each product catalog for more detaled specifications.

*2: Depends on model

Waveform Measuring Digital and Mixed Signal Oscilloscopes Selection Guide

15

Osc

illos

cope

s

Oscilloscopes

This feature meets the need to measure as many signals

as possible simultaneously with one oscilloscope.

DLM2000/DLM4000 series

The DLM2000 (DLM4000) series usually functions as 4 (8)

channel analog, and is able to switch CH 4 (8) of analog input to

8-bit logic quickly whenever the need arises.

Common Features of DL/DLM Series

When the sample rate is increased with oscilloscopes

with less memory, the observation time may run out.

All of Yokogawa’s oscilloscope models are equipped

with large capacity memory. For example, the DLM2000/

DLM4000 offers long memory of up to 250 Mpoints for

measurement.

Even at a fast sample rate of 1.25 GS/s, waveforms for 0.2

seconds can be captured.

The history memory function that divides the long

memory can redisplay past waveforms that have

disappeared from the screen.

With the DLM2000/DLM4000 series, up to 50,000

previously captured waveforms can be saved in

memory.

Since a large amount of data is also processed at high

speed by dedicated hardware, the long memory can be

used comfortably without sacrificing response time.

To facilitate the use of a PC, various interfaces such

as USB, Ethernet, and GP-IB are available as standard

or an option.

In addition, various software is available to support

remote control, file transfer, and data processing

on a PC.

USB memory and peripheral devices, such as keyboard

and mouse, can be connected, and connecting to a PC

using a USB cable enables it to be used as the external

storage of the PC.

With a small built-in printer, measured waveforms can

be printed to paper immediately.

• A variety of triggers capture complex waveforms

• Real time digital filter with optimum noise reduction

• Zooms into two different points simultaneously

• Automated measurement of waveform parameters and

statistical processing function

• Frequency analysis by FFT computation

• Go/No-Go function and action on trigger function to

determine abnormal waveforms and save files.

• Analysis functions for specific applications, such as

serial bus analysis and power supply analysis

LogicAnalog

DLM4000 series

Up to 8 channels of analog signals can be measured.

ScopeCorder Series is available for customers that

require more channels for measurement (see page 6).

The DL850E supports up to 128 channel measurement.

Multichannel

Long Memory

Connection with a PC

Built-in Printer

A Variety of Triggers and Analysis Functions

USB memory USB keyboard

1000BASE-T/100BASE-TXcompliant adapters (hubs and routers)

Sends waveform, screen, and settings dataRemote control

Sends waveform, screen, and settings data

Remote control

Mail transmission (GO/NO-GO action)

USB (standard on rear panel)

Internal storage (/C9 option)

Ethernet(/C10 and /C11 options)

Waveform history

16

Osc

illos

cope

s

Oscilloscopes

Easy-to-Use, Portrait Body, Compact, and Large Screen Personal Mixed Signal Oscilloscope Offers Convenience with Logic Inputs

Easy-to-Use & Easy-to-See

Easy to use. Portrait body + large screen makes display easy to see.

We elevated the large (8.4-inch) LCD screen up into the line

of sight. Also, the portrait format saves space on the desk or

test bench. A compact personal oscilloscope designed for easy

viewing and ease of use.

Signal observation on 4 channels or more...

Flexible MSO Input

Four channels is not sufficient to view the functioning of digital

control circuits. The DLM2000 series converts 4 channels of

analog input to 8-bit logic, and functions as a 3 channel analog

+ 8-bit logic MSO (mixed signal oscilloscope).

You can replay waveforms later on, so you'll never miss

an abnormal waveform

History function

With the DLM2000 series, up to 50,000 previously captured

waveforms can be saved in the acquisition memory. With the

History function, you can display just one or all of the previously

captured waveforms (history waveforms) on screen. You can

also perform cursor measurement, computation, and other

operations on history waveforms. Using the History function, you

can analyze rarely-occurring abnormal signals.

DLM2000

Analog Signal input Input channels Analog input DLM20x2: CH1, CH2 DLM20x4: CH1 to CH4 (CH1 to CH3 when using logic input) Input coupling setting AC, DC, DC50 Ω, GND Input impedance Analog input 1 MΩ ±1.0%, approximately 20 pF 50 Ω ±1.0% (VSWR 1.4 or less, DC to 500 MHz) Voltage axis sensitivity 1 MΩ 2 mV/div to 10 V/div (steps of 1-2-5) setting range 50 Ω 2 mV/div to 500 mV/div (steps of 1-2-5) Max. input voltage 1 MΩ 150 Vrms (CAT I) 50 Ω Must not exceed 5 Vrms or 10 Vpeak Frequency characteristics (-3 dB attenuation when inputting a sinewave of amplitude ±3 div)*1*2

DLM202x DLM203x DLM205x 1 MΩ (when using passive probe) 100 mV to 100 V/div DC to 200 MHz DC to 350 MHz DC to 500 MHz 20 mV to 50 mV/div DC to 150 MHz DC to 300 MHz DC to 400 MHz 50 Ω 10 mV to 500 mV/div DC to 200 MHz DC to 350 MHz DC to 500 MHz 2 mV to 5 mV/div DC to 150 MHz DC to 300 MHz DC to 400 MHz Maximum sample rate Real time sampling mode Interleave OFF 1.25 GS/s Interleave ON 2.5 GS/s Repetitive sampling mode 125 GS/s Maximum record length 2 ch model Repeat/Single/Single Interleave: (/M1S) 6.25 M/25 M/62.5 MPoints 4 ch model Repeat/Single/Single Interleave: (/M1) 6.25 M/25 M/62.5 MPoints 4 ch model Repeat/Single/Single Interleave: (/M2) 12.5 M/62.5 M/125 MPoints 4 ch model Repeat/Single/Single Interleave: (/M3) 25 M/125 M/250 MPointsLogic Signal Input (4 ch model only)

Number of inputs 8 bit (excl. 4 ch input and logic input) Maximum toggle frequency*1 Model 701988: 100 MHz Model 701989: 250 MHz Compatible probes 701988, 701989 (8 bit input) (701980, 701981 can also be used) Display 8.4-inch TFT color liquid crystal display 1024 × 768 (XGA)Rated supply voltage 100 to 240 VAC Rated supply frequency 50 Hz/60 Hz Maximum power consumption 170 VA External dimensions 226 (W) × 293 (H) × 193 (D) mm (when

printer cover is closed, excluding protrusions)

Weight Approx.4.2 kg With no optionsOperating temperature range 5°C to 40°C

*1 Measured under standard operating conditions after a 30-minute warm-up followed by calibration. *2 Value in the case of repetitive phenomenon.

Mixed Signal Oscilloscope DLM2000 Series

Basic Specifications

Features

Waveform history

Abnormal signal

Vertical Postion and Scale Knob

Horizontal Postion and

Scale Knob

Trigger Control Keys and Level Knob

Dedicated Zoom Keys

Jog Shuttle and Rotary

Knob

Four-Direction Selector

Button

Select key moves the

cursor up/down/left/right

Logic input connector

17

Osc

illos

cope

s

Oscilloscopes

Model Suffix code Description

710105 Digital Oscilloscope DLM2022 2 ch, 200 MHz

710110*1 Mixed Signal Oscilloscope DLM2024 4 ch, 200 MHz

710115 Digital Oscilloscope DLM2032 2 ch, 350 MHz

710120*1 Mixed Signal Oscilloscope DLM2034 4 ch, 350 MHz

710125 Digital Oscilloscope DLM2052 2 ch, 500 MHz

710130*1 Mixed Signal Oscilloscope DLM2054 4 ch, 500 MHz

Power cord -D UL/CSA standard

-F VDE standard

-Q BS standard

-R AS standard

-H GB standard

-N NBR standard

Language -HE English Menu and Panel

-HC Chinese Menu and Panel

-HK Korean Menu and Panel

-HG German Menu and Panel

-HF French Menu and Panel

-HL Italian Menu and Panel

-HS Spanish Menu and Panel

Option /LN No switchable logic input (4 ch model only)

/B5 Built-in printer

/M1*2 (standard) Standard memory (4 ch model only) During continuous measurement: 6.25 Mpoints; Single mode: 25 Mpoints (when interleave mode ON: 62.5 Mpoints)

/M2*2 Memory expansion (4 ch model only) During continuous measurement: 12.5 Mpoints; Single mode:62.5 Mpoints (when interleave mode ON: 125 Mpoints)

/M3*2 Memory expansion (4 ch model only) During continuous measurement: 25 Mpoints; Single mode: 125 Mpoints (when interleave mode ON: 250 Mpoints)

/M1S (standard) Standard memory (2 ch model only) During continuous measurement: 6.25 Mpoints; Single mode: 25 Mpoints (when interleave mode ON: 62.5 Mpoints)

/P2*3 Probe power for 2 ch models

/P4*3 Probe power for 4 ch models

/C1*4 GP-IB Interface

/C10*4 Ethernet Interface

/C11*4 GP-IB + Ethernet Interface

/C9 Internal storage (7.2 GB)

/G2*5 User defined math (4 ch model only)

/G3*5 Power supply analysis function (4 ch model only)

/G4*5 Power supply analysis function (includes /G2) (4 ch model only)

/F1*6 UART trigger and analysis (4 ch model only)

/F2*6 I2C + SPI trigger and analysis (4 ch model only)

/F3*6 UART + I2C + SPI trigger and analysis (4 ch model only)

/F4*7 CAN + LIN trigger and analysis (4 ch model only)

/F5*7 FlexRay trigger and analysis (4 ch model only)

/F6*7 FlexRay+CAN+LIN trigger and analysis (4 ch model only)

/F7*7 CAN+CAN FD+LIN trigger and analysis (4 ch model only)

/F8*7 FlexRay+CAN+CAN FD+LIN trigger and analysis (4 ch model only)

/F9 SENT analysis (4 ch model only)

/EX22*8 Attach two 701946 probes (For 2 ch, 200 MHz models)

/EX24*8 Attach four 701946 probes (For 4 ch, 200 MHz models)

/EX52*9 Attach two 701946 probes (For 2 ch, 350/500 MHz models)

/EX54*9 Attach four 701946 probes (For 4 ch, 350/500 MHz models)

*1: Logic probes sold separately. Please order the model 701988/701989 accessory logic probes separately. *2: One of these must be selected.*3: Specify this option when using current probes or differential probes that don't support probe interface. *4: Only one of these may be selected at a time.*5: Only one of these may be selected at a time. *6: Only one of these may be selected at a time.*7: Only one of these may be selected at a time.*8: The 701938 probes are not included when this option is specified.*9: The 701939 probes are not included when this option is specified.

Additional Option License for DLM2000*Model Suffix code Description

709810 -G2 User defined math (4 ch model only)

-G3 Power supply analysis function (4 ch model only)

-G4 Power supply analysis function (includes G2) (4 ch model only)

-F1 UART trigger and analysis (4 ch model only)

-F2 I2C + SPI trigger and analysis (4 ch model only)

-F3 UART + I2C + SPI trigger and analysis (4 ch model only)

-F4 CAN + LIN trigger and analysis (4 ch model only)

-F5 FlexRay trigger and analysis (4 ch model only)

-F6 FlexRay + CAN + LIN trigger and analysis (4 ch model only)

-F7 CAN+CAN FD+LIN trigger and analysis (4 ch model only)

-F8 FlexRay+CAN+CAN FD+LIN trigger and analysis (4 ch model only)

-F9 SENT analysis (4 ch model only)

-X1 F4 -> F7/F6 -> F8 (add CAN FD)

*: Separately sold license product (customer-installable).

Analysis Functions

Models and Suffix Codes

Even complex waveforms can be captured

Variety of triggers combining analog and logic inputs

The DLM2000 series comes with a variety of triggers ranging

from an easy and simple Edge trigger through to sophisticated

Enhanced and B triggers. In particular, its ability to freely

combine analog and logic inputs is a great feature of this mixed

signal oscilloscope equipped with a hybrid channel.

FlexRay/UART/CAN/CAN FD/LIN/SENT/I2C/SPI

Serial analysis function options

A wide variety of trigger conditions can be set, such as ID/Data

trigger combinations and combinations of serial bus triggers with

normal edge triggers. Up to four busses with different types and

speeds can be analyzed simultaneously and decode display can

be shown in real time.

Switching loss, power measurement, joule integral, SOA

analysis, and harmonic current based on EN61000-3-2

Power supply analysis option

Utilizing the long memory capability, voltage and current

waveforms over long cycles can be input for computation of

switching loss (V(t) X i(t)). A wide variety of switching loss

analyses are supported, including turn on/off loss calculation,

loss including conduction loss, and loss over long cycles (50

Hz/60 Hz). Automated measurement of power parameters for up

to two pairs of voltage and current waveforms, such as active

power, apparent power, power factor and so on.

Optimum noise reduction

Real time filters and filters based on MATH functions

The DLM2000 series has two types of filters, one real time

processed at the input circuit and one based on MATH functions.

Since the cutoff frequency can also be finely set, these filters are

effective in rejecting unwanted signals and observing only the

desired signals.

Waveform zoom and search functions

Zoom two locations simultaneously, zoom search and history search

Because the DLM2000 series lets you set zoom factors

independently, you can display two zoomed waveforms with

different time axis scales at the same time. Also, using the

search functions, you can search the long memory and history

memory and instantaneously find desired waveforms that meet

the search criteria.

Can check functions with graphical help

Graphical online help

You can view detailed graphical explanations of the oscilloscope's

functions and operations by pressing the “?” key in the lower left

of the screen. This lets you get help on functions and operations

on screen without having to consult the user’s manual.

Edge trigger

Enhanced triggers

B triggers

Edge

Edge OR

Edge (qualified)

State

Pulse width

State width

Serial: (option) FlexRay/CAN/CAN FD/LIN/

SENT/UART/I2C/SPI

: (standard) user-defined

TV: NTSC/PAL/SDTV/HDTV/user-defined

A Delay B

A to B(n)

Dual bus

(combination trigger of 2 serial busses)

18

Osc

illos

cope

s

Oscilloscopes

Yokogawa’s proprietary new enhanced eight channel

oscilloscope comes with a larger display to enable

waveforms to be easily viewed and the latest functions.

• 8 analog channels or 7 analog channels + 8-bit logic input

• Optional 16-bit logic input

• Up to 2.5 GS/s

• 350 MHz or 500 MHz frequency bandwidth

• 12.1-inch large display

• Large memory of up to 250 Mpoints

• Light, slim, and compact design

The world’s first eight analog channel 500 MHz oscilloscope for faster and more advanced power electronics, automobile electronics, and mechatronics development.

Mixed Signal Oscilloscopes DLM4000

DLM4000

CAN / CAN FD / LIN /

FlexRay / SENT

UART / I2C /SPI

Applications

Features

Motor Control and Inverter/IPM Circuit Development

Simultaneous multi-channel measurements are a necessity for the development of control circuits,

Intelligent Power Module (IPM), and inverter electronics, which are the key to more efficient, compact,

and reliable high-performance motors. Up to 8-channel analog waveform measurement of the DLM4000

empowers engineers in this field.

Examples

• Simultaneous measurement of the 3-line voltage and 3-phase current of a 3-phase motor

• Simultaneous measurement of the gate control signals of 6 IGBTs within an inverter

4ch Limitations of 4 ch ScopeWhole-system measurement is impossible due to a lack of analog input channels when, for example, measuring the overall timing of the

control signals, checking an error of the phase-to-phase balance between 3 phases, and simultaneously measuring the I/O signals of a motor

driver IC.

Limitations of Two Synchronized 4 ch Scopes

Eight channel measurement using two trigger-synchronized oscilloscopes is a possible solution but it does not help increase efficiency because

there are various problems. For example, the data is not reliable due to the lack of guarantee of the synchronization of two oscilloscopes.

Double the space is required and they are difficult to carry around. The different design and operations of each of the two oscilloscopes are

cumbersome. The response is slow and handling of the measurement data is tricky.

Automobile ECU and Integrated Mechatronics Device Development

Electronic Control Unit (ECU) and controller I/O signals must be measured simultaneously at high

speed. To meet this requirement, the DLM4000 offers eight analog channels, logic measurement, and

protocol analysis (communication data decoding) functions such as UART (RS232), I2C, SPI, CAN,

CAN FD, LIN, SENT and FlexRay to help speed up the R&D process.

Examples

• Simultaneous measurement of controller I/O signals and serial bus signals

• Measurement of the analog behavior of logic signals and serial bus signals

4ch Limitations of 4 ch + 16-bit MSOECUs, controllers, and driver ICs handle many I/O signals but the 4-channel + 16-bit MSO cannot measure all the signals. Furthermore, it

measures bus communication signals and digital signals using logic input so it cannot measure waveform quality and noise margin. Therefore,

it is difficult to increase stability and reliability.

Recorder Limitations of Memory RecorderA memory recorder is generally suitable for long-time multi-channel measurement, but due to its low sampling rate and slow waveform

update speed, its performance is not adequate for measuring high-speed signals and communication signals of CPUs and FPGAs, or detecting

noise that causes problems or error signals.

8ch

8ch

19

Osc

illos

cope

s

Oscilloscopes

Model Suffix Code Description

DLM4038*1 Mixed Signal Oscilloscope: 8 ch, 350 MHz

DLM4058*1 Mixed Signal Oscilloscope: 8 ch, 500 MHz

Power cord -D UL/CSA standard

-F VDE standard

-Q BS standard

-R AS standard

-H GB standard

-N NBR standard

Language -HE English Message and Panel

-HC Chinese Message and Panel

-HK Korean Message and Panel

-HG German Message and Panel

-HF French Message and Panel

-HL Italian Message and Panel

-HS Spanish Message and Panel

Option /L16 Logic 16-bit

/B5 Built-in printer

/M1*2 Memory expansion

During continuous measurement: 6.25 Mpoints;

Single mode: 25 Mpoints (when interleave mode ON: 62.5 Mpoints)

/M2*2 Memory expansion

During continuous measurement: 12.5 Mpoints;

Single mode: 62.5 Mpoints (when interleave mode ON: 125 Mpoints)

/M3*2 Memory expansion

During continuous measurement: 25 Mpoints;

Single mode: 125 Mpoints (when interleave mode ON: 250 Mpoints)

/P8*3 Eight probe power connectors

/C1 GP-IB Interface

/C8 Internal storage (7.2 GB)

/G2*4 User defined math

/G3*4 Power supply analysis function

/G4*4 Power supply analysis function (includes /G2)

/F1*5 UART trigger and analysis

/F2*5 I2C+SPI trigger and analysis

/F3*5 UART+I2C+SPI trigger and analysis

/F4*6 CAN+LIN trigger and analysis

/F5*6 FlexRay trigger and analysis

/F6*6 FlexRay+CAN+LIN trigger and analysis

/F7*6 CAN+CAN FD+LIN trigger and analysis

/F8*6 FlexRay+CAN+CAN FD+LIN trigger and analysis

/F9 SENT trigger and analysis

/E1*7 Four additional passive probes (8 in total)

/E2*7 Attach four 701946 probes*8

/E3*7 Attach eight 701946 probes*8

*1: Logic probes are not included. Please order the accessory logic probe 701988/701989 sold separately.*2: Only one of these options can be selected at a time. *3: Specify this option when using current probes or differential probes that don't support probe interface.*4: Only one of these options can be selected at a time.*5: Only one of these options can be selected at a time.*6: Only one of these options can be selected at a time.*7: Only one of these options can be selected at a time.*8: The 701939 passive probes are not included when this option is specified.

Additional Option License for DLM4000*Model Suffix code Description

709820 -G2 User defined math-G3 Power supply analysis function-G4 Power supply analysis function (includes G2)-F1 UART trigger and analysis-F2 I2C + SPI trigger and analysis-F3 UART + I2C + SPI trigger and analysis-F4 CAN + LIN trigger and analysis-F5 FlexRay trigger and analysis -F6 FlexRay + CAN + LIN trigger and analysis-F7 CAN + CAN FD + LIN trigger and analysis-F8 FlexRay + CAN + CAN FD + LIN trigger and analysis-F9 SENT trigger and analysis-X1 F4 -> F7/F6 -> F8 (add CAN FD)

*: Separately sold license product (customer-installable).

Models and Suffix CodesSpecifications

Input Channels: 8 analog channels, or 7 analog channels + 8 logic channels (standard)

8 analog channels + 16 logic channels, or 7 analog channels + 24 logic channels (/L16 option)

Analog Input:Frequency bandwidth: 350 MHz (DLM4038) or 500 MHz(DLM4058)Voltage axis sensitivity setting range: 2 mV/div to 10 V/div for 1 MΩ 2 mV/div to 500 m V/div for 50ΩVoltage axis DC accuracy: ±(1.5% of 8 div + offset voltage accuracy)A/D conversion resolution: 8-bitLogic InputMaximum toggle frequency: 100 MHz (701988) or 250 MHz (701989)Probes that can be used: 701988 and 701989 (701980 and 701981)Minimum input voltage: 500 mVp-p (701988) or 300 mVp-p (701989)Input range: ±40 V (701988) Threshold level ±6 V (701989)Maximum non-destructive input voltage: ±40 V (DC + AC peak) or 28 Vrms (701989)Threshold level setting range: ±40 V (701988) or ±6 V (701989)Common SpecificationsMaximum sampling rate Real-time sampling mode: Interleave OFF: 1.25 GS/s Interleave ON: 2.5 GS/s Repetitive sampling mode: 125 GS/sTime axis setting range: 1 ns/div to 500 s/divMaximum record length: Repeat: 1.25 Mpoints, Single: 6.25 Mpoints,

Single Interleave: 12.5 Mpoints (standard) Repeat: 25 Mpoints, Single: 125 Mpoints,

Single Interleave: 250 Mpoints (/M3 option)History memory maximum data: 2,500 (record length 1.25 kPoints; standard) 50,000 (record length 1.25 kPoints; /M3 option)Trigger modes: Auto, Auto Level, Normal, Single, N-SingleTrigger types: Edge, Edge OR, Edge Qualified, State, Pulse

Width, State Width, TV, Serial Bus (I2C/SPI/UART/CAN/CAN FD/LIN/FlexRay/SENT/UserDefine), A Delay B, A to B (N), Dual Bus, Force

Internal storage: 1.8 GB (standard) or 7.2 GB (/C8 option)Interfaces: USB peripheral connection terminal × 2 USB-PC connection terminal × 1 Ethernet (standard), GP-IB (option)Build-in printer: 112 mm wide, monochrome, thermalDisplay: 12.1-inch color TFT LCD 1024 × 768 (XGA)Dimensions: 426 (W) × 266 (H) × 178 (D) mmWeight: approx. 6.6 kg (with no options)

Two USB terminals

on front panel

Four-direction

selection button

Jog shuttle for facilitating

moving zoom position

Eight analog input channels

(Yokogawa probe interface compliant)

Logic 16-bit input

(option)

12.1 inch

Approx.

6.6kg

Modest 178 mm depthAbout half of the former model DL7480

Channel 8 is convertible

to 8-bit logic input

(standard feature)

The portable eight-channel DLM4000 is the daily instrument of choice.Maximum easiness of use coupled with minimum depth and weight

12.1-inch large LCD display enables eight waveforms to be easily viewed Portable

178 mm355 mm

Former model

DL7480

Trigger level knob

Soft carrying case

(sold separately)

available

20

Osc

illos

cope

s

Oscilloscopes

Classification Product Model No.

Power supply

DescriptionProbe interface terminal (front panel)(*2)

Probe power (option)/probe power supply (sold separately)

Passive

200 MHz passive probe 701938 DC to 200 MHz, 10:1, 1.5 meters

500 MHz passive probe 701939 DC to 500 MHz, 10:1, 1.3 meters

500 MHz Miniature passive probe

701946 DC to 500 MHz, 10:1, 1.2 meters

200 MHz passive probe(wide temperature range)

702906 DC to 200 MHz, 10:1, 2.5 meters-40°C to 85°C

Passive (High-voltage)

100:1 High voltage probe

701944 DC to 400 MHz, 100:1, 1.2 meters

100:1 High voltage probe

701945 DC to 250 MHz, 100:1, 3.0 meters

Active, FET

1.0 GHz active probe(PBA1000)

701912e

DC to 1.0 GHz, 10:1, 1.2 meters

900 MHz FET Probe 700939e

DC to 900 MHz, 1.5 meters

Differential

1 GHz differential probe(PBDH 1000)

701924e

DC to 1 GHz, 50:1 Max. differential input voltage: ±25 V

150 MHz differential probe(PBDH 0150)

701927e

DC to 150 MHz, 50:1, 500:1Max. differential input voltage: ±140 V (50:1), ±1400 V (500:1)

500 MHz differential probe

701920e

DC to 500 MHz, 10:1, Max. differential input voltage: ±12 V

200 MHz differential probe

701922e

DC to 200 MHz, 10:1, Max. differential input voltage: ±20 V

100 MHz differential probe

701921e (*3)

DC to 100 MHz, 10:1, 100:1, Max. differential input voltage: ±70 V (10:1), ±700 V (100:1)

100 MHz differential probe

700924e (*4)

DC to 100 MHz, 100:1, 1000:1, Max. differential input voltage: ±350 V (100:1), ±1400 V (1000:1)

50 MHz high voltagedifferential probe

701926e (*3)

DC to 50 MHz, 100:1, 1000:1, Max. differezntial input voltage: 700 Vpeak (100:1), 7000 Vpeak (1000:1)

15 MHz differential probe

700925e (*4)

DC to 15 MHz, 10:1, 100:1, Max. differential input voltage: ±50 V (10:1), ±500 V (100:1)

Current

Current probe 701917e

DC to 50 MHz 5 Arms, High-sensitivity

Current probe 701918e

DC to 120 MHz 5 Arms, High-sensitivity

Current probe(PBC100)

701928e

DC to 100 MHz 30 Arms

Current probe(PBC050)

701929e

DC to 50 MHz 30 Arms

Current probe 701932e

DC to 100 MHz, 30 Arms

Current probe 701933e

DC to 50 MHz 30 Arms

Current probe 701931e

DC to 2 MHz, 500 Arms

Current probe 701930e

DC to 10 MHz 150 Arms

Logic

100 MHz Logic probe(PBL100)

701988 Input impedance 1 MΩ Max. toggle frequency: 100 MHz

250 MHz Logic probe(PBL250)

701989 Input impedance: 100 kΩ Max. toggle frequency: 250 MHz

Other

De-skew correction signal source

701936 Voltage/current signal de-skewSupports through-type current transformers and a variety of current probes, including large current probes

Probe power supply 701934 Large current output, external probe power supply (4 outputs)

Probe stand 701919 Diameter of attachable probe ϕ 8 to 13 mm Weight : Approx. 1.5 kg

*1: These specifications are a summary. For details, please refer to the Web site, catalog, and other documentation. *2: Available as standard for the DLM2000, DLM6000, DL6000 and DLM4000 series.*3: Can also be battery operated. *4: A power cable (B9852MJ) sold separately is required. Can also be battery operated. In addition to those listed above, there are other accessories available. For details, please refer to the Web site.When using multiple current probes using the probe power of the main unit, ensure that the total power supply current of the current probes does not exceed the maximum output current of the probe power.

Waveform Measuring Oscilloscopes Accessories

21

Osc

illos

cope

s

Oscilloscopes

Instrument control & data analysis on Your PC

Plug-in for MATLAB software

701992Xviewer

Xviewer is a PC software application designed to work with Yokogawa’s DL/DLM series and the ScopeCorders. Xviewer allows you to display DL-acquired waveform data (using the “Viewer” function), perform file transfers, and control DL/DLM series from a PC.

701991MATLAB tool kit

The MATLAB tool kit for the DL series is a plug-in for MATLAB software. The toolkit can be used to control supported instruments using MATLAB or to acquire data from the instruments to use in MATLAB via a communication interface (GP-IB, USB, Ethernet).

In addition to the above, various kinds of accessory software, free software, LabVIEW drivers, and LabWindows/CVI drivers, can be downloaded from our web site.

XWirepuller/Wirepuller(Free software)

With this software, you can display the front panel of the DLM/DL/SL series on the screen of a PC, and monitor waveform signals. You can perform control from the PC using the mouse and keyboard in the same way as you operate the main unit.

Remote Control Measuring Instrument on Your PC

Oscilloscope Application Software Xviewer/MATLAB tool kit

Free data viewer

XviewerLITE(Free software)

XviewerLITE is a free data viewer software with no restriction for period of service for DLM/DL/SL series. It allows you to display acquired ware form on a PC. Zoom, vertical cursor measuremet and CSV format conversion are possible.

22

Dig

ital P

ower

Ana

lyze

rs

Digital Power Analyzers

Digital Power Analyzers

Yokogawa’s PX8000 and WT Series Power Meters and Power Analyzers:

Advanced Technology and High Reliability for a Wide Range of Power Measurement Solutions

*About CW series Clamp-on Power Meters, please refer to the page 65.

Selection Guide

WT Series

Models

Items

WT310E/WT330E

...P28

WT500

...P23

WT3000E

...P24

WT1800

...P26

PX8000

...P30

Features New Entry Class Digital Power Meters

4 models line up, equipping 5 mA range

(WT310E), 40 A range (WT310EH),

and 2 or 3 CH inputs (WT332E/

WT333E)

Standard Communication I/F and

auto-ranging under integration mode

Low-Middle Class Power Analyzer

Compact half rack size and easy use

Max. 1000 V and 40 A input

Simultaneous measurement U, I, P and

those harmonics components

External USB memory for direct data

saving

Top model of Digital Power Analyzer

With basic power accuracy of

±0.04% of total DC and 0.1 Hz-1 MHz

measurement bandwidth, and up to

four input elements, the model provides

higher-accuracy measurement of

inverter Input/Output efficiency.

Middole Class Digital Power Analyzer

Up to six Input elements in one

instrument (3 phase power input from

two systems in one unit)

8.4-Inch XGA TFT Color LCD

Wide voltage and current input range

A power analyzer with capabilities of

transient power measurement and

waveform parameter measurement

Fast sampling up to 100 MS/s, Broad

bandwidth up to 20 MHz (-3 dB), Trend

measurement of each cycle, Specified

period measurement by cursors

Input elements 1(WT310E,WT310EH), 2 (WT332E),

3(WT333E)1 to 3 1 to 4 1 to 6

Module structure, 1 to 4 power

measurement element

Basic power accuracy

(50/60 Hz)± (0.1% of rdg + 0.05% of rng) ± (0.1% of rdg + 0.1% of rng) ± (0.01% of rdg + 0.03% of rng) ± (0.1% of rdg + 0.05% of rng) ± (0.1% of reading + 0.1% of range)

Power measurement

frequency range

DC, 0.1 Hz to 100 kHz

(WT310EH is up to 20 kHz)DC, 0.5 Hz to 100 kHz DC, 0.1 Hz to 1 MHz DC, 0.1 Hz to 1 MHz DC, 0.1 Hz to 1 MHz

Input voltage range

(for crest factor 3)15/30/60/150/300/600/ V 15/30/60/100/150/300/600/1000 V

15/30/60/100/

150/300/600/1000 V

1.5/3/6/10/15/30/60/

100/150/300/600/1000 V

1.5/3/6/10/15/30/60/100/150/300/600/

1000 V

Input current range

(for crest factor 3)

Direct input: 5 m/10 m/20 m/50 m/100 m/

200 m/500 m/1/2/5/10/20 A (WT310E)

Direct input: 1/2/5/10/20/40 A

(WT310EH)

Direct Input: 500m/1/2/5/10/20 A

(WT332E,WT333E)

External input(option): 2.5/5/10 V, or

50 m/100 m/200 m/500 m/1/2 V

Direct input: 500 m/1/2/5/10/20/40 A

External sensor input (option): 50 m/

100 m/200 m/500 m/1/2/5/10 V

Direct input: 0.5/1/2/5/10/20/30 A or

5 m/10 m/20 m/50 m/100 m/200 m/

500 m/1/2 A

External input:

50 m/100 m/200 m/500 m/1/2/5/10 V

30 A and 2 A can be mixed in one unit

Direct input:

10 m/20 m/50 m/100 m/200 m/

500 m/1/2/5 A or 1/2/5/10/20/50 A

External input (option):

50 m/100 m/250 m/500 m/

1/2/5/10 V

5 A and 50 A can be mixed in one unit

Direct input: 10 m/20 m/50 m/100 m/

200 m/500 m/1/2/5 A

External sensor input: 50 m/100 m/

250 m/500 m/1/2.5/5/10 V

Measurement parameters Voltage, Current, Active power,

Reactive power, Apparent power,

Power factor, Phase angle. Peak

voltage, Peak current, frequency, Crest

factor, Integration (power and current),

Harmonic distortion, Harmonic

components

Voltage, Current, Active power, Reactive

power, Apparent power, Power factor,

Phase angle, Peak voltage, Peak

current, Voltage frequency, Current

frequency Active power integration and

Current integration for both charge/

discharge and sold/bought, crest factor,

Efficiency, harmonic analysis

Voltage, Current, Active power, Reactive

power, Apparent power, Power factor,

Phase angle, Peak voltage, Peak current,

Voltage frequency, Current frequency,

Active power integration, Apparent power

integration, Reative power integration,

Current integration, Corrected power,

Crest factor, Efficiency, Harmonic analysis

Voltage, Current, Active power, Apparent

power, Reactive power, Power factor,

Phase angle, Peak voltage, Peak

current, Voltage frequency, Current

frequency, Active power integration,

Current integration, Crest factor,

Form factor, Impedance, Resistance,

Reactance, Corrected Power, Harmonic

analysis

Voltage, Current, Active power, Reactive

power, Apparent power, Power factor,

Phase angle, Peak voltage, Peak

current, Voltage frequency, Current

frequency

Transient voltage/current/power(Trend of

waveform by cycle), Averaged voltage/

current/power by cursor(waveform

parameters calculation)

Display 7 Segment LED, 4 displays 5.7-inch TFT color LCD 8.4-inch TFT color LCD 8.4-inch XGA TFT color LCD 10.4 inch TFT color LCD (XGA)

External dimensions (mm)

(W × H × D)

213 × 88 × 379 (WT310E and WT310EH)

213 × 132 × 379 (WT332E and WT333E)213 × 177 × 408.5 426 × 177 × 459 426 × 177 × 459 355 × 259 × 180

Weight (kg) 3 (WT310E), 5 (WT330E) 6.5 15 15 6.5 (without any options and paper)

23

Dig

ital P

ower

Ana

lyze

rs

Digital Power Analyzers

• Measurement voltage range: (for crest factor 3)

15/30/60/100/150/300/600/1000 V

• Measurement current range: (for crest factor 3)

Direct input 500 m/1/2/5/10/20/40 A

External sensor input (option)

50 m/100 m/200 m/500 m/1/2/5/10 V

• Frequency range:

DC, 0.5 Hz to 100 kHz

• Measurement Accuracy:

Basic Accuracy (45 Hz ≤ f ≤ 66 Hz and DC)

Voltage/Current/Power

± (0.1% of rdg + 0.1% of rng)

• USB interface to PC is standard feature

• Ethernet communication function is available (optional)

• GP-IB communication function is available (optional)

• Effective of power factor (at cos ϕ =0)

± 0.2% of S (apparent power)

• External dimensions:

Approx. 213(W) × 177(H) × 408.5(D) mm

• Weight: Approx. 6.5 kg (with 3-input element)

Compact and easy to use. The Power Analyzer for the renewable energy generation

The WT500 is a low-middle class power analyzer and

it features a 5.7-inch color TFT and half width racking

compact body that enables single-phase and three-

phase power measurement, achieving ±0.2% of total

basic and DC accuracy, maximum input of 1000 Vrms,

40 Arms and a measurement bandwidth up to 100 kHz.

• Accurate efficiency measurement of DC and AC signals

• RMS, MEAN, DC, AC and RMEAN of voltages and currents

simultaneous measurement.

• Simultaneous measurement of normal U/I/P data and those

harmonic data

• As fast as 100 ms data capturing and store data with all channels

• Separate integration functions for charge/discharge or bought/

sold power

• Integration of power, reactive power, apparent power, and

current enables you to determine a device’s average power

consumption

• Harmonics (DC-50th order) and Total harmonic distortion (THD)

can be measured

• Saving measured data directly to external USB memory

• Measurement values can be saved as images or numerical data,

and can be pasted into reports, analyzed in spreadsheet software,

or used in a variety of other ways

• Easy setup with cursor keys

• GP-IB, USB and Ethernet communication are available

WT500 1 input element model

WT500 2 input elements model

WT500 3 input elements model

UL/CSA standard

VDE standard

SAA standard

BS standard

GB standard

GP-IB interface

Ethernet interface

External sensor input for 760201

External sensor input for 760202

External sensor input for 760203

Harmonic Measurement

Delta computation (760202/03 only)

Add-on Frequency Measurement (760202/03 only)

VGA Output

Note: Adding input modules after initial product delivery will require rework at the factory. Please choose your

models and configurations carefully, and inquire with your sales representative if you have any questions.

Model

760201

760202

760203

Power cord

Options

-D

-F

-R

-Q

-H

/C1

/C7

/EX1

/EX2

/EX3

/G5

/DT

/FQ

/V1

Suffix Codes Description

Overview of a Photovoltaic Power Conditioner

Solar cell

module

WT500 Power Analyzer

Booster

converter Load

Power Grid

DC/AC

converter

Power Analyzer WT500

WT500

Bulletin 7602-00E

Basic Specifications

Overview

Features

Model Number and Suffix Codes

24

Dig

ital P

ower

Ana

lyze

rs

Digital Power Analyzers

The World Highest Class*1 Precision and Stability with Basic Power Accuracy: ±0.04% of total(*1: As of May 2016, for power accuracy in a three-phase power meter as investigated by Yokogawa)

Precision Power Analyzer WT3000E

Bulletin WT3000E-01EN

Features

WT3000E

Inverter Motor Load

Input waveform Output waveform

Analog or pulse input(Revolution speed and torque)

The WT3000E has the highest precision of all the Yokogawa power analyzers in the WT series. The WT3000E can be used as a reference instrument for calibration and to measure the power and efficiency of converters such as an inverter. It helps increase efficiency in evaluation and testing.

