Tlp. (021) 26646205 - 98883072 Fax.(021) 26646826 Hp.0812 8933605 Design and specifications subject to change without notice Data Sheet A112-3400-1 Description 4...20 mA, 2-wire transmitter, HART ® communication Configurable span, unit and damping Turn down 25:1 Zero point adjustment 2-point calibration -1(0)...400 bar Gauge or absolute pressure 400% overpressure safety limit Hygienic process connections Demko EEx ia IIC T5/T6, ATEX II 1G Demko Ex N IIC T5/T6 Barbara Ex ia IIC T5/T6 FlexBar HRT is a loop powered, configurable pressure transmitter. FlexBar HRT measures the pressure by means of a polysilicon strain gauge sensor. The electronics are separated from the media by a thin diaphragm and an oil-filling. Three different oil fillings are available including a mineral oil complying with demands from FDA for use in the food and pharmaceutical industries. The electronics are located in a separate sealed housing giving FlexBar HRT superb resistance to moisture. Cable connection is via gland or plug. The HART ® communication features on-line process calibration/ adjustment and transmitter configuration. FlexBar HRT is used in food, chemical and petrochemical industries to measure absolute or gauge pressure for machine and hydraulic applications etc. The wide range of process connections together with the configurable facilities make FlexBar HRT the ideal choice for all pressure measuring applications. Hygienic process connections for a wide range of standards are avail- able for FlexBar HRT with a flush diaphragm and G1/2A male nipple. Please refer to the data sheet for FlexBar HRT Accessories. The FlexView LC-display is optional. FlexBar HRT Pressure Transmitter VIRLIE ENGINEERING Co. Mall Mega Glodok Kemayoran Lt.G Blok.D5-1 Jakarta Pusat Email. [email protected] / [email protected] Website. www.safety07.com / www.virlie.indonetwork.co.id / virliefujiyama.indonetwork.co.id

A1 Electronic Pressure

Embed Size (px)

Citation preview

Page 1: A1 Electronic Pressure

Tlp. (021) 26646205 - 98883072 Fax.(021) 26646826 Hp.0812 8933605

Design and specifi cations subject to change without notice

Data Sheet A112-3400-1

Description

4...20 mA, 2-wire transmitter,HART® communication

Confi gurable span, unit and damping

Turn down 25:1

Zero point adjustment

2-point calibration

-1(0)...400 bar

Gauge or absolute pressure

400% overpressure safety limit

Hygienic process connections

Demko EEx ia IIC T5/T6, ATEX II 1G

Demko Ex N IIC T5/T6

Barbara Ex ia IIC T5/T6

FlexBar HRT is a loop powered, confi gurable pressure transmitter. FlexBar HRT measures the pressure by means of a polysilicon strain gauge sensor. The electronics are separated from the media by a thin diaphragm and an oil-fi lling. Three different oil fi llings are available including a mineral oil complying with demands from FDA for use in the food and pharmaceutical industries.

The electronics are located in a separate sealed housing giving FlexBar HRT superb resistance to moisture. Cable connection is via gland or plug.

The HART® communication features on-line process calibration/adjustment and transmitter confi guration.

FlexBar HRT is used in food, chemical and petrochemical industries to measure absolute or gauge pressure for machine and hydraulic applications etc.

The wide range of process connections together with the confi gurable facilities make FlexBar HRT the ideal choice for all pressure measuring applications.

Hygienic process connections for a wide range of standards are avail-able for FlexBar HRT with a fl ush diaphragm and G1/2A male nipple. Please refer to the data sheet for FlexBar HRT Accessories.

The FlexView LC-display is optional.

FlexBar HRT Pressure Transmitter

VIRLIE ENGINEERING Co.Mall Mega Glodok Kemayoran Lt.G Blok.D5-1 Jakarta Pusat

Email. [email protected] / [email protected]. www.safety07.com / www.virlie.indonetwork.co.id / virliefujiyama.indonetwork.co.id

Page 2: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet A112-3400-1

Technical Data

InputMeasuring limits See "Ordering Details"

Overpressure 400% of f.r., max. 600 bar(continuously)

OutputSignal span 4...20 mA or 20...4 mA 1

2-wire, HART® communication

Output limits 3.5...23 mA 1

Characteristic Linear or customised withmax. 30 points 1

Accuracy < 0.2% f.r.

Isolation voltage 500 Vac (From housing to 4...20 mA connection)

Resolution 12 bit

Load equation RL < (VCC-6.5)/23 [kOhm]

Display (optional)Please refer to FlexView data sheet

Opto-relayVoltage, standard Max. 230 Vac

Voltage, GL-approved Max. 60 Vac

DC-voltage Max. 50 Vdc

Current, continuously Max. 50 mA

Current, pulse Max. 500 mA

Relay function Set/reset 1

Confi guring limitsSpan 4...100% of full range 1

Zero point 0...96% of full range 1

Auto zero -10...10% of full range 1

CommunicationFlexProgrammer PC-program (Windows)

2-way communication (Refer to data sheet)

HART® protocol HCF standard

Features 1 Read serial numberRead/Change user IDRead/Change confi gurationRead input signal valueRead output signal valueInput signal logging2-point sensor trimCurrent output trim

Power supplyNominal 24 Vdc

Supply voltage 6.5...35 Vdc

Effects caused by changes in power supply:

Zero point 0.005% per V

Measuring range 0.001% per V

Error handlingUp/Down scaling 23 mA/3.5 mA 1

Operational conditionsStorage temperature -40...85°C

Process temperature Standard: -30...120°CCleaning < 135°C for 15 min.Cooling neck: -30...200°C(Filling fl uid DC550)

Ambient temperature -10...70°C

Relative humidity < 98%, condensing

Protection class Plug: IP 65Gland: IP 65 + IP 66

Vibrations Lloyds Register, test 2

Shock test 100g for 10 msec.

Operational condition effectsAmbient temperature infl uence, measured at -10...70°Cand max. span:

Zero point: < 0.05% per 10K

Span: < 0.05% per 10K

Process temperature: < 0.2% per 10K

Cooling neck only: Media temperature (tm) infl uence in thetemperature interval 100...200°C:

G1/2A: 20 mbar + (tm - 100) x 2.0 mbar

DS 722: 20 mbar + (tm - 100) x 0.5 mbar

ISO 2852: 20 mbar + (tm - 100) x 0.5 mbar

3A/DN38: 20 mbar + (tm - 100) x 1.0 mbar

3A/DN76: 20 mbar + (tm - 100) x 0.5 mbar

Varivent: 20 mbar + (tm - 100) x 0.5 mbar

Transitional behaviourSwitch-on time 4 sec.

Sample time 0.5 sec.

Step response time < 1 sec.

Damping, t99 0...60 sec. (2 sec. steps) 1

Long-term drift Typ. 0.1% per year

EMC dataImmunity EN 50082-2

Emission EN 50081-2

Approval (Demko) EEx ia IIC T5/T6, ATEX II 1GApproval (Barbara) Ex ia IIC T5/T6 Supply range 6.5...30 Vdc

Internal inductivity Li < 10 µH

Internal capacity Ci < 1 nF

Barrier data U < 30 Vdc ; I < 0.1 A ; P < 0.75 W

Temperature class T1...T5: -10 < Tamb < 70°CT1...T6: -10 < Tamb < 50°C

Approval (Demko) Ex N IIC T5/T6 Temperature class T1...T5: -10 < Tamb < 70°C

T1...T6: -10 < Tamb < 50°C

Page 3: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet A112-3400-1

The mounting of the pressure sensor ensures fast response time, ex cel lent temperature compensation and high measuring accuracy. All diaphragm weldings are checked with a helium leak-tester.

FlexBar HRT can be confi gured either with a handheld HART® communicator or with the dedicated Bourdon-Haenni FlexProgrammer unit connected to a standard PC.

Unless specifi ed FlexBar HRT is supplied with a standard confi guration:Pressure at 4 mA: Minimum measuring limitPressure at 20 mA: Maximum measuring limitDamping: 0 sec.Device address: 0

Accessories for FlexBar HRT are usually supplied separately and must be assembled by the customer. However, if you prefer the accessories to be assembled from the factory prior to delivery, please order type number 81 26-950.

Having the HART® communication facilities the FlexBar HRT can be operated as a conventional 4...20 mA device, or it can be connected to other HART® devices in a 2-wire HART® network, in one of three connection methods:

Mixed-signal: Please refer to HART® literature

Point-to-point: See „Applications“

Multi-drop: See below

MaterialsHousing: Stainless steel (AISI 304/W1.4301)

Pressure sensor: Polysilicon strain gauge

Fill fl uid: Ondina, Halocarbon or DC550

Wetted parts: Acid-proof stainless steel(AISI 316L/W1.4404) or Hastelloy C

Options: PTFE-tefl on coating (Accofal 2G54)

Other coatings on request

Disposal of product and packingAccording to national laws or by returning to Bourdon-Haenni

Electrical connectionCable entry Gland PG9, PG13.5 or M20

Plug DIN 43650, form BPlug DIN 43650, form A

Approval Germanischer Lloyd (with cable type no. 81 26-940)

Note 1 Confi gurable

Master

12 mA (for 3 slaves) + HART® communication signals

4 mA 4 mA4 mA

Device 1 Device 2 Device 3

In Multi-drop mode up to 15 slaves can be connected to a 2-wire cable. Each device must have a unique device number different from 0. In case that one trans mit ter is given a device number of 0, the system will revert to Mixed-signal mode.

Multi-drop mode:

bar PSI mH2O Pascal kPa MPa

1 14.5 10.197 105 100 0.1

Technical Data

Additional Description

Measuring Units Conversion

Page 4: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet A112-3400-1

Type 4´ digit4...20 mA 4...20 mA with opto-relay 4...20 mA with HART® communication 4...20 mA with HART® communication and opto-relay

Safety 5´ digitStandard version Demko EEx ia IIC T5/T6, ATEX II 1G Demko Ex N IIC T5/T6Barbara Ex ia IIC T5/T6

Cable connection 6´ digit Gland PG13.5 Gland M20 Plug DIN 43650, form B 2 Gland PG9Plug DIN 43650, form A 2 5

Process connection position 7´ digitAt the base At the rear At the base with cooling neck At the rear with cooling neck

Diaphragm surface 8´ digitStandard Covered with Tefl on 3

Oil fi lling 9´ digitOndina (Recommended for food industry applications, max. 120°C) Halocarbon (For Oxygen measuring, max. 120°C) DC550 (Silicone oil for high temperature applications, max. 200°C)

Process connection standard 10´ digitFlush diaphragm, male nipple G1/2A PN400 AISI 316LFlush diaphragm, male nipple G1/2A PN400 Hastelloy C-276DS 722 Rotating female nut DN40 PN16 AISI 316LISO 2852 clamp DN38 PN40 AISI 316LISO 2852 clamp DN51 PN40 AISI 316L3A hygienic connection DN38 PN40 AISI 316L3A hygienic connection DN76 PN40 AISI 316LGEA Tuchenhagen Varivent PN40 AISI 316LSMS 1145 male nipple DN38 PN25 AISI 316LM44 x 1.25 male nipple, pulp and paper version PN16 AISI 316LM44 x 1.25 male nipple, hygienic version PN16 AISI 316Lø43 mm hygienic connection PN16 AISI 316LDIN 11851 Rotating female nut DN40 PN25 AISI 316LDIN 11851 Rotating female nut DN50 PN25 AISI 316LSMS 1145 Rotating female nut DN38 PN25 AISI 316LSMS 1145 Rotating female nut DN51 PN25 AISI 316L1/2“-14 NPT male nipple, ANSI/ASME B1.20.1 PN400 AISI 316L Gauge connection for external seal 4 G1/2A PN16 DIN 16288

Pressure type 11´ digitRelative pressure (bar) Absolute pressure (bar)

Pressure range 12´ digit-0.1...0.4 0...0.4 -0.4...1 0...1 -1.0...2.5 0...2.5 -1.0...6 0...6 -1.0...16 0...16 -1.0...40 0...40 -1.0...100 0...100 -1.0...400 0...400

Ordering Details - FlexBar HRT

816x xxxx xxxx

1 2 3 4

1 2 3 4

1 2 3 4 5

1 2 3 4

1 2

1 2 3

1 2 3 4 5 6 7 8 9 E F G H J K L N S

1 2

1 2 3 4 5 6 7 8

Page 5: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet A112-3400-1

Resistance Power supply FlexBar HRT pressure transmitter > 250 Ohms (or master) with FlexView display (optional)

Handheld HART® communicator, model 275

230 Vac

24 Vdc

4...20 mA

2 Not available with relay

3 P<16 bar. Also for use in food processing (FDA)

4 P<16 bar. This connection has no diaphragm and no oil fi lling. An external fl ange with seal and non-aggressive/non-conductive fi lling fl uid must be mounted.

5 Only available with process connection at the base

Screw terminals:1 & 2: 4...20 mA loop3 & 4: Opto-relay (optional)

LED, lights during auto zero adjustment

Auto Zero push button

1 & 2: Pins for connection of FlexProgrammer

ConnectorDIN 43650 B

Test terminals:A multimeter (Ri < 2 Ohms) can be connected to measure the loop current without breaking the loop.

Ground connector

Ordering Details - Notes

Electrical Connection

3 4

1 2

NoteWhen the handheld HART® communicator is used for confi guration of the FlexBar HRT, the total series resistance in the 4...20 mA loop must exceed 250 Ohms. The confi gurator must hold the device specifi c DDL to be able to address all available HART® features.

+ 1 2 -

Non-Ex-application, Point-to-point

Page 6: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet A112-3400-1

M44 x 1.25 connection with M44 x 1.25 hygienic connection M44 x 1.25 pulp/paper version cut through rotating male nipple mounted in welding part mounted in welding part

128.5

FlexBar HRT G1/2A, with gland Process connection at the base Process connection at the baseProcess connection at the base with plug. Side view with display. FrontviewSide view

Gland PG9, PG13.5 or M20

[mm] FlexView display is optional

ø86

FlexBar HRT G1/2A, with plug Process connection at the rear Cooling neck (integrated). Specify Process connection at the rear With display and plug mounting at the base or at the rear.Side view Front view Add the indicated measure to height

4535

47.5

ø43 mm connection with O-ring sealing ø43 mm connection with O-ring sealing mounted in and DN25 rotating female nut (DIN 11851) welding part and with fl ange (shown without nut)

69.5

40.5

79.5

6.1

20.5

26.4Rotating male nipple

Welding part

Leakhole

O-ring

39.415

84ø65

77.3

ø43.7

ø64

ø11.5 (4 holes)

Tefl on ring

Dimensional Drawings

Page 7: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet A112-3400-1

ø25.3

ø50.5

32

57

ø54

30

[mm]

DS 722 rotating female nut, DN40 3A hygienic, DN38 3A hygienic, DN76

ø17.5

ø2642.5 42.5

161630 30

R6

R6R6

Gauge connection for Male nipple G1/2A ISO 2852 clamp ISO 2852 clamp external seal 6 Flush diaphragm DN38 DN51

ø91

32

57

ø84

ø68

30

12

ø72.3

ø64ø50.5

GEA Tuchenhagen Varivent Male nipple 1/2-14 NPT DIN 11851 rotating female nut

DN 40 ø56 DN 50 ø86.5

31

FlexBar HRT total measure: Housing + (cooling neck) + connection

6 This connection has no diaphragm and no oil fi lling. An external fl ange with seal and non-aggressive/non-conductive fi lling fl uid must be mounted.

SMS 1145 Rotating female nut SMS 1145 Male nipple

DN 38 ø55 DN 51 ø65

30 30

DN 38 ø60 DN 51 ø70

48.5

24

Dimensional Drawings

Notes

Page 8: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet A112-3400-1

GB/

2002

-11-

01

This

dat

a sh

eet m

ay o

nly

be re

prod

uced

in fu

ll.

Zone 0/1 Safe area

4...20 mA 24 Vdc

230 Vac

FlexBar HRT FlexView display Barrier Power Supply (Optional) (Ri > 250 Ohms)

FlexBar HRT is approved by Demko for EEx ia IIC T5/T6 and ATEX II 1G according to the European standards EN 50014 and EN 50020 FlexBar HRT is approved by Barbara for Ex ia IIC T5/T6. FlexBar HRT must be installed in accordance with prevailing guidelines for zone 0 or 1, and a certifi ed, intrinsically safe zener barrier or isolation barrier with the maximum values Umax= 30 Vdc; Imax= 0.1 A ; Pmax= 0.75 W must be used.

5 8

1 2 3 4

Ex-installation, Point-to-point

FlexBar HRT is approved by Demko for Ex N IIC T5/T6 according to BS 6941:1988 for installation in zone 2 without a barrier.

Page 9: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet A112-3400-2

Description

FlexBar HRT with homogenizer connection is designed for this extreme environment and application. There are four available connections.

All wetted parts of the pressure transmitter are produced of acid-proof stainless steel.

The electronics are located in a separate sealed housing giving FlexBar HRT superb resistance to moisture and a high mechanical stability. Cable connections via gland or plug are available.

FlexBar HRT has a confi gurable damping to stabilize the output signal and the read-out during the pulsating pressure coming from the homogenizer.

The HART®communication features remote process control and supervision as well as on-line calibration and adjustment of the transmitter.

The FlexBar HRT for homogenizer is delivered with a FlexView LC-display.

FlexBar HRT for Homogenizer

Pressure transmitter 4...20mA for homogenizer

High mechanical stability, LRS test 2

Pressure ranges 0...400 bar

Temperature range -30...120°C

Acid-proof stainless steel

FlexView LC-display

Page 10: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet A112-3400-2

GB/

2002

-06-

01

This

dat

a sh

eet m

ay o

nly

be re

prod

uced

in fu

ll.

Please refer to FlexBar HRT data sheet.

Technical Data

Type 4´ digit4...20 mA4...20 mA with opto-relay4...20 mA with HART® communication4...20 mA with HART® communication and opto-relay

Cable connection 6´ digitGland PG13.5Gland M20Plug DIN 43650, form BGland PG9Plug DIN 43650, form A

Process connection 10´ digitFlush diaphragm PN400 AISI 316L/W.1.4404Flush diaphragm PN400 AISI 316L/W.1.4404Flush diaphragm PN400 AISI 316L/W.1.4404Flush diaphragm PN400 AISI 316L/W.1.4404

Version A Type number 816x 1x11 1A18 Version B Type number 816x 1x11 1B18

Version C Type number 816x 1x11 1C18 Version D Type number 816x 1x11 1D18

[mm]

80

42.5

27.5

209.45.10

80

19.212.7

0

50

38

20.114.9

0

50

38

20.114.9

0

Not included ø18

ø23.5 ø23.5

ø34.8 ø33.3

28

W x D x H95 x 45 x 28

Type number 81 26-951 for version A 5 pcs. backing ring, PTFE 5 pcs. O-ring, FPM70

Type number 81 26-952 for the versions B, C and D 5 pcs. O-ring, FPM70

ø23 ø23ø34.5ø35.8

G1 1/4ø60

Ordering Details - FlexBar HRT for Homogenizer

816x 1x11 1x18

Dimensional Drawings

1 2 3 4

1 2 3 4 5

A B C D

Page 11: A1 Electronic Pressure

1

Description

Accessories for FlexBar HRT pressuretransmitter

Clamp rings

Welding parts

Blind plugs

Reductions

Flanges

Adaptors

O-rings

Wall bracket

FlexBar HRT is a loop powered, configurable pressuretransmitter with 4...20 mA output and HART®

communication.

FlexBar HRT is used to measure absolute or gaugepressure.

A wide range of both national and international processconnections make FlexBar HRT the ideal choice forpressure measuring applications in the food, chemicaland petrochemical industries.

FlexBar HRT Accessories

Besides the fixed connections a range of replaceable,hygienic connections are available to mount on theFlexBar HRT model with a flush diaphragm and G1/2Anipple.

This data sheet holds data for accessories such aswelding parts, clamp rings etc. for FlexBar HRT.

The FlexView display is optional - technical data can befound in the specific data sheet.

3400-3

Page 12: A1 Electronic Pressure

81 26-930Flange, DN25, DIN 2527 for 816x xxxx x6xx

81 26-931Flange, DN40, DIN 2527 for 816x xxxx x6xx

81 26-932Flange, DN50, DIN 2527 for 816x xxxx x6xx

81 26-933Flange, DN80, DIN 2527 for 816x xxxx x6xx

81 26-901Clamp ring, ISO 2852, DN38/PN64

81 26-902Clamp ring, ISO 2852, DN51/PN10

81 26-903Clamp ring, ISO 2852, DN51/PN64

81 26-904Clamp ring for flange, DIN 2527, DN38/PN64(incl. spec. nut)

81 26-905Clamp ring for flange, DIN 2527, DN76/PN64(incl. spec. nut)

81 26-916Welding part, 3A/DN38, hygienic

81 26-917Welding part, 3A/DN76, hygienic

81 26-938Blind plug, 3A/DN38, hygienic

81 26-939Blind plug, 3A/DN76, hygienic

81 26-925Welding part, M44 x 1.25

81 69-G901Adaptor DIN 11851 for ø43 connection, DN40(incl. union)

81 69-G902Adaptor DIN 11851 for ø43 connection, DN50(incl. union)

81 69-G903Flange for ø43 connection mounting on 81 69-G911

81 69-G911Welding part for ø43 mm connection

81 26-920Reduction DS 228-1/ ISO 16288for 816x xxxx x1xxUnion G1/2 to nipple G1/2A

81 26-921Reduction DS 228-1/ ISO 16288for 816x xxxx x1xxUnion G1/2 to nipple G3/8A

81 26-922Reduction DS 228-1/ ISO 16288for 816x xxxx x1xxUnion G1/2 to nipple G1/4A

ø64

ø65

ø50.5

78

ø55

ø100

[mm]

32

32

ø50.5

78

ø65 ø84

15

4 holes ø11.5

Accessories for FlexBar HRT

Page 13: A1 Electronic Pressure

81 26-923M4 damping screw for the reductions(81 26-920, 81 26-921, 81 26-922)

81 26-971O-Rings (5 pcs.), NBR, DN38, FDA approved

81 26-972O-Rings (5 pcs.), EPDM, DN38, FDA approved

81 26-973O-Rings (5 pcs.), Viton, DN38, FDA approved

81 26-976O-Rings (5 pcs.), NBR, DN76, FDA approved

81 26-977O-Rings (5 pcs.), EPDM, DN76, FDA approved

81 26-978O-Rings (5 pcs.), Viton, DN76, FDA approved

81 69-G981O-Rings (5 pcs.), NBR70, M44/ø43, FDA approved

81 69-G982O-Rings (5 pcs.), EPDM70, M44/ø43, FDA approved

81 69-G983O-Rings (5 pcs.), FPM70, M44/ø43, FDA approved

81 26-962Wall bracket for FlexBar HRT

80

64

97

81 26-926Teflon seal for M44 nipple, ø34.5 x ø40.5 x 0.8

82 23-903FlexProgrammer configuration set comprises:FlexProgrammer with 9 pole RS232C cable3.5" Program diskettesBattery plugCable with test plugs

81 26-950Factory assembly of accessories

81 26-960Calibration certificate

81 26-998Material certificate 3.1.b (EN 10204) - for wetted parts

[mm]

Accessories for FlexBar HRT

Page 14: A1 Electronic Pressure

DescriptionCombiConnect is a series of hygienic, replaceableconnections in acid-proof stainless steel (W1.4404/AISI316L). The concept fits the G1/2A nipple versions ofFlexBar HRT pressure transmitter and the CombiTempPt100 sensor.The products comply with the strict demands from the foodindustry, represented by organisations such as 3A, FDAand EHEDG.It takes less than 2 minutes to mount the pressuretransmitter or Pt100 sensor on the CombiConnectconnection.CombiConnect is an entirely new concept offering highflexibility and a low stock. The connection system is theideal choice for customers measuring temperature andpressure in environments with several differentconnections.

Connection variantsDS 722: Dansk StandardDIN 11851: Deutsches Institut für

NormungSMS 1145: Sveriges Mekanförbunds

StandardcentralBS 4825 (RJT): British StandardISO 2853 (IDF) andISO 2852 (Clamp): International Standardisation

OrganisationVarivent and Tri-Clover®: Company Standards

DesignAcid-proof stainless steel, (W1.4404/AISI 316L).

Complies with the national standards DS 722, DIN 11851,

SMS 1145, BS 4825, ISO 2852 and ISO 2853.

Manufactured according to the relevant 3A Standards.

Complies with the demands in EN1672-2

Pressure range -1...25 bar

Vibrations Lloyds Register, test 2

Overpressure 400% of f.r., max. 600 bar(continuously)

Measures to be taken at hygienic mounting according to "European Hygienic Equipment Design Group"

1. Avoid blind pockets when connecting two pipe ends.

2. The gasket between nipple and union must be levelled with the surface.

3. The union nipple and the gasket must be centered in respect to each other.

4. Avoid blind pockets where media and cleaning materials can be accumulated.

O-rings0-ring Range Notes

Nitrile (NBR70) -30...100°C 1, 2

Etylene-propylene (EPDM70) -30...150°C 1

Fluorocarbon (FPM70) -20...200°C

Notes1 Complies with the demands from FDA

2 Change recommended after 50 CIP cleanings at 130°C

Disposal of product and packingAccording to national laws or by returning to Haenni.

CombiConnect - Technical Data

Hygienic Installations

CombiConnect Hygienic Replaceable Connections

Page 15: A1 Electronic Pressure

8120 9xxx1234

01

12131415

202122232425

32333435

42434445

52535455

6B6C

7U

TypeComplete connection incl. O-ring, gasket and union ring 3Welding partUnion ring 3]GasketConnection

Varivent, Tuchenhagen GEA, DN40/DN50Connection

DS 722, DN40, UnionDS 722, DN40, NippleDS 722, DN50, UnionDS 722, DN50, NippleConnection

DIN 11851, DN25, UnionDIN 11851, DN25, NippleDIN 11851, DN40, UnionDIN 11851, DN40, NippleDIN 11851, DN50, UnionDIN 11851, DN50, NippleConnection

SMS 1145, DN38,UnionSMS 1145, DN38,NippleSMS 1145, DN51,UnionSMS 1145, DN51,NippleConnection

BS 4825, DN38, UnionBS 4825, DN38, NippleBS 4825, DN51, UnionBS 4825, DN51, NippleConnection

ISO 2853, DN38, UnionISO 2853, DN38, NippleISO 2853, DN51, UnionISO 2853, DN51, NippleConnection

ISO 2852, DN38, ClampISO 2852, DN51, ClampConnection

TriClover®, 3“, Clamp

CombiConnect

81 26-955Mounting tool for O-ringDIN 11851, DN25

81 26-956Mounting tool for O-ringDIN 11851, DN40/50BS 4825, DN38/51

81 26-957Mounting tool for O-ringISO 2853 and clamp, DN38/51SMS 1145, DN38/51

81 26-965O-ring for CombiConnect connections (5 pcs.)NBR, FDA approved

81 26-966O-ring for CombiConnect connections (5 pcs.)EPDM, FDA approved

81 26-967O-ring for CombiConnect connections (5 pcs.)FPM (Viton), FDA approved

3 Not valid for nipple and clamp connections

CombiConnect Accessories

CombiConnect - Ordering Details

Page 16: A1 Electronic Pressure

DN40:ø54DN50:ø68

DN38:ø55DN51:ø65

DN38:ø54DN51:ø66.7

DN38:ø47DN51:ø60.5

DN40:ø58DN50:ø72

DN38:ø60DN51:ø70

DN38:ø58.2DN51:ø72.5

DN38:ø50.5DN51:ø64

DN25:ø44DN40:ø56

DN50:ø68.5

DN25:ø52DN40:ø65DN50:ø78

[mm]DN40/50:ø84

Clamp ISO 2852 DN38: ø50.5 Type no. 8120 916BClamp ISO 2852 DN51: ø64 Type no. 8120 916CTri-Clover® 3" ø90.9 Type no. 8120 917U

DS 722 8120 911x

DIN 11851 8120 912x

SMS 1145 8120 913x

BS 4825 (RJT) 8120 914x

ISO 2853 (IDF) 8120 915x

GEA Tuchenhagen Varivent 8120 9101

Clamp 8120 91xx

CombiConnect Connection Variants

Page 17: A1 Electronic Pressure

CombiConnect connection

1 1) Mount the O-ring in CombiConnect.

2) The sensor tube must be screwed into the CombiConnect untilthere is a 2 to 5 mm gap between the O-ring and the bottom.

3) Press CombiConnect against the mounting tool to prevent theO-ring from sliding out. Tighten the sensor tube up at 20 Nm.

4) Tighten the safety-screw up at 2 Nm.

816x xx1x x1xx Mounting tool for CombiConnect FlexBar HRT withNipple G1/2A for CombiConnect CombiConnect

(+)

+ =

CombiConnect - Mounting Instructions

42 3

2...5 mm 2 Nm

20 Nm

50...100 N2 mm

Page 18: A1 Electronic Pressure

H-3

40

0-3

-GB

/20

00

-07

-21

FlexBar HRT on the bracket for wall mounting

FlexBar HRT with M44 hygienic connectionmounted with welding part

FlexBar HRT with ø43 mm hygienic connection

Adaptor DIN 11851 for ø43 connection, DN40 (incl. union)

Adaptor DIN 11851 for ø43 connection, DN50 (incl. union)

Flange for ø43 connection mounting on a welding part

Welding part, ø65 mm for ø43 mm connection

FlexBar HRT with DN38 clamp separator

FlexBar HRT Accessories - Application Examples

Page 19: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet 3501-1

Description

4...20 mA, 2-wire transmitter,HART® communication (Optional)

Stainless steel heavy duty housingwith LC-Display (Optional)

Confi gurable span, unit, damping and linearisation

Turn down 25:1

Accuracy better than 0.1%

Zero point adjustment

2-point calibration

Ranges 0...0.1 bar to -1(0)...70 bar

Gauge or absolute pressure

High overpressure safety limit

Demko EEx d [ia] IIC T4/T6, ATEX II 1G

Demko EEx ia IIC T4/T5, ATEX II 1G

Barbara Ex d [ia] IIC T4/T6

FlexBar 3501 is a loop powered, confi gurable pressure transmitter measuring absolute or gauge pressure.

The heavy duty housing in stainless steel, AISI 316, is specifi cally designed for applications in corrosive environments and medias.

FlexBar 3501 measures the pressure by means of a ceramic, capaci-tive sensor.

The measuring sensor and the electronics are in a separate chamber eliminating the risk of pressure and media in the terminal chamber.

FlexBar 3501 is confi gurable either with a handheld HART® com-municator or with the dedicated FlexProgrammer confi guring tool connected to a PC.

On-site adjustment of span and zero point can be made in hazardous zones with 4 push buttons on the transmitter.

The HART® communication features on-line process calibration/adjustment and transmitter confi guration.

FlexBar 3501 is used in chemical and petrochemical industries as well as in power plants and pulp and paper production.

If mounted with one of the hygienic connections, with fl ush mounted ceramic measuring cell, the FlexBar 3501 is the ideal pressure trans-mitter within harsh environmental measuring applications in the food-, beverage and pharmaceutical industry.

FlexBar 3501 Pressure Transmitter

Page 20: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet 3501-1

InputMeasuring limits 0...0.1 bar to -1(0)...70 bar

Overpressure Specifi ed for each range See "Or de ring Details"

OutputNominal output 4...20 mA 1 2-wire, HART® communication

Linear output 3.5...21.5 mA

Output limits 3.5...23 mA 1

Characteristic Linear or customised with max. 30 points 1

Accuracy +/- 0.1%Including combined effects of linearity, hysteresis andrepeatability (max. turn down 1:5)

Hysteresis < 0.05%

Accuracy D/A converter < 0.05% of nominal output span

Isolation voltage > 500 Vac (From housing to 4...20 mA connection)

Resolution 14 bit

Load equation RL < (VCC-12)/23 [kOhm]

Display (optional)Type 4 digits, 7 segment LCD, and a DOT

matrix area 7 x 20 pixels

Display range -9999...+9999

Digit height 11.5 mm

Confi guring limitsURV limits 4...100% of full range 1

LRV limits 0...96% of full range 1

Adjustment limitsSpan -10...10% of read-out LSL < span < USL

Zero point -10...10% of full range

Auto zero -10...10% of full range Min. value > -1 bar rel. LSL < auto zero < USL

CommunicationFlexProgrammer PC-software (Windows) 2-way communication

HART® protocol HCF standard

Features 1 Read serial number Read/Change user ID Read/Change confi guration Read input signal value Read output signal value Input signal logging 2-point sensor trim Current output trim

Power supplyNominal 24 Vdc

Supply voltage 12...35 Vdc

Effects caused by changes in power supply:Zero point 0.005% per V (IEC 60770)

Measuring range 0.001% per V (IEC 60770)

Error handlingUp/Down scaling 1 23 mA/3.5 mA (NAMUR NE43)

Operational conditionsStorage temperature -40...85°C

Process temperature vs. type of O-ringO-ring, NBR -30...110°CO-ring, EPDM -40...120°CO-ring, VITON -20...125°C

Ambient temperature Without display -40...85°C With display -10...70°C

Relative humidity < 98%, cond. (IEC 68238)

Protection class IP 66 + IP 67

Vibrations Lloyds Reg. (IEC 60068-2-6) 5...25 Hz 4 mm ampl. 25...100 Hz 4g 100...150 Hz 2g 150...2000 Hz 1g

Shock test 100g for 10 msec.

Long term test IEC 60770

Operational condition effectsAmbient temperature infl uence, measured at -40...85°Cand p > 1.0 bar:

Zero point: < 0.1% per 10K

Span: < 0.1% per 10K

Transitional behaviourSwitch-on time < 2 sec.

Sample time < 0.25 sec.

