View
230
Download
1
Category
Preview:
Citation preview
Schneider ElectricRenewable Energies Catalog> Solutions > Solar inverters> Solar inverter/chargers> System components
For more information visit our website at: www.schneider-electric.co.inSchneider Electric India Pvt. Ltd. (A 100% subsidiary of Schneider Electric Industries SAS)
Corporate office : 9th Floor, DLF Building No.10, Tower C, DLF Cyber City, Phase II,Gurgaon - 122002, Haryana, Tel: 0124 3940400, Fax: 0124 4222036
Customer Care Centre : Toll-free numbers: 1800 180 1707, 1800 103 0011, General number: 0124 4222040, Email: in-care@in.schneider-electric.com
Make the most of your energy
About Schneider Electric 2-3
Quality Policy 4
String inverters 5
Solar inverters (single-phase)
•XantrexGTSeries 6-7
Central inverters 8
Solar inverters(three-phase)
•XantrexGT30E 9-10• XantrexGT100E 11-12
•XantrexGT250E,GT500E andGT630E 13-14
Off-grid and backup 15
Basicoff-gridsystem 16-17
Solar inverter/chargers
•XantrexTRSeries 18-19
•XantrexXWSeries 20-21
Solar charge controllers
•XantrexXWMPPT60150 22-23
•XantrexXWMPPT80600 24-25
•XantrexC12PWM 26-27
•XantrexCSeries 28-29
Solar solution components and PV protection 30
• XantrexGateway 31-32
•Components 33-34
•Protection 35-36
Glossary of terms 37
Contents
Allproductsshowninthiscatalogmaynotbeexactlyasshown.
2 3
The history of Schneider ElectricSchneiderElectric,foundedin1836,hastransformeditselfintotheglobalspecialistinenergymanagement.Fromitsrootsintheironandsteelindustry,heavymachinery,andshipbuilding,itmovedintoelectricityandautomationmanagement.Inthelate20thcenturytheSchneiderGroupshifteditsfocustotheelectricalindustrybyseparatingfromitsnon-strategicactivitiesandwassolidifiedthroughitsacquisitionsofTelemecaniquein1988,SquareDin1991andMerlinGerinin1992.In1999developmentofinstallation,systemsandcontrolwasbolsteredwiththeacquisitionofLexel,Europe’snumbertwoinelectricaldistribution.InMayofthesameyear,thecompanywasrenamedSchneiderElectrictomoreclearlyemphasizeitsexpertiseintheelectricalfield.
From2000through2009SchneiderElectricenteredintoaphaseoforganicgrowthandbeganpositioningitselfinnewmarketsegments:UPS(uninterruptiblepowersupply),movementcontrol,buildingautomationandsecurityandrenewableenergythroughtheacquisitionsofAPC,Clipsal,TAC,Pelco,XantrexTechnologyandmore.
Asaglobalspecialistinenergymanagementwithoperationsinmorethan100countries,SchneiderElectricoffersintegratedsolutionsacrossmultiplemarketsegments,includingleadershippositionsinenergyandinfrastructure,industrialprocesses,buildingautomation,datacenters/networks,aswellasabroadpresenceinresidentialapplications.Focusedonmakingenergysafe,reliable,efficient,productiveandgreen,thecompany's110,000plusemployeesachievedsalesof19.6billionEurosin2010,throughanactivecommitmenttohelpindividualsandorganizations"Makethemostoftheirenergy™."
>Formoreinformation aboutSchneiderElectric andrenewableenergysolutions,pleasevisit www.schneider-electric.com/renewable-energies
Renewable EnergiesInOctoberof2008,withSchneiderElectric’spurchaseofXantrexTechnology,asignificantmilestonewasreachedinthecompany’sexpansionintotherenewableenergiessector.CombiningXantrex’sknowledgeandexpertiseinrenewableenergiesandSchneiderElectric’sdepthofexperienceinenergymanagementwascriticalforthefuturesuccessoftheorganizationinthisspace.TherenewableenergiesbusinessofSchneiderElectricisfocusedondesigninganddevelopingrenewableenergyproductsandsolutionsandprovidingbest-in-class,globalcustomerserviceandtechnicalsupport.
