NFPA 13 – Chapter 21
Alternative Sprinkler System Designs
for Chapters 12 -20
1
http://www.google.com/url?sa=i&rct=j&q=NFPA+13&source=images&cd=&cad=rja&docid=L5LMmf8bYad8tM&tbnid=1fpJXjxu_stfAM:&ved=0CAUQjRw&url=http://www.brownbookshop.com/products/NFPA-13:-Standard-for-the-Installation-of-Sprinkler-Systems-2013-Edition.html&ei=Ba-LUcKrMuji4APmyoCYCA&bvm=bv.46226182,d.dmg&psig=AFQjCNGdHrVnzx3Z2fCkEn2zRUckLA8g7A&ust=1368195199133546http://www.google.com/url?sa=i&rct=j&q=NFPA+13&source=images&cd=&cad=rja&docid=L5LMmf8bYad8tM&tbnid=1fpJXjxu_stfAM:&ved=0CAUQjRw&url=http://www.brownbookshop.com/products/NFPA-13:-Standard-for-the-Installation-of-Sprinkler-Systems-2013-Edition.html&ei=Ba-LUcKrMuji4APmyoCYCA&bvm=bv.46226182,d.dmg&psig=AFQjCNGdHrVnzx3Z2fCkEn2zRUckLA8g7A&ust=1368195199133546http://www.google.com/url?sa=i&rct=j&q=NFPA+13&source=images&cd=&cad=rja&docid=L5LMmf8bYad8tM&tbnid=1fpJXjxu_stfAM:&ved=0CAUQjRw&url=http://www.brownbookshop.com/products/NFPA-13:-Standard-for-the-Installation-of-Sprinkler-Systems-2013-Edition.html&ei=Ba-LUcKrMuji4APmyoCYCA&bvm=bv.46226182,d.dmg&psig=AFQjCNGdHrVnzx3Z2fCkEn2zRUckLA8g7A&ust=1368195199133546
8/17/2019 Sprinkler Design Presentation
2/25
Why Chapter 21??
• Add a New Chapter
•
Performance-Based Discharge Criteria
2
8/17/2019 Sprinkler Design Presentation
3/25
Chapter 21
• General
• Palletized, Solid-Piled, Bin Box, Shelf or
Back-to-Back Shelf Storage of Class I-IV and
Plastic Commodities
• Open-Frame Rack Storage of Class I-IV and
Plastic Commodities
• Hose Stream Allowance and Water Supply
Duration
• Minimum Obstruction Criteria
3
8/17/2019 Sprinkler Design Presentation
4/25
Baseline
• Three Categories of Sprinklers
– Control Mode Density/Area (CMDA)
– Control Mode Specific Application (CMSA)
– Early Suppression Fast Response (ESFR)
• Minimum Hydraulic Design Criteria
– Density/Area
–ESFR
• Hose Stream Demand
4
8/17/2019 Sprinkler Design Presentation
5/25
The Challenge
• General Rules of Chapters 12-20
• Storage Variables
–
Arrangement – Commodity Classification
– Commodity Mixtures
– Configurations
5
8/17/2019 Sprinkler Design Presentation
6/25
Chapter 21
• Method for full-scale fire testing
– Specific Storage Arrangements
– Specific Maximum Ceiling Heights
• Resulting in
– Specific Design Requirements based on performance
– Minimum safety factors
6
8/17/2019 Sprinkler Design Presentation
7/25
Intent
• Guidance for planning research for Technical
Committee review and acceptance.
7
8/17/2019 Sprinkler Design Presentation
8/25
Alternative Approach
• Specific Data
• Specific Storage Arrangement
• Particular Commodity
• More Flexibility in Design
8
8/17/2019 Sprinkler Design Presentation
9/25
General Requirements
• 21.1.1 Sprinklers intended to protect storage
fire risks shall be permitted to be installed
using water supply design criteria that are
different from the design criteria specified for
the sprinklers described in Chapters 12through 20 when specifically listed for such
use within the limitations described in this
chapter.
9
8/17/2019 Sprinkler Design Presentation
10/25
General Requirements
• Chapters 12 through 20 apply unless modified
• In-rack protection requirements of Chapters
12 through 20 apply when storage racks are
equipped with solid shelves and in-rack
sprinklers are required per the applicable
chapter.
10
8/17/2019 Sprinkler Design Presentation
11/25
General Requirements
• Requirements of the applicable chapter apply
when ceiling-only protection options are not
available in this chapter.
• Design criteria cannot be used to permit a
reduction in the water supply requirements
for in-rack sprinkler protection.