Damping, t99 0...60 sec. (1 sec. steps) 1

Long-term drift Typ. 0.1% f.r. per year

EMC dataImmunity EN 50082-2, EN 61326

Emission EN 50081-1, EN 61326

NAMUR NE21

Approval (Demko) EEx d [ia] IIC T4/T6, ATEX II 1GApproval (Barbara) Ex d [ia] IIC T4/T6Temperature class T1...T4: -40 < Tamb < 85°C T1...T6: -40 < Tamb < 50°C

Max. supply voltage Umax= 30 Vdc

Zones Media: 0; Housing: 1

Approval (Demko) EEx ia IIC T4/T5, ATEX II 1GTemperature class T1...T4: -40 < Tamb < 85°C T1...T5: -40 < Tamb < 70°C

Barrier data U < 30 Vdc ; I < 0.1 A; P < 0.75 W

Zones Media: 0; Housing: 0

Internal inductivity 1.3 mH

Internal capacity 3 nF

Technical Data

Page 21: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet 3501-1

Additional Description

Unless specifi ed FlexBar 3501 is supplied with a stan dard confi guration:Pressure at 4 mA: Lower range limit (LSL)Pressure at 20 mA: Upper range limit (USL)Damping: 0 sec.Device address: 0

FlexBar 3501 is available with 17 different integrated process connections and with seals according to the customers wishes. The housing is 270° rotatable in respect to the process connection.

The O-ring sealing between the process connection and the sensor is available in 3 types matching different medias. Accessories for FlexBar 3501 are usually supplied separately and must be assembled by the customer.

Having the HART® communication facilities the FlexBar 3501 can be operated as a conventional 4...20 mA device, or it can be connected to other HART® devices in a 2-wire HART® network, in one of three connection methods: Mixed-signal mode, Point-to-Point mode or Multi-drop mode. Please refer to HART® literature.

The integrated 4-digit LC-display is optional.

MaterialsHousing Stainless steel (AISI 316/W1.4401)

Surface Cast, passivated

Pressure sensor Ceramic capacitive sensor (Al2O3 - 96%)

Fill fl uid None in standard versions. In diaphragm seals according to customers specifi cations.

Wetted parts Acid-proof stainless steel (AISI 316L/W1.4404)

Electrical connectionCable entry Gland M20, Polyamid, IP 68 Gland M20, Brass, IP 66

Test conditionsConfi guration LRV = 0 bar ; URV = USL

Power supply 24 Vdc

Amb. temperature 20°C +/- 2°C

Amb. pressure 860...1060 hPa

Humidity 45...75% RH

Disposal of product and packingAccording to national laws or by returning to Bourdon-Haenni

Note1 Confi gurable

Technical Data

Terms Overview

Output (mA)

pressure (bar)LSL Full range USL

LRV limits

LRV Span URV Over pres su re limit

Auto Zero

Nom

inal

out

put

Line

ar o

utpu

t

Out

put l

imits

Dow

n sc

ale

limits

U

p sc

ale

limits Transfer curve.

Turn Down 1:5 (0...14 bar).

URV limits0% 96%

4% 100%

23.0

21.5

20.0

4.0

3.5

-1 0 7 14 70 105

Nominal curve for a -1...70 bar (rel) pres su re transmitter confi gured to a Turn Down 1:1

LSL Lower Sensor Limit

USL Upper Sensor Limit

LRV Lower Range Value

URV Upper Range Value

Page 22: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet 3501-1

Confi guring

Pressure in

Span (+10%)

Zero (+10%)

Factory adjustment

Zero (-10%)

Span (-10%)

Pressure out

( I out and Display out )

FlexBar 3501 can be confi gured in three ways:

a) With the 4 push buttons.b) With a PC, the dedicated FlexProgrammer confi guring tool and the Flex-program software, version G1 or higher.c) With the HART® handheld confi gurator, model 275 (versions 3501 2xxx xxxx only).

The LRV-auto and URV-auto functions

are used to adjust the transmitter in e.g. tank level measurements:

a) Empty the tank to zero levelb) Set the LRV-auto function (output will be set to 4 mA)c) Fill the tank to the max. leveld) Set the URV-auto function (output will be set to 20 mA)

Confi guring with the push buttons

Action ResultPush button > 0.5 sec. and release Function/input valid

No action in 10 secs. Display process data No value stored

Push <M> Toggle functions

Push <E> (in Function) Accept function

Push <E> (in Input) Value stored Display process data

Push <U> Increase value

Push <D> Decrease value

Push and hold > 2 sec. Step with 0.01% of USLPush and hold > 7 sec. Step with 0.1% of USLPush and hold > 12 sec. Step with 1% of USLPush and hold > 17 sec. Step with 10% of USL

The functions of the push buttons

With display Symbol Without display SymbolMenu <Menu> Zero + <Z+>Up <Up> Zero - <Z->Down <Down> Span + <S+>Enter <Enter> Span - <S->

Functions for a transmitter with display:

ADJ Note CONF Note Zero 2 LRV Span 2 URVAuto zero 2 DampFactory LRV-auto 2 URV-auto 2

Functions for a transmitter without display:

Function <Z+> <Z-> <S+> <S-> NoteZero Up Down 2, 3Span Up Down 2, 3Auto zero Push Push 2, 4LRV-auto Push Push 2, 4URV-auto Push Push 2, 4

Notes

2 Apply reference pressure3 Measure loop current with ampere meter4 Push simultaneously

Confi guring with FlexProgrammer

Select engineering unit from: %, bar, mbar, PSI, mH2O, kPa, MPa, atm, inHG, mmHG.

Turn down 25:12-point sensor trim30-point linearisationLoggingOut-of-range valuesScaling of output currentTAG no. and notesInfo of cell type, materials, date, serial no.

Adjustment with the push buttons

Page 23: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet 3501-1

[mm]

R 81

Front view (with display) Rear View Bottom View

NoteBehind the front cover are no parts requiring user intervention. Do not remove the front cover, when the transmitter is energised.Remove the rear cover to access the terminals for the 4...20 mA connection.

30

44

46.7132

153

503525

0

Ground connection

Dimensional Drawings

140

ISO2852 clamp, DN51 (front page photo) DS722, DN40 DIN11851, DN40fl ush mounted ceramic cell fl ush mounted ceramic cell fl ush mounted ceramic cell

Flanged seal, DIN2527 form B, (see table)fl ush mounted ceramic cell

Measure DN25 DN40 DN50 DN80

A 53.8 53.8 51.8 47.8

B 18 18 20 24

C ø115 ø150 ø160 ø200

D ø85 ø110 ø125 ø160

E ø14 ø18 ø18 ø18

Holes 4 4 4 8

3A/DN76 hygienic connection GEA Tuchenhagen, varivent DN40/50fl ush mounted ceramic cell fl ush mounted ceramic cell

ED

B

C

A

32 32

ø64ø54

32

ø56

31 20

32

12

ø84

ø68

ø91

ø72.3

Page 24: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet 3501-1

Notes2 Not available with EEx d approvals

Type 5´ digit4...20 mA 4...20 mA with HART® communication Safety 6´ digit

Standard versionDemko EEx ia IIC T4/T5, ATEX II 1G Demko EEx d [ia] IIC T4/T6, ATEX II 1GBarbara Ex d [ia] IIC T4/T6 Cable connection 7´ digit

Female thread M20 - 2 pcs. Polyamid Gland M20, included Display 8´ digit

Without display Integrated, digital display O-ring 9´ digit

VitonEPDM (FDA approved)NBR

Process connection standard 10´ digitG1/2A gauge connection (DIN 16288) PN701/2“-14 NPT male nipple, ø3 mm hole PN70G1/2A male nipple, ø10 mm hole PN701/2“-14 NPT male nipple, ø10 mm hole PN70G1/2 female thread PN701/2“-14 NPT female thread PN701/2“-14 NPT male nipple, 1/4“-18 NPT, internal female thread 2 PN70DS722 rotating female nut, fl ush mount 2 DN40 PN16ISO2852 clamp, fl ush mount 2 DN51 PN403A hygienic connection, fl ush mount 2 DN76 PN40GEA Tuchenhagen Varivent, fl ush mount 2 DN40/50 PN40DIN11851 rotating female nut, fl ush mount 2 DN40 PN25Flanged seal, DIN2527 form B, fl ush mount 2 DN25 PN40Flanged seal, DIN2527 form B, fl ush mount 2 DN40 PN40Flanged seal, DIN2527 form B, fl ush mount 2 DN50 PN40Flanged seal, DIN2527 form B, fl ush mount 2 DN80 PN40G1/2A gauge connection (DIN 16288) for external or remote seal (reduced volume), PN70

Pressure type 11´ digitRelative pressure (bar) Absolute pressure (bar) Pressure range (over pressure limit) 12´ digit

-0.1...0.1 (-0.3...4) 0...0.1 (-0.3...6) -0.1...0.4 (-1...6) -0.4...1.0 (-1...10) 0...1 (-1...10)-1...4 (-1...25) 0...4 (-1...25) -1...10 (-1...40) 0...10 (-1...40) -1...20 (-1...40) 0...20 (-1...40) -1...40 (-1...60) 0...40 (-1...60)-1...70 (-1...105) 0...70 (-1...105)

Ordering Details - FlexBar 3501

3501 xxxx xxxx

1 2

1 2 4 5

1

1 2

1 2 3

1 2 3 4 5 6 8 A B C D E F G H J S

1 2

1 2 3 4 5 6 7 8 9

Page 25: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet 3501-1

Resistance Power supply FlexBar 3501 > 250 Ohms (or master) pressure transmitter

NoteWhen the HART® communicator is used for confi guration of the FlexBar 3501, the total series resistance in the 4...20 mA loop must exceed 250 Ohms. The confi gurator must hold the device specifi c DDL to be able to address all available HART® features.

230 Vac

4...20 mA 24 Vdc

Master

12 mA (for 3 slaves) + HART® communication signals

4 mA 4 mA 4 mA

Device 1 Device 2 Device 3

NoteIn Multi-drop mode up to 15 slaves can be connected to a 2-wire cable. The transmitters are „parked“ at a fi xed output of 4 mA. Each device must have a unique device number different from 0. In case that one trans mit ter is given a device number of 0, the system will revert to Mixed-signal mode.

9000 0001 Bracket for mounting on wall or 2“ pipe9000 0002 Adaptor M20 to PG13.59000 0003 Adaptor M20 to NPT 1/2“-149000 0004 Gland, Ex d, M20 x 1.5, Brass, IP 669000 0005 Blind plug, Ex d, M20 x 1.5, Brass3501 9900 Confi guration according to customers specifi cations

Accessories

Confi guring Handheld HART® communicator, model 275

Non-Ex-Application Example, Point-to-point mode

Non-Ex-Application Example, Multi-drop mode

Page 26: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet 3501-1

GB/

2002

-10-

01

This

dat

a sh

eet m

ay o

nly

be re

prod

uced

in fu

ll.FlexBar 3501 is approved by Demko for EEx d [ia] IIC T4/T6, ATEX II 1G according to the European standards EN 50014, EN 50018 and EN 50020 and by Barbara for Ex d [ia] IIC T4/T6.

Due to the heavy duty housing FlexBar 3501 is approved for EEx d and a barrier is not neccessary, provided that FlexBar 3501 is installed in accordance with prevailing guidelines for zone 0 or 1.The FlexBar 3501 can henceforth measure media classifi ed as zone 0 medias. However the housing must be installed in zone 1 or 2.

Hazardous area Safe area 230 Vac

4...20 mA 24 Vdc

FlexBar 3501 Power Supply (Ri > 250 Ohms for HART applications)

5 8

3 4

Zone 1

Zone 0

250 Ohm

FlexBar 3501 is approved by Demko for EEx ia IIC T4/T5, ATEX II 1G according to the European standards EN 50014 and EN 50020.

FlexBar 3501 must be installed in accordance with prevailing guidelines for zone 0 or 1, and a certifi ed, intrinsically safe zener barrier or isolation barrier with the maximum values Umax= 30 Vdc; Imax= 0.1 A ; Pmax= 0.75 W must be used.

Zone 0, 1 or 2 Safe area 230 Vac

4...20 mA 24 Vdc

FlexBar 3501 Power Supply (Ri > 250 Ohms for HART applications)

5 8

3 4

250 Ohm

Ex - Installation, Ex d

Ex - Installation, Ex ia

Page 27: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet A131-9901-1

Description

The FlexProgrammer is the dedicated confi guring tool for all Bourdon-Haenni Flex-products (except FlexTop 2231 Profi bus PA transmitter).

The FlexProgrammer unit is easy to connect to a stan dard PC with the 9-pole RS232C connector.

Easy to install

Operated from a standard PC

Can confi gure all Flex-products

User-friendly software with help menus

FlexProgrammer

The software is available in 6 languages having help menus, which makes it self-explanatory and easy to operate.

The selected confi guration can be stored under a fi le name determined by the user. A print facility is available for hard copy records.

Page 28: A1 Electronic Pressure

Design and specifi cations subject to change without notice

Data Sheet A131-9901-1

GB/

2002

-06-

01

This

dat

a sh

eet m

ay o

nly

be re

prod

uced

in fu

ll.

Technical Data

Supply voltageInternal DTR signal from PCOption External battery 9 V (PP3)Data input RS232C EMC data

Immunity EN 50082-1Emission EN 50081-1

82 23-903

9000 0007

The FlexProgrammer set comprises:FlexProgrammer with 1.5 m RS 232C cable with 9-pole plug3.5 inch diskettes with the Flex-program softwareBattery plugCable with test plugs

Adaptor for confi guring of FlexTop 2201, FlexTop Iso and FlexTop HRT

Environmental conditionsOperating temperature 0...50°CHumidity < 90% RH, non-condensingProtection class IP 42Disposal of product and packing

According to national laws or by returning to Bourdon-Haenni

HardwareThe FlexProgrammer can be connected to an IBM-compatible PC with the confi guration listed below: 386 processor 3.5" fl oppy drive 4 MB RAM Windows installed (3.11, 95, 98, NT, 2000, XP) A free serial RS 232C port (physical port) 2 MB free hard disk space

2 1

Note:Disconnect loop supply before connecting the FlexProgrammerto FlexTop 2201.

Flex

Prog

ram

mer

Com LPT

1 2

1 2

9 V

SoftwareThe Flex-program software must be installed on the hard disk by running the Setup.exe fi le.In the main menu the language and the COM-port can be selected. In the SETUP menu a choice between Celcius and Fahrenheit can be made.In the EDIT menu the relevant parameters for each Flex-product can be confi gured. At termination of the program the language and COM-port selections will be stored on the hard disk.

Power supplyIf the PC is unable to supply the FlexProgrammer from the serial port an external 9V (PP3) battery must be installed, using the battery plug supplied.The battery should be connected during confi guration only. Otherwise its lifetime will be reduced.

2 1

Installation

Example of application - Confi guring FlexTop 2201

Ordering Details - FlexProgrammer

Page 29: A1 Electronic Pressure

D6.901 E / 1.01Design and specifications subject to change without notice

Special Designs for Piezoresistive Pressure Transmitters

Sp

ecia

l Des

igns

Ord

erE

DE

DE

DE

DE

DE

DE

DE

DE

DE

Dco

de

505

510

513

517

518

520

522

530

541

552

O-R

ing

sea

lN

itrile

2110

XX

XX

X

Sili

cone

2111

XX

XX

Vito

n21

12X

XX

X

EP

DM

2113

XX

XX

X

No

min

al P

osi

tio

nN

P 0

*02

17X

XX

XX

XX

NP

30*

0218

XX

XX

XX

X

NP

45*

0219

XX

XX

XX

X

NP

60*

0223

XX

XX

XX

X

NP

120

0220

XX

XX

XX

X

NP

135

0221

XX

XX

XX

X

NP

150

0224

XX

XX

XX

X

NP

180

0222

XX

XX

XX

X

9223

XX

XX

XX

X

Ele

ctri

cal c

onn

ecti

on

Cab

le w

ith in

sula

ting

pla

stic

tub

e

2130

XX

XX

XX

X

Cab

le w

ith in

sula

ting

pla

stic

tub

e an

d c

onne

ctor

Ben

dix

2130

/21

32X

XX

XX

XX

Hea

t re

sist

ing

cab

le –

55°C

... 1

55°C

2133

XX

XX

XX

X

Cab

le w

ith c

onne

ctor

Ben

dix

2132

XX

XX

XX

X

9001

XX

XX

XX

XX

X

Exe

cuti

on

Exe

cutio

n fo

r ox

ygen

0764

XX

XX

XX

XX

Free

of

silic

one

0794

XX

XX

X

Tran

smis

sio

n liq

uid

Sw

eet

alm

ond

oil

1311

XX

XX

XX

Ad

just

men

t te

mp

erat

ure

9007

XX

XX

XX

X

Ordering: A 4-digit ordering code is added to the order number for the pressure transmitter:e.g. ED 510/311.211/126/2130/9001/0035 (2130: cable compr. fitts, cable with ins. plastic, cable length 3,5 m)

Mat

eria

l(S

tand

ard

-Mat

eria

l is

NB

R,

for

ED

505

VIt

on)

*Cau

tion:

Rad

iate

d h

eat

can

rise

the

tem

per

atur

e of

the

tra

nsm

itter

cas

e ov

er

the

allo

wed

80°

C.

Sp

ecifi

cally

req

uest

nom

inal

pos

ition

Sp

ecia

lly r

eque

sted

cab

le le

ngth

(follo

win

g co

de:

cab

le le

ngth

in d

m)

Tem

per

atur

e of

ad

just

ing

med

ium

(follo

win

g co

de

corr

esp

ond

ing

to t

he t

emp

erat

ure

in °

C, e

.g. 9

007/

0120

)

ED

ED

ED

ED

NP

0

NP

30N

P 6

0N

P 4

5N

P 1

20N

P 1

35N

P 1

50

NP

120

Sta

ndar

d

S._39-40_Kat.Elekt.E 18.01.2001 15:46 Uhr Seite 39

Page 30: A1 Electronic Pressure

D6.911.1 E / 1.01Design and specifications subject to change without notice

Accessories for Piezoresistive Pressure TransmittersPressure Transmitter ED 520 and ED 530Welding sleeve

Dimensions D a H Material Ordering no.

G 1⁄2 35 20 D 11737.0

Stainless steel 1.4435

G1 55 23 D 11737.2

Grooved nut according to IDF

Dimensions A E DN Material Ordering no.

48 42 1 D 11683.1

64 56 11⁄2’’ D 11683.2Stainless steel 1.4301

77 69 2’’ D 11683.3

91 83 21⁄2’’ D 11683.4

Front piece with thread

Dimensions D a b sw Material Ordering no.

G 1⁄2 9 23 27 D 11870.0

Stainless steel 1.4435

G1 15 27 41 D 11870.2

Adapter flange according to IDF PN 40

Dimensions D R H f d a t b l DN Material Ordering no.

G 1⁄2 16,45 20 33,8 25,6 29,2 2 5 6,5 1’’ D 11753.0002

47 38,6 42,7 2,5 6 8 11⁄2’’ D 11753.0104

Stainless steel 1.4435

G1 26,45 23 60,5 51,6 56,2 3 7 9,5 2’’ D 11753.0204

74 64,1 69,9 3,5 8 11 21⁄2’’ D 11753.0304

Pressure Transmitter ED 520Welding sleeve for connection without cone

Dimensions D a H Material Ordering no.

G 1⁄2 60 20.5 D 12403.0

Stainless steel 1.4435

G1 60 20.5 D 12403.1

Ø aD

H

S._41-44_Kat.Elekt.E 18.01.2001 15:47 Uhr Seite 41

Page 31: A1 Electronic Pressure

D6.911.1 E / 1.01Design and specifications subject to change without notice

Accessories for Piezoresistive Pressure Transmitters

Pressure Transmitter ED 520 and ED 530Adapter flange according to DIN 11851 (milk fitting) PN 12

Dimensions Ordering example D 11752. 02 02

Dimension chart

D d6 d7 R H g t b lDN

G 1⁄2 36 30 16,45 20 8 2,5 5 6,5 20 02

50 41 26,45 23 10 2,5 6 8,5 32 04

56 48 26,45 23 10 3,5 7 9,5 40 05

68 61 26,45 23 11 3,5 8 8,5 50 06G1

86 79 26,45 23 12 4,5 10 7,5 65 07

100 93 26,45 23 12 4,5 10 7,5 80 08

121 114 26,45 23 15 – – – 100 09

Material stainless steel 1.4435 G 1⁄2 02

G1 04

Adapter flange according to DIN 2501 PN 40, with tongue and through holes

Dimensions Ordering example D 11755. 00 04

Dimension chart

D d1 d4 d5 k hDN

411 32 75 50 6 00

411 38 80 55 8 01

414 40 90 60 10 02

414 45 95 65 15 03

414 58 105 75 20 04G1

414 68 115 852

25 05

418 78 140 100 32 06

418 88 150 110 40 07

418 102 165 125 50 08

818 122 185 145 65 09

Material Stainless steel 1.4571 G1/2 04

Grooved union nut according to DIN 11851 (milk fitting) PN 12

Dimensions D E f DN Material Ordering no.

Rd 441⁄6’’ 48 20 20 N 2400.02

Rd 581⁄6’’ 62 21 32 N 2400.04

Rd 651⁄6’’ 70 21 40 N 2400.05

Rd 781⁄6’’ 84 22 50 Stainless steel 1.4301 N 2400.06

Rd 951⁄6’’ 102 25 65 N 2400.07

Rd 1101⁄6’’ 117 29 80 N 2400.08

Rd 1301⁄6’’ 138 31 100 N 2400.10

S._41-44_Kat.Elekt.E 18.01.2001 15:47 Uhr Seite 42

Page 32: A1 Electronic Pressure

D6.911.2 E / 1.01Design and specifications subject to change without notice

Accessories for Piezoresistive Pressure Transmitters

Adapter flange

Dimensions D H R Material Ordering no.

Stainless steel 1.4435 D 11738.02

G 1⁄2 20 16,45

Hastelloy C D 11738.20

Stainless steel 1.4435 D 11738.22

G1 23 26,45

Hastelloy C D 11738.22

Pressure Transmitter ED 510Welding sleeve for ED 510/XXX.X4X

Dimensions D Material Ordering no.

G 1⁄2 Stainless steel D 12362.01.4435

Adapter for high temperature (cooling device)

Dimensions Tmed max. lT d Connection Material Ordering no.

D 11636.02

Connection dimension DRD

Box wrench

d

d

d

G1 ⁄2

’’G

1 ⁄2’’

G1 ⁄2

’’

G1 ⁄2

’’

G1 ⁄2

’’1 ⁄2 ’

’–14

-NP

T

lT

lT

lT

DIN 16288 DIN 3852

DIN 16288 DIN 16288

DIN 16288

300°C 123 40 G 1⁄2’’ D 12361.0

200°C 95 27 G 1⁄2’’ D 12361.1

150°C 68 27 G 1⁄2’’ D 12361.21

300°C 131 40 G 1⁄2’’ D 12361.2

200°C 103 27 G 1⁄2’’ D 12361.3

150°C 79 27 G 1⁄2’’ D 12361.22

300°C 125 40 1⁄2’’-14-NPT D 12361.6

200°C 97 27 1⁄2’’-14-NPT D 12361.7

150°C 70 27 1⁄2’’-14-NPT D 12361.23

Stainless steel1.4435

Stainless steel1.4435

Stainless steel1.4435

S._41-44_Kat.Elekt.E 18.01.2001 15:47 Uhr Seite 43

Page 33: A1 Electronic Pressure

D6.911.2 E / 1.01Design and specifications subject to change without notice

Accessories for Piezoresistive Pressure Transmitters

Electrical accessoriesPressure transmitters with DIN-plug

Dimensions Designation Ordering code

Cable socket connector DIN 43 650 E 6844.0

Extension cable with socket connector1) E 6084.0xxx

Extension cable with socket and plug connectors1) E 6084.2xxx

Pressure transmitters with Binder-plug

Dimensions Designation Ordering code

Cable socket connector E 13265.0

Extension cable with socket and plug connectors1) E 6085.2xxx

Extension cable with socket connector1) E 6085.0xxx

Pressure transmitters with Bendix-plug

Dimensions Designation Ordering code

Cable socket connector E 6586.1

Extension cable with socket and plug connectors1) E 6738.3xxx

Extension cable with socket connector1) E 6737.0xxx

1) Specify cable length in order.

S._41-44_Kat.Elekt.E 18.01.2001 15:47 Uhr Seite 44

Page 34: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.07

Measurement up to 1800 bar, absolute or gauge pressure

Thin film technology

Excellent long term stability

Zero adjustment as standard (±10% of range)

Welded construction – reinforced product

Modularity of electrical and hydraulic connections

Conforms to European EMC Directive, CE marked

Highly resistant to severe process conditions(≥ 10 7 pressure cycles)

Marine version (Bureau Veritas, DNV ...)

E510 with terminal strip outlet + screwed cap

Technical Data (20°C)

E510 Pressure transmitters

Measurement range Pressure (R or A): 0...60 bar to 0...1800 bar

Output signal E512: 0...10 Vdc. E513: 4...20 mA E514: 1...5 Vdc. E516: 0...20 mA

Supply voltage E512: 14...40 Vdc. E513 - E514: 11...40 Vdc.

E516: 8...40 Vdc. Option High voltage: up to 48 Vdc Low voltage: 8...32 Vdc (E513, E514)

Insulation > 100 MΩ at 100 Vdc. Option: 250 Vdc.

Maximum input current E512 - E514: 6 mA E516: < 25 mA

Load impedance (+M /-M) E512: ≥ 2,5 k Ω E514: ≥ 1 k Ω E513: RΩ ≤ (Ualim-11)/0.02 E513: RΩ ≤ (Ualim-8)/0.02 (low voltage option) E516: RΩ ≤ (Ualim-6)/0.02

CE -conformity Standards EN50082-1 and -2 (immunity) Standards EN50081-1 and -2 (emission) with

screened cable, screen connected at both ends Pressure standards 97/23/CE

Global error (linearity, hysteresis and repeatability) by reference to BFSL Typically: ±0.2% F.S. / Max.: ±0.3%F.S.

Long term stability zero : ≤ ± 0.2% F.S over 5 years sensibility : ≤ ± 0.1% over 5 years

Operating temperature Ambiant (Ta) Standard -25...+85°C Option Low T°: -40...+85°C. High T°: -25...+100°C Fluid -25...+100°C (Ta ≤ 50°C)

Storage temperature -40...+85°C

Compensated temperature range (zero and sensitivity) -10...+55°C. Option: -10...+70°C

Zero thermal drift ±0.025% F.S./°C max. Option: ±0,015% F.S./°C max.

Span thermal drift ±0.04%/°C / Option: ±0.01%/°C

Wetted parts 17-4 PH + 1.4404 (AISI 316 L) stainless steel

Standard connections Electrical: DIN 43650 connector Pressure: G1/2 Many options available

Protection rating (EN 60529) Standard: IP65 (DIN connector) Option: IP67 or IP68 (depending on connection)

Typical response time ≤ 3 ms

Vibration resistance (IEC 68-2-6) 1.5 mm (10 - 55 Hz), 20 g (55 Hz - 2 kHz)

Shock resistance (IEC 68-2-32) 25 falls from 1 m on concrete ground

Stainless steel transmitters intended for extremely diverse industrial applications: control of fluid flow, incorporation into equipment, continuous monitoring of fluid pressure, etc.

The sensing element of the E510 is based on thin film technology.

Page 35: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.07

Design and specifications subject to change without notice

Data sheet A11.07www.bourdon-haenni.com

Page 3

Ø 35

Ø 27

104

75

10

Ø6 ... Ø8

Accès aux réglages

G1/2

20

S (option)

Z

3

2 1

27

Connections Connections

kg

0.350 0.350

Connections

E513

1 : +A2 : - A3 : : Ground

E512-E514-E516

1 : +M2 : - A / - M3 : +A : Ground

0.250

10

75

102

Ø 27

28

Ø4 ... Ø6

3

2 1

27

Ø 27

80

10

Ø6.5

27

Ø 27

95

80

10

Ø6.5

27

kgkg

kg

Dimensional Drawings - Mounting Details

Standard version. P ≥ 1 barDIN 43650 plug

E513

1 : +A2 : - A3 : : Ground

E512-E514-E516

1 : +M2 : - A / - M3 : +A : Ground

kg

Connections

Access to adjustments

Option 08DIN 43650C micro plug (8 mm)

Option 22Pig tail (length 1.5 m)

E513

+A : White- A : Blue : Ground

0.300

E512-E514-E516

+M : Yellow- A / - M : Blue+A : Red : Ground

Option 23Pig tail (length 1.5 m) + PG7 Cable gland

E513

+A : White- A : Blue : Ground

E512-E514-E516

+M : Yellow- A / - M : Blue+A : Red : Ground

Page 36: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.07www.bourdon-haenni.com

Page 2 Design and specifications subject to change without notice

Data sheet A11.07

1 : Plug2 : Case3 : Seal4 : Connector5 : Nut6 : PG7 Cable gland (horizontal or vertical)

Connections

E512-E514-E516

+M : Yellow- A / - M : Blue+A : Red : Ground

E513

+A: White- A: Blue : Ground

E513

1 : +A2 : - A3 : : Ground

E512-E514-E516

1 : +M2 : - A / - M3 : +A : Ground

Connections

0.350 0.400

112

79,5

1011

1/2 NPT Ø6.5

27

27

Ø27

Ø6 ... Ø8

Ø 38

115

69

10

1

2

3

4

5

6

27

Optional accessory

Connections

E512-E514-E516

A : +AB : - A / - MC : +MD :E : GroundF :

E513

A : +AB : C : - AD :E : GroundF :

Connections

E512-E514-E516

1 : +A2 : +M3 : Ground4 : - A / - M

E513

1 : +A2 : 3 : Ground4 : - A

0.250 0.300 0.400

Cab

le le

ng

th

Connections

E513

+A : White- A : Blue : Ground

E512-E514-E516

+M : White- A / - M : Blue+A : Red : Ground

Ø 27

10

80

97

A

B

F E

D

C

27

9343

80

10

27

4

1 2

3

73

Ø 6.5

10

27

kg kg

kg kg kg

Dimensional Drawings - Mounting Details

Option 54Pig tail cable outlet with 1/2 NPT male (length 1.5 m)

Option 20Terminal strip outlet + screwed cap

Option 096 contacts HE302 plug

Option 24M12, 4 contacts plug

Option 27Submersible cable (IP68)

Page 37: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.07

Pressure range 60 100 160 250 400 600 1000 1600 1800

Measurement range 66 110 176 275 440 660 1100 1760 1980

Max. over pressure 200 200 320 500 800 800 2000 2100 2100

Burst pressure 400 400 640 1000 1600 2500 2500 2500 2500

Model 1´...3´ digitStandard Output signal 4´ digit

0...10 Vdc4...20 mA1...5 Vdc0...20 mA

Hydraulic connection 5´...6´ digitG 1/4 (P ≤ 1000 bar)G 1/2 standard1/4 NPT (P ≤ 1000 bar)1/2 NPT (P ≤ 1000 bar)9/16"-18UNF-2B female

Pressure range 7´...9´ digitSee codes in tables Pressure type 10´ digit

AbsoluteGauge

E51x xx xxx x

E51 2 3 4 6

02 03 05 06 0T

xxx

A R

Measuring Ranges (bar)

Ordering Details - E510

B29B31B33B35B38B39B41B42B1F

code Range in bar

0 + 60 A R 0 + 100 A R 0 + 160 A R 0 + 250 A R 0 + 400 A R 0 + 600 A R 0 + 1000 A R 0 + 1600 A R 0 + 1800 A R

Options

Uncoded Options (have to be listed after the code)DegreasedLightning protectionMarine versionSupply voltage (high/low)(1)

Ambient temperature (high/low)(1)

Compensated temperature range (- 10...+70°C)Zero thermal drift: ±0.015% of range/°C max.Span adjustment ±10% of rangeSpan adjustment ±50% of range (except for 1600 and 1800 bar ranges) Calibration of sensor with certificate: Q1060Thread lockingOther hydraulic connectionsAdditional length of cableStainless steel surface mounting brackets Other units: kPa (code D), MPa (code E), kg/cm² (code F), psi (code H), mbar (code N)

Coded OptionsOther electrical connections: 08.DIN 43650C micro plug (IP65 (2)) 22.Pig tail (1.5 m) (IP65) 23.Pig tail (1.5 m) + PG7 cable gland (IP65, IP67 (3)) 54.Pig tail cable outlet with 1/2 NPT male (1.5 m) (IP65) 20.Terminal strip outlet + screwed cap (IP65, IP67) 09.6 contacts HE302 plug (IP65) 24.M12, 4 contacts plug (IP65) 27.Submersible cable (IP68 version (4))

(1) see specifications for details / (2) IP65 : water spray / (3) IP67 : temporary immersion /(4) IP68 : prolonged immersion

UK/

10-2

002

Thi

s da

ta s

heet

may

onl

y be

repr

oduc

ed in

full.

Page 38: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.03

Measurement of vacuum, absolute or gauge pressure

TRANSBAR® ceramic technology

Zero adjustment as standard (±10% of range)

Welded construction – reinforced product

Modularity of electrical and hydraulic connections

Conforms to European EMC Directive, CE marked

Highly resistant to severe process conditions (≥ 107 pressure cycles)

Marine version (Bureau Veritas ...)

All stainless steel transmitter

Stainless steel transmitters intended for extremely diverse industrial applications: control of fluid flow, incorporation into equipment, continuous monitoring of fluid pressure, etc.

Based on TRANSBAR® ceramic technology, these transmitters are compatible with the majority of process fluids.

Technical data (20°C)

E910 with IP68 option

E910 Pressure Transmitter

Measurement range From 0...25 mbar to 0...600 bar Compound, gauge or absolute pressure

Output signal E912: 0...10 Vdc. E913: 4...20 mA (except -1...0 bar where -1 = 20 mA, 0 = 4 mA)

E914: 1...5 Vdc. E916: 0...20 mA

Supply voltage E912: 14...40 Vdc E913-E914: 11...40 Vdc E916: 8...40 Vdc Option High voltage up to 48 Vdc Low voltage: 8...32 Vdc (E913, E914)

Insulation > 100 MΩ at 250 Vdc. Option: 500 Vdc.

Maximum input current E912-E914: 6 mA E916: < 25 mA

Load impedance (+M / –M) E912: ≥ 2.5 k Ω E913: RΩ ≤ (Usupply-11)/0.02 E913: RΩ ≤ (Usupply-8)/0.02 (low voltage option) E916: RΩ ≤ (Usupply-6)/0.02

CE Conformity Directive 89/336 CE (EN50082-1 and -2, EN50081-1 and -2) with screened cable, screen connected at both ends

Directive 97/23/CE : 3.3 for P < 200 bar and cat 1 for P ≥ 200 bar.