Basic power accuracy ±0.04% of total, the highest precision of all power analyzers in the WT series, 2 A and 30 A Input Element can be installed together

Up to four input elements to achieve accurate measurement of input and output conversion efficiency

Motor efficiency and total efficiency measurement of the motor option (/MTR)

Simultaneous harmonic measurement without changing measuring modes (option)

Wide bandwidth harmonic measurement between 0.1 Hz and 2.6 kHz of the fundamental waveform (option)

Harmonic measurement compliant with IEC61000-3-2/12 (option)

Voltage fluctuation/flicker measurement compliant with IEC61000-3-3/11 (option)

High-precision measurement of motor/inverter efficiency

Growing interest in energy conservation of late increases the need to evaluate motor/inverter efficiency with high precision. The WT3000E offers up to four voltage and four current inputs and is capable of high-precision measurement of single-phase input and three-phase output to evaluate the inverter efficiency.A motor evaluation function (/MTR option) allows you to observe changes in voltage, current, and power while at the same time observing changes in revolution speed and torque, and calculate and display mechanical power and total efficiency.Also, you can synchronize two units and take measurements, and WTViewerE free software for data acquisition allows you to compare the power of the two units and calculate the efficiency.

Measuring instantaneous peak power in photovoltaic power generation

In photovoltaic power generation, MPPT control varies the voltage to maximize energy harvested from the solar panel. The WT3000E allows you to measure voltage, current, and power, as well as peak voltage and peak current (on the plus and minus sides, respectively). Also, the user-defined MATH allows you to measure the instantaneous peak power (on the plus and minus sides).

Cycle-by-cycle function allows measuring voltage, current, and power

for each cycle

To observe the rising characteristic of a starting motor or the like, you may want to acquire data for each cycle instead of at specified time intervals. The cycle-by-cycle measurement function of the WT3000E allows you to measure the following parameters: voltage, current, active power, apparent power, reactive power, power factor, speed, torque, and mechanical power. Up to 3,000 periods of measurements can be taken.

Example of cycle-by-cycle measurement of three-phase voltage, current, active power, and apparent power

Cycle-by-cycle data computation

MPPT: Maximum Power Point TrackerExample of measurement results of voltage, current, and power under control

Example of power (P1) and instantaneous peakpower on the plus (F1) and minus (F2) sides

Cu

rren

t

Po

we

r

Voltage

Peak power

* This is just an illustration. The actual measurement may be affected by noise.

Example of measurement data display on the primary and secondary sides

Primary side Secondary side

Inverter efficiency

Applications to Utilize WT3000E Precision Power Analyzer’s Capabilities

25

Dig

ital P

ower

Ana

lyze

rs

Digital Power Analyzers

Portable devices, hybrid electric and electric vehicles, etc.

Battery

Example of display of total watt hours (on the plus and minus sides)

Charge

Discharge

LED

Switching

regulatorAC power supply

Model Number and Suffix Code

Specifications

Voltage direct input range : 15/30/60/100/150/300/600/1000 V

Current direct input range : 0.5/1/2/5/10/20/30 A or 5 m/10 m/20 m/

50 m/100 m/200 m/500 m/1/2 A

Current sensor input range : 50 m/100 m/200 m/500 m/1/2/5/10 V

Frequency bandwidth : DC, 0.1 Hz to 1 MHz

Basic accuracy (45 Hz to 66 Hz) (30 A input element)

Voltage/current ±(0.01% of rdg*1 + 0.03% of rng*2)

Power ±(0.01% of rdg*1 + 0.03% of rng*2)

Data update period : Select from 50 ms, 100 ms, 250 ms,

500 ms, 1 s, 2 s, 10 s, and 20 s

Power factor influence: ±0.03% of S (apparent power)

when cos ϕ =0

A/D converter Simultaneous voltage and current

conversion, 16-bit resolution

Conversion speed approx. 5 μs

Display 8.4-inch color TFT LCD monitor

Built-in printer (option) Thermal line-dot, paper width 112 mm

PC card port, USB port (option)

External dimensions : Approx. 426 (W) × 177 (H) × 459 (D)

mm (excluding protrusions)

Weight : Approx. 15 kg (main unit, four input

elements, options)

*1: 1 rdg: reading *2: 1 rng: range

Model Suffix code Description

WT3001E Precision Power Analyzer One Input Element Model

-2A0 -30A1 None 2 A Input Element 30 A ×1 Input Element

-2A1 -30A0 2 A ×1 Input Element None 30 A Input Element

WT3002E Precision Power Analyzer Two Input Elements Model

-2A0 -30A2 None 2 A Input Element 30 A ×2 Input Elements

-2A1 -30A1 2 A ×1 Input Element 30 A ×1 Input Element

-2A2 -30A0 2 A ×2 Input Elements None 30 A Input Element

WT3003E Precision Power Analyzer Three Input Elements Model

-2A0 -30A3 None 2 A Input Element 30 A ×3 Input Elements

-2A1 -30A2 2 A ×1 Input Element 30 A ×2 Input Elements

-2A2 -30A1 2 A ×2 Input Elements 30 A ×1 Input Element

-2A3 -30A0 2 A ×3 Input Elements None 30 A Input Element

WT3004E Precision Power Analyzer Four Input Elements Model

-2A0 -30A4 None 2 A Input Element 30 A ×4 Input Elements

-2A1 -30A3 2 A ×1 Input Element 30 A ×3 Input Elements

-2A2 -30A2 2 A ×2 Input Elements 30 A ×2 Input Elements

-2A3 -30A1 2 A ×3 Input Elements 30 A ×1 Input Element

-2A4 -30A0 2 A ×4 Input Elements None 30 A Input Element

Power Cord -D UL/CSA standard, PSE compliant

-F VDE standard

-H GB standard

-N NBR standard

-Q BS standard

-R AS standard

Options /G6 Advanced Calculation

/B5 Built-in Printer

/FQ Add-On Frequency Measurement

/DA 20 ch DA Output

/V1 VGA Output

/C12* USB Port (PC)

/C2* Serial (RS-232) Interface

/C7 Ethernet Interface

/C5 USB Port (Peripheral)

/FL Voltage Fluctuation/Flicker

/MTR Motor Evaluation Function

* Only one can be selected.

* For common optional accessories, please see page 35

Example of LED driving circuit and measurement

Lighting equipment is shifting from incandescent to fluorescent lamps. Furthermore, in recent years, long-life, low power consumption LEDs are attracting attention. To increase the power conversion efficiency of an LED driving circuit (drive module), it is necessary to measure the voltage, current, and power of input and output with high precision. The WT3000E provides the best-in class accuracy to measure the power conversion efficiency of input and output.

Measuring battery charge and discharge (Ah/Wh)

For battery-powered equipment such as portable devices and electric-powered bicycles, engineers must often perform short-duration charge/discharge tests under actual operating conditions. Since the WT3000E employs a digital sampling system, each rapidly changing charge/discharge current and power can be integrated without gaps. This is effective in the evaluation of ampere-hours and watt-hours for calculating battery life.

Rear panel (4 input elements and options)

2 A and 30 A input Element can be installed together in one unit.

Example of DC voltage, current, and power at three points and conversion efficiency measurement.

26

Dig

ital P

ower

Ana

lyze

rs

Digital Power Analyzers

As three phase mean

One phase current waveform

Broad Ranges Power Measurement with One Unit

The WT1800 High performance power analyzer can

measure both the small currents of products called

energy saving designed as well as the large currents

involved in large-sized loads. As it handles voltages

ranging from 1.5 V to 1000 V, it has a wide variety of

uses. Since 3 phase power can be input from two

separate systems (6 inputs), you only need one WT1800

to simultaneously measure Input/Output signals from

inverters with normal/harmonics data as fast as 50 ms.

• Basic Power Accuracy ±0.15% of total

• DC Power Accuracy ±0.15% of total

• Voltage/Current Bandwidth 5 MHz (-3 dB, typical)

Voltage, 5 A direct input, external sensor input

• Sampling Rate 2 MS/s (16-bit resolution)

• Input Element number Max. 6

• Current Measurement 100 μA to 55 Arms direct

High Performance Power Analyzer WT1800

WT1800

Bulletin WT1800-00EN

Inverter

Input

Convert AC to DC signals

Inverter section

Modulate DC signal and convert to any AC signals indicates measurement points and input to the

power analyzer.

M indicates connecting the motor output to the

motor signal input (/MTR) of the power analyzer

Drive circuitConverter section

Motor Torque/rotation speed sensor

Load

Advantages of WT1800

• 5 MHz range and 2 MS/s high-speed samplingThe vertical resolution in power measurements is one of the important

elements for high-precision measurements.

The WT1800 is capable

of 16-bit high resolution

and approximately 2 MHz

sampling to make it possible

to measure faster signals with

higher precision.

• ms response capability (/HS Option)The High Speed data capturing /HS option can measure

∑Urms, ∑Irms and ∑P from single phase (DC signal)

and three phase devices every 5 ms (When External

Synchronization is OFF) or, 1 ms to 100 ms when External

Synchronization is ON (depending on the frequency of the

clock signal). It outputs data in 1 s blocks to internal/external memory or to

a PC through a communications interface.

The average characteristic is set using the cutoff frequency of the HS

filter for measured data during 5 ms or 1 ms to 100 ms period. The cutoff

frequency can be varied from 1 Hz to 1,000 Hz in 1 Hz steps.

The following measurements can be performed for up to the 500th orderSingle harmonic measurement (/G5 option)Dual harmonic measurement (/G6 option)

• Dual harmonic measurement (/G6 option)The WT1800 is capable of performing two-line simultaneous harmonic

measurements with one unit for the first time in the industry.

The ability to simultaneously measure harmonics for the input and output

signals not only reduces the switching time but also makes it possible to

perform simultaneous data analysis for the input and output, which has not

been possible with the previous models.

Dual harmonicmeasurementDual harmonicmeasurement

Up to the500th orderUp to the

500th order

Simultaneousinput/outputmeasurement

Simultaneousinput/outputmeasurement

Approx.2 MS/s 16-bit

Approx.2 MS/s 16-bit

Voltage/current range

5 MHz

Voltage/current range

5 MHz

Data analysis and graph drawing by data calculation software

Comparison between a phase current waveform and three phase current values of every 5 ms

OverviewThe WT1800 is capable of performing up to 6 power input measurements to make it possible to perform an inverter efficiency test between the input and output in inverter evaluation.

In addition, a motor evaluation function (option) makes it possible to simultaneously monitor voltage, current, and power changes, as well as rotation speed and torque changes.

Overview

Input/Output Efficiency Measurements of Inverters, Matrix converters, Motors, Fans, and Pumps

27

Dig

ital P

ower

Ana

lyze

rs

Digital Power Analyzers

• Measurement Voltage range: (for Crest factor 3) 1.5/3/6/10/15/30/60/100/150/300/600/1000 V• Measurement Direct Current range: (for Crest factor 3) 5 A input element 10 m/20 m/50 m/100 m/200 m/500 m/1/2/5 A 50 A input element 1/2/5/10/20/50 A• Measurement External Current Sensor range: (for Crest Factor 3) 50 m/100 m/200 m/500 m/1/2/5/10 V• Band width: DC, 0.1 Hz to 1 MHz (5 A direct Current input, External Current Sensor input) DC, 0.1 Hz to 200 kHz (50 A direct Current input)• Basic Accuracy: (45 Hz ≤ f ≤ 66 Hz) ±(0.1% of reading + 0.05% of range)• DC Accuracy: ±(0.05% of reading + 0.1% of range)• A/D converter: Sampling frequency 2 MS/s Resolution 16 bit• External dimensions: Approx. 426 (W) × 177 (H) × 459 (D) mm• Weight: Approx. 15 kg (with 6-input element)

*5 A and 50 A Input Element can be installed in one unit

Solar cell module (outdoors)Mega solar system (outdoors)

Pyranometer (photovoltaic power generation)

Vane anemometer (wind power generation)

Power conditioner

Boost converter

AC/DC converter

Current charge control

Power storage system

Charge/discharge

Power sold/bought

Power Flow of Photovoltaic Power Generation

Reverse power flow

Load

Grid interconnection or smart grid

(next-generation power network)Storage batteryPlug-in HV, etc.

indicates measurement points and input

to the power analyzer. (A) indicates

connecting the sensor signals to the

auxiliary input (/AUX) of the power analyzer.

Advantages of WT1800

• Max. 1000 V/50 A x 6-line direct measurement

Direct input terminals in a voltage range from 1.5 V to 1000 V and current range from 10 mA to 5 A or 1 A to 50 A make it possible to perform high-precision measurements without using a current sensor.Furthermore, power conditioner evaluation requires multiple-channel power measurements, such as inputs/outputs from a boost converter, inverter, and storage battery. The WT1800 is capable of providing up to 6 channels of power inputs to make it possible to simultaneously perform power measurements at multiple points with one unit. In addition, two units can be operated in synchronization for multi-channel power evaluation.

Wide voltage/current rangeWide voltage/current range

Synchronizedoperation

Synchronizedoperation

• Maximum Power Peak Tracking (MPPT) measurement

In photovoltaic power generation, an MPPT control is performed to effectively utilize voltage generated by photovoltaic cells in an attempt to maximize the harvested power.The WT1800 is capable of measuring not only the voltage, current, and power but also the voltage, current, and power peak values (plus (+) and minus (-) sides, respectively). Also, the maximum power peak value (plus (+) and minus (-) sides) can be measured.

MPPTMPPT

Maximum powerpeak value

Maximum powerpeak value

Typical voltage, current, and power measurements in MPPT control

* This is just an illustration.Actual measurements are

affected by noise.

Voltage value

Max. power value

Currentvalue

powervalue

* The numbers in the "Description" column have the following meanings.50 A: 50 A input element, 5 A: 5 A input element

Elements are inserted in the order shown starting on the left side on the back.* GPIB, Ethernet and USB communication come standard.

Model Suffix codes Description

WT1801 -01 50 A -10 5 A

-02 50 A 50 AWT1802 -11 5 A 50 A -20 5 A 5 A

-03 50 A 50 A 50 A

WT1803 -12 5 A 50 A 50 A -21 5 A 5 A 50 A -30 5 A 5 A 5 A

-04 50 A 50 A 50 A 50 A -13 5 A 50 A 50 A 50 AWT1804 -22 5 A 5 A 50 A 50 A -31 5 A 5 A 5 A 50 A -40 5 A 5 A 5 A 5 A

-05 50 A 50 A 50 A 50 A 50 A -14 5 A 50 A 50 A 50 A 50 A

WT1805 -23 5 A 5 A 50 A 50 A 50 A -32 5 A 5 A 5 A 50 A 50 A -41 5 A 5 A 5 A 5 A 50 A -50 5 A 5 A 5 A 5 A 5 A

-06 50 A 50 A 50 A 50 A 50 A 50 A -15 5 A 50 A 50 A 50 A 50 A 50 A -24 5 A 5 A 50 A 50 A 50 A 50 AWT1806 -33 5 A 5 A 5 A 50 A 50 A 50 A -42 5 A 5 A 5 A 5 A 50 A 50 A -51 5 A 5 A 5 A 5 A 5 A 50 A -60 5 A 5 A 5 A 5 A 5 A 5 A

-D UL/CSA standard -F VDE standard

Power cord -R AS standard -Q BS standard

-H GB standard-N NBR standard

Languages

-HE Default setting English menu-HG Default setting German menu-HC Default setting Chinese menu-HR Default setting Russian menu

/EX1 External current sensor input for WT1801 /EX2 External current sensor input for WT1802 /EX3 External current sensor input for WT1803 /EX4 External current sensor input for WT1804 /EX5 External current sensor input for WT1805 /EX6 External current sensor input for WT1806 /B5 Built-in printerOptions /G5 Harmonic Measurement /G6 Simltaneous Dual Harmonic Measurement /DT Delta Computation /FQ Add-on Frequency Measurement /V1 RGB output /DA 20-channel DA Outputs /MTR Motor Evaluation Function /AUX

/HS Auxilia

High Speed Data Capturingry Sensor Inputs

WT1800 Single input element

WT1800 2 input elements

WT1800 3 input elements

WT1800 4 input elements

WT1800 5 input elements

WT1800 6 input elements

Standard option

Additional option

Only one can be selected

Only one can be selected

Note: Adding input elements after initial product delivery will require rework at the factory. Please choose your models and configurations carefully, and inquire with your sales representative if you have any questions

Overview

Energy generated by photovoltaic cell modules and wind turbines is converted from DC to AC by a power conditioner. Furthermore, the voltage is converted by a charge control unit for

the storage battery. Minimizing losses in these conversions improves efficiency in the overall energy system. The WT1800 is capable of providing up to 6 channels of power inputs per

unit to make it possible to measure the voltage, current, power, and frequency (for AC) before and after each converter, as well as converter efficiency and charging efficiency.

Power Generation and Conversion Efficiency Measurements in New Energy Markets, including Photovoltaic and Wind Power Generation

Model Number and Suffix Code

Basic Specifications

28

Dig

ital P

ower

Ana

lyze

rs

Digital Power Analyzers

• Basic power accuracy: ±0.15% of total

• Measurement frequency range: DC, 0.1 Hz to 100 kHz (to

20 kHz for WT310EH)

• Fast data update rate: 100 ms

• Auto data update rate function for fluctuating input

• Small current measurement: 5 mA range available (WT310E)

• 40 A large current available (WT310EH)

• Multiple communication interfaces: USB, GP-IB or RS-232

and Ethernet (option and supports the Modbus/TCP

Protocol)• Integration power measurement auto ranging function• Simultaneous measurement of harmonics with voltage, current,

and power (mode switching is not required, but the included a PC software is required )

• Compact half-rack mount size • The included standard PC software allows you to display values,

harmonic bar graph, and waveforms

The WT300E series is the enhanced 5th generation of

Yokogawa’s compact power meter portfolio.

New compact WT300E series for reliable power measurement

Useful in the development of home appliances and office equipment as well as

in the measurement of power consumption and standby power on production line

Digital Power Meters WT300E

WT310E (1 ch) WT310EH

(1 ch, MAX40A)

WT332E (2 ch)/

WT333E (3 ch)

New Functions to Improve Measurement Efficiency

Standard accessories Power cord(1 set), Rubber foot(1 set), Current input protective cover(each 1 set), Start up guide(1 set), Connector (provided

only with /DA4 or /DA12, each 1 set), Safety terminal adapter 758931(provided two adapters in a set times input element number), CD(1 piece,included the startup guide, user guide, instruction manual and the communication manual by PDF data, and Viewer Software)

Model Suffix Code Description

WT310E 1 Input element model

Communication Interface -C1 select one

GP- IB

*USB is standard -C2 RS- 232

Power Cord -D UL, CSA standard, PSE

-F VDE standard

-R AS standard

-Q BS standard

-H GB standard

-N NBR standard

Optional function /C7 Ethernet interface

/EX1 External sensor input 2.5 V/5 V/10 V

/EX2 External sensor input 50 mV/100 mV/200 mV/500 mV/1 V/2 V

/G5 Harmonics Measurement

/DA4 D/A- output (4 CH)

Model Suffix Code Describe

WT310EH 1 Input element /High current model

Communication Interface -C1 select one

GP- IB

*USB is standard -C2 RS- 232

Power Cord -D UL, CSA standard, PSE

-F VDE standard

-R AS standard

-Q BS standard

-H GB standard

-N NBR standard

Optional function /C7 Ethernet interface

/EX1 External sensor input 2.5 V/5 V/10 V

/EX2 External sensor input 50 mV/100 mV/200 mV/500 mV/1 V/2 V

/G5 Harmonics Measurement

/DA4 D/A- output (4 CH)

Model Suffix Code Describe

WT332E 2 Input elements model

WT333E 3 Input elements model

Communication Interface -C1 select one

GP- IB

*USB is standard -C2 RS- 232

Power Cord -D UL, CSA standard, PSE

-F VDE standard

-R AS standard

-Q BS standard

-H GB standard

-N NBR standard

Optional function /C7 Ethernet interface

/EX1 External sensor input 2.5 V/5 V/10 V

/EX2 External sensor input 50 mV/100 mV/200 mV/500 mV/1 V/2 V

/G5 Harmonics Measurement

/DA12 D/A- output (12 CH)

Only one can be selected

Only one can be selected

Only one can be selected

Bulletin WT310-01EN

• Direct voltage input range 15/30/60/150/300/600 V• Direct current input range 5/10/20/50/100/200 mA (WT310E only) 0.5/1/2/5/10/20 A (Common for WT300E series) 1/2/5/10/20/40 A (WT310EH only)• External current input range (optional) 2.5/5/10 V or 50 m/100 m/200 m/500 m/1/2V• Frequency range: DC, 0.1 Hz to 100 kHz (up to 20 kHz for WT310EH)• Basic accuracy (45 Hz to 66 Hz) Voltage/current ±(0.1% of rdg*1 + 0.05% of rng*2) Power ±(0.1% of rdg*1 + 0.05% of rng*2)• Influence of power factor (when cos ϕ =0) Add ±0.1% of S• Data update rate: 100 m/250 m/500 m/1/2/5/10/20s, Auto• External dimensions · WT310E/WT310EH: Approx. 213(W) × 88(H) × 379(D) mm

(excluding protrusions) · WT332E/WT333E: Approx. 213(W) × 132(H) × 379(D) mm

(excluding protrusions)• Weight: Approx. 3.0 kg (WT310E/WT310EH), approx. 5.0 kg (WT332E/

WT333E)

*1 rdg: reading, *2 rng: range

Range skip (range configuration) functionThe WT300E series is equipped with the range skip (range configuration) function of the high-end models, which reduces the range-change time in auto-ranging mode that is long due to the wide voltage and current ranges. This function skips the ranges other than the pre-selected range to speed up the change to the selected range in auto-ranging mode. (The included WTViewerFreePlus software is required for the setting)

Action of Yokogawa’s previous modelInput signal changes

Range change ends

Change available ranges stepwise

Action of WT310E/WT330E series

Range change ends Change to selected next range

Integration measurement auto-ranging functionThis is the industry’s first function to automatically change the range in response to changes of the consumption power and current values in integration mode. This function continues integration even if the level of the input exceeds the maximum of the selected range and the range is changed to a higher level as a result of a rapid change in the conditions. This function eliminates the need for repeating the test even if a range is exceeded, thus reducing the evaluation time. Furthermore, separate power integration for each polarity (±Wh), current integration (Ah), and DC integration (charge/discharge) are also available. (The measurement accuracy depends on the input level and variation. It is recommended to set a fast data update rate.)

Specifications

Features

Models and Suffix Codes

29

Dig

ital P

ower

Ana

lyze

rs

Digital Power Analyzers

WTViewerFreePlus For WT300E Series (included)

WT300E Series can be used for a Variety of Applications

Comparison between WT210/230 series, WT300 series and WT300E series

The WTViewerFreePlus software installed on a PC uses a USB, GP-IB/RS-232, or Ethernet (optional) interface to capture, transfer, and display* five or more numeric values, bar graph of harmonic order components, trend graph of measurement data, or voltage/current waveforms that cannot be displayed on the LED display of the WT300E series. The use of this software extends the application range of the WT300E series. With the aim of simplifying the connection and setup, the details were redesigned so that the communication function is recognized automatically, a dedicated setting window was added, and all measurement data can be displayed simultaneously. * Waveform display requires the /G5 harmonic measurement option.

Setting Window Measurement Window

- Compact half rack mount size helps customers build smaller test systems

with a better Return on Investment (ROI).

- D/A output function and Modbus/TCP Protocol (/C7 option) for data

recording

- Multiple communication interfaces. USB, RS-232 or GP-IB and Ethernet

capability.

The simultaneous measurement of power consumption parameters such as U, I, P, frequency,

Power Factor and Harmonics for production line or QA testing results in reduced tact times.

Thus testing is faster and cheaper. The DA output and communication interfaces enable data to

be remotely and flexibly captured.

Production line or QA testing of electric Devices

PC

- Integration measurement for long period

- D/A output function and Modbus/TCP Protocol (/C7 option) for data

recording

- DC, 0.1 Hz to 100 kHz broad bandwidth capabilityThe WT300E series provides reliable current integration (Ah) and Energy (Wh) measurement for

up to 10,000 hours (approx. 1 year). The D/A option is used to save and monitor the

measurement results (WT310E/WT310EH: 4 ch, WT332E/WT333E: 12 ch). An external recorder

or data logger like, a ScopeCorder, can be used to save this D/A function data along with other

parameters such as temperatures, torque and rotation speed.

Duration testing and efficiency measurement for industrial motors and rotating machinery

Pump

Recorder

D/A outputor Modbus/TCP(/C7 option)

Voltage

Current Probe

Three phase system

Enhancement points from the WT310/WT330 Changed points from the WT210/WT230

WT300E series WT300 series WT210/WT230Basic power measurement accuracy (50/60 Hz)

0.1% of reading + 0.05% of range 0.1% of reading + 0.1% of range 0.1% of reading + 0.1% of range

Influence of power factor When power factor ( ) = 0 (S: apparent power) ±0.1% of S for 45 Hz ≤ f ≤ 66 Hz

When power factor ( ) = 0 (S: apparent power) ±0.2% of S for 45 Hz ≤ f ≤ 66 Hz

When power factor ( ) = 0 (S: apparent power) ±0.2% of S for 45 Hz ≤ f ≤ 66 Hz

Frequency bandwidthDC, 0.1 Hz to 100 kHz

(WT310EH DC, 0.1 Hz to 20 kHz)DC, 0.5 Hz to 100 kHz

(WT310EH DC, 0.5 Hz to 20 kHz)DC, 0.5 Hz to 100 kHz

Direct input Current rangeWT310E: 12 ranges/5 mA to 20 A,

WT310EH: 6 ranges/1 to 40 A WT332E/WT333E: 6 ranges/0.5 to 20 A

WT310: 12 ranges/5 mA to 20 A, WT310HC: 6 ranges/1 to 40 A

WT332/WT333: 6 ranges/0.5 to 20 A

WT210: 12 ranges/5 mA to 20 A, WT230-2ch/WT230-3ch:

6 ranges/0.5 to 20 A

External current inputEX1: 2.5/5/10 [V]

EX2: 50 m/100 m/200 m/500 m/1/2 [V] (OP.)EX1: 2.5/5/10 [V]

EX2: 50 m/100 m/200 m/500 m/1/2 [V] (OP.)EX1: 2.5/5/10 [V]

EX2: 50 m/100 m/200 m [V] (OP.)Expansion of effective input range for voltage & current (CF = 6A)

2% to 260%*1 No No

Expansion of maximum displaying value for voltage & current (CF = 6A)

2% to 280%*2 No No

Simultaneous measurement of RMS, Voltage MEAN & DC

Yes*3 Yes*3 No

Frequency measurement 2 channels (voltage and current) 2 channels (voltage and current) selected voltage or current (one)Number of display item 4 items 4 items 3 itemsSampling rate Approximately 100 kS/s Approximately 100 kS/s Approximately 50 kS/sData Update rate 100 m/250 m/500 m/1/2/5/10/20 sec, Auto 100 m/250 m/500 m/1/2/5 sec 100 m/250 m/500 m/1/2/5 secHarmonic measurement Yes (OP, /G5) Yes (OP, /G5) Yes (OP, /HRM)THD calculation maximum order setting Yes (OP, 1 to 50th) Yes (OP, 1 to 50th) NoAuto ranging of integration Yes Yes No

Communication interface

USB Yes Yes No

GP-IB Yes GP-IB or RS-232 Yes GP-IB or RS-232 Yes (OP) GP-IB or RS-232C

RS-232 Yes GP-IB or RS-232 Yes GP-IB or RS-232 Yes (OP) GP-IB or RS-232CEthernet Yes (OP) Yes (OP) NoModbus/TCP (Ethernet) Yes (OP, /C7) No No

IEEE standard for GP-IB IEEE488.2 IEEE488.2 IEEE488.1 and IEEE488.2Comparator function Yes Yes Yes

Viewer software (setting & data capturing) Free (included) Free (included) Free (download)

*1: WT310EH input range is 2% to 260% (20 A range only up to 200%)

*2: WT310EH input range is 2% to 280% (20 A range only up to 220%)

*3: Simultaneous, mode independent measurement using the WTViewerFreePlus PC software.

* A command compatible mode for the previous WT200 series is prepared. (IEEE488.2 only)

In that mode, the WT300E series and WT300 series works identically to a WT200 series except for the Store (and

recall operation) and the Compare functions.

* Modbus/TCP communication requieres /C7 Ethernet option.

30

Dig

ital P

ower

Ana

lyze

rs

Digital Power Analyzers

Power Analyzer Capable of Measuring Waveform Parameters and Transient Power

• High-speed sampling and wide range measurement

The power of devices driven at a high frequency can be measured at a 100

MS/s sampling rate, at a 12-bit resolution, and in the 20 MHz range*1.

• Waveform measurement function

Instantaneous power waveforms can be displayed as standard in addition to

voltage and current waveforms, and power changes can be observed directly.

Voltage, current, and power waveforms for each cycle can be calculated

and numerical values can be displayed by cursor.

The average voltage, current, and power values in a specified period by

the cursor can be calculated.

Acquisition memory is up to 100 M points per channel (when equipping

the /M2 option), allowing for capturing and displaying detailed waveforms.

• Waveform analysis function

Up to the 500th order harmonic components can be measured

simultaneously (when installing the /G5 option).

2-channel FFT function is available as standard.

• De-skew (phase compensation) function when using an external power

sensor, etc. is available.

• Motor characteristics can be evaluated (mechanical output calculation

with torque and rotation speed input, as well as analog and pulse input).*1: Direct current input at 10 MHz (-3 dB typical)

The PX8000 is a compact sophisticated power analyzer that

can incorporate up to four measurement power elements.

It can calculate the transient voltage, current, and power

for each cycle, the average voltage, current, and power

between cursors, and measure waveform parameters.

Precision Power Scope PX8000

Various functions to measure transient power*2

Trend power calculation for each cyclePower trend waveform for each cycle can be calculated using the User Defined Computation (waveform calculation, MATH) at up to 4 M points. The captured waveforms can be used to obtain the value for a particular cycle and calculate the difference between cycles using the cursor function.

Viewer software PowerViewerPlus

Waveform data in the

displayed entire range

can be displayed on the

numerical display screen.

Waveform parameters to be

calculated can be set in detail.

Start screen

Measurement results display screen

Measured values of waveforms

displayed between cursors

indicating the start and stop

positions can be displayed on

the numerical display screen.

The instantaneous power

waveform indicates the trend

of power change. The value

at any point in time can be

displayed using the cursor.

Settings of the trend

calculation using the User

Defined Computation

(MATH) function.

The cursor (horizontal, vertical, and marker) allows you to display the numerical

data of trend waveform for each cycle calculated using the User Defined Calculation

(MATH).

A PC application software for the PX8000, 760881 PowerViewerPlus allows you to transfer measurement data of the PX8000 to a PC to display and analyze a large amount of waveform data on the PC.

PX8000

Simultaneous calculation and display of instantaneous power waveformsThe PX8000 calculates the instantaneous power waveform simultaneously with the voltage and current waveforms. The instantaneous waveform can be obtained as the product of the voltage and current waveforms that are sampled at the same time. This function is a standard function so no special setting is required. This instantaneous power value can be displayed using the cursor.

Power calculation in a range specified by the cursorThe average numerical values in a range specified by the cursor can be calculated. Values between cursors of waveforms displayed on the screen can be displayed on the upper numerical display screen. The MEASURE function cursor can be used for the measurement in the specified range.

*2: Accuracy is not specified for the numerical data of the measured transient power.

Bulletin PX8000-01EN

Features

31

Dig

ital P

ower

Ana

lyze

rs

Digital Power Analyzers

• Voltage direct input range: 1.5/3/6/10/15/30/60/100/150/300/600/1000 Vrms• Current direct input range: 10 m/20 m/50 m/100 m/200 m/500 m/1/2/5 Arms• Current sensor input range: 50 m/100 m/200 m/500 m/1/2/5/10 Vrms• Frequency range: DC to 20 MHz (-3 dB, voltage and current

sensor input) DC to 10 MHz (-3 dB, current direct input)• Power basic accuracy (45 Hz to 66 Hz) ±(0.1% of reading + 0.1% of range)• Influence of power factor error (cos ϕ = 0): ±0.15% of S (apparent power)• A/D converter: Maximum sampling rate 100 MS/s Resolution 12-bit• Acquisition memory: Standard: 10 M points per channel Max: 100 M points per channel (/M2 option)• Maximum waveform viewing time: 20 minutes (not dependent on the memory size)• History memory: This function can save up 1,000 records of waveform

data and display and calculate them as needed(when the /M2 option installed)

• Waveform display: Up to 16 waveforms can be displayed. Voltage and current waveforms and simultaneous

power waveform can be displayed.• Snapshot: Waveform at an arbitrary moment on the screen can

be saved. • De-skew (phase compensation) function: Phase difference between the voltage and current

modules is compensated.• Trend measurement (waveform measurement, MATH): Voltage, current, and power waveform calculation for

each cycle• Calculation in the specified period (waveform parameter calculation, MEASURE):

Average value between cursors can be measured.• Simultaneous harmonic measurement: Up to the 500th order harmonic measurement (/G5 option)• 2-channel FFT function available as standard• Printer: Screens can be copied (/B5 option)• External storage: USB port (×2), SD card• Video output: RGB analog, video output• Display unit: 10.4-inch color TFT XGA display• GP-IB, Ethernet, and USB communication available as standard• IRIG function: Data measured with multiple PX8000 units can be

synchronized (/C20 option)• Sensor power supply 4CH DC power supply ±15Vdc Max. of 1A/CH• External dimensions: 355 (W) × 259 (H) × 180 (D) mm (excluding protrusions)• Weight: Approximately 6.5 kg (main unit only, excluding paper and options)* For common options and accessories, see Page 35.

Power measurement elements (voltage and current modules) and Auxiliary (AUX) module

Application example: Inverter evaluation using the PX8000 and DL850EV

Overview of the evaluation with the PX8000 and DL850EVElectric vehicles (EVs) and hybrid electric vehicles (HEV) are made of a large number of electrical and mechanical parts. To evaluate their efficiency, electrical parts and mechanical parts must be measurement simultaneously. The DL850EV is a data acquisition instrument that can measure many types of physical quantities at multiple points simultaneously. On the other hand, the PX8000 measures the efficiency of the inverter and the motor, as well as transient changes at every moment based on the electrical signals of voltage and current and the mechanical output calculated from the torque and rotation speed.

Functions to prevent mismatch between the voltage and current modules

Safety design

Power measurement elements comprising a pair of the voltage module (760811) and current module (760812/760813) are required to measure power. You need to connect at least one set of power measurement element, the voltage module to slot 1 and the current module to slot 2.Note: Up to 3 AUX modules can be connected to odd number slots 3, 5, and 7 except for slot 1.

Current module

760813 760812

Voltage module

760811

AUX module

DL850EV

PX8000

CAN

Power measurement elements

- Warning message- Check on the overview screen ‘(you can

check paired modules)

Different types of voltage input terminal and current input terminal are used to keep the user from confusing one from the other.

Voltage input

terminal type

(female-type

safety terminal)

Current input

terminal type

(male-type

safety terminal)

Inverter

Input (2)(1) (3)

(4)

Drive circuitBoost

converter

Drive motor

Torque/rotation speed sensor

Load

Battery

Modulate the DC signal to convertit to an arbitrary AC signal

(1) Measuring battery output (DC)

(2),(3) Inverter output measurement and transient

power measurement

(4) Mechanical output measurement of motor

(torque and rotation speed measurements)

Product name Model Suffix code Description

Precision Power Scope

PX8000 Precision Power Scope main unit

-DUL and CSA standards(PSE compliant, 3-pole type)

-F VDE standard

-R AS standard

-Q BS standard

-H GB standard

-N NBR standard

-HE English menu language

/B5 Built-in printer

/C20 IRIG function

/G5 Simultaneous harmonic measurement

/M1*1

/M2*1

50 M point/CH memory extension100 M point/CH memory extension

/P4 4 CH probe power output

/PD 4 CH sensor power output

Product name Model Suffix code Description

Voltage Module 760811 *2 Necessary to order the same number as that of the 760812/760813 Current Modules at the same time

Current Module 760812 *2 Necessary to order the same number of that of the 760811 Voltage Modules at the same time

760813 *2 Necessary to order the same number of that of the 760811 Voltage Modules at the same time The 760813 is direct current input only.

Auxiliary (AUX) Module

760851 Can measure the sensor signals of torque and rotation speed on 2 channels

*1 Selection of both /M1 and /M2 is not available for one main frame. The standard memory length is 10

M points/CH.

*2 The power value will be calibrated using a pair of Voltage (760811) and Current (760812/760813)

modules, therefore an equal quantity of these must be ordered together.

Product name Model Suffix code Description

Power Viewer Plus

760881 Dedicated PC application software for PX8000. It is a waveform data analysis software

<Cautions regarding the installation of modules and their location>

- The PX8000 has a maximum of 8 slots for installing modules.

- It is required to equip the PX8000 main frame with at least one Voltage Module and one Current Module

in slots 1 and 2 to create one Power Measurement Element. The PX8000 can be equipped with a

maximum of three additional Power Measurement Elements.

- When modules are ordered with the PX8000 main frame, the modules are factory installed in the main

frame up to a combined maximum of 4 power measurement elements and auxiliary modules. Priority is

given to the installation of power measurement elements.

- The location of modules can be changed by the customer. However, slot 1 must be always containing a

Voltage Module and slot 2 must always contain a Current Module.

- Power values are calibrated using one Voltage Module and one Current Module, so the same number of

these modules must be ordered together. In the case of service, repair or re-calibration, both modules

must be sent together to the service department.

- Up to 3 Auxiliary (AUX) Modules can be installed in odd numbered slot only (3, 5 and 7). Odd numbered

slots (3, 5 and 7) are also used to install additional Voltage Modules, and even numbered slots (4, 6 and

8) for additional Current Modules.

Torque/rotation speedVoltage/currentTemperature

Vibration

Specifications PX8000 Model and Suffix Codes

32

Dig

ital P

ower

Ana

lyze

rs

Digital Power Analyzers

751552Current Clamp-on Probe, AC 1000 Arms (1400 A Peak)

Measurement bandwidth: 30 Hz to 5 kHz Basic accuracy: ± 0.3% of reading Maximum allowable input: AC 1000 Arms

1400 Apk (AC) Current output type: 1 mA/A

To connect this probe to the WT series, you need the Model 758921 (Fork terminal adapter) and Model 758917 (Measurement lead set) accessories sold separately. For details, please see the Power Meter Accessories Catalog (Bulletin CT1000-00E).

