Tlp. (021) 26646205 - 98883072 Fax.(021) 26646826 Hp.0812 8933605
Design and specifi cations subject to change without notice
Data Sheet A112-3400-1
Description
4...20 mA, 2-wire transmitter,HART® communication
Confi gurable span, unit and damping
Turn down 25:1
Zero point adjustment
2-point calibration
-1(0)...400 bar
Gauge or absolute pressure
400% overpressure safety limit
Hygienic process connections
Demko EEx ia IIC T5/T6, ATEX II 1G
Demko Ex N IIC T5/T6
Barbara Ex ia IIC T5/T6
FlexBar HRT is a loop powered, confi gurable pressure transmitter. FlexBar HRT measures the pressure by means of a polysilicon strain gauge sensor. The electronics are separated from the media by a thin diaphragm and an oil-fi lling. Three different oil fi llings are available including a mineral oil complying with demands from FDA for use in the food and pharmaceutical industries.
The electronics are located in a separate sealed housing giving FlexBar HRT superb resistance to moisture. Cable connection is via gland or plug.
The HART® communication features on-line process calibration/adjustment and transmitter confi guration.
FlexBar HRT is used in food, chemical and petrochemical industries to measure absolute or gauge pressure for machine and hydraulic applications etc.
The wide range of process connections together with the confi gurable facilities make FlexBar HRT the ideal choice for all pressure measuring applications.
Hygienic process connections for a wide range of standards are avail-able for FlexBar HRT with a fl ush diaphragm and G1/2A male nipple. Please refer to the data sheet for FlexBar HRT Accessories.
The FlexView LC-display is optional.
FlexBar HRT Pressure Transmitter
VIRLIE ENGINEERING Co.Mall Mega Glodok Kemayoran Lt.G Blok.D5-1 Jakarta Pusat
Email. [email protected] / [email protected]. www.safety07.com / www.virlie.indonetwork.co.id / virliefujiyama.indonetwork.co.id
Design and specifi cations subject to change without notice
Data Sheet A112-3400-1
Technical Data
InputMeasuring limits See "Ordering Details"
Overpressure 400% of f.r., max. 600 bar(continuously)
OutputSignal span 4...20 mA or 20...4 mA 1
2-wire, HART® communication
Output limits 3.5...23 mA 1
Characteristic Linear or customised withmax. 30 points 1
Accuracy < 0.2% f.r.
Isolation voltage 500 Vac (From housing to 4...20 mA connection)
Resolution 12 bit
Load equation RL < (VCC-6.5)/23 [kOhm]
Display (optional)Please refer to FlexView data sheet
Opto-relayVoltage, standard Max. 230 Vac
Voltage, GL-approved Max. 60 Vac
DC-voltage Max. 50 Vdc
Current, continuously Max. 50 mA
Current, pulse Max. 500 mA
Relay function Set/reset 1
Confi guring limitsSpan 4...100% of full range 1
Zero point 0...96% of full range 1
Auto zero -10...10% of full range 1
CommunicationFlexProgrammer PC-program (Windows)
2-way communication (Refer to data sheet)
HART® protocol HCF standard
Features 1 Read serial numberRead/Change user IDRead/Change confi gurationRead input signal valueRead output signal valueInput signal logging2-point sensor trimCurrent output trim
Power supplyNominal 24 Vdc
Supply voltage 6.5...35 Vdc
Effects caused by changes in power supply:
Zero point 0.005% per V
Measuring range 0.001% per V
Error handlingUp/Down scaling 23 mA/3.5 mA 1
Operational conditionsStorage temperature -40...85°C
Process temperature Standard: -30...120°CCleaning < 135°C for 15 min.Cooling neck: -30...200°C(Filling fl uid DC550)
Ambient temperature -10...70°C
Relative humidity < 98%, condensing
Protection class Plug: IP 65Gland: IP 65 + IP 66
Vibrations Lloyds Register, test 2
Shock test 100g for 10 msec.
Operational condition effectsAmbient temperature infl uence, measured at -10...70°Cand max. span:
Zero point: < 0.05% per 10K
Span: < 0.05% per 10K
Process temperature: < 0.2% per 10K
Cooling neck only: Media temperature (tm) infl uence in thetemperature interval 100...200°C:
G1/2A: 20 mbar + (tm - 100) x 2.0 mbar
DS 722: 20 mbar + (tm - 100) x 0.5 mbar
ISO 2852: 20 mbar + (tm - 100) x 0.5 mbar
3A/DN38: 20 mbar + (tm - 100) x 1.0 mbar
3A/DN76: 20 mbar + (tm - 100) x 0.5 mbar
Varivent: 20 mbar + (tm - 100) x 0.5 mbar
Transitional behaviourSwitch-on time 4 sec.
Sample time 0.5 sec.
Step response time < 1 sec.
Damping, t99 0...60 sec. (2 sec. steps) 1
Long-term drift Typ. 0.1% per year
EMC dataImmunity EN 50082-2
Emission EN 50081-2
Approval (Demko) EEx ia IIC T5/T6, ATEX II 1GApproval (Barbara) Ex ia IIC T5/T6 Supply range 6.5...30 Vdc
Internal inductivity Li < 10 µH
Internal capacity Ci < 1 nF
Barrier data U < 30 Vdc ; I < 0.1 A ; P < 0.75 W
Temperature class T1...T5: -10 < Tamb < 70°CT1...T6: -10 < Tamb < 50°C
Approval (Demko) Ex N IIC T5/T6 Temperature class T1...T5: -10 < Tamb < 70°C
T1...T6: -10 < Tamb < 50°C
Design and specifi cations subject to change without notice
Data Sheet A112-3400-1
The mounting of the pressure sensor ensures fast response time, ex cel lent temperature compensation and high measuring accuracy. All diaphragm weldings are checked with a helium leak-tester.
FlexBar HRT can be confi gured either with a handheld HART® communicator or with the dedicated Bourdon-Haenni FlexProgrammer unit connected to a standard PC.
Unless specifi ed FlexBar HRT is supplied with a standard confi guration:Pressure at 4 mA: Minimum measuring limitPressure at 20 mA: Maximum measuring limitDamping: 0 sec.Device address: 0
Accessories for FlexBar HRT are usually supplied separately and must be assembled by the customer. However, if you prefer the accessories to be assembled from the factory prior to delivery, please order type number 81 26-950.
Having the HART® communication facilities the FlexBar HRT can be operated as a conventional 4...20 mA device, or it can be connected to other HART® devices in a 2-wire HART® network, in one of three connection methods:
Mixed-signal: Please refer to HART® literature
Point-to-point: See „Applications“
Multi-drop: See below
MaterialsHousing: Stainless steel (AISI 304/W1.4301)
Pressure sensor: Polysilicon strain gauge
Fill fl uid: Ondina, Halocarbon or DC550
Wetted parts: Acid-proof stainless steel(AISI 316L/W1.4404) or Hastelloy C
Options: PTFE-tefl on coating (Accofal 2G54)
Other coatings on request
Disposal of product and packingAccording to national laws or by returning to Bourdon-Haenni
Electrical connectionCable entry Gland PG9, PG13.5 or M20
Plug DIN 43650, form BPlug DIN 43650, form A
Approval Germanischer Lloyd (with cable type no. 81 26-940)
Note 1 Confi gurable
Master
12 mA (for 3 slaves) + HART® communication signals
4 mA 4 mA4 mA
Device 1 Device 2 Device 3
In Multi-drop mode up to 15 slaves can be connected to a 2-wire cable. Each device must have a unique device number different from 0. In case that one trans mit ter is given a device number of 0, the system will revert to Mixed-signal mode.
Multi-drop mode:
bar PSI mH2O Pascal kPa MPa
1 14.5 10.197 105 100 0.1
Technical Data
Additional Description
Measuring Units Conversion
Design and specifi cations subject to change without notice
Data Sheet A112-3400-1
Type 4´ digit4...20 mA 4...20 mA with opto-relay 4...20 mA with HART® communication 4...20 mA with HART® communication and opto-relay
Safety 5´ digitStandard version Demko EEx ia IIC T5/T6, ATEX II 1G Demko Ex N IIC T5/T6Barbara Ex ia IIC T5/T6
Cable connection 6´ digit Gland PG13.5 Gland M20 Plug DIN 43650, form B 2 Gland PG9Plug DIN 43650, form A 2 5
Process connection position 7´ digitAt the base At the rear At the base with cooling neck At the rear with cooling neck
Diaphragm surface 8´ digitStandard Covered with Tefl on 3
Oil fi lling 9´ digitOndina (Recommended for food industry applications, max. 120°C) Halocarbon (For Oxygen measuring, max. 120°C) DC550 (Silicone oil for high temperature applications, max. 200°C)
Process connection standard 10´ digitFlush diaphragm, male nipple G1/2A PN400 AISI 316LFlush diaphragm, male nipple G1/2A PN400 Hastelloy C-276DS 722 Rotating female nut DN40 PN16 AISI 316LISO 2852 clamp DN38 PN40 AISI 316LISO 2852 clamp DN51 PN40 AISI 316L3A hygienic connection DN38 PN40 AISI 316L3A hygienic connection DN76 PN40 AISI 316LGEA Tuchenhagen Varivent PN40 AISI 316LSMS 1145 male nipple DN38 PN25 AISI 316LM44 x 1.25 male nipple, pulp and paper version PN16 AISI 316LM44 x 1.25 male nipple, hygienic version PN16 AISI 316Lø43 mm hygienic connection PN16 AISI 316LDIN 11851 Rotating female nut DN40 PN25 AISI 316LDIN 11851 Rotating female nut DN50 PN25 AISI 316LSMS 1145 Rotating female nut DN38 PN25 AISI 316LSMS 1145 Rotating female nut DN51 PN25 AISI 316L1/2“-14 NPT male nipple, ANSI/ASME B1.20.1 PN400 AISI 316L Gauge connection for external seal 4 G1/2A PN16 DIN 16288
Pressure type 11´ digitRelative pressure (bar) Absolute pressure (bar)
Pressure range 12´ digit-0.1...0.4 0...0.4 -0.4...1 0...1 -1.0...2.5 0...2.5 -1.0...6 0...6 -1.0...16 0...16 -1.0...40 0...40 -1.0...100 0...100 -1.0...400 0...400
Ordering Details - FlexBar HRT
816x xxxx xxxx
1 2 3 4
1 2 3 4
1 2 3 4 5
1 2 3 4
1 2
1 2 3
1 2 3 4 5 6 7 8 9 E F G H J K L N S
1 2
1 2 3 4 5 6 7 8
Design and specifi cations subject to change without notice
Data Sheet A112-3400-1
Resistance Power supply FlexBar HRT pressure transmitter > 250 Ohms (or master) with FlexView display (optional)
Handheld HART® communicator, model 275
230 Vac
24 Vdc
4...20 mA
2 Not available with relay
3 P<16 bar. Also for use in food processing (FDA)
4 P<16 bar. This connection has no diaphragm and no oil fi lling. An external fl ange with seal and non-aggressive/non-conductive fi lling fl uid must be mounted.
5 Only available with process connection at the base
Screw terminals:1 & 2: 4...20 mA loop3 & 4: Opto-relay (optional)
LED, lights during auto zero adjustment
Auto Zero push button
1 & 2: Pins for connection of FlexProgrammer
ConnectorDIN 43650 B
Test terminals:A multimeter (Ri < 2 Ohms) can be connected to measure the loop current without breaking the loop.
Ground connector
Ordering Details - Notes
Electrical Connection
3 4
1 2
NoteWhen the handheld HART® communicator is used for confi guration of the FlexBar HRT, the total series resistance in the 4...20 mA loop must exceed 250 Ohms. The confi gurator must hold the device specifi c DDL to be able to address all available HART® features.
+ 1 2 -
Non-Ex-application, Point-to-point
Design and specifi cations subject to change without notice
Data Sheet A112-3400-1
M44 x 1.25 connection with M44 x 1.25 hygienic connection M44 x 1.25 pulp/paper version cut through rotating male nipple mounted in welding part mounted in welding part
128.5
FlexBar HRT G1/2A, with gland Process connection at the base Process connection at the baseProcess connection at the base with plug. Side view with display. FrontviewSide view
Gland PG9, PG13.5 or M20
[mm] FlexView display is optional
ø86
FlexBar HRT G1/2A, with plug Process connection at the rear Cooling neck (integrated). Specify Process connection at the rear With display and plug mounting at the base or at the rear.Side view Front view Add the indicated measure to height
4535
47.5
ø43 mm connection with O-ring sealing ø43 mm connection with O-ring sealing mounted in and DN25 rotating female nut (DIN 11851) welding part and with fl ange (shown without nut)
69.5
40.5
79.5
6.1
20.5
26.4Rotating male nipple
Welding part
Leakhole
O-ring
39.415
84ø65
77.3
ø43.7
ø64
ø11.5 (4 holes)
Tefl on ring
Dimensional Drawings
Design and specifi cations subject to change without notice
Data Sheet A112-3400-1
ø25.3
ø50.5
32
57
ø54
30
[mm]
DS 722 rotating female nut, DN40 3A hygienic, DN38 3A hygienic, DN76
ø17.5
ø2642.5 42.5
161630 30
R6
R6R6
Gauge connection for Male nipple G1/2A ISO 2852 clamp ISO 2852 clamp external seal 6 Flush diaphragm DN38 DN51
ø91
32
57
ø84
ø68
30
12
ø72.3
ø64ø50.5
GEA Tuchenhagen Varivent Male nipple 1/2-14 NPT DIN 11851 rotating female nut
DN 40 ø56 DN 50 ø86.5
31
FlexBar HRT total measure: Housing + (cooling neck) + connection
6 This connection has no diaphragm and no oil fi lling. An external fl ange with seal and non-aggressive/non-conductive fi lling fl uid must be mounted.
SMS 1145 Rotating female nut SMS 1145 Male nipple
DN 38 ø55 DN 51 ø65
30 30
DN 38 ø60 DN 51 ø70
48.5
24
Dimensional Drawings
Notes
Design and specifi cations subject to change without notice
Data Sheet A112-3400-1
GB/
2002
-11-
01
This
dat
a sh
eet m
ay o
nly
be re
prod
uced
in fu
ll.
Zone 0/1 Safe area
4...20 mA 24 Vdc
230 Vac
FlexBar HRT FlexView display Barrier Power Supply (Optional) (Ri > 250 Ohms)
FlexBar HRT is approved by Demko for EEx ia IIC T5/T6 and ATEX II 1G according to the European standards EN 50014 and EN 50020 FlexBar HRT is approved by Barbara for Ex ia IIC T5/T6. FlexBar HRT must be installed in accordance with prevailing guidelines for zone 0 or 1, and a certifi ed, intrinsically safe zener barrier or isolation barrier with the maximum values Umax= 30 Vdc; Imax= 0.1 A ; Pmax= 0.75 W must be used.
5 8
1 2 3 4
Ex-installation, Point-to-point
FlexBar HRT is approved by Demko for Ex N IIC T5/T6 according to BS 6941:1988 for installation in zone 2 without a barrier.
Design and specifi cations subject to change without notice
Data Sheet A112-3400-2
Description
FlexBar HRT with homogenizer connection is designed for this extreme environment and application. There are four available connections.
All wetted parts of the pressure transmitter are produced of acid-proof stainless steel.
The electronics are located in a separate sealed housing giving FlexBar HRT superb resistance to moisture and a high mechanical stability. Cable connections via gland or plug are available.
FlexBar HRT has a confi gurable damping to stabilize the output signal and the read-out during the pulsating pressure coming from the homogenizer.
The HART®communication features remote process control and supervision as well as on-line calibration and adjustment of the transmitter.
The FlexBar HRT for homogenizer is delivered with a FlexView LC-display.
FlexBar HRT for Homogenizer
Pressure transmitter 4...20mA for homogenizer
High mechanical stability, LRS test 2
Pressure ranges 0...400 bar
Temperature range -30...120°C
Acid-proof stainless steel
FlexView LC-display
Design and specifi cations subject to change without notice
Data Sheet A112-3400-2
GB/
2002
-06-
01
This
dat
a sh
eet m
ay o
nly
be re
prod
uced
in fu
ll.
Please refer to FlexBar HRT data sheet.
Technical Data
Type 4´ digit4...20 mA4...20 mA with opto-relay4...20 mA with HART® communication4...20 mA with HART® communication and opto-relay
Cable connection 6´ digitGland PG13.5Gland M20Plug DIN 43650, form BGland PG9Plug DIN 43650, form A
Process connection 10´ digitFlush diaphragm PN400 AISI 316L/W.1.4404Flush diaphragm PN400 AISI 316L/W.1.4404Flush diaphragm PN400 AISI 316L/W.1.4404Flush diaphragm PN400 AISI 316L/W.1.4404
Version A Type number 816x 1x11 1A18 Version B Type number 816x 1x11 1B18
Version C Type number 816x 1x11 1C18 Version D Type number 816x 1x11 1D18
[mm]
80
42.5
27.5
209.45.10
80
19.212.7
0
50
38
20.114.9
0
50
38
20.114.9
0
Not included ø18
ø23.5 ø23.5
ø34.8 ø33.3
28
W x D x H95 x 45 x 28
Type number 81 26-951 for version A 5 pcs. backing ring, PTFE 5 pcs. O-ring, FPM70
Type number 81 26-952 for the versions B, C and D 5 pcs. O-ring, FPM70
ø23 ø23ø34.5ø35.8
G1 1/4ø60
Ordering Details - FlexBar HRT for Homogenizer
816x 1x11 1x18
Dimensional Drawings
1 2 3 4
1 2 3 4 5
A B C D
1
Description
Accessories for FlexBar HRT pressuretransmitter
Clamp rings
Welding parts
Blind plugs
Reductions
Flanges
Adaptors
O-rings
Wall bracket
FlexBar HRT is a loop powered, configurable pressuretransmitter with 4...20 mA output and HART®
communication.
FlexBar HRT is used to measure absolute or gaugepressure.
A wide range of both national and international processconnections make FlexBar HRT the ideal choice forpressure measuring applications in the food, chemicaland petrochemical industries.
FlexBar HRT Accessories
Besides the fixed connections a range of replaceable,hygienic connections are available to mount on theFlexBar HRT model with a flush diaphragm and G1/2Anipple.
This data sheet holds data for accessories such aswelding parts, clamp rings etc. for FlexBar HRT.
The FlexView display is optional - technical data can befound in the specific data sheet.
3400-3
81 26-930Flange, DN25, DIN 2527 for 816x xxxx x6xx
81 26-931Flange, DN40, DIN 2527 for 816x xxxx x6xx
81 26-932Flange, DN50, DIN 2527 for 816x xxxx x6xx
81 26-933Flange, DN80, DIN 2527 for 816x xxxx x6xx
81 26-901Clamp ring, ISO 2852, DN38/PN64
81 26-902Clamp ring, ISO 2852, DN51/PN10
81 26-903Clamp ring, ISO 2852, DN51/PN64
81 26-904Clamp ring for flange, DIN 2527, DN38/PN64(incl. spec. nut)
81 26-905Clamp ring for flange, DIN 2527, DN76/PN64(incl. spec. nut)
81 26-916Welding part, 3A/DN38, hygienic
81 26-917Welding part, 3A/DN76, hygienic
81 26-938Blind plug, 3A/DN38, hygienic
81 26-939Blind plug, 3A/DN76, hygienic
81 26-925Welding part, M44 x 1.25
81 69-G901Adaptor DIN 11851 for ø43 connection, DN40(incl. union)
81 69-G902Adaptor DIN 11851 for ø43 connection, DN50(incl. union)
81 69-G903Flange for ø43 connection mounting on 81 69-G911
81 69-G911Welding part for ø43 mm connection
81 26-920Reduction DS 228-1/ ISO 16288for 816x xxxx x1xxUnion G1/2 to nipple G1/2A
81 26-921Reduction DS 228-1/ ISO 16288for 816x xxxx x1xxUnion G1/2 to nipple G3/8A
81 26-922Reduction DS 228-1/ ISO 16288for 816x xxxx x1xxUnion G1/2 to nipple G1/4A
ø64
ø65
ø50.5
78
ø55
ø100
[mm]
32
32
ø50.5
78
ø65 ø84
15
4 holes ø11.5
Accessories for FlexBar HRT
81 26-923M4 damping screw for the reductions(81 26-920, 81 26-921, 81 26-922)
81 26-971O-Rings (5 pcs.), NBR, DN38, FDA approved
81 26-972O-Rings (5 pcs.), EPDM, DN38, FDA approved
81 26-973O-Rings (5 pcs.), Viton, DN38, FDA approved
81 26-976O-Rings (5 pcs.), NBR, DN76, FDA approved
81 26-977O-Rings (5 pcs.), EPDM, DN76, FDA approved
81 26-978O-Rings (5 pcs.), Viton, DN76, FDA approved
81 69-G981O-Rings (5 pcs.), NBR70, M44/ø43, FDA approved
81 69-G982O-Rings (5 pcs.), EPDM70, M44/ø43, FDA approved
81 69-G983O-Rings (5 pcs.), FPM70, M44/ø43, FDA approved
81 26-962Wall bracket for FlexBar HRT
80
64
97
81 26-926Teflon seal for M44 nipple, ø34.5 x ø40.5 x 0.8
82 23-903FlexProgrammer configuration set comprises:FlexProgrammer with 9 pole RS232C cable3.5" Program diskettesBattery plugCable with test plugs
81 26-950Factory assembly of accessories
81 26-960Calibration certificate
81 26-998Material certificate 3.1.b (EN 10204) - for wetted parts
[mm]
Accessories for FlexBar HRT
DescriptionCombiConnect is a series of hygienic, replaceableconnections in acid-proof stainless steel (W1.4404/AISI316L). The concept fits the G1/2A nipple versions ofFlexBar HRT pressure transmitter and the CombiTempPt100 sensor.The products comply with the strict demands from the foodindustry, represented by organisations such as 3A, FDAand EHEDG.It takes less than 2 minutes to mount the pressuretransmitter or Pt100 sensor on the CombiConnectconnection.CombiConnect is an entirely new concept offering highflexibility and a low stock. The connection system is theideal choice for customers measuring temperature andpressure in environments with several differentconnections.
Connection variantsDS 722: Dansk StandardDIN 11851: Deutsches Institut für
NormungSMS 1145: Sveriges Mekanförbunds
StandardcentralBS 4825 (RJT): British StandardISO 2853 (IDF) andISO 2852 (Clamp): International Standardisation
OrganisationVarivent and Tri-Clover®: Company Standards
DesignAcid-proof stainless steel, (W1.4404/AISI 316L).
Complies with the national standards DS 722, DIN 11851,
SMS 1145, BS 4825, ISO 2852 and ISO 2853.
Manufactured according to the relevant 3A Standards.
Complies with the demands in EN1672-2
Pressure range -1...25 bar
Vibrations Lloyds Register, test 2
Overpressure 400% of f.r., max. 600 bar(continuously)
Measures to be taken at hygienic mounting according to "European Hygienic Equipment Design Group"
1. Avoid blind pockets when connecting two pipe ends.
2. The gasket between nipple and union must be levelled with the surface.
3. The union nipple and the gasket must be centered in respect to each other.
4. Avoid blind pockets where media and cleaning materials can be accumulated.
O-rings0-ring Range Notes
Nitrile (NBR70) -30...100°C 1, 2
Etylene-propylene (EPDM70) -30...150°C 1
Fluorocarbon (FPM70) -20...200°C
Notes1 Complies with the demands from FDA
2 Change recommended after 50 CIP cleanings at 130°C
Disposal of product and packingAccording to national laws or by returning to Haenni.
CombiConnect - Technical Data
Hygienic Installations
CombiConnect Hygienic Replaceable Connections
8120 9xxx1234
01
12131415
202122232425
32333435
42434445
52535455
6B6C
7U
TypeComplete connection incl. O-ring, gasket and union ring 3Welding partUnion ring 3]GasketConnection
Varivent, Tuchenhagen GEA, DN40/DN50Connection
DS 722, DN40, UnionDS 722, DN40, NippleDS 722, DN50, UnionDS 722, DN50, NippleConnection
DIN 11851, DN25, UnionDIN 11851, DN25, NippleDIN 11851, DN40, UnionDIN 11851, DN40, NippleDIN 11851, DN50, UnionDIN 11851, DN50, NippleConnection
SMS 1145, DN38,UnionSMS 1145, DN38,NippleSMS 1145, DN51,UnionSMS 1145, DN51,NippleConnection
BS 4825, DN38, UnionBS 4825, DN38, NippleBS 4825, DN51, UnionBS 4825, DN51, NippleConnection
ISO 2853, DN38, UnionISO 2853, DN38, NippleISO 2853, DN51, UnionISO 2853, DN51, NippleConnection
ISO 2852, DN38, ClampISO 2852, DN51, ClampConnection
TriClover®, 3“, Clamp
CombiConnect
81 26-955Mounting tool for O-ringDIN 11851, DN25
81 26-956Mounting tool for O-ringDIN 11851, DN40/50BS 4825, DN38/51
81 26-957Mounting tool for O-ringISO 2853 and clamp, DN38/51SMS 1145, DN38/51
81 26-965O-ring for CombiConnect connections (5 pcs.)NBR, FDA approved
81 26-966O-ring for CombiConnect connections (5 pcs.)EPDM, FDA approved
81 26-967O-ring for CombiConnect connections (5 pcs.)FPM (Viton), FDA approved
3 Not valid for nipple and clamp connections
CombiConnect Accessories
CombiConnect - Ordering Details
DN40:ø54DN50:ø68
DN38:ø55DN51:ø65
DN38:ø54DN51:ø66.7
DN38:ø47DN51:ø60.5
DN40:ø58DN50:ø72
DN38:ø60DN51:ø70
DN38:ø58.2DN51:ø72.5
DN38:ø50.5DN51:ø64
DN25:ø44DN40:ø56
DN50:ø68.5
DN25:ø52DN40:ø65DN50:ø78
[mm]DN40/50:ø84
Clamp ISO 2852 DN38: ø50.5 Type no. 8120 916BClamp ISO 2852 DN51: ø64 Type no. 8120 916CTri-Clover® 3" ø90.9 Type no. 8120 917U
DS 722 8120 911x
DIN 11851 8120 912x
SMS 1145 8120 913x
BS 4825 (RJT) 8120 914x
ISO 2853 (IDF) 8120 915x
GEA Tuchenhagen Varivent 8120 9101
Clamp 8120 91xx
CombiConnect Connection Variants
CombiConnect connection
1 1) Mount the O-ring in CombiConnect.
2) The sensor tube must be screwed into the CombiConnect untilthere is a 2 to 5 mm gap between the O-ring and the bottom.
3) Press CombiConnect against the mounting tool to prevent theO-ring from sliding out. Tighten the sensor tube up at 20 Nm.
4) Tighten the safety-screw up at 2 Nm.
816x xx1x x1xx Mounting tool for CombiConnect FlexBar HRT withNipple G1/2A for CombiConnect CombiConnect
(+)
+ =
CombiConnect - Mounting Instructions
42 3
2...5 mm 2 Nm
20 Nm
50...100 N2 mm
H-3
40
0-3
-GB
/20
00
-07
-21
FlexBar HRT on the bracket for wall mounting
FlexBar HRT with M44 hygienic connectionmounted with welding part
FlexBar HRT with ø43 mm hygienic connection
Adaptor DIN 11851 for ø43 connection, DN40 (incl. union)
Adaptor DIN 11851 for ø43 connection, DN50 (incl. union)
Flange for ø43 connection mounting on a welding part
Welding part, ø65 mm for ø43 mm connection
FlexBar HRT with DN38 clamp separator
FlexBar HRT Accessories - Application Examples
Design and specifi cations subject to change without notice
Data Sheet 3501-1
Description
4...20 mA, 2-wire transmitter,HART® communication (Optional)
Stainless steel heavy duty housingwith LC-Display (Optional)
Confi gurable span, unit, damping and linearisation
Turn down 25:1
Accuracy better than 0.1%
Zero point adjustment
2-point calibration
Ranges 0...0.1 bar to -1(0)...70 bar
Gauge or absolute pressure
High overpressure safety limit
Demko EEx d [ia] IIC T4/T6, ATEX II 1G
Demko EEx ia IIC T4/T5, ATEX II 1G
Barbara Ex d [ia] IIC T4/T6
FlexBar 3501 is a loop powered, confi gurable pressure transmitter measuring absolute or gauge pressure.
The heavy duty housing in stainless steel, AISI 316, is specifi cally designed for applications in corrosive environments and medias.
FlexBar 3501 measures the pressure by means of a ceramic, capaci-tive sensor.
The measuring sensor and the electronics are in a separate chamber eliminating the risk of pressure and media in the terminal chamber.
FlexBar 3501 is confi gurable either with a handheld HART® com-municator or with the dedicated FlexProgrammer confi guring tool connected to a PC.
On-site adjustment of span and zero point can be made in hazardous zones with 4 push buttons on the transmitter.
The HART® communication features on-line process calibration/adjustment and transmitter confi guration.
FlexBar 3501 is used in chemical and petrochemical industries as well as in power plants and pulp and paper production.
If mounted with one of the hygienic connections, with fl ush mounted ceramic measuring cell, the FlexBar 3501 is the ideal pressure trans-mitter within harsh environmental measuring applications in the food-, beverage and pharmaceutical industry.
FlexBar 3501 Pressure Transmitter
Design and specifi cations subject to change without notice
Data Sheet 3501-1
InputMeasuring limits 0...0.1 bar to -1(0)...70 bar
Overpressure Specifi ed for each range See "Or de ring Details"
OutputNominal output 4...20 mA 1 2-wire, HART® communication
Linear output 3.5...21.5 mA
Output limits 3.5...23 mA 1
Characteristic Linear or customised with max. 30 points 1
Accuracy +/- 0.1%Including combined effects of linearity, hysteresis andrepeatability (max. turn down 1:5)
Hysteresis < 0.05%
Accuracy D/A converter < 0.05% of nominal output span
Isolation voltage > 500 Vac (From housing to 4...20 mA connection)
Resolution 14 bit
Load equation RL < (VCC-12)/23 [kOhm]
Display (optional)Type 4 digits, 7 segment LCD, and a DOT
matrix area 7 x 20 pixels
Display range -9999...+9999
Digit height 11.5 mm
Confi guring limitsURV limits 4...100% of full range 1
LRV limits 0...96% of full range 1
Adjustment limitsSpan -10...10% of read-out LSL < span < USL
Zero point -10...10% of full range
Auto zero -10...10% of full range Min. value > -1 bar rel. LSL < auto zero < USL
CommunicationFlexProgrammer PC-software (Windows) 2-way communication
HART® protocol HCF standard
Features 1 Read serial number Read/Change user ID Read/Change confi guration Read input signal value Read output signal value Input signal logging 2-point sensor trim Current output trim
Power supplyNominal 24 Vdc
Supply voltage 12...35 Vdc
Effects caused by changes in power supply:Zero point 0.005% per V (IEC 60770)
Measuring range 0.001% per V (IEC 60770)
Error handlingUp/Down scaling 1 23 mA/3.5 mA (NAMUR NE43)
Operational conditionsStorage temperature -40...85°C
Process temperature vs. type of O-ringO-ring, NBR -30...110°CO-ring, EPDM -40...120°CO-ring, VITON -20...125°C
Ambient temperature Without display -40...85°C With display -10...70°C
Relative humidity < 98%, cond. (IEC 68238)
Protection class IP 66 + IP 67
Vibrations Lloyds Reg. (IEC 60068-2-6) 5...25 Hz 4 mm ampl. 25...100 Hz 4g 100...150 Hz 2g 150...2000 Hz 1g
Shock test 100g for 10 msec.
Long term test IEC 60770
Operational condition effectsAmbient temperature infl uence, measured at -40...85°Cand p > 1.0 bar:
Zero point: < 0.1% per 10K
Span: < 0.1% per 10K
Transitional behaviourSwitch-on time < 2 sec.
Sample time < 0.25 sec.
Damping, t99 0...60 sec. (1 sec. steps) 1
Long-term drift Typ. 0.1% f.r. per year
EMC dataImmunity EN 50082-2, EN 61326
Emission EN 50081-1, EN 61326
NAMUR NE21
Approval (Demko) EEx d [ia] IIC T4/T6, ATEX II 1GApproval (Barbara) Ex d [ia] IIC T4/T6Temperature class T1...T4: -40 < Tamb < 85°C T1...T6: -40 < Tamb < 50°C
Max. supply voltage Umax= 30 Vdc
Zones Media: 0; Housing: 1
Approval (Demko) EEx ia IIC T4/T5, ATEX II 1GTemperature class T1...T4: -40 < Tamb < 85°C T1...T5: -40 < Tamb < 70°C
Barrier data U < 30 Vdc ; I < 0.1 A; P < 0.75 W
Zones Media: 0; Housing: 0
Internal inductivity 1.3 mH
Internal capacity 3 nF
Technical Data
Design and specifi cations subject to change without notice
Data Sheet 3501-1
Additional Description
Unless specifi ed FlexBar 3501 is supplied with a stan dard confi guration:Pressure at 4 mA: Lower range limit (LSL)Pressure at 20 mA: Upper range limit (USL)Damping: 0 sec.Device address: 0
FlexBar 3501 is available with 17 different integrated process connections and with seals according to the customers wishes. The housing is 270° rotatable in respect to the process connection.
The O-ring sealing between the process connection and the sensor is available in 3 types matching different medias. Accessories for FlexBar 3501 are usually supplied separately and must be assembled by the customer.
Having the HART® communication facilities the FlexBar 3501 can be operated as a conventional 4...20 mA device, or it can be connected to other HART® devices in a 2-wire HART® network, in one of three connection methods: Mixed-signal mode, Point-to-Point mode or Multi-drop mode. Please refer to HART® literature.
The integrated 4-digit LC-display is optional.
MaterialsHousing Stainless steel (AISI 316/W1.4401)
Surface Cast, passivated
Pressure sensor Ceramic capacitive sensor (Al2O3 - 96%)
Fill fl uid None in standard versions. In diaphragm seals according to customers specifi cations.
