52
Accessories

Accessories - Elimport

Embed Size (px)

Citation preview

Accessories

Accessorieses for cabinets

Accessories

Mounting panels

Plinth

Cable entry

Cabinet baying accessories

Lifting accessories

Doors and locking elements

Cable management

Trays

Rails

Other accessories

Accessories

Doors

Rails

Mounting Panels

Cabinet dimensions Dimensions mounting panelCode

Height, H Width, L883 486883 686883 886

486686886

1283 4861283 6861283 88612831283 12861483 2861483 4861483 6861483 88614831683 1861683 2861683 4861683 6861683 88616831883 1861883 2861883 4861883 6861883 88618831883 12861883 1486

186286486686886

Front entry mounting panel for CQE, DAE, CAE

Caution: it is recommended to use appropriate gloves to handle mounting panels.

111

Mounting Panels

Cabinet dimensions Dimensions mounting panelCode

Height, H Width, L

1485

1485

1485

1485

1685

1685

1685

1685

1885

1885

1885

1885

1885

1885

Side entry mounting panel for CQE

Reinforcement cross rails for side entry mounting panelCode: RZRPCSE30

Cabinet width Code

Reinforcement cross rails for front entry mounting panels

112

Kit of support cleat angles for partial mounting panelsCode: RZAE05

Mounting kit for front entry mounting panelsCode: RAAE07

Partial mounting panels for CQE, DAE, CAE

Dimensions mounting panelCabinet width Code

Height Width

595 486

795 486

995 486

1195 486

595 686

795 686

995 686

1195 686

595 886

795 886

995 886

1195 866

Mounting Panels

113

Inward installation kit for front entry mounting panelsCode: RZAE06

Mounting panel accessories

Complementary plate for front entry mounting panels

Cabinet dimensions Complementary plate dimensionsCode

Height, H Width, L

114

Solid plinth of press-formed steel for CQE

Cabinet depth PPlinth dimensions

CodeLength L

order

Modular plinth for CQE, DAE and CAE

Plinth

Plinth height Cabinet width, L

Cabinet depth, P

300 400 500 600 800

115

Blind plinth for CQE

Cabinet depth PPlinth dimensions

CodeLength L

order

Example of a 100 mm high plinthwith vibration dampers

Example of a 200 mm high plinthwith vibration dampers

135

200

10

35

100

10

Earthquake resistant plinth for CQE and CAE

Floor clamp for modular plinthCode: RZKFP01

Plinth

Cabinet depth P Length L Code for 100 mm height

Code for 200 mm height

order

116

0 – 50 mm levelling feet for CQE and CAE

50 – 100 mm leveling feet for CQE, DAE and CAE

Code: RAA45

Code: RAA53

N.B. To be applied directly below the base of CQE and CAE enclosures or below the modular plinth for CQE, CAE and DAE.

Castors

Cabinet depth, P Code

R1A46

R1A47

R1A48

R1A49

Castors supports for CQE and CAE

Code: RZA41

Floor support accessories

117

Solid bottom for CQE and CAE enclosures

Cabinet dimensionsCode

Width, L Depth, P

Cabinet width, L Code

Bottom plates and cable glands

118

Description Code Number of cable per membrane

Max. cable section diameter (mm) Pack/pcs

1 47

4 21

9 13

Cable grommet

Cabinet width Code Openings Pack/pcs

4 2

6 2

8 2

2

Cable gland plate for CQE, DAE and CAE

Lower cable gland accessories

119

Baying accessories

Cabinet height H Code

Coupler for front entry mounting panels for CQE

Baying kit for CQECode: RZKE65

Baying reinforcement kit for CQE

Type of reinforcement Code

Back-to-back baying kit for CQE

Cabinet dimensionsCode

Height, H Width, L

Baying accessories

121

Lifting accessories

Lifting eye bolts for CQE, DAE and CAE (M12)Enclosure type Code

Lifting bracket for CQECode: RZTSE02

Lifting bars for CQEPress-formedCode: R1TSE01

Code: R1TSE03

122

Cabinet dimensions Door dimensionsNumber of doors Code

Height, H Width, L Height, A Width, B955 594 1955 794 1955 994 11155 594 11155 794 11155 994 11355 594 11355 794 11355 994 11355 1194 21355 1594 21555 394 11555 594 11555 794 11555 994 11555 1194 21755 294 11755 394 11755 594 11755 794 11755 994 11755 1194 21955 294 11955 394 11955 594 11955 794 11955 994 11955 1194 21955 1394 21955 1594 22155 294 12155 394 12155 594 12155 794 12155 994 12155 1194 2