Global error (linearity, hysteresis and repeatability) by reference to BFSL Typically: ±0.2% of F.S. / Max.: ±0.3% of F.S. For P ≤ 60 mbar and P= 600 bar: Typically: ±0.6% of F.S. / Max.: ±1% of F.S.

Operating temperature Ambient (Ta) -25...+85°C Option Low T°: -40...+85°C. High T°: -25...+100°C Fluid -25...+100°C (Ta ≤ 50°C)

Storage temperature -40...+85°C

Compensated temperature range (zero and sensitivity) -10...+55°C. Option: -10...+70°C

Zero thermal drift ±0.025% F.S./°C max. (except P ≤ 1 bar: ±0.06% F.S./°C) Option: ±0.015% F.S./°C max. (except P ≤ 1 bar: ±0.025% F.S./°C)

Span thermal drift Typically: ±0.01%/°C / Max.: ±0.015%/°C

Wetted parts Ceramic + stainless steel 1.4404 (316L) + NBR seal (standard) for ranges > 250 mbar and Viton® for ranges ≤ 250 mbar

Standard connections Electrical: DIN 43650 connector Pressure: G1/2 Many options available

Protection rating (EN 60529) Standard: IP65 (DIN connector) Option: IP67 or IP68 (depending on connection)

Typical response time ≤ 3 ms

Vibration resistance (IEC 68-2-6) 1.5 mm (10-55 Hz), 20 g (55 Hz to 2 kHz)

Shock resistance (IEC 68-2-32) 25 falls from 1 m on concrete ground

Page 39: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.03

Design and specifications subject to change without notice

Data sheet A11.03www.bourdon-haenni.com

Page 3

G1/2

20

Ø 41,111

7

98Ø 49, P < 250 mbar

27

Ø 27

Standard version. P ≥ 1 barDIN 43650 plug

Ø 35

Ø 27

96

67

10

Ø6 ... Ø8

G1/2

20

S

Z

3

2 1

27

Standard version for P < 1 barDIN 43650 plug

Version also used for -1...0 bar and 0...1 bar ranges with ±50% span adjustment option.

E913

1 : +A2 : - A3 : : Ground

E912E914E916

1 : +M2 : - A / - M3 : +A : Ground

Connections

0.4000.300

Option : Stainless steel surface mounting brackets

Access to adjustments

41.5

BOURDON HAENNI

kg kg

[xx] : dimensions and weight for "P < 1 bar" versions.

Ø 27

87 [

108]

72 [

93]

10

Ø6,5

27

Option 23Pig tail (length 1.5 m) + PG7 Cable gland

Option 22Pig tail (length 1.5 m)

Connections

0.350 [0.450] 0.350 [0.450]

E913

+A : White- A : Blue : Ground

E912-E914-E916

+M : Yellow- A / - M : Blue+A : Red : Ground

Option 08DIN 43650C micro plug (8 mm)

10

67 [

98]94

[11

5]

Ø 27

28

Ø4 ... Ø6

3

2 1

27

Connections

E913

1 : +A2 : - A3 : : Ground

E912-E914-E916

1 : +M2 : - A / - M3 : +A : Ground

0.250 [0.350]

Ø 27

72 [

93]

10

Ø6,5

27

Connections

E913

+A : White- A : Blue : Ground

E912-E914-E916

+M : Yellow- A / - M : Blue+A : Red : Ground

kg kg kg

Dimensional Drawings (mm) - Mounting Details

Page 40: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.03www.bourdon-haenni.com

Page 2 Design and specifications subject to change without notice

Data sheet A11.03

Ø6 ... Ø8

Ø 38

107

[128

]

61 [

82]

10

1

2

3

4

5

6

27

Connections

E912-E914-E916

+M : Yellow- A / - M : Blue+A : Red : Ground

E913

+A: White- A: Blue : Ground

104

[125

]

71,5

[92

,5]

1011

1/2 NPT Ø6,5

27

27

Ø27

E913

1 : +A2 : - A3 : : Ground

E912-E914-E916

1 : +M2 : - A / - M3 : +A : Ground

Connections

0.350 [0.450] 0.400 [0.500]

Ø 27

10

72 [

93]

89 [

110]

A

B

F E

D

C

27

85 [

106]

43

72 [

93]

10

27

4

1 2

3

Connections

E912-E914-E916

A : +AB : - A / - MC : +MD :E : GroundF :

E913

A : +AB : C : - AD :E : GroundF :

Connections

E912-E914-E916

1 : +A2 : +M3 : Ground4 : - A / - M

E913

1 : +A2 : 3 : Ground4 : - A

0.250 [0.350] 0.300 [0.400] 0.400 [0.500]

Connections

E913

+A : White- A : Blue : Ground

E912-E914-E916

+M : White- A / - M : Blue+A : Red : Ground

1065

[86

]

Ø 6,5

27

kg kg

kg kg kg

Dimensional Drawings (mm) - Mounting Details[xx] : dimensions and weight for "P < 1 bar" versions.

Option 20terminal strip outlet + screwed cap

Option 54Pig tail cable outlet with 1/2 NPT male (length 1.5 m)

1 : Plug2 : Case3 : Seal4 : Connector5 : Nut6 : PG7 Cable gland (horizontal or vertical)

Optional accessory

Option 096 contacts HE302 plug

Option 24M12, 4 contacts plug

Option 27Submersible cable (length 1.5 m)

Cab

le le

ngth

Page 41: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.03

Options

Uncoded Options (have to be listed after the code)DegreasedLightning protectionMarine versionSupply voltage (high/low)(1)

Ambient temperature (high/low)(1)

Compensated temperature range (- 10...+70°C)Zero thermal drift: ±0.015% of range/°C max.Span adjustment ±10% of rangeSpan adjustment ±50% of range (except for ranges ≤ 0...+0.25 bar and 0...+600 bar) Calibration of sensor with certificate: Q1060Thread lockingOther hydraulic connectionsAdditional length of cableStainless steel surface mounting brackets Other units: kPa (code D), MPa (code E), kg/cm² (code F), psi (code H), mbar (code N)Atmospheric pressure measurement (Range: 800...1200 mbar absolute)

Coded Options

Other electrical connections: 08.DIN 43650C micro plug (IP65 (2)) 22.Pig tail (1.5 m) (IP65) 23.Pig tail (1.5 m) + PG7 cable gland (IP65, IP67 (3)) 54.Pig tail cable outlet with 1/2 NPT male (1.5 m) (IP65) 20.Terminal strip outlet + screwed cap (IP65, IP67) 09.6 contacts HE302 plug (IP65) 24.M12, 4 contacts plug (IP65) 27.Submersible cable (IP68 version (4))

Model 1´...3´ digitStandard Output signal 4´ digit

0...10 Vdc4...20 mA1...5 Vdc0...20 mA

Hydraulic connection 5´...6´ digitG 1/4G 1/2 standard1/4 NPT1/2 NPT Sensor seal 7´ digit

NBR (Nitril) standardCR (Neoprene) (P ≥ 250 mbar)EPDM (P ≥ 250 mbar)Kalrez® (P ≥ 1 bar)FKM (Viton®) Pressure range 8´...10´ digit

See codes in tables Pressure type 11´ digit

AbsoluteGauge

Kalrez® and Viton® are registered trademarks of DuPont Dow Elastomers

Measuring Ranges

Ordering Details - E910

(1) see specifications for details / (2) IP65 : water spray / (3) IP67 : temporary immersion /(4) IP68 : prolonged immersion

E91x xx x xxx x

E91 2 3 4 6

02 03 05 06

3 4 5 7 9

xxx

A R

Pressure in mbar Pressure in bar

compound pressure — — — — — — — — -1+0 -1+0.6 -1+1.5 -1+3 -1+5 -1+9 -1+15 -1+24 -1+39 — — — — — —

pressure 25 40 60 100 160 250 400 600 1 1.6 2,5 4 6 10 16 25 40 60 100 160 250 400 600

Measurement range 27.5 44 66 110 175 275 440 660 1.1 1.75 2.75 4.4 6.6 11 17.6 27.5 44 66 110 176 275 440 660

Max. over pressure 110 110 275 500 500 1000 1000 1000 3 3 4 8 12 20 32 50 80 120 200 320 500 600 800

Burst pressure 200 200 500 1000 1000 2000 2000 2000 6 6 7 12 18 30 48 75 120 180 300 480 600 800 1000

Range in mbar 0 + 25 – R 0 + 40 – R 0 + 60 – R 0 + 100 – R 0 + 160 – R 0 + 250 A R 0 + 400 A R 0 + 600 A R

code Range in bar. Vacuum pressure

-1 + 0 – R -1 + 0.6 – R -1 + 1.5 – R -1 + 3 – R -1 + 5 – R -1 + 9 – R -1 + 15 – R -1 + 24 – R -1 + 39 – R 0 + 1 A R 0 + 1.6 A R 0 + 2.5 A R 0 + 4 A R 0 + 6 A R 0 + 10 A R 0 + 16 A R 0 + 25 A R 0 + 40 A R 0 + 60 A R 0 + 100 A R 0 + 160 A R 0 + 250 A R 0 + 400 A R 0 + 600 A R

code

B59B72B74B76B77B79B81B82B1LB15B16B18B19B20B22B24B26B27B29B31B33B35B38B39

UK/

09-2

002

Thi

s da

ta s

heet

may

onl

y be

repr

oduc

ed in

full.

N05N06N07N08N09N10N11N12

Page 42: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.04

Pressure and vacuum measurements, absolute or gauge

Ceramic, TRANSBAR® sensing element

Zero adjustment (±10% of range)

Welded construction – reinforced product

Modularity of electrical and hydraulic connections

Stainless steel flush diaphragm

Conforms to European EMC Directive, CE marked

Highly resistant to severe process conditions

Intrinsically safe versions (Y920): LCIE 99-E6074Xcertificat ; EEX ia IIC T6 or T5 approval

Marine version (Bureau Veritas, DNV ...)

Measurement range 0...1.6 bar to 0...600 bar compound pressure, gauge or absolute pressure. (according to the pressure connection)Output signal E922-Y922: 0 ...10 Vdc / E924-Y924: 1...5 Vdc E923-Y923: 4-20 mA / E926-Y926: 0...20 mA

Supply voltage E922: 14...40 Vdc Y922: 14...28 Vdc E923-E924: 11...40 Vdc Y923-Y924: 11...28 Vdc E926: 8...40 Vdc Y926: 8...28 Vdc Option High voltage: up to 48 Vdc Low voltage: 8...32 Vdc (E923, E924)

For intrinsically safe versions Y920, power supply electrical parameters device must be: Usupply ≤ 28 Vdc ; I ≤ 120 mA ; P ≤ 0.8 W

Insulation > 100 MΩ at 250 Vdc. Option: 500 Vdc

Maximum input current E922-Y922 / E924-Y924: 6 mA E926-Y926: < 25 mA

Load inpedance (+ M /-M) E922-Y922: ≥ 2,5 kΩ E924 -Y924: ≥ 1 kΩ E923: RΩ ≤ (Usupply-11)/0.02 E923: RΩ ≤ (Usupply-8)/0.02 (low voltage option)

E926: RΩ ≤ (Usupply-6)/0.02

CE -conformity Standards EN50082-1 and -2 (immunity) Standards EN50081-1 and -2 (emission) with screened cable, screen connected at both ends Pressure standards 97/23/CE

Global error (linearity, hysteresis and repeatability) by reference to BFSL Typically: ± 0.2% of F.S. / Max.: ± 0.3% of F.S. For P= 600 bar : Typically: ± 0.6% of F.S. / Max.: ± 1% of F.S.

Storage temperature - 40...+ 85°C (standard version)

Compensated temperature range (zero and sensitivity) - 10...+ 55°C. Option: -10...+ 70°C

Operating temperature

Ambiant (Ta) Standard E920 -15...+85°C Option Low T°: -40...+ 85°C / High T°: -25...+100°C Standard Y920 -25...+40°C (T6 approval) -25...+70°C (T5 approval) Fluid -25...+100°C (Ta ≤ 50°C) Option High T°-25...+150°C (Ta ≤ 50°C)

Zero thermal drift ±0.025% F.S./°C max. Option: ±0.015 % F.S./°C max

Span thermal drift typically: ±0.01%/°C-max: ±0.015%/°C

Wetted parts St. steel flush diaphragm 1.4404 (316 L) + 1 or 2 NBR o'rings

Connection Electrical: DIN 43650 connector (standard) Pressure: G1/2 (flufh diaphragm), 1 or 2 o'rings Filling oil: LRS 1, -15...+150°C (standard) LRS 5, -40...+150°C LRS 7, -20...+80°C (paint application) Many options available

Protection rating IP65 (DIN connector)(EN 60529) Option: IP67 or IP68 (depending on connection)

Typical response time ≤ 3 ms

Vibration resistance 1,5 mm (10-55 Hz), 20 g (55 Hz-2 kHz)(EN 60068-2-6)

Shock resistance 25 falls from 1 m on concrete ground(EN 60028-2-32)

Weight From 0.300 to 0.900 kg. Depending on versions.

E920 Pressure transmitter with flush diaphragm

Specifications (20°C)

An all stainless steel construction with flush diaphragm connection makes these transmitters ideally suited for measurements on viscous and heavy fluids suchs as paint, pulp and paper, and most uses in the refrigeration field.Hydraulic connections: G 1/2, G 3/4, G 1, 1/2 NPT.

Page 43: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.04

Design and specifications subject to change without notice

Data sheet A11.04www.bourdon-haenni.com

Page 3

D

Ø6 ... Ø8

Ø27

Ø30

S (option)

Z

Ø27

Ø27

Ø30

3030

20.5

20.5

Ø18 Ø18

Ø18.2

10.5

min

i

15

3232

20.5

20.5

Ø23.8 Ø23.8

Ø24

10.5

min

i

15

4141

20.5

20.5

Ø30 Ø30

Ø30.1

10.5

min

i

15

27

15 m

ini

2020

a=99

a=13

6

a a a

a

a

a

a

Ø6 ... Ø8 Ø6 ... Ø8

a a

28

a=74

Ø35

Option 54Pig tail cable outlet

with 1/2 NPT male (1.5 m)Option 08

DIN 43650C micro plugDIN 43650 connector

(standard)

Code: DG DL DK DM DF DN E5

G1/2, 1 o'ring G1/2, 2 o'rings G3/4, 1 o'ring G3/4, 2 o'ring G1, 1 o'ring G1, 2 o'ring 1/2 NPT

o'ring Ø22x2o'ring Ø27x1.5

Access to adjustments

Type B:G1/2, P > 100 barG3/4, P ≥ 2.5 bar G1, P ≥ 1.6 bar1/2 NPT, P ≥ 4 bar

Type A:G1/2 (standard), 4 ≤ P ≤ 100 bar

+A +M -A -A / -M +A Ground

White +A Blue -A -A / -M Red +A Yellow +M Ground

o'ring Ø22x2

o'ring Ø15x1.5

o'ring Ø27x1.5

o'ring Ø21x1.5

Configuration and dimensions (mm) of the transmitterElectrical connections

Transmitter body

Hydraulic connections

Option 23Pig tail + PG7 cable gland

(1.5 m)

Option 22pig tail(1.5 m)

Page 44: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.04www.bourdon-haenni.com

Page 2 Design and specifications subject to change without notice

Data sheet A11.04

D

Ø6 ... Ø8

Ø27

Ø30

S (option)

Z

Ø27

Ø27

Ø30

3030

20.5

20.5

Ø18 Ø18

Ø18.2

10.5

min

i

15

3232

20.5

20.5

Ø23.8 Ø23.8

Ø24

10.5

min

i

15

4141

20.5

20.5

Ø30 Ø30

Ø30.1

10.5

min

i

15

27

15 m

ini

2020

a=99

a=13

6

a a a

a

a

a

a

Ø6 ... Ø8 Ø6 ... Ø8

a a

28

a=74

Ø35

Option 096 contacts HE302 plug

Option 24M12 4 contacts plug

Option 27Submersible cable (IP68)

Option

Code: DG DL DK DM DF DN E5

G1/2, 1 o'ring G1/2, 2 o'rings G3/4, 1 o'ring G3/4, 2 o'ring G1, 1 o'ring G1, 2 o'ring 1/2 NPT

Body transmitter dimension according tothe electrical connection (a in mm)

(1) no access to adjustments

o'ring Ø35x1.5

Type C:high temperatureoptionT° ≤ 150°C

+A +M -A -A / -M +A Ground

White +A +M Blue -A -A / -M Red +A Ground

+A +A +M Ground -A -A / -M

+A +A -A / -M -A +M Ground

o'ring Ø35x1.5

o'ring Ø27x1.5

Option 20Terminal strip outlet +

screwed cap

a (mm) Type A Type B Type C DIN 43650 connector 74 99 136 Micro DIN 43650C connector 74 99 136 Pig tail 78.5 103.5 140.5 Pig tail + PG7 cable gland 78.5 103.5 140.5 Pig tail calble outlet with 1/2 NPT 78 103 140 Terminal strip outlet + screwed cap 113 138 175 6 contacts HE302 plug 83.5 108.5 145.5 M12, 4 contacts plug 77 102 139 Submersible cable, IP68(1) 81.5 106.5 143.5

Configuration and dimensions (mm) of the transmitter

Page 45: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.04

Options

Measuring Ranges

Ordering - E920

Model 1´...3´ digitStandard Intrinsically safe Output signal 4´ digit

0...10 Vdc4...20 mA1...5 Vdc0...20 mA

Hydraulic connection 5´...6´ digitG1/2 flush diaphragm 1 o'ring (standard)G1/2 flush diaphragm 2 o'rings (standard)G3/4 flush diaphragm 1 o'ringG3/4 flush diaphragm 2 o'ringsG1 flush diaphragm 1 o'ring G1 flush diaphragm 2 o'rings1/2 NPT flush diaphragm (without o'ring) Sensor seal 7´ digit

NBR (Nitril) standardCR (Neoprene)EPDM(3)

FKM (Viton®) Pressure range 8´...10´ digit

See codes in tables Pressure type 11´ digit

AbsoluteGauge

Viton® is registered trademarks of DuPont Dow Elastomers(3) for low temperature applications (-40°C)

x92x xx x xxx x

E92Y92 2 3 4 6

DG DL DK DM DF DN E5

3 4 5 9

xxx

A R

UK/

2002

-09

Thi

s da

ta s

heet

may

onl

y be

repr

oduc

ed in

full

Uncoded Options (have to be listed after the code)

DegreasedLightning protectionMarine versionSupply voltage (high/low)(1)

Ambient temperature (high/low)(1)

Compensated temperature range (- 10...+70°C)Zero thermal drift: ±0.015% of range/°C max.Span adjustment ±10% of rangeSpan adjustment ±50% of range (except for 0 +1.6 and 0 + 600 bar) Calibration of sensor with certificate: Q1060Other hydraulic connectionsAdditional length of cableFilling oil: LRS5, LRS7Stainless steel surface mounting brackets Other units: kPa (code D), MPa (code E), kg/cm² (code F), psi (code H), mbar (code N)

Pressurerange

compound -1+0.6(1) -1+1.5(2) -1+3 -1+5 -1+9 -1+15 -1+24 -1+39 — — — — — —

pressure 1.6(1) 2.5(2) 4 6 10 16 25 40 60 100 160 250 400 600

Measurement range 1.75 2.75 4.4 6.6 11 17.6 27.5 44 66 110 176 275 440 660

Max. over pressure 3 4 8 12 20 32 50 80 120 200 320 500 600 800

Burst pressure 6 7 12 18 30 48 75 120 180 300 480 600 800 1000(1) G 1 connection only(2) G 3/4 and G 1 connections only

code Range in barVacuum pressure, Pressure

-1 + 0.6(1) – R -1 + 1.5(2) – R -1 + 3 – R -1 + 5 – R -1 + 9 – R -1 + 15 – R -1 + 24 – R -1 + 39 – R 0 + 1.6(1) A R 0 + 2.5(2) A R 0 + 4 A R 0 + 6 A R 0 + 10 A R 0 + 16 A R 0 + 25 A R 0 + 40 A R 0 + 60 A R 0 + 100 A R 0 + 160 A R 0 + 250 A R 0 + 400 A R 0 + 600 A R

(1) G 1 connection only(2) G3/4 and G 1 connections only

Coded OptionsOther electrical connections: 08. DIN 43650C micro plug (IP65 (2)) 22. Pig tail (1.5 m) (IP65) 23. Pig tail (1.5 m) + PG7 cable gland (IP65, IP67 (3)) 54. Pig tail cable outlet with 1/2 NPT male (1.5 m) (IP65) 20. Terminal strip outlet + screwed cap (IP65, IP67) 09. 6 contacts HE302 plug (IP65) 24. M12, 4 contacts plug (IP65) 27. Submersible cable (IP68 version (4))

(1) see specifications for details / (2) IP65: water spray / (3) IP67: temporary immersion / (4) IP68: prolonged immersion

B72B74B76B77B79B81B82B1LB16B18B19B20B22B24B26B27B29B31B33B35B38B39

Page 46: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.05

Stainless steel 1.4404 (316L) flush diaphragmMeasurement of vacuum, absolute or gauge pressureTRANSBAR® ceramic technologyZero adjustment as standard (±10% of range)Welded construction – reinforced productVarious types of pressure ports : CLAMP, SMS, DIN , or homogeneizer (0...60 bar to 0...400 bar)Modularity of electrical and hydraulic connectionsConforms to European EMC Directive, CE marked Highly resistant to severe process conditionsIntrinsically safe versions (Y930) : LCIE 99-E6074X certificat ; EEX ia IIC T6 or T5 approval approval (option)

Measurement range 0...0.25 bar to 0...40 bar Compound, gauge or absolute pressure 0...60 bar to 0...400 bar homogeneization version

Output signal E932 - Y932 : 0...10 Vdc / E934 - Y934 : 1...5 Vdc E933 - Y933 : 4...20 mA / E936 - Y936 : 0...20 mA

Supply voltage E932 : 14...40 Vdc Y932 : 14...28 Vdc E933 - E934 : 11...40 Vdc Y933 - Y934 : 11...28 Vdc E936 : 8...40 Vdc Y936 : 8...28 Vdc Option High voltage : up to 48 Vdc Low voltage : 8...32 Vdc (E933, E934)

For intrinsically safe versions Y930, power supply electrical parameters device must be : Ualim ≤ 28 Vdc ; I ≤ 120 mA ; P ≤ 0.8 W

Insulation > 100 MΩ at 250 Vdc. Option 500 Vdc

Maximum input current E932 - Y932 / E934 - Y934 : 6 mA E936 - Y936 : < 25 mA

Load impedance (+ M / - M) E932 - Y932 : ≥ 2.5 kΩ E934 -Y934 : ≥ 1 kΩ E933: RΩ ≤ (Usupply-11)/0.02 E933: RΩ ≤ (Usupply-8)/0.02 (low voltage option) E936: RΩ ≤ (Usupply-6)/0.02

CE -conformity Standards EN50082-1 and -2 (immunity) Standards EN50081-1 et -2 (emission) with sreened cable, screen connected ar both ends Pressure standards 97/23/CE

Protection rating IP65 (DIN connector)(EN 60529) Option : IP67 or IP68 (depending on connection)

Global error (linearity, hysteresis and repeatability) by reference to BFSL Typ.: ±0.2% F.S. / Max.: ±0.3% F.S.

Compensated temperature range (zero and sensitivity) - 10...+55°C. Option : - 10...+70°C

Operating temperature

Ambient (Ta) Standard E930 - 15...+85°C High T° option - 15...+100°C Standard Y930 - 15...+40°C (T6 approval) - 15...+70°C (T5 approval) Fluid - 15...+100°C (Ta ≤ 50°C) High T° option - 15...+150°C (Ta ≤ 50°C) Sterilizing 140°C max for 30 minutes Storage - 40...+85°C

Zero thermal drift ±0.025% FS/°C max. Option : ±0.015 % FS/°C max ±0.04% FS/°C max. for P < 1 bar

Span thermal drift Typ. : ±0.01%/°C - Max : ±0.015%/°C

Wetted parts Stainless steel 1.4404 (316L) flush diaphragm

Connections Electrical : DIN 43650 connector (standard) Pressure : Clamp, DIN, SMS, welded conical threaded nipple. Filling oil (FDA approved) : LRS1, -15...+150°C (standard) Many options available

Typical response time ≤ 3 ms

Vibration resistance 1.5 mm (10 - 55 Hz), 20 g (55 Hz - 2 kHz)(EN 60068-2-6)

Shock resistance 25 falls from 1 m on concrete ground(EN 60028-2-32)

Weight From 0.300 to 1.5 kg depending on versions

E930 Transmitter for sanitary use

Technical Data (20°C)

The hygiene flush diaphragm transmitters of the E930/Y930 series are ideally suited to fulfill the pressure measurement requirements of the food, dairy and pharmaceutical industries among others.The cleanliness requirements of the food processing industry have dictated the "hygienic" design of these transmitters. They can also withstand without damage the various cleaning phases specific to these industries : sterilizing cycles, autoclaving and steam flushing.

Page 47: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.05

Design and specifications subject to change without notice

Data sheet A11.05www.bourdon-haenni.com

Page 3

Type B :high temperatureoptionT° ≤ 150°CAccess to adjustments

Type A :G1/2 standardP ≥ 1 bar

Type C :P < 1 bar

Option 08DIN 43650C micro plug

DIN 43650 connector(standard)

CLAMP ISO 2852 DIN 11851FF DIN 11851FL SMS 1145FF SMS 1145FL DR0 DR2 DR8 Homogeneizer 622 Homogeneizer 623 2.5 ≤ P ≤ 40 bar 0.6 ≤ P ≤ 40 bar 7 ≤ P ≤ 400 bar 60 ≤ P ≤ 600 bar 60 ≤ P ≤ 600 bar

Configuration and dimensions (mm) of the transmitter

Electrical connections

Transmitter body

Hydraulic connections

E/Y933 E/Y932/4/6 E/Y933 E/Y932/4/6 E/Y933 E/Y932/4/6

E/Y933 E/Y932/4/6

E/Y933 E/Y932/4/6E/Y933 E/Y932/4/6

Ø6 ... Ø8 Ø6 ... Ø8

D

Ø6 ... Ø8

Ø27

S (option)

Z

Ø27

a=10

5

a a

a a a

a

a

a

a

28

a=68

Ø35

Ø41,1

Ø41,1

a=94

a=12

2

41

30

Bar

2.5 ≤ P < 40 Bar

Bar Bar

Bar

39

47

53 53 53

3030

21

34

52 52

18 18

43.9 G1/2G11/4

G150

1

2

3

1

2

4

1

2

1

2

4

1

2

5 5

1

2

1

2

3

4

5

0.4 ≤ P < 40

0.25 ≤ P < 40

0.6 ≤ P ≤ 40

0.4 ≤ P ≤ 40

0.25 ≤ P ≤ 40

0.6 ≤ P ≤ 40

0.4 ≤ P ≤ 40

0.25 ≤ P ≤ 40

0.4 ≤ P ≤ 40

0.25 ≤ P ≤ 40 0.4 ≤ P ≤ 40

0.25 ≤ P ≤ 40

+A +M -A -A / -M +A

Ground

White +A Blue -A -A / -M Red +A Yellow +M Ground

Connection accessories

Option 54Pig tail cable outlet

with 1/2 NPT male (1.5 m)

Option 23Pig tail +

PG7 cable gland (1.5 m)

Option 22pig tail(1.5 m)

Page 48: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.05www.bourdon-haenni.com

Page 2 Design and specifications subject to change without notice

Data sheet A11.05

Especially dedicated to food, chemistry,

pharmaceutical industries

Option

+A +M -A -A/-M +A Masse

Blanc +A +M Bleu -A -A / -M Rouge +A Tresse

+A +A +M Masse -A -A / -M

+A +A -A/-M -A +M

Masse

Option 20Terminal strip outlet +

screwed cap

Option 096 contacts HE302 plug

Option 24M12 4 contacts plug

Option 27Submersible cable (IP68)

Type D :P < 1 barHigh temperatureoptionT° ≤ 150°C

Seal (EPDM)

Endpiece

Collar

Nut Welded nipple

Connection accessories are uncoded options (have to be listed after the code number)

CLAMP ISO 2852 DIN 11851FF DIN 11851FL SMS 1145FF SMS 1145FL DR0 DR2 DR8 Homogeneizer 622 Homogeneizer 623 2.5 ≤ P ≤ 40 bar 0.6 ≤ P ≤ 40 bar 7 ≤ P ≤ 400 bar 60 ≤ P ≤ 600 bar 60 ≤ P ≤ 600 bar

Configuration and dimensions (mm) of the transmitter

(1) no access to adjustments

Body transmitter dimension according to the electrical connection (a in mm)

a (mm) Type A Type B Type C Type D DIN 43650 connector 68 105 94 122 Micro DIN 43650C connector 68 105 94 122 Pig tail 72.5 109.5 98.5 126.5 Pig tail + PG7 cable gland 72.5 109.5 98.5 126.5 Pig tail cable outlet with 1/2 NPT 72 109 98 126 Terminal strip outlet + screwed cap 107 144 133 161 6 contacts HE302 plug 77.5 114.5 103.5 131.5 M12, 4 contacts plug 71 108 97 125 Submersible cable, IP68(1) 75.5 112.5 101.5 129.5

E/Y933 E/Y932/4/6 E/Y933 E/Y932/4/6 E/Y933 E/Y932/4/6

E/Y933 E/Y932/4/6

E/Y933 E/Y932/4/6E/Y933 E/Y932/4/6

Ø6 ... Ø8 Ø6 ... Ø8

D

Ø6 ... Ø8

Ø27

S (option)

Z

Ø27

a=10

5

a a

a a a

a

a

a

a

28

a=68

Ø35

Ø41,1

Ø41,1

a=94

a=12

2

41

30

Bar

2.5 ≤ P < 40 Bar

Bar Bar

Bar

39

47

53 53 53

3030

21

34

52 52

18 18

43.9 G1/2G11/4

G150

1

2

3

1

2

4

1

2

1

2

4

1

2

5 5

1

2

1

2

3

4

5

0.4 ≤ P < 40

0.25 ≤ P < 40

0.6 ≤ P ≤ 40

0.4 ≤ P ≤ 40

0.25 ≤ P ≤ 40

0.6 ≤ P ≤ 40

0.4 ≤ P ≤ 40

0.25 ≤ P ≤ 40

0.4 ≤ P ≤ 40

0.25 ≤ P ≤ 40 0.4 ≤ P ≤ 40

0.25 ≤ P ≤ 40

Page 49: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.05

Options

Measuring Ranges (bar)

Ordering Details - E930

Model 1´...3´ digitStandard Intrinsically safe Output signal 4´ digit

0...10 Vdc4...20 mA1...5 Vdc0...20 mA

Hydraulic connection 5´...7´ digitCLAMP ISO DN 25CLAMP ISO DN 38CLAMP ISO DN 51SMS FF DN 38SMS FF DN 51 SMS FL DN 38 + nutSMS FL DN 51 + nut DIN FF DN 32DIN FF DN 40DIN FF DN 50DIN FL DN 32 + nutDIN FL DN 40 + nutDIN FL DN 50 + écrouDR0 (G1 with conical threading)DR2 + nutDR8 (G1/2 with conical threading)Homogeneization version with nutHomogeneization version with flange Pressure range 8´...10´ digit

See codes in tables Pressure type 11´ digit

AbsoluteGauge

x93x xx x xxx x

E93Y93 2 3 4 6

125 138 151 238 251 338 351 432 440 450 532 540 550 DR0 DR2 DR8 622 623

xxx

A R

Uncoded Options (have to be listed after the code) Coded Options

Pressurerange

compound — — — -1+0 -1+0.6 -1+1.5 -1+3 -1+5 -1+9 -1+15 -1+24 -1+39 — — — — — —

pressure 0.25 0.4 0.6 1 1.6 2.5 4 6 10 16 25 40 60 100 160 250 400 600

Measurement range 0.275 0.44 0.66 1.1 1.75 2.75 4.4 6.6 11 17.6 27.5 44 66 110 176 275 440 660

Max. over pressure 1 1 1 3 3 4 8 12 20 32 50 80 120 200 320 500 600 800

Burst pressure 2 2 2 6 6 7 12 18 30 48 75 120 180 300 480 600 800 1000

Lightning protectionSupply voltage (high/low)(1)

Ambient temperature (high/low)(1)

Compensated temperature range (- 10...+70°C)Zero thermal drift: ±0.015% of range/°C max.Span adjustment ±10% of rangeSpan adjustment ±50% of range (except for P ≤ 1 bar) Calibration of sensor with certificate: Q1060Stainless steel surface mounting bracketsOther hydraulic connections (Micro-CLAMP DN 17.2, ...)Additional length of cableOther units: kPa (code D), MPa (code E), kg/cm² (code F), psi (code H), mbar (code N)

approval

Other electrical connections: 08. DIN 43650C micro plug (IP65 (2)) 22. Pig tail (1.5 m) (IP65) 23. Pig tail (1.5 m) + PG7 cable gland (IP65, IP67 (3)) 54. Pig tail cable outlet with 1/2 NPT male (1.5 m) (IP65) 20. Terminal strip outlet + screwed cap (IP65, IP67) 09. 6 contacts HE302 plug (IP65) 24. M12, 4 contacts plug (IP65) 27. Submersible cable (IP68 version (4))

(1) see specifications for details / (2) IP65: water spray / (3) IP67: temporary immersion / (4) IP68: prolonged immersion

Code Range in bar.Vacuum pressure. Pressure

B59 -1 + 0 B72 -1 + 0.6 B74 -1 + 1.5 B76 -1 + 3 B77 -1 + 5 B79 -1 + 9 B81 -1 + 15 B82 -1 + 24 B1L -1 + 39 B10 0 + 0.25 B11 0 + 0.4 B12 0 + 0.6 B15 0 + 1 B16 0 + 1.6 B18 0 + 2.5 B19 0 + 4 B20 0 + 6 B22 0 + 10 B24 0 + 16 B26 0 + 25 B27 0 + 40

B29 0 + 60 B31 0 + 100 B33 0 + 160 B35 0 + 250 B38 0 + 400 B39 0 + 600

See in the central pages the pressure compatibilities charts according to the hydraulic connection

UK/

2002

-09

Thi

s da

ta s

heet

may

onl

y be

repr

oduc

ed in

full

Page 50: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.06

TRANSBAR® technologyExcellent long term stabilityWelded construction - reinforced productConforms to European EMC Directive, CE markedProduct identification laser etched on caseIntrinsically safe versions (Y940) : LCIE 99-E6074X certificate ; EEX ia IIC T6 or T5 approvalMarine version (Bureau Veritas, DNV ...)