Wetted parts Acid-proof stainless steel (AISI 316L/W1.4404)
Electrical connectionCable entry Gland M20, Polyamid, IP 68 Gland M20, Brass, IP 66
Test conditionsConfi guration LRV = 0 bar ; URV = USL
Power supply 24 Vdc
Amb. temperature 20°C +/- 2°C
Amb. pressure 860...1060 hPa
Humidity 45...75% RH
Disposal of product and packingAccording to national laws or by returning to Bourdon-Haenni
Note1 Confi gurable
Technical Data
Terms Overview
Output (mA)
pressure (bar)LSL Full range USL
LRV limits
LRV Span URV Over pres su re limit
Auto Zero
Nom
inal
out
put
Line
ar o
utpu
t
Out
put l
imits
Dow
n sc
ale
limits
U
p sc
ale
limits Transfer curve.
Turn Down 1:5 (0...14 bar).
URV limits0% 96%
4% 100%
23.0
21.5
20.0
4.0
3.5
-1 0 7 14 70 105
Nominal curve for a -1...70 bar (rel) pres su re transmitter confi gured to a Turn Down 1:1
LSL Lower Sensor Limit
USL Upper Sensor Limit
LRV Lower Range Value
URV Upper Range Value
Design and specifi cations subject to change without notice
Data Sheet 3501-1
Confi guring
Pressure in
Span (+10%)
Zero (+10%)
Factory adjustment
Zero (-10%)
Span (-10%)
Pressure out
( I out and Display out )
FlexBar 3501 can be confi gured in three ways:
a) With the 4 push buttons.b) With a PC, the dedicated FlexProgrammer confi guring tool and the Flex-program software, version G1 or higher.c) With the HART® handheld confi gurator, model 275 (versions 3501 2xxx xxxx only).
The LRV-auto and URV-auto functions
are used to adjust the transmitter in e.g. tank level measurements:
a) Empty the tank to zero levelb) Set the LRV-auto function (output will be set to 4 mA)c) Fill the tank to the max. leveld) Set the URV-auto function (output will be set to 20 mA)
Confi guring with the push buttons
Action ResultPush button > 0.5 sec. and release Function/input valid
No action in 10 secs. Display process data No value stored
Push <M> Toggle functions
Push <E> (in Function) Accept function
Push <E> (in Input) Value stored Display process data
Push <U> Increase value
Push <D> Decrease value
Push and hold > 2 sec. Step with 0.01% of USLPush and hold > 7 sec. Step with 0.1% of USLPush and hold > 12 sec. Step with 1% of USLPush and hold > 17 sec. Step with 10% of USL
The functions of the push buttons
With display Symbol Without display SymbolMenu <Menu> Zero + <Z+>Up <Up> Zero - <Z->Down <Down> Span + <S+>Enter <Enter> Span - <S->
Functions for a transmitter with display:
ADJ Note CONF Note Zero 2 LRV Span 2 URVAuto zero 2 DampFactory LRV-auto 2 URV-auto 2
Functions for a transmitter without display:
Function <Z+> <Z-> <S+> <S-> NoteZero Up Down 2, 3Span Up Down 2, 3Auto zero Push Push 2, 4LRV-auto Push Push 2, 4URV-auto Push Push 2, 4
Notes
2 Apply reference pressure3 Measure loop current with ampere meter4 Push simultaneously
Confi guring with FlexProgrammer
Select engineering unit from: %, bar, mbar, PSI, mH2O, kPa, MPa, atm, inHG, mmHG.
Turn down 25:12-point sensor trim30-point linearisationLoggingOut-of-range valuesScaling of output currentTAG no. and notesInfo of cell type, materials, date, serial no.
Adjustment with the push buttons
Design and specifi cations subject to change without notice
Data Sheet 3501-1
[mm]
R 81
Front view (with display) Rear View Bottom View
NoteBehind the front cover are no parts requiring user intervention. Do not remove the front cover, when the transmitter is energised.Remove the rear cover to access the terminals for the 4...20 mA connection.
30
44
46.7132
153
503525
0
Ground connection
Dimensional Drawings
140
ISO2852 clamp, DN51 (front page photo) DS722, DN40 DIN11851, DN40fl ush mounted ceramic cell fl ush mounted ceramic cell fl ush mounted ceramic cell
Flanged seal, DIN2527 form B, (see table)fl ush mounted ceramic cell
Measure DN25 DN40 DN50 DN80
A 53.8 53.8 51.8 47.8
B 18 18 20 24
C ø115 ø150 ø160 ø200
D ø85 ø110 ø125 ø160
E ø14 ø18 ø18 ø18
Holes 4 4 4 8
3A/DN76 hygienic connection GEA Tuchenhagen, varivent DN40/50fl ush mounted ceramic cell fl ush mounted ceramic cell
ED
B
C
A
32 32
ø64ø54
32
ø56
31 20
32
12
ø84
ø68
ø91
ø72.3
Design and specifi cations subject to change without notice
Data Sheet 3501-1
Notes2 Not available with EEx d approvals
Type 5´ digit4...20 mA 4...20 mA with HART® communication Safety 6´ digit
Standard versionDemko EEx ia IIC T4/T5, ATEX II 1G Demko EEx d [ia] IIC T4/T6, ATEX II 1GBarbara Ex d [ia] IIC T4/T6 Cable connection 7´ digit
Female thread M20 - 2 pcs. Polyamid Gland M20, included Display 8´ digit
Without display Integrated, digital display O-ring 9´ digit
VitonEPDM (FDA approved)NBR
Process connection standard 10´ digitG1/2A gauge connection (DIN 16288) PN701/2“-14 NPT male nipple, ø3 mm hole PN70G1/2A male nipple, ø10 mm hole PN701/2“-14 NPT male nipple, ø10 mm hole PN70G1/2 female thread PN701/2“-14 NPT female thread PN701/2“-14 NPT male nipple, 1/4“-18 NPT, internal female thread 2 PN70DS722 rotating female nut, fl ush mount 2 DN40 PN16ISO2852 clamp, fl ush mount 2 DN51 PN403A hygienic connection, fl ush mount 2 DN76 PN40GEA Tuchenhagen Varivent, fl ush mount 2 DN40/50 PN40DIN11851 rotating female nut, fl ush mount 2 DN40 PN25Flanged seal, DIN2527 form B, fl ush mount 2 DN25 PN40Flanged seal, DIN2527 form B, fl ush mount 2 DN40 PN40Flanged seal, DIN2527 form B, fl ush mount 2 DN50 PN40Flanged seal, DIN2527 form B, fl ush mount 2 DN80 PN40G1/2A gauge connection (DIN 16288) for external or remote seal (reduced volume), PN70
Pressure type 11´ digitRelative pressure (bar) Absolute pressure (bar) Pressure range (over pressure limit) 12´ digit
-0.1...0.1 (-0.3...4) 0...0.1 (-0.3...6) -0.1...0.4 (-1...6) -0.4...1.0 (-1...10) 0...1 (-1...10)-1...4 (-1...25) 0...4 (-1...25) -1...10 (-1...40) 0...10 (-1...40) -1...20 (-1...40) 0...20 (-1...40) -1...40 (-1...60) 0...40 (-1...60)-1...70 (-1...105) 0...70 (-1...105)
Ordering Details - FlexBar 3501
3501 xxxx xxxx
1 2
1 2 4 5
1
1 2
1 2 3
1 2 3 4 5 6 8 A B C D E F G H J S
1 2
1 2 3 4 5 6 7 8 9
Design and specifi cations subject to change without notice
Data Sheet 3501-1
Resistance Power supply FlexBar 3501 > 250 Ohms (or master) pressure transmitter
NoteWhen the HART® communicator is used for confi guration of the FlexBar 3501, the total series resistance in the 4...20 mA loop must exceed 250 Ohms. The confi gurator must hold the device specifi c DDL to be able to address all available HART® features.
230 Vac
4...20 mA 24 Vdc
Master
12 mA (for 3 slaves) + HART® communication signals
4 mA 4 mA 4 mA
Device 1 Device 2 Device 3
NoteIn Multi-drop mode up to 15 slaves can be connected to a 2-wire cable. The transmitters are „parked“ at a fi xed output of 4 mA. Each device must have a unique device number different from 0. In case that one trans mit ter is given a device number of 0, the system will revert to Mixed-signal mode.
9000 0001 Bracket for mounting on wall or 2“ pipe9000 0002 Adaptor M20 to PG13.59000 0003 Adaptor M20 to NPT 1/2“-149000 0004 Gland, Ex d, M20 x 1.5, Brass, IP 669000 0005 Blind plug, Ex d, M20 x 1.5, Brass3501 9900 Confi guration according to customers specifi cations
Accessories
Confi guring Handheld HART® communicator, model 275
Non-Ex-Application Example, Point-to-point mode
Non-Ex-Application Example, Multi-drop mode
Design and specifi cations subject to change without notice
Data Sheet 3501-1
GB/
2002
-10-
01
This
dat
a sh
eet m
ay o
nly
be re
prod
uced
in fu
ll.FlexBar 3501 is approved by Demko for EEx d [ia] IIC T4/T6, ATEX II 1G according to the European standards EN 50014, EN 50018 and EN 50020 and by Barbara for Ex d [ia] IIC T4/T6.
Due to the heavy duty housing FlexBar 3501 is approved for EEx d and a barrier is not neccessary, provided that FlexBar 3501 is installed in accordance with prevailing guidelines for zone 0 or 1.The FlexBar 3501 can henceforth measure media classifi ed as zone 0 medias. However the housing must be installed in zone 1 or 2.
Hazardous area Safe area 230 Vac
4...20 mA 24 Vdc
FlexBar 3501 Power Supply (Ri > 250 Ohms for HART applications)
5 8
3 4
Zone 1
Zone 0
250 Ohm
FlexBar 3501 is approved by Demko for EEx ia IIC T4/T5, ATEX II 1G according to the European standards EN 50014 and EN 50020.
FlexBar 3501 must be installed in accordance with prevailing guidelines for zone 0 or 1, and a certifi ed, intrinsically safe zener barrier or isolation barrier with the maximum values Umax= 30 Vdc; Imax= 0.1 A ; Pmax= 0.75 W must be used.
Zone 0, 1 or 2 Safe area 230 Vac
4...20 mA 24 Vdc
FlexBar 3501 Power Supply (Ri > 250 Ohms for HART applications)
5 8
3 4
250 Ohm
Ex - Installation, Ex d
Ex - Installation, Ex ia
Design and specifi cations subject to change without notice
Data Sheet A131-9901-1
Description
The FlexProgrammer is the dedicated confi guring tool for all Bourdon-Haenni Flex-products (except FlexTop 2231 Profi bus PA transmitter).
The FlexProgrammer unit is easy to connect to a stan dard PC with the 9-pole RS232C connector.
Easy to install
Operated from a standard PC
Can confi gure all Flex-products
User-friendly software with help menus
FlexProgrammer
The software is available in 6 languages having help menus, which makes it self-explanatory and easy to operate.
The selected confi guration can be stored under a fi le name determined by the user. A print facility is available for hard copy records.
Design and specifi cations subject to change without notice
Data Sheet A131-9901-1
GB/
2002
-06-
01
This
dat
a sh
eet m
ay o
nly
be re
prod
uced
in fu
ll.
Technical Data
Supply voltageInternal DTR signal from PCOption External battery 9 V (PP3)Data input RS232C EMC data
Immunity EN 50082-1Emission EN 50081-1
82 23-903
9000 0007
The FlexProgrammer set comprises:FlexProgrammer with 1.5 m RS 232C cable with 9-pole plug3.5 inch diskettes with the Flex-program softwareBattery plugCable with test plugs
Adaptor for confi guring of FlexTop 2201, FlexTop Iso and FlexTop HRT
Environmental conditionsOperating temperature 0...50°CHumidity < 90% RH, non-condensingProtection class IP 42Disposal of product and packing
According to national laws or by returning to Bourdon-Haenni
HardwareThe FlexProgrammer can be connected to an IBM-compatible PC with the confi guration listed below: 386 processor 3.5" fl oppy drive 4 MB RAM Windows installed (3.11, 95, 98, NT, 2000, XP) A free serial RS 232C port (physical port) 2 MB free hard disk space
2 1
Note:Disconnect loop supply before connecting the FlexProgrammerto FlexTop 2201.
Flex
Prog
ram
mer
Com LPT
1 2
1 2
9 V
SoftwareThe Flex-program software must be installed on the hard disk by running the Setup.exe fi le.In the main menu the language and the COM-port can be selected. In the SETUP menu a choice between Celcius and Fahrenheit can be made.In the EDIT menu the relevant parameters for each Flex-product can be confi gured. At termination of the program the language and COM-port selections will be stored on the hard disk.
Power supplyIf the PC is unable to supply the FlexProgrammer from the serial port an external 9V (PP3) battery must be installed, using the battery plug supplied.The battery should be connected during confi guration only. Otherwise its lifetime will be reduced.
2 1
Installation
Example of application - Confi guring FlexTop 2201
Ordering Details - FlexProgrammer
D6.901 E / 1.01Design and specifications subject to change without notice
Special Designs for Piezoresistive Pressure Transmitters
Sp
ecia
l Des
igns
Ord
erE
DE
DE
DE
DE
DE
DE
DE
DE
DE
Dco
de
505
510
513
517
518
520
522
530
541
552
O-R
ing
sea
lN
itrile
2110
XX
XX
X
Sili
cone
2111
XX
XX
Vito
n21
12X
XX
X
EP
DM
2113
XX
XX
X
No
min
al P
osi
tio
nN
P 0
*02
17X
XX
XX
XX
NP
30*
0218
XX
XX
XX
X
NP
45*
0219
XX
XX
XX
X
NP
60*
0223
XX
XX
XX
X
NP
120
0220
XX
XX
XX
X
NP
135
0221
XX
XX
XX
X
NP
150
0224
XX
XX
XX
X
NP
180
0222
XX
XX
XX
X
9223
XX
XX
XX
X
Ele
ctri
cal c
onn
ecti
on
Cab
le w
ith in
sula
ting
pla
stic
tub
e
2130
XX
XX
XX
X
Cab
le w
ith in
sula
ting
pla
stic
tub
e an
d c
onne
ctor
Ben
dix
2130
/21
32X
XX
XX
XX
Hea
t re
sist
ing
cab
le –
55°C
... 1
55°C
2133
XX
XX
XX
X
Cab
le w
ith c
onne
ctor
Ben
dix
2132
XX
XX
XX
X
9001
XX
XX
XX
XX
X
Exe
cuti
on
Exe
cutio
n fo
r ox
ygen
0764
XX
XX
XX
XX
Free
of
silic
one
0794
XX
XX
X
Tran
smis
sio
n liq
uid
Sw
eet
alm
ond
oil
1311
XX
XX
XX
Ad
just
men
t te
mp
erat
ure
9007
XX
XX
XX
X
Ordering: A 4-digit ordering code is added to the order number for the pressure transmitter:e.g. ED 510/311.211/126/2130/9001/0035 (2130: cable compr. fitts, cable with ins. plastic, cable length 3,5 m)
Mat
eria
l(S
tand
ard
-Mat
eria
l is
NB
R,
for
ED
505
VIt
on)
*Cau
tion:
Rad
iate
d h
eat
can
rise
the
tem
per
atur
e of
the
tra
nsm
itter
cas
e ov
er
the
allo
wed
80°
C.
Sp
ecifi
cally
req
uest
nom
inal
pos
ition
Sp
ecia
lly r
eque
sted
cab
le le
ngth
(follo
win
g co
de:
cab
le le
ngth
in d
m)
Tem
per
atur
e of
ad
just
ing
med
ium
(follo
win
g co
de
corr
esp
ond
ing
to t
he t
emp
erat
ure
in °
C, e
.g. 9
007/
0120
)
ED
ED
ED
ED
NP
0
NP
30N
P 6
0N
P 4
5N
P 1
20N
P 1
35N
P 1
50
NP
120
Sta
ndar
d
S._39-40_Kat.Elekt.E 18.01.2001 15:46 Uhr Seite 39
D6.911.1 E / 1.01Design and specifications subject to change without notice
Accessories for Piezoresistive Pressure TransmittersPressure Transmitter ED 520 and ED 530Welding sleeve
Dimensions D a H Material Ordering no.
G 1⁄2 35 20 D 11737.0
Stainless steel 1.4435
G1 55 23 D 11737.2
Grooved nut according to IDF
Dimensions A E DN Material Ordering no.
48 42 1 D 11683.1
64 56 11⁄2’’ D 11683.2Stainless steel 1.4301
77 69 2’’ D 11683.3
91 83 21⁄2’’ D 11683.4
Front piece with thread
Dimensions D a b sw Material Ordering no.
G 1⁄2 9 23 27 D 11870.0
Stainless steel 1.4435
G1 15 27 41 D 11870.2
Adapter flange according to IDF PN 40
Dimensions D R H f d a t b l DN Material Ordering no.
G 1⁄2 16,45 20 33,8 25,6 29,2 2 5 6,5 1’’ D 11753.0002
47 38,6 42,7 2,5 6 8 11⁄2’’ D 11753.0104
Stainless steel 1.4435
G1 26,45 23 60,5 51,6 56,2 3 7 9,5 2’’ D 11753.0204
74 64,1 69,9 3,5 8 11 21⁄2’’ D 11753.0304
Pressure Transmitter ED 520Welding sleeve for connection without cone
Dimensions D a H Material Ordering no.
G 1⁄2 60 20.5 D 12403.0
Stainless steel 1.4435
G1 60 20.5 D 12403.1
Ø aD
H
S._41-44_Kat.Elekt.E 18.01.2001 15:47 Uhr Seite 41
D6.911.1 E / 1.01Design and specifications subject to change without notice
Accessories for Piezoresistive Pressure Transmitters
Pressure Transmitter ED 520 and ED 530Adapter flange according to DIN 11851 (milk fitting) PN 12
Dimensions Ordering example D 11752. 02 02
Dimension chart
D d6 d7 R H g t b lDN
G 1⁄2 36 30 16,45 20 8 2,5 5 6,5 20 02
50 41 26,45 23 10 2,5 6 8,5 32 04
56 48 26,45 23 10 3,5 7 9,5 40 05
68 61 26,45 23 11 3,5 8 8,5 50 06G1
86 79 26,45 23 12 4,5 10 7,5 65 07
100 93 26,45 23 12 4,5 10 7,5 80 08
121 114 26,45 23 15 – – – 100 09
Material stainless steel 1.4435 G 1⁄2 02
G1 04
Adapter flange according to DIN 2501 PN 40, with tongue and through holes
Dimensions Ordering example D 11755. 00 04
Dimension chart
D d1 d4 d5 k hDN
411 32 75 50 6 00
411 38 80 55 8 01
414 40 90 60 10 02
414 45 95 65 15 03
414 58 105 75 20 04G1
414 68 115 852
25 05
418 78 140 100 32 06
418 88 150 110 40 07
418 102 165 125 50 08
818 122 185 145 65 09
Material Stainless steel 1.4571 G1/2 04
Grooved union nut according to DIN 11851 (milk fitting) PN 12
Dimensions D E f DN Material Ordering no.
Rd 441⁄6’’ 48 20 20 N 2400.02
Rd 581⁄6’’ 62 21 32 N 2400.04
Rd 651⁄6’’ 70 21 40 N 2400.05
Rd 781⁄6’’ 84 22 50 Stainless steel 1.4301 N 2400.06
Rd 951⁄6’’ 102 25 65 N 2400.07
Rd 1101⁄6’’ 117 29 80 N 2400.08
Rd 1301⁄6’’ 138 31 100 N 2400.10
S._41-44_Kat.Elekt.E 18.01.2001 15:47 Uhr Seite 42
D6.911.2 E / 1.01Design and specifications subject to change without notice
Accessories for Piezoresistive Pressure Transmitters
Adapter flange
Dimensions D H R Material Ordering no.
Stainless steel 1.4435 D 11738.02
G 1⁄2 20 16,45
Hastelloy C D 11738.20
Stainless steel 1.4435 D 11738.22
G1 23 26,45
Hastelloy C D 11738.22
Pressure Transmitter ED 510Welding sleeve for ED 510/XXX.X4X
Dimensions D Material Ordering no.
G 1⁄2 Stainless steel D 12362.01.4435
Adapter for high temperature (cooling device)
Dimensions Tmed max. lT d Connection Material Ordering no.
D 11636.02
Connection dimension DRD
Box wrench
d
d
d
G1 ⁄2
’’G
1 ⁄2’’
G1 ⁄2
’’
G1 ⁄2
’’
G1 ⁄2
’’1 ⁄2 ’
’–14
-NP
T
lT
lT
lT
DIN 16288 DIN 3852
DIN 16288 DIN 16288
DIN 16288
300°C 123 40 G 1⁄2’’ D 12361.0
200°C 95 27 G 1⁄2’’ D 12361.1
150°C 68 27 G 1⁄2’’ D 12361.21
300°C 131 40 G 1⁄2’’ D 12361.2
200°C 103 27 G 1⁄2’’ D 12361.3
150°C 79 27 G 1⁄2’’ D 12361.22
300°C 125 40 1⁄2’’-14-NPT D 12361.6
200°C 97 27 1⁄2’’-14-NPT D 12361.7
150°C 70 27 1⁄2’’-14-NPT D 12361.23
Stainless steel1.4435
Stainless steel1.4435
Stainless steel1.4435
S._41-44_Kat.Elekt.E 18.01.2001 15:47 Uhr Seite 43
D6.911.2 E / 1.01Design and specifications subject to change without notice
Accessories for Piezoresistive Pressure Transmitters
Electrical accessoriesPressure transmitters with DIN-plug
Dimensions Designation Ordering code
Cable socket connector DIN 43 650 E 6844.0
Extension cable with socket connector1) E 6084.0xxx
Extension cable with socket and plug connectors1) E 6084.2xxx
Pressure transmitters with Binder-plug
Dimensions Designation Ordering code
Cable socket connector E 13265.0
Extension cable with socket and plug connectors1) E 6085.2xxx
Extension cable with socket connector1) E 6085.0xxx
Pressure transmitters with Bendix-plug
Dimensions Designation Ordering code
Cable socket connector E 6586.1
Extension cable with socket and plug connectors1) E 6738.3xxx
Extension cable with socket connector1) E 6737.0xxx
1) Specify cable length in order.
S._41-44_Kat.Elekt.E 18.01.2001 15:47 Uhr Seite 44
Design and specifications subject to change without notice
Data sheet A11.07
Measurement up to 1800 bar, absolute or gauge pressure
Thin film technology
Excellent long term stability
Zero adjustment as standard (±10% of range)
Welded construction – reinforced product
Modularity of electrical and hydraulic connections
Conforms to European EMC Directive, CE marked
Highly resistant to severe process conditions(≥ 10 7 pressure cycles)
Marine version (Bureau Veritas, DNV ...)
E510 with terminal strip outlet + screwed cap
Technical Data (20°C)
E510 Pressure transmitters
Measurement range Pressure (R or A): 0...60 bar to 0...1800 bar
Output signal E512: 0...10 Vdc. E513: 4...20 mA E514: 1...5 Vdc. E516: 0...20 mA
Supply voltage E512: 14...40 Vdc. E513 - E514: 11...40 Vdc.
E516: 8...40 Vdc. Option High voltage: up to 48 Vdc Low voltage: 8...32 Vdc (E513, E514)
Insulation > 100 MΩ at 100 Vdc. Option: 250 Vdc.
Maximum input current E512 - E514: 6 mA E516: < 25 mA
Load impedance (+M /-M) E512: ≥ 2,5 k Ω E514: ≥ 1 k Ω E513: RΩ ≤ (Ualim-11)/0.02 E513: RΩ ≤ (Ualim-8)/0.02 (low voltage option) E516: RΩ ≤ (Ualim-6)/0.02
CE -conformity Standards EN50082-1 and -2 (immunity) Standards EN50081-1 and -2 (emission) with
screened cable, screen connected at both ends Pressure standards 97/23/CE
Global error (linearity, hysteresis and repeatability) by reference to BFSL Typically: ±0.2% F.S. / Max.: ±0.3%F.S.
Long term stability zero : ≤ ± 0.2% F.S over 5 years sensibility : ≤ ± 0.1% over 5 years
Operating temperature Ambiant (Ta) Standard -25...+85°C Option Low T°: -40...+85°C. High T°: -25...+100°C Fluid -25...+100°C (Ta ≤ 50°C)
Storage temperature -40...+85°C
Compensated temperature range (zero and sensitivity) -10...+55°C. Option: -10...+70°C
Zero thermal drift ±0.025% F.S./°C max. Option: ±0,015% F.S./°C max.
Span thermal drift ±0.04%/°C / Option: ±0.01%/°C
Wetted parts 17-4 PH + 1.4404 (AISI 316 L) stainless steel
Standard connections Electrical: DIN 43650 connector Pressure: G1/2 Many options available
Protection rating (EN 60529) Standard: IP65 (DIN connector) Option: IP67 or IP68 (depending on connection)
Typical response time ≤ 3 ms
Vibration resistance (IEC 68-2-6) 1.5 mm (10 - 55 Hz), 20 g (55 Hz - 2 kHz)
Shock resistance (IEC 68-2-32) 25 falls from 1 m on concrete ground
Stainless steel transmitters intended for extremely diverse industrial applications: control of fluid flow, incorporation into equipment, continuous monitoring of fluid pressure, etc.
The sensing element of the E510 is based on thin film technology.
Design and specifications subject to change without notice
Data sheet A11.07
Design and specifications subject to change without notice
Data sheet A11.07www.bourdon-haenni.com
Page 3
Ø 35
Ø 27
104
75
10
Ø6 ... Ø8
Accès aux réglages
G1/2
20
S (option)
Z
3
2 1
27
Connections Connections
kg
0.350 0.350
Connections
E513
1 : +A2 : - A3 : : Ground
E512-E514-E516
1 : +M2 : - A / - M3 : +A : Ground
0.250
10
75
102
Ø 27
28
Ø4 ... Ø6
3
2 1
27
Ø 27
80
10
Ø6.5
27
Ø 27
95
80
10
Ø6.5
27
kgkg
kg
Dimensional Drawings - Mounting Details
Standard version. P ≥ 1 barDIN 43650 plug
E513
1 : +A2 : - A3 : : Ground
E512-E514-E516
1 : +M2 : - A / - M3 : +A : Ground
kg
Connections
Access to adjustments
Option 08DIN 43650C micro plug (8 mm)
Option 22Pig tail (length 1.5 m)
E513
+A : White- A : Blue : Ground
0.300
E512-E514-E516
+M : Yellow- A / - M : Blue+A : Red : Ground
Option 23Pig tail (length 1.5 m) + PG7 Cable gland
E513
+A : White- A : Blue : Ground
E512-E514-E516
+M : Yellow- A / - M : Blue+A : Red : Ground
Design and specifications subject to change without notice
Data sheet A11.07www.bourdon-haenni.com
Page 2 Design and specifications subject to change without notice
Data sheet A11.07
1 : Plug2 : Case3 : Seal4 : Connector5 : Nut6 : PG7 Cable gland (horizontal or vertical)
Connections
E512-E514-E516
+M : Yellow- A / - M : Blue+A : Red : Ground
E513
+A: White- A: Blue : Ground
E513
1 : +A2 : - A3 : : Ground
E512-E514-E516
1 : +M2 : - A / - M3 : +A : Ground
Connections
0.350 0.400
112
79,5
1011
1/2 NPT Ø6.5
27
27
Ø27
Ø6 ... Ø8
Ø 38
115
69
10
1
2
3
4
5
6
27
Optional accessory
Connections
E512-E514-E516
A : +AB : - A / - MC : +MD :E : GroundF :
E513
A : +AB : C : - AD :E : GroundF :
Connections
E512-E514-E516
1 : +A2 : +M3 : Ground4 : - A / - M
E513
1 : +A2 : 3 : Ground4 : - A
0.250 0.300 0.400
Cab
le le
ng
th
Connections
E513
+A : White- A : Blue : Ground
E512-E514-E516
+M : White- A / - M : Blue+A : Red : Ground
Ø 27
10
80
97
A
B
F E
D
C
27
9343
80
10
27
4
1 2
3
73
Ø 6.5
10
27
kg kg
kg kg kg
Dimensional Drawings - Mounting Details
Option 54Pig tail cable outlet with 1/2 NPT male (length 1.5 m)
Option 20Terminal strip outlet + screwed cap
Option 096 contacts HE302 plug
Option 24M12, 4 contacts plug
Option 27Submersible cable (IP68)
Design and specifications subject to change without notice
Data sheet A11.07
Pressure range 60 100 160 250 400 600 1000 1600 1800
Measurement range 66 110 176 275 440 660 1100 1760 1980
Max. over pressure 200 200 320 500 800 800 2000 2100 2100
Burst pressure 400 400 640 1000 1600 2500 2500 2500 2500
Model 1´...3´ digitStandard Output signal 4´ digit
0...10 Vdc4...20 mA1...5 Vdc0...20 mA
Hydraulic connection 5´...6´ digitG 1/4 (P ≤ 1000 bar)G 1/2 standard1/4 NPT (P ≤ 1000 bar)1/2 NPT (P ≤ 1000 bar)9/16"-18UNF-2B female
Pressure range 7´...9´ digitSee codes in tables Pressure type 10´ digit
AbsoluteGauge
E51x xx xxx x
E51 2 3 4 6
02 03 05 06 0T
xxx
A R
Measuring Ranges (bar)
Ordering Details - E510
B29B31B33B35B38B39B41B42B1F
code Range in bar
0 + 60 A R 0 + 100 A R 0 + 160 A R 0 + 250 A R 0 + 400 A R 0 + 600 A R 0 + 1000 A R 0 + 1600 A R 0 + 1800 A R
Options
Uncoded Options (have to be listed after the code)DegreasedLightning protectionMarine versionSupply voltage (high/low)(1)
Ambient temperature (high/low)(1)
Compensated temperature range (- 10...+70°C)Zero thermal drift: ±0.015% of range/°C max.Span adjustment ±10% of rangeSpan adjustment ±50% of range (except for 1600 and 1800 bar ranges) Calibration of sensor with certificate: Q1060Thread lockingOther hydraulic connectionsAdditional length of cableStainless steel surface mounting brackets Other units: kPa (code D), MPa (code E), kg/cm² (code F), psi (code H), mbar (code N)
Coded OptionsOther electrical connections: 08.DIN 43650C micro plug (IP65 (2)) 22.Pig tail (1.5 m) (IP65) 23.Pig tail (1.5 m) + PG7 cable gland (IP65, IP67 (3)) 54.Pig tail cable outlet with 1/2 NPT male (1.5 m) (IP65) 20.Terminal strip outlet + screwed cap (IP65, IP67) 09.6 contacts HE302 plug (IP65) 24.M12, 4 contacts plug (IP65) 27.Submersible cable (IP68 version (4))
(1) see specifications for details / (2) IP65 : water spray / (3) IP67 : temporary immersion /(4) IP68 : prolonged immersion
UK/
10-2
002
Thi
s da
ta s
heet
may
onl
y be
repr
oduc
ed in
full.
Design and specifications subject to change without notice
Data sheet A11.03
Measurement of vacuum, absolute or gauge pressure
TRANSBAR® ceramic technology
Zero adjustment as standard (±10% of range)
Welded construction – reinforced product
Modularity of electrical and hydraulic connections
Conforms to European EMC Directive, CE marked
Highly resistant to severe process conditions (≥ 107 pressure cycles)
Marine version (Bureau Veritas ...)
All stainless steel transmitter
Stainless steel transmitters intended for extremely diverse industrial applications: control of fluid flow, incorporation into equipment, continuous monitoring of fluid pressure, etc.
Based on TRANSBAR® ceramic technology, these transmitters are compatible with the majority of process fluids.
Technical data (20°C)
E910 with IP68 option
E910 Pressure Transmitter
Measurement range From 0...25 mbar to 0...600 bar Compound, gauge or absolute pressure
Output signal E912: 0...10 Vdc. E913: 4...20 mA (except -1...0 bar where -1 = 20 mA, 0 = 4 mA)
E914: 1...5 Vdc. E916: 0...20 mA
Supply voltage E912: 14...40 Vdc E913-E914: 11...40 Vdc E916: 8...40 Vdc Option High voltage up to 48 Vdc Low voltage: 8...32 Vdc (E913, E914)
Insulation > 100 MΩ at 250 Vdc. Option: 500 Vdc.
Maximum input current E912-E914: 6 mA E916: < 25 mA
Load impedance (+M / –M) E912: ≥ 2.5 k Ω E913: RΩ ≤ (Usupply-11)/0.02 E913: RΩ ≤ (Usupply-8)/0.02 (low voltage option) E916: RΩ ≤ (Usupply-6)/0.02
CE Conformity Directive 89/336 CE (EN50082-1 and -2, EN50081-1 and -2) with screened cable, screen connected at both ends
Directive 97/23/CE : 3.3 for P < 200 bar and cat 1 for P ≥ 200 bar.
Global error (linearity, hysteresis and repeatability) by reference to BFSL Typically: ±0.2% of F.S. / Max.: ±0.3% of F.S. For P ≤ 60 mbar and P= 600 bar: Typically: ±0.6% of F.S. / Max.: ±1% of F.S.