Blank door for CQE, DAE, CAE

Doors

123

Doors

Double blank door for CQE, DAE, CAE

Cabinet dimensions Door dimensionsCode

Height, H Width, L Height, A Width, B

1355 794 R5CPE1481

1555 794 R5CPE1681

1555 994

1755 794 R5CPE1881

1755 994

1955 794

1955 994

2155 794 R5CPE2281

2155 994

Safety cross rail for CQE

Cabinet width Code

Support brackets for safety cross railsCode: RZSTS

124

Side door for CQE

Cabinet dimensionsCode

Height, H Width, L

Doors

125

Cabinet dimensions Door dimensionsCode

Height, H Width, L Height, A Width, B

955 594

955 794

955 994

1155 594

1155 794

1155 994

1355 594

1355 794

1355 994

1555 594

1555 794

1555 994

1755 594

1755 794

1755 994

1755 1194

1955 594

1955 794

1955 994

1955 1194

2155 594

2155 794

2155 994

2155 1194

Glazed door for CQE, DAE, CAE

Doors

126

Cabinet dimensions Door dimensionsCode

Height, H Width, L Height, A Width, B

1555 594

1555 794

1755 594

1755 794

1955 594

1955 794

Screen-printed glazed door for CQE, DAE, CAE

Door cross rail

Door width Code

Doors

127

Internal door for CQE, DAE, CAE

Cabinet dimensions Internal door dimensions Usable passageCode

Height, H Width, L Height, A Width, B C D

868 846 446

868 846 646

868 846 846

446

646

846

1268 1246 446

1268 1246 646

1268 1246 868

1468 1446 446

1468 1446 646

1468 1446 846

1668 1646 446

1668 1646 646

1668 1646 846

1668 1646

1868 1846 446

1868 1846 646

1868 1846 846

1868 1846

446

646

846

Doors

128

Mechanical door interlock for CQE

Description Code

Description Code

90° Door stop for CQE, DAE and CAE

180° Hinges for CQE, DAE and CAECode: R1CE248

N.B. Installation of 180° hinges instead of standard ones requires a further door drilling.

Door accessories

A B

A B A B A B

BLOCCO PORTA TIPO RZAE01 ARMADI CON APERTURA IN SEQUENZA ANTA SINGOLA

1 2 3 4

B A B A B A

4 3 2 1

B A B A B A

4 3 2 1

A B A B A B

1 2 3 4

A B

129

Locking element with swivel handle (optional)

Locking element with large escutcheon (standard provided with all doors)

