Upload
khangminh22
View
0
Download
0
Embed Size (px)
Citation preview
new
new
new
ScopeCorder
DL850E/DL850EV
High-Speed Data Acquisition Unit
SL1000
Mixed Signal
Oscilloscopes
DLM2000 Series
Mixed Signal Oscilloscopes
DLM4000 Series
Main Products Line up
Oscilloscopes Digital Power Analyzer
Generators, Sources, Manometers etc. Optical Measuring Instruments
Precision Power Analyzer
WT3000E
Power Analyzer
WT500
Digital Power Meters
WT300E Series
Precision Power Analyzer
WT1800
Precision Power Scope
PX8000
1G/10G Ethernet Tester
AQ1300 Series
DC Voltage /
Current Source
GS200
Optical Spectrum
Analyzer
AQ6370 Series
Optical Time Domain
Reflectmeter
AQ7280
Optical Loss Test Set
AQ1100
Multi Field Tester
OTDR
AQ1200 Series
Multi Application Test
System
AQ2200 Series
AQ2170
Series
Optical Wavelength Meter
AQ6150 Series
AQ2180
Series
AQ4280
Series
Handy size
Optical Power Meter
/ Light Source
AC Voltage
Current Standard
2558A
Precision DC
Calibrator
2553A
Precision DC
Calibrator
2560A
new
new
Calibrator
Digital Multimeter Insulation Tester
Illuminance Meter
Meters ProductsThermometer Clamp-on Power Meter
Clamp-on TesterEarth Tester
Precision Measuring Instruments
CA450
CW10CW500
732 Series
CL420
3213A Series
EY200510 Series
TM20 TX10 Series
279301
205206
CA700 CA150 CA71
TY700 Series TY500 Series
CL150/155
CL220
300
Series
MY40 MY10 Series 2406E Series
276910
201314 204102
73101
The Yokogawa website offers
not only product and technical
information but also campaign
information, user registration,
document download, free
software download, e-mail
news subscription, catalog
request, price inquiry, and lots
of other content.
Internet Website
http://tmi.yokogawa.com
CA310 CA320 CA330
DC Voltage/ Current Source (GS200) ...........36
Multi Channel Source Measure Unit (GS820) ...37
Source Measure Unit (GS610)......................38
GS Series Accessory Software (765670 Curve Tracer Software for the GS series) .............39
Precision DC Calibrator (2553A) ...................40
AC Voltage Current Standard (2558A) ..........41
Precision DC Calibrator (2560A) ...................42
Digital Multimeter (DM7560) .........................43
Digital Resistance Meter (7556) ...................44
Temperature Measuring Instrument (7563) ...44
Arbitrary/Function Generator (FG400 Series) ...45
Pressure Standard (MC100) .........................46
Manometers (MT210/MT210F/MT220/MT10) ...47
Optical Spectrum Analyzer (AQ6370 Series) ...48
Optical Spectrum Analyzer (AQ6370D) ........49
Optical Spectrum Analyzer (AQ6375B/AQ6376 ) ..................................50
Optical Spectrum Analyzer (AQ6373B) ........51
Optical Wavelength Meter (AQ6150 series) .....52
Multi Application Test System (AQ2200) .......53
Optical Time Domain Reflectmeter (AQ7280) ...54
MFT-OTDR (AQ1200) ...................................55
AQ2170 Optical Power Meter .......................56
AQ2180 Optical Power Meter .......................56
AQ4280 Optical Light Source .......................56
MFT-OLTS (AQ1100).....................................57
MFT-1/10GbE (AQ1300 Series) ....................58
Remote OTDR (AQ7277) ..............................59
ScopeCorder and High-Speed Data Acquisition Unit Selection Guide ....................................6
ScopeCorder (DL850E/DL850EV) ..................8
ScopeCorder Accessories ...................... 10, 11
High-Speed Data Acquisition Unit (SL1000) .... 12
High-Speed Data Acquisition Unit (SL1000 Acquisition Software) ................... 13
Digital and Mixed Signal Oscilloscopes Selection Guide .......................................... 14
Common Features of DL/DLM Series ........... 15
Mixed Signal Oscilloscope (DLM2000 Series) ................................ 16, 17
Mixed Signal Oscilloscopes (DLM4000) .... 18, 19
Waveform Measuring (Oscilloscopes Accessories) ......................20
Oscilloscope Application Software (Xviewer/MATLAB tool kit) ..........................21
Digital Power Analyzers Selection Guide ......22
Power Analyzer (WT500) ..............................23
Precision Power Analyzer (WT3000E) ....24, 25
High Performance Power Analyzer (WT1800) .............................................26, 27
Digital Power Meters (WT300E) .............28, 29
Precision Power Scope (PX8000) ...........30, 31
AC/DC Current Sensor (CT60/CT200/CT1000) ...............................32
Current Probe (751552) ................................32
Current Sensor Unit (751522 / 751524) ........32
WT Series Accessory Software (760122 and Power Consumption Measurement Software) ...........33
WT Series Accessory Software (761922 IEC regulation software) ...............34
Digital Power Analyzers Accessories List (Accessories List) .......................................35
[Generators, Sources, Manometers etc.] P. 36 ~ P. 47
[Optical Measuring Instruments] P. 48 ~ P. 59
[Oscilloscopes] P. 6 ~ P. 21
[Digital Power Analyzers] P. 22 ~ P. 35
Contents
Osc
illos
cope
sD
igita
l Pow
erA
naly
zers
Gen
erat
ors,
Sou
rces
,M
anom
eter
s et
c.
Optic
al M
easu
ring
Inst
rum
ents
Cal
ibra
tor
Cla
mp-
onP
ower
Met
erD
igita
l Mul
timet
erC
lam
p-on
Tes
ter
Insu
latio
n Tes
ter
Ther
mom
eter
Eart
h Tes
ter,
Oth
er P
rodu
cts
Pre
cisi
onM
easu
ring
Inst
rum
ents
Met
ers
Pro
duct
s
[Calibrator]CA700, CA150, CA51/CA71, CA310, CA320, CA330, CA310, CA320, CA330, CA450, CW500
P. 60 ~ P. 65
[Clamp-on Power Meter]CW10
P. 66
[Digital Multimeter]TY700 Series, TY500 Series, 732 Series, 73101, 96095
P. 68 ~ P. 71
[Clamp-on Tester]CL100 Series, CL200 Series, 30031A/30032A, CL300 Series, CL400 Series
P. 72 ~ P. 73
[Insulation Tester]MY40, 2406E Series, MY10 Series, 3213A Series
P. 74 ~ P. 77
[Earth Tester, Other Products]EY200, 322610, 510 Series
P. 78
[Thermometer]TM20, TX10 Series
P. 79
[Precision Measuring Instruments]2792A Series, 278610/278620, 2769, 279301/279303, 2755
P. 80
[Meters Products]Portable Instruments 2011 to 2053
P. 81
Products with this mark conform to the EMC standards (regulations
on electromagnetic interference) of European Community.
6
Osc
illos
cope
s
Oscilloscopes
They can be used to capture single-shot or infrequently recurring signals.
They can also execute computations on repetitive waveforms, and automatically extract waveform parameters.
Model
Item
DL850E/DL850EV
…P8
High-Speed Data Acquisition Unit SL1000
…P12
Features • Powerful mobile data acquisition recorders• Measure & analyze dynamic behavior of electromechanical systems• Flexible modular inputs for voltage, current, sensors, CAN/LIN bus and SENT.• Trend & Trigger on electrical power calculations (optional)
• Fast Acquisition, Transfer, and Storage• High-Performance Data Acquisition Unit• Easy to use Easy to use Standard Acquisition Software• Max 128 ch Synchronized (16 ch x 8 units) Data files recorded my multiple units, in synchronized mode, are all linked together by a common LINK file, thereby facilitating batch processing.
Max. sampling rate 100 MS/s (*2) 100 MS/s (*2)
Bandwidth 20 MHz (*2) 20 MHz (*2)
Number of analog input channels 128 ch max (when using eight 720220 modules) 16 ch max (when using any 2 ch input module.)
Logic input 128 bits max (when using eight 720230 modules) —
Max. vertical sensitivity (1:1) 100 μV/div (*2) 100 μV/div (*2)
Vertial axis resolution 16 bit (*2) 16 bit (*2)
Max. sweep sensitivity 100 ns/div (*2) 15 ns/div (Zoom display)
Max. record length St’d 250 Mpts (MW) max / 10 Mpts (MW) (16 ch) 50 MW/ch (Single Trigger Mode)
Optional 2 Gpts (GW) max / 100 Mpts (MW) (16 ch) —
Internal media drive St’d SD memory card slot —
Internal HDD Optional Internal 500 GB or external HDD (selectable) Internal 500 GB
Interface St’d USB2.0/ Ethernet (1000BASE-T) USB2.0
Optional GPIB Ethernet (1000BASE-T)
Internal printer 112 mm width (optional) —
Others Optional • 19 types of plug-in modules• IRIG interface• GPS interface• User-defined math function
• Real time math function• Probe power (4-output)• Power math function• DC 12V Power drive (DL850EV only)
• 12 types of plug-in modules• Probe power (4-output)• Without Xviewer• With the Xviewer Math Edition (1 license) (701992-GP01)
Display (TFT LCD) 10.4-inch color XGA (PC-based Acquisition Software)
External dimensions W × H × D (mm) 355 × 259 × 180 319 × 154 × 350
Weight (kg) Approx. 6.5 (*3) Approx. 6.0 (*3)
*1: See each product catalog for more detaled specifications *2: Depends on input module *3: Plug-in modules are not included
Waveform Measuring ScopeCorder and High-Speed Data Acquisition Unit Selection Guide (*1)
7
Osc
illos
cope
s
Oscilloscopes
Compatibility of the plug-in modules with the main units.
Plug-in Module Main Unit
Model Name DL850E DL850EV SL1000
701250 High-speed 10 MS/s 12-Bit Isolation Module available available available
701251 High-speed 1 MS/s 16-Bit Isolation Module available available available
701255 High-speed 10 MS/s 12-Bit non-Isolation Module available available available
701261 Universal Module available available available
701262 Universal Module (with Anti-Aliasing Filter) available available available
701265 Temperature/high-precision voltage Module available available available
701267 High-voltage 100 kS/s 16-Bit Isolation Module (with RMS) available available available
701270 Strain Module (NDIS) available available available
701271 Strain Module (DSUB, Shunt-CAL) available available available
701275 Acceleration/Voltage Module (with Anti-Aliasing Filter) available available available
701281 Frequency Module available available available
720211 High-speed 100 MS/s 12-Bit Isolation Module available available available
720220 16 CH Voltage Input Module available available NA
720221 16 CH Temperature/Voltage Input Module available available NA
720230 Logic Input Module available available NA
720240 CAN Bus Monitor Module NA available NA
720241 CAN & LIN Bus Monitor Module NA available NA
720243 SENT Monitor Module NA available NA
720254 4 CH 1 MS/s 16-Bit Isolation Module available available NA
* Probes are not included with any modules.
* Up to four CAN Bus Monitor Modules (720240), CAN & LIN Bus Monitor Modules (720241) or SENT Monitor Module (720243) in total can be used on a single
main unit. For the CAN Bus Monitor Modules (720240) and CAN & LIN Bus Monitor Modules (720241), up to two in total can be used on a single main unit.
These modules are available for the DL850EV only.
* The use of a 720221 module always requires the External Scanner Box (model 701953).
InputModel
No.Sample rate Resolution Bandwidth
Number ofchannels
IsolationMaximum
input voltage(DC+ACpeak)
DC accuracy Note
AnalogVoltage
720211*9 100 MS/s 12-Bit 20 MHz 2 Isolated1000 V*2 200 V*3
±0.5% High speed · High voltage · Isolated
701250*5 10 MS/s 12-Bit 3 MHz 2 Isolated600 V*2 200 V*3
±0.5% high noise immunity
701251 1 MS/s 16-Bit 300 kHz 2 Isolated600 V*2 140 V*3
±0.25%High sensitivity range (1 mV/div), low noise (±100 μVtyp.), and high noise immunity
720254 1 MS/s 16-Bit 300 kHz 4 Isolated600 V*2 200 V*3
±0.25%4 CH BNC input low noise, high noise immunity
701255*5 10 MS/s 12-Bit 3 MHz 2 Non-Isolated600 V*4 200 V*3
±0.5% non-isolation version of model 701250
701267 100 kS/s 16-Bit 40 kHz 2 Isolated 850 V*10 ±0.25% with RMS, and high noise immunity
720220 200 kS/s 16-Bit 5 kHz 16Isolated
(GND-terminal)non-isolated (CH-CH)
42 V*3 ±0.3% 16 CH voltage measurement (Scan-type)
Analog Voltage
& Tempera-
ture
701261100 kS/s (Voltage),
500 S/s (Temperature)16-Bit (Voltage),
0.1°C (Temperature)40 kHz (Voltage),
100 Hz (Temperature)2 Isolated 42 V
±0.25% (Voltage)
thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel)
701262100 kS/s (Voltage),
500 S/s (Temperature)16-Bit (Voltage),
0.1°C (Temperature)40 kHz (Voltage),
100 Hz (Temperature)2 Isolated 42 V
±0.25% (Voltage)
thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), with AAF
701265500 S/s (Voltage),
500 S/s (Temperature)16-Bit (Voltage),
0.1°C (Temperature)100 Hz 2 Isolated 42 V
±0.08 (Voltage)
thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), high sensitivity range (0.1 mV/div), and low noise (±4 μVtyp.)
720221*8 10 S/s 16-Bit 600 Hz 16 Isolated 42 V±0.15%
(Voltage)
16-CH voltage or temperature measure-ment (scan method)Thermocouple (K, E, J, T, L, U, N, R, S, B, W, Au-Fe-chromel)
Strain
701270 100 kS/s 16-Bit 20 kHz 2 Isolated 10 V ±0.5% (Strain)Supports strain NDIS, 2, 5, 10 V built-in bridge power supply
701271 100 kS/s 16-Bit 20 kHz 2 Isolated 10 V ±0.5% (Strain)Supports strain DSUB, 2, 5, 10 V built-in bridge power supply, and shunt CAL
Analog Voltage,
Acceleration701275 100 kS/s 16-Bit 40 kHz 2 Isolated 42 V
±0.25% (Voltage)±0.5%
(Acceleration)
built-in anti-aliasing filter, Supports built-in amp type acceleration sensors (4 mA/22 V)
Frequency 701281 1 MS/s 16-Bit resolution 625 ps 2 Isolated420 V*2
42 V*3
±0.1% (Frequency)
Measurement frequency of 0.01 Hz to 500 kHz, Measured parameters (frequency, rpm, period, duty, power supply frequency, distance, speed)
Logic 720230 10 MS/s — —8-bit × 2
portsnon-isolated
depend on logic probe
used.—
(8-bit/port) × 2, compatible with four-type of logic probe (sold separately)
CAN 720240 100 kS/s — —(60signals × 2)
portIsolated 10 V —
CAN Data of max. 32-bit allowableIt is available for DL850EV only. Max. two (2) modules can be installed in a main unit.*6 *7
CAN, LIN 720241 100 kS/s — —(60signals × 2)
portIsolated
10 V (CAN port)18 V (LIN port)
—CAN port × 1, LIN port × 1Available for DL850EV only, up to 2 modules*6 *7
SENT 720243 100 kS/s — —11 data × 2
portsIsolated 42 V —
Supported protocol: SAE J2716. It is available for DL850EV only. Max. four (4) modules can be installed in a main unit.*6 *7
*1: Probes are not included with any modules. *2: In combination with 700929, 702902 or 701947 probe. *3: Direct input *4: In combination with 10:1 probe model 701940
*5: Some of the models 701250/701255 shipped on or before July, 2007 may require factory rework. *6: Any other modules can be installed in the remaining slots.
*7: Up to four CAN Bus Monitor Modules (720240), CAN & LIN Bus Monitor Modules (720241) or SENT Monitor Module (720243) in total can be used on a single main unit. For the CAN Bus Monitor Modules (720240) and CAN & LIN Bus
Monitor Modules (720241), up to two in total can be used on a single main unit. *8: The 16-CH Scanner Box (701953) is required for measurement.
*9: Class 1 Laser Product, IEC60825-1:2007 *10: In combination with 758933 and 701954.
Plug-in Module Selection Guide*1
8
Osc
illos
cope
s
Oscilloscopes
A ScopeCorder is a powerful portable data acquisition
recorder that can capture and analyze both
transient events and trends up to 200 days. Using
flexible modular inputs it combines the measurements
of electrical and physical (sensor) signals, such as from
CAN, LIN, SENT and is also able to trigger on electrical
power related calculations in real-time.
Flexible Inputs with Built-in Signal ConditioningChoose from up to 19 input modules and gain a thorough insight into any
application by synchronizing the measurement of multiple parameters.
• Voltage and Current
• Sensor Outputs
• Temperature, Vibration
/Acceleration, Strain,
Frequency
• Logic Signals & CAN / LIN
and SENT
Large (2 GPoint) memory offers long duration measure-
ment and two instantaneous zoom locations
– 2 GPoint memory (/M2 option) –Comes standard with 250 MPoints of memory, expandable with 1 or 2 GPoint
options.
Large capacity memory does not only simply provide longer durations of
measurement, but also higher sampling rate at the same measurement time
or multi-channel at the same sampling rate.
Zoom to 2 locations
instantaneously
Zoom to 2 locations
instantaneously
Main screen:
20 days of recording
(2 days/div)
Zoom screen:
1 hour (12 min/div)
&
1 second (100 ms/div)
Up to 2 million times!
Instantly zooms 1
second (100 ms/div) even
when the main screen is
displaying 20 days of
recording (2 days/div)
Long memory does not guarantee
better efficiency if the memory
handling and display engine is slow.
Our faster than ever GIGAZoom 2
Engine instantaneously zooms into
two locations.
Long duration, continuous saving of waveforms
– Hard disk recording (/HD0, /HD1 option) –Measured data can be streamed directly to a built-in 500 GB hard disk (/HD1
option)*1 or through the external HDD interface (/HD0 option)*1. With long
periods of evaluation testing, measurements can be
performed at 100 kS/s on 16 channels simultaneously for 10 hours*2.
*1 The /HD0 and /HD1 options cannot be specified together.*2 It depends on the external hard disk connected when using the /HD0 option.
100 kS/sec
with 16 ch
simultaneously
Powerful data acquisition enables the research of dynamic behavior within your application
DL850EV
DL850E
Max. sampling rate 100 MS/s (720211)(*1)
Frequency bandwidth 20 MHz (720211)(*1)
Number of channels Max. 128 ch,
Number of slots for the plug-in module: 8
Logic input Max. 128 bits
(When using eight 720230 modules)
A/D conversion resolution 16 or 12 bits (1*)
DC accuracy ±(0.5% of 10 div)
(701250 and 701255)(*1)
Time axis setting 100 ns/div to 20-day/div
Time axis accuracy ±0.005%
Max. record length Standard 10 Mpts (MW)/ch, total 250 Mpts
(MW) (with /M2 option)
100 Mpts (MW)/ch, total 2 Gpts (GW)
Channel-to-channel Definable math waveforms 8
calculation function
Automatic measurement Maximum number of measured parameters 32
of waveform parameters
Cycle statistical/historic process Maximum number of cycles 64,000
Maximum number of parameters 64,000
Internal media drive SD memory card slot (standard)
500 GB internal hard drive (option)
External hard drive can be connected (option)
Communication interface USB 2.0 (standard)/1000BASE-T Ethernet (standard)
GP-IB (option)
Built-in printer(option) 112-mm width, A6 thermal printer
Other options IRIG interface
GPS interface
User defined computation
Real time math computation
Power math computation
Four probe power outputs
DC 12 V power drive (DL850EV only)
Display 10.4-inch TFT color LCD monitor
Display resolution 1024 × 768 pixels (XGA)
External dimensions 355 (W) × 259 (H) × 180 (D) mm
(excluding handle and protrusions)
Weight Approx. 6.5 kg to 9 kg (varies depending on
the types and the number of modules used)
(*1): Varies depending on the module.
ScopeCorder DL850E/DL850EV
Overview
Basic Specifications
9
Osc
illos
cope
s
Oscilloscopes
Continuous data recording for durability test and/or
surveillance testIntuitive, user-friendly acquisition software comes standard. Continuous
data recording into a PC Hard Disk Drive(HDD) can be performed by “free-
run mode” with no restriction of recording time and file size. The Wizard
automatically recognizes any connected DL850E and its’ plug-in modules.
Just click the Start button to start measuring right away--no complicated
settings to enter.
DL850E ACQ Software
Ethernet or USB
DL850E (front-end)
PC-Internal
HDD
Time synchronization for accurate measurements
– GPS interface (/C30 option) –A GPS antenna can be directly connected to the DL850E side panel. The
DL850E time clock and the sampling clock can be adjusted accordingly.
GPS satellite
GPS antenna
Note: This option can be provided only for a nation that is not prohibited by the Radio Law.
Trend waveform monitor for power and harmonic param-
eters in real time – /G5 option –Max. 126-type power parameter can be calculated. The calculation
results of these parameters can be displayed in DL850E screen as trend
waveforms in real time. The raw signal waveforms along with calculated
parameters(waveforms) can be displayed as trend waveforms with maximum
data updating rate of 100 kS/s.
Trend waveforms of each orders of harmonics, bar-graphs and vector
displays can be displayed.
[ Power parameter trend display example ] [ Harmonic analysis example ]
Once the “Analysis” key is pressed
on the front panel, the dedicated set-
up menu will appear on the screen
which enables to setup easily.
For example, 6-input(3-voltage and 3-current) waveforms for 2-line, which are
total 12 raw signal waveforms, can be monitored simultaneously along with
max. 126-parameter/1-line (or 54-parameters/2- line) can be calculated.
Inverter Inverter/Motor Testing
3-Voltage and 3-Current
DL850E /G5
3-Voltage and 3-Current
Input
Convert AC to DC signals
Inverter section
Modulate DC signal and convert to any AC signals
Drive circuitConverter section
Motor Torque/rotation sensor
Load
Model Number and Suffix Codes
Models and Suffix Codes
Model Suffix Codes Description
DL850E DL850E main unit, 250 MPts(W) memory*1
DL850EV DL850EV main unit, 250 MPts(W) memory*1
Power Cord
-D UL and CSA standard
-F VDE standard
-R AS standard
-Q BS standard
-H GB standard
-N NBR standard
Languages
-HE English menu and panel
-HJ Japanese menu and panel
-HC Chinese menu and panel
-HK Korean menu and panel
-HG German menu and panel
-HF French menu and panel
-HL Italian menu and panel
-HS Spanish menu and panel
Options
/B5 Built-in printer (112 mm)*5
/DC DC12 V power (10-18 V DC) (can be specified for DL850EV only)*5
/M1 Memory expansion to 1 GPts(W)*2
/M2 Memory expansion to 2 GPts(W)*2
/HD0 External HDD interface*3
/HD1 Internal HDD (500 GB)*3
/C1 GP-IB interface*4
/C20 IRIG and GP-IB interface*4
/C30 GPS interface*4, *7
/G2 User-defined math function
/G3 Real time math function*6
/G5 Power math function (with including Real time math function)*6
/P4 Four probe power outputs
*1: The main unit is not supplied with a plug-in module.
*2, *3, *4, *5, and *6: When selecting these, specify one of them.
*7: The /C30 option can be provided only for a nation that is not prohibited by the Radio Law.
[Example of comparison and verification of a measured signal
and CAN bus signal]
ECU Module Sensor 1 Sensor 2
Physical signal input (analog voltage, command pulse)
1 frame output (CAN only)(Data or remote frame)
CAN bus
Measurement by a module other than the CAN Bus Monitor Module
I/O in CAN Bus Monitor Module
Data frame input
Support for both AC and DC power (/DC option, DL850EV only)
Low power consumption of 60 - 120 VA (typ.)
Low noise compared to using an external inverter
12 V DC (10 – 18 V)
• Can be driven by external DC power
such as the vehicle’s battery
100 V AC (100 – 120 V)
200 V AC (200 – 240 V)
• Can also be driven by AC power.
Note: There is a certain restriction when using the 720240, 720241 and/or 720243 modules together with the /G5 option. Please contact our sales representative.
The ScopeCorder Vehicle Edition is designed for engineers working in the automotive and railway industry.
A common measurement challenge is to combine measurements of electrical signals, physical
performance parameters indicated by sensors, together with CAN bus, LIN bus or SENT data transmitted by
the powertrain management system. A ScopeCorder Vehicle Edition addresses this challenge by combining
the measurement of all signals to provide thorough insight into the dynamic behavior of the
electromechanical system. The result is a considerable time saving compared to other approaches such as
analysis on PC or other software.
VEHICLE EDITION
Enhanced capabilities for vehicle design and development such as CAN, LIN buses and SENT monitoringEnhanced capabilities for vehicle design and development such as CAN, LIN buses and SENT monitoring
10
Osc
illos
cope
s
Oscilloscopes
Waveform Measuring ScopeCorder Accessories
Product Model No. Description*1
Differential Probe 700925DC to 15 MHz, 1/10-1/100 selector switch, max. allowable differential voltage ±500 V (DC + ACpeak)
Differential Probe 700924DC to 100 MHz, 1/100-1/1000 selector switch, max. allowable differential voltage ±1400 V (DC + ACpeak) or 1000 Vrms (1/1000 range)
Current Probe 701917 5 Arms, DC to 50 MHz, High-sensitivity
Current Probe 701933 30 Arms, DC to 50 MHz, supports probe power
Current Probe 701930 150 Arms, DC to 10 MHz, supports probe power
Current Probe 701931 500 Arms, DC to 2 MHz, supports probe power
Current Probe 701932 30 Arms, DC to 100 MHz, supports probe power
Probe Power Supply 701934 Supply (4 outputs), large current output, external probe power
10:1 Probe (for Isolated BNC Input) 700929 1000 Vpk-CAT II
10:1 Probe (wide temperature range, for isolated BNC input)
702902 -40 to +85°C, DC to 60 MHz, 1000 Vpk-CAT II
1:1 Safety BNC Adapter Lead(in combination with followings)
701901 1000 Vrms-CAT II
Safety mini-clip (Hook type) B9852MM 1000 Vrms-CAT III, black
Safety mini-clip (Hook type) B9852MN 1000 Vrms-CAT III, red
Large Alligator-Clips (Dolphin type) 701954 1000 Vrms-CAT II, 1 set each of red and black
Passive Probe (10:1)*2 701940 Non-isolated 600 Vpk
1:1 BNC-Alligator Cable 366926 Non-isolated 42 V or less, 1 m
*1: Actual allowable voltage is the lower of the voltages specified for the main unit, probe and cable.
*2: 42 V is safe when using the 701940 with an isolated type BNC input.
11
Osc
illos
cope
s
Oscilloscopes
Accessories Combinations
Plug on clip701948
Isolation probe700929
/P4, Probe Power 4-output (option)
Probe Power 4-output701934
Frequency Module701281
High-speed 100 MS/s12-Bit Isolation Module720211
High-speed 1 MS/s 16-bit Isolation Module701251
4CH 1 MS/s 16-bit Isolation Module720254
High-speed 10 MS/s 12-bit Isolation Module701250
High-Voltage 100 kS/s16-Bit Isolation Module701267
Logic inputModule720230
16 CH Temp./Voltage Input Module720221
Logic Probe (TTL level/Contact Input)1 m: 7029113 m: 702912
Isolated Logic Probe700987
Scanner Box701953(Provided with a connecting cable)Note: This unit is always required for measurement.
High-speed Logic Probe700986
1:1 Banana-alligator Cable366961
Warning:Connect the probe earth cable to ground (grounding potential) when using these differential probes with isolation modules.
Passive Probe for SL1400/DL750701940
BNC cable1 m: 3669242 m: 366925
BNC-alligator cable366926
±500 V, 15 MHzDifferential Probe700925
±1400 V, 100 MHzDifferential Probe700924
7000 Vpk, 50 MHzDifferential Probe701926
Universal Module701261
Universal Module (with AAF)701262
Temperature/High-precision Voltage Module701265
Shunt Resister for 4-20 mA Measurement250 Ω ± 0.1% : 438920100 Ω ± 0.1% : 438921 10 Ω ± 0.1% : 438922
High-speed 10 MS/s 12-bit Non-isolation Module701255
Acceleration/Voltage Module (with AAF)701275
Strain Module (NDIS)701270
Strain Module (DSUB Shunt-CAL)701271
Bridge Head (NDIS)120 Ω: 701955350 Ω: 701956
Bridge Head (DSUB, Shunt-Cal)120 Ω: 701957350 Ω: 701958
Long Test Clips 701906
Alligator Adapters758929
Fork Terminal Adapters758921
Large Alligator Clips (Dolphin Type)701954
Safety mini clips(Hook Type)B9852MM/B9852MN
Alligator Adapters 758922
1:1 Safety BNC Adapter Lead701901
Isolation probe701947
Current Probe 30 Arms DC-50 MHz701933
Current Probe 150 Arms DC-10 MHz701930
Safety BNC Cable 1 m : 7019023 m : 701903
Current Probe 500 Arms DC-2 MHz701931
Current Probe5 Arms DC-50 MHz701917
Measurement Lead Set758933
10:1 Passive Probe702902
4 mm Conversion AdapterB8099NL/B8099NM
12
Osc
illos
cope
s
Oscilloscopes
High-Speed Data Acquisition Unit SL1000
Unit 0Waveform
file
Unit 1Waveform
file
Unit 2Waveform
file
Unit 1-7Data link
file
Ethernet/USB
SYNCIN
SYNCOUT
Unit 7Waveform
file
Easy to use
– Easy to use Standard Acquisition Software
Max 128 ch Synchronized (16 ch x 8 units)
– Data files recorded by multiple units, in synchronized mode, are all linked
together by a common LINK file, thereby facilitating batch processing.
Using this LINK file, data from all units can be processed and analyzed, as
one, at the same time.
Plug & Play: Auto-recognition of units and modules Input type: Plug-in module (A/D converters built in to each unit)Maximum number of input channels: 16 (One unit operation) 128 (8 units synchronous operation)Maximum sample rate: 100 MS/s on all channelsMeasuring mode: Free Run and TriggeredClock source: Internal and externalMaximum record length (internal memory): In Free Run mode 1 module: 32 MW/ch 2 modules: 16 MW/ch 3 to 4 modules: 8 MW/ch 5 to 8 modules: 4 MW/ch In Single Trigger mode 1 module: 50 MW/ch 2 modules: 25 MW/ch 3 to 4 modules: 10 MW/ch 5 to 8 modules: 5 MW/chMeasuring groups: Up to 4 groups definable with independent sample ratesTrigger mode: Normal, Single, and Single(N)Trigger source: Input channel, External, LINE , TimeRecord conditions: For Free Run mode Immediate, abs. time, time divided, alarm, and external trigger For Trigger mode Each triggerInternal hard disk: 500 GB (with the /HD1 option)Maximum real-time hard disk recording speed: Internal hard disk 1.6 MS/s (= 200 kS/s × 8 ch = 100 kS/s × 16 ch)
Sampling rate
Number of Measuring Channels
2 ch 4 ch 8 ch 16 ch
100 MS/s 0.5 0.25 0.1 0.05
50 MS/s 1 0.5 0.2 0.1
10 MS/s 2.5 1.25 0.5 0.25
1 MS/s 25 12.5 5 2.5
500 kS/s 100 50 20 10
200 kS/s 250 125 50 25
1 kS/s 50000 25000 10000 5000
Fast Acquisition
– Up to 100 MS/s on all channels (10 ns sampling interval)
– Supports parallel testing: Perform measurements with up to four simulta-
neously independent sample rates
Fast Transfer and Storage
– Stream data to PC via high speed USB 2.0 or 1000BASE-T Gigabit Ether-
net
– Stream data to a PC hard disk or the SL1000's internal hard disk in real
time (at speeds of 1.6 MS/s = 100 kS/s × 16 ch)1
– Maximum 8 synchronized units
1: Speed depends on PC performance and measuring conditions.
Stand-Alone Recording
– Normally, SL1000 is controlled by PCs. However, SL1000 can record data
even without PCs (/HD1 option is required).
This stand-alone recording function is useful for the measurement in the
severe environment.
Basic Specifications
Model Number and Suffix Codes
Maximum measuring time (unit: sec) at Single triggered measurement
Features
Fast Acquisition, Transfer, and Storage
High-Performance Data Acquisition Unit
SL1000
Model Suffix Code Description
720120SL1000 High-Speed Data Acquisition Unit*1
Including Xviewer Standard Edition (1 license)(701992-SP01)
Power cord
-D UL and CSA standard
-F VDE standard
-R AS standard
-Q BS standard
-H GB standard (Complied with CCC)
Options
/HD1 Internal 500 GB HDD
/C10 Ethernet Interface
/P4 Probe power (4-output)
/XV0 Without Xviewer
/XV1 With the Xviewer Math Edition (1 license)(701992-GP01)
*1: Plug-in modules and PC not included with the SL1000.
Model Description
720211 High-speed 100 MS/s 12-Bit Isolation Module (2 ch)
701250 High-speed 10 MS/s 12-Bit Isolation Module (2 ch)
701251 High-speed 1 MS/s 16-Bit Isolation Module (2 ch)
701255 High-speed 10 MS/s 12-Bit non-Isolation Module (2 ch)
701267 High-voltage 100 kS/s 16-Bit Isolation Module (with RMS, 2 ch)
701261 Universal Module (2 ch)
701262 Universal Module (with Anti-Aliasing Fileter, 2 ch)
701265 Temparature / High-precision voltage Module (2 ch)
701275 Acceleration / Volatage Module (with Anti-Aliasing Filter 2 ch)
701270 Strain Module (NDIS, 2 ch)
701271 Strain Module (DSUB, Shunt-CAL, 2 ch)
701281 Frequency Module
Product Model No. Description
Synchronized connection cable720901-01 For SL1000 (1 m)
720901-02 For SL1000 (3 m)
Rack mounting kit751541-E4 EIA standard
751541-J4 JIS standard
13
Osc
illos
cope
s
Oscilloscopes
High-Speed Data Acquisition Unit SL1000 Acquisition Software
Setup Wizard
Startmeasurement
Main Specifications of Acquisition Software
Accumulating Waveforms
Displaying X-Y Waveforms
Setting Marks
Setup Wizard Makes It Easy
The four screens of the Setup Wizard guide you easily through detailed settings
for configuring the system, measuring, saving, and displaying. You can save and
recall your settings at any time.
Plug and Play Auto-recognition of units and modulesMeasurement modes Free Run and TriggeredACQ modes Normal, envelope, and box averageClock sources Internal and externalMeasurement groups Up to 4 groups definable with independent sample ratesTrigger modes Normal, single, and single(N)Trigger sources CH1-CH16, LINE, Time, and ExternalOther trigger functions Combination trigger, hold-off, pretriggers, and trigger delaySave conditions Manual operation, or based on time, or alarmsOther save functions Manual save (file division), specify no. of saves, save all data
in memory, and save simultaneously to PC’s hard disk and SL1000’s internal hard disk (with /HD1 option)
Save format Binary data file (original, *.wdf)Waveform data Binary data file(s) can be converted to ASCIIconversion (Xviewer) (*.csv) or Excel (*.xls) formatMaximum speed for saving in real time PC hard disk 1.6 MS/s (= 100 kS/s × 16 channels)*1
Waveform monitor Trend display (displays measured waveforms of different sample rates simultaneously)*2, and instantaneous value displays (digital, bar graph, meter, and thermometer)
X-Y display X-axis channel settings, selection of main or zoomed waveform (in Triggered mode), and selection of the number of data points to draw (2 K, 10 K, 100 K)
Mark display (Free run mode) Setting of marks (up to 128 marks, each mark can display up to 16 characters), display color setting, mark editing, deletion of marks, mark list, collectively saving mark data with the same file name as the waveform data, and loading mark data into Xviewer.
Accumulation display Accumulates T-Y and X-Y waveformsSnapshot Waveform that is currently being displayed can be retained on
the screen as a snapshot waveform. Display color setting and snapshot waveform deletion
Display groups Up to 4 display groupsOther display functions History waveform, arbitrary axis divisions, and horizontal axis
scaling + specifiable units (external clock)Waveform analysis Cursor and parameter measurement*3
Offline waveform computation (with /XV1 option) Max. Number of displayed waveforms (CHs)
10 waveforms (Math1 to Math 10) Operations +, -, ×, /, trigonometry, differentiation/integration, FFT, and othersAlarms Channel (alarm display and alarm history analysis)*4, system
alarm, and alarm outputGO/NO-GO determination*3 Waveform parameter judgment and judgment outputSystem requirements OS Windows XP (SP2 or later) /Windows 7 (32 bit /64 bit) /
Windows 8 (32 bit /64 bit) CPU Core 2 Duo 2 GHz or better Memory 1 GB or more Hard disk 500 MB or more of free space (40 GB or more when using the
auto-save function) Communication interfaces USB 2.0/Ethernet 1000BASE-T (with /C10 option) Display XGA or better, Color: 65536 colors or better Other CD-ROM drive and mouse
*1: Typical values. Actual values depend on PC performance and measurement conditions.*2: When the measurement mode is Free Run, the trigger mode is Single(N), and the number of
measurements is Infinite, there may be a limit to the number of channels that can be trend-displayed during measurement.
*3: Triggered measurement*4: Free Run measurement
For details on 701992 Xviewer, see page 21.
Control Buttons––Just Like Your DVD Remote
Measurement and saving can be started and stopped using the same familiar
buttons found on a DVD remote control. Start using the instrument on the same
day you receive it, with absolutely no programming required.
You can enter comments in the Mark area when monitoring over long periods of
time (Free Run mode).
You can view both T-Y waveform display and X-Y waveform display. Using its fast
update feature, you can evaluate data quickly and easily.
Using the accumulation feature, you easily view unevenness of repetitive data.
Intuitive OperationEasy to Use
14
Osc
illos
cope
s
Oscilloscopes
The DLM series digital oscilloscopes
have high-speed sampling and a
wide range of bandwidths that
can be utilized for design and
development of electronic devices.
They can also execute computations
on repetitive waveforms and
automatically extract waveform
parameters.
The DLM series offers an extensive
selection of digital oscilloscopes
with large-capacity memories,
powerful triggering functions,
unique History Memory function
and built-in printers. It also can save
and load data to and from internal or
external media.
ModelItem
DLM2000 Series ...P16 DLM4000 Series ...P18
Features Compact & lightweight
Analog 4 ch/Analog 3 ch+Logic 8bits
Long memory
UART,I2C,SPI,CAN,CAN FD,LIN,FlexRay and SENT bus
analysis functions
Power supply analysis functions
Analog 8 ch+Logic 16bits/Analog 7 ch+Logic 24bits
Long memory
UART,I2C,SPI,CAN,CAN FD,LIN,FlexRay and SENT bus
analysis functions
Power supply analysis functions
Large display
Max. sampling rate 2.5 GS/s 2.5 GS/s
Bandwidth 500 MHz(*2) 500 MHz(*2)
Number of analog input channelsDLM2022,DLM2032,DLM2052:2
DLM2024,DLM2034,DLM2054:48
Logic input St’d DLM2024, DLM2034,
DLM2054: St’d 8 bits
8 bits
Optional 24 bits
Max. vertical sensitivity (1:1) 2 mV/div 2 mV/div
Vertial axis resolution 8 bits 8 bits
Max. sweep sensitivity 1 ns/div 1 ns/div
Max. record lengthSt’d 62.5 Mpoints 12.5 Mpoints
Optional 250 Mpoints 250 Mpoints
Internal storageSt’d Approx. 300 MB Approx. 1.8 GB
Optional Approx. 7.2 GB Approx. 7.2 GB
InterfaceSt’d USB USB/Ethernet
Optional Ethernet/GP-IB GP-IB
Built-in printer Optional 112 mm width 112 mm width
Others Optional I2C bus analysis
SPI bus analysis
CAN, CAN FD and LIN bus analysis
FlexRay bus analysis
SENT bus analysis
UART bus analysis
Probe Power
Power supply analysis functions
User-defined math functions
I2C bus analysis
SPI bus analysis
CAN, CAN FD and LIN bus analysis
FlexRay bus analysis
SENT bus analysis
UART bus analysis
Probe Power
Power Supply analysis functions
User-defined math functions
Display (TFT LCD) 8.4-inch color, XGA 12.1-inch color XGA
External dimensions
W × H × D (mm)226 × 293 × 193 426 × 266 × 178
Weight (kg) Approx. 4.2 Approx. 6.6
*1: See each product catalog for more detaled specifications.
*2: Depends on model
Waveform Measuring Digital and Mixed Signal Oscilloscopes Selection Guide
15
Osc
illos
cope
s
Oscilloscopes
This feature meets the need to measure as many signals
as possible simultaneously with one oscilloscope.
DLM2000/DLM4000 series
The DLM2000 (DLM4000) series usually functions as 4 (8)
channel analog, and is able to switch CH 4 (8) of analog input to
8-bit logic quickly whenever the need arises.
Common Features of DL/DLM Series
When the sample rate is increased with oscilloscopes
with less memory, the observation time may run out.
All of Yokogawa’s oscilloscope models are equipped
with large capacity memory. For example, the DLM2000/
DLM4000 offers long memory of up to 250 Mpoints for
measurement.
Even at a fast sample rate of 1.25 GS/s, waveforms for 0.2
seconds can be captured.
The history memory function that divides the long
memory can redisplay past waveforms that have
disappeared from the screen.
With the DLM2000/DLM4000 series, up to 50,000
previously captured waveforms can be saved in
memory.
Since a large amount of data is also processed at high
speed by dedicated hardware, the long memory can be
used comfortably without sacrificing response time.
To facilitate the use of a PC, various interfaces such
as USB, Ethernet, and GP-IB are available as standard
or an option.
In addition, various software is available to support
remote control, file transfer, and data processing
on a PC.
USB memory and peripheral devices, such as keyboard
and mouse, can be connected, and connecting to a PC
using a USB cable enables it to be used as the external
storage of the PC.
With a small built-in printer, measured waveforms can
be printed to paper immediately.
• A variety of triggers capture complex waveforms
• Real time digital filter with optimum noise reduction
• Zooms into two different points simultaneously
• Automated measurement of waveform parameters and
statistical processing function
• Frequency analysis by FFT computation
• Go/No-Go function and action on trigger function to
determine abnormal waveforms and save files.
• Analysis functions for specific applications, such as
serial bus analysis and power supply analysis
LogicAnalog
DLM4000 series
Up to 8 channels of analog signals can be measured.
ScopeCorder Series is available for customers that
require more channels for measurement (see page 6).
The DL850E supports up to 128 channel measurement.
Multichannel
Long Memory
Connection with a PC
Built-in Printer
A Variety of Triggers and Analysis Functions
USB memory USB keyboard
1000BASE-T/100BASE-TXcompliant adapters (hubs and routers)
Sends waveform, screen, and settings dataRemote control
Sends waveform, screen, and settings data
Remote control
Mail transmission (GO/NO-GO action)
USB (standard on rear panel)
Internal storage (/C9 option)
Ethernet(/C10 and /C11 options)
Waveform history
16
Osc
illos
cope
s
Oscilloscopes
Easy-to-Use, Portrait Body, Compact, and Large Screen Personal Mixed Signal Oscilloscope Offers Convenience with Logic Inputs
Easy-to-Use & Easy-to-See
Easy to use. Portrait body + large screen makes display easy to see.