Operating temperature Ambient (Ta) -25...+85°C Option Low T°: -40...+85°C. High T°: -25...+100°C Fluid -25...+100°C (Ta ≤ 50°C)
Storage temperature -40...+85°C
Compensated temperature range (zero and sensitivity) -10...+55°C. Option: -10...+70°C
Zero thermal drift ±0.025% F.S./°C max. (except P ≤ 1 bar: ±0.06% F.S./°C) Option: ±0.015% F.S./°C max. (except P ≤ 1 bar: ±0.025% F.S./°C)
Span thermal drift Typically: ±0.01%/°C / Max.: ±0.015%/°C
Wetted parts Ceramic + stainless steel 1.4404 (316L) + NBR seal (standard) for ranges > 250 mbar and Viton® for ranges ≤ 250 mbar
Standard connections Electrical: DIN 43650 connector Pressure: G1/2 Many options available
Protection rating (EN 60529) Standard: IP65 (DIN connector) Option: IP67 or IP68 (depending on connection)
Typical response time ≤ 3 ms
Vibration resistance (IEC 68-2-6) 1.5 mm (10-55 Hz), 20 g (55 Hz to 2 kHz)
Shock resistance (IEC 68-2-32) 25 falls from 1 m on concrete ground
Design and specifications subject to change without notice
Data sheet A11.03
Design and specifications subject to change without notice
Data sheet A11.03www.bourdon-haenni.com
Page 3
G1/2
20
Ø 41,111
7
98Ø 49, P < 250 mbar
27
Ø 27
Standard version. P ≥ 1 barDIN 43650 plug
Ø 35
Ø 27
96
67
10
Ø6 ... Ø8
G1/2
20
S
Z
3
2 1
27
Standard version for P < 1 barDIN 43650 plug
Version also used for -1...0 bar and 0...1 bar ranges with ±50% span adjustment option.
E913
1 : +A2 : - A3 : : Ground
E912E914E916
1 : +M2 : - A / - M3 : +A : Ground
Connections
0.4000.300
Option : Stainless steel surface mounting brackets
Access to adjustments
41.5
BOURDON HAENNI
kg kg
[xx] : dimensions and weight for "P < 1 bar" versions.
Ø 27
87 [
108]
72 [
93]
10
Ø6,5
27
Option 23Pig tail (length 1.5 m) + PG7 Cable gland
Option 22Pig tail (length 1.5 m)
Connections
0.350 [0.450] 0.350 [0.450]
E913
+A : White- A : Blue : Ground
E912-E914-E916
+M : Yellow- A / - M : Blue+A : Red : Ground
Option 08DIN 43650C micro plug (8 mm)
10
67 [
98]94
[11
5]
Ø 27
28
Ø4 ... Ø6
3
2 1
27
Connections
E913
1 : +A2 : - A3 : : Ground
E912-E914-E916
1 : +M2 : - A / - M3 : +A : Ground
0.250 [0.350]
Ø 27
72 [
93]
10
Ø6,5
27
Connections
E913
+A : White- A : Blue : Ground
E912-E914-E916
+M : Yellow- A / - M : Blue+A : Red : Ground
kg kg kg
Dimensional Drawings (mm) - Mounting Details
Design and specifications subject to change without notice
Data sheet A11.03www.bourdon-haenni.com
Page 2 Design and specifications subject to change without notice
Data sheet A11.03
Ø6 ... Ø8
Ø 38
107
[128
]
61 [
82]
10
1
2
3
4
5
6
27
Connections
E912-E914-E916
+M : Yellow- A / - M : Blue+A : Red : Ground
E913
+A: White- A: Blue : Ground
104
[125
]
71,5
[92
,5]
1011
1/2 NPT Ø6,5
27
27
Ø27
E913
1 : +A2 : - A3 : : Ground
E912-E914-E916
1 : +M2 : - A / - M3 : +A : Ground
Connections
0.350 [0.450] 0.400 [0.500]
Ø 27
10
72 [
93]
89 [
110]
A
B
F E
D
C
27
85 [
106]
43
72 [
93]
10
27
4
1 2
3
Connections
E912-E914-E916
A : +AB : - A / - MC : +MD :E : GroundF :
E913
A : +AB : C : - AD :E : GroundF :
Connections
E912-E914-E916
1 : +A2 : +M3 : Ground4 : - A / - M
E913
1 : +A2 : 3 : Ground4 : - A
0.250 [0.350] 0.300 [0.400] 0.400 [0.500]
Connections
E913
+A : White- A : Blue : Ground
E912-E914-E916
+M : White- A / - M : Blue+A : Red : Ground
1065
[86
]
Ø 6,5
27
kg kg
kg kg kg
Dimensional Drawings (mm) - Mounting Details[xx] : dimensions and weight for "P < 1 bar" versions.
Option 20terminal strip outlet + screwed cap
Option 54Pig tail cable outlet with 1/2 NPT male (length 1.5 m)
1 : Plug2 : Case3 : Seal4 : Connector5 : Nut6 : PG7 Cable gland (horizontal or vertical)
Optional accessory
Option 096 contacts HE302 plug
Option 24M12, 4 contacts plug
Option 27Submersible cable (length 1.5 m)
Cab
le le
ngth
Design and specifications subject to change without notice
Data sheet A11.03
Options
Uncoded Options (have to be listed after the code)DegreasedLightning protectionMarine versionSupply voltage (high/low)(1)
Ambient temperature (high/low)(1)
Compensated temperature range (- 10...+70°C)Zero thermal drift: ±0.015% of range/°C max.Span adjustment ±10% of rangeSpan adjustment ±50% of range (except for ranges ≤ 0...+0.25 bar and 0...+600 bar) Calibration of sensor with certificate: Q1060Thread lockingOther hydraulic connectionsAdditional length of cableStainless steel surface mounting brackets Other units: kPa (code D), MPa (code E), kg/cm² (code F), psi (code H), mbar (code N)Atmospheric pressure measurement (Range: 800...1200 mbar absolute)
Coded Options
Other electrical connections: 08.DIN 43650C micro plug (IP65 (2)) 22.Pig tail (1.5 m) (IP65) 23.Pig tail (1.5 m) + PG7 cable gland (IP65, IP67 (3)) 54.Pig tail cable outlet with 1/2 NPT male (1.5 m) (IP65) 20.Terminal strip outlet + screwed cap (IP65, IP67) 09.6 contacts HE302 plug (IP65) 24.M12, 4 contacts plug (IP65) 27.Submersible cable (IP68 version (4))
Model 1´...3´ digitStandard Output signal 4´ digit
0...10 Vdc4...20 mA1...5 Vdc0...20 mA
Hydraulic connection 5´...6´ digitG 1/4G 1/2 standard1/4 NPT1/2 NPT Sensor seal 7´ digit
NBR (Nitril) standardCR (Neoprene) (P ≥ 250 mbar)EPDM (P ≥ 250 mbar)Kalrez® (P ≥ 1 bar)FKM (Viton®) Pressure range 8´...10´ digit
See codes in tables Pressure type 11´ digit
AbsoluteGauge
Kalrez® and Viton® are registered trademarks of DuPont Dow Elastomers
Measuring Ranges
Ordering Details - E910
(1) see specifications for details / (2) IP65 : water spray / (3) IP67 : temporary immersion /(4) IP68 : prolonged immersion
E91x xx x xxx x
E91 2 3 4 6
02 03 05 06
3 4 5 7 9
xxx
A R
Pressure in mbar Pressure in bar
compound pressure — — — — — — — — -1+0 -1+0.6 -1+1.5 -1+3 -1+5 -1+9 -1+15 -1+24 -1+39 — — — — — —
pressure 25 40 60 100 160 250 400 600 1 1.6 2,5 4 6 10 16 25 40 60 100 160 250 400 600
Measurement range 27.5 44 66 110 175 275 440 660 1.1 1.75 2.75 4.4 6.6 11 17.6 27.5 44 66 110 176 275 440 660
Max. over pressure 110 110 275 500 500 1000 1000 1000 3 3 4 8 12 20 32 50 80 120 200 320 500 600 800
Burst pressure 200 200 500 1000 1000 2000 2000 2000 6 6 7 12 18 30 48 75 120 180 300 480 600 800 1000
Range in mbar 0 + 25 – R 0 + 40 – R 0 + 60 – R 0 + 100 – R 0 + 160 – R 0 + 250 A R 0 + 400 A R 0 + 600 A R
code Range in bar. Vacuum pressure
-1 + 0 – R -1 + 0.6 – R -1 + 1.5 – R -1 + 3 – R -1 + 5 – R -1 + 9 – R -1 + 15 – R -1 + 24 – R -1 + 39 – R 0 + 1 A R 0 + 1.6 A R 0 + 2.5 A R 0 + 4 A R 0 + 6 A R 0 + 10 A R 0 + 16 A R 0 + 25 A R 0 + 40 A R 0 + 60 A R 0 + 100 A R 0 + 160 A R 0 + 250 A R 0 + 400 A R 0 + 600 A R
code
B59B72B74B76B77B79B81B82B1LB15B16B18B19B20B22B24B26B27B29B31B33B35B38B39
UK/
09-2
002
Thi
s da
ta s
heet
may
onl
y be
repr
oduc
ed in
full.
N05N06N07N08N09N10N11N12
Design and specifications subject to change without notice
Data sheet A11.04
Pressure and vacuum measurements, absolute or gauge
Ceramic, TRANSBAR® sensing element
Zero adjustment (±10% of range)
Welded construction – reinforced product
Modularity of electrical and hydraulic connections
Stainless steel flush diaphragm
Conforms to European EMC Directive, CE marked
Highly resistant to severe process conditions
Intrinsically safe versions (Y920): LCIE 99-E6074Xcertificat ; EEX ia IIC T6 or T5 approval
Marine version (Bureau Veritas, DNV ...)
Measurement range 0...1.6 bar to 0...600 bar compound pressure, gauge or absolute pressure. (according to the pressure connection)Output signal E922-Y922: 0 ...10 Vdc / E924-Y924: 1...5 Vdc E923-Y923: 4-20 mA / E926-Y926: 0...20 mA
Supply voltage E922: 14...40 Vdc Y922: 14...28 Vdc E923-E924: 11...40 Vdc Y923-Y924: 11...28 Vdc E926: 8...40 Vdc Y926: 8...28 Vdc Option High voltage: up to 48 Vdc Low voltage: 8...32 Vdc (E923, E924)
For intrinsically safe versions Y920, power supply electrical parameters device must be: Usupply ≤ 28 Vdc ; I ≤ 120 mA ; P ≤ 0.8 W
Insulation > 100 MΩ at 250 Vdc. Option: 500 Vdc
Maximum input current E922-Y922 / E924-Y924: 6 mA E926-Y926: < 25 mA
Load inpedance (+ M /-M) E922-Y922: ≥ 2,5 kΩ E924 -Y924: ≥ 1 kΩ E923: RΩ ≤ (Usupply-11)/0.02 E923: RΩ ≤ (Usupply-8)/0.02 (low voltage option)
E926: RΩ ≤ (Usupply-6)/0.02
CE -conformity Standards EN50082-1 and -2 (immunity) Standards EN50081-1 and -2 (emission) with screened cable, screen connected at both ends Pressure standards 97/23/CE
Global error (linearity, hysteresis and repeatability) by reference to BFSL Typically: ± 0.2% of F.S. / Max.: ± 0.3% of F.S. For P= 600 bar : Typically: ± 0.6% of F.S. / Max.: ± 1% of F.S.
Storage temperature - 40...+ 85°C (standard version)
Compensated temperature range (zero and sensitivity) - 10...+ 55°C. Option: -10...+ 70°C
Operating temperature
Ambiant (Ta) Standard E920 -15...+85°C Option Low T°: -40...+ 85°C / High T°: -25...+100°C Standard Y920 -25...+40°C (T6 approval) -25...+70°C (T5 approval) Fluid -25...+100°C (Ta ≤ 50°C) Option High T°-25...+150°C (Ta ≤ 50°C)
Zero thermal drift ±0.025% F.S./°C max. Option: ±0.015 % F.S./°C max
Span thermal drift typically: ±0.01%/°C-max: ±0.015%/°C
Wetted parts St. steel flush diaphragm 1.4404 (316 L) + 1 or 2 NBR o'rings
Connection Electrical: DIN 43650 connector (standard) Pressure: G1/2 (flufh diaphragm), 1 or 2 o'rings Filling oil: LRS 1, -15...+150°C (standard) LRS 5, -40...+150°C LRS 7, -20...+80°C (paint application) Many options available
Protection rating IP65 (DIN connector)(EN 60529) Option: IP67 or IP68 (depending on connection)
Typical response time ≤ 3 ms
Vibration resistance 1,5 mm (10-55 Hz), 20 g (55 Hz-2 kHz)(EN 60068-2-6)
Shock resistance 25 falls from 1 m on concrete ground(EN 60028-2-32)
Weight From 0.300 to 0.900 kg. Depending on versions.
E920 Pressure transmitter with flush diaphragm
Specifications (20°C)
An all stainless steel construction with flush diaphragm connection makes these transmitters ideally suited for measurements on viscous and heavy fluids suchs as paint, pulp and paper, and most uses in the refrigeration field.Hydraulic connections: G 1/2, G 3/4, G 1, 1/2 NPT.
Design and specifications subject to change without notice
Data sheet A11.04
Design and specifications subject to change without notice
Data sheet A11.04www.bourdon-haenni.com
Page 3
D
Ø6 ... Ø8
Ø27
Ø30
S (option)
Z
Ø27
Ø27
Ø30
3030
20.5
20.5
Ø18 Ø18
Ø18.2
10.5
min
i
15
3232
20.5
20.5
Ø23.8 Ø23.8
Ø24
10.5
min
i
15
4141
20.5
20.5
Ø30 Ø30
Ø30.1
10.5
min
i
15
27
15 m
ini
2020
a=99
a=13
6
a a a
a
a
a
a
Ø6 ... Ø8 Ø6 ... Ø8
a a
28
a=74
Ø35
Option 54Pig tail cable outlet
with 1/2 NPT male (1.5 m)Option 08
DIN 43650C micro plugDIN 43650 connector
(standard)
Code: DG DL DK DM DF DN E5
G1/2, 1 o'ring G1/2, 2 o'rings G3/4, 1 o'ring G3/4, 2 o'ring G1, 1 o'ring G1, 2 o'ring 1/2 NPT
o'ring Ø22x2o'ring Ø27x1.5
Access to adjustments
Type B:G1/2, P > 100 barG3/4, P ≥ 2.5 bar G1, P ≥ 1.6 bar1/2 NPT, P ≥ 4 bar
Type A:G1/2 (standard), 4 ≤ P ≤ 100 bar
+A +M -A -A / -M +A Ground
White +A Blue -A -A / -M Red +A Yellow +M Ground
o'ring Ø22x2
o'ring Ø15x1.5
o'ring Ø27x1.5
o'ring Ø21x1.5
Configuration and dimensions (mm) of the transmitterElectrical connections
Transmitter body
Hydraulic connections
Option 23Pig tail + PG7 cable gland
(1.5 m)
Option 22pig tail(1.5 m)
Design and specifications subject to change without notice
Data sheet A11.04www.bourdon-haenni.com
Page 2 Design and specifications subject to change without notice
Data sheet A11.04
D
Ø6 ... Ø8
Ø27
Ø30
S (option)
Z
Ø27
Ø27
Ø30
3030
20.5
20.5
Ø18 Ø18
Ø18.2
10.5
min
i
15
3232
20.5
20.5
Ø23.8 Ø23.8
Ø24
10.5
min
i
15
4141
20.5
20.5
Ø30 Ø30
Ø30.1
10.5
min
i
15
27
15 m
ini
2020
a=99
a=13
6
a a a
a
a
a
a
Ø6 ... Ø8 Ø6 ... Ø8
a a
28
a=74
Ø35
Option 096 contacts HE302 plug
Option 24M12 4 contacts plug
Option 27Submersible cable (IP68)
Option
Code: DG DL DK DM DF DN E5
G1/2, 1 o'ring G1/2, 2 o'rings G3/4, 1 o'ring G3/4, 2 o'ring G1, 1 o'ring G1, 2 o'ring 1/2 NPT
Body transmitter dimension according tothe electrical connection (a in mm)
(1) no access to adjustments
o'ring Ø35x1.5
Type C:high temperatureoptionT° ≤ 150°C
+A +M -A -A / -M +A Ground
White +A +M Blue -A -A / -M Red +A Ground
+A +A +M Ground -A -A / -M
+A +A -A / -M -A +M Ground
o'ring Ø35x1.5
o'ring Ø27x1.5
Option 20Terminal strip outlet +
screwed cap
a (mm) Type A Type B Type C DIN 43650 connector 74 99 136 Micro DIN 43650C connector 74 99 136 Pig tail 78.5 103.5 140.5 Pig tail + PG7 cable gland 78.5 103.5 140.5 Pig tail calble outlet with 1/2 NPT 78 103 140 Terminal strip outlet + screwed cap 113 138 175 6 contacts HE302 plug 83.5 108.5 145.5 M12, 4 contacts plug 77 102 139 Submersible cable, IP68(1) 81.5 106.5 143.5
Configuration and dimensions (mm) of the transmitter
Design and specifications subject to change without notice
Data sheet A11.04
Options
Measuring Ranges
Ordering - E920
Model 1´...3´ digitStandard Intrinsically safe Output signal 4´ digit
0...10 Vdc4...20 mA1...5 Vdc0...20 mA
Hydraulic connection 5´...6´ digitG1/2 flush diaphragm 1 o'ring (standard)G1/2 flush diaphragm 2 o'rings (standard)G3/4 flush diaphragm 1 o'ringG3/4 flush diaphragm 2 o'ringsG1 flush diaphragm 1 o'ring G1 flush diaphragm 2 o'rings1/2 NPT flush diaphragm (without o'ring) Sensor seal 7´ digit
NBR (Nitril) standardCR (Neoprene)EPDM(3)
FKM (Viton®) Pressure range 8´...10´ digit
See codes in tables Pressure type 11´ digit
AbsoluteGauge
Viton® is registered trademarks of DuPont Dow Elastomers(3) for low temperature applications (-40°C)
x92x xx x xxx x
E92Y92 2 3 4 6
DG DL DK DM DF DN E5
3 4 5 9
xxx
A R
UK/
2002
-09
Thi
s da
ta s
heet
may
onl
y be
repr
oduc
ed in
full
Uncoded Options (have to be listed after the code)
DegreasedLightning protectionMarine versionSupply voltage (high/low)(1)
Ambient temperature (high/low)(1)
Compensated temperature range (- 10...+70°C)Zero thermal drift: ±0.015% of range/°C max.Span adjustment ±10% of rangeSpan adjustment ±50% of range (except for 0 +1.6 and 0 + 600 bar) Calibration of sensor with certificate: Q1060Other hydraulic connectionsAdditional length of cableFilling oil: LRS5, LRS7Stainless steel surface mounting brackets Other units: kPa (code D), MPa (code E), kg/cm² (code F), psi (code H), mbar (code N)
Pressurerange
compound -1+0.6(1) -1+1.5(2) -1+3 -1+5 -1+9 -1+15 -1+24 -1+39 — — — — — —
pressure 1.6(1) 2.5(2) 4 6 10 16 25 40 60 100 160 250 400 600
Measurement range 1.75 2.75 4.4 6.6 11 17.6 27.5 44 66 110 176 275 440 660
Max. over pressure 3 4 8 12 20 32 50 80 120 200 320 500 600 800
Burst pressure 6 7 12 18 30 48 75 120 180 300 480 600 800 1000(1) G 1 connection only(2) G 3/4 and G 1 connections only
code Range in barVacuum pressure, Pressure
-1 + 0.6(1) – R -1 + 1.5(2) – R -1 + 3 – R -1 + 5 – R -1 + 9 – R -1 + 15 – R -1 + 24 – R -1 + 39 – R 0 + 1.6(1) A R 0 + 2.5(2) A R 0 + 4 A R 0 + 6 A R 0 + 10 A R 0 + 16 A R 0 + 25 A R 0 + 40 A R 0 + 60 A R 0 + 100 A R 0 + 160 A R 0 + 250 A R 0 + 400 A R 0 + 600 A R
(1) G 1 connection only(2) G3/4 and G 1 connections only
Coded OptionsOther electrical connections: 08. DIN 43650C micro plug (IP65 (2)) 22. Pig tail (1.5 m) (IP65) 23. Pig tail (1.5 m) + PG7 cable gland (IP65, IP67 (3)) 54. Pig tail cable outlet with 1/2 NPT male (1.5 m) (IP65) 20. Terminal strip outlet + screwed cap (IP65, IP67) 09. 6 contacts HE302 plug (IP65) 24. M12, 4 contacts plug (IP65) 27. Submersible cable (IP68 version (4))
(1) see specifications for details / (2) IP65: water spray / (3) IP67: temporary immersion / (4) IP68: prolonged immersion
B72B74B76B77B79B81B82B1LB16B18B19B20B22B24B26B27B29B31B33B35B38B39
Design and specifications subject to change without notice
Data sheet A11.05
Stainless steel 1.4404 (316L) flush diaphragmMeasurement of vacuum, absolute or gauge pressureTRANSBAR® ceramic technologyZero adjustment as standard (±10% of range)Welded construction – reinforced productVarious types of pressure ports : CLAMP, SMS, DIN , or homogeneizer (0...60 bar to 0...400 bar)Modularity of electrical and hydraulic connectionsConforms to European EMC Directive, CE marked Highly resistant to severe process conditionsIntrinsically safe versions (Y930) : LCIE 99-E6074X certificat ; EEX ia IIC T6 or T5 approval approval (option)
Measurement range 0...0.25 bar to 0...40 bar Compound, gauge or absolute pressure 0...60 bar to 0...400 bar homogeneization version
Output signal E932 - Y932 : 0...10 Vdc / E934 - Y934 : 1...5 Vdc E933 - Y933 : 4...20 mA / E936 - Y936 : 0...20 mA
Supply voltage E932 : 14...40 Vdc Y932 : 14...28 Vdc E933 - E934 : 11...40 Vdc Y933 - Y934 : 11...28 Vdc E936 : 8...40 Vdc Y936 : 8...28 Vdc Option High voltage : up to 48 Vdc Low voltage : 8...32 Vdc (E933, E934)
For intrinsically safe versions Y930, power supply electrical parameters device must be : Ualim ≤ 28 Vdc ; I ≤ 120 mA ; P ≤ 0.8 W
Insulation > 100 MΩ at 250 Vdc. Option 500 Vdc
Maximum input current E932 - Y932 / E934 - Y934 : 6 mA E936 - Y936 : < 25 mA
Load impedance (+ M / - M) E932 - Y932 : ≥ 2.5 kΩ E934 -Y934 : ≥ 1 kΩ E933: RΩ ≤ (Usupply-11)/0.02 E933: RΩ ≤ (Usupply-8)/0.02 (low voltage option) E936: RΩ ≤ (Usupply-6)/0.02
CE -conformity Standards EN50082-1 and -2 (immunity) Standards EN50081-1 et -2 (emission) with sreened cable, screen connected ar both ends Pressure standards 97/23/CE
Protection rating IP65 (DIN connector)(EN 60529) Option : IP67 or IP68 (depending on connection)
Global error (linearity, hysteresis and repeatability) by reference to BFSL Typ.: ±0.2% F.S. / Max.: ±0.3% F.S.
Compensated temperature range (zero and sensitivity) - 10...+55°C. Option : - 10...+70°C
Operating temperature
Ambient (Ta) Standard E930 - 15...+85°C High T° option - 15...+100°C Standard Y930 - 15...+40°C (T6 approval) - 15...+70°C (T5 approval) Fluid - 15...+100°C (Ta ≤ 50°C) High T° option - 15...+150°C (Ta ≤ 50°C) Sterilizing 140°C max for 30 minutes Storage - 40...+85°C
Zero thermal drift ±0.025% FS/°C max. Option : ±0.015 % FS/°C max ±0.04% FS/°C max. for P < 1 bar
Span thermal drift Typ. : ±0.01%/°C - Max : ±0.015%/°C
Wetted parts Stainless steel 1.4404 (316L) flush diaphragm
Connections Electrical : DIN 43650 connector (standard) Pressure : Clamp, DIN, SMS, welded conical threaded nipple. Filling oil (FDA approved) : LRS1, -15...+150°C (standard) Many options available
Typical response time ≤ 3 ms
Vibration resistance 1.5 mm (10 - 55 Hz), 20 g (55 Hz - 2 kHz)(EN 60068-2-6)
Shock resistance 25 falls from 1 m on concrete ground(EN 60028-2-32)
Weight From 0.300 to 1.5 kg depending on versions
E930 Transmitter for sanitary use
Technical Data (20°C)
The hygiene flush diaphragm transmitters of the E930/Y930 series are ideally suited to fulfill the pressure measurement requirements of the food, dairy and pharmaceutical industries among others.The cleanliness requirements of the food processing industry have dictated the "hygienic" design of these transmitters. They can also withstand without damage the various cleaning phases specific to these industries : sterilizing cycles, autoclaving and steam flushing.
Design and specifications subject to change without notice
Data sheet A11.05
Design and specifications subject to change without notice
Data sheet A11.05www.bourdon-haenni.com
Page 3
Type B :high temperatureoptionT° ≤ 150°CAccess to adjustments
Type A :G1/2 standardP ≥ 1 bar
Type C :P < 1 bar
Option 08DIN 43650C micro plug
DIN 43650 connector(standard)
CLAMP ISO 2852 DIN 11851FF DIN 11851FL SMS 1145FF SMS 1145FL DR0 DR2 DR8 Homogeneizer 622 Homogeneizer 623 2.5 ≤ P ≤ 40 bar 0.6 ≤ P ≤ 40 bar 7 ≤ P ≤ 400 bar 60 ≤ P ≤ 600 bar 60 ≤ P ≤ 600 bar
Configuration and dimensions (mm) of the transmitter
Electrical connections
Transmitter body
Hydraulic connections
E/Y933 E/Y932/4/6 E/Y933 E/Y932/4/6 E/Y933 E/Y932/4/6
E/Y933 E/Y932/4/6
E/Y933 E/Y932/4/6E/Y933 E/Y932/4/6
Ø6 ... Ø8 Ø6 ... Ø8
D
Ø6 ... Ø8
Ø27
S (option)
Z
Ø27
a=10
5
a a
a a a
a
a
a
a
28
a=68
Ø35
Ø41,1
Ø41,1
a=94
a=12
2
41
30
Bar
2.5 ≤ P < 40 Bar
Bar Bar
Bar
39
47
53 53 53
3030
21
34
52 52
18 18
43.9 G1/2G11/4
G150
1
2
3
1
2
4
1
2
1
2
4
1
2
5 5
1
2
1
2
3
4
5
0.4 ≤ P < 40
0.25 ≤ P < 40
0.6 ≤ P ≤ 40
0.4 ≤ P ≤ 40
0.25 ≤ P ≤ 40
0.6 ≤ P ≤ 40
0.4 ≤ P ≤ 40
0.25 ≤ P ≤ 40
0.4 ≤ P ≤ 40
0.25 ≤ P ≤ 40 0.4 ≤ P ≤ 40
0.25 ≤ P ≤ 40
+A +M -A -A / -M +A
Ground
White +A Blue -A -A / -M Red +A Yellow +M Ground
Connection accessories
Option 54Pig tail cable outlet
with 1/2 NPT male (1.5 m)
Option 23Pig tail +
PG7 cable gland (1.5 m)
Option 22pig tail(1.5 m)
Design and specifications subject to change without notice
Data sheet A11.05www.bourdon-haenni.com
Page 2 Design and specifications subject to change without notice
Data sheet A11.05
Especially dedicated to food, chemistry,
pharmaceutical industries
Option
+A +M -A -A/-M +A Masse
Blanc +A +M Bleu -A -A / -M Rouge +A Tresse
+A +A +M Masse -A -A / -M
+A +A -A/-M -A +M
Masse
Option 20Terminal strip outlet +
screwed cap
Option 096 contacts HE302 plug
Option 24M12 4 contacts plug
Option 27Submersible cable (IP68)
Type D :P < 1 barHigh temperatureoptionT° ≤ 150°C
Seal (EPDM)
Endpiece
Collar
Nut Welded nipple
Connection accessories are uncoded options (have to be listed after the code number)
CLAMP ISO 2852 DIN 11851FF DIN 11851FL SMS 1145FF SMS 1145FL DR0 DR2 DR8 Homogeneizer 622 Homogeneizer 623 2.5 ≤ P ≤ 40 bar 0.6 ≤ P ≤ 40 bar 7 ≤ P ≤ 400 bar 60 ≤ P ≤ 600 bar 60 ≤ P ≤ 600 bar
Configuration and dimensions (mm) of the transmitter
(1) no access to adjustments
Body transmitter dimension according to the electrical connection (a in mm)
a (mm) Type A Type B Type C Type D DIN 43650 connector 68 105 94 122 Micro DIN 43650C connector 68 105 94 122 Pig tail 72.5 109.5 98.5 126.5 Pig tail + PG7 cable gland 72.5 109.5 98.5 126.5 Pig tail cable outlet with 1/2 NPT 72 109 98 126 Terminal strip outlet + screwed cap 107 144 133 161 6 contacts HE302 plug 77.5 114.5 103.5 131.5 M12, 4 contacts plug 71 108 97 125 Submersible cable, IP68(1) 75.5 112.5 101.5 129.5
E/Y933 E/Y932/4/6 E/Y933 E/Y932/4/6 E/Y933 E/Y932/4/6
E/Y933 E/Y932/4/6
E/Y933 E/Y932/4/6E/Y933 E/Y932/4/6
Ø6 ... Ø8 Ø6 ... Ø8
D
Ø6 ... Ø8
Ø27
S (option)
Z
Ø27
a=10
5
a a
a a a
a
a
a
a
28
a=68
Ø35
Ø41,1
Ø41,1
a=94
a=12
2
41
30
Bar
2.5 ≤ P < 40 Bar
Bar Bar
Bar
39
47
53 53 53
3030
21
34
52 52
18 18
43.9 G1/2G11/4
G150
1
2
3
1
2
4
1
2
1
2
4
1
2
5 5
1
2
1
2
3
4
5
0.4 ≤ P < 40
0.25 ≤ P < 40
0.6 ≤ P ≤ 40
0.4 ≤ P ≤ 40
0.25 ≤ P ≤ 40
0.6 ≤ P ≤ 40
0.4 ≤ P ≤ 40
0.25 ≤ P ≤ 40
0.4 ≤ P ≤ 40
0.25 ≤ P ≤ 40 0.4 ≤ P ≤ 40
0.25 ≤ P ≤ 40
Design and specifications subject to change without notice
Data sheet A11.05
Options
Measuring Ranges (bar)
Ordering Details - E930
Model 1´...3´ digitStandard Intrinsically safe Output signal 4´ digit
0...10 Vdc4...20 mA1...5 Vdc0...20 mA
Hydraulic connection 5´...7´ digitCLAMP ISO DN 25CLAMP ISO DN 38CLAMP ISO DN 51SMS FF DN 38SMS FF DN 51 SMS FL DN 38 + nutSMS FL DN 51 + nut DIN FF DN 32DIN FF DN 40DIN FF DN 50DIN FL DN 32 + nutDIN FL DN 40 + nutDIN FL DN 50 + écrouDR0 (G1 with conical threading)DR2 + nutDR8 (G1/2 with conical threading)Homogeneization version with nutHomogeneization version with flange Pressure range 8´...10´ digit
See codes in tables Pressure type 11´ digit
AbsoluteGauge
x93x xx x xxx x
E93Y93 2 3 4 6
125 138 151 238 251 338 351 432 440 450 532 540 550 DR0 DR2 DR8 622 623
xxx
A R
Uncoded Options (have to be listed after the code) Coded Options
Pressurerange
compound — — — -1+0 -1+0.6 -1+1.5 -1+3 -1+5 -1+9 -1+15 -1+24 -1+39 — — — — — —
pressure 0.25 0.4 0.6 1 1.6 2.5 4 6 10 16 25 40 60 100 160 250 400 600
Measurement range 0.275 0.44 0.66 1.1 1.75 2.75 4.4 6.6 11 17.6 27.5 44 66 110 176 275 440 660
Max. over pressure 1 1 1 3 3 4 8 12 20 32 50 80 120 200 320 500 600 800
Burst pressure 2 2 2 6 6 7 12 18 30 48 75 120 180 300 480 600 800 1000
Lightning protectionSupply voltage (high/low)(1)
Ambient temperature (high/low)(1)
Compensated temperature range (- 10...+70°C)Zero thermal drift: ±0.015% of range/°C max.Span adjustment ±10% of rangeSpan adjustment ±50% of range (except for P ≤ 1 bar) Calibration of sensor with certificate: Q1060Stainless steel surface mounting bracketsOther hydraulic connections (Micro-CLAMP DN 17.2, ...)Additional length of cableOther units: kPa (code D), MPa (code E), kg/cm² (code F), psi (code H), mbar (code N)
approval
Other electrical connections: 08. DIN 43650C micro plug (IP65 (2)) 22. Pig tail (1.5 m) (IP65) 23. Pig tail (1.5 m) + PG7 cable gland (IP65, IP67 (3)) 54. Pig tail cable outlet with 1/2 NPT male (1.5 m) (IP65) 20. Terminal strip outlet + screwed cap (IP65, IP67) 09. 6 contacts HE302 plug (IP65) 24. M12, 4 contacts plug (IP65) 27. Submersible cable (IP68 version (4))
(1) see specifications for details / (2) IP65: water spray / (3) IP67: temporary immersion / (4) IP68: prolonged immersion
Code Range in bar.Vacuum pressure. Pressure
B59 -1 + 0 B72 -1 + 0.6 B74 -1 + 1.5 B76 -1 + 3 B77 -1 + 5 B79 -1 + 9 B81 -1 + 15 B82 -1 + 24 B1L -1 + 39 B10 0 + 0.25 B11 0 + 0.4 B12 0 + 0.6 B15 0 + 1 B16 0 + 1.6 B18 0 + 2.5 B19 0 + 4 B20 0 + 6 B22 0 + 10 B24 0 + 16 B26 0 + 25 B27 0 + 40
B29 0 + 60 B31 0 + 100 B33 0 + 160 B35 0 + 250 B38 0 + 400 B39 0 + 600
See in the central pages the pressure compatibilities charts according to the hydraulic connection
UK/
2002
-09
Thi
s da
ta s
heet
may
onl
y be
repr
oduc
ed in
full
Design and specifications subject to change without notice
Data sheet A11.06
TRANSBAR® technologyExcellent long term stabilityWelded construction - reinforced productConforms to European EMC Directive, CE markedProduct identification laser etched on caseIntrinsically safe versions (Y940) : LCIE 99-E6074X certificate ; EEX ia IIC T6 or T5 approvalMarine version (Bureau Veritas, DNV ...)