Make the most of your energy
SchneiderElectricprovidesthefullsolutionfrom thepanelDCoutputtothegridconnection,includingmonitoring&supervision.
> About Schneider Electric
4
> Quality policy
At Schneider Electric’s Renewable Energies Business,
customersatisfaction is everyone's number one priority
•Providingoutstandingsolutions,productsandservices.
•Addressingcustomerissuesprofessionally.
•Ensuringaconsistentexperienceworldwide.
•Complyingwiththerequirements.
•Givingprecedencetocustomersatisfactionoveranyotherpriority.
•Listeningwithhumblenessandactingonourcustomers'feedback.
•Deliveringonourcommitments.
•Communicatingproactivelyandtransparently.
•Ourmanagersleadbyexample.
•Ourpeopleenjoyautonomyanddevelopaccountability.
•Weplan,controlandrelentlesslyimprovewithourbusiness processexcellencetoolsandmethodologies.
•Werecognizeandsharebestpracticesandattitudes.
The ultimate measure of quality is customer satisfaction
Wearecommittedtobringingadifferentiatedandsuperiorexperiencetoourcustomers
Wedevelopanexemplarycustomer-centricculture
Weempowerandtrainourpeopletomakenocompromiseonquality
String inverters
6 7
Xantrex™ GT Series Grid Tie Solar Inverters TheXantrexGTSerieshighperformancePVstringinverteroffershigheffi-ciency,lowerinstalledcost,improvedaestheticsandhighreliability. TheXantrexGTSeriesInverterisahighqualityproductthatoffersthe bestprice/performanceratioonthemarket.
Features•SuperiorPVenergyharvest
•Peakinverterefficiency
•Excellentthermalperformance
• IP54enclosure
• Inverterscanbemountedsidebysidewithzeroclearance
•LCDprovidesinstantaneousinformation–powerlevel,dailyenergy andlifetimeproduction,systemstatus,andinstallercustomizedscreens
> Solar inverters
Xantrex™ GT Series
Device short name GT2.8 SP GT3.8 SP GT5.0 SP
Electrical specificationsInput (DC)
Photovoltaicpower 3.07kW 4.18kW 5.3kW
Inputvoltagerange,MPPT 195to550V 195to550V 240to550V
NumberofMPPT 1 1 1
Max.inputvoltage,opencircuit 600V 600V 600V
Max.inputcurrent 15.7A 21.3A 24A
Max.inputshortcircuitcurrent 24A 24A 24A
Output (AC)
Nominaloutputpower 2.5kW 3.3kW 5.0kW
Outputvoltage 230V,singlephase 230V,singlephase 230V,singlephase
Frequency 50Hz 50Hz 50Hz
Outputcurrent 14.5A 19A 23A
Overcurrentprotection 20A 20A 30A
Powerfactor >0.9 >0.9 >0.9
Harmonicdistortion <3% <3% <3%
Topology Transformer,isolated Transformer,isolated Transformer,isolated
EfficiencyPeak 95.0% 95.3% 96.0%
European 94.0% 94.5% 95.2%
General specificationsPowerconsumption,nighttime <1W <1W <1W
IPdegreeofprotection IP54 IP54 IP54
Productweight 19.5kg(42.99lb) 20.0kg(44.09lb) 22.3kg(49.16lb)
Shippingweight 26kg(57.2lb) 26kg(57.2lb) 28.5kg(62.7lb)
Productdimensions(HxWxD) 59.7x40.3x13.6cm 59.7x40.3x13.6cm 59.7x40.3x13.6cm (23.5x15.87x5.35in) (23.5x15.87x5.35in) (23.5x15.87x5.35in)
Shippingdimensions(HxWxD) 72x57x25cm 71x58x24cm 72x56x25cm (28.3x22.4x9.8in) (28x22.8x9.4in) (28.3x22x9.8in)
Devicemounting Wallmount(mountingbracketincluded)
Ambientairtemperatureforoperation -25ºCto65ºC(-13ºFto149ºF) -25ºCto65ºC(-13ºFto149ºF) -25ºCto65ºC(-13ºFto149ºF)
Partnumber 864-0105 864-0104 864-1029-01
Features and optionsTypeofcooling Convection,fannotrequired
Displaytype LCD,2lines16digits
Communicationinterface IntegratedRS232andtwoXanbus™RJ45communicationports
Regulatory approvalsCEmarkedaccordingtothefollowingEUdirectivesandstandards:
EMCDirective EN61000-3-2,EN61000-3-3,EN61000-6-1,EN61000-6-3
LowVoltageDirective EN50178andEN60529
Otherapprovals RoyalDecreeRD661-2007,RD1663/2000
Specificationssubjecttochangewithoutnotice.