751522 / 751524 AC/DC Current Sensor Unit. DC, up to 100 kHz, up to 1000 A peak

Large current measurement: DC: 0 to 1000 A / AC: 1000 A peak

Wide measurement frequency range: DC to 100 kHz (-3 dB)

High-precision fundamental accuracy: +/- (0.05% of rdg* + 40 μA)

Superior noise withstanding ability and CMRR characteristic due to optimized casing design

Calibration enabled in combination with WT Series

758917 758921

Accessory for Digital Power Meters and Power Analyzer

Accessories for Digital Power meters and Power Analyzers

Current Probe 751552

Current Sensor Unit 751522 / 751524

Wide Variety of precision Current Sensors for broad applications

AC/DC Current Sensor CT60/CT200/CT1000

CT60/CT200/CT1000AC/DC Current Sensors, DC, up to 800 kHz, up to 1000 A peak

Rated Current CT60 DC: 0 to 60 A, AC 60 A peak CT200 DC: 0 to 200 A, AC 200 A peak CT1000 DC: 0 to 1000 A, AC 1000 A peak

Frequency bandwidth CT60 DC to 800 kHz (-3 dB) CT200 DC to 500 kHz (-3 dB) CT1000 DC to 300 kHz (-3 dB)

Measurement Accuracy DC, 50/60 Hz: ± (0.05% of reading + 30 μA)

Power Supply Voltage ± (15 V + 5%)Bulletin CT1000-00E

Bulletin CT1000-00E

Bulletin CT1000-00E

751522 : For Single-Phase

751524 : For Three-Phase

33

Dig

ital P

ower

Ana

lyze

rs

Digital Power Analyzers

Communication functions supported by WTViewer 760122

Model number GP-IB Serial (RS-232) Ethernet USB

WT1800

WT500

: Supported (by WT as standard) : Supported (by WT as an option) : Not supported (by WT)

PC-based Control and Data Acquisition

4 units synchronization

WTViewer is a software application that allows you to load numeric and waveform data mea-

sured with the WT1800 High performance Power Analyzer, or WT500 Power Analyzer to a PC

via GP-IB, or USB (for WT1800/WT500) communications. It also lets you view the waveform

data, and analyze and save the numeric data.

WTViewer

760122

Main Features of WTViewer Numeric, waveform, harmonic, and trend displays Manual save function: With one click you can save only desired data at the right timing.

Data conversion to CSV: You can save waveforms, numeric data, and screen images to a PC.

You can control multiple WT series units of the same specifications from a PC. Note: The functionality differs slightly depending on the model. For details, please

refer to the specifications of your desired model.

Power Consumption Measurement Software

Free Software

The IEC62301 Ed 2.0 is a reference standard in the EN 50564: 2011 Directive. This soft-ware corresponds to a test method of those two standards.

Allows you to acquire the necessary data such as a power value with simple opera-tions such as just pressing the Start button.

Allows you to print out a report on the measurement results.

(The free software can be downloaded from Yokogawa’s website)

Power Consumption Measurement Software

File conversion function

WT1800

Maximum connections

FTP server/client function

GP-IB connection

1 to 4 units Not available

USB communication

1 to 4 units Not available

Ethernet communication

1 to 4 units Available

WT500

Maximum connections

FTP server

function

GP-IB connection

1 to 4 units Not available

Ethernet communication

1 to 4 units Available

USB communication

1 to 4 units Not available

GP-IB

(WT1800/WT3000E/WT310E)

RS-232

(WT3000E/WT310E)

Ethernet

(WT1800/WT3000E/WT310E)

USB

(WT1800/WT3000E/WT310E)

WT3000E

Example of a printed report

Example of an initial setup screen

Example of a screen to set the measurement conditions

Example of a measurement screen

WT Series Accessory Software 760122 and Power Consumption Measurement Software

WT1800

WT310E

FTP function Command monitor

34

Dig

ital P

ower

Ana

lyze

rs

Digital Power Analyzers

WT Series Accessory Software 761922 IEC regulation software

Harmonic/Flicker Measurement Software

761922

Support for IEC Standards Testing

Example of a printed report

AC Power Supply

WT3000E Precision Power Analyzer

Recommended model:

WT3001E-2A0-30A1-x/G6/FL

Reference ImpedanceNetwork

GP-IB or Ethernet

Less than 20 A single phase

Example of a measurement screen

Launcher screen

Example of an initial setup screen

AC Power Supply

WT3000E Precision Power AnalyzerRecommended model:

      WT3003E-2A0-30A3-x/G6/FQ/FL* The external sensor input of the WT3000E is used.

Reference Impedance Network

GP-IB or Ethernet

More than 20 A single phase

Current transducerpower supply Shunt resistor

Current sensor

A special order model is available that includes a current transducer and shunt resistor set.

*You need to purchase the power supply and cable separately.

C

Allows you to judge high current equipment with input current of 16 A or more per phase (IEC61000-3-11/-3-12)

Support for the method that does not consider interharmonics in the window of 16 cycles specified in IEC61000-4-7

Best-in-class high-precision current and voltage measurements (also allows you to calculate the limits of the standard)

All Judgment graph display shows a list of all the measurement results in a time series by order.

Allows you to measure harmonics for up to 24 hours, so capable of measuring equip-ment that needs more than one hour for one cycle.

Continuous data acquisition at a measurement interval of 200 ms ensures continuous measurement over a long period of time with no missing data

Support for the standard tests of single- and three-phase equipment

35

Dig

ital P

ower

Ana

lyze

rs

Digital Power Analyzers

WT30

00E

WT18

00

WT50

0

WT31

0E/W

T330E

Product Part No. Description

1:1 BNC safety adapter lead

701901 1000 Vrms-CAT II, 1.8 m longSafety BNC (male) to safety banana (female) use in combination with 701959, 701954, 758921, 758922 or 758929

• • • •Measurement leads

758917 Two leads in a set. Use 758917 in combination with 758922 or 758929.Total length: 75 cmRating: 1000 V, 32 A

• • • • •Small alligator adapters

758922 For connection to measurement leads (758917). Two in a set.Rating: 300 V • • • • •

Large alligator adapters

758929 For connection to measurement leads (758917). Two in a set.Rating: 1000 V • • • • •

Safety terminal adapter set

758923 Spring-hold type. Two adapters in a set.

• • • • •Safety terminal adapter set

B8213ZD Screw-fastened adapters for voltage input. Two adapters in a set. 1.5 mm Allen wrench for tightening is required. • • • • •

Safety terminal adapter set

B8213ZA Screw-fastened adapters for current input of PX8000. Two adapters in a set. Allen wrench for tightening is required. •

Fork terminal adapter

758921 Two adapters (red and black) to a set. Used when attaching banana plug to binding post. • • • •

Conversion adapter

758924 For conversion between BNC and female banana plug

• • • •Conversion adapter

366971 9-pin/25-pin conversion adapter

•External sensor cable

B9284LK For the external input of the WT series. Length: 50 cm • • • • •

BNC cable 366924 BNC cable BNC–BNC, 1 m

• • • •BNC cable 366925 BNC cable BNC–BNC, 2 m

• • • •26 pin cable 705926 For/DA4 and/DA12 option

•Current sensor cable

A1559WL Cable length 3 m

•Current sensor cable

A1560WL Cable length 5 m

•Shunt resistor box A1323EZ 5 ohm ±0.05% for CT1000

•Shunt resistor box A1325EZ 20 ohm ±0.02% for CT200 and CT60

•Rack mounting kit 751535-E4 For EIA

• • •Rack mounting kit 751535-J4 For JIS

• • •Rack mounting kit 751533-E2 For WT310E/WT310EH EIA standalone installation

•Rack mounting kit 751533-J2 For WT310E/WT310EH JIS standalone installation

•Rack mounting kit 751534-E2 For WT310E/WT310EH EIA connected installation

•Rack mounting kit 751534-J2 For WT310E/WT310EH JIS connected installation

•Rack mounting kit 751533-E3 For WT332E/WT333E EIA standalone installation

•Rack mounting kit 751533-J3 For WT332E/WT333E JIS standalone installation

•Rack mounting kit 751534-E3 For WT332E/WT333E EIA connected installation

•Rack mounting kit 751534-J3 For WT332E/WT333E JIS connected installation

Digital Power Analyzers Accessories List Accessories List

PX8000

36

Gen

erat

ors,

Sou

rces

,M

anom

eter

s et

c.

Generators, Sources, Manometers etc.

Higher Accuracy — The New Advanced DC Voltage/Current Source

DC Voltage/ Current Source GS200

Functions and Specifications

Functions

The GS200 generates high accuracy, high stability, high resolution, and

extremely low-noise DC voltage and current signals that are required for

many applications.

• Voltage source up to ±32 V and current source up to ±200 mA

• 5 1/2-digit, ±120,000-count output resolution

• Voltage and current simple monitoring feature (optional)

• Programmable output up to 10,000 points

• Built-in USB mass storage device

• Channel expansion through synchronous operation

Voltage and Current Source Range

The GS200 can perform four-quadrant operation by operating as a current

source or a current sink in the range of ±30 V and ±200 mA. When the

GS200 is sinking current, it can operate over the exact same range as when

it is operating as a current source. You can use the GS200 not just as a

highly accurate voltage source but also as a highly accurate constant-current

electronic load.

-30 V 30 V

-200 mA

200 mA

Source Sink

Sink Source

Voltage

Current

The monitoring feature can be used to:

• Check that current is flowing.

• Check and inspect current consumption

• Log fluctuations in the load current

• Record I-V characteristics GS200

Vcc application

Load current measurement

GS200 Model and Suffix Codes

Model Suffix Code Description

GS210 DC voltage/current source (front panel output terminals)

GS211 DC voltage/current source (rear panel output terminals)

Supply voltage -1 100 VAC, 50/60 Hz

-4 120 VAC, 50/60 Hz

-7 230 VAC, 50/60 Hz

Power cord -D UL/CSA standard

-F VDE standard

-R AS standard

-Q BS standard

-H GB standard

Options /MON Monitoring function

/C10 Ethernet interface function

USB STORAGEDrag & Drop

Drag & Drop

USB Source

• Voltage source

Range : 10 mV, 100 mV, 1 V, 10 V, 30 V (Use a highly

accurate voltage divider at 10 mV and 100 mV

ranges)

Maximum output : ±200 mA (at 1 V, 10 V, and 30 V ranges)

• Current source

Range : 1 mA, 10 mA, 100 mA, 200 mA

Maximum output : ±30 V

• Program Feature

Maximum number of steps

: 10,000

Trigger source : Internal timer (0.1s resolution), External,

Step input, measurement end

Monitoring (option)

Function : Voltage (during current generation),

Current (during voltage generation)

Integration time : 1 to 25 PLC (Power Line Cycle)

Trigger source : Internal timer (0.1 s resolution), READY,

Communication and Immediate

Delay : 0 to 999,999 ms (1 ms resolution)

Maximum storage : 10,000 points

External Input and Output

Input signal : TRIG IN, OUTPUT IN

Output signal : TRIG OUT, OUTPUT OUT, READY OUT

Connector : RJ-11 connector

BNC connector (Select any one of the signals for

both the input and output)

Input and output level : TTL

Minimum pulse width : 10 μs

Interface

• GP-IB interface

• USB interface

• Ethernet interface (option) 100BASE-TX/10BASE-T

General Specifications

• Display : 256 × 64 dot vacuum fluorescent display

• External dimensions : Approx. 213 (W) × 88 (H) × 350 (D) mm

(excluding protrusions)

• Weight : Approx. 5 kg

37

Gen

erat

ors,

Sou

rces

,M

anom

eter

s et

c.

Generators, Sources, Manometers etc.

Multi Channel Source Measure Unit GS820

Highly Accurate 2-Channel Voltage/Current Source Measure Unit

Features

The GS820 is a highly accurate and highly functional 2-channel

programmable DC voltage/current source that incorporates voltage/current

generation and measurement functions.

• Isolated 2-channel source and measurement function

• Basic accuracy : ±0.02% (DC voltage source)

• 1 pA resolution at extremely small current range 200 nA

• Generate arbitrary waveforms consisting of up to 100,000 points at 100-μs

intervals

• Channel expansion through master-slave synchronization link

• Fast test speeds

• 16-bit digital I/O (model 765602/765612)

Source and Measurement Range

Four-quadrant operation consisting of source operation (current source)

and sink operation (current sink) is available. The output and measurement

resolutions are 5.5 digits. Two models are available for your application.

18 V range model (765601/02)

Voltage ranges: 200 mV/2 V/7 V/18 V

Maximum output:

±3.2 A (at an output voltage of ±7 V

or less)

±1.2 A (at an output voltage of ±18 V

or less)

Current ranges: 200 nA/2 μA/20 μA/200 μA/

2 mA/20 mA/200 mA/1 A/3 A

Maximum output: ±18 V (at an output current of ±1.2 A or less)

±7 V (at an output current of ±3.2 A or less)

50 V range model (765611/12)

Voltage ranges:

200 mV/2 V/20 V/50 V

Maximum output:

±1.2 A (at an output

voltage of ±20 V or less)

±0.6 A (at an output

voltage of ±50 V or less)

Current ranges: 200 nA/2 μA/20 μA/200 μA/2 mA/

20 mA/200 mA/0.5 A/1 A

Maximum output: ±50 V (at an output current of ±0.6 A or less)

±20 V (at an output current of ±1.2 A or less)

Model and Suffix code

USB STORAGEDrag & Drop

Drag & Drop

USB

Source and Measurement Functions• Voltage source and current measurement (VS&IM)• Current source and voltage measurement (IS&VM)• Voltage source (VS)• Current source (IS)• Voltmeter (VM)• Ammeter (IM)• Resistance meter (IS&VM)SourceFunction: Voltage or currentMode: DC or pulse (pulse width: 50 μs to 3,600 s)Sweep mode: Linear, logarithmic or program (up to 100,000 steps)Trigger source: External or internal timers 1 and 2 (period: 100 μs to 3,600 s)Sweep start source: External or internal timers 1 and 2 (period: 100 μs to 3,600 s)Source delay: 15 μ to 3,600 sResponse characteristics: Normal or stableMeasurementFunction: Voltage, current, auto, voltmeter mode, ammeter mode or resistance meter modeIntegration time: 0.001 to 25 PLC (Power Line Cycle)Trigger source: External or internal timers 1 and 2 (period: 100 μs to 3,600 s)Measure delay: 0 μs to 3,600 sMeasurement data storage: Up to 100,000 data pointsAverage: Moving average (average count: 2 to 256)Voltage sense: Two-wire system or four-wire systemAuto zero: Measure the internal zero reference every measurement and correct the measured valueNULL computation: Computes the difference with respect to the current measuredvalue or user-defined valueUser-defined computation: Computes user-defined equations in real-timeExternal I/O and Communication Interface• BNC I/O• Digital I/O D-Sub 15-pin (model 765601/11) Half-pitch 50-pin (model 765602/12)• I/O for synchronized Operation RJ-11 connector 6-pin, BNC connector• GPIB• RS232• USB• Ethernet 100 BASE-TX/10 BASE-TDisplay 256 × 64 dot VFDDimensions Approx. 213(W) × 132(H) × 450(D) mmWeight Approx. 8 kg

Functions

Model Suffix Code Discription

765601GS820 Multi Channel Source Measure Unit 18 V range/2-bit digital I/O model

765602GS820 Multi Channel Source Measure Unit 18 V range/16-bit digital I/O model

765611GS820 Multi Channel Source Measure Unit 50 V range/2-bit digital I/O model

765612GS820 Multi Channel Source Measure Unit 50 V range/16-bit digital I/O model

Power cord

-D UL/CSA standard, PSE compliant

-F VDE standard

-R AS standard

-Q BS standard

-H GB standard

-N NBR standard

1.2 A

1.2 A

7 V7 V

3.2 A

3.2 A

18 V18 V

Voltage

Current

Sink

Source

Source

Sink

0.6 A

0.6 A

20 V20 V

1.2 A

1.2 A

50 V50 V

Voltage

Current

Sink

Source

Source

Sink

38

Gen

erat

ors,

Sou

rces

,M

anom

eter

s et

c.

Generators, Sources, Manometers etc.

Combines High Accuracy and High Speed in a Single Unit

The GS610 is a highly accurate and highly functional programmable

voltage/current source that incorporates voltage/current generation and

measurement functions. The maximum output voltage and current are

110 V and 3.2 A, respectively. Evaluation of over a wide range of basic

electrical characteristics is possible, because the GS610 can operate as a

current source or a current sink.

• Source and sink operation up to 110 V/3.2 A (four-quadrant operation)

• Basic accuracy: ±0.02% *1

• Sweep output at up to 100 μs intervals

• Comes with abundant sweep patterns (linear, logarithmic, and arbitrary)

• Stores up to 65,535 points of source measure data in the internal memory

• Easy file operation with the USB storage function

• Remote control and FTP using Web server function (Optional)

*1: DC voltage generation

Features

Voltage/Current Generation and Measurement Range

Four-dimensional operation with source operation (current source) and

sink operation (current sink) is possible at up to 110 V, 3.2 A, and 60 W.

The output and measurement resolutions are 5.5 digits.

Voltage generation/measurement range: 200mV to 110 V

Current generation/measurement range: 20 μA to 3.2 A

Maximum output current:

±3.2 A (at an output voltage of ±12 V or less)

±2 A (at an output voltage of ±30 V or less)

±1 A (at an output voltage of ±60 V or less)

±0.5 A (at an output voltage of ±110 V or less)

3.2

2.0

1.0

0.5

-0.5

0 12-12 30-30 60-60 110-110

-1.0

-2.0

-3.2

Voltage (V)

Current (A)

Source

Source

Sink

Sink

Source Measure Unit GS610

USB STORAGEDrag & Drop

Drag & Drop

USB

Model and Suffix code

Functions

Model Suffix Codes Description

765501 GS610 Source Measure Unit

Power cord

-D UL/CSA standard

-F VDE standard

-R AS standard

-Q BS standard

-H GB standard

Option /C10 Ethernet interface

Function

• Generation

Generation function : Voltage or current

Generation mode : DC or pulse

Sweep mode : Linear, logarithmic or program (up to 65,535

steps)

• Measurement

Measurement function : DC voltage, DC current and resistance

Measurement data storage : Up to 65,535 data points

Average : Block average or moving average

(Specified count: 2 to 256)

• Trigger

Trigger mode : Internal, external and immediate

• Time setting

Pulse width : 100 μs to 3,600 s, 1 μs resolution

Period time : 1 ms to 3,600 s, 1 μs resolution

(during source and measure operation)

100 μs to 3,600 s, 1 μs resolution

(during source-only operation)

Source delay : 1 μs to 3,600 s, 1 μs resolution

Measurement delay : 1 μs to 3,600 s, 1μs resolution

Integration time : 250 μs, 1 ms, 4 ms, 16.6 ms/20 ms,100 ms,

200 ms

(auto detect from the power supply frequency

when the power is turned ON for 16.6 ms/20 ms)

• Computation function

Operators: +[addition], -[subtraction], *[multiplication], /[division] and

^ [exponentiation]

Functions: ABS(), EXP(), LN(), LOG(), SQRT(), SIN(), COS(), TAN(),

ASIN(), ACOS(), ATAN(), SINH(), COSH(), TANH(),

RAND()

External Input/Output

• Synchronization signal input/output (TRIG, SWEEP, CTRL IN and

OUT) (BNC)

• External input/output (D-Sub 15-pin)

• GP-IB interface

• RS-232 interface

• USB interface

• Ethernet interface (option) 100BASE-TX/10BASE-T

Internal memory

ROM : 4 MB Area for storing setup and output pattern files

RAM : 4 MB Area for storing the measured results

(cleared when the power is turned OFF)

Display : 256 × 64 dot vacuum fluorescent display

External dimensions : Approx. 213 (W) × 132 (H) × 400 (D) mm

(excluding protrusions)

Weight : Approx. 7 kg

39

Gen

erat

ors,

Sou

rces

,M

anom

eter

s et

c.

Generators, Sources, Manometers etc.

GS Series Accessory Software 765670 Curve Tracer Software for the GS series

Features

Simple system configuration, easy connection, compact and light

This system is configured by connecting the GS series Source Measure Unit

to a PC that contains the 765670 Curve Tracer Software via USB.

You can perform high speed, high-accuracy curve tracing despite its compact

size, light weight, and simple system configuration.

Real-time, High-Speed Drawing

The GS series is high-speed communication and sweep features allow high-

speed graph update rate up to 25 pages/s(GS820).

You can use the real-time curve tracer with comfort.

Field of Applications

• Discrete semiconductors such as transistors and diodes

• Analog ICs such as voltage regulators and op- amps

• MOS logic and other digital ICs

• LEDs and other optical devices

• Solar battery cells

Drawing Speed (times/s; reference values)

Plot PointsModel Number

GS610 GS820

20 20 25

50 10 16

100 5 11

200 3 6

Measurement conditions: Using Core2Duo CPU, 1.5 GHz, USB 2.0, and LabVIEWMeasurement integration time: 0.001 PLC for GS820 / 250 μs for GS610

http://tmi.yokogawa.com/products/generators-sources/

source-measure-units/765670-curve-tracer-software/

• Graph drawing:

Voltage vs. current, voltage vs. voltage, gain vs. voltage, voltage vs. timestamp,

current vs. voltage, current vs. current, gain vs. current, current vs. timestamp

Sweep axis: Voltage source or current source

Measurement axis: Voltage measurement or current

measurement

Parameter: Voltage source or current source

Sweep shape: Ramp (linear or log), triangle (linear or log), rectangle

Sweep points: 5, 10, 20, 50, 100, 200, 1000

Scaling: Auto scale or fixed scale

Averaging count: 2 to 100

• Analysis feature:

Cursor, zoom & scroll, reference curve designation

• File operations:

CSV data storage and loading, graphic image storage, panel image storage,

setup storage and recall

Specifications

Product Overview

This product is a high-speed, high-accuracy real-time I-V curve tracer that

consists of the GS series Source Measure Unit and the 765670 Curve Tracer

Software. It is particularly well-suited to DC parametric tests of minute

signals.

Examples of Measurements of Characteristics

FET VDS-ID characteristics

G

S

D

AVGS

Connection diagram

Measurement results

0 250m 750m 1 1.25 1.5 1.75 2 2.25 2.5 2.75 3 3.25 3.5 3.75 4 4.25 4.5 4.75 5

Sweep (V)

Measu

re (

A)

8.5m

8.5m

7.5m

7m

6.5m

6m

5.5m

5m

4.5m

4m

3.5m

3m

2.5m

2m

1.5m

1m

500

0

0 V-0.1 V-0.2 V-0.3 V

VDS

ID

Channel 1V source

Channel 2V sweep

I measurement

VGS

System configuration illustration

USB

GS820 PC

USB

USB

GS610 PC

40

Gen

erat

ors,

Sou

rces

,M

anom

eter

s et

c.

Generators, Sources, Manometers etc.

DC calibrator for temperature, voltage, and current

Features

Main specification

Precision DC Calibrator 2553A

Model and Suffix code

Main specification

The 2553A outputs DC voltage in the range of ±32 V and DC current in the

range of ±120 mA. In addition to being able to calibrate analog meters, the

2553A can calibrate thermometers and temperature controllers that utilize a

thermocouple or RTD.

• High accuracy DC voltage : ±75 ppm (0.0075%) DC current : ±120 ppm (0.012%)• High stability : ±15 ppm (0.0015%) / h• Low noise : 2 μVrms• High resolution : 5.5 digits• Intuitive operation by dials• 10 types of thermocouple and RTD Pt100• User defined temperature calibration• 3 RJC modes• Calibration by temperature value

Voltage, current generation

Range Source range Resolution

10 mV ±12.0000 mV 100 nV

100 mV ±120.000 mV 1 μV

1 V ±1.20000 V 10 μV

10 V ±12.0000 V 100 μV

30 V ±32.000 V 1 mV

1 mA ±1.20000 mA 10 nA

10 mA ±12.0000 mA 100 nA

30 mA ±32.000 mA 1 μA

100 mA ±120.000 mA 1 μA

RangeAccuracy (1 year)

± (ppm of setting + μV or μA)

Stability (1 hour)± (ppm of setting + μV or μA)

10 mV 60 + 4 20 + 3

100 mV 60 + 4 20 + 3

1 V 60 + 15 5 + 10

10 V 60 + 150 5 + 100

30 V 60 + 450 5 + 300

1 mA 80 + 0.04 5 + 0.015

10 mA 100 + 0.5 5 + 0.15

30 mA 100 + 1.5 10 + 0.9

100 mA 100 + 5 10 + 3

Calibration by temperature value2553A

2553A

120.0˚C

120˚C

Temperature generation for Thermocouple

Setting temperature : Accuracy for 1 year (±°C)

R S B J T

-50°C: 1.10 -50°C: 1.03 400°C: 1.00 -210°C: 0.25 -250°C: 0.72

0°C: 0.80 0°C: 0.75 600°C: 0.70 -100°C: 0.11 -200°C: 0.29

100°C: 0.55 100°C: 0.56 1000°C: 0.50 0°C: 0.08 -100°C: 0.16

600°C: 0.40 400°C: 0.47 1200°C: 0.44 1200°C: 0.15 100°C: 0.10

1600°C: 0.40 1600°C: 0.44 1820°C: 0.44 400°C: 0.09

1768°C: 0.45 1768°C: 0.51

E K N C A

-250°C: 0.50 -250°C: 0.94 -240°C: 1.00 0°C: 0.30 0°C: 0.34

-200°C: 0.20 -200°C: 0.30 -200°C: 0.44 200°C: 0.26 100°C: 0.29

-100°C: 0.10 -100°C: 0.15 -100°C: 0.21 600°C: 0.25 600°C: 0.28

0°C: 0.07 0°C: 0.11 0°C: 0.16 1000°C: 0.30 1600°C: 0.47

1000°C: 0.12 800°C: 0.15 800°C: 0.15 2000°C: 0.51 2500°C: 0.79

1300°C: 0.21 1300°C: 0.20 2315°C: 0.70

3 RJC modesINT: Detect temperature of output terminal as compensation valueEXT: Detect compensation value by sensor connected to RJC terminal

MAN: Input compensation value

Temperature generation for RTD

Type Source range ResolutionAccuracy (1 year)

Pt100 -200.0 to 850.0°C 0.1°C ±0.15°C

Resistance generation

Range Source range ResolutionAccuracy (1 year)

± (ppm of setting +Ω)

400 Ω 18.00 to 400.00 Ω 0.01 Ω 75 + 0.015

Interface : USB

: Ethernet

: GPIB

Warm-up time : Approx. 30 minutes

Operating environment : Temperature 5 to 40 °C

: Humidity 20 to 80% RH

Storage environment : Temperature -15 to 60 °C

: Humidity 20 to 80% RH

Operating Height : 2000 m or less

Operating Attitude : Horizon

Rated power supply voltage : 100 to 120 VAC/200 to 240 VAC

Allowable power supply voltage fluctuation range

: 90 to 132 VAC/180 to 264 VAC

Rated power supply frequency : 50/60 Hz

Allowable power supply frequency fluctuation range

: 48 to 63 Hz

Max. power cunsumption : 30 VA

Withstand voltage : Between power and case 1500 VAC 1 min.

Dimensions : 213(W) × 132(H) × 300(D) mm

Weight : Approx. 3 kg

Model Suffix code Description

2553A Precision DC Calibrator

–VA Version A

–UC Deg C

–UF Deg C and F

–D UL/CSA standard, PSE

–F VDE standard

–R AS standard

–Q BS standard

–H GB standard

–N NBR standard

41

Gen

erat

ors,

Sou

rces

,M

anom

eter

s et

c.

Generators, Sources, Manometers etc.

AC Standard Source with Improved Performance and Usability

AC Voltage Current Standard 2558A

Functions and Specifications

Features

Functions and Specification

2558A Model and Suffix Codes

2558A

Stability : ±(20 ppm of setting + 30 ppm of range)/hDistortion factor Voltage : 0.07% or less Current : 0.18% or lessFrequency range Internal : 50 / 60 / 400 Hz / VAR VAR: 40 to 1000 Hz (0.001 Hz resolution) External : EXT1/EXT2 (Use the terminals for synchronized operations) FREQUENCY METER : MIN/MAX 20 to 1000 Hz (0.001 Hz resolution) Sweep, output divider and deviation functions are used

for the frequency.Sweep Target : Voltage / Current / Frequency Speed : Approx. 8/16/32/64 sec. selectableOutput divider Target : Voltage / Current / Frequency Denominator range : m4 to 15 Numerator range : n0 to 15 (n ≤ m)Deviation Target : Voltage / Current / Frequency Variable range: ±20.00% Operation : Two dials

Resolution of the first dial: 0.2% of the main setting

Resolution of the second dial: 0.01% of the main setting

Deviation preset: OFF / 0 / 2% / 5%Output terminalType Voltage : Plug-in terminal (safety terminal) Current : Binding post Selectable LO terminal to earth or floating Max. floating voltage to earth: 12 VpkInterface : USB interface (for PC connection) : Ethernet : GP-IB interface (optional)Warm-up time : Approx. 30 minutesOperating environment Temperature : 5 to 40ºC Humidity : 20 to 80%RH (no condensation)Rated power supply voltage : 100 to 120 VAC / 200 to 240 VACRated power supply frequency : 50/60 HzMax. power consumption : 200 VAWeight : Approx. 20 kgDimensions : 426(W) × 132(H) × 400(D) mm

The wide output ranges of 1.00 mV to 1200.0 V AC and 1.00

mA to 60.00 A AC mean that the 2558A is the instrument

of choice for the cost effective calibration of AC analog

meters.

• Wide output range AC voltage : 1.00 mV to 1200.0 V AC current : 1.00 mA to 60.00 A• High accuracy AC voltage : 0.04% AC current : 0.05%• High output stability : ±50 ppm/h• Wide frequency range : 40 to 1000 Hz Accuracy : ±50 ppm• Intuitive operation with dials for setting each digit• Sweep function : 8/16/32/64 sec. (selectable)• Output divider function (Divided output of the main setting)• Direct readout of the deviation (Displays the deviation from the main

setting)

Output

Range Output Range Guaranteed Accuracy Range

100 mV 0 to 144.00 mV 1 to 120.00 mV

1 V 0 to 1.4400 V 0.01 to 1.2000 V

10 V 0 to 14.400 V 0.1 to 12.000 V

100 V 0 to 144.00 V 1 to 120.00 V

300 V 0 to 432.0 V 3 to 360.0 V

1000 V 0 to 1440.0 V 10 to 1200.0 V

100 mA 0 to 144.00 mA 1 to 120.00 mA

1 A 0 to 1.4400 A 0.01 to 1.2000 A

10 A 0 to 14.400 A 0.1 to 12.000 A

50 A 0 to 72.00 A 0.5 to 60.00 A

Accuracy (180 days) 1 to 10% output of range ±(% of range) Voltage 50/60 Hz : 0.013 40 to 400 Hz : 0.015 400 to 1000 Hz : 0.030 Current 50/60 Hz : 0.014 40 to 400 Hz : 0.016 400 to 1000 Hz : 0.032 10 to 120% output of range ±(% of setting + % of range) Voltage 50/60 Hz : 0.03 + 0.01 40 to 400 Hz : 0.05 + 0.01 400 to 1000 Hz : 0.10 + 0.02 Current 50/60 Hz : 0.04 + 0.01 40 to 400 Hz : 0.06 + 0.01 400 to 1000 Hz : 0.12 + 0.02

Model Suffix Code Description

2558A AC Voltage Current Standard

Power cord -D UL/CSA standard, PSE

-F VDE standard

-R AS standard

-Q BS standard

-H GB standard

-N NBR standard

Option /C1 GP-IB interface

42

Gen

erat

ors,

Sou

rces

,M

anom

eter

s et

c.

Generators, Sources, Manometers etc.

High-voltage and High-current Output and Intuitive Operation

Features

Main Specifications

Precision DC Calibrator 2560A

Model and suffix codes

Main Specifications

The 2560A can accurately and stably generate DC voltage of up to 1224 V

and DC current of up to 36.72 A. In addition to voltage and current meters,

the 2560A can calibrate thermometers and temperature controllers that use

thermocouples and RTDs.

• Wide output range DC voltage : ±1224 V DC current : −12.24 A to +36.72 A• High accuracy DC voltage : ±50 ppm (0.005%) DC current : ±70 ppm (0.007%)• High stability DC voltage : ±10 ppm (0.001%)/h DC current : ±20 ppm (0.002%)/h• High resolution : 5.5 digits, ±120,000 count display 6.5 digits, ±1,200,000 count display• Intuitive operability with dials for each digit• Sweep, output division, deviation, scale setting• Ten types of thermocouples, and RTD Pt100• User-defined temperature calibration, three RJC modes

Voltage and current generating parts

Range Output range Resolution

100 mV ±122.400 mV 1 μV

1 V ±1.22400 V 10 μV

10 V ±12.2400 V 100 μV

100 V ±122.400 V 1 mV

1000 V ±1224.00 V 10 mV

100 μA ±122.400 μA 1 nA

1 mA ±1.22400 mA 10 nA

10 mA ±12.2400 mA 100 nA

100 mA ±122.400 mA 1 μA

1 A ±1.22400 A 10 μA

10 A ±12.2400 A 100 μA

30 A 0 to +36.720 A 1 mA

RangeAccuracy (one year)

± (ppm of setting + V or A)

Stability (1 h)

± (ppm of setting + V or A)

100 mV 60 + 4 μV 20 + 3 μV

1 V 55 + 15 μV 5 + 5 μV

10 V 55 + 150 μV 5 + 50 μV

100 V 55 + 1.5 mV 5 + 500 μV

1000 V 55 + 15 mV 5 + 5 mV

100 μA 150 + 20 nA 50 + 5 nA

1 mA 70 + 30 nA 5 + 15 nA

10 mA 70 + 300 nA 5 + 150 nA

100 mA 90 + 3 μA 10 + 1.5 μA

1 A 350 + 70 μA 25 + 25 μA

10 A 380 + 1.2 mA 50 + 500 μA

30 A 540 + 1.8 mA 70 + 1.2 mA

Bulletin: 2560A-01EN

Temperature generation for thermocouples

Setting temperature: Accuracy for one year (±°C)

R S B J T

−50°C: 1.10 −50°C: 1.03 400°C: 1.00 −210°C: 0.25 −250°C: 0.72

0°C: 0.80 0°C: 0.75 600°C: 0.70 −100°C: 0.11 −200°C: 0.29

100°C: 0.55 100°C: 0.56 1000°C: 0.50 0°C: 0.08 −100°C: 0.16

600°C: 0.40 400°C: 0.47 1200°C: 0.44 1200°C: 0.15 100°C: 0.10

1600°C: 0.40 1600°C: 0.44 1820°C: 0.44 400°C: 0.09

1768°C: 0.45 1768°C: 0.51

E K N C A

−250°C: 0.50 −250°C: 0.94 −240°C: 1.00 0°C: 0.30 0°C: 0.34

−200°C: 0.20 −200°C: 0.30 −200°C: 0.44 200°C: 0.26 100°C: 0.29

−100°C: 0.10 −100°C: 0.15 −100°C: 0.21 600°C: 0.25 600°C: 0.28

0°C: 0.07 0°C: 0.11 0°C: 0.16 1000°C: 0.30 1600°C: 0.47

1000°C: 0.12 800°C: 0.15 800°C: 0.15 2000°C: 0.51 2500°C: 0.79

1300°C: 0.21 1300°C: 0.20 2315°C: 0.70

Three RJC modesINT: Uses a temperature measured at the output terminal as a compensation value.EXT: Uses a temperature detected by a sensor connected to the RJ sensor terminal as a compensation value.

MAN: Uses a value input manually as a compensation value.

Temperature generation for RTDs

Type Output range ResolutionAccuracy(one year)

Pt100 −200.0 to 850.0°C 0.1°C ±0.12°C

Resistance generation

Range Output range ResolutionAccuracy (one year)

± (ppm of setting + Ω)

400 Ω 1.00 to 400.00 Ω 0.01 Ω 75 + 0.005

Interface : USB interface (PC connection)

: Ethernet

: GP-IB

Warm-up time : Approx. 30 min

Operating environment : Temperature 5 to 40ºC

Humidity 20 to 80%RH

(no condensation)

Rated power supply voltage : 100 to 120 V AC/200 to 240 V AC

Rated power supply frequency : 50/60 Hz

Max. power consumption : Approx. 200 V A

Dimensions : 426 (W) × 177 (H) × 400 (D) mm

Weight : Approx. 13 kg

Model code Suffix code Description

2560A Precision DC Calibrator

–VA Version A

–UC Deg C

–UF Deg C and F

–D UL/CSA standard, PSE compliant

–F VDE standard

–R AS standard

–Q BS standard

–H GB standard

–N NBR standard

43

Gen

erat

ors,

Sou

rces

,M

anom

eter

s et

c.

Generators, Sources, Manometers etc.

Bring new value by the multiple display formats and high sampling speed

Features

Digital Multimeter DM7560

Model and suffix codes

Functions and Specifications

The DM7560 provides high sampling rates of up to

30 kS/s with high accuracy and provides all the basic

functions of a Digital Multimeter. With its capability to

monitor transitional voltage variations, it can be applied

to a wide range of applications.

• Multiple display formats• High speed data logging (Maximum 30 kS/s)• High capacity internal memory up to 100 k points• Offline browsing to provide trend and histogram analysis• Productivity improvement by varied interfaces

DC voltage (DCV) Range: 100 mV to 1000 V

DC current (DCI) Range: 1 mA to 3 A

AC voltage (ACV) Range: 100 mV to 750 V

AC current (ACI) Range: 1 A to 3 A

Resistance measurement (2 WΩ/4 WΩ) Range: 100 Ω to 100 MΩContinuity test (CONT) Resistance range: 1 kΩDiode Measuring current: Approx. 1 mA

Temperature measurement (TEMP, TC) Thermocouple type: R/K/T/J/E

Temperature measurement (TEMP, RTD) Resistance temperature

detector: Pt100, Jpt100

Frequency measurement (FREQ) Range: 3 Hz to 300 kHz

Advange points

Comprehensive observation by multiple display formats High-speed data logging

Model code Suffix code Description

DM7560 Digital Multimeter

Supply voltage -1 100 VAC, 50/60 Hz

-3 115 VAC, 50/60 Hz

-6 220 VAC, 50/60 Hz

-8 240 VAC, 50/60 Hz

Power cord -D UL/CSA standard, PSE compliant

-F VDE Standard

-R AS Standard

-Q BS Standard

-H GB Standard

-N NBR Standard

Options /C1 GP-IB Interface*

/C2 LAN & RS-232 Interface*

/CMP DIO Interface

* Only one can be selected.