Protective capLightning protectionMarine versionSupply voltage (high/low)(1)
Compensated temperature range (from -10...+70°C)Zero thermal drift : ±0.015 % of range/°C max.Cell o'ring : Viton®
Additional length or other material of cable Other ranges and unitsCleat with built-in anchor (100 daN)
Viton® is registered trademark of DuPont Dow Elastomers(1) see specifications for details
Measurement range Gauge pressure : 0...2.5 to 0...160mH2O
Output signal E942 - Y942 : 0...10 Vdc / E944 - Y944 : 1...5 Vdc E943 - Y943 : 4...20 mA / E946 - Y946 : 0...20 mA
Supply voltage E942 : 14...40 Vdc Y942 : 14...28 Vdc E943 - E944 : 11...40 Vdc Y943 - Y944 : 11...28 Vdc E946 : 8...40 Vdc Y946 : 8...28 Vdc Option High voltage: up to 48 Vdc Low voltage: 8...32 Vdc (E943, E944)
For intrinsically safe version Y940, power supply must be : Usupply ≤ 28 Vdc ; I ≤ 120 mA ; P ≤ 0.8 W
Insulation > 100 MΩ at 250 Vdc. Option: 500 Vdc
Maximum input current E942 - Y942 / E944 - Y944 : 6 mA E946 - Y946 : < 25 mA
Load impedance (+ M / - M) E942 - Y942 : ≥ 2.5 kΩ E944 -Y944 : ≥ 1 kΩ E943: RΩ ≤ (Usupply-11)/0.02 E943: RΩ ≤ (Usupply-8)/0.02 (low voltage option) E946: RΩ ≤ (Usupply-6)/0.02
CE -conformity Standards EN50082-1 and -2 (immunity) Standards EN50081-1 and -2 (emissions : a factor of 100 below the permitted maximum) with screened cable, screen connected at both ends Pressure standards 97/23/CE
Global error (linearity, hysteresis and repeatability) by reference to BFSL Typ.: ±0.2% F.S. / Max.: ±0.3% F.S.
Operating temperature Standard E940 - 25...+85°C Standard Y940 - 25...+40°C (T6 approval) - 25...+70°C (T5 approval)
Storage temperature - 40...+85°C
Compensated temperature range (zero and sensitivity) - 10...+55°C. Option : - 10...+70°C
Zero thermal drift ±0.025% FS/°C max (except P 10 mH2O: ±0.06% FS/°C) Option ±0.015 % FS/°C max (except P ≤ 10 mH2O: ±0.025% FS/°C)
Span thermal drift Typically ±0.01%/°C - Max : ±0.015%/°C
Wetted parts Ceramic + stainless steel 1.4404 (316 L) + NBR seal (standard) + cable (polyurethane) Option seal viton® and insuladed cable in ETFE
Standard connections Electrical vented watertight cable Hydraulic G 1/2 for Ø41 (P < 10 mH2O) G 1/4 for Ø23 (P ≥ 10 mH2O) Option protective cap
Protection rating IP68 (Depth = 160 m)(EN 60529)
Vibration resistance 1.5 mm (10 - 55 Hz), 20 g (55 Hz - 2 kHz)(EN 60068-2-6)
Shock resistance 25 falls from 1 m on concrete ground (EN 60028-2-32)
E940 Submersible level transmitter
Technical Data (20°C)
Uncoded Options (have to be listed after the code)
E940, low pressure version (P<10 mH2O)
protection cap (option)The submersible level transmitters E940/Y940 are engineered for a wide variety of industrial and municipal liquid level measurement applications requiring watertight protection.
Design and specifications subject to change without notice
Data sheet A11.06
Ø 27
106
G1/2
Ø 41,1
10G1/4
7610
Ø 23
P 10 mH2O P < 10 mH2OCâble Ø 6.5Lo
ngue
ur d
u câ
ble
kg
0.500
kg
0.180
A
Ø B
A B
P ≥ 10 mH2O 25 22 P < 10 mH2O 25 26,7
Dimensions (mm)
Measuring Ranges (mH2O)
Ordering Details - E940
Model 1´...3´ digitStandard Intrinsically safe Output signal 4´ digit
0...10 Vdc4...20 mA1...5 Vdc0...20 mA
Cable length 5´...7´ digit
Measurement unit 8´ digit
mH2Obarkg/cm2
Pressure range 9´...10´ digit
See codes in tables
x94x xx x xxx
E94Y94 2 3 4 6
J B F
xx
Pressure 0 + 2.5 0 + 4 0 + 6 0 + 10 0 + 16 0 + 25 0 + 40 0 + 60 0 + 100 0 + 160 Max. over pressure 10 10 10 30 30 40 80 120 200 320 Burst pressure 20 20 20 60 60 70 120 180 300 480
Pressure ranges mH2O bar, kg/cm2 Code
10 0 + 2.5 0 + 0.25 11 0 + 4 0 + 0.4 12 0 + 6 0 + 0.6 15 0 + 10 0 + 1 16 0 + 16 0 + 1.6 18 0 + 25 0 + 2.5 19 0 + 40 0 + 4 20 0 + 60 0 + 6 22 0 + 100 0 + 10 24 0 + 160 0 + 16
Length 2 m 3 m 4 m 5 m 6 m 10m 15m 16m 20m 25m 40m 60m 100m 160m others
code 002 003 004 005 006 010 015 016 020 025 040 060 100 160 xxx
Electrical connections
White Blue Screen Red Yellow
4-20 mA + supply - supply ground — —
1-5 V / 0-10 V / 0-20 mA — - supply/- meas. ground + supply + meas.
Protective cap (optional)
Cleat (optional)
Breaking load : 100 daN
UK/
2002
-10
Thi
s da
ta s
heet
may
onl
y be
repr
oduc
ed in
full
Specifications (20°C)
With built-in chemical seal top housing, these pressure transmitters (stainless steel body and chemical seal) available in two sizes (equivalent to D100 and D200) provide pressure measurement from 0 + 0.6 bar R/A to 0 + 160 bar R/A and from -1 + 0 bar R to -1 + 39 bar R. The built-in housing also gives the standard model the same measuring specifications as the E910. The welded diaphragm, made of stainless steel 1.4404 (AISI 316 L) on standard model, can be produced in hastalloy, tantalum, PTFE coating, etc. to make it compatible with most industrial fluids.The transmitters are delivered with a coupling and bolts for mounting on a variety of mechanical fixtures. They can also be delivered fitted on process mechanical mounts derived from the D101/D201/D411/D420/D611/D621 range (bottom housings, clamps) to form assemblies ready to mount on the process.
• Built-in industrial chemical seal derived from the D100/D200 family
• Very many mechanical interfacing possibilities• Full pressure range achieved with only one chemical seal
size• Various materials possible for the wetted parts• Intrinsically safe version (Y970), electrical parameters (see
Y910)
• Conforms to European EMC Directive, CE marked
11/0
2 -
N°
A11
.08
UK
Pressure transmitters
Standard E970Intrinsically safe Y970
Measurement range: 0 ... 1 to 0 ... 160 bar
D100E, D101E, D111E -1 ... 1.5 to -1 ... 39 bar
0 ... 0.6 to 0 ... 40 bar D200E, D201E, D211E -1 ... 1.5 to -1 ... 39 bar
0 ... 1 to 0 ... 160 bar D411E, D421E -1 ... 3 to -1 ... 24 bar
0 ... 1 to 0 ... 160 bar D611E, D621E -1 ... 0 to -1 ... 24 bar
Output signal: E972 - Y972 : 0 - 10 Vdc E973 - Y973 : 4 - 20 mA (except - 1 + 0 bar where - 1 = 20 mA, 0 = 4 mA) E974 - Y974 : 1 - 5 Vdc E976 - Y976 : 0 - 20 mA
Supply voltage: E972 : 14 to 40 Vdc Y972 : 14 to 28 Vdc E973 - E974 : 11 to 40 Vdc Y973 - Y974 : 11 to 28 Vdc E976 : 8 to 40 Vdc Y976 : 8 to 28 Vdc Option: high voltage: up to 48 Vdc low voltage: 8 - 32 Vdc (E973, E974) For Y970 intrinsically safe versions, the electrical parameters of the associated equipment are: Ualim ≤ 28 Vdc ; I ≤ 120 mA ; P ≤ 0.8 W (see Y910)
Insulation: >100 MΩ at 250 Vdc. Option: 500 Vdc
Maximum input current: E972 - Y972 / E974 - Y974 : 6 mA E976 - Y976 : < 25 mA
Load impedance (+M /–M): E972 - Y972 : ≥ 2.5 k Ω E974 -Y974 : ≥ 1 k Ω E973: RΩ ≤ (Usupply-11)/0.02 E973: RΩ ≤ (Usupply-8)/0.02 (low voltage option) E976: RΩ ≤ (Usupply-6)/0.02
Electromagnetic compatibility: • Standards EN50082-1 and -2 (immunity) • Standards EN50081-1 and -2 (emission) with shielded cable, shield connected at both ends.
Global error (linearity, hysteresis and repeatability) by reference to BFSL: Typically: ±0.2% of F.S. /
Max.: ±0.3% of F.S.
Operating temperature: • Ambiente (Ta): Standard E970: - 25 to + 85°C Option E970 : Low T °: - 40 to + 85°C / High T °: - 25°C to 100°C Standard Y970: - 25 to + 40°C for T6 approval - 25 to + 70°C for T5 approval • Fluid: Version E970: -25 to + 100°C standard (other on request) Version Y970: according to T6 or T5
Storage temperature: - 40°C to + 85°C
Compensated temperature range (zero and sensitivity): Standard: - 10 to + 55°C. Option: - 10 to + 70°C
Zero thermal drift: ±0,025% EM/°C Max.(except P ≤ 1 bar: ±0.06% F.S./°C) Span thermal drift: Typically: ±0.01%/°C - Max.: ±0.015%/°C
Wetted parts: Flush diaphragm stainless steel 1.4404 (316L) (standard)
Standard electrical and hydraulic connections: See following pages Transmitting fluid: LRS1 : -15 … 150°C (standard)
Protection rating (EN 60529): Standard: IP65 (DIN connector) Option: IP67 or IP68 (depending on connection)
Typical response time: ≤ 3 ms
Vibration resistance (EN 60068-2-6): 1.5 mm (10 - 55 Hz), 20 g (55 Hz - 2 kHz)
Shock resistance (EN 60028-2-32): 25 falls from 1 m on concrete ground.
Modifications reserved.
Dimensions (mm), connections
Ø6 ... Ø8 Ø6 ... Ø8
D
Ø6 ... Ø8
a a a a a
a
a
a
a
28
Ø 41.1
a=98
Ø 27Ø 27
a=68
S
Z
D100E, D200E D101E, D201E D111E, D211E D411E, D421E D611E, D621E
Electrical connections
Transmitter body
Hydraulic connections
DIN 43650 connector (standard)
+A +M -A -A / -M +A Ground
White +A Blue -A -A / -M Red +A Yellow +M Braid
Access for adjustment
Type A:
standardP ≥ 1 bar
Option 08DIN 43650C micro plug
(8 mm)
Option 54Pig tail (1.5 m) with 1/2 NPT
Option 23Pig tail (length 1.5 m)
+ PG7 cable gland
Option 22Crimped pig tail (length 1.5 m)
Option 20Terminal strip outlet + screwed cap
Ø6 ... Ø8 Ø6 ... Ø8
D
Ø6 ... Ø8
a a a a a
a
a
a
a
28
Ø 41.1
a=98
Ø 27Ø 27
a=68
S
Z
D100E, D200E D101E, D201E D111E, D211E D411E, D421E D611E, D621E
+A +M -A -A/-M +A Ground
White +A +M Blue -A -A / -M Red +A Braid
+A +A +M Ground -A -A / -M
+A +A -A/-M -A +M Ground
Type B:
P < 1 barBody transmitter dimension according to the electrical
connection (a in mm)
Dimension a (mm) Type A Type B
DIN 43650 connector 68 98 Micro DIN 43650C connector 68 98 Pig tail 72.5 102.5 Pig tail + PG7 cable gland 72.5 102.5 Pig tail cable outlet with 1/2 NPT 72 102 Terminal strip outlet + screwed cap 107 137 6 contacts HE302 plug 77.5 107.5 M12, 4 contacts plug 71 101 Submersible cable, IP68(1) 75.5 105.5
(1) no access to adjustments
Option 20Terminal strip outlet + screwed cap
Option 096 contacts HE302 plug
Option 27Submersible cable (IP68)
Option 24M12 4 contacts plug base
Measuring ranges
Ordering details
Mod
ifica
tion
s re
serv
ed.
Options
9 7 *TRANSMITTER Model: Standard E Intrinsically safe Y Type: 97 Output signal: 0-10 Vdc 2 4-20 mA 3 1-5 Vdc 4 0-20 mA 6
CHEMICAL SEAL Type: D100E D100E D101E D101E D111E D111E D200E D200E D201E D201E D211E D211E D411E D411E D421E D421E D611E D611E D621E D621E Top housing material: Stainless steel 1.4404 (316L) (standard): SS Others: UR - NI - HB - HC - TA - MO Diaphragm material: Stainless steel 1.4404 (316L) (standard): SS Others: Uranus B6 (UR) - Nickel (NI) - Hastelloy B (HB) - Hastelloy C276 (HC) - Tantalum (TA) - Monel 400 (MO) Transmitting fluid: LRS1 (-15 ... 150°C) (standard): 1 LRS2 (-60 ... 150°C): 2 - LRS3 (-30 ... 30°C): 3 - LRS4 (-15 ... 150°C, oxygen): 4 Bottom housing material (D101E, D111E, D201E, D211E only): Stainless steel 1.4404 (316L) (standard): SS Others: UR - NI - HB - HC - TA - MO Bottom housing connection (D101E, D111E, D201E, D211E only): Male thread: G 1/2 (M001) - 1/2 NPT (M003) - G 3/8 (M004) - G 1/4 (M007) - other threads (M000) Female thread: G 1/2 (F001) - 1/2 NPT (F012) - other threads (F000)
Pressure in bar
Compound pressure — -1+0 -1+0.6 -1+1.5 -1+3 -1+5 -1+9 -1+15 -1+24 -1+39 — — —
Pressure 0.6 1 1.6 2.5 4 6 10 16 25 40 60 100 160
Measurement range 0.7 1.1 1.75 2.75 4.4 6.6 11 17.6 27.5 44 66 110 176
Maximum overpressure 1 3 3 4 8 12 20 32 50 80 120 200 320
Burst pressure 2 6 6 7 12 18 30 48 75 120 180 300 480
Uncoded options have to be listed after the code*
Chemical seal definition
Uncoded Options (have to be listed after the code)DegreasedLightning protectionMarine versionSupply voltage (high/low)(1)
Ambient temperature (high/low)(1)
Compensated temperature range (- 10...+70°C)Span adjustment ±10% of rangeSpan adjustment ±50% of range Calibration of sensor with certificate: Q1060Other electrical connectionsAdditional length of cableOther units: kPa (code D), MPa (code E), kg/cm² (code F), psi (code H), mbar (code N)
Coded Options
Other electrical connections: 08.DIN 43650C micro plug (IP65 (2)) 22.Pig tail (1.5 m) (IP65) 23.Pig tail (1.5 m) + PG7 cable gland (IP65, IP67 (3)) 54.Pig tail cable outlet with 1/2 NPT male (1.5 m) (IP65) 20.Terminal strip outlet + screwed cap (IP65, IP67) 09.6 contacts HE302 plug (IP65) 24.M12, 4 contacts plug (IP65) 27.Submersible cable (IP68 version (4))
(1) see specifications for details / (2) IP65 : water spray / (3) IP67 : temporary immersion /(4) IP68 : prolonged immersion
Design and specifications subject to change without noticeData sheet A11.09
Compound and gauge pressure measurement
All stainless steel pressure gauge
Ceramic sensor, TRANSBAR® technology
Zero and span adjustments as standard (±10% of range)
Voltage surge and reverse polarity protection
Intrinsically safe version (Y8900)EEx ia IIc T6 (or T5) approval
Conforms to European EMC directive, CE marked
Technical Data (20°C)
E8900 Pressure gauge with transmitter
Measurement range Compound pressure: -1...0 to -1...24 bar Gauge pressure: 0...1 to 0...400 bar
Output signal E89X2-Y89X2: 0...10 Vdc. E89X3-Y89X3: 4...20 mA (except -1...0 bar or -1 = 20 mA, 0 = 4 mA)
E89X4-Y89X4: 1...5 Vdc. E89X6-Y89X6: 0...20 mA
Supply voltage E89X2: 14...40 Vdc. Y89X2: 14...28 Vdc E89X3-E89X4: 11...40 Vdc.
Y89X3-Y89X4: 11...28 Vdc E89X6: 8...40 Vdc. Y89X6: 8...28 Vdc Option High voltage : up to 48 Vdc Low voltage: 8...32 Vdc (E89X3, E89X4) For intrinsically safe versions Y8900, power supply
electrical parameters device must be : Usupply ≤ 28 Vdc ; I ≤ 120 mA ; P ≤ 0.8 W
Insulation > 100 MΩ at 250 Vdc. Option: 500 Vdc.
Maximum input current E89X2-Y89X2 / E89X4-Y89X4: 6 mA E89X6-Y89X6: < 25 mA
Load impedance (+M / –M) E89X2-Y89X2: ≥ 2.5 k Ω E89X4-Y89X4: ≥ 1 k Ω E89X3: RΩ ≤ (Usupply-11)/0.02 E89X3: RΩ ≤ (Usupply-8)/0.02 (low voltage option ) E89X6: RΩ ≤ (Usupply-6)/0.02
CE -conformity Standards EN50082-1 and -2 (immunity) Standards EN50081-1 et -2 (emission: a factor of
100 below the permitted maximum) with sreened cable, screen connected ar both ends
Pressure standards 97/23/CE
Pressure gauge accuracy Ø 63 mm (E8930) : ±1.6 % of full scale(EN 837-1) Ø 100, 150 and 160 mm (E8950, E8970, E8980) :
±1% of full scale
Global error (linearity, hysteresis and repeatability) by reference to BFSL Typically: ±0.2% of F.S. / Max.: ±0,3%F.S.
Operating temperature Ambient (Ta) Standard E910 -25...+85°C Option E910 Low T°: -40...+85°C. High T°: -25...+100°C Standard Y910 -25...+40°C (T6 approval) -25...+70°C (T5 approval) Fluid -25...+100°C (Ta ≤ 50°C)
Storage temperature -40...+85°C
Compensated temperature range (zero and sensitivity) -10...+55°C. Option: -10...+70°C
Thermal drift (transmitter)
Zero ±0.025% FS/°C max. Option: ±0.015% FS/°C Sensibility ±0.015% FS/°C max.
Case Stainless steel 1.4301 (304)
Wetted parts Ceramic + stainless steel 1.4404 (316 L) + NBR seal
Connections Electrical: DIN 43650 connector (standard) Pressure: G1/2 (standard)
Protection rating (EN 60529) Standard: IP65
Vibration resistance (IEC 68-2-6) BH version: 2.5 mm (5 - 20 Hz) / 5 g (20 to 1000 kHz)
The E8900 is created by the use of a stainless steel pressure gauge – Ø63, 100, 150 or 160 mm – and the E910* pressure transmitter.
It has been designed for all industrial applications to allow both a local pressure reading and remote signal transmission to a Programmable Logic Controller or other computer-based system.
* See leaflet: A11.03.UK
Design and specifications subject to change without noticeData sheet A11.09
Design and specifications subject to change without noticeData sheet A11.09www.bourdon-haenni.com
Page 3
Access to adjustments
E8930 - pressure gauge Ø 63 mmMicro DIN 43650C connector as standard
TYPE D
= 0.380kg
Dimensions (mm), weight
TYPE D
= 0.900kg
TYPE F
E8950 - pressure gauge Ø 100 mmDIN 43650 connector as standard
= 0.900kg
A=
110
G1/2
91
Ø6...835
79
Ø101
A=
109
50.5
35 Ø6...8
9319
31.5
Ø101
Electrical connection A
DIN 43650 connector 110
DIN 43650C micro plug (option 08) 108
Pig tail + PG7 cable gland (option 23) 101
Terminal strip outlet +screwed cap (option 20) 121
Electrical connection A
DIN 43650 connector 109
DIN 43650C micro plug (option 08) 107
Pig tail + PG7 cable gland (option 23) 100
Terminal strip outlet + screwed cap (option 20) 120
Design and specifications subject to change without noticeData sheet A11.09www.bourdon-haenni.com
Page 2 Design and specifications subject to change without noticeData sheet A11.09
A=
110
G1/2
B=
100
D= 95
35
C= Ø150
Ø6...8
TYPE D
= 1.200kg
TYPE F
E8970 - pressure gauge Ø 150 mmDIN 43650 connector as standard
= 1.200kg
Electrical connection A
DIN 43650 connector 110
DIN 43650C micro plug (option 08) 108
Pig tail + PG7 cable gland (option 23) 101
Terminal strip outlet +screwed cap (option 20) 121
E8980 - pressure gauge Ø 160 mmDIN 43650 connector as standard
A=
109
C= Ø150
B= 97.5
19
35 Ø6...8
31.5
A = 110B = 105C = Ø 160D = 95
A = 109B = 97,5C = Ø 160
TYPE D TYPE F
= 1.300kg
= 1.300kg
Dimensions (mm), weight
Electrical connection A
DIN 43650 connector 109
DIN 43650C micro plug (option 08) 107
Pig tail + PG7 cable gland (option 23) 100
Terminal strip outlet + screwed cap (option 20) 120
Connections
E/Y89X3 E/Y89X2/4/6
1 +Supply + Meas.
2 - Supply - Meas./-Supply
3 + Supply
Ground Ground
Connector DIN and Micro DIN
E/Y89X3 E/Y89X2/4/6
White +Supply
Blue - Supply - Meas./-Supply
Red +Supply
Yellow + Meas
Screen
Cable outlet + cable gland PG7
Design and specifications subject to change without noticeData sheet A11.09
Range
* pressure gauge
Compound pressure -1+0 -1+0.6 -1+1.5 -1+3 -1+5 -1+9 -1+15 -1+24 - - - - - -
Pressure 1 1.6 2.5 4 6 10 16 25 40 60 100 160 250 400
Max. over pressure* 1.3 3 4 8 12 20 32 50 80 120 200 320 500 600
Options
Model 1´...3´ digitStandard Intrinsically safe
Dial diameter 4´ digitØ 63Ø 100Ø 150Ø 160
Output signal 5´ digit0...10 Vdc4...20 mA standard1...5 Vdc0...20 mA
Type of mounting 6´ digitBottom connection (Ø 63 - 100 - 150 - 160 mm)Back connection (Ø 100 - 150 - 160 mm)
Hydraulic connection 7´...8´ digitG 1/4 (standard Ø 63 mm)G 1/2 (standard Ø 100 - 150 - 160 mm)1/4 NPT1/2 NPT
Cell O'Ring 9´ digitNBR (nitril) standard
Type of liquid filling 10´ digitDryBH1 filling (-20...+70°C)BH3 filling (-25...+85°C)
Pressure range 11´...13´ digitSee codes in tables
x89xx xxxxx xxx
E89Y89
3 5 7 8
2 3 4 6
D F
02 03 05 06
3
0 1 3
xxx
Measuring Ranges (bar)
Ordering Details - E8900
B59B72B74B76B77B79B81B82B15B16B18B19B20B22B24B26B27B29B31B33B35B38
code
-1 + 0 x x x x-1 + 0.6 x x x x-1 + 1.5 x x x x-1 + 3 x x x x-1 + 5 x x x x-1 + 9 x x x x-1 + 15 x x x x-1 + 24 x x x x 0 + 1 x x x x 0 + 1.6 x x x x 0 + 2.5 x x x x 0 + 4 x x x x 0 + 6 x x x x 0 + 10 x x x x 0 + 16 x x x x 0 + 25 x x x x 0 + 40 x x x x 0 + 60 x x x x 0 + 100 x x x x 0 + 160 x x x x 0 + 250 x x x x 0 + 400 x x x x
Range in Bar Ø du manomètre 63 100 150 160
Uncoded Options (have to be listed after the code) Coded Options
Lightning protectionSupply voltage (high/low)(1)
Ambient temperature (high/low)(1)
Compensated temperature range (- 10...+70°C)Zero thermal drift: ±0.015% of range/°C max.Calibration of sensor with certificate: Q1060B type of mounting (back connection + flange) for Ø100, 150 and 160 mmOther units: kPa (code D), MPa (code E), kg/cm² (code F), psi (code H), mbar (code N) Mounting on chemical seals : please call usOther : please call us
Other electrical connections: 08. DIN 43650C micro plug (IP65 (2)) 23. Pig tail (1.5 m) + PG7 cable gland (IP65, IP67 (3)) 20. Terminal strip outlet + screwed cap (IP65, IP67)
(1) see specifications for details / (2) IP65: water spray / (3) IP67: temporary immersion
UK/
2002
-10
Thi
s da
ta s
heet
may
onl
y be
repr
oduc
ed in
full
D6.146 E / 1.01Design and specifications subject to change without notice
Compact Pressure Transmitter ED 505
Application Measurement of gauge pressure of gases and liquids for machinery in heating, air conditioning and sanitary applicationscertified for marine applications (Bureau VeritasType approval)
Construction Compact and rugged execution in stainless steel
Pressure range 1 bar … 400 bar
Output signal 4 … 20 mA
Static error band 0,5% FS typ. (VDI/VDE 2184)
Electrical connection Plug, cable (cable socket, see D6.911 D)
Pressure connection Male thread G1⁄2, G1⁄4, DIN 16288Male thread G1⁄2 DIN 3852 and others
Type of protection IP 65
EMC Protected for industrial environments, according to EN-50081-1 and EN 50082-2
1) Only ≤ 25 bar abs2) Other O-ring seal on request, see D6.901 D, for medium temperature <–20˚C, select EPDM ring.
Accessories see D6.911 D
Electrical connection (Pin assignments and cable colours see D0.320 D)
IA = 4 ... 20 mA
Ordering example: ED 505 / 3 1 4 . 2 1 1 / 075
System design ED 505Pressure type Gauge pressure 3
Absolute pressure1) 4Static error band 0,5% FS max. (Tmed = 25˚C) 1Electrical connect. Cable 2 m 1
Plug DIN 43650 4Output signal IA = 4 … 20 mA 2Pressure connect. Male thread G1⁄2 DIN 16288, stainless steel 1.4305 1
Male thread G1⁄4 DIN 16288, stainless steel 1.4305 2Male thread M20x1,5 DIN 16288, stainless steel 1.4305 3Male thread G1⁄2 DIN 3852, stainless steel 1.4305 4Male thread 1⁄2"-14 NPT, stainless steel 1.4305 6Male thread G1⁄4 DIN 3852, stainless steel 1.4305 7Female thread G1⁄4, stainless steel 1.4305 8Male thread 7/16–20 UNF, stainless steel 1.4305 AMale thread 1⁄4" NPT, stainless steel 1.4305 B
Diaphragm(parts in contact Diaphragm ceramicwith medium) O-ring seal FPM (Viton)2) 1Pressure range
Order Pressurecode range
bar
025 0 … 1
035 0 … 1,6
A15 0 … 2
045 0 … 2,5
055 0 … 4
A25 0 … 5
065 0 … 6
075 0 … 10
085 0 … 16
A35 0 … 20
095 0 … 25
105 0 … 40
A45 0 … 50
Order Pressurecode range
bar
125 0 … 100
135 0 ... 160
A55 0 … 200
145 0 ... 250
155 0 … 400
H05 -1 … 1
515 -1 … -1,5
F05 -1 … 2
525 -1 … 3
535 -1 … 5
545 -1 … 9
315 -1 … 0
Selection Chart
S._15-20_Kat.Elekt.E 17.01.2001 14:04 Uhr Seite 15
D6.146 E / 1.01Design and specifications subject to change without notice
Compact Pressure Transmitter ED 505
Construction and FunctionThe pressure transmitter ED 505 Compact has been designedto be used in general purpose application for pressure range of1 to 400 bar. It is also possible to shift the zero point into thevacuum (e.g. to –1 bar). Special efforts were made to the con-struction to allow use under harsh conditions.
The transmitter consists of a stainless steel housing into whicha ceramic pressure sensor, the electronics and the electricalconnection is built in. For standard industrial EMC environ-ments, the connection DIN 43650 is sufficient; however, for verytough conditions, we recommend to use the version with adirect cable.
Pressure range p = 0 … +P bar 1 … 400p = -1 … +P bar -1 … 9
Maximum static pressure bar 1,5 x pressure rangeBurst pressure bar 2 x pressure rangeDeviation of characteristic curve (DIN 16086) ± % FS < 0,5 typ(Tamb = 25° C)Hysteresis and reproducibility ± % FS < 0,1TC zero point (0 …50° C) ± % FS/10 K < 0,4 typTC sensitivity (0 …50° C) ± % FS/10 K < 0,25 typResponse time (10 … 90%) ms ≤ 1Operating temp. (medium) °C -50 … 801)
Housing temperature °C -15 … 801)
Storage temperature °C -40 … 801)
Supply voltage UB 4 … 20 mA V DC 10 … 30Reverse polarity protection for supply UB yesShort circuit proof output yesOvervoltage protection yesLoad (RL+RLine) at 4 … 20 mA Ohm < 1000 (see diagram D0.320 D)Type of protection (DIN 40 050, IEC 144) according selection chartEMC emission (EN 50 081 –1) fulfilledEMC immunity (EN 50 082 –2) fulfilled
IEC 1000–4–2 / EN 61000–4–2 level 3 (8 kV) fulfilledIEC 1000–4–3 / ENV 50140 level 3 (10 V/m) fulfilledIEC 1000–4–4 / EN 61000–4–4 level 4 (4 kV) fulfilledIEC 1000–4–6 / ENV 50141 level (10 V) fulfilled
Vibration test DIN IEC 68 fulfilledTest of load cycles cycles > 1 millionWeight kg ca. 0,2
Technical Data
1) At p abs max. 70°C
Pressure port d l1 l2
G1⁄2 DIN 16288G1⁄4 DIN 16288
M20x1.5 DIN 16288G1⁄2 ’’ DIN 3852
1⁄2 ’’- 14NPTG1⁄4 ’’ DIN 3852G1⁄4 ’’ Female7/16’’-20UNF
1⁄4’’-NPT
656––––––
201320142212
17.513.513
535––––––
Cable
G1⁄4 DIN 16288DIN 43650
G1⁄4 DIN 3852
G ⁄4’’ Female
M20x1.5 DIN 16288
G 1⁄2
l 2l 1
49
SW 27
d
G1⁄2’’ DIN 3852
7⁄16’’-20UNF
1⁄2’’14NPT
1⁄4’’ NPT
S._15-20_Kat.Elekt.E 17.01.2001 14:04 Uhr Seite 16
D6.150.1 E / 1.01Design and specifications subject to change without notice
Ordering example: ED 510 / 3 1 4 . 2 1 1 / 155
System design EDX 510EEx ia II C (ATEX)3) EDX 510
Pressure type Gauge pressure 3Absolute pressure 4
Static error band 0,4% FS (Tmed = 25˚C), comp. temp. range -00 … 50°C 1(Tamb = 25˚C) 0,2% FS (Tmed = 25˚C), comp. temp. range -10 … 50°C 2
0,4% FS (Tmed = 25˚C), comp. temp. range -10 … 80°C 40,2% FS (Tmed = 25˚C), comp. temp. range -10 … 80°C 50,4% FS (Tmed = 75˚C), comp. temp. range -50 …100°C 70,4% FS (Tmed = 100˚C), comp. temp. range -75 …125°C 8
Electrical connect. Cable 2 m IP 65 1Plug Fischer1) IP 67 2Plug DIN 41 524 (Binder) IP 65 3Plug DIN 43 650 IP 65 4Cable 2 m IP 67 9
Output signal IA = 0 … 20 mA 1IA = 4 … 20 mA 2UA = 0 … 10 V DC 4UA = 0 … 5 V DC 5
Pressure connect. Male thread G1⁄2 DIN 16 288, stainless steel 1.4435 1Male thread G1⁄4 DIN 16 288, stainless steel 1.4435 2Male thread M20 × 1,5 DIN 16 288, stainless steel 1.4435 3Male thread G1⁄2 DIN 3852 (virtually flush diaphragm), st. steel 1.4435 4Male thread G1⁄8 DIN 16 288 stainless steel 1.4435 5Male thread 1⁄2" NPT (virtually flush diaphragm), stainless steel 1.4435 6Female thread G1⁄4 DIN 3852, stainless steel 1.4435 7Female thread NPT 1⁄4 –18, stainless steel 1.4435 8
Diaphragm Stainless steel 1.4404/316 L 1Hastelloy C-276 2Stainless steel, gold plated2) 9
Pressure range also other pressure ranges and versions in Pa, psi, H2O etc. available
Order Pressurecode range
mbar126 0 … 100136 0 … 160A56 0 … 200
146 0 … 250156 0 … 400A66 0 … 500166 0 … 600
bar025 0 … 1035 0 … 1,6A15 0 … 2
045 0 … 2,5055 0 … 4A25 0 … 5065 0 … 6
075 0 … 10085 0 … 16A35 0 … 20
095 0 … 25105 0 … 40A45 0 … 50
115 0 … 60125 0 … 100135 0 … 160
A55 0 … 200145 0 … 250155 0 … 400
Order Pressurecode range
mbarD06 -100 … -100D26 -100 … -200D56 -100 … -500
H66 -100 … -100H76 -200 … -200H86 -500 … -500
barD85 -0 … -1H05 -1 … -1525 -1 … -3
535 -1 … -5545 -1 … -9
Standard Industrial Pressure Transmitter ED 510
Selection Chart
Application Measurement of gauge and absolute pressureof gases and liquids with normal or highermedium temperatures
Construction Rugged industrial execution in stainless steelZero point and span adjustment
Pressure range 100 mbar … 400 bar
Output signal 0 … 20 mA, 4 … 20 mA,0 … 5 V DC, 0 … 10 V DC
Static error band ≤ 0,25% FS typ., ≤ 0,15% FS typ.