We elevated the large (8.4-inch) LCD screen up into the line
of sight. Also, the portrait format saves space on the desk or
test bench. A compact personal oscilloscope designed for easy
viewing and ease of use.
Signal observation on 4 channels or more...
Flexible MSO Input
Four channels is not sufficient to view the functioning of digital
control circuits. The DLM2000 series converts 4 channels of
analog input to 8-bit logic, and functions as a 3 channel analog
+ 8-bit logic MSO (mixed signal oscilloscope).
You can replay waveforms later on, so you'll never miss
an abnormal waveform
History function
With the DLM2000 series, up to 50,000 previously captured
waveforms can be saved in the acquisition memory. With the
History function, you can display just one or all of the previously
captured waveforms (history waveforms) on screen. You can
also perform cursor measurement, computation, and other
operations on history waveforms. Using the History function, you
can analyze rarely-occurring abnormal signals.
DLM2000
Analog Signal input Input channels Analog input DLM20x2: CH1, CH2 DLM20x4: CH1 to CH4 (CH1 to CH3 when using logic input) Input coupling setting AC, DC, DC50 Ω, GND Input impedance Analog input 1 MΩ ±1.0%, approximately 20 pF 50 Ω ±1.0% (VSWR 1.4 or less, DC to 500 MHz) Voltage axis sensitivity 1 MΩ 2 mV/div to 10 V/div (steps of 1-2-5) setting range 50 Ω 2 mV/div to 500 mV/div (steps of 1-2-5) Max. input voltage 1 MΩ 150 Vrms (CAT I) 50 Ω Must not exceed 5 Vrms or 10 Vpeak Frequency characteristics (-3 dB attenuation when inputting a sinewave of amplitude ±3 div)*1*2
DLM202x DLM203x DLM205x 1 MΩ (when using passive probe) 100 mV to 100 V/div DC to 200 MHz DC to 350 MHz DC to 500 MHz 20 mV to 50 mV/div DC to 150 MHz DC to 300 MHz DC to 400 MHz 50 Ω 10 mV to 500 mV/div DC to 200 MHz DC to 350 MHz DC to 500 MHz 2 mV to 5 mV/div DC to 150 MHz DC to 300 MHz DC to 400 MHz Maximum sample rate Real time sampling mode Interleave OFF 1.25 GS/s Interleave ON 2.5 GS/s Repetitive sampling mode 125 GS/s Maximum record length 2 ch model Repeat/Single/Single Interleave: (/M1S) 6.25 M/25 M/62.5 MPoints 4 ch model Repeat/Single/Single Interleave: (/M1) 6.25 M/25 M/62.5 MPoints 4 ch model Repeat/Single/Single Interleave: (/M2) 12.5 M/62.5 M/125 MPoints 4 ch model Repeat/Single/Single Interleave: (/M3) 25 M/125 M/250 MPointsLogic Signal Input (4 ch model only)
Number of inputs 8 bit (excl. 4 ch input and logic input) Maximum toggle frequency*1 Model 701988: 100 MHz Model 701989: 250 MHz Compatible probes 701988, 701989 (8 bit input) (701980, 701981 can also be used) Display 8.4-inch TFT color liquid crystal display 1024 × 768 (XGA)Rated supply voltage 100 to 240 VAC Rated supply frequency 50 Hz/60 Hz Maximum power consumption 170 VA External dimensions 226 (W) × 293 (H) × 193 (D) mm (when
printer cover is closed, excluding protrusions)
Weight Approx.4.2 kg With no optionsOperating temperature range 5°C to 40°C
*1 Measured under standard operating conditions after a 30-minute warm-up followed by calibration. *2 Value in the case of repetitive phenomenon.
Mixed Signal Oscilloscope DLM2000 Series
Basic Specifications
Features
Waveform history
Abnormal signal
Vertical Postion and Scale Knob
Horizontal Postion and
Scale Knob
Trigger Control Keys and Level Knob
Dedicated Zoom Keys
Jog Shuttle and Rotary
Knob
Four-Direction Selector
Button
Select key moves the
cursor up/down/left/right
Logic input connector
17
Osc
illos
cope
s
Oscilloscopes
Model Suffix code Description
710105 Digital Oscilloscope DLM2022 2 ch, 200 MHz
710110*1 Mixed Signal Oscilloscope DLM2024 4 ch, 200 MHz
710115 Digital Oscilloscope DLM2032 2 ch, 350 MHz
710120*1 Mixed Signal Oscilloscope DLM2034 4 ch, 350 MHz
710125 Digital Oscilloscope DLM2052 2 ch, 500 MHz
710130*1 Mixed Signal Oscilloscope DLM2054 4 ch, 500 MHz
Power cord -D UL/CSA standard
-F VDE standard
-Q BS standard
-R AS standard
-H GB standard
-N NBR standard
Language -HE English Menu and Panel
-HC Chinese Menu and Panel
-HK Korean Menu and Panel
-HG German Menu and Panel
-HF French Menu and Panel
-HL Italian Menu and Panel
-HS Spanish Menu and Panel
Option /LN No switchable logic input (4 ch model only)
/B5 Built-in printer
/M1*2 (standard) Standard memory (4 ch model only) During continuous measurement: 6.25 Mpoints; Single mode: 25 Mpoints (when interleave mode ON: 62.5 Mpoints)
/M2*2 Memory expansion (4 ch model only) During continuous measurement: 12.5 Mpoints; Single mode:62.5 Mpoints (when interleave mode ON: 125 Mpoints)
/M3*2 Memory expansion (4 ch model only) During continuous measurement: 25 Mpoints; Single mode: 125 Mpoints (when interleave mode ON: 250 Mpoints)
/M1S (standard) Standard memory (2 ch model only) During continuous measurement: 6.25 Mpoints; Single mode: 25 Mpoints (when interleave mode ON: 62.5 Mpoints)
/P2*3 Probe power for 2 ch models
/P4*3 Probe power for 4 ch models
/C1*4 GP-IB Interface
/C10*4 Ethernet Interface
/C11*4 GP-IB + Ethernet Interface
/C9 Internal storage (7.2 GB)
/G2*5 User defined math (4 ch model only)
/G3*5 Power supply analysis function (4 ch model only)
/G4*5 Power supply analysis function (includes /G2) (4 ch model only)
/F1*6 UART trigger and analysis (4 ch model only)
/F2*6 I2C + SPI trigger and analysis (4 ch model only)
/F3*6 UART + I2C + SPI trigger and analysis (4 ch model only)
/F4*7 CAN + LIN trigger and analysis (4 ch model only)
/F5*7 FlexRay trigger and analysis (4 ch model only)
/F6*7 FlexRay+CAN+LIN trigger and analysis (4 ch model only)
/F7*7 CAN+CAN FD+LIN trigger and analysis (4 ch model only)
/F8*7 FlexRay+CAN+CAN FD+LIN trigger and analysis (4 ch model only)
/F9 SENT analysis (4 ch model only)
/EX22*8 Attach two 701946 probes (For 2 ch, 200 MHz models)
/EX24*8 Attach four 701946 probes (For 4 ch, 200 MHz models)
/EX52*9 Attach two 701946 probes (For 2 ch, 350/500 MHz models)
/EX54*9 Attach four 701946 probes (For 4 ch, 350/500 MHz models)
*1: Logic probes sold separately. Please order the model 701988/701989 accessory logic probes separately. *2: One of these must be selected.*3: Specify this option when using current probes or differential probes that don't support probe interface. *4: Only one of these may be selected at a time.*5: Only one of these may be selected at a time. *6: Only one of these may be selected at a time.*7: Only one of these may be selected at a time.*8: The 701938 probes are not included when this option is specified.*9: The 701939 probes are not included when this option is specified.
Additional Option License for DLM2000*Model Suffix code Description
709810 -G2 User defined math (4 ch model only)
-G3 Power supply analysis function (4 ch model only)
-G4 Power supply analysis function (includes G2) (4 ch model only)
-F1 UART trigger and analysis (4 ch model only)
-F2 I2C + SPI trigger and analysis (4 ch model only)
-F3 UART + I2C + SPI trigger and analysis (4 ch model only)
-F4 CAN + LIN trigger and analysis (4 ch model only)
-F5 FlexRay trigger and analysis (4 ch model only)
-F6 FlexRay + CAN + LIN trigger and analysis (4 ch model only)
-F7 CAN+CAN FD+LIN trigger and analysis (4 ch model only)
-F8 FlexRay+CAN+CAN FD+LIN trigger and analysis (4 ch model only)
-F9 SENT analysis (4 ch model only)
-X1 F4 -> F7/F6 -> F8 (add CAN FD)
*: Separately sold license product (customer-installable).
Analysis Functions
Models and Suffix Codes
Even complex waveforms can be captured
Variety of triggers combining analog and logic inputs
The DLM2000 series comes with a variety of triggers ranging
from an easy and simple Edge trigger through to sophisticated
Enhanced and B triggers. In particular, its ability to freely
combine analog and logic inputs is a great feature of this mixed
signal oscilloscope equipped with a hybrid channel.
FlexRay/UART/CAN/CAN FD/LIN/SENT/I2C/SPI
Serial analysis function options
A wide variety of trigger conditions can be set, such as ID/Data
trigger combinations and combinations of serial bus triggers with
normal edge triggers. Up to four busses with different types and
speeds can be analyzed simultaneously and decode display can
be shown in real time.
Switching loss, power measurement, joule integral, SOA
analysis, and harmonic current based on EN61000-3-2
Power supply analysis option
Utilizing the long memory capability, voltage and current
waveforms over long cycles can be input for computation of
switching loss (V(t) X i(t)). A wide variety of switching loss
analyses are supported, including turn on/off loss calculation,
loss including conduction loss, and loss over long cycles (50
Hz/60 Hz). Automated measurement of power parameters for up
to two pairs of voltage and current waveforms, such as active
power, apparent power, power factor and so on.
Optimum noise reduction
Real time filters and filters based on MATH functions
The DLM2000 series has two types of filters, one real time
processed at the input circuit and one based on MATH functions.
Since the cutoff frequency can also be finely set, these filters are
effective in rejecting unwanted signals and observing only the
desired signals.
Waveform zoom and search functions
Zoom two locations simultaneously, zoom search and history search
Because the DLM2000 series lets you set zoom factors
independently, you can display two zoomed waveforms with
different time axis scales at the same time. Also, using the
search functions, you can search the long memory and history
memory and instantaneously find desired waveforms that meet
the search criteria.
Can check functions with graphical help
Graphical online help
You can view detailed graphical explanations of the oscilloscope's
functions and operations by pressing the “?” key in the lower left
of the screen. This lets you get help on functions and operations
on screen without having to consult the user’s manual.
Edge trigger
Enhanced triggers
B triggers
Edge
Edge OR
Edge (qualified)
State
Pulse width
State width
Serial: (option) FlexRay/CAN/CAN FD/LIN/
SENT/UART/I2C/SPI
: (standard) user-defined
TV: NTSC/PAL/SDTV/HDTV/user-defined
A Delay B
A to B(n)
Dual bus
(combination trigger of 2 serial busses)
18
Osc
illos
cope
s
Oscilloscopes
Yokogawa’s proprietary new enhanced eight channel
oscilloscope comes with a larger display to enable
waveforms to be easily viewed and the latest functions.
• 8 analog channels or 7 analog channels + 8-bit logic input
• Optional 16-bit logic input
• Up to 2.5 GS/s
• 350 MHz or 500 MHz frequency bandwidth
• 12.1-inch large display
• Large memory of up to 250 Mpoints
• Light, slim, and compact design
The world’s first eight analog channel 500 MHz oscilloscope for faster and more advanced power electronics, automobile electronics, and mechatronics development.
Mixed Signal Oscilloscopes DLM4000
DLM4000
CAN / CAN FD / LIN /
FlexRay / SENT
UART / I2C /SPI
Applications
Features
Motor Control and Inverter/IPM Circuit Development
Simultaneous multi-channel measurements are a necessity for the development of control circuits,
Intelligent Power Module (IPM), and inverter electronics, which are the key to more efficient, compact,
and reliable high-performance motors. Up to 8-channel analog waveform measurement of the DLM4000
empowers engineers in this field.
Examples
• Simultaneous measurement of the 3-line voltage and 3-phase current of a 3-phase motor
• Simultaneous measurement of the gate control signals of 6 IGBTs within an inverter
4ch Limitations of 4 ch ScopeWhole-system measurement is impossible due to a lack of analog input channels when, for example, measuring the overall timing of the
control signals, checking an error of the phase-to-phase balance between 3 phases, and simultaneously measuring the I/O signals of a motor
driver IC.
Limitations of Two Synchronized 4 ch Scopes
Eight channel measurement using two trigger-synchronized oscilloscopes is a possible solution but it does not help increase efficiency because
there are various problems. For example, the data is not reliable due to the lack of guarantee of the synchronization of two oscilloscopes.
Double the space is required and they are difficult to carry around. The different design and operations of each of the two oscilloscopes are
cumbersome. The response is slow and handling of the measurement data is tricky.
Automobile ECU and Integrated Mechatronics Device Development
Electronic Control Unit (ECU) and controller I/O signals must be measured simultaneously at high
speed. To meet this requirement, the DLM4000 offers eight analog channels, logic measurement, and
protocol analysis (communication data decoding) functions such as UART (RS232), I2C, SPI, CAN,
CAN FD, LIN, SENT and FlexRay to help speed up the R&D process.
Examples
• Simultaneous measurement of controller I/O signals and serial bus signals
• Measurement of the analog behavior of logic signals and serial bus signals
4ch Limitations of 4 ch + 16-bit MSOECUs, controllers, and driver ICs handle many I/O signals but the 4-channel + 16-bit MSO cannot measure all the signals. Furthermore, it
measures bus communication signals and digital signals using logic input so it cannot measure waveform quality and noise margin. Therefore,
it is difficult to increase stability and reliability.
Recorder Limitations of Memory RecorderA memory recorder is generally suitable for long-time multi-channel measurement, but due to its low sampling rate and slow waveform
update speed, its performance is not adequate for measuring high-speed signals and communication signals of CPUs and FPGAs, or detecting
noise that causes problems or error signals.
8ch
8ch
19
Osc
illos
cope
s
Oscilloscopes
Model Suffix Code Description
DLM4038*1 Mixed Signal Oscilloscope: 8 ch, 350 MHz
DLM4058*1 Mixed Signal Oscilloscope: 8 ch, 500 MHz
Power cord -D UL/CSA standard
-F VDE standard
-Q BS standard
-R AS standard
-H GB standard
-N NBR standard
Language -HE English Message and Panel
-HC Chinese Message and Panel
-HK Korean Message and Panel
-HG German Message and Panel
-HF French Message and Panel
-HL Italian Message and Panel
-HS Spanish Message and Panel
Option /L16 Logic 16-bit
/B5 Built-in printer
/M1*2 Memory expansion
During continuous measurement: 6.25 Mpoints;
Single mode: 25 Mpoints (when interleave mode ON: 62.5 Mpoints)
/M2*2 Memory expansion
During continuous measurement: 12.5 Mpoints;
Single mode: 62.5 Mpoints (when interleave mode ON: 125 Mpoints)
/M3*2 Memory expansion
During continuous measurement: 25 Mpoints;
Single mode: 125 Mpoints (when interleave mode ON: 250 Mpoints)
/P8*3 Eight probe power connectors
/C1 GP-IB Interface
/C8 Internal storage (7.2 GB)
/G2*4 User defined math
/G3*4 Power supply analysis function
/G4*4 Power supply analysis function (includes /G2)
/F1*5 UART trigger and analysis
/F2*5 I2C+SPI trigger and analysis
/F3*5 UART+I2C+SPI trigger and analysis
/F4*6 CAN+LIN trigger and analysis
/F5*6 FlexRay trigger and analysis
/F6*6 FlexRay+CAN+LIN trigger and analysis
/F7*6 CAN+CAN FD+LIN trigger and analysis
/F8*6 FlexRay+CAN+CAN FD+LIN trigger and analysis
/F9 SENT trigger and analysis
/E1*7 Four additional passive probes (8 in total)
/E2*7 Attach four 701946 probes*8
/E3*7 Attach eight 701946 probes*8
*1: Logic probes are not included. Please order the accessory logic probe 701988/701989 sold separately.*2: Only one of these options can be selected at a time. *3: Specify this option when using current probes or differential probes that don't support probe interface.*4: Only one of these options can be selected at a time.*5: Only one of these options can be selected at a time.*6: Only one of these options can be selected at a time.*7: Only one of these options can be selected at a time.*8: The 701939 passive probes are not included when this option is specified.
Additional Option License for DLM4000*Model Suffix code Description
709820 -G2 User defined math-G3 Power supply analysis function-G4 Power supply analysis function (includes G2)-F1 UART trigger and analysis-F2 I2C + SPI trigger and analysis-F3 UART + I2C + SPI trigger and analysis-F4 CAN + LIN trigger and analysis-F5 FlexRay trigger and analysis -F6 FlexRay + CAN + LIN trigger and analysis-F7 CAN + CAN FD + LIN trigger and analysis-F8 FlexRay + CAN + CAN FD + LIN trigger and analysis-F9 SENT trigger and analysis-X1 F4 -> F7/F6 -> F8 (add CAN FD)
*: Separately sold license product (customer-installable).
Models and Suffix CodesSpecifications
Input Channels: 8 analog channels, or 7 analog channels + 8 logic channels (standard)
8 analog channels + 16 logic channels, or 7 analog channels + 24 logic channels (/L16 option)
Analog Input:Frequency bandwidth: 350 MHz (DLM4038) or 500 MHz(DLM4058)Voltage axis sensitivity setting range: 2 mV/div to 10 V/div for 1 MΩ 2 mV/div to 500 m V/div for 50ΩVoltage axis DC accuracy: ±(1.5% of 8 div + offset voltage accuracy)A/D conversion resolution: 8-bitLogic InputMaximum toggle frequency: 100 MHz (701988) or 250 MHz (701989)Probes that can be used: 701988 and 701989 (701980 and 701981)Minimum input voltage: 500 mVp-p (701988) or 300 mVp-p (701989)Input range: ±40 V (701988) Threshold level ±6 V (701989)Maximum non-destructive input voltage: ±40 V (DC + AC peak) or 28 Vrms (701989)Threshold level setting range: ±40 V (701988) or ±6 V (701989)Common SpecificationsMaximum sampling rate Real-time sampling mode: Interleave OFF: 1.25 GS/s Interleave ON: 2.5 GS/s Repetitive sampling mode: 125 GS/sTime axis setting range: 1 ns/div to 500 s/divMaximum record length: Repeat: 1.25 Mpoints, Single: 6.25 Mpoints,
Single Interleave: 12.5 Mpoints (standard) Repeat: 25 Mpoints, Single: 125 Mpoints,
Single Interleave: 250 Mpoints (/M3 option)History memory maximum data: 2,500 (record length 1.25 kPoints; standard) 50,000 (record length 1.25 kPoints; /M3 option)Trigger modes: Auto, Auto Level, Normal, Single, N-SingleTrigger types: Edge, Edge OR, Edge Qualified, State, Pulse
Width, State Width, TV, Serial Bus (I2C/SPI/UART/CAN/CAN FD/LIN/FlexRay/SENT/UserDefine), A Delay B, A to B (N), Dual Bus, Force
Internal storage: 1.8 GB (standard) or 7.2 GB (/C8 option)Interfaces: USB peripheral connection terminal × 2 USB-PC connection terminal × 1 Ethernet (standard), GP-IB (option)Build-in printer: 112 mm wide, monochrome, thermalDisplay: 12.1-inch color TFT LCD 1024 × 768 (XGA)Dimensions: 426 (W) × 266 (H) × 178 (D) mmWeight: approx. 6.6 kg (with no options)
Two USB terminals
on front panel
Four-direction
selection button
Jog shuttle for facilitating
moving zoom position
Eight analog input channels
(Yokogawa probe interface compliant)
Logic 16-bit input
(option)
12.1 inch
Approx.
6.6kg
Modest 178 mm depthAbout half of the former model DL7480
Channel 8 is convertible
to 8-bit logic input
(standard feature)
The portable eight-channel DLM4000 is the daily instrument of choice.Maximum easiness of use coupled with minimum depth and weight
12.1-inch large LCD display enables eight waveforms to be easily viewed Portable
178 mm355 mm
Former model
DL7480
Trigger level knob
Soft carrying case
(sold separately)
available
20
Osc
illos
cope
s
Oscilloscopes
Classification Product Model No.
Power supply
DescriptionProbe interface terminal (front panel)(*2)
Probe power (option)/probe power supply (sold separately)
Passive
200 MHz passive probe 701938 DC to 200 MHz, 10:1, 1.5 meters
500 MHz passive probe 701939 DC to 500 MHz, 10:1, 1.3 meters
500 MHz Miniature passive probe
701946 DC to 500 MHz, 10:1, 1.2 meters
200 MHz passive probe(wide temperature range)
702906 DC to 200 MHz, 10:1, 2.5 meters-40°C to 85°C
Passive (High-voltage)
100:1 High voltage probe
701944 DC to 400 MHz, 100:1, 1.2 meters
100:1 High voltage probe
701945 DC to 250 MHz, 100:1, 3.0 meters
Active, FET
1.0 GHz active probe(PBA1000)
701912e
DC to 1.0 GHz, 10:1, 1.2 meters
900 MHz FET Probe 700939e
DC to 900 MHz, 1.5 meters
Differential
1 GHz differential probe(PBDH 1000)
701924e
DC to 1 GHz, 50:1 Max. differential input voltage: ±25 V
150 MHz differential probe(PBDH 0150)
701927e
DC to 150 MHz, 50:1, 500:1Max. differential input voltage: ±140 V (50:1), ±1400 V (500:1)
500 MHz differential probe
701920e
DC to 500 MHz, 10:1, Max. differential input voltage: ±12 V
200 MHz differential probe
701922e
DC to 200 MHz, 10:1, Max. differential input voltage: ±20 V
100 MHz differential probe
701921e (*3)
DC to 100 MHz, 10:1, 100:1, Max. differential input voltage: ±70 V (10:1), ±700 V (100:1)
100 MHz differential probe
700924e (*4)
DC to 100 MHz, 100:1, 1000:1, Max. differential input voltage: ±350 V (100:1), ±1400 V (1000:1)
50 MHz high voltagedifferential probe
701926e (*3)
DC to 50 MHz, 100:1, 1000:1, Max. differezntial input voltage: 700 Vpeak (100:1), 7000 Vpeak (1000:1)
15 MHz differential probe
700925e (*4)
DC to 15 MHz, 10:1, 100:1, Max. differential input voltage: ±50 V (10:1), ±500 V (100:1)
Current
Current probe 701917e
DC to 50 MHz 5 Arms, High-sensitivity
Current probe 701918e
DC to 120 MHz 5 Arms, High-sensitivity
Current probe(PBC100)
701928e
DC to 100 MHz 30 Arms
Current probe(PBC050)
701929e
DC to 50 MHz 30 Arms
Current probe 701932e
DC to 100 MHz, 30 Arms
Current probe 701933e
DC to 50 MHz 30 Arms
Current probe 701931e
DC to 2 MHz, 500 Arms
Current probe 701930e
DC to 10 MHz 150 Arms
Logic
100 MHz Logic probe(PBL100)
701988 Input impedance 1 MΩ Max. toggle frequency: 100 MHz
250 MHz Logic probe(PBL250)
701989 Input impedance: 100 kΩ Max. toggle frequency: 250 MHz
Other
De-skew correction signal source
701936 Voltage/current signal de-skewSupports through-type current transformers and a variety of current probes, including large current probes
Probe power supply 701934 Large current output, external probe power supply (4 outputs)
Probe stand 701919 Diameter of attachable probe ϕ 8 to 13 mm Weight : Approx. 1.5 kg
*1: These specifications are a summary. For details, please refer to the Web site, catalog, and other documentation. *2: Available as standard for the DLM2000, DLM6000, DL6000 and DLM4000 series.*3: Can also be battery operated. *4: A power cable (B9852MJ) sold separately is required. Can also be battery operated. In addition to those listed above, there are other accessories available. For details, please refer to the Web site.When using multiple current probes using the probe power of the main unit, ensure that the total power supply current of the current probes does not exceed the maximum output current of the probe power.
Waveform Measuring Oscilloscopes Accessories
21
Osc
illos
cope
s
Oscilloscopes
Instrument control & data analysis on Your PC
Plug-in for MATLAB software
701992Xviewer
Xviewer is a PC software application designed to work with Yokogawa’s DL/DLM series and the ScopeCorders. Xviewer allows you to display DL-acquired waveform data (using the “Viewer” function), perform file transfers, and control DL/DLM series from a PC.
701991MATLAB tool kit
The MATLAB tool kit for the DL series is a plug-in for MATLAB software. The toolkit can be used to control supported instruments using MATLAB or to acquire data from the instruments to use in MATLAB via a communication interface (GP-IB, USB, Ethernet).
In addition to the above, various kinds of accessory software, free software, LabVIEW drivers, and LabWindows/CVI drivers, can be downloaded from our web site.
XWirepuller/Wirepuller(Free software)
With this software, you can display the front panel of the DLM/DL/SL series on the screen of a PC, and monitor waveform signals. You can perform control from the PC using the mouse and keyboard in the same way as you operate the main unit.
Remote Control Measuring Instrument on Your PC
Oscilloscope Application Software Xviewer/MATLAB tool kit
Free data viewer
XviewerLITE(Free software)
XviewerLITE is a free data viewer software with no restriction for period of service for DLM/DL/SL series. It allows you to display acquired ware form on a PC. Zoom, vertical cursor measuremet and CSV format conversion are possible.
22
Dig
ital P
ower
Ana
lyze
rs
Digital Power Analyzers
Digital Power Analyzers
Yokogawa’s PX8000 and WT Series Power Meters and Power Analyzers:
Advanced Technology and High Reliability for a Wide Range of Power Measurement Solutions
*About CW series Clamp-on Power Meters, please refer to the page 65.
Selection Guide
WT Series
Models
Items
WT310E/WT330E
...P28
WT500
...P23
WT3000E
...P24
WT1800
...P26
PX8000
...P30
Features New Entry Class Digital Power Meters
4 models line up, equipping 5 mA range
(WT310E), 40 A range (WT310EH),
and 2 or 3 CH inputs (WT332E/
WT333E)
Standard Communication I/F and
auto-ranging under integration mode
Low-Middle Class Power Analyzer
Compact half rack size and easy use
Max. 1000 V and 40 A input
Simultaneous measurement U, I, P and
those harmonics components
External USB memory for direct data
saving
Top model of Digital Power Analyzer
With basic power accuracy of
±0.04% of total DC and 0.1 Hz-1 MHz
measurement bandwidth, and up to
four input elements, the model provides
higher-accuracy measurement of
inverter Input/Output efficiency.
Middole Class Digital Power Analyzer
Up to six Input elements in one
instrument (3 phase power input from
two systems in one unit)
8.4-Inch XGA TFT Color LCD
Wide voltage and current input range
A power analyzer with capabilities of
transient power measurement and
waveform parameter measurement
Fast sampling up to 100 MS/s, Broad
bandwidth up to 20 MHz (-3 dB), Trend
measurement of each cycle, Specified
period measurement by cursors
Input elements 1(WT310E,WT310EH), 2 (WT332E),
3(WT333E)1 to 3 1 to 4 1 to 6
Module structure, 1 to 4 power
measurement element
Basic power accuracy
(50/60 Hz)± (0.1% of rdg + 0.05% of rng) ± (0.1% of rdg + 0.1% of rng) ± (0.01% of rdg + 0.03% of rng) ± (0.1% of rdg + 0.05% of rng) ± (0.1% of reading + 0.1% of range)
Power measurement
frequency range
DC, 0.1 Hz to 100 kHz
(WT310EH is up to 20 kHz)DC, 0.5 Hz to 100 kHz DC, 0.1 Hz to 1 MHz DC, 0.1 Hz to 1 MHz DC, 0.1 Hz to 1 MHz
Input voltage range
(for crest factor 3)15/30/60/150/300/600/ V 15/30/60/100/150/300/600/1000 V
15/30/60/100/
150/300/600/1000 V
1.5/3/6/10/15/30/60/
100/150/300/600/1000 V
1.5/3/6/10/15/30/60/100/150/300/600/
1000 V
Input current range
(for crest factor 3)
Direct input: 5 m/10 m/20 m/50 m/100 m/
200 m/500 m/1/2/5/10/20 A (WT310E)
Direct input: 1/2/5/10/20/40 A
(WT310EH)
Direct Input: 500m/1/2/5/10/20 A
(WT332E,WT333E)
External input(option): 2.5/5/10 V, or
50 m/100 m/200 m/500 m/1/2 V
Direct input: 500 m/1/2/5/10/20/40 A
External sensor input (option): 50 m/
100 m/200 m/500 m/1/2/5/10 V
Direct input: 0.5/1/2/5/10/20/30 A or
5 m/10 m/20 m/50 m/100 m/200 m/
500 m/1/2 A
External input:
50 m/100 m/200 m/500 m/1/2/5/10 V
30 A and 2 A can be mixed in one unit
Direct input:
10 m/20 m/50 m/100 m/200 m/
500 m/1/2/5 A or 1/2/5/10/20/50 A
External input (option):
50 m/100 m/250 m/500 m/
1/2/5/10 V
5 A and 50 A can be mixed in one unit
Direct input: 10 m/20 m/50 m/100 m/
200 m/500 m/1/2/5 A
External sensor input: 50 m/100 m/
250 m/500 m/1/2.5/5/10 V
Measurement parameters Voltage, Current, Active power,
Reactive power, Apparent power,
Power factor, Phase angle. Peak
voltage, Peak current, frequency, Crest
factor, Integration (power and current),
Harmonic distortion, Harmonic
components
Voltage, Current, Active power, Reactive
power, Apparent power, Power factor,
Phase angle, Peak voltage, Peak
current, Voltage frequency, Current
frequency Active power integration and
Current integration for both charge/
discharge and sold/bought, crest factor,
Efficiency, harmonic analysis
Voltage, Current, Active power, Reactive
power, Apparent power, Power factor,
Phase angle, Peak voltage, Peak current,
Voltage frequency, Current frequency,
Active power integration, Apparent power
integration, Reative power integration,
Current integration, Corrected power,
Crest factor, Efficiency, Harmonic analysis
Voltage, Current, Active power, Apparent
power, Reactive power, Power factor,
Phase angle, Peak voltage, Peak
current, Voltage frequency, Current
frequency, Active power integration,
Current integration, Crest factor,
Form factor, Impedance, Resistance,
Reactance, Corrected Power, Harmonic
analysis
Voltage, Current, Active power, Reactive
power, Apparent power, Power factor,
Phase angle, Peak voltage, Peak
current, Voltage frequency, Current
frequency
Transient voltage/current/power(Trend of
waveform by cycle), Averaged voltage/
current/power by cursor(waveform
parameters calculation)
Display 7 Segment LED, 4 displays 5.7-inch TFT color LCD 8.4-inch TFT color LCD 8.4-inch XGA TFT color LCD 10.4 inch TFT color LCD (XGA)
External dimensions (mm)
(W × H × D)
213 × 88 × 379 (WT310E and WT310EH)
213 × 132 × 379 (WT332E and WT333E)213 × 177 × 408.5 426 × 177 × 459 426 × 177 × 459 355 × 259 × 180
Weight (kg) 3 (WT310E), 5 (WT330E) 6.5 15 15 6.5 (without any options and paper)
23
Dig
ital P
ower
Ana
lyze
rs
Digital Power Analyzers
• Measurement voltage range: (for crest factor 3)
15/30/60/100/150/300/600/1000 V
• Measurement current range: (for crest factor 3)
Direct input 500 m/1/2/5/10/20/40 A
External sensor input (option)
50 m/100 m/200 m/500 m/1/2/5/10 V
• Frequency range:
DC, 0.5 Hz to 100 kHz
• Measurement Accuracy:
Basic Accuracy (45 Hz ≤ f ≤ 66 Hz and DC)
Voltage/Current/Power
± (0.1% of rdg + 0.1% of rng)
• USB interface to PC is standard feature
• Ethernet communication function is available (optional)
• GP-IB communication function is available (optional)
• Effective of power factor (at cos ϕ =0)
± 0.2% of S (apparent power)
• External dimensions:
Approx. 213(W) × 177(H) × 408.5(D) mm
• Weight: Approx. 6.5 kg (with 3-input element)
Compact and easy to use. The Power Analyzer for the renewable energy generation
The WT500 is a low-middle class power analyzer and
it features a 5.7-inch color TFT and half width racking
compact body that enables single-phase and three-
phase power measurement, achieving ±0.2% of total
basic and DC accuracy, maximum input of 1000 Vrms,
40 Arms and a measurement bandwidth up to 100 kHz.
• Accurate efficiency measurement of DC and AC signals
• RMS, MEAN, DC, AC and RMEAN of voltages and currents
simultaneous measurement.
• Simultaneous measurement of normal U/I/P data and those
harmonic data
• As fast as 100 ms data capturing and store data with all channels
• Separate integration functions for charge/discharge or bought/
sold power
• Integration of power, reactive power, apparent power, and
current enables you to determine a device’s average power
consumption
• Harmonics (DC-50th order) and Total harmonic distortion (THD)
can be measured
• Saving measured data directly to external USB memory
• Measurement values can be saved as images or numerical data,
and can be pasted into reports, analyzed in spreadsheet software,
or used in a variety of other ways
• Easy setup with cursor keys
• GP-IB, USB and Ethernet communication are available
WT500 1 input element model
WT500 2 input elements model
WT500 3 input elements model
UL/CSA standard
VDE standard
SAA standard
BS standard
GB standard
GP-IB interface
Ethernet interface
External sensor input for 760201
External sensor input for 760202
External sensor input for 760203
Harmonic Measurement
Delta computation (760202/03 only)
Add-on Frequency Measurement (760202/03 only)
VGA Output
Note: Adding input modules after initial product delivery will require rework at the factory. Please choose your
models and configurations carefully, and inquire with your sales representative if you have any questions.
Model
760201
760202
760203
Power cord
Options
-D
-F
-R
-Q
-H
/C1
/C7
/EX1
/EX2
/EX3
/G5
/DT
/FQ
/V1
Suffix Codes Description
Overview of a Photovoltaic Power Conditioner
Solar cell
module
WT500 Power Analyzer
Booster
converter Load
Power Grid
DC/AC
converter
Power Analyzer WT500
WT500
Bulletin 7602-00E
Basic Specifications
Overview
Features
Model Number and Suffix Codes
24
Dig
ital P
ower
Ana
lyze
rs
Digital Power Analyzers
The World Highest Class*1 Precision and Stability with Basic Power Accuracy: ±0.04% of total(*1: As of May 2016, for power accuracy in a three-phase power meter as investigated by Yokogawa)
Precision Power Analyzer WT3000E
Bulletin WT3000E-01EN
Features
WT3000E
Inverter Motor Load
Input waveform Output waveform
Analog or pulse input(Revolution speed and torque)
The WT3000E has the highest precision of all the Yokogawa power analyzers in the WT series. The WT3000E can be used as a reference instrument for calibration and to measure the power and efficiency of converters such as an inverter. It helps increase efficiency in evaluation and testing.
Basic power accuracy ±0.04% of total, the highest precision of all power analyzers in the WT series, 2 A and 30 A Input Element can be installed together
Up to four input elements to achieve accurate measurement of input and output conversion efficiency
Motor efficiency and total efficiency measurement of the motor option (/MTR)
Simultaneous harmonic measurement without changing measuring modes (option)
Wide bandwidth harmonic measurement between 0.1 Hz and 2.6 kHz of the fundamental waveform (option)
Harmonic measurement compliant with IEC61000-3-2/12 (option)
Voltage fluctuation/flicker measurement compliant with IEC61000-3-3/11 (option)
High-precision measurement of motor/inverter efficiency
Growing interest in energy conservation of late increases the need to evaluate motor/inverter efficiency with high precision. The WT3000E offers up to four voltage and four current inputs and is capable of high-precision measurement of single-phase input and three-phase output to evaluate the inverter efficiency.A motor evaluation function (/MTR option) allows you to observe changes in voltage, current, and power while at the same time observing changes in revolution speed and torque, and calculate and display mechanical power and total efficiency.Also, you can synchronize two units and take measurements, and WTViewerE free software for data acquisition allows you to compare the power of the two units and calculate the efficiency.
Measuring instantaneous peak power in photovoltaic power generation
In photovoltaic power generation, MPPT control varies the voltage to maximize energy harvested from the solar panel. The WT3000E allows you to measure voltage, current, and power, as well as peak voltage and peak current (on the plus and minus sides, respectively). Also, the user-defined MATH allows you to measure the instantaneous peak power (on the plus and minus sides).
Cycle-by-cycle function allows measuring voltage, current, and power
for each cycle
To observe the rising characteristic of a starting motor or the like, you may want to acquire data for each cycle instead of at specified time intervals. The cycle-by-cycle measurement function of the WT3000E allows you to measure the following parameters: voltage, current, active power, apparent power, reactive power, power factor, speed, torque, and mechanical power. Up to 3,000 periods of measurements can be taken.
Example of cycle-by-cycle measurement of three-phase voltage, current, active power, and apparent power
Cycle-by-cycle data computation
MPPT: Maximum Power Point TrackerExample of measurement results of voltage, current, and power under control
Example of power (P1) and instantaneous peakpower on the plus (F1) and minus (F2) sides
Cu
rren
t
Po
we
r
Voltage
Peak power
* This is just an illustration. The actual measurement may be affected by noise.
Example of measurement data display on the primary and secondary sides
Primary side Secondary side
Inverter efficiency
Applications to Utilize WT3000E Precision Power Analyzer’s Capabilities
25
Dig
ital P
ower
Ana
lyze
rs
Digital Power Analyzers
Portable devices, hybrid electric and electric vehicles, etc.
Battery
Example of display of total watt hours (on the plus and minus sides)
Charge
Discharge
LED
Switching
regulatorAC power supply
Model Number and Suffix Code
Specifications
Voltage direct input range : 15/30/60/100/150/300/600/1000 V
Current direct input range : 0.5/1/2/5/10/20/30 A or 5 m/10 m/20 m/
50 m/100 m/200 m/500 m/1/2 A
Current sensor input range : 50 m/100 m/200 m/500 m/1/2/5/10 V
Frequency bandwidth : DC, 0.1 Hz to 1 MHz
Basic accuracy (45 Hz to 66 Hz) (30 A input element)
Voltage/current ±(0.01% of rdg*1 + 0.03% of rng*2)
Power ±(0.01% of rdg*1 + 0.03% of rng*2)
Data update period : Select from 50 ms, 100 ms, 250 ms,
500 ms, 1 s, 2 s, 10 s, and 20 s
Power factor influence: ±0.03% of S (apparent power)
when cos ϕ =0
A/D converter Simultaneous voltage and current
conversion, 16-bit resolution
Conversion speed approx. 5 μs
Display 8.4-inch color TFT LCD monitor
Built-in printer (option) Thermal line-dot, paper width 112 mm
PC card port, USB port (option)
External dimensions : Approx. 426 (W) × 177 (H) × 459 (D)
mm (excluding protrusions)
Weight : Approx. 15 kg (main unit, four input
elements, options)
*1: 1 rdg: reading *2: 1 rng: range
Model Suffix code Description
WT3001E Precision Power Analyzer One Input Element Model
-2A0 -30A1 None 2 A Input Element 30 A ×1 Input Element
-2A1 -30A0 2 A ×1 Input Element None 30 A Input Element
WT3002E Precision Power Analyzer Two Input Elements Model
-2A0 -30A2 None 2 A Input Element 30 A ×2 Input Elements
-2A1 -30A1 2 A ×1 Input Element 30 A ×1 Input Element
-2A2 -30A0 2 A ×2 Input Elements None 30 A Input Element
WT3003E Precision Power Analyzer Three Input Elements Model
-2A0 -30A3 None 2 A Input Element 30 A ×3 Input Elements
-2A1 -30A2 2 A ×1 Input Element 30 A ×2 Input Elements
-2A2 -30A1 2 A ×2 Input Elements 30 A ×1 Input Element
-2A3 -30A0 2 A ×3 Input Elements None 30 A Input Element
WT3004E Precision Power Analyzer Four Input Elements Model
-2A0 -30A4 None 2 A Input Element 30 A ×4 Input Elements
-2A1 -30A3 2 A ×1 Input Element 30 A ×3 Input Elements
-2A2 -30A2 2 A ×2 Input Elements 30 A ×2 Input Elements
-2A3 -30A1 2 A ×3 Input Elements 30 A ×1 Input Element
-2A4 -30A0 2 A ×4 Input Elements None 30 A Input Element
Power Cord -D UL/CSA standard, PSE compliant
-F VDE standard
-H GB standard
-N NBR standard
-Q BS standard
-R AS standard
Options /G6 Advanced Calculation
/B5 Built-in Printer
/FQ Add-On Frequency Measurement
/DA 20 ch DA Output
/V1 VGA Output
/C12* USB Port (PC)
/C2* Serial (RS-232) Interface
/C7 Ethernet Interface
/C5 USB Port (Peripheral)
/FL Voltage Fluctuation/Flicker
/MTR Motor Evaluation Function
* Only one can be selected.
* For common optional accessories, please see page 35
Example of LED driving circuit and measurement
Lighting equipment is shifting from incandescent to fluorescent lamps. Furthermore, in recent years, long-life, low power consumption LEDs are attracting attention. To increase the power conversion efficiency of an LED driving circuit (drive module), it is necessary to measure the voltage, current, and power of input and output with high precision. The WT3000E provides the best-in class accuracy to measure the power conversion efficiency of input and output.
Measuring battery charge and discharge (Ah/Wh)
For battery-powered equipment such as portable devices and electric-powered bicycles, engineers must often perform short-duration charge/discharge tests under actual operating conditions. Since the WT3000E employs a digital sampling system, each rapidly changing charge/discharge current and power can be integrated without gaps. This is effective in the evaluation of ampere-hours and watt-hours for calculating battery life.
Rear panel (4 input elements and options)
2 A and 30 A input Element can be installed together in one unit.
Example of DC voltage, current, and power at three points and conversion efficiency measurement.
26
Dig
ital P
ower
Ana
lyze
rs
Digital Power Analyzers
As three phase mean
One phase current waveform
Broad Ranges Power Measurement with One Unit
The WT1800 High performance power analyzer can
measure both the small currents of products called
energy saving designed as well as the large currents
involved in large-sized loads. As it handles voltages
ranging from 1.5 V to 1000 V, it has a wide variety of
uses. Since 3 phase power can be input from two
separate systems (6 inputs), you only need one WT1800
to simultaneously measure Input/Output signals from
inverters with normal/harmonics data as fast as 50 ms.
• Basic Power Accuracy ±0.15% of total
• DC Power Accuracy ±0.15% of total
• Voltage/Current Bandwidth 5 MHz (-3 dB, typical)
Voltage, 5 A direct input, external sensor input
• Sampling Rate 2 MS/s (16-bit resolution)
• Input Element number Max. 6
• Current Measurement 100 μA to 55 Arms direct
High Performance Power Analyzer WT1800
WT1800
Bulletin WT1800-00EN
Inverter
Input
Convert AC to DC signals
Inverter section
Modulate DC signal and convert to any AC signals indicates measurement points and input to the
power analyzer.