-1.5

-1

-0.5

0

0.5

1

1.5

-1.5

-1

-0.5

0

0.5

1

1.5

Fast signal change can be measured exactly with high sampling rate.

The case of 10 ms pulse width, 2 Vpp measurementwith DC voltage measuring function.

Sample of 1 kS/s

Sample of 30 kS/s

Annunciator

Indicates the status of the instrument

status by icons.

Secondary display (examples)

Analog meter display

Statistics display

LIMIT judgment display

Primary display (examples)

Trend display (Plots time domain variation)

Histogram display (Plots distribution)

Arc scale meter display (Shows values

intuitively)

44

Gen

erat

ors,

Sou

rces

,M

anom

eter

s et

c.

Generators, Sources, Manometers etc.

Temperature Measuring Instrument 7563

7563Digital Thermometer, 6.5 Digits

• Thermometer has a 6.5-digits display Twelve types of TC’s and four types of RTD’s• Basic accuracy in temperature

measurement: 0.006% (TC)• Basic accuracy in DCV measurement: 0.0045% (2000 mV range)• Basic accuracy in resistance measurement: 0.006% (2000 Ω range)• Number of sampling times: up to 100 times/s (4.5 digits)

7563 Specifications

Maximum display: ±1999999Resolution: Voltage 100 nV Resistance 100 μΩ Thermocouple 0.1°C RTD 0.01°CReference junction compensation accuracy: ±0.2°CVarious computation functionsSoftware calibration functionMemory function• Internal memory up to 1000 data items• IC memory up to 8000 data itemsCommunication function: GP-IBAnalog output (optional): code /DA specifiedPower consumption: 20 VAExternal dimensions: 213 (W) × 88 (H) × 350 (D) mmWeight: approx. 3 kg

Precision Digital Thermometer

Digital Resistance Meter 7556

7556

• High-speed measurement (2.8 ms)• High accuracy: ±(0.006% of reading + 3 digits)• High resolution: 5.5 digits• Wide range: 1 Ω range to 100 MΩ range• Full remote control through serial (RS-232) or GP-IB interface• Software-based calibration function• Advanced contact check function

7556 Specifications

Range: 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ, 1 MΩ, 10 MΩ, 100 MΩ

Resolution: Deviation display 755601: -99.99% to 19.99% or -99.9% to 199.9% (selectable) 755611: -99.999% to 19.999% or -99.99 to 199.99% (selectable) Absolute value display 755601: 100 μΩ (at 1 Ω range) 755611: 10 μΩ (at 1 Ω range)Measurement time: Normal mode: 60 Hz power supply: 19.9 ms 50 Hz power supply: 23.2 ms Fast mode: 5.7 ms High-speed mode: 2.8 msAccuracy (at 1 kΩ range, 23±5°C in normal mode) 755601: ±(0.015% of reading + 1 digit) 755611: ±(0.006% of reading + 3 digits)Contact check function Check level: 1 Ω to 30 Ω (Selectable) Execute checks before or after measurement (selectable) Check current: 50 mA Contact check error message with display panel and handler interface Measured current abnormality detection function (Detect measured current abnormality caused by a

contact error)Comparator function (both Hi and Lo) Deviation setting range 755601: -9.99% to 9.99% or -99.9% to 99.9% (selectable) 755611: -9.999% to 9.999% or -99.99% to 99.99% (selectable) Absolute value setting range 755601: 0.0000 Ω to 1.2000 Ω 755611: 0.00000 Ω to 1.20000 Ω

The 7556 is designed to be mounted on a taping machine.

* When you use the 7556 for any purpose other than a production line, you need to be careful.

Please read the specifications carefully.

High-Speed Digital Resistance Meter for Production Line of Fixed Chip Resistors

45

Gen

erat

ors,

Sou

rces

,M

anom

eter

s et

c.

Generators, Sources, Manometers etc.

Functions and Specifications

FG410/FG420 Models and Suffix Codes

Related Software

Easily Generate Basic, Application Specific and Arbitrary Waveform

Features

The FG400 Arbitrary/Function Generator provides a wide

variety of waveforms as standard and generates signals

simply and easily. There are one channel (FG410) and

two channel (FG420) models. As the output channels are

isolated, an FG400 can also be used in the development

of floating circuits. (up to 42 V)

• 0.01 μHz to 30 MHz output (sine wave)• 20 Vp-p output/open, 10 Vp-p output/50 Ω• Arbitrary waveform generation function• 3.5-inch color display• Up to 6 units (12 channels) can be synchronized• A variety of sweeps, modulations and functions• Parameter-variable waveforms

Model Suffix code Description

FG410 Arbitrary /Function Generator, 1-Channel Model

FG420 Arbitrary /Function Generator. 2-Channel Model

Power cord -D UL/CSA standard, PSE

-F VDE standard

-R AS standard

-Q BS standard

-H GB standard

-N NBR standard

FG420

This software allows you to display the waveforms and measurement results on a PC for the data measured with Yokogawa’s DLM/DL/SL series. It allows you to clip part of a waveform and generate an arbitrary waveform with the FG400.

This software supports the arbitrary waveform function of the FG400. It allows you to edit waveforms and transfer data to the FG400. It also makes it easy to work on a pre-installed waveform to generate an arbitrary waveform.

This software supports the sequence function of the FG400 that outputs different waveforms sequentially. It controls the edit, transfer, and execution of sequence data. Complex programs can also be created easily.

XviewerLITE Arbitrary Waveform Editor Sequence Editor

• Number of channels FG410: 1-channel model FG420: 2-channel model• Output waveforms Sine, square, pulse, ramp, DC, parameter-variable

waveform (25 types), noise (Gaussian distribution), arbitrary waveform

• Oscillation modes Continuous, modulation, sweep, burst, sequence• Frequency Sine 0.01 μHz to 30 MHz Square/pulse 0.01 μHz to 15 MHz Ramp/parameter-variable waveform 0.01 μHz to 5 MHz• Arbitrary waveform Waveform length 4 K to 512 K words or 2 to

10,000 control points• Modulation type FM, FSK, PM, PSK, AM, DC offset, PWM• Sweep type Frequency, phase, amplitude, DC offset, duty• Synchronization Sync operation is possible. Up to 6 units can be of multiple units connected with BNC cables in the form of master/ slave connections, using the frequency reference output and external 10 MHz frequency reference input• Power supply AC 100 V to 230 V ± 10% (250 V max.) 50 Hz/60 Hz ± 2 Hz• Power consumption FG410 50 VA or less FG420 75 VA or less• Weight Approx. 2.1 kg• Dimensions 216 (W) × 88 (H) × 332 (D) mm

Arbitrary/Function Generator FG400 Series

46

Gen

erat

ors,

Sou

rces

,M

anom

eter

s et

c.

Generators, Sources, Manometers etc.

Pressure Standard MC100

MC100Pneumatic Pressure Standard

• High accuracy: ±0.05% of full scale• Output ranges and resolution 0 to 200 kPa (resolution 0.01 kPa) 0 to 25 kPa (resolution 0.001 kPa)• Functions useful for instrument calibration Divider output, auto-step output, and sweep

output• Excellent temperature coefficient Zero point: ±0.003% of full scale/°C Span: ±0.002% of full scale/°C

MC100 Series Specifications

• Supply pressure 0 to 200 kPa range model: 280 kPa ±20 kPa 0 to 25 kPa range model: 50 kPa ±10 kPa• Accuracy ±0.05% of full scale (at 23°C ±3°C)• Output noise: ±0.02% of full scale• Effect of mounting orientation Forward/backward incline of 90° 0 to 200 kPa range model: ±0.01% of

full scale 0 to 25 kPa range model:

Pneumatic Pressure Standard

±0.1% of full scale Sideways incline of 30° 0 to 200 kPa range model: ±0.2% of

full scale 0 to 25 kPa range model: ±2.5% of

full scale• Pressure display units (selectable): kPa, kgf/cm2, mmH2O, mmHg kPa, psi, inH2O, inHg• External dimensions: 213 (W) × 132 (H) × 400 (D) mm• Weight: approx. 9.5 kg

47

Gen

erat

ors,

Sou

rces

,M

anom

eter

s et

c.

Generators, Sources, Manometers etc.

Manometers MT210/MT210F/MT220/MT10

MT210FDigital Manometer

• High accuracy: ±(0.01% of reading + 3 digits) (130 kPa range gauge model)

• Select from three measurement modes: normal speed, medium speed, and high speed

• D/A conversion output, comparator output, and external trigger input (optional)

• Both gases and liquids measurable• External attachable battery pack (optional)

MT210F Series Specifications

• Measuring range (gauge pressure: positive) 0 to 10 kPa, 130 kPa, 700 kPa and 3000 kPa Measuring range (gauge pressure: negative) -80 to 0 kPa, -10 to 0 kPa• Measuring range (absolute pressure) 0 to 130 kPa abs• Accuracy (for 0 to 10 kPa range model) ±(0.01% of reading + 0.015% of full

scale) (at positive pressure)• Response time (0 to 130 kPa range model,

at high speed mode) 50 msec max.• Readout update interval (at medium and

high speed mode) 100 msec• Resolution 0 to 10 kPa range model: 0.0001 kPa 0 to 130 kPa range model: 0.001 kPa 0 to 700 kPa range model: 0.01 kPa 0 to 3000 kPa range model: 0.01 kPa• Maximum allowable input (for gauge

pressure positive) 0 to 10 kPa range model: 500 kPa gauge 0 to 130 kPa range model: 500 kPa gauge 0 to 700 kPa range model: 3000 kPa gauge 0 to 3000 kPa range model: 4500 kPa gauge• Pressure display units (selectable): psi, inH2O, inHg, kPa, kgf/cm2, mmH2O, mmHg• External dimensions: 213 (W) × 132 (H) × 350 (D) mm• Weight Approx. 6.5 kg (0 to 130 kPa range model)

Fast Response Digital Manometer

MT210Digital Manometer

• High accuracy: ±(0.01% of reading + 3 digits) (130 kPa range gauge model)

• A wide range pressures, from a low differential pressure of 1 kPa to a high gauge pressure of 3000 kPa, and absolute pressure of 130 kPa

• D/A conversion output, comparator output, and external trigger input (optional)

• Both gases and liquids measurable• External attachable battery pack (optional)

MT210 Series Specifications

• Measuring range (gauge pressure: positive) 0 to 10 kPa, 130 kPa, 700 kPa and 3000 kPa Measuring range (gauge pressure: negative) -80 to 0 kPa, -10 to 0 kPa• Measuring range (absolute pressure) 0 to 130 kPa abs• Measuring range (differential pressure) 0 to 1 kPa, 10 kPa, 130 kPa and 700 kPa• Accuracy (for 0 to 10 kPa range model) ±(0.01% of reading + 0.015% of full

scale) (at positive pressure)• Resolution 0 to 1 kPa range model: 0.00001 kPa 0 to 10 kPa range model: 0.0001 kPa 0 to 130 kPa range model: 0.001 kPa 0 to 700 kPa range model: 0.01 kPa 0 to 3000 kPa range model: 0.01 kPa• Maximum allowable input (for gauge

pressure positive) 0 to 10 kPa range model: 500 kPa gauge 0 to 130 kPa range model: 500 kPa gauge 0 to 700 kPa range model: 3000 kPa gauge 0 to 3000 kPa range model: 4500 kPa gauge• Pressure display units (selectable): psi, inH2O, inHg, kPa, kgf/cm2, mmH2O,

mmHg• External dimensions: 213 (W) × 132 (H) × 350 (D) mm• Weight Approx. 6.5 kg (0 to 130 kPa range model)

Precision Digital Manometer

Digital Manometer For Efficient Field Calibration Handheld Digital Manometer

MT10Mini-Manometer

• Compact and lightweight (approx. 700 g), battery-operated

• High reliability (silicon resonant sensor adopted)

• Accuracy: ±(0.04% of rdg + 0.03% of FS) for 130 kPa model

• Three models for 130 kPa, 700 kPa, and 3000 kPa (gauge pressure)

• Data hold function• RS-232-C interface• Comes with carrying case

MT220Digital Manometer

• The de facto standard of field celibrators for pressure and ditferential pressure transmitters

• High accuracy: ±(0.01% of reading + 3 digits) (130 kPa range gauge model)

• DCV/DCA measurement function (DMM function)

• 24 VDC power supply for driving the transmitter

• % display, error display, and measured data memory

• D/A conversion output, comparator output, and external trigger input (optional)

• Both gases and liquids measurable• External attachable battery pack (optional)

MT10 Series Specifications

• Type of pressure: gauge• Three measuring ranges 0 to 130 kPa, 0 to 700 kPa, and 0 to 3000 kPa• Measurement display range: -2.5 to 110% of FS• Accuracy: 0 to 130 kPa range model ±(0.04% of rdg + 0.03% of FS) 0 to 700 kPa and 0 to 3000 kPa range

models ±0.1% of FS• Resolution 0 to 130 kPa range model: 0.01 kPa 0 to 700 kPa range model: 0.1 kPa 0 to 3000 kPa range model: 1 kPa• Maximum allowable input 0 to 130 kPa range model: 500 kPa 0 to 700 kPa range model: 1000 kPa 0 to 3000 kPa range model: 4500 kPa• Effect of temperature Zero: ±0.02% of FS/10°C or less Span: ±0.02% of FS/10°C or less• Pressure display units (specified at shipment) kPa, kgf/cm2, mmH2O, mmHg, Psi, inH2O, inHg• External dimensions: Approx. 72 (W) × 174 (H) × 60 (D) mm (excluding input connections)• Weight: Approx. 700 g (including battery)

MT220 Series Specifications

• Measuring range (gauge pressure: positive) 0 to 10 kPa, 130 kPa, 700 kPa and 3000 kPa Measuring range (gauge pressure: negative) -80 to 0 kPa, -10 to 0 kPa• Measuring range (absolute pressure) 0 to 130 kPa abs• Accuracy (for 0 to 10 kPa range model) ±(0.01% of reading + 0.015% of full

scale) (at positive pressure)• Resolution 0 to 10 kPa range model: 0.0001 kPa 0 to 130 kPa range model: 0.001 kPa 0 to 700 kPa range model: 0.01 kPa 0 to 3000 kPa range model: 0.01 kPa• Maximum allowable input (for gauge

pressure positive) 0 to 10 kPa range model: 500 kPa gauge 0 to 130 kPa range model: 500 kPa gauge 0 to 700 kPa range model: 3000 kPa gauge 0 to 3000 kPa range model: 4500 kPa gauge• Pressure display units (selectable): psi, inH2O, inHg, kPa, kgf/cm2, mmH2O, mmHg• Measurement range of DCV/DCA

measurement function 0 to ±5.25 V 0 to ±21 mA• Accuracy of DCV/DCA measurement

function (6 months after calibration) ±(0.05% of reading + 3 digits)• 24 VDC output 24 ± 1 VDC, 30 mA max.• External dimensions: 213 (W) × 132 (H) × 350 (D) mm• Weight Approx. 7.0 kg (0 to 130 kPa range model)

48

Optic

al M

easu

ring

Inst

rum

ents

Optical Measuring Instruments

High Performance Optical Spectrum Analyzers Meeting Measurement Needs in a Broad Range of Applications

Optical Spectrum Analyzer AQ6370 Series

AQ6370 Series of Optical Spectrum Analyzers Common Specifications

• Best-in-class optical performance

· High wavelength resolution and high dynamic range

· High sensitivity

· Free-space optical input

• Excellent measurement throughput

· High-speed spectrum measurement

· High-speed remote interface

· High resolution and wide bandwidth batch measurement

• More user-friendly

· USB interface available

For mouse, keyboard, and external storage devices such as a memory

device and hard disc drive (HDD).

· Trace zooming function

· More than 10 waveform analysis functions available

• Support for creating an automatic measurement system

· GP-IB, RS-232C, and Ethernet interfaces available

· Support for the remote commands and formats of the AQ6317 series

· Macro programming function available

• Wavelength calibration reference light source or alignment light

source available

• AQ6370 Viewer emulation and remote control software (option)

Three Models Converting a Wide Wavelength from 350 nm to 3400 nm

AQ6370D (600 to 1700 nm)

Standard model optimized to the wavelengths often used in telecommunication

applications

AQ6373B (350 to 1200 nm)

Model for short-wavelength including visible light (VIS)

AQ6375B (1200 to 2400 nm)/AQ6376 (1500 to 3400 nm)

Model for emerging applications in exNIR+MWIR regions

Features

Short Wavelength

Long Wavelength

400 600 1000 1200 1500 1700 2000 2400 3400wavelength

(nm)

Main Optical Applications and Wavelength Bands Used

Visible Light Range

AQ6373B AQ6376

Medical Treatment – Biology – Information & Communication – Environmental Analysis – Sensing – Material Processing, etc.

AQ6375B

AQ6370D

Optical Applications

Today, optical technology is used in a

wide variety of applications, which include

biomedical application and environmental

measurement, as well as information

and communication, where demand for

broadband connectivity is growing rapidly,

driven by the popularity of the Internet, IP

telephony, and video streaming. Yokogawa’s

optical spectrum measurement technology

contributes to the development of such

optical applications.

Items Specifications

Electrical interface GP-IB, RS-232, Ethernet, USB, SVGA output, Analog output port, Trigger input port, Trigger output port

Remote control *1 GP-IB, RS-232, Ethernet (TCP/IP), AQ6317 series compatible commands (IEEE488.1) and IEEE488.2

Purge gas input/ou tput terminals *3 Outer diameter 1/4 inch, nylon tube

Data storageInternal storage: 512 MBytes, Internal memory: 64 Traces, 64 programs, 3 template lines, External storage: USB storage (memory/HDD), FAT32 format File types: CSV (text), Binary, BMP, TIFF

Display *2 10.4-inch color LCD (Resolution: 800 × 600)

Dimensions Approx. 426 (W) × 221 (H) × 459 (D) mm (Excluding protector and handle)

Mass AQ6370D/AQ6373B: Approx. 19 kg, AQ6375B/AQ6376: Approx. 23 kg

Power requirements 100 to 240 V AC, 50/60 Hz, approx. 100 VA

Environmental conditionsPerformance guarantee temperature: +18 to +28°C, Operating temperature: +5 to +35°C, Storage temperature: −10 to +50°C, Humidity: 20 to 80%RH (no condensation)

RoHS EN50581

Recommended calibration period 1 year

*1: Some AQ6317 series commands may not be compatible due to changes in specifications or functions. *2: Liquid crystal display may include a few defective pixels (within 0.002% with respect to the total number of pixels including RGB).

There may be a few ixels on the liquid crystal display that do not emit all the time or remains ON all the time. These are not malfunctions. *3: AQ6375B and AQ6376 *4: With built-in calibration light source

Environmental Measurement ApplicationInformation & Communication ApplicationBiomedical Application

Example of a Configuration of a Scanning Confocal Microscope System

Cell

Fluorescence from a cell

Camera

Laser

Fluorescence

Microscope

Model CSU10

Confocal Scanner Unit

Z-axis Drive

Image Monitor

Image Processing

Unit

High Performance Filter

TX Terminal

λ1

λ2

λ3

λ4

λ5

λn

λ1

λ2

λ3

λ4

λ5

λ6

Optical AMP

OADM

RX Terminal

Optical Fiber

DEMUXMUX

100 km~ 100 km~ 100 km~

DWDM Transmission System

Optical AMP

OADM

Amplified

Example of a Configuration of a Dense Wavelength Division Multiplexing (DWDM) Optical Communication System

Example of a Configuration of Simultaneous Multi-Wavelength Measurement of Gases Using the CDRS Technique

Detecting Gases Using Gas-SpecificLight Absorption Characteristics

CRDS Optical

Coupler

Laser λ1

Circulator

Fiber Grating

WDM

Coupler

Fiber Loop

λ1

λ2

Laser λ2

OpticalFiber

OpticalFiber

OpticalFiber

• Evaluating the performance of high performance filers for a visible light laser and fluorescence extraction

• Evaluating the performance of optical components, such as a laser, optical multiplexer, optical demultiplexer and optical amplifier, as well as the system as a whole

• Evaluating the performance of optical components such as a laser and grating

• Evaluating the light absorption characteristics of gases

49

Optic

al M

easu

ring

Inst

rum

ents

Optical Measuring Instruments

Redefining Optical Spectrum Measurement Excellence

• World Class Optical Performance & Flexibility High wavelength accuracy: ±0.01 nm High close-in dynamic range: 78 dB typ. Single and multimode fiber test capability (up to GI 62.5/125 μm)• Improved Measurement Throughput Double-speed mode Fast measurement and fast data transfer• Enhanced User Friendliness USB for Mouse, keyboard, and external storage devices Bright 10.4” LCD Trace zoom capability Various built-in analysis functions• Expedites Development of Automated Test Systems Supports GP-IB, RS-232C, and Ethernet interfaces Compatible with SCPI and supports AQ6317 series remote commands Built-in simple macro programming function• Includes Wavelength Calibration Source (Optional)• AQ6370 Viewer: Emulation/Remote control software (Optional)

Features

Example of the dynamic range

Peak±1.0 nm, Resolution setting 0.05 nm, High dynamic mode: ON, High performance model

DWDM signal measurement

DWDM channels allocated at 50 GHz spac-ing can be measured and analyzed.

World-class optical performance Enhanced User Friendliness

click

drag

Mouse

Keyboard

Memory

HDD

USB interface

Supports mouse, keyboard, and external storage devices.

Trace zoom function

Enlarges a designated area

78dB

Optical Spectrum Analyzer AQ6370D

Enhanced functions

• Data logging function The Data Logging function records analysis results such as WDM

analysis (OSNR, optical signal/noise ratio), distributed feedback laser diode (DFB-LD) analysis, and multi-peak measurements at up to 10,000 points per channel with time stamps. Recorded data can be displayed in table and graphical forms.

• Advanced marker function The Advanced Marker function adds markers to obtain the power

density and the integrated power of a designated spectrum.• Gate sampling function The Gate Sampling function facilitates the recirculating loop testing of

optical transmission systems. • Resolution calibration function The Resolution Calibration function is used to calibrate the noise

equivalent bandwidth with an external light source.

Data Logging display Advanced marker display

Main Specifications

Items Specifications

Spec-code Standard (-10) High performance (-20)

Wavelength range *1 600 to 1700 nm

Span *1 0.1 nm to 1100 nm (Full span), and 0 nm

Wavelength accuracy *1, *2, *5 ±0.02 nm (1520 to 1620 nm) ±0.01 nm (1520 to 1580 nm), ±0.02 nm (1580 to 1620 nm)

Wavelength resolution setting *1, *2 0.02, 0.05, 0.1, 0.2, 0.5, 1 and 2 nm

Number of sampling 101 to 50001, AUTO

Level sensitivity setting NORM_HOLD, NORM_AUTO, NORMAL, MID, HIGH1, HIGH2 and HIGH3

High dynamic mode SWITCH (Sensitivity: MID, HIGH1-3)

Level sensitivity *2, *3, *4, *7 −90 dBm (1300 to 1620 nm), −85 dBm (1000 to 1300 nm), −60 dBm (600 to 1000 nm) (Sensitivity: HIGH3)

Maximum input power *2, *3 +20 dBm (Per channel, full range)

Level accuracy *2, *3, *4, *6 ±0.4 dB (1310/1550 nm, Input level: −20 dBm, Sensitivity: MID, HIGH1-3)

Dynamic range *1, *2, *8 Resolution: 0.02 nm 55 dB (Peak ±0.2 nm), 37 dB (Peak ±0.1 nm) 58 dB (Peak ±0.2 nm, Typ. 60 dB), 45 dB (Peak ±0.1 nm, Typ. 50 dB)

Resolution: 0.1 nm 57 dB (Peak ±0.4 nm), 40 dB (Peak ±0.2 nm) 60 dB (Peak ±0.4 nm, Typ. 67 dB), 45 dB (Peak ±0.2 nm, Typ. 50 dB)

Stray-light suppression ratio *7, *10 73 dB 76 dB (Typ. 80 dB)

Applicable fiber SM (9.5/125 μm), GI (50/125 μm, 62.5/125 μm)

Optical connector Optical input: AQ9447 ( ) Connector adapter (option) required.Calibration output: AQ9441 ( ) Universal adapter (option) required. ( ) Connector type FC or SC

Built-in calibration light source *11 Wavelength reference source (For optical alignment and wavelength calibration)

Sweep time *1, *7, *9 NORM_AUTO: 0.2 sec, NORMAL: 1 sec, MID: 2 sec, HIGH1: 5 sec, HIGH2: 20 sec, HIGH3: 75 sec

Warm-up time Minimum 1 hour (After warming up, optical alignment adjustments required.)

*1: Horizontal scale: Wavelength display mode.

*2: With 9.5/125 μm single mode fiber with a PC type connector, after 1 hour of warm-up, after optical alignment

with built-in reference light source or a single longitudinal mode laser (wavelength 1520 to 1560 nm, peak

level ≥ −20 dBm, level stability ≤ 0.1 dBpp, and wavelength stability ≤ ±0.01 nm).

*3: Vertical scale: Absolute power display mode, Resolution setting: ≥ 0.05 nm, Resolution correction: OFF.

*4: With 9.5/125 μm single mode fiber (B1.1 type defined on IEC60793-2, PC polished, mode field diameter: 9.5

μm, NA: 0.104 to 0.107).

*5: After wavelength calibration with built-in reference light source or a single longitudinal mode laser (wavelength

1520 to 1560 nm, peak level ≥ −20 dBm and absolute wavelength accuracy ±0.003 nm).

*6: Temperature condition changes to 23 ±3°C at 0.05 nm resolution setting.

*7: High dynamic mode: OFF, Pulse light measurement mode: OFF, Resolution correction: OFF.

*8: 1523 nm, High dynamic mode: SWITCH, Resolution correction: OFF

*9: Span: ≤ 100 nm, Number of sampling: 1001, Average number: 1.

*10: With He-Ne laser (1523 nm), 0.1 nm resolution setting, 1520 nm to 1620 nm except for peak wavelength ±2 nm.

*11: Option.

“Typical” or “typ.” in this document means “Typical value”, which is for reference, not guaranteed specification.

50

Optic

al M

easu

ring

Inst

rum

ents

Optical Measuring Instruments

The OSA for emerging applications in exNIR + MWIR regions

• Unparalleled Performance

Wavelength range: 1200 to 2400 nm (AQ6375B)

1500 to 3400 nm (AQ6376)

Wavelength resolution setting: 50 pm to 2 nm (AQ6375B)

0.1 to 2 nm (AQ6376)

Wide measurement level range: -70 to +20 dBm (AQ6375B)

-65 to +13 dBm (AQ6376)

Close-in dynamic range: 55 dB

• Greater Efficiency

High speed measurement

Fast command processing and data transfer

• Support Multimode Fiber

Free-space optical input

• Intuitive Easy Operation

Mouse & keyboard operation

Trace zoom function

• Easy Calibration

Built-in calibrator

• AQ6375&76 Viewer: Emulation/Remote control software (Optional)

Features

2010 nm DFB-LD with AQ6375B(Res: 0.050 nm, Span: 20 nm)

3270 nm DFB-LD with AQ6376(Res: 0.1 nm, Span: 20 nm)

Main specifications

Unparalleled Optical Performance

Items Specifications

Model AQ6375B AQ6376

Wavelength range *1 1200 to 2400 nm 1500 to 3400 nm

Span *1 0.5 nm to 1200 nm (Full span), 0 nm 0.5 nm to 1900 nm (Full span), 0 nm

Wavelength accuracy *1,*2,*5 ±0.05 nm (1520 to 1580 nm),

±0.10 nm (1580 to 1620 nm),

±0.50 nm (Full range)

±0.50 nm (Full range)

Wavelength repeatability *1,*2 ±0.015 nm (1 min.)

Wavelength resolution setting *1,*2 0.05, 0.1, 0.2, 0.5, 1 and 2 nm 0.1, 0.2, 0.5, 1 and 2 nm

Minimum sampling resolution *1 0.002 nm 0.003 nm

Number of sampling 101 to 50001, AUTO

Level sensitivity setting NORM_HOLD, NORM_AUTO, NORMAL, MID, HIGH1, HIGH2 and HIGH3 (Only High dynamic mode (/CHOP) in HIGH1-3)

Level sensitivity *2,*3,*6 −70 dBm (1800 to 2200 nm),

−67 dBm (1500 to 1800 nm, 2200 to 2400 nm),

−62 dBm (1300 to 1500 nm) (Sensitivity: HIGH3)*4

−65 dBm (1500 to 2200 nm),

−55 dBm (2200 to 3200 nm),

−50 dBm (3200 to 3400 nm) (Sensitivity: HIGH3)

Maximum input power *2,*3 +20 dBm (Per channel, full wavelength range) +13 dBm (Per channel, full wavelength range)

Maximum safe input power *2,*3 +25 dBm (Total input power) +20 dBm (Total input power)

Level accuracy *2,*3,*4,*8 ±1.0 dB (1550 nm, input level: −20 dBm, Sensitivity: MID, HIGH1-3) ±1.0 dB (1550 nm, input level: −20 dBm, Sensitivity: HIGH1-3)

Level linearity *2,*3 ±0.05 dB (Input level: −30 to +10 dBm, Sensitivity: HIGH1-3) ±0.2 dB (Input level: −30 to +10 dBm, Sensitivity: HIGH1-3)

Polarization dependence *2,*3,*8 ±0.1 dB (1550 nm) —

Dynamic range *1,*2 45 dB (Peak ±0.4 nm, Resolution: 0.05 nm),

55 dB (Peak ±0.8 nm, Resolution: 0.05 nm)

(1523 nm, Sensitivity: HIGH1-3)

40 dB (Peak ±1 nm, Resolution: 0.1 nm),

55 dB (Peak ±2 nm, Resolution: 0.1 nm)

(1523 nm, Sensitivity: HIGH1-3)

Applicable fiber SM (9.5/125 μm), GI (50/125 μm, 62.5/125 μm)

Optical connector Optical input: AQ9447 ( ) Connector adapter (option) required.

Calibration output: AQ9441 ( ) Universal adapter (option) required.

( ) Connector type FC or SC

Built-in calibration light source Wavelength reference source (For optical alignment and wavelength calibration)

Sweep time *1,*6,*7 NORM_AUTO: 0.5 sec, NORMAL: 1 sec, MID: 2 sec, HIGH1: 20 sec

Warm-up time Minimum 1 hour (After warming up, optical alignment adjustment with built-in light source required.)

*1: Horizontal scale: Wavelength display mode.

*2: With 9.5/125 μm single mode fiber, after 2 hours of warm-up, after optical alignment with built-in reference light source, when the purge gas is not used.

*3: Vertical scale: Absolute power display mode, Resolution setting: ≥ 0.1 nm (AQ6375B)/ ≥ 0.2 nm (AQ6376).

*4: With 9.5/125 μm single mode fiber (B1.1 type defined on IEC60793-2, PC polished, mode field diameter: 9.5 μm, NA: 0.104 to 0.107).

*5: After wavelength calibration with built-in reference light source, Sampling resolution: ≤ 0.003 nm (AQ6375B)/AUTO (AQ6376), Sensitivity: MID, HIGH1-3

*6: Pulse light measurement mode: OFF.

*7: Span: ≤ 100 nm (The AQ6376 excluding 2200 to 2220 nm), Number of sampling: 1001, Average number: 1.

*8: Temperature condition changes to 23 ±3°C at 0.1 nm resolution setting (AQ6375B only).

Measurement Example

Optical Spectrum Analyzer AQ6375B/AQ6376

SMSR44.96dB

3270.35nmSMSR56.21dB

2010.12nm

51

Optic

al M

easu

ring

Inst

rum

ents

Optical Measuring Instruments

Optical Spectrum Analyzer AQ6373B

Short Wavelength OSA 350 - 1200 nm

Applications

Main Specifications

Item Specifications

Wavelength range *1 350 to 1200 nm

Span *1 0.5 nm to 850 nm (full span), and 0 nm

Wavelength accuracy *1 ± 0.05 nm (633 nm), ± 0.20 nm (400 to 1100 nm) (after wavelength calibration with 633 nm He-Ne laser)

Wavelength resolution setting *1, *2 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10 nm (full range), and 0.01 nm (400 to 470 nm)

Minimum sampling resolution *1 0.001 nm

Number of sampling points 101 to 50001, AUTO

Level sensitivity setting NORM_HOLD, NORM_AUTO, NORMAL, MID, HIGH1, HIGH2 and HIGH3

High dynamic mode SWITCH (sensitivity setting: MID, HIGH1 to 3)

Level sensitivity *3 -80 dBm (500 to 1000 nm), -60 dBm (400 to 500 nm, 1000 to 1100 nm) (Typical, Resolution setting: ≥ 0.2 nm, Averaging: 10 times, Sensitivity: HIGH3)

Maximum safe input power *3 + 20 dBm (550 to 1100 nm), + 10 dBm (400 to 550 nm) (total input power)

Level accuracy *2 ± 1.0 dB (850 nm, Input level: -20 dBm, Resolution: ≥ 0.2 nm, Sensitivity: MID, HIGH1 to 3, SMF [MFD5 μm@850 nm, NA0.14]

Level linearity *3 ± 0.2 dB (Input level: -40 to 0 dBm, Sensitivity: HIGH1-3)

Dynamic range *1 60 dB (Peak ± 0.5 nm, Resolution: 0.02 nm, 633 nm, Sensitivity: HIGH1 to 3)

Applicable fiber SM, GI (50/125 μm, 62.5/125 μm), Large core fiber (up to 800 μm)

Optical connector FC type (optical input and calibration light source output)

Built-in calibration light source Optical alignment light source (not equipped with wavelength reference light source.)

Sweep time *1, *4 NORM_ AUTO: 0.5 sec, NORMAL: 1 sec, MID: 2 sec, HIGH1: 5 sec, HIGH2: 20 sec, HIGH3: 75 sec

Warm-up time Minimum 1 hour (after warming up, optical alignment adjustment with built-in light source is required.)

Performance and functions can be limited by type of used fiber. The specifications are only guaranteed when a single mode fiber in which light travels in single mode at the measured wavelength is used. In the case in which the measured

wavelength is less than the cut-off wavelength of the used fiber, or a multimode fiber is used, a measured spectrum may be inaccurate due to speckle noise. Please be careful especially when measuring high coherency sources like gas laser

and laser diode.

*1: Horizontal scale: Wavelength display mode.

*2: Actual wavelength resolution varies according to the measured wavelength. Actual resolution at the 10 nm resolution setting is about 8 nm at most.

*3: Vertical scale: Absolute power display mode.

*4: High dynamic mode: OFF, Pulse light measurement mode: OFF, Number of sampling points: 1001, Average number: 1, Span: ≤ 100 nm excluding 450 to 470 nm and 690 to 700 nm.

• Wavelength accuracy: ±0.05 nm

• Wavelength resolution setting: 0.02 to 10 nm

(Settable to 0.01 nm at 400 to 470 nm)

• Max. safe input power: +20 dBm

• Level sensitivity: -80 dBm

• Dynamic range: ≥60 dB

• Single-mode, multimode, and

large-core fibers

• Built-in optical alignment source

• Automatic wavelength calibration

with an external source

• Data logging function

• Built-in color analysis function

for VIS

Active optical device (semiconductor laser, fiber laser, LED)

Passive active device (filter, FBG, special optical fiber)

Support for the development of optical devices

• Medical and biological applications (medical laser treatment, DNA

analysis, laser microscope)

• Industrial equipment (laser processing, laser marking)

• Home electronics (laser projector, next-generation optical disc, LED

products)

• Measurement (LIDAR, interferometer)

• Communication (plastic optical fiber (POF) communication)

Visible LED Test

The optical spectrum of visible LEDs used in a wide variety of applications

such as lighting, indication, and measurement can be measured and

analyzed. By supporting the large core fiber input, the AQ6373B can

efficiently acquire the LED light and measure its spectrum. The standard

built-in color analysis function automatically evaluates a dominant

wavelength and XYZ color coordinates.

Higher resolution measurement is possible in 400 to 470 nm range.

Color analysis of white LED

AQ6373B

Optical fiber

Visible LED

FWHM = 0.011nm

Example of 405 nm FP-LD measurement (Resolution setting: 0.01 nm)

52

Optic

al M

easu

ring

Inst

rum

ents

Optical Measuring Instruments

High performance and cost-effective Optical Wavelength Meter

Exceeding the testing needs of optical devices and transmission systems

Model and Suffix Codes

Model Suffix Descriptions

AQ6150 AQ6150 Optical Wavelength Meter

AQ6151 AQ6151 Optical Wavelength Meter

Spec code -10 Base model

Power cord -D UL/CSA standard, and PSE standards

-F VDE standard

-R AS standard

-Q BS standard

-H GB standard

-N NBR standard

Optical connector

(Factory option)

/FC AQ9441(FC) Universal Adapter

/SC AQ9441(SC) Universal Adapter

Optical Wavelength Meter AQ6150 series

Applications

The AQ6150 series optical wavelength meter is an ideal instrument for accurately measuring the optical wavelength of optical devices and systems used in telecommunication applications from 1270 to 1650 nm. By employing a Michelson interferometer and a high speed Fast Fourier Transform (FFT) algorithm, the AQ6150 series can measure not only a single wavelength laser signal but also a multiple wavelength laser signal from a DWDM system and Fabry-Perot laser.