Electrical connection Cable or plug
Pressure connection Male thread G1⁄2, G1⁄4, G1⁄8 DIN 16 288Male thread M20 × 1,5 DIN 16 288Male thread G1⁄2 DIN 3852, O-Ring NBRMale thread 1⁄2" NPTFemale thread G1⁄4" DIN 3852Female thread NPT 1⁄4–18
Type of protection IP 65, IP 67
EMC Protected for industrial environments, conforming to EN 50081-2, EN-50081-1 and EN 50082-2
Accessories Test certificate included
1) Cable socket connector included2) Version ED 510/xxx.x4x and ED 510/xxx.x6x only, max. range 20 bar3) Version 4 … 20 mA only
Special Designs see D6.901 E / Accessories see D6.911 E
S._15-20_Kat.Elekt.E 17.01.2001 14:04 Uhr Seite 17
D6.150.1 E / 1.01Design and specifications subject to change without notice
Pressure range 1 0 … +P bar
Maximum pressure P max. bar
Pressure range 2 –P … 0/–P … 0 … +P bar
Maximum pressure P max. bar
Deviation of characteristic ED 510/x1, x4, x7 und x8 ± % FS ≤ 0,25 typ./0,4 max. (see diagram D0.320)curve (Tamb = 25°C) ED 510/x2, x5 ± % FS ≤ 0,15 typ./0,2 max. (see diagram D0.320)
Hysteresis and reproducibility ± % FS ≤ 0,2 (p < 0,4 bar) / 0,1 (p ≥ 0,4 bar)
TC zero point pressure range 1 ± % FS/10 K ≤ED 510/x1, x2, x7, x8 pressure range 2 ± % FS/10 K ≤TC zero point pressure range 1 ± % FS/10 K ≤ED 510/x4, x5 pressure range 2 ± % FS/10 K ≤TC sensitivity ± % FS/10 K ≤ 0,25
Operating temp. (medium) °C according selection chart
Housing temperature °C –20 … 80
Storage temperature °C –40 … 80
Supply voltage UB IA = 0 … 20 mA V DC –16 … 30
IA = 4 … 20 mA V DC –10 … 30
UA = 0 … 5 V DC V DC –09 …30
UA = 0 … 10 V DC V DC –14 … 30
Reverse polarity protection for supply voltage UB yes
Short circuit proof output yes
Overvoltage protection yes
Load (RL + RLine) IA = 0 … 20 mA Ohm ≤ 500
IA = 4 … 20 mA Ohm ≤ 1000 (diagram D0.320)
UA = 0 … 5 V DC kOhm ≥ 5
UA = 0 … 10 V DC kOhm ≥ 10
Zero point adjusting range ± % FS 2
Insulation resistance at 750 V DC MOhm ≥ 1,2
Type of protection (DIN 40 050, IEC 144) according selection chart
EMC emission (EN 50 081-1 and -2) fulfilled
EMC immunity (EN 50 082-2) fulfilled
IEC 1000-4-2 / EN 61000-4-2 level 3 (8 kV) fulfilled
IEC 1000-4-3 / ENV 50140 level 3 (10 V/m) fulfilled
IEC 1000-4-4 / EN 61000-4-4 level 4 (4 kV) fulfilled
IEC 1000-4-6 / ENV 50141 level (10 kV) fulfilled
Vibration test DIN IEC 68 fulfilled
Test of load cycles cycles ≥ 10 millions
Weight kg 0,25
1,0
1,0
1,5
1,5
0,6
0,6
1,0
1,0
0,4
0,4
0,6
0,6
0,3
0,3
0,3
0,3
0,3
0,8
0,3
1,0
0,25
0,5
0,3
0,6
0,25
0,3
0,3
0,3
0,25
0,3
0,3
0,3
0,25
0,3
0,25
0,3
0,25
0,25
0,25
0,3
0,25
0,25
0,25
0,3
Standard Industrial Pressure Transmitter ED 510
Technical Data
Construction and FunctionPressure transmitter ED 510 consists of a pressure connection sectionwith welded stainless steel (or Hastelloy) diaphragm and a stainlesssteel case for housing the electronic circuit and the electrical connec-tion. The piezoresistive pressure sensor is mounted right behind thediaphragm. The pressure being measured is transmitted by the externaldiaphragm and the silicon oil filling to the measuring diaphragm of thepiezoresistive silicon sensor. An amplifier converts the pressure sensor’sbridge to the desired signal level. The amplifier space is sealed toprovide optimal shock and vibration resistance.
The transmitters with a pressure connection similar to DIN 16 288 aresealed before the thread with a washer according to DIN 16 258. Thetransmitters with pressure connection similar to DIN 3852 are sealedbehind the thread with an O-ring (no flush-mounted sealing).Access to the adjusting potentiometer is obtained by unscrewingthe closure ring. Both zero point and span can be adjusted with ascrewdriver.
0,1
4
0…–0,1
4
0,16…0,25
4
0…–0,2
4
0,4…0,6
6
0…–0,5
6
1…1,6
10
0…–1
10
2…4
15
–0,1…0,1
4
5…10
30
–0,2…0,2
4
16…25
75
–0,5…0,5
6
40…60
100
–1…1
10
100…160
250
–1…3
15
200…400
600
–1…5
30
–1…9
30
Electrical Connection (Pin assignments and cable colours see D0.320 D)
IA = 4 … 20 mA IA = 0 … 20 mA, UA = 0 … 5 V, UA = 0 … 10 V
S._15-20_Kat.Elekt.E 17.01.2001 14:04 Uhr Seite 18
Design and specifications subject to change without notice D6.150.2 E / 1.01Design and specifications subject to change without notice
Standard Industrial Pressure Transmitter ED 510
Thread Washerd1 d2 d3 d4 b t1 t2 I1 I2 I3
+ 0,5 S DIN 16 258
G1⁄4 5 9,5 5,5 6,5 10 14 12 3 2 14 form A
G1⁄2 6 17,5 7,0 13,5 18 24 20 5 3 22 form B
M20 1,5 6 17,5 7,0 14,5 18 24 20 5 3 22 form B
Connection according to DIN 16 288
Male connectorfor flat sealing
Screw hole with thread
Thread countersunk up to outer diameter
Mounted connector
Maleconnector
Screw hole
Washer
I1 100
30,5
I1 104 35
17
18,5 SW 27 SW 2718
100
122 122
58 23 98
Seal
M20
1,
5G
1 ⁄ 2, G
1 ⁄ 4, G
1 ⁄ 8
M20
1,
5G
1 ⁄ 2, G
1 ⁄ 4, G
1 ⁄ 8
G1 ⁄4
’’
1 ⁄ 4’’
NP
T1 ⁄2"
NP
T
DIN 3852 DIN 41 524 NPT Kabel
DIN 3852 DIN 41 524 NPT Cable
Dimensions
DIN 16 288 DIN 43 650 DIN 16 288 Fischer
G1 ⁄2
27 mm Hex.
27 mm Hex.
27 mm Hex. 27 mm Hex.
27 mm Hex.
27 mm Hex.
S._15-20_Kat.Elekt.E 17.01.2001 14:04 Uhr Seite 19
D6.153 E / 1.01Design and specifications subject to change without notice
Ordering example: ED 513 / 3 1 4 . 2 1 1 / 155
System design EDX 513EEx ia II C (ATEX)3) EDX 513
Pressure type Gauge pressure 3Absolute pressure 4
Static error band 0,4% FS (Tmed = 25°C), comp. temp. range 0 … 50°C 1(Tamb = 25˚C) 0,2% FS (Tmed = 25°C), comp. temp. range 0 … 50°C 2
0,4% FS by adjusted temperature1) 70,2% FS by adjusted temperature1) 8
Electrical connect. Cable 2 m IP 65 1Plug Fischer2) IP 67 2Plug DIN 41 524 (Binder) IP 65 3Plug DIN 43 650 IP 65 4
Output signal IA = 0 … 20 mA 1IA = 4 … 20 mA 2UA = 0 … 10 V DC 4UA = 0 … 5 V DC 5
Pressure connect. Male thread G1⁄2 DIN 3852, stainless steel 1.4435 1Diaphragm Stainless steel 1,4404/316 L 1
Hastelloy C-276 2Pressure range Also other pressure ranges and versions in Pa, psi, H2O etc. available
Order- Pressurecode range
mbar126 0 … 100136 0 … 160A56 0 … 200
146 0 … 250156 0 … 400A66 0 … 500166 0 … 600
bar025 0 … 1035 0 … 1,6A15 0 … 2045 0 … 2,5055 0 … 4A25 0 … 5065 0 … 6
075 0 … 10085 0 … 16A35 0 … 20
095 0 … 25105 0 … 40A45 0 … 50
115 0 … 60125 0 … 100135 0 … 160
A55 0 … 200145 0 … 250155 0 … 400
Order- Pressurecode range
mbarD06 -100 … -100D26 -100 … -200D56 -100 … -500
H66 -100 … -100H76 -200 … -200H86 -500 … -500
barD85 -0 … -1H05 -1 … -1525 -1 … -3535 -1 … -5545 -1 … -9
Industrial Pressure Transmitter for High Temperature ED 513
Selection Chart
1) Adjusted temperatureIf the adjustment of the medium is above 25°C, the temperature must be advised with the order code /9007/XXXX.Ordering example: adjustment at 150°C, order code /9007/0150.The compensated temperature range is ± 25°C of the adjusted temperature. If the adjusted temperature is above 175°C, the compensated range will always be 150°C to 200°C.2) Cable socket connector included.3) Version 4 ... 20 mA only
Special Designs see D6.901 E / Accessories see D6.911 E
Application Measurement of absolute and relative pressure of gases and liquids for temperatures up to 200°C
Construction Rugged industrial version in stainless steel.Zero point and sensitivity adjustable
Pressure range 100 mbar … 400 bar
Output signal 0 … 20 mA, 4 … 20 mA,0 … 5 V DC, 0 … 10 V DC
Medium temperature –40 … 200°C
Static error band ≤ 0,25% FS typ., ≤ 0,15% FS typ.
Electrical connection Plug or cable
Pressure connection Male thread G1⁄2 DIN 3852O-Ring-/Silcoflon PFA, Nitril NBR, Viton FPM
Type of protection IP 65, IP 67
EMC Protected for industrial environments, conforming to EN 50081-2, EN 50081-1and EN 50082-2
Accessories Test certificate
Electrical Connection (Pin assignments and cable colours see D0.320 E)IA = 4 … 20 mA IA = 0 … 20 mA, UA = 0 … 5 V, UA = 0 … 10 V
S._21-24_Kat.Elekt.E 17.01.2001 14:11 Uhr Seite 21
D6.153 E / 1.01Design and specifications subject to change without notice
p (bar) L (mm)
0.1 ... ≤ 10 171
<10 ... 400 179
Pressure range 1 0 … +P bar
Maximum Pressure P max. bar
Pressure range 2 –P … 0/–P … 0 … +P bar
Maximum Pressure P max. bar
Deviation of characteristic ED 513/x1 ± % FS ≤ 0,25 typ./0,4 max. (see diagramm D0.320)
curve (Tmed = 25°C) ED 513/x2 ± % FS ≤ 0,15 typ./0,2 max. (see diagramm D0.320)
Hysteresis and reproducibility ± % FS ≤ 0,2 (p < 0,4 bar) / 0,1 (p ≥ 0,4 bar)
TC zero point1) pressure range 1 ± % FS/10 K ≤pressure range 2 ± % FS/10 K ≤
TC sensitivity1) ± % FS/10 K ≤ 0,25
Operating temp. (medium) °C –40 … 200 (see diagram medium pressure)
Housing temperature °C –20 … 80
Storage temperature °C –40 … 80
Supply voltage UB IA = 0 … 20 mA V DC –16 … 30
IA = 4 … 20 mA V DC –10 … 30
UA = 0 … 5 V DC V DC –09 … 30
UA = 0 … 10 V DC V DC –14 … 30
Reverse polarity protection for supply UB yes
Short circuit proof output yes
Overvoltage protection yes
Load (RL + RLine) IA = 0 … 20 mA Ohm ≤ 500
IA = 4 … 20 mA Ohm ≤ 1000 (see diagram D0.320)
UA = 0 … 5 V DC kOhm ≥ 5
UA = 0 … 10 V DC kOhm ≥ 10
Zero point adjusting range ± % FS 2
Insulation resistance at 750 V DC MOhm ≥ 1,2
Type of protection (DIN 40 050, IEC 144) according selection chart
EMC emission (EN 50 081-1 and 2) fulfilled
EMC immunity (EN 50 082-2) fulfilled
IEC 1000-4-2 / EN 61000-4-2 level 3 (8 kV) fulfilled
IEC 1000-4-3 / ENV 50140 level 3 (10 V/m) fulfilled
IEC 1000-4-4 / EN 61000-4-4 level 4 (4 kV) fulfilled
IEC 1000-4-6 / ENV 50141 level (10 kV) fulfilled
Weight kg 0,35
1,8
1,8
1,0
1,0
0,3
1,0
0,3
0,3
0,3
0,3
0,25
1,0
0,25
0,8
0,25
0,5
0,25
0,3
0,25
0,3
0,25
0,3
Industrial Pressure Transmitter for High Temperature ED 513
Technical Data
Construction and Function
Dimensions Ambient Temperature Medium pressureAllowed Ambient Temp. Range Admissible medium pressure as aas a function of medium temp. function of medium temperature
The pressure transmitter ED 513 consists of a pressure connection body pro-vided with cooling radiator and a welded stainless steel or hastelloy dia-phragm and a stainless steel case to house the electronic circuitry and theelectrical connection. The piezoresistive pressure sensor is mounted withinthe body of the transmitter and separated from the diaphragm by the trans-mission/cooling oil.The pressure being measured is transmitted from the diaphragm and thetransmission liquid to the piezoresistive silicon sensor.An amplifier converts the pressure sensor’s bridge signal to the desired level.The amplifier and associated electronics are encapsulated to give an optimalprotection against shock and vibration.
The pressure transmitter is designed with a G1⁄2 pressure connection similarto DIN 3852. The sealing is provided at the thread with an O-ring, speciallydesigned for high temperatures.Electrical connection with plug DIN 43 650 and cable: For the adjustment ofthe zero point and span, the two potentiometers are accessible after unscre-wing the ring under connector. The zero point and span can be adjustedexternaly with a screw-driver.Electrical connection with round plug IP 67: The potentiometers for zero pointand span are accessible from externally.
0,1
4
0…–0,1
4
0,16…0,25
4
0…–0,2
4
0,4…0,6
6
0…–0,5
6
1…1,6
10
0…–1
10
2…4
15
–0,1…0,1
4
5…10
30
–0,2…0,2
4
16…25
75
–0,5…0,5
6
40…60
100
–1…1
10
100…160
250
–1…3
15
200…400
600
–1…5
30
–1…9
30
1) Calibration temperature ±25°C
–0,5 bar
0 bar
p rel
–1 bar
prohibitedzone
Medium pressure
pabs
1 bar
0,5 bar
1 mbar0–50 0 100 200 Medium
temperature °C
Joint
S._21-24_Kat.Elekt.E 17.01.2001 14:11 Uhr Seite 22
D6.158.1 E / 1.01Design and specifications subject to change without notice
Ordering example ED 518 / 3 1 4 . 2 9 1 / 075
System design EDX 518EEx ia II C (ATEX)4) EDX 518
Pressure type Gauge pressure 3Absolute pressure 4
Static error band1) 0,4% FS (Tmed = 25˚C), comp. temp. range 0 … 50°C 1(Tamb = 25˚C) 0,2% FS (Tmed = 25˚C), comp. temp. range 0 … 50°C 2Electrical connect. Cable 2 m IP 65 1
Plug Fischer 3) IP 67 2Plug DIN 41 524 (Binder) IP 65 3Plug DIN 43 650 IP 65 4Cable 2 m IP 67 9
Output signal IA = 0 … 20 mA 1IA = 4 … 20 mA 2UA = 0 … 10 V DC 4UA = 0 … 5 V DC 5
Pressure connect. Male thread G1⁄2 DIN 16 288 1Male thread G1⁄4 DIN 16 288 2Connection for separator 2) 9
Pressure connect.material Stainless steel 1.4435 1Pressure range also other pressure ranges and versions in Pa, psi, H2O etc. available
Order Pressurecode range
bar025 0 … 1035 0 … 1,6A15 0 … 2
045 0 … 2,5055 0 … 4A25 0 … 5
065 0 … 6075 0 … 10085 0 … 16A35 0 … 20
095 0 … 25105 0 … 40A45 0 … 50
Order PressureOrder range
bar115 0 … 60125 1 … 100135 0 … 160
A55 0 … 200145 0 … 250155 0 … 400
D85 -0 … -1H05 -1 … -1525 -1 … -3
535 -1 … -5545 -1 … -9
Pressure Transmitter for Assembly with Separator ED 518
Selection Chart
1) without separator 2) Connection will be defined by HAENNI 3) cable socket connector included 4) Version 4 … 20 mA only
Special Designs see D6.901 E / Accessories see D6.911 E
Application Measurement of gauge and absolute pressure for gases and liquids with assembledseparator
Construction Rugged industrial execution in stainless steelZero point and span adjustment
Pressure range 1 … 400 bar
Output signal 0 … 20 mA, 4 … 20 mA,0 … 5 V DC, 0 … 10 V DC
Static error band ≤ 0,25% FS typ., ≤ 0,15% FS typ.
Electrical connection Cable or plug
Pressure connection see catalog sheets of separator
Type of protection IP 65, IP 67
EMC Protected for industrial environments, conforming to EN 50081-2, EN 50081-1 andEN 50082-2
Accessory Test certificate
Electrical Connection (Pin assignments and cable colours see D0.320 E)
IA = 4 … 20 mA IA = 0 … 20 mA, UA = 0 … 5 V, UA = 0 … 10 V
S._25-30_Kat.Elekt.E 17.01.2001 14:17 Uhr Seite 25
D6.158.1 E / 1.01Design and specifications subject to change without notice
Pressure range 0 … +P bar
Maximum Pressure P max. bar
Deviation of characteristic ED 518/x1 ± % FS ≤ 0,25 typ./0,4 max. (see diagram D0.320)curve (Tamb = 25°C) ED 518/x2 ± % FS ≤ 0,15 typ./0,2 max. (see diagram D0.320)
Hysteresis and reproducibility ± % FS ≤ 0,1
TC zero point (ED 518 only) ± % FS/10 K ≤TC sensitivity (ED 518 only) ± % FS/10 K ≤ 0,3
Operating temp. (medium) com./not comp. °C 0 … 50
Housing temperature °C –20 … 80
Storage temperature °C –40 … 80
Supply voltage UB IA = 0 … 20 mA V DC –16 … 30
IA = 4 … 20 mA V DC –10 … 30
UA = 0 … 5 V DC V DC –09 … 30
UA = 0 … 10 V DC V DC –14 … 30
Reverse polarity protection for supply UB yes
Short circuit proof output yes
Overvoltage protection yes
Load (RL + RLine) IA = 0 … 20 mA Ohm ≤ 500
IA = 4 … 20 mA Ohm ≤ 1000 (see diagram D0.320)
UA = 0 … 5 V DC kOhm ≥ 5
UA = 0 … 10 V DC kOhm ≥ 10
Zero point adjusting range ± % FS 2
Insulation resistance at 750 V DC MOhm ≥ 1,2
Type of protection (DIN 40 050, IEC 144) IP 65, IP 67
EMC emission (EN 50 081-1 and -2) fulfilled
EMC immunity (EN 50 082-2) fulfilled
IEC 1000-4-2 / EN 61000-4-2 level 3 (8 kV) fulfilled
IEC 1000-4-3 / ENV 50140 level 3 (10 V/m) fulfilled
IEC 1000-4-4 / EN 61000-4-4 level 4 (4 kV) fulfilled
IEC 1000-4-6 / ENV 50141 level (10 kV) fulfilled
Test of load cycles cycles ≥ 10 millions
Weight kg 0,16
0,3
Technical Data
Construction and Function
1…1,6
10
2…4
15
5…10
3016…25
75
40…60
100
100…160
250
200…400
600
0,3 0,3 0,3 0,3 0,3 0,3
Industrial Pressure Transmitter for Assembly with Separator ED 518
The Pressure transmitter ED 518 consists of a pressure connectionsection fix assembled with a separator and a stainless steel case forhousing the electronic circuit. The piezoresistive pressure sensor ismounted in the pressure connection section. The pressure being mea-sured is transmitted by the external diaphragm and the transmissionliquid (normally silicon oil, other liquids for special applications are avai-lable) to the measuring diaphragm of the piezoresistive silicon sensor.An amplifier converts the pressure sensor’s bridge to the desired signal
level. The amplifier space is sealed to provide optimal shock and vibra-tion resistance.The pressure connection of the pressure transmitter is in conformity withthe assembled separator.The ED 518 is provided with 2 potentiometers for the adjustment ofthe zero point and of span. Access to the adjusting potentiometer isobtained by unscrewing the closure ring, or at the IP 67 version theoutside.
Dimensions
Thread L1
G1⁄2 20
G1⁄4 13
Separator dimensionssee catalog «Separators»
I1 100
G1 ⁄4
, G1 ⁄2
30,5
DIN 16 288 DIN 43 650
S._25-30_Kat.Elekt.E 17.01.2001 14:17 Uhr Seite 26
D6.158.2 E / 1.01Design and specifications subject to change without notice
Synoptical table of separators
Industrial Pressure Transmitter for Assembly with Separator ED 518
Separator type Ordering code TC separator TC capillary1)
%/10 K %/10 Kat range 1 bar2) at range 1 bar2)
Diaphragm separator series 1020 1020–1022 0,4 0,2Diaphragm separator series 1030 1031–1042 0,3 0,1
1045–1046 on request on requestDiaphragm separator series 1060 1061–1062 2,0 2,6
1063–1064 1,9 2,61065–1066 2,0 2,6
Diaphragm separator series 1080 1081 0,9 0,71085–1086 2,0 2,8
Diaphragm separator series 1090 1091–1092 0,5 0,51093–1094 0,6 0,3
Diaphragm separator series 1100 + 1140 1107 2,0 2,81101 1,7 1,3
1103–1143 0,6 0,31105–1145 0,3 0,2
1109 0,3 0,11111 0,2 0,1
Diaphragm separator series 1470 1475 0,9 0,91476 0,6 0,51477 0,6 0,51471 0,3 0,11487 0,2 0,051473 0,1 0,011479 0,1 0,011481 0,05 0,02
Tongue design separator series 1500 1501–1502 2,1 1,2Tongue design separator series 1510 1511–1514 2,1 1,2Pipe separator series 1530 1531 0,2 0,2
1532 0,7 0,61537 0,7 0,51534 0,3 0,31533 0,1 0,11536 0,2 0,11535 0,1 0,11539 0,2 0,1
Pipe separator series 1540 1547 1,0 2,01541 0,1 0,21545 0,3 0,31542 0,5 0,41543 0,4 0,31544 0,1 0,11546 0,2 0,1
Pipe separator series 1620 1627 1,0 2,01621 0,1 0,21622 0,2 0,21623 0,4 0,31624 0,2 0,11625 0,2 0,11626 0,3 0,1
Pipe separator series 1650 1653 0,3 0,41655 0,2 0,11656 0,1 0,11657 0,3 0,21658 0,2 0,11659 0,2 0,1
Pipe separator series 1660 1663 0,3 0,41665 0,2 0,11666 0,1 0,11667 0,3 0,21668 0,2 0,11669 0,2 0,1
Pipe separator series 1680 1683 0,5 1,91685 0,2 0,21686 0,3 0,31687 0,3 0,31688 0,2 0,21689 0,4 0,4
1) in reference to a capillary of 1 mat ∅ 1 mm. 2) at higher pressure ranges the TC decreases of the range, e.g. at 10 bar of the factor 10.
S._25-30_Kat.Elekt.E 17.01.2001 14:17 Uhr Seite 27
D6.160 E / 1.01Design and specifications subject to change without notice
Electrical Connection (Pin assignments and cable colours see D0.320 E)IA = 4 … 20 mA IA = 0 … 20 mA, UA = 0 … 5 V, UA = 0 … 10 V
Ordering example ED 520 / 3 1 4 . 2 1 1 / 025
System design ED 520EEx ib IIC (ATEX)1) EDX 520
Pressure type Gauge pressure 3Absolute pressure 4
Static error band 0,4% FS (Tmed = 25˚C), comp. temp. -00 … 50°C 1(Tamb = 25˚C) 0,2% FS (Tmed = 25˚C), comp. temp. -10 … 50°C 2
0,4% FS (Tmed = 25˚C), comp. temp. -10 … 80°C 40,2% FS (Tmed = 25˚C), comp. temp. -10 … 80°C 50,4% FS (Tmed = 75˚C), comp. temp. -50 …100°C 70,4% FS (Tmed = 100˚C), comp. temp. -75 …125°C 80,4% FS at specified adjusted temp., Tmax=150°C2)3) A0,2% FS at specified adjusted temp., Tmax=150°C2)3) B
Electrical connect. Cable 2 m IP 654) 1Plug Bendix IP 654) 2Plug DIN 41 524 (Binder) IP 654) 3Plug DIN 43 650 IP 654) 4Cable 2 m with relative tube IP 674) 9
Output signal IA = 0 … 20 mA 1IA = 4 … 20 mA 2UA = 0 … 10 V DC 4UA = 0 … 5 V DC 5
Pressure connect. G 1⁄2 with cone (see selection chart) 1G1 with cone (see selection chart) 2Male thread G1⁄2 DIN 16 288 (available for all pressure ranges)5) 4G 1⁄2 without cone (available for all pressure ranges)5) 8G1 without cone (available for all pressure ranges)5) 9
Diaphragm Stainless steel 1.4404/316 L 1Hastelloy C-276 2Stainless steel, gold plated3) 9
Pressure range also other pressure ranges and versions in Pa, psi, H2O etc. available
Order Pressurecode range
mbar126 0 … 100136 0 … 160A56 0 … 200
146 0 … 250156 0 … 400A66 0 … 500166 0 … 600
bar025 0 … 1035 0 … 1,6A15 0 … 2045 0 … 2,5055 0 … 4A25 0 … 5
065 0 … 6075 0 … 10075 0 … 10
085 0 … 16A35 0 … 20095 0 … 24105 0 … 40
Conn.
G1G1G1
G1G1G1G1
G1G1G1G1G1G1
G1G1G1⁄2
G1⁄2G1⁄2G1⁄2G1⁄2
Conn.
G1⁄2G1⁄2G1⁄2
G1⁄2G1⁄2G1⁄2
G1G1G1G1G1G1
G1G1G1
G1G1
Order Pressurecode range
bar115 -100 … 60125 -100 … 100135 -100 … 160
A55 -100 … 200145 -100 … 250155 -100 … 400
mbarD06 -0 … -100D26 -0 … -200A15 -0 … -500H66 -100 … -100H76 -200 … -200H86 -500 … -500
barD85 -0 … -1H05 -1 … -1525 -1 … -3
535 -1 … -5545 -1 … -9
Pressure Transmitter with Flush Diaphragm ED 520
Selection Chart
1) Version 4 … 20 mA only (with IP 42)2) Temperature adjustments
For temperature adjustments (medium) other than 25°C, the temperature has to be indicated by the order code /9007/xxx. Ordering example: adjustment at 125°C, order code /9007/0125. The compensated temperature range is ± 25°C of the adjusted temperature. If the temperature is above 125°C, the range will always be 100°C to 150°C.
3) Not available for ED 520/xxx.x4x. 4) Not available for EEx. 5) Not available for ED 520/x AB x .xxx
Special Designs see D6.901 E / Accessories see D6.911.1 E
Application Measurement of gauge and absolute pressure forgases and liquids (Level gauging, food industry,sterilizers, pharma industry)
Construction Stainless steel 1.4435 flush diaphragm orconnection acc. DIN 16288.Connection with cone flush metallic sealing (for food application). External zero point andspan adjustment
Pressure range 100 mbar … 400 bar
Output signal 0 … 20 mA, 4 … 20 mA,0 … 5 V DC, 0 … 10 V DC
Static error band ≤ 0,25% FS typ., ≤ 0,15% FS typ.
Electrical connection Cable or plugPressure connection Male thread with cone 1⁄2’’ and 1’’
Male thread without cone 1⁄2’’ und 1’’Male thread G1⁄2’’ DIN 16 288
Type of protection IP 65, IP 67EMC Protected for industrial environments, conforming
to EN 50081-2, EN-50081-1 and EN 50082-2
Accessory Test certificate
S._25-30_Kat.Elekt.E 17.01.2001 14:17 Uhr Seite 29
D6.160 E / 1.01Design and specifications subject to change without notice
B1 C C C DA B B1 ED 520/xAx.xxx Plug Plug Plug Plug
ED 520/xBx.xxx DIN Bendix Binder DING1⁄2 with cone 23 101 119,5 10 20 12 30,5G1 with cone 27 97 121,5 10 20 12 30,5G1⁄2 without cone 20,5 101 119,5 10 20 12 30,5G1 without cone 20,5 97 121,5 10 20 12 30,5G1⁄2 16 288 20 90 119,5 10 20 12 30,5
Pressure Transmitter with Flush Diaphragm ED 520
Construction and Function
Medium pressure Dimension ChartAdmissible medium pressure as a function of medium temperature
Pressure transmitter ED 520 consists of a pressure connection sectionwith welded stainless steel diaphragm and a stainless steel case forhousing the electronic circuit and the electrical connection. The piezore-sistive pressure sensor is mounted directly behind the diaphragm (exceptfor the types ED 520/xAx and ED 520/xBx). For applications with veryaggressive mediums, the cone and diaphragm are gold plated. The pres-sure being measured is transmitted by the external diaphragm and thesilicon oil filling to the measuring diaphragm of the piezoresistive silicon
sensor. An amplifier converts the pressure sensor’s signal to the desiredsignal level. The G1 and G1⁄2 pressure connector with cone makes metal-lic seals and is suitable for food application. For less critical applicationsthe use of other seals are intended.The zero point and span can be adjusted externally by a screwdriver.
Technical Date
Dimensions
Screw hole with thread chamber for DIN 16 288
Mounting example
ED 520/xAx.xxxED 520/xBx.xxx
–0,5 bar
0 bar
p rel
–1 bar
prohibitedzone
Medium pressure
pabs
1 bar
0,5 bar
1 mbar0–50 0 50 100 200 300 Medium temperature °C
120
Pressure range 1 0 … +P barMaximum Pressure P max. barDeviation of characteristic ED 520/x1, 4, 7 and 8, xA ± % FS ≤ 0,25 typ./0,4 max.(see diagram D0.320)curve (Tamb = 25°C) ED 520/x2 and 5, xB ± % FS ≤ 0,15 typ./0,2 max.(see diagram D0.320)Hysteresis and reproducibility ± % FS ≤ 0,2 (p < 0,4 bar) / 0,1 (p ≥ 0,4 bar)TC zero point ± % FS/10 K ≤TC sensitivity ± % FS/10 K ≤ 0,2Operating temp. (medium) comp./not. comp. °C according selection chartHousing temperature °C –20 … 80Storage temperature °C –40 … 80Supply voltage UB IA = 0 … 20 mA V DC –16 … 30
IA = 4 … 20 mA V DC –10 … 30UA = 0 … 5 V DC V DC –09 …30UA = 0 … 10 V DC V DC –14 … 30
Reverse polarity protection for supply voltage UB yesShort circuit proof output yesOvervoltage protection yesLoad (RL + RLine) IA = 0 … 20 mA Ohm ≤ 500
IA = 4 … 20 mA Ohm ≤ 1000 (see diagram D0.320)UA = 0 … 5 V DC kOhm ≥ 5UA = 0 … 10 V DC kOhm ≥ 10
Zero point adjusting range ± % FS 2Insulation resistance at 750 V DC MOhm ≥ 1,2Type of protection (DIN 40 050, IEC 144) according selection chartEMC emission (EN 50 081-1 und -2) fulfilledEMC immunity (EN 50 082-2) fulfilled
IEC 1000-4-2 / EN 61000-4-2 level 3 (8 kV) fulfilledIEC 1000-4-3 / ENV 50140 level 3 (10 V/m) fulfilledIEC 1000-4-4 / EN 61000-4-4 level 4 (4 kV) fulfilledIEC 1000-4-6 / ENV 50141 level (10 kV) fulfilled
Vibration test DIN IEC 68 fulfilledWeight kg 0,50
0,14
0,16…0,254
0,4…0,66
1…1,610
2…415
5…1030
16…2575
40…60100
100…160250
200…400600
0,20,5 0,35
with cone
plug DIN
plug Bendix
with cone
cable
plug
without cone
male connectorscrew holewasher
S._25-30_Kat.Elekt.E 17.01.2001 14:17 Uhr Seite 30
Ordering example: ED 522 / 3 1 1 . 2 1 1 / A15
System design EDX 522EEx ia II C (ATEX)3) EDX 522
Pressure type Gauge pressure 3Absolute pressure 4
Static error 0,4% FS (Tmed = 25˚C), comp. temp. -00 … 50°C 1band (Tmed = 25˚C) 0,2% FS (Tmed = 25˚C), comp. temp. -10 … 50°C 2
0,4% FS (Tmed = 25˚C), comp. temp. -10 … 80°C 40,2% FS (Tmed = 25˚C), comp. temp. -10 … 80°C 50,4% FS (Tmed = 75˚C), comp. temp. -50 …100°C 70,4% FS (Tmed = 100˚C), comp. temp. -75 …125°C 80,4% at specified adjusted temp., Tmax = 150˚C 1) A0,2% at specified adjusted temp., Tmax = 150˚C 1) B
Electrical connect. Cable 2 m IP 65 1Plug Fischer2) IP 67 2Plug DIN 41 524 (Binder) IP 65 3Plug DIN 43 650 IP 65 4
Output signal IA = 0 … 20 mA 1IA = 4 … 20 mA 2UA = 0 … 10 V DC 4UA = 0 … 5 V DC 5
Pressure connect. Clamp ISO 2852, nominal size 22 mm, < 1 bar with TC zero p. corr. 1Clamp ISO 2852, nominal size 38 mm (11⁄2’’) 3Clamp ISO 2852, nominal size 51 mm (2’’) 5Clamp ISO 2852, nominal size 63,5 mm (21⁄2’’) 6
Diaphragm Stainless steel 1.4404/316 L 1Stainless steel, gold plated 9
Pressure range also other pressure ranges and versions in Pa, psi, H2O etc. available
D6.162 E / 1.01Design and specifications subject to change without notice
Selection Chart
1) For temperature adjustments (medium) other than 25°C, the temperature has to be indicated by the order code /9007/XXXX. Ordering example: adjustment at 125°C, order code /9007/0125. The compensated temperature range is ±25°C of the adjusted temperature. If the temperature is above 125°C the range will always be 100°C to 150°C.