Protective capLightning protectionMarine versionSupply voltage (high/low)(1)

Compensated temperature range (from -10...+70°C)Zero thermal drift : ±0.015 % of range/°C max.Cell o'ring : Viton®

Additional length or other material of cable Other ranges and unitsCleat with built-in anchor (100 daN)

Viton® is registered trademark of DuPont Dow Elastomers(1) see specifications for details

Measurement range Gauge pressure : 0...2.5 to 0...160mH2O

Output signal E942 - Y942 : 0...10 Vdc / E944 - Y944 : 1...5 Vdc E943 - Y943 : 4...20 mA / E946 - Y946 : 0...20 mA

Supply voltage E942 : 14...40 Vdc Y942 : 14...28 Vdc E943 - E944 : 11...40 Vdc Y943 - Y944 : 11...28 Vdc E946 : 8...40 Vdc Y946 : 8...28 Vdc Option High voltage: up to 48 Vdc Low voltage: 8...32 Vdc (E943, E944)

For intrinsically safe version Y940, power supply must be : Usupply ≤ 28 Vdc ; I ≤ 120 mA ; P ≤ 0.8 W

Insulation > 100 MΩ at 250 Vdc. Option: 500 Vdc

Maximum input current E942 - Y942 / E944 - Y944 : 6 mA E946 - Y946 : < 25 mA

Load impedance (+ M / - M) E942 - Y942 : ≥ 2.5 kΩ E944 -Y944 : ≥ 1 kΩ E943: RΩ ≤ (Usupply-11)/0.02 E943: RΩ ≤ (Usupply-8)/0.02 (low voltage option) E946: RΩ ≤ (Usupply-6)/0.02

CE -conformity Standards EN50082-1 and -2 (immunity) Standards EN50081-1 and -2 (emissions : a factor of 100 below the permitted maximum) with screened cable, screen connected at both ends Pressure standards 97/23/CE

Global error (linearity, hysteresis and repeatability) by reference to BFSL Typ.: ±0.2% F.S. / Max.: ±0.3% F.S.

Operating temperature Standard E940 - 25...+85°C Standard Y940 - 25...+40°C (T6 approval) - 25...+70°C (T5 approval)

Storage temperature - 40...+85°C

Compensated temperature range (zero and sensitivity) - 10...+55°C. Option : - 10...+70°C

Zero thermal drift ±0.025% FS/°C max (except P 10 mH2O: ±0.06% FS/°C) Option ±0.015 % FS/°C max (except P ≤ 10 mH2O: ±0.025% FS/°C)

Span thermal drift Typically ±0.01%/°C - Max : ±0.015%/°C

Wetted parts Ceramic + stainless steel 1.4404 (316 L) + NBR seal (standard) + cable (polyurethane) Option seal viton® and insuladed cable in ETFE

Standard connections Electrical vented watertight cable Hydraulic G 1/2 for Ø41 (P < 10 mH2O) G 1/4 for Ø23 (P ≥ 10 mH2O) Option protective cap

Protection rating IP68 (Depth = 160 m)(EN 60529)

Vibration resistance 1.5 mm (10 - 55 Hz), 20 g (55 Hz - 2 kHz)(EN 60068-2-6)

Shock resistance 25 falls from 1 m on concrete ground (EN 60028-2-32)

E940 Submersible level transmitter

Technical Data (20°C)

Uncoded Options (have to be listed after the code)

E940, low pressure version (P<10 mH2O)

protection cap (option)The submersible level transmitters E940/Y940 are engineered for a wide variety of industrial and municipal liquid level measurement applications requiring watertight protection.

Page 51: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.06

Ø 27

106

G1/2

Ø 41,1

10G1/4

7610

Ø 23

P 10 mH2O P < 10 mH2OCâble Ø 6.5Lo

ngue

ur d

u câ

ble

kg

0.500

kg

0.180

A

Ø B

A B

P ≥ 10 mH2O 25 22 P < 10 mH2O 25 26,7

Dimensions (mm)

Measuring Ranges (mH2O)

Ordering Details - E940

Model 1´...3´ digitStandard Intrinsically safe Output signal 4´ digit

0...10 Vdc4...20 mA1...5 Vdc0...20 mA

Cable length 5´...7´ digit

Measurement unit 8´ digit

mH2Obarkg/cm2

Pressure range 9´...10´ digit

See codes in tables

x94x xx x xxx

E94Y94 2 3 4 6

J B F

xx

Pressure 0 + 2.5 0 + 4 0 + 6 0 + 10 0 + 16 0 + 25 0 + 40 0 + 60 0 + 100 0 + 160 Max. over pressure 10 10 10 30 30 40 80 120 200 320 Burst pressure 20 20 20 60 60 70 120 180 300 480

Pressure ranges mH2O bar, kg/cm2 Code

10 0 + 2.5 0 + 0.25 11 0 + 4 0 + 0.4 12 0 + 6 0 + 0.6 15 0 + 10 0 + 1 16 0 + 16 0 + 1.6 18 0 + 25 0 + 2.5 19 0 + 40 0 + 4 20 0 + 60 0 + 6 22 0 + 100 0 + 10 24 0 + 160 0 + 16

Length 2 m 3 m 4 m 5 m 6 m 10m 15m 16m 20m 25m 40m 60m 100m 160m others

code 002 003 004 005 006 010 015 016 020 025 040 060 100 160 xxx

Electrical connections

White Blue Screen Red Yellow

4-20 mA + supply - supply ground — —

1-5 V / 0-10 V / 0-20 mA — - supply/- meas. ground + supply + meas.

Protective cap (optional)

Cleat (optional)

Breaking load : 100 daN

UK/

2002

-10

Thi

s da

ta s

heet

may

onl

y be

repr

oduc

ed in

full

Page 52: A1 Electronic Pressure

Specifications (20°C)

With built-in chemical seal top housing, these pressure transmitters (stainless steel body and chemical seal) available in two sizes (equivalent to D100 and D200) provide pressure measurement from 0 + 0.6 bar R/A to 0 + 160 bar R/A and from -1 + 0 bar R to -1 + 39 bar R. The built-in housing also gives the standard model the same measuring specifications as the E910. The welded diaphragm, made of stainless steel 1.4404 (AISI 316 L) on standard model, can be produced in hastalloy, tantalum, PTFE coating, etc. to make it compatible with most industrial fluids.The transmitters are delivered with a coupling and bolts for mounting on a variety of mechanical fixtures. They can also be delivered fitted on process mechanical mounts derived from the D101/D201/D411/D420/D611/D621 range (bottom housings, clamps) to form assemblies ready to mount on the process.

• Built-in industrial chemical seal derived from the D100/D200 family

• Very many mechanical interfacing possibilities• Full pressure range achieved with only one chemical seal

size• Various materials possible for the wetted parts• Intrinsically safe version (Y970), electrical parameters (see

Y910)

• Conforms to European EMC Directive, CE marked

11/0

2 -

A11

.08

UK

Pressure transmitters

Standard E970Intrinsically safe Y970

Measurement range: 0 ... 1 to 0 ... 160 bar

D100E, D101E, D111E -1 ... 1.5 to -1 ... 39 bar

0 ... 0.6 to 0 ... 40 bar D200E, D201E, D211E -1 ... 1.5 to -1 ... 39 bar

0 ... 1 to 0 ... 160 bar D411E, D421E -1 ... 3 to -1 ... 24 bar

0 ... 1 to 0 ... 160 bar D611E, D621E -1 ... 0 to -1 ... 24 bar

Output signal: E972 - Y972 : 0 - 10 Vdc E973 - Y973 : 4 - 20 mA (except - 1 + 0 bar where - 1 = 20 mA, 0 = 4 mA) E974 - Y974 : 1 - 5 Vdc E976 - Y976 : 0 - 20 mA

Supply voltage: E972 : 14 to 40 Vdc Y972 : 14 to 28 Vdc E973 - E974 : 11 to 40 Vdc Y973 - Y974 : 11 to 28 Vdc E976 : 8 to 40 Vdc Y976 : 8 to 28 Vdc Option: high voltage: up to 48 Vdc low voltage: 8 - 32 Vdc (E973, E974) For Y970 intrinsically safe versions, the electrical parameters of the associated equipment are: Ualim ≤ 28 Vdc ; I ≤ 120 mA ; P ≤ 0.8 W (see Y910)

Insulation: >100 MΩ at 250 Vdc. Option: 500 Vdc

Maximum input current: E972 - Y972 / E974 - Y974 : 6 mA E976 - Y976 : < 25 mA

Load impedance (+M /–M): E972 - Y972 : ≥ 2.5 k Ω E974 -Y974 : ≥ 1 k Ω E973: RΩ ≤ (Usupply-11)/0.02 E973: RΩ ≤ (Usupply-8)/0.02 (low voltage option) E976: RΩ ≤ (Usupply-6)/0.02

Electromagnetic compatibility: • Standards EN50082-1 and -2 (immunity) • Standards EN50081-1 and -2 (emission) with shielded cable, shield connected at both ends.

Global error (linearity, hysteresis and repeatability) by reference to BFSL: Typically: ±0.2% of F.S. /

Max.: ±0.3% of F.S.

Operating temperature: • Ambiente (Ta): Standard E970: - 25 to + 85°C Option E970 : Low T °: - 40 to + 85°C / High T °: - 25°C to 100°C Standard Y970: - 25 to + 40°C for T6 approval - 25 to + 70°C for T5 approval • Fluid: Version E970: -25 to + 100°C standard (other on request) Version Y970: according to T6 or T5

Storage temperature: - 40°C to + 85°C

Compensated temperature range (zero and sensitivity): Standard: - 10 to + 55°C. Option: - 10 to + 70°C

Zero thermal drift: ±0,025% EM/°C Max.(except P ≤ 1 bar: ±0.06% F.S./°C) Span thermal drift: Typically: ±0.01%/°C - Max.: ±0.015%/°C

Wetted parts: Flush diaphragm stainless steel 1.4404 (316L) (standard)

Standard electrical and hydraulic connections: See following pages Transmitting fluid: LRS1 : -15 … 150°C (standard)

Protection rating (EN 60529): Standard: IP65 (DIN connector) Option: IP67 or IP68 (depending on connection)

Typical response time: ≤ 3 ms

Vibration resistance (EN 60068-2-6): 1.5 mm (10 - 55 Hz), 20 g (55 Hz - 2 kHz)

Shock resistance (EN 60028-2-32): 25 falls from 1 m on concrete ground.

Modifications reserved.

Page 53: A1 Electronic Pressure

Dimensions (mm), connections

Ø6 ... Ø8 Ø6 ... Ø8

D

Ø6 ... Ø8

a a a a a

a

a

a

a

28

Ø 41.1

a=98

Ø 27Ø 27

a=68

S

Z

D100E, D200E D101E, D201E D111E, D211E D411E, D421E D611E, D621E

Electrical connections

Transmitter body

Hydraulic connections

DIN 43650 connector (standard)

+A +M -A -A / -M +A Ground

White +A Blue -A -A / -M Red +A Yellow +M Braid

Access for adjustment

Type A:

standardP ≥ 1 bar

Option 08DIN 43650C micro plug

(8 mm)

Option 54Pig tail (1.5 m) with 1/2 NPT

Option 23Pig tail (length 1.5 m)

+ PG7 cable gland

Option 22Crimped pig tail (length 1.5 m)

Option 20Terminal strip outlet + screwed cap

Page 54: A1 Electronic Pressure

Ø6 ... Ø8 Ø6 ... Ø8

D

Ø6 ... Ø8

a a a a a

a

a

a

a

28

Ø 41.1

a=98

Ø 27Ø 27

a=68

S

Z

D100E, D200E D101E, D201E D111E, D211E D411E, D421E D611E, D621E

+A +M -A -A/-M +A Ground

White +A +M Blue -A -A / -M Red +A Braid

+A +A +M Ground -A -A / -M

+A +A -A/-M -A +M Ground

Type B:

P < 1 barBody transmitter dimension according to the electrical

connection (a in mm)

Dimension a (mm) Type A Type B

DIN 43650 connector 68 98 Micro DIN 43650C connector 68 98 Pig tail 72.5 102.5 Pig tail + PG7 cable gland 72.5 102.5 Pig tail cable outlet with 1/2 NPT 72 102 Terminal strip outlet + screwed cap 107 137 6 contacts HE302 plug 77.5 107.5 M12, 4 contacts plug 71 101 Submersible cable, IP68(1) 75.5 105.5

(1) no access to adjustments

Option 20Terminal strip outlet + screwed cap

Option 096 contacts HE302 plug

Option 27Submersible cable (IP68)

Option 24M12 4 contacts plug base

Page 55: A1 Electronic Pressure

Measuring ranges

Ordering details

Mod

ifica

tion

s re

serv

ed.

Options

9 7 *TRANSMITTER Model: Standard E Intrinsically safe Y Type: 97 Output signal: 0-10 Vdc 2 4-20 mA 3 1-5 Vdc 4 0-20 mA 6

CHEMICAL SEAL Type: D100E D100E D101E D101E D111E D111E D200E D200E D201E D201E D211E D211E D411E D411E D421E D421E D611E D611E D621E D621E Top housing material: Stainless steel 1.4404 (316L) (standard): SS Others: UR - NI - HB - HC - TA - MO Diaphragm material: Stainless steel 1.4404 (316L) (standard): SS Others: Uranus B6 (UR) - Nickel (NI) - Hastelloy B (HB) - Hastelloy C276 (HC) - Tantalum (TA) - Monel 400 (MO) Transmitting fluid: LRS1 (-15 ... 150°C) (standard): 1 LRS2 (-60 ... 150°C): 2 - LRS3 (-30 ... 30°C): 3 - LRS4 (-15 ... 150°C, oxygen): 4 Bottom housing material (D101E, D111E, D201E, D211E only): Stainless steel 1.4404 (316L) (standard): SS Others: UR - NI - HB - HC - TA - MO Bottom housing connection (D101E, D111E, D201E, D211E only): Male thread: G 1/2 (M001) - 1/2 NPT (M003) - G 3/8 (M004) - G 1/4 (M007) - other threads (M000) Female thread: G 1/2 (F001) - 1/2 NPT (F012) - other threads (F000)

Pressure in bar

Compound pressure — -1+0 -1+0.6 -1+1.5 -1+3 -1+5 -1+9 -1+15 -1+24 -1+39 — — —

Pressure 0.6 1 1.6 2.5 4 6 10 16 25 40 60 100 160

Measurement range 0.7 1.1 1.75 2.75 4.4 6.6 11 17.6 27.5 44 66 110 176

Maximum overpressure 1 3 3 4 8 12 20 32 50 80 120 200 320

Burst pressure 2 6 6 7 12 18 30 48 75 120 180 300 480

Uncoded options have to be listed after the code*

Chemical seal definition

Uncoded Options (have to be listed after the code)DegreasedLightning protectionMarine versionSupply voltage (high/low)(1)

Ambient temperature (high/low)(1)

Compensated temperature range (- 10...+70°C)Span adjustment ±10% of rangeSpan adjustment ±50% of range Calibration of sensor with certificate: Q1060Other electrical connectionsAdditional length of cableOther units: kPa (code D), MPa (code E), kg/cm² (code F), psi (code H), mbar (code N)

Coded Options

Other electrical connections: 08.DIN 43650C micro plug (IP65 (2)) 22.Pig tail (1.5 m) (IP65) 23.Pig tail (1.5 m) + PG7 cable gland (IP65, IP67 (3)) 54.Pig tail cable outlet with 1/2 NPT male (1.5 m) (IP65) 20.Terminal strip outlet + screwed cap (IP65, IP67) 09.6 contacts HE302 plug (IP65) 24.M12, 4 contacts plug (IP65) 27.Submersible cable (IP68 version (4))

(1) see specifications for details / (2) IP65 : water spray / (3) IP67 : temporary immersion /(4) IP68 : prolonged immersion

Page 56: A1 Electronic Pressure

Design and specifications subject to change without noticeData sheet A11.09

Compound and gauge pressure measurement

All stainless steel pressure gauge

Ceramic sensor, TRANSBAR® technology

Zero and span adjustments as standard (±10% of range)

Voltage surge and reverse polarity protection

Intrinsically safe version (Y8900)EEx ia IIc T6 (or T5) approval

Conforms to European EMC directive, CE marked

Technical Data (20°C)

E8900 Pressure gauge with transmitter

Measurement range Compound pressure: -1...0 to -1...24 bar Gauge pressure: 0...1 to 0...400 bar

Output signal E89X2-Y89X2: 0...10 Vdc. E89X3-Y89X3: 4...20 mA (except -1...0 bar or -1 = 20 mA, 0 = 4 mA)

E89X4-Y89X4: 1...5 Vdc. E89X6-Y89X6: 0...20 mA

Supply voltage E89X2: 14...40 Vdc. Y89X2: 14...28 Vdc E89X3-E89X4: 11...40 Vdc.

Y89X3-Y89X4: 11...28 Vdc E89X6: 8...40 Vdc. Y89X6: 8...28 Vdc Option High voltage : up to 48 Vdc Low voltage: 8...32 Vdc (E89X3, E89X4) For intrinsically safe versions Y8900, power supply

electrical parameters device must be : Usupply ≤ 28 Vdc ; I ≤ 120 mA ; P ≤ 0.8 W

Insulation > 100 MΩ at 250 Vdc. Option: 500 Vdc.

Maximum input current E89X2-Y89X2 / E89X4-Y89X4: 6 mA E89X6-Y89X6: < 25 mA

Load impedance (+M / –M) E89X2-Y89X2: ≥ 2.5 k Ω E89X4-Y89X4: ≥ 1 k Ω E89X3: RΩ ≤ (Usupply-11)/0.02 E89X3: RΩ ≤ (Usupply-8)/0.02 (low voltage option ) E89X6: RΩ ≤ (Usupply-6)/0.02

CE -conformity Standards EN50082-1 and -2 (immunity) Standards EN50081-1 et -2 (emission: a factor of

100 below the permitted maximum) with sreened cable, screen connected ar both ends

Pressure standards 97/23/CE

Pressure gauge accuracy Ø 63 mm (E8930) : ±1.6 % of full scale(EN 837-1) Ø 100, 150 and 160 mm (E8950, E8970, E8980) :

±1% of full scale

Global error (linearity, hysteresis and repeatability) by reference to BFSL Typically: ±0.2% of F.S. / Max.: ±0,3%F.S.

Operating temperature Ambient (Ta) Standard E910 -25...+85°C Option E910 Low T°: -40...+85°C. High T°: -25...+100°C Standard Y910 -25...+40°C (T6 approval) -25...+70°C (T5 approval) Fluid -25...+100°C (Ta ≤ 50°C)

Storage temperature -40...+85°C

Compensated temperature range (zero and sensitivity) -10...+55°C. Option: -10...+70°C

Thermal drift (transmitter)

Zero ±0.025% FS/°C max. Option: ±0.015% FS/°C Sensibility ±0.015% FS/°C max.

Case Stainless steel 1.4301 (304)

Wetted parts Ceramic + stainless steel 1.4404 (316 L) + NBR seal

Connections Electrical: DIN 43650 connector (standard) Pressure: G1/2 (standard)

Protection rating (EN 60529) Standard: IP65

Vibration resistance (IEC 68-2-6) BH version: 2.5 mm (5 - 20 Hz) / 5 g (20 to 1000 kHz)

The E8900 is created by the use of a stainless steel pressure gauge – Ø63, 100, 150 or 160 mm – and the E910* pressure transmitter.

It has been designed for all industrial applications to allow both a local pressure reading and remote signal transmission to a Programmable Logic Controller or other computer-based system.

* See leaflet: A11.03.UK

Page 57: A1 Electronic Pressure

Design and specifications subject to change without noticeData sheet A11.09

Design and specifications subject to change without noticeData sheet A11.09www.bourdon-haenni.com

Page 3

Access to adjustments

E8930 - pressure gauge Ø 63 mmMicro DIN 43650C connector as standard

TYPE D

= 0.380kg

Dimensions (mm), weight

TYPE D

= 0.900kg

TYPE F

E8950 - pressure gauge Ø 100 mmDIN 43650 connector as standard

= 0.900kg

A=

110

G1/2

91

Ø6...835

79

Ø101

A=

109

50.5

35 Ø6...8

9319

31.5

Ø101

Electrical connection A

DIN 43650 connector 110

DIN 43650C micro plug (option 08) 108

Pig tail + PG7 cable gland (option 23) 101

Terminal strip outlet +screwed cap (option 20) 121

Electrical connection A

DIN 43650 connector 109

DIN 43650C micro plug (option 08) 107

Pig tail + PG7 cable gland (option 23) 100

Terminal strip outlet + screwed cap (option 20) 120

Page 58: A1 Electronic Pressure

Design and specifications subject to change without noticeData sheet A11.09www.bourdon-haenni.com

Page 2 Design and specifications subject to change without noticeData sheet A11.09

A=

110

G1/2

B=

100

D= 95

35

C= Ø150

Ø6...8

TYPE D

= 1.200kg

TYPE F

E8970 - pressure gauge Ø 150 mmDIN 43650 connector as standard

= 1.200kg

Electrical connection A

DIN 43650 connector 110

DIN 43650C micro plug (option 08) 108

Pig tail + PG7 cable gland (option 23) 101

Terminal strip outlet +screwed cap (option 20) 121

E8980 - pressure gauge Ø 160 mmDIN 43650 connector as standard

A=

109

C= Ø150

B= 97.5

19

35 Ø6...8

31.5

A = 110B = 105C = Ø 160D = 95

A = 109B = 97,5C = Ø 160

TYPE D TYPE F

= 1.300kg

= 1.300kg

Dimensions (mm), weight

Electrical connection A

DIN 43650 connector 109

DIN 43650C micro plug (option 08) 107

Pig tail + PG7 cable gland (option 23) 100

Terminal strip outlet + screwed cap (option 20) 120

Connections

E/Y89X3 E/Y89X2/4/6

1 +Supply + Meas.

2 - Supply - Meas./-Supply

3 + Supply

Ground Ground

Connector DIN and Micro DIN

E/Y89X3 E/Y89X2/4/6

White +Supply

Blue - Supply - Meas./-Supply

Red +Supply

Yellow + Meas

Screen

Cable outlet + cable gland PG7

Page 59: A1 Electronic Pressure

Design and specifications subject to change without noticeData sheet A11.09

Range

* pressure gauge

Compound pressure -1+0 -1+0.6 -1+1.5 -1+3 -1+5 -1+9 -1+15 -1+24 - - - - - -

Pressure 1 1.6 2.5 4 6 10 16 25 40 60 100 160 250 400

Max. over pressure* 1.3 3 4 8 12 20 32 50 80 120 200 320 500 600

Options

Model 1´...3´ digitStandard Intrinsically safe

Dial diameter 4´ digitØ 63Ø 100Ø 150Ø 160

Output signal 5´ digit0...10 Vdc4...20 mA standard1...5 Vdc0...20 mA

Type of mounting 6´ digitBottom connection (Ø 63 - 100 - 150 - 160 mm)Back connection (Ø 100 - 150 - 160 mm)

Hydraulic connection 7´...8´ digitG 1/4 (standard Ø 63 mm)G 1/2 (standard Ø 100 - 150 - 160 mm)1/4 NPT1/2 NPT

Cell O'Ring 9´ digitNBR (nitril) standard

Type of liquid filling 10´ digitDryBH1 filling (-20...+70°C)BH3 filling (-25...+85°C)

Pressure range 11´...13´ digitSee codes in tables

x89xx xxxxx xxx

E89Y89

3 5 7 8

2 3 4 6

D F

02 03 05 06

3

0 1 3

xxx

Measuring Ranges (bar)

Ordering Details - E8900

B59B72B74B76B77B79B81B82B15B16B18B19B20B22B24B26B27B29B31B33B35B38

code

-1 + 0 x x x x-1 + 0.6 x x x x-1 + 1.5 x x x x-1 + 3 x x x x-1 + 5 x x x x-1 + 9 x x x x-1 + 15 x x x x-1 + 24 x x x x 0 + 1 x x x x 0 + 1.6 x x x x 0 + 2.5 x x x x 0 + 4 x x x x 0 + 6 x x x x 0 + 10 x x x x 0 + 16 x x x x 0 + 25 x x x x 0 + 40 x x x x 0 + 60 x x x x 0 + 100 x x x x 0 + 160 x x x x 0 + 250 x x x x 0 + 400 x x x x

Range in Bar Ø du manomètre 63 100 150 160

Uncoded Options (have to be listed after the code) Coded Options

Lightning protectionSupply voltage (high/low)(1)

Ambient temperature (high/low)(1)

Compensated temperature range (- 10...+70°C)Zero thermal drift: ±0.015% of range/°C max.Calibration of sensor with certificate: Q1060B type of mounting (back connection + flange) for Ø100, 150 and 160 mmOther units: kPa (code D), MPa (code E), kg/cm² (code F), psi (code H), mbar (code N) Mounting on chemical seals : please call usOther : please call us

Other electrical connections: 08. DIN 43650C micro plug (IP65 (2)) 23. Pig tail (1.5 m) + PG7 cable gland (IP65, IP67 (3)) 20. Terminal strip outlet + screwed cap (IP65, IP67)

(1) see specifications for details / (2) IP65: water spray / (3) IP67: temporary immersion

UK/

2002

-10

Thi

s da

ta s

heet

may

onl

y be

repr

oduc

ed in

full

Page 60: A1 Electronic Pressure

D6.146 E / 1.01Design and specifications subject to change without notice

Compact Pressure Transmitter ED 505

Application Measurement of gauge pressure of gases and liquids for machinery in heating, air conditioning and sanitary applicationscertified for marine applications (Bureau VeritasType approval)

Construction Compact and rugged execution in stainless steel

Pressure range 1 bar … 400 bar

Output signal 4 … 20 mA

Static error band 0,5% FS typ. (VDI/VDE 2184)

Electrical connection Plug, cable (cable socket, see D6.911 D)

Pressure connection Male thread G1⁄2, G1⁄4, DIN 16288Male thread G1⁄2 DIN 3852 and others

Type of protection IP 65

EMC Protected for industrial environments, according to EN-50081-1 and EN 50082-2

1) Only ≤ 25 bar abs2) Other O-ring seal on request, see D6.901 D, for medium temperature <–20˚C, select EPDM ring.

Accessories see D6.911 D

Electrical connection (Pin assignments and cable colours see D0.320 D)

IA = 4 ... 20 mA

Ordering example: ED 505 / 3 1 4 . 2 1 1 / 075

System design ED 505Pressure type Gauge pressure 3

Absolute pressure1) 4Static error band 0,5% FS max. (Tmed = 25˚C) 1Electrical connect. Cable 2 m 1

Plug DIN 43650 4Output signal IA = 4 … 20 mA 2Pressure connect. Male thread G1⁄2 DIN 16288, stainless steel 1.4305 1

Male thread G1⁄4 DIN 16288, stainless steel 1.4305 2Male thread M20x1,5 DIN 16288, stainless steel 1.4305 3Male thread G1⁄2 DIN 3852, stainless steel 1.4305 4Male thread 1⁄2"-14 NPT, stainless steel 1.4305 6Male thread G1⁄4 DIN 3852, stainless steel 1.4305 7Female thread G1⁄4, stainless steel 1.4305 8Male thread 7/16–20 UNF, stainless steel 1.4305 AMale thread 1⁄4" NPT, stainless steel 1.4305 B

Diaphragm(parts in contact Diaphragm ceramicwith medium) O-ring seal FPM (Viton)2) 1Pressure range

Order Pressurecode range

bar

025 0 … 1

035 0 … 1,6

A15 0 … 2

045 0 … 2,5

055 0 … 4

A25 0 … 5

065 0 … 6

075 0 … 10

085 0 … 16

A35 0 … 20

095 0 … 25

105 0 … 40

A45 0 … 50

Order Pressurecode range

bar

125 0 … 100

135 0 ... 160

A55 0 … 200

145 0 ... 250

155 0 … 400

H05 -1 … 1

515 -1 … -1,5

F05 -1 … 2

525 -1 … 3

535 -1 … 5

545 -1 … 9

315 -1 … 0

Selection Chart

S._15-20_Kat.Elekt.E 17.01.2001 14:04 Uhr Seite 15

Page 61: A1 Electronic Pressure

D6.146 E / 1.01Design and specifications subject to change without notice

Compact Pressure Transmitter ED 505

Construction and FunctionThe pressure transmitter ED 505 Compact has been designedto be used in general purpose application for pressure range of1 to 400 bar. It is also possible to shift the zero point into thevacuum (e.g. to –1 bar). Special efforts were made to the con-struction to allow use under harsh conditions.

The transmitter consists of a stainless steel housing into whicha ceramic pressure sensor, the electronics and the electricalconnection is built in. For standard industrial EMC environ-ments, the connection DIN 43650 is sufficient; however, for verytough conditions, we recommend to use the version with adirect cable.

Pressure range p = 0 … +P bar 1 … 400p = -1 … +P bar -1 … 9

Maximum static pressure bar 1,5 x pressure rangeBurst pressure bar 2 x pressure rangeDeviation of characteristic curve (DIN 16086) ± % FS < 0,5 typ(Tamb = 25° C)Hysteresis and reproducibility ± % FS < 0,1TC zero point (0 …50° C) ± % FS/10 K < 0,4 typTC sensitivity (0 …50° C) ± % FS/10 K < 0,25 typResponse time (10 … 90%) ms ≤ 1Operating temp. (medium) °C -50 … 801)

Housing temperature °C -15 … 801)

Storage temperature °C -40 … 801)

Supply voltage UB 4 … 20 mA V DC 10 … 30Reverse polarity protection for supply UB yesShort circuit proof output yesOvervoltage protection yesLoad (RL+RLine) at 4 … 20 mA Ohm < 1000 (see diagram D0.320 D)Type of protection (DIN 40 050, IEC 144) according selection chartEMC emission (EN 50 081 –1) fulfilledEMC immunity (EN 50 082 –2) fulfilled

IEC 1000–4–2 / EN 61000–4–2 level 3 (8 kV) fulfilledIEC 1000–4–3 / ENV 50140 level 3 (10 V/m) fulfilledIEC 1000–4–4 / EN 61000–4–4 level 4 (4 kV) fulfilledIEC 1000–4–6 / ENV 50141 level (10 V) fulfilled

Vibration test DIN IEC 68 fulfilledTest of load cycles cycles > 1 millionWeight kg ca. 0,2

Technical Data

1) At p abs max. 70°C

Pressure port d l1 l2

G1⁄2 DIN 16288G1⁄4 DIN 16288

M20x1.5 DIN 16288G1⁄2 ’’ DIN 3852

1⁄2 ’’- 14NPTG1⁄4 ’’ DIN 3852G1⁄4 ’’ Female7/16’’-20UNF

1⁄4’’-NPT

656––––––

201320142212

17.513.513

535––––––

Cable

G1⁄4 DIN 16288DIN 43650

G1⁄4 DIN 3852

G ⁄4’’ Female

M20x1.5 DIN 16288

G 1⁄2

l 2l 1

49

SW 27

d

G1⁄2’’ DIN 3852

7⁄16’’-20UNF

1⁄2’’14NPT

1⁄4’’ NPT

S._15-20_Kat.Elekt.E 17.01.2001 14:04 Uhr Seite 16

Page 62: A1 Electronic Pressure

D6.150.1 E / 1.01Design and specifications subject to change without notice

Ordering example: ED 510 / 3 1 4 . 2 1 1 / 155

System design EDX 510EEx ia II C (ATEX)3) EDX 510

Pressure type Gauge pressure 3Absolute pressure 4

Static error band 0,4% FS (Tmed = 25˚C), comp. temp. range -00 … 50°C 1(Tamb = 25˚C) 0,2% FS (Tmed = 25˚C), comp. temp. range -10 … 50°C 2

0,4% FS (Tmed = 25˚C), comp. temp. range -10 … 80°C 40,2% FS (Tmed = 25˚C), comp. temp. range -10 … 80°C 50,4% FS (Tmed = 75˚C), comp. temp. range -50 …100°C 70,4% FS (Tmed = 100˚C), comp. temp. range -75 …125°C 8

Electrical connect. Cable 2 m IP 65 1Plug Fischer1) IP 67 2Plug DIN 41 524 (Binder) IP 65 3Plug DIN 43 650 IP 65 4Cable 2 m IP 67 9

Output signal IA = 0 … 20 mA 1IA = 4 … 20 mA 2UA = 0 … 10 V DC 4UA = 0 … 5 V DC 5

Pressure connect. Male thread G1⁄2 DIN 16 288, stainless steel 1.4435 1Male thread G1⁄4 DIN 16 288, stainless steel 1.4435 2Male thread M20 × 1,5 DIN 16 288, stainless steel 1.4435 3Male thread G1⁄2 DIN 3852 (virtually flush diaphragm), st. steel 1.4435 4Male thread G1⁄8 DIN 16 288 stainless steel 1.4435 5Male thread 1⁄2" NPT (virtually flush diaphragm), stainless steel 1.4435 6Female thread G1⁄4 DIN 3852, stainless steel 1.4435 7Female thread NPT 1⁄4 –18, stainless steel 1.4435 8

Diaphragm Stainless steel 1.4404/316 L 1Hastelloy C-276 2Stainless steel, gold plated2) 9

Pressure range also other pressure ranges and versions in Pa, psi, H2O etc. available

Order Pressurecode range

mbar126 0 … 100136 0 … 160A56 0 … 200

146 0 … 250156 0 … 400A66 0 … 500166 0 … 600

bar025 0 … 1035 0 … 1,6A15 0 … 2

045 0 … 2,5055 0 … 4A25 0 … 5065 0 … 6

075 0 … 10085 0 … 16A35 0 … 20

095 0 … 25105 0 … 40A45 0 … 50

115 0 … 60125 0 … 100135 0 … 160

A55 0 … 200145 0 … 250155 0 … 400

Order Pressurecode range

mbarD06 -100 … -100D26 -100 … -200D56 -100 … -500

H66 -100 … -100H76 -200 … -200H86 -500 … -500

barD85 -0 … -1H05 -1 … -1525 -1 … -3

535 -1 … -5545 -1 … -9

Standard Industrial Pressure Transmitter ED 510

Selection Chart

Application Measurement of gauge and absolute pressureof gases and liquids with normal or highermedium temperatures

Construction Rugged industrial execution in stainless steelZero point and span adjustment

Pressure range 100 mbar … 400 bar

Output signal 0 … 20 mA, 4 … 20 mA,0 … 5 V DC, 0 … 10 V DC

Static error band ≤ 0,25% FS typ., ≤ 0,15% FS typ.