• Wavelength Range: 1270 to 1650 nm

• Wavelength accuracy: ±0.3 pm (AQ6151), ±1 pm (AQ6150)

• Simultaneous measurement of up to 1024 wavelengths

• Cope with modulated light and optical filter measurement

• Increase throughput with high speed measurement

• Reduce the lifetime ownership costs

• logging data function

• Add WDM (OSNR) analysis

• Abundant functions to increase work efficiency

Features

WDM system (Transmitter)

TX

TX

EDFATX

MU

X

TX

TX

λ1

λ2

λ3

λ4

λn

RX

RX

RX

DE

MU

X

RX

RX

λ1

λ2

λ3

λ4

λnλmλm

WDM system (Receiver)

Optical output of WDM system

Optical output of optical devices

(Laser/TOSA/Optical transceiver/

Optical transponder, etc.)

Input signal of

optical receiver

EDFA ROADM EDFA EDFA

Send the command to initiate

Measurement & Analysis Data transfer

SSS dSSSendSend hththe com ddmand to initiate

MMeasurem tent && Analysisy Data transfer 0.3 sec

Multi wavelength view Optical spectrum view

Other modes:Single wavelength view, Delta wavelength view, Grid view, and List view

WDM transmission systems

• Simultaneous measurement of multi channel and narrow spacing WDM system

• Precise adjustment and inspection of laser sources• Measurement of modulated signals

Lasers / optical transceivers

• Precise adjustment and inspection of tunable lasers• Modulated signal measurement of optical transceivers and transponders.• Measurement of all channels of 40 G and 100 G optical transceivers with

WDM technology. Calibration of test systems

• Calibration of optical spectrum analyzers.• Calibration of DFB lasers for optical amplifier test system.• Calibration of tunable lasers for passive component test systems.

Product Lineup

There are two models in the series. The High Accuracy AQ6151 model offers an accuracy of ±0.3 pm to meet the most demanding precision requirements.The Standard Accuracy AQ6150 offers a ± 1 pm accuracy for applications with less demanding requirements at a more affordable price.

Specifications

Increase throughput with high speed measurement

Various view modes

Both models can acquire, analyze and transfer a measurement to a PC within 0.3 seconds. This vastly improves production throughput.

Model Accuracy Key applications

AQ6150 ± 1 pmInspection of DFB-LDs, Tunable lasers, Optical transceivers.

WDM transmission systems

AQ6151 ± 0.3 pmAdjustment, characterization, and inspection of Laser chips,

Tunable lasers, WDM transmission systems, etc.

Model Accuracy Key applications

Applicable optical fiber SM (ITU-T G.652)

Wavelength range 1270 to 1650 nm

Wavelength accuracy AQ6150: ±0.7 ppm (±1 pm at 1550 nm)

AQ6151: ±0.2 ppm (±0.3 pm at 1550 nm)

Min. resolvable separation 5 GHz (40 pm at 1550 nm)

Display resolution (Wavelength) 0.0001 nm

Power accuracy ±0.5 dB (1550 nm, -10 dBm)

Linearity ±0.3 dB (1550 nm, -30 dBm or higher)

Polarization dependency ±0.5 dB (1550 nm)

Display resolution (Power) 0.01 dB

Max. number of wavelengths 1024

Min. input power -40 dBm (1270 to 1600 nm, single line input)

-30 dBm (1600 to 1650 nm, single line input)

Max. input power +10 dBm (total of all lines)

Safe max. input power +18 dBm (total of all lines)

Return loss 35 dB

Measurement time 0.3 s or less (single measurement)

Display 5.7-inch color LCD (640 × 480 dots)

Data storage Internal: 256 MB or more, External: USB

Interfaces GP-IB, ETHERNET, USB, VGA output

Remote control GP-IB, ETHERNET

Optical connector FC/PC or SC/PC (AQ9441 Universal adapter)

Dimensions Approx. 426 (W) × 132 (H) × 450 (D) mm

Mass Approx. 11 kgPlease refer to the product brochure for details.

53

Optic

al M

easu

ring

Inst

rum

ents

Optical Measuring Instruments

Build Your Own Test Configurations in Small Footprint

Applications

• Frame controllers

AQ2211 Frame controller (3 slots for modules)

AQ2212 Frame controller (9 slots for modules)

• Light source modules

AQ2200-131 Grid TLS module (C/L-band, 1 channel)

AQ2200-132 Grid TLS module (C/L-band, 2 channels)

• Sensor modules

AQ2200-215 Sensor module (+30 dBm, 970-1660 nm, 1-slot)

AQ2200-221 Sensor module (Dual sensor, 800-1700 nm, 1-slot)

• Optical attenuator modules

AQ2200-311A ATTN module [w/ Monitor output (optional)] (SMF or

MMF, 1-slot)

AQ2200-331 ATTN module [w/ built-in monitor power meter] (SMF or

MMF, 1-slot)

AQ2200-342 DUAL ATTN module [w/ built-in monitor power meter]

(SMF, 1-slot)

• Optical switch modules

AQ2200-411 OSW module (1 × 4 or 1 × 8, SMF or MMF, 1-slot)

AQ2200-412 OSW module (1 × 16, SMF, 2-slot)

AQ2200-421 OSW module (1 × 2 or 2 × 2, SMF or MMF, 1-slot)

• Modules for Optical Transceiver

AQ2200-642 Transceiver interface module (2-slot)

AQ2200-651 SG module (2-slot)

Frame and Module Lineup

• GE-PON ONU/OLT measurement system

• GE-PON optical three wavelength filter measurement

• Optical amplifier measurement system

• Optical transceiver measurement system

The AQ2200 Multi Application Test System is the ideal system for measuring and evaluating a wide range of optical devices and optical transmitters.

• Flexible and space effective

• Easy-to-View TFT color display

• Remote operation through Ethernet network

• Built-in applications

• Optical power stability measurement

• Short-term optical power fluctuation measurement

• Wide variety of plug-in modules

• Hot-swappable modules

Features

Transceiver Measurement System Optical Fiber Amplifier Measurement System

Multi Application Test System AQ2200

Rx

Transceiver(DUT)

Tx

AQ2200-331ATTN

AQ6370DOptical

Spectrumanalyzer

AQ2212 Frame controller

Tx

10 G BERT

Rx

AQ2200-221OPM

AQ2200-642Transceiver I/F

AQ2200-651SG

AQ2200-411OSW

(1 × 4)

AQ2200-215high-power OPM

AQ6370DOptical

SpectrumAnalyzer

DUT

Opticalfiber

amplifer

AQ2200-421(2/2)OSW

(1 × 2)

AQ2200-421(1/2)OSW

(1 × 2)

AQ2200-311AATTN

AQ2200-132×8

MUX

AQ2212 Frame Controller

Grid TLS

Grid TLS

Grid TLS

Grid TLS

AQ2200-342×8

DUAL ATTN

DUAL ATTN

DUAL ATTN

DUAL ATTN

The 10 Gbit/s optical transceiver modules such as XFP or SFP+ are

frequently used in transmission systems and Ethernet systems.

The measuring system for such modules requires many instruments

including power supplies, multi-meters and the signal generators to control

optical transceiver modules.

The AQ2200 Multi Application Test System allows for building a space

saving test system with a variety of plug-in modules.

An optical fiber amplifier is an

indispensable device for WDM

transmission systems. This

measurement system characterizes

gains and noise figures (NF) of the

fiber amplifier by measuring input

light to an optical fiber amplifier,

which was multiplexed using

multiple light sources, as well as

amplified output light with an optical

spectrum analyzer. A high-power sensor allows for measuring total output

power.

[Measurement items]

• Gain, NF, and total output power

AQ6370D Measurement Screen

54

Optic

al M

easu

ring

Inst

rum

ents

Optical Measuring Instruments

Model and Suffix Code

General Specifications

Display: 8.4-inch color TFT LCD Multi-touch capacitive touchscreen

Power supply: AC adapter voltage 100 to 120 VAC or 200 to 240 VAC (auto

switching) Battery(Li-ion) operation time 15 hours (Telcordia

GR-196-CORE Issue 2). 10 hours (continuous measurement)

Electrical I/F: Unit interface × 1, module interface × 1, USB 2.0 × 3,

Ethernet × 1*1, SD card slot × 1

Dimensions: 287 mm (W) × 210 mm (H) × 80 mm (D)

Weight: Approx. 2.2 kg (OTDR mainframe)*1 option

Features

The AQ7280 succeeds the high-end AQ7275 OTDR, which has been used

for the installation and maintenance of a wide range of network systems,

including core, metro, and access networks.

The AQ7280 has a best-in-class 8.4-inch capacitive touchscreen that supports

the same intuitive multi-touch functionality found in smartphones and other

handheld devices, allowing users to reposition and resize objects on the

screen. The AQ7280 also has the same operation hard keys found on the

preceding model. Users can opt to use either the touchscreen or the hard

keys.

The AQ7280 series offers remarkable flexibility and convenience with

modular measuring units that can be replaced in the field. As new measuring

units are developed to keep up with advances in optical technology, the

AQ7280 can be modified simply by replacing the measuring unit.

Specifications by Model

Optical Time Domain Reflectmeter AQ7280

OTDRunit

Number of

wavelength

Dynamic range (dB) Test application Fiber network

SM1310 (nm)

SM1383(nm)

SM1490 (nm)

SM1550 (nm)

SM1625 (nm)

SM1650 (nm)

MM 850 (nm)

MM 1300 (nm)

InstallationMaintenance

Core Metro Access PONMMfiberDark Live

AQ7282A 2 38 36

AQ7283A 2 42 40

AQ7284A 2 46 45

AQ7285A 2 50 50

AQ7283E 3 42 40 40*1

AQ7283F 3 42 40 40*1

AQ7283H 3 42 40 39 *2

AQ7284H 3 46 45 44 *2

AQ7282G 3 38 36 36

AQ7283K 4 42 38 40 40 *2

AQ7283J 4 42 39 40 40 *2

AQ7282M 2 25 27

*1: Port2, Built-in filter

*2: Using an external filter

OTDR Mainframe

Models Suffix codes Descriptions

AQ7280 AQ7280 OTDR Mainframe

Language -HJ Japanese/English

-HE English (Multi language)

-HM Chinese

-HC Chinese/English

-HK Korean/English

-HR Russian/English

Options /FST Fiber Surface Test function

/MNT Monitoring function

/SMP Smart Mapper function

/LAN Ethernet

/SB Shoulder Belt

Standard accessories; Battery pack, hand belt, user’s manual (CD-ROM), operation guide

AC adapter (Not included in AQ7280. Please order separately.)

Models Suffix codes Descriptions

739871 AC Adapter*1, *3

739872 AC Adapter*2, *3

*1: For outside the US and the countries that require CE marking.

*2: For the US and the countries that require CE marking.

*3: Used with power cord. Refer the bulletin of AQ7280 OTDR for the select.

OTDR units

Models Suffix codes Descriptions

AQ7282A 2WL 1310/1550 nm 38/36 dB

AQ7283A 2WL 1310/1550 nm 42/40 dB

AQ7284A 2WL 1310/1550 nm 46/45 dB

AQ7285A 2WL 1310/1550 nm 50/50 dB

AQ7283E 3WL 1310/1550,1625 nm 42/40, 40 dB*4

AQ7283F3WL 1310/1550,1650 nm 42/40, 40 dB

(1650 nm port is equipped with a built-in filter)

AQ7283H 3WL 1310/1550/1625 nm 42/40/39 dB

AQ7284H 3WL 1310/1550/1625 nm 46/45/44 dB

AQ7282G 3WL 1310/1490/1550 nm 38/36/36 dB

AQ7283K 4WL 1310/1490/1550/1625 nm 42/38/40/40 dB

AQ7283J 4WL 1310/1383/1550/1625 nm 42/39/40/40 dB

AQ7282M 2WL 850/1300 nm (MM) 25/27 dB

Optical

connector-USC Universal Adapter (SC)

-UFC Universal Adapter (FC)

-ULC Universal Adapter (LC)

-ASC Universal Adapter (SC Angled-PC)*1

-NUA No universal adapter

Options /PC Power Checker*1, *2

/SLS Stabilized Light Source*3

*1: Not applicable to AQ7282M

*2: Not applicable to the Port2 of AQ7283E and AQ7283F

*3: Not applicable to the wavelength 1383 nm of AQ7283J.

*4: The port for 1650 nm or 1625 nm is equipped with a built-in filter.

OPM/VLS modules

Models Suffix codes Descriptions

AQ2780 OPM Module

AQ2781 High Power OPM Module

AQ2780V OPM & VLS Module

AQ2781V High Power OPM & VLS Module

Optical

connector-SCC Universal Adapter (SC)

-FCC Universal Adapter (FC)

-LMC Ferrule Adapter (ϕ 1.25)

Models Suffix codes Descriptions

AQ4780 VLS Module

Application Software

Models Suffix codes Descriptions

735070 AQ7932 Emulation Software (Ver. 5.01 or later)

-EN English

-JA Japanese

-CH Chinese

-KO Korean

735071 AQ7940 Optical Fiber Monitoring Software (Ver. 5.01 or later)

-HE English

-HJ Japanese

735050 Additional option license for AQ7280

-FST Fiber Surface Test function

-MNT Monitoring Function

-SMP Smart Mapper Function

55

Optic

al M

easu

ring

Inst

rum

ents

Optical Measuring Instruments

MFT-OTDR AQ1200

Features

Model and suffix code

The AQ1200 is a multifunctional handheld OTDR that combines all the

necessary field test functions in one unit. It offers various functions, including

an OTDR function that features short 80 cm event dead zone, a fault locator

function that is effective in locating a fault, a loss test function (option) that

combines light sources and an optical power meter in one unit, and a visible

light source (option). You can also connect a fiber end-face inspection probe.

The AQ1200 retains the interface of the very popular AQ7252 series. So you

can use the variety of functions and the user-friendly interface.

Light source & Optical power meter option

Option Optical Power Meter (/SPM) Standard (/SLT) High power (/HLT) PON (/PPM) Stabilized Light Source (/SLS)

Optical Power meter

Wavelength setting850/1300/1310/1490/1550/1625/1650 nm, 800 to 1700 nm (1 nm steps),

or CWDM wavelength (1270 to 1610 nm 20 nm steps)1310/1490/1550 nm –

Applicable fiber SM (lTU-T G 652), GI (50/125 μm), GI (62.5/125 μm) SM (lTU-T G 652) –

Power range+10 to -70 dBm (CW)

+7 to -60 dBm (CHOP)+27 to -50 dBm (CW)

+24 to -50 dBm (CHOP)+10 to -70 dBm (CW)+27 to -50 dBm (CW)

Noise level 0.5 nW (-63 dBm, 1310 nm) 50 nW (-43 dBm, 1310 nm)0.5 nW (-63 dBrn, 1310nm)50 nW (-43 dBm, 1550nm)

Uncertainty under standard conditions

±5 % ±0.5 dB –

Readout resolution 0.01 –

Level unit Absolute: dBm, mW, μW, nW, Relative: dB –

Modulation mode CW, CHOP (270 Hz/1 kHz/2 kHz) –

Average function 1, 10, 50 and 100 times –

Light source

Wavelength (nm) –1310/1550 ±0.25 nm (AQ1200A/E, AQ1205A/E/F), 1625 ±10nm (AO1200B/E),

1625 ±25nm (AO1205E), 1650 ±5 nm, 1650 ±10 nm (AQ1200C, AQ1205F)

Optical output level (dBm)

– -3 ±1

Level stability (dB) –±0.05 (1310/1550 nm, AQ1200A/E, AQ1205A/E/F), ±0.15 (1625/1650 nm, AQ1200B/C/E, AQ1205E/F)

Modulation mode – CW, 270 Hz, 1 kHz, 2 kHz

Applicable fiber – SM (lTU-T G 652)

Memory and logging function ‒ Measurement data storage: 10 to 1000 data, Logging interval: 0.5, 1, 2, 5, or 10 sec

Auto loss test function ‒ Loss measurement with light source and optical power meter interlock

Factory Installed Options

Model Suffix codes Description

AQ1200A 1310/1550 nm

AQ1200B 1625 nm

AQ1200C 1650 nm

AQ1200E 1310/1550, 1625 nm

AQ1205A 1310/1550 nm, High Dynamic Range

AQ1205E 1310/1550 nm, 1625 nm High Dynamic Range

AQ1205F 1310/1550 nm High Dynamic Range, 1650 nm

Language

-HE English

-HC Chinese/English

-HK Korean/English

-HR Russian/English

Powercord

-D UL/ CSA standard

-F VDE standard

-R AS standard

-Q BS, Singapore standard

-H GB standard, Complied with CCC

-P EK standard (S. Korea)

-T BSMI standard

-N Brazil standard

Optical connector

-USC SC type

-UFC FC type

-ASC SC/Angled-PC type

light source &optical power meter

/SLT Stabilized light source & Standard optical power meter

/HLT Stabilized light Source & High power optical power meter

/PPM Light source & PON Power meter

/SLS Stabilized light source

/SPM Standard optical power meter

Visible light source /VLS Optical connector: 2.5 ϕ ferrule

PON measurement*1 /PN PON measurement mode

Ethernet /LAN 10BASE T/100BASE TX (PING test, Remote control)

Shoulder belt /SB Shoulder belt

AC adapter /AC1 Attach 739872 AC adapter*2

*1: Only for AQ1200A. AQ1200B/C/E and AQ1205A /E/F come equipped this function.

*2: For the US and the countries that require CE marking.Specifications

Model AQ1200A AQ1200B AQ1200C AQ1200E AQ1205A AQ1205E AQ1205F

Measured wavelength (nm)1310±20(typ)/1550±20(typ)

1625±101650±5, 1650±10

1310±20(typ)/1550±20(typ),

1625±10

1310±20(typ)/1550±20(typ)

1310±20(typ)/1550±20(typ), 1625±20(typ)

1310±20(typ)/1550±20(typ),

1650±5, 1650±10

Optical Port PORT2 PORT2, 3 PORT2 PORT2, 3

Measured fiber SM (ITU-T G.652)

Distance range(km) 0.5, 1, 2, 5, 10, 20, 50, 100, 200, 300, 400, 512 0.5, 1, 2, 5, 10, 20, 50, 100, 200, 300, 400, 512

Pulse width(ns) 3, 10, 20, 50, 100, 200, 500, 1000, 2000, 5000, 10000, 20000 3, 10, 20, 50, 100, 200, 500, 1000, 2000, 5000, 10000, 20000

Event Dead zone (typ.) 0.75 m

Attenuation Dead zone (typ.) 4 m/5 m 7 m 4 m/5 m, 7 m 4 m/5 m 4 m/5 m, 7 m

Dynamic range(dB)(typ.) 34/32 33 34 38/36,36 42/40 42/40,38 42/40,37

Loss measurement accuracy ±0.05 dB or ±0.05 dB/dB

Optical connector Universal Adapter SC, FC

Output power control – Normal/ Low – Normal/ Low

Laser safety standard Class 1M

Ethernet Interface (/LAN) option

Interface 10BASE-T/100BASE-TX

Function Ping test and remote control

Visible Light Source (/VLS) option

Optical connector 2.5 mm type ferrule

Wavelength and optical output level 650 nm± 20 nm, -3 dBm or more (peak)

Modulation mode CHOP approx. 2 Hz

Laser class 3R

56

Optic

al M

easu

ring

Inst

rum

ents

Optical Measuring Instruments

Optical Power Meter

Model AQ2170 AQ2170H AQ2180 AQ2180H

Wavelength Setting 850/1300/1310/1490/1550/1625/1650 nm 1310/1490/1550/1625/1650 nm 850/1300/1310/1490/1550/1625/1650 nm 1310/1490/1550/1625/1650 nm

Photo Detector InGaAs InGaAs

Optical FiberSM (ITU-T G.652), GI (50/125 μm),

GI (62.5/125 μm) In fiberSM (ITU-T G.652) In fiber

SM (ITU-T G.652), GI (50/125 μm),

GI (62.5/125 μm) In fiberSM (ITU-T G.652) In fiber

Optical Connector FC, SC, LC, ferrule2.5, ferrule1.25 (Standard) FC, FC, SC, LC, ferrule2.5, ferrule1.25 (Standard)

Power Range -70 to +10 dBm -50 to +26 dBm -70 to +10 dBm -50 to +26 dBm

Noise Level -60 dBm -40 dBm -60 dBm -40 dBm

Uncertainty ±5% ±5% ±5% ±5%

Display Resolution 0.01 dB (> -60 dBm), 0.1 dB (-60 dBm) 0.01 dB (> -40 dBm), 0.1 dB (-40 dBm) 0.01 dB, 0.01 dBm, 0.0001 μW

Unit ABS value: dBm, mW, μW / Relative value: dB ABS value: dBm, mW, μW / Relative value: dB

Modulation CW, CHOP (270 Hz, 1 kHz, 2 kHz) CW, CHOP (270 Hz, 1 kHz, 2 kHz)

Memory function — 999 records

I/O — USB-B (mini)

Power Source Four AAA Cell batteries Two AA Cell batteries

Battery life time 40 hours 40 hours

Dimensions (mm) Weight 63 (W) × 116 (H) × 35 (D) approx.160 g 76 (W) × 153 (H) × 43 (D) approx.280 g

Optical Light Source

Model AQ4280A AQ4280B AQ4280C

Element LD

Fiber SM (ITU-T G.652)

Wavelength 1310/1550 ± 20 nm 1310/1550±20 nm, 1490±10 nm 1310/1550±20 nm, 1490/1625±10 nm

Spectral width < 5 nm (1310 nm), < 10 nm (1550 nm) < 5nm (1310 nm, 1490 nm), < 10nm (1550 nm) < 5nm (1310 nm, 1490 nm, 1625 nm) < 10nm (1550 nm)

Output power level -5 dBm ± 1 dB -5 dBm ± 1 dB -5 dBm ± 1dB

Power stability (15 min) < ± 0.05 dB < ± 0.05 dB (1310/1550 nm)< ± 0.1 dB (1490 nm) < ± 0.05 dB (1310/1550 nm)< ± 0.1 dB (1490/1625 nm)

Modulation CW, CHOP (270 Hz, 1 kHz, 2 kHz)

Power Source Three AA Cell batteries

Battery life time 25 hours

Laser Class CLASS1 (IEC 60825-1)

Dimensions (mm) Weight 76 (W) × 153 (H) × 43 (D) approx.300 g

AQ2170 Optical Power Meter AQ2180 Optical Power Meter AQ4280 Optical Light Source

AQ2170

AQ2170H

AQ2180

AQ2180H

AQ4280A

AQ4280B

AQ4280C

Features

Specifications by model

Standard Accessory

Due to the increase in broadband services such as FTTH (Fiber To The Home), the communication carriers are

reinforcing the infrastructure of optical fiber networks. In the introductory period of such networks, there is a strong

need for handy OPM/LS for installation and maintenance together with OTDRs. the AQ2170, AQ2170H, AQ2180

and AQ2180H Optical Power Meters, and the AQ4280A, AQ4280B and AQ4280C Optical Light Sources to address

installation and maintenance needs.

Connector adapter (FC, SC, LC, ferrule2.5, ferrule 1.25), Four AAA Cell batteries, Carrying pouch, Protector, Operation Guide, User's Manual (CD)

Connector adapter (FC, SC, LC, ferrule2.5, ferrule 1.25), Two AA Cell batteries, Carrying pouch, Protector, Operation Guide, User's Manual (CD)

Universal adapter (FC/PC, SC/PC, ST/PC Standard), Two AA Cell batteries, Carrying pouch, Protector, Operation Guide, User's Manual (CD)

AQ2170 Optical Power Meter AQ2180 Optical Power Meter AQ4280 Optical Light Source

57

Optic

al M

easu

ring

Inst

rum

ents

Optical Measuring Instruments

MFT-OLTS AQ1100

Model and Suffix Codes

General Specifications

The AQ1100 is an optical loss test set combining an optical power meter and

light sources in one unit. An optical power meter is a measuring instrument

usually used for optical loss tests. The AQ1100 supports up to MM850/1300

nm and SM1310/1550/1625 nm. Also, you can select a +27 dBm high power

optical meter. For the light source, three models are available depending on the

wavelength and fiber type used. For the optical power meter, you can select

from three models depending on the measurement power and the purpose of the

optical power meter.

Features

Display: 5.7-inch color LCD (640 × 480)

Loss test mode (only with /SPM or /HPM): Auto loss test, Loopback

test, Multi-core loss test

External interface: USB1.1 Type A and Type B (mini) × 1

Power supply: AC adapter voltage 100 to 120 VAC or 200 to 240 VAC (auto-

switching)

Battery (Li-ion) operation time 6 hours and charging time 5 hours

External dimensions: Approx. 217.5 mm (W) × 157 mm (H) × 74 mm (D)

Weight: Approx. 1 kg or less (including internal battery)

Model Suffix codes Description

AQ1100A LS: 1310/1550 nm

AQ1100B LS: 1310/1550/1625 nm

AQ1100D LS: MM850/1300, SM1310/1550 nm

Language

-HJ Japanese/English

-HE English

-HC Chinese/English

-HK Korean/English

-HR Russian/English

Power cord

-D UL/ CSA standard

-F VDE standard

-R AS standard

-Q BS, Singapore standard

-H GB standard, Complied with CCC

-P KC standard (S. Korea)

Optical power meter

-SPM Optical power meter

-HPM High power optical power meter

-PPM (AQ1100A only) PON Optical power meter

Optical connector

-USC SC type (LS port, and OPM port)

-UFC FC type (LS port, and OPM port)

-ULCLC type (LS port, and OPM port for -PPM),

ϕ 1.25 adapter(OPM port for -SPM and -HPM)

-ASC

(except AQ1100D)

SC/Angled-PC type (LS port, and OPM port for -PPM),

SC type (OPM port for -SPM and -HPM)

Factory installed options

/VLS Visible light source, optical connector: 2.5ϕ ferrule

/LAN Ethernet (10/100BASE-TX)

/SB Shoulder belt

AC adapter /AC1 Attach 739872 AC adapter*

* For the US and the countries that require CE marking. Standard Accessories

Power cord, AC adapter, battery pack, hand belt, user's manual (CD-ROM), operation guide

Optional Accessories

Models AQ1100A AQ1100B AQ1100D

Light source

performance

Wavelength (nm) *1 1310/1550 ± 25 1310/1550/1625 ± 251310/1550 ± 25 (SM) 850/1300 ±

30 (GI)

Light emitting device LD LD LD(SM), LED(GI)

SM (LD) spectral width (nm) *1 *2 <5 / <10 <5 / <10 / <10 <5 / <10

GI (LED) spectral width (nm) *1 *3 (FWHM) − − 40(typ)/140(typ)

Optical output level (dBm) -3 ± 1 -3 ± 1SM: -3 ± 1

GI: -20 ± 1

Level stability (dB) *4 ±0.05 ±0.05SM: ±0.05

GI: ±0.1

Modulation mode CW, CHOP(270 Hz, 1 kHz, 2 kHz) *5

Applicable fiber SM (ITU-T G.652) SM (ITU-T G.652)GI (50/125 μm)

Optical connector SC, FC, 1.25 mm ferrule, SC/Angled-PC SC, FC, 1.25 mm ferrule

Laser class 1

Specifications by Model

Model Suffix codes Description

SU2006A Soft carrying case

735480

(For opticalpower meters)

-SCC Connector adapter (SC)

-FCC Connector adapter (FC)

735481 -LMC Ferrule adapter (ϕ 1.25)

SU2005A

(For LS and PON optical power meter)

-SCC Universal adapter (SC)

-FCC Universal adapter (FC)

-LCC Universal adapter (LC)

739871 (AC adpter) -D UL/ CSA standard

-F VDE standard

-R AS standard

-Q BS, Singapore standard

-H GB standard, Complied with CCC

-P KC standard (S. Korea)

739872* (AC adpter) -D UL/CSA standard

-F VDE standard

-Q BS, Singapore standard

739882 Battery pack (Spare)

B8070CY Shoulder belt

* For the US and the countries that require CE marking

Optical Power Meter Performance and Functions

Standard (/SPM) High power (/HMP) PON (/PPM)

Wavelength setting

Simple mode: 850/1300/1310/1490/1550/1625/1650 nm

Detail mode setting range: 850 nm to 1650 nm, 1 nm step

CWDM mode setting range: 1270 nm to 1610 nm 20 nm step

1310/1490/1550 nm

(1490 nm and 1550 nm can be

measured separately)

Applicable fiber SM (ITU-G.652) GI (50/125 μm) SM (ITU-G.652)

Power range (dBm)-70 to +10 (CW)

-70 to +7 (CHOP)

-50 to +27 (CW)

-50 to +24 (CHOP) *6

-70 to +10: 1310/1490 nm

-50 to +27: 1550 nm

Noise level0.5 nW

(-63 dBm, 1310 nm)

50 nW

(-43 dBm, 1310 nm)

0.5 nW(-63 dBm, 1310 nm)

50 nW(-43 dBm, 1550 nm)

Uncertainty under standard

conditions *7±5% ±5% ±0.5 dB (10%)

Readout resolution 0.01

Level unit Absolute: dBm, mW, μW, nW, Relative: dB

Modulation modeCW

CHOP(270/1 k/2 kHz)

CW

CHOP(270/1 k/2 kHz)CW

Average function 1, 10, 50 and 100 times

Logging function Measurement intervals: 500 ms, 1 s, 2 s, 5 s, 10 s, Measurement count: 10 to 1000

Factory Installed Options

Visible light

source (/VLS)

Optical

connector2.5 mm ferrule type

Wavelength and

optical output

level

650 nm ±20 nm, peak

value -3 dBm or more

Modulation

frequencyApprox. 2 Hz

Laser class 3R

LAN interface (/

LAN)

10BASE-

T/100BASE-TX

RJ-45 connector

Ping test, PC remote

control

The specifications are at 23°C ±2°C unless otherwise noted.

*1: 23°C ±2°C, CW

*2: RMS (2 , -20 dB)

*3: Envelope (-3 dB)

*4: for 15 minutes at a constant temperature within 23°C ±2°C

*5: CW and 270 Hz only at 850 nm and 1300 nm

*6: Except for 850 nm and 1650 nm.

*7: 23°C ±2°C , standard conditions (CW, 1310 nm, 100 μW, SMF), at 1550

nm for /PPM.

*8: LD ON. (in screen save mode)

58

Optic

al M

easu

ring

Inst

rum

ents

Optical Measuring Instruments

MFT-1/10GbE AQ1300 Series

General Specifications

Display: 5.7-inch color LCD (640 × 480)

External interface: USB1.1 Type A and Type B (mini), LAN (RJ-45) × 1

Power supply: AC adapter 100 to 240 V, 50 to 60 Hz

Battery (Li-ion) operation time 1 hour

External dimensions: 217.5 (W) × 157 (H) × 74 (D) mm

Weight: Approx. 1.3 kg (including internal battery)

Model and Suffix Codes

Item Specifications

Interface

RJ-45 10BASE-T, 100BASE-TX, 1000BASE-T

SFP 1000BASE-SX, 1000BASE-LX

XFP*7 10GBASE-SR, 10GBASE-LR, 10GBASE-ER

Measurement function

Measurement menu Auto, Auto (Remote), Manual, OPM (Optical power meter)*8

Measurement mode TRAFFIC, QoS, PING, Loop Back, BERT

RFC2544 Throughput, Latency, Frame loss rate, Back-to-Back, Packet Jitter

Transmission functionFrame length 48 to 9999 bytes

QoS transmission Up to 8 channels (up to 4 ch in Auto and Auto (remote) mode)

Receive function

Receivable frame length 48 to 9999 bytes (Minimum IFG: 5 bytes)

Latency time measurement resolution

100 ns

Loop back function Field swap DA/SA of MAC address, DA/SA of IP address, Dst/Src port of TCP/UDP

Remote control function In-band remoteRemote test synchronization, Remote test start synchronization, Opposite tester automatic search(*), Opposite tester automatic addressing (*) ( *: Applicable only within a segment)

Layer-1 measurement functionReceiving clock measurement Measurement range: -100 to +100 ppm Measurement resolution: 0.1 ppm

LFS generation*9 Manual: Continuous transmission (Start/Stop), Auto: When a link down or LF is received, RF is transmitted automatically.

*7: Only available for the AQ1300 *8: Only available for the AQ1300 (option) *9: When the interface is XFP (10 G)

Specifications

Optional Accessories

Model Suffix codes Description

735454 Optical transceiver module

-SR*4 10GBASE-SR XFP module

-LR*4 10GBASE-LR XFP module

-ER*4 10GBASE-ER XFP module

-SX 1000BASE-SX SFP module

-LX 1000BASE-LX SFP module

739882 Battery pack (reserve)

SU2006A Soft carrying case

739871 AC Adapter*5

Power cord -D UL/CSA standard

-F VDE standard

-R AS standard

-Q BS standard

-H GB standard

-P KC standard

-T BSMI standard

739872 AC Adapter*6

-D UL/CSA standard

-F VDE standard

-Q BS, Singapore standard

B8070CY Shoulder belt

735480*4 -SCC SC connector adapter for optical power meters

-FCC FC connector adapter for optical power meters

735481 -LMC ϕ 1.25 connector adapter for optical power meters

-SFC ϕ 2.5 connector adapter for optical power meters

*4: Cannot be used with the AQ1301.

*5: For outside the US and the countries that require CE making.

*6: For the US and the countries that require CE making.

Model Suffix Code Description

AQ1301 AQ1301 MFT-1GbE

AQ1300 AQ1300 MFT-10GbE

Language -HE English

Power Coad -D UL/CSA standard

-F VDE standard

-R AS standard

-Q BS, Singapore Standard

-H GB standard, CCC correspondence

-P KC standard (South Korea)

-T BSMI, Taiwan Standard

Optical power meter*1 /SPML Standard Optical power meter

XFP module*1, *2 /SR 10GBASE-SR XFP module

/LR 10GBASE-LR XFP module

/ER 10GBASE-ER XFP module

SFP module*2 /SX 1000BASE-SX SFP module

/LX 1000BASE-LX SFP module

RFC2544*3 /BM RFC2544 Function

Shoulder belt /SB Shoulder belt

*1: Cannot be specified for the AQ1301

*2: For the SFP and XFP modules, be sure to use the modules listed above.

If you use other than an SFP or XFP module from Yokogawa, the functionality and performance of this product are

not guaranteed. Furthermore, the warranty will be void.

*3: Cannot be specified for the AQ1301 (this option is available for the AQ1301 as standard)

Features

The AQ1300 series is a compact and lightweight Ethernet tester that is

designed to improve both work efficiency and quality at the same time, with

function optimized for the network path testing and maintenance of Ethernet

networks up to 1G or 10G depending on model chosen.

Easy operation prevents operational errors and stabilizes work quality for

routine tasks such as network path testing.

Powerful analysis functions help isolate failures during maintenance work.

The AQ1300 series has two models, AQ1300 and AQ1301 to choose from

depending on the measurement interface and bit rate. You can choose the

model suitable for your test needs.

59

Optic

al M

easu

ring

Inst

rum

ents

Optical Measuring Instruments

High-performance OTDR Module

for Remote Fiber Test Systems

Model and Suffix Code

The AQ7277 is an OTDR module for RFTS (Remote Fiber Test System), which uses the advanced technology transferred from the AQ7275 high performance OTDR.

• Measurement at 1650 nm (Maintenance wavelength)

• Built-in 1310/1550 nm cut filter for live-fiber monitoring

• Allow to test PON system through high-port-count splitter

• Ethernet interface for fast data transfer

Features

External View

Remote OTDR AQ7277

Specifications

Model and suffix code: AQ7277-B01 OTDR optical connector (SC)

DC input +12 V(round jack)

USB connector(Type B)

DC input +12 V(square 4-pin connectorwith lock mechanism)

LED I/F connector(LED drive, PS-20PE)

LAN connector(RJ45)

Note: Dimensions exclude protrusions

Wavelength 1650 ±5 nm

Distance range (km) 0.5, 1, 2, 5, 10, 20, 50, 100, 200, 300, 400

Pulse width (ns) 3, 10, 20, 50, 100, 200, 500, 1,000, 2,000, 5,000, 10,000, 20,000

Sampling resolution 5 cm, 10 cm, 20 cm, 50 cm, 1 m, 2 m, 4 m, 8 m, 16 m, 32 m

Dynamic range 37 dB (typ.)

Event dead zone 0.8 m (typ.)

Attenuation dead zone 12 m (typ.)

Distance measurement accuracy ±1 m ±measurement distance x 2 x 10-5 ±1 sampling resolution

Number of sampling data Max.100,000 points

Control interface LAN (10BASE-T, 100BASE-TX), USB1.1 (Type B)

Alarm output LED drive signal

Environmental conditions Operating temperature 0 to +50°C

Storage temperature -20 to +60°C

Humidity 20 to 85% (no condensation)

DC power supply 12 V DC to 19.5 V DC 1.5 A or less (at 12 V DC), 1 A or less (at 19.5 V DC)

Dimensions and weight 277 mm (W) × 190 mm (D) × 73 mm (H) (excluding protrusions), approx. 2 kg

Laser safety standards Class 1M

60

Cal

ibra

tor

Calibrator

CA700 Pressure Calibrator

Hand Pump Series

High Accurate and High Functional Pressure Calibrator Specially Designed for the Calibration of

Differential Pressure and Pressure Transmitters.