M indicates connecting the motor output to the
motor signal input (/MTR) of the power analyzer
Drive circuitConverter section
Motor Torque/rotation speed sensor
Load
Advantages of WT1800
• 5 MHz range and 2 MS/s high-speed samplingThe vertical resolution in power measurements is one of the important
elements for high-precision measurements.
The WT1800 is capable
of 16-bit high resolution
and approximately 2 MHz
sampling to make it possible
to measure faster signals with
higher precision.
• ms response capability (/HS Option)The High Speed data capturing /HS option can measure
∑Urms, ∑Irms and ∑P from single phase (DC signal)
and three phase devices every 5 ms (When External
Synchronization is OFF) or, 1 ms to 100 ms when External
Synchronization is ON (depending on the frequency of the
clock signal). It outputs data in 1 s blocks to internal/external memory or to
a PC through a communications interface.
The average characteristic is set using the cutoff frequency of the HS
filter for measured data during 5 ms or 1 ms to 100 ms period. The cutoff
frequency can be varied from 1 Hz to 1,000 Hz in 1 Hz steps.
The following measurements can be performed for up to the 500th orderSingle harmonic measurement (/G5 option)Dual harmonic measurement (/G6 option)
• Dual harmonic measurement (/G6 option)The WT1800 is capable of performing two-line simultaneous harmonic
measurements with one unit for the first time in the industry.
The ability to simultaneously measure harmonics for the input and output
signals not only reduces the switching time but also makes it possible to
perform simultaneous data analysis for the input and output, which has not
been possible with the previous models.
Dual harmonicmeasurementDual harmonicmeasurement
Up to the500th orderUp to the
500th order
Simultaneousinput/outputmeasurement
Simultaneousinput/outputmeasurement
Approx.2 MS/s 16-bit
Approx.2 MS/s 16-bit
Voltage/current range
5 MHz
Voltage/current range
5 MHz
Data analysis and graph drawing by data calculation software
Comparison between a phase current waveform and three phase current values of every 5 ms
OverviewThe WT1800 is capable of performing up to 6 power input measurements to make it possible to perform an inverter efficiency test between the input and output in inverter evaluation.
In addition, a motor evaluation function (option) makes it possible to simultaneously monitor voltage, current, and power changes, as well as rotation speed and torque changes.
Overview
Input/Output Efficiency Measurements of Inverters, Matrix converters, Motors, Fans, and Pumps
27
Dig
ital P
ower
Ana
lyze
rs
Digital Power Analyzers
• Measurement Voltage range: (for Crest factor 3) 1.5/3/6/10/15/30/60/100/150/300/600/1000 V• Measurement Direct Current range: (for Crest factor 3) 5 A input element 10 m/20 m/50 m/100 m/200 m/500 m/1/2/5 A 50 A input element 1/2/5/10/20/50 A• Measurement External Current Sensor range: (for Crest Factor 3) 50 m/100 m/200 m/500 m/1/2/5/10 V• Band width: DC, 0.1 Hz to 1 MHz (5 A direct Current input, External Current Sensor input) DC, 0.1 Hz to 200 kHz (50 A direct Current input)• Basic Accuracy: (45 Hz ≤ f ≤ 66 Hz) ±(0.1% of reading + 0.05% of range)• DC Accuracy: ±(0.05% of reading + 0.1% of range)• A/D converter: Sampling frequency 2 MS/s Resolution 16 bit• External dimensions: Approx. 426 (W) × 177 (H) × 459 (D) mm• Weight: Approx. 15 kg (with 6-input element)
*5 A and 50 A Input Element can be installed in one unit
Solar cell module (outdoors)Mega solar system (outdoors)
Pyranometer (photovoltaic power generation)
Vane anemometer (wind power generation)
Power conditioner
Boost converter
AC/DC converter
Current charge control
Power storage system
Charge/discharge
Power sold/bought
Power Flow of Photovoltaic Power Generation
Reverse power flow
Load
Grid interconnection or smart grid
(next-generation power network)Storage batteryPlug-in HV, etc.
indicates measurement points and input
to the power analyzer. (A) indicates
connecting the sensor signals to the
auxiliary input (/AUX) of the power analyzer.
Advantages of WT1800
• Max. 1000 V/50 A x 6-line direct measurement
Direct input terminals in a voltage range from 1.5 V to 1000 V and current range from 10 mA to 5 A or 1 A to 50 A make it possible to perform high-precision measurements without using a current sensor.Furthermore, power conditioner evaluation requires multiple-channel power measurements, such as inputs/outputs from a boost converter, inverter, and storage battery. The WT1800 is capable of providing up to 6 channels of power inputs to make it possible to simultaneously perform power measurements at multiple points with one unit. In addition, two units can be operated in synchronization for multi-channel power evaluation.
Wide voltage/current rangeWide voltage/current range
Synchronizedoperation
Synchronizedoperation
• Maximum Power Peak Tracking (MPPT) measurement
In photovoltaic power generation, an MPPT control is performed to effectively utilize voltage generated by photovoltaic cells in an attempt to maximize the harvested power.The WT1800 is capable of measuring not only the voltage, current, and power but also the voltage, current, and power peak values (plus (+) and minus (-) sides, respectively). Also, the maximum power peak value (plus (+) and minus (-) sides) can be measured.
MPPTMPPT
Maximum powerpeak value
Maximum powerpeak value
Typical voltage, current, and power measurements in MPPT control
* This is just an illustration.Actual measurements are
affected by noise.
Voltage value
Max. power value
Currentvalue
powervalue
* The numbers in the "Description" column have the following meanings.50 A: 50 A input element, 5 A: 5 A input element
Elements are inserted in the order shown starting on the left side on the back.* GPIB, Ethernet and USB communication come standard.
Model Suffix codes Description
WT1801 -01 50 A -10 5 A
-02 50 A 50 AWT1802 -11 5 A 50 A -20 5 A 5 A
-03 50 A 50 A 50 A
WT1803 -12 5 A 50 A 50 A -21 5 A 5 A 50 A -30 5 A 5 A 5 A
-04 50 A 50 A 50 A 50 A -13 5 A 50 A 50 A 50 AWT1804 -22 5 A 5 A 50 A 50 A -31 5 A 5 A 5 A 50 A -40 5 A 5 A 5 A 5 A
-05 50 A 50 A 50 A 50 A 50 A -14 5 A 50 A 50 A 50 A 50 A
WT1805 -23 5 A 5 A 50 A 50 A 50 A -32 5 A 5 A 5 A 50 A 50 A -41 5 A 5 A 5 A 5 A 50 A -50 5 A 5 A 5 A 5 A 5 A
-06 50 A 50 A 50 A 50 A 50 A 50 A -15 5 A 50 A 50 A 50 A 50 A 50 A -24 5 A 5 A 50 A 50 A 50 A 50 AWT1806 -33 5 A 5 A 5 A 50 A 50 A 50 A -42 5 A 5 A 5 A 5 A 50 A 50 A -51 5 A 5 A 5 A 5 A 5 A 50 A -60 5 A 5 A 5 A 5 A 5 A 5 A
-D UL/CSA standard -F VDE standard
Power cord -R AS standard -Q BS standard
-H GB standard-N NBR standard
Languages
-HE Default setting English menu-HG Default setting German menu-HC Default setting Chinese menu-HR Default setting Russian menu
/EX1 External current sensor input for WT1801 /EX2 External current sensor input for WT1802 /EX3 External current sensor input for WT1803 /EX4 External current sensor input for WT1804 /EX5 External current sensor input for WT1805 /EX6 External current sensor input for WT1806 /B5 Built-in printerOptions /G5 Harmonic Measurement /G6 Simltaneous Dual Harmonic Measurement /DT Delta Computation /FQ Add-on Frequency Measurement /V1 RGB output /DA 20-channel DA Outputs /MTR Motor Evaluation Function /AUX
/HS Auxilia
High Speed Data Capturingry Sensor Inputs
WT1800 Single input element
WT1800 2 input elements
WT1800 3 input elements
WT1800 4 input elements
WT1800 5 input elements
WT1800 6 input elements
Standard option
Additional option
Only one can be selected
Only one can be selected
Note: Adding input elements after initial product delivery will require rework at the factory. Please choose your models and configurations carefully, and inquire with your sales representative if you have any questions
Overview
Energy generated by photovoltaic cell modules and wind turbines is converted from DC to AC by a power conditioner. Furthermore, the voltage is converted by a charge control unit for
the storage battery. Minimizing losses in these conversions improves efficiency in the overall energy system. The WT1800 is capable of providing up to 6 channels of power inputs per
unit to make it possible to measure the voltage, current, power, and frequency (for AC) before and after each converter, as well as converter efficiency and charging efficiency.
Power Generation and Conversion Efficiency Measurements in New Energy Markets, including Photovoltaic and Wind Power Generation
Model Number and Suffix Code
Basic Specifications
28
Dig
ital P
ower
Ana
lyze
rs
Digital Power Analyzers
• Basic power accuracy: ±0.15% of total
• Measurement frequency range: DC, 0.1 Hz to 100 kHz (to
20 kHz for WT310EH)
• Fast data update rate: 100 ms
• Auto data update rate function for fluctuating input
• Small current measurement: 5 mA range available (WT310E)
• 40 A large current available (WT310EH)
• Multiple communication interfaces: USB, GP-IB or RS-232
and Ethernet (option and supports the Modbus/TCP
Protocol)• Integration power measurement auto ranging function• Simultaneous measurement of harmonics with voltage, current,
and power (mode switching is not required, but the included a PC software is required )
• Compact half-rack mount size • The included standard PC software allows you to display values,
harmonic bar graph, and waveforms
The WT300E series is the enhanced 5th generation of
Yokogawa’s compact power meter portfolio.
New compact WT300E series for reliable power measurement
Useful in the development of home appliances and office equipment as well as
in the measurement of power consumption and standby power on production line
Digital Power Meters WT300E
WT310E (1 ch) WT310EH
(1 ch, MAX40A)
WT332E (2 ch)/
WT333E (3 ch)
New Functions to Improve Measurement Efficiency
Standard accessories Power cord(1 set), Rubber foot(1 set), Current input protective cover(each 1 set), Start up guide(1 set), Connector (provided
only with /DA4 or /DA12, each 1 set), Safety terminal adapter 758931(provided two adapters in a set times input element number), CD(1 piece,included the startup guide, user guide, instruction manual and the communication manual by PDF data, and Viewer Software)
Model Suffix Code Description
WT310E 1 Input element model
Communication Interface -C1 select one
GP- IB
*USB is standard -C2 RS- 232
Power Cord -D UL, CSA standard, PSE
-F VDE standard
-R AS standard
-Q BS standard
-H GB standard
-N NBR standard
Optional function /C7 Ethernet interface
/EX1 External sensor input 2.5 V/5 V/10 V
/EX2 External sensor input 50 mV/100 mV/200 mV/500 mV/1 V/2 V
/G5 Harmonics Measurement
/DA4 D/A- output (4 CH)
Model Suffix Code Describe
WT310EH 1 Input element /High current model
Communication Interface -C1 select one
GP- IB
*USB is standard -C2 RS- 232
Power Cord -D UL, CSA standard, PSE
-F VDE standard
-R AS standard
-Q BS standard
-H GB standard
-N NBR standard
Optional function /C7 Ethernet interface
/EX1 External sensor input 2.5 V/5 V/10 V
/EX2 External sensor input 50 mV/100 mV/200 mV/500 mV/1 V/2 V
/G5 Harmonics Measurement
/DA4 D/A- output (4 CH)
Model Suffix Code Describe
WT332E 2 Input elements model
WT333E 3 Input elements model
Communication Interface -C1 select one
GP- IB
*USB is standard -C2 RS- 232
Power Cord -D UL, CSA standard, PSE
-F VDE standard
-R AS standard
-Q BS standard
-H GB standard
-N NBR standard
Optional function /C7 Ethernet interface
/EX1 External sensor input 2.5 V/5 V/10 V
/EX2 External sensor input 50 mV/100 mV/200 mV/500 mV/1 V/2 V
/G5 Harmonics Measurement
/DA12 D/A- output (12 CH)
Only one can be selected
Only one can be selected
Only one can be selected
Bulletin WT310-01EN
• Direct voltage input range 15/30/60/150/300/600 V• Direct current input range 5/10/20/50/100/200 mA (WT310E only) 0.5/1/2/5/10/20 A (Common for WT300E series) 1/2/5/10/20/40 A (WT310EH only)• External current input range (optional) 2.5/5/10 V or 50 m/100 m/200 m/500 m/1/2V• Frequency range: DC, 0.1 Hz to 100 kHz (up to 20 kHz for WT310EH)• Basic accuracy (45 Hz to 66 Hz) Voltage/current ±(0.1% of rdg*1 + 0.05% of rng*2) Power ±(0.1% of rdg*1 + 0.05% of rng*2)• Influence of power factor (when cos ϕ =0) Add ±0.1% of S• Data update rate: 100 m/250 m/500 m/1/2/5/10/20s, Auto• External dimensions · WT310E/WT310EH: Approx. 213(W) × 88(H) × 379(D) mm
(excluding protrusions) · WT332E/WT333E: Approx. 213(W) × 132(H) × 379(D) mm
(excluding protrusions)• Weight: Approx. 3.0 kg (WT310E/WT310EH), approx. 5.0 kg (WT332E/
WT333E)
*1 rdg: reading, *2 rng: range
Range skip (range configuration) functionThe WT300E series is equipped with the range skip (range configuration) function of the high-end models, which reduces the range-change time in auto-ranging mode that is long due to the wide voltage and current ranges. This function skips the ranges other than the pre-selected range to speed up the change to the selected range in auto-ranging mode. (The included WTViewerFreePlus software is required for the setting)
Action of Yokogawa’s previous modelInput signal changes
Range change ends
Change available ranges stepwise
Action of WT310E/WT330E series
Range change ends Change to selected next range
Integration measurement auto-ranging functionThis is the industry’s first function to automatically change the range in response to changes of the consumption power and current values in integration mode. This function continues integration even if the level of the input exceeds the maximum of the selected range and the range is changed to a higher level as a result of a rapid change in the conditions. This function eliminates the need for repeating the test even if a range is exceeded, thus reducing the evaluation time. Furthermore, separate power integration for each polarity (±Wh), current integration (Ah), and DC integration (charge/discharge) are also available. (The measurement accuracy depends on the input level and variation. It is recommended to set a fast data update rate.)
Specifications
Features
Models and Suffix Codes
29
Dig
ital P
ower
Ana
lyze
rs
Digital Power Analyzers
WTViewerFreePlus For WT300E Series (included)
WT300E Series can be used for a Variety of Applications
Comparison between WT210/230 series, WT300 series and WT300E series
The WTViewerFreePlus software installed on a PC uses a USB, GP-IB/RS-232, or Ethernet (optional) interface to capture, transfer, and display* five or more numeric values, bar graph of harmonic order components, trend graph of measurement data, or voltage/current waveforms that cannot be displayed on the LED display of the WT300E series. The use of this software extends the application range of the WT300E series. With the aim of simplifying the connection and setup, the details were redesigned so that the communication function is recognized automatically, a dedicated setting window was added, and all measurement data can be displayed simultaneously. * Waveform display requires the /G5 harmonic measurement option.
Setting Window Measurement Window
- Compact half rack mount size helps customers build smaller test systems
with a better Return on Investment (ROI).
- D/A output function and Modbus/TCP Protocol (/C7 option) for data
recording
- Multiple communication interfaces. USB, RS-232 or GP-IB and Ethernet
capability.
The simultaneous measurement of power consumption parameters such as U, I, P, frequency,
Power Factor and Harmonics for production line or QA testing results in reduced tact times.
Thus testing is faster and cheaper. The DA output and communication interfaces enable data to
be remotely and flexibly captured.
Production line or QA testing of electric Devices
PC
- Integration measurement for long period
- D/A output function and Modbus/TCP Protocol (/C7 option) for data
recording
- DC, 0.1 Hz to 100 kHz broad bandwidth capabilityThe WT300E series provides reliable current integration (Ah) and Energy (Wh) measurement for
up to 10,000 hours (approx. 1 year). The D/A option is used to save and monitor the
measurement results (WT310E/WT310EH: 4 ch, WT332E/WT333E: 12 ch). An external recorder
or data logger like, a ScopeCorder, can be used to save this D/A function data along with other
parameters such as temperatures, torque and rotation speed.
Duration testing and efficiency measurement for industrial motors and rotating machinery
Pump
Recorder
D/A outputor Modbus/TCP(/C7 option)
Voltage
Current Probe
Three phase system
Enhancement points from the WT310/WT330 Changed points from the WT210/WT230
WT300E series WT300 series WT210/WT230Basic power measurement accuracy (50/60 Hz)
0.1% of reading + 0.05% of range 0.1% of reading + 0.1% of range 0.1% of reading + 0.1% of range
Influence of power factor When power factor ( ) = 0 (S: apparent power) ±0.1% of S for 45 Hz ≤ f ≤ 66 Hz
When power factor ( ) = 0 (S: apparent power) ±0.2% of S for 45 Hz ≤ f ≤ 66 Hz
When power factor ( ) = 0 (S: apparent power) ±0.2% of S for 45 Hz ≤ f ≤ 66 Hz
Frequency bandwidthDC, 0.1 Hz to 100 kHz
(WT310EH DC, 0.1 Hz to 20 kHz)DC, 0.5 Hz to 100 kHz
(WT310EH DC, 0.5 Hz to 20 kHz)DC, 0.5 Hz to 100 kHz
Direct input Current rangeWT310E: 12 ranges/5 mA to 20 A,
WT310EH: 6 ranges/1 to 40 A WT332E/WT333E: 6 ranges/0.5 to 20 A
WT310: 12 ranges/5 mA to 20 A, WT310HC: 6 ranges/1 to 40 A
WT332/WT333: 6 ranges/0.5 to 20 A
WT210: 12 ranges/5 mA to 20 A, WT230-2ch/WT230-3ch:
6 ranges/0.5 to 20 A
External current inputEX1: 2.5/5/10 [V]
EX2: 50 m/100 m/200 m/500 m/1/2 [V] (OP.)EX1: 2.5/5/10 [V]
EX2: 50 m/100 m/200 m/500 m/1/2 [V] (OP.)EX1: 2.5/5/10 [V]
EX2: 50 m/100 m/200 m [V] (OP.)Expansion of effective input range for voltage & current (CF = 6A)
2% to 260%*1 No No
Expansion of maximum displaying value for voltage & current (CF = 6A)
2% to 280%*2 No No
Simultaneous measurement of RMS, Voltage MEAN & DC
Yes*3 Yes*3 No
Frequency measurement 2 channels (voltage and current) 2 channels (voltage and current) selected voltage or current (one)Number of display item 4 items 4 items 3 itemsSampling rate Approximately 100 kS/s Approximately 100 kS/s Approximately 50 kS/sData Update rate 100 m/250 m/500 m/1/2/5/10/20 sec, Auto 100 m/250 m/500 m/1/2/5 sec 100 m/250 m/500 m/1/2/5 secHarmonic measurement Yes (OP, /G5) Yes (OP, /G5) Yes (OP, /HRM)THD calculation maximum order setting Yes (OP, 1 to 50th) Yes (OP, 1 to 50th) NoAuto ranging of integration Yes Yes No
Communication interface
USB Yes Yes No
GP-IB Yes GP-IB or RS-232 Yes GP-IB or RS-232 Yes (OP) GP-IB or RS-232C
RS-232 Yes GP-IB or RS-232 Yes GP-IB or RS-232 Yes (OP) GP-IB or RS-232CEthernet Yes (OP) Yes (OP) NoModbus/TCP (Ethernet) Yes (OP, /C7) No No
IEEE standard for GP-IB IEEE488.2 IEEE488.2 IEEE488.1 and IEEE488.2Comparator function Yes Yes Yes
Viewer software (setting & data capturing) Free (included) Free (included) Free (download)
*1: WT310EH input range is 2% to 260% (20 A range only up to 200%)
*2: WT310EH input range is 2% to 280% (20 A range only up to 220%)
*3: Simultaneous, mode independent measurement using the WTViewerFreePlus PC software.
* A command compatible mode for the previous WT200 series is prepared. (IEEE488.2 only)
In that mode, the WT300E series and WT300 series works identically to a WT200 series except for the Store (and
recall operation) and the Compare functions.
* Modbus/TCP communication requieres /C7 Ethernet option.
30
Dig
ital P
ower
Ana
lyze
rs
Digital Power Analyzers
Power Analyzer Capable of Measuring Waveform Parameters and Transient Power
• High-speed sampling and wide range measurement
The power of devices driven at a high frequency can be measured at a 100
MS/s sampling rate, at a 12-bit resolution, and in the 20 MHz range*1.
• Waveform measurement function
Instantaneous power waveforms can be displayed as standard in addition to
voltage and current waveforms, and power changes can be observed directly.
Voltage, current, and power waveforms for each cycle can be calculated
and numerical values can be displayed by cursor.
The average voltage, current, and power values in a specified period by
the cursor can be calculated.
Acquisition memory is up to 100 M points per channel (when equipping
the /M2 option), allowing for capturing and displaying detailed waveforms.
• Waveform analysis function
Up to the 500th order harmonic components can be measured
simultaneously (when installing the /G5 option).
2-channel FFT function is available as standard.
• De-skew (phase compensation) function when using an external power
sensor, etc. is available.
• Motor characteristics can be evaluated (mechanical output calculation
with torque and rotation speed input, as well as analog and pulse input).*1: Direct current input at 10 MHz (-3 dB typical)
The PX8000 is a compact sophisticated power analyzer that
can incorporate up to four measurement power elements.
It can calculate the transient voltage, current, and power
for each cycle, the average voltage, current, and power
between cursors, and measure waveform parameters.
Precision Power Scope PX8000
Various functions to measure transient power*2
Trend power calculation for each cyclePower trend waveform for each cycle can be calculated using the User Defined Computation (waveform calculation, MATH) at up to 4 M points. The captured waveforms can be used to obtain the value for a particular cycle and calculate the difference between cycles using the cursor function.
Viewer software PowerViewerPlus
Waveform data in the
displayed entire range
can be displayed on the
numerical display screen.
Waveform parameters to be
calculated can be set in detail.
Start screen
Measurement results display screen
Measured values of waveforms
displayed between cursors
indicating the start and stop
positions can be displayed on
the numerical display screen.
The instantaneous power
waveform indicates the trend
of power change. The value
at any point in time can be
displayed using the cursor.
Settings of the trend
calculation using the User
Defined Computation
(MATH) function.
The cursor (horizontal, vertical, and marker) allows you to display the numerical
data of trend waveform for each cycle calculated using the User Defined Calculation
(MATH).
A PC application software for the PX8000, 760881 PowerViewerPlus allows you to transfer measurement data of the PX8000 to a PC to display and analyze a large amount of waveform data on the PC.
PX8000
Simultaneous calculation and display of instantaneous power waveformsThe PX8000 calculates the instantaneous power waveform simultaneously with the voltage and current waveforms. The instantaneous waveform can be obtained as the product of the voltage and current waveforms that are sampled at the same time. This function is a standard function so no special setting is required. This instantaneous power value can be displayed using the cursor.
Power calculation in a range specified by the cursorThe average numerical values in a range specified by the cursor can be calculated. Values between cursors of waveforms displayed on the screen can be displayed on the upper numerical display screen. The MEASURE function cursor can be used for the measurement in the specified range.
*2: Accuracy is not specified for the numerical data of the measured transient power.
Bulletin PX8000-01EN
Features
31
Dig
ital P
ower
Ana
lyze
rs
Digital Power Analyzers
• Voltage direct input range: 1.5/3/6/10/15/30/60/100/150/300/600/1000 Vrms• Current direct input range: 10 m/20 m/50 m/100 m/200 m/500 m/1/2/5 Arms• Current sensor input range: 50 m/100 m/200 m/500 m/1/2/5/10 Vrms• Frequency range: DC to 20 MHz (-3 dB, voltage and current
sensor input) DC to 10 MHz (-3 dB, current direct input)• Power basic accuracy (45 Hz to 66 Hz) ±(0.1% of reading + 0.1% of range)• Influence of power factor error (cos ϕ = 0): ±0.15% of S (apparent power)• A/D converter: Maximum sampling rate 100 MS/s Resolution 12-bit• Acquisition memory: Standard: 10 M points per channel Max: 100 M points per channel (/M2 option)• Maximum waveform viewing time: 20 minutes (not dependent on the memory size)• History memory: This function can save up 1,000 records of waveform
data and display and calculate them as needed(when the /M2 option installed)
• Waveform display: Up to 16 waveforms can be displayed. Voltage and current waveforms and simultaneous
power waveform can be displayed.• Snapshot: Waveform at an arbitrary moment on the screen can
be saved. • De-skew (phase compensation) function: Phase difference between the voltage and current
modules is compensated.• Trend measurement (waveform measurement, MATH): Voltage, current, and power waveform calculation for
each cycle• Calculation in the specified period (waveform parameter calculation, MEASURE):
Average value between cursors can be measured.• Simultaneous harmonic measurement: Up to the 500th order harmonic measurement (/G5 option)• 2-channel FFT function available as standard• Printer: Screens can be copied (/B5 option)• External storage: USB port (×2), SD card• Video output: RGB analog, video output• Display unit: 10.4-inch color TFT XGA display• GP-IB, Ethernet, and USB communication available as standard• IRIG function: Data measured with multiple PX8000 units can be
synchronized (/C20 option)• Sensor power supply 4CH DC power supply ±15Vdc Max. of 1A/CH• External dimensions: 355 (W) × 259 (H) × 180 (D) mm (excluding protrusions)• Weight: Approximately 6.5 kg (main unit only, excluding paper and options)* For common options and accessories, see Page 35.
Power measurement elements (voltage and current modules) and Auxiliary (AUX) module
Application example: Inverter evaluation using the PX8000 and DL850EV
Overview of the evaluation with the PX8000 and DL850EVElectric vehicles (EVs) and hybrid electric vehicles (HEV) are made of a large number of electrical and mechanical parts. To evaluate their efficiency, electrical parts and mechanical parts must be measurement simultaneously. The DL850EV is a data acquisition instrument that can measure many types of physical quantities at multiple points simultaneously. On the other hand, the PX8000 measures the efficiency of the inverter and the motor, as well as transient changes at every moment based on the electrical signals of voltage and current and the mechanical output calculated from the torque and rotation speed.
Functions to prevent mismatch between the voltage and current modules
Safety design
Power measurement elements comprising a pair of the voltage module (760811) and current module (760812/760813) are required to measure power. You need to connect at least one set of power measurement element, the voltage module to slot 1 and the current module to slot 2.Note: Up to 3 AUX modules can be connected to odd number slots 3, 5, and 7 except for slot 1.
Current module
760813 760812
Voltage module
760811
AUX module
DL850EV
PX8000
CAN
Power measurement elements
- Warning message- Check on the overview screen ‘(you can
check paired modules)
Different types of voltage input terminal and current input terminal are used to keep the user from confusing one from the other.
Voltage input
terminal type
(female-type
safety terminal)
Current input
terminal type
(male-type
safety terminal)
Inverter
Input (2)(1) (3)
(4)
Drive circuitBoost
converter
Drive motor
Torque/rotation speed sensor
Load
Battery
Modulate the DC signal to convertit to an arbitrary AC signal
(1) Measuring battery output (DC)
(2),(3) Inverter output measurement and transient
power measurement
(4) Mechanical output measurement of motor
(torque and rotation speed measurements)
Product name Model Suffix code Description
Precision Power Scope
PX8000 Precision Power Scope main unit
-DUL and CSA standards(PSE compliant, 3-pole type)
-F VDE standard
-R AS standard
-Q BS standard
-H GB standard
-N NBR standard
-HE English menu language
/B5 Built-in printer
/C20 IRIG function
/G5 Simultaneous harmonic measurement
/M1*1
/M2*1
50 M point/CH memory extension100 M point/CH memory extension
/P4 4 CH probe power output
/PD 4 CH sensor power output
Product name Model Suffix code Description
Voltage Module 760811 *2 Necessary to order the same number as that of the 760812/760813 Current Modules at the same time
Current Module 760812 *2 Necessary to order the same number of that of the 760811 Voltage Modules at the same time
760813 *2 Necessary to order the same number of that of the 760811 Voltage Modules at the same time The 760813 is direct current input only.
Auxiliary (AUX) Module
760851 Can measure the sensor signals of torque and rotation speed on 2 channels
*1 Selection of both /M1 and /M2 is not available for one main frame. The standard memory length is 10
M points/CH.
*2 The power value will be calibrated using a pair of Voltage (760811) and Current (760812/760813)
modules, therefore an equal quantity of these must be ordered together.
Product name Model Suffix code Description
Power Viewer Plus
760881 Dedicated PC application software for PX8000. It is a waveform data analysis software
<Cautions regarding the installation of modules and their location>
- The PX8000 has a maximum of 8 slots for installing modules.
- It is required to equip the PX8000 main frame with at least one Voltage Module and one Current Module
in slots 1 and 2 to create one Power Measurement Element. The PX8000 can be equipped with a
maximum of three additional Power Measurement Elements.
- When modules are ordered with the PX8000 main frame, the modules are factory installed in the main
frame up to a combined maximum of 4 power measurement elements and auxiliary modules. Priority is
given to the installation of power measurement elements.
- The location of modules can be changed by the customer. However, slot 1 must be always containing a
Voltage Module and slot 2 must always contain a Current Module.
- Power values are calibrated using one Voltage Module and one Current Module, so the same number of
these modules must be ordered together. In the case of service, repair or re-calibration, both modules
must be sent together to the service department.
- Up to 3 Auxiliary (AUX) Modules can be installed in odd numbered slot only (3, 5 and 7). Odd numbered
slots (3, 5 and 7) are also used to install additional Voltage Modules, and even numbered slots (4, 6 and
8) for additional Current Modules.
Torque/rotation speedVoltage/currentTemperature
Vibration
Specifications PX8000 Model and Suffix Codes
32
Dig
ital P
ower
Ana
lyze
rs
Digital Power Analyzers
751552Current Clamp-on Probe, AC 1000 Arms (1400 A Peak)
Measurement bandwidth: 30 Hz to 5 kHz Basic accuracy: ± 0.3% of reading Maximum allowable input: AC 1000 Arms
1400 Apk (AC) Current output type: 1 mA/A
To connect this probe to the WT series, you need the Model 758921 (Fork terminal adapter) and Model 758917 (Measurement lead set) accessories sold separately. For details, please see the Power Meter Accessories Catalog (Bulletin CT1000-00E).
751522 / 751524 AC/DC Current Sensor Unit. DC, up to 100 kHz, up to 1000 A peak
Large current measurement: DC: 0 to 1000 A / AC: 1000 A peak
Wide measurement frequency range: DC to 100 kHz (-3 dB)
High-precision fundamental accuracy: +/- (0.05% of rdg* + 40 μA)
Superior noise withstanding ability and CMRR characteristic due to optimized casing design
Calibration enabled in combination with WT Series
758917 758921
Accessory for Digital Power Meters and Power Analyzer
Accessories for Digital Power meters and Power Analyzers
Current Probe 751552
Current Sensor Unit 751522 / 751524
Wide Variety of precision Current Sensors for broad applications
AC/DC Current Sensor CT60/CT200/CT1000
CT60/CT200/CT1000AC/DC Current Sensors, DC, up to 800 kHz, up to 1000 A peak
Rated Current CT60 DC: 0 to 60 A, AC 60 A peak CT200 DC: 0 to 200 A, AC 200 A peak CT1000 DC: 0 to 1000 A, AC 1000 A peak
Frequency bandwidth CT60 DC to 800 kHz (-3 dB) CT200 DC to 500 kHz (-3 dB) CT1000 DC to 300 kHz (-3 dB)
Measurement Accuracy DC, 50/60 Hz: ± (0.05% of reading + 30 μA)
Power Supply Voltage ± (15 V + 5%)Bulletin CT1000-00E
Bulletin CT1000-00E
Bulletin CT1000-00E
751522 : For Single-Phase
751524 : For Three-Phase
33
Dig
ital P
ower
Ana
lyze
rs
Digital Power Analyzers
Communication functions supported by WTViewer 760122
Model number GP-IB Serial (RS-232) Ethernet USB
WT1800
WT500
: Supported (by WT as standard) : Supported (by WT as an option) : Not supported (by WT)
PC-based Control and Data Acquisition
4 units synchronization
WTViewer is a software application that allows you to load numeric and waveform data mea-
sured with the WT1800 High performance Power Analyzer, or WT500 Power Analyzer to a PC
via GP-IB, or USB (for WT1800/WT500) communications. It also lets you view the waveform
data, and analyze and save the numeric data.
WTViewer
760122
Main Features of WTViewer Numeric, waveform, harmonic, and trend displays Manual save function: With one click you can save only desired data at the right timing.
Data conversion to CSV: You can save waveforms, numeric data, and screen images to a PC.
You can control multiple WT series units of the same specifications from a PC. Note: The functionality differs slightly depending on the model. For details, please
refer to the specifications of your desired model.
Power Consumption Measurement Software
Free Software
The IEC62301 Ed 2.0 is a reference standard in the EN 50564: 2011 Directive. This soft-ware corresponds to a test method of those two standards.
Allows you to acquire the necessary data such as a power value with simple opera-tions such as just pressing the Start button.
Allows you to print out a report on the measurement results.
(The free software can be downloaded from Yokogawa’s website)
Power Consumption Measurement Software
File conversion function
WT1800
Maximum connections
FTP server/client function
GP-IB connection
1 to 4 units Not available
USB communication
1 to 4 units Not available
Ethernet communication
1 to 4 units Available
WT500
Maximum connections
FTP server
function
GP-IB connection
1 to 4 units Not available
Ethernet communication
1 to 4 units Available
USB communication
1 to 4 units Not available
GP-IB
(WT1800/WT3000E/WT310E)
RS-232
(WT3000E/WT310E)
Ethernet
(WT1800/WT3000E/WT310E)
USB
(WT1800/WT3000E/WT310E)
WT3000E
Example of a printed report
Example of an initial setup screen
Example of a screen to set the measurement conditions
Example of a measurement screen
WT Series Accessory Software 760122 and Power Consumption Measurement Software
WT1800
WT310E
FTP function Command monitor
34
Dig
ital P
ower
Ana
lyze
rs
Digital Power Analyzers
WT Series Accessory Software 761922 IEC regulation software
Harmonic/Flicker Measurement Software
761922
Support for IEC Standards Testing
Example of a printed report
AC Power Supply
WT3000E Precision Power Analyzer
Recommended model:
WT3001E-2A0-30A1-x/G6/FL
Reference ImpedanceNetwork
GP-IB or Ethernet
Less than 20 A single phase
Example of a measurement screen
Launcher screen
Example of an initial setup screen
AC Power Supply
WT3000E Precision Power AnalyzerRecommended model:
WT3003E-2A0-30A3-x/G6/FQ/FL* The external sensor input of the WT3000E is used.
Reference Impedance Network
GP-IB or Ethernet
More than 20 A single phase
Current transducerpower supply Shunt resistor
Current sensor
A special order model is available that includes a current transducer and shunt resistor set.
*You need to purchase the power supply and cable separately.
C
Allows you to judge high current equipment with input current of 16 A or more per phase (IEC61000-3-11/-3-12)
Support for the method that does not consider interharmonics in the window of 16 cycles specified in IEC61000-4-7
Best-in-class high-precision current and voltage measurements (also allows you to calculate the limits of the standard)
All Judgment graph display shows a list of all the measurement results in a time series by order.
Allows you to measure harmonics for up to 24 hours, so capable of measuring equip-ment that needs more than one hour for one cycle.
Continuous data acquisition at a measurement interval of 200 ms ensures continuous measurement over a long period of time with no missing data
Support for the standard tests of single- and three-phase equipment
35
Dig
ital P
ower
Ana
lyze
rs
Digital Power Analyzers
WT30
00E
WT18
00
WT50
0
WT31
0E/W
T330E
Product Part No. Description
1:1 BNC safety adapter lead
701901 1000 Vrms-CAT II, 1.8 m longSafety BNC (male) to safety banana (female) use in combination with 701959, 701954, 758921, 758922 or 758929
• • • •Measurement leads
758917 Two leads in a set. Use 758917 in combination with 758922 or 758929.Total length: 75 cmRating: 1000 V, 32 A
• • • • •Small alligator adapters
758922 For connection to measurement leads (758917). Two in a set.Rating: 300 V • • • • •
Large alligator adapters
758929 For connection to measurement leads (758917). Two in a set.Rating: 1000 V • • • • •
Safety terminal adapter set
758923 Spring-hold type. Two adapters in a set.
• • • • •Safety terminal adapter set
B8213ZD Screw-fastened adapters for voltage input. Two adapters in a set. 1.5 mm Allen wrench for tightening is required. • • • • •
Safety terminal adapter set
B8213ZA Screw-fastened adapters for current input of PX8000. Two adapters in a set. Allen wrench for tightening is required. •
Fork terminal adapter
758921 Two adapters (red and black) to a set. Used when attaching banana plug to binding post. • • • •
Conversion adapter
758924 For conversion between BNC and female banana plug
• • • •Conversion adapter
366971 9-pin/25-pin conversion adapter
•External sensor cable
B9284LK For the external input of the WT series. Length: 50 cm • • • • •
BNC cable 366924 BNC cable BNC–BNC, 1 m
• • • •BNC cable 366925 BNC cable BNC–BNC, 2 m
• • • •26 pin cable 705926 For/DA4 and/DA12 option
•Current sensor cable
A1559WL Cable length 3 m
•Current sensor cable
A1560WL Cable length 5 m
•Shunt resistor box A1323EZ 5 ohm ±0.05% for CT1000
•Shunt resistor box A1325EZ 20 ohm ±0.02% for CT200 and CT60
•Rack mounting kit 751535-E4 For EIA
• • •Rack mounting kit 751535-J4 For JIS
• • •Rack mounting kit 751533-E2 For WT310E/WT310EH EIA standalone installation
•Rack mounting kit 751533-J2 For WT310E/WT310EH JIS standalone installation
•Rack mounting kit 751534-E2 For WT310E/WT310EH EIA connected installation
•Rack mounting kit 751534-J2 For WT310E/WT310EH JIS connected installation
•Rack mounting kit 751533-E3 For WT332E/WT333E EIA standalone installation
•Rack mounting kit 751533-J3 For WT332E/WT333E JIS standalone installation
•Rack mounting kit 751534-E3 For WT332E/WT333E EIA connected installation
•Rack mounting kit 751534-J3 For WT332E/WT333E JIS connected installation
•
Digital Power Analyzers Accessories List Accessories List
PX8000
36
Gen
erat
ors,
Sou
rces
,M
anom
eter
s et
c.
Generators, Sources, Manometers etc.
Higher Accuracy — The New Advanced DC Voltage/Current Source
DC Voltage/ Current Source GS200
Functions and Specifications
Functions
The GS200 generates high accuracy, high stability, high resolution, and
extremely low-noise DC voltage and current signals that are required for
many applications.
• Voltage source up to ±32 V and current source up to ±200 mA
• 5 1/2-digit, ±120,000-count output resolution
• Voltage and current simple monitoring feature (optional)
• Programmable output up to 10,000 points
• Built-in USB mass storage device
• Channel expansion through synchronous operation
Voltage and Current Source Range
The GS200 can perform four-quadrant operation by operating as a current
source or a current sink in the range of ±30 V and ±200 mA. When the
GS200 is sinking current, it can operate over the exact same range as when
it is operating as a current source. You can use the GS200 not just as a
highly accurate voltage source but also as a highly accurate constant-current
electronic load.
-30 V 30 V
-200 mA
200 mA
Source Sink
Sink Source
Voltage
Current
The monitoring feature can be used to:
• Check that current is flowing.
• Check and inspect current consumption
• Log fluctuations in the load current
• Record I-V characteristics GS200
Vcc application
Load current measurement
GS200 Model and Suffix Codes
Model Suffix Code Description
GS210 DC voltage/current source (front panel output terminals)
GS211 DC voltage/current source (rear panel output terminals)
Supply voltage -1 100 VAC, 50/60 Hz
-4 120 VAC, 50/60 Hz
-7 230 VAC, 50/60 Hz
Power cord -D UL/CSA standard
-F VDE standard
-R AS standard
-Q BS standard
-H GB standard
Options /MON Monitoring function
/C10 Ethernet interface function
USB STORAGEDrag & Drop
Drag & Drop
USB Source
• Voltage source
Range : 10 mV, 100 mV, 1 V, 10 V, 30 V (Use a highly
accurate voltage divider at 10 mV and 100 mV
ranges)
Maximum output : ±200 mA (at 1 V, 10 V, and 30 V ranges)
• Current source
Range : 1 mA, 10 mA, 100 mA, 200 mA
Maximum output : ±30 V
• Program Feature
Maximum number of steps
: 10,000
Trigger source : Internal timer (0.1s resolution), External,
Step input, measurement end
Monitoring (option)
Function : Voltage (during current generation),
Current (during voltage generation)
Integration time : 1 to 25 PLC (Power Line Cycle)
Trigger source : Internal timer (0.1 s resolution), READY,
Communication and Immediate
Delay : 0 to 999,999 ms (1 ms resolution)
Maximum storage : 10,000 points
External Input and Output
Input signal : TRIG IN, OUTPUT IN
Output signal : TRIG OUT, OUTPUT OUT, READY OUT
Connector : RJ-11 connector
BNC connector (Select any one of the signals for
both the input and output)
Input and output level : TTL
Minimum pulse width : 10 μs
Interface
• GP-IB interface
• USB interface
• Ethernet interface (option) 100BASE-TX/10BASE-T
General Specifications
• Display : 256 × 64 dot vacuum fluorescent display
• External dimensions : Approx. 213 (W) × 88 (H) × 350 (D) mm
(excluding protrusions)
• Weight : Approx. 5 kg
37
Gen
erat
ors,
Sou
rces
,M
anom
eter
s et
c.
Generators, Sources, Manometers etc.
Multi Channel Source Measure Unit GS820
Highly Accurate 2-Channel Voltage/Current Source Measure Unit
Features
The GS820 is a highly accurate and highly functional 2-channel
programmable DC voltage/current source that incorporates voltage/current
generation and measurement functions.
• Isolated 2-channel source and measurement function
• Basic accuracy : ±0.02% (DC voltage source)
• 1 pA resolution at extremely small current range 200 nA
• Generate arbitrary waveforms consisting of up to 100,000 points at 100-μs
intervals
• Channel expansion through master-slave synchronization link
• Fast test speeds
• 16-bit digital I/O (model 765602/765612)
Source and Measurement Range
Four-quadrant operation consisting of source operation (current source)
and sink operation (current sink) is available. The output and measurement
resolutions are 5.5 digits. Two models are available for your application.