Electrical connection Cable or plug

Pressure connection Male thread G1⁄2, G1⁄4, G1⁄8 DIN 16 288Male thread M20 × 1,5 DIN 16 288Male thread G1⁄2 DIN 3852, O-Ring NBRMale thread 1⁄2" NPTFemale thread G1⁄4" DIN 3852Female thread NPT 1⁄4–18

Type of protection IP 65, IP 67

EMC Protected for industrial environments, conforming to EN 50081-2, EN-50081-1 and EN 50082-2

Accessories Test certificate included

1) Cable socket connector included2) Version ED 510/xxx.x4x and ED 510/xxx.x6x only, max. range 20 bar3) Version 4 … 20 mA only

Special Designs see D6.901 E / Accessories see D6.911 E

S._15-20_Kat.Elekt.E 17.01.2001 14:04 Uhr Seite 17

Page 63: A1 Electronic Pressure

D6.150.1 E / 1.01Design and specifications subject to change without notice

Pressure range 1 0 … +P bar

Maximum pressure P max. bar

Pressure range 2 –P … 0/–P … 0 … +P bar

Maximum pressure P max. bar

Deviation of characteristic ED 510/x1, x4, x7 und x8 ± % FS ≤ 0,25 typ./0,4 max. (see diagram D0.320)curve (Tamb = 25°C) ED 510/x2, x5 ± % FS ≤ 0,15 typ./0,2 max. (see diagram D0.320)

Hysteresis and reproducibility ± % FS ≤ 0,2 (p < 0,4 bar) / 0,1 (p ≥ 0,4 bar)

TC zero point pressure range 1 ± % FS/10 K ≤ED 510/x1, x2, x7, x8 pressure range 2 ± % FS/10 K ≤TC zero point pressure range 1 ± % FS/10 K ≤ED 510/x4, x5 pressure range 2 ± % FS/10 K ≤TC sensitivity ± % FS/10 K ≤ 0,25

Operating temp. (medium) °C according selection chart

Housing temperature °C –20 … 80

Storage temperature °C –40 … 80

Supply voltage UB IA = 0 … 20 mA V DC –16 … 30

IA = 4 … 20 mA V DC –10 … 30

UA = 0 … 5 V DC V DC –09 …30

UA = 0 … 10 V DC V DC –14 … 30

Reverse polarity protection for supply voltage UB yes

Short circuit proof output yes

Overvoltage protection yes

Load (RL + RLine) IA = 0 … 20 mA Ohm ≤ 500

IA = 4 … 20 mA Ohm ≤ 1000 (diagram D0.320)

UA = 0 … 5 V DC kOhm ≥ 5

UA = 0 … 10 V DC kOhm ≥ 10

Zero point adjusting range ± % FS 2

Insulation resistance at 750 V DC MOhm ≥ 1,2

Type of protection (DIN 40 050, IEC 144) according selection chart

EMC emission (EN 50 081-1 and -2) fulfilled

EMC immunity (EN 50 082-2) fulfilled

IEC 1000-4-2 / EN 61000-4-2 level 3 (8 kV) fulfilled

IEC 1000-4-3 / ENV 50140 level 3 (10 V/m) fulfilled

IEC 1000-4-4 / EN 61000-4-4 level 4 (4 kV) fulfilled

IEC 1000-4-6 / ENV 50141 level (10 kV) fulfilled

Vibration test DIN IEC 68 fulfilled

Test of load cycles cycles ≥ 10 millions

Weight kg 0,25

1,0

1,0

1,5

1,5

0,6

0,6

1,0

1,0

0,4

0,4

0,6

0,6

0,3

0,3

0,3

0,3

0,3

0,8

0,3

1,0

0,25

0,5

0,3

0,6

0,25

0,3

0,3

0,3

0,25

0,3

0,3

0,3

0,25

0,3

0,25

0,3

0,25

0,25

0,25

0,3

0,25

0,25

0,25

0,3

Standard Industrial Pressure Transmitter ED 510

Technical Data

Construction and FunctionPressure transmitter ED 510 consists of a pressure connection sectionwith welded stainless steel (or Hastelloy) diaphragm and a stainlesssteel case for housing the electronic circuit and the electrical connec-tion. The piezoresistive pressure sensor is mounted right behind thediaphragm. The pressure being measured is transmitted by the externaldiaphragm and the silicon oil filling to the measuring diaphragm of thepiezoresistive silicon sensor. An amplifier converts the pressure sensor’sbridge to the desired signal level. The amplifier space is sealed toprovide optimal shock and vibration resistance.

The transmitters with a pressure connection similar to DIN 16 288 aresealed before the thread with a washer according to DIN 16 258. Thetransmitters with pressure connection similar to DIN 3852 are sealedbehind the thread with an O-ring (no flush-mounted sealing).Access to the adjusting potentiometer is obtained by unscrewingthe closure ring. Both zero point and span can be adjusted with ascrewdriver.

0,1

4

0…–0,1

4

0,16…0,25

4

0…–0,2

4

0,4…0,6

6

0…–0,5

6

1…1,6

10

0…–1

10

2…4

15

–0,1…0,1

4

5…10

30

–0,2…0,2

4

16…25

75

–0,5…0,5

6

40…60

100

–1…1

10

100…160

250

–1…3

15

200…400

600

–1…5

30

–1…9

30

Electrical Connection (Pin assignments and cable colours see D0.320 D)

IA = 4 … 20 mA IA = 0 … 20 mA, UA = 0 … 5 V, UA = 0 … 10 V

S._15-20_Kat.Elekt.E 17.01.2001 14:04 Uhr Seite 18

Page 64: A1 Electronic Pressure

Design and specifications subject to change without notice D6.150.2 E / 1.01Design and specifications subject to change without notice

Standard Industrial Pressure Transmitter ED 510

Thread Washerd1 d2 d3 d4 b t1 t2 I1 I2 I3

+ 0,5 S DIN 16 258

G1⁄4 5 9,5 5,5 6,5 10 14 12 3 2 14 form A

G1⁄2 6 17,5 7,0 13,5 18 24 20 5 3 22 form B

M20 1,5 6 17,5 7,0 14,5 18 24 20 5 3 22 form B

Connection according to DIN 16 288

Male connectorfor flat sealing

Screw hole with thread

Thread countersunk up to outer diameter

Mounted connector

Maleconnector

Screw hole

Washer

I1 100

30,5

I1 104 35

17

18,5 SW 27 SW 2718

100

122 122

58 23 98

Seal

M20

1,

5G

1 ⁄ 2, G

1 ⁄ 4, G

1 ⁄ 8

M20

1,

5G

1 ⁄ 2, G

1 ⁄ 4, G

1 ⁄ 8

G1 ⁄4

’’

1 ⁄ 4’’

NP

T1 ⁄2"

NP

T

DIN 3852 DIN 41 524 NPT Kabel

DIN 3852 DIN 41 524 NPT Cable

Dimensions

DIN 16 288 DIN 43 650 DIN 16 288 Fischer

G1 ⁄2

27 mm Hex.

27 mm Hex.

27 mm Hex. 27 mm Hex.

27 mm Hex.

27 mm Hex.

S._15-20_Kat.Elekt.E 17.01.2001 14:04 Uhr Seite 19

Page 65: A1 Electronic Pressure

D6.153 E / 1.01Design and specifications subject to change without notice

Ordering example: ED 513 / 3 1 4 . 2 1 1 / 155

System design EDX 513EEx ia II C (ATEX)3) EDX 513

Pressure type Gauge pressure 3Absolute pressure 4

Static error band 0,4% FS (Tmed = 25°C), comp. temp. range 0 … 50°C 1(Tamb = 25˚C) 0,2% FS (Tmed = 25°C), comp. temp. range 0 … 50°C 2

0,4% FS by adjusted temperature1) 70,2% FS by adjusted temperature1) 8

Electrical connect. Cable 2 m IP 65 1Plug Fischer2) IP 67 2Plug DIN 41 524 (Binder) IP 65 3Plug DIN 43 650 IP 65 4

Output signal IA = 0 … 20 mA 1IA = 4 … 20 mA 2UA = 0 … 10 V DC 4UA = 0 … 5 V DC 5

Pressure connect. Male thread G1⁄2 DIN 3852, stainless steel 1.4435 1Diaphragm Stainless steel 1,4404/316 L 1

Hastelloy C-276 2Pressure range Also other pressure ranges and versions in Pa, psi, H2O etc. available

Order- Pressurecode range

mbar126 0 … 100136 0 … 160A56 0 … 200

146 0 … 250156 0 … 400A66 0 … 500166 0 … 600

bar025 0 … 1035 0 … 1,6A15 0 … 2045 0 … 2,5055 0 … 4A25 0 … 5065 0 … 6

075 0 … 10085 0 … 16A35 0 … 20

095 0 … 25105 0 … 40A45 0 … 50

115 0 … 60125 0 … 100135 0 … 160

A55 0 … 200145 0 … 250155 0 … 400

Order- Pressurecode range

mbarD06 -100 … -100D26 -100 … -200D56 -100 … -500

H66 -100 … -100H76 -200 … -200H86 -500 … -500

barD85 -0 … -1H05 -1 … -1525 -1 … -3535 -1 … -5545 -1 … -9

Industrial Pressure Transmitter for High Temperature ED 513

Selection Chart

1) Adjusted temperatureIf the adjustment of the medium is above 25°C, the temperature must be advised with the order code /9007/XXXX.Ordering example: adjustment at 150°C, order code /9007/0150.The compensated temperature range is ± 25°C of the adjusted temperature. If the adjusted temperature is above 175°C, the compensated range will always be 150°C to 200°C.2) Cable socket connector included.3) Version 4 ... 20 mA only

Special Designs see D6.901 E / Accessories see D6.911 E

Application Measurement of absolute and relative pressure of gases and liquids for temperatures up to 200°C

Construction Rugged industrial version in stainless steel.Zero point and sensitivity adjustable

Pressure range 100 mbar … 400 bar

Output signal 0 … 20 mA, 4 … 20 mA,0 … 5 V DC, 0 … 10 V DC

Medium temperature –40 … 200°C

Static error band ≤ 0,25% FS typ., ≤ 0,15% FS typ.

Electrical connection Plug or cable

Pressure connection Male thread G1⁄2 DIN 3852O-Ring-/Silcoflon PFA, Nitril NBR, Viton FPM

Type of protection IP 65, IP 67

EMC Protected for industrial environments, conforming to EN 50081-2, EN 50081-1and EN 50082-2

Accessories Test certificate

Electrical Connection (Pin assignments and cable colours see D0.320 E)IA = 4 … 20 mA IA = 0 … 20 mA, UA = 0 … 5 V, UA = 0 … 10 V

S._21-24_Kat.Elekt.E 17.01.2001 14:11 Uhr Seite 21

Page 66: A1 Electronic Pressure

D6.153 E / 1.01Design and specifications subject to change without notice

p (bar) L (mm)

0.1 ... ≤ 10 171

<10 ... 400 179

Pressure range 1 0 … +P bar

Maximum Pressure P max. bar

Pressure range 2 –P … 0/–P … 0 … +P bar

Maximum Pressure P max. bar

Deviation of characteristic ED 513/x1 ± % FS ≤ 0,25 typ./0,4 max. (see diagramm D0.320)

curve (Tmed = 25°C) ED 513/x2 ± % FS ≤ 0,15 typ./0,2 max. (see diagramm D0.320)

Hysteresis and reproducibility ± % FS ≤ 0,2 (p < 0,4 bar) / 0,1 (p ≥ 0,4 bar)

TC zero point1) pressure range 1 ± % FS/10 K ≤pressure range 2 ± % FS/10 K ≤

TC sensitivity1) ± % FS/10 K ≤ 0,25

Operating temp. (medium) °C –40 … 200 (see diagram medium pressure)

Housing temperature °C –20 … 80

Storage temperature °C –40 … 80

Supply voltage UB IA = 0 … 20 mA V DC –16 … 30

IA = 4 … 20 mA V DC –10 … 30

UA = 0 … 5 V DC V DC –09 … 30

UA = 0 … 10 V DC V DC –14 … 30

Reverse polarity protection for supply UB yes

Short circuit proof output yes

Overvoltage protection yes

Load (RL + RLine) IA = 0 … 20 mA Ohm ≤ 500

IA = 4 … 20 mA Ohm ≤ 1000 (see diagram D0.320)

UA = 0 … 5 V DC kOhm ≥ 5

UA = 0 … 10 V DC kOhm ≥ 10

Zero point adjusting range ± % FS 2

Insulation resistance at 750 V DC MOhm ≥ 1,2

Type of protection (DIN 40 050, IEC 144) according selection chart

EMC emission (EN 50 081-1 and 2) fulfilled

EMC immunity (EN 50 082-2) fulfilled

IEC 1000-4-2 / EN 61000-4-2 level 3 (8 kV) fulfilled

IEC 1000-4-3 / ENV 50140 level 3 (10 V/m) fulfilled

IEC 1000-4-4 / EN 61000-4-4 level 4 (4 kV) fulfilled

IEC 1000-4-6 / ENV 50141 level (10 kV) fulfilled

Weight kg 0,35

1,8

1,8

1,0

1,0

0,3

1,0

0,3

0,3

0,3

0,3

0,25

1,0

0,25

0,8

0,25

0,5

0,25

0,3

0,25

0,3

0,25

0,3

Industrial Pressure Transmitter for High Temperature ED 513

Technical Data

Construction and Function

Dimensions Ambient Temperature Medium pressureAllowed Ambient Temp. Range Admissible medium pressure as aas a function of medium temp. function of medium temperature

The pressure transmitter ED 513 consists of a pressure connection body pro-vided with cooling radiator and a welded stainless steel or hastelloy dia-phragm and a stainless steel case to house the electronic circuitry and theelectrical connection. The piezoresistive pressure sensor is mounted withinthe body of the transmitter and separated from the diaphragm by the trans-mission/cooling oil.The pressure being measured is transmitted from the diaphragm and thetransmission liquid to the piezoresistive silicon sensor.An amplifier converts the pressure sensor’s bridge signal to the desired level.The amplifier and associated electronics are encapsulated to give an optimalprotection against shock and vibration.

The pressure transmitter is designed with a G1⁄2 pressure connection similarto DIN 3852. The sealing is provided at the thread with an O-ring, speciallydesigned for high temperatures.Electrical connection with plug DIN 43 650 and cable: For the adjustment ofthe zero point and span, the two potentiometers are accessible after unscre-wing the ring under connector. The zero point and span can be adjustedexternaly with a screw-driver.Electrical connection with round plug IP 67: The potentiometers for zero pointand span are accessible from externally.

0,1

4

0…–0,1

4

0,16…0,25

4

0…–0,2

4

0,4…0,6

6

0…–0,5

6

1…1,6

10

0…–1

10

2…4

15

–0,1…0,1

4

5…10

30

–0,2…0,2

4

16…25

75

–0,5…0,5

6

40…60

100

–1…1

10

100…160

250

–1…3

15

200…400

600

–1…5

30

–1…9

30

1) Calibration temperature ±25°C

–0,5 bar

0 bar

p rel

–1 bar

prohibitedzone

Medium pressure

pabs

1 bar

0,5 bar

1 mbar0–50 0 100 200 Medium

temperature °C

Joint

S._21-24_Kat.Elekt.E 17.01.2001 14:11 Uhr Seite 22

Page 67: A1 Electronic Pressure

D6.158.1 E / 1.01Design and specifications subject to change without notice

Ordering example ED 518 / 3 1 4 . 2 9 1 / 075

System design EDX 518EEx ia II C (ATEX)4) EDX 518

Pressure type Gauge pressure 3Absolute pressure 4

Static error band1) 0,4% FS (Tmed = 25˚C), comp. temp. range 0 … 50°C 1(Tamb = 25˚C) 0,2% FS (Tmed = 25˚C), comp. temp. range 0 … 50°C 2Electrical connect. Cable 2 m IP 65 1

Plug Fischer 3) IP 67 2Plug DIN 41 524 (Binder) IP 65 3Plug DIN 43 650 IP 65 4Cable 2 m IP 67 9

Output signal IA = 0 … 20 mA 1IA = 4 … 20 mA 2UA = 0 … 10 V DC 4UA = 0 … 5 V DC 5

Pressure connect. Male thread G1⁄2 DIN 16 288 1Male thread G1⁄4 DIN 16 288 2Connection for separator 2) 9

Pressure connect.material Stainless steel 1.4435 1Pressure range also other pressure ranges and versions in Pa, psi, H2O etc. available

Order Pressurecode range

bar025 0 … 1035 0 … 1,6A15 0 … 2

045 0 … 2,5055 0 … 4A25 0 … 5

065 0 … 6075 0 … 10085 0 … 16A35 0 … 20

095 0 … 25105 0 … 40A45 0 … 50

Order PressureOrder range

bar115 0 … 60125 1 … 100135 0 … 160

A55 0 … 200145 0 … 250155 0 … 400

D85 -0 … -1H05 -1 … -1525 -1 … -3

535 -1 … -5545 -1 … -9

Pressure Transmitter for Assembly with Separator ED 518

Selection Chart

1) without separator 2) Connection will be defined by HAENNI 3) cable socket connector included 4) Version 4 … 20 mA only

Special Designs see D6.901 E / Accessories see D6.911 E

Application Measurement of gauge and absolute pressure for gases and liquids with assembledseparator

Construction Rugged industrial execution in stainless steelZero point and span adjustment

Pressure range 1 … 400 bar

Output signal 0 … 20 mA, 4 … 20 mA,0 … 5 V DC, 0 … 10 V DC

Static error band ≤ 0,25% FS typ., ≤ 0,15% FS typ.

Electrical connection Cable or plug

Pressure connection see catalog sheets of separator

Type of protection IP 65, IP 67

EMC Protected for industrial environments, conforming to EN 50081-2, EN 50081-1 andEN 50082-2

Accessory Test certificate

Electrical Connection (Pin assignments and cable colours see D0.320 E)

IA = 4 … 20 mA IA = 0 … 20 mA, UA = 0 … 5 V, UA = 0 … 10 V

S._25-30_Kat.Elekt.E 17.01.2001 14:17 Uhr Seite 25

Page 68: A1 Electronic Pressure

D6.158.1 E / 1.01Design and specifications subject to change without notice

Pressure range 0 … +P bar

Maximum Pressure P max. bar

Deviation of characteristic ED 518/x1 ± % FS ≤ 0,25 typ./0,4 max. (see diagram D0.320)curve (Tamb = 25°C) ED 518/x2 ± % FS ≤ 0,15 typ./0,2 max. (see diagram D0.320)

Hysteresis and reproducibility ± % FS ≤ 0,1

TC zero point (ED 518 only) ± % FS/10 K ≤TC sensitivity (ED 518 only) ± % FS/10 K ≤ 0,3

Operating temp. (medium) com./not comp. °C 0 … 50

Housing temperature °C –20 … 80

Storage temperature °C –40 … 80

Supply voltage UB IA = 0 … 20 mA V DC –16 … 30

IA = 4 … 20 mA V DC –10 … 30

UA = 0 … 5 V DC V DC –09 … 30

UA = 0 … 10 V DC V DC –14 … 30

Reverse polarity protection for supply UB yes

Short circuit proof output yes

Overvoltage protection yes

Load (RL + RLine) IA = 0 … 20 mA Ohm ≤ 500

IA = 4 … 20 mA Ohm ≤ 1000 (see diagram D0.320)

UA = 0 … 5 V DC kOhm ≥ 5

UA = 0 … 10 V DC kOhm ≥ 10

Zero point adjusting range ± % FS 2

Insulation resistance at 750 V DC MOhm ≥ 1,2

Type of protection (DIN 40 050, IEC 144) IP 65, IP 67

EMC emission (EN 50 081-1 and -2) fulfilled

EMC immunity (EN 50 082-2) fulfilled

IEC 1000-4-2 / EN 61000-4-2 level 3 (8 kV) fulfilled

IEC 1000-4-3 / ENV 50140 level 3 (10 V/m) fulfilled

IEC 1000-4-4 / EN 61000-4-4 level 4 (4 kV) fulfilled

IEC 1000-4-6 / ENV 50141 level (10 kV) fulfilled

Test of load cycles cycles ≥ 10 millions

Weight kg 0,16

0,3

Technical Data

Construction and Function

1…1,6

10

2…4

15

5…10

3016…25

75

40…60

100

100…160

250

200…400

600

0,3 0,3 0,3 0,3 0,3 0,3

Industrial Pressure Transmitter for Assembly with Separator ED 518

The Pressure transmitter ED 518 consists of a pressure connectionsection fix assembled with a separator and a stainless steel case forhousing the electronic circuit. The piezoresistive pressure sensor ismounted in the pressure connection section. The pressure being mea-sured is transmitted by the external diaphragm and the transmissionliquid (normally silicon oil, other liquids for special applications are avai-lable) to the measuring diaphragm of the piezoresistive silicon sensor.An amplifier converts the pressure sensor’s bridge to the desired signal

level. The amplifier space is sealed to provide optimal shock and vibra-tion resistance.The pressure connection of the pressure transmitter is in conformity withthe assembled separator.The ED 518 is provided with 2 potentiometers for the adjustment ofthe zero point and of span. Access to the adjusting potentiometer isobtained by unscrewing the closure ring, or at the IP 67 version theoutside.

Dimensions

Thread L1

G1⁄2 20

G1⁄4 13

Separator dimensionssee catalog «Separators»

I1 100

G1 ⁄4

, G1 ⁄2

30,5

DIN 16 288 DIN 43 650

S._25-30_Kat.Elekt.E 17.01.2001 14:17 Uhr Seite 26

Page 69: A1 Electronic Pressure

D6.158.2 E / 1.01Design and specifications subject to change without notice

Synoptical table of separators

Industrial Pressure Transmitter for Assembly with Separator ED 518

Separator type Ordering code TC separator TC capillary1)

%/10 K %/10 Kat range 1 bar2) at range 1 bar2)

Diaphragm separator series 1020 1020–1022 0,4 0,2Diaphragm separator series 1030 1031–1042 0,3 0,1

1045–1046 on request on requestDiaphragm separator series 1060 1061–1062 2,0 2,6

1063–1064 1,9 2,61065–1066 2,0 2,6

Diaphragm separator series 1080 1081 0,9 0,71085–1086 2,0 2,8

Diaphragm separator series 1090 1091–1092 0,5 0,51093–1094 0,6 0,3

Diaphragm separator series 1100 + 1140 1107 2,0 2,81101 1,7 1,3

1103–1143 0,6 0,31105–1145 0,3 0,2

1109 0,3 0,11111 0,2 0,1

Diaphragm separator series 1470 1475 0,9 0,91476 0,6 0,51477 0,6 0,51471 0,3 0,11487 0,2 0,051473 0,1 0,011479 0,1 0,011481 0,05 0,02

Tongue design separator series 1500 1501–1502 2,1 1,2Tongue design separator series 1510 1511–1514 2,1 1,2Pipe separator series 1530 1531 0,2 0,2

1532 0,7 0,61537 0,7 0,51534 0,3 0,31533 0,1 0,11536 0,2 0,11535 0,1 0,11539 0,2 0,1

Pipe separator series 1540 1547 1,0 2,01541 0,1 0,21545 0,3 0,31542 0,5 0,41543 0,4 0,31544 0,1 0,11546 0,2 0,1

Pipe separator series 1620 1627 1,0 2,01621 0,1 0,21622 0,2 0,21623 0,4 0,31624 0,2 0,11625 0,2 0,11626 0,3 0,1

Pipe separator series 1650 1653 0,3 0,41655 0,2 0,11656 0,1 0,11657 0,3 0,21658 0,2 0,11659 0,2 0,1

Pipe separator series 1660 1663 0,3 0,41665 0,2 0,11666 0,1 0,11667 0,3 0,21668 0,2 0,11669 0,2 0,1

Pipe separator series 1680 1683 0,5 1,91685 0,2 0,21686 0,3 0,31687 0,3 0,31688 0,2 0,21689 0,4 0,4

1) in reference to a capillary of 1 mat ∅ 1 mm. 2) at higher pressure ranges the TC decreases of the range, e.g. at 10 bar of the factor 10.

S._25-30_Kat.Elekt.E 17.01.2001 14:17 Uhr Seite 27

Page 70: A1 Electronic Pressure

D6.160 E / 1.01Design and specifications subject to change without notice

Electrical Connection (Pin assignments and cable colours see D0.320 E)IA = 4 … 20 mA IA = 0 … 20 mA, UA = 0 … 5 V, UA = 0 … 10 V

Ordering example ED 520 / 3 1 4 . 2 1 1 / 025

System design ED 520EEx ib IIC (ATEX)1) EDX 520

Pressure type Gauge pressure 3Absolute pressure 4

Static error band 0,4% FS (Tmed = 25˚C), comp. temp. -00 … 50°C 1(Tamb = 25˚C) 0,2% FS (Tmed = 25˚C), comp. temp. -10 … 50°C 2

0,4% FS (Tmed = 25˚C), comp. temp. -10 … 80°C 40,2% FS (Tmed = 25˚C), comp. temp. -10 … 80°C 50,4% FS (Tmed = 75˚C), comp. temp. -50 …100°C 70,4% FS (Tmed = 100˚C), comp. temp. -75 …125°C 80,4% FS at specified adjusted temp., Tmax=150°C2)3) A0,2% FS at specified adjusted temp., Tmax=150°C2)3) B

Electrical connect. Cable 2 m IP 654) 1Plug Bendix IP 654) 2Plug DIN 41 524 (Binder) IP 654) 3Plug DIN 43 650 IP 654) 4Cable 2 m with relative tube IP 674) 9

Output signal IA = 0 … 20 mA 1IA = 4 … 20 mA 2UA = 0 … 10 V DC 4UA = 0 … 5 V DC 5

Pressure connect. G 1⁄2 with cone (see selection chart) 1G1 with cone (see selection chart) 2Male thread G1⁄2 DIN 16 288 (available for all pressure ranges)5) 4G 1⁄2 without cone (available for all pressure ranges)5) 8G1 without cone (available for all pressure ranges)5) 9

Diaphragm Stainless steel 1.4404/316 L 1Hastelloy C-276 2Stainless steel, gold plated3) 9

Pressure range also other pressure ranges and versions in Pa, psi, H2O etc. available

Order Pressurecode range

mbar126 0 … 100136 0 … 160A56 0 … 200

146 0 … 250156 0 … 400A66 0 … 500166 0 … 600

bar025 0 … 1035 0 … 1,6A15 0 … 2045 0 … 2,5055 0 … 4A25 0 … 5

065 0 … 6075 0 … 10075 0 … 10

085 0 … 16A35 0 … 20095 0 … 24105 0 … 40

Conn.

G1G1G1

G1G1G1G1

G1G1G1G1G1G1

G1G1G1⁄2

G1⁄2G1⁄2G1⁄2G1⁄2

Conn.

G1⁄2G1⁄2G1⁄2

G1⁄2G1⁄2G1⁄2

G1G1G1G1G1G1

G1G1G1

G1G1

Order Pressurecode range

bar115 -100 … 60125 -100 … 100135 -100 … 160

A55 -100 … 200145 -100 … 250155 -100 … 400

mbarD06 -0 … -100D26 -0 … -200A15 -0 … -500H66 -100 … -100H76 -200 … -200H86 -500 … -500

barD85 -0 … -1H05 -1 … -1525 -1 … -3

535 -1 … -5545 -1 … -9

Pressure Transmitter with Flush Diaphragm ED 520

Selection Chart

1) Version 4 … 20 mA only (with IP 42)2) Temperature adjustments

For temperature adjustments (medium) other than 25°C, the temperature has to be indicated by the order code /9007/xxx. Ordering example: adjustment at 125°C, order code /9007/0125. The compensated temperature range is ± 25°C of the adjusted temperature. If the temperature is above 125°C, the range will always be 100°C to 150°C.

3) Not available for ED 520/xxx.x4x. 4) Not available for EEx. 5) Not available for ED 520/x AB x .xxx

Special Designs see D6.901 E / Accessories see D6.911.1 E

Application Measurement of gauge and absolute pressure forgases and liquids (Level gauging, food industry,sterilizers, pharma industry)

Construction Stainless steel 1.4435 flush diaphragm orconnection acc. DIN 16288.Connection with cone flush metallic sealing (for food application). External zero point andspan adjustment

Pressure range 100 mbar … 400 bar

Output signal 0 … 20 mA, 4 … 20 mA,0 … 5 V DC, 0 … 10 V DC

Static error band ≤ 0,25% FS typ., ≤ 0,15% FS typ.

Electrical connection Cable or plugPressure connection Male thread with cone 1⁄2’’ and 1’’

Male thread without cone 1⁄2’’ und 1’’Male thread G1⁄2’’ DIN 16 288

Type of protection IP 65, IP 67EMC Protected for industrial environments, conforming

to EN 50081-2, EN-50081-1 and EN 50082-2

Accessory Test certificate

S._25-30_Kat.Elekt.E 17.01.2001 14:17 Uhr Seite 29

Page 71: A1 Electronic Pressure

D6.160 E / 1.01Design and specifications subject to change without notice

B1 C C C DA B B1 ED 520/xAx.xxx Plug Plug Plug Plug

ED 520/xBx.xxx DIN Bendix Binder DING1⁄2 with cone 23 101 119,5 10 20 12 30,5G1 with cone 27 97 121,5 10 20 12 30,5G1⁄2 without cone 20,5 101 119,5 10 20 12 30,5G1 without cone 20,5 97 121,5 10 20 12 30,5G1⁄2 16 288 20 90 119,5 10 20 12 30,5

Pressure Transmitter with Flush Diaphragm ED 520

Construction and Function

Medium pressure Dimension ChartAdmissible medium pressure as a function of medium temperature

Pressure transmitter ED 520 consists of a pressure connection sectionwith welded stainless steel diaphragm and a stainless steel case forhousing the electronic circuit and the electrical connection. The piezore-sistive pressure sensor is mounted directly behind the diaphragm (exceptfor the types ED 520/xAx and ED 520/xBx). For applications with veryaggressive mediums, the cone and diaphragm are gold plated. The pres-sure being measured is transmitted by the external diaphragm and thesilicon oil filling to the measuring diaphragm of the piezoresistive silicon

sensor. An amplifier converts the pressure sensor’s signal to the desiredsignal level. The G1 and G1⁄2 pressure connector with cone makes metal-lic seals and is suitable for food application. For less critical applicationsthe use of other seals are intended.The zero point and span can be adjusted externally by a screwdriver.

Technical Date

Dimensions

Screw hole with thread chamber for DIN 16 288

Mounting example

ED 520/xAx.xxxED 520/xBx.xxx

–0,5 bar

0 bar

p rel

–1 bar

prohibitedzone

Medium pressure

pabs

1 bar

0,5 bar

1 mbar0–50 0 50 100 200 300 Medium temperature °C

120

Pressure range 1 0 … +P barMaximum Pressure P max. barDeviation of characteristic ED 520/x1, 4, 7 and 8, xA ± % FS ≤ 0,25 typ./0,4 max.(see diagram D0.320)curve (Tamb = 25°C) ED 520/x2 and 5, xB ± % FS ≤ 0,15 typ./0,2 max.(see diagram D0.320)Hysteresis and reproducibility ± % FS ≤ 0,2 (p < 0,4 bar) / 0,1 (p ≥ 0,4 bar)TC zero point ± % FS/10 K ≤TC sensitivity ± % FS/10 K ≤ 0,2Operating temp. (medium) comp./not. comp. °C according selection chartHousing temperature °C –20 … 80Storage temperature °C –40 … 80Supply voltage UB IA = 0 … 20 mA V DC –16 … 30

IA = 4 … 20 mA V DC –10 … 30UA = 0 … 5 V DC V DC –09 …30UA = 0 … 10 V DC V DC –14 … 30

Reverse polarity protection for supply voltage UB yesShort circuit proof output yesOvervoltage protection yesLoad (RL + RLine) IA = 0 … 20 mA Ohm ≤ 500

IA = 4 … 20 mA Ohm ≤ 1000 (see diagram D0.320)UA = 0 … 5 V DC kOhm ≥ 5UA = 0 … 10 V DC kOhm ≥ 10

Zero point adjusting range ± % FS 2Insulation resistance at 750 V DC MOhm ≥ 1,2Type of protection (DIN 40 050, IEC 144) according selection chartEMC emission (EN 50 081-1 und -2) fulfilledEMC immunity (EN 50 082-2) fulfilled

IEC 1000-4-2 / EN 61000-4-2 level 3 (8 kV) fulfilledIEC 1000-4-3 / ENV 50140 level 3 (10 V/m) fulfilledIEC 1000-4-4 / EN 61000-4-4 level 4 (4 kV) fulfilledIEC 1000-4-6 / ENV 50141 level (10 kV) fulfilled

Vibration test DIN IEC 68 fulfilledWeight kg 0,50

0,14

0,16…0,254

0,4…0,66

1…1,610

2…415

5…1030

16…2575

40…60100

100…160250

200…400600

0,20,5 0,35

with cone

plug DIN

plug Bendix

with cone

cable

plug

without cone

male connectorscrew holewasher

S._25-30_Kat.Elekt.E 17.01.2001 14:17 Uhr Seite 30

Page 72: A1 Electronic Pressure

Ordering example: ED 522 / 3 1 1 . 2 1 1 / A15

System design EDX 522EEx ia II C (ATEX)3) EDX 522

Pressure type Gauge pressure 3Absolute pressure 4

Static error 0,4% FS (Tmed = 25˚C), comp. temp. -00 … 50°C 1band (Tmed = 25˚C) 0,2% FS (Tmed = 25˚C), comp. temp. -10 … 50°C 2

0,4% FS (Tmed = 25˚C), comp. temp. -10 … 80°C 40,2% FS (Tmed = 25˚C), comp. temp. -10 … 80°C 50,4% FS (Tmed = 75˚C), comp. temp. -50 …100°C 70,4% FS (Tmed = 100˚C), comp. temp. -75 …125°C 80,4% at specified adjusted temp., Tmax = 150˚C 1) A0,2% at specified adjusted temp., Tmax = 150˚C 1) B

Electrical connect. Cable 2 m IP 65 1Plug Fischer2) IP 67 2Plug DIN 41 524 (Binder) IP 65 3Plug DIN 43 650 IP 65 4

Output signal IA = 0 … 20 mA 1IA = 4 … 20 mA 2UA = 0 … 10 V DC 4UA = 0 … 5 V DC 5

Pressure connect. Clamp ISO 2852, nominal size 22 mm, < 1 bar with TC zero p. corr. 1Clamp ISO 2852, nominal size 38 mm (11⁄2’’) 3Clamp ISO 2852, nominal size 51 mm (2’’) 5Clamp ISO 2852, nominal size 63,5 mm (21⁄2’’) 6

Diaphragm Stainless steel 1.4404/316 L 1Stainless steel, gold plated 9

Pressure range also other pressure ranges and versions in Pa, psi, H2O etc. available

D6.162 E / 1.01Design and specifications subject to change without notice

Selection Chart

1) For temperature adjustments (medium) other than 25°C, the temperature has to be indicated by the order code /9007/XXXX. Ordering example: adjustment at 125°C, order code /9007/0125. The compensated temperature range is ±25°C of the adjusted temperature. If the temperature is above 125°C the range will always be 100°C to 150°C.