Three High-Performance Hand Pump Models Available

• Smooth pressurization with less internal leaking• Strainer preventing debris from entering the pump included• Low Pressure Hand Pump Pressure generation range: -83 to 700 kPa Ultra-compact hand pump• Pneumatic Hand Pump Pressure generation range: -83 to 4,000 kPa High-performance small hand pump with a wide range of pressure generation•Hydraulic Hand Pump Pressure generation range: 0 to 70 MPa High-performance hand pump capable of generating a pressure of up to 70

MPa

Pressure MeasurementModel CA700-E-01 CA700-E-02 CA700-E-03

Pressure type Gauge

Measurement

range

Positive pressure 0 to 200 kPa

Negative pressure -80 to 0 kPa

Positive pressure 0 to 1,000 kPa

Negative pressure -80 to 0 kPa

Positive pressure 0 to 3,500 kPa

Negative pressure -80 to 0 kPa

Measurement

display rangeUp to 240.000 kPa Up to 1,200.00 kPa Up to 4,200.00 kPa

Measurement

accuracy

(6 months after

calibration)

(Tested after

zero calibration)

Positive pressure

20 to 200 kPa:

±(0.01% of reading + 0.003 kPa)

0 to 20 kPa: ±0.005 kPa

Positive pressure

±(0.01% of reading + 0.04 kPa)

Positive pressure

±(0.01% of reading + 0.15 kPa)

Negative pressure

±(0.2% of reading + 0.090 kPa)

Negative pressure

±(0.2% of reading + 0.08 kPa)

Negative pressure

±(0.2% of reading + 0.08 kPa)

Measurement

fluidGas and liquid (non-corrosive, non-flammable, non-explosive, and non-toxic fluids)

Pressure

display units

kPa and other units

(Pa, hPa, MPa, mbar, bar, atm, mmHg, inHg, gf/cm2, kgf/cm2, mmH2O@4˚C, mmH2O@20˚C,

ftH2O@4˚C, ftH2O@20˚C, inH2O@4˚C, inH2O@20˚C, Torr, psi)

Input port Rc 1/4 or 1/4 NPT female thread (selectable)

Current and Voltage Measurement (common to all models)

DC current0 to ±20.000 mA ±(0.015% of reading + 3 μA)

0 to ±100.00 mA ±(0.015% of reading + 30 μA)

DC voltage0 to ±5.0000 V ±(0.015% of reading + 0.5 mV)

0 to ±50.000 V ±(0.015% of reading + 5 mV)

24 V Loop power supply

Supply

voltage

24 V ± 1 V Load current 24 mA when communication resistance OFF

24 V ± 6 V Load current 20 mA when communication resistance ON

Current and voltage source (common to all models)DC current* 0 to 20.000 mA ±(0.015% of setting + 3 μA)

DC voltage 0 to 5.0000 V ±(0.015% of setting + 0.5 mV)

* External power supply for 20 mA SIMULATE: 5 to 28 V

Main Specifications

Example of field calibration of differential pressureand pressure transmitter

Calibration of pressure transmitters is required to accurately measure the

input and output values and to calculate the error rate.

The CA700 ensures reliable calibration with its function to accurately

measure the input and output values of pressure and current. Additionally

its embedded calibration procedures enable users to perform certain

calibration following the prescribed procedure.

Hand pump Differential pressure and pressure transmitter

Product name Model Description of kit (individual models)

Hand Pump Kit (Low pressure) 91050 Hand Pump (91051), Connector Set (91052), Case (93052)

Hand Pump Kit (Pneumatic) 91055 Hand Pump (91056), Connector Set (91057), Case (93053)

Hand Pump Kit (Hydraulic) 91060 Hand Pump (91061), Connector Set (91062), Case (93053)

CA700

Detailed catalog: Bulletin CA700-EN

Model 91050 Model 91055 Model 91060

Detailed catalog: Bulletin CA700-EN

Features

Features

• Basic accuracy: Pressure (measurement) 0.01% rdg Current (source/measurement) 0.015% rdg Voltage (source/measurement) 0.015% rdg• Widest range and highest resolution in class achieved 200 kPa gauge pressure model (resolution 0.001 kPa) 1000 kPa gauge pressure model (resolution 0.01 kPa) 3500 kPa gauge model (resolution 0.01 kPa)• DC mA signals can be measured by supplying power to the transmitter from

a 24V DC power supply.• Calibration procedures of pressure transmitters and pressure switches are

embedded. “As Found”, “ As Left” data and error rate (%) can be recorded.• IP54 dustproof and waterproof robust case enables use in harsh environments.• Hart and Brain communication resistance is embedded.• Dimensions: Approx. 264 (W) × 188 (H) × 96 (D) mm Weight: Approx. 2 kg (including 6 AA size batteries)

61

Cal

ibra

tor

Calibrator

Features

• Highly accurate within 0.02% of the DC voltage range for source and measure• Source and measurement can be performed simultaneously• Vertical body with large-screen display• Loop power supply function (24 V DC at a load of max 22 mA) It is possible to measure current in the mA range while supplying power• Sink function• Sweep functions that allow 3 types of continuous outputs: Step sweep function Linear sweep function Program sweep function

Optional Accessories (sold separately)

High accuracy and compact design

CA150Handy Calibrator

Specifications

General Specifications

Common source specifications• Power supply: 6 AA size alkaline batteries AC adapter (sold separately) or dedicated NiMH battery (sold separately)• Battery life Conditions: Simultaneous Source/measurement When 6 batteries are used: Approx. 8 hours When NiMH battery is used: Approx. 10 hours• Auto power-off: Approx. 10 minutes• Insulation resistance: Between input terminal and output terminal: 500 V DC, 50 MΩ or more• Withstand voltage: Between measurement terminal and generation terminal: 350 V AC, 1 minute• Operating temperature/humidity range: 0 to 40°C, 20 to 80%RH (no condensation)• Storage temperature range: -20 to 60°C 90%RH or less (no condensation)• External dimensions: Approx. 251 × 124 × 70 mm• Weight: Approx. 1000 g (with Batteries)• Conforming Standards: Safety EN61010-1, UL61010-1, CAN/ CSA C22.2 No. 61010-1 EMC EN 61326 Class B; EN 55011 Class B Group1 EN 61000-3-2; EN 61000-3-3

Product name

94010

AC adapter

B9108WA

For reference junction compensation

RJ sensor

B9108XA

Lead cables, RJ sensor, etc. can be stored.

Accessory storage case

94015

NiMH battery Dedicated

NiMH battery

93027

With strap and accessory storage case

Main body case

98064

Alligator clip, CAT I, for controlsignal only (under 70 V)

One set of 1 red and 1 black cablesLength: Approx. 1.7 m

Lead cable for measurement

Model name

Remark

-D-F-H-N-P-R-S

For UL/CSA StandardFor VDE StandardFor GB StandardFor NBR StandardFor KC StandardFor AS StandardFor BS Standard

Range Resolution Source range Accuracy

100 mV 1 μV 0 to ±110.000 mV ±(0.02% + 10 μV)

1 V 10 μV 0 to ±1.10000 V ±(0.02% + 0.05 mV)

10 V 0.1 mV 0 to ±11.0000 V ±(0.02% + 0.5 mV)

30 V 10 mV 0 to ±30.00 V ±(0.02% + 10 mV)

DC current 20 mA 1 μA 0 to +22.000 mA ±(0.025% + 3 μA)

mA SINK 20 mA SINK 1 μA 0 to -22.000 mA ±(0.025% + 6 μA)

500 Ω 0.01 Ω 0 to 550.00 Ω ±(0.02% + 0.1 Ω)

5 kΩ 0.1 Ω 0 to 5.5000 kΩ ±(0.05% + 1.5 Ω)

50 kΩ 1 Ω 0 to 55.000 kΩ ±(0.1% + 50 Ω)

PT100 -200.0 to 850.0°C ±(0.025% + 0.3°C)

JPT100 -200.0 to 500.0°C

K -200.0 to -100.0°C ±(0.02% + 0.8°C)

-100.0 to 1372.0°C ±(0.02% + 0.5°C)

E -200.0 to -100.0°C ±(0.02% + 0.6°C)

-100.0 to 1000.0°C ±(0.02% + 0.4°C)

J -200.0 to -100.0°C ±(0.02% + 0.7°C)

-100.0 to 1200.0°C ±(0.02% + 0.4°C)

T -200.0 to -100.0°C ±(0.02% + 0.8°C)

-100.0 to 400.0°C ±(0.02% + 0.5°C)

N -200.0 to 0°C ±(0.02% + 1.0°C)

0.0 to 1300.0°C ±(0.02% + 0.5°C)

L -200.0 to 900.0°C ±(0.02% + 0.5°C)

U -200.0 to 0°C ±(0.02% + 0.7°C)

0 to 400.0°C ±(0.02% + 0.5°C)

R 0 to 100°C ±(0.02% + 2°C)

100 to 1768°C ±(0.02% + 1.2°C)

S 0 to 100°C ±(0.02% + 2°C)

100 to 1768°C ±(0.02% + 1.2°C)

B 600 to 1000°C ±(0.02% + 1.5°C)

1000 to 1820°C ±(0.02% + 1°C)

100 Hz 0.01 Hz 1.00 to 110.00 Hz ±0.05 Hz

1000 Hz 0.1 Hz 90.0 to 1100.0 Hz ±0.5 Hz

10 kHz 0.1 kHz 0.9 kHz to 11.0 kHz ±0.1 kHz

50 kHz 1 kHz 9 kHz to 50 kHz ±1 kHz

CPM 0.1 CPM 1.0 to 1100.0 CPM ±0.5 CPM

Range Resolution Measurement range Accuracy

500 mV 10 μV 0 to ±500.00 mV ±(0.02% + 50 μV)

5 V 0.1 mV 0 to ±5.0000 V ±(0.02% + 0.5 mV)

35 V 1 mV 0 to ±35.000 V ±(0.025% + 5 mV)

20 mA 1 μA 0 to ±20.000 mA ±(0.025% + 4 μA)

100 mA 10 μA 0 to ±100.00 mA ±(0.04% + 30 μA)

500 Ω 0.01 Ω 0 to 500.00 Ω ±(0.055% + 0.075 Ω)

5 kΩ 0.1 Ω 0 to 5.0000 kΩ ±(0.055% + 0.75 Ω)

50 kΩ 1 Ω 0 to 50.000 kΩ ±(0.055% + 10 Ω)

PT100 -200.0 to 850.0°C

JPT100 -200.0 to 500.0°C

K -200.0 to 1372.0°C

E -200.0 to 1000.0°C

J -200.0 to 1200.0°C

T -200.0 to 400.0°C

N -200.0 to 1300.0°C

L -200.0 to 900.0°C

U -200.0 to 400.0°C

R 0 to 1768°C

S 0 to 1768°C

B 600 to 1800°C

100 Hz 0.01 Hz 1.00 to 110.00 Hz

1000 Hz 0.1 Hz 1.0 to 1100.0 Hz ±2 dgt

10 kHz 0.001 kHz 0.001 to 11.000 kHz

CPM 1 CPM 0 to 100000 CPM ----

CPH 1 CPH 0 to 100000 CPH ----

Loop power supply 24 V LOOP 24 V±2 V

Source Unit

Measurement Unit

DC voltage

Resistance

RTD

Thermocouple

DC voltage

DC current

Resistance

Thermocouple

RTD *5

Pulse

Frequency/pulse

0.1°C

0.1°C

0.1°C

±(0.05% + 1.5°C)/-100°Cor more±(0.05% + 2°C)/-100°Cor less

±(0.05% + 0.6°C)

±(0.05% + 2°C)/100°Cor more±(0.05% + 3°C)/100°Cor less

1°C

0.1°C

1°C

Temperature coefficient: Accuracy above x (1/10)/°CThe temperature coefficient is added in the ranges from 0 to 18°C and from 28 to 40°C

Temperature coefficient: Accuracy above x (1/10)/°CThe temperature coefficient is added in the ranges from 0 to 18°C and from 28 to 40°C

Accuracy=±(% of setting + μV, mV, μA, Ω and °C) at 23°C±5°C

Accuracy=±(% of reading + μV, mV, μA, Ω or dgt(digit)) at 23°C±5°C

62

Cal

ibra

tor

Calibrator

Features

• Source and measure operations can be performed at the same time. (Select from the following source signal and measurement signal options:

voltage, current, resistance, thermocouple (TC), resistance temperature detector (RTD), frequency, pulse).

• AC voltages, including supply voltage, can be measured. • Easy operation.• Compact size and Lightweight• Includes a wide array of additional functions. • Source Values set in steps of 4-20 mA 24V DC Power Supply to Transmitter • Divided output (n/m) function Output settings are divided, eliminating the need for bothersome

calculations for percentage output. • Autostep function Changes the output value in step form based on the setting from the

divided output (n/m) function. Changes can be sourced automatically every 10% or 25%.

• Online communication (CA71 only) RS-232C-compliant optically isolated interface • Sweep function Linearly increases or decrease the output. The increasing/decreasing time

can be set to either 16 or 32 seconds. • Memory function Source values and measurements forming individual value sets can be

saved to or read from the Handy Calibrator's internal memory (maximum 50 value sets).

• Temperature monitor function

Simultaneous Signal Source and Measurement Capability

Specifications

General Specifications

CA51/CA71Handy Calibrators

Parameter

Power supply

Battery life

Auto-power-off function

Applicable standards

Operating temperature

and humidity ranges

External dimensions

(WHD)

Weight

Specifications

Four AA alkaline batteries, or special AC adapter (sold separately)

Measurement off, output 5 V DC/10 kΩ or greater: Approximately

40 hours

Simultaneous signal generation/measurement, output 5 V DC/10

kΩ or greater: Approximately 20 hours

Simultaneous signal generation/measurement, output 20 mA/5 V:

Approximately 12 hours

(using alkaline batteries, with backlight off)

Approximately 10 minutes (auto-power-off can be disabled through

a DIP switch setting)

IEC61010-1, IEC61010-2-31

EN61326-1

EN55011, Class B, Group 1

0–50°C, 20–80% RH (no condensation)

Approximately 190 × 120 × 55 mm

Approximately 730 g (including batteries)

Parameter

DC voltage

DC current

mA SINK

Resistance

RTD

TC

Frequency,

pulse

Reference

100 mV

1 V

10 V

30 V

20 mA

4–20 mA

20 mA

400 Ω

Pt100

JPt100

K

E

J

T

N

L

U

R

S

B

500 Hz

1000 Hz

10 kHz

Pulse cycle

Range

-10.00–110.00 mV

0–1.1000 V

0–11.000 V

0–30.00 V

0–24.000 mA

4/8/12/16/20 mA

0.1–24.000 mA

0–400.00 Ω

-200.0–850.0°C

-200.0–500.0°C

-200.0–1372.0°C

-200.0–1000.0°C

-200.0–1200.0°C

-200.0–400.0°C

-200.0–1300.0°C

-200.0–900.0°C

-200.0–400.0°C

0–1768°C

600–1800°C

1.0–500.0 Hz

90–1100 Hz

0.9 kHz–11.0 kHz

1–99,999 cycles

Resolution

10 μV

0.1 mV

1 mV

10 mV

1 μA

4 mA

1 μA

0.01 Ω

0.1°C

0.1°C

1°C

0.1 Hz

1 Hz

0.1 kHz

1 cycle

Accuracy (23±5°C per year)

±(0.02% + 15 μV)

±(0.02% + 0.1 mV)

±(0.02% + 1 mV)

±(0.02% + 10 mV)

±(0.025% + 3 μA)

±(0.05% + 3 μA)

±(0.025% + 0.1 Ω)

±(0.025% + 0.3°C)

±(0.02% + 0.5°C)

(-100°C or greater)

±(0.02% + 1°C)

(-100°C or less)

±(0.02% + 0.5°C)

(0°C or greater)

±(0.02% + 1°C)

(0°C or less)

±(0.02% + 2.5°C)

(100°C or less)

±(0.02% + 1.5°C)

(100°C or greater)

±(0.02% + 2°C)

(1000°C or less)

±(0.02% + 1.5°C)

(1000°C or greater)

±0.2 Hz

±1 Hz

±0.1 kHz

Source Unit

Measurement Unit

Parameter

DC voltage

DC current

Resistance

AC voltage

Frequency, pulse

Reference

100 mV

1 V

10 V

100 V

20 mA

100 mA

400 Ω

1 V

10 V

100 V

300 V

100 Hz

1000 Hz

10 kHz

CPM

CPH

Accuracy (23±5°C per year)

±(0.025% + 20 μV)

±(0.025% + 0.2 mV)

±(0.025% + 2 mV)

±(0.05% + 20 mV)

±(0.025% + 4 μA)

±(0.04% + 30 μA)

±(0.05% + 0.1 Ω)

±(0.5% + 5 dgt)

±(0.5% + 2 dgt)

±2 dgt

Resolution

10 μV

0.1 mV

1 mV

0.01 V

1 μA

10 μA

0.01 Ω

1 mV

0.01 V

0.1 V

1 V

0.01 Hz

0.1 Hz

0.001 kHz

1 CPM

1 CPH

• Both CA51 and CA71

Parameter

TC

RTD

Reference

K

E

J

T

N

L

U

R

S

B

Pt100

JPt100

Resolution

0.1°C

1°C

0.1°C

Accuracy (23±5°C per year)

±(0.05% + 1.5°C)(-100°C or greater)

±(0.05% + 2°C)(-100°C or less)

±(0.05% + 2°C)(100°C or greater)

±(0.05% + 3°C)(100°C or less)

±(0.05% + 0.6°C)

• CA71 only

63

Cal

ibra

tor

Calibrator

Process Calibrator CA310, CA320, CA330

High-performance Model Specialized for Loop InspectionCA310Volt mA calibrator

• Basic accuracy: 0.015% (source and measurement accuracy of voltage mA)

• 20 mA SIMULATE (SINK) function• Simultaneously measures 24-V loop power and output signals

with high accuracy• Built-in HART/BRAIN communication resistance (250 Ω)• Sub-display indicates span% of the source value.• Handles various source patterns

(Step sweep/linear sweep/manual step/span check)

Specifications

Source V DC : 500 mV/5 V/30 V mA DC : 20 mA/20 mA SIMULATEMeasurement V DC : 500 mV/5 V/30 V/50 V mA DC : 20 mA/50 mA 24-V loop power source:

24 V±1 V (communication resistance: off) 24 V±6 V (communication resistance: on)

General specifications • Dimensions : 90 (W) × 192 (H) × 42 (D) mm • Weight : Approx. 440 g • Power source : AA battery (LR6) × 4 or dedicated AC/DC

adaptor (option) • Sweep function : Step (25%)/linear • Sweep time : 15 sec/30 sec/45 sec/60 sec

Bulletin: CA300-EN

High-performance Model Specialized for Simulating ThermocouplesCA320TC calibrator

• Basic accuracy: 0.5ºC (typical of Type K) * Including the accuracy of an internal RJC• Accepts 16 types of thermocouple (JIS/IEC/DIN/ASTM/GOST R)• Sub-display indicates the voltage source value and span%.• Simulates other types of thermocouple with the mV source

function• Works as a thermometer to measure the output from the TC

sensor• Handles various source patterns (Step sweep/linear sweep/manual step/span check)

Specifications

Source Thermocouple : K, E, J, T, N, L, U, R, S, B, C, XK, A, D, G, PLATINEL2

mV DC : 90 mVMeasurement Thermocouple : K, E, J, T, N, L, U, R, S, B, C, XK, A,

D, G, PLATINEL2 mV DC : 90 mVGeneral specifications • Dimensions : 90 (W) × 192 (H) × 42 (D) mm • Weight : Approx. 440 g • Power source : AA battery (LR6) × 4 or dedicated AC/DC

adaptor (option)

Bulletin: CA300-EN

High-performance Model Specialized for Simulating RTDsCA330RTD calibrator

• Basic accuracy: 0.3ºC (typical of PT100)• Accepts 14 types of RTD (JIS/IEC/GOST R)• Sub-display indicates the resistance source value and span%.• Accepts 2-, 3-, 4-wire systems and simulates RTDs precisely• Simulates other types of RTD with the resistance source function• Works as a thermometer to measure the output from the RTD

sensor• Handles various source patterns

(Step sweep/linear sweep/manual step/span check)

Specifications

Source RTD : PT100 (four types), PT200, PT500, PT1000, Cu10, Ni120, Extra RTD (five types)

Resistance : 500 Ω/3000 ΩMeasurement RTD : PT100 (four types), PT200, PT500,

PT1000, Cu10, Ni120, Extra RTD (five types)

Resistance : 500 Ω/3000 ΩGeneral specifications • Dimensions : 90 (W) × 192 (H) × 42 (D) mm • Weight : Approx. 440 g • Power source : AA battery (LR6) × 4 or dedicated AC/DC

adaptor (option)Bulletin: CA300-EN

Spare parts

Optional accessories (sold separately)

Product

Model 98020

Source signal lead cable

RD031

Measurement lead cable Carrying case

99021

Terminal adapter

93016

Product

Model

Remarks

94013120 V AC

94016-F220 to 240 V AC

VDE standard

94016-S220 to 240 V AC

BS standard

AC adapter

B9108WAFor reference junction

compensation

RJ sensor

B9108XALead cables, RJ sensor, etc.

can be stored

Accessory storage case

91017D-sub 9-pin (female)

Communication cable (RS232)

64

Cal

ibra

tor

Calibrator

64

Features

• Loop check functions • Simultaneous 24 V loop power and mA measurement • HART/BRAIN mode setting with loop power (Adds 250 ohm resistance internally)• Generation functions • SIMULATE (SINK) function simulates transmitters • 4-20 mA span/step/auto-step/sweep output• Measurement functions • High accuracy signal measurement:DC mA 0.05%/30.000 mA • Handheld DMM function • Peak Hold function for the peak voltage measurement of DCS power

supply • Dedicated sensor modes for direct reading of many sensor signal types• Enhanced Safety—helps eliminate electric shocks • Current terminal shutter prevents incorrect connections • 1 A or more of AC/DC current can be read directly using the optional

clamp probe and scaling in SENSOR mode.*1 • Measurement categories 600 V CAT. IV, 1000 V CAT. III *1: AC/DC 600 mV range only

Loop Power and 4 to 20 mA Output function in a DMM

CA450Process Multi Meter

Specifications

General Specifications

Specificaton• Display : 5-digit (7 Segment) Measurement DC current 33000, Frequency 19999, Other 6600 Output DC current 25000• Operating temperature and humidity: -20 to 55°C (80%RH or less) with no

condensation• Storage temperature and humidity: -40 to 70 (70%RH or less) with no

condensation • Battery life: DC voltage measurment: Appox.140 hours DC current output (SIMULATE) Approx.140 hours DC current output (SOURCE) 12 mA (500 Ω load) Approx.10 hours• External dimensions: Approx. 90 (W) × 192 (H) × 49 (D) mm• Weight: Approx. 600 g (including the batteries)• Compliant standards:• Safety standards: EN61010-1 and EN61010-031

Measurement Categories:1000 V CATIII, 600 V CATIVFor current measurement and output: 48 V max, 100 mA maxLead cables (98064): 70 VDC, 100 mAPollution degree 2, indoor useVibration: Sweep vibration frequencies 10 Hz to 5 Hz to 10 Hz Amplitude 0.15 mm (peak value)Duration 30 minutesShock: 1 m drop test as defined by the safety standardsAltitude: 2000 m or lessEMC standards: EN61326-1 Class B, EN61326-2-2 EN55011 Class B Group 1Influence of radiated immunity: In RF electromagnetic fields of 3 V/mEN61326-1 AC voltage measurement, 600 mV range:1.5% of rangeDC voltage measurement, 600 mV range:1% of rangeDC current measurement, all ranges: 1.5% of rangeDC current output: 1.5% of rangeEN61326-2-2 AC voltage measurement (6 V range or higher): Within 5 times the accuracyDC voltage measurement (6 V range or higher): Within 5 times the accuracy

Measurement

Function Range Resolution Max Accuracy

DCV600 mV/6 V/60 V/600 V/1000 V

0.1 mV/0.001 V/0.01 V/0.1 V/1 V 0.09%+2 digits

ACV 0.1 mV/0.001 V/0.01 V/0.1 V/1 V 0.5%+5 digits

DCA 30 mA/60 mA 0.001 mA/0.01 mA 0.05%+2 digits

Resistance600 Ω/6 kΩ/60 kΩ/600 kΩ/6 MΩ /60 MΩ

0.1 Ω/0.001 kΩ/0.01 kΩ/0.1 kΩ0.001 MΩ/0.01 MΩ

0.2%+2 digits

10Hz to 199.99 Hz 0.01 Hz

0.005%+1 digitsFreq 90Hz to 1999.9 Hz 0.1 Hz

0.900 kHz to 19.999 kHz 0.001 kHz

Source

DCmA 20 mA 0.001 mA 0.05% of range

Loop Power 24 V24 VDC (typ.)

Load current 20 mA

Other Functions and Spection

Functions Diode check, Continutity check, Data Hold, Peak Hold, Step mode, linear mode, Sesor mode, MIN/MAX, RELΔ%

Accessories

Test leads

Model:98073

Lead Cables

Model:98064

Fuse

Model:99042DMM Communication Package

92015 (*1)

Alligator

Test leads

Model:99014

AC/DC

Clamp-on Probe

Model:96095

Current

Clamp-on Probe

Model:96001

Carrying Case

Model:93029

Magnet hook

Model:99032

The Magnet hook

can be attached

to magnetic body

(e.g. iron).

The inner case

with detachable

straps can be

hung on bar.

Carrying Case

Model:93043-P1

(*1) Settings for output is not capable.

65

Cal

ibra

tor

Calibrator

High-end Model for Measuring Power Consumption and Power Quality

Clamp Power Meter CW500

CW500Power quality analyzer

• Achieves various power measurements with simple operations - One press on direct keys switches to any of five measurement displays.• Identifies power source malfunctions - Sampling with a 24-μs resolution can identify temporary malfunctions. - Measures harmonics and flickers• User support - Easy wiring and setting with the start navigation function and automatic detection of

clamp-on probes• PC software for analysis and setting comes as standard. - Data can be compiled into graphs and reports with one click.

Specifications

Wiring connection: 1P2W (max. 4 systems), 1P3W (max. 2 systems), 3P3W 2 currents (max. 2 systems), 3P3W 3 currents, 3P4WInput: 3 channels for voltage, 4 channels for current,

2 channels for DC voltageRange: AC voltage 600.0/1000 V AC current 2000 mA to 3000 A (depending on a clamp-on probe) AC power 3000 W to 3000 kW (depending on a clamp-on probe) DC voltage 100.0 mV/1.000 V/10.00 VAccuracy: Voltage ±0.2%rdg ± 0.2%rng Current ±0.2%rdg ± 0.2%rng + accuracy of clamp-on probes Power ±0.3%rdg ± 0.2%rng + accuracy of clamp-on probes Effect of power factor ±1.0%rdg (reading at power factor 0.5 against 1.0)Measurement items: • Voltage, current, frequency, power factor, effective/reactive/

apparent power • Consumption/generation of effective/apparent power,

delay/progress of reactive power • Demand, maximum demand, load factor, estimated demand value • Temporary malfunction: voltage swell, voltage dip, voltage

interrupt, transient overvoltage, inrush current • Continuous malfunction: components of up to the 50th harmonic

(RMS, content rate, and phase angle of voltage, current, and power), total harmonic distortion rate, IEC flicker, voltage unbalance rate, current unbalance rate

Measurement display: measurement values, trend graphs for all or each channel from the start of measurement, measured demand values, demand trend over a specific period or a whole period

Record interval: 1/2/5/10/15/20/30 sec, 1/2/5/15/20/30 min, 1 h/2 hGeneral specification: Dimensions: 120 (W) × 175 (H) × 68 (D) mm Weight: Approx. 900 g (including batteries) Power source: 100 to 240 V AC /50 to 60 Hz/alkaline AA battery ×

6/power supply adaptor (option)Accessories: Voltage probe, USB cable, power cord, carrying bag, SD card,

startup guide, alkaline AA battery × 6, input terminal plate × 6, PC software

Clamp power meter 96060 series

Bulletin: CW500-EN

Clamp-on probes for the CW500 power meterModel code 96060 96061 96062 96063 96064 96065 96066

Clamp-on probe

Measurable diameter

ϕ40 mm ϕ18 mm ϕ24 mm ϕ30 mm ϕ40 mm ϕ110 mm ϕ150 mm

Measuring range 2 A AC 50 A AC 100 A AC 200 A AC 500 A AC 1000 A AC300 A AC1000 A AC3000 A AC

Output voltage 50 mV AC (25 mV/A) 500 mV AC (10 mV/A) 500 mV AC 500 mV AC 500 mV AC 500 mV AC500 mV ACFor each range

Accura

cy Leve

l

50 Hz/60 Hz

±1.0% rdg ±0.05 mV

±0.5% rdg ±0.1 mV

±0.5% rdg ±0.1 mV

±0.5% rdg ±0.1 mV

±0.5% rdg ±0.1 mV

±0.8% rdg ±0.2 mV

±1.0% rdg*

40 Hz to 1 kHz

±2.0% rdg ±0.1 mV

±0.8% rdg ±0.2 mV

±1.0% rdg ±0.2 mV

±0.8% rdg ±0.2 mV

±1.0% rdg ±0.2 mV

±1.5% rdg ±0.4 mV

1 kHz to 3.5 kHz

±3.0% rdg ±0.2 mV

±1.0% rdg ±0.4 mV

—±1.0% rdg ±0.4 mV

— — —

Accuracy Degree

—Less than ±2.0° (0.5 to 50 A, 40 Hz to 3.5 kHz)

Less than ±2.0° (1 to 100 A, 45 Hz to 65 Hz)

Less than ±1.0° (2 to 200 A, 40Hz to 3.5kHz)

Less than ±1.0° (5 to 500 A, 45 Hz to 65 Hz)

Less than ±2.0° (45 Hz to 65 Hz)Less than ±3.0° (40 Hz to 1 kHz)

Less than ±1.0° (for each range/45 to 65 Hz)

Max Circuit voltage

AC 300 Vrms AC 300 Vrms AC 300 Vrms AC 600 Vrms AC 600 Vrms AC 600 Vrms AC 600 Vrms

Dimensions 70 × 120 × 25 mm 52 × 106 × 25 mm 60 × 100 × 26 mm 73 × 130 × 30 mm 81 × 128 × 36 mm 73 × 130 × 30 mm 61 × 111 × 43 mm

Weight Approx. 250 g Approx. 170 g Approx. 160 g Approx. 250 g Approx. 260 g Approx. 170 g Approx. 950 g

Remarks These probes are dedicated for the CW500 and cannot be used for the CW240/CW120/CW121.

*45 to 65 Hz (measuring at the center of sensor)

66

Cla

mp-

onP

ower

Met

er

Clamp-on Power Meter

CW10Clamp-on Power Meter

A Powerful Power Measuring Tool

Features

• AC / DC Power up to 600 kW• True RMS for AC.• Harmonics 1st to 25th order• Power fluctuation using the ACA Inrush and Peak hold functions.• AC / DC Voltage max. 1000 V• AC / DC Current max. 600 A• Frequency, Resistance, Continuity, Diode check, Power factor.• Up to 9999 counts, approx. 37 mm max. diameter of measurable conductor (the jaw opens

approx. 45 mm max.)

Specifications

Accuracy23± 5ºC, 80%RH or lessAccuracy: ±(% of reading + digits)

Voltage Rms-value detection

Function RangeResolution

(Maximum reading)Accuracy*

DCV100 V 99.99 V

0.7% + 21000 V 999.9 V

ACV100 V 99.99 V 1.0% + 5

50 to 500 Hz1000 V 999.9 V

LPFACV

100 V 99.99 V 50 ≤ f ≤ 60 Hz: 1.0% + 560 < f ≤ 400 Hz: 5.0% + 51000 V 999.9 V

* DCV<1000 digits: add 6 digits to accuracy ACV<1000 digits: add 3 digits to accuracyMaximum input voltage: 1000 Vrms, 1414.2 VpkInput impedance: approx. 3.5 MΩ, <100 pFAC+DC Vrms accuracy=ACV accuracy + DCV accuracy

Crest factor effects1.4 < CF ≤ 2.0: add 1.0% of reading to accuracy2.0 < CF ≤ 2.5: add 2.5% of reading to accuracy2.5 < CF ≤ 3.0: add 4.0% of reading to accuracy

Maximum input voltage: 690 Vrms CF=2 460 Vrms CF=3

Current Rms-value detection

Function RangeResolution

(Maximum reading)Accuracy*

DCA100 A 99.99 A 1.5% + 20

600 A 600.0 A*** 1.5% + 5*

ACA100 A** 99.99 A 50 ≤ f ≤ 60 Hz : 1.5% + 5*

60 < f ≤ 400 Hz : 2.0% + 5*600 A 600.0 A***

LPFACA

100 A** 99.99 A 50 ≤ f ≤ 60 Hz : 1.5% + 560 < f ≤ 400 Hz: 5.0% + 5600 A 600.0 A***

*The measured value <1000 digits: add 5 digits to accuracy**Input current ≥ 0.10 A at 100 A range of ACA and LPF ACA***600 A : Guaranteed accuracy (not maximum reading)Maximum input current: 600 Arms, 848.5 ApkConductor position effects: ±1.0% of readingAC+DC Arms accuracy=ACA accuracy + DCA accuracy

Crest factor effects1.4 < CF ≤ 2.0: add 1.0% of reading to accuracy2.0 < CF ≤ 2.5: add 2.5% of reading to accuracy2.5 < CF ≤ 3.0: add 4.0% of reading to accuracy

Maximum input current: 420 Arms CF=2 280 Arms CF=3

Peak Hold (AC mode only)

Function RangeResolution

(Maximum reading)Accuracy

ACV100 V 140.0 V

3.0% + 151000 V 1400 V

ACA100 A 140.0 A

3.0% + 15600 A 850 A

PEAK MAX: polarity+, polarity-Maximum input voltage and current: 1000 Vrms, 600 ArmsSine wave, ACV ≥ 5 Vrms, ACA ≥ 5 Arms, 50 to 400 Hz continuous wave

Frequency (Hz)

Function Resolution (Measuring range) Accuracy

100 Hz 20.00 to 99.99 Hz

0.5% + 31000 Hz 20.0 to 999.9 Hz

10 kHz 0.020 to 9.999 kHz

Maximum input voltage and current: 1000 Vrms, 600 Arms

Input condition; 100 V range: 10 to 100 Vrms

(Sine wave) 1000 V range: 100 to 1000 Vrms

100 A range: 10 to 100 Arms (<400 Hz)

600 A range: 100 to 600 Arms (<400 Hz)

The measured value < approx. 10 Hz: 0.00 Hz

Harmonic MeasurementIndividual Harmonic

Harmonic order Resolution (Maximum reading) Accuracy

1st to 12th (h01- h12)99.9%

5% + 10

13th to 25th (h01- h12) 10% + 10

Maximum input voltage and current: approx. 1000 Vrms, 600 Arms

The “rdy” is displayed at ACV < 10 Vrms, ACA < 10 Arms

The “OutF” is displayed at f < 45, 65 < f (f: fundamental frequency)

Inrush Current

Function RangeResolution

(Maximum reading)Accuracy

ACA100 A 99.99 A 2.5% + 20

600 A 600.0 A* 2.5% + 5

Maximum input current: approx. 600 Arms*600 A : Guaranteed accuracy (not maximum reading)100 A range: ACA1 ≥ 10 Arms (Sine wave, 50 Hz/60 Hz)

600 A range: ACA ≥ 100 Arms (Sine wave, 50 Hz/60 Hz)Measurement time: approx. 100ms

Active Power

Function RangeResolution

(Maximum reading)Accuracy

ACWDCW

10 kW 9.999 kW*ACW: 2.5% + 11**DCW: 2.2% + 22**

100 kW 99.99 kW

600 kW 600.0 kW**

* The measured value < 1.000 kW: add 10 digits to the accuracy.

**Conditions of accuracy (combination of Voltage and Current range)10 kW range: 100 V and 100 A100 kW range: 100 V and 600 A or 1000 V and 100 A600 kW range: 1000 V and 600 AOther combinations:Accuracy: (Current accuracyVoltage reading) + (Voltage

accuracyCurrent reading)

**600 kW : Guaranteed accuracy (not maximum reading)Maximum input voltage and current: 1000 Vrms, 600 ArmsACW: ACV ≥ 10 Vrms and ACA ≥ 5 Arms (Sine wave, 50 ≤ f ≤ 60 Hz, PF=1.00)DCW: at DCV ≥ 10 V and DCA ≥ 5 A

Power Factor

Function Resolution (Measuring range) Accuracy

Power factor -1.00 to 0.00 to 1.00 ±(3º+2digits)

Maximum input voltage and current: 1000 Vrms, 600 Arms

PF: ACV ≥ 10 Vrms and ACA ≥ 5 Arms (Sine wave, 50 ≤ f ≤ 60 Hz)

Resistance/Continuity check

Function RangeResolution

(Maximum reading)Accuracy

Resistance Ω1000 Ω 999.9 Ω 1.0% + 5

10 kΩ 9.999 kΩ1.0% + 3

100 kΩ 99.99 kΩ

Continuity check1000 Ω 999.9 Ω 1.0% + 5

The buzzer turns on for resistances lower than approx. 30 Ω. (Response time: approx. 100 msec)

Maximum input voltage: 1000 VrmsMaximum test current: approx. 0.5 mAOpen circuit voltage: approx. 3 V

Diode Test

Function Resolution (Measuring range) Accuracy

Diode Test 0.40 to 0.80 V ±0.1 V

Maximum test current: approx. 0.5 mA

Open circuit voltage: approx. 1.8 V

General SpecificationsDisplay count: 9999 / 6000

Measuring rate: 3 times / sec.

Over range indicator: “OL” or “-OL”

Auto Power Off: Approx. 15 minute.

