24
Advantech Class I, Division II Certified Product Offerings For Hazardous Location Application

Hazardous Location Products

Embed Size (px)

DESCRIPTION

Class I, Division 2 UL certified products available and how they work.

Citation preview

Page 1: Hazardous Location Products

AdvantechClass I, Division II Certified

Product OfferingsFor Hazardous Location Application

Page 2: Hazardous Location Products

AGENDA Class I, Division 2 Certificate

Introduction Target Market Advantech Offerings

- Key selling features

Application Stories

Page 3: Hazardous Location Products

Class I Division 2 Certification What is a “hazardous location” ? OSHA1

Areas where flammable liquids, gases or vapors or combustible dusts exist in sufficient quantities to produce an explosion or fire.

NEC2 / CEC3

An area where a potential hazard (e.g., a fire, an explosion, etc.) may exist under normal or abnormal conditions because of the presence of flammable gases or vapors, combustible dusts or ignitable fibers or flings.

1. Occupational Safety and Health Administration2. National Electrical Code3. Canadian Electrical Code

Page 4: Hazardous Location Products

Area Classification – Class Definition

Class I LocationFlammable gases/liquids/vapors Petroleum refineries,

gasoline storage Dry cleaning plants Spray finishing areas Aircraft hangars and fuel

servicing areas

Class II LocationCombustible dust Grain elevators, flour and

feed mills Magnesium or aluminum

powders Producers of starch or candies Spice-grinding plants, sugar

plants and cocoa plants Coal/carbon handling or

processing areas

Class III LocationFibers or filings Textile mills, cotton gins Cotton seed mills, flax

processing plants Plants that shape, pulverize

or cut wood and create sawdust or filings

Page 5: Hazardous Location Products

Division Definition

Division 1An explosive mixture of gas, vapor or mist is continuously present or likely to occur during normal operation.

Division 2An explosive mixture is NOT likely to occur in normal operation and may be accidentally be present.

Page 6: Hazardous Location Products

Temperature Definition

Ignition

temperature

135℃

Surface temperature 130℃

>If surface temp.

Ignition temp.

Page 7: Hazardous Location Products

Target Markets

Petroleum refining Dry clean plant Hospital Utility business Aerospace Cutting Coating & Spraying Oil & Gas Liquor factory Tank with flammable

substance

CLASS I Grain elevator Cargo ship with grain Spice-grinding mill Sugar and dessert plant Flour and feed mill Coal industry Thermal power plant Factory manufacturing or

areas store magnesium or aluminum powders

Sugar / cocoa plants

CLASS II Cotton / flax plant Wood industry

CLASS III

Page 8: Hazardous Location Products

Advantech Class I, Division 2 Certified Products Offerings

>

Industrial Monitor

Embedded Automation

Computers

Industrial Communication

Data AcquisitionModules

FPM-8151H

UNO-1140FH

UNO-1150GH

UNO-150GHE

UNO-1172AH

EKI-7000 Series: Managed Ethernet Switches

EKI-2000 Series: Unmanaged Ethernet Switches

EKI-1000 Series: Serial Device Servers, Programmable DeviceServers, Modbus Gateways, Media Converters

ADAM-4000 Series: RS-485 I/O Analog Input / Output Modules and RS-485 I/O Digital Input / Output Modules

ADAM-6000 Series: Ethernet I/O Modules

ADAM-4500 Series: Repeaters / Converters

ADAM-3000 Series: Isolated Signal Conditioning Modules

Page 9: Hazardous Location Products

Advantech Class I, Division 2 HMI: FPM-8151H

Model FPM-8151H

Display

Size (diagonal) 15” XGA

Resolution 1024 x 768

Colors 16.2M

Viewing Angel 160, 140

Luminance 350

Direct VGA Input Yes

DVI Input Yes

Touch-screen (optional) Resistive

OSD (On-Screen Display) Yes

Power Adapter (AC) 100-240 V

DV Power Input 24 VDC

Front Panel Ingress Protection NEMA4/IP65

Operating Temperature -20 ~ 60 (-4 ~ 140 )℃ ℉

Dimensions (W x H x D) 422 x 338 x 68 mm (16.61” x 13.31” x 2.68”)Certifications CID2 Group ABCD, T4