2) Cable socket included.3) Version 4 … 20 mA only.

Special Designs see D6.901 E / Accessories see D6.911 E

Electrical Connection (Pin assignments and cable colours see D0.320 E)

IA = 4 … 20 mA IA = 0 … 20 mA, UA = 0 … 5 V, UA = 0 … 10 V

Application Measurement of gauge and absolute pressurefor gases and liquids

Construction Stainless steel 1.4435Flush diaphragmClamp liner with gasket for the food industryISO 2852Zero point and span adjustment

Pressure range 100 mbar … 16 bar

Output signal 0 … 20 mA, 4 … 20 mA,0 … 5 V DC, 0 … 10 V DC

Static error band ≤ 0,25% FS typ., ≤ 0,15% FS typ.

Electrical connection Cable or plug

Pressure connection Clamp connection for quick mounting

Type of protection IP 65, IP 67

EMC Protected for industrial environments, conformingto EN 50081-2, EN-50081-1 and EN 50082-2

Accessory Test certificate

Pressure Transmitter with Flush Diaphragm and Clamp Connection ED 522

Order Pressurecode range

mbar126 0 … 100136 0 … 160A56 0 … 200

146 0 … 250156 0 … 400A66 0 … 500166 0 … 600

bar025 0 … 1035 0 … 1,6A15 0 … 2

045 0 … 2,5055 0 … 4A25 0 … 5065 0 … 6075 0 … 10085 0 … 16

Order Pressurecode range

mbarD06 -100 … -100D26 -100 … -200D56 -100 … -500

H66 -100 … -100H76 -200 … -200H86 -500 … -500

barD85 -0 … -1H05 -1 … -1525 -1 … -3

535 -1 … -5545 -1 … -9

74-00

S._31-36_Kat.Elekt.E 18.01.2001 15:38 Uhr Seite 31

Page 73: A1 Electronic Pressure

D6.162 E / 1.01Design and specifications subject to change without notice

Medium pressureAdmissible medium pressure as a function of medium temperature

Pressure Transmitter with Flush Diaphragm and Clamp Connection ED 522Technical Data

Mountingexample

Accessories Order no.Clamp ring 20 D 12271.0000

11⁄2’’ D 12271.00012’’ D 12271.0002

21⁄2’’ D 12271.0003Gasket NBR/Nitril 20 D 12272.0100

11⁄2’’ D 12272.01012’’ D 12272.0102

21⁄2’’ D 12272.0103Clamp liner welding 1.4404 20 D 12273.0000

11⁄2’’ D 12273.00012’’ D 12273.0002

21⁄2’’ D 12273.0003

Pressure range 1 0 … +P barMaximum Pressure P max. barDeviation of characteristic ED 522/x1,x4, x7, x8, xA ± % FS ≤ 0,25 typ./0,4 max. (see diagram D0.320 D)curve (Tamb = 25°C) ED 522/x2,x5, xB ± % FS ≤ 0,15 typ./0,2 max. (see diagram D0.320 D)Hysteresis and reproducibility ± % FS ≤ 0,2 (p < 0,4 bar) / 0,1 (p ≥ 0,4 bar)TC zero point ± % FS/10 K ≤TC sensitivity ± % FS/10 K ≤ 0,2Operating temp. (medium) compensated °C according selection chartHousing temperature °C –20 … 80Storage temperature °C –40 … 80Supply voltage UB IA = 0 … 20 mA V DC –16 … 30

IA = 4 … 20 mA V DC –10 … 30UA = 0 … 5 V DC V DC –09 …30UA = 0 … 10 V DC V DC –14 … 30

Reverse polarity protection for supply voltage UB yesShort circuit proof output yesOvervoltage protection yesLoad (RL + RLine) IA = 0 … 20 mA Ohm ≤ 500

IA = 4 … 20 mA Ohm ≤ 1000 (see diagram D0.320)UA = 0 … 5 V DC kOhm ≥ 5UA = 0 … 10 V DC kOhm ≥ 10

Zero point adjusting range ± % FS 2Insulation resistance at 750 V DC MOhm ≥ 1,2Type of protection (DIN 40 050, IEC 144) according selection chartEMC emission (EN 50 081-1 and -2) fulfilledEMC immunity (EN 50 082-2) fulfilled

IEC 1000-4-2 / EN 61000-4-2 level 3 (8 kV) fulfilledIEC 1000-4-3 / ENV 50140 level 3 (10 V/m) fulfilledIEC 1000-4-4 / EN 61000-4-4 level 4 (4 kV) fulfilledIEC 1000-4-6 / ENV 50141 level (10 kV) fulfilled

Vibration test DIN IEC 68 fulfilledTest of cycles cycles ≥ 10 millionsWeight kg 0,30

0,5

0,1 … 0,254

0,4 … 0,66

0,1 … 1,610

2 … 415

5 … 1030

11 … 1630

0,35 0,2

Nominal size d (mm)22 mm 34

38 mm (11⁄2’’’) 50,551 mm 64

63,5 mm 77,5

Construction and FunctionPressure transmitter ED 522 consists of a pressure connection section withwelded stainless steel diaphragm and a stainless steel case for housingthe electronic circuit and the electrical connection. The piezoresistivepressure sensor is mounted right behind the diaphragm (except for thetypes ED 522/xAx and ED 522/xBx). The pressure being measured istransmitted by the external diaphragm and the oil filling to the measuringdiaphragm of the piezoresistive silicon sensor.

An amplifier converts the pressure sensor’s bridge signal to the desiredsignal level. The amplifier space is sealed to provide optimal shock andvibration resistance. The transmitter has a clamp connection for quickmounting.Access to the adjusting potentiometer is obtained by unscrewingthe closure ring. Both zero point and range can be adjusted with ascrewdriver.

Dimensions ED 522/xAx.xxxED 522/xBx.xxx

–0,5 bar

0 bar

p rel

–1 bar

prohibitedzone

Medium pressure

pabs

1 bar

0,5 bar

1 mbar0–50 0 50 100 200 300 Medium temperature °C

120

Clamp ring

Gasket

Clamp liner

S._31-36_Kat.Elekt.E 18.01.2001 15:38 Uhr Seite 32

Page 74: A1 Electronic Pressure

D6.170 E / 1.01Design and specifications subject to change without notice

Ordering example: ED 530 / 3 1 4 . 2 1 1 / 025

System design ED 530EEx ib IIC (ATEX)1) EDX 530

Pressure type Gauge pressure 3Absolute pressure 4

Static error band 0,4% FS (Tmed = 25˚C), comp. temp. -00 … 50°C 1(Tamb = 25˚C) 0,2% FS (Tmed = 25˚C), comp. temp. -10 … 50°C 2

0,4% FS at specified adjusted temp.2) 70,2% FS at specified adjusted temp.2) 8

Electrical connect. Cable 2 m IP 653) 1Plug Bendix IP 653) 2Plug DIN 41 524 (Binder) IP 653) 3Plug DIN 43 650 IP 653) 4Cable 2 m with relative tube IP 673) 9

Output signal IA = 0 … 20 mA 1IA = 4 … 20 mA 2UA = 0 … 10 V DC 4UA = 0 … 5 V DC 5

Pressure connect. G1⁄2 with cone 1G1 with cone 2

Diaphragm Stainless steel 1.4404/316 L 1Hastelloy C-276 2Stainless steel, gold plated 9

Pressure range also other pressure ranges and versions in Pa, psi, H2O etc. available

Order Pressurecode range

mbar126 0 … 100136 0 … 160A56 0 … 200

146 0 … 250156 0 … 400A66 0 … 500166 0 … 600

bar025 0 … 1035 0 … 1,6A15 0 … 2045 0 … 2,5055 0 … 4A25 0 … 5

065 0 … 6075 0 … 10075 0 … 10

085 0 … 16A35 0 … 20095 0 … 25105 0 … 40A45 0 … 50

Con-nect.

G1G1G1

G1G1G1G1

G1G1G1G1G1G1

G1G1G1⁄2

G1⁄2G1⁄2G1⁄2G1⁄2G1⁄2

Con-nect.

G1⁄2G1⁄2G1⁄2

G1⁄2G1⁄2G1⁄2

G1G1G1G1G1G1

G1G1G1

G1G1

Order Pressurecode range

bar115 -100 … 60125 -100 … 100135 -100 … 160

A55 0… -200145 0… -250155 0… -400

mbarD06 -0… -100D26 0… -200D56 0… -500H66 -100… -100H76 -200… -200H86 -500… 500

barD85 -0 … -1H05 -1 … -1525 -1 … 3

535 -1 … -5545 -1 … -9

Pressure Transmitter for High Temperaturewith Flush Diaphragm ED 530

Selection Chart

1) Version 4 … 20 mA only (with IP 42)2) Temperature adjustments

If the adjustment of the media temperature deviates from 25°C, ther order code must be defined with /9007/XXXX.Ordering example: adjustment on 150°C, order code /9007/0150. The compensated temperature range is ±25°C of the adjusted temperature. If the adjusted temperature is above 125°C, the compensated temperature range will always be 100°C to 150°C.

3) Not available for EEx.

Special Designs see D6.901 E / Accessories see D6.911 E

Electrical Connection (Pin assignments and cable colours see D0.320 E)

IA = 4 … 20 mA IA = 0 … 20 mA, UA = 0 … 5 V, UA = 0 … 10 V

Application Measurement of absolute and relative pressure ofgases and liquids for temperatures up to 300°C

Construction Flush diaphragmSeal either flush (for food applications) or behindthread according to DIN 3852 form AExternal zero point and span adjustment

Pressure range 100 mbar … 400 bar

Output signal 0 … 20 mA, 4 … 20 mA,0 … 5 V DC, 0 … 10 V DC

Static error band ≤ 0,25% FS typ., ≤ 0,15% FS typ.

Medium temperature –40 … 300°C

Electrical connection Cable or plug

Pressure connection Male thread G1⁄2, G 1 with cone

Type of protection IP 65, IP 67

EMC Protected for industrial environments, conformingto EN 50081-2, EN-50081-1 and EN 50082-2

Accessory Test certificate

S._31-36_Kat.Elekt.E 18.01.2001 15:38 Uhr Seite 33

Page 75: A1 Electronic Pressure

Pressure range 1 0 … +P barMaximal Pressure P max. barDeviation of characteristic ED 530/x1 ± % FS ≤ 0,25 typ./0,4 max.(see diagram D0.320)curve (Tamb = 25°C) ED 530/x2 ± % FS ≤ 0,15 typ./0,2 max.(see diagram D0.320)Hysteresis and reproducibility ± % FS ≤ 0,2 (p < 0,4 bar) / 0,1 (p ≥ 0,4 bar)TC zero point1) ± % FS/10 K ≤TC sensitivity1) ± % FS/10 K ≤ 0,2Operating temp. (medium) °C –40 … 300 (see diagram medium pressure)Housing temperature2) °C –20 … 80Storage temperature °C –40 … 80Supply voltage UB IA = 0 … 20 mA V DC –16 … 30

IA = 4 … 20 mA V DC –10 … 30 (see diagram)UA = 0 … 5 V DC V DC –09 …30UA = 0 … 10 V DC V DC –14 … 30

Reverse polarity protection for supply voltage UB yesShort circuit proof output yesOvervoltage protection yesLoad (RL + RLine) IA = 0 … 20 mA Ohm ≤ 500

IA = 4 … 20 mA Ohm ≤ 1000 (see diagram D0.320)UA = 0 … 5 V DC kOhm ≥ 5UA = 0 … 10 V DC kOhm ≥ 10

Zero point adjusting range ± % FS 2Insulation resistance at 750 V DC MOhm ≥ 1,2Type of protection (DIN 40 050, IEC 144) according selection chartEMC emission (EN 50 081-1 and -2) fulfilledEMC immunity (EN 50 082-2) fulfilled

IEC 1000-4-2 / EN 61000-4-2 level 3 (8 kV) fulfilledIEC 1000-4-3 / ENV 50140 level 3 (10 V/m) fulfilledIEC 1000-4-4 / EN 61000-4-4 level 4 (4 kV) fulfilledIEC 1000-4-6 / ENV 50141 level (10 kV) fulfilled

Weight kg 0,25

D6.170 E / 1.01Design and specifications subject to change without notice

Pressure Transmitter for High Temperaturewith Flush Diaphragm ED 530

Construction and Function

Medium pressureAdmissible medium pressure as a function of medium temp.

Dimension chart

Plug Bendix DINL2 12,5 10

1,83)

Technical Data

0,14

0,16…0,254

0,4…0,66

1…1,610

2…415

5…1030

16…2575

40…60100

100…160250

200…400600

1,03) 0,5) 0,35) 0,2/0,43) 0,23) 0,23) 0,23) 0,23)

Dimensions

D h1 h2 L1

G1⁄2’’ 22 85 96,5

G1’’ 27 89 91

1) Calibration temperature ± 25°C.2) The ambient air should not rise above 50°C; otherwise the temperature of the transmitter section may exceed the admissible limit.3) For pressure connection G1⁄2.

The pressure transmitter for high temperature duty consists of apressure connection with its heat-resistant welded inox pressure trans-mitting diaphragm and an inox transmitter section containing the elec-tronics and the electrical connection. The pressure sensor is located inthe transmitter section and is separated from the pressure connectionsection by a capillary tube.

Four inox rods link the pressure connection to the transmitters sectionin orders to avoid mechanical stress to the capillary tube. The pressuresensor’s signal is converted by an amplifier to a signal of 0 … 20 mA,4 … 20 mA, 0 … 5 V DC oder 0 … 10 V DC.The transmitters are equipped with external zero point and span adjust-ment.

p rel

0 bar

–0,5 bar

–1 bar

cable compressionfitting

plastic sheath ofgrey PVCcore cross-section: 0,34 mm2

tin-platedcopper cloth

prohibitedzone

Medium pressure

Medium temperature (°C)

plug

screw in-torque: 60 Nm(85 Nm for 1000 bar)

zero point adjustment

span adjustment

cable

S._31-36_Kat.Elekt.E 18.01.2001 15:42 Uhr Seite 34

Page 76: A1 Electronic Pressure

D6.192 E / 1.01Design and specifications subject to change without notice

Ordering example: ED 552 / 3 1 1 . 1 1 1 / 126 / 9001 / 0100

System design EDX 552EEx ia II C (ATEX)1) EDX 552

Pressure type Gauge pressure 3Static error band 0,5% FS (Tmed = 20˚C), comp. temp. -5 … 30°C 1(Tamb = 20˚C) 0,3% FS (Tmed = 20˚C), comp. temp. -5 … 30°C 2

0,2% FS (Tmed = 20˚C), comp. temp. -5 … 30°C 3Electrical connect. Cable 2 m with relative tube 1Output signal IA = 0 … 20 mA 1

IA = 4 … 20 mA 2UA = 0 … 10 V DC 4UA = 0 … 5 V DC 5

Pressure No protection, flush 1connection Protection grating 2protecting pieces Stainless steel cap with G1⁄4’’ female thread and grating 3to be screwed

Protection grating ø 52 mm stainless steel, hemispherical 4Stainless steel cap with grating 7

Diaphragm Stainless steel 1.4404/316 L 1Hastelloy C-276 2

Pressure range also other pressure ranges and versions in Pa, psi, H2O etc. availableCable length

Order Pressurecode range

mbar126 0 … 100136 0 … 160A56 0 … 200

146 0 … 250156 0 … 400A66 0 … 500166 0 … 600

bar025 0 … 1035 0 … 1,6A15 0 … 2

045 0 … 2,5055 0 … 4A25 0 … 5065 0 … 6

075 0 … 10085 0 … 16A35 0 … 20

095 0 … 25105 0 … 40A45 0 … 50

Pressure Transmitter for HydrostaticDepth Measurement ED 552

Selection Chart

1) Version 4 … 20 mA only

Special Designs see D6.901 E / Accessories see D6.911 E

Application Water level measurement in fountains,bore holes, vessels or still waters

Construction Stainless steel 1.4435

Pressure range 100 mbar … 50 bar

Output signal 0 … 20 mA, 4 … 20 mA0 … 5 V DC, 0 … 10 V DC

Static error band 0,4% FS typ., 0,25% FS typ., 0,15% FS typ.

Electrical connection Cable with reference air pipe

Pressure sensor Exchangeable protection cap to avoid damages

Type of protection IP 68

EMC Protected for industrial environments, conforming to EN 50081-2, EN-50081-1and EN 50082-2

Accessory Test certificate

(please see alsochart on the reverse)

Ord

erin

g co

de

for

cab

le le

ngth

Cab

le le

ngth

in d

me.

g. L

= 1

0 m

Electrical Connection (Pin assignments and cable colours see D0.320 E)

IA = 4 … 20 mA IA = 0 … 20 mA, UA = 0 … 5 V, UA = 0 … 10 V

S._37-38_Kat.Elekt.E 18.01.2001 15:44 Uhr Seite 37

Page 77: A1 Electronic Pressure

D6.192 E / 1.01Design and specifications subject to change without notice

Pressure range 1 0…+P bar

Maximum Pressure P max. bar

Deviation of characteristic ED 552/31x.xxx ± % FS ≤ 0,4 typ./0,5 max. (see diagram D0.320 D)curve (Tamb = 25°C) ED 552/32x.xxx ± % FS ≤ 0,25 typ./0,3 max. (see diagram D0.320 D)

ED 552/33x.xxx ± % FS ≤ 0,15 typ./0,2 max. (see diagram D0.320 D)

Hysteresis and reproducibility ± % FS ≤ 0,2 (p < 0,4 bar) / 0,1 (p ≥ 0,4 bar)

TC zero point ± % FS/10 K ≤TC sensitivity ± % FS/10 K ≤ 0,25

Operating temp. (medium) comp./not comp. °C –5 … 30 / –5 … 60

Housing temperature °C –20 … 60

Storage temperature °C –40 … 80

Supply voltage UB IA = 0…20 mA V DC –16 … 30

IA = 4…20 mA V DC –10 … 30

UA = 0…5 V DC V DC –09 …30

UA = 0…10 V DC V DC –14 … 30

Reverse polarity protection for supply voltage UB yes

Short circuit proof output yes

Overvoltage protection yes

Load (RL + RLine) IA = 0…20 mA Ohm ≤ 500

IA = 4…20 mA Ohm ≤ 1000

UA = 0…5 V DC kOhm ≥ 5

UA = 0…10 V DC kOhm ≥ 10

Insulation resistance at 750 V DC MOhm ≥ 1,2

Type of protection (DIN 40 050, IEC 144) IP 68

EMC emission (EN 50 081-1 and -2) fulfilled

EMC immunity (EN 50 082-2) fulfilled

IEC 1000-4-2 / EN 61000-4-2 level 3 (8 kV) fulfilled

IEC 1000-4-3 / ENV 50140 level 3 (10 V/m) fulfilled

IEC 1000-4-4 / EN 61000-4-4 level 4 (4 kV) fulfilled

IEC 1000-4-6 / ENV 50141 level (10 kV) fulfilled

Weight (without cable) kg 0,16

0,3

Pressure Transmitter for HydrostaticDepth Measurement ED 552Technical Data

Construction and FunctionThe transmitter consists of a pressure part with a welded stainless steeldiaphragm and a stainless steel housing with built-in electronics. Theconnecting cable is mounted to case. Several parts to protect thediaphragm (caps, gratings) may be screwed. The pressure sensitivesilicon sensor is located behind the diaphragm. Atmospheric pressureis led to the interior of the sensor via the integrated air pipe of the cable.The water level is exerted on the oil – and thus on the sensor – as a

hydrostatic pressure over the diaphragm. A a result of the piezoresisti-ve effect, the resistors change their values linearly with the water level.The resistance bridge therefore generates a signal proportionally to thedifference between the hydrostatic and the atmospheric pressure. Theintegrated amplifier transforms the signal into a current of 0 ... 20 mAresp 4 ... 20 mA. Changes in atmospheric pressure don’t have anyinfluence to the measurement.

0,1…0,25

4

0,4…0,6

6

0,1…1,6

10

2…4

15

5…10

30

16…25

75

50

75

0,25 0,2 0,2 0,2 0,2

Ordering code for the individual protection capsED 552/XXX.X1X Pressure transmitter (Pos.1) no capED 552/XXX.X2X Pressure transmitter (Pos.1) with protection grating D 12583.0000 and cap (Pos. 2) D 12582.001ED 552/XXX.X3X Pressure transmitter (Pos.1) with protection grating D 12583.0000 and cap with female thread (Pos. 3) D 12582.0003ED 552/XXX.X4X Pressure transmitter (Pos.1) with hemispherical protection grating (Pos. 4) D 12582.0000ED 552/XXX.X7X Pressure transmitter (Pos.1) with protection grating and stainless steel cap (Pos. 7) D 12582.0002

Dimensions

4 3 7 2 1

Alu strip screening

Tinned copper braid

Air pipe

Plastic sheath of black polyethyleneCore cross-section 0,34 m2

Air pipe Ø = 1,3 mm

S._37-38_Kat.Elekt.E 18.01.2001 15:44 Uhr Seite 38

Page 78: A1 Electronic Pressure

made to measure

Data Sheet A11 D6.180

Pressure Transmitter ED 701

Hygienic and industrial process connections

Zero setting function

Accuracy < 0,1% FS

Quick response time < 25 ms

High long-term stability

Excellent repeatability

Active compensation for temperature drifts

4 ... 20 mA and Voltage outputs

Complete range of electrical connections

ATEX II 1 G, EEx ia IIC T4 / T6 (Pending)

CIP/SIP

Description

The ED 701 is a pressure transmitter available in 4 ... 20 mA current loop or in voltage output signal versions. This transmitter offers a very high ac cu ra cy over a wide tem per a ture range, an excellent repeatability and very long term sta bil i ty.

The piezo-resistive sil i con sensor is anodic bond ed on a very stable glass base, which is attached to a stainless steel con struc tion. This assembly guar an ties an excellent ther mal isolation.The sensor is isolated from the process by a stainless steel diaphragm (1.4404 / 316L) and a fi lling liquid.

The electronics are located within the hermetically sealed trans- mit ter housing which give the ED 701 an excellent re sis tance to humidity, shock and vibration. Protection class, from IP 65 to IP 67 only de pends on the choice of the electrical connection.

The electronics are a state-of-the-art signal processing unit fi tted with a fast micro-controller allowing the com pen sa tion of drift effects due to temperature on the sensor sig nal, over a wide temperature range with a fast response time.

The ED 701 is available with a great variety of pres sure and electrical connections to meet all requirements. The elec tri cal connection can be replaced easily and gives ac cess to the Auto-zero adjustment.

The ED 701 is a very fl exible transmitter suitable for all types of applications and more specifi cally for food and beverage, phar-maceutical, and biotech ap pli ca tions.

Page 79: A1 Electronic Pressure

Data Sheet A 11 D6.180

Ordering Details

Ordering code digit 1 2 3 4 5 6 7 8 9 10 11 12

Raccordement au processusMale thread G1⁄2” EN 837 1 Male thread G1⁄4” EN 837 2 Male thread M20x1,5 EN 837 3 Male thread G1⁄2” DIN 3852 with O’ring3) 4 Male thread G1⁄8” EN 837 5 Female thread G1⁄2” DIN 3852 6 Female thread G1⁄4” DIN 3852 7 Male thread 1⁄2”- 14NPT, ASP N152 A Female thread 1⁄4”-18NPT, ASP N152 B Male thread 7/16- 20UNF EMale thread G1” fl ush diaphragm cone3) J Male thread G1” fl ush diaphragm O’ring3) K Male thread G1⁄2” fl ush dia. DIN 3852 (Combi Connect)3, 4) L Clamp DN 38, ISO 28521) N Clamp DN 51, ISO 28521) P Clamp DN 64, ISO 28521) Q

Output signal4 ... 20 mA 2 0 ... 10 V DC 4 0 ... 5 V DC 5 Approvals

None 0ATEX (pending) 1CSA (pending) 2

Electrical connection2 meter shielded cable 3 conductors 1 Fischer Plug (IP 67)2) 2DIN 41524 Binder Plug 3 DIN 43650 Plug 4 Bendix 6 pole Plug 5 M12, 4 pole Industrial Plug 6 1⁄2” NPT, cable length 1 m (IP 67) 7 2 meter shielded cable 3 conductors, IP 67 9 Field Housing IP 67 (cable diameter 5 to 12 mm) A

Accuracy 0,4% FS, Compensated Temperature –10 ... 80°C 10,2% FS, Compensated Temperature –10 ... 80°C 20,1% FS, Compensated Temperature –10 ... 80°C 3

1) Pressure range up to 20 bar. Maximum pressure depends on clamp fork.Operating temperature must be considered.

2) Cable socket included.3) See code 10 for O’ring selection.4) Pressure range from 1 bar with Combi Connect.

Page 80: A1 Electronic Pressure

Ordering details (continued)

Ordering code digit 1 2 3 4 5 6 7 8 9 10 11 12 Pressure units

Gauge pressure 3Absolute pressure 4Negative gauge pressure (Pending) 5

Pressure range1) 100 mbar up to 40 bar: gauge pressure See code500 mbar up to 40 bar: absolute pressure below

1) Avec Combi Connect, à partir de 1 bar

Wetted parts All Stainless Steel 1O’ring NBR* 5O’ring Viton* 6O’ring EPDM* 7

* See code 1 for pressure connection

Oil fi lling

Standard, Silicon 0FDA approved white oil 1Silicon free / oxygen service (Pending) 2

Pressure range details

Code Range Code Range Code Range mbar bar bar

126 0...100 025 0...1 095 0...25136 0...160 035 0...1,6 105 0...40A56 0...200 A15 0...2 146 0...250 045 0...2,5 156 0...400 055 0...4 A66 0...500 A25 0...5 166 0...600 065 0...6

Data Sheet A11 D6.180

Page 81: A1 Electronic Pressure

Technical data

Measurement characteristics

Pressure range Gauge pressure 0...100 mbar, 0...40 bar Abs. pressure 0...500 mbar, 0...40 barPressure ranges available within the defi ned ordering code.

AdjustmentAuto-Zero function by press-button located behind the electrical plug.Please remove plug to get access.

Overpressure At least 3 times nominal value

Accuracy According to ordering code 4

Hyteresis and repeatability +/- 0.05% FS

Long term stability +/- 0.2 % FS/year

Temperature infl uence (compensated range –10 ... 80°C)

Accuracy code 5 = 1 (+/-0,4% FS)TC zero = +/-0,3% FS/10KTC Span = +/-0,2% FS/10KAccuracy code 5 = 2 (+/-0,2% FS)TC zero = +/-0,2% FS/10KTC Span =+/- 0,15% FS/10KAccuracy code 5 = 3 (+/-0,1 %FS)TC zero = +/-0,05% FS/10KTC Span = +/-0,05% FS/10K

Response time 10 ... 90%, 25 ms

Electrical specifi cation

Supply voltage 10 ... 30 V DC

Insolation Resistance >1 GOhm, 500 V DC

Load RL < 50 x UB - 450

Infl uence of the Power supplyProtected against reverse signal po lar i ty.

Temperature characteristics

Operating Temperature-30 ...125 °C not compensated for wetted parts all in stainless steel-10°C ... 80 °C Compensated-20°C ... 125°C with Viton O’ring-30°C ... 120°C with EPDM O’ring-20°C ... 80°C with NBR O’ring

Compensated Temperature -10 ... 80°C

Sterilisation Temperature 140°C, 30 minutes

Storage Temperature-55° ... 150°C For version fi tted with O’ring seals, refer to operating Temp.

Temperature characteristics (FDA white oil)

Minimal temperature–10°C

Materials specifi cation

Wetted partStainless Steel W.1.4435 (fi tting body) and W.1.4404 (AISI 316L, diaphragm)

Parts not in contact with mediumStainless Steel W.1.4301 (housing), W.1.4305 (AISI 304 connec-tor base) and elec tri cal con nec tor material.

Certifi cate EN10204 3.1B available on request

EMC

Infl uence of EMC Less than 0,15% FS

Data Sheet A 11 D6.180

Page 82: A1 Electronic Pressure

Technical data

Environmental specifi cation

Humidity According to EN 60068-2-38

Vibrations According to EN 60068-2-6

Shocks According to EN 60068-2-6

SterilisationComplete device, not powered, only fl ush diaphragm versions (without O’ring seal) and Fischer electrical plug.Process duration 60 minutes, not powered, sterilisation tempera-ture max. 140°C, pressure 3500 mbar.

Protection class

Rating IP 65 and IP 67, Depending on electrical plug.

Mounting

Position at calibration time: Vertical

Switch ON time

5 sec.

Test Certifi cate

Delivered with the transmitter. Test certifi cate, 6 points risingat ambient temperature (Tamb = 25°C).

Physical characteristics

Weight Between 223 and 885 g depending of the version.

DimensionsSee drawings.

Zero setting function

The Zero setting function is available directly on the device by removing the electrical plug. The Zero is ac ti vat ed pressing the push button located on the top of the electronic unit. Pressing

the Zero button will cause the applied pressure to be considered as zero. This function allows ini tial iza tion of the zero point e.g. in level measurement.

Data Sheet A11 D6.180

Page 83: A1 Electronic Pressure

Drawing

DIN 43650 plug Bendix 6 pole plug Cable 3 conductors DIN 41524Binder plug

34 34 34 34

17 20

10.4 17

key 27key 27

key 41

d3

d2

d1

d1

d1

d2

l 1

l 1l 2l 1

l 2

l 323 25

12

70°

Mounting example

Thread d1 d2 d3 l1 l2 l3G1⁄2 6 17,5 20 5 3M20x1.5 6 17,5 20 5 3G1⁄4 6 9,5 11 3 2G1⁄8 6 8 8 2,5 2

Thread d1 l1 G1⁄2 141⁄2-14NPT 20

Thread d1 d2 l1 l2 G1 20 9 18

Seal

Seal

Screw hole

Screw hole

Screw hole

Pressure port

Pressure port

Pressure port

Data Sheet A 11 D6.180

Page 84: A1 Electronic Pressure

Drawing

Fischer plug NPT 3 conductors M12 industrial plug Field housing

34 34 34 55

17 13

10.4

50

34

61.5

Thread d1 d2 l1 l2G1 30 12,5 20,5

Thread d1 d2 l1 l27/16-20UNF 9,2 4,5 9

Thread d1 d2 l1 l2G1⁄2 6 20 5G1⁄4 28 14 17,51⁄2-18NPT 28 10,2 12,5

Clamp d1 l1 50.5 1564 1577.5 15

Mounting example

Seal

Seal

Seal

key 41

d2

d1

l 1

l 212

key 27

d2

d1

l 1l 2

23

l 3

45°

key 27

d2

d1

l 1 l 223

d1

l 1

Screw hole

Screw hole

Screw hole

Pressure portPressure port

Pressure port

Pressure port

Clamp

Data Sheet A11 D6.180

Page 85: A1 Electronic Pressure

E/2

003-

01-0

1 Th

is d

ata

shee

t m

ay o

nly

be

rep

rod

uced

in fu

ll.

Connecting diagram

Electrical connection

For Voltage signal Output 0 … max. 10 V For 4 ... 20 mA current loop version

Pin assignment

Contact DIN 43650 plug Bendix 6 poles plug Cable 3 conductors DIN 41524 Binder plug

4...20 mA Voltage 4...20 mA Voltage 4...20 mA Voltage 4...20 mA Voltagea 1 1 B B Blue Blue 3 3b 2 2 E E Brown Brown 1 1c - 3 - D - Black - 4d GND GND Case Case Case Case

Viewsoldering side,cable socket 3

2 1

AF

ED

C

B

1

23

4

5

Pin assignment

Contact Fischer plug NPT 3 conductors M12 industrial plug Field housing

4...20 mA 0...5/10VDC 4...20 mA 0...5/10VDC 4...20 mA 0...5/10VDC 4...20 mA 0...5/10VDCa 1 1 Red Red 3 3 1 1b 2 2 Black Black 1 1 2 2c - 3 - Green - 4 - 3d Case Case Case Case 4 4

Viewsoldering side,cable socket

1 2

341

34

2 1 2 3 4

red blackgreen

blue

blackbrown

+

a

b

c

d

IA

UA RL

UB +

UB

RLIA

a

b

d

Data Sheet A 11 D6.180

Page 86: A1 Electronic Pressure

1

Description

Turn Down up to 1:16

Accuracy better than 0.1%

High long term stability

Diff. pressure range 3.75 mbar...20 bar

Line pressure up to 140 bar

HART® communication

Zero adjustment

Damping

Robust and modular design

Square root output (FKK)

Linearisation table (FKK)

Analogue or digital display (Option)

The EDD575 differential pressure transmitter accuratelymeasures differential pressureand transmits a4...20mA/ HART® signal based on linear output orsquare root (FKK).

0.1% accuracy for all configured spans is the standardfeature covering differential ranges from 0.0375 bar to20 bar.