Low-battery indicator: (four steps)

Power supply: 9 V alkaline battery (6LR61)

Battery life: When using alkaline battery, backlight off

Approx. 20 hours

Operating temperature and humidity: 0 to 50˚C (with no condensation)

≤ 80% RH (0 to 30˚C)

≤ 75% RH (30 to 40˚C)

≤ 45% RH (40 to 50˚C)

Temperature coefficient: At 0 to 18 ˚C and 28 to 50˚C

Add 23±5 ˚C accuracy x 0.2 /˚C

Storage temperature: -10 to 50 ˚C, 80% RH or less (remove the battery)

Withstand voltage: AC 6880 Vrms 5 sec. (between the core and the case)

AC 4300 Vrms 5 sec. (between the core and the voltage input terminals)

AC 6880 Vrms 5 sec. (between the voltage input terminals and the case)

Insulation resistance: 100 MΩ or greater at 1000 VDC

(between the core and the case, the core and the voltage input

terminals and the voltage input terminals and the case)

Compliant standards:

Safety standards: EN 61010-1, EN 61010-2-032

1000V CAT.III, 600V CAT.IV

EN 61010-031 (the test leads)

Pollution degree 2, Indoor use, Altitude 2000m or less

EMC standards: EN 61326-1, EN 61326-2-1, EN 61326-2-2, EN 55011

Dimensions: Approx 87.5 mm(W) × 242 mm(L) × 51 mm(D)

Diameter of measurable conductors: ϕ 37mm (Maximum)

Weight: Approx. 435 g (including the battery)

Accessories: Test leads 1 set (Red and Black)

Carrying case

9 V alkaline battery (6LR61)

User’s Manual

Accessories (Sold Separtely): Lead with Alligator Clip Model code 99014

67

68

Dig

ital M

ultim

eter

Digital Multi Meter

7533

serie

s

7534

serie

s

3.5 Digits4.5 Digits

TY720

TY710

TY530

TY520

73201

73202

73203

73101

Existing

model

Disco

ntin

ued

prod

ucts

for r

epla

cing

7340

1

7310

1

7532

01

7532

02

7532

03

7537

01

7537

02

7537

03

7537

04

7538

01

7330

3

7330

2

7330

1

7544

01

7544

02

7340

2

Handheld Digital Multi Meter Sellection

Simple selection for replacing discontinued products

Handhel Digital Multi Meter Models

Function item TY710 TY720 TY520 TY530 73201 73202 73203 73204 73101

Measurment Function Ture RMSTure RMS MEAN

SellectRMS

RMS MEAN

SellectMEAN MEAN MEAN MEAN MEAN

Max. Measurrement Accuracy at DCV 0.02% 0.09% 0.5% 0.5% 0.3% 0.5% 0.7%

Wide bandwidth 20 KHz 100 KHz 1 kHz — —

Display Digits(Uint:Digit) 5 digits 3.5 Digits 3.5 Digits 3.5 Digits

Max. Value 50000 6000 4300 4300

Bar Graph Dsiplay (Uints:Segment) 51 31 — 32

LCD Back Light White LED LED — —

Max.Measurement Voltage (AC/or DC)

50.000 mV

to

1000.0 V

50.000 mV

to

1000.0 V

600.0 mV

to

1000 V

600.0 mV

to

1000 V

4.000 V*3

to

600 V

4.000 V*3

to

600 V

4.000 V*3

to

600 V

4.000 V*3

to

600 V

4.000 V*3

to

600 V

Max.Measurement Currents (AC/or DC)

500.00 μA

to

10.000 A

500.00 μA

to

10.000 A

600.0 μA

to

10.00 A

600.0 μA

to

10.00 A

400.0 μA

to

10.00 A

400.0 μA

to

10.00 A

400.0 μA

to

10.00 A

— —

Max.Measurement Resistance

500.00 Ωto

50.000 MΩ

500.00 Ωto

50.000 MΩ

600.0 Ω

to

60.00 MΩ

600.0 Ω

to

60.00 MΩ

400.0 Ωto

40.00 MΩ

400.0 Ωto

40.00 MΩ

400.0 Ωto

40.00 MΩ

400.0 Ωto

40.00 MΩ

400.0 Ωto

40.00 MΩ

Max.Measurement Frequency

2.000 Hz

to

99.99 kHz

2.000 Hz

to

99.99 kHz

10.00 Hz

to

99.99 kHz

10.00 Hz

to

99.99 kHz

— — — — —

Max.Measurement Capcitance

5.000 nF

to

50.00 mF

5.000 nF

to

50.00 mF

10.00 nF

to

1000 μF

10.00 nF

to

1000 μF

20.00 nF

to

200.0 μF

20.00 nF

to

200.0 μF

— —

Max.Measurement Temperature +1372°C*1 +1372°C*1 +600°C*1 +600°C*1 — — — — —

Duty Ratio (%) Measuement — — — — — — —

Low-Power — — — — — — — —

AC+DC Measurement — — — — — — —

Max./Min./Ave. Value Memory — — — — — —

Diode Test

Continuity Check

Relative/Percentage (%) calculation — — — — —

Decibel calculation — — — — — —

Selection Auto range or Manual range —

Peak Hold — — — — — — — —

Data Hold *2

Auto Hold

Communication for PC *2 *2 — *2 — — — — —

Data Logging Memory *2 *2 — *2 — — — — —

Data Memory 1000 10000 — 1600 — — — — —

Operating Temp. and Humidity -20 to 55°C -20 to 55°C -10 to 55°C -10 to 55°C 0 to 50°C 0 to 50°C 0 to 50°C 0 to 50°C 0 to 50°C

Electric Safety 1000 V CAT III CAT III — —

Electric Safety 600 V CAT IV CAT IV CAT II CAT III CAT III

Electric Safety 300 V — — CAT III — CAT II

*1 Temperature probe is necessary when measuring temperature.*2 The communications package (model: 92015) for DMM is necessary when connecting it with PC. *3 73101,732 Series minimum range of DCvoltage is 400.0 mVDC.

69

Dig

ital M

ultim

eter

Digital Multi Meter

A New De Facto Standard for Handheld DMM

TY700 SeriesDigital Multimeters

• Maximum Measurement Accuracy: 0.020% rdg + 2 dgt • Highly Reliable: Closed case calibration• Full Support of Data Management: Measured data stored in internal memory• Safe Design: Shutters prevent erroneous insertion of test leads into current

measurementterminals (terminal shutters)

• Shockproof elastomer casing

• Wide operating temperature range: -20 °C to 55°C

General SpecificationsAdditional Functions USB communication (optional adapter & software),

data memory (TY720: 10,000 data, TY710: 1,000 data), max/min value memory, relative/percentage value computation, logarithm computation, data/auto hold, peak hold (TY720), overvoltage warning, backlight

Power Supply Four AA (R6) dry cellsBattery Life Approx. 120 hoursDimensions 90 (W) × 192 (H) × 49 (D) mmWeight Approximately 560 g (including batteries)Safety Standards 1000 V CAT. 3, 600 V CAT. 4

Features

• Data saved in the internal memory PC transfer is possible (Save memories or Logging Memories)• DMM measurements show in real time monitor display is possible.• Large amounts of data not covered by the internal memory PC communication with data transfer is possible. At the same time Excel transferable is also. Maximum incoming data: 32767

• Measurement data to Excel direct deployment is possible. Automatically creates a chart sheet.

DMM of dedicated application software (Model: 92015 )

DMM’s and you can easily manage the data in memory. Is also capable of real-time communications

92015 product specification:

Communication cableCommunications cable: infrared communication adapter +

communications cable (USB specifi-cations) 2 m length

Interface standards: USB specification conforms to the 1.1 Available models : TY710, TY720, TY530

Application software

Operating environment of the personal computerOS: Windows XP / Vista / 7 CPU: Pentium 133 MHz or higherMemory: 64 MB Hard disk has free space or more storage: 10 MB Over, CD drive Excel: since the Excel2000 Software: CD, communication cable (including adapter),

User’s manual

TY710 TY720

Detection RMS Switching detection (RMS or MEAN)

Item Range Accuracy

DCV

50 mV 0.05 + 10

500 mV/2400 mV 0.02 + 2

5 V 0.025 + 5

50 V/500 V/1000 V 0.03 + 2

ACV

[RMS]

Upper: 10 to 20 Hz

Lower: 20 Hz to 1 kHz

Upper: 1 kHz to 10 kHz

Lower: 10 kHz to 20 kHz

Upper: 20 kHz to 50 kHz

Lower: 50 kHz to 100 kHz

Upper: 10 to 20 Hz

Lower: 20 Hz to 1 kHz

Upper: 1 kHz to 10 kHz

Lower: 10 kHz to 20 kHz

Upper: 20 kHz to 50 kHz

Lower: 50 kHz to 100 kHz

50 mV—

2 + 80

0.4 + 40

5 + 40

5.5 + 40

15 + 40

15 + 40

50 mV/5 V/

50 V/500 V 1.5 + 30

0.7 + 30

0.7 + 30

2 + 50

— 1 + 30

0.4 + 30

0.4 + 30

1 + 40

2 + 70

5 + 200

1000 V3 + 30

3 + 30

ACV

[MEAN]

10 to 20 Hz 20 Hz to 500 Hz 500 Hz to 1 kHz

50 mV — 4 + 80 1.5 + 30 5 + 30

50 mV/5 V/

50 V/500 V/1000 V— 2 + 30 1 + 30 3 + 30

DCV + ACV

Upper: DC, 10 to 20 Hz

Lower: DC, 20 Hz to 1 kHz

Upper: DC, 1 kHz to 10 kHz

Lower: DC, 10 kHz to 20 kHz

Upper: DC, 20 kHz to 50 kHz

Lower: DC, 50 kHz to 100 kHz

Upper: DC, 10 to 20 Hz

Lower: DC, 20 Hz to 1 kHz

Upper: DC, 1 kHz to 10 kHz

Lower: DC, 10 kHz to 20 kHz

Upper: DC, 20 kHz to 50 kHz

Lower: DC, 50 kHz to 100 kHz

5 V/50 V/500 V1.5 + 10

1 + 10

1 + 10

2 + 10

1.5 + 10

0.5 + 10

0.5 + 10

1 + 10

2 + 10

5 + 20

1000 V1.5 + 10

1 + 10

1.5 + 10

0.5 + 10

DCA

500 μA/5000 μA/

50 mA/500 mA0.2 + 5

5 A 0.6 + 10

10 A 0.6 + 5

ACA

[RMS]

10 Hz to 20 Hz 20 Hz to 1 kHz 1 kHz to 5 kHz 10 Hz to 20 Hz 20 Hz to 1 kHz 1 kHz to 5 kHz

500 μA/5000 μA/

50 mA/500 mA 1.5 + 20 1 + 20 —1 + 20 0.75 + 20 1 + 30

5 A/10 A 1.5 + 20 1 + 20 2 + 30

ACA

[MEAN]

10 Hz to 20 Hz 20 Hz to 1 kHz 1 kHz to 5 kHz

500 μA/5000 μA/

50 mA/500 mA— 2 + 20 1.5 + 20 2 + 30

5 A/10 A — 3 + 20 2 + 20 4 + 30

DCA + ACA

DC, 10 to 20 Hz DC, 20 Hz to 1 kHz DC, 1 kHz to 5 kHz DC, 10 to 20 Hz DC, 20 Hz to 1 kHz DC, 1 kHz to 5 kHz

500 μA/5000 μA/

50 mA/500 mA 2 + 10 1.5 + 10 —1.5 + 10 1 + 10 1.5 + 10

5 A/10 A 2 + 10 1.5 + 10 3 + 10

Resistance

500 Ω/5 kΩ/50 kΩ500 kΩ 0.1 + 2 0.05 + 2

5 MΩ 0.5 + 2

50 MΩ 1 + 2

Low-power

Resistance

5 kΩ/50 kΩ/500 kΩ — 0.2 + 3

5 MΩ — 1 + 3

Frequency 2.0 Hz to 99.99k Hz 0.02 + 1

Capacitance

5 nF/50 nF/500n F

5 μF/50 μF1 + 5

500 μF 2 + 5

5 mF/50 mF 3 + 5

Continuity check 550 Ω Buzzer sounds at 100±50 Ω or less

Diode test 2.4 V 1 + 2

Temperature -200 to 1372°C 1 + 1.5°C

70

Dig

ital M

ultim

eter

Digital Multi Meter

73101Pocket Digital Multimeter

4300 count displayContinuity Check and Diode TestAuto HoldAuto Power Off

73101 Specifications

Accuracy: (23°C ±5°C, Less than 80% RH), ±(% rdg + dgt)

Pocket DMM with Superb Portability

732 SeriesDigital Multimeters

3.5 digits (4,300-count), Mean value typeMeasurement Functions: Voltage, Current, Resistance, Continuity Check, Diode Test, CapacitanceFeatures: Auto hold, Auto power-off

Low-cost Handheld DMM

Provides Safety Levels Demanded in Field Work

Model 73201 73202 73203 73204

Detection Mean value

Item Range Accuracy

DCV400.0 mV/4.000 V/40.00 V/400.0 V/600 V

0.5% + 10.75% + 1

0.5% + 1 0.3% + 1 0.5% + 1

ACV4.000 V/40.00 V/400.0 V/600 V

1.0% + 5 0.75% + 5

DCA400.0 μA/4000 μA/40.00 mA/400.0 mA/10.00 A

1.0% + 22.0% + 2

ACA(40 to 500 Hz)

400.0 μA/4000 μA/40.00 mA/400.0 mA/10.00 A

2.0% + 202.0% + 52.0% + 202.0% + 52.0% + 20

Resistance400.0 Ω/4.000 kΩ/40.00 kΩ/400.0 kΩ/4.000 MΩ/40.00 MΩ

0.75% + 20.75% + 12.0% + 15.0% + 2

Item Range Accuracy Input Resistance

DCV400.0 mV4.000 V

40.00/400.0/600 V

1.2% + 20.7% + 11.2% + 1

>100 MΩ11 MΩ10 MΩ

ACV4.000 V

40.00/400.0/600 V2.0% + 5 10 MΩ

Resistance

400.0 Ω4.000 k/40.00 k/400.0 kΩ

4.000 MΩ40.00 MΩ

1.2% + 22.0% + 35.0% + 3

Continuity check 400.0 Ω −

Diode test 2.00 V 1.5% + 1Open-circuit Voltage<3.4 V

Testing Current<1.0 mA

General Specifications • External dimensions: 74 (W) × 155 (H) × 31 (D) mm • Weight: Approx. 240 g • Power Supply: Two AAA (LR03 or R03) dry cells

732 Series Specifications

Accuracy: (23°C ±5°C, Less than 80% RH), ±(% rdg + dgt)

Genetal Specifications • External dimensions: 76 (W) × 117 (H) × 18 (D) mm • Weight : Approx. 110 g • Power Supply: Two LR-44 dry cells

TY500 SeriesDigital Multimeters

3.5 digits (6,000-count, 31-segment bar graph display), RMS typeMeasurement Functions: Voltage, Current, Resistance, Continuity Check, Diode Test, Frequency, Capacitance, TemperatureFeatures: Closed case calibration, Hi-impact overmold case, USB communication (optional adapter & software) (TY530 only), data memory (1,600 data for TY530 only)Safety Standards: 1000 V CAT. 3, 600 V CAT. 4

General Specifications • External dimensions: 90 (W) × 192 (H) × 49 (D) mm • Weight : Approx. 570 g • Power Supply: Four AA (R6) dry cells

TY500 Series Specifications

Accuracy: (23°C ±5°C, Less than 80% RH), ±(% rdg + dgt)

TY520 TY530

Detection RMS Switching detection (RMS or MEAN)

Item Range Accuracy

DCV

600 mV/6 V/60 V/600 V

0.09 + 2

1000 V 0.15 + 2

ACV

50/60 Hz 40 to 500 Hz 500 Hz to 1 kHz

600 mV/6 V/60 V/600 V1000 V

0.5 + 5 1 + 51.5 + 5

DCA600 μA/6000 μA/60 mA 0.2 + 2

600 mA/6 A/10 A 0.5 + 5

ACA

50/60 Hz 40 Hz to 1 kHz

600 μA/6000 μA/60 mA/600 mA/6 A/10 A

0.75 + 5 1.5 + 5

Resistance

600 Ω/6 kΩ/60 kΩ/600 kΩ 0.4 + 1

6 MΩ 0.5 + 1

60 MΩ 1 + 2 (0 to 40 MΩ)2 + 2 (40 to 60 MΩ)

Frequency 10.0 Hz to 99.99 kHz 0.02 + 1

Capacitance

10 nF 2 + 10

100 nF/1 μF/10 μF 2 + 5

100 μF/1000 μF 3 + 5

Continuity check 600 Ω Buzzer sounds at 50±30 Ω or less

Diode test 2 V 1 + 2

Temperature -50 to 600°C 2 + 2°C

71

Dig

ital M

ultim

eter

Digital Multi Meter

93029

RD031

323

110 50 10

1200 50

ϕ 3.2 ϕ

22

ϕ 14

90050200

50 10

1200

ϕ 1

.6 ϕ 22

ϕ 14

150

273

110

9005150

26

14

30 110

178

6

50 10

1200

ϕ 15

ϕ 6.0

ϕ 14

9005550

13.5

177.5

30 110 50 1025.5

5.5

1200

ϕ 15

ϕ 6.0

ϕ 14

90056

96095

9807392015

Specifications

96095Model

ϕ 12mm

AC10 mV/A(AC 1 to 1300 mVrms)50/60 Hz

1.2% + 0.4 mV

-30 to 70°C relative Humidity 85% or less (no condensation)

Low battery warning: 2.2 V±0.2 V or less red LED flash1.9 V±0.2 V or less Power off

Approx. 35 Hours till a low battery indicator flashes*1

Dimensions&Weight127 (L) × 42 (W) × 22 (D) mm

Cord length: Approx.1200 mm Weight: Approx 140 g

EN61010-1: CAT3Pollution degree2, Altitude 2000 m or less for indoor use

EN61326-1: ClassB,EN61326-2-032

*1 From low battery warning to power off is about 5hours

Conductor Size

Measurement range

AC 0.1 to 130 A

DC 0 to ±180 A

General specifications

Output voltage Accuracy (at 23°C±5°C)

Operating Temp&Humidity range

Storage Temp&Humidity range

Power source

DC3 V(Size AAA alkaline Battery LR03 × 2 pcs)

Continuous use

Applicable standards

Accessories Soft case(94030),Battery,User’s Manual

-10 to 55°C relative Humidity 85% or less (no condensation)

2.5% + 0.4 mV

40 Hz to 1 kHz

1.2% + 0.4 mVDC10 mV/A (DC 0 to ±1800 mV)

96095AD/DC Clamp-on Probe

• Light and compact, easy to carry and easy to clamp on crowded wirings.

• Expands measuring span of currents and assure safety when measuring with any kind of DMM.

96001

Standerd Accessories

Applicable DMM Models

TY700 TY500 732

Name Model Specification TY710 TY720 TY520 TY530 01 02 03 04

Communication Package forDigital Multimeters

92015 Communication Adapter for USB+cable+Application Software

Test leads with Alligator Clip 990141000V CAT# 600V CAT$Red/Black(1 set)

Alligator Clips B9646HF Red/Black(1 set)

Rubber Case 93007

Carrying Case 93029 Hard case

B9646GB Hard case

Temperature Probe (Thermocouple type K)(Banana plag output)

90050 -50 to 150°C for liquld

90051 -50 to 600°C for liquld

90055 -20 to 250°C for surface

90056 -20 to 500°C for surface

Currents Clamp-on probe 96001 For 400 AAC Output: AC10 mV/A*1

96095For 130 AAC/180 ADCOutput: AC10 mV/A or DC10 mV/A*2

*1 Please use it with the ACV range. It is necessary to read the indicated value in a different way as TY710 and the TY720,732 series. The example: In AC1V display = 100 A TY520 and TY530, it is possible to scale it. (Even 60 A or less display is possible in case of 96001. )*2 Please use it with ACV or DCV range. It is necessary to read the indicated value in a different way as TY710 and the TY720,732 series. The example: In AC1V display = 100 A TY520 and TY530, it is possible to scale it. (Even 60 A or less display is possible in case of 96095. )

Applicable DMM Models

TY700 TY500 732

Name Model Specification TY710 TY720 TY520 TY530 01 02 03 04

Test leads 98073 1000V CAT# 600V CAT $ Red/Black(1set)

RD031 L-plug, Red/Black(1 set)

Fuse 99015 440 mA/1000 V

99016 10 A/1000 V

F02 15 A/250 V

F05 500 mA/250 V

Accessorise

DMM Accessories

Cla

mp-

on T

este

r

72

Clamp-on Tester

CL220Clamp-on Tester

• ACA/DCA• ϕ 24• AC/40 to 300 A• DC/40 to 300 A

AC/DC Current Measurement

CL150/CL155Clamp-on Testers

• ACA• ϕ 54• AC/400 to 2000 A• AC V/DC V/Ω• DC Output• RMS for CL155

Wide Range of Current Measurement

ACA

ACV

DCV

Resistance

Item Range

400 A

2000 A (0 to 1500 A)

2000 A (1500 to 2000 A)

40/400/750 V

40/400/1000 V

400/4 k/40 k/400 k

1.0 + 3 (50/60 Hz)

2.0 + 3 (40 to 1 kHz)

1.0 + 3 (50/60 Hz)

3.0 + 3 (40 to 1 kHz)

3.0 (50/60 Hz)

1.0 + 2 (50/60 Hz)

1.5 + 3 (40 to 1 kHz)

1.0 + 2

1.5 + 2, Beep sound at less than 50 ±35

Accuracy

Accuracy: (23°C ±5°C, Less than 75% RH), ±(% rdg + dgt)

ACA

DCA

Item Range

40 A

300 A (20 to 200 A)

300 A (200 to 300 A)

40 A

300 A (20 to 200 A)

300 A (200 to 300 A)

1.0 + 4

1.5 + 4

3.0

1.0 + 4 (50/60 Hz)

2.5 + 4 (20 to 1 kHz)

1.5 + 4 (50/60 Hz)

2.5 + 4 (20 to 1 kHz)

3.5 (50/60 Hz)

4.0 (20 to 1 kHz)

Accuracy

Accuracy: (23°C ±5°C, Less than 85% RH), ±(% rdg + dgt)

CL150/CL155 Specifications CL220 Specifications

CL130/135Clamp-on Testers

• ACA• ϕ 33• AC/200 to 600 A• AC V/Ω• RMS for CL135

AC/DC Current Measurement

CL120Clamp-on Tester

• ACA• ϕ 24• AC/20 to 200 A

Light weight & compact design

ACA

Item Range

20 A

200 A

2.0 + 7 (50 to 1 kHz)

2.0 + 5 (50/60 Hz)

3.0 + 10 (40 to 1 kHz)

Accuracy

Accuracy: (23°C ±5°C, Less than 75% RH), ±(% rdg + dgt)

ACA

ACV

Resistance

Item Range

200 A

600 A

200 V/600 V

200 Ω

1.5 + 6 (50/60 Hz)

2.0 + 5 (40 to 1 kHz)

1.0 + 3 (50/60 Hz)

2.0 + 5 (40 to 1 kHz)

1.0 + 2 (50/60 Hz)

1.5 + 4 (40 to 1 kHz)

1.2 + 4, Beeps at below 30 Ω (continuity check)

1.5 + 4 (50/60 Hz)

2.0 + 5 (40 to 1 kHz)

1.5 + 4 (50/60 Hz)

2.0 + 5 (40 to 1 kHz)

1.0 + 2 (50/60 Hz)

1.5 + 4 (40 to 1 kHz)

Accuracy (CL130/CL135)

Accuracy: (23°C ±5°C, Less than 85% RH), ±(% rdg + dgt)

CL120 Specifications CL130/CL135 Specifications

ModelDiameter of measurable

conductorRange Accuracy

AC

curr

ent

DC

curr

ent

Leak c

urr

ent

DC

volta

ge

AC

volta

ge

Resi

sta

nce

Contin

uity

check

Fre

quency

True R

MS

Outp

ut

Data

hold

Peak h

old

Filt

er

CL120 ϕ 24 20 to 200 A 2.0 + 7

CL130 ϕ 33 200 to 600 A 1.5 + 6

CL135 ϕ 33 200 to 600 A 1.5 + 4

CL150 ϕ 54 400 to 2000 A 1.0 + 3

CL155 ϕ 54 400 to 2000 A 1.0 + 3

CL220 ϕ 24 400 to 300 A 1.0 + 4

CL235 ϕ 33 400 to 600 A 1.0 + 5

CL250 ϕ 55 400 to 2000 A 1.5 + 2

CL255 ϕ 55 400 to 2000 A 1.5 + 2

CL320 ϕ 24 20 mA to 200 A 2.0 + 4

CL340 ϕ 40 40 mA to 400 A 1.0 + 5

CL345 ϕ 40 40 mA to 400 A 1.0 + 5

30031A ϕ 40 3 mA to 60 A 1.0 + 5

30032A ϕ 40 3 mA to 60 A 1.0 + 5

CL360 ϕ 68 200 mA to 1000 A 1.0 + 2

CL420 ϕ 6 DC 20 to 100 mA 0.2 + 3

Cla

mp-

on T

este

r

73

Clamp-on Tester

Leakage Currents of 1 mA measurement

CL250/CL255Clamp-on Testers

• ACA/DCA• ϕ 55• AC/400 to 2000 A, DC/400 to 2000 A• AC V/DC V/Ω• DC Output• Hz, RMS for CL255

Wide Range of ACA/DCA measurement

CL235Clamp-on Tester

• ACA/DCA• ϕ 33• AC/400 to 600 A, DC/400 to 1000 A• AC V/DC V/Ω/Hz• RMS

RMS ACA/DCA measurement

ACA

DCA

ACV

DCV

Resistance

Frequency

Item Range

400/600 A

400/1000 A

40/400/600 V

40/400/600 V

400/4000 Ω10 to 3000 Hz

1.5 + 5 (50/60 Hz)

3.5 + 5 (40 to 1 kHz)

1.0 + 5

1.5 + 5 (50/60 Hz)

3.5 + 5 (40 to 1 kHz)

1.0 + 5

1.0 + 5, Beeps at below 20 Ω (continuity check)

1.5 + 5

Accuracy

Accuracy: (23°C ±5°C, Less than 75% RH), ±(% rdg + dgt)

DCA

ACA

Item Range

400/2000 A

400 A/2000 A (0 to 1000 A)

2000 A (1001 to 2000 A)

1.5 + 2

1.5 + 2 (50/60 Hz)

3.0 + 4 (40 to 500 Hz)

5.0 + 4 (500 to 1 kHz)

3.0 + 2 (50/60 Hz)

Accuracy

Accuracy: (23°C ±5°C, Less than 75% RH), ±(% rdg + dgt)

CL235 Specifications CL250 Specifications

CL320Leakage Clamp-on Tester

• ACA• ϕ 24• AC/20 mA to 200 A

Compact design of Leakage current measurement

ACA

Item Range

20 mA/200 mA

200 A (0 to 100 A)

200 A (100.1 to 200 A)

2.0 + 4 (50/60 Hz)

5.0 + 6 (40 to 400 Hz)

5.0 + 4 (50/60 Hz)

3.0 + 5 (50/60 Hz)

5.0 + 5 (50/60 Hz)

Accuracy

WIDE (40 to 400 Hz) 50/60 Hz

Accuracy: (23°C ±5°C, Less than 85% RH), ±(% rdg + dgt)

CL320 Specifications

CL340/CL345Leakage Clamp-on Testers

• ACA• ϕ 40• AC/40 mA to 400 A• RMS for CL345

Leakage current measurement

ACA

Item Range

40 mA/400 mA

400 A (0 to 350 A)

400 A (350 to 400 A)

2.5 + 10 (20 to 1 kHz)

2.5 + 10 (40 to 1 kHz)

5.0 (40 to 1 kHz)

1.0 + 5 (50/60 Hz)

1.0 + 5 (50/60 Hz)

2.0 (50/60 Hz)

Accuracy

WIDE (20 Hz) 50/60 Hz

Accuracy: (23°C ±5°C, Less than 85% RH), ±(% rdg + dgt)

CL340 Specifications

CL360Leakage Clamp-on Tester

• ACA• ϕ 68• AC/200 mA to 1000 A• DC/AC Output

Wide Range of Leakage current measurement

ACA

Item Range

20 mA/2 A/20 A

200 A

1000 A (0 to 500 A)

1000 A (501 to 1000 A)

1.0 + 2 (50/60 Hz)

3.0 + 2 (40 to 1 kHz)

1.5 + 2 (50/60 Hz)

3.5 + 2 (40 to 1 kHz)

1.5 + 2 (50/60 Hz)

3.5 + 2 (40 to 1 kHz)

5.0 (50/60 Hz)

10.0 (40 to 1 kHz)

1.5 + 2

2.0 + 2

2.0 + 2

5.5

Accuracy

WIDE (40 to 1 kHz) 50/60 Hz

Accuracy: (23°C ±5°C, Less than 85% RH), ±(% rdg + dgt)

CL360 Specifications

DCA

ACA

Item Range

400/2000 A

400 A/2000 A (150 to 1700 A)

2000 A (1701 to 2000 A)

1.5 + 2

1.5 + 3 (50/60 Hz)

3.0 + 4 (30 to 1 kHz)

3.5 + 3 (50/60 Hz)

Accuracy

Accuracy: (23°C ±5°C, Less than 75% RH), ±(% rdg + dgt)

CL255 Specifications

ACA

Item Range

40 mA/400 mA

400 A (0 to 300 A)

400 A (300 to 400 A)

2.5 + 10 (20 to 1 kHz)

2.5 + 10 (40 to 1 kHz)

5.0 (40 to 1 kHz)

1.0 + 5 (50/60 Hz)

1.0 + 5 (50/60 Hz)

2.0 (50/60 Hz)

Accuracy

WIDE (20 Hz) 50/60 Hz

Accuracy: (23°C ±5°C, Less than 85% RH), ±(% rdg + dgt)

CL345 Specifications

30031A/30032ALeakage Clamp-on Tester

• ACA• ϕ 40• AC/3 mA to 60 A

ACA

Item Range

0 to 30 mA

0 to 50 A

50 to 60 A

1.0 + 5 (50±1.0 Hz/60±1.0 Hz)

5.0 + 5 (50±1.0 Hz/60±1.0 Hz)

1.5 + 5 (50±1.0 Hz/60±1.0 Hz)

5.5 + 5 (50±1.0 Hz/60±1.0 Hz)

Accuracy

30031 A, 30032 A Filter OFF 30032 A Filter ON

Accuracy: (23°C ±5°C, Less than 80% RH), ±(% rdg + dgt)

30031A/30032A Specifications

CL420Clamp-on Process Meter

• DCmA• ϕ 6• DC/20 mA to 100 mA• DC Output

DC signals of 4 to 20 mA measurement

DCmA

Item Range

20 mA

100 mA

0.2 + 5

1.0 + 5

Accuracy

Accuracy: (23°C ±5°C, Less than 80% RH), ±(% rdg + dgt)

CL420 Specifications

Insu

latio

n Tes

ter

74

Insulation Tester

Selection Guide

Two choices:Choose an analog model if visual recognition is of utmost importance, or a digital model if precise numeric recognition is of utmost importance.

Type

A wide choice of voltage/resistance ratings, from 25 V/5 MΩ to 1000 V/2000 MΩSome models have two or three ranges; thus, you need not take more than one instrument to the site.

Ratings

Each series includes a model or models with a backlight for working in dark places. Multifunc-tional models are capable of AC voltage measurement also.

Functionality

Optional test probes and probe tips are available for a variety of test environments.

Accessories

Points on How to Choose an Insulation Tester

3 1/2-digit

LCD

Automatic discharge

Conductor resistancemeasurement

Comparator function

Memory function

P.75

125 V/200 MΩ250 V/200 MΩ500 V/2000 MΩ1000 V/2000 MΩ

Automatic discharge

Battery check

Automatic discharge

Battery check

Battery check

P.76

P.76

3213A

Dig

ital in

su

latio

n te

ste

rsA

nalo

g in

su

latio

n te

ste

rs

4

ranges

2 & 3

ranges

Single

range

Single

range

Analog

Analog

Analog

MY40

2406E

MY10

Type RatingSuffix Code

& Backlight

Series/

ModelDisplay Additional Function External View Page

AC VoltageMeasuring range

25 V/5 ΜΩ

50 V/10 ΜΩ

125 V/20 ΜΩ

125 V/20 ΜΩ

250 V/50 ΜΩ

125 V/20 ΜΩ

250 V/50 ΜΩ

500 V/100 ΜΩ

250 V/50 ΜΩ

500 V/100 ΜΩ

1000 V/2000 ΜΩ

250 V/500 ΜΩ

500 V/1000 ΜΩ

1000 V/2000 ΜΩ

125 V/20 ΜΩ

250 V/50 ΜΩ

500 V/100 ΜΩ

500 V/1000 ΜΩ

1000 V/2000 ΜΩ

100 V/20 ΜΩ

250 V/50 ΜΩ

500 V/100 ΜΩ

500 V/1000 MΩ

1000 V/2000 MΩ

31

41 (EL-illuminated)

32

42 (EL-illuminated)

33

43 (EL-illuminated)

34

44 (EL-illuminated)

35

45 (EL-illuminated)

01 (afterglow-illuminated)

02 (afterglow-illuminated)

03 (afterglow-illuminated)

04 (afterglow-illuminated)

05 (afterglow-illuminated)

41

42

43

44

45

01 (EL-illuminated) 0 to 600 V

0 to 300 V

0 to 300 V

0 to 600 V

0 to 600 V

0 to 600 V

0 to 250 V

0 to 300 V

0 to 500 V

0 to 500 V

0 to 500 V

0 to 150 V

0 to 250 V

0 to 300 V

0 to 300 V

0 to 300 V

P.76

Insu

latio

n Tes

ter

75

Insulation Tester

MY40Digital Insulation Tester

Features

• Multifunction Insulation resistance, AC voltage and conductor resistance measurement Insulation test mode: Comparator, memory, auto-hold and discharge functions All test modes: Live-line alarm (excluding AC voltage measurement), battery

check and automatic power-off• Easy-to-view, fluctuation-free display• Double-action safety mechanism

General Specifications

Dimensions: 125 (W) × 103 (H) × 53 (D) (mm)Weight: 420 g (main unit and batteries only)Batteries: Four AA (R6P) batteries

125 V/200 MΩ

250 V/200 MΩ

500 V/2000 MΩ

1000 V/2000 MΩ

MY40-01

.4000

4.000

40.00

200.0

.4000

4.000

40.00

200.0

4.000

40.00

400.0

2000

4.000

40.00

400.0

2000

.1 kΩ1 kΩ

10 kΩ100kΩ.1 kΩ1 kΩ

10 kΩ100 kΩ

1 kΩ10 kΩ

100 kΩ1 MΩ1 kΩ

10 kΩ100 kΩ

1 MΩ

0 to .0199 MΩ.0200 to 10.00 MΩ10.01 to 200.0 MΩ

0 to .0499 MΩ.0500 to 20.00 MΩ20.01 to 200.0 MΩ

0 to 0.999 MΩ1.000 to 500 MΩ501 to 2000 MΩ

0 to 1.999 MΩ2.000 to 1000 MΩ1001 to 2000 MΩ

± (5% of rdg+6 dgt)

± (2% of rdg+6 dgt)

± 5% of rdg

± (5% of rdg+6 dgt)

± (2% of rdg+6 dgt)

± 5% of rdg

± (5% of rdg+6 dgt)

± (2% of rdg+6 dgt)

± 5% of rdg

± (5% of rdg+6 dgt)

± (2% of rdg+6 dgt)

± 5% of rdg

0.125 MΩ

0.25 MΩ

0.5 MΩ

2 MΩ

1 mA

1 mA

1 mA

0.5 mA

5 MΩ

5 MΩ

50 MΩ

50 MΩ

Model RatingRangeOption

Resolution Measuring Range Tolerance Lower Limit ofmeasured Ω

RatedCurrent

Central ScaleValue

AC voltage measurement (45-400 Hz)

Conductor resistance measurement

Model Range Resolution Accuracy Input Impedance

MY40-01 1 V ±(2% of rdg + 6 dgt) Approx. 2 MΩ

Model Range Resolution Accuracy Open-circuit Voltage

Buzzer soundresistance: <40 Ω.

Standard test conditions

Ambient temperature/humidity ranges: 23 ±5°C/45-75% RH

Tolerances under the above-mentioned conditions:

Deviation from zero scale value: 6 digits maximum

Indication of ∞mark on bar graph: Approx. 4000 MΩ min. (500 V/1000 V)

Approx. 400 MΩ min. (125 V/250 V)

Open circuit voltage: 130% max. of rated voltage

Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range

Short-circuit Current: 2 mA max.

* First effective measuring range; ** The minimum value at which the rated voltage can be maintained

*

*

*

*

600 V

MY40-01 400 Ω 0.1 Ω ±(2% of rdg + 8 dgt)

Testing Performance Specifications

125 V/200 MΩ250 V/200 ΜΩ500 V/2000 ΜΩ1000 V/2000 ΜΩ

3213A

Dig

ital i

nsul

atio

n

test

ers

Ana

log

insu

latio

n te

ster

s

4ranges

2 & 3ranges

Singlerange

Singlerange

Type RatingSuffix Code(BackLight)

Series/Models

Series/Models References and notes

Existing products Discontinued products for replacing

25 V/5 ΜΩ50 V/10 ΜΩ125 V/20 ΜΩ125 V/20 ΜΩ250 V/50 ΜΩ125 V/20 ΜΩ250 V/50 ΜΩ500 V/100 ΜΩ250 V/50 ΜΩ500 V/100 ΜΩ1000 V/2000 ΜΩ250 V/500 ΜΩ500 V/1000 ΜΩ1000 V/2000 ΜΩ125 V/20 ΜΩ250 V/50 ΜΩ500 V/100 ΜΩ500 V/1000 ΜΩ1000 V/2000 ΜΩ100 V/20 ΜΩ250 V/50 ΜΩ500 V/100 ΜΩ500 V/1000 ΜΩ1000 V/2000 ΜΩ

31

41 (EL-illuminated)

32

42 (EL-illuminated)

33

43 (EL-illuminated)

34

44 (EL-illuminated)

35

45 (EL-illuminated)

01

02

03

04

05

41

42

43

44

45

01 (EL-illuminated)

240651 to 55*1

240661 to 65*1

3213D31 to D35*2

240631

240622

240626

240623/25

240621

321346

240301

240302

240305

321321

321322

321323

321324

321325

MY40

2406E

MY10

*1 2406D series is single or 2 range.

*2 3213D series is single range.