Page 10: Hazardous Location Products

Advantech Class I, Division 2 Controllers: UNO-1100H Series

Model UNO - 1140FH UNO - 1150GH / 1150GHE UNO - 1172AH

CPU EVA-X4150 486SX grade, 150 MHz LX800, 500 MHz Atom D510,

1.67 GHz Onboard RAM 64M Industrial SDRAM 256M DDR SDRAM 2 GB DDR2 SDRAMBB SRAM - - 1 MBDisplay VGA VGA VGA

Serial Ports 4 x Iso. RS-232 / 4854 x Iso. RS-485

1 × RS-2322 x RS-232 / 422 / 485

2 x RS-232 / 422 / 4852 x RS-232 (pin header)

LAN 1 x 10 / 100Base-T 2 x 10 / 100Base-T 3 x 10 / 100 / 1000Base-TUSB 2 2 4

Expansion PC / 104 (reserved) UNO-1150GH: N/AUNO-1150GHE: 1 x PCI-104, 1 x Mini PCI

1 x Mini PCIe/ 1 x Mini PCI2 x PC/104+

CF Slots 1 (internal) 1 (internal) 1 (internal)

Power Input Range 10 ~30 VDC 10 ~ 36 VDC 10~ 36 VDC

Operation Temp. -10 ~ 60° C (14 ~ 140° F) -10 ~ 60° C (14 ~ 140° F) -10 ~ 60° C (14 ~ 140° F)

Dimension 71 x 152 x 139 mm 71 x 152 x 139 mm/ 96.5 x 152 x 139 mm 85.5 x 152 x 139 mm

Certifications CID2 Group ABCD, T4A CID2 Group ABCD, T3A CID2 Group ABCD, T5

Page 11: Hazardous Location Products

Advantech Class I, Division 2 Industrial Communication

Model EKI-7758F EKI-7656C/CI EKI-7657C EKI-2728MI EKI-2525M EKI-2541M/S

Numbers of ports 8 18 10 8 5 2

10/100Base-T(X) - 16 7 - 4 1

100BaseFX - - - - 1 1

10/100/1000BaseT(X) 4 2 3 6 - -

1000Base-SX/LX/LHX/XD/ZX/EZX 4 2 3 2 - -

Certifications CID2 Group ABCD, T4

Model EKI-1351 EKI-1521 EKI-1222Ethernet Ports WLAN 802.11 b/g 2 x 10/100 Mbps (RJ45)

Serial Ports 1 x DB9 1 x RS-232/422/485 (DB9) 2 x RS-232/422/485 (DB9)

Baud Rate 50 ~ 921.6 kbps

Operating Mode Virtual COM, TCP Server/Client, UDPP2P, AT Command, RFC2217

Modbus RTU Modbus ASCII Master/Slave

Certifications CID2 Group ABCD, T4

Model EKI-1122L

Ethernet Ports 2 x 10/100 Mbps (RJ45)

Serial ports 2 x RS-232/422/485 (DB9)

CPU/RAM ARM7 80MHz/16MB SDRAM

Flash 8 MB

Certifications CID2 Group ABCD, T4

Page 12: Hazardous Location Products

Advantech Class I, Division 2Data Acquisition Modules

Model ADAM-4117 ADAM-4024 ADAM-4051 ADAM-4055 ADAM-6017Resolution 16 bits 12 bits - - 16 bits

Channel8 x differential AI(sampling rate: 10/100 Hz)

4 x AO4 x DI 16 x isolated DI 8 x isolated DO

8 x isolated DI8 x isolated AI2 x DO (sink)