18 V range model (765601/02)
Voltage ranges: 200 mV/2 V/7 V/18 V
Maximum output:
±3.2 A (at an output voltage of ±7 V
or less)
±1.2 A (at an output voltage of ±18 V
or less)
Current ranges: 200 nA/2 μA/20 μA/200 μA/
2 mA/20 mA/200 mA/1 A/3 A
Maximum output: ±18 V (at an output current of ±1.2 A or less)
±7 V (at an output current of ±3.2 A or less)
50 V range model (765611/12)
Voltage ranges:
200 mV/2 V/20 V/50 V
Maximum output:
±1.2 A (at an output
voltage of ±20 V or less)
±0.6 A (at an output
voltage of ±50 V or less)
Current ranges: 200 nA/2 μA/20 μA/200 μA/2 mA/
20 mA/200 mA/0.5 A/1 A
Maximum output: ±50 V (at an output current of ±0.6 A or less)
±20 V (at an output current of ±1.2 A or less)
Model and Suffix code
USB STORAGEDrag & Drop
Drag & Drop
USB
Source and Measurement Functions• Voltage source and current measurement (VS&IM)• Current source and voltage measurement (IS&VM)• Voltage source (VS)• Current source (IS)• Voltmeter (VM)• Ammeter (IM)• Resistance meter (IS&VM)SourceFunction: Voltage or currentMode: DC or pulse (pulse width: 50 μs to 3,600 s)Sweep mode: Linear, logarithmic or program (up to 100,000 steps)Trigger source: External or internal timers 1 and 2 (period: 100 μs to 3,600 s)Sweep start source: External or internal timers 1 and 2 (period: 100 μs to 3,600 s)Source delay: 15 μ to 3,600 sResponse characteristics: Normal or stableMeasurementFunction: Voltage, current, auto, voltmeter mode, ammeter mode or resistance meter modeIntegration time: 0.001 to 25 PLC (Power Line Cycle)Trigger source: External or internal timers 1 and 2 (period: 100 μs to 3,600 s)Measure delay: 0 μs to 3,600 sMeasurement data storage: Up to 100,000 data pointsAverage: Moving average (average count: 2 to 256)Voltage sense: Two-wire system or four-wire systemAuto zero: Measure the internal zero reference every measurement and correct the measured valueNULL computation: Computes the difference with respect to the current measuredvalue or user-defined valueUser-defined computation: Computes user-defined equations in real-timeExternal I/O and Communication Interface• BNC I/O• Digital I/O D-Sub 15-pin (model 765601/11) Half-pitch 50-pin (model 765602/12)• I/O for synchronized Operation RJ-11 connector 6-pin, BNC connector• GPIB• RS232• USB• Ethernet 100 BASE-TX/10 BASE-TDisplay 256 × 64 dot VFDDimensions Approx. 213(W) × 132(H) × 450(D) mmWeight Approx. 8 kg
Functions
Model Suffix Code Discription
765601GS820 Multi Channel Source Measure Unit 18 V range/2-bit digital I/O model
765602GS820 Multi Channel Source Measure Unit 18 V range/16-bit digital I/O model
765611GS820 Multi Channel Source Measure Unit 50 V range/2-bit digital I/O model
765612GS820 Multi Channel Source Measure Unit 50 V range/16-bit digital I/O model
Power cord
-D UL/CSA standard, PSE compliant
-F VDE standard
-R AS standard
-Q BS standard
-H GB standard
-N NBR standard
1.2 A
1.2 A
7 V7 V
3.2 A
3.2 A
18 V18 V
Voltage
Current
Sink
Source
Source
Sink
0.6 A
0.6 A
20 V20 V
1.2 A
1.2 A
50 V50 V
Voltage
Current
Sink
Source
Source
Sink
38
Gen
erat
ors,
Sou
rces
,M
anom
eter
s et
c.
Generators, Sources, Manometers etc.
Combines High Accuracy and High Speed in a Single Unit
The GS610 is a highly accurate and highly functional programmable
voltage/current source that incorporates voltage/current generation and
measurement functions. The maximum output voltage and current are
110 V and 3.2 A, respectively. Evaluation of over a wide range of basic
electrical characteristics is possible, because the GS610 can operate as a
current source or a current sink.
• Source and sink operation up to 110 V/3.2 A (four-quadrant operation)
• Basic accuracy: ±0.02% *1
• Sweep output at up to 100 μs intervals
• Comes with abundant sweep patterns (linear, logarithmic, and arbitrary)
• Stores up to 65,535 points of source measure data in the internal memory
• Easy file operation with the USB storage function
• Remote control and FTP using Web server function (Optional)
*1: DC voltage generation
Features
Voltage/Current Generation and Measurement Range
Four-dimensional operation with source operation (current source) and
sink operation (current sink) is possible at up to 110 V, 3.2 A, and 60 W.
The output and measurement resolutions are 5.5 digits.
Voltage generation/measurement range: 200mV to 110 V
Current generation/measurement range: 20 μA to 3.2 A
Maximum output current:
±3.2 A (at an output voltage of ±12 V or less)
±2 A (at an output voltage of ±30 V or less)
±1 A (at an output voltage of ±60 V or less)
±0.5 A (at an output voltage of ±110 V or less)
3.2
2.0
1.0
0.5
-0.5
0 12-12 30-30 60-60 110-110
-1.0
-2.0
-3.2
Voltage (V)
Current (A)
Source
Source
Sink
Sink
Source Measure Unit GS610
USB STORAGEDrag & Drop
Drag & Drop
USB
Model and Suffix code
Functions
Model Suffix Codes Description
765501 GS610 Source Measure Unit
Power cord
-D UL/CSA standard
-F VDE standard
-R AS standard
-Q BS standard
-H GB standard
Option /C10 Ethernet interface
Function
• Generation
Generation function : Voltage or current
Generation mode : DC or pulse
Sweep mode : Linear, logarithmic or program (up to 65,535
steps)
• Measurement
Measurement function : DC voltage, DC current and resistance
Measurement data storage : Up to 65,535 data points
Average : Block average or moving average
(Specified count: 2 to 256)
• Trigger
Trigger mode : Internal, external and immediate
• Time setting
Pulse width : 100 μs to 3,600 s, 1 μs resolution
Period time : 1 ms to 3,600 s, 1 μs resolution
(during source and measure operation)
100 μs to 3,600 s, 1 μs resolution
(during source-only operation)
Source delay : 1 μs to 3,600 s, 1 μs resolution
Measurement delay : 1 μs to 3,600 s, 1μs resolution
Integration time : 250 μs, 1 ms, 4 ms, 16.6 ms/20 ms,100 ms,
200 ms
(auto detect from the power supply frequency
when the power is turned ON for 16.6 ms/20 ms)
• Computation function
Operators: +[addition], -[subtraction], *[multiplication], /[division] and
^ [exponentiation]
Functions: ABS(), EXP(), LN(), LOG(), SQRT(), SIN(), COS(), TAN(),
ASIN(), ACOS(), ATAN(), SINH(), COSH(), TANH(),
RAND()
External Input/Output
• Synchronization signal input/output (TRIG, SWEEP, CTRL IN and
OUT) (BNC)
• External input/output (D-Sub 15-pin)
• GP-IB interface
• RS-232 interface
• USB interface
• Ethernet interface (option) 100BASE-TX/10BASE-T
Internal memory
ROM : 4 MB Area for storing setup and output pattern files
RAM : 4 MB Area for storing the measured results
(cleared when the power is turned OFF)
Display : 256 × 64 dot vacuum fluorescent display
External dimensions : Approx. 213 (W) × 132 (H) × 400 (D) mm
(excluding protrusions)
Weight : Approx. 7 kg
39
Gen
erat
ors,
Sou
rces
,M
anom
eter
s et
c.
Generators, Sources, Manometers etc.
GS Series Accessory Software 765670 Curve Tracer Software for the GS series
Features
Simple system configuration, easy connection, compact and light
This system is configured by connecting the GS series Source Measure Unit
to a PC that contains the 765670 Curve Tracer Software via USB.
You can perform high speed, high-accuracy curve tracing despite its compact
size, light weight, and simple system configuration.
Real-time, High-Speed Drawing
The GS series is high-speed communication and sweep features allow high-
speed graph update rate up to 25 pages/s(GS820).
You can use the real-time curve tracer with comfort.
Field of Applications
• Discrete semiconductors such as transistors and diodes
• Analog ICs such as voltage regulators and op- amps
• MOS logic and other digital ICs
• LEDs and other optical devices
• Solar battery cells
Drawing Speed (times/s; reference values)
Plot PointsModel Number
GS610 GS820
20 20 25
50 10 16
100 5 11
200 3 6
Measurement conditions: Using Core2Duo CPU, 1.5 GHz, USB 2.0, and LabVIEWMeasurement integration time: 0.001 PLC for GS820 / 250 μs for GS610
http://tmi.yokogawa.com/products/generators-sources/
source-measure-units/765670-curve-tracer-software/
• Graph drawing:
Voltage vs. current, voltage vs. voltage, gain vs. voltage, voltage vs. timestamp,
current vs. voltage, current vs. current, gain vs. current, current vs. timestamp
Sweep axis: Voltage source or current source
Measurement axis: Voltage measurement or current
measurement
Parameter: Voltage source or current source
Sweep shape: Ramp (linear or log), triangle (linear or log), rectangle
Sweep points: 5, 10, 20, 50, 100, 200, 1000
Scaling: Auto scale or fixed scale
Averaging count: 2 to 100
• Analysis feature:
Cursor, zoom & scroll, reference curve designation
• File operations:
CSV data storage and loading, graphic image storage, panel image storage,
setup storage and recall
Specifications
Product Overview
This product is a high-speed, high-accuracy real-time I-V curve tracer that
consists of the GS series Source Measure Unit and the 765670 Curve Tracer
Software. It is particularly well-suited to DC parametric tests of minute
signals.
Examples of Measurements of Characteristics
FET VDS-ID characteristics
G
S
D
AVGS
Connection diagram
Measurement results
0 250m 750m 1 1.25 1.5 1.75 2 2.25 2.5 2.75 3 3.25 3.5 3.75 4 4.25 4.5 4.75 5
Sweep (V)
Measu
re (
A)
8.5m
8.5m
7.5m
7m
6.5m
6m
5.5m
5m
4.5m
4m
3.5m
3m
2.5m
2m
1.5m
1m
500
0
0 V-0.1 V-0.2 V-0.3 V
VDS
ID
Channel 1V source
Channel 2V sweep
I measurement
VGS
System configuration illustration
USB
GS820 PC
USB
USB
GS610 PC
40
Gen
erat
ors,
Sou
rces
,M
anom
eter
s et
c.
Generators, Sources, Manometers etc.
DC calibrator for temperature, voltage, and current
Features
Main specification
Precision DC Calibrator 2553A
Model and Suffix code
Main specification
The 2553A outputs DC voltage in the range of ±32 V and DC current in the
range of ±120 mA. In addition to being able to calibrate analog meters, the
2553A can calibrate thermometers and temperature controllers that utilize a
thermocouple or RTD.
• High accuracy DC voltage : ±75 ppm (0.0075%) DC current : ±120 ppm (0.012%)• High stability : ±15 ppm (0.0015%) / h• Low noise : 2 μVrms• High resolution : 5.5 digits• Intuitive operation by dials• 10 types of thermocouple and RTD Pt100• User defined temperature calibration• 3 RJC modes• Calibration by temperature value
Voltage, current generation
Range Source range Resolution
10 mV ±12.0000 mV 100 nV
100 mV ±120.000 mV 1 μV
1 V ±1.20000 V 10 μV
10 V ±12.0000 V 100 μV
30 V ±32.000 V 1 mV
1 mA ±1.20000 mA 10 nA
10 mA ±12.0000 mA 100 nA
30 mA ±32.000 mA 1 μA
100 mA ±120.000 mA 1 μA
RangeAccuracy (1 year)
± (ppm of setting + μV or μA)
Stability (1 hour)± (ppm of setting + μV or μA)
10 mV 60 + 4 20 + 3
100 mV 60 + 4 20 + 3
1 V 60 + 15 5 + 10
10 V 60 + 150 5 + 100
30 V 60 + 450 5 + 300
1 mA 80 + 0.04 5 + 0.015
10 mA 100 + 0.5 5 + 0.15
30 mA 100 + 1.5 10 + 0.9
100 mA 100 + 5 10 + 3
Calibration by temperature value2553A
2553A
120.0˚C
120˚C
Temperature generation for Thermocouple
Setting temperature : Accuracy for 1 year (±°C)
R S B J T
-50°C: 1.10 -50°C: 1.03 400°C: 1.00 -210°C: 0.25 -250°C: 0.72
0°C: 0.80 0°C: 0.75 600°C: 0.70 -100°C: 0.11 -200°C: 0.29
100°C: 0.55 100°C: 0.56 1000°C: 0.50 0°C: 0.08 -100°C: 0.16
600°C: 0.40 400°C: 0.47 1200°C: 0.44 1200°C: 0.15 100°C: 0.10
1600°C: 0.40 1600°C: 0.44 1820°C: 0.44 400°C: 0.09
1768°C: 0.45 1768°C: 0.51
E K N C A
-250°C: 0.50 -250°C: 0.94 -240°C: 1.00 0°C: 0.30 0°C: 0.34
-200°C: 0.20 -200°C: 0.30 -200°C: 0.44 200°C: 0.26 100°C: 0.29
-100°C: 0.10 -100°C: 0.15 -100°C: 0.21 600°C: 0.25 600°C: 0.28
0°C: 0.07 0°C: 0.11 0°C: 0.16 1000°C: 0.30 1600°C: 0.47
1000°C: 0.12 800°C: 0.15 800°C: 0.15 2000°C: 0.51 2500°C: 0.79
1300°C: 0.21 1300°C: 0.20 2315°C: 0.70
3 RJC modesINT: Detect temperature of output terminal as compensation valueEXT: Detect compensation value by sensor connected to RJC terminal
MAN: Input compensation value
Temperature generation for RTD
Type Source range ResolutionAccuracy (1 year)
Pt100 -200.0 to 850.0°C 0.1°C ±0.15°C
Resistance generation
Range Source range ResolutionAccuracy (1 year)
± (ppm of setting +Ω)
400 Ω 18.00 to 400.00 Ω 0.01 Ω 75 + 0.015
Interface : USB
: Ethernet
: GPIB
Warm-up time : Approx. 30 minutes
Operating environment : Temperature 5 to 40 °C
: Humidity 20 to 80% RH
Storage environment : Temperature -15 to 60 °C
: Humidity 20 to 80% RH
Operating Height : 2000 m or less
Operating Attitude : Horizon
Rated power supply voltage : 100 to 120 VAC/200 to 240 VAC
Allowable power supply voltage fluctuation range
: 90 to 132 VAC/180 to 264 VAC
Rated power supply frequency : 50/60 Hz
Allowable power supply frequency fluctuation range
: 48 to 63 Hz
Max. power cunsumption : 30 VA
Withstand voltage : Between power and case 1500 VAC 1 min.
Dimensions : 213(W) × 132(H) × 300(D) mm
Weight : Approx. 3 kg
Model Suffix code Description
2553A Precision DC Calibrator
–VA Version A
–UC Deg C
–UF Deg C and F
–D UL/CSA standard, PSE
–F VDE standard
–R AS standard
–Q BS standard
–H GB standard
–N NBR standard
41
Gen
erat
ors,
Sou
rces
,M
anom
eter
s et
c.
Generators, Sources, Manometers etc.
AC Standard Source with Improved Performance and Usability
AC Voltage Current Standard 2558A
Functions and Specifications
Features
Functions and Specification
2558A Model and Suffix Codes
2558A
Stability : ±(20 ppm of setting + 30 ppm of range)/hDistortion factor Voltage : 0.07% or less Current : 0.18% or lessFrequency range Internal : 50 / 60 / 400 Hz / VAR VAR: 40 to 1000 Hz (0.001 Hz resolution) External : EXT1/EXT2 (Use the terminals for synchronized operations) FREQUENCY METER : MIN/MAX 20 to 1000 Hz (0.001 Hz resolution) Sweep, output divider and deviation functions are used
for the frequency.Sweep Target : Voltage / Current / Frequency Speed : Approx. 8/16/32/64 sec. selectableOutput divider Target : Voltage / Current / Frequency Denominator range : m4 to 15 Numerator range : n0 to 15 (n ≤ m)Deviation Target : Voltage / Current / Frequency Variable range: ±20.00% Operation : Two dials
Resolution of the first dial: 0.2% of the main setting
Resolution of the second dial: 0.01% of the main setting
Deviation preset: OFF / 0 / 2% / 5%Output terminalType Voltage : Plug-in terminal (safety terminal) Current : Binding post Selectable LO terminal to earth or floating Max. floating voltage to earth: 12 VpkInterface : USB interface (for PC connection) : Ethernet : GP-IB interface (optional)Warm-up time : Approx. 30 minutesOperating environment Temperature : 5 to 40ºC Humidity : 20 to 80%RH (no condensation)Rated power supply voltage : 100 to 120 VAC / 200 to 240 VACRated power supply frequency : 50/60 HzMax. power consumption : 200 VAWeight : Approx. 20 kgDimensions : 426(W) × 132(H) × 400(D) mm
The wide output ranges of 1.00 mV to 1200.0 V AC and 1.00
mA to 60.00 A AC mean that the 2558A is the instrument
of choice for the cost effective calibration of AC analog
meters.
• Wide output range AC voltage : 1.00 mV to 1200.0 V AC current : 1.00 mA to 60.00 A• High accuracy AC voltage : 0.04% AC current : 0.05%• High output stability : ±50 ppm/h• Wide frequency range : 40 to 1000 Hz Accuracy : ±50 ppm• Intuitive operation with dials for setting each digit• Sweep function : 8/16/32/64 sec. (selectable)• Output divider function (Divided output of the main setting)• Direct readout of the deviation (Displays the deviation from the main
setting)
Output
Range Output Range Guaranteed Accuracy Range
100 mV 0 to 144.00 mV 1 to 120.00 mV
1 V 0 to 1.4400 V 0.01 to 1.2000 V
10 V 0 to 14.400 V 0.1 to 12.000 V
100 V 0 to 144.00 V 1 to 120.00 V
300 V 0 to 432.0 V 3 to 360.0 V
1000 V 0 to 1440.0 V 10 to 1200.0 V
100 mA 0 to 144.00 mA 1 to 120.00 mA
1 A 0 to 1.4400 A 0.01 to 1.2000 A
10 A 0 to 14.400 A 0.1 to 12.000 A
50 A 0 to 72.00 A 0.5 to 60.00 A
Accuracy (180 days) 1 to 10% output of range ±(% of range) Voltage 50/60 Hz : 0.013 40 to 400 Hz : 0.015 400 to 1000 Hz : 0.030 Current 50/60 Hz : 0.014 40 to 400 Hz : 0.016 400 to 1000 Hz : 0.032 10 to 120% output of range ±(% of setting + % of range) Voltage 50/60 Hz : 0.03 + 0.01 40 to 400 Hz : 0.05 + 0.01 400 to 1000 Hz : 0.10 + 0.02 Current 50/60 Hz : 0.04 + 0.01 40 to 400 Hz : 0.06 + 0.01 400 to 1000 Hz : 0.12 + 0.02
Model Suffix Code Description
2558A AC Voltage Current Standard
Power cord -D UL/CSA standard, PSE
-F VDE standard
-R AS standard
-Q BS standard
-H GB standard
-N NBR standard
Option /C1 GP-IB interface
42
Gen
erat
ors,
Sou
rces
,M
anom
eter
s et
c.
Generators, Sources, Manometers etc.
High-voltage and High-current Output and Intuitive Operation
Features
Main Specifications
Precision DC Calibrator 2560A
Model and suffix codes
Main Specifications
The 2560A can accurately and stably generate DC voltage of up to 1224 V
and DC current of up to 36.72 A. In addition to voltage and current meters,
the 2560A can calibrate thermometers and temperature controllers that use
thermocouples and RTDs.
• Wide output range DC voltage : ±1224 V DC current : −12.24 A to +36.72 A• High accuracy DC voltage : ±50 ppm (0.005%) DC current : ±70 ppm (0.007%)• High stability DC voltage : ±10 ppm (0.001%)/h DC current : ±20 ppm (0.002%)/h• High resolution : 5.5 digits, ±120,000 count display 6.5 digits, ±1,200,000 count display• Intuitive operability with dials for each digit• Sweep, output division, deviation, scale setting• Ten types of thermocouples, and RTD Pt100• User-defined temperature calibration, three RJC modes
Voltage and current generating parts
Range Output range Resolution
100 mV ±122.400 mV 1 μV
1 V ±1.22400 V 10 μV
10 V ±12.2400 V 100 μV
100 V ±122.400 V 1 mV
1000 V ±1224.00 V 10 mV
100 μA ±122.400 μA 1 nA
1 mA ±1.22400 mA 10 nA
10 mA ±12.2400 mA 100 nA
100 mA ±122.400 mA 1 μA
1 A ±1.22400 A 10 μA
10 A ±12.2400 A 100 μA
30 A 0 to +36.720 A 1 mA
RangeAccuracy (one year)
± (ppm of setting + V or A)
Stability (1 h)
± (ppm of setting + V or A)
100 mV 60 + 4 μV 20 + 3 μV
1 V 55 + 15 μV 5 + 5 μV
10 V 55 + 150 μV 5 + 50 μV
100 V 55 + 1.5 mV 5 + 500 μV
1000 V 55 + 15 mV 5 + 5 mV
100 μA 150 + 20 nA 50 + 5 nA
1 mA 70 + 30 nA 5 + 15 nA
10 mA 70 + 300 nA 5 + 150 nA
100 mA 90 + 3 μA 10 + 1.5 μA
1 A 350 + 70 μA 25 + 25 μA
10 A 380 + 1.2 mA 50 + 500 μA
30 A 540 + 1.8 mA 70 + 1.2 mA
Bulletin: 2560A-01EN
Temperature generation for thermocouples
Setting temperature: Accuracy for one year (±°C)
R S B J T
−50°C: 1.10 −50°C: 1.03 400°C: 1.00 −210°C: 0.25 −250°C: 0.72
0°C: 0.80 0°C: 0.75 600°C: 0.70 −100°C: 0.11 −200°C: 0.29
100°C: 0.55 100°C: 0.56 1000°C: 0.50 0°C: 0.08 −100°C: 0.16
600°C: 0.40 400°C: 0.47 1200°C: 0.44 1200°C: 0.15 100°C: 0.10
1600°C: 0.40 1600°C: 0.44 1820°C: 0.44 400°C: 0.09
1768°C: 0.45 1768°C: 0.51
E K N C A
−250°C: 0.50 −250°C: 0.94 −240°C: 1.00 0°C: 0.30 0°C: 0.34
−200°C: 0.20 −200°C: 0.30 −200°C: 0.44 200°C: 0.26 100°C: 0.29
−100°C: 0.10 −100°C: 0.15 −100°C: 0.21 600°C: 0.25 600°C: 0.28
0°C: 0.07 0°C: 0.11 0°C: 0.16 1000°C: 0.30 1600°C: 0.47
1000°C: 0.12 800°C: 0.15 800°C: 0.15 2000°C: 0.51 2500°C: 0.79
1300°C: 0.21 1300°C: 0.20 2315°C: 0.70
Three RJC modesINT: Uses a temperature measured at the output terminal as a compensation value.EXT: Uses a temperature detected by a sensor connected to the RJ sensor terminal as a compensation value.
MAN: Uses a value input manually as a compensation value.
Temperature generation for RTDs
Type Output range ResolutionAccuracy(one year)
Pt100 −200.0 to 850.0°C 0.1°C ±0.12°C
Resistance generation
Range Output range ResolutionAccuracy (one year)
± (ppm of setting + Ω)
400 Ω 1.00 to 400.00 Ω 0.01 Ω 75 + 0.005
Interface : USB interface (PC connection)
: Ethernet
: GP-IB
Warm-up time : Approx. 30 min
Operating environment : Temperature 5 to 40ºC
Humidity 20 to 80%RH
(no condensation)
Rated power supply voltage : 100 to 120 V AC/200 to 240 V AC
Rated power supply frequency : 50/60 Hz
Max. power consumption : Approx. 200 V A
Dimensions : 426 (W) × 177 (H) × 400 (D) mm
Weight : Approx. 13 kg
Model code Suffix code Description
2560A Precision DC Calibrator
–VA Version A
–UC Deg C
–UF Deg C and F
–D UL/CSA standard, PSE compliant
–F VDE standard
–R AS standard
–Q BS standard
–H GB standard
–N NBR standard
43
Gen
erat
ors,
Sou
rces
,M
anom
eter
s et
c.
Generators, Sources, Manometers etc.
Bring new value by the multiple display formats and high sampling speed
Features
Digital Multimeter DM7560
Model and suffix codes
Functions and Specifications
The DM7560 provides high sampling rates of up to
30 kS/s with high accuracy and provides all the basic
functions of a Digital Multimeter. With its capability to
monitor transitional voltage variations, it can be applied
to a wide range of applications.
• Multiple display formats• High speed data logging (Maximum 30 kS/s)• High capacity internal memory up to 100 k points• Offline browsing to provide trend and histogram analysis• Productivity improvement by varied interfaces
DC voltage (DCV) Range: 100 mV to 1000 V
DC current (DCI) Range: 1 mA to 3 A
AC voltage (ACV) Range: 100 mV to 750 V
AC current (ACI) Range: 1 A to 3 A
Resistance measurement (2 WΩ/4 WΩ) Range: 100 Ω to 100 MΩContinuity test (CONT) Resistance range: 1 kΩDiode Measuring current: Approx. 1 mA
Temperature measurement (TEMP, TC) Thermocouple type: R/K/T/J/E
Temperature measurement (TEMP, RTD) Resistance temperature
detector: Pt100, Jpt100
Frequency measurement (FREQ) Range: 3 Hz to 300 kHz
Advange points
Comprehensive observation by multiple display formats High-speed data logging
Model code Suffix code Description
DM7560 Digital Multimeter
Supply voltage -1 100 VAC, 50/60 Hz
-3 115 VAC, 50/60 Hz
-6 220 VAC, 50/60 Hz
-8 240 VAC, 50/60 Hz
Power cord -D UL/CSA standard, PSE compliant
-F VDE Standard
-R AS Standard
-Q BS Standard
-H GB Standard
-N NBR Standard
Options /C1 GP-IB Interface*
/C2 LAN & RS-232 Interface*
/CMP DIO Interface
* Only one can be selected.
-1.5
-1
-0.5
0
0.5
1
1.5
-1.5
-1
-0.5
0
0.5
1
1.5
Fast signal change can be measured exactly with high sampling rate.
The case of 10 ms pulse width, 2 Vpp measurementwith DC voltage measuring function.
Sample of 1 kS/s
Sample of 30 kS/s
Annunciator
Indicates the status of the instrument
status by icons.
Secondary display (examples)
Analog meter display
Statistics display
LIMIT judgment display
Primary display (examples)
Trend display (Plots time domain variation)
Histogram display (Plots distribution)
Arc scale meter display (Shows values
intuitively)
44
Gen
erat
ors,
Sou
rces
,M
anom
eter
s et
c.
Generators, Sources, Manometers etc.
Temperature Measuring Instrument 7563
7563Digital Thermometer, 6.5 Digits
• Thermometer has a 6.5-digits display Twelve types of TC’s and four types of RTD’s• Basic accuracy in temperature
measurement: 0.006% (TC)• Basic accuracy in DCV measurement: 0.0045% (2000 mV range)• Basic accuracy in resistance measurement: 0.006% (2000 Ω range)• Number of sampling times: up to 100 times/s (4.5 digits)
7563 Specifications
Maximum display: ±1999999Resolution: Voltage 100 nV Resistance 100 μΩ Thermocouple 0.1°C RTD 0.01°CReference junction compensation accuracy: ±0.2°CVarious computation functionsSoftware calibration functionMemory function• Internal memory up to 1000 data items• IC memory up to 8000 data itemsCommunication function: GP-IBAnalog output (optional): code /DA specifiedPower consumption: 20 VAExternal dimensions: 213 (W) × 88 (H) × 350 (D) mmWeight: approx. 3 kg
Precision Digital Thermometer
Digital Resistance Meter 7556
7556
• High-speed measurement (2.8 ms)• High accuracy: ±(0.006% of reading + 3 digits)• High resolution: 5.5 digits• Wide range: 1 Ω range to 100 MΩ range• Full remote control through serial (RS-232) or GP-IB interface• Software-based calibration function• Advanced contact check function
7556 Specifications
Range: 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ, 1 MΩ, 10 MΩ, 100 MΩ
Resolution: Deviation display 755601: -99.99% to 19.99% or -99.9% to 199.9% (selectable) 755611: -99.999% to 19.999% or -99.99 to 199.99% (selectable) Absolute value display 755601: 100 μΩ (at 1 Ω range) 755611: 10 μΩ (at 1 Ω range)Measurement time: Normal mode: 60 Hz power supply: 19.9 ms 50 Hz power supply: 23.2 ms Fast mode: 5.7 ms High-speed mode: 2.8 msAccuracy (at 1 kΩ range, 23±5°C in normal mode) 755601: ±(0.015% of reading + 1 digit) 755611: ±(0.006% of reading + 3 digits)Contact check function Check level: 1 Ω to 30 Ω (Selectable) Execute checks before or after measurement (selectable) Check current: 50 mA Contact check error message with display panel and handler interface Measured current abnormality detection function (Detect measured current abnormality caused by a
contact error)Comparator function (both Hi and Lo) Deviation setting range 755601: -9.99% to 9.99% or -99.9% to 99.9% (selectable) 755611: -9.999% to 9.999% or -99.99% to 99.99% (selectable) Absolute value setting range 755601: 0.0000 Ω to 1.2000 Ω 755611: 0.00000 Ω to 1.20000 Ω
The 7556 is designed to be mounted on a taping machine.
* When you use the 7556 for any purpose other than a production line, you need to be careful.
Please read the specifications carefully.
High-Speed Digital Resistance Meter for Production Line of Fixed Chip Resistors
45
Gen
erat
ors,
Sou
rces
,M
anom
eter
s et
c.
Generators, Sources, Manometers etc.
Functions and Specifications
FG410/FG420 Models and Suffix Codes
Related Software
Easily Generate Basic, Application Specific and Arbitrary Waveform
Features
The FG400 Arbitrary/Function Generator provides a wide
variety of waveforms as standard and generates signals
simply and easily. There are one channel (FG410) and
two channel (FG420) models. As the output channels are
isolated, an FG400 can also be used in the development
of floating circuits. (up to 42 V)
• 0.01 μHz to 30 MHz output (sine wave)• 20 Vp-p output/open, 10 Vp-p output/50 Ω• Arbitrary waveform generation function• 3.5-inch color display• Up to 6 units (12 channels) can be synchronized• A variety of sweeps, modulations and functions• Parameter-variable waveforms
Model Suffix code Description
FG410 Arbitrary /Function Generator, 1-Channel Model
FG420 Arbitrary /Function Generator. 2-Channel Model
Power cord -D UL/CSA standard, PSE
-F VDE standard
-R AS standard
-Q BS standard
-H GB standard
-N NBR standard
FG420
This software allows you to display the waveforms and measurement results on a PC for the data measured with Yokogawa’s DLM/DL/SL series. It allows you to clip part of a waveform and generate an arbitrary waveform with the FG400.
This software supports the arbitrary waveform function of the FG400. It allows you to edit waveforms and transfer data to the FG400. It also makes it easy to work on a pre-installed waveform to generate an arbitrary waveform.
This software supports the sequence function of the FG400 that outputs different waveforms sequentially. It controls the edit, transfer, and execution of sequence data. Complex programs can also be created easily.
XviewerLITE Arbitrary Waveform Editor Sequence Editor
• Number of channels FG410: 1-channel model FG420: 2-channel model• Output waveforms Sine, square, pulse, ramp, DC, parameter-variable
waveform (25 types), noise (Gaussian distribution), arbitrary waveform
• Oscillation modes Continuous, modulation, sweep, burst, sequence• Frequency Sine 0.01 μHz to 30 MHz Square/pulse 0.01 μHz to 15 MHz Ramp/parameter-variable waveform 0.01 μHz to 5 MHz• Arbitrary waveform Waveform length 4 K to 512 K words or 2 to
10,000 control points• Modulation type FM, FSK, PM, PSK, AM, DC offset, PWM• Sweep type Frequency, phase, amplitude, DC offset, duty• Synchronization Sync operation is possible. Up to 6 units can be of multiple units connected with BNC cables in the form of master/ slave connections, using the frequency reference output and external 10 MHz frequency reference input• Power supply AC 100 V to 230 V ± 10% (250 V max.) 50 Hz/60 Hz ± 2 Hz• Power consumption FG410 50 VA or less FG420 75 VA or less• Weight Approx. 2.1 kg• Dimensions 216 (W) × 88 (H) × 332 (D) mm
Arbitrary/Function Generator FG400 Series
46
Gen
erat
ors,
Sou
rces
,M
anom
eter
s et
c.
Generators, Sources, Manometers etc.
Pressure Standard MC100
MC100Pneumatic Pressure Standard
• High accuracy: ±0.05% of full scale• Output ranges and resolution 0 to 200 kPa (resolution 0.01 kPa) 0 to 25 kPa (resolution 0.001 kPa)• Functions useful for instrument calibration Divider output, auto-step output, and sweep
output• Excellent temperature coefficient Zero point: ±0.003% of full scale/°C Span: ±0.002% of full scale/°C
MC100 Series Specifications
• Supply pressure 0 to 200 kPa range model: 280 kPa ±20 kPa 0 to 25 kPa range model: 50 kPa ±10 kPa• Accuracy ±0.05% of full scale (at 23°C ±3°C)• Output noise: ±0.02% of full scale• Effect of mounting orientation Forward/backward incline of 90° 0 to 200 kPa range model: ±0.01% of
full scale 0 to 25 kPa range model:
Pneumatic Pressure Standard
±0.1% of full scale Sideways incline of 30° 0 to 200 kPa range model: ±0.2% of
full scale 0 to 25 kPa range model: ±2.5% of
full scale• Pressure display units (selectable): kPa, kgf/cm2, mmH2O, mmHg kPa, psi, inH2O, inHg• External dimensions: 213 (W) × 132 (H) × 400 (D) mm• Weight: approx. 9.5 kg
47
Gen
erat
ors,
Sou
rces
,M
anom
eter
s et
c.
Generators, Sources, Manometers etc.
Manometers MT210/MT210F/MT220/MT10
MT210FDigital Manometer
• High accuracy: ±(0.01% of reading + 3 digits) (130 kPa range gauge model)
• Select from three measurement modes: normal speed, medium speed, and high speed
• D/A conversion output, comparator output, and external trigger input (optional)
• Both gases and liquids measurable• External attachable battery pack (optional)
MT210F Series Specifications
• Measuring range (gauge pressure: positive) 0 to 10 kPa, 130 kPa, 700 kPa and 3000 kPa Measuring range (gauge pressure: negative) -80 to 0 kPa, -10 to 0 kPa• Measuring range (absolute pressure) 0 to 130 kPa abs• Accuracy (for 0 to 10 kPa range model) ±(0.01% of reading + 0.015% of full
scale) (at positive pressure)• Response time (0 to 130 kPa range model,
at high speed mode) 50 msec max.• Readout update interval (at medium and
high speed mode) 100 msec• Resolution 0 to 10 kPa range model: 0.0001 kPa 0 to 130 kPa range model: 0.001 kPa 0 to 700 kPa range model: 0.01 kPa 0 to 3000 kPa range model: 0.01 kPa• Maximum allowable input (for gauge
pressure positive) 0 to 10 kPa range model: 500 kPa gauge 0 to 130 kPa range model: 500 kPa gauge 0 to 700 kPa range model: 3000 kPa gauge 0 to 3000 kPa range model: 4500 kPa gauge• Pressure display units (selectable): psi, inH2O, inHg, kPa, kgf/cm2, mmH2O, mmHg• External dimensions: 213 (W) × 132 (H) × 350 (D) mm• Weight Approx. 6.5 kg (0 to 130 kPa range model)
Fast Response Digital Manometer
MT210Digital Manometer
• High accuracy: ±(0.01% of reading + 3 digits) (130 kPa range gauge model)
• A wide range pressures, from a low differential pressure of 1 kPa to a high gauge pressure of 3000 kPa, and absolute pressure of 130 kPa
• D/A conversion output, comparator output, and external trigger input (optional)
• Both gases and liquids measurable• External attachable battery pack (optional)
MT210 Series Specifications
• Measuring range (gauge pressure: positive) 0 to 10 kPa, 130 kPa, 700 kPa and 3000 kPa Measuring range (gauge pressure: negative) -80 to 0 kPa, -10 to 0 kPa• Measuring range (absolute pressure) 0 to 130 kPa abs• Measuring range (differential pressure) 0 to 1 kPa, 10 kPa, 130 kPa and 700 kPa• Accuracy (for 0 to 10 kPa range model) ±(0.01% of reading + 0.015% of full
scale) (at positive pressure)• Resolution 0 to 1 kPa range model: 0.00001 kPa 0 to 10 kPa range model: 0.0001 kPa 0 to 130 kPa range model: 0.001 kPa 0 to 700 kPa range model: 0.01 kPa 0 to 3000 kPa range model: 0.01 kPa• Maximum allowable input (for gauge
pressure positive) 0 to 10 kPa range model: 500 kPa gauge 0 to 130 kPa range model: 500 kPa gauge 0 to 700 kPa range model: 3000 kPa gauge 0 to 3000 kPa range model: 4500 kPa gauge• Pressure display units (selectable): psi, inH2O, inHg, kPa, kgf/cm2, mmH2O,
mmHg• External dimensions: 213 (W) × 132 (H) × 350 (D) mm• Weight Approx. 6.5 kg (0 to 130 kPa range model)
Precision Digital Manometer
Digital Manometer For Efficient Field Calibration Handheld Digital Manometer
MT10Mini-Manometer
• Compact and lightweight (approx. 700 g), battery-operated
• High reliability (silicon resonant sensor adopted)
• Accuracy: ±(0.04% of rdg + 0.03% of FS) for 130 kPa model
• Three models for 130 kPa, 700 kPa, and 3000 kPa (gauge pressure)
• Data hold function• RS-232-C interface• Comes with carrying case
MT220Digital Manometer
• The de facto standard of field celibrators for pressure and ditferential pressure transmitters
• High accuracy: ±(0.01% of reading + 3 digits) (130 kPa range gauge model)
• DCV/DCA measurement function (DMM function)
• 24 VDC power supply for driving the transmitter
• % display, error display, and measured data memory
• D/A conversion output, comparator output, and external trigger input (optional)
• Both gases and liquids measurable• External attachable battery pack (optional)
MT10 Series Specifications
• Type of pressure: gauge• Three measuring ranges 0 to 130 kPa, 0 to 700 kPa, and 0 to 3000 kPa• Measurement display range: -2.5 to 110% of FS• Accuracy: 0 to 130 kPa range model ±(0.04% of rdg + 0.03% of FS) 0 to 700 kPa and 0 to 3000 kPa range
models ±0.1% of FS• Resolution 0 to 130 kPa range model: 0.01 kPa 0 to 700 kPa range model: 0.1 kPa 0 to 3000 kPa range model: 1 kPa• Maximum allowable input 0 to 130 kPa range model: 500 kPa 0 to 700 kPa range model: 1000 kPa 0 to 3000 kPa range model: 4500 kPa• Effect of temperature Zero: ±0.02% of FS/10°C or less Span: ±0.02% of FS/10°C or less• Pressure display units (specified at shipment) kPa, kgf/cm2, mmH2O, mmHg, Psi, inH2O, inHg• External dimensions: Approx. 72 (W) × 174 (H) × 60 (D) mm (excluding input connections)• Weight: Approx. 700 g (including battery)
MT220 Series Specifications
• Measuring range (gauge pressure: positive) 0 to 10 kPa, 130 kPa, 700 kPa and 3000 kPa Measuring range (gauge pressure: negative) -80 to 0 kPa, -10 to 0 kPa• Measuring range (absolute pressure) 0 to 130 kPa abs• Accuracy (for 0 to 10 kPa range model) ±(0.01% of reading + 0.015% of full
scale) (at positive pressure)• Resolution 0 to 10 kPa range model: 0.0001 kPa 0 to 130 kPa range model: 0.001 kPa 0 to 700 kPa range model: 0.01 kPa 0 to 3000 kPa range model: 0.01 kPa• Maximum allowable input (for gauge
pressure positive) 0 to 10 kPa range model: 500 kPa gauge 0 to 130 kPa range model: 500 kPa gauge 0 to 700 kPa range model: 3000 kPa gauge 0 to 3000 kPa range model: 4500 kPa gauge• Pressure display units (selectable): psi, inH2O, inHg, kPa, kgf/cm2, mmH2O, mmHg• Measurement range of DCV/DCA
measurement function 0 to ±5.25 V 0 to ±21 mA• Accuracy of DCV/DCA measurement
function (6 months after calibration) ±(0.05% of reading + 3 digits)• 24 VDC output 24 ± 1 VDC, 30 mA max.• External dimensions: 213 (W) × 132 (H) × 350 (D) mm• Weight Approx. 7.0 kg (0 to 130 kPa range model)
48
Optic
al M
easu
ring
Inst
rum
ents
Optical Measuring Instruments
High Performance Optical Spectrum Analyzers Meeting Measurement Needs in a Broad Range of Applications
Optical Spectrum Analyzer AQ6370 Series
AQ6370 Series of Optical Spectrum Analyzers Common Specifications
• Best-in-class optical performance
· High wavelength resolution and high dynamic range
· High sensitivity
· Free-space optical input
• Excellent measurement throughput
· High-speed spectrum measurement
· High-speed remote interface
· High resolution and wide bandwidth batch measurement
• More user-friendly
· USB interface available
For mouse, keyboard, and external storage devices such as a memory
device and hard disc drive (HDD).
· Trace zooming function
· More than 10 waveform analysis functions available
• Support for creating an automatic measurement system
· GP-IB, RS-232C, and Ethernet interfaces available
· Support for the remote commands and formats of the AQ6317 series
· Macro programming function available
• Wavelength calibration reference light source or alignment light
source available
• AQ6370 Viewer emulation and remote control software (option)
Three Models Converting a Wide Wavelength from 350 nm to 3400 nm
AQ6370D (600 to 1700 nm)
Standard model optimized to the wavelengths often used in telecommunication
applications
AQ6373B (350 to 1200 nm)
Model for short-wavelength including visible light (VIS)
AQ6375B (1200 to 2400 nm)/AQ6376 (1500 to 3400 nm)
Model for emerging applications in exNIR+MWIR regions
Features
Short Wavelength
Long Wavelength
400 600 1000 1200 1500 1700 2000 2400 3400wavelength
(nm)
Main Optical Applications and Wavelength Bands Used
Visible Light Range
AQ6373B AQ6376
Medical Treatment – Biology – Information & Communication – Environmental Analysis – Sensing – Material Processing, etc.
AQ6375B
AQ6370D
Optical Applications
Today, optical technology is used in a
wide variety of applications, which include
biomedical application and environmental
measurement, as well as information
and communication, where demand for
broadband connectivity is growing rapidly,
driven by the popularity of the Internet, IP
telephony, and video streaming. Yokogawa’s
optical spectrum measurement technology
contributes to the development of such
optical applications.