Picture Description Dimensions, mmCode

Key Insert

3

8

7

8

7

Picture Description Dimensions, mmCode

Key Insert

3

8

7

7

8

Picture Description Code

Picture Description Code

Locking insertsTo be mounted instead of standard inserts

Locking insertsTo be mounted instead of standard inserts

Locking systems for enclosures

Ergonomic locking element with swivel handle (optional)Description Code

mm

Front view Rear viewSide view

Locking systems for enclosures

Corner enclosure

DimensionsCode

Plinth code for corner enclosure

Height, H Width, L Depth, P H 100 H 200

R5CQEA1855

R5CQEA1866

R5CQEA1888

131

Rear panel

Rear panel for CQE, DAE and CAE

Cabinet dimensions Rear panel dimensionsCode

Height, H Width, L Height, A Width, B

955 594

955 794

955 994

1155 594

1155 794

1155 994

1355 594

1355 794

1355 994

1355 1194

1555 394

1555 594

1555 794

1555 994

1555 1194

1755 294

1755 394

1755 594

1755 794

1755 994

1755 1194

1955 294

1955 394

1955 594

1955 794

1955 994

1955 1194

1955 1394

1955 1594

2155 294

2155 394

2155 594

2155 794

2155 994

2155 1194

132

Side panels for CQE

Cabinet dimensions Side panels dimensionsCode

Height, H Depth, P Height, A Depth, B

1361 346 R5LE1442

1361 446 R5LE1452

1561 346 R5LE1642

1561 446 R5LE1652

1561 546 R5LE1662

1761 246 R5LE1832

1761 346 R5LE1842

1761 446 R5LE1852

1761 546 R5LE1862

1761 746 R5LE1882

1761 946

1761 1146 R5LE18122

1961 246

1961 346

1961 446

1961 546

1961 746

1961 946

1961 1146

2161 246 R5LE2232

2161 346 R5LE2242

2161 446 R5LE2252

2161 546 R5LE2262

2161 746 R5LE2282

2161 946

2161 1146 R5LE22122

Side panels CQE

133

Vertical divider for CQE

Cabinet dimensionsCode

Height, H

Vertical divider for CQE

134

Top cable entry accessories

Modular top compartment for cable passage for CQE

Cabinet dimensions CodeSide panels code

Height, H Width, L Depth, P Top compartment Intermediate panel

R5SCE45 R5PDS45

R5SCE65 R5PDS65

R5SCE85 R5PDS85

R5SCE125 R5PDS125

R5SCE46 R5PDS46

R5SCE66 R5PDS66

R5SCE86 R5PDS86

R5SCE126 R5PDS126

R5SCE48 R5PDS48

R5SCE68 R5PDS68

R5SCE88 R5PDS88

R5SCE128 R5PDS128

– –

135

Cable entry accessories

Top compartment for separation/collection of cables for CQE

Top compartment dimensions Code

Height, H Width, L Depth, P Compartment Side panels

order

Cable compartment with side access for CQEFRAME

DOOR

TOP AND BOTTOM CABLE ENTRY

COMPOSITION

PROTECTION DEGREE

Cable compartment dimensionsCode

Height, H Width, L Depth, P

136

Chamber dimensions Roof cut-out dimensions Code for structure only

Code for structure, door and rear panelHeight, H Width, L Depth, P A B

139 149 R5CQE1833S R5CQE1833

139 249 R5CQE1834S R5CQE1834

139 289 R5CQE1835S R5CQE1835

139 385 R5CQE1836S R5CQE1836

139 585 R5CQE1838S R5CQE1838

239 149 R5CQE1843S R5CQE1843

239 249 R5CQE1844S R5CQE1844

239 289 R5CQE1845S R5CQE1845

239 385 R5CQE1846S R5CQE1846

239 585 R5CQE1848S R5CQE1848

139 149

139 249

139 289

139 385

139 585

239 149

239 249

239 289

239 385

239 585

139 149 R5CQE2233S R5CQE2233

139 249 R5CQE2234S R5CQE2234

139 289 R5CQE2235S R5CQE2235

139 385 R5CQE2236S R5CQE2236

139 585 R5CQE2238S R5CQE2238

239 149 R5CQE2243S R5CQE2243

239 249 R5CQE2244S R5CQE2244

239 289 R5CQE2245S R5CQE2245

239 385 R5CQE2246S R5CQE2246

239 585 R5CQE2248S R5CQE2248

Cable chamber with front access for CQEFRAME