Digital model with 4 voltage/resistance ratings

Simple selection for replacing discontinued products

Insu

latio

n Tes

ter

76

Insulation Tester

2406E SeriesAnalog Insulation Testers

Analog models with two and three ratings

Features

• AC voltage measurement• Automatic discharge• Sky blue EL backlight• Increased safety (covered battery charger)

General Specifications

Dimensions (main unit): Approx. 120 (W) × 110 (H) × 60 (D) (mm)Weight: Approx. 500 g (including batteries)Batteries: Six AA (R6P) batteries

Testing Performance Specifications

MY10 SeriesAnalog Insulation Testers

Analog models with single rating

Features

• AC voltage measurement• Automatic discharge• A wide choice of accessories –Designed for shared use with the MY40

General Specifications

Dimensions: Approx. 125 (W) × 103 (H) × 53 (D) (mm)Weight: Approx. 400 g (main unit and batteries only)Batteries: Four AA (R6P) batteries

Testing Performance Specifications

Lower Limit ofMeasured Ω*

Model Rating Effective Measuring RangeCentral Scale

Value

AC VoltageMeasuring Range

Rated Current

125 V/20 MΩ250 V/50 MΩ

500 V/100 MΩ500 V/1000 MΩ

1000 V/2000 MΩ

0.5 MΩ1 MΩ2 MΩ

20 MΩ50 MΩ

0.01 to 20 MΩ0.01 to 50 MΩ

0.05 to 100 MΩ0.5 to 1000 MΩ

1 to 2000 MΩ

0 to 250 V

0 to 300 V

0 to 500 V

0 to 500 V

0 to 500 V

0.125 MΩ0.25 MΩ0.5 MΩ

1 MΩ2 MΩ

1 to 1.2 mA

1 to 1.2 mA

1 to 1.2 mA

0.5 to 0.6 mA

0.5 to 0.6 mA

MY10-01

MY10-02

MY10-03

MY10-04

MY10-05

* The minimum value at which the rated voltage can be maintained

3213A SeriesAnalog Insulation Testers

Analog models with single rating

Features

• AC voltage measurement and check live lines such as motive power lines• One-touch operation Press-and-lock switch for continuous measurement• A wide choice of accessories to meet various testing requirements• Vibration- and shock-resistant hand-held compact testers

General Specifications

Dimensions: Approx. 110 (W) × 180 (H) × 60 (D) (mm)Weight: Approx. 700 g including batteries, or approx. 1.2 kg including hard case,

handle, test leads and batteriesBatteries: Eight AA (R6P) batteries

Testing Performance Specifications

Lower Limit ofmeasured Ω Model Rating

EffectiveMeasuring Range

CentralScale Value

AC VoltageMeasuring Range

Rated Current

* The minimum value at which the rated voltage can be maintained; ** 0.55 mA in the case of the first effective measuring range

100 V/20 MΩ250 V/50 MΩ

500 V/100 MΩ500 V/1000 MΩ

1000 V/2000 MΩ

0.5M Ω1M Ω2M Ω

20M Ω50M Ω

0.02 to 20 MΩ0.05 to 50 MΩ0.1 to 100 MΩ1 to 1000 MΩ2 to 2000 MΩ

0 to 150 V

0 to 250 V

0 to 300 V

0 to 300 V

0 to 300 V

0.1 MΩ0.25 MΩ0.5 MΩ0.5 MΩ

1 MΩ

1 mA

1 mA

1 mA

1 mA**

1 mA**

321341

321342

321343

321344

321345

240632240642

240631

240641

240633

240643

240635

240645

240634

240644

25 V/5 MΩ50 V/10 MΩ

125 V/20 MΩ125 V/20 MΩ250 V/50 MΩ125 V/20 MΩ250 V/50 MΩ

500 V/100 MΩ250 V/50 MΩ

500 V/100 MΩ1000 V/2000 MΩ

250 V/500 MΩ500 V/1000 MΩ

1000 V/2000 MΩ

0.001 to 5 MΩ0.005 to 10 MΩ0.01 to 20 MΩ0.01 to 20 MΩ0.01 to 50 MΩ0.01 to 20 MΩ0.01 to 50 MΩ

0.05 to 100 MΩ0.01 to 50 MΩ

0.05 to 100 MΩ1 to 2000 MΩ

0.1 to 500 MΩ0.5 to 1000 MΩ

1 to 2000 MΩ

0.1 MΩ0.2 MΩ0.5 MΩ0.5 MΩ

1 MΩ0.5 MΩ

1 MΩ2 MΩ1 MΩ2 MΩ

50 MΩ10 MΩ20 MΩ50 MΩ

0.025 MΩ0.05 MΩ

0.125 MΩ0.125 MΩ

0.25 MΩ0.125 MΩ

0.25 MΩ0.5 MΩ

0.25 MΩ0.5 MΩ

1 MΩ0.25 MΩ0.5 MΩ

1 MΩ* The minimum value at which the rated voltage can be maintained;** 0.55 mA in the case of the first effective measuring range

0 to 300 V

0 to 300 V

0 to 600 V

0 to 600 V

0 to 600 V

Lower limit ofmeasured ΩModel Rating

EffectiveMeasuring range

CentralScale Value

AC VoltageMeasuring range

Rated Current

1 mA1 mA1 mA1 mA1 mA1 mA1 mA1 mA1 mA1 mA1 mA**1 mA**1 mA**1 mA**

Non-Back-LightEL-Back-Light

Insu

latio

n Tes

ter

77

Insulation Tester

Quick-reference Table of Accessories

58

9

ϕ 4

1 2

108

8

ϕ 3

1 3 2

360 ±5

1 3 2

32.5

68

1000 ±10

99011

B9600GN

B9600NZ

B9600NX

No. Description

Testing shank

Fastening nut

PVC-clad

1

2

3

Metal shank with ϕ 6 screw

ABS resin

Remarksϕ 3

105

Note that the color of the plastic part of a probe tip may not always match that of the probe, depending on the combination.

*1 Regarding external dimensions of cases, Pls refer to each product specification.

*2 For using with MYSeries, 98052 is necessary.

98007

Line probe

Earth probe

125

32.5 1000 ±10

160

ϕ 26

Probes Unit: mm

55 16

11 16 1000

3218 03B9303XE

Spare Probe Tips Others Unit: mmUnit: mm

98050

Series/Model 3213A 2406E MY10 MY40

For breaker pins

General-purpose

Extended

Sharp-pointed

Line probe

Earth probe

Measuring Lead unit (Paired earth/line terminals)

Replaceable type Line Probe

Bag for housing spare probe tips

Accessory-housing case

Carrying case

Protection cover

Shoulder strap

Handle

Lead for guard terminals

98050

B9600NV

B9646CA

B9600HA

w/accessory-

housing case

B9303XE

98007

Earth and Line probes

B9108XA

93015

Store main unit

/accessories

93015

Store main unit

/accessories

Note: Includes an accessory-housing case.

B9075MU(hard case)

B9075MV(soft case)

321803

B9600GN

B9600NX

B9600NZ

99011

B9600GN *2

B9600NX *2

B9600NZ *2

98001

98002

B9108XA

93013

99005

Spare

probe tip

Case

*1

Probe

Others

980011200mm

980021200mm

(176)

(78)

1000±10

85

35.4

20

1000±10

Eart

h Tes

ter,

Oth

er P

rodu

cts

78

Earth Tester/Leakage Current Tester/Illuminance Meter

Earth Tester Capable to Measure by 3 Pole or 2 Pole Method

322610Leakage Current Tester

• Three input resistance ranges – 1, 1.5 and 2 kΩ • Four functions – AC current, DC current, DC + AC current and AC voltage measurements• ±2.5% full scale accuracy• 100 μA full scale value• Shockproof indicator using taut band movement• Built-in overload protection circuit• Handy and easy to carry• Shielded case, resistant to high-frequency fields

322610 Specifications

Range: DC current ... 0.1, 1, 10 mA, AC current .... 0.1, 1, 10 mA, (DC + AC) current ... 0.1, 1, 10 mA, AC Voltage ... 150, 300 V (50 and 60 Hz) Accuracy: ±2.5% of full scale value on current and voltage rangesInput Impedance: Current range; 1 kΩ, 1.5 kΩ, and 2 kΩ Voltage range; More than 100 kΩFrequency Range: 20 Hz to 5 kHzPower Source: Two 9 V dry cells, Continuous Operating Time; Approx. 290 hoursOverload Protection: Up to 30 mA AC for one minute will not damage instrument on current

rangesDimensions: Approx. 190 × 124 × 90 mm not including handleWeight: Approx. 1.0 kg

Handy Universal Tester for Checking Electrical Appliances

510 SeriesDigital Lux Meter

• Wide range, High Accuracy• Average illuminance computation function• Timer hold• USB communication

510 Series Specifications

Photoelectric Element: Silicon PhotodiodeMeasuring Range: 0.0 to 99.9/999/9,990/99,900/999,000lXResponse Time: 5 sec. (Auto Range) 2 sec. (Manual Range)Accuracy: ±4% rdg. ±1 dgt. (51011)

±2% rdg. ±1 dgt. (51012, 51021)General Specifications • External dimensions (main unit): Approx. 67 (W) × 177 (H) × 38 (D) (mm) • Weight: Approx. 260 g • Batteries: AA (LR6) × 2

Excellent Performance, Multiple Functions

EY200Digital Earth Tester

• Capable to measure by 3-pole or 2-pole measuring• Easy to measure with one touch button and dedicated test lead• Small and lightweight• Dust and drip proof (designed to IEC60529 IP54)

EY200 Specifications

Display LCD Digital Display: 1999-count digital readingMeasuring Range Earth Resistance: 2000 Ω LSD: 0.01 to 1 Ω Earth Voltage: 200 VAccuracy Earth Resistance: 20 Ω range: ±2%rdg±0.1 Ω 200 Ω range: ±2%rdg±3 dgt 2000 Ω range: ±2%rdg±3 dgt Earth Voltage: ±1%rdg±4 dgtMeasuring Frequency Approx. 820 HzMeasuring Current Approx. 3 mA (at 20 Ω range)Battery Life Approx. 4.5 hours (at 5 second measuring 3300 times)Operating Temp. 0 to 40°C, 85%Rh or lessand Humidity 0 to 40°C, 85%Rh or lessDimensions Approx. 105 × 158 × 70 mmWeight Approx. 550 g

Ther

mom

eter

79

Thermometer

TX10 SeriesDigital Thermometers

TX1001: 1-channel Single-function with data hold

functionTX1002: 1-channel Multifunction with data hold,

internal memory, user-calibration and relative display function

TX1003: 2-channel Multifunction with data hold,

internal memory, user-calibration and relative display function

TX10 Series Specifications

• Thermocouple measurement ranges Type K: -200 to 1372 deg.C Type J: -200 to 1000 deg.C Type E: -200 to 700 deg.C Type T: -200 to 400 deg.C • Resolution -200.0 to 199.9 deg.C: 0.1 deg.C, 200

deg.C: 1 deg.C (TX1001) -200.0 to 199.9 deg.C: 0.1 deg.C or 1

deg.C (when resolution is set at 1 deg.C), 200 deg.C: 1 deg.C (TX1002, 03) • Accuracy -200.0 to -100.1 deg.C: +/-(0.1% of rdg +

1.0 deg.C); -100.0 to 199.9 deg.C: +/-(0.1% of rdg +

0.7 deg.C); 200 deg.C and when resolution is set at

1 deg.C:+/-(0.2% of rdg + 1 deg.deg.C) General Specifications • External dimensions: 56 (W) × 151 (H) × 33 (D) mm • Weight: Approx. 180 g • Power: Two AA size (LR6) dry batteries

Simplified Thermometer with easy operation

TM20Thermo-collectors

• Effective for HACCP program implementation.• Collect up to 5000 data items with time-stamp, tag name and inspector name.• Save 2 weeks continuous data logging with 1 minute interval, (up to 20000 data items,

measuring interval is 1sec. to 24 houres.) Information on when, by whom and what is measured is saved along with the data.

Model

Temperature Probe (for type K)

90020

90021

90022

90023

90024

90030

90031

90032

90033

245907

rounded end

rounded end

rounded end

needle

needle

Surface straight

Surface angled

Surface straight

Surface angled

Bead TC

-50 to 600°C

-50 to 600°C

-50 to 600°C

-50 to 500°C

-50 to 500°C

-20 to 250°C

-20 to 250°C

-20 to 500°C

-20 to 500°C

-40 to 260°C

0.4% or ±1.5°C

0.4% or ±1.5°C

0.4% or ±1.5°C

0.4% or ±1.5°C

0.4% or ±1.5°C

0.75% or ±2.5°C

0.75% or ±2.5°C

0.75% or ±2.5°C

0.75% or ±2.5°C

0.75% or ±2.5°C

1.4

0.4

1.4

0.4

1

2

2

2

2

(90% response)

3.2 / 200

1.6 / 150

3.2 / 500

1.6 / 100

2.1 / 100

15 (temp. sensing portion)

15 (temp. sensing portion)

15 (temp. sensing portion)

15 (temp. sensing portion)

1200 (included cord)

Probe type Measuring range AccuracyResponse

time (second)Sensor

Dimenter / Length (m/m)

NOTE: 90030 is using polyimide to insulate from objects to be measured.Manufacturers of polyimide are announcing not to apply polyimide directly for food, internal and body fluid.

Probes for TM20/TX10

Dimensions

Approx. 151(H) × 56(W) × 33(D) mm

(excluding protrusions)

Weight: Approx. 180 g

(including batteries)

TM20 Thermo-collector

Thermocouple model

(54011)

Thermocouple Type K : -200°C to 1372°C

Type J : -200°C to 1000°C

Type E : -200°C to 700°C

Type T : -200°C to 400°C

Voltage input ±100 mV, ±1 V

2

Collector mode:

0.5 seconds or longer when 1 channel is used.

Logging mode:

1 second to 24 hours when 1 channel is used.

Thermocouple -200.0 to 100.1°C

: ±(0.1% of rdg + 0.7°C)

-100.0°C or above

: ±(0.1% of rdg + 1.0°C)

Voltage input ±(0.1% of rdg + 0.2% of range)

Product name

(Model)

Number of measuring

channels

Data capacity

Measuring range

(only the main unit)

Accuracy

(only the main unit)

Supplied accessories

Measuring

interval

External

dimensions

5000 data items when used in collector mode only,

20000 data items when used in logging mode only.

Software, two AA-size alkaline dry batteries (LR6), a waterproof cover, and an instruction manual

TM20 Specifications

Model

91011

Product name

RS-232C cable for PC connection (9-pin)

Optional Accessories for TM20

Handy temperature data logger

90033Material:SUS316

90021Material:SUS316

90022Material:SUS316

90023Material:SUS316

90024Material:SUS316

245907

90030Material:SUS316

90031

Material:SUS316

90020Material:SUS316

heat-resistantPVC

1200110200

22 143.2

13

heat-resistantPVC

1200110150 13

22 141.6

heat-resistantPVC

1200110500 13

22 143.2

heat-resistantPVC

1200110100 13

22 141.6

45°

siliconrubber

1200110100 13

22 142.1

45°

1200

siliconrubber

siliconrubber

1200110

1200110

56 12

55.5 12

26

14

25.5

13.5

22

6

22

6

1414

1515

siliconrubber

siliconrubber

1200110100 12

1200110100 12

4.8

4.8

15

15

2222

1414

4645

.5

14

2913

.5 28.5

90032Material:SUS316

Pre

cisi

onM

easu

ring

Inst

rum

ents

80

Precision Measuring Instruments

2769Portable Double Bridge

Model 2769 is a compact, portable Kelvin double bridge designed for measuring low resistance from 0.1 mΩ to 110 Ω with four multiplication plugs and one measuring dial. It has built-in standard resistors, bridge power source and high-sensitivity taut-band suspension system electronic DC galvanometer.

2769 Specifications

Measuring Range: 0.1 mΩ* to 110 Ω.Measuring Dial: 1.00 to 11.00 Ω at × 1.Multipliers: × 0.0001*, × 0.001, × 0.01, × 0.1, ×

1, × 10 (plug-in system).Min. Division: 0.005 mΩ at × 0.0001*,

0.05 mΩ at × 0.001, 0.5 mΩ at × 0.01, 5 mΩ at × 0.1, 50 mΩ at × 1, 0.5 Ω at × 10.

Accuracy: ± (0.05 Ω × multiplier + 0.01 mΩ) Current Rating: 10 A at × 0.0001*

(0.01 Ω), 3 A at × 0.001 (0.1 Ω), 1 A at × 0.01 (1 Ω). 0.3 A at × 0.1 (10 Ω), 0.1 A at × 1 (100 Ω), 0.01 A at × 10 (1,000 Ω).

Galvanometer: Built-in electronic DC galva-nometer, voltage sensitivity ... approx. 20 μV/div.

sensitivity changeover; G0 ... (Input resistance: approx. 11 kΩ). G1 ... approx. 1/11 of G0 sensitivity. G2 ... approx. 1/110 of G0 sensitivity.Operating Temperature Range: 5 to 35°CHumidity Range: Less than 85% Bridge Power Source: Tow 1.5 V batteries,

External power source is also usable.*Note: Standard Resistor (Model 2771) is re-

quired for measurement on 0.1 to 1.1 mΩ range at 0.0001 multiplier.

0.1 mΩ to 110 Ω with four plugs and one measuring dial

2755Portable Wheatstone Bridge

Model 2755 measures resistances from 1 Ω to 10 MΩ by operation of dials and switches. Batteries and a galvanometer are self-contained. The front control panel is provided with power and galvanometer circuit selectors, one ratio arm dial, and four measuring arm dials.

2755 Specifications

Measuring Range: 1,000 Ω to 10.00 Ω.Measuring Arms: 1 Ω × 10 + 10 Ω × 10 + 100

Ω × 10 + 1,000 Ω × 10 (min. one step: 1 Ω).Ratio Arms (Multiplier): × 0.001, × 0.01, ×

0.1, × 1, × 10, × 100, × 1,000 (M10, M100, M1000 ... Murray & Varley loop testing).

Accuracy: ±0.1% of reading on 100 Ω to

100 kΩ range, ±0.3% of reading on 10 Ω

to 1 MΩ range, ±0.6% of reading on 1Ω to

10 MΩ range.

Temperature Coefficient of Resistance Ele-ments: ±5 × 10-5/°C at ambient temperature of 5 to 35°C, ±2 × 10-5/°C at ambient temperature 20 to 35°C.

Galvanometer: Sensitivity ... 0.9 μA/div., inter-nal resistance ... Approx. 150 Ω, external critical damping resistance ... Approx. 800 Ω, period ... within 1.5 seconds.

Power Source: Three 1.5 V batteries (built-in).Operating Temperature Range: 5 to 35°C.Humidity Range: 85% max., relative humidity.Outer Case: ABS resin.Accessory supplied at no extra cost: Carrying case.

1 Ω to 10 MΩ by operation of dials and switches

278610/278620Decade Resistance Boxes

Models 278610 and 278620 six-dial decade resistance boxes allow quick and easy setting of a wide range of resistance. These resistance boxes are used in combination with voltage or current standards to adjust voltage or current, as dummy load resistances or as an arm of AC bridges.

278610/278620 Specifications

Available Models:

Model Number Resistance Range

278610 0.1 to 111,111 Ω (six decade dials)

278620 1 to 1,111,110 Ω (six decade dials)

Residual Resistance: Less than 23 mΩ.Power Rating: 0.3 W/step, within 3 W for

overall instrument.Maximum Allowable Input: 0.5 W/step, 5 W

for overall instrument.Maximum Circuit Voltage: 250 V.Operating Temperature Range: 0 to 40°C Storage Temperature Range: -10 to 50°C Humidity Range: 25 to 85%, relative humidity.Insulation Resistance: More than 500 MΩ at

500 V DC.Dielectric Strength: 1,500 V AC for one minute.

Quick and easy setting

279301/279303Decade Resistance Boxes

279301• High accuracy and stability• High reproducibility• 1 mΩ resolution

279303• Up to 100 MΩ in 100 Ω step• Low voltage coefficient• Shock- and vibration-proof construction

279301 Specifications

Resistance Range: 0.100 to 1,111.210 Ω (Mini-mum resistance is 0.100 Ω).

Dial Composition: 0.001 × 10 + 0.01 Ω × 10 + 0.1 Ω × 11 + 1 Ω × 10 + 10 Ω × 10 + 100 Ω × 10

Resolution: 0.001 ΩAccuracy: ± (0.01% + 2 mΩ) at temperature

23 ± 2°C, humidity 45 to 75%, and 0.1 W power application

High-accuracy, DC variable resistor with 6 dials

2792A SeriesStandard Resistors

• Traced to the national standard for high accuracy; test (calibrated) accuracy of ±5 ppm

• Resistance temperature coefficient• A variety of models Eight models with nominal resistance

values ranging between 0.001 Ω and 10 kΩ• Precision temperature control equipment,

such as an oil bath, not needed for calibration due to marked improvement in resistance temperature coefficient

• Included document: Test certificate

2792A series Specifications

Metal foil resistors

Operating temperature and humidity ranges: 0 to 50°C / 20 to 80% RHMaximum allowable power: 3 WTest (calibrated) accuracy: ±5 ppmPower characteristics: ±100 ppm/WInsulation resistance: More than 1000 MΩ at 500 V DCWithstand voltage: 1.5 kV for one minute be-

tween measurement terminal and casingTerminal construction: 4 terminalsExternal dimensions: Approximately ϕ 104 ×

150 mm (current terminal width: approxi-mately 174 mm)

Weight: Approximately 1.2 kgAccessories: User'S Manual, One Test Cer-

tificate

279303 Specifications

Resistance Range: 0 to 111. 1110 MΩ.Dial Composition: 100 Ω × 10 + 1 kΩ × 10 +

10 kΩ × 10 + 100 kΩ × 10 + 1 MΩ × 10 + 10 MΩ × 10.

Accuracy: 100 Ω, 1 kΩ, 10 kΩ and 100 kΩ steps ... ± (0.05% + 0.05 Ω)

1 MΩ and 10 MΩ steps ... ±0.2% (At temperature 23 ± 2°C, humidity below

75%, including residual resistance of ap-prox. 0.05 Ω).

Model Nominal value Accuracy 23°C±2°C

2792A01 0.001 Ω ±100 ppm

2792A02 0.01 Ω ±75 ppm

2792A03 0.1 Ω ±50 ppm

2792A04 1 Ω ±30 ppm

2792A05 10 Ω ±30 ppm

2792A06 100 Ω ±30 ppm

2792A07 1 kΩ ±30 ppm

2792A08 10 kΩ ±30 ppm

Met

ers

Pro

duct

s

81

Meters Products

Portable Instruments

2011 to 2053Portable Instruments

• Taut-band suspension system eliminates friction and provides strong resistance to shock impact.

• Stable performance for long term use.• Products have been widely used over many years as an industry standard at various

customers such as industries, power plants, research laboratories and schools, etc.

Line-up

DC Ammeters and Voltmeters 2011, 2012AC Ammeters and Voltmeters 2013, 2014Audio-frequency AC Voltmeters 2017Frequency Meters 2038Power Factor Meters 2039Wattmeters 2041, 2042Miniature DC Ammeters and Voltmeters 2051Miniature AC Ammeters and Voltmeters 2052, 2053

201314 205206

Recorders and Data Loggers

82

Model GP10 GP20-1 GP20-2 GM10-1 GM10-2

Mounting Desktop Desktop, DIN rail, vertical panel mount (screws)

Display (TFT color LCD) 5.7" (640 × 480 dots)

12.1" (800 × 600 dots)

Touch screen 4-wire resistive touch screen, 2-point touch detection

No. of connectable modules

3 10 10 (Up to 8 when GX90XA-10-T1 is mounted)

Max. (with expansion units) 10 10 45 10 42

No. of connectable expansion (sub) units

6 6 6 6 6

Max. no. of I/O channels 100 100 500 100 500

No. of connectable WT communication units (/E2*)

8 16 16 16 16

No. of communication channels (/MC*)

50 300 500 300 500

No. of channels allocatable to WT (/E2*)

50 300 300 300 300

No. of mathematical channels (MT*)

50 100 200 100 200

No. of recording channels 500 500 1000 500 1000

Internal memory (flash) 500 MB 500 MB 1.2 GB 500 MB 1.2 GB

Communication interface Ethernet, RS-232 (/C2*), RS-422/485 (/C3*), USB host (/UH*)

Ethernet, USB, RS-422/485 (/C3*), Bluetooth (/C8*)

Rated supply voltage

AC model 100 to 240 VAC 100 to 240 VAC

DC model 12 VDC 12 to 28 VDC

Dimensions (W × H × D) with modules mounted

144 × 168 × 248 (mm)

288 × 318 × 248 (mm) Max. 638 × 137.7 × 146 (mm)

Ambient temperature 0 to 50°C -20 to 60°C (-20 to 50°C for some configurations)

Measurement interval: 100/200/500 ms, 1/2/5 s

(Some intervals are not available depending on system configurations and modules.)

External storage media: 1 to 32 GB SD/SDHC memory card (a 1 GB card is included)

Format: FAT32 or FAT16

Data format: Binary or text

Ethernet: 10Base-T/100Base-TX (E-mail, FTP, Web, SNTP, etc.)

WT communication (/E2*): Supported models: WT1800, WT500, WT300

Supported communication: Ethernet

Communication interval: 500 ms, 1/2/5/10/15/20/30 s

USB host for GP (/UH*): Complies with USB 2.0

(USB memory; keyboard or mouse complying with HID Class Ver. 1.1)

USB communication for GM: Complies with USB 2.0 (recognized as a serial port by a PC)

Bluetooth for GM (/C8*): Bluetooth® Ver 2.1+EDR compliant, SPP (serial port profile),

Class 2 (communication range: approx. 10 m depending on the usage environment)*: Option code

Expansion (sub) unit specifications GX60 GM configuration

Construction Desktop, vertical panel mount (screws) Desktop, DIN rail, vertical panel mount (screws)

No. of connectable modules 6 6

Rated supply voltage

AC model 100 to 240 VAC 100 to 240 VAC

DC model 12 to 28 VDC

Dimensions (W × H × D) with modules mounted

412.5 × 164.7 × 147 (mm) Max. 438 × 137.7 × 146 (mm)

Ambient temperature 0 to 50°C -20 to 60°C (-20 to 50°C for some configurations)

Smart user interface for intuitive operation (GP series)

Review historical data easily Display digital values at any location

DragPast

Flick

Present

Zoom in/out horizontally and vertically

Pinch apart/Pinch

together

Monitoring and setting on a tablet (GM10)

Supports Bluetooth (option code/C8). There is no need to bring a PC to the

site; you can use a tablet for setting and monitoring.

Multi-unit configuration by connecting expansion units

Supports measurements at up to 450 ch (GP20) and 420 ch (GM10)

Up to 6 expansion (sub) unitsMain unit

LAN cable (CAT5 or later)

( The maximum distance

between units is 100 m.)

Acquire data from power measuring instruments

The GP recorder and the GM system can acquire data from power measuring

instruments (WT series power analyzers) without loss of fidelity and record

and display with their own data (option codes /E2 and /MC).

Ethernet

Power

Temperature

Model Suffix code Name Specification/Application Shortest cycle

GX90XA -10-U2N-4N Analog input module 10 ch, universal, SSR scanner type (RTD b-terminal common) DCV: ±20/60/200 mV, 1/2/6/20/50 V, etc.TC: R/S/B/K/E/J/T/N, etc.RTD: Pt100/JPt100, etc.DI: Voltage/contactCurrent (mA): 0 to 20/4 to 20 mA

100 ms

-10-L1N-4N 10 ch, low withstand voltage, DCV/TC/DI, SSR scanner type (isolated between channels) 500 ms

-10-T1N-4N 10 ch, DCV/TC/DI, electromagnetic relay scanner type (isolated between channels) 1 s

-10-C1N-4N 10 ch, current (mA), SSR scanner type (isolated between channels) 100 ms

GX90YA -04-C1N-4N Analog output module 4 ch, current (mA), (isolated between channels) Current (mA): 0 to 20/4 to 20 mA 100 ms

GX90XD -16-11N-4N Digital input module 16 ch (shared common) Input: Open collector or non-voltage contact Application: Remote control or operation recording/pulse (125 Hz when filter is ON)Output: Form C relay (SPDT) Application: Alarm output

100 ms

GX90YD -06-11N-3N Digital output module 6 ch 100 ms

GX90WD -0806-01N-3N Digital I/O module Input 8 ch (shared common), output 6 ch 100 ms

GX90XP -10-11N-4N Pulse input module 10 ch (shared common)DC Voltage, Open collector or non-voltage contact Application: Pulse (up to 20 kHz)

100 ms

GX90EX -02-TP1N-N I/O expansion module Each of GP main body, GM main unit, and expansion (sub) unit can mount one GX90EX. (One GX90EX is provided with a GX60.)

The “-4” in the suffix code represents the terminal form (-3: M3 screw terminal, -C: Clamp terminal)

Up to 10 modules of GX90YD and GX90WD can be mounted in a system. Each of the GP main body, GM main unit, and expansion (sub) unit can mount one GX90WD.

The /MT option (MATH) is required for GX/GP/GM main unit to perform pulse measurement/integration on GX90XD/GX90WD, or pulse integration on GX90XP.

For details, please contact Yokogawa Electric Corporation: Phone: (81)-422-52-7179 / E-mail: [email protected]

SMARTDAC+ Paperless Recorder GP Series, Data Acquisition System GM

GP10 GP20 GM

Specifications

I/O Modules and GX90EX (I/O expansion module)

A Next-generation Data Acquisition and Control System with Excellent Operability and Expandability

Catalog: Bulletin 04L51B01-01EN for GP series/Bulletin 04L55B01-01EN for GM

Recorders and Data Loggers

83

For details, please contact Yokogawa Electric Corporation: Phone: (81)-422-52-7179 / E-mail: [email protected] http://www.smartdacplus.com/

SMARTDAC+ GA10 Data Logging Software

Models, Suffix Codes, and Configurations Please contact us for the prices.

Model Suffix Code Description

GM10 Data Acquisition Module for SMARTDAC+ GM

Type -1 Standard (Max. measurement channels: 100)

-2 Large memory (Max. measurement channels: 500)

Area E General (temp. unit: Cel, degF)

— 0 Always 0

Optional Features /AH Aerospace heat treatment

/AS Advanced security function (Part 11)

/BT Multi-batch function

/C3 RS-422/485

/C8 Bluetooth

/E1 EtherNet/IP communication (PLC communication protocol)

/E2 WT communication /MC option must be specified.

/E3 OPC-UA server

/E4 SLMP communication (Mitsubishi PLC)

/LG Log scale

/MC Communication channel function

/MT Mathematical function (with report function)

Model Suffix Code Description

GM90PS Power Supply Module for SMARTDAC+ GM

Type -1 Always -1

Region N General

Supply Voltage 1 100 to 240 VAC

2 12 to 28 VDC Power Supply Connection: W only

Power Supply Connection D Power inlet with UL/CSA cable

F Power inlet with VDE cable

H Power inlet with GB cable

N Power inlet with NBR cable

Q Power inlet with BS cable

R Power inlet with AS cable

W Screw terminal (without power cable)

— 0 Always 0

Model Suffix Code Description

GM90MB -01N0 Module Base for SMARTDAC+ GM

Model Suffix Code Description

GX60 I/O base unit

Type -EX I/O expansion

Area N General

Power Supply 1 100 VAC, 240 VAC

Power Cord D Power cord UL/CSA standard

F Power cord VDE standard

R Power cord AS standard

Q Power cord BS standard

H Power cord GB standard

N Power cord NBR standard

W Screw terminal (power cord not included)

Model Suffix Code Description

GP10 Paperless recorder (portable type with a small display)

GP20 Paperless recorder (portable type with a large display)

Type -1 Standard (max. measurement channels: 100)

-2 Large memory (max. measurement channels: 500) (GP20 only)

Display Language E English, degF, DST (summer/winter time)

Power Supply 1 100 VAC, 240 VAC Power cord W cannot be specified

2 12 VDC (GP10 only) With power cord W only

Power Cord D Power cord UL/CSA standard

F Power cord VDE standard

R Power cord AS standard

Q Power cord BS standard

H Power cord GB standard

N Power cord NBR standard

W Screw terminal, power cord not included

Optional Features /AH Aerospace heat treatment

/AS Advanced security function (Part 11)

/BT Multi-batch function

/C2 RS-232Cannot be specified together.

/C3 RS-422/485

/CG Custom display

/D5 VGA output (only for GP20)

/E1 EtherNet/IP communication (PLC communication protocol)

/E2 WT communication /MC option must be specified.

/E3 OPC-UA server

/E4 SLMP communication (Mitsubishi PLC)

/FL Fail output (1 point)

/LG Log scale

/MC Communication channel function

/MT Mathematical function (with report function)

/UH USB interface (2 host ports)

Recorders can be shipped with specified I/O modules mounted (optional).

Monitors and records data from power meters, recorders, and data loggers

GA10 is a PC based software package that acquires data from

multiple devices – such as power meters (WT series), recorders,

and data loggers. Connected PCs can monitor real time and

historical data, which can be stored on a PC hard drive.

Max. connectable devices: 100

Max connectable clients: Unlimited (Connection with up to 32 units has been

verified.)

Max. recording tags (channels): Tags: 2000 ch

Mathematical tags (option code/MT): 200 ch

Scan interval: 100 ms at shortest (depending on the scan interval of

each instrument when using instrument time)

Multi-logging

Multi-logging function enables

acquisition of multiple data at

different timing. Data for each

testing instrument can be

processed separately.

Reporting/printing

Reports can be printed

automatically. The layout

can be customized. The

insertion of waveforms and

images, and the creation

of spreadsheets in PDF or

Excel format are supported (suffix code /RP).

Catalog: Bulletin 04L65B01-01EN

Expansion (sub) unit configuration

GP main body configuration GM main unit configuration

Recording Test equipment AStart Stop No.1

Stopped Test equipment BStart Stop No.2

Standby Test equipment CStart Stop No.3

Current time

Data logging softwareModel Suffix Code Description

GA10 Data Logging Software License

Number of Channels

-01 100 ch

-02 200 ch

-05 500 ch

-10 1000 ch

-20 2000 ch

Optional Features /RP Reporting/printing function

/MT Math function

/UA OPC-UA server function

* Channels can be added.

Additional monitoring PCs (clients)

ModelSuffix Code

Description

GA10CL Client License for GA10

Number of Licenses

-01 1 license

-05 5 licenses

-10 10 licenses

-50 50 licenses

Models and Suffix Codes Please contact us for the prices.

Specifications

Ethernet or Serial

Recorder Data Logger Power meter (WT series)

Aggregate data for monitoring!

GA10

Save the data all together!

Easy to read screen provides operator friendly monitoring

Acquired data can be stored on a PC.

Excel formatsupported

Hard

Drive

I/O module + GM90MB (Max. 6 modules)

GP10 (rear view) GP20 (rear view)

Main body alone:

Up to 3 I/O modules

With expansion units:

Up to 2 I/O modules +

GX90EX

Main body alone:

Up to 10 I/O modules

With expansion units:

Up to 9 I/O modules +

GX90EX

Main unit aloneGM10 +

GM90MB

I/O module + GM90MB (Max. 10 modules)

GM90PS

With sub units GM10 +

GM90MBGM90PS

GM90EX +

GM90MB

I/O module + GM90MB

(Max. 6 modules)

Up to 6 I/O modules

GX60

GX90EX + GM90MB GM90PS

84

Worldwide Business OperationsYokogawa Meters & Instruments Global Network

North & Central America

Yokogawa Corporation of America

Europe

Yokogawa Europe

South America

Yokogawa America do Sul

CIS

Yokogawa Electric CIS

Middle East & Africa

Yokogawa Middle East & AfricaASEAN

Yokogawa Engineering Asia

China

Yokogawa Shanhai Trading

Yokogawa Electric Korea

South Asia

Yokogawa India

Japan (Headquarters)

Yokogawa Meters &

Instruments Corporation

85

http://tmi.yokogawa.com/

http://www.yokogawa.com/ymi/

Search

GLOBALHOME / 0ur Businesses /

The following Web site offer a variety of information and services, such as document download, software download, user registration, e-mail news subscriptionand other.

Our Web site will help you find what you look for.

The following Web site offer a variety of information and services, such as document download, software download, user registration, e-mail news subscriptionand other.

Our Web site will help you find what you look for.

Digital OscilloscopesDigital Power AnalyzersOptical Measuring InstrumentsGenerators, Sources, Manometers etc.CalibratorClamp-on Power MeterDigital MultimeterClamp-on TesterInsulation TesterEarth TesterLeakage Current TesterIlluminance MeterThermometerPrecision Measuring InstrumentsMeters Products

Represented by:

2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750. JapanPhone: +81-422-52-6237 Facsimile: +81-422-52-6462 E-mail: [email protected]

YOKOGAWA METERS & INSTRUMENTS CORPORATION Global Sales Dept. http://tmi.yokogawa.com/

YMI-KS-MI-ME02

Subject to change without notice. [Ed: 05/b] Printed in Japan, 608(KP)All Rights Reserved, Copyright © 2011, Yokogawa Meters & Instruments Corporation

YOKOGAWA CORPORATION OF AMERICA2 Dart Road, Newnan, GA. 30265-1094 U.S.A.Phone: +1-770-253-7000 Facsimile: +1-770-254-0928

YOKOGAWA EUROPE B.V.Euroweg 2 3825 HD Amersfoort, THE NETHERLANDSPhone: +31-88-4641000 Facsimile: +31-88-4641111

YOKOGAWA SHANGHAI TRADING CO., LTD. 4F Tower D, Cartelo Crocodile Building, No.568 West Tianshan Road, Shanghai, CHINAPhone: +86-21-6239-6363 Facsimile: +86-21-6880-4987

YOKOGAWA ELECTRIC KOREA CO., LTD. C&M Sales Pangyo Office#901, Pangyo Innovalley F, 255, Pangyo-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-400, KoreaPhone: +82-2-2628-3810 Facsimile: +82-2-2628-3899

YOKOGAWA ENGINEERING ASIA PTE. LTD.5 Bedok South Road, Singapore 469270 SINGAPOREPhone: +65-6241-9933 Facsimile: +65-6241-2606

YOKOGAWA INDIA LTD. Plot No. 96. Electronic City Complex, Hosur Road, Bangalore 560100, INDIAPhone: +91-80-4158-6000 Facsimile: +91-80-2852-1441

YOKOGAWA ELECTRIC CIS LTD.Grokholskiy per. 13, Build. 2, 4th Floor, 129090, MoscowRUSSIAN FEDERATIONPhone: +7-495-737-7868 Facsimile: +7-495-737-7869

YOKOGAWA AMERICA DO SUL LTDA.Praca Acapulco, 31-Santo Amaro, Sao Paulo/SP, BRAZIL CEP-04675-190Phone: +55-11-5681-2400 Facsimile: +55-11-5681-4434

YOKOGAWA MIDDLE EAST & AFRICA B.S.C(c)P.O.BOX 10070, Manama, Building 577, Road 2516,Busaiteen 225, Muharraq, BAHRAINPhone: +973-17-358100 Facsimile: +973-17-336100

NOTICEBefore using the product, read the instruction manual carefully to ensure proper and safe operation.

nbn Elektronik Handelsgesellschaft m. b. H.Riesstraße 146, 8010 Graz | Tel. +43 316 40 28 05 | Fax +43 316 40 25 06www.nbn.at

Vertrieb für Österreich :