Items Specifications
Electrical interface GP-IB, RS-232, Ethernet, USB, SVGA output, Analog output port, Trigger input port, Trigger output port
Remote control *1 GP-IB, RS-232, Ethernet (TCP/IP), AQ6317 series compatible commands (IEEE488.1) and IEEE488.2
Purge gas input/ou tput terminals *3 Outer diameter 1/4 inch, nylon tube
Data storageInternal storage: 512 MBytes, Internal memory: 64 Traces, 64 programs, 3 template lines, External storage: USB storage (memory/HDD), FAT32 format File types: CSV (text), Binary, BMP, TIFF
Display *2 10.4-inch color LCD (Resolution: 800 × 600)
Dimensions Approx. 426 (W) × 221 (H) × 459 (D) mm (Excluding protector and handle)
Mass AQ6370D/AQ6373B: Approx. 19 kg, AQ6375B/AQ6376: Approx. 23 kg
Power requirements 100 to 240 V AC, 50/60 Hz, approx. 100 VA
Environmental conditionsPerformance guarantee temperature: +18 to +28°C, Operating temperature: +5 to +35°C, Storage temperature: −10 to +50°C, Humidity: 20 to 80%RH (no condensation)
RoHS EN50581
Recommended calibration period 1 year
*1: Some AQ6317 series commands may not be compatible due to changes in specifications or functions. *2: Liquid crystal display may include a few defective pixels (within 0.002% with respect to the total number of pixels including RGB).
There may be a few ixels on the liquid crystal display that do not emit all the time or remains ON all the time. These are not malfunctions. *3: AQ6375B and AQ6376 *4: With built-in calibration light source
Environmental Measurement ApplicationInformation & Communication ApplicationBiomedical Application
Example of a Configuration of a Scanning Confocal Microscope System
Cell
Fluorescence from a cell
Camera
Laser
Fluorescence
Microscope
Model CSU10
Confocal Scanner Unit
Z-axis Drive
Image Monitor
Image Processing
Unit
High Performance Filter
TX Terminal
λ1
λ2
λ3
λ4
λ5
λn
λ1
λ2
λ3
λ4
λ5
λ6
Optical AMP
OADM
RX Terminal
Optical Fiber
DEMUXMUX
100 km~ 100 km~ 100 km~
DWDM Transmission System
Optical AMP
OADM
Amplified
Example of a Configuration of a Dense Wavelength Division Multiplexing (DWDM) Optical Communication System
Example of a Configuration of Simultaneous Multi-Wavelength Measurement of Gases Using the CDRS Technique
Detecting Gases Using Gas-SpecificLight Absorption Characteristics
CRDS Optical
Coupler
Laser λ1
Circulator
Fiber Grating
WDM
Coupler
Fiber Loop
λ1
λ2
Laser λ2
OpticalFiber
OpticalFiber
OpticalFiber
• Evaluating the performance of high performance filers for a visible light laser and fluorescence extraction
• Evaluating the performance of optical components, such as a laser, optical multiplexer, optical demultiplexer and optical amplifier, as well as the system as a whole
• Evaluating the performance of optical components such as a laser and grating
• Evaluating the light absorption characteristics of gases
49
Optic
al M
easu
ring
Inst
rum
ents
Optical Measuring Instruments
Redefining Optical Spectrum Measurement Excellence
• World Class Optical Performance & Flexibility High wavelength accuracy: ±0.01 nm High close-in dynamic range: 78 dB typ. Single and multimode fiber test capability (up to GI 62.5/125 μm)• Improved Measurement Throughput Double-speed mode Fast measurement and fast data transfer• Enhanced User Friendliness USB for Mouse, keyboard, and external storage devices Bright 10.4” LCD Trace zoom capability Various built-in analysis functions• Expedites Development of Automated Test Systems Supports GP-IB, RS-232C, and Ethernet interfaces Compatible with SCPI and supports AQ6317 series remote commands Built-in simple macro programming function• Includes Wavelength Calibration Source (Optional)• AQ6370 Viewer: Emulation/Remote control software (Optional)
Features
Example of the dynamic range
Peak±1.0 nm, Resolution setting 0.05 nm, High dynamic mode: ON, High performance model
DWDM signal measurement
DWDM channels allocated at 50 GHz spac-ing can be measured and analyzed.
World-class optical performance Enhanced User Friendliness
click
drag
Mouse
Keyboard
Memory
HDD
USB interface
Supports mouse, keyboard, and external storage devices.
Trace zoom function
Enlarges a designated area
78dB
Optical Spectrum Analyzer AQ6370D
Enhanced functions
• Data logging function The Data Logging function records analysis results such as WDM
analysis (OSNR, optical signal/noise ratio), distributed feedback laser diode (DFB-LD) analysis, and multi-peak measurements at up to 10,000 points per channel with time stamps. Recorded data can be displayed in table and graphical forms.
• Advanced marker function The Advanced Marker function adds markers to obtain the power
density and the integrated power of a designated spectrum.• Gate sampling function The Gate Sampling function facilitates the recirculating loop testing of
optical transmission systems. • Resolution calibration function The Resolution Calibration function is used to calibrate the noise
equivalent bandwidth with an external light source.
Data Logging display Advanced marker display
Main Specifications
Items Specifications
Spec-code Standard (-10) High performance (-20)
Wavelength range *1 600 to 1700 nm
Span *1 0.1 nm to 1100 nm (Full span), and 0 nm
Wavelength accuracy *1, *2, *5 ±0.02 nm (1520 to 1620 nm) ±0.01 nm (1520 to 1580 nm), ±0.02 nm (1580 to 1620 nm)
Wavelength resolution setting *1, *2 0.02, 0.05, 0.1, 0.2, 0.5, 1 and 2 nm
Number of sampling 101 to 50001, AUTO
Level sensitivity setting NORM_HOLD, NORM_AUTO, NORMAL, MID, HIGH1, HIGH2 and HIGH3
High dynamic mode SWITCH (Sensitivity: MID, HIGH1-3)
Level sensitivity *2, *3, *4, *7 −90 dBm (1300 to 1620 nm), −85 dBm (1000 to 1300 nm), −60 dBm (600 to 1000 nm) (Sensitivity: HIGH3)
Maximum input power *2, *3 +20 dBm (Per channel, full range)
Level accuracy *2, *3, *4, *6 ±0.4 dB (1310/1550 nm, Input level: −20 dBm, Sensitivity: MID, HIGH1-3)
Dynamic range *1, *2, *8 Resolution: 0.02 nm 55 dB (Peak ±0.2 nm), 37 dB (Peak ±0.1 nm) 58 dB (Peak ±0.2 nm, Typ. 60 dB), 45 dB (Peak ±0.1 nm, Typ. 50 dB)
Resolution: 0.1 nm 57 dB (Peak ±0.4 nm), 40 dB (Peak ±0.2 nm) 60 dB (Peak ±0.4 nm, Typ. 67 dB), 45 dB (Peak ±0.2 nm, Typ. 50 dB)
Stray-light suppression ratio *7, *10 73 dB 76 dB (Typ. 80 dB)
Applicable fiber SM (9.5/125 μm), GI (50/125 μm, 62.5/125 μm)
Optical connector Optical input: AQ9447 ( ) Connector adapter (option) required.Calibration output: AQ9441 ( ) Universal adapter (option) required. ( ) Connector type FC or SC
Built-in calibration light source *11 Wavelength reference source (For optical alignment and wavelength calibration)
Sweep time *1, *7, *9 NORM_AUTO: 0.2 sec, NORMAL: 1 sec, MID: 2 sec, HIGH1: 5 sec, HIGH2: 20 sec, HIGH3: 75 sec
Warm-up time Minimum 1 hour (After warming up, optical alignment adjustments required.)
*1: Horizontal scale: Wavelength display mode.
*2: With 9.5/125 μm single mode fiber with a PC type connector, after 1 hour of warm-up, after optical alignment
with built-in reference light source or a single longitudinal mode laser (wavelength 1520 to 1560 nm, peak
level ≥ −20 dBm, level stability ≤ 0.1 dBpp, and wavelength stability ≤ ±0.01 nm).
*3: Vertical scale: Absolute power display mode, Resolution setting: ≥ 0.05 nm, Resolution correction: OFF.
*4: With 9.5/125 μm single mode fiber (B1.1 type defined on IEC60793-2, PC polished, mode field diameter: 9.5
μm, NA: 0.104 to 0.107).
*5: After wavelength calibration with built-in reference light source or a single longitudinal mode laser (wavelength
1520 to 1560 nm, peak level ≥ −20 dBm and absolute wavelength accuracy ±0.003 nm).
*6: Temperature condition changes to 23 ±3°C at 0.05 nm resolution setting.
*7: High dynamic mode: OFF, Pulse light measurement mode: OFF, Resolution correction: OFF.
*8: 1523 nm, High dynamic mode: SWITCH, Resolution correction: OFF
*9: Span: ≤ 100 nm, Number of sampling: 1001, Average number: 1.
*10: With He-Ne laser (1523 nm), 0.1 nm resolution setting, 1520 nm to 1620 nm except for peak wavelength ±2 nm.
*11: Option.
“Typical” or “typ.” in this document means “Typical value”, which is for reference, not guaranteed specification.
50
Optic
al M
easu
ring
Inst
rum
ents
Optical Measuring Instruments
The OSA for emerging applications in exNIR + MWIR regions
• Unparalleled Performance
Wavelength range: 1200 to 2400 nm (AQ6375B)
1500 to 3400 nm (AQ6376)
Wavelength resolution setting: 50 pm to 2 nm (AQ6375B)
0.1 to 2 nm (AQ6376)
Wide measurement level range: -70 to +20 dBm (AQ6375B)
-65 to +13 dBm (AQ6376)
Close-in dynamic range: 55 dB
• Greater Efficiency
High speed measurement
Fast command processing and data transfer
• Support Multimode Fiber
Free-space optical input
• Intuitive Easy Operation
Mouse & keyboard operation
Trace zoom function
• Easy Calibration
Built-in calibrator
• AQ6375&76 Viewer: Emulation/Remote control software (Optional)
Features
2010 nm DFB-LD with AQ6375B(Res: 0.050 nm, Span: 20 nm)
3270 nm DFB-LD with AQ6376(Res: 0.1 nm, Span: 20 nm)
Main specifications
Unparalleled Optical Performance
Items Specifications
Model AQ6375B AQ6376
Wavelength range *1 1200 to 2400 nm 1500 to 3400 nm
Span *1 0.5 nm to 1200 nm (Full span), 0 nm 0.5 nm to 1900 nm (Full span), 0 nm
Wavelength accuracy *1,*2,*5 ±0.05 nm (1520 to 1580 nm),
±0.10 nm (1580 to 1620 nm),
±0.50 nm (Full range)
±0.50 nm (Full range)
Wavelength repeatability *1,*2 ±0.015 nm (1 min.)
Wavelength resolution setting *1,*2 0.05, 0.1, 0.2, 0.5, 1 and 2 nm 0.1, 0.2, 0.5, 1 and 2 nm
Minimum sampling resolution *1 0.002 nm 0.003 nm
Number of sampling 101 to 50001, AUTO
Level sensitivity setting NORM_HOLD, NORM_AUTO, NORMAL, MID, HIGH1, HIGH2 and HIGH3 (Only High dynamic mode (/CHOP) in HIGH1-3)
Level sensitivity *2,*3,*6 −70 dBm (1800 to 2200 nm),
−67 dBm (1500 to 1800 nm, 2200 to 2400 nm),
−62 dBm (1300 to 1500 nm) (Sensitivity: HIGH3)*4
−65 dBm (1500 to 2200 nm),
−55 dBm (2200 to 3200 nm),
−50 dBm (3200 to 3400 nm) (Sensitivity: HIGH3)
Maximum input power *2,*3 +20 dBm (Per channel, full wavelength range) +13 dBm (Per channel, full wavelength range)
Maximum safe input power *2,*3 +25 dBm (Total input power) +20 dBm (Total input power)
Level accuracy *2,*3,*4,*8 ±1.0 dB (1550 nm, input level: −20 dBm, Sensitivity: MID, HIGH1-3) ±1.0 dB (1550 nm, input level: −20 dBm, Sensitivity: HIGH1-3)
Level linearity *2,*3 ±0.05 dB (Input level: −30 to +10 dBm, Sensitivity: HIGH1-3) ±0.2 dB (Input level: −30 to +10 dBm, Sensitivity: HIGH1-3)
Polarization dependence *2,*3,*8 ±0.1 dB (1550 nm) —
Dynamic range *1,*2 45 dB (Peak ±0.4 nm, Resolution: 0.05 nm),
55 dB (Peak ±0.8 nm, Resolution: 0.05 nm)
(1523 nm, Sensitivity: HIGH1-3)
40 dB (Peak ±1 nm, Resolution: 0.1 nm),
55 dB (Peak ±2 nm, Resolution: 0.1 nm)
(1523 nm, Sensitivity: HIGH1-3)
Applicable fiber SM (9.5/125 μm), GI (50/125 μm, 62.5/125 μm)
Optical connector Optical input: AQ9447 ( ) Connector adapter (option) required.
Calibration output: AQ9441 ( ) Universal adapter (option) required.
( ) Connector type FC or SC
Built-in calibration light source Wavelength reference source (For optical alignment and wavelength calibration)
Sweep time *1,*6,*7 NORM_AUTO: 0.5 sec, NORMAL: 1 sec, MID: 2 sec, HIGH1: 20 sec
Warm-up time Minimum 1 hour (After warming up, optical alignment adjustment with built-in light source required.)
*1: Horizontal scale: Wavelength display mode.
*2: With 9.5/125 μm single mode fiber, after 2 hours of warm-up, after optical alignment with built-in reference light source, when the purge gas is not used.
*3: Vertical scale: Absolute power display mode, Resolution setting: ≥ 0.1 nm (AQ6375B)/ ≥ 0.2 nm (AQ6376).
*4: With 9.5/125 μm single mode fiber (B1.1 type defined on IEC60793-2, PC polished, mode field diameter: 9.5 μm, NA: 0.104 to 0.107).
*5: After wavelength calibration with built-in reference light source, Sampling resolution: ≤ 0.003 nm (AQ6375B)/AUTO (AQ6376), Sensitivity: MID, HIGH1-3
*6: Pulse light measurement mode: OFF.
*7: Span: ≤ 100 nm (The AQ6376 excluding 2200 to 2220 nm), Number of sampling: 1001, Average number: 1.
*8: Temperature condition changes to 23 ±3°C at 0.1 nm resolution setting (AQ6375B only).
Measurement Example
Optical Spectrum Analyzer AQ6375B/AQ6376
SMSR44.96dB
3270.35nmSMSR56.21dB
2010.12nm
51
Optic
al M
easu
ring
Inst
rum
ents
Optical Measuring Instruments
Optical Spectrum Analyzer AQ6373B
Short Wavelength OSA 350 - 1200 nm
Applications
Main Specifications
Item Specifications
Wavelength range *1 350 to 1200 nm
Span *1 0.5 nm to 850 nm (full span), and 0 nm
Wavelength accuracy *1 ± 0.05 nm (633 nm), ± 0.20 nm (400 to 1100 nm) (after wavelength calibration with 633 nm He-Ne laser)
Wavelength resolution setting *1, *2 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10 nm (full range), and 0.01 nm (400 to 470 nm)
Minimum sampling resolution *1 0.001 nm
Number of sampling points 101 to 50001, AUTO
Level sensitivity setting NORM_HOLD, NORM_AUTO, NORMAL, MID, HIGH1, HIGH2 and HIGH3
High dynamic mode SWITCH (sensitivity setting: MID, HIGH1 to 3)
Level sensitivity *3 -80 dBm (500 to 1000 nm), -60 dBm (400 to 500 nm, 1000 to 1100 nm) (Typical, Resolution setting: ≥ 0.2 nm, Averaging: 10 times, Sensitivity: HIGH3)
Maximum safe input power *3 + 20 dBm (550 to 1100 nm), + 10 dBm (400 to 550 nm) (total input power)
Level accuracy *2 ± 1.0 dB (850 nm, Input level: -20 dBm, Resolution: ≥ 0.2 nm, Sensitivity: MID, HIGH1 to 3, SMF [MFD5 μm@850 nm, NA0.14]
Level linearity *3 ± 0.2 dB (Input level: -40 to 0 dBm, Sensitivity: HIGH1-3)
Dynamic range *1 60 dB (Peak ± 0.5 nm, Resolution: 0.02 nm, 633 nm, Sensitivity: HIGH1 to 3)
Applicable fiber SM, GI (50/125 μm, 62.5/125 μm), Large core fiber (up to 800 μm)
Optical connector FC type (optical input and calibration light source output)
Built-in calibration light source Optical alignment light source (not equipped with wavelength reference light source.)
Sweep time *1, *4 NORM_ AUTO: 0.5 sec, NORMAL: 1 sec, MID: 2 sec, HIGH1: 5 sec, HIGH2: 20 sec, HIGH3: 75 sec
Warm-up time Minimum 1 hour (after warming up, optical alignment adjustment with built-in light source is required.)
Performance and functions can be limited by type of used fiber. The specifications are only guaranteed when a single mode fiber in which light travels in single mode at the measured wavelength is used. In the case in which the measured
wavelength is less than the cut-off wavelength of the used fiber, or a multimode fiber is used, a measured spectrum may be inaccurate due to speckle noise. Please be careful especially when measuring high coherency sources like gas laser
and laser diode.
*1: Horizontal scale: Wavelength display mode.
*2: Actual wavelength resolution varies according to the measured wavelength. Actual resolution at the 10 nm resolution setting is about 8 nm at most.
*3: Vertical scale: Absolute power display mode.
*4: High dynamic mode: OFF, Pulse light measurement mode: OFF, Number of sampling points: 1001, Average number: 1, Span: ≤ 100 nm excluding 450 to 470 nm and 690 to 700 nm.
• Wavelength accuracy: ±0.05 nm
• Wavelength resolution setting: 0.02 to 10 nm
(Settable to 0.01 nm at 400 to 470 nm)
• Max. safe input power: +20 dBm
• Level sensitivity: -80 dBm
• Dynamic range: ≥60 dB
• Single-mode, multimode, and
large-core fibers
• Built-in optical alignment source
• Automatic wavelength calibration
with an external source
• Data logging function
• Built-in color analysis function
for VIS
Active optical device (semiconductor laser, fiber laser, LED)
Passive active device (filter, FBG, special optical fiber)
Support for the development of optical devices
• Medical and biological applications (medical laser treatment, DNA
analysis, laser microscope)
• Industrial equipment (laser processing, laser marking)
• Home electronics (laser projector, next-generation optical disc, LED
products)
• Measurement (LIDAR, interferometer)
• Communication (plastic optical fiber (POF) communication)
Visible LED Test
The optical spectrum of visible LEDs used in a wide variety of applications
such as lighting, indication, and measurement can be measured and
analyzed. By supporting the large core fiber input, the AQ6373B can
efficiently acquire the LED light and measure its spectrum. The standard
built-in color analysis function automatically evaluates a dominant
wavelength and XYZ color coordinates.
Higher resolution measurement is possible in 400 to 470 nm range.
Color analysis of white LED
AQ6373B
Optical fiber
Visible LED
FWHM = 0.011nm
Example of 405 nm FP-LD measurement (Resolution setting: 0.01 nm)
52
Optic
al M
easu
ring
Inst
rum
ents
Optical Measuring Instruments
High performance and cost-effective Optical Wavelength Meter
Exceeding the testing needs of optical devices and transmission systems
Model and Suffix Codes
Model Suffix Descriptions
AQ6150 AQ6150 Optical Wavelength Meter
AQ6151 AQ6151 Optical Wavelength Meter
Spec code -10 Base model
Power cord -D UL/CSA standard, and PSE standards
-F VDE standard
-R AS standard
-Q BS standard
-H GB standard
-N NBR standard
Optical connector
(Factory option)
/FC AQ9441(FC) Universal Adapter
/SC AQ9441(SC) Universal Adapter
Optical Wavelength Meter AQ6150 series
Applications
The AQ6150 series optical wavelength meter is an ideal instrument for accurately measuring the optical wavelength of optical devices and systems used in telecommunication applications from 1270 to 1650 nm. By employing a Michelson interferometer and a high speed Fast Fourier Transform (FFT) algorithm, the AQ6150 series can measure not only a single wavelength laser signal but also a multiple wavelength laser signal from a DWDM system and Fabry-Perot laser.
• Wavelength Range: 1270 to 1650 nm
• Wavelength accuracy: ±0.3 pm (AQ6151), ±1 pm (AQ6150)
• Simultaneous measurement of up to 1024 wavelengths
• Cope with modulated light and optical filter measurement
• Increase throughput with high speed measurement
• Reduce the lifetime ownership costs
• logging data function
• Add WDM (OSNR) analysis
• Abundant functions to increase work efficiency
Features
WDM system (Transmitter)
TX
TX
EDFATX
MU
X
TX
TX
λ1
λ2
λ3
λ4
λn
RX
RX
RX
DE
MU
X
RX
RX
λ1
λ2
λ3
λ4
λnλmλm
WDM system (Receiver)
Optical output of WDM system
Optical output of optical devices
(Laser/TOSA/Optical transceiver/
Optical transponder, etc.)
Input signal of
optical receiver
EDFA ROADM EDFA EDFA
Send the command to initiate
Measurement & Analysis Data transfer
SSS dSSSendSend hththe com ddmand to initiate
MMeasurem tent && Analysisy Data transfer 0.3 sec
Multi wavelength view Optical spectrum view
Other modes:Single wavelength view, Delta wavelength view, Grid view, and List view
WDM transmission systems
• Simultaneous measurement of multi channel and narrow spacing WDM system
• Precise adjustment and inspection of laser sources• Measurement of modulated signals
Lasers / optical transceivers
• Precise adjustment and inspection of tunable lasers• Modulated signal measurement of optical transceivers and transponders.• Measurement of all channels of 40 G and 100 G optical transceivers with
WDM technology. Calibration of test systems
• Calibration of optical spectrum analyzers.• Calibration of DFB lasers for optical amplifier test system.• Calibration of tunable lasers for passive component test systems.
Product Lineup
There are two models in the series. The High Accuracy AQ6151 model offers an accuracy of ±0.3 pm to meet the most demanding precision requirements.The Standard Accuracy AQ6150 offers a ± 1 pm accuracy for applications with less demanding requirements at a more affordable price.
Specifications
Increase throughput with high speed measurement
Various view modes
Both models can acquire, analyze and transfer a measurement to a PC within 0.3 seconds. This vastly improves production throughput.
Model Accuracy Key applications
AQ6150 ± 1 pmInspection of DFB-LDs, Tunable lasers, Optical transceivers.
WDM transmission systems
AQ6151 ± 0.3 pmAdjustment, characterization, and inspection of Laser chips,
Tunable lasers, WDM transmission systems, etc.
Model Accuracy Key applications
Applicable optical fiber SM (ITU-T G.652)
Wavelength range 1270 to 1650 nm
Wavelength accuracy AQ6150: ±0.7 ppm (±1 pm at 1550 nm)
AQ6151: ±0.2 ppm (±0.3 pm at 1550 nm)
Min. resolvable separation 5 GHz (40 pm at 1550 nm)
Display resolution (Wavelength) 0.0001 nm
Power accuracy ±0.5 dB (1550 nm, -10 dBm)
Linearity ±0.3 dB (1550 nm, -30 dBm or higher)
Polarization dependency ±0.5 dB (1550 nm)
Display resolution (Power) 0.01 dB
Max. number of wavelengths 1024
Min. input power -40 dBm (1270 to 1600 nm, single line input)
-30 dBm (1600 to 1650 nm, single line input)
Max. input power +10 dBm (total of all lines)
Safe max. input power +18 dBm (total of all lines)
Return loss 35 dB
Measurement time 0.3 s or less (single measurement)
Display 5.7-inch color LCD (640 × 480 dots)
Data storage Internal: 256 MB or more, External: USB
Interfaces GP-IB, ETHERNET, USB, VGA output
Remote control GP-IB, ETHERNET
Optical connector FC/PC or SC/PC (AQ9441 Universal adapter)
Dimensions Approx. 426 (W) × 132 (H) × 450 (D) mm
Mass Approx. 11 kgPlease refer to the product brochure for details.
53
Optic
al M
easu
ring
Inst
rum
ents
Optical Measuring Instruments
Build Your Own Test Configurations in Small Footprint
Applications
• Frame controllers
AQ2211 Frame controller (3 slots for modules)
AQ2212 Frame controller (9 slots for modules)
• Light source modules
AQ2200-131 Grid TLS module (C/L-band, 1 channel)
AQ2200-132 Grid TLS module (C/L-band, 2 channels)
• Sensor modules
AQ2200-215 Sensor module (+30 dBm, 970-1660 nm, 1-slot)
AQ2200-221 Sensor module (Dual sensor, 800-1700 nm, 1-slot)
• Optical attenuator modules
AQ2200-311A ATTN module [w/ Monitor output (optional)] (SMF or
MMF, 1-slot)
AQ2200-331 ATTN module [w/ built-in monitor power meter] (SMF or
MMF, 1-slot)
AQ2200-342 DUAL ATTN module [w/ built-in monitor power meter]
(SMF, 1-slot)
• Optical switch modules
AQ2200-411 OSW module (1 × 4 or 1 × 8, SMF or MMF, 1-slot)
AQ2200-412 OSW module (1 × 16, SMF, 2-slot)
AQ2200-421 OSW module (1 × 2 or 2 × 2, SMF or MMF, 1-slot)
• Modules for Optical Transceiver
AQ2200-642 Transceiver interface module (2-slot)
AQ2200-651 SG module (2-slot)
Frame and Module Lineup
• GE-PON ONU/OLT measurement system
• GE-PON optical three wavelength filter measurement
• Optical amplifier measurement system
• Optical transceiver measurement system
The AQ2200 Multi Application Test System is the ideal system for measuring and evaluating a wide range of optical devices and optical transmitters.
• Flexible and space effective
• Easy-to-View TFT color display
• Remote operation through Ethernet network
• Built-in applications
• Optical power stability measurement
• Short-term optical power fluctuation measurement
• Wide variety of plug-in modules
• Hot-swappable modules
Features
Transceiver Measurement System Optical Fiber Amplifier Measurement System
Multi Application Test System AQ2200
Rx
Transceiver(DUT)
Tx
AQ2200-331ATTN
AQ6370DOptical
Spectrumanalyzer
AQ2212 Frame controller
Tx
10 G BERT
Rx
AQ2200-221OPM
AQ2200-642Transceiver I/F
AQ2200-651SG
AQ2200-411OSW
(1 × 4)
AQ2200-215high-power OPM
AQ6370DOptical
SpectrumAnalyzer
DUT
Opticalfiber
amplifer
AQ2200-421(2/2)OSW
(1 × 2)
AQ2200-421(1/2)OSW
(1 × 2)
AQ2200-311AATTN
AQ2200-132×8
MUX
AQ2212 Frame Controller
Grid TLS
Grid TLS
Grid TLS
Grid TLS
AQ2200-342×8
DUAL ATTN
DUAL ATTN
DUAL ATTN
DUAL ATTN
The 10 Gbit/s optical transceiver modules such as XFP or SFP+ are
frequently used in transmission systems and Ethernet systems.
The measuring system for such modules requires many instruments
including power supplies, multi-meters and the signal generators to control
optical transceiver modules.
The AQ2200 Multi Application Test System allows for building a space
saving test system with a variety of plug-in modules.
An optical fiber amplifier is an
indispensable device for WDM
transmission systems. This
measurement system characterizes
gains and noise figures (NF) of the
fiber amplifier by measuring input
light to an optical fiber amplifier,
which was multiplexed using
multiple light sources, as well as
amplified output light with an optical
spectrum analyzer. A high-power sensor allows for measuring total output
power.
[Measurement items]
• Gain, NF, and total output power
AQ6370D Measurement Screen
54
Optic
al M
easu
ring
Inst
rum
ents
Optical Measuring Instruments
Model and Suffix Code
General Specifications
Display: 8.4-inch color TFT LCD Multi-touch capacitive touchscreen
Power supply: AC adapter voltage 100 to 120 VAC or 200 to 240 VAC (auto
switching) Battery(Li-ion) operation time 15 hours (Telcordia
GR-196-CORE Issue 2). 10 hours (continuous measurement)
Electrical I/F: Unit interface × 1, module interface × 1, USB 2.0 × 3,
Ethernet × 1*1, SD card slot × 1
Dimensions: 287 mm (W) × 210 mm (H) × 80 mm (D)
Weight: Approx. 2.2 kg (OTDR mainframe)*1 option
Features
The AQ7280 succeeds the high-end AQ7275 OTDR, which has been used
for the installation and maintenance of a wide range of network systems,
including core, metro, and access networks.
The AQ7280 has a best-in-class 8.4-inch capacitive touchscreen that supports
the same intuitive multi-touch functionality found in smartphones and other
handheld devices, allowing users to reposition and resize objects on the
screen. The AQ7280 also has the same operation hard keys found on the
preceding model. Users can opt to use either the touchscreen or the hard
keys.
The AQ7280 series offers remarkable flexibility and convenience with
modular measuring units that can be replaced in the field. As new measuring
units are developed to keep up with advances in optical technology, the
AQ7280 can be modified simply by replacing the measuring unit.
Specifications by Model
Optical Time Domain Reflectmeter AQ7280
OTDRunit
Number of
wavelength
Dynamic range (dB) Test application Fiber network
SM1310 (nm)
SM1383(nm)
SM1490 (nm)
SM1550 (nm)
SM1625 (nm)
SM1650 (nm)
MM 850 (nm)
MM 1300 (nm)
InstallationMaintenance
Core Metro Access PONMMfiberDark Live
AQ7282A 2 38 36
AQ7283A 2 42 40
AQ7284A 2 46 45
AQ7285A 2 50 50
AQ7283E 3 42 40 40*1
AQ7283F 3 42 40 40*1
AQ7283H 3 42 40 39 *2
AQ7284H 3 46 45 44 *2
AQ7282G 3 38 36 36
AQ7283K 4 42 38 40 40 *2
AQ7283J 4 42 39 40 40 *2
AQ7282M 2 25 27
*1: Port2, Built-in filter
*2: Using an external filter
OTDR Mainframe
Models Suffix codes Descriptions
AQ7280 AQ7280 OTDR Mainframe
Language -HJ Japanese/English
-HE English (Multi language)
-HM Chinese
-HC Chinese/English
-HK Korean/English
-HR Russian/English
Options /FST Fiber Surface Test function
/MNT Monitoring function
/SMP Smart Mapper function
/LAN Ethernet
/SB Shoulder Belt
Standard accessories; Battery pack, hand belt, user’s manual (CD-ROM), operation guide
AC adapter (Not included in AQ7280. Please order separately.)
Models Suffix codes Descriptions
739871 AC Adapter*1, *3
739872 AC Adapter*2, *3
*1: For outside the US and the countries that require CE marking.
*2: For the US and the countries that require CE marking.
*3: Used with power cord. Refer the bulletin of AQ7280 OTDR for the select.
OTDR units
Models Suffix codes Descriptions
AQ7282A 2WL 1310/1550 nm 38/36 dB
AQ7283A 2WL 1310/1550 nm 42/40 dB
AQ7284A 2WL 1310/1550 nm 46/45 dB
AQ7285A 2WL 1310/1550 nm 50/50 dB
AQ7283E 3WL 1310/1550,1625 nm 42/40, 40 dB*4
AQ7283F3WL 1310/1550,1650 nm 42/40, 40 dB
(1650 nm port is equipped with a built-in filter)
AQ7283H 3WL 1310/1550/1625 nm 42/40/39 dB
AQ7284H 3WL 1310/1550/1625 nm 46/45/44 dB
AQ7282G 3WL 1310/1490/1550 nm 38/36/36 dB
AQ7283K 4WL 1310/1490/1550/1625 nm 42/38/40/40 dB
AQ7283J 4WL 1310/1383/1550/1625 nm 42/39/40/40 dB
AQ7282M 2WL 850/1300 nm (MM) 25/27 dB
Optical
connector-USC Universal Adapter (SC)
-UFC Universal Adapter (FC)
-ULC Universal Adapter (LC)
-ASC Universal Adapter (SC Angled-PC)*1
-NUA No universal adapter
Options /PC Power Checker*1, *2
/SLS Stabilized Light Source*3
*1: Not applicable to AQ7282M
*2: Not applicable to the Port2 of AQ7283E and AQ7283F
*3: Not applicable to the wavelength 1383 nm of AQ7283J.
*4: The port for 1650 nm or 1625 nm is equipped with a built-in filter.
OPM/VLS modules
Models Suffix codes Descriptions
AQ2780 OPM Module
AQ2781 High Power OPM Module
AQ2780V OPM & VLS Module
AQ2781V High Power OPM & VLS Module
Optical
connector-SCC Universal Adapter (SC)
-FCC Universal Adapter (FC)
-LMC Ferrule Adapter (ϕ 1.25)
Models Suffix codes Descriptions
AQ4780 VLS Module
Application Software
Models Suffix codes Descriptions
735070 AQ7932 Emulation Software (Ver. 5.01 or later)
-EN English
-JA Japanese
-CH Chinese
-KO Korean
735071 AQ7940 Optical Fiber Monitoring Software (Ver. 5.01 or later)
-HE English
-HJ Japanese
735050 Additional option license for AQ7280
-FST Fiber Surface Test function
-MNT Monitoring Function
-SMP Smart Mapper Function
55
Optic
al M
easu
ring
Inst
rum
ents
Optical Measuring Instruments
MFT-OTDR AQ1200
Features
Model and suffix code
The AQ1200 is a multifunctional handheld OTDR that combines all the
necessary field test functions in one unit. It offers various functions, including
an OTDR function that features short 80 cm event dead zone, a fault locator
function that is effective in locating a fault, a loss test function (option) that
combines light sources and an optical power meter in one unit, and a visible
light source (option). You can also connect a fiber end-face inspection probe.
The AQ1200 retains the interface of the very popular AQ7252 series. So you
can use the variety of functions and the user-friendly interface.
Light source & Optical power meter option
Option Optical Power Meter (/SPM) Standard (/SLT) High power (/HLT) PON (/PPM) Stabilized Light Source (/SLS)
Optical Power meter
Wavelength setting850/1300/1310/1490/1550/1625/1650 nm, 800 to 1700 nm (1 nm steps),
or CWDM wavelength (1270 to 1610 nm 20 nm steps)1310/1490/1550 nm –
Applicable fiber SM (lTU-T G 652), GI (50/125 μm), GI (62.5/125 μm) SM (lTU-T G 652) –
Power range+10 to -70 dBm (CW)
+7 to -60 dBm (CHOP)+27 to -50 dBm (CW)
+24 to -50 dBm (CHOP)+10 to -70 dBm (CW)+27 to -50 dBm (CW)
–
Noise level 0.5 nW (-63 dBm, 1310 nm) 50 nW (-43 dBm, 1310 nm)0.5 nW (-63 dBrn, 1310nm)50 nW (-43 dBm, 1550nm)
–
Uncertainty under standard conditions
±5 % ±0.5 dB –
Readout resolution 0.01 –
Level unit Absolute: dBm, mW, μW, nW, Relative: dB –
Modulation mode CW, CHOP (270 Hz/1 kHz/2 kHz) –
Average function 1, 10, 50 and 100 times –
Light source
Wavelength (nm) –1310/1550 ±0.25 nm (AQ1200A/E, AQ1205A/E/F), 1625 ±10nm (AO1200B/E),
1625 ±25nm (AO1205E), 1650 ±5 nm, 1650 ±10 nm (AQ1200C, AQ1205F)
Optical output level (dBm)
– -3 ±1
Level stability (dB) –±0.05 (1310/1550 nm, AQ1200A/E, AQ1205A/E/F), ±0.15 (1625/1650 nm, AQ1200B/C/E, AQ1205E/F)
Modulation mode – CW, 270 Hz, 1 kHz, 2 kHz
Applicable fiber – SM (lTU-T G 652)
Memory and logging function ‒ Measurement data storage: 10 to 1000 data, Logging interval: 0.5, 1, 2, 5, or 10 sec
Auto loss test function ‒ Loss measurement with light source and optical power meter interlock
–
Factory Installed Options
Model Suffix codes Description
AQ1200A 1310/1550 nm
AQ1200B 1625 nm
AQ1200C 1650 nm
AQ1200E 1310/1550, 1625 nm
AQ1205A 1310/1550 nm, High Dynamic Range
AQ1205E 1310/1550 nm, 1625 nm High Dynamic Range
AQ1205F 1310/1550 nm High Dynamic Range, 1650 nm
Language
-HE English
-HC Chinese/English
-HK Korean/English
-HR Russian/English
Powercord
-D UL/ CSA standard
-F VDE standard
-R AS standard
-Q BS, Singapore standard
-H GB standard, Complied with CCC
-P EK standard (S. Korea)
-T BSMI standard
-N Brazil standard
Optical connector
-USC SC type
-UFC FC type
-ASC SC/Angled-PC type
light source &optical power meter
/SLT Stabilized light source & Standard optical power meter
/HLT Stabilized light Source & High power optical power meter
/PPM Light source & PON Power meter
/SLS Stabilized light source
/SPM Standard optical power meter
Visible light source /VLS Optical connector: 2.5 ϕ ferrule
PON measurement*1 /PN PON measurement mode
Ethernet /LAN 10BASE T/100BASE TX (PING test, Remote control)
Shoulder belt /SB Shoulder belt
AC adapter /AC1 Attach 739872 AC adapter*2
*1: Only for AQ1200A. AQ1200B/C/E and AQ1205A /E/F come equipped this function.
*2: For the US and the countries that require CE marking.Specifications
Model AQ1200A AQ1200B AQ1200C AQ1200E AQ1205A AQ1205E AQ1205F
Measured wavelength (nm)1310±20(typ)/1550±20(typ)
1625±101650±5, 1650±10
1310±20(typ)/1550±20(typ),
1625±10
1310±20(typ)/1550±20(typ)
1310±20(typ)/1550±20(typ), 1625±20(typ)
1310±20(typ)/1550±20(typ),
1650±5, 1650±10
Optical Port PORT2 PORT2, 3 PORT2 PORT2, 3
Measured fiber SM (ITU-T G.652)
Distance range(km) 0.5, 1, 2, 5, 10, 20, 50, 100, 200, 300, 400, 512 0.5, 1, 2, 5, 10, 20, 50, 100, 200, 300, 400, 512
Pulse width(ns) 3, 10, 20, 50, 100, 200, 500, 1000, 2000, 5000, 10000, 20000 3, 10, 20, 50, 100, 200, 500, 1000, 2000, 5000, 10000, 20000
Event Dead zone (typ.) 0.75 m
Attenuation Dead zone (typ.) 4 m/5 m 7 m 4 m/5 m, 7 m 4 m/5 m 4 m/5 m, 7 m
Dynamic range(dB)(typ.) 34/32 33 34 38/36,36 42/40 42/40,38 42/40,37
Loss measurement accuracy ±0.05 dB or ±0.05 dB/dB
Optical connector Universal Adapter SC, FC
Output power control – Normal/ Low – Normal/ Low
Laser safety standard Class 1M
Ethernet Interface (/LAN) option
Interface 10BASE-T/100BASE-TX
Function Ping test and remote control
Visible Light Source (/VLS) option
Optical connector 2.5 mm type ferrule
Wavelength and optical output level 650 nm± 20 nm, -3 dBm or more (peak)
Modulation mode CHOP approx. 2 Hz
Laser class 3R
56
Optic
al M
easu
ring
Inst
rum
ents
Optical Measuring Instruments
Optical Power Meter
Model AQ2170 AQ2170H AQ2180 AQ2180H
Wavelength Setting 850/1300/1310/1490/1550/1625/1650 nm 1310/1490/1550/1625/1650 nm 850/1300/1310/1490/1550/1625/1650 nm 1310/1490/1550/1625/1650 nm
Photo Detector InGaAs InGaAs
Optical FiberSM (ITU-T G.652), GI (50/125 μm),
GI (62.5/125 μm) In fiberSM (ITU-T G.652) In fiber
SM (ITU-T G.652), GI (50/125 μm),
GI (62.5/125 μm) In fiberSM (ITU-T G.652) In fiber
Optical Connector FC, SC, LC, ferrule2.5, ferrule1.25 (Standard) FC, FC, SC, LC, ferrule2.5, ferrule1.25 (Standard)
Power Range -70 to +10 dBm -50 to +26 dBm -70 to +10 dBm -50 to +26 dBm
Noise Level -60 dBm -40 dBm -60 dBm -40 dBm
Uncertainty ±5% ±5% ±5% ±5%
Display Resolution 0.01 dB (> -60 dBm), 0.1 dB (-60 dBm) 0.01 dB (> -40 dBm), 0.1 dB (-40 dBm) 0.01 dB, 0.01 dBm, 0.0001 μW
Unit ABS value: dBm, mW, μW / Relative value: dB ABS value: dBm, mW, μW / Relative value: dB
Modulation CW, CHOP (270 Hz, 1 kHz, 2 kHz) CW, CHOP (270 Hz, 1 kHz, 2 kHz)
Memory function — 999 records
I/O — USB-B (mini)
Power Source Four AAA Cell batteries Two AA Cell batteries
Battery life time 40 hours 40 hours
Dimensions (mm) Weight 63 (W) × 116 (H) × 35 (D) approx.160 g 76 (W) × 153 (H) × 43 (D) approx.280 g
Optical Light Source
Model AQ4280A AQ4280B AQ4280C
Element LD
Fiber SM (ITU-T G.652)
Wavelength 1310/1550 ± 20 nm 1310/1550±20 nm, 1490±10 nm 1310/1550±20 nm, 1490/1625±10 nm
Spectral width < 5 nm (1310 nm), < 10 nm (1550 nm) < 5nm (1310 nm, 1490 nm), < 10nm (1550 nm) < 5nm (1310 nm, 1490 nm, 1625 nm) < 10nm (1550 nm)
Output power level -5 dBm ± 1 dB -5 dBm ± 1 dB -5 dBm ± 1dB
Power stability (15 min) < ± 0.05 dB < ± 0.05 dB (1310/1550 nm)< ± 0.1 dB (1490 nm) < ± 0.05 dB (1310/1550 nm)< ± 0.1 dB (1490/1625 nm)
Modulation CW, CHOP (270 Hz, 1 kHz, 2 kHz)
Power Source Three AA Cell batteries
Battery life time 25 hours
Laser Class CLASS1 (IEC 60825-1)
Dimensions (mm) Weight 76 (W) × 153 (H) × 43 (D) approx.300 g
AQ2170 Optical Power Meter AQ2180 Optical Power Meter AQ4280 Optical Light Source
AQ2170
AQ2170H
AQ2180
AQ2180H
AQ4280A
AQ4280B
AQ4280C
Features
Specifications by model
Standard Accessory
Due to the increase in broadband services such as FTTH (Fiber To The Home), the communication carriers are
reinforcing the infrastructure of optical fiber networks. In the introductory period of such networks, there is a strong
need for handy OPM/LS for installation and maintenance together with OTDRs. the AQ2170, AQ2170H, AQ2180
and AQ2180H Optical Power Meters, and the AQ4280A, AQ4280B and AQ4280C Optical Light Sources to address
installation and maintenance needs.