11
8/17/2019 Sprinkler Design Presentation
12/25
Large Scale Fire Tests
• Challenging test scenarios
• Range of variables associated with the
intended
• Evaluate the ability of the sprinkler to protect
representative storage fire risks
• Based on the manufacturer’s installation and
design parameter instructions and referenced
in the listing.
12
8/17/2019 Sprinkler Design Presentation
13/25
Typical Considerations
• Highest Commodity Classification
• Storage Arrangement Type• Maximum Storage Height
• Sprinkler Spacing
•
Sprinkler Temperature Rating• Ceiling Height
• Clearance to Ceiling
• Sprinkler Distance Below Ceiling
• Minimum Operating Pressure• Aisle Width
• Ignition Location
13
8/17/2019 Sprinkler Design Presentation
14/25
Installation & Design Parameters
(1) Commodity or commodities to be protected
(2) Storage arrangements allowed
(3) Installation guidelines including obstruction
and ceiling construction limitations
(4) Maximum ceiling and storage heights with
associated minimum operating pressures and
number of sprinklers required to be included in
the hydraulic calculation
(5) Hose stream allowance and duration
14
8/17/2019 Sprinkler Design Presentation
15/25
Number of Sprinklers
• Twelve sprinklers for standard coverage
sprinklers
• Eight sprinklers for extended-coverage
sprinklers based on a spacing of 12ft×12ft
(3.7m×3.7m)
• Six sprinklers for extended-coverage sprinklers
based on a spacing of 14ft×14ft (4.3m×4.3m)
15
8/17/2019 Sprinkler Design Presentation
16/25
Minimum Area of Operation
• Based on the proposed sprinkler spacing,
•
Not be less than 768 ft2
(71m2
).
16
8/17/2019 Sprinkler Design Presentation
17/25
21.2
17
8/17/2019 Sprinkler Design Presentation
18/25
21.2
18
8/17/2019 Sprinkler Design Presentation
19/25
21.3
19
8/17/2019 Sprinkler Design Presentation
20/25
21.3
20
8/17/2019 Sprinkler Design Presentation
21/25
Hose Stream Allowance & Duration
21
Sprinkler Type Sprinkler
Spacing Type
Number of
Sprinklers inDesign Area
Hose Stream Allowance
gpm L/min
Water
SupplyDuration
CMDA & CMSA Standard Up to 12
Over 12 to 15
Over 15 to 25
Over 25
250 950
500 1900
500 1900
500 1900
60
90
120
150
CMDA & CMSA Extended
Coverage
Up to 6
Up to 8 (144ft2)
Over 6 to 8
Over 8 to 12
Over 12
250 950
250 950
500 1900
500 1900
500 1900
60
60
90
120
150
ESFR Standard Up to 12
Over 12 to 15
Over 15 to 25
Over 25
250 950
500 1900
500 1900
500 1900
60
90
120
150
8/17/2019 Sprinkler Design Presentation
22/25
Comparison of Design Requirements
22
Sprinkler Type
Number ofDesign
Sprinklers
Hose Stream Allowance
gpm L/min
WaterSupply
Duration
CMDA 20 or More 500 1900 120 or More
EC/CMDA 11 or More 500 1900 120 or More
CMSA
15 or More
500 1900
90 or More
ESFR 12 250 950 60
Sprinkler Type Number of
Design
Sprinklers
Hose Stream Allowance
gpm L/min
Water
Supply
Duration
CMSA & ESFR 12 250 950 60
EC-CMSA
(3.7m x 3.7m)
8 250 950 60
EC-CMSA
(4.3m x 4.3m)
6 250 950 60
Chapters 12 through 19
Chapter 21
8/17/2019 Sprinkler Design Presentation
23/25
EC-CMSA
• Nominal K-Factor – 25.2 (360)
• Commodity Storage
– Palletized, Solid pile and Open Rack Storage
– Commodities of up to Cartoned, Expanded
Group A Plastics
• Maximum Storage Height
• Coverage Areas
– 12ft x 12ft (3.7m x 3.7m)
– 14ft x 14ft (4.3m x 4.3m)
23
8/17/2019 Sprinkler Design Presentation
24/25
Minimum Obstruction Criteria
• Based on the number of sprinklers included in
the design.
• Correlates to requirements for
CMDA/CMSA/EC/ESFR
• Number of sprinklers in the design area
impacts the obstruction requirements
• Options
24
8/17/2019 Sprinkler Design Presentation
25/25
Thank You!
• National Fire Sprinkler Association
• www.nfsa.org
25