2) Cable socket included.3) Version 4 … 20 mA only.
Special Designs see D6.901 E / Accessories see D6.911 E
Electrical Connection (Pin assignments and cable colours see D0.320 E)
IA = 4 … 20 mA IA = 0 … 20 mA, UA = 0 … 5 V, UA = 0 … 10 V
Application Measurement of gauge and absolute pressurefor gases and liquids
Construction Stainless steel 1.4435Flush diaphragmClamp liner with gasket for the food industryISO 2852Zero point and span adjustment
Pressure range 100 mbar … 16 bar
Output signal 0 … 20 mA, 4 … 20 mA,0 … 5 V DC, 0 … 10 V DC
Static error band ≤ 0,25% FS typ., ≤ 0,15% FS typ.
Electrical connection Cable or plug
Pressure connection Clamp connection for quick mounting
Type of protection IP 65, IP 67
EMC Protected for industrial environments, conformingto EN 50081-2, EN-50081-1 and EN 50082-2
Accessory Test certificate
Pressure Transmitter with Flush Diaphragm and Clamp Connection ED 522
Order Pressurecode range
mbar126 0 … 100136 0 … 160A56 0 … 200
146 0 … 250156 0 … 400A66 0 … 500166 0 … 600
bar025 0 … 1035 0 … 1,6A15 0 … 2
045 0 … 2,5055 0 … 4A25 0 … 5065 0 … 6075 0 … 10085 0 … 16
Order Pressurecode range
mbarD06 -100 … -100D26 -100 … -200D56 -100 … -500
H66 -100 … -100H76 -200 … -200H86 -500 … -500
barD85 -0 … -1H05 -1 … -1525 -1 … -3
535 -1 … -5545 -1 … -9
74-00
S._31-36_Kat.Elekt.E 18.01.2001 15:38 Uhr Seite 31
D6.162 E / 1.01Design and specifications subject to change without notice
Medium pressureAdmissible medium pressure as a function of medium temperature
Pressure Transmitter with Flush Diaphragm and Clamp Connection ED 522Technical Data
Mountingexample
Accessories Order no.Clamp ring 20 D 12271.0000
11⁄2’’ D 12271.00012’’ D 12271.0002
21⁄2’’ D 12271.0003Gasket NBR/Nitril 20 D 12272.0100
11⁄2’’ D 12272.01012’’ D 12272.0102
21⁄2’’ D 12272.0103Clamp liner welding 1.4404 20 D 12273.0000
11⁄2’’ D 12273.00012’’ D 12273.0002
21⁄2’’ D 12273.0003
Pressure range 1 0 … +P barMaximum Pressure P max. barDeviation of characteristic ED 522/x1,x4, x7, x8, xA ± % FS ≤ 0,25 typ./0,4 max. (see diagram D0.320 D)curve (Tamb = 25°C) ED 522/x2,x5, xB ± % FS ≤ 0,15 typ./0,2 max. (see diagram D0.320 D)Hysteresis and reproducibility ± % FS ≤ 0,2 (p < 0,4 bar) / 0,1 (p ≥ 0,4 bar)TC zero point ± % FS/10 K ≤TC sensitivity ± % FS/10 K ≤ 0,2Operating temp. (medium) compensated °C according selection chartHousing temperature °C –20 … 80Storage temperature °C –40 … 80Supply voltage UB IA = 0 … 20 mA V DC –16 … 30
IA = 4 … 20 mA V DC –10 … 30UA = 0 … 5 V DC V DC –09 …30UA = 0 … 10 V DC V DC –14 … 30
Reverse polarity protection for supply voltage UB yesShort circuit proof output yesOvervoltage protection yesLoad (RL + RLine) IA = 0 … 20 mA Ohm ≤ 500
IA = 4 … 20 mA Ohm ≤ 1000 (see diagram D0.320)UA = 0 … 5 V DC kOhm ≥ 5UA = 0 … 10 V DC kOhm ≥ 10
Zero point adjusting range ± % FS 2Insulation resistance at 750 V DC MOhm ≥ 1,2Type of protection (DIN 40 050, IEC 144) according selection chartEMC emission (EN 50 081-1 and -2) fulfilledEMC immunity (EN 50 082-2) fulfilled
IEC 1000-4-2 / EN 61000-4-2 level 3 (8 kV) fulfilledIEC 1000-4-3 / ENV 50140 level 3 (10 V/m) fulfilledIEC 1000-4-4 / EN 61000-4-4 level 4 (4 kV) fulfilledIEC 1000-4-6 / ENV 50141 level (10 kV) fulfilled
Vibration test DIN IEC 68 fulfilledTest of cycles cycles ≥ 10 millionsWeight kg 0,30
0,5
0,1 … 0,254
0,4 … 0,66
0,1 … 1,610
2 … 415
5 … 1030
11 … 1630
0,35 0,2
Nominal size d (mm)22 mm 34
38 mm (11⁄2’’’) 50,551 mm 64
63,5 mm 77,5
Construction and FunctionPressure transmitter ED 522 consists of a pressure connection section withwelded stainless steel diaphragm and a stainless steel case for housingthe electronic circuit and the electrical connection. The piezoresistivepressure sensor is mounted right behind the diaphragm (except for thetypes ED 522/xAx and ED 522/xBx). The pressure being measured istransmitted by the external diaphragm and the oil filling to the measuringdiaphragm of the piezoresistive silicon sensor.
An amplifier converts the pressure sensor’s bridge signal to the desiredsignal level. The amplifier space is sealed to provide optimal shock andvibration resistance. The transmitter has a clamp connection for quickmounting.Access to the adjusting potentiometer is obtained by unscrewingthe closure ring. Both zero point and range can be adjusted with ascrewdriver.
Dimensions ED 522/xAx.xxxED 522/xBx.xxx
–0,5 bar
0 bar
p rel
–1 bar
prohibitedzone
Medium pressure
pabs
1 bar
0,5 bar
1 mbar0–50 0 50 100 200 300 Medium temperature °C
120
Clamp ring
Gasket
Clamp liner
S._31-36_Kat.Elekt.E 18.01.2001 15:38 Uhr Seite 32
D6.170 E / 1.01Design and specifications subject to change without notice
Ordering example: ED 530 / 3 1 4 . 2 1 1 / 025
System design ED 530EEx ib IIC (ATEX)1) EDX 530
Pressure type Gauge pressure 3Absolute pressure 4
Static error band 0,4% FS (Tmed = 25˚C), comp. temp. -00 … 50°C 1(Tamb = 25˚C) 0,2% FS (Tmed = 25˚C), comp. temp. -10 … 50°C 2
0,4% FS at specified adjusted temp.2) 70,2% FS at specified adjusted temp.2) 8
Electrical connect. Cable 2 m IP 653) 1Plug Bendix IP 653) 2Plug DIN 41 524 (Binder) IP 653) 3Plug DIN 43 650 IP 653) 4Cable 2 m with relative tube IP 673) 9
Output signal IA = 0 … 20 mA 1IA = 4 … 20 mA 2UA = 0 … 10 V DC 4UA = 0 … 5 V DC 5
Pressure connect. G1⁄2 with cone 1G1 with cone 2
Diaphragm Stainless steel 1.4404/316 L 1Hastelloy C-276 2Stainless steel, gold plated 9
Pressure range also other pressure ranges and versions in Pa, psi, H2O etc. available
Order Pressurecode range
mbar126 0 … 100136 0 … 160A56 0 … 200
146 0 … 250156 0 … 400A66 0 … 500166 0 … 600
bar025 0 … 1035 0 … 1,6A15 0 … 2045 0 … 2,5055 0 … 4A25 0 … 5
065 0 … 6075 0 … 10075 0 … 10
085 0 … 16A35 0 … 20095 0 … 25105 0 … 40A45 0 … 50
Con-nect.
G1G1G1
G1G1G1G1
G1G1G1G1G1G1
G1G1G1⁄2
G1⁄2G1⁄2G1⁄2G1⁄2G1⁄2
Con-nect.
G1⁄2G1⁄2G1⁄2
G1⁄2G1⁄2G1⁄2
G1G1G1G1G1G1
G1G1G1
G1G1
Order Pressurecode range
bar115 -100 … 60125 -100 … 100135 -100 … 160
A55 0… -200145 0… -250155 0… -400
mbarD06 -0… -100D26 0… -200D56 0… -500H66 -100… -100H76 -200… -200H86 -500… 500
barD85 -0 … -1H05 -1 … -1525 -1 … 3
535 -1 … -5545 -1 … -9
Pressure Transmitter for High Temperaturewith Flush Diaphragm ED 530
Selection Chart
1) Version 4 … 20 mA only (with IP 42)2) Temperature adjustments
If the adjustment of the media temperature deviates from 25°C, ther order code must be defined with /9007/XXXX.Ordering example: adjustment on 150°C, order code /9007/0150. The compensated temperature range is ±25°C of the adjusted temperature. If the adjusted temperature is above 125°C, the compensated temperature range will always be 100°C to 150°C.
3) Not available for EEx.
Special Designs see D6.901 E / Accessories see D6.911 E
Electrical Connection (Pin assignments and cable colours see D0.320 E)
IA = 4 … 20 mA IA = 0 … 20 mA, UA = 0 … 5 V, UA = 0 … 10 V
Application Measurement of absolute and relative pressure ofgases and liquids for temperatures up to 300°C
Construction Flush diaphragmSeal either flush (for food applications) or behindthread according to DIN 3852 form AExternal zero point and span adjustment
Pressure range 100 mbar … 400 bar
Output signal 0 … 20 mA, 4 … 20 mA,0 … 5 V DC, 0 … 10 V DC
Static error band ≤ 0,25% FS typ., ≤ 0,15% FS typ.
Medium temperature –40 … 300°C
Electrical connection Cable or plug
Pressure connection Male thread G1⁄2, G 1 with cone
Type of protection IP 65, IP 67
EMC Protected for industrial environments, conformingto EN 50081-2, EN-50081-1 and EN 50082-2
Accessory Test certificate
S._31-36_Kat.Elekt.E 18.01.2001 15:38 Uhr Seite 33
Pressure range 1 0 … +P barMaximal Pressure P max. barDeviation of characteristic ED 530/x1 ± % FS ≤ 0,25 typ./0,4 max.(see diagram D0.320)curve (Tamb = 25°C) ED 530/x2 ± % FS ≤ 0,15 typ./0,2 max.(see diagram D0.320)Hysteresis and reproducibility ± % FS ≤ 0,2 (p < 0,4 bar) / 0,1 (p ≥ 0,4 bar)TC zero point1) ± % FS/10 K ≤TC sensitivity1) ± % FS/10 K ≤ 0,2Operating temp. (medium) °C –40 … 300 (see diagram medium pressure)Housing temperature2) °C –20 … 80Storage temperature °C –40 … 80Supply voltage UB IA = 0 … 20 mA V DC –16 … 30
IA = 4 … 20 mA V DC –10 … 30 (see diagram)UA = 0 … 5 V DC V DC –09 …30UA = 0 … 10 V DC V DC –14 … 30
Reverse polarity protection for supply voltage UB yesShort circuit proof output yesOvervoltage protection yesLoad (RL + RLine) IA = 0 … 20 mA Ohm ≤ 500
IA = 4 … 20 mA Ohm ≤ 1000 (see diagram D0.320)UA = 0 … 5 V DC kOhm ≥ 5UA = 0 … 10 V DC kOhm ≥ 10
Zero point adjusting range ± % FS 2Insulation resistance at 750 V DC MOhm ≥ 1,2Type of protection (DIN 40 050, IEC 144) according selection chartEMC emission (EN 50 081-1 and -2) fulfilledEMC immunity (EN 50 082-2) fulfilled
IEC 1000-4-2 / EN 61000-4-2 level 3 (8 kV) fulfilledIEC 1000-4-3 / ENV 50140 level 3 (10 V/m) fulfilledIEC 1000-4-4 / EN 61000-4-4 level 4 (4 kV) fulfilledIEC 1000-4-6 / ENV 50141 level (10 kV) fulfilled
Weight kg 0,25
D6.170 E / 1.01Design and specifications subject to change without notice
Pressure Transmitter for High Temperaturewith Flush Diaphragm ED 530
Construction and Function
Medium pressureAdmissible medium pressure as a function of medium temp.
Dimension chart
Plug Bendix DINL2 12,5 10
1,83)
Technical Data
0,14
0,16…0,254
0,4…0,66
1…1,610
2…415
5…1030
16…2575
40…60100
100…160250
200…400600
1,03) 0,5) 0,35) 0,2/0,43) 0,23) 0,23) 0,23) 0,23)
Dimensions
D h1 h2 L1
G1⁄2’’ 22 85 96,5
G1’’ 27 89 91
1) Calibration temperature ± 25°C.2) The ambient air should not rise above 50°C; otherwise the temperature of the transmitter section may exceed the admissible limit.3) For pressure connection G1⁄2.
The pressure transmitter for high temperature duty consists of apressure connection with its heat-resistant welded inox pressure trans-mitting diaphragm and an inox transmitter section containing the elec-tronics and the electrical connection. The pressure sensor is located inthe transmitter section and is separated from the pressure connectionsection by a capillary tube.
Four inox rods link the pressure connection to the transmitters sectionin orders to avoid mechanical stress to the capillary tube. The pressuresensor’s signal is converted by an amplifier to a signal of 0 … 20 mA,4 … 20 mA, 0 … 5 V DC oder 0 … 10 V DC.The transmitters are equipped with external zero point and span adjust-ment.
p rel
0 bar
–0,5 bar
–1 bar
cable compressionfitting
plastic sheath ofgrey PVCcore cross-section: 0,34 mm2
tin-platedcopper cloth
prohibitedzone
Medium pressure
Medium temperature (°C)
plug
screw in-torque: 60 Nm(85 Nm for 1000 bar)
zero point adjustment
span adjustment
cable
S._31-36_Kat.Elekt.E 18.01.2001 15:42 Uhr Seite 34
D6.192 E / 1.01Design and specifications subject to change without notice
Ordering example: ED 552 / 3 1 1 . 1 1 1 / 126 / 9001 / 0100
System design EDX 552EEx ia II C (ATEX)1) EDX 552
Pressure type Gauge pressure 3Static error band 0,5% FS (Tmed = 20˚C), comp. temp. -5 … 30°C 1(Tamb = 20˚C) 0,3% FS (Tmed = 20˚C), comp. temp. -5 … 30°C 2
0,2% FS (Tmed = 20˚C), comp. temp. -5 … 30°C 3Electrical connect. Cable 2 m with relative tube 1Output signal IA = 0 … 20 mA 1
IA = 4 … 20 mA 2UA = 0 … 10 V DC 4UA = 0 … 5 V DC 5
Pressure No protection, flush 1connection Protection grating 2protecting pieces Stainless steel cap with G1⁄4’’ female thread and grating 3to be screwed
Protection grating ø 52 mm stainless steel, hemispherical 4Stainless steel cap with grating 7
Diaphragm Stainless steel 1.4404/316 L 1Hastelloy C-276 2
Pressure range also other pressure ranges and versions in Pa, psi, H2O etc. availableCable length
Order Pressurecode range
mbar126 0 … 100136 0 … 160A56 0 … 200
146 0 … 250156 0 … 400A66 0 … 500166 0 … 600
bar025 0 … 1035 0 … 1,6A15 0 … 2
045 0 … 2,5055 0 … 4A25 0 … 5065 0 … 6
075 0 … 10085 0 … 16A35 0 … 20
095 0 … 25105 0 … 40A45 0 … 50
Pressure Transmitter for HydrostaticDepth Measurement ED 552
Selection Chart
1) Version 4 … 20 mA only
Special Designs see D6.901 E / Accessories see D6.911 E
Application Water level measurement in fountains,bore holes, vessels or still waters
Construction Stainless steel 1.4435
Pressure range 100 mbar … 50 bar
Output signal 0 … 20 mA, 4 … 20 mA0 … 5 V DC, 0 … 10 V DC
Static error band 0,4% FS typ., 0,25% FS typ., 0,15% FS typ.
Electrical connection Cable with reference air pipe
Pressure sensor Exchangeable protection cap to avoid damages
Type of protection IP 68
EMC Protected for industrial environments, conforming to EN 50081-2, EN-50081-1and EN 50082-2
Accessory Test certificate
(please see alsochart on the reverse)
Ord
erin
g co
de
for
cab
le le
ngth
Cab
le le
ngth
in d
me.
g. L
= 1
0 m
Electrical Connection (Pin assignments and cable colours see D0.320 E)
IA = 4 … 20 mA IA = 0 … 20 mA, UA = 0 … 5 V, UA = 0 … 10 V
S._37-38_Kat.Elekt.E 18.01.2001 15:44 Uhr Seite 37
D6.192 E / 1.01Design and specifications subject to change without notice
Pressure range 1 0…+P bar
Maximum Pressure P max. bar
Deviation of characteristic ED 552/31x.xxx ± % FS ≤ 0,4 typ./0,5 max. (see diagram D0.320 D)curve (Tamb = 25°C) ED 552/32x.xxx ± % FS ≤ 0,25 typ./0,3 max. (see diagram D0.320 D)
ED 552/33x.xxx ± % FS ≤ 0,15 typ./0,2 max. (see diagram D0.320 D)
Hysteresis and reproducibility ± % FS ≤ 0,2 (p < 0,4 bar) / 0,1 (p ≥ 0,4 bar)
TC zero point ± % FS/10 K ≤TC sensitivity ± % FS/10 K ≤ 0,25
Operating temp. (medium) comp./not comp. °C –5 … 30 / –5 … 60
Housing temperature °C –20 … 60
Storage temperature °C –40 … 80
Supply voltage UB IA = 0…20 mA V DC –16 … 30
IA = 4…20 mA V DC –10 … 30
UA = 0…5 V DC V DC –09 …30
UA = 0…10 V DC V DC –14 … 30
Reverse polarity protection for supply voltage UB yes
Short circuit proof output yes
Overvoltage protection yes
Load (RL + RLine) IA = 0…20 mA Ohm ≤ 500
IA = 4…20 mA Ohm ≤ 1000
UA = 0…5 V DC kOhm ≥ 5
UA = 0…10 V DC kOhm ≥ 10
Insulation resistance at 750 V DC MOhm ≥ 1,2
Type of protection (DIN 40 050, IEC 144) IP 68
EMC emission (EN 50 081-1 and -2) fulfilled
EMC immunity (EN 50 082-2) fulfilled
IEC 1000-4-2 / EN 61000-4-2 level 3 (8 kV) fulfilled
IEC 1000-4-3 / ENV 50140 level 3 (10 V/m) fulfilled
IEC 1000-4-4 / EN 61000-4-4 level 4 (4 kV) fulfilled
IEC 1000-4-6 / ENV 50141 level (10 kV) fulfilled
Weight (without cable) kg 0,16
0,3
Pressure Transmitter for HydrostaticDepth Measurement ED 552Technical Data
Construction and FunctionThe transmitter consists of a pressure part with a welded stainless steeldiaphragm and a stainless steel housing with built-in electronics. Theconnecting cable is mounted to case. Several parts to protect thediaphragm (caps, gratings) may be screwed. The pressure sensitivesilicon sensor is located behind the diaphragm. Atmospheric pressureis led to the interior of the sensor via the integrated air pipe of the cable.The water level is exerted on the oil – and thus on the sensor – as a
hydrostatic pressure over the diaphragm. A a result of the piezoresisti-ve effect, the resistors change their values linearly with the water level.The resistance bridge therefore generates a signal proportionally to thedifference between the hydrostatic and the atmospheric pressure. Theintegrated amplifier transforms the signal into a current of 0 ... 20 mAresp 4 ... 20 mA. Changes in atmospheric pressure don’t have anyinfluence to the measurement.
0,1…0,25
4
0,4…0,6
6
0,1…1,6
10
2…4
15
5…10
30
16…25
75
50
75
0,25 0,2 0,2 0,2 0,2
Ordering code for the individual protection capsED 552/XXX.X1X Pressure transmitter (Pos.1) no capED 552/XXX.X2X Pressure transmitter (Pos.1) with protection grating D 12583.0000 and cap (Pos. 2) D 12582.001ED 552/XXX.X3X Pressure transmitter (Pos.1) with protection grating D 12583.0000 and cap with female thread (Pos. 3) D 12582.0003ED 552/XXX.X4X Pressure transmitter (Pos.1) with hemispherical protection grating (Pos. 4) D 12582.0000ED 552/XXX.X7X Pressure transmitter (Pos.1) with protection grating and stainless steel cap (Pos. 7) D 12582.0002
Dimensions
4 3 7 2 1
Alu strip screening
Tinned copper braid
Air pipe
Plastic sheath of black polyethyleneCore cross-section 0,34 m2
Air pipe Ø = 1,3 mm
S._37-38_Kat.Elekt.E 18.01.2001 15:44 Uhr Seite 38
made to measure
Data Sheet A11 D6.180
Pressure Transmitter ED 701
Hygienic and industrial process connections
Zero setting function
Accuracy < 0,1% FS
Quick response time < 25 ms
High long-term stability
Excellent repeatability
Active compensation for temperature drifts
4 ... 20 mA and Voltage outputs
Complete range of electrical connections
ATEX II 1 G, EEx ia IIC T4 / T6 (Pending)
CIP/SIP
Description
The ED 701 is a pressure transmitter available in 4 ... 20 mA current loop or in voltage output signal versions. This transmitter offers a very high ac cu ra cy over a wide tem per a ture range, an excellent repeatability and very long term sta bil i ty.
The piezo-resistive sil i con sensor is anodic bond ed on a very stable glass base, which is attached to a stainless steel con struc tion. This assembly guar an ties an excellent ther mal isolation.The sensor is isolated from the process by a stainless steel diaphragm (1.4404 / 316L) and a fi lling liquid.
The electronics are located within the hermetically sealed trans- mit ter housing which give the ED 701 an excellent re sis tance to humidity, shock and vibration. Protection class, from IP 65 to IP 67 only de pends on the choice of the electrical connection.
The electronics are a state-of-the-art signal processing unit fi tted with a fast micro-controller allowing the com pen sa tion of drift effects due to temperature on the sensor sig nal, over a wide temperature range with a fast response time.
The ED 701 is available with a great variety of pres sure and electrical connections to meet all requirements. The elec tri cal connection can be replaced easily and gives ac cess to the Auto-zero adjustment.
The ED 701 is a very fl exible transmitter suitable for all types of applications and more specifi cally for food and beverage, phar-maceutical, and biotech ap pli ca tions.
Data Sheet A 11 D6.180
Ordering Details
Ordering code digit 1 2 3 4 5 6 7 8 9 10 11 12
Raccordement au processusMale thread G1⁄2” EN 837 1 Male thread G1⁄4” EN 837 2 Male thread M20x1,5 EN 837 3 Male thread G1⁄2” DIN 3852 with O’ring3) 4 Male thread G1⁄8” EN 837 5 Female thread G1⁄2” DIN 3852 6 Female thread G1⁄4” DIN 3852 7 Male thread 1⁄2”- 14NPT, ASP N152 A Female thread 1⁄4”-18NPT, ASP N152 B Male thread 7/16- 20UNF EMale thread G1” fl ush diaphragm cone3) J Male thread G1” fl ush diaphragm O’ring3) K Male thread G1⁄2” fl ush dia. DIN 3852 (Combi Connect)3, 4) L Clamp DN 38, ISO 28521) N Clamp DN 51, ISO 28521) P Clamp DN 64, ISO 28521) Q
Output signal4 ... 20 mA 2 0 ... 10 V DC 4 0 ... 5 V DC 5 Approvals
None 0ATEX (pending) 1CSA (pending) 2
Electrical connection2 meter shielded cable 3 conductors 1 Fischer Plug (IP 67)2) 2DIN 41524 Binder Plug 3 DIN 43650 Plug 4 Bendix 6 pole Plug 5 M12, 4 pole Industrial Plug 6 1⁄2” NPT, cable length 1 m (IP 67) 7 2 meter shielded cable 3 conductors, IP 67 9 Field Housing IP 67 (cable diameter 5 to 12 mm) A
Accuracy 0,4% FS, Compensated Temperature –10 ... 80°C 10,2% FS, Compensated Temperature –10 ... 80°C 20,1% FS, Compensated Temperature –10 ... 80°C 3
1) Pressure range up to 20 bar. Maximum pressure depends on clamp fork.Operating temperature must be considered.
2) Cable socket included.3) See code 10 for O’ring selection.4) Pressure range from 1 bar with Combi Connect.
Ordering details (continued)
Ordering code digit 1 2 3 4 5 6 7 8 9 10 11 12 Pressure units
Gauge pressure 3Absolute pressure 4Negative gauge pressure (Pending) 5
Pressure range1) 100 mbar up to 40 bar: gauge pressure See code500 mbar up to 40 bar: absolute pressure below
1) Avec Combi Connect, à partir de 1 bar
Wetted parts All Stainless Steel 1O’ring NBR* 5O’ring Viton* 6O’ring EPDM* 7
* See code 1 for pressure connection
Oil fi lling
Standard, Silicon 0FDA approved white oil 1Silicon free / oxygen service (Pending) 2
Pressure range details
Code Range Code Range Code Range mbar bar bar
126 0...100 025 0...1 095 0...25136 0...160 035 0...1,6 105 0...40A56 0...200 A15 0...2 146 0...250 045 0...2,5 156 0...400 055 0...4 A66 0...500 A25 0...5 166 0...600 065 0...6
Data Sheet A11 D6.180
Technical data
Measurement characteristics
Pressure range Gauge pressure 0...100 mbar, 0...40 bar Abs. pressure 0...500 mbar, 0...40 barPressure ranges available within the defi ned ordering code.
AdjustmentAuto-Zero function by press-button located behind the electrical plug.Please remove plug to get access.
Overpressure At least 3 times nominal value
Accuracy According to ordering code 4
Hyteresis and repeatability +/- 0.05% FS
Long term stability +/- 0.2 % FS/year
Temperature infl uence (compensated range –10 ... 80°C)
Accuracy code 5 = 1 (+/-0,4% FS)TC zero = +/-0,3% FS/10KTC Span = +/-0,2% FS/10KAccuracy code 5 = 2 (+/-0,2% FS)TC zero = +/-0,2% FS/10KTC Span =+/- 0,15% FS/10KAccuracy code 5 = 3 (+/-0,1 %FS)TC zero = +/-0,05% FS/10KTC Span = +/-0,05% FS/10K
Response time 10 ... 90%, 25 ms
Electrical specifi cation
Supply voltage 10 ... 30 V DC
Insolation Resistance >1 GOhm, 500 V DC
Load RL < 50 x UB - 450
Infl uence of the Power supplyProtected against reverse signal po lar i ty.
Temperature characteristics
Operating Temperature-30 ...125 °C not compensated for wetted parts all in stainless steel-10°C ... 80 °C Compensated-20°C ... 125°C with Viton O’ring-30°C ... 120°C with EPDM O’ring-20°C ... 80°C with NBR O’ring
Compensated Temperature -10 ... 80°C
Sterilisation Temperature 140°C, 30 minutes
Storage Temperature-55° ... 150°C For version fi tted with O’ring seals, refer to operating Temp.
Temperature characteristics (FDA white oil)
Minimal temperature–10°C
Materials specifi cation
Wetted partStainless Steel W.1.4435 (fi tting body) and W.1.4404 (AISI 316L, diaphragm)
Parts not in contact with mediumStainless Steel W.1.4301 (housing), W.1.4305 (AISI 304 connec-tor base) and elec tri cal con nec tor material.
Certifi cate EN10204 3.1B available on request
EMC
Infl uence of EMC Less than 0,15% FS
Data Sheet A 11 D6.180
Technical data
Environmental specifi cation
Humidity According to EN 60068-2-38
Vibrations According to EN 60068-2-6
Shocks According to EN 60068-2-6
SterilisationComplete device, not powered, only fl ush diaphragm versions (without O’ring seal) and Fischer electrical plug.Process duration 60 minutes, not powered, sterilisation tempera-ture max. 140°C, pressure 3500 mbar.
Protection class
Rating IP 65 and IP 67, Depending on electrical plug.
Mounting
Position at calibration time: Vertical
Switch ON time
5 sec.
Test Certifi cate
Delivered with the transmitter. Test certifi cate, 6 points risingat ambient temperature (Tamb = 25°C).
Physical characteristics
Weight Between 223 and 885 g depending of the version.
DimensionsSee drawings.
Zero setting function
The Zero setting function is available directly on the device by removing the electrical plug. The Zero is ac ti vat ed pressing the push button located on the top of the electronic unit. Pressing
the Zero button will cause the applied pressure to be considered as zero. This function allows ini tial iza tion of the zero point e.g. in level measurement.
Data Sheet A11 D6.180
Drawing
DIN 43650 plug Bendix 6 pole plug Cable 3 conductors DIN 41524Binder plug
34 34 34 34
17 20
10.4 17
key 27key 27
key 41
d3
d2
d1
d1
d1
d2
l 1
l 1l 2l 1
l 2
l 323 25
12
70°
Mounting example
Thread d1 d2 d3 l1 l2 l3G1⁄2 6 17,5 20 5 3M20x1.5 6 17,5 20 5 3G1⁄4 6 9,5 11 3 2G1⁄8 6 8 8 2,5 2
Thread d1 l1 G1⁄2 141⁄2-14NPT 20
Thread d1 d2 l1 l2 G1 20 9 18
Seal
Seal
Screw hole
Screw hole
Screw hole
Pressure port
Pressure port
Pressure port
Data Sheet A 11 D6.180
Drawing
Fischer plug NPT 3 conductors M12 industrial plug Field housing
34 34 34 55
17 13
10.4
50
34
61.5
Thread d1 d2 l1 l2G1 30 12,5 20,5
Thread d1 d2 l1 l27/16-20UNF 9,2 4,5 9
Thread d1 d2 l1 l2G1⁄2 6 20 5G1⁄4 28 14 17,51⁄2-18NPT 28 10,2 12,5
Clamp d1 l1 50.5 1564 1577.5 15
Mounting example
Seal
Seal
Seal
key 41
d2
d1
l 1
l 212
key 27
d2
d1
l 1l 2
23
l 3
45°
key 27
d2
d1
l 1 l 223
d1
l 1
Screw hole
Screw hole
Screw hole
Pressure portPressure port
Pressure port
Pressure port
Clamp
Data Sheet A11 D6.180
E/2
003-
01-0
1 Th
is d
ata
shee
t m
ay o
nly
be
rep
rod
uced
in fu
ll.
Connecting diagram
Electrical connection
For Voltage signal Output 0 … max. 10 V For 4 ... 20 mA current loop version
Pin assignment
Contact DIN 43650 plug Bendix 6 poles plug Cable 3 conductors DIN 41524 Binder plug
4...20 mA Voltage 4...20 mA Voltage 4...20 mA Voltage 4...20 mA Voltagea 1 1 B B Blue Blue 3 3b 2 2 E E Brown Brown 1 1c - 3 - D - Black - 4d GND GND Case Case Case Case
Viewsoldering side,cable socket 3
2 1
AF
ED
C
B
1
23
4
5
Pin assignment
Contact Fischer plug NPT 3 conductors M12 industrial plug Field housing
4...20 mA 0...5/10VDC 4...20 mA 0...5/10VDC 4...20 mA 0...5/10VDC 4...20 mA 0...5/10VDCa 1 1 Red Red 3 3 1 1b 2 2 Black Black 1 1 2 2c - 3 - Green - 4 - 3d Case Case Case Case 4 4
Viewsoldering side,cable socket
1 2
341
34
2 1 2 3 4
red blackgreen
blue
blackbrown
–
+
a
b
c
d
IA
UA RL
UB +
–
UB
RLIA
a
b
d
Data Sheet A 11 D6.180
1
Description
Turn Down up to 1:16
Accuracy better than 0.1%
High long term stability
Diff. pressure range 3.75 mbar...20 bar
Line pressure up to 140 bar
HART® communication
Zero adjustment
Damping
Robust and modular design
Square root output (FKK)
Linearisation table (FKK)
Analogue or digital display (Option)
The EDD575 differential pressure transmitter accuratelymeasures differential pressureand transmits a4...20mA/ HART® signal based on linear output orsquare root (FKK).
0.1% accuracy for all configured spans is the standardfeature covering differential ranges from 0.0375 bar to20 bar.
The micro-capacitance silicon sensor element assuresthis accuracy for all elevated or suppressed measuringranges without additional adjustment. Silicon has greatmechanical properties, such as no hysteresis featuringan excellent repeatability.