Connector adapter (FC, SC, LC, ferrule2.5, ferrule 1.25), Four AAA Cell batteries, Carrying pouch, Protector, Operation Guide, User's Manual (CD)
Connector adapter (FC, SC, LC, ferrule2.5, ferrule 1.25), Two AA Cell batteries, Carrying pouch, Protector, Operation Guide, User's Manual (CD)
Universal adapter (FC/PC, SC/PC, ST/PC Standard), Two AA Cell batteries, Carrying pouch, Protector, Operation Guide, User's Manual (CD)
AQ2170 Optical Power Meter AQ2180 Optical Power Meter AQ4280 Optical Light Source
57
Optic
al M
easu
ring
Inst
rum
ents
Optical Measuring Instruments
MFT-OLTS AQ1100
Model and Suffix Codes
General Specifications
The AQ1100 is an optical loss test set combining an optical power meter and
light sources in one unit. An optical power meter is a measuring instrument
usually used for optical loss tests. The AQ1100 supports up to MM850/1300
nm and SM1310/1550/1625 nm. Also, you can select a +27 dBm high power
optical meter. For the light source, three models are available depending on the
wavelength and fiber type used. For the optical power meter, you can select
from three models depending on the measurement power and the purpose of the
optical power meter.
Features
Display: 5.7-inch color LCD (640 × 480)
Loss test mode (only with /SPM or /HPM): Auto loss test, Loopback
test, Multi-core loss test
External interface: USB1.1 Type A and Type B (mini) × 1
Power supply: AC adapter voltage 100 to 120 VAC or 200 to 240 VAC (auto-
switching)
Battery (Li-ion) operation time 6 hours and charging time 5 hours
External dimensions: Approx. 217.5 mm (W) × 157 mm (H) × 74 mm (D)
Weight: Approx. 1 kg or less (including internal battery)
Model Suffix codes Description
AQ1100A LS: 1310/1550 nm
AQ1100B LS: 1310/1550/1625 nm
AQ1100D LS: MM850/1300, SM1310/1550 nm
Language
-HJ Japanese/English
-HE English
-HC Chinese/English
-HK Korean/English
-HR Russian/English
Power cord
-D UL/ CSA standard
-F VDE standard
-R AS standard
-Q BS, Singapore standard
-H GB standard, Complied with CCC
-P KC standard (S. Korea)
Optical power meter
-SPM Optical power meter
-HPM High power optical power meter
-PPM (AQ1100A only) PON Optical power meter
Optical connector
-USC SC type (LS port, and OPM port)
-UFC FC type (LS port, and OPM port)
-ULCLC type (LS port, and OPM port for -PPM),
ϕ 1.25 adapter(OPM port for -SPM and -HPM)
-ASC
(except AQ1100D)
SC/Angled-PC type (LS port, and OPM port for -PPM),
SC type (OPM port for -SPM and -HPM)
Factory installed options
/VLS Visible light source, optical connector: 2.5ϕ ferrule
/LAN Ethernet (10/100BASE-TX)
/SB Shoulder belt
AC adapter /AC1 Attach 739872 AC adapter*
* For the US and the countries that require CE marking. Standard Accessories
Power cord, AC adapter, battery pack, hand belt, user's manual (CD-ROM), operation guide
Optional Accessories
Models AQ1100A AQ1100B AQ1100D
Light source
performance
Wavelength (nm) *1 1310/1550 ± 25 1310/1550/1625 ± 251310/1550 ± 25 (SM) 850/1300 ±
30 (GI)
Light emitting device LD LD LD(SM), LED(GI)
SM (LD) spectral width (nm) *1 *2 <5 / <10 <5 / <10 / <10 <5 / <10
GI (LED) spectral width (nm) *1 *3 (FWHM) − − 40(typ)/140(typ)
Optical output level (dBm) -3 ± 1 -3 ± 1SM: -3 ± 1
GI: -20 ± 1
Level stability (dB) *4 ±0.05 ±0.05SM: ±0.05
GI: ±0.1
Modulation mode CW, CHOP(270 Hz, 1 kHz, 2 kHz) *5
Applicable fiber SM (ITU-T G.652) SM (ITU-T G.652)GI (50/125 μm)
Optical connector SC, FC, 1.25 mm ferrule, SC/Angled-PC SC, FC, 1.25 mm ferrule
Laser class 1
Specifications by Model
Model Suffix codes Description
SU2006A Soft carrying case
735480
(For opticalpower meters)
-SCC Connector adapter (SC)
-FCC Connector adapter (FC)
735481 -LMC Ferrule adapter (ϕ 1.25)
SU2005A
(For LS and PON optical power meter)
-SCC Universal adapter (SC)
-FCC Universal adapter (FC)
-LCC Universal adapter (LC)
739871 (AC adpter) -D UL/ CSA standard
-F VDE standard
-R AS standard
-Q BS, Singapore standard
-H GB standard, Complied with CCC
-P KC standard (S. Korea)
739872* (AC adpter) -D UL/CSA standard
-F VDE standard
-Q BS, Singapore standard
739882 Battery pack (Spare)
B8070CY Shoulder belt
* For the US and the countries that require CE marking
Optical Power Meter Performance and Functions
Standard (/SPM) High power (/HMP) PON (/PPM)
Wavelength setting
Simple mode: 850/1300/1310/1490/1550/1625/1650 nm
Detail mode setting range: 850 nm to 1650 nm, 1 nm step
CWDM mode setting range: 1270 nm to 1610 nm 20 nm step
1310/1490/1550 nm
(1490 nm and 1550 nm can be
measured separately)
Applicable fiber SM (ITU-G.652) GI (50/125 μm) SM (ITU-G.652)
Power range (dBm)-70 to +10 (CW)
-70 to +7 (CHOP)
-50 to +27 (CW)
-50 to +24 (CHOP) *6
-70 to +10: 1310/1490 nm
-50 to +27: 1550 nm
Noise level0.5 nW
(-63 dBm, 1310 nm)
50 nW
(-43 dBm, 1310 nm)
0.5 nW(-63 dBm, 1310 nm)
50 nW(-43 dBm, 1550 nm)
Uncertainty under standard
conditions *7±5% ±5% ±0.5 dB (10%)
Readout resolution 0.01
Level unit Absolute: dBm, mW, μW, nW, Relative: dB
Modulation modeCW
CHOP(270/1 k/2 kHz)
CW
CHOP(270/1 k/2 kHz)CW
Average function 1, 10, 50 and 100 times
Logging function Measurement intervals: 500 ms, 1 s, 2 s, 5 s, 10 s, Measurement count: 10 to 1000
Factory Installed Options
Visible light
source (/VLS)
Optical
connector2.5 mm ferrule type
Wavelength and
optical output
level
650 nm ±20 nm, peak
value -3 dBm or more
Modulation
frequencyApprox. 2 Hz
Laser class 3R
LAN interface (/
LAN)
10BASE-
T/100BASE-TX
RJ-45 connector
Ping test, PC remote
control
The specifications are at 23°C ±2°C unless otherwise noted.
*1: 23°C ±2°C, CW
*2: RMS (2 , -20 dB)
*3: Envelope (-3 dB)
*4: for 15 minutes at a constant temperature within 23°C ±2°C
*5: CW and 270 Hz only at 850 nm and 1300 nm
*6: Except for 850 nm and 1650 nm.
*7: 23°C ±2°C , standard conditions (CW, 1310 nm, 100 μW, SMF), at 1550
nm for /PPM.
*8: LD ON. (in screen save mode)
58
Optic
al M
easu
ring
Inst
rum
ents
Optical Measuring Instruments
MFT-1/10GbE AQ1300 Series
General Specifications
Display: 5.7-inch color LCD (640 × 480)
External interface: USB1.1 Type A and Type B (mini), LAN (RJ-45) × 1
Power supply: AC adapter 100 to 240 V, 50 to 60 Hz
Battery (Li-ion) operation time 1 hour
External dimensions: 217.5 (W) × 157 (H) × 74 (D) mm
Weight: Approx. 1.3 kg (including internal battery)
Model and Suffix Codes
Item Specifications
Interface
RJ-45 10BASE-T, 100BASE-TX, 1000BASE-T
SFP 1000BASE-SX, 1000BASE-LX
XFP*7 10GBASE-SR, 10GBASE-LR, 10GBASE-ER
Measurement function
Measurement menu Auto, Auto (Remote), Manual, OPM (Optical power meter)*8
Measurement mode TRAFFIC, QoS, PING, Loop Back, BERT
RFC2544 Throughput, Latency, Frame loss rate, Back-to-Back, Packet Jitter
Transmission functionFrame length 48 to 9999 bytes
QoS transmission Up to 8 channels (up to 4 ch in Auto and Auto (remote) mode)
Receive function
Receivable frame length 48 to 9999 bytes (Minimum IFG: 5 bytes)
Latency time measurement resolution
100 ns
Loop back function Field swap DA/SA of MAC address, DA/SA of IP address, Dst/Src port of TCP/UDP
Remote control function In-band remoteRemote test synchronization, Remote test start synchronization, Opposite tester automatic search(*), Opposite tester automatic addressing (*) ( *: Applicable only within a segment)
Layer-1 measurement functionReceiving clock measurement Measurement range: -100 to +100 ppm Measurement resolution: 0.1 ppm
LFS generation*9 Manual: Continuous transmission (Start/Stop), Auto: When a link down or LF is received, RF is transmitted automatically.
*7: Only available for the AQ1300 *8: Only available for the AQ1300 (option) *9: When the interface is XFP (10 G)
Specifications
Optional Accessories
Model Suffix codes Description
735454 Optical transceiver module
-SR*4 10GBASE-SR XFP module
-LR*4 10GBASE-LR XFP module
-ER*4 10GBASE-ER XFP module
-SX 1000BASE-SX SFP module
-LX 1000BASE-LX SFP module
739882 Battery pack (reserve)
SU2006A Soft carrying case
739871 AC Adapter*5
Power cord -D UL/CSA standard
-F VDE standard
-R AS standard
-Q BS standard
-H GB standard
-P KC standard
-T BSMI standard
739872 AC Adapter*6
-D UL/CSA standard
-F VDE standard
-Q BS, Singapore standard
B8070CY Shoulder belt
735480*4 -SCC SC connector adapter for optical power meters
-FCC FC connector adapter for optical power meters
735481 -LMC ϕ 1.25 connector adapter for optical power meters
-SFC ϕ 2.5 connector adapter for optical power meters
*4: Cannot be used with the AQ1301.
*5: For outside the US and the countries that require CE making.
*6: For the US and the countries that require CE making.
Model Suffix Code Description
AQ1301 AQ1301 MFT-1GbE
AQ1300 AQ1300 MFT-10GbE
Language -HE English
Power Coad -D UL/CSA standard
-F VDE standard
-R AS standard
-Q BS, Singapore Standard
-H GB standard, CCC correspondence
-P KC standard (South Korea)
-T BSMI, Taiwan Standard
Optical power meter*1 /SPML Standard Optical power meter
XFP module*1, *2 /SR 10GBASE-SR XFP module
/LR 10GBASE-LR XFP module
/ER 10GBASE-ER XFP module
SFP module*2 /SX 1000BASE-SX SFP module
/LX 1000BASE-LX SFP module
RFC2544*3 /BM RFC2544 Function
Shoulder belt /SB Shoulder belt
*1: Cannot be specified for the AQ1301
*2: For the SFP and XFP modules, be sure to use the modules listed above.
If you use other than an SFP or XFP module from Yokogawa, the functionality and performance of this product are
not guaranteed. Furthermore, the warranty will be void.
*3: Cannot be specified for the AQ1301 (this option is available for the AQ1301 as standard)
Features
The AQ1300 series is a compact and lightweight Ethernet tester that is
designed to improve both work efficiency and quality at the same time, with
function optimized for the network path testing and maintenance of Ethernet
networks up to 1G or 10G depending on model chosen.
Easy operation prevents operational errors and stabilizes work quality for
routine tasks such as network path testing.
Powerful analysis functions help isolate failures during maintenance work.
The AQ1300 series has two models, AQ1300 and AQ1301 to choose from
depending on the measurement interface and bit rate. You can choose the
model suitable for your test needs.
59
Optic
al M
easu
ring
Inst
rum
ents
Optical Measuring Instruments
High-performance OTDR Module
for Remote Fiber Test Systems
Model and Suffix Code
The AQ7277 is an OTDR module for RFTS (Remote Fiber Test System), which uses the advanced technology transferred from the AQ7275 high performance OTDR.
• Measurement at 1650 nm (Maintenance wavelength)
• Built-in 1310/1550 nm cut filter for live-fiber monitoring
• Allow to test PON system through high-port-count splitter
• Ethernet interface for fast data transfer
Features
External View
Remote OTDR AQ7277
Specifications
Model and suffix code: AQ7277-B01 OTDR optical connector (SC)
DC input +12 V(round jack)
USB connector(Type B)
DC input +12 V(square 4-pin connectorwith lock mechanism)
LED I/F connector(LED drive, PS-20PE)
LAN connector(RJ45)
Note: Dimensions exclude protrusions
Wavelength 1650 ±5 nm
Distance range (km) 0.5, 1, 2, 5, 10, 20, 50, 100, 200, 300, 400
Pulse width (ns) 3, 10, 20, 50, 100, 200, 500, 1,000, 2,000, 5,000, 10,000, 20,000
Sampling resolution 5 cm, 10 cm, 20 cm, 50 cm, 1 m, 2 m, 4 m, 8 m, 16 m, 32 m
Dynamic range 37 dB (typ.)
Event dead zone 0.8 m (typ.)
Attenuation dead zone 12 m (typ.)
Distance measurement accuracy ±1 m ±measurement distance x 2 x 10-5 ±1 sampling resolution
Number of sampling data Max.100,000 points
Control interface LAN (10BASE-T, 100BASE-TX), USB1.1 (Type B)
Alarm output LED drive signal
Environmental conditions Operating temperature 0 to +50°C
Storage temperature -20 to +60°C
Humidity 20 to 85% (no condensation)
DC power supply 12 V DC to 19.5 V DC 1.5 A or less (at 12 V DC), 1 A or less (at 19.5 V DC)
Dimensions and weight 277 mm (W) × 190 mm (D) × 73 mm (H) (excluding protrusions), approx. 2 kg
Laser safety standards Class 1M
60
Cal
ibra
tor
Calibrator
CA700 Pressure Calibrator
Hand Pump Series
High Accurate and High Functional Pressure Calibrator Specially Designed for the Calibration of
Differential Pressure and Pressure Transmitters.
Three High-Performance Hand Pump Models Available
• Smooth pressurization with less internal leaking• Strainer preventing debris from entering the pump included• Low Pressure Hand Pump Pressure generation range: -83 to 700 kPa Ultra-compact hand pump• Pneumatic Hand Pump Pressure generation range: -83 to 4,000 kPa High-performance small hand pump with a wide range of pressure generation•Hydraulic Hand Pump Pressure generation range: 0 to 70 MPa High-performance hand pump capable of generating a pressure of up to 70
MPa
Pressure MeasurementModel CA700-E-01 CA700-E-02 CA700-E-03
Pressure type Gauge
Measurement
range
Positive pressure 0 to 200 kPa
Negative pressure -80 to 0 kPa
Positive pressure 0 to 1,000 kPa
Negative pressure -80 to 0 kPa
Positive pressure 0 to 3,500 kPa
Negative pressure -80 to 0 kPa
Measurement
display rangeUp to 240.000 kPa Up to 1,200.00 kPa Up to 4,200.00 kPa
Measurement
accuracy
(6 months after
calibration)
(Tested after
zero calibration)
Positive pressure
20 to 200 kPa:
±(0.01% of reading + 0.003 kPa)
0 to 20 kPa: ±0.005 kPa
Positive pressure
±(0.01% of reading + 0.04 kPa)
Positive pressure
±(0.01% of reading + 0.15 kPa)
Negative pressure
±(0.2% of reading + 0.090 kPa)
Negative pressure
±(0.2% of reading + 0.08 kPa)
Negative pressure
±(0.2% of reading + 0.08 kPa)
Measurement
fluidGas and liquid (non-corrosive, non-flammable, non-explosive, and non-toxic fluids)
Pressure
display units
kPa and other units
(Pa, hPa, MPa, mbar, bar, atm, mmHg, inHg, gf/cm2, kgf/cm2, mmH2O@4˚C, mmH2O@20˚C,
ftH2O@4˚C, ftH2O@20˚C, inH2O@4˚C, inH2O@20˚C, Torr, psi)
Input port Rc 1/4 or 1/4 NPT female thread (selectable)
Current and Voltage Measurement (common to all models)
DC current0 to ±20.000 mA ±(0.015% of reading + 3 μA)
0 to ±100.00 mA ±(0.015% of reading + 30 μA)
DC voltage0 to ±5.0000 V ±(0.015% of reading + 0.5 mV)
0 to ±50.000 V ±(0.015% of reading + 5 mV)
24 V Loop power supply
Supply
voltage
24 V ± 1 V Load current 24 mA when communication resistance OFF
24 V ± 6 V Load current 20 mA when communication resistance ON
Current and voltage source (common to all models)DC current* 0 to 20.000 mA ±(0.015% of setting + 3 μA)
DC voltage 0 to 5.0000 V ±(0.015% of setting + 0.5 mV)
* External power supply for 20 mA SIMULATE: 5 to 28 V
Main Specifications
Example of field calibration of differential pressureand pressure transmitter
Calibration of pressure transmitters is required to accurately measure the
input and output values and to calculate the error rate.
The CA700 ensures reliable calibration with its function to accurately
measure the input and output values of pressure and current. Additionally
its embedded calibration procedures enable users to perform certain
calibration following the prescribed procedure.
Hand pump Differential pressure and pressure transmitter
Product name Model Description of kit (individual models)
Hand Pump Kit (Low pressure) 91050 Hand Pump (91051), Connector Set (91052), Case (93052)
Hand Pump Kit (Pneumatic) 91055 Hand Pump (91056), Connector Set (91057), Case (93053)
Hand Pump Kit (Hydraulic) 91060 Hand Pump (91061), Connector Set (91062), Case (93053)
CA700
Detailed catalog: Bulletin CA700-EN
Model 91050 Model 91055 Model 91060
Detailed catalog: Bulletin CA700-EN
Features
Features
• Basic accuracy: Pressure (measurement) 0.01% rdg Current (source/measurement) 0.015% rdg Voltage (source/measurement) 0.015% rdg• Widest range and highest resolution in class achieved 200 kPa gauge pressure model (resolution 0.001 kPa) 1000 kPa gauge pressure model (resolution 0.01 kPa) 3500 kPa gauge model (resolution 0.01 kPa)• DC mA signals can be measured by supplying power to the transmitter from
a 24V DC power supply.• Calibration procedures of pressure transmitters and pressure switches are
embedded. “As Found”, “ As Left” data and error rate (%) can be recorded.• IP54 dustproof and waterproof robust case enables use in harsh environments.• Hart and Brain communication resistance is embedded.• Dimensions: Approx. 264 (W) × 188 (H) × 96 (D) mm Weight: Approx. 2 kg (including 6 AA size batteries)
61
Cal
ibra
tor
Calibrator
Features
• Highly accurate within 0.02% of the DC voltage range for source and measure• Source and measurement can be performed simultaneously• Vertical body with large-screen display• Loop power supply function (24 V DC at a load of max 22 mA) It is possible to measure current in the mA range while supplying power• Sink function• Sweep functions that allow 3 types of continuous outputs: Step sweep function Linear sweep function Program sweep function
Optional Accessories (sold separately)
High accuracy and compact design
CA150Handy Calibrator
Specifications
General Specifications
Common source specifications• Power supply: 6 AA size alkaline batteries AC adapter (sold separately) or dedicated NiMH battery (sold separately)• Battery life Conditions: Simultaneous Source/measurement When 6 batteries are used: Approx. 8 hours When NiMH battery is used: Approx. 10 hours• Auto power-off: Approx. 10 minutes• Insulation resistance: Between input terminal and output terminal: 500 V DC, 50 MΩ or more• Withstand voltage: Between measurement terminal and generation terminal: 350 V AC, 1 minute• Operating temperature/humidity range: 0 to 40°C, 20 to 80%RH (no condensation)• Storage temperature range: -20 to 60°C 90%RH or less (no condensation)• External dimensions: Approx. 251 × 124 × 70 mm• Weight: Approx. 1000 g (with Batteries)• Conforming Standards: Safety EN61010-1, UL61010-1, CAN/ CSA C22.2 No. 61010-1 EMC EN 61326 Class B; EN 55011 Class B Group1 EN 61000-3-2; EN 61000-3-3
Product name
94010
AC adapter
B9108WA
For reference junction compensation
RJ sensor
B9108XA
Lead cables, RJ sensor, etc. can be stored.
Accessory storage case
94015
NiMH battery Dedicated
NiMH battery
93027
With strap and accessory storage case
Main body case
98064
Alligator clip, CAT I, for controlsignal only (under 70 V)
One set of 1 red and 1 black cablesLength: Approx. 1.7 m
Lead cable for measurement
Model name
Remark
-D-F-H-N-P-R-S
For UL/CSA StandardFor VDE StandardFor GB StandardFor NBR StandardFor KC StandardFor AS StandardFor BS Standard
Range Resolution Source range Accuracy
100 mV 1 μV 0 to ±110.000 mV ±(0.02% + 10 μV)
1 V 10 μV 0 to ±1.10000 V ±(0.02% + 0.05 mV)
10 V 0.1 mV 0 to ±11.0000 V ±(0.02% + 0.5 mV)
30 V 10 mV 0 to ±30.00 V ±(0.02% + 10 mV)
DC current 20 mA 1 μA 0 to +22.000 mA ±(0.025% + 3 μA)
mA SINK 20 mA SINK 1 μA 0 to -22.000 mA ±(0.025% + 6 μA)
500 Ω 0.01 Ω 0 to 550.00 Ω ±(0.02% + 0.1 Ω)
5 kΩ 0.1 Ω 0 to 5.5000 kΩ ±(0.05% + 1.5 Ω)
50 kΩ 1 Ω 0 to 55.000 kΩ ±(0.1% + 50 Ω)
PT100 -200.0 to 850.0°C ±(0.025% + 0.3°C)
JPT100 -200.0 to 500.0°C
K -200.0 to -100.0°C ±(0.02% + 0.8°C)
-100.0 to 1372.0°C ±(0.02% + 0.5°C)
E -200.0 to -100.0°C ±(0.02% + 0.6°C)
-100.0 to 1000.0°C ±(0.02% + 0.4°C)
J -200.0 to -100.0°C ±(0.02% + 0.7°C)
-100.0 to 1200.0°C ±(0.02% + 0.4°C)
T -200.0 to -100.0°C ±(0.02% + 0.8°C)
-100.0 to 400.0°C ±(0.02% + 0.5°C)
N -200.0 to 0°C ±(0.02% + 1.0°C)
0.0 to 1300.0°C ±(0.02% + 0.5°C)
L -200.0 to 900.0°C ±(0.02% + 0.5°C)
U -200.0 to 0°C ±(0.02% + 0.7°C)
0 to 400.0°C ±(0.02% + 0.5°C)
R 0 to 100°C ±(0.02% + 2°C)
100 to 1768°C ±(0.02% + 1.2°C)
S 0 to 100°C ±(0.02% + 2°C)
100 to 1768°C ±(0.02% + 1.2°C)
B 600 to 1000°C ±(0.02% + 1.5°C)
1000 to 1820°C ±(0.02% + 1°C)
100 Hz 0.01 Hz 1.00 to 110.00 Hz ±0.05 Hz
1000 Hz 0.1 Hz 90.0 to 1100.0 Hz ±0.5 Hz
10 kHz 0.1 kHz 0.9 kHz to 11.0 kHz ±0.1 kHz
50 kHz 1 kHz 9 kHz to 50 kHz ±1 kHz
CPM 0.1 CPM 1.0 to 1100.0 CPM ±0.5 CPM
Range Resolution Measurement range Accuracy
500 mV 10 μV 0 to ±500.00 mV ±(0.02% + 50 μV)
5 V 0.1 mV 0 to ±5.0000 V ±(0.02% + 0.5 mV)
35 V 1 mV 0 to ±35.000 V ±(0.025% + 5 mV)
20 mA 1 μA 0 to ±20.000 mA ±(0.025% + 4 μA)
100 mA 10 μA 0 to ±100.00 mA ±(0.04% + 30 μA)
500 Ω 0.01 Ω 0 to 500.00 Ω ±(0.055% + 0.075 Ω)
5 kΩ 0.1 Ω 0 to 5.0000 kΩ ±(0.055% + 0.75 Ω)
50 kΩ 1 Ω 0 to 50.000 kΩ ±(0.055% + 10 Ω)
PT100 -200.0 to 850.0°C
JPT100 -200.0 to 500.0°C
K -200.0 to 1372.0°C
E -200.0 to 1000.0°C
J -200.0 to 1200.0°C
T -200.0 to 400.0°C
N -200.0 to 1300.0°C
L -200.0 to 900.0°C
U -200.0 to 400.0°C
R 0 to 1768°C
S 0 to 1768°C
B 600 to 1800°C
100 Hz 0.01 Hz 1.00 to 110.00 Hz
1000 Hz 0.1 Hz 1.0 to 1100.0 Hz ±2 dgt
10 kHz 0.001 kHz 0.001 to 11.000 kHz
CPM 1 CPM 0 to 100000 CPM ----
CPH 1 CPH 0 to 100000 CPH ----
Loop power supply 24 V LOOP 24 V±2 V
Source Unit
Measurement Unit
DC voltage
Resistance
RTD
Thermocouple
DC voltage
DC current
Resistance
Thermocouple
RTD *5
Pulse
Frequency/pulse
0.1°C
0.1°C
0.1°C
±(0.05% + 1.5°C)/-100°Cor more±(0.05% + 2°C)/-100°Cor less
±(0.05% + 0.6°C)
±(0.05% + 2°C)/100°Cor more±(0.05% + 3°C)/100°Cor less
1°C
0.1°C
1°C
Temperature coefficient: Accuracy above x (1/10)/°CThe temperature coefficient is added in the ranges from 0 to 18°C and from 28 to 40°C
Temperature coefficient: Accuracy above x (1/10)/°CThe temperature coefficient is added in the ranges from 0 to 18°C and from 28 to 40°C
Accuracy=±(% of setting + μV, mV, μA, Ω and °C) at 23°C±5°C
Accuracy=±(% of reading + μV, mV, μA, Ω or dgt(digit)) at 23°C±5°C
62
Cal
ibra
tor
Calibrator
Features
• Source and measure operations can be performed at the same time. (Select from the following source signal and measurement signal options:
voltage, current, resistance, thermocouple (TC), resistance temperature detector (RTD), frequency, pulse).
• AC voltages, including supply voltage, can be measured. • Easy operation.• Compact size and Lightweight• Includes a wide array of additional functions. • Source Values set in steps of 4-20 mA 24V DC Power Supply to Transmitter • Divided output (n/m) function Output settings are divided, eliminating the need for bothersome
calculations for percentage output. • Autostep function Changes the output value in step form based on the setting from the
divided output (n/m) function. Changes can be sourced automatically every 10% or 25%.
• Online communication (CA71 only) RS-232C-compliant optically isolated interface • Sweep function Linearly increases or decrease the output. The increasing/decreasing time
can be set to either 16 or 32 seconds. • Memory function Source values and measurements forming individual value sets can be
saved to or read from the Handy Calibrator's internal memory (maximum 50 value sets).
• Temperature monitor function
Simultaneous Signal Source and Measurement Capability
Specifications
General Specifications
CA51/CA71Handy Calibrators
Parameter
Power supply
Battery life
Auto-power-off function
Applicable standards
Operating temperature
and humidity ranges
External dimensions
(WHD)
Weight
Specifications
Four AA alkaline batteries, or special AC adapter (sold separately)
Measurement off, output 5 V DC/10 kΩ or greater: Approximately
40 hours
Simultaneous signal generation/measurement, output 5 V DC/10
kΩ or greater: Approximately 20 hours
Simultaneous signal generation/measurement, output 20 mA/5 V:
Approximately 12 hours
(using alkaline batteries, with backlight off)
Approximately 10 minutes (auto-power-off can be disabled through
a DIP switch setting)
IEC61010-1, IEC61010-2-31
EN61326-1
EN55011, Class B, Group 1
0–50°C, 20–80% RH (no condensation)
Approximately 190 × 120 × 55 mm
Approximately 730 g (including batteries)
Parameter
DC voltage
DC current
mA SINK
Resistance
RTD
TC
Frequency,
pulse
Reference
100 mV
1 V
10 V
30 V
20 mA
4–20 mA
20 mA
400 Ω
Pt100
JPt100
K
E
J
T
N
L
U
R
S
B
500 Hz
1000 Hz
10 kHz
Pulse cycle
Range
-10.00–110.00 mV
0–1.1000 V
0–11.000 V
0–30.00 V
0–24.000 mA
4/8/12/16/20 mA
0.1–24.000 mA
0–400.00 Ω
-200.0–850.0°C
-200.0–500.0°C
-200.0–1372.0°C
-200.0–1000.0°C
-200.0–1200.0°C
-200.0–400.0°C
-200.0–1300.0°C
-200.0–900.0°C
-200.0–400.0°C
0–1768°C
600–1800°C
1.0–500.0 Hz
90–1100 Hz
0.9 kHz–11.0 kHz
1–99,999 cycles
Resolution
10 μV
0.1 mV
1 mV
10 mV
1 μA
4 mA
1 μA
0.01 Ω
0.1°C
0.1°C
1°C
0.1 Hz
1 Hz
0.1 kHz
1 cycle
Accuracy (23±5°C per year)
±(0.02% + 15 μV)
±(0.02% + 0.1 mV)
±(0.02% + 1 mV)
±(0.02% + 10 mV)
±(0.025% + 3 μA)
±(0.05% + 3 μA)
±(0.025% + 0.1 Ω)
±(0.025% + 0.3°C)
±(0.02% + 0.5°C)
(-100°C or greater)
±(0.02% + 1°C)
(-100°C or less)
±(0.02% + 0.5°C)
(0°C or greater)
±(0.02% + 1°C)
(0°C or less)
±(0.02% + 2.5°C)
(100°C or less)
±(0.02% + 1.5°C)
(100°C or greater)
±(0.02% + 2°C)
(1000°C or less)
±(0.02% + 1.5°C)
(1000°C or greater)
±0.2 Hz
±1 Hz
±0.1 kHz
–
Source Unit
Measurement Unit
Parameter
DC voltage
DC current
Resistance
AC voltage
Frequency, pulse
Reference
100 mV
1 V
10 V
100 V
20 mA
100 mA
400 Ω
1 V
10 V
100 V
300 V
100 Hz
1000 Hz
10 kHz
CPM
CPH
Accuracy (23±5°C per year)
±(0.025% + 20 μV)
±(0.025% + 0.2 mV)
±(0.025% + 2 mV)
±(0.05% + 20 mV)
±(0.025% + 4 μA)
±(0.04% + 30 μA)
±(0.05% + 0.1 Ω)
±(0.5% + 5 dgt)
±(0.5% + 2 dgt)
±2 dgt
Resolution
10 μV
0.1 mV
1 mV
0.01 V
1 μA
10 μA
0.01 Ω
1 mV
0.01 V
0.1 V
1 V
0.01 Hz
0.1 Hz
0.001 kHz
1 CPM
1 CPH
• Both CA51 and CA71
Parameter
TC
RTD
Reference
K
E
J
T
N
L
U
R
S
B
Pt100
JPt100
Resolution
0.1°C
1°C
0.1°C
Accuracy (23±5°C per year)
±(0.05% + 1.5°C)(-100°C or greater)
±(0.05% + 2°C)(-100°C or less)
±(0.05% + 2°C)(100°C or greater)
±(0.05% + 3°C)(100°C or less)
±(0.05% + 0.6°C)
• CA71 only
63
Cal
ibra
tor
Calibrator
Process Calibrator CA310, CA320, CA330
High-performance Model Specialized for Loop InspectionCA310Volt mA calibrator
• Basic accuracy: 0.015% (source and measurement accuracy of voltage mA)
• 20 mA SIMULATE (SINK) function• Simultaneously measures 24-V loop power and output signals
with high accuracy• Built-in HART/BRAIN communication resistance (250 Ω)• Sub-display indicates span% of the source value.• Handles various source patterns
(Step sweep/linear sweep/manual step/span check)
Specifications
Source V DC : 500 mV/5 V/30 V mA DC : 20 mA/20 mA SIMULATEMeasurement V DC : 500 mV/5 V/30 V/50 V mA DC : 20 mA/50 mA 24-V loop power source:
24 V±1 V (communication resistance: off) 24 V±6 V (communication resistance: on)
General specifications • Dimensions : 90 (W) × 192 (H) × 42 (D) mm • Weight : Approx. 440 g • Power source : AA battery (LR6) × 4 or dedicated AC/DC
adaptor (option) • Sweep function : Step (25%)/linear • Sweep time : 15 sec/30 sec/45 sec/60 sec
Bulletin: CA300-EN
High-performance Model Specialized for Simulating ThermocouplesCA320TC calibrator
• Basic accuracy: 0.5ºC (typical of Type K) * Including the accuracy of an internal RJC• Accepts 16 types of thermocouple (JIS/IEC/DIN/ASTM/GOST R)• Sub-display indicates the voltage source value and span%.• Simulates other types of thermocouple with the mV source
function• Works as a thermometer to measure the output from the TC
sensor• Handles various source patterns (Step sweep/linear sweep/manual step/span check)
Specifications
Source Thermocouple : K, E, J, T, N, L, U, R, S, B, C, XK, A, D, G, PLATINEL2
mV DC : 90 mVMeasurement Thermocouple : K, E, J, T, N, L, U, R, S, B, C, XK, A,
D, G, PLATINEL2 mV DC : 90 mVGeneral specifications • Dimensions : 90 (W) × 192 (H) × 42 (D) mm • Weight : Approx. 440 g • Power source : AA battery (LR6) × 4 or dedicated AC/DC
adaptor (option)
Bulletin: CA300-EN
High-performance Model Specialized for Simulating RTDsCA330RTD calibrator
• Basic accuracy: 0.3ºC (typical of PT100)• Accepts 14 types of RTD (JIS/IEC/GOST R)• Sub-display indicates the resistance source value and span%.• Accepts 2-, 3-, 4-wire systems and simulates RTDs precisely• Simulates other types of RTD with the resistance source function• Works as a thermometer to measure the output from the RTD
sensor• Handles various source patterns
(Step sweep/linear sweep/manual step/span check)
Specifications
Source RTD : PT100 (four types), PT200, PT500, PT1000, Cu10, Ni120, Extra RTD (five types)
Resistance : 500 Ω/3000 ΩMeasurement RTD : PT100 (four types), PT200, PT500,
PT1000, Cu10, Ni120, Extra RTD (five types)
Resistance : 500 Ω/3000 ΩGeneral specifications • Dimensions : 90 (W) × 192 (H) × 42 (D) mm • Weight : Approx. 440 g • Power source : AA battery (LR6) × 4 or dedicated AC/DC
adaptor (option)Bulletin: CA300-EN
Spare parts
Optional accessories (sold separately)
Product
Model 98020
Source signal lead cable
RD031
Measurement lead cable Carrying case
99021
Terminal adapter
93016
Product
Model
Remarks
94013120 V AC
94016-F220 to 240 V AC
VDE standard
94016-S220 to 240 V AC
BS standard
AC adapter
B9108WAFor reference junction
compensation
RJ sensor
B9108XALead cables, RJ sensor, etc.
can be stored
Accessory storage case
91017D-sub 9-pin (female)
Communication cable (RS232)
64
Cal
ibra
tor
Calibrator
64
Features
• Loop check functions • Simultaneous 24 V loop power and mA measurement • HART/BRAIN mode setting with loop power (Adds 250 ohm resistance internally)• Generation functions • SIMULATE (SINK) function simulates transmitters • 4-20 mA span/step/auto-step/sweep output• Measurement functions • High accuracy signal measurement:DC mA 0.05%/30.000 mA • Handheld DMM function • Peak Hold function for the peak voltage measurement of DCS power
supply • Dedicated sensor modes for direct reading of many sensor signal types• Enhanced Safety—helps eliminate electric shocks • Current terminal shutter prevents incorrect connections • 1 A or more of AC/DC current can be read directly using the optional
clamp probe and scaling in SENSOR mode.*1 • Measurement categories 600 V CAT. IV, 1000 V CAT. III *1: AC/DC 600 mV range only
Loop Power and 4 to 20 mA Output function in a DMM
CA450Process Multi Meter
Specifications
General Specifications
Specificaton• Display : 5-digit (7 Segment) Measurement DC current 33000, Frequency 19999, Other 6600 Output DC current 25000• Operating temperature and humidity: -20 to 55°C (80%RH or less) with no
condensation• Storage temperature and humidity: -40 to 70 (70%RH or less) with no
condensation • Battery life: DC voltage measurment: Appox.140 hours DC current output (SIMULATE) Approx.140 hours DC current output (SOURCE) 12 mA (500 Ω load) Approx.10 hours• External dimensions: Approx. 90 (W) × 192 (H) × 49 (D) mm• Weight: Approx. 600 g (including the batteries)• Compliant standards:• Safety standards: EN61010-1 and EN61010-031
Measurement Categories:1000 V CATIII, 600 V CATIVFor current measurement and output: 48 V max, 100 mA maxLead cables (98064): 70 VDC, 100 mAPollution degree 2, indoor useVibration: Sweep vibration frequencies 10 Hz to 5 Hz to 10 Hz Amplitude 0.15 mm (peak value)Duration 30 minutesShock: 1 m drop test as defined by the safety standardsAltitude: 2000 m or lessEMC standards: EN61326-1 Class B, EN61326-2-2 EN55011 Class B Group 1Influence of radiated immunity: In RF electromagnetic fields of 3 V/mEN61326-1 AC voltage measurement, 600 mV range:1.5% of rangeDC voltage measurement, 600 mV range:1% of rangeDC current measurement, all ranges: 1.5% of rangeDC current output: 1.5% of rangeEN61326-2-2 AC voltage measurement (6 V range or higher): Within 5 times the accuracyDC voltage measurement (6 V range or higher): Within 5 times the accuracy
Measurement
Function Range Resolution Max Accuracy
DCV600 mV/6 V/60 V/600 V/1000 V
0.1 mV/0.001 V/0.01 V/0.1 V/1 V 0.09%+2 digits
ACV 0.1 mV/0.001 V/0.01 V/0.1 V/1 V 0.5%+5 digits
DCA 30 mA/60 mA 0.001 mA/0.01 mA 0.05%+2 digits
Resistance600 Ω/6 kΩ/60 kΩ/600 kΩ/6 MΩ /60 MΩ
0.1 Ω/0.001 kΩ/0.01 kΩ/0.1 kΩ0.001 MΩ/0.01 MΩ
0.2%+2 digits
10Hz to 199.99 Hz 0.01 Hz
0.005%+1 digitsFreq 90Hz to 1999.9 Hz 0.1 Hz
0.900 kHz to 19.999 kHz 0.001 kHz
Source
DCmA 20 mA 0.001 mA 0.05% of range
Loop Power 24 V24 VDC (typ.)
Load current 20 mA
Other Functions and Spection
Functions Diode check, Continutity check, Data Hold, Peak Hold, Step mode, linear mode, Sesor mode, MIN/MAX, RELΔ%
Accessories
Test leads
Model:98073
Lead Cables
Model:98064
Fuse
Model:99042DMM Communication Package
92015 (*1)
Alligator
Test leads
Model:99014
AC/DC
Clamp-on Probe
Model:96095
Current
Clamp-on Probe
Model:96001
Carrying Case
Model:93029
Magnet hook
Model:99032
The Magnet hook
can be attached
to magnetic body
(e.g. iron).
The inner case
with detachable
straps can be
hung on bar.
Carrying Case
Model:93043-P1
(*1) Settings for output is not capable.
65
Cal
ibra
tor
Calibrator
High-end Model for Measuring Power Consumption and Power Quality
Clamp Power Meter CW500
CW500Power quality analyzer
• Achieves various power measurements with simple operations - One press on direct keys switches to any of five measurement displays.• Identifies power source malfunctions - Sampling with a 24-μs resolution can identify temporary malfunctions. - Measures harmonics and flickers• User support - Easy wiring and setting with the start navigation function and automatic detection of
clamp-on probes• PC software for analysis and setting comes as standard. - Data can be compiled into graphs and reports with one click.
Specifications
Wiring connection: 1P2W (max. 4 systems), 1P3W (max. 2 systems), 3P3W 2 currents (max. 2 systems), 3P3W 3 currents, 3P4WInput: 3 channels for voltage, 4 channels for current,
2 channels for DC voltageRange: AC voltage 600.0/1000 V AC current 2000 mA to 3000 A (depending on a clamp-on probe) AC power 3000 W to 3000 kW (depending on a clamp-on probe) DC voltage 100.0 mV/1.000 V/10.00 VAccuracy: Voltage ±0.2%rdg ± 0.2%rng Current ±0.2%rdg ± 0.2%rng + accuracy of clamp-on probes Power ±0.3%rdg ± 0.2%rng + accuracy of clamp-on probes Effect of power factor ±1.0%rdg (reading at power factor 0.5 against 1.0)Measurement items: • Voltage, current, frequency, power factor, effective/reactive/
apparent power • Consumption/generation of effective/apparent power,
delay/progress of reactive power • Demand, maximum demand, load factor, estimated demand value • Temporary malfunction: voltage swell, voltage dip, voltage
interrupt, transient overvoltage, inrush current • Continuous malfunction: components of up to the 50th harmonic
(RMS, content rate, and phase angle of voltage, current, and power), total harmonic distortion rate, IEC flicker, voltage unbalance rate, current unbalance rate
Measurement display: measurement values, trend graphs for all or each channel from the start of measurement, measured demand values, demand trend over a specific period or a whole period
Record interval: 1/2/5/10/15/20/30 sec, 1/2/5/15/20/30 min, 1 h/2 hGeneral specification: Dimensions: 120 (W) × 175 (H) × 68 (D) mm Weight: Approx. 900 g (including batteries) Power source: 100 to 240 V AC /50 to 60 Hz/alkaline AA battery ×
6/power supply adaptor (option)Accessories: Voltage probe, USB cable, power cord, carrying bag, SD card,
startup guide, alkaline AA battery × 6, input terminal plate × 6, PC software
Clamp power meter 96060 series
Bulletin: CW500-EN
Clamp-on probes for the CW500 power meterModel code 96060 96061 96062 96063 96064 96065 96066
Clamp-on probe
Measurable diameter
ϕ40 mm ϕ18 mm ϕ24 mm ϕ30 mm ϕ40 mm ϕ110 mm ϕ150 mm
Measuring range 2 A AC 50 A AC 100 A AC 200 A AC 500 A AC 1000 A AC300 A AC1000 A AC3000 A AC
Output voltage 50 mV AC (25 mV/A) 500 mV AC (10 mV/A) 500 mV AC 500 mV AC 500 mV AC 500 mV AC500 mV ACFor each range
Accura
cy Leve
l
50 Hz/60 Hz
±1.0% rdg ±0.05 mV
±0.5% rdg ±0.1 mV
±0.5% rdg ±0.1 mV
±0.5% rdg ±0.1 mV
±0.5% rdg ±0.1 mV
±0.8% rdg ±0.2 mV
±1.0% rdg*
40 Hz to 1 kHz
±2.0% rdg ±0.1 mV
±0.8% rdg ±0.2 mV
±1.0% rdg ±0.2 mV
±0.8% rdg ±0.2 mV
±1.0% rdg ±0.2 mV
±1.5% rdg ±0.4 mV
—
1 kHz to 3.5 kHz
±3.0% rdg ±0.2 mV
±1.0% rdg ±0.4 mV
—±1.0% rdg ±0.4 mV
— — —
Accuracy Degree
—Less than ±2.0° (0.5 to 50 A, 40 Hz to 3.5 kHz)
Less than ±2.0° (1 to 100 A, 45 Hz to 65 Hz)
Less than ±1.0° (2 to 200 A, 40Hz to 3.5kHz)
Less than ±1.0° (5 to 500 A, 45 Hz to 65 Hz)
Less than ±2.0° (45 Hz to 65 Hz)Less than ±3.0° (40 Hz to 1 kHz)
Less than ±1.0° (for each range/45 to 65 Hz)
Max Circuit voltage
AC 300 Vrms AC 300 Vrms AC 300 Vrms AC 600 Vrms AC 600 Vrms AC 600 Vrms AC 600 Vrms
Dimensions 70 × 120 × 25 mm 52 × 106 × 25 mm 60 × 100 × 26 mm 73 × 130 × 30 mm 81 × 128 × 36 mm 73 × 130 × 30 mm 61 × 111 × 43 mm
Weight Approx. 250 g Approx. 170 g Approx. 160 g Approx. 250 g Approx. 260 g Approx. 170 g Approx. 950 g
Remarks These probes are dedicated for the CW500 and cannot be used for the CW240/CW120/CW121.