The micro-capacitance silicon sensor element assuresthis accuracy for all elevated or suppressed measuringranges without additional adjustment. Silicon has greatmechanical properties, such as no hysteresis featuringan excellent repeatability.

The compensation data is stored in the sensor device,making it possible to replace the electronics unit, theHART® communication module and the local indicatorswithout re-calibrating the complete assembly.

The HART® communication module can be configuredwith a standard HART® communicator.

Analogue and digital indicators can be mounteddisplaying individual read-outs.

The EDD575 is suitable for a wide range of processapplications in differential pressure, level and flowmeasurements.

EDD575 Differential Pressure TransmitterEDD575-1

Page 87: A1 Electronic Pressure

Technical Data

Static pressure, span and range limits

Static RangeType pressure FHK FKK FHK/FKK limit

(bar) Min. Min. Max. (mbar)FxKx12 ´-1...32 6 3.75 60 ±60FxKx33 ´-1...140 32 20 320 ±320FxKx35 ´-1...140 130 81.25 1300 ±1300FxKx36 ´-1...140 500 312.5 5000 ±5000

FxKx37 ´-1...140 2000 1250 20000 ±20000

Span limits (mbar)

Process connection1/4-18 NPT, meets DIN 19213.

Static pressure - lower limit

Output linearization(Model FKK only)14 points linearization table configurable from HHC.

Accuracy for lineary output(including linearity, hysteresis and repeatability)

Span > 1:10 of URL: ±0.1% of span

Span < 1:10 of URL (model FKK only):

± (0.05 + 0.05(0.1 x URL/Span))% of span

Accuracy for square root output(Model FKK only)

Output Span > 1:2.5 of URL

50..100% ±0.1%

20...50% ±0.25%

10..20% ±0.5%

Output Span < 1:2.5 of URL

50..100% ±(0.05 + 0.05 x 0.1 x URL/span)%

20...50% ±2.5 x (0.05 + (0.05 x 0.1 x URL/span))%

10..20% ±5 x (0.05 + (0.05 x 0.1 x URL/span))%

Communication(Model FKK only)

Notes1 A standard HHC (e.g. model 275) must be higher thanversion 5.0 or a FXW####1-#2 must be used,e.g. FXW 28AA1-A2

2 HHC must be higher than version 5.3

Items Display Set Display SetTag no. x x x x

Model no. x x

Serial no. Yes x Engineering unit x x x x

Range limit x x

Measuring range x x x xDamping x x x x

Output mode x x x x

Burnout direction x x xAdjustment x x x x

Output adjust x x x xData x x

Self diagnoses x x

Printer x External switch lock x x x x

Display 1 x x

Linearise 2 x xRe-range 2 x x

HART® Protocol FXW Protocol

Operatingpressure

mbar (abs)

1010

200

40

27

0

Operating area

Silicone Oil:

-40 60 100 °C

Process temperature

Fluorinated oil:660 mbar abs at temperatures below 80°C

Static pressure - overrange limitDiff. pressure < 60 mbar: 32 barDiff. pressure > 60 mbar: 140 bar

MediaLiquid, gas or vapour

Unit conversion1MPa=103kPa=10bar=10.19716kgf/cm2=145.0377PSI

1kPa=10mbar=101.9716mmH2O=4.01463inH

2O

OutputModel FHK: 4...20mA, 2-wire, linear

Model FKK: 4...20mA, 2-wire with HART®

linear or square root

Normal / reverse outputModel FHK: Selectable with a jumper pin located on theelectronics unit.

Model FKK: Selectable from the Hand Held Communicator

Page 88: A1 Electronic Pressure

Technical Data

Zero and span adjustmentModel FHK and FKK:Zero and span are adjustable with an external adjustablescrew. The function is determined with the MODE switch.MODE FunctionZero Adjust zeroSpan Adjust spanInhibit Disable adjustment screw

Model FKK only:Span Adjustable with the Hand Held Communicator

Zero Adjustable with the Hand Held Communicator

Zero elevation / suppression–100...100% of URL

Low flow cut-offUser configurable for any point between 7...20% ofoutput (Model FKK only)

Burnout directionIf the self-diagnostic function detects a transmitterfailure, the analog signal will be driven to either "OutputHold", "Output Overscale" or "Output Underscale" modes.

Model FHK: Unless otherwise specified in the order, thetransmitter will be shipped in "Output Hold" mode.

Model FKK: Selected from HHC

"Output Hold": Output signal is hold as the value justbefore failure happens.

"Output Overscale": Approx. 21.6 mA(Adjustable within 20.8...21.6 mA with the HHC)

"Output Underscale": Approx. 3.8 mA(Adjustable within 3.2...3.8 mA with the HHC)

Underscale Nominal output Overscale

Lineary output

3.2 3.8 4.0 20 20.8 21.6 mA

Loop-check outputModel FHK: The transmitter can output a constant signalof 4mA, 12mA or 20mA if the MODE switch is set to „loopcheck“ mode.

Model FKK: Transmitter can be configured to provide aconstant output of 3.8...21.6mA by HHC.

IndicationAnalog indicator or 4 ½ digit LCD meter

Power supplySupply range 10.5...45V DC

Arrester option 10.5V...32V DC

Load limitationsNote: Communication with a handheld communicatorrequires a min. circuit resistance of 250 Ohms.

Operational conditionsAmbient temperatureStandard model –40...85°C

With LCD indicator –20...80°C

With Arrester option –40...60°C

With Fluorinated oil filling –10...60°C

Process temperatureSilicone oil filling –40...100°C

Fluorinated oil filling –20...80°C

Storage temperature –40...90°C

Humidity 100% RH

Mounting position effectPer 10° tilt in any plane

Span: No effect

Zero shift: < 1.2mbar for silicone oil

Zero shift: < 2.4mbar for flourinated oil

This error can be corrected by adjusting Zero.

Temperature effect - Lineary outputPer 28°C change at the process connectionin the range –40...85°C:

Ordering code Effect(6th digit)

„2“ Zero: ±(0.25 x URL/span)%Total: (Zero effect + 0.25)%

„3, 5, 6, 7“ Zero: ±(0.1 x URL/span)%Total: (Zero effect + 0.075)%

Temperature effect - Square root output(Model FKK only)

Per 28°C change at the process connectionin the range –40...85°C:

Ordering code Shift at 20% output point(6th digit)

„2“ ±(0.625 x URL/span) %„3, 5, 6, 7“ ±(0.25 x URL/span) %

Ohm

2000

15331500

1000

600500250

10.5 16.1 24 45 Volt

Operating area

Page 89: A1 Electronic Pressure

Technical Data

Static pressure effectOrdering code Effect(5th digit)

„1“ (per 32 bar) Zero: ±0.4% of URLSpan: ±0.4% of span

„3“ (per 100 bar) Zero: ±0.2% of URLSpan: -0.5...0% of span

Overrange effectOrdering code Effect(5th digit)

„1“ (per 32 bar) Zero: ±0.4% of URL

„3“ (per 140 bar) Zero: ±0.4% of URL

Supply voltage effectLess than 0.05% of span per 10V.

RFI effectLess than 0.2% of URL for the frequencies of 20 to1000MHz and field strength 30 V/m when electronicscovers on.

(Classification: 2-abc: 0.2% span per SAMA PMC 33.1)

Stability0.2% of upper range limit (URL) for 24 months

(In case of 6th digit ordering code "3", "5", "6", "7")

DampingModel FHK:Time constant fixed: 0; 0.3; 1.2; 4.8; or 19.2 sec.

Model FKK:Time constant adjustable in the range 0...38.4 sec.

Step response(without electrical damping)

Ordering code Time Constant Dead Time(6th digit)

„2“ 0.85 sec. 0.3 sec.

„3“ 0.45 sec. 0.3 sec.

„5, 6, 7“ 0.2 sec. 0.3 sec.

EMC dataImmunity EN 50082-2

Emission EN 50081-1

Approval EEx ia IIC T4/T5Temperature class T1...T4: -40 < Tamb < 85°C

T1...T5: -40 < Tamb

< 70°C

Barrier data U < 30 VDC

; I < 0.1 A; P < 0.75 W

Zones Media: 0; Housing: 0

Wetted parts materialProcess cover, wetted sensor body and vent/drainAISI 316 (W.1.4436 or W.1.4401)

DiaphragmAISI 316L (W.1.4404 or W.1.4435)

Sensor gasketViton O-rings or PTFE square section gasket.

Non-wetted parts materialElectronics housing

Low copper die cast aluminum alloy (standard), finishedwith epoxy/polyurethane double coating.

Bolts and nuts

Cr-Mo alloy (standard):AISI 316 (W.1.4436) or AISI 630 (W.1.4542)

Mounting bracket AISI 304 (W.1.4301)

Filling fluidSilicone oil (standard) or fluorinated oil (Daifloil)

Other mechanical dataProtection class IP67 and NEMA 4X

Mounting On 50mm (2") pipe usingmounting bracket,direct wall mounting ordirect process mounting.

Weight 3.4kg without options.

+ 0.5kg for mounting bracket

+ 0.8kg for indicator (option)

Electrical connectionsG1/2, 1/2-14 NPT, Pg13.5 or M20 x 1.5 conduit

Other electrical dataDielectric strength 500 V AC ,50/60 Hz, 1 min.

between circuit and earth

Insolation resistance > 100 Mohm at 500 V DC

Power-on time 4 sec.

Internal resistance for external field indicator: < 12 Ohm

Optional featuresIndicatorA plug-in turnable analog indicator (1.5% accuracy) canbe located in the electronics compartment or in theterminal box of the housing.

An optional 4½ digits LCD meter is also available.

ArresterA built-in arrester protects the electronics from lightningsurges.

Lightning surge immunity: 4KV (1.2 x 50µs)

Oxygen measurementSpecial cleaning procedures are followed throughout theprocess to maintain all process-wetted parts oil-free.

The filling fluid is fluorinated oil.

DegreasingProcess-wetted parts are cleaned, but the fill fluid isstandard silicone oil.

Not for use for oxygen or chlorine measurement.

NACE specificationMetallic materials for all pressure boundary parts complywith NACE MR-01-75. AISI316 stainless steel bolts andnuts, ASTM B7M or L7M bolts and 2HM nuts (Class II).

DiaphragmGold coating upon request

Page 90: A1 Electronic Pressure

Technical Data

Connection diagram

76

20

GND + - CK+ CK-

4...20 mA

and HART®

Analogue

display

AccessoriesOval flangesConverts process connection to 1/2-14 NPTMaterial AISI 316 (W.1.4436 or W.1.4401)

Three-valve manifoldAvailable in carbon steel or in AISI 316 (W.1.4436 orW.1.4401) stainless steel and in pressure rating 140 bar.

Hand-held communicatorModel FXW or model 275

Communication module(standard for model FKK)

When using this module for model FHK, remote settingfunction becomes available.

Note :When the communication module is connected, theoperation mode of external zero/span adjustable screw ischanged to zero adjustment only.

Test certificateTest certificate based on 5 measuring points up and downis included.

Optional stainless steel tagA stainless steel tag with customer data is wired to thetransmitter.

Page 91: A1 Electronic Pressure

Ordering Details

FxK xxxx xxxx xxxxHK

TVWX

12V33V35V36V37V

1A1B1C1D1J1E1F1G1H1K1L1P1M1Q1S1N

AK

ACDF

YB

YGAN

AC

ACDEF

TypeOutput 4...20 mA (linear output)Output 4...20 mA + HART® communication (configurable linear or square root output)

Process connection Oval flange screw Electrical connection1/4 - 18 NPT 7/16 - 20 UNF 1/2 - 14 NPT1/4 - 18 NPT M10 or M12 3 PG13.51/4 - 18 NPT M10 or M12 3 M20 x 1.51/4 - 18 NPT 7/16 - 20 UNF PG13.5

Static pressure Span (max) Diaphragm Cover and body-1...32 bar -60...60 mbar 4 AISI316L AISI316-1...140 bar -320...320 mbar 4 AISI316L AISI316-1...140 bar -1.3...1.3 bar 4 AISI316L AISI316-1...140 bar -5...5 bar 4 AISI316L AISI316-1...140 bar -20...20 bar 4 AISI316L AISI316

Indicator ArresterNone noneAnalogue, 0...100% linear scale noneAnalogue, 0...100% square root scale noneAnalogue, customer scale noneAnalogue, double scale, please specify noneNone yesAnalogue, 0...100% linear scale yesAnalogue, 0...100% square root scale yesAnalogue, customer scale yesAnalogue, double scale, please specify yesDigital, 0...100% noneDigital, customer scale (FKK only) noneDigital, 0...100%, square root scale noneDigital, 0...100% yesDigital, customer scale (FKK only) yesDigital, 0...100%, square root scale yes

Ex ApprovalNone (standard)EEx ia IIC T4/T5

Side vent/drain Mounting bracketNone NoneNone Yes, stainless steelYes NoneYes Yes, stainless steel

Tag plateNoneYes

Treatment Filling fluidNone (standard) Silicone oilDegreasing Silicone oilOxygene application Fluorinated oilNACE, Note 5 Silicone oil

Process cover gasket in stainless steel flangeVitonPTFE square section gasket

Bolts materialCr-Mo (standard)NACE (ASTM A193 B7M bolts and A194 2HM nuts)NACE (ASTM A320 L7M bolts and A194 2HM nuts)AISI 316 bolts and AISI 316 nuts, Note 5AISI 630 bolts and AISI 304 nuts

EDD 575 differential pressure transmitter

Page 92: A1 Electronic Pressure

Fastener(Ex version only)

Zero/ span adj. screw

10

4

ø80

120

45.5

12

6.5

"B"

Cable connection(4th digit)

U-boltM8

"A"

MTG pipeJIS 50A (2B)

4 holesø9 mm

Vent/drain plug

"C"

Cableconnection(4th digit)

11

088

50

70

193

30 58

38

UP

DOWN

Earth terminal(both sides)See table

Higherpressure

Oval flange screwScrew depth 13 mmSee table below

Lowerpressure

51 71 (27)

ø80

22

1

41.3

54

70

120

Details of "A" Details of "B“ Details of "C"Process Conduit ConduitConnection Connection Connection

ø7 ø15 ø13

2.5

8

G

ø18.5 D G1/2

EF

17

With field ind.(option)

Ordering Details

Dimensional Drawings

Symbol Process connection Oval flange screw Earth (4th digit) D E F G terminal

T 1/2 - 14 NPT 16 5 1/4 - 18 NPT 7/16 - 20 UNF No 8 - 32 UNCV PG13.5 8 4.5 1/4 - 18 NPT M10 or M12 M4W M20 x 1.5 16 5 1/4 - 18 NPT M10 or M12 M4X PG13.5 8 4.5 1/4 - 18 NPT 7/16 - 20 UNF M4

Conduit connector

Notes3 Static pressure < 100 bar: M10 bolts

Static pressure 100...140 bar: M12 bolts

4 See table page 2

5 Static pressure max. 100 bar

EDD575 Top view

EDD575 Side view

EDD575 Front view

Page 93: A1 Electronic Pressure

Data sheet A12.01

Design and specifications subject to change without notice

Sputtered thin film strain gauges

Absolute or gauge pressure

Tough environments

Very reliable

Long term stability

EF0 : 3 mV/V (1 to 600 bar) 2.2 mV/V (for 1000 bar)

Operating temperature: from cryogenic temperature to + 220°C

Technical Data (20°C)

EF0 Pressure transducer

Input voltage 10 Vdc (nominal) to 20 Vdc (max.)

Input impedance 1300 Ω ± 20%

Insulating resistance 100 M Ω / 100 Vdc at 25° C

Output signal 3 mV/Vdc ± 10% typ (± 25% max.) from 1 to 600 bar 2.2 mV/V ± 10% typ (± 25% max.) for M.R. 1000 bar

Output impedance 1250 Ω ± 30%

Initial zero offset ± 1% typ (± 3% max.)(% F.S.)

Global error ±0.2% F.S. typ (±0.30% max.)

Zero thermal shift ±0.005% F.S. typ (±0.01% F.S. max.)

Span thermal drift ±0.01% /°C (max)

Long term stability Zero: ± 0.2% F.S. (typ) over 5 years(at 20°C, atmospheric pressure) ± 0.5% F.S. (max.) over 5 years Span: ± 0.1% F.S. (typ) over 5 years ± 0.2% F.S. (max.) over 5 years

Vibrations specifications 20 g peak, from 5 to 2000 Hz(IEC 68-2-6)

Wetted parts P ≤ 6 bar : 15.5 PH steel + Hastelloy C276* P ≤ 10 bar : 15.5 PH steel* Body 15.5 PH steel*

Temperature ranges Operating -55...+150°C (option from cryogenic T° to +220°C) Compensated -30...+130°C Storage -60...+150°C

Shocks (IEC 68-227 test EA) 100 g - 6 msec - 1/2 sinus

Tightness IP 64 (gauge pressure) IP 65 (absolute pressure)

Pressure port G 1/4 female up to 400 bar AE 250C from 600 to 1000 bar

Tightening torque 10 to 60 Nm (female G 1/4) 35 Nm (AE 250C)

Electrical connection Six pins size 10 bayonet lock connector per MILC 26482G

Weight About 150 g

* 15.5 PH steel : refined version of 17.4 PH.

Page 94: A1 Electronic Pressure

Design and specifications subject to change without noticeData sheet A12.01

Measuring range 1 to 400 bar

female gas union G 1/4

Measuring range600 to 1000 bar

250C type female adaptor(Autoclave Engineers)

Electrical connection

Top view ofadaptator base

Copper sealHexagon nut22 across flats

Drain

Hexagon nut22 across flats

Cable (2m) + glandOther pressure ports (see below)

Measuring range (M.R.) 1 1.6 2.5 4 6 10 16 25 40 60** 100** 160** 250** 400** 600** 1000**

Max. measurement range 1.2 1.92 3 4.8 7.2 12 19.2 30 48 72 120 192 300 480 660 1200

Max. overrange 2 3.2 5 8 12 20 32 50 80 120 200 320 500 800 1200 1200

Burst pressure 60 70 80 100 120 180 250 350 400 500 800 1000 1500 1800 3000 3000

* Ø 10 x 8, L = 50 mm

** Absolute pressure only

EFO

A + Supply

B + Measurement

C - Measurement

D - Supply

E N.C.

F N.C.

L=65 L=65

G1/4 250C M 14 x 1.5 M 18 x 1.5 M 10 x 1 M 14 x 1.5 G1/2 Smooth* female female male+female male male female male s.s. tube cone 60°

Range (bar) 400 600/1000 400 400 400 400 400 100

Seal copper metal/metal copper 22 x 18.3 x 1.5 8 x 4.2 x 1.5 18 x 14.3 x 1.5 per standard welding 18 x 14.3 x 1.5 18 x 14.3 x 1.5 on tube

L max. 65 90 105 110 105 90 107 -

Dimensions (mm), electrical connections

Options, measuring ranges

Selection table (bar)

Model 1´...3´ digitStandard

Output signal 4´ digitLow level

Hydraulic connection 5´ digitM14 x 150 male (≤ 400 bar)M18 x 150 male (≤ 400 bar)7/16" 20 UNF-3A (≤ 400 bar)G 1/4 H (≤ 400 bar)M14 x 150 female (≤ 400 bar)9/16" 18 UNF-2B (600 and 1000 bar)Tube OD 10 x ID 8, L = 50 ; ≤ 100 bar)G 1/2 (≤ 400 bar)M10 x 100 male (≤ 400 bar)

Pressure range 6´...8´ digitSee codes in table

Pressure type 9´ digitAbsoluteGauge

EF01 x xxxx

EF0

1

A W C R R T X 3 7

xxx

A R

Ordering Details - EF0

B15B16B18B19B20B22B24B26B27B29B31B33B35B38B39B41

code Rangebar

0 + 1 A R 0 + 1.6 A R 0 + 2.5 A R 0 + 4 A R 0 + 6 A R 0 + 10 A R 0 + 16 A R 0 + 25 A R 0 + 40 A R 0 + 60** A 0 + 100** A 0 + 160** A 0 + 250** A 0 + 400** A 0 + 600** A 0 + 1000** A

** Absolute pressure only

UK/

2002

-10

Thi

s da

ta s

heet

may

onl

y be

repr

oduc

ed in

full

Page 95: A1 Electronic Pressure

Data sheet A12.02Design and specifications subject to change without notice

Technical Data (20°C)

EG51-E101-E111-E801-EY81-EMD1 Pressure transducers

EMD1: The combinaison of bonded foil stain gauges to a quasi flush dia-phragm eliminates friction phenomena, and results in high life cycle, high frequency response, infinite resolution.

EG51: This high pressure transducer has been specially designed to withstand severe industrial applications, where ruggedness is an essential criterium. Its monolithic stainless steel body is equipped with bonded foil metallic strain gages. The high pressure tightness is achieved by metal to metal conic gauges contact.

E101/E111: These pressure transducers are based on a TRANSBAR® sen-sitive element, with ceramic membrane, temperature compensated (E111). They are compatible with the most corrosive fluids.

E801/EY81: A stainless steel monolithic proof body, a cable output on over-moulded cover ensures a resiliency allowing to use them in an industrial environment.

Flush diaphragm (EMD1)All stainless steel (EMD1-EG51-E801/EY81)Bonded foil strain gauges (EMD1)Small size (EMD1)Ceramic TRANSBAR® sensing element (E101/E111)Intrinsically safe version (EY81), approval EEx ia IIc T6

EMD1Rated range 0...10 bar to 0...500 barGlobal error ±0.25% F.S.Signal output 2 mV/V ± 20%Normal power supply 12 VdcWetted parts 1.4542 (17.4 PH)Operating temperature -30...+100°CThermal zero drift ±0.02% F.S./°C (+10...+55°C)Hydraulic connection M18 x 1.5Dead volume 0.1 cm3

EG51Rated range 0...500 bar to 0...5000 barGlobal error ±0.5% F.S.Signal output 10 mV nominalNormal power supply 10 VdcWetted parts 1.4418Operating temperature -40...+80°C

Zero thermal drift ≤ 3% F.S./°C (+10...+55°C)Hydraulic connection M20 x 1.5 up to 2500 bar M16 x 1.5 for 5000 barProtection index IP 64

E101Rated range 0...0.5 bar to 0...400 barPower supply 10 V nominalSignal output 20 to 55 mV up on M.R.Operating temperature -25...+85°CFluid temperature -25...+100°CProtection index IP 66Global error 0.4% F.S.Thermal drift ≤ 2.5%(from -10...+55°C)Wetted parts Stainless steel 1.4404 (316L)le fluide

E111Rated range 0...0.5 bar to 400 barPower supply 10 V Signal output 10 to 40 mV up on M.R.Operating temperature -25...+85°CFluid temperature -25...+100°CProtection index IP 66Global error 0.4% F.S.Thermal drift ≤ 2%(from -10...+55°C)Wetted parts ceramic, viton® o'ring

E801/EY81Rated range 0...2 bar to 500 barPower supply nominal 10 VSignal output 100 mV ± 1%Operating temperature -20...+80°CFluid temperature -20...+80°CProtection index IP 66Global error 0.3% F.S.Thermal drift ≤ 2%(from -10...+55°C)Wetted parts 1.4418

Viton® is registered trademarks of DuPont Dow Elastomers

Page 96: A1 Electronic Pressure

Design and specifications subject to change without noticeData sheet A12.02

EG51 : optional, adaptator for tube 9.53 x 3.2 or 6.35 x 1.6

EMD1

E801 / EY81 EG51

E101 / E111

Raccord standard acierà olive pour tube ø 6 mm

+ supply Red or 1 Red or A - supply Blue or 3 Green or D + measur. Yellow or 4 Yellow or B - measur. White or 2 White or C

E101-E111-EG51E801 - EY81 EMD1

CONNECTIONSkg

0.250 kg

kg

0.230 kgkg

0.260 kg

kg

0.075 kg

6

Model 1´ digitElectronic

Type 2´...3´ digitE101E111E801EY81EG51EMD1

Signal ouput 4´ digitmV

Hydraulic connection 5´...6´ digitG 1/2 (E101 / E111 / E801)1/2 NPT (E101 / E111)Compression filling with olive for tube Ø 6 mm (E801 / EY81)Female M20 x 1.5 (≤ 2500 bar) (EG51)Female M16 x 1.5 (5000 bar) (EG51)M18 x 1.5 (EMD1)

Pressure range 7´... 9 digitSee codes in tables

Pressure type 10´ digitAbsoluteGauge

Exx1 xx xxxx

E

10 11 80 Y8 G5 MD

1

03 06 Y0 U0 V0 W0

xxx

A R

Dimensions (mm), connections

Ordering Détails - EG51/E101/E111/E801/EY81/EMD1

B99 0.5 (2)

B15 1 (2)

B18 2.5 (2) (3)

B98 5 (2) (3)

B22 10 (2) (3) (4)

B25 20 (2) (3) (4)

B28 50 (2) (3) (4)

B31 100 (2) (3) (4)

B34 200 (2) (3) (4)

B38 400 (2)

B97 500 (3) (4)

B41 1000 (1)

B96 2500 (1)

B46 5000 (1)

Rangebarcode

(1) EG51 (2) E101 / E111(3) E801 / EY81 (4) EMD1

cable length

gland

screen

according to DIN 16288

Red : + supply

Blue : - supply

Yellow : + measurement

White : - measurement

Compression fitting witholive for tube Ø6 mm

length : 109 socked included

2 flats (27 on flats)

length : 133 plug included

UK/

2002

-10

Thi

s da

ta s

heet

may

onl

y be

repr

oduc

ed in

full

Page 97: A1 Electronic Pressure

Data sheet A12.20Design and specifications subject to change without notice

The TRANSBAR® technology is a spin off of the «thick film technology» used worldwide to produce so called «hybrid electronic circuits».

Patterns of conductive and resistive pasts, or «inks», are deposited on a substrate, generally ceramics, using screen printing techniques.

The uniqueness of the «TRANSBAR®» technology is to use the piezoresistive charac-teristics of specific resistive inks, i.e. the fact that their resistance values vary when submitted to dimensional changes.

These resistors, called strain gauges, judiciously positionned on the deformable structure (diaphragm), are connected together in a four arms Wheatstone bridge configuration.

A regulated voltage source is connected to one diagonal of the bridge. A pressure applied to the diaphragm will deform it and therefore unbalance the bridge, resulting in an electrical signal, on the other diagonal of the bridge, proportional to the applied pressure.

EK (CS) : Open bridge, unbalanced. Bridge impedance :15 k +30%ED (CA) : Closed bridge, balanced. The integrated bridge balancing circuitry eliminates

possible induced parasites due to connections to an external circuit.

EP (CP) : Closed bridge, balanced . Interchangeability : output signal trimmed to ±1%ER (CTi) : Closed bridge, balanced . Thermal drifts compensation : zero and output signal.ET (CT) : Closed bridge, balanced . Thermal drifts compensation : zero and output signal . Interchangeability .

Other models, EC-EL with high level output signal, 0-10 V, or 0-5 V, or 4-20 mA: consult us.

This low level signal, some mV., will have to be amplified to a suitable level to be connected to a display, controller, recorder, PLC or whatever required peripheric equipment.

Constructed entirely of ceramics (Al203, 96 %), comparable to a cristal, these sensors have a quasi perfect mechanical behaviour : good linearity, low hysteresis. They can withstand tens of millions of cycles. Chemically inert, ceramics accepts most industrial media, even aggressive ones.

Their simple geometry allows their easy integration in OEM’s mechanical structures.

The field of their applications is very wide, from basic research to general industry.

Models

EK-ED-EP-ER-ET-EC-EL Pressure Sensors

Measurement of gauge or absolute pressureFrom 250 mbar to 600 bar full scaleCorrosion resistantExcellent long term stabilityLow cost - excellent performances / price ratio

Sectionned wiew

Electrical connections

EK11 / 21(CS1 /2)

ED-EP 11 / 21(CA - CP 1 / 2)

ER-ET 11 / 21(CTi - CT 1 / 2)

ED71 (CA7)

Soldered contacts

Screen printed gauges

Ceramic diaphragm

1 + Exc.

4 - Exc.3 - Signal

2

5+ Signal

1 + Exc.

4 - Exc.3 - Signal

5 + Signal

1 + Exc.

4 - Exc.2 - Signal

3 + Signal

+ Supply

- Supply

+ Supply

- Supply

+ Supply

- Supply

Page 98: A1 Electronic Pressure

Design and specifications subject to change without noticeData sheet A12.20 Data sheet A12.20

Design and specifications subject to change without noticewww.bourdon-haenni.com

Page 3

SERIE 1 - Ø 42 mm - Low pressure ranges

SERIE 2 - Ø 34 mm - Low, medium and high pressure ranges

Technical Data (20°C)

MODELS SPECIFICATIONS EK11 - ED11 - EP11 - ER11 - ET11RANGE IDENTIFICATION : RB (1) RC (1) RD RE RGRATED RANGE (R.R.) : (bar) 0.2 0.5 0.75 1.5 2 (≅ psi) 2.9 7.25 10.9 21.75 29 Max. admissible pressure, without derating of specs : (bar) 0.22 0.55 0.83 1.65 2.2Burst pressure : (bar) ≥ 0.4 ≥ 1 ≥ 1.5 ≥ 3 ≥ 4OUTPUT SIGNAL AT RATED RANGE: (2) (mV) EK11 (±30%) 24 47 45 67 54 ED11 (±30%) 22 45 42 63 50 EP11 (±1%) 18 35 35 45 40 ER11 (±30%) 20 40 38 55 45 ET11 (±1%) 15 30 30 40 30GLOBAL ERROR (max.) : (% R.R.) 1 0.4 0.4 0.4 0.4(non linearity + hysteresis + repeatability)

DIMENSIONS See fig. 1

(1) Gauge pressure only.

SPECIFICATIONS : ALL MODELS EK11 ED11 EP11 ER11 ET11EXCITATION VOLTAGE : Nominal : (Volt) 10 10 10 10 (3) 10 (3)Maximum : (Volt) 30 30 30 10 (3) 10 (3)

BRIDGE IMPEDANCE Input : (kOhm) 15 ≥ 6 ≥ 6 ≥ 6 ≥ 6Ouput : (kOhm) 15 15 10 15 10

TEMPERATURE LIMITS : Operating : (°C) -55 to +125 -55 to +125 -55 to +125 -55 to +125 -55 to +125 Compensated : (°C) n.a. n.a. n.a. -10 to +55 -10 to +55

THERMAL DRIFTS : (2) Zero : (µV / °C) ≤ ±30 ≤ ±30 ≤ ±30 ≤ ±6 ≤ ±6Output signal : (% / °C) -0.04 -0.04 -0.04 ≤ ± 0.01 ≤ ± 0.01

LONG TERM ZERO DRIFT : (% R.R. / year) ≤ ± 0.2 (non cumulative)

INITIAL ZERO UNBALANCE (2) (mV) ≤ ± 500 ≤ ± 2 ≤ ± 2 ≤ ± 1 ≤ ± 1

(2) Under nominal excitation voltage : 10 V (3) 5 V. optional.

MODELS SPECIFICATIONS EK21 - ED21 - EP21 - ER21 - ET21RANGE IDENTIFICATION : MB MC LC LE LI LL LR HR ER* EZ* EP*RATED RANGE : (R.R.) : (bar) 0.6 1 2 5 10 20 50 100 200 350 400 (≅ psi) 9 15 30 75 150 300 750 1500 3000 5250 6000Max. admissible pressure, without derating of specs : (bar) 0.66 1.1 2.2 5.5 11 22 55 110 220 385 440Burst pressure : (bar) ≥1.8 ≥3 ≥6 ≥12 ≥25 ≥50 ≥125 ≥250 ≥450 ≥550 ≥600OUTPUT SIGNAL AT RATED RANGE : (2) (mV) EK21 (±30%) 27 35 51 65 70 70 70 70 65 47 35 ED21 (±30%) 25 33 47 60 65 65 65 65 60 45 30 EP21 (±1%) 20 27 40 50 50 50 50 50 50 35 20 ER21 (±30%) 24 27 37 48 52 52 52 52 48 36 24 ET21 (±1%) 18 20 27 40 40 40 40 40 40 20 15GLOBAL ERROR (max.) (% R.R.) 0.8 0.4 0.4 0.4 0.3 0.3 0.2 0.2 0.2 0.4 0.4(non linearity + hysteresis + repeatability)

DIMENSIONS See fig. 2

Models with* : absolute pressure only.

SPECIFICATIONS : ALL MODELS EK21 ED21 EP21 ER21 ET21EXCITATION VOLTAGE : Nominal : (Volt) 10 10 10 10 (3) 10 (3)Maximum : (Volt) 30 30 30 10 (3) 10 (3)

BRIDGE IMPEDANCE : Input : (kOhm) 15 ≥ 6 ≥ 6 ≥ 6 ≥ 6Ouput : (kOhm) 15 15 10 15 10

TEMPERATURE LIMITS : Operating : (°C) -55 to +125 -55 to +125 -55 to +125 -55 to +125 -55 to +125 Compensated : (°C) n.a. n.a. n.a. -10 to +55 -10 to +55

THERMAL DRIFTS : (2) Zero : (µV / °C) ≤ ±30 ≤ ±30 ≤ ±30 ≤ ±6 ≤ ±6Ouput signal : (% / °C) -0.04 -0.04 -0.04 ≤ ± 0.01 ≤ ± 0.01

LONG TERM ZERO DRIFT : (% R.R. / year) ≤ ± 0.2 (non cumulative)

INITIAL BRIDGE UNBALANCE : (2) (mV) ≤ ± 500 ≤ ± 2 ≤ ± 2 ≤ ± 1 ≤ ± 1

(2) Under nominal excitation voltage 10 V (3) 5 V optional.