ROOF AND BASE

BOTTOM

PROTECTION DEGREE

Cable chamber

Flanged roof

137

Cable management accessories

Adapters for connector carrier

Adapter type Code

Connector carrier for CQE

Cabinet dimensionsQuantity of connectors Code

Height, H Depth, P

138

Door tray for CQE, DAE and CAE

Door width L Code

Trays

Fixed tray and sliding tray mountable to the structure for CQE, DAE and CAE

Fixed tray code Sliding tray codeCabinet dimensions

WidthL

DepthP

MAXIMUM LOAD

139

Accessories for enclosures

Pocket for wiring diagrams, mountable to blank doors, for CQE, DAE, CAE

Door width MaterialDimensions

CodeHeight Width Depth

345445545645845

222 RPA32

Metallic pocket Plastic pocket

Omega DIN 35 rail adjustable rise

Code: RPD01

Modular desk for CQE

Cabinet widthDesk dimensions

CodeHeight Width Depth

Front rails for CQE, DAE and CAE

Cabinet width Code Max. load per pair of rails

Vertical rails for CQE, DAE and CAE

Cabinet height Code

Side rails for CQE, DAE and CAE

Cabinet depth Code Max. load per pair of rails

Rails for internal arrangement

141

Rails for internal arrangement

H30 Front perforated rail for CQE, DAE and CAE

Cabinet width Code Max. load per pair of rails

6555

35

H30 Internal perforated side rail for CQE

Cabinet depth Code Max. load per pair of rails

H30 Perforated side rail for CQE, DAE and CAE

Cabinet depth Code Max. load per pair of rails

142

Transformer support cross rail for CQE, DAE and CAE

Cabinet width Code Max. load per pair of rails

Cabinet width Code Max. load per each rail

45

6 and

Cable tie-down rail for CQE, DAE and CAE

Cabinet width Code

Rails for internal arrangement

143

19” Rack for CQE, DAE and CAE

Full 19” rack, width 800 mm

Cabinet height

Rack dimensionsCode

A B n° HE

1378 1458 31

1578 1658 35

1778 1858

1978 44

Full 19” rack, width 600 mm

Cabinet height

Rack dimensionsCode

A B n° HE

1378 1458 31

1578 1658 35

1778 1858

1978 44

144

Full centered 19” rack, width 800 mm

Cabinet height

Rack dimensionsCode

A B n° HE

1378 1458 31

1578 1658 35

1778 1858

1978 44

Full 19” rack, width 1000 mm

Cabinet height

Rack dimensionsCode

A B n° HE

1378 1458 31

1578 1658 35

1778 1858

1978 44

19” Rack for CQE, DAE and CAE

145

19” Rack for CQE, DAE and CAE

L-shaped upright for 19” rack

Cabinet height n° HE Code

24 R5MRE12

29 R5MRE14

33 R5MRE16

38 R5MRE18

42

47 R5MRE22

C-shaped upright for 19” rack

Cabinet height n° HE Code

24 R5MRCE12

29 R5MRCE14

33 R5MRCE16

38 R5MRCE18

42

47 R5MRCE22

Partial 19” rack, width 800 mm

Rack dimensionsCode

A B C n° HE

432 6 R5TIEP6

483 565 9 R5TIEP9

12 R5TIEP12

713 793 875 16 R5TIEP16

883 965 18 R5TIEP18

146

Cabinet height n° HE Code

1

88 2

3

177 4

5

266 6

7

355 8

399 9

488 11

12

Blank plate for 19” rack

Rack drawer supportCode: R5SCRK01

19” Front panel with DIN cut-outCode: R5PCDF01

482,6

465

432

132,

5

57,1

47

Accessories for 19”rack for CQE, DAE and CAE

147

Accessories for 19”rack for CQE, DAE and CAE

19” Rack frame

Cabinet height

Rack dimensionsCode

A B n° HE

1355 28

1555 33

1755 37

1955 42

2155 46

Rack arresterCode: RZAE03

AB

594

20

490465450

7.5

12.7

31.7

5

44.4

5

9.5

9.5

21,5

Mounting brackets for rack uprights

Cabinet height Code

Code: R5SFMR01

148

DAE wall mounting bracket

Cabinet depth , P Code

Wall mounting accessories