*45 to 65 Hz (measuring at the center of sensor)
66
Cla
mp-
onP
ower
Met
er
Clamp-on Power Meter
CW10Clamp-on Power Meter
A Powerful Power Measuring Tool
Features
• AC / DC Power up to 600 kW• True RMS for AC.• Harmonics 1st to 25th order• Power fluctuation using the ACA Inrush and Peak hold functions.• AC / DC Voltage max. 1000 V• AC / DC Current max. 600 A• Frequency, Resistance, Continuity, Diode check, Power factor.• Up to 9999 counts, approx. 37 mm max. diameter of measurable conductor (the jaw opens
approx. 45 mm max.)
Specifications
Accuracy23± 5ºC, 80%RH or lessAccuracy: ±(% of reading + digits)
Voltage Rms-value detection
Function RangeResolution
(Maximum reading)Accuracy*
DCV100 V 99.99 V
0.7% + 21000 V 999.9 V
ACV100 V 99.99 V 1.0% + 5
50 to 500 Hz1000 V 999.9 V
LPFACV
100 V 99.99 V 50 ≤ f ≤ 60 Hz: 1.0% + 560 < f ≤ 400 Hz: 5.0% + 51000 V 999.9 V
* DCV<1000 digits: add 6 digits to accuracy ACV<1000 digits: add 3 digits to accuracyMaximum input voltage: 1000 Vrms, 1414.2 VpkInput impedance: approx. 3.5 MΩ, <100 pFAC+DC Vrms accuracy=ACV accuracy + DCV accuracy
Crest factor effects1.4 < CF ≤ 2.0: add 1.0% of reading to accuracy2.0 < CF ≤ 2.5: add 2.5% of reading to accuracy2.5 < CF ≤ 3.0: add 4.0% of reading to accuracy
Maximum input voltage: 690 Vrms CF=2 460 Vrms CF=3
Current Rms-value detection
Function RangeResolution
(Maximum reading)Accuracy*
DCA100 A 99.99 A 1.5% + 20
600 A 600.0 A*** 1.5% + 5*
ACA100 A** 99.99 A 50 ≤ f ≤ 60 Hz : 1.5% + 5*
60 < f ≤ 400 Hz : 2.0% + 5*600 A 600.0 A***
LPFACA
100 A** 99.99 A 50 ≤ f ≤ 60 Hz : 1.5% + 560 < f ≤ 400 Hz: 5.0% + 5600 A 600.0 A***
*The measured value <1000 digits: add 5 digits to accuracy**Input current ≥ 0.10 A at 100 A range of ACA and LPF ACA***600 A : Guaranteed accuracy (not maximum reading)Maximum input current: 600 Arms, 848.5 ApkConductor position effects: ±1.0% of readingAC+DC Arms accuracy=ACA accuracy + DCA accuracy
Crest factor effects1.4 < CF ≤ 2.0: add 1.0% of reading to accuracy2.0 < CF ≤ 2.5: add 2.5% of reading to accuracy2.5 < CF ≤ 3.0: add 4.0% of reading to accuracy
Maximum input current: 420 Arms CF=2 280 Arms CF=3
Peak Hold (AC mode only)
Function RangeResolution
(Maximum reading)Accuracy
ACV100 V 140.0 V
3.0% + 151000 V 1400 V
ACA100 A 140.0 A
3.0% + 15600 A 850 A
PEAK MAX: polarity+, polarity-Maximum input voltage and current: 1000 Vrms, 600 ArmsSine wave, ACV ≥ 5 Vrms, ACA ≥ 5 Arms, 50 to 400 Hz continuous wave
Frequency (Hz)
Function Resolution (Measuring range) Accuracy
100 Hz 20.00 to 99.99 Hz
0.5% + 31000 Hz 20.0 to 999.9 Hz
10 kHz 0.020 to 9.999 kHz
Maximum input voltage and current: 1000 Vrms, 600 Arms
Input condition; 100 V range: 10 to 100 Vrms
(Sine wave) 1000 V range: 100 to 1000 Vrms
100 A range: 10 to 100 Arms (<400 Hz)
600 A range: 100 to 600 Arms (<400 Hz)
The measured value < approx. 10 Hz: 0.00 Hz
Harmonic MeasurementIndividual Harmonic
Harmonic order Resolution (Maximum reading) Accuracy
1st to 12th (h01- h12)99.9%
5% + 10
13th to 25th (h01- h12) 10% + 10
Maximum input voltage and current: approx. 1000 Vrms, 600 Arms
The “rdy” is displayed at ACV < 10 Vrms, ACA < 10 Arms
The “OutF” is displayed at f < 45, 65 < f (f: fundamental frequency)
Inrush Current
Function RangeResolution
(Maximum reading)Accuracy
ACA100 A 99.99 A 2.5% + 20
600 A 600.0 A* 2.5% + 5
Maximum input current: approx. 600 Arms*600 A : Guaranteed accuracy (not maximum reading)100 A range: ACA1 ≥ 10 Arms (Sine wave, 50 Hz/60 Hz)
600 A range: ACA ≥ 100 Arms (Sine wave, 50 Hz/60 Hz)Measurement time: approx. 100ms
Active Power
Function RangeResolution
(Maximum reading)Accuracy
ACWDCW
10 kW 9.999 kW*ACW: 2.5% + 11**DCW: 2.2% + 22**
100 kW 99.99 kW
600 kW 600.0 kW**
* The measured value < 1.000 kW: add 10 digits to the accuracy.
**Conditions of accuracy (combination of Voltage and Current range)10 kW range: 100 V and 100 A100 kW range: 100 V and 600 A or 1000 V and 100 A600 kW range: 1000 V and 600 AOther combinations:Accuracy: (Current accuracyVoltage reading) + (Voltage
accuracyCurrent reading)
**600 kW : Guaranteed accuracy (not maximum reading)Maximum input voltage and current: 1000 Vrms, 600 ArmsACW: ACV ≥ 10 Vrms and ACA ≥ 5 Arms (Sine wave, 50 ≤ f ≤ 60 Hz, PF=1.00)DCW: at DCV ≥ 10 V and DCA ≥ 5 A
Power Factor
Function Resolution (Measuring range) Accuracy
Power factor -1.00 to 0.00 to 1.00 ±(3º+2digits)
Maximum input voltage and current: 1000 Vrms, 600 Arms
PF: ACV ≥ 10 Vrms and ACA ≥ 5 Arms (Sine wave, 50 ≤ f ≤ 60 Hz)
Resistance/Continuity check
Function RangeResolution
(Maximum reading)Accuracy
Resistance Ω1000 Ω 999.9 Ω 1.0% + 5
10 kΩ 9.999 kΩ1.0% + 3
100 kΩ 99.99 kΩ
Continuity check1000 Ω 999.9 Ω 1.0% + 5
The buzzer turns on for resistances lower than approx. 30 Ω. (Response time: approx. 100 msec)
Maximum input voltage: 1000 VrmsMaximum test current: approx. 0.5 mAOpen circuit voltage: approx. 3 V
Diode Test
Function Resolution (Measuring range) Accuracy
Diode Test 0.40 to 0.80 V ±0.1 V
Maximum test current: approx. 0.5 mA
Open circuit voltage: approx. 1.8 V
General SpecificationsDisplay count: 9999 / 6000
Measuring rate: 3 times / sec.
Over range indicator: “OL” or “-OL”
Auto Power Off: Approx. 15 minute.
Low-battery indicator: (four steps)
Power supply: 9 V alkaline battery (6LR61)
Battery life: When using alkaline battery, backlight off
Approx. 20 hours
Operating temperature and humidity: 0 to 50˚C (with no condensation)
≤ 80% RH (0 to 30˚C)
≤ 75% RH (30 to 40˚C)
≤ 45% RH (40 to 50˚C)
Temperature coefficient: At 0 to 18 ˚C and 28 to 50˚C
Add 23±5 ˚C accuracy x 0.2 /˚C
Storage temperature: -10 to 50 ˚C, 80% RH or less (remove the battery)
Withstand voltage: AC 6880 Vrms 5 sec. (between the core and the case)
AC 4300 Vrms 5 sec. (between the core and the voltage input terminals)
AC 6880 Vrms 5 sec. (between the voltage input terminals and the case)
Insulation resistance: 100 MΩ or greater at 1000 VDC
(between the core and the case, the core and the voltage input
terminals and the voltage input terminals and the case)
Compliant standards:
Safety standards: EN 61010-1, EN 61010-2-032
1000V CAT.III, 600V CAT.IV
EN 61010-031 (the test leads)
Pollution degree 2, Indoor use, Altitude 2000m or less
EMC standards: EN 61326-1, EN 61326-2-1, EN 61326-2-2, EN 55011
Dimensions: Approx 87.5 mm(W) × 242 mm(L) × 51 mm(D)
Diameter of measurable conductors: ϕ 37mm (Maximum)
Weight: Approx. 435 g (including the battery)
Accessories: Test leads 1 set (Red and Black)
Carrying case
9 V alkaline battery (6LR61)
User’s Manual
Accessories (Sold Separtely): Lead with Alligator Clip Model code 99014
68
Dig
ital M
ultim
eter
Digital Multi Meter
7533
serie
s
7534
serie
s
3.5 Digits4.5 Digits
TY720
TY710
TY530
TY520
73201
73202
73203
73101
Existing
model
Disco
ntin
ued
prod
ucts
for r
epla
cing
7340
1
7310
1
7532
01
7532
02
7532
03
7537
01
7537
02
7537
03
7537
04
7538
01
7330
3
7330
2
7330
1
7544
01
7544
02
7340
2
Handheld Digital Multi Meter Sellection
Simple selection for replacing discontinued products
Handhel Digital Multi Meter Models
Function item TY710 TY720 TY520 TY530 73201 73202 73203 73204 73101
Measurment Function Ture RMSTure RMS MEAN
SellectRMS
RMS MEAN
SellectMEAN MEAN MEAN MEAN MEAN
Max. Measurrement Accuracy at DCV 0.02% 0.09% 0.5% 0.5% 0.3% 0.5% 0.7%
Wide bandwidth 20 KHz 100 KHz 1 kHz — —
Display Digits(Uint:Digit) 5 digits 3.5 Digits 3.5 Digits 3.5 Digits
Max. Value 50000 6000 4300 4300
Bar Graph Dsiplay (Uints:Segment) 51 31 — 32
LCD Back Light White LED LED — —
Max.Measurement Voltage (AC/or DC)
50.000 mV
to
1000.0 V
50.000 mV
to
1000.0 V
600.0 mV
to
1000 V
600.0 mV
to
1000 V
4.000 V*3
to
600 V
4.000 V*3
to
600 V
4.000 V*3
to
600 V
4.000 V*3
to
600 V
4.000 V*3
to
600 V
Max.Measurement Currents (AC/or DC)
500.00 μA
to
10.000 A
500.00 μA
to
10.000 A
600.0 μA
to
10.00 A
600.0 μA
to
10.00 A
400.0 μA
to
10.00 A
400.0 μA
to
10.00 A
400.0 μA
to
10.00 A
— —
Max.Measurement Resistance
500.00 Ωto
50.000 MΩ
500.00 Ωto
50.000 MΩ
600.0 Ω
to
60.00 MΩ
600.0 Ω
to
60.00 MΩ
400.0 Ωto
40.00 MΩ
400.0 Ωto
40.00 MΩ
400.0 Ωto
40.00 MΩ
400.0 Ωto
40.00 MΩ
400.0 Ωto
40.00 MΩ
Max.Measurement Frequency
2.000 Hz
to
99.99 kHz
2.000 Hz
to
99.99 kHz
10.00 Hz
to
99.99 kHz
10.00 Hz
to
99.99 kHz
— — — — —
Max.Measurement Capcitance
5.000 nF
to
50.00 mF
5.000 nF
to
50.00 mF
10.00 nF
to
1000 μF
10.00 nF
to
1000 μF
—
20.00 nF
to
200.0 μF
20.00 nF
to
200.0 μF
— —
Max.Measurement Temperature +1372°C*1 +1372°C*1 +600°C*1 +600°C*1 — — — — —
Duty Ratio (%) Measuement — — — — — — —
Low-Power — — — — — — — —
AC+DC Measurement — — — — — — —
Max./Min./Ave. Value Memory — — — — — —
Diode Test
Continuity Check
Relative/Percentage (%) calculation — — — — —
Decibel calculation — — — — — —
Selection Auto range or Manual range —
Peak Hold — — — — — — — —
Data Hold *2
Auto Hold
Communication for PC *2 *2 — *2 — — — — —
Data Logging Memory *2 *2 — *2 — — — — —
Data Memory 1000 10000 — 1600 — — — — —
Operating Temp. and Humidity -20 to 55°C -20 to 55°C -10 to 55°C -10 to 55°C 0 to 50°C 0 to 50°C 0 to 50°C 0 to 50°C 0 to 50°C
Electric Safety 1000 V CAT III CAT III — —
Electric Safety 600 V CAT IV CAT IV CAT II CAT III CAT III
Electric Safety 300 V — — CAT III — CAT II
*1 Temperature probe is necessary when measuring temperature.*2 The communications package (model: 92015) for DMM is necessary when connecting it with PC. *3 73101,732 Series minimum range of DCvoltage is 400.0 mVDC.
69
Dig
ital M
ultim
eter
Digital Multi Meter
A New De Facto Standard for Handheld DMM
TY700 SeriesDigital Multimeters
• Maximum Measurement Accuracy: 0.020% rdg + 2 dgt • Highly Reliable: Closed case calibration• Full Support of Data Management: Measured data stored in internal memory• Safe Design: Shutters prevent erroneous insertion of test leads into current
measurementterminals (terminal shutters)
• Shockproof elastomer casing
• Wide operating temperature range: -20 °C to 55°C
General SpecificationsAdditional Functions USB communication (optional adapter & software),
data memory (TY720: 10,000 data, TY710: 1,000 data), max/min value memory, relative/percentage value computation, logarithm computation, data/auto hold, peak hold (TY720), overvoltage warning, backlight
Power Supply Four AA (R6) dry cellsBattery Life Approx. 120 hoursDimensions 90 (W) × 192 (H) × 49 (D) mmWeight Approximately 560 g (including batteries)Safety Standards 1000 V CAT. 3, 600 V CAT. 4
Features
• Data saved in the internal memory PC transfer is possible (Save memories or Logging Memories)• DMM measurements show in real time monitor display is possible.• Large amounts of data not covered by the internal memory PC communication with data transfer is possible. At the same time Excel transferable is also. Maximum incoming data: 32767
• Measurement data to Excel direct deployment is possible. Automatically creates a chart sheet.
DMM of dedicated application software (Model: 92015 )
DMM’s and you can easily manage the data in memory. Is also capable of real-time communications
92015 product specification:
Communication cableCommunications cable: infrared communication adapter +
communications cable (USB specifi-cations) 2 m length
Interface standards: USB specification conforms to the 1.1 Available models : TY710, TY720, TY530
Application software
Operating environment of the personal computerOS: Windows XP / Vista / 7 CPU: Pentium 133 MHz or higherMemory: 64 MB Hard disk has free space or more storage: 10 MB Over, CD drive Excel: since the Excel2000 Software: CD, communication cable (including adapter),
User’s manual
TY710 TY720
Detection RMS Switching detection (RMS or MEAN)
Item Range Accuracy
DCV
50 mV 0.05 + 10
500 mV/2400 mV 0.02 + 2
5 V 0.025 + 5
50 V/500 V/1000 V 0.03 + 2
ACV
[RMS]
Upper: 10 to 20 Hz
Lower: 20 Hz to 1 kHz
Upper: 1 kHz to 10 kHz
Lower: 10 kHz to 20 kHz
Upper: 20 kHz to 50 kHz
Lower: 50 kHz to 100 kHz
Upper: 10 to 20 Hz
Lower: 20 Hz to 1 kHz
Upper: 1 kHz to 10 kHz
Lower: 10 kHz to 20 kHz
Upper: 20 kHz to 50 kHz
Lower: 50 kHz to 100 kHz
50 mV—
—
—
—
—
—
2 + 80
0.4 + 40
5 + 40
5.5 + 40
15 + 40
15 + 40
50 mV/5 V/
50 V/500 V 1.5 + 30
0.7 + 30
0.7 + 30
2 + 50
—
— 1 + 30
0.4 + 30
0.4 + 30
1 + 40
2 + 70
5 + 200
1000 V3 + 30
—
—
—
3 + 30
—
—
—
ACV
[MEAN]
10 to 20 Hz 20 Hz to 500 Hz 500 Hz to 1 kHz
50 mV — 4 + 80 1.5 + 30 5 + 30
50 mV/5 V/
50 V/500 V/1000 V— 2 + 30 1 + 30 3 + 30
DCV + ACV
Upper: DC, 10 to 20 Hz
Lower: DC, 20 Hz to 1 kHz
Upper: DC, 1 kHz to 10 kHz
Lower: DC, 10 kHz to 20 kHz
Upper: DC, 20 kHz to 50 kHz
Lower: DC, 50 kHz to 100 kHz
Upper: DC, 10 to 20 Hz
Lower: DC, 20 Hz to 1 kHz
Upper: DC, 1 kHz to 10 kHz
Lower: DC, 10 kHz to 20 kHz
Upper: DC, 20 kHz to 50 kHz
Lower: DC, 50 kHz to 100 kHz
5 V/50 V/500 V1.5 + 10
1 + 10
1 + 10
2 + 10
—
—
1.5 + 10
0.5 + 10
0.5 + 10
1 + 10
2 + 10
5 + 20
1000 V1.5 + 10
1 + 10
—
—
—
—
1.5 + 10
0.5 + 10
—
—
—
—
DCA
500 μA/5000 μA/
50 mA/500 mA0.2 + 5
5 A 0.6 + 10
10 A 0.6 + 5
ACA
[RMS]
10 Hz to 20 Hz 20 Hz to 1 kHz 1 kHz to 5 kHz 10 Hz to 20 Hz 20 Hz to 1 kHz 1 kHz to 5 kHz
500 μA/5000 μA/
50 mA/500 mA 1.5 + 20 1 + 20 —1 + 20 0.75 + 20 1 + 30
5 A/10 A 1.5 + 20 1 + 20 2 + 30
ACA
[MEAN]
10 Hz to 20 Hz 20 Hz to 1 kHz 1 kHz to 5 kHz
500 μA/5000 μA/
50 mA/500 mA— 2 + 20 1.5 + 20 2 + 30
5 A/10 A — 3 + 20 2 + 20 4 + 30
DCA + ACA
DC, 10 to 20 Hz DC, 20 Hz to 1 kHz DC, 1 kHz to 5 kHz DC, 10 to 20 Hz DC, 20 Hz to 1 kHz DC, 1 kHz to 5 kHz
500 μA/5000 μA/
50 mA/500 mA 2 + 10 1.5 + 10 —1.5 + 10 1 + 10 1.5 + 10
5 A/10 A 2 + 10 1.5 + 10 3 + 10
Resistance
500 Ω/5 kΩ/50 kΩ500 kΩ 0.1 + 2 0.05 + 2
5 MΩ 0.5 + 2
50 MΩ 1 + 2
Low-power
Resistance
5 kΩ/50 kΩ/500 kΩ — 0.2 + 3
5 MΩ — 1 + 3
Frequency 2.0 Hz to 99.99k Hz 0.02 + 1
Capacitance
5 nF/50 nF/500n F
5 μF/50 μF1 + 5
500 μF 2 + 5
5 mF/50 mF 3 + 5
Continuity check 550 Ω Buzzer sounds at 100±50 Ω or less
Diode test 2.4 V 1 + 2
Temperature -200 to 1372°C 1 + 1.5°C
70
Dig
ital M
ultim
eter
Digital Multi Meter
73101Pocket Digital Multimeter
4300 count displayContinuity Check and Diode TestAuto HoldAuto Power Off
73101 Specifications
Accuracy: (23°C ±5°C, Less than 80% RH), ±(% rdg + dgt)
Pocket DMM with Superb Portability
732 SeriesDigital Multimeters
3.5 digits (4,300-count), Mean value typeMeasurement Functions: Voltage, Current, Resistance, Continuity Check, Diode Test, CapacitanceFeatures: Auto hold, Auto power-off
Low-cost Handheld DMM
Provides Safety Levels Demanded in Field Work
Model 73201 73202 73203 73204
Detection Mean value
Item Range Accuracy
DCV400.0 mV/4.000 V/40.00 V/400.0 V/600 V
0.5% + 10.75% + 1
0.5% + 1 0.3% + 1 0.5% + 1
ACV4.000 V/40.00 V/400.0 V/600 V
1.0% + 5 0.75% + 5
DCA400.0 μA/4000 μA/40.00 mA/400.0 mA/10.00 A
1.0% + 22.0% + 2
−
ACA(40 to 500 Hz)
400.0 μA/4000 μA/40.00 mA/400.0 mA/10.00 A
2.0% + 202.0% + 52.0% + 202.0% + 52.0% + 20
−
Resistance400.0 Ω/4.000 kΩ/40.00 kΩ/400.0 kΩ/4.000 MΩ/40.00 MΩ
0.75% + 20.75% + 12.0% + 15.0% + 2
Item Range Accuracy Input Resistance
DCV400.0 mV4.000 V
40.00/400.0/600 V
1.2% + 20.7% + 11.2% + 1
>100 MΩ11 MΩ10 MΩ
ACV4.000 V
40.00/400.0/600 V2.0% + 5 10 MΩ
Resistance
400.0 Ω4.000 k/40.00 k/400.0 kΩ
4.000 MΩ40.00 MΩ
1.2% + 22.0% + 35.0% + 3
Continuity check 400.0 Ω −
Diode test 2.00 V 1.5% + 1Open-circuit Voltage<3.4 V
Testing Current<1.0 mA
General Specifications • External dimensions: 74 (W) × 155 (H) × 31 (D) mm • Weight: Approx. 240 g • Power Supply: Two AAA (LR03 or R03) dry cells
732 Series Specifications
Accuracy: (23°C ±5°C, Less than 80% RH), ±(% rdg + dgt)
Genetal Specifications • External dimensions: 76 (W) × 117 (H) × 18 (D) mm • Weight : Approx. 110 g • Power Supply: Two LR-44 dry cells
TY500 SeriesDigital Multimeters
3.5 digits (6,000-count, 31-segment bar graph display), RMS typeMeasurement Functions: Voltage, Current, Resistance, Continuity Check, Diode Test, Frequency, Capacitance, TemperatureFeatures: Closed case calibration, Hi-impact overmold case, USB communication (optional adapter & software) (TY530 only), data memory (1,600 data for TY530 only)Safety Standards: 1000 V CAT. 3, 600 V CAT. 4
General Specifications • External dimensions: 90 (W) × 192 (H) × 49 (D) mm • Weight : Approx. 570 g • Power Supply: Four AA (R6) dry cells
TY500 Series Specifications
Accuracy: (23°C ±5°C, Less than 80% RH), ±(% rdg + dgt)
TY520 TY530
Detection RMS Switching detection (RMS or MEAN)
Item Range Accuracy
DCV
600 mV/6 V/60 V/600 V
0.09 + 2
1000 V 0.15 + 2
ACV
50/60 Hz 40 to 500 Hz 500 Hz to 1 kHz
600 mV/6 V/60 V/600 V1000 V
0.5 + 5 1 + 51.5 + 5
—
DCA600 μA/6000 μA/60 mA 0.2 + 2
600 mA/6 A/10 A 0.5 + 5
ACA
50/60 Hz 40 Hz to 1 kHz
600 μA/6000 μA/60 mA/600 mA/6 A/10 A
0.75 + 5 1.5 + 5
Resistance
600 Ω/6 kΩ/60 kΩ/600 kΩ 0.4 + 1
6 MΩ 0.5 + 1
60 MΩ 1 + 2 (0 to 40 MΩ)2 + 2 (40 to 60 MΩ)
Frequency 10.0 Hz to 99.99 kHz 0.02 + 1
Capacitance
10 nF 2 + 10
100 nF/1 μF/10 μF 2 + 5
100 μF/1000 μF 3 + 5
Continuity check 600 Ω Buzzer sounds at 50±30 Ω or less
Diode test 2 V 1 + 2
Temperature -50 to 600°C 2 + 2°C
71
Dig
ital M
ultim
eter
Digital Multi Meter
93029
RD031
323
110 50 10
1200 50
ϕ 3.2 ϕ
22
ϕ 14
90050200
50 10
1200
ϕ 1
.6 ϕ 22
ϕ 14
150
273
110
9005150
26
14
30 110
178
6
50 10
1200
ϕ 15
ϕ 6.0
ϕ 14
9005550
13.5
177.5
30 110 50 1025.5
5.5
1200
ϕ 15
ϕ 6.0
ϕ 14
90056
96095
9807392015
Specifications
96095Model
ϕ 12mm
AC10 mV/A(AC 1 to 1300 mVrms)50/60 Hz
1.2% + 0.4 mV
-30 to 70°C relative Humidity 85% or less (no condensation)
Low battery warning: 2.2 V±0.2 V or less red LED flash1.9 V±0.2 V or less Power off
Approx. 35 Hours till a low battery indicator flashes*1
Dimensions&Weight127 (L) × 42 (W) × 22 (D) mm
Cord length: Approx.1200 mm Weight: Approx 140 g
EN61010-1: CAT3Pollution degree2, Altitude 2000 m or less for indoor use
EN61326-1: ClassB,EN61326-2-032
*1 From low battery warning to power off is about 5hours
Conductor Size
Measurement range
AC 0.1 to 130 A
DC 0 to ±180 A
General specifications
Output voltage Accuracy (at 23°C±5°C)
Operating Temp&Humidity range
Storage Temp&Humidity range
Power source
DC3 V(Size AAA alkaline Battery LR03 × 2 pcs)
Continuous use
Applicable standards
Accessories Soft case(94030),Battery,User’s Manual
-10 to 55°C relative Humidity 85% or less (no condensation)
2.5% + 0.4 mV
40 Hz to 1 kHz
1.2% + 0.4 mVDC10 mV/A (DC 0 to ±1800 mV)
96095AD/DC Clamp-on Probe
• Light and compact, easy to carry and easy to clamp on crowded wirings.
• Expands measuring span of currents and assure safety when measuring with any kind of DMM.
96001
Standerd Accessories
Applicable DMM Models
TY700 TY500 732
Name Model Specification TY710 TY720 TY520 TY530 01 02 03 04
Communication Package forDigital Multimeters
92015 Communication Adapter for USB+cable+Application Software
Test leads with Alligator Clip 990141000V CAT# 600V CAT$Red/Black(1 set)
Alligator Clips B9646HF Red/Black(1 set)
Rubber Case 93007
Carrying Case 93029 Hard case
B9646GB Hard case
Temperature Probe (Thermocouple type K)(Banana plag output)
90050 -50 to 150°C for liquld
90051 -50 to 600°C for liquld
90055 -20 to 250°C for surface
90056 -20 to 500°C for surface
Currents Clamp-on probe 96001 For 400 AAC Output: AC10 mV/A*1
96095For 130 AAC/180 ADCOutput: AC10 mV/A or DC10 mV/A*2
*1 Please use it with the ACV range. It is necessary to read the indicated value in a different way as TY710 and the TY720,732 series. The example: In AC1V display = 100 A TY520 and TY530, it is possible to scale it. (Even 60 A or less display is possible in case of 96001. )*2 Please use it with ACV or DCV range. It is necessary to read the indicated value in a different way as TY710 and the TY720,732 series. The example: In AC1V display = 100 A TY520 and TY530, it is possible to scale it. (Even 60 A or less display is possible in case of 96095. )
Applicable DMM Models
TY700 TY500 732
Name Model Specification TY710 TY720 TY520 TY530 01 02 03 04
Test leads 98073 1000V CAT# 600V CAT $ Red/Black(1set)
RD031 L-plug, Red/Black(1 set)
Fuse 99015 440 mA/1000 V
99016 10 A/1000 V
F02 15 A/250 V
F05 500 mA/250 V
Accessorise
DMM Accessories
Cla
mp-
on T
este
r
72
Clamp-on Tester
CL220Clamp-on Tester
• ACA/DCA• ϕ 24• AC/40 to 300 A• DC/40 to 300 A
AC/DC Current Measurement
CL150/CL155Clamp-on Testers
• ACA• ϕ 54• AC/400 to 2000 A• AC V/DC V/Ω• DC Output• RMS for CL155
Wide Range of Current Measurement
ACA
ACV
DCV
Resistance
Item Range
400 A
2000 A (0 to 1500 A)
2000 A (1500 to 2000 A)
40/400/750 V
40/400/1000 V
400/4 k/40 k/400 k
1.0 + 3 (50/60 Hz)
2.0 + 3 (40 to 1 kHz)
1.0 + 3 (50/60 Hz)
3.0 + 3 (40 to 1 kHz)
3.0 (50/60 Hz)
1.0 + 2 (50/60 Hz)
1.5 + 3 (40 to 1 kHz)
1.0 + 2
1.5 + 2, Beep sound at less than 50 ±35
Accuracy
Accuracy: (23°C ±5°C, Less than 75% RH), ±(% rdg + dgt)
ACA
DCA
Item Range
40 A
300 A (20 to 200 A)
300 A (200 to 300 A)
40 A
300 A (20 to 200 A)
300 A (200 to 300 A)
1.0 + 4
1.5 + 4
3.0
1.0 + 4 (50/60 Hz)
2.5 + 4 (20 to 1 kHz)
1.5 + 4 (50/60 Hz)
2.5 + 4 (20 to 1 kHz)
3.5 (50/60 Hz)
4.0 (20 to 1 kHz)
Accuracy
Accuracy: (23°C ±5°C, Less than 85% RH), ±(% rdg + dgt)
CL150/CL155 Specifications CL220 Specifications
CL130/135Clamp-on Testers
• ACA• ϕ 33• AC/200 to 600 A• AC V/Ω• RMS for CL135
AC/DC Current Measurement
CL120Clamp-on Tester
• ACA• ϕ 24• AC/20 to 200 A
Light weight & compact design
ACA
Item Range
20 A
200 A
2.0 + 7 (50 to 1 kHz)
2.0 + 5 (50/60 Hz)
3.0 + 10 (40 to 1 kHz)
Accuracy
Accuracy: (23°C ±5°C, Less than 75% RH), ±(% rdg + dgt)
ACA
ACV
Resistance
Item Range
200 A
600 A
200 V/600 V
200 Ω
1.5 + 6 (50/60 Hz)
2.0 + 5 (40 to 1 kHz)
1.0 + 3 (50/60 Hz)
2.0 + 5 (40 to 1 kHz)
1.0 + 2 (50/60 Hz)
1.5 + 4 (40 to 1 kHz)
1.2 + 4, Beeps at below 30 Ω (continuity check)
1.5 + 4 (50/60 Hz)
2.0 + 5 (40 to 1 kHz)
1.5 + 4 (50/60 Hz)
2.0 + 5 (40 to 1 kHz)
1.0 + 2 (50/60 Hz)
1.5 + 4 (40 to 1 kHz)
Accuracy (CL130/CL135)
Accuracy: (23°C ±5°C, Less than 85% RH), ±(% rdg + dgt)
CL120 Specifications CL130/CL135 Specifications
ModelDiameter of measurable
conductorRange Accuracy
AC
curr
ent
DC
curr
ent
Leak c
urr
ent
DC
volta
ge
AC
volta
ge
Resi
sta
nce
Contin
uity
check
Fre
quency
True R
MS
Outp
ut
Data
hold
Peak h
old
Filt
er
CL120 ϕ 24 20 to 200 A 2.0 + 7
CL130 ϕ 33 200 to 600 A 1.5 + 6
CL135 ϕ 33 200 to 600 A 1.5 + 4
CL150 ϕ 54 400 to 2000 A 1.0 + 3
CL155 ϕ 54 400 to 2000 A 1.0 + 3
CL220 ϕ 24 400 to 300 A 1.0 + 4
CL235 ϕ 33 400 to 600 A 1.0 + 5
CL250 ϕ 55 400 to 2000 A 1.5 + 2
CL255 ϕ 55 400 to 2000 A 1.5 + 2
CL320 ϕ 24 20 mA to 200 A 2.0 + 4
CL340 ϕ 40 40 mA to 400 A 1.0 + 5
CL345 ϕ 40 40 mA to 400 A 1.0 + 5
30031A ϕ 40 3 mA to 60 A 1.0 + 5
30032A ϕ 40 3 mA to 60 A 1.0 + 5
CL360 ϕ 68 200 mA to 1000 A 1.0 + 2
CL420 ϕ 6 DC 20 to 100 mA 0.2 + 3
Cla
mp-
on T
este
r
73
Clamp-on Tester
Leakage Currents of 1 mA measurement
CL250/CL255Clamp-on Testers
• ACA/DCA• ϕ 55• AC/400 to 2000 A, DC/400 to 2000 A• AC V/DC V/Ω• DC Output• Hz, RMS for CL255
Wide Range of ACA/DCA measurement
CL235Clamp-on Tester
• ACA/DCA• ϕ 33• AC/400 to 600 A, DC/400 to 1000 A• AC V/DC V/Ω/Hz• RMS
RMS ACA/DCA measurement
ACA
DCA
ACV
DCV
Resistance
Frequency
Item Range
400/600 A
400/1000 A
40/400/600 V
40/400/600 V
400/4000 Ω10 to 3000 Hz
1.5 + 5 (50/60 Hz)
3.5 + 5 (40 to 1 kHz)
1.0 + 5
1.5 + 5 (50/60 Hz)
3.5 + 5 (40 to 1 kHz)
1.0 + 5
1.0 + 5, Beeps at below 20 Ω (continuity check)
1.5 + 5
Accuracy
Accuracy: (23°C ±5°C, Less than 75% RH), ±(% rdg + dgt)
DCA
ACA
Item Range
400/2000 A
400 A/2000 A (0 to 1000 A)
2000 A (1001 to 2000 A)
1.5 + 2
1.5 + 2 (50/60 Hz)
3.0 + 4 (40 to 500 Hz)
5.0 + 4 (500 to 1 kHz)
3.0 + 2 (50/60 Hz)
Accuracy
Accuracy: (23°C ±5°C, Less than 75% RH), ±(% rdg + dgt)
CL235 Specifications CL250 Specifications
CL320Leakage Clamp-on Tester
• ACA• ϕ 24• AC/20 mA to 200 A
Compact design of Leakage current measurement
ACA
Item Range
20 mA/200 mA
200 A (0 to 100 A)
200 A (100.1 to 200 A)
2.0 + 4 (50/60 Hz)
5.0 + 6 (40 to 400 Hz)
5.0 + 4 (50/60 Hz)
3.0 + 5 (50/60 Hz)
5.0 + 5 (50/60 Hz)
Accuracy
WIDE (40 to 400 Hz) 50/60 Hz
Accuracy: (23°C ±5°C, Less than 85% RH), ±(% rdg + dgt)
CL320 Specifications
CL340/CL345Leakage Clamp-on Testers
• ACA• ϕ 40• AC/40 mA to 400 A• RMS for CL345
Leakage current measurement
ACA
Item Range
40 mA/400 mA
400 A (0 to 350 A)
400 A (350 to 400 A)
2.5 + 10 (20 to 1 kHz)
2.5 + 10 (40 to 1 kHz)
5.0 (40 to 1 kHz)
1.0 + 5 (50/60 Hz)
1.0 + 5 (50/60 Hz)
2.0 (50/60 Hz)
Accuracy
WIDE (20 Hz) 50/60 Hz
Accuracy: (23°C ±5°C, Less than 85% RH), ±(% rdg + dgt)
CL340 Specifications
CL360Leakage Clamp-on Tester
• ACA• ϕ 68• AC/200 mA to 1000 A• DC/AC Output
Wide Range of Leakage current measurement
ACA
Item Range
20 mA/2 A/20 A
200 A
1000 A (0 to 500 A)
1000 A (501 to 1000 A)
1.0 + 2 (50/60 Hz)
3.0 + 2 (40 to 1 kHz)
1.5 + 2 (50/60 Hz)
3.5 + 2 (40 to 1 kHz)
1.5 + 2 (50/60 Hz)
3.5 + 2 (40 to 1 kHz)
5.0 (50/60 Hz)
10.0 (40 to 1 kHz)
1.5 + 2
2.0 + 2
2.0 + 2
5.5
Accuracy
WIDE (40 to 1 kHz) 50/60 Hz
Accuracy: (23°C ±5°C, Less than 85% RH), ±(% rdg + dgt)
CL360 Specifications
DCA
ACA
Item Range
400/2000 A
400 A/2000 A (150 to 1700 A)
2000 A (1701 to 2000 A)
1.5 + 2
1.5 + 3 (50/60 Hz)
3.0 + 4 (30 to 1 kHz)
3.5 + 3 (50/60 Hz)
Accuracy
Accuracy: (23°C ±5°C, Less than 75% RH), ±(% rdg + dgt)
CL255 Specifications
ACA
Item Range
40 mA/400 mA
400 A (0 to 300 A)
400 A (300 to 400 A)
2.5 + 10 (20 to 1 kHz)
2.5 + 10 (40 to 1 kHz)
5.0 (40 to 1 kHz)
1.0 + 5 (50/60 Hz)
1.0 + 5 (50/60 Hz)
2.0 (50/60 Hz)
Accuracy
WIDE (20 Hz) 50/60 Hz
Accuracy: (23°C ±5°C, Less than 85% RH), ±(% rdg + dgt)
CL345 Specifications
30031A/30032ALeakage Clamp-on Tester
• ACA• ϕ 40• AC/3 mA to 60 A
ACA
Item Range
0 to 30 mA
0 to 50 A
50 to 60 A
1.0 + 5 (50±1.0 Hz/60±1.0 Hz)
5.0 + 5 (50±1.0 Hz/60±1.0 Hz)
1.5 + 5 (50±1.0 Hz/60±1.0 Hz)
5.5 + 5 (50±1.0 Hz/60±1.0 Hz)
Accuracy
30031 A, 30032 A Filter OFF 30032 A Filter ON
Accuracy: (23°C ±5°C, Less than 80% RH), ±(% rdg + dgt)
30031A/30032A Specifications
CL420Clamp-on Process Meter
• DCmA• ϕ 6• DC/20 mA to 100 mA• DC Output
DC signals of 4 to 20 mA measurement
DCmA
Item Range
20 mA
100 mA
0.2 + 5
1.0 + 5
Accuracy
Accuracy: (23°C ±5°C, Less than 80% RH), ±(% rdg + dgt)
CL420 Specifications
Insu
latio
n Tes
ter
74
Insulation Tester
Selection Guide
Two choices:Choose an analog model if visual recognition is of utmost importance, or a digital model if precise numeric recognition is of utmost importance.
Type
A wide choice of voltage/resistance ratings, from 25 V/5 MΩ to 1000 V/2000 MΩSome models have two or three ranges; thus, you need not take more than one instrument to the site.
Ratings
Each series includes a model or models with a backlight for working in dark places. Multifunc-tional models are capable of AC voltage measurement also.
Functionality
Optional test probes and probe tips are available for a variety of test environments.
Accessories
Points on How to Choose an Insulation Tester
3 1/2-digit
LCD
Automatic discharge
Conductor resistancemeasurement
Comparator function
Memory function
P.75
125 V/200 MΩ250 V/200 MΩ500 V/2000 MΩ1000 V/2000 MΩ
Automatic discharge
Battery check
Automatic discharge
Battery check
Battery check
P.76
P.76
3213A
Dig
ital in
su
latio
n te
ste
rsA
nalo
g in
su
latio
n te
ste
rs
4
ranges
2 & 3
ranges
Single
range
Single
range
Analog
Analog
Analog
MY40
2406E
MY10
Type RatingSuffix Code
& Backlight
Series/
ModelDisplay Additional Function External View Page
AC VoltageMeasuring range
25 V/5 ΜΩ
50 V/10 ΜΩ
125 V/20 ΜΩ
125 V/20 ΜΩ
250 V/50 ΜΩ
125 V/20 ΜΩ
250 V/50 ΜΩ
500 V/100 ΜΩ
250 V/50 ΜΩ
500 V/100 ΜΩ
1000 V/2000 ΜΩ
250 V/500 ΜΩ
500 V/1000 ΜΩ
1000 V/2000 ΜΩ
125 V/20 ΜΩ
250 V/50 ΜΩ
500 V/100 ΜΩ
500 V/1000 ΜΩ
1000 V/2000 ΜΩ
100 V/20 ΜΩ
250 V/50 ΜΩ
500 V/100 ΜΩ
500 V/1000 MΩ
1000 V/2000 MΩ
31
41 (EL-illuminated)
32
42 (EL-illuminated)
33
43 (EL-illuminated)
34
44 (EL-illuminated)
35
45 (EL-illuminated)
01 (afterglow-illuminated)
02 (afterglow-illuminated)
03 (afterglow-illuminated)
04 (afterglow-illuminated)
05 (afterglow-illuminated)
41
42
43
44
45
01 (EL-illuminated) 0 to 600 V
0 to 300 V
0 to 300 V
0 to 600 V
0 to 600 V
0 to 600 V
0 to 250 V
0 to 300 V
0 to 500 V
0 to 500 V
0 to 500 V
0 to 150 V
0 to 250 V
0 to 300 V
0 to 300 V
0 to 300 V
P.76
Insu
latio
n Tes
ter
75
Insulation Tester
MY40Digital Insulation Tester
Features
• Multifunction Insulation resistance, AC voltage and conductor resistance measurement Insulation test mode: Comparator, memory, auto-hold and discharge functions All test modes: Live-line alarm (excluding AC voltage measurement), battery
check and automatic power-off• Easy-to-view, fluctuation-free display• Double-action safety mechanism
General Specifications
Dimensions: 125 (W) × 103 (H) × 53 (D) (mm)Weight: 420 g (main unit and batteries only)Batteries: Four AA (R6P) batteries
125 V/200 MΩ
250 V/200 MΩ
500 V/2000 MΩ
1000 V/2000 MΩ
MY40-01
.4000
4.000
40.00
200.0
.4000
4.000
40.00
200.0
4.000
40.00
400.0
2000
4.000
40.00
400.0
2000
.1 kΩ1 kΩ
10 kΩ100kΩ.1 kΩ1 kΩ
10 kΩ100 kΩ
1 kΩ10 kΩ
100 kΩ1 MΩ1 kΩ
10 kΩ100 kΩ
1 MΩ
0 to .0199 MΩ.0200 to 10.00 MΩ10.01 to 200.0 MΩ
0 to .0499 MΩ.0500 to 20.00 MΩ20.01 to 200.0 MΩ
0 to 0.999 MΩ1.000 to 500 MΩ501 to 2000 MΩ
0 to 1.999 MΩ2.000 to 1000 MΩ1001 to 2000 MΩ
± (5% of rdg+6 dgt)
± (2% of rdg+6 dgt)
± 5% of rdg
± (5% of rdg+6 dgt)
± (2% of rdg+6 dgt)
± 5% of rdg
± (5% of rdg+6 dgt)
± (2% of rdg+6 dgt)
± 5% of rdg
± (5% of rdg+6 dgt)
± (2% of rdg+6 dgt)
± 5% of rdg
0.125 MΩ
0.25 MΩ
0.5 MΩ
2 MΩ
1 mA
1 mA
1 mA
0.5 mA
5 MΩ
5 MΩ
50 MΩ
50 MΩ
Model RatingRangeOption
Resolution Measuring Range Tolerance Lower Limit ofmeasured Ω
RatedCurrent
Central ScaleValue
AC voltage measurement (45-400 Hz)
Conductor resistance measurement
Model Range Resolution Accuracy Input Impedance
MY40-01 1 V ±(2% of rdg + 6 dgt) Approx. 2 MΩ
Model Range Resolution Accuracy Open-circuit Voltage
Buzzer soundresistance: <40 Ω.