Certifications CID2 Group ABCD, T5

Model ADAM-4510I ADAM-4520I ADAM-4521

Network RS-422/485 RS-232/422/485

Communication Speed 1200 ~ 115.2 Kbps

Communication Distance 1.2 km

Isolation Voltage 3000 VDC 1000 VDC

Certifications CID2 Group ABCD, T5

Model ADAM-3011

InputJ, K, T, E, S,R, B TypeThermalcouple

Output 0 ~ 10 V

Certifications CID2 Group ABCD, T5

Page 13: Hazardous Location Products

Advantech CID2 ProductsUnique Highlights 1

Cable-freeNo cable insideNo friction spark

Industrial-grade thermal design

LOW SURFACE TEMPERATURE

SPARK-FREE DESIGN

Selective electroniccomponents

USB holderHold USB from

moving

Page 14: Hazardous Location Products

Advantech CID2 ProductsUnique Highlights 2

Class I Division 2 Certification: Group ABCD Temperature Code: T3A / T4A / T5

- Maximize safety- Reduces loss incase of disaster

Page 15: Hazardous Location Products

Advantech CID2 ProductsUnique Highlights 3

Data Acquisition Module: Endures More Severe & Adverse Environments

Dual Watchdog Timer System WDT Communication WDT

Over current and temperature shutdown

Surge, EFT and ESD protection 1 KV surge 3 KV EFT 8 KV ESD

Page 16: Hazardous Location Products

Advantech CID2 ProductsUnique Highlights 4

Ethernet Switch: Passed Harsh Test of Various Vertical Markets

Redundant Power Input

• 12 ~ 48 VDC dual power inputs for preventing device broken from wrong power wiring

X-ring Technology

• Construct a steady and reliable network• Recover from network shutdown in 10ms

More Vertical Certifications

• IEC 61850• EN50155• UL508 Safety

Page 17: Hazardous Location Products

Advantech CID2 ProductsUnique Highlights 5

Controller: Designed and Tested for Severe Application

Wide temp. tolerance ( -10 ~ 60 )℃ ℃

IP40, cableless and fanless against stringent weather condition, vibration and shock from damage

Industrial-grade power design and isolated serial ports

Page 18: Hazardous Location Products

Advantech CID2 ProductsUnique Highlights 6

Integrated Hazardous Application Portfolio

Industrial Monitor

Embedded Automation Computers

Industrial Communication

Data AcquisitionModules PAC HMI/SCADA

Software

• FPM-8151H • UNO-1140FH

• UNO-1150GH

• UNO-150GHE

• UNO-1172AH

• EKI-7000 Series: Managed Ethernet Switches

• EKI-2000 Series: Unmanaged Ethernet Switches

• EKI-1000 Series: Serial Device Servers, Programmable Device Servers, ModbusGateways,MediaConverters

• ADAM-4000 Series: RS-485 I/O Analog Input/ Output Modules and RS-485 I/O Digital Input/ Output Modules

• ADAM-6000 Series: Ethernet I/O Modules

• ADAM-4500 Series: Repeaters/Converters

• ADAM-3000 Series: Isolated Signal ConditioningModules

• APAX Controller

• APAX Coupler

• APAX I/O

• ADAM-5000 Series

• WebAccess

Page 19: Hazardous Location Products

Application Stories

CID2 certified for hazardous locations 3 x LAN ports for redundancy and teaming System Diagnosis (LED, DO) PC/104+ expansion Mini PCIe for wireless expansion 8 isolated RS-485

Page 20: Hazardous Location Products

Oil & Gas Application

Production

UNO-1150GHAMD Geode LX800 Automation Computer with 3 x COM & 2 x LAN ports

Page 21: Hazardous Location Products

Storage

UNO-1172AHIntel Atom D510 Automation Computer with System Diagnosis

Oil & Gas Application

Page 22: Hazardous Location Products

Chemical Process Application

UNO-1150GHEAMD Geode™ LX DIN-rail PC with 2 x LAN Ports, 3 x COM, & PCI-104

ETHYLENEPROCESSCONTROLSYSTEM

Page 23: Hazardous Location Products

UNO-1172AHIntel Atom D510 Automation Computer withSystem Diagnosis

Liquor Industry & Automobile Painting Shop Application

LIQUORINDUSTRY APPLICATION

PAINT SHOPAPPLICATION

UNO-1150GHAMD Geode LX800 Automation Computer with 3 x COM Ports &2 x LAN Ports

Page 24: Hazardous Location Products