CAE wall mounting bracketCode: RZAE04

Type Code

Universal mounting brackets

RZA05

RZA06

Adjustable bracket

Range Code

RZSRP01

RZSRP02

149

Accessories for cabinets

Fluorescent lamp

Power Length, mm Code

8 W 342

13 W 574

Micro-switchCode: RAMC01

Code: RAMC02

LED lamp

Power Length, mm Code

3 W

12 led

Multiple connection cable for LED lampCode: RACCL

Accessories for cabinets

Self-tapping screws M 4.8x12Code: RAA07

Special nuts

Thread Code

M6 RAA51

M8 RAA52

RAA051

RAA52

Code Nut thread Pack/pcs

Cage nuts

Spray paint

Colour Code

RAA21

RAA24

RAA54

151

A

A-6

0

B

75

20

1515

25

P

RZPDL

RZTLE

P

B

Mounting panel

A

B

100

200

100 200

34

16

L

P - 5

0

62.5

50

30

85

25

30

Ø14

Ø9

Square 14x14

Reinforcement cross rails for PCSE mounting panels

Partial mounting panel Complementary plate for mounting panels

Plinths

PCSE Side-entry mounting panel

Drawings

78

26

20

Reinforcement cross rails for mounting panels

152

62,5 75 125 125 75 62,5

45

SAME DISTANCE FOR ALL LENGTH

45

REQUESTED LENGTH

130

50B

70

C

70

C

Hole with removablegland plate

B -

70

62,5 75 125 125 75 62,5

45

SAME DISTANCE FOR ALL LENGTH

45

REQUESTED LENGTH

130

50B

70

C

70

C

Hole with removablegland plate

B -

70

Plinth of structural steel

Side panels

Blind plinth

Rear panel

Castors support

Side door

B

A

A

B

P - 60

H -

48

Drawings

abou

t 130

153

Blank door

LH

A =

H -

132

B = L - 120

Opening: L-154O

peni

ng: H

-154

240

240

Opening: L-154Internal door: L

-120 80L

from locking to ext side door: 46

46

A

B

A

B

B

H -

219

L - 180

A

87 87

8787

Screen-printed glazed door

Top compartment for cable passage

Glazed door

Internal door

Drawings

B

LL - 100

A

P

P - 1

15

A

B

135

Ø7 mm holes every 25 mm9x9 mm square holes every 25 mm

175

L - 100L

200

Sez. A-A

only for L 1200

Sez. B-B

9x9mm sq. hole every 25 mmØ7mm hole every 25 mm

175

PP - 116

154

P

130

200 P - 120

P

P-220

115

200

L

P

A

B

L

L - 100

P

L - 100

H

2 x P

Top compartment for cables separation/collection

Cable chamber

Cable compartment

Corner enclosure

Back-to-back baying kit Baying kit

Drawings

Adhesivegasket

Joiningframe

8P

- 14

L - 148

155

AB

594

20

490465450

7.5

12.7

31.7

5

44.4

5

9.5

9.5

21,5

482,6

465

432

132,

5

57,1

47

482,6

A

465

B A

465450

490465450

680

B

465450

680

A

635

635

C

465450

680465450

870

19” Rotating rack

19” Rack frame

Panels

Drawings

156

min

55

mm

60

min

55

mm

60

19” Rack uprights

Rails

30.5

2

9

9

2022.5 17.5

30

12.5

L-155

25

75

1.5

49.8

12

24.5

25

25

49.8

58

12

24.5 25

25

59

9

9

4.25

L-101

12.55163.5

25 25

5012.5

37.5

28

22

16

28.5

25 25

35

3.5

9

9

4.25

4.25

9

9

5775

85

1.5

25L-48

57

75

25

1.5

50

113648.5

25

259

11

24

3648.5

25

25

59 4.25

L-103

34

1.5

40

17L-48

12.5

51

63.5

25

19.1

9

9

5.6

7.2

9.6

35

3.5

4.25

Drawings

465450

800

Verticalclosing plate

157

29.4 1.2

66

27.7

22.7

7

4.7

9.3

9

9

4.25

L-115

1.8

14.5

27

25 25

L-101

9 4.25

12

24.5 25

25

34

27

3027

38.5

18

30.5

1.5

12

24.5

25

25

4.25

209

1.5

L-15

7

6

4.25

42.5

25

25

20

L-101.5

36.8

8

9

18

36

66

3

30

16.5 9

18

19.8

18

9

25

342

150 23

45100

Lamps

Drawings

158

Notes