Standard test conditions
Ambient temperature/humidity ranges: 23 ±5°C/45-75% RH
Tolerances under the above-mentioned conditions:
Deviation from zero scale value: 6 digits maximum
Indication of ∞mark on bar graph: Approx. 4000 MΩ min. (500 V/1000 V)
Approx. 400 MΩ min. (125 V/250 V)
Open circuit voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit Current: 2 mA max.
* First effective measuring range; ** The minimum value at which the rated voltage can be maintained
*
*
*
*
600 V
MY40-01 400 Ω 0.1 Ω ±(2% of rdg + 8 dgt)
Testing Performance Specifications
125 V/200 MΩ250 V/200 ΜΩ500 V/2000 ΜΩ1000 V/2000 ΜΩ
3213A
Dig
ital i
nsul
atio
n
test
ers
Ana
log
insu
latio
n te
ster
s
4ranges
2 & 3ranges
Singlerange
Singlerange
Type RatingSuffix Code(BackLight)
Series/Models
Series/Models References and notes
Existing products Discontinued products for replacing
25 V/5 ΜΩ50 V/10 ΜΩ125 V/20 ΜΩ125 V/20 ΜΩ250 V/50 ΜΩ125 V/20 ΜΩ250 V/50 ΜΩ500 V/100 ΜΩ250 V/50 ΜΩ500 V/100 ΜΩ1000 V/2000 ΜΩ250 V/500 ΜΩ500 V/1000 ΜΩ1000 V/2000 ΜΩ125 V/20 ΜΩ250 V/50 ΜΩ500 V/100 ΜΩ500 V/1000 ΜΩ1000 V/2000 ΜΩ100 V/20 ΜΩ250 V/50 ΜΩ500 V/100 ΜΩ500 V/1000 ΜΩ1000 V/2000 ΜΩ
31
41 (EL-illuminated)
32
42 (EL-illuminated)
33
43 (EL-illuminated)
34
44 (EL-illuminated)
35
45 (EL-illuminated)
01
02
03
04
05
41
42
43
44
45
01 (EL-illuminated)
240651 to 55*1
240661 to 65*1
3213D31 to D35*2
240631
–
240622
240626
240623/25
240621
321346
240301
240302
–
240305
321321
321322
321323
321324
321325
MY40
2406E
MY10
*1 2406D series is single or 2 range.
*2 3213D series is single range.
Digital model with 4 voltage/resistance ratings
Simple selection for replacing discontinued products
Insu
latio
n Tes
ter
76
Insulation Tester
2406E SeriesAnalog Insulation Testers
Analog models with two and three ratings
Features
• AC voltage measurement• Automatic discharge• Sky blue EL backlight• Increased safety (covered battery charger)
General Specifications
Dimensions (main unit): Approx. 120 (W) × 110 (H) × 60 (D) (mm)Weight: Approx. 500 g (including batteries)Batteries: Six AA (R6P) batteries
Testing Performance Specifications
MY10 SeriesAnalog Insulation Testers
Analog models with single rating
Features
• AC voltage measurement• Automatic discharge• A wide choice of accessories –Designed for shared use with the MY40
General Specifications
Dimensions: Approx. 125 (W) × 103 (H) × 53 (D) (mm)Weight: Approx. 400 g (main unit and batteries only)Batteries: Four AA (R6P) batteries
Testing Performance Specifications
Lower Limit ofMeasured Ω*
Model Rating Effective Measuring RangeCentral Scale
Value
AC VoltageMeasuring Range
Rated Current
125 V/20 MΩ250 V/50 MΩ
500 V/100 MΩ500 V/1000 MΩ
1000 V/2000 MΩ
0.5 MΩ1 MΩ2 MΩ
20 MΩ50 MΩ
0.01 to 20 MΩ0.01 to 50 MΩ
0.05 to 100 MΩ0.5 to 1000 MΩ
1 to 2000 MΩ
0 to 250 V
0 to 300 V
0 to 500 V
0 to 500 V
0 to 500 V
0.125 MΩ0.25 MΩ0.5 MΩ
1 MΩ2 MΩ
1 to 1.2 mA
1 to 1.2 mA
1 to 1.2 mA
0.5 to 0.6 mA
0.5 to 0.6 mA
MY10-01
MY10-02
MY10-03
MY10-04
MY10-05
* The minimum value at which the rated voltage can be maintained
3213A SeriesAnalog Insulation Testers
Analog models with single rating
Features
• AC voltage measurement and check live lines such as motive power lines• One-touch operation Press-and-lock switch for continuous measurement• A wide choice of accessories to meet various testing requirements• Vibration- and shock-resistant hand-held compact testers
General Specifications
Dimensions: Approx. 110 (W) × 180 (H) × 60 (D) (mm)Weight: Approx. 700 g including batteries, or approx. 1.2 kg including hard case,
handle, test leads and batteriesBatteries: Eight AA (R6P) batteries
Testing Performance Specifications
Lower Limit ofmeasured Ω Model Rating
EffectiveMeasuring Range
CentralScale Value
AC VoltageMeasuring Range
Rated Current
* The minimum value at which the rated voltage can be maintained; ** 0.55 mA in the case of the first effective measuring range
100 V/20 MΩ250 V/50 MΩ
500 V/100 MΩ500 V/1000 MΩ
1000 V/2000 MΩ
0.5M Ω1M Ω2M Ω
20M Ω50M Ω
0.02 to 20 MΩ0.05 to 50 MΩ0.1 to 100 MΩ1 to 1000 MΩ2 to 2000 MΩ
0 to 150 V
0 to 250 V
0 to 300 V
0 to 300 V
0 to 300 V
0.1 MΩ0.25 MΩ0.5 MΩ0.5 MΩ
1 MΩ
1 mA
1 mA
1 mA
1 mA**
1 mA**
321341
321342
321343
321344
321345
240632240642
240631
240641
240633
240643
240635
240645
240634
240644
25 V/5 MΩ50 V/10 MΩ
125 V/20 MΩ125 V/20 MΩ250 V/50 MΩ125 V/20 MΩ250 V/50 MΩ
500 V/100 MΩ250 V/50 MΩ
500 V/100 MΩ1000 V/2000 MΩ
250 V/500 MΩ500 V/1000 MΩ
1000 V/2000 MΩ
0.001 to 5 MΩ0.005 to 10 MΩ0.01 to 20 MΩ0.01 to 20 MΩ0.01 to 50 MΩ0.01 to 20 MΩ0.01 to 50 MΩ
0.05 to 100 MΩ0.01 to 50 MΩ
0.05 to 100 MΩ1 to 2000 MΩ
0.1 to 500 MΩ0.5 to 1000 MΩ
1 to 2000 MΩ
0.1 MΩ0.2 MΩ0.5 MΩ0.5 MΩ
1 MΩ0.5 MΩ
1 MΩ2 MΩ1 MΩ2 MΩ
50 MΩ10 MΩ20 MΩ50 MΩ
0.025 MΩ0.05 MΩ
0.125 MΩ0.125 MΩ
0.25 MΩ0.125 MΩ
0.25 MΩ0.5 MΩ
0.25 MΩ0.5 MΩ
1 MΩ0.25 MΩ0.5 MΩ
1 MΩ* The minimum value at which the rated voltage can be maintained;** 0.55 mA in the case of the first effective measuring range
0 to 300 V
0 to 300 V
0 to 600 V
0 to 600 V
0 to 600 V
Lower limit ofmeasured ΩModel Rating
EffectiveMeasuring range
CentralScale Value
AC VoltageMeasuring range
Rated Current
1 mA1 mA1 mA1 mA1 mA1 mA1 mA1 mA1 mA1 mA1 mA**1 mA**1 mA**1 mA**
Non-Back-LightEL-Back-Light
Insu
latio
n Tes
ter
77
Insulation Tester
Quick-reference Table of Accessories
58
9
ϕ 4
1 2
108
8
ϕ 3
1 3 2
360 ±5
1 3 2
32.5
68
1000 ±10
99011
B9600GN
B9600NZ
B9600NX
No. Description
Testing shank
Fastening nut
PVC-clad
1
2
3
Metal shank with ϕ 6 screw
ABS resin
Remarksϕ 3
105
Note that the color of the plastic part of a probe tip may not always match that of the probe, depending on the combination.
*1 Regarding external dimensions of cases, Pls refer to each product specification.
*2 For using with MYSeries, 98052 is necessary.
98007
Line probe
Earth probe
125
32.5 1000 ±10
160
ϕ 26
Probes Unit: mm
55 16
11 16 1000
3218 03B9303XE
Spare Probe Tips Others Unit: mmUnit: mm
98050
Series/Model 3213A 2406E MY10 MY40
For breaker pins
General-purpose
Extended
Sharp-pointed
Line probe
Earth probe
Measuring Lead unit (Paired earth/line terminals)
Replaceable type Line Probe
Bag for housing spare probe tips
Accessory-housing case
Carrying case
Protection cover
Shoulder strap
Handle
Lead for guard terminals
–
–
–
98050
–
B9600NV
B9646CA
B9600HA
w/accessory-
housing case
–
–
B9303XE
–
98007
Earth and Line probes
–
–
–
B9108XA
–
–
–
–
–
93015
Store main unit
/accessories
–
–
–
–
93015
Store main unit
/accessories
–
–
Note: Includes an accessory-housing case.
B9075MU(hard case)
B9075MV(soft case)
321803
B9600GN
B9600NX
B9600NZ
99011
B9600GN *2
B9600NX *2
B9600NZ *2
98001
98002
–
B9108XA
93013
99005
Spare
probe tip
Case
*1
Probe
Others
980011200mm
980021200mm
(176)
(78)
1000±10
85
35.4
20
1000±10
Eart
h Tes
ter,
Oth
er P
rodu
cts
78
Earth Tester/Leakage Current Tester/Illuminance Meter
Earth Tester Capable to Measure by 3 Pole or 2 Pole Method
322610Leakage Current Tester
• Three input resistance ranges – 1, 1.5 and 2 kΩ • Four functions – AC current, DC current, DC + AC current and AC voltage measurements• ±2.5% full scale accuracy• 100 μA full scale value• Shockproof indicator using taut band movement• Built-in overload protection circuit• Handy and easy to carry• Shielded case, resistant to high-frequency fields
322610 Specifications
Range: DC current ... 0.1, 1, 10 mA, AC current .... 0.1, 1, 10 mA, (DC + AC) current ... 0.1, 1, 10 mA, AC Voltage ... 150, 300 V (50 and 60 Hz) Accuracy: ±2.5% of full scale value on current and voltage rangesInput Impedance: Current range; 1 kΩ, 1.5 kΩ, and 2 kΩ Voltage range; More than 100 kΩFrequency Range: 20 Hz to 5 kHzPower Source: Two 9 V dry cells, Continuous Operating Time; Approx. 290 hoursOverload Protection: Up to 30 mA AC for one minute will not damage instrument on current
rangesDimensions: Approx. 190 × 124 × 90 mm not including handleWeight: Approx. 1.0 kg
Handy Universal Tester for Checking Electrical Appliances
510 SeriesDigital Lux Meter
• Wide range, High Accuracy• Average illuminance computation function• Timer hold• USB communication
510 Series Specifications
Photoelectric Element: Silicon PhotodiodeMeasuring Range: 0.0 to 99.9/999/9,990/99,900/999,000lXResponse Time: 5 sec. (Auto Range) 2 sec. (Manual Range)Accuracy: ±4% rdg. ±1 dgt. (51011)
±2% rdg. ±1 dgt. (51012, 51021)General Specifications • External dimensions (main unit): Approx. 67 (W) × 177 (H) × 38 (D) (mm) • Weight: Approx. 260 g • Batteries: AA (LR6) × 2
Excellent Performance, Multiple Functions
EY200Digital Earth Tester
• Capable to measure by 3-pole or 2-pole measuring• Easy to measure with one touch button and dedicated test lead• Small and lightweight• Dust and drip proof (designed to IEC60529 IP54)
EY200 Specifications
Display LCD Digital Display: 1999-count digital readingMeasuring Range Earth Resistance: 2000 Ω LSD: 0.01 to 1 Ω Earth Voltage: 200 VAccuracy Earth Resistance: 20 Ω range: ±2%rdg±0.1 Ω 200 Ω range: ±2%rdg±3 dgt 2000 Ω range: ±2%rdg±3 dgt Earth Voltage: ±1%rdg±4 dgtMeasuring Frequency Approx. 820 HzMeasuring Current Approx. 3 mA (at 20 Ω range)Battery Life Approx. 4.5 hours (at 5 second measuring 3300 times)Operating Temp. 0 to 40°C, 85%Rh or lessand Humidity 0 to 40°C, 85%Rh or lessDimensions Approx. 105 × 158 × 70 mmWeight Approx. 550 g
Ther
mom
eter
79
Thermometer
TX10 SeriesDigital Thermometers
TX1001: 1-channel Single-function with data hold
functionTX1002: 1-channel Multifunction with data hold,
internal memory, user-calibration and relative display function
TX1003: 2-channel Multifunction with data hold,
internal memory, user-calibration and relative display function
TX10 Series Specifications
• Thermocouple measurement ranges Type K: -200 to 1372 deg.C Type J: -200 to 1000 deg.C Type E: -200 to 700 deg.C Type T: -200 to 400 deg.C • Resolution -200.0 to 199.9 deg.C: 0.1 deg.C, 200
deg.C: 1 deg.C (TX1001) -200.0 to 199.9 deg.C: 0.1 deg.C or 1
deg.C (when resolution is set at 1 deg.C), 200 deg.C: 1 deg.C (TX1002, 03) • Accuracy -200.0 to -100.1 deg.C: +/-(0.1% of rdg +
1.0 deg.C); -100.0 to 199.9 deg.C: +/-(0.1% of rdg +
0.7 deg.C); 200 deg.C and when resolution is set at
1 deg.C:+/-(0.2% of rdg + 1 deg.deg.C) General Specifications • External dimensions: 56 (W) × 151 (H) × 33 (D) mm • Weight: Approx. 180 g • Power: Two AA size (LR6) dry batteries
Simplified Thermometer with easy operation
TM20Thermo-collectors
• Effective for HACCP program implementation.• Collect up to 5000 data items with time-stamp, tag name and inspector name.• Save 2 weeks continuous data logging with 1 minute interval, (up to 20000 data items,
measuring interval is 1sec. to 24 houres.) Information on when, by whom and what is measured is saved along with the data.
Model
Temperature Probe (for type K)
90020
90021
90022
90023
90024
90030
90031
90032
90033
245907
rounded end
rounded end
rounded end
needle
needle
Surface straight
Surface angled
Surface straight
Surface angled
Bead TC
-50 to 600°C
-50 to 600°C
-50 to 600°C
-50 to 500°C
-50 to 500°C
-20 to 250°C
-20 to 250°C
-20 to 500°C
-20 to 500°C
-40 to 260°C
0.4% or ±1.5°C
0.4% or ±1.5°C
0.4% or ±1.5°C
0.4% or ±1.5°C
0.4% or ±1.5°C
0.75% or ±2.5°C
0.75% or ±2.5°C
0.75% or ±2.5°C
0.75% or ±2.5°C
0.75% or ±2.5°C
1.4
0.4
1.4
0.4
1
2
2
2
2
(90% response)
3.2 / 200
1.6 / 150
3.2 / 500
1.6 / 100
2.1 / 100
15 (temp. sensing portion)
15 (temp. sensing portion)
15 (temp. sensing portion)
15 (temp. sensing portion)
1200 (included cord)
Probe type Measuring range AccuracyResponse
time (second)Sensor
Dimenter / Length (m/m)
NOTE: 90030 is using polyimide to insulate from objects to be measured.Manufacturers of polyimide are announcing not to apply polyimide directly for food, internal and body fluid.
Probes for TM20/TX10
Dimensions
Approx. 151(H) × 56(W) × 33(D) mm
(excluding protrusions)
Weight: Approx. 180 g
(including batteries)
TM20 Thermo-collector
Thermocouple model
(54011)
Thermocouple Type K : -200°C to 1372°C
Type J : -200°C to 1000°C
Type E : -200°C to 700°C
Type T : -200°C to 400°C
Voltage input ±100 mV, ±1 V
2
Collector mode:
0.5 seconds or longer when 1 channel is used.
Logging mode:
1 second to 24 hours when 1 channel is used.
Thermocouple -200.0 to 100.1°C
: ±(0.1% of rdg + 0.7°C)
-100.0°C or above
: ±(0.1% of rdg + 1.0°C)
Voltage input ±(0.1% of rdg + 0.2% of range)
Product name
(Model)
Number of measuring
channels
Data capacity
Measuring range
(only the main unit)
Accuracy
(only the main unit)
Supplied accessories
Measuring
interval
External
dimensions
5000 data items when used in collector mode only,
20000 data items when used in logging mode only.
Software, two AA-size alkaline dry batteries (LR6), a waterproof cover, and an instruction manual
TM20 Specifications
Model
91011
Product name
RS-232C cable for PC connection (9-pin)
Optional Accessories for TM20
Handy temperature data logger
90033Material:SUS316
90021Material:SUS316
90022Material:SUS316
90023Material:SUS316
90024Material:SUS316
245907
90030Material:SUS316
90031
Material:SUS316
90020Material:SUS316
heat-resistantPVC
1200110200
22 143.2
13
heat-resistantPVC
1200110150 13
22 141.6
heat-resistantPVC
1200110500 13
22 143.2
heat-resistantPVC
1200110100 13
22 141.6
45°
siliconrubber
1200110100 13
22 142.1
45°
1200
siliconrubber
siliconrubber
1200110
1200110
56 12
55.5 12
26
14
25.5
13.5
22
6
22
6
1414
1515
siliconrubber
siliconrubber
1200110100 12
1200110100 12
4.8
4.8
15
15
2222
1414
4645
.5
14
2913
.5 28.5
90032Material:SUS316
Pre
cisi
onM
easu
ring
Inst
rum
ents
80
Precision Measuring Instruments
2769Portable Double Bridge
Model 2769 is a compact, portable Kelvin double bridge designed for measuring low resistance from 0.1 mΩ to 110 Ω with four multiplication plugs and one measuring dial. It has built-in standard resistors, bridge power source and high-sensitivity taut-band suspension system electronic DC galvanometer.
2769 Specifications
Measuring Range: 0.1 mΩ* to 110 Ω.Measuring Dial: 1.00 to 11.00 Ω at × 1.Multipliers: × 0.0001*, × 0.001, × 0.01, × 0.1, ×
1, × 10 (plug-in system).Min. Division: 0.005 mΩ at × 0.0001*,
0.05 mΩ at × 0.001, 0.5 mΩ at × 0.01, 5 mΩ at × 0.1, 50 mΩ at × 1, 0.5 Ω at × 10.
Accuracy: ± (0.05 Ω × multiplier + 0.01 mΩ) Current Rating: 10 A at × 0.0001*
(0.01 Ω), 3 A at × 0.001 (0.1 Ω), 1 A at × 0.01 (1 Ω). 0.3 A at × 0.1 (10 Ω), 0.1 A at × 1 (100 Ω), 0.01 A at × 10 (1,000 Ω).
Galvanometer: Built-in electronic DC galva-nometer, voltage sensitivity ... approx. 20 μV/div.
sensitivity changeover; G0 ... (Input resistance: approx. 11 kΩ). G1 ... approx. 1/11 of G0 sensitivity. G2 ... approx. 1/110 of G0 sensitivity.Operating Temperature Range: 5 to 35°CHumidity Range: Less than 85% Bridge Power Source: Tow 1.5 V batteries,
External power source is also usable.*Note: Standard Resistor (Model 2771) is re-
quired for measurement on 0.1 to 1.1 mΩ range at 0.0001 multiplier.
0.1 mΩ to 110 Ω with four plugs and one measuring dial
2755Portable Wheatstone Bridge
Model 2755 measures resistances from 1 Ω to 10 MΩ by operation of dials and switches. Batteries and a galvanometer are self-contained. The front control panel is provided with power and galvanometer circuit selectors, one ratio arm dial, and four measuring arm dials.
2755 Specifications
Measuring Range: 1,000 Ω to 10.00 Ω.Measuring Arms: 1 Ω × 10 + 10 Ω × 10 + 100
Ω × 10 + 1,000 Ω × 10 (min. one step: 1 Ω).Ratio Arms (Multiplier): × 0.001, × 0.01, ×
0.1, × 1, × 10, × 100, × 1,000 (M10, M100, M1000 ... Murray & Varley loop testing).
Accuracy: ±0.1% of reading on 100 Ω to
100 kΩ range, ±0.3% of reading on 10 Ω
to 1 MΩ range, ±0.6% of reading on 1Ω to
10 MΩ range.
Temperature Coefficient of Resistance Ele-ments: ±5 × 10-5/°C at ambient temperature of 5 to 35°C, ±2 × 10-5/°C at ambient temperature 20 to 35°C.
Galvanometer: Sensitivity ... 0.9 μA/div., inter-nal resistance ... Approx. 150 Ω, external critical damping resistance ... Approx. 800 Ω, period ... within 1.5 seconds.
Power Source: Three 1.5 V batteries (built-in).Operating Temperature Range: 5 to 35°C.Humidity Range: 85% max., relative humidity.Outer Case: ABS resin.Accessory supplied at no extra cost: Carrying case.
1 Ω to 10 MΩ by operation of dials and switches
278610/278620Decade Resistance Boxes
Models 278610 and 278620 six-dial decade resistance boxes allow quick and easy setting of a wide range of resistance. These resistance boxes are used in combination with voltage or current standards to adjust voltage or current, as dummy load resistances or as an arm of AC bridges.
278610/278620 Specifications
Available Models:
Model Number Resistance Range
278610 0.1 to 111,111 Ω (six decade dials)
278620 1 to 1,111,110 Ω (six decade dials)
Residual Resistance: Less than 23 mΩ.Power Rating: 0.3 W/step, within 3 W for
overall instrument.Maximum Allowable Input: 0.5 W/step, 5 W
for overall instrument.Maximum Circuit Voltage: 250 V.Operating Temperature Range: 0 to 40°C Storage Temperature Range: -10 to 50°C Humidity Range: 25 to 85%, relative humidity.Insulation Resistance: More than 500 MΩ at
500 V DC.Dielectric Strength: 1,500 V AC for one minute.
Quick and easy setting
279301/279303Decade Resistance Boxes
279301• High accuracy and stability• High reproducibility• 1 mΩ resolution
279303• Up to 100 MΩ in 100 Ω step• Low voltage coefficient• Shock- and vibration-proof construction
279301 Specifications
Resistance Range: 0.100 to 1,111.210 Ω (Mini-mum resistance is 0.100 Ω).
Dial Composition: 0.001 × 10 + 0.01 Ω × 10 + 0.1 Ω × 11 + 1 Ω × 10 + 10 Ω × 10 + 100 Ω × 10
Resolution: 0.001 ΩAccuracy: ± (0.01% + 2 mΩ) at temperature
23 ± 2°C, humidity 45 to 75%, and 0.1 W power application
High-accuracy, DC variable resistor with 6 dials
2792A SeriesStandard Resistors
• Traced to the national standard for high accuracy; test (calibrated) accuracy of ±5 ppm
• Resistance temperature coefficient• A variety of models Eight models with nominal resistance
values ranging between 0.001 Ω and 10 kΩ• Precision temperature control equipment,
such as an oil bath, not needed for calibration due to marked improvement in resistance temperature coefficient
• Included document: Test certificate
2792A series Specifications
Metal foil resistors
Operating temperature and humidity ranges: 0 to 50°C / 20 to 80% RHMaximum allowable power: 3 WTest (calibrated) accuracy: ±5 ppmPower characteristics: ±100 ppm/WInsulation resistance: More than 1000 MΩ at 500 V DCWithstand voltage: 1.5 kV for one minute be-
tween measurement terminal and casingTerminal construction: 4 terminalsExternal dimensions: Approximately ϕ 104 ×
150 mm (current terminal width: approxi-mately 174 mm)
Weight: Approximately 1.2 kgAccessories: User'S Manual, One Test Cer-
tificate
279303 Specifications
Resistance Range: 0 to 111. 1110 MΩ.Dial Composition: 100 Ω × 10 + 1 kΩ × 10 +
10 kΩ × 10 + 100 kΩ × 10 + 1 MΩ × 10 + 10 MΩ × 10.
Accuracy: 100 Ω, 1 kΩ, 10 kΩ and 100 kΩ steps ... ± (0.05% + 0.05 Ω)
1 MΩ and 10 MΩ steps ... ±0.2% (At temperature 23 ± 2°C, humidity below
75%, including residual resistance of ap-prox. 0.05 Ω).
Model Nominal value Accuracy 23°C±2°C
2792A01 0.001 Ω ±100 ppm
2792A02 0.01 Ω ±75 ppm
2792A03 0.1 Ω ±50 ppm
2792A04 1 Ω ±30 ppm
2792A05 10 Ω ±30 ppm
2792A06 100 Ω ±30 ppm
2792A07 1 kΩ ±30 ppm
2792A08 10 kΩ ±30 ppm
Met
ers
Pro
duct
s
81
Meters Products
Portable Instruments
2011 to 2053Portable Instruments
• Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
• Stable performance for long term use.• Products have been widely used over many years as an industry standard at various
customers such as industries, power plants, research laboratories and schools, etc.
Line-up
DC Ammeters and Voltmeters 2011, 2012AC Ammeters and Voltmeters 2013, 2014Audio-frequency AC Voltmeters 2017Frequency Meters 2038Power Factor Meters 2039Wattmeters 2041, 2042Miniature DC Ammeters and Voltmeters 2051Miniature AC Ammeters and Voltmeters 2052, 2053
201314 205206
Recorders and Data Loggers
82
Model GP10 GP20-1 GP20-2 GM10-1 GM10-2
Mounting Desktop Desktop, DIN rail, vertical panel mount (screws)
Display (TFT color LCD) 5.7" (640 × 480 dots)
12.1" (800 × 600 dots)
Touch screen 4-wire resistive touch screen, 2-point touch detection
No. of connectable modules
3 10 10 (Up to 8 when GX90XA-10-T1 is mounted)
Max. (with expansion units) 10 10 45 10 42
No. of connectable expansion (sub) units
6 6 6 6 6
Max. no. of I/O channels 100 100 500 100 500
No. of connectable WT communication units (/E2*)
8 16 16 16 16
No. of communication channels (/MC*)
50 300 500 300 500
No. of channels allocatable to WT (/E2*)
50 300 300 300 300
No. of mathematical channels (MT*)
50 100 200 100 200
No. of recording channels 500 500 1000 500 1000
Internal memory (flash) 500 MB 500 MB 1.2 GB 500 MB 1.2 GB
Communication interface Ethernet, RS-232 (/C2*), RS-422/485 (/C3*), USB host (/UH*)
Ethernet, USB, RS-422/485 (/C3*), Bluetooth (/C8*)
Rated supply voltage
AC model 100 to 240 VAC 100 to 240 VAC
DC model 12 VDC 12 to 28 VDC
Dimensions (W × H × D) with modules mounted
144 × 168 × 248 (mm)
288 × 318 × 248 (mm) Max. 638 × 137.7 × 146 (mm)
Ambient temperature 0 to 50°C -20 to 60°C (-20 to 50°C for some configurations)
Measurement interval: 100/200/500 ms, 1/2/5 s
(Some intervals are not available depending on system configurations and modules.)
External storage media: 1 to 32 GB SD/SDHC memory card (a 1 GB card is included)
Format: FAT32 or FAT16
Data format: Binary or text
Ethernet: 10Base-T/100Base-TX (E-mail, FTP, Web, SNTP, etc.)
WT communication (/E2*): Supported models: WT1800, WT500, WT300
Supported communication: Ethernet
Communication interval: 500 ms, 1/2/5/10/15/20/30 s
USB host for GP (/UH*): Complies with USB 2.0
(USB memory; keyboard or mouse complying with HID Class Ver. 1.1)
USB communication for GM: Complies with USB 2.0 (recognized as a serial port by a PC)
Bluetooth for GM (/C8*): Bluetooth® Ver 2.1+EDR compliant, SPP (serial port profile),
Class 2 (communication range: approx. 10 m depending on the usage environment)*: Option code
Expansion (sub) unit specifications GX60 GM configuration
Construction Desktop, vertical panel mount (screws) Desktop, DIN rail, vertical panel mount (screws)
No. of connectable modules 6 6
Rated supply voltage
AC model 100 to 240 VAC 100 to 240 VAC
DC model 12 to 28 VDC
Dimensions (W × H × D) with modules mounted
412.5 × 164.7 × 147 (mm) Max. 438 × 137.7 × 146 (mm)
Ambient temperature 0 to 50°C -20 to 60°C (-20 to 50°C for some configurations)
Smart user interface for intuitive operation (GP series)
Review historical data easily Display digital values at any location
DragPast
Flick
Present
Zoom in/out horizontally and vertically
Pinch apart/Pinch
together
Monitoring and setting on a tablet (GM10)
Supports Bluetooth (option code/C8). There is no need to bring a PC to the
site; you can use a tablet for setting and monitoring.
Multi-unit configuration by connecting expansion units
Supports measurements at up to 450 ch (GP20) and 420 ch (GM10)
Up to 6 expansion (sub) unitsMain unit
LAN cable (CAT5 or later)
( The maximum distance
between units is 100 m.)
Acquire data from power measuring instruments
The GP recorder and the GM system can acquire data from power measuring
instruments (WT series power analyzers) without loss of fidelity and record
and display with their own data (option codes /E2 and /MC).
Ethernet
Power
Temperature
Model Suffix code Name Specification/Application Shortest cycle
GX90XA -10-U2N-4N Analog input module 10 ch, universal, SSR scanner type (RTD b-terminal common) DCV: ±20/60/200 mV, 1/2/6/20/50 V, etc.TC: R/S/B/K/E/J/T/N, etc.RTD: Pt100/JPt100, etc.DI: Voltage/contactCurrent (mA): 0 to 20/4 to 20 mA
100 ms
-10-L1N-4N 10 ch, low withstand voltage, DCV/TC/DI, SSR scanner type (isolated between channels) 500 ms
-10-T1N-4N 10 ch, DCV/TC/DI, electromagnetic relay scanner type (isolated between channels) 1 s
-10-C1N-4N 10 ch, current (mA), SSR scanner type (isolated between channels) 100 ms
GX90YA -04-C1N-4N Analog output module 4 ch, current (mA), (isolated between channels) Current (mA): 0 to 20/4 to 20 mA 100 ms
GX90XD -16-11N-4N Digital input module 16 ch (shared common) Input: Open collector or non-voltage contact Application: Remote control or operation recording/pulse (125 Hz when filter is ON)Output: Form C relay (SPDT) Application: Alarm output
100 ms
GX90YD -06-11N-3N Digital output module 6 ch 100 ms
GX90WD -0806-01N-3N Digital I/O module Input 8 ch (shared common), output 6 ch 100 ms
GX90XP -10-11N-4N Pulse input module 10 ch (shared common)DC Voltage, Open collector or non-voltage contact Application: Pulse (up to 20 kHz)
100 ms
GX90EX -02-TP1N-N I/O expansion module Each of GP main body, GM main unit, and expansion (sub) unit can mount one GX90EX. (One GX90EX is provided with a GX60.)
The “-4” in the suffix code represents the terminal form (-3: M3 screw terminal, -C: Clamp terminal)
Up to 10 modules of GX90YD and GX90WD can be mounted in a system. Each of the GP main body, GM main unit, and expansion (sub) unit can mount one GX90WD.
The /MT option (MATH) is required for GX/GP/GM main unit to perform pulse measurement/integration on GX90XD/GX90WD, or pulse integration on GX90XP.
For details, please contact Yokogawa Electric Corporation: Phone: (81)-422-52-7179 / E-mail: [email protected]
SMARTDAC+ Paperless Recorder GP Series, Data Acquisition System GM
GP10 GP20 GM
Specifications
I/O Modules and GX90EX (I/O expansion module)
A Next-generation Data Acquisition and Control System with Excellent Operability and Expandability
Catalog: Bulletin 04L51B01-01EN for GP series/Bulletin 04L55B01-01EN for GM
Recorders and Data Loggers
83
For details, please contact Yokogawa Electric Corporation: Phone: (81)-422-52-7179 / E-mail: [email protected] http://www.smartdacplus.com/
SMARTDAC+ GA10 Data Logging Software
Models, Suffix Codes, and Configurations Please contact us for the prices.
Model Suffix Code Description
GM10 Data Acquisition Module for SMARTDAC+ GM
Type -1 Standard (Max. measurement channels: 100)
-2 Large memory (Max. measurement channels: 500)
Area E General (temp. unit: Cel, degF)
— 0 Always 0
Optional Features /AH Aerospace heat treatment
/AS Advanced security function (Part 11)
/BT Multi-batch function
/C3 RS-422/485
/C8 Bluetooth
/E1 EtherNet/IP communication (PLC communication protocol)
/E2 WT communication /MC option must be specified.
/E3 OPC-UA server
/E4 SLMP communication (Mitsubishi PLC)
/LG Log scale
/MC Communication channel function
/MT Mathematical function (with report function)
Model Suffix Code Description
GM90PS Power Supply Module for SMARTDAC+ GM
Type -1 Always -1
Region N General
Supply Voltage 1 100 to 240 VAC
2 12 to 28 VDC Power Supply Connection: W only
Power Supply Connection D Power inlet with UL/CSA cable
F Power inlet with VDE cable
H Power inlet with GB cable
N Power inlet with NBR cable
Q Power inlet with BS cable
R Power inlet with AS cable
W Screw terminal (without power cable)
— 0 Always 0
Model Suffix Code Description
GM90MB -01N0 Module Base for SMARTDAC+ GM
Model Suffix Code Description
GX60 I/O base unit
Type -EX I/O expansion
Area N General
Power Supply 1 100 VAC, 240 VAC
Power Cord D Power cord UL/CSA standard
F Power cord VDE standard
R Power cord AS standard
Q Power cord BS standard
H Power cord GB standard
N Power cord NBR standard
W Screw terminal (power cord not included)
Model Suffix Code Description
GP10 Paperless recorder (portable type with a small display)
GP20 Paperless recorder (portable type with a large display)
Type -1 Standard (max. measurement channels: 100)
-2 Large memory (max. measurement channels: 500) (GP20 only)
Display Language E English, degF, DST (summer/winter time)
Power Supply 1 100 VAC, 240 VAC Power cord W cannot be specified
2 12 VDC (GP10 only) With power cord W only
Power Cord D Power cord UL/CSA standard
F Power cord VDE standard
R Power cord AS standard
Q Power cord BS standard
H Power cord GB standard
N Power cord NBR standard
W Screw terminal, power cord not included
Optional Features /AH Aerospace heat treatment
/AS Advanced security function (Part 11)
/BT Multi-batch function
/C2 RS-232Cannot be specified together.
/C3 RS-422/485
/CG Custom display
/D5 VGA output (only for GP20)
/E1 EtherNet/IP communication (PLC communication protocol)
/E2 WT communication /MC option must be specified.
/E3 OPC-UA server
/E4 SLMP communication (Mitsubishi PLC)
/FL Fail output (1 point)
/LG Log scale
/MC Communication channel function
/MT Mathematical function (with report function)
/UH USB interface (2 host ports)
Recorders can be shipped with specified I/O modules mounted (optional).
Monitors and records data from power meters, recorders, and data loggers
GA10 is a PC based software package that acquires data from
multiple devices – such as power meters (WT series), recorders,
and data loggers. Connected PCs can monitor real time and
historical data, which can be stored on a PC hard drive.
Max. connectable devices: 100
Max connectable clients: Unlimited (Connection with up to 32 units has been
verified.)
Max. recording tags (channels): Tags: 2000 ch
Mathematical tags (option code/MT): 200 ch
Scan interval: 100 ms at shortest (depending on the scan interval of
each instrument when using instrument time)
Multi-logging
Multi-logging function enables
acquisition of multiple data at
different timing. Data for each
testing instrument can be
processed separately.
Reporting/printing
Reports can be printed
automatically. The layout
can be customized. The
insertion of waveforms and
images, and the creation
of spreadsheets in PDF or
Excel format are supported (suffix code /RP).
Catalog: Bulletin 04L65B01-01EN
Expansion (sub) unit configuration
GP main body configuration GM main unit configuration
Recording Test equipment AStart Stop No.1
Stopped Test equipment BStart Stop No.2
Standby Test equipment CStart Stop No.3
Current time
Data logging softwareModel Suffix Code Description
GA10 Data Logging Software License
Number of Channels
-01 100 ch
-02 200 ch
-05 500 ch
-10 1000 ch
-20 2000 ch
Optional Features /RP Reporting/printing function
/MT Math function
/UA OPC-UA server function
* Channels can be added.
Additional monitoring PCs (clients)
ModelSuffix Code
Description
GA10CL Client License for GA10
Number of Licenses
-01 1 license
-05 5 licenses
-10 10 licenses
-50 50 licenses
Models and Suffix Codes Please contact us for the prices.
Specifications
Ethernet or Serial
Recorder Data Logger Power meter (WT series)
Aggregate data for monitoring!
GA10
Save the data all together!
Easy to read screen provides operator friendly monitoring
Acquired data can be stored on a PC.
Excel formatsupported
Hard
Drive
I/O module + GM90MB (Max. 6 modules)
GP10 (rear view) GP20 (rear view)
Main body alone:
Up to 3 I/O modules
With expansion units:
Up to 2 I/O modules +
GX90EX
Main body alone:
Up to 10 I/O modules
With expansion units:
Up to 9 I/O modules +
GX90EX
Main unit aloneGM10 +
GM90MB
I/O module + GM90MB (Max. 10 modules)
GM90PS
With sub units GM10 +
GM90MBGM90PS
GM90EX +
GM90MB
I/O module + GM90MB
(Max. 6 modules)
Up to 6 I/O modules
GX60
GX90EX + GM90MB GM90PS
84
Worldwide Business OperationsYokogawa Meters & Instruments Global Network
North & Central America
Yokogawa Corporation of America
Europe
Yokogawa Europe
South America
Yokogawa America do Sul
CIS
Yokogawa Electric CIS
Middle East & Africa
Yokogawa Middle East & AfricaASEAN
Yokogawa Engineering Asia
China
Yokogawa Shanhai Trading
Yokogawa Electric Korea
South Asia
Yokogawa India
Japan (Headquarters)
Yokogawa Meters &
Instruments Corporation
85
http://tmi.yokogawa.com/
http://www.yokogawa.com/ymi/
Search
GLOBALHOME / 0ur Businesses /
The following Web site offer a variety of information and services, such as document download, software download, user registration, e-mail news subscriptionand other.
Our Web site will help you find what you look for.
The following Web site offer a variety of information and services, such as document download, software download, user registration, e-mail news subscriptionand other.
Our Web site will help you find what you look for.
Digital OscilloscopesDigital Power AnalyzersOptical Measuring InstrumentsGenerators, Sources, Manometers etc.CalibratorClamp-on Power MeterDigital MultimeterClamp-on TesterInsulation TesterEarth TesterLeakage Current TesterIlluminance MeterThermometerPrecision Measuring InstrumentsMeters Products
Represented by:
2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750. JapanPhone: +81-422-52-6237 Facsimile: +81-422-52-6462 E-mail: [email protected]
YOKOGAWA METERS & INSTRUMENTS CORPORATION Global Sales Dept. http://tmi.yokogawa.com/
YMI-KS-MI-ME02
Subject to change without notice. [Ed: 05/b] Printed in Japan, 608(KP)All Rights Reserved, Copyright © 2011, Yokogawa Meters & Instruments Corporation
YOKOGAWA CORPORATION OF AMERICA2 Dart Road, Newnan, GA. 30265-1094 U.S.A.Phone: +1-770-253-7000 Facsimile: +1-770-254-0928
YOKOGAWA EUROPE B.V.Euroweg 2 3825 HD Amersfoort, THE NETHERLANDSPhone: +31-88-4641000 Facsimile: +31-88-4641111
YOKOGAWA SHANGHAI TRADING CO., LTD. 4F Tower D, Cartelo Crocodile Building, No.568 West Tianshan Road, Shanghai, CHINAPhone: +86-21-6239-6363 Facsimile: +86-21-6880-4987
YOKOGAWA ELECTRIC KOREA CO., LTD. C&M Sales Pangyo Office#901, Pangyo Innovalley F, 255, Pangyo-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-400, KoreaPhone: +82-2-2628-3810 Facsimile: +82-2-2628-3899
YOKOGAWA ENGINEERING ASIA PTE. LTD.5 Bedok South Road, Singapore 469270 SINGAPOREPhone: +65-6241-9933 Facsimile: +65-6241-2606
YOKOGAWA INDIA LTD. Plot No. 96. Electronic City Complex, Hosur Road, Bangalore 560100, INDIAPhone: +91-80-4158-6000 Facsimile: +91-80-2852-1441
YOKOGAWA ELECTRIC CIS LTD.Grokholskiy per. 13, Build. 2, 4th Floor, 129090, MoscowRUSSIAN FEDERATIONPhone: +7-495-737-7868 Facsimile: +7-495-737-7869
YOKOGAWA AMERICA DO SUL LTDA.Praca Acapulco, 31-Santo Amaro, Sao Paulo/SP, BRAZIL CEP-04675-190Phone: +55-11-5681-2400 Facsimile: +55-11-5681-4434
YOKOGAWA MIDDLE EAST & AFRICA B.S.C(c)P.O.BOX 10070, Manama, Building 577, Road 2516,Busaiteen 225, Muharraq, BAHRAINPhone: +973-17-358100 Facsimile: +973-17-336100
NOTICEBefore using the product, read the instruction manual carefully to ensure proper and safe operation.
nbn Elektronik Handelsgesellschaft m. b. H.Riesstraße 146, 8010 Graz | Tel. +43 316 40 28 05 | Fax +43 316 40 25 06www.nbn.at
Vertrieb für Österreich :