The compensation data is stored in the sensor device,making it possible to replace the electronics unit, theHART® communication module and the local indicatorswithout re-calibrating the complete assembly.
The HART® communication module can be configuredwith a standard HART® communicator.
Analogue and digital indicators can be mounteddisplaying individual read-outs.
The EDD575 is suitable for a wide range of processapplications in differential pressure, level and flowmeasurements.
EDD575 Differential Pressure TransmitterEDD575-1
Technical Data
Static pressure, span and range limits
Static RangeType pressure FHK FKK FHK/FKK limit
(bar) Min. Min. Max. (mbar)FxKx12 ´-1...32 6 3.75 60 ±60FxKx33 ´-1...140 32 20 320 ±320FxKx35 ´-1...140 130 81.25 1300 ±1300FxKx36 ´-1...140 500 312.5 5000 ±5000
FxKx37 ´-1...140 2000 1250 20000 ±20000
Span limits (mbar)
Process connection1/4-18 NPT, meets DIN 19213.
Static pressure - lower limit
Output linearization(Model FKK only)14 points linearization table configurable from HHC.
Accuracy for lineary output(including linearity, hysteresis and repeatability)
Span > 1:10 of URL: ±0.1% of span
Span < 1:10 of URL (model FKK only):
± (0.05 + 0.05(0.1 x URL/Span))% of span
Accuracy for square root output(Model FKK only)
Output Span > 1:2.5 of URL
50..100% ±0.1%
20...50% ±0.25%
10..20% ±0.5%
Output Span < 1:2.5 of URL
50..100% ±(0.05 + 0.05 x 0.1 x URL/span)%
20...50% ±2.5 x (0.05 + (0.05 x 0.1 x URL/span))%
10..20% ±5 x (0.05 + (0.05 x 0.1 x URL/span))%
Communication(Model FKK only)
Notes1 A standard HHC (e.g. model 275) must be higher thanversion 5.0 or a FXW####1-#2 must be used,e.g. FXW 28AA1-A2
2 HHC must be higher than version 5.3
Items Display Set Display SetTag no. x x x x
Model no. x x
Serial no. Yes x Engineering unit x x x x
Range limit x x
Measuring range x x x xDamping x x x x
Output mode x x x x
Burnout direction x x xAdjustment x x x x
Output adjust x x x xData x x
Self diagnoses x x
Printer x External switch lock x x x x
Display 1 x x
Linearise 2 x xRe-range 2 x x
HART® Protocol FXW Protocol
Operatingpressure
mbar (abs)
1010
200
40
27
0
Operating area
Silicone Oil:
-40 60 100 °C
Process temperature
Fluorinated oil:660 mbar abs at temperatures below 80°C
Static pressure - overrange limitDiff. pressure < 60 mbar: 32 barDiff. pressure > 60 mbar: 140 bar
MediaLiquid, gas or vapour
Unit conversion1MPa=103kPa=10bar=10.19716kgf/cm2=145.0377PSI
1kPa=10mbar=101.9716mmH2O=4.01463inH
2O
OutputModel FHK: 4...20mA, 2-wire, linear
Model FKK: 4...20mA, 2-wire with HART®
linear or square root
Normal / reverse outputModel FHK: Selectable with a jumper pin located on theelectronics unit.
Model FKK: Selectable from the Hand Held Communicator
Technical Data
Zero and span adjustmentModel FHK and FKK:Zero and span are adjustable with an external adjustablescrew. The function is determined with the MODE switch.MODE FunctionZero Adjust zeroSpan Adjust spanInhibit Disable adjustment screw
Model FKK only:Span Adjustable with the Hand Held Communicator
Zero Adjustable with the Hand Held Communicator
Zero elevation / suppression–100...100% of URL
Low flow cut-offUser configurable for any point between 7...20% ofoutput (Model FKK only)
Burnout directionIf the self-diagnostic function detects a transmitterfailure, the analog signal will be driven to either "OutputHold", "Output Overscale" or "Output Underscale" modes.
Model FHK: Unless otherwise specified in the order, thetransmitter will be shipped in "Output Hold" mode.
Model FKK: Selected from HHC
"Output Hold": Output signal is hold as the value justbefore failure happens.
"Output Overscale": Approx. 21.6 mA(Adjustable within 20.8...21.6 mA with the HHC)
"Output Underscale": Approx. 3.8 mA(Adjustable within 3.2...3.8 mA with the HHC)
Underscale Nominal output Overscale
Lineary output
3.2 3.8 4.0 20 20.8 21.6 mA
Loop-check outputModel FHK: The transmitter can output a constant signalof 4mA, 12mA or 20mA if the MODE switch is set to „loopcheck“ mode.
Model FKK: Transmitter can be configured to provide aconstant output of 3.8...21.6mA by HHC.
IndicationAnalog indicator or 4 ½ digit LCD meter
Power supplySupply range 10.5...45V DC
Arrester option 10.5V...32V DC
Load limitationsNote: Communication with a handheld communicatorrequires a min. circuit resistance of 250 Ohms.
Operational conditionsAmbient temperatureStandard model –40...85°C
With LCD indicator –20...80°C
With Arrester option –40...60°C
With Fluorinated oil filling –10...60°C
Process temperatureSilicone oil filling –40...100°C
Fluorinated oil filling –20...80°C
Storage temperature –40...90°C
Humidity 100% RH
Mounting position effectPer 10° tilt in any plane
Span: No effect
Zero shift: < 1.2mbar for silicone oil
Zero shift: < 2.4mbar for flourinated oil
This error can be corrected by adjusting Zero.
Temperature effect - Lineary outputPer 28°C change at the process connectionin the range –40...85°C:
Ordering code Effect(6th digit)
„2“ Zero: ±(0.25 x URL/span)%Total: (Zero effect + 0.25)%
„3, 5, 6, 7“ Zero: ±(0.1 x URL/span)%Total: (Zero effect + 0.075)%
Temperature effect - Square root output(Model FKK only)
Per 28°C change at the process connectionin the range –40...85°C:
Ordering code Shift at 20% output point(6th digit)
„2“ ±(0.625 x URL/span) %„3, 5, 6, 7“ ±(0.25 x URL/span) %
Ohm
2000
15331500
1000
600500250
10.5 16.1 24 45 Volt
Operating area
Technical Data
Static pressure effectOrdering code Effect(5th digit)
„1“ (per 32 bar) Zero: ±0.4% of URLSpan: ±0.4% of span
„3“ (per 100 bar) Zero: ±0.2% of URLSpan: -0.5...0% of span
Overrange effectOrdering code Effect(5th digit)
„1“ (per 32 bar) Zero: ±0.4% of URL
„3“ (per 140 bar) Zero: ±0.4% of URL
Supply voltage effectLess than 0.05% of span per 10V.
RFI effectLess than 0.2% of URL for the frequencies of 20 to1000MHz and field strength 30 V/m when electronicscovers on.
(Classification: 2-abc: 0.2% span per SAMA PMC 33.1)
Stability0.2% of upper range limit (URL) for 24 months
(In case of 6th digit ordering code "3", "5", "6", "7")
DampingModel FHK:Time constant fixed: 0; 0.3; 1.2; 4.8; or 19.2 sec.
Model FKK:Time constant adjustable in the range 0...38.4 sec.
Step response(without electrical damping)
Ordering code Time Constant Dead Time(6th digit)
„2“ 0.85 sec. 0.3 sec.
„3“ 0.45 sec. 0.3 sec.
„5, 6, 7“ 0.2 sec. 0.3 sec.
EMC dataImmunity EN 50082-2
Emission EN 50081-1
Approval EEx ia IIC T4/T5Temperature class T1...T4: -40 < Tamb < 85°C
T1...T5: -40 < Tamb
< 70°C
Barrier data U < 30 VDC
; I < 0.1 A; P < 0.75 W
Zones Media: 0; Housing: 0
Wetted parts materialProcess cover, wetted sensor body and vent/drainAISI 316 (W.1.4436 or W.1.4401)
DiaphragmAISI 316L (W.1.4404 or W.1.4435)
Sensor gasketViton O-rings or PTFE square section gasket.
Non-wetted parts materialElectronics housing
Low copper die cast aluminum alloy (standard), finishedwith epoxy/polyurethane double coating.
Bolts and nuts
Cr-Mo alloy (standard):AISI 316 (W.1.4436) or AISI 630 (W.1.4542)
Mounting bracket AISI 304 (W.1.4301)
Filling fluidSilicone oil (standard) or fluorinated oil (Daifloil)
Other mechanical dataProtection class IP67 and NEMA 4X
Mounting On 50mm (2") pipe usingmounting bracket,direct wall mounting ordirect process mounting.
Weight 3.4kg without options.
+ 0.5kg for mounting bracket
+ 0.8kg for indicator (option)
Electrical connectionsG1/2, 1/2-14 NPT, Pg13.5 or M20 x 1.5 conduit
Other electrical dataDielectric strength 500 V AC ,50/60 Hz, 1 min.
between circuit and earth
Insolation resistance > 100 Mohm at 500 V DC
Power-on time 4 sec.
Internal resistance for external field indicator: < 12 Ohm
Optional featuresIndicatorA plug-in turnable analog indicator (1.5% accuracy) canbe located in the electronics compartment or in theterminal box of the housing.
An optional 4½ digits LCD meter is also available.
ArresterA built-in arrester protects the electronics from lightningsurges.
Lightning surge immunity: 4KV (1.2 x 50µs)
Oxygen measurementSpecial cleaning procedures are followed throughout theprocess to maintain all process-wetted parts oil-free.
The filling fluid is fluorinated oil.
DegreasingProcess-wetted parts are cleaned, but the fill fluid isstandard silicone oil.
Not for use for oxygen or chlorine measurement.
NACE specificationMetallic materials for all pressure boundary parts complywith NACE MR-01-75. AISI316 stainless steel bolts andnuts, ASTM B7M or L7M bolts and 2HM nuts (Class II).
DiaphragmGold coating upon request
Technical Data
Connection diagram
76
20
GND + - CK+ CK-
4...20 mA
and HART®
Analogue
display
AccessoriesOval flangesConverts process connection to 1/2-14 NPTMaterial AISI 316 (W.1.4436 or W.1.4401)
Three-valve manifoldAvailable in carbon steel or in AISI 316 (W.1.4436 orW.1.4401) stainless steel and in pressure rating 140 bar.
Hand-held communicatorModel FXW or model 275
Communication module(standard for model FKK)
When using this module for model FHK, remote settingfunction becomes available.
Note :When the communication module is connected, theoperation mode of external zero/span adjustable screw ischanged to zero adjustment only.
Test certificateTest certificate based on 5 measuring points up and downis included.
Optional stainless steel tagA stainless steel tag with customer data is wired to thetransmitter.
Ordering Details
FxK xxxx xxxx xxxxHK
TVWX
12V33V35V36V37V
1A1B1C1D1J1E1F1G1H1K1L1P1M1Q1S1N
AK
ACDF
YB
YGAN
AC
ACDEF
TypeOutput 4...20 mA (linear output)Output 4...20 mA + HART® communication (configurable linear or square root output)
Process connection Oval flange screw Electrical connection1/4 - 18 NPT 7/16 - 20 UNF 1/2 - 14 NPT1/4 - 18 NPT M10 or M12 3 PG13.51/4 - 18 NPT M10 or M12 3 M20 x 1.51/4 - 18 NPT 7/16 - 20 UNF PG13.5
Static pressure Span (max) Diaphragm Cover and body-1...32 bar -60...60 mbar 4 AISI316L AISI316-1...140 bar -320...320 mbar 4 AISI316L AISI316-1...140 bar -1.3...1.3 bar 4 AISI316L AISI316-1...140 bar -5...5 bar 4 AISI316L AISI316-1...140 bar -20...20 bar 4 AISI316L AISI316
Indicator ArresterNone noneAnalogue, 0...100% linear scale noneAnalogue, 0...100% square root scale noneAnalogue, customer scale noneAnalogue, double scale, please specify noneNone yesAnalogue, 0...100% linear scale yesAnalogue, 0...100% square root scale yesAnalogue, customer scale yesAnalogue, double scale, please specify yesDigital, 0...100% noneDigital, customer scale (FKK only) noneDigital, 0...100%, square root scale noneDigital, 0...100% yesDigital, customer scale (FKK only) yesDigital, 0...100%, square root scale yes
Ex ApprovalNone (standard)EEx ia IIC T4/T5
Side vent/drain Mounting bracketNone NoneNone Yes, stainless steelYes NoneYes Yes, stainless steel
Tag plateNoneYes
Treatment Filling fluidNone (standard) Silicone oilDegreasing Silicone oilOxygene application Fluorinated oilNACE, Note 5 Silicone oil
Process cover gasket in stainless steel flangeVitonPTFE square section gasket
Bolts materialCr-Mo (standard)NACE (ASTM A193 B7M bolts and A194 2HM nuts)NACE (ASTM A320 L7M bolts and A194 2HM nuts)AISI 316 bolts and AISI 316 nuts, Note 5AISI 630 bolts and AISI 304 nuts
EDD 575 differential pressure transmitter
Fastener(Ex version only)
Zero/ span adj. screw
10
4
ø80
120
45.5
12
6.5
"B"
Cable connection(4th digit)
U-boltM8
"A"
MTG pipeJIS 50A (2B)
4 holesø9 mm
Vent/drain plug
"C"
Cableconnection(4th digit)
11
088
50
70
193
30 58
38
UP
DOWN
Earth terminal(both sides)See table
Higherpressure
Oval flange screwScrew depth 13 mmSee table below
Lowerpressure
51 71 (27)
ø80
22
1
41.3
54
70
120
Details of "A" Details of "B“ Details of "C"Process Conduit ConduitConnection Connection Connection
ø7 ø15 ø13
2.5
8
G
ø18.5 D G1/2
EF
17
With field ind.(option)
Ordering Details
Dimensional Drawings
Symbol Process connection Oval flange screw Earth (4th digit) D E F G terminal
T 1/2 - 14 NPT 16 5 1/4 - 18 NPT 7/16 - 20 UNF No 8 - 32 UNCV PG13.5 8 4.5 1/4 - 18 NPT M10 or M12 M4W M20 x 1.5 16 5 1/4 - 18 NPT M10 or M12 M4X PG13.5 8 4.5 1/4 - 18 NPT 7/16 - 20 UNF M4
Conduit connector
Notes3 Static pressure < 100 bar: M10 bolts
Static pressure 100...140 bar: M12 bolts
4 See table page 2
5 Static pressure max. 100 bar
EDD575 Top view
EDD575 Side view
EDD575 Front view
Data sheet A12.01
Design and specifications subject to change without notice
Sputtered thin film strain gauges
Absolute or gauge pressure
Tough environments
Very reliable
Long term stability
EF0 : 3 mV/V (1 to 600 bar) 2.2 mV/V (for 1000 bar)
Operating temperature: from cryogenic temperature to + 220°C
Technical Data (20°C)
EF0 Pressure transducer
Input voltage 10 Vdc (nominal) to 20 Vdc (max.)
Input impedance 1300 Ω ± 20%
Insulating resistance 100 M Ω / 100 Vdc at 25° C
Output signal 3 mV/Vdc ± 10% typ (± 25% max.) from 1 to 600 bar 2.2 mV/V ± 10% typ (± 25% max.) for M.R. 1000 bar
Output impedance 1250 Ω ± 30%
Initial zero offset ± 1% typ (± 3% max.)(% F.S.)
Global error ±0.2% F.S. typ (±0.30% max.)
Zero thermal shift ±0.005% F.S. typ (±0.01% F.S. max.)
Span thermal drift ±0.01% /°C (max)
Long term stability Zero: ± 0.2% F.S. (typ) over 5 years(at 20°C, atmospheric pressure) ± 0.5% F.S. (max.) over 5 years Span: ± 0.1% F.S. (typ) over 5 years ± 0.2% F.S. (max.) over 5 years
Vibrations specifications 20 g peak, from 5 to 2000 Hz(IEC 68-2-6)
Wetted parts P ≤ 6 bar : 15.5 PH steel + Hastelloy C276* P ≤ 10 bar : 15.5 PH steel* Body 15.5 PH steel*
Temperature ranges Operating -55...+150°C (option from cryogenic T° to +220°C) Compensated -30...+130°C Storage -60...+150°C
Shocks (IEC 68-227 test EA) 100 g - 6 msec - 1/2 sinus
Tightness IP 64 (gauge pressure) IP 65 (absolute pressure)
Pressure port G 1/4 female up to 400 bar AE 250C from 600 to 1000 bar
Tightening torque 10 to 60 Nm (female G 1/4) 35 Nm (AE 250C)
Electrical connection Six pins size 10 bayonet lock connector per MILC 26482G
Weight About 150 g
* 15.5 PH steel : refined version of 17.4 PH.
Design and specifications subject to change without noticeData sheet A12.01
Measuring range 1 to 400 bar
female gas union G 1/4
Measuring range600 to 1000 bar
250C type female adaptor(Autoclave Engineers)
Electrical connection
Top view ofadaptator base
Copper sealHexagon nut22 across flats
Drain
Hexagon nut22 across flats
Cable (2m) + glandOther pressure ports (see below)
Measuring range (M.R.) 1 1.6 2.5 4 6 10 16 25 40 60** 100** 160** 250** 400** 600** 1000**
Max. measurement range 1.2 1.92 3 4.8 7.2 12 19.2 30 48 72 120 192 300 480 660 1200
Max. overrange 2 3.2 5 8 12 20 32 50 80 120 200 320 500 800 1200 1200
Burst pressure 60 70 80 100 120 180 250 350 400 500 800 1000 1500 1800 3000 3000
* Ø 10 x 8, L = 50 mm
** Absolute pressure only
EFO
A + Supply
B + Measurement
C - Measurement
D - Supply
E N.C.
F N.C.
L=65 L=65
G1/4 250C M 14 x 1.5 M 18 x 1.5 M 10 x 1 M 14 x 1.5 G1/2 Smooth* female female male+female male male female male s.s. tube cone 60°
Range (bar) 400 600/1000 400 400 400 400 400 100
Seal copper metal/metal copper 22 x 18.3 x 1.5 8 x 4.2 x 1.5 18 x 14.3 x 1.5 per standard welding 18 x 14.3 x 1.5 18 x 14.3 x 1.5 on tube
L max. 65 90 105 110 105 90 107 -
Dimensions (mm), electrical connections
Options, measuring ranges
Selection table (bar)
Model 1´...3´ digitStandard
Output signal 4´ digitLow level
Hydraulic connection 5´ digitM14 x 150 male (≤ 400 bar)M18 x 150 male (≤ 400 bar)7/16" 20 UNF-3A (≤ 400 bar)G 1/4 H (≤ 400 bar)M14 x 150 female (≤ 400 bar)9/16" 18 UNF-2B (600 and 1000 bar)Tube OD 10 x ID 8, L = 50 ; ≤ 100 bar)G 1/2 (≤ 400 bar)M10 x 100 male (≤ 400 bar)
Pressure range 6´...8´ digitSee codes in table
Pressure type 9´ digitAbsoluteGauge
EF01 x xxxx
EF0
1
A W C R R T X 3 7
xxx
A R
Ordering Details - EF0
B15B16B18B19B20B22B24B26B27B29B31B33B35B38B39B41
code Rangebar
0 + 1 A R 0 + 1.6 A R 0 + 2.5 A R 0 + 4 A R 0 + 6 A R 0 + 10 A R 0 + 16 A R 0 + 25 A R 0 + 40 A R 0 + 60** A 0 + 100** A 0 + 160** A 0 + 250** A 0 + 400** A 0 + 600** A 0 + 1000** A
** Absolute pressure only
UK/
2002
-10
Thi
s da
ta s
heet
may
onl
y be
repr
oduc
ed in
full
Data sheet A12.02Design and specifications subject to change without notice
Technical Data (20°C)
EG51-E101-E111-E801-EY81-EMD1 Pressure transducers
EMD1: The combinaison of bonded foil stain gauges to a quasi flush dia-phragm eliminates friction phenomena, and results in high life cycle, high frequency response, infinite resolution.
EG51: This high pressure transducer has been specially designed to withstand severe industrial applications, where ruggedness is an essential criterium. Its monolithic stainless steel body is equipped with bonded foil metallic strain gages. The high pressure tightness is achieved by metal to metal conic gauges contact.
E101/E111: These pressure transducers are based on a TRANSBAR® sen-sitive element, with ceramic membrane, temperature compensated (E111). They are compatible with the most corrosive fluids.
E801/EY81: A stainless steel monolithic proof body, a cable output on over-moulded cover ensures a resiliency allowing to use them in an industrial environment.
Flush diaphragm (EMD1)All stainless steel (EMD1-EG51-E801/EY81)Bonded foil strain gauges (EMD1)Small size (EMD1)Ceramic TRANSBAR® sensing element (E101/E111)Intrinsically safe version (EY81), approval EEx ia IIc T6
EMD1Rated range 0...10 bar to 0...500 barGlobal error ±0.25% F.S.Signal output 2 mV/V ± 20%Normal power supply 12 VdcWetted parts 1.4542 (17.4 PH)Operating temperature -30...+100°CThermal zero drift ±0.02% F.S./°C (+10...+55°C)Hydraulic connection M18 x 1.5Dead volume 0.1 cm3
EG51Rated range 0...500 bar to 0...5000 barGlobal error ±0.5% F.S.Signal output 10 mV nominalNormal power supply 10 VdcWetted parts 1.4418Operating temperature -40...+80°C
Zero thermal drift ≤ 3% F.S./°C (+10...+55°C)Hydraulic connection M20 x 1.5 up to 2500 bar M16 x 1.5 for 5000 barProtection index IP 64
E101Rated range 0...0.5 bar to 0...400 barPower supply 10 V nominalSignal output 20 to 55 mV up on M.R.Operating temperature -25...+85°CFluid temperature -25...+100°CProtection index IP 66Global error 0.4% F.S.Thermal drift ≤ 2.5%(from -10...+55°C)Wetted parts Stainless steel 1.4404 (316L)le fluide
E111Rated range 0...0.5 bar to 400 barPower supply 10 V Signal output 10 to 40 mV up on M.R.Operating temperature -25...+85°CFluid temperature -25...+100°CProtection index IP 66Global error 0.4% F.S.Thermal drift ≤ 2%(from -10...+55°C)Wetted parts ceramic, viton® o'ring
E801/EY81Rated range 0...2 bar to 500 barPower supply nominal 10 VSignal output 100 mV ± 1%Operating temperature -20...+80°CFluid temperature -20...+80°CProtection index IP 66Global error 0.3% F.S.Thermal drift ≤ 2%(from -10...+55°C)Wetted parts 1.4418
Viton® is registered trademarks of DuPont Dow Elastomers
Design and specifications subject to change without noticeData sheet A12.02
EG51 : optional, adaptator for tube 9.53 x 3.2 or 6.35 x 1.6
EMD1
E801 / EY81 EG51
E101 / E111
Raccord standard acierà olive pour tube ø 6 mm
+ supply Red or 1 Red or A - supply Blue or 3 Green or D + measur. Yellow or 4 Yellow or B - measur. White or 2 White or C
E101-E111-EG51E801 - EY81 EMD1
CONNECTIONSkg
0.250 kg
kg
0.230 kgkg
0.260 kg
kg
0.075 kg
6
Model 1´ digitElectronic
Type 2´...3´ digitE101E111E801EY81EG51EMD1
Signal ouput 4´ digitmV
Hydraulic connection 5´...6´ digitG 1/2 (E101 / E111 / E801)1/2 NPT (E101 / E111)Compression filling with olive for tube Ø 6 mm (E801 / EY81)Female M20 x 1.5 (≤ 2500 bar) (EG51)Female M16 x 1.5 (5000 bar) (EG51)M18 x 1.5 (EMD1)
Pressure range 7´... 9 digitSee codes in tables
Pressure type 10´ digitAbsoluteGauge
Exx1 xx xxxx
E
10 11 80 Y8 G5 MD
1
03 06 Y0 U0 V0 W0
xxx
A R
Dimensions (mm), connections
Ordering Détails - EG51/E101/E111/E801/EY81/EMD1
B99 0.5 (2)
B15 1 (2)
B18 2.5 (2) (3)
B98 5 (2) (3)
B22 10 (2) (3) (4)
B25 20 (2) (3) (4)
B28 50 (2) (3) (4)
B31 100 (2) (3) (4)
B34 200 (2) (3) (4)
B38 400 (2)
B97 500 (3) (4)
B41 1000 (1)
B96 2500 (1)
B46 5000 (1)
Rangebarcode
(1) EG51 (2) E101 / E111(3) E801 / EY81 (4) EMD1
cable length
gland
screen
according to DIN 16288
Red : + supply
Blue : - supply
Yellow : + measurement
White : - measurement
Compression fitting witholive for tube Ø6 mm
length : 109 socked included
2 flats (27 on flats)
length : 133 plug included
UK/
2002
-10
Thi
s da
ta s
heet
may
onl
y be
repr
oduc
ed in
full
Data sheet A12.20Design and specifications subject to change without notice
The TRANSBAR® technology is a spin off of the «thick film technology» used worldwide to produce so called «hybrid electronic circuits».
Patterns of conductive and resistive pasts, or «inks», are deposited on a substrate, generally ceramics, using screen printing techniques.
The uniqueness of the «TRANSBAR®» technology is to use the piezoresistive charac-teristics of specific resistive inks, i.e. the fact that their resistance values vary when submitted to dimensional changes.
These resistors, called strain gauges, judiciously positionned on the deformable structure (diaphragm), are connected together in a four arms Wheatstone bridge configuration.
A regulated voltage source is connected to one diagonal of the bridge. A pressure applied to the diaphragm will deform it and therefore unbalance the bridge, resulting in an electrical signal, on the other diagonal of the bridge, proportional to the applied pressure.
EK (CS) : Open bridge, unbalanced. Bridge impedance :15 k +30%ED (CA) : Closed bridge, balanced. The integrated bridge balancing circuitry eliminates
possible induced parasites due to connections to an external circuit.
EP (CP) : Closed bridge, balanced . Interchangeability : output signal trimmed to ±1%ER (CTi) : Closed bridge, balanced . Thermal drifts compensation : zero and output signal.ET (CT) : Closed bridge, balanced . Thermal drifts compensation : zero and output signal . Interchangeability .
Other models, EC-EL with high level output signal, 0-10 V, or 0-5 V, or 4-20 mA: consult us.
This low level signal, some mV., will have to be amplified to a suitable level to be connected to a display, controller, recorder, PLC or whatever required peripheric equipment.
Constructed entirely of ceramics (Al203, 96 %), comparable to a cristal, these sensors have a quasi perfect mechanical behaviour : good linearity, low hysteresis. They can withstand tens of millions of cycles. Chemically inert, ceramics accepts most industrial media, even aggressive ones.
Their simple geometry allows their easy integration in OEM’s mechanical structures.
The field of their applications is very wide, from basic research to general industry.
Models
EK-ED-EP-ER-ET-EC-EL Pressure Sensors
Measurement of gauge or absolute pressureFrom 250 mbar to 600 bar full scaleCorrosion resistantExcellent long term stabilityLow cost - excellent performances / price ratio
Sectionned wiew
Electrical connections
EK11 / 21(CS1 /2)
ED-EP 11 / 21(CA - CP 1 / 2)
ER-ET 11 / 21(CTi - CT 1 / 2)
ED71 (CA7)
Soldered contacts
Screen printed gauges
Ceramic diaphragm
1 + Exc.
4 - Exc.3 - Signal
2
5+ Signal
1 + Exc.
4 - Exc.3 - Signal
5 + Signal
1 + Exc.
4 - Exc.2 - Signal
3 + Signal
+ Supply
- Supply
+ Supply
- Supply
+ Supply
- Supply
Design and specifications subject to change without noticeData sheet A12.20 Data sheet A12.20
Design and specifications subject to change without noticewww.bourdon-haenni.com
Page 3
SERIE 1 - Ø 42 mm - Low pressure ranges
SERIE 2 - Ø 34 mm - Low, medium and high pressure ranges
Technical Data (20°C)
MODELS SPECIFICATIONS EK11 - ED11 - EP11 - ER11 - ET11RANGE IDENTIFICATION : RB (1) RC (1) RD RE RGRATED RANGE (R.R.) : (bar) 0.2 0.5 0.75 1.5 2 (≅ psi) 2.9 7.25 10.9 21.75 29 Max. admissible pressure, without derating of specs : (bar) 0.22 0.55 0.83 1.65 2.2Burst pressure : (bar) ≥ 0.4 ≥ 1 ≥ 1.5 ≥ 3 ≥ 4OUTPUT SIGNAL AT RATED RANGE: (2) (mV) EK11 (±30%) 24 47 45 67 54 ED11 (±30%) 22 45 42 63 50 EP11 (±1%) 18 35 35 45 40 ER11 (±30%) 20 40 38 55 45 ET11 (±1%) 15 30 30 40 30GLOBAL ERROR (max.) : (% R.R.) 1 0.4 0.4 0.4 0.4(non linearity + hysteresis + repeatability)
DIMENSIONS See fig. 1
(1) Gauge pressure only.
SPECIFICATIONS : ALL MODELS EK11 ED11 EP11 ER11 ET11EXCITATION VOLTAGE : Nominal : (Volt) 10 10 10 10 (3) 10 (3)Maximum : (Volt) 30 30 30 10 (3) 10 (3)
BRIDGE IMPEDANCE Input : (kOhm) 15 ≥ 6 ≥ 6 ≥ 6 ≥ 6Ouput : (kOhm) 15 15 10 15 10
TEMPERATURE LIMITS : Operating : (°C) -55 to +125 -55 to +125 -55 to +125 -55 to +125 -55 to +125 Compensated : (°C) n.a. n.a. n.a. -10 to +55 -10 to +55
THERMAL DRIFTS : (2) Zero : (µV / °C) ≤ ±30 ≤ ±30 ≤ ±30 ≤ ±6 ≤ ±6Output signal : (% / °C) -0.04 -0.04 -0.04 ≤ ± 0.01 ≤ ± 0.01
LONG TERM ZERO DRIFT : (% R.R. / year) ≤ ± 0.2 (non cumulative)
INITIAL ZERO UNBALANCE (2) (mV) ≤ ± 500 ≤ ± 2 ≤ ± 2 ≤ ± 1 ≤ ± 1
(2) Under nominal excitation voltage : 10 V (3) 5 V. optional.
MODELS SPECIFICATIONS EK21 - ED21 - EP21 - ER21 - ET21RANGE IDENTIFICATION : MB MC LC LE LI LL LR HR ER* EZ* EP*RATED RANGE : (R.R.) : (bar) 0.6 1 2 5 10 20 50 100 200 350 400 (≅ psi) 9 15 30 75 150 300 750 1500 3000 5250 6000Max. admissible pressure, without derating of specs : (bar) 0.66 1.1 2.2 5.5 11 22 55 110 220 385 440Burst pressure : (bar) ≥1.8 ≥3 ≥6 ≥12 ≥25 ≥50 ≥125 ≥250 ≥450 ≥550 ≥600OUTPUT SIGNAL AT RATED RANGE : (2) (mV) EK21 (±30%) 27 35 51 65 70 70 70 70 65 47 35 ED21 (±30%) 25 33 47 60 65 65 65 65 60 45 30 EP21 (±1%) 20 27 40 50 50 50 50 50 50 35 20 ER21 (±30%) 24 27 37 48 52 52 52 52 48 36 24 ET21 (±1%) 18 20 27 40 40 40 40 40 40 20 15GLOBAL ERROR (max.) (% R.R.) 0.8 0.4 0.4 0.4 0.3 0.3 0.2 0.2 0.2 0.4 0.4(non linearity + hysteresis + repeatability)
DIMENSIONS See fig. 2
Models with* : absolute pressure only.
SPECIFICATIONS : ALL MODELS EK21 ED21 EP21 ER21 ET21EXCITATION VOLTAGE : Nominal : (Volt) 10 10 10 10 (3) 10 (3)Maximum : (Volt) 30 30 30 10 (3) 10 (3)
BRIDGE IMPEDANCE : Input : (kOhm) 15 ≥ 6 ≥ 6 ≥ 6 ≥ 6Ouput : (kOhm) 15 15 10 15 10
TEMPERATURE LIMITS : Operating : (°C) -55 to +125 -55 to +125 -55 to +125 -55 to +125 -55 to +125 Compensated : (°C) n.a. n.a. n.a. -10 to +55 -10 to +55
THERMAL DRIFTS : (2) Zero : (µV / °C) ≤ ±30 ≤ ±30 ≤ ±30 ≤ ±6 ≤ ±6Ouput signal : (% / °C) -0.04 -0.04 -0.04 ≤ ± 0.01 ≤ ± 0.01
LONG TERM ZERO DRIFT : (% R.R. / year) ≤ ± 0.2 (non cumulative)
INITIAL BRIDGE UNBALANCE : (2) (mV) ≤ ± 500 ≤ ± 2 ≤ ± 2 ≤ ± 1 ≤ ± 1
(2) Under nominal excitation voltage 10 V (3) 5 V optional.