Page 99: A1 Electronic Pressure

Design and specifications subject to change without noticeData sheet A12.20www.bourdon-haenni.com

Page 2Data sheet A12.20

Design and specifications subject to change without notice

Model e : mm identification ± 1 %

RB 5.30 RC 5.35 RD 5.40 RE 5.45 RG 5.55

Model e : mm Identification ± 1 %

MB 6.30 MC LC 6.35 LE 6.45 LI 6.625 LL 6.85 LR HR ER 7.30 EZ 8.05 EP 8.55

Figure 1

Series 1

Figure 2

Series 2

Figure 3

Tightening force loading area (ø 40)

Ventilation hole (gaugepressure measurement)

Range identificationTightening force loading area (ø 30)

Connecting pads2.54 mm pitch

Ventilation hole (gaugepressure measurement)

Option : ZITEX humidity protector (gauge pressuremeasurement only)

Tightening force loading area (ø 15)

Range identification

Connecting pads2.54 mm pitch Option : ZITEX humidity protector

(gauge pressure measurement only)

e

e

Model e : mm Identification ± 1 %

FA 6.25 FB DB 6.30 FE DE 6.45 DG CG 6.55 DL CL 6.85 CQ 7.05 CR 7.30 CU 7.65 CZ 7.82

Series 7

Connecting pads2.54 mm pitch

1 Excit.2 Signal3 Signal4 Excit Option : ZITEX humidity protector

(gauge pressure measurement only)

Ventilation hole (gaugepressure measurement)

SERIE 7 - Ø 18 mm - Low, medium and high pressure ranges

Technical Data (20°C)

Dimensions

SPECIFICATIONS ED71RANGE IDENTIFICATION : FA FB DB FE DE DG CG DL CL CQ CR CU CZ RATED RANGE : (R.R.) (bar) 2 4 6 10 16 25 40 60 100 160 250 400 600 (≅ psi) 30 60 90 150 250 350 600 900 1500 2500 4000 6000 -Max. admissible pressure, without derating of specs : (bar) 5 8 12 20 32 50 80 120 200 320 500 800 800Burst pressure : ≥ (bar) 7 12 18 30 48 75 120 180 300 480 600 - 1000OUTPUT SIGNAL AT R.R. : (1) ±30% (mV) 20 20 20 20 22 22 25 22 25 27 25 30 25

GLOBAL ERROR : (% R.R.) ≤ 0.4 ≤ 0.6(non linearity + hysteresis + repeatability)EXCITATION Nominal : (Volt) 10Maximum : (Volt) 20BRIDGE IMPEDANCE Input : (kOhm) Closed bridge : ≥ 6Output : (kOhm) ≥ 6TEMPERATURE LIMITS Operating : (°C) -55 to +125Compensated : (°C) n.a. THERMAL DRIFTS Zero : (µV / °C) ≤ ±30 Output signal : (% / °C) ± 0.01

LONG TERM ZERO DRIFT : (% R.R. / year) ≤ ± 0.2 (non cumulative)

INITIAL ZERO UNBALANCE (1) (mV) ≤ 2

DIMENSIONS See fig. 3

(1) Under nominal excitation voltage : 10 V

Page 100: A1 Electronic Pressure

Design and specifications subject to change without noticeData sheet A12.20

Particular technical specificationsZitex humidity protector (gauge pressure models only)Polyester flat cable, 5 wires, 50 mm soldered on sensors serie 1 or 2Kapton flat cable, 4 wires, 25 mm. Standard for ED71 (soldered).Flexible single wires, soldered on sensor, length to be specifiedAll other options : please consult us.

Above described pressure sensors address OEM users, taking in charge the electronic conditioning of the sensor (excitation, signal amplification) depending upon their actual needs.

For those who would not have such capacities, or for whom, the annual requirement would not allow a satisfying playback on the cost of develop-ment of such electronic circuitry, BOURDON-HAENNI can supply sensors associated with p.c. boards usually fitted in transmitters, delivering a normalised high level output signal for the rated range : 4-20 mA, 1-5 V, 0-10V, directly usable by peripheric equipments as : displays, recorders, controllers, P.L.C.s, etc.

Be careful : Max. operating temperature range is limited to 70°C for absolute pressure versions.

Options

Model 1´ digitPressure sensors

Type 2´...4´ digitSerie 1 - Ø 42 mm

Serie 2 - Ø 34 mm

Serie 7 - Ø 18 mm

Pressure range 5´...6´ digitSee codes in tables

Pressure type 7´ digitAbsoluteGauge

Exxx xx x

E

K11 D11 P11 R11 T11 K21 D21 P21 R21 T21 D71

xx

A R

Pressure sensors, high level output signal models EC - EL

Ordering Details - EK-ED-EP-ER-ET

FAFBDBFEDEDGCGDLCLCQCRCUCZ

RBRCRDRERG

code Range bar

0.2 – R 0.5 – R 0.75 A R 1.5 A R 2 A R

MBMCLCLELILLLRHREREZEP

code Range bar

0.6 A R 1 A R 2 A R 5 A R 10 A R 20 A R 50 A R 100 A R 200 A – 350 A – 400 A –

code Range bar

2 A R 4 A R 6 A R 10 A R 16 A R 25 A R 40 A R 60 A R 100 A R 160 A R 250 A R 400 A R 600 A R

Serie 1 - Ø 42 mm

Serie 2 - Ø 34 mm

Serie 7 - Ø 18 mm

UK/

2002

-10

Thi

s da

ta s

heet

may

onl

y be

repr

oduc

ed in

full

Page 101: A1 Electronic Pressure

Design and specifications subject to change without noticeData sheet A11.02

These pressure transmitters with a stainless steel housing use a very high stability capacitive ceramic sensor to give a rugged and highly reliable product.

They are particularly suited for measuring low pressures in a variety of industrial applications and are compatible with the harshest of process fluids. Applications include : control of process fluids, continuous pressure monitoring and OEM applications.

Calibration of sensor with certificate : Q1060

Additional length of cable

Other measurement ranges in case of high over pressure : please refer to us

Capacitive ceramic sensor

Measurement of pressure and vacuum; absolute or gauge pressure

Measurement ranges: from -100...+100 mbar to 0...+600 mbar

Extremely resistant to over pressure

Analogue output 4-20 mA, by DIN 43650 connector (IP65) or cable output (IP68) (option)

Transmitter in stainless steel (1.4401/AISI 316)

Conforms to European CE Directive (89/336/CEE)

Technical Data (20°C)

EN113 Low pressure transmitters

Measurement range -100...100 mbar to -1...9 bar 0...25 mbar to 0...600 mbar

Output signal 4...20 mA

Supply voltage 11...32 Vdc

Insulation > 100 MΩ at 500 Vdc

Maximum input current 50 mA

Load impedance Rc = (Vsupply - 11V) / 20 mA

CE -conformity Standards EN50082-1 and 2 (immunity) Standards EN50081-1 and 2 (emission) Cabling : screened cable, earthing terminal connected to case

Pressure standards 97/23/CE

Global error (linearity, hysteresis and repeatability) by reference to BFSL Max.: ±0.2% of F.S.

Operating temperature Ambient (Ta) -25...+85°C Fluid -25...+100°C (Ta ≤ 50°C)

Storage temperature -40...+85°C

Compensated temperature range (zero and sensitivity) -10...+55°C

Zero thermal drift All pressures : typically 0.015% of F.S./°C

Thermal variation of sensitivity Max : ±0.01% of F.S./°C

Materials in contact with the fluid Ceramic + stainless steel 1.4401 (AISI 316) + FKM Viton® (standard)

Connections Electrical: DIN 43650 connector (standard) Option : cable output (5 m of cable)

Pressure: G1/2

Degree of protection IP65 (DIN connector)(EN 60529) IP68 (cable output)

Typical response time ≤ 100 ms

Vibrations resistance ±1.6 mm (2 - 25 Hz), 4 g (25 - 100 Hz)(IEC 68-2-6)

Zero adjustment ±5% of F.S.

Options

Uncoded (have to be listed after the code number)

Page 102: A1 Electronic Pressure

Design and specifications subject to change without noticeData sheet A11.02

Dimensions (mm) - connections

Pressure ranges

Ordering Details - EN113

UK/

09-2

002

Thi

s da

ta s

heet

may

onl

y be

repr

oduc

ed in

full.

Cable output 4-20 mA red + supply

black – supply

ground

DIN connector

4-20 mA 1 + supply 2 – supply

3 not connected ground

Standard version(connector output)

Option(cable output)

Pressurerange

vacuum and pressure — — — — — -100 +100 mbar — -200 +200 mbar — -1 +1 bar -1+3 bar -1 +9 bar

pressure 0 +25 mbar 0 +40 mbar 0 +100 mbar 0 +160 mbar 0 +200 mbar — 0 +250 mbar 0+400 mbar 0+600 mbar — — —

Max. permissible pressure 4 bar 4 bar 4 bar 6 bar 6 bar 4 bar 6 bar 6 bar 10 bar 6 bar 25 bar 40 bar

N2HN3MN05N06N08N09N93N10N11N12

code measurement range in mbar.

Vacuum and pressure

-1 + 1 - R -1 + 3 - R -1 + 9 - R

code measurement range in bar.

Vacuum and pressure

-100 + 100 - R -200 + 200 - R 0 + 25 - R 0 + 40 - R 0 + 100 - R 0 + 160 - R 0 + 200 A R 0 + 250 A R 0 + 400 A R 0 + 600 A R

B73B76B79

Model 1´...4´ digitLow pressure Output signal 5´ digit

4...20 mA

Hydraulic connection 6´...7´ digitG 1/4G 1/2 standard1/2 NPT Sensor seal 8´ digit

NBR (Nitrile)EPDMFKM (Viton®) standard Pressure range 9´...11´ digit

See codes in table Pressure mode 12´ digit

AbsoluteGauge

Viton® is registered trademark of DuPont Dow Elastomers

EN113 xx x xxx x

EN11 3

02 03 06

3 5 9

xxx

A R

Page 103: A1 Electronic Pressure

PM 050Hygienic process weld-in sleeve

The hygienic process weld-in sleeve PM 050 is the process sleeve for the hygienic range. By means of the metallic or PEEK sealing cone in accordance to EHEDG a hygiene standard installation is possible. It's used in combination with the process pressure sensor PSC 050 and the inductive conductivity sensor ISL 050. Application possibilities are in all hygienic product ranges (drinks, beer, dairy products, pharmacy etc.).

hygiene standard installation (EHEDG, FDA) defined position of the cable gland or of the M12 plug metallic sealing system no-problem weld-in

Product Information

Product Description

NoticeNoticeNoticeNotice

Technical DataTechnical DataTechnical DataTechnical Data

Material stainless steel V4A 1.4571Thread system hygienic G1"hFitting weld-inNominal diameter Ø 50 mm x 23 mmSealing system metallic; PEEKOperating pressure max. 16 bar

211201 FE

Page 104: A1 Electronic Pressure

Order code

PM 050

Wiring Diagram

Order Code

Dimensional Drawing

PM 050 Hygienic process weld-in sleeve €

211201 FE

Page 105: A1 Electronic Pressure

Capacitice Pressure Sensor

The front flush ceramic pressure sensor PSC 050 with a stainless steel connecting head is used when there are high hygienic demands (e. g. in breweries, dairies, in the drinking and pharmaceutical industry). The applications for the PSC 050 are tank level measurement utilizing the hydrostatic principles and also the relative and absolute pressure measurement.The front flush ceramic sensor is ideal for applications in corrosive and abrasive media. The hygienic installation is guaranteed by using the hygienic process weld-in sleeve PM 050. Due to its high temperature resistance (130 °C), the PSC 050 is well suitable for CIP and sterilization processes.

• Measuring cell is oil-free, front flush and made of ceramic• Compact design in stainless steel• High overload resistance• Best resistance against corrosion and abrasion• CIP and SIP capable• Cable gland has defined position• Hygienic adapter sleeves for other process connections• Turn-Down 1:4

Product Information

Product Description

NoticeNoticeNoticeNotice

Technical DataTechnical DataTechnical DataTechnical Data

PSC 050

Connecting head stainless steel V2A 1.4305; Ø 55 mmElectrical connection cable gland M16; M12 plugProcess connection thread adapter G 1"; sleeve PM 050Membrane ceramic AL2O3Type of protection IP 67Pressure range 0,2 / 0,4 / 1,0 / 2,0 / 4,0 / 10 / 20 bar rel.Overload resistance 10 timesTemperature range −20 °C...+130 °C (140 °C < 1 h)Output 4...20 mA current loopAccuracy ≤ ±0,1 % of full scaleTemperature drift ≤ ±0,005 % / KAuxiliary voltage 14...30 V DC

261101 FE

Page 106: A1 Electronic Pressure

Measuring range

Electrical connection

Display

PSC 050

Wiring Diagram

Order Code

Accessories

Dimensional Drawing

PM 050

1 0...0,2 bar 2 0...0,4 bar 3 0...1,0 bar 4 0...2,0 bar 5 0...4,0 bar 6 0...10 bar 7 0...20 bar

1 cable gland M16 2 plug M12

Hygienic process weld-in sleeve

261101 FE

Page 107: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.10

X910 1/2 NPT conduit fitting with wires output

Measurement of vacuum, absolute or gauge pressureTRANSBAR® ceramic technology (X910)Thin film technology (X510)Zero adjustment as standard (±10% of range)Modularity of hydraulic connectionsLCIE EEx d IIC T5/T6 CENELEC, CSA, CSA US, FM approvalsConforms to European EMC Directive, CE marked

X910 internal terminal stripwith cable gland

Technical Data (20°C)

X910-X510 Explosion-proof pressure transmitter

Measurement range X910 0...25 mbar to 0...400 bar compound, gauge pressure (A,G) X510 0...60 bar to 0...1800 bar pressure (A,G)

Output signal X912-X512: 0...10 Vdc. X913-X513: 4...20 mA (except -1...0 bar where -1 = 20 mA, 0 = 4 mA) X914-X514: 1...5 Vdc. X916-X516: 0...20 mA

Supply voltage X912-X512: 14...40 Vdc X913, X914-X513, X514: 11...40 Vdc.

X916-X516: 8...40 Vdc Option Low voltage: 8...32 Vdc (X913,X914-X513,X514)

Insulation > 100 MΩ at 250 Vdc

Maximum input current X912, X914-X912, X914: 6 mA X916-X516: < 25 mA

Load impedance (+M / –M) X912-X512: ≥ 2.5 k Ω X914-X514: ≥ 1 k Ω X913-X513: RΩ ≤ (Usupply-11)/0.02 X913-X513: RΩ ≤ (Usupply-8)/0.02 (low voltage option ) X916-X516: RΩ ≤ (Usupply-6)/0.02

Global error (linearity, hysteresis and repeatability) by reference to BFSL X910: Typically: ±0.2% of F.S. / Max.: ±0.3%F.S.

For P ≤ 60 mbar: Typically: ±0.6% of F.S. / Max.: ±1%F.S. X510: Typically: ±0.2% of F.S. / Max.: ±0.3%F.S.

Operating temperature Ambient (Ta) X910-X510 -25...+40°C (T6 approval) -25...+70°C (T5 approval) Fluid -25...+100°C (Ta ≤ 50°C)

Storage temperature -40...+85°C

Compensated temperature range (zero and sensitivity) -10...+55°C. Option: -10...+70°C

Zero thermal drift ±0.025% FS/°C max. (except P 1 bar : ±0.06% F.S./°C) Option ±0.015% FS/°C max. (except P 1 bar : ±0.025% F.S./°C)

Span thermal drift X910: Typically: ±0.01% /°C max. : ±0.015% /°C X510: Typically: ±0.04% /°C option : ±0.01% /°C

Wetted parts X910: Ceramic + 1.4404 (316L) stainless steel + NBR seal for P 250 mbar and FKM seal for P < 250 mbarX510: 17-4 PH stainless steel + 1.4404 (316L) stainless steel

Standard connections Electrical: internal terminal strip with cable gland 1/2 NPT conduit fitting with wires output (length 1.5 m) Pressure: G 1/2, 1/2 NPT (other : contact us) Mounting on chemical seals available

CE -conformity Standards EN50082-1 and -2 (immunity) Standards EN50081-1 et -2 (emission) with

sreened cable, screen connected ar both ends Pressure standards 97/23/CE

Protection rating (EN 60529) IP65

Vibration resistance (IEC 68-2-6) 1.5 mm (10 - 55 Hz), 20 g (55 Hz - 2 kHz)

Shock resistance (IEC 68-2-32) 25 falls from 1 m on concrete ground

The X910 and X510 pressure transmitters allow pressure measurements on most corrosive fluids, in hazardous areas.

They are available in a G 1/2 or 1/2 NPT pressure port to be used on low viscosity fluids, or mounted on chemical seals (option) well suited for appli-cation on viscous and cristallizing fluids.

Two electrical outputs are available : internal terminal strip with cable gland or 1/2 NPT conduit fitting with wires output.

Page 108: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.10

Design and specifications subject to change without notice

Data sheet A11.10www.bourdon-haenni.com

Page 3

1/2 NPT

27

23

139

Ø 65

Ø 37,7

X910 for P ≥ 1 barinternal terminal strip with cable gland

Blocking screwCHC M3

Second optional input with top

Access to adjustmentsCHC 1/8 NPT

Certified EEx d IIc cable gland.

1/2 NPT standard. option : 3/4 NPT, G1/2, M20x1.5

X910 for P < 1 barinternal terminal strip with cable gland

Ø 49, P < 250 mbar

27

162

Ø 37,7

Ø 41,1

X913

1 : +A2 : - A3 : : Ground

X912-X914-X916

1 : +M2 : - A / - M3 : +A : Ground

Connections

1.500 1.600kg kg

Dimensions (mm), connections

Page 109: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.10www.bourdon-haenni.com

Page 2 Design and specifications subject to change without notice

Data sheet A11.10

X910 for P ≥ 1 bar1/2 NPT conduit fitting with wires output

X910 for P < 1 bar1/2 NPT conduit fitting with wires output

X510internal terminal strip with cable gland

X5101/2 NPT conduit fitting with wires output

27

1/2 NPT

110

1/2 NPT

27

Ø 37,7

Ø 49, P < 250 mbar

27

133

Ø 41,1

Ø 37,7

139

23

Ø 65

Ø 37,7

27

1/2 NPT

110

1/2 NPT

27

Ø 37,7

X513

1 : +A2 : - A3 : : Ground

X512-X514-X516

1 : +M2 : - A / - M3 : +A : Ground

Connections

Connections

X512-X514-X516

+M : White- A / - M : Black+A : Red : Green/Yellow

X513

+A: Red- A: Black : Green/Yellow

Connections

X912-X914-X916

+M : White- A / - M : Black+A : Red : Green/Yellow

X913

+A: Red- A: Black : Green/Yellow

3 AWG-22 wireslength 1.5m

0.700

Certified EEx d IIc cable gland.

1/2 NPT standard. option : 3/4 NPT, G1/2, M20x1.5

1.500

0.600

0.600

kg kg

kg kg

Page 110: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.10

DegreasedLightning protectionLow supply voltage (see specifications on page 1)Compensated temperature range (- 10...+ 70°C)Zero thermal drift: ±0.015% of range/°C max.Span adjustment ±10% of rangeSpan adjustment ±50% of range for 0.25 < P < 1600 barCalibration of sensor with certificate: Q1060Other hydraulic connectionsAdditional length of wiresOther units: kPa (code D), MPa (code E), kg/cm² (code F), psi (code H), mbar (code N)

Options

Model 1´ digitExplosion-proof pressure transmitter

Type 2´...3´ digitCeramic technologyThin film technology

Output signal 4´ digit0...10 Vdc4...20 mA1...5 Vdc0...20 mA

Hydraulic connection 5´...6´ digitG 1/21/2 NPT

Sensor seal 7´ digitNo sensor seal (X510)NBR (nitril) (standard P 250 mbar)FKM (Viton®) (standard P < 250 mbar)

Pressure range 8´...10´ digitSee codes in tables

Pressure type 11´ digitAbsoluteGauge

Electrical connection 12´ digitInternal terminal strip with cable gland 1/2 NPT (specify for other dimension and second input with top)

1/2 NPT conduit fitting with wires output

Viton® is registered trademarks of DuPont Dow Elastomers

Xx1x xxx xxx x x

X

91 51

2 3 4 6

03 06

0 3 9

xxx

A R

1 2

Measuring Ranges (bar)

Ordering Details - X910

Uncoded Options (have to be listed after the code)

X910 Pressure in mbar Pressure in bar

Compound Pressure — — — — — — — — -1+0 -1+0.6 -1+1.5 -1+3 -1+5 -1+9 -1+15 -1+24 -1+39 — — — — —

Pressure 25 40 60 100 160 250 400 600 1 1.6 2.5 4 6 10 16 25 40 60 100 160 250 400

Measurement range 27.5 44 66 110 175 275 440 660 1.1 1.75 2.75 4.4 6.6 11 17.6 27.5 44 66 110 176 275 440

Max. over pressure 110 110 275 500 500 1000 1000 1000 3 3 4 8 12 20 32 50 80 120 200 320 500 600

Burst pressure 200 200 500 1000 1000 2000 2000 2000 6 6 7 12 18 30 48 75 120 180 300 480 600 800

X510 Pressure in bar

Pressure 60 100 160 250 400 600 1000 1600 1800

Measurement range 66 110 176 275 440 660 1100 1760 1980

Max. over pressure 200 200 320 500 800 800 2000 2100 2100

Burst pressure 400 400 640 1000 1600 2500 2500 2500 2500

Range in mbar

N05N06N07N08N09N10N11N12

code

0 + 25 – R x 0 + 40 – R x 0 + 60 – R x 0 + 100 – R x 0 + 160 – R x 0 + 250 A R x 0 + 400 A R x 0 + 600 A R x

X910 X510

B59B72B74B76B77B79B81B82B1LB15B16B18B19B20B22B24B26B27B29B31B33B35B38B39B41B42B1F

code-1 + 0 – R x-1 + 0.6 – R x-1 + 1.5 – R x-1 + 3 – R x-1 + 5 – R x-1 + 9 – R x-1 + 15 – R x-1 + 24 – R x-1 + 39 – R x 0 + 1 A R x 0 + 1.6 A R x 0 + 2.5 A R x 0 + 4 A R x 0 + 6 A R x 0 + 10 A R x 0 + 16 A R x 0 + 25 A R x 0 + 40 A R x 0 + 60 A R x x 0 + 100 A R x x 0 + 160 A R x x 0 + 250 A R x x 0 + 400 A R x x 0 + 600 A R x 0 + 1000 A R x 0 + 1600 A R x 0 + 1800 A R x

Range in bar X910 X510

UK/

2002

-10

Thi

s da

ta s

heet

may

onl

y be

repr

oduc

ed in

full

Page 111: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.11

Measurement of vacuum, absolute or gauge pressure

TRANSBAR® ceramic technology

Zero adjustment as standard (±10% of range)

Welded construction – reinforced product

Modularity of electrical and hydraulic connections

Highly resistant to severe process conditions (≥ 107 pressure cycles)

Marine version (Bureau Veritas ...)

LCIE 02 ATEX 6133X

The Y910 pressure transmitters allows pressure measurements on most cor-rosive fluids, in hazardous areas.

Technical data (20°C)

Y910 Intrinsically Safe Pressure Transmitter

Measurement range From 0...25 mbar to 0...600 bar Compound, gauge or absolute pressure

Output signal Y912: 0...10 Vdc. Y913: 4...20 mA (except -1...0 bar where -1 = 20 mA, 0 = 4 mA)

Y914: 1...5 Vdc. Y916: 0...20 mA

Supply voltage Y912: 14...28 Vdc Y913-Y914: 11...28 Vdc Y916: 8...28 Vdc Option Low voltage: 8...28 Vdc (Y913, Y914)

Power supply electrical parameters device must be: Usupply ≤ 28 Vdc ; I ≤ 120 mA ; P ≤ 0.8 W

See drawings overleaf for more details.

Insulation > 100 MΩ at 500 Vdc

Maximum input current Y912-Y914: 6 mA Y916: < 25 mA

Load impedance (+M / –M) Y912: ≥ 2.5 k Ω Y913: RΩ ≤ (Usupply-11)/0.02 ; Rc min = 200 Ω Y913: RΩ ≤ (Usupply-8)/0.02 (low voltage option) Y916: RΩ ≤ (Usupply-6)/0.02 ; Rc min = 100 Ω

CE Conformity CEM Directive 89/336/CE (EN50082-1 and -2, EN50081-1 and -2) with screened cable, screen connected at both ends.

Pressure Directive 97/23/CE : 3.3 for P < 200 bar and cat 1 for P ≥ 200 bar.

ATEX Directive 94/9/CE (EN50014, EN50020, EN50281-1-1).

Global error (linearity, hysteresis and repeatability) by reference to BFSL Typically: ±0.2% of F.S. / Max.: ±0.3% of F.S. For P ≤ 60 mbar and P= 600 bar: Typically: ±0.6% of F.S. / Max.: ±1% of F.S.

Operating temperature Ambient (Ta) -25...+75°C Ta = +40°C G: T6 D IP65 : T°surface = +80°C Ta = +75°C G: T5 D IP65 : T°surface = +95°C (G = Gas ; D = Dust) Fluid -25...+100°C (Ta ≤ 50°C) depending on class

Storage temperature -40...+85°C

Compensated temperature range (zero and sensitivity) -10...+55°C. Option: -10...+70°C

Zero thermal drift ±0.025% F.S./°C max. (except P ≤ 1 bar: ±0.06% F.S./°C) Option: ±0.015% F.S./°C max. (except P ≤ 1 bar: ±0.025% F.S./°C)

Span thermal drift Typically: ±0.01%/°C / Max.: ±0.015%/°C

Wetted parts Ceramic + stainless steel 1.4404 (316L) + NBR seal (standard) for ranges > 250 mbar and Viton® for ranges ≤ 250 mbar

Standard connections Electrical: DIN 43650 connector Pressure: G1/2 Many options available

Protection rating (EN 60529) Standard: IP65 (DIN connector) Option: IP67 or IP68 (depending on connection)

Typical response time ≤ 3 ms

Vibration resistance (IEC 68-2-6) 1.5 mm (10-55 Hz), 20 g (55 Hz to 2 kHz)

Shock resistance (IEC 68-2-32) 25 falls from 1 m on concrete ground

CE 0081

I M1 G and D EEx ia I

II 1 G and D EEx ia IIC T6 or T5

Hazardous area: Area 0, 1, 2, 20, 21, 22

Page 112: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.11

Design and specifications subject to change without notice

Data sheet A11.11www.bourdon-haenni.com

Page 3

G1/2

20

Ø 41,1

117

98

Ø 49, P < 250 mbar

27

Ø 27

Standard version. P ≥ 1 barDIN 43650 plug

Ø 35

Ø 27

96

67

10

Ø6 ... Ø8

G1/2

20

S

Z

3

2 1

27

Standard version for P < 1 barDIN 43650 plug

Version also used for -1...0 bar and 0...1 bar ranges with ±50% span adjustment option.

Y913

1 : +A2 : - A3 : : Ground

Y912Y914Y916

1 : +M2 : - A / - M3 : +A : Ground

Connections

0.4000.300

Option : Stainless steel surface mounting brackets

Access to adjustments

41.5

BOURDON HAENNI

kg kg

Ø 27

87 [

108]

72 [

93]

10

Ø6,5

27

Option 23Pig tail (length 1.5 m) + PG7 Cable gland

Option 22Pig tail (length 1.5 m)

Connections

0.350 [0.450] 0.350 [0.450]

Y913

+A : White- A : Blue : Ground

Y912-Y914-Y916

+M : Yellow- A / - M : Blue+A : Red : Ground

Option 08DIN 43650C micro plug (8 mm)

10

67 [

98]94

[11

5]

Ø 27

28

Ø4 ... Ø6

3

2 1

27

Connections

Y913

1 : +A2 : - A3 : : Ground

Y912-Y914-Y916

1 : +M2 : - A / - M3 : +A : Ground

0.250 [0.350]

Ø 27

72 [

93]

10

Ø6,5

27

Connections

Y913

+A : White- A : Blue : Ground

Y912-Y914-Y916

+M : Yellow- A / - M : Blue+A : Red : Ground

kg kg kg

Installation instructions

[xx] : dimensions and weight for "P < 1 bar" versions.

Dimensional Drawings (mm) - Mounting Details

Hazardous areaArea: 0, 1, 2, 20, 21, 22

Umax = 28 VdcImax = 120 mAP = 0,8 WCa > Ci + Ccable

La > Li + Lcable

Ci = 30 nF (Y913 - Y916)Ci = 60 nF (Y912 - Y914)

Don’t forget the barrier’s resistors in the determination of Rc1.In area 0 or 20, the loop calcula-tion of the association transmit-ter with safety barrier must be approved by notified organism.

Certified safety barrier

Non hazardous area

Screen

Screen

Supply

Supply

Page 113: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.11www.bourdon-haenni.com

Page 2 Design and specifications subject to change without notice

Data sheet A11.11

Ø6 ... Ø8

Ø 38

107

[128

]

61 [

82]

10

1

2

3

4

5

6

27

Connections

Y912-Y914-Y916

+M : Yellow- A / - M : Blue+A : Red : Ground

Y913

+A: White- A: Blue : Ground

104

[125

]

71,5

[92

,5]

1011

1/2 NPT Ø6,5

27

27

Ø27

Y913

1 : +A2 : - A3 : : Ground

Y912-Y914-Y916

1 : +M2 : - A / - M3 : +A : Ground

Connections

0.350 [0.450] 0.400 [0.500]

Ø 27

10

72 [

93]

89 [

110]

A

B

F E

D

C

27

85 [

106]

43

72 [

93]

10

27

4

1 2

3

Connections

Y912-Y914-Y916

A : +AB : - A / - MC : +MD :E : GroundF :

Y913

A : +AB : C : - AD :E : GroundF :

Connections

Y912-Y914-Y916

1 : +A2 : +M3 : Ground4 : - A / - M

Y913

1 : +A2 : 3 : Ground4 : - A

0.250 [0.350] 0.300 [0.400] 0.400 [0.500]

Connections

Y913

+A : White- A : Blue : Ground

Y912-Y914-Y916

+M : White- A / - M : Blue+A : Red : Ground

1065

[86

]

Ø 6,5

27

kg kg

kg kg kg

Dimensional Drawings (mm) - Mounting Details[xx] : dimensions and weight for "P < 1 bar" versions.

Option 20terminal strip outlet + screwed cap

Option 54Pig tail cable outlet with 1/2 NPT male (length 1.5 m)

1 : Plug2 : Case3 : Seal4 : Connector5 : Nut6 : PG7 Cable gland (horizontal or vertical)

Optional accessory

Option 096 contacts HE302 plug

Option 24M12, 4 contacts plug

Option 27Submersible cable (length 1.5 m)

Cab

le le

ngth

Page 114: A1 Electronic Pressure

Design and specifications subject to change without notice

Data sheet A11.11

Options

Uncoded Options (have to be listed after the code)DegreasedLightning protectionMarine versionLow supply voltage(1)

Compensated temperature range (- 10...+70°C)Zero thermal drift: ±0.015% of range/°C max.Span adjustment ±10% of rangeSpan adjustment ±50% of range (except for ranges ≤ 0...+0.25 bar and 0...+600 bar) Calibration of sensor with certificate: Q1060Thread lockingOther hydraulic connectionsAdditional length of cableStainless steel surface mounting brackets Other units: kPa (code D), MPa (code E), kg/cm² (code F), psi (code H), mbar (code N)Atmospheric pressure measurement (Range: 800...1200 mbar absolute)

Coded Options

Other electrical connections: 08.DIN 43650C micro plug (IP65 (2)) 22.Pig tail (1.5 m) (IP65) 23.Pig tail (1.5 m) + PG7 cable gland (IP65, IP67 (3)) 54.Pig tail cable outlet with 1/2 NPT male (1.5 m) (IP65) 20.Terminal strip outlet + screwed cap (IP65, IP67) 09.6 contacts HE302 plug (IP65) 24.M12, 4 contacts plug (IP65) 27.Submersible cable (IP68 version (4))

Model 1´...3´ digitIntrinsically safe Output signal 4´ digit

0...10 Vdc4...20 mA1...5 Vdc0...20 mA

Hydraulic connection 5´...6´ digitG 1/4G 1/2 standard1/4 NPT1/2 NPT Sensor seal 7´ digit

NBR (Nitril) standardCR (Neoprene) (P ≥ 250 mbar)EPDM (P ≥ 250 mbar)Kalrez® (P ≥ 1 bar)FKM (Viton®) Pressure range 8´...10´ digit

See codes in tables Pressure type 11´ digit

AbsoluteGauge

Kalrez® and Viton® are registered trademarks of DuPont Dow Elastomers

Measuring Ranges

Ordering Details - Y910

(1) see specifications for details / (2) IP65 : water spray / (3) IP67 : temporary immersion /(4) IP68 : prolonged immersion

Y91x xx x xxx x

Y91 2 3 4 6

02 03 05 06

3 4 5 7 9

xxx

A R

Pressure in mbar Pressure in bar

compound pressure — — — — — — — — -1+0 -1+0.6 -1+1.5 -1+3 -1+5 -1+9 -1+15 -1+24 -1+39 — — — — — —

pressure 25 40 60 100 160 250 400 600 1 1.6 2,5 4 6 10 16 25 40 60 100 160 250 400 600

Measurement range 27.5 44 66 110 175 275 440 660 1.1 1.75 2.75 4.4 6.6 11 17.6 27.5 44 66 110 176 275 440 660

Max. over pressure 110 110 275 500 500 1000 1000 1000 3 3 4 8 12 20 32 50 80 120 200 320 500 600 800

Burst pressure 200 200 500 1000 1000 2000 2000 2000 6 6 7 12 18 30 48 75 120 180 300 480 600 800 1000

Range in mbar 0 + 25 – R 0 + 40 – R 0 + 60 – R 0 + 100 – R 0 + 160 – R 0 + 250 A R 0 + 400 A R 0 + 600 A R

code Range in bar. Vacuum pressure

-1 + 0 – R -1 + 0.6 – R -1 + 1.5 – R -1 + 3 – R -1 + 5 – R -1 + 9 – R -1 + 15 – R -1 + 24 – R -1 + 39 – R 0 + 1 A R 0 + 1.6 A R 0 + 2.5 A R 0 + 4 A R 0 + 6 A R 0 + 10 A R 0 + 16 A R 0 + 25 A R 0 + 40 A R 0 + 60 A R 0 + 100 A R 0 + 160 A R 0 + 250 A R 0 + 400 A R 0 + 600 A R

code

B59B72B74B76B77B79B81B82B1LB15B16B18B19B20B22B24B26B27B29B31B33B35B38B39

UK/

09-2

002

Thi

s da

ta s

heet

may

onl

y be

repr

oduc

ed in

full.

N05N06N07N08N09N10N11N12