String inverters
109
Schneider Electric Xantrex™ GT30 E Grid Tie Solar Inverter
Thethree-phaseXantrexGT30EGridTieSolarInverterisa30kWhigh-performanceinverterthatmakesutility-interactiveinstallationseasierandmorecosteffective.ItofferssuperiorPVenergyharvest,easyinstallation,highreliabilityandacompact,ultra-lightweightdesign.
Features•Oneofthehighestefficienciesinthe30kWclass
•RapidMPPT
•Lightweightandeasytoinstall
•MultipleinvertersareeasilyparalleledforlargePVpowerplants
•ManufacturedinGermany
> Solar inverters
Central inverters
Xantrex™ GT30 E
Electrical specificationsInput (DC)
Photovoltaicpower 35kW
Inputvoltagerange,MPPT 450to800V
Max.inputvoltage,opencircuit 840V
Max.inputcurrent 77.4A
Output (AC)
Nominaloutputpower 29.9kW
Outputvoltage 400V,threephase
Frequency 50/60Hz
Nominaloutputcurrent 43.2A
Powerfactor >0.99above20%ratedpower
Harmonicdistortion <4%atratedpower
Topology Integralhighfrequencytransformer
EfficiencyMaximum 95.0%incl.transformer
European 94.2%incl.transformer
General specificationsPowerconsumption,nighttime <1W
IPdegreeofprotection IP20
Enclosurematerial Powder-coatedaluminum
Productweight 80kg(176.37lb)
Productdimensions(HxWxD) 71x47.5x34.7cm(27.95x18.70x13.66in)
Devicemounting Preparedforwallmounting
Ambientairtemperatureforoperation 0ºCto50ºC(32ºFto122ºF)
Operatingaltitude Upto1500m(4921ft)withoutde-rating
Relativehumidity 0to95%,non-condensing
Partnumber 1-152632-01
Features and optionsTypeofcooling Temperature-dependentforcedconvectioncooling
Displaytype LCD,4lineswithkeypad
Protectivefunctions ACover/under-voltage,ACover/under-frequency,over-temperature,ACandDCover-current, DCover-voltageandreversepolarityprotection
Groundfaultprotection DCisolationmonitoring
Disconnect ACcontactorintegraltoinverterassembly
Outputrelays Fourrelaycontacts(threeuser-settable)
Communicationinterface RS232/485,optionaltelephonemodemforremotesystemmonitoring
Regulatory approvalsLabeledwithCEmarkandcomplieswithapplicableEuropeanDirectives:
EMCDirective EN61000-6-1,-2,-3,-4,EN61000-3-12
LowVoltageDirective EN50178
TheGT30EcomplieswiththerequirementsofVDEWandtheRoyalDecree,Spain
Specificationsaresubjecttochangewithoutnotice.
1211
Schneider Electric Xantrex™ GT100 E Grid Tie Solar Inverter
TheXantrexGT100EGridTieInverterisbasedonareliableplatformthatisusedingrid-connectphotovoltaicandwindturbineapplicationsinNorthAmericaandEurope.Easytoinstallandoperate,theGT100Eautomatesstartupandshutdown.ItincorporatesadvancedMaximumPowerPointTrackingTechnology(MPPT)tomaximizetheenergyharvestedfromaPVarray.Tominimizepowerlossesduringtheconversionprocess,theinverter’sswitchingtechnologyusesinsulatedgatebi-polartransistors.
Features•DigitalSignalProcessor(DSP)basedcontrolswithself-diagnostics andLCDfordisplayofoperatingstatus
• Invertershutoffanddisconnects
•Over-andunder-voltageandfrequencyprotection,shuttingdown theinverter
•Anti-islandingprotection-preventsback-feedinginverter-generated powertothegridintheeventofautilityoutage
•Userdefinablepowertrackingallowstheusertomatchtheinverter tothearray,aswellastoadjustdelayperiodstocustomizesystem shutdownsequences
•Graphicaluserinterfacesoftwareforrealtimecommunications, monitoring,andcontrol
• Isolateddesignwithintegratedtransformer
•Multipleinverterscanbeparalleledforlargepowerinstallations
Options• Insulationmonitoringsystem
•Remotemonitoringandfaultnotificationviavariouscommunication options
•Warrantyextensionsandservicecontractswithuptimeguarantees
> Solar inverters
Xantrex™ GT100 E
Electrical specificationsInput (DC)
Photovoltaicpower 112kW
Inputvoltagerange,MPPT 300to650V
Max.inputvoltage,opencircuit 650V
Max.inputcurrent 347A
Output (AC)
Nominaloutputpower 100kW
Outputvoltage 400V,threephase
Frequency 50Hz,optional60Hz
Nominaloutputcurrent 144A
Powerfactor >0.99above20%ratedpower
Harmonicdistortion <3%atratedpower
Topology Integralisolationtransformer
EfficiencyPeak 96.6%incl.transformer
European 96.0%incl.transformer
General specificationsPowerconsumption,nighttime 93W
IPdegreeofprotection IP21
Enclosurematerial Steel
Productweight 870kg(1918lb)
Productdimensions(HxWxD) 190.5x120.5x60.6cm(75x47.44x23.86in)
Ambientairtemperatureforoperation -10ºCto45ºC(14ºFto113ºF)
Operatingaltitude Upto2000m(6562ft)withoutde-rating
Relativehumidity 0to95%non-condensing
Partnumber 1-153417-02
Features and optionsTypeofcooling Forcedconvectioncooling
Displaytype Four-line,80-characterVFDwithakeypad
Protectivefunctions ACover/under-voltage,ACover/under-frequency,over-temperature,ACandDCover-current,DCover-voltage
AC/DCdisconnect Integraltoinverterassembly
Communicationinterface Modems(EthernetorWireless)forremotemonitoringandfaultsnotification
Regulatory approvalsTheGT100EiscomplianttoapplicableEuropeandirectivesandCEmarked:
EMCDirective EN61000-6-2,EN61000-6-4
TheGT100EcomplieswiththerequirementsofSpain'sRD1663andRD661
Specificationsaresubjecttochangewithoutnotice.
Central inverters
1413
Schneider Electric Xantrex™ GT250 E, GT500 E, and GT630 E Grid Tie Solar Inverters
TheXantrexGT250E,GT500EandGT630EGridTieSolarInvertersprovideacompetitivepriceandperformanceratio,andfeaturetheinsulatedgatebipolartransistor(IGBT)switchingtechnologytoreachahighefficiencylevelof98.4%.Theseinverterscanhandlethemostdemandinggridinteractivefeatureswhilecontinuingtodelivermaximumactivepower tothegrid.
Features•DigitalSignalProcessor(DSP)basedcontrolswithself-diagnostics
•LCDdisplaywithkeypadfordisplayofoperatingstatusandforaccess ofuser-changeablesettings
•Overandunder-voltageandfrequencyprotection,shuttingdown theinverter
•Userdefinablepowertrackingallowstheusertomatchtheinverter tothearray,aswellastoadjustdelayperiodstocustomizesystem shutdownsequences
•DCandACsurgeprotection
•Graphicaluserinterfacesoftwareforrealtimecommunications, monitoringandcontrol
•ManufacturedinGermany
•Five-yearstandardwarranty
Options•1000VInputforGT500E/GT630E
•Gridinteractivefeaturesincludinglowvoltageridethroughandreactive (VAR)powercontrolfortheGT500EandGT630E
• Insulationmonitoringsystemsandpositiveornegativegroundingkits
•Remotemonitoringandfaultsnotificationviavariouscommunication options
•Warrantyextensionsandservicecontractswithuptimeguarantees
> Solar inverters
Central inverters
Xantrex™ GT250 E, GT500 E, and GT630 E
Device short name GT250 E GT500 E GT630 E
Electrical specifications Input (DC)
Photovoltaicpower 280kW 560kW 705kW
Inputvoltagerange,MPPT 450to800V 450to880V(495to880V 575to880V(reducedcurrent forgridinteractiveoption,reduced above820V) currentabove820V)
Max.inputvoltage,opencircuit 880V 930V(1000Voptional) 930V(1000Voptional)
Max.inputcurrent 555A 1120A 1120A
Output (AC)
Nominaloutputpower 250kW 500kW 630kW
Outputvoltage 315Vthreephase 315Vthreephase 375Vthreephase
Frequency 50Hz,optional60Hz 50Hz,optional60Hz 50Hz,optional60Hz
Nominaloutputcurrent 460A 1040A 1040A
Powerfactor >0.99above20%ratedpower >0.99above20%ratedpower >0.99above20%ratedpower (optional0.93leadingto0.93 (optional0.93leadingto0.93 laggingwithgridinteractivefeature) laggingwithgridinteractivefeature)
Harmonicdistortion <3%atratedpower <3%atratedpower <3%atratedpower
EfficiencyMaximum 97.5% 98.1%(98.3%forgrid 98.4% interactiveoption)
European 96.6% 97.6%(97.9%forgridinteractive 98.2% interactiveoption)
General specifications Powerconsumption,nighttime <100W <100W <100W
IPdegreeofprotection IP20 IP20 IP20
Enclosurematerial Steel Steel Steel
Productweight 1160kg(2557.36lb) 1770kg(3902.18lb) 1770kg(3902.18lb) (without1000Voption) (without1000Voption)
Productdimensions(HxWxD) 211.2x200.6x60.5cm 211.2x240.6x60.5cm 211.2x240.6x60.5cm (83.15x78.98x23.82in) (83.15x94.72x23.82in) (83.15x94.72x23.82in) (without1000Voption) (without1000Voption)
Ambientairtemperatureforoperation -10ºCto45ºC(14ºFto113ºF) -10ºCto45ºC(14ºFto113ºF) -10ºCto45ºC(14ºFto113ºF)
Operatingaltitude Fullpowerupto1500m(4921ft), Fullpowerupto1500m(4921ft), Fullpowerupto1500m(4921ft) withpowerderatingabove1500m withpowerderatingabove1500m withpowerderatingabove1500m
Relativehumidity 0to95%non-condensing 0to95%non-condensing 0to95%non-condensing
Partnumber 820-0029-02-01* 822-5005-00-00* 822-6305-00-00*
Features and options Typeofcooling Temperature-dependentforcedconvectioncooling
Displaytype LCD,4lines20digitswithkeypad
Protectivefunctions ACover/under-voltage,ACover/under-frequency,over-temperature,ACandDCover-current,DCover-voltage
AC/DCdisconnect Integraltoinverterassembly
Combinerboxes Optionalfeature(informationonrequest)
Containersolution Optionalfeature(informationonrequest)
Warranty Five-yearstandard
Regulatory approvals GT250E,GT500EandGT630EareCEmarkedfortheEMCDirective(EN61000-6-2andEN61000-6-4)andLowVoltageDirective(EN50178)
GT500EandGT630Ewithgrid-interactiveoptionscomplywithGerman(EON,BDEW)andFrench(EDF)requirements
GT500EcomplieswithSpain'sRD1663andRD661
GT250E,GT500EandGT630EcomplywiththerequirementsofItaly'sENELDK5940
Specificationsaresubjecttochangewithoutnotice.*Otheroptionsavailableuponrequest.
16 17
Basic off-grid system
Withanoff-gridsystem,youcaneasilyproduceyourownpowerwithouttheexpense andenvironmentalimpactofextendingpowerlines,orrelyingcompletelyonagenerator.
Abasicoff-gridsystemconsistsofarenewableenergysourcewhichgeneratesDCpower,abatterybankthatstorestheDCpower,andaninverter.Ourinverteristheintelligentcenterofarenewablepowersystem,seamlesslyconvertingDCpowerto cleanACelectricityforyourneeds.
Withabackupsystem,grid-connectedhomescanbenefitfromelectricityevenifthere isagridfailure.Aninverter/chargerautomaticallydetectsthefailureandswitchestobackuppowerusingenergystoredinabatterybank.
Off-grid and backup
XW SystemTR Series
Residentialbackup system
XW SystemTR Series Residential
off-grid system
1918
Schneider Electric Xantrex™ TR Series Inverter/Chargers (230 V / 50 Hz)
TheXantrexTRSeriesInverter/Chargerisaneconomicalpowerconversionsolutionavailableinawiderangeofmodifiedsine-waveoutputvoltagesandpowerlevels.TheXantrexTRisanexcellentchoiceforoff-gridapplications,ortodeliverdependablebackuppowertoessentialcircuitsinahomeorbusinessduringapoweroutage.
Features•1500VAand2400VAmodels
•230V/50Hzmodels
•12Vdcand24Vdcmodels
•Newdigitaldisplayshowskilowatts(kW)wheninvertingandamps(A) whencharging,plusincorporatesarobustON/OFFmembraneswitch andstatusindicators
•Newpowerfactorcorrected(PFC)charging,combinedwithamore sophisticatedmulti-stagebatterychargingalgorithm,reducescurrent drawandgeneratorrun-time
•Simplifiedcontrolswithasnap-oncoverthatprotectssettingsfrombeing accidentallychanged
• Improvedthermalperformanceallowsfulloutputpowerto50°Cwithout de-rating
•Highsurgecapacitystartsdifficultloadsandhandlesoverloadconditions
•Circuitboardsareconformally-coatedtoprotectthemfromcorrosion forlongerlifeandimprovedreliability
•Durablepowdercoated,corrosionresistantsteelchassis
•Two-yearstandardwarranty
Components•TR-RemoteOn/OffSwitch–includesLEDstatusindicator
•TR-ConduitBox–connectstotheDCsideoftheinverterandaccepts 2cm,2.5cmor5cmconduit
> Solar inverter / chargers
Off-grid and backup
Xantrex™ TR Series (230 V / 50 Hz)
Device short name TR1512 230 50 TR1524 230 50 TR2424 230 50
Electrical specificationsContinuousoutputpower 1.5kVA 1.5kVA 2.4kVA
Outputvoltage 230V 230V 230V
Frequency 50Hz 50Hz 50Hz
Outputcurrent 6.4A 6.4A 10.4A
Surgecapabilitymax.output&duration: Overload10secrating 3000VA 3000VA 4800VA Shortcircuit10secrating 26.5±2.5Apk 26.5±2.5Apk 42±4Apk
Adjustableloadsensingrange 10Wminimumto480Wmaximum 10Wminimumto480Wmaximum 10Wminimumto480Wmaximum
Typeofsignal(invertmode) Modifiedsinewave Modifiedsinewave Modifiedsinewave
DCinputcurrentatnoload 0.35A 0.20A 0.20A (searchmode)
DCinputvoltagelimits 11to15V 22to30V 22to30V
RatedDCinputcurrent 158A 77A 121A
Loadpowerfactor(allowed) 0.8to1.0(leadingorlagging) 0.8to1.0(leadingorlagging) 0.8to1.0(leadingorlagging)
Seriesoperation No No No
ACinputvoltagelimits 120to253V(wide), 120to253V(wide) 120to253V(wide) (bypass/chargemode) 180to253V(narrow), 180to253V(narrow) 180to253V(narrow)
Inputfrequency 45to55Hz(narrow-charge&pass-through) 45to68Hz(wide-charge) 41to68Hz(widepass-through)
Built-Ininternal 15Abypass, 15Abypass, 15Abypass, supplementalbreakers 8Acharger 8Acharger 15Acharger
Chargingcurrent(adjustable) 10to70A 5to35A 10to70A
ACinputcurrentatmax.chargerate 5.9A 6.0A 10.4A
Chargerpowerfactor 0.91 0.83 0.92
Multi-stagecharging Yes–bulk,absorptionandfloat,plususer-initiatedequalize(forfloodedbatteriesonly)
Temperaturecompensation Batterytemperaturesensorincluded Batterytemperaturesensorincluded Batterytemperaturesensorincluded
Automatictransferrelay 15A 15A 15A
Transfertime(typical) <40ms(wide),<20ms(narrow) <40ms(wide),<20ms(narrow) <40ms(wide),<20ms(narrow)
EfficiencyPeak >92% >91% >94%
General specificationsProductweight 19kg(42lb) 19kg(42lb) 19kg(42lb)
Shippingweight 23.6kg(52lb) 23.6kg(52lb) 23.6kg(52lb)
Productdimensions(HxWxD) 18.4x21.6x54.6cm 18.4x21.6x54.6cm 18.4x21.6x54.6cm (7.2x8.5x21.5in) (7.2x8.5x21.5in) (7.2x8.5x21.5in)
Shippingdimensions(HxWxD) 30x31.5x67.5cm 30x31.5x67.5cm 30x31.5x67.5cm (11.8x12.4x26.6in) (11.8x12.4x26.6in) (11.8x12.4x26.6in)
Devicemounting Wallmount(with16inmountingcenters) Wallmount(with16inmountingcenters) Wallmount(with16inmountingcenters)
Ambientairtemperatureforoperation 0°Cto50°C 0°Cto50°C 0°Cto50°C (32°Fto122°F) (32°Fto122°F) (32°Fto122°F)
Warranty Two-yearstandard Two-yearstandard Two-yearstandard
Partnumber 989-1025 989-1030 989-1035
Optional componentsXantrexTRConduitBox(989-1050) ConnectstotheDCsideoftheinverterandaccepts3/4,1or2inchesconduit
XantrexTRRemoteOn/OffSwitch(989-1060) IncludesLEDstatusindicator
Regulatory approvalsCEMarkedandcompliantwithEurope'sEMCDirective(EN61000-6-1,-6-3,-3-2,and-3-3)andLowVoltageDirective(EN50178)
Specificationsaresubjecttochangewithoutnotice.
2120
Schneider Electric Xantrex™ XW Inverter/Charger TheSchneiderElectricXantrexXWinverter/chargerfeaturessine-wavepower andadvancedbatterychargingtechnology.Theproductlineoffersinverter/chargersinpowerlevelsfrom4kWto6kWinanexpandableconfigurationallowingfor futuresystemgrowthineithersingleorthree-phaseapplicationsupto36kW. Theproductscanbeusedineitheragrid-tiedwithbatterybackuporoff-gridappli-cationtosuitawidevarietyofinstallations.
Features•Truesine-waveoutput
•230V/50HzModels
•24Vmodelsratedat4000VAand48Vmodelsratedat4500VAor6000VA
•Highsurgecapacity–Full200%ratedoutputpowerisdeliveredtoloads
•Allmodelssuitableforoff-gridorhybrid/backuppowerapplications
•Single-phase(230V/50Hz)andthree-phase(230/400V/50Hz)configurations possible
•Uptofourinverterscanbeinstalledinparalleltocreatelargersingle-phase systemsupto24kVA
•Uptotwoinvertersperphasecanbeconnectedforthree-phaseinstallations upto36kVA
•DualACinputs(gridandgenerator)withautomatictransfer;externaltransfer switchnotrequired
•Efficient,powerfactorcorrected,high-current,multistagebatterycharging
•Configurableauxiliaryoutput
•Nonvolatilememorystoresparametersettings
•Fullcontrolofgeneratorwithoptionalautomaticgeneratorstart(AGS)
•CEmarked
•Mountingbracketincluded
•LocalLEDdisplayoninvertershowsoutputpower,chargecurrentandbattery level,toprovidesystemstatusat-a-glance
•Xanbus™Networkprovidesplug-and-playnetworking
> Solar inverter / chargers
Off-grid and backup
Xantrex™ XW Series (230 V / 50 Hz)
Device short name XW6048 230 50 XW4548 230 50 XW4024 230 50
Electrical specificationsContinuouspower 6.0kVA 4.5kVA 4.0kVA
Surgerating 12.0kVA(15sec) 9.0kVA(20sec) 8.0kVA(20sec)
Outputcurrent 26.1A 19.6A 17.4A
Peakoutputcurrent 53A 40A 35A
Inputcurrentatratedpower 131A 96A 178A
Typeofsignal Truesinewave Truesinewave Truesinewave
Automatictransferrelay 56A 56A 56A
Typicaltransfertime 8ms 8ms 8ms
DCinputvoltage(nominal) 50.4V 50.4V 25.2V
Inputvoltagelimits 44to64V 44to64V 22to32V
Chargingcurrent 100A 85A 150A
Powerfactorcorrectedcharging 0.98 0.98 0.98
Auxiliaryrelayoutput 0to12V,maximum250mADC 0to12V,maximum250mADC 0to12V,maximum250mADC
Powerconsumption(searchmode) <7W <7W <7W
ACinputvoltage(nominal) 230V+/-3% 230V+/-3% 230V+/-3%
Inputvoltagelimits(bypass/chargemode) 165to280V(230Vnominal) 165to280V(230Vnominal) 165to280V(230Vnominal)
Frequency 50Hz+/-0.1Hz 50Hz+/-0.1Hz 50Hz+/-0.1Hz
ACinputfrequencyrange(bypass/chargemode) 40to68Hz(50Hznominal) 40to68Hz(50Hznominal) 40to68Hz(50Hznominal)
Totalharmonicdistortion(THD) <5%atratedpower <5%atratedpower <5%atratedpower
ACconnections AC1(Grid),AC2(Generator) AC1(Grid),AC2(Generator) AC1(Grid),AC2(Generator)
ACinputbreaker 60Asingle-pole 60Asingle-pole 60Asingle-pole
Utilityinteractive Disabled Disabled Disabled
EfficiencyPeak 95.4% 95.6% 94.0%
General specificationsIPdegreeofprotection IP20(sensitiveelectriccomponentssealedinsideenclosure)
Productweight 55.2kg(121.7lb) 53.5kg(118lb) 52.5kg(116lb)
Shippingweight 76.7kg(169lb) 75kg(165lb) 74kg(163lb)
Productdimensions(HxWxD) 58x41x23cm(23x16x9in) 58x41x23cm(23x16x9in) 58x41x23cm(23x16x9in)
Shippingdimensions(HxWxD) 71.1x57.2x39.4cm 71.1x57.2x39.4cm 71.1x57.2x39.4cm (27.99x22.52x15.51in) (27.99x22.52x15.51in) (27.99x22.52x15.51in)
Devicemounting Wallmount(backplateincluded) Wallmount(backplateincluded) Wallmount(backplateincluded)
Ambientairtemperatureforoperation -25°Cto70°C(-13°Fto158°F)(powerderatedabove45°C(113°F))
Communicationnetworktype Xanbus™ Xanbus™ Xanbus™
Partnumber 865-1035 865-1040 865-1045
Features and options Displaytype StatusLEDsindicateACInstatus,faults/warnings,equalizemode,On/Offandequalizebuttonbatterylevel.
Three-characterdisplayindicatesoutputpowerorchargecurrent
Supportedbatterytypes Flooded(default),Gel,AGM,custom Flooded(default),Gel,AGM,custom Flooded(default),Gel,AGM,custom
Batterybanksize 100to2000Ah(scaledtoPVarraysize)
Batterytemperaturesensor Included Included Included
Nonvolatilememory Yes Yes Yes
Multipleunitconfigurations Single-phase:uptofourparallelunits.Three-phase:twounitsperphase
Optional components (seepage72formoredetails)XantrexXWRemotedisplay(865-1050) XWSCPmonitorsandconfiguresalldevicesconnectedtoXanbusNetwork
XantrexXWGeneratorsupport(865-1060) XWAGSmoduleconnectstoXanbusNetwork.Automaticallyactivatesgenerator torechargedepletedbatterybank orassistinverterwithheavyloads
XantrexXWConduitBox(865-1025) XWCBenclosesthebottomoftheinverterandprotectsthecabling.Providesknockoutsfor2cm,2.5cm,3.2cm, 6cm,and6.5cmconduit
XantrexXWMPPT60150(865-1030-1)(page60) XWMPPTSolarChargeControllerwithMPPTdeliversthemaximumenergyavailablefromthePVarray XantrexXWMPPT80600(865-1032)(page62) tothebatterybank
XantrexXWConfigurationTool(865-1155) XantrexXWConfigurationToolaidsdealersandinstallersbysimplifyingandexpeditingtheconfiguration and/ortroubleshootingofaXantrexXWSystem
Regulatory approvalCEmarkedaccordingtothefollowingEUdirectivesandstandards:
EMCDirective EN61000-6-1,EN61000-6-3,EN61000-3-2