Design and specifications subject to change without noticeData sheet A12.20www.bourdon-haenni.com
Page 2Data sheet A12.20
Design and specifications subject to change without notice
Model e : mm identification ± 1 %
RB 5.30 RC 5.35 RD 5.40 RE 5.45 RG 5.55
Model e : mm Identification ± 1 %
MB 6.30 MC LC 6.35 LE 6.45 LI 6.625 LL 6.85 LR HR ER 7.30 EZ 8.05 EP 8.55
Figure 1
Series 1
Figure 2
Series 2
Figure 3
Tightening force loading area (ø 40)
Ventilation hole (gaugepressure measurement)
Range identificationTightening force loading area (ø 30)
Connecting pads2.54 mm pitch
Ventilation hole (gaugepressure measurement)
Option : ZITEX humidity protector (gauge pressuremeasurement only)
Tightening force loading area (ø 15)
Range identification
Connecting pads2.54 mm pitch Option : ZITEX humidity protector
(gauge pressure measurement only)
e
e
Model e : mm Identification ± 1 %
FA 6.25 FB DB 6.30 FE DE 6.45 DG CG 6.55 DL CL 6.85 CQ 7.05 CR 7.30 CU 7.65 CZ 7.82
Series 7
Connecting pads2.54 mm pitch
1 Excit.2 Signal3 Signal4 Excit Option : ZITEX humidity protector
(gauge pressure measurement only)
Ventilation hole (gaugepressure measurement)
SERIE 7 - Ø 18 mm - Low, medium and high pressure ranges
Technical Data (20°C)
Dimensions
SPECIFICATIONS ED71RANGE IDENTIFICATION : FA FB DB FE DE DG CG DL CL CQ CR CU CZ RATED RANGE : (R.R.) (bar) 2 4 6 10 16 25 40 60 100 160 250 400 600 (≅ psi) 30 60 90 150 250 350 600 900 1500 2500 4000 6000 -Max. admissible pressure, without derating of specs : (bar) 5 8 12 20 32 50 80 120 200 320 500 800 800Burst pressure : ≥ (bar) 7 12 18 30 48 75 120 180 300 480 600 - 1000OUTPUT SIGNAL AT R.R. : (1) ±30% (mV) 20 20 20 20 22 22 25 22 25 27 25 30 25
GLOBAL ERROR : (% R.R.) ≤ 0.4 ≤ 0.6(non linearity + hysteresis + repeatability)EXCITATION Nominal : (Volt) 10Maximum : (Volt) 20BRIDGE IMPEDANCE Input : (kOhm) Closed bridge : ≥ 6Output : (kOhm) ≥ 6TEMPERATURE LIMITS Operating : (°C) -55 to +125Compensated : (°C) n.a. THERMAL DRIFTS Zero : (µV / °C) ≤ ±30 Output signal : (% / °C) ± 0.01
LONG TERM ZERO DRIFT : (% R.R. / year) ≤ ± 0.2 (non cumulative)
INITIAL ZERO UNBALANCE (1) (mV) ≤ 2
DIMENSIONS See fig. 3
(1) Under nominal excitation voltage : 10 V
Design and specifications subject to change without noticeData sheet A12.20
Particular technical specificationsZitex humidity protector (gauge pressure models only)Polyester flat cable, 5 wires, 50 mm soldered on sensors serie 1 or 2Kapton flat cable, 4 wires, 25 mm. Standard for ED71 (soldered).Flexible single wires, soldered on sensor, length to be specifiedAll other options : please consult us.
Above described pressure sensors address OEM users, taking in charge the electronic conditioning of the sensor (excitation, signal amplification) depending upon their actual needs.
For those who would not have such capacities, or for whom, the annual requirement would not allow a satisfying playback on the cost of develop-ment of such electronic circuitry, BOURDON-HAENNI can supply sensors associated with p.c. boards usually fitted in transmitters, delivering a normalised high level output signal for the rated range : 4-20 mA, 1-5 V, 0-10V, directly usable by peripheric equipments as : displays, recorders, controllers, P.L.C.s, etc.
Be careful : Max. operating temperature range is limited to 70°C for absolute pressure versions.
Options
Model 1´ digitPressure sensors
Type 2´...4´ digitSerie 1 - Ø 42 mm
Serie 2 - Ø 34 mm
Serie 7 - Ø 18 mm
Pressure range 5´...6´ digitSee codes in tables
Pressure type 7´ digitAbsoluteGauge
Exxx xx x
E
K11 D11 P11 R11 T11 K21 D21 P21 R21 T21 D71
xx
A R
Pressure sensors, high level output signal models EC - EL
Ordering Details - EK-ED-EP-ER-ET
FAFBDBFEDEDGCGDLCLCQCRCUCZ
RBRCRDRERG
code Range bar
0.2 – R 0.5 – R 0.75 A R 1.5 A R 2 A R
MBMCLCLELILLLRHREREZEP
code Range bar
0.6 A R 1 A R 2 A R 5 A R 10 A R 20 A R 50 A R 100 A R 200 A – 350 A – 400 A –
code Range bar
2 A R 4 A R 6 A R 10 A R 16 A R 25 A R 40 A R 60 A R 100 A R 160 A R 250 A R 400 A R 600 A R
Serie 1 - Ø 42 mm
Serie 2 - Ø 34 mm
Serie 7 - Ø 18 mm
UK/
2002
-10
Thi
s da
ta s
heet
may
onl
y be
repr
oduc
ed in
full
Design and specifications subject to change without noticeData sheet A11.02
These pressure transmitters with a stainless steel housing use a very high stability capacitive ceramic sensor to give a rugged and highly reliable product.
They are particularly suited for measuring low pressures in a variety of industrial applications and are compatible with the harshest of process fluids. Applications include : control of process fluids, continuous pressure monitoring and OEM applications.
Calibration of sensor with certificate : Q1060
Additional length of cable
Other measurement ranges in case of high over pressure : please refer to us
Capacitive ceramic sensor
Measurement of pressure and vacuum; absolute or gauge pressure
Measurement ranges: from -100...+100 mbar to 0...+600 mbar
Extremely resistant to over pressure
Analogue output 4-20 mA, by DIN 43650 connector (IP65) or cable output (IP68) (option)
Transmitter in stainless steel (1.4401/AISI 316)
Conforms to European CE Directive (89/336/CEE)
Technical Data (20°C)
EN113 Low pressure transmitters
Measurement range -100...100 mbar to -1...9 bar 0...25 mbar to 0...600 mbar
Output signal 4...20 mA
Supply voltage 11...32 Vdc
Insulation > 100 MΩ at 500 Vdc
Maximum input current 50 mA
Load impedance Rc = (Vsupply - 11V) / 20 mA
CE -conformity Standards EN50082-1 and 2 (immunity) Standards EN50081-1 and 2 (emission) Cabling : screened cable, earthing terminal connected to case
Pressure standards 97/23/CE
Global error (linearity, hysteresis and repeatability) by reference to BFSL Max.: ±0.2% of F.S.
Operating temperature Ambient (Ta) -25...+85°C Fluid -25...+100°C (Ta ≤ 50°C)
Storage temperature -40...+85°C
Compensated temperature range (zero and sensitivity) -10...+55°C
Zero thermal drift All pressures : typically 0.015% of F.S./°C
Thermal variation of sensitivity Max : ±0.01% of F.S./°C
Materials in contact with the fluid Ceramic + stainless steel 1.4401 (AISI 316) + FKM Viton® (standard)
Connections Electrical: DIN 43650 connector (standard) Option : cable output (5 m of cable)
Pressure: G1/2
Degree of protection IP65 (DIN connector)(EN 60529) IP68 (cable output)
Typical response time ≤ 100 ms
Vibrations resistance ±1.6 mm (2 - 25 Hz), 4 g (25 - 100 Hz)(IEC 68-2-6)
Zero adjustment ±5% of F.S.
Options
Uncoded (have to be listed after the code number)
Design and specifications subject to change without noticeData sheet A11.02
Dimensions (mm) - connections
Pressure ranges
Ordering Details - EN113
UK/
09-2
002
Thi
s da
ta s
heet
may
onl
y be
repr
oduc
ed in
full.
Cable output 4-20 mA red + supply
black – supply
ground
DIN connector
4-20 mA 1 + supply 2 – supply
3 not connected ground
Standard version(connector output)
Option(cable output)
Pressurerange
vacuum and pressure — — — — — -100 +100 mbar — -200 +200 mbar — -1 +1 bar -1+3 bar -1 +9 bar
pressure 0 +25 mbar 0 +40 mbar 0 +100 mbar 0 +160 mbar 0 +200 mbar — 0 +250 mbar 0+400 mbar 0+600 mbar — — —
Max. permissible pressure 4 bar 4 bar 4 bar 6 bar 6 bar 4 bar 6 bar 6 bar 10 bar 6 bar 25 bar 40 bar
N2HN3MN05N06N08N09N93N10N11N12
code measurement range in mbar.
Vacuum and pressure
-1 + 1 - R -1 + 3 - R -1 + 9 - R
code measurement range in bar.
Vacuum and pressure
-100 + 100 - R -200 + 200 - R 0 + 25 - R 0 + 40 - R 0 + 100 - R 0 + 160 - R 0 + 200 A R 0 + 250 A R 0 + 400 A R 0 + 600 A R
B73B76B79
Model 1´...4´ digitLow pressure Output signal 5´ digit
4...20 mA
Hydraulic connection 6´...7´ digitG 1/4G 1/2 standard1/2 NPT Sensor seal 8´ digit
NBR (Nitrile)EPDMFKM (Viton®) standard Pressure range 9´...11´ digit
See codes in table Pressure mode 12´ digit
AbsoluteGauge
Viton® is registered trademark of DuPont Dow Elastomers
EN113 xx x xxx x
EN11 3
02 03 06
3 5 9
xxx
A R
PM 050Hygienic process weld-in sleeve
The hygienic process weld-in sleeve PM 050 is the process sleeve for the hygienic range. By means of the metallic or PEEK sealing cone in accordance to EHEDG a hygiene standard installation is possible. It's used in combination with the process pressure sensor PSC 050 and the inductive conductivity sensor ISL 050. Application possibilities are in all hygienic product ranges (drinks, beer, dairy products, pharmacy etc.).
hygiene standard installation (EHEDG, FDA) defined position of the cable gland or of the M12 plug metallic sealing system no-problem weld-in
Product Information
Product Description
NoticeNoticeNoticeNotice
Technical DataTechnical DataTechnical DataTechnical Data
Material stainless steel V4A 1.4571Thread system hygienic G1"hFitting weld-inNominal diameter Ø 50 mm x 23 mmSealing system metallic; PEEKOperating pressure max. 16 bar
211201 FE
Order code
PM 050
Wiring Diagram
Order Code
Dimensional Drawing
PM 050 Hygienic process weld-in sleeve €
211201 FE
Capacitice Pressure Sensor
The front flush ceramic pressure sensor PSC 050 with a stainless steel connecting head is used when there are high hygienic demands (e. g. in breweries, dairies, in the drinking and pharmaceutical industry). The applications for the PSC 050 are tank level measurement utilizing the hydrostatic principles and also the relative and absolute pressure measurement.The front flush ceramic sensor is ideal for applications in corrosive and abrasive media. The hygienic installation is guaranteed by using the hygienic process weld-in sleeve PM 050. Due to its high temperature resistance (130 °C), the PSC 050 is well suitable for CIP and sterilization processes.
• Measuring cell is oil-free, front flush and made of ceramic• Compact design in stainless steel• High overload resistance• Best resistance against corrosion and abrasion• CIP and SIP capable• Cable gland has defined position• Hygienic adapter sleeves for other process connections• Turn-Down 1:4
Product Information
Product Description
NoticeNoticeNoticeNotice
Technical DataTechnical DataTechnical DataTechnical Data
PSC 050
Connecting head stainless steel V2A 1.4305; Ø 55 mmElectrical connection cable gland M16; M12 plugProcess connection thread adapter G 1"; sleeve PM 050Membrane ceramic AL2O3Type of protection IP 67Pressure range 0,2 / 0,4 / 1,0 / 2,0 / 4,0 / 10 / 20 bar rel.Overload resistance 10 timesTemperature range −20 °C...+130 °C (140 °C < 1 h)Output 4...20 mA current loopAccuracy ≤ ±0,1 % of full scaleTemperature drift ≤ ±0,005 % / KAuxiliary voltage 14...30 V DC
261101 FE
Measuring range
Electrical connection
Display
PSC 050
Wiring Diagram
Order Code
Accessories
Dimensional Drawing
PM 050
1 0...0,2 bar 2 0...0,4 bar 3 0...1,0 bar 4 0...2,0 bar 5 0...4,0 bar 6 0...10 bar 7 0...20 bar
1 cable gland M16 2 plug M12
Hygienic process weld-in sleeve
261101 FE
Design and specifications subject to change without notice
Data sheet A11.10
X910 1/2 NPT conduit fitting with wires output
Measurement of vacuum, absolute or gauge pressureTRANSBAR® ceramic technology (X910)Thin film technology (X510)Zero adjustment as standard (±10% of range)Modularity of hydraulic connectionsLCIE EEx d IIC T5/T6 CENELEC, CSA, CSA US, FM approvalsConforms to European EMC Directive, CE marked
X910 internal terminal stripwith cable gland
Technical Data (20°C)
X910-X510 Explosion-proof pressure transmitter
Measurement range X910 0...25 mbar to 0...400 bar compound, gauge pressure (A,G) X510 0...60 bar to 0...1800 bar pressure (A,G)
Output signal X912-X512: 0...10 Vdc. X913-X513: 4...20 mA (except -1...0 bar where -1 = 20 mA, 0 = 4 mA) X914-X514: 1...5 Vdc. X916-X516: 0...20 mA
Supply voltage X912-X512: 14...40 Vdc X913, X914-X513, X514: 11...40 Vdc.
X916-X516: 8...40 Vdc Option Low voltage: 8...32 Vdc (X913,X914-X513,X514)
Insulation > 100 MΩ at 250 Vdc
Maximum input current X912, X914-X912, X914: 6 mA X916-X516: < 25 mA
Load impedance (+M / –M) X912-X512: ≥ 2.5 k Ω X914-X514: ≥ 1 k Ω X913-X513: RΩ ≤ (Usupply-11)/0.02 X913-X513: RΩ ≤ (Usupply-8)/0.02 (low voltage option ) X916-X516: RΩ ≤ (Usupply-6)/0.02
Global error (linearity, hysteresis and repeatability) by reference to BFSL X910: Typically: ±0.2% of F.S. / Max.: ±0.3%F.S.
For P ≤ 60 mbar: Typically: ±0.6% of F.S. / Max.: ±1%F.S. X510: Typically: ±0.2% of F.S. / Max.: ±0.3%F.S.
Operating temperature Ambient (Ta) X910-X510 -25...+40°C (T6 approval) -25...+70°C (T5 approval) Fluid -25...+100°C (Ta ≤ 50°C)
Storage temperature -40...+85°C
Compensated temperature range (zero and sensitivity) -10...+55°C. Option: -10...+70°C
Zero thermal drift ±0.025% FS/°C max. (except P 1 bar : ±0.06% F.S./°C) Option ±0.015% FS/°C max. (except P 1 bar : ±0.025% F.S./°C)
Span thermal drift X910: Typically: ±0.01% /°C max. : ±0.015% /°C X510: Typically: ±0.04% /°C option : ±0.01% /°C
Wetted parts X910: Ceramic + 1.4404 (316L) stainless steel + NBR seal for P 250 mbar and FKM seal for P < 250 mbarX510: 17-4 PH stainless steel + 1.4404 (316L) stainless steel
Standard connections Electrical: internal terminal strip with cable gland 1/2 NPT conduit fitting with wires output (length 1.5 m) Pressure: G 1/2, 1/2 NPT (other : contact us) Mounting on chemical seals available
CE -conformity Standards EN50082-1 and -2 (immunity) Standards EN50081-1 et -2 (emission) with
sreened cable, screen connected ar both ends Pressure standards 97/23/CE
Protection rating (EN 60529) IP65
Vibration resistance (IEC 68-2-6) 1.5 mm (10 - 55 Hz), 20 g (55 Hz - 2 kHz)
Shock resistance (IEC 68-2-32) 25 falls from 1 m on concrete ground
The X910 and X510 pressure transmitters allow pressure measurements on most corrosive fluids, in hazardous areas.
They are available in a G 1/2 or 1/2 NPT pressure port to be used on low viscosity fluids, or mounted on chemical seals (option) well suited for appli-cation on viscous and cristallizing fluids.
Two electrical outputs are available : internal terminal strip with cable gland or 1/2 NPT conduit fitting with wires output.
Design and specifications subject to change without notice
Data sheet A11.10
Design and specifications subject to change without notice
Data sheet A11.10www.bourdon-haenni.com
Page 3
1/2 NPT
27
23
139
Ø 65
Ø 37,7
X910 for P ≥ 1 barinternal terminal strip with cable gland
Blocking screwCHC M3
Second optional input with top
Access to adjustmentsCHC 1/8 NPT
Certified EEx d IIc cable gland.
1/2 NPT standard. option : 3/4 NPT, G1/2, M20x1.5
X910 for P < 1 barinternal terminal strip with cable gland
Ø 49, P < 250 mbar
27
162
Ø 37,7
Ø 41,1
X913
1 : +A2 : - A3 : : Ground
X912-X914-X916
1 : +M2 : - A / - M3 : +A : Ground
Connections
1.500 1.600kg kg
Dimensions (mm), connections
Design and specifications subject to change without notice
Data sheet A11.10www.bourdon-haenni.com
Page 2 Design and specifications subject to change without notice
Data sheet A11.10
X910 for P ≥ 1 bar1/2 NPT conduit fitting with wires output
X910 for P < 1 bar1/2 NPT conduit fitting with wires output
X510internal terminal strip with cable gland
X5101/2 NPT conduit fitting with wires output
27
1/2 NPT
110
1/2 NPT
27
Ø 37,7
Ø 49, P < 250 mbar
27
133
Ø 41,1
Ø 37,7
139
23
Ø 65
Ø 37,7
27
1/2 NPT
110
1/2 NPT
27
Ø 37,7
X513
1 : +A2 : - A3 : : Ground
X512-X514-X516
1 : +M2 : - A / - M3 : +A : Ground
Connections
Connections
X512-X514-X516
+M : White- A / - M : Black+A : Red : Green/Yellow
X513
+A: Red- A: Black : Green/Yellow
Connections
X912-X914-X916
+M : White- A / - M : Black+A : Red : Green/Yellow
X913
+A: Red- A: Black : Green/Yellow
3 AWG-22 wireslength 1.5m
0.700
Certified EEx d IIc cable gland.
1/2 NPT standard. option : 3/4 NPT, G1/2, M20x1.5
1.500
0.600
0.600
kg kg
kg kg
Design and specifications subject to change without notice
Data sheet A11.10
DegreasedLightning protectionLow supply voltage (see specifications on page 1)Compensated temperature range (- 10...+ 70°C)Zero thermal drift: ±0.015% of range/°C max.Span adjustment ±10% of rangeSpan adjustment ±50% of range for 0.25 < P < 1600 barCalibration of sensor with certificate: Q1060Other hydraulic connectionsAdditional length of wiresOther units: kPa (code D), MPa (code E), kg/cm² (code F), psi (code H), mbar (code N)
Options
Model 1´ digitExplosion-proof pressure transmitter
Type 2´...3´ digitCeramic technologyThin film technology
Output signal 4´ digit0...10 Vdc4...20 mA1...5 Vdc0...20 mA
Hydraulic connection 5´...6´ digitG 1/21/2 NPT
Sensor seal 7´ digitNo sensor seal (X510)NBR (nitril) (standard P 250 mbar)FKM (Viton®) (standard P < 250 mbar)
Pressure range 8´...10´ digitSee codes in tables
Pressure type 11´ digitAbsoluteGauge
Electrical connection 12´ digitInternal terminal strip with cable gland 1/2 NPT (specify for other dimension and second input with top)
1/2 NPT conduit fitting with wires output
Viton® is registered trademarks of DuPont Dow Elastomers
Xx1x xxx xxx x x
X
91 51
2 3 4 6
03 06
0 3 9
xxx
A R
1 2
Measuring Ranges (bar)
Ordering Details - X910
Uncoded Options (have to be listed after the code)
X910 Pressure in mbar Pressure in bar
Compound Pressure — — — — — — — — -1+0 -1+0.6 -1+1.5 -1+3 -1+5 -1+9 -1+15 -1+24 -1+39 — — — — —
Pressure 25 40 60 100 160 250 400 600 1 1.6 2.5 4 6 10 16 25 40 60 100 160 250 400
Measurement range 27.5 44 66 110 175 275 440 660 1.1 1.75 2.75 4.4 6.6 11 17.6 27.5 44 66 110 176 275 440
Max. over pressure 110 110 275 500 500 1000 1000 1000 3 3 4 8 12 20 32 50 80 120 200 320 500 600
Burst pressure 200 200 500 1000 1000 2000 2000 2000 6 6 7 12 18 30 48 75 120 180 300 480 600 800
X510 Pressure in bar
Pressure 60 100 160 250 400 600 1000 1600 1800
Measurement range 66 110 176 275 440 660 1100 1760 1980
Max. over pressure 200 200 320 500 800 800 2000 2100 2100
Burst pressure 400 400 640 1000 1600 2500 2500 2500 2500
Range in mbar
N05N06N07N08N09N10N11N12
code
0 + 25 – R x 0 + 40 – R x 0 + 60 – R x 0 + 100 – R x 0 + 160 – R x 0 + 250 A R x 0 + 400 A R x 0 + 600 A R x
X910 X510
B59B72B74B76B77B79B81B82B1LB15B16B18B19B20B22B24B26B27B29B31B33B35B38B39B41B42B1F
code-1 + 0 – R x-1 + 0.6 – R x-1 + 1.5 – R x-1 + 3 – R x-1 + 5 – R x-1 + 9 – R x-1 + 15 – R x-1 + 24 – R x-1 + 39 – R x 0 + 1 A R x 0 + 1.6 A R x 0 + 2.5 A R x 0 + 4 A R x 0 + 6 A R x 0 + 10 A R x 0 + 16 A R x 0 + 25 A R x 0 + 40 A R x 0 + 60 A R x x 0 + 100 A R x x 0 + 160 A R x x 0 + 250 A R x x 0 + 400 A R x x 0 + 600 A R x 0 + 1000 A R x 0 + 1600 A R x 0 + 1800 A R x
Range in bar X910 X510
UK/
2002
-10
Thi
s da
ta s
heet
may
onl
y be
repr
oduc
ed in
full
Design and specifications subject to change without notice
Data sheet A11.11
Measurement of vacuum, absolute or gauge pressure
TRANSBAR® ceramic technology
Zero adjustment as standard (±10% of range)
Welded construction – reinforced product
Modularity of electrical and hydraulic connections
Highly resistant to severe process conditions (≥ 107 pressure cycles)
Marine version (Bureau Veritas ...)
LCIE 02 ATEX 6133X
The Y910 pressure transmitters allows pressure measurements on most cor-rosive fluids, in hazardous areas.
Technical data (20°C)
Y910 Intrinsically Safe Pressure Transmitter
Measurement range From 0...25 mbar to 0...600 bar Compound, gauge or absolute pressure
Output signal Y912: 0...10 Vdc. Y913: 4...20 mA (except -1...0 bar where -1 = 20 mA, 0 = 4 mA)
Y914: 1...5 Vdc. Y916: 0...20 mA
Supply voltage Y912: 14...28 Vdc Y913-Y914: 11...28 Vdc Y916: 8...28 Vdc Option Low voltage: 8...28 Vdc (Y913, Y914)
Power supply electrical parameters device must be: Usupply ≤ 28 Vdc ; I ≤ 120 mA ; P ≤ 0.8 W
See drawings overleaf for more details.
Insulation > 100 MΩ at 500 Vdc
Maximum input current Y912-Y914: 6 mA Y916: < 25 mA
Load impedance (+M / –M) Y912: ≥ 2.5 k Ω Y913: RΩ ≤ (Usupply-11)/0.02 ; Rc min = 200 Ω Y913: RΩ ≤ (Usupply-8)/0.02 (low voltage option) Y916: RΩ ≤ (Usupply-6)/0.02 ; Rc min = 100 Ω
CE Conformity CEM Directive 89/336/CE (EN50082-1 and -2, EN50081-1 and -2) with screened cable, screen connected at both ends.
Pressure Directive 97/23/CE : 3.3 for P < 200 bar and cat 1 for P ≥ 200 bar.
ATEX Directive 94/9/CE (EN50014, EN50020, EN50281-1-1).
Global error (linearity, hysteresis and repeatability) by reference to BFSL Typically: ±0.2% of F.S. / Max.: ±0.3% of F.S. For P ≤ 60 mbar and P= 600 bar: Typically: ±0.6% of F.S. / Max.: ±1% of F.S.
Operating temperature Ambient (Ta) -25...+75°C Ta = +40°C G: T6 D IP65 : T°surface = +80°C Ta = +75°C G: T5 D IP65 : T°surface = +95°C (G = Gas ; D = Dust) Fluid -25...+100°C (Ta ≤ 50°C) depending on class
Storage temperature -40...+85°C
Compensated temperature range (zero and sensitivity) -10...+55°C. Option: -10...+70°C
Zero thermal drift ±0.025% F.S./°C max. (except P ≤ 1 bar: ±0.06% F.S./°C) Option: ±0.015% F.S./°C max. (except P ≤ 1 bar: ±0.025% F.S./°C)
Span thermal drift Typically: ±0.01%/°C / Max.: ±0.015%/°C
Wetted parts Ceramic + stainless steel 1.4404 (316L) + NBR seal (standard) for ranges > 250 mbar and Viton® for ranges ≤ 250 mbar
Standard connections Electrical: DIN 43650 connector Pressure: G1/2 Many options available
Protection rating (EN 60529) Standard: IP65 (DIN connector) Option: IP67 or IP68 (depending on connection)
Typical response time ≤ 3 ms
Vibration resistance (IEC 68-2-6) 1.5 mm (10-55 Hz), 20 g (55 Hz to 2 kHz)
Shock resistance (IEC 68-2-32) 25 falls from 1 m on concrete ground
CE 0081
I M1 G and D EEx ia I
II 1 G and D EEx ia IIC T6 or T5
Hazardous area: Area 0, 1, 2, 20, 21, 22
Design and specifications subject to change without notice
Data sheet A11.11
Design and specifications subject to change without notice
Data sheet A11.11www.bourdon-haenni.com
Page 3
G1/2
20
Ø 41,1
117
98
Ø 49, P < 250 mbar
27
Ø 27
Standard version. P ≥ 1 barDIN 43650 plug
Ø 35
Ø 27
96
67
10
Ø6 ... Ø8
G1/2
20
S
Z
3
2 1
27
Standard version for P < 1 barDIN 43650 plug
Version also used for -1...0 bar and 0...1 bar ranges with ±50% span adjustment option.
Y913
1 : +A2 : - A3 : : Ground
Y912Y914Y916
1 : +M2 : - A / - M3 : +A : Ground
Connections
0.4000.300
Option : Stainless steel surface mounting brackets
Access to adjustments
41.5
BOURDON HAENNI
kg kg
Ø 27
87 [
108]
72 [
93]
10
Ø6,5
27
Option 23Pig tail (length 1.5 m) + PG7 Cable gland
Option 22Pig tail (length 1.5 m)
Connections
0.350 [0.450] 0.350 [0.450]
Y913
+A : White- A : Blue : Ground
Y912-Y914-Y916
+M : Yellow- A / - M : Blue+A : Red : Ground
Option 08DIN 43650C micro plug (8 mm)
10
67 [
98]94
[11
5]
Ø 27
28
Ø4 ... Ø6
3
2 1
27
Connections
Y913
1 : +A2 : - A3 : : Ground
Y912-Y914-Y916
1 : +M2 : - A / - M3 : +A : Ground
0.250 [0.350]
Ø 27
72 [
93]
10
Ø6,5
27
Connections
Y913
+A : White- A : Blue : Ground
Y912-Y914-Y916
+M : Yellow- A / - M : Blue+A : Red : Ground
kg kg kg
Installation instructions
[xx] : dimensions and weight for "P < 1 bar" versions.
Dimensional Drawings (mm) - Mounting Details
Hazardous areaArea: 0, 1, 2, 20, 21, 22
Umax = 28 VdcImax = 120 mAP = 0,8 WCa > Ci + Ccable
La > Li + Lcable
Ci = 30 nF (Y913 - Y916)Ci = 60 nF (Y912 - Y914)
Don’t forget the barrier’s resistors in the determination of Rc1.In area 0 or 20, the loop calcula-tion of the association transmit-ter with safety barrier must be approved by notified organism.
Certified safety barrier
Non hazardous area
Screen
Screen
Supply
Supply
Design and specifications subject to change without notice
Data sheet A11.11www.bourdon-haenni.com
Page 2 Design and specifications subject to change without notice
Data sheet A11.11
Ø6 ... Ø8
Ø 38
107
[128
]
61 [
82]
10
1
2
3
4
5
6
27
Connections
Y912-Y914-Y916
+M : Yellow- A / - M : Blue+A : Red : Ground
Y913
+A: White- A: Blue : Ground
104
[125
]
71,5
[92
,5]
1011
1/2 NPT Ø6,5
27
27
Ø27
Y913
1 : +A2 : - A3 : : Ground
Y912-Y914-Y916
1 : +M2 : - A / - M3 : +A : Ground
Connections
0.350 [0.450] 0.400 [0.500]
Ø 27
10
72 [
93]
89 [
110]
A
B
F E
D
C
27
85 [
106]
43
72 [
93]
10
27
4
1 2
3
Connections
Y912-Y914-Y916
A : +AB : - A / - MC : +MD :E : GroundF :
Y913
A : +AB : C : - AD :E : GroundF :
Connections
Y912-Y914-Y916
1 : +A2 : +M3 : Ground4 : - A / - M
Y913
1 : +A2 : 3 : Ground4 : - A
0.250 [0.350] 0.300 [0.400] 0.400 [0.500]
Connections
Y913
+A : White- A : Blue : Ground
Y912-Y914-Y916
+M : White- A / - M : Blue+A : Red : Ground
1065
[86
]
Ø 6,5
27
kg kg
kg kg kg
Dimensional Drawings (mm) - Mounting Details[xx] : dimensions and weight for "P < 1 bar" versions.
Option 20terminal strip outlet + screwed cap
Option 54Pig tail cable outlet with 1/2 NPT male (length 1.5 m)
1 : Plug2 : Case3 : Seal4 : Connector5 : Nut6 : PG7 Cable gland (horizontal or vertical)
Optional accessory
Option 096 contacts HE302 plug
Option 24M12, 4 contacts plug
Option 27Submersible cable (length 1.5 m)
Cab
le le
ngth
Design and specifications subject to change without notice
Data sheet A11.11
Options
Uncoded Options (have to be listed after the code)DegreasedLightning protectionMarine versionLow supply voltage(1)
Compensated temperature range (- 10...+70°C)Zero thermal drift: ±0.015% of range/°C max.Span adjustment ±10% of rangeSpan adjustment ±50% of range (except for ranges ≤ 0...+0.25 bar and 0...+600 bar) Calibration of sensor with certificate: Q1060Thread lockingOther hydraulic connectionsAdditional length of cableStainless steel surface mounting brackets Other units: kPa (code D), MPa (code E), kg/cm² (code F), psi (code H), mbar (code N)Atmospheric pressure measurement (Range: 800...1200 mbar absolute)
Coded Options
Other electrical connections: 08.DIN 43650C micro plug (IP65 (2)) 22.Pig tail (1.5 m) (IP65) 23.Pig tail (1.5 m) + PG7 cable gland (IP65, IP67 (3)) 54.Pig tail cable outlet with 1/2 NPT male (1.5 m) (IP65) 20.Terminal strip outlet + screwed cap (IP65, IP67) 09.6 contacts HE302 plug (IP65) 24.M12, 4 contacts plug (IP65) 27.Submersible cable (IP68 version (4))
Model 1´...3´ digitIntrinsically safe Output signal 4´ digit
0...10 Vdc4...20 mA1...5 Vdc0...20 mA
Hydraulic connection 5´...6´ digitG 1/4G 1/2 standard1/4 NPT1/2 NPT Sensor seal 7´ digit
NBR (Nitril) standardCR (Neoprene) (P ≥ 250 mbar)EPDM (P ≥ 250 mbar)Kalrez® (P ≥ 1 bar)FKM (Viton®) Pressure range 8´...10´ digit
See codes in tables Pressure type 11´ digit
AbsoluteGauge
Kalrez® and Viton® are registered trademarks of DuPont Dow Elastomers
Measuring Ranges
Ordering Details - Y910
(1) see specifications for details / (2) IP65 : water spray / (3) IP67 : temporary immersion /(4) IP68 : prolonged immersion
Y91x xx x xxx x
Y91 2 3 4 6
02 03 05 06
3 4 5 7 9
xxx
A R
Pressure in mbar Pressure in bar
compound pressure — — — — — — — — -1+0 -1+0.6 -1+1.5 -1+3 -1+5 -1+9 -1+15 -1+24 -1+39 — — — — — —
pressure 25 40 60 100 160 250 400 600 1 1.6 2,5 4 6 10 16 25 40 60 100 160 250 400 600
Measurement range 27.5 44 66 110 175 275 440 660 1.1 1.75 2.75 4.4 6.6 11 17.6 27.5 44 66 110 176 275 440 660
Max. over pressure 110 110 275 500 500 1000 1000 1000 3 3 4 8 12 20 32 50 80 120 200 320 500 600 800
Burst pressure 200 200 500 1000 1000 2000 2000 2000 6 6 7 12 18 30 48 75 120 180 300 480 600 800 1000
Range in mbar 0 + 25 – R 0 + 40 – R 0 + 60 – R 0 + 100 – R 0 + 160 – R 0 + 250 A R 0 + 400 A R 0 + 600 A R
code Range in bar. Vacuum pressure
-1 + 0 – R -1 + 0.6 – R -1 + 1.5 – R -1 + 3 – R -1 + 5 – R -1 + 9 – R -1 + 15 – R -1 + 24 – R -1 + 39 – R 0 + 1 A R 0 + 1.6 A R 0 + 2.5 A R 0 + 4 A R 0 + 6 A R 0 + 10 A R 0 + 16 A R 0 + 25 A R 0 + 40 A R 0 + 60 A R 0 + 100 A R 0 + 160 A R 0 + 250 A R 0 + 400 A R 0 + 600 A R
code
B59B72B74B76B77B79B81B82B1LB15B16B18B19B20B22B24B26B27B29B31B33B35B38B39
UK/
09-2
002
Thi
s da
ta s
heet
may
onl
y be
repr
oduc
ed in
full.
N05N06N07N08N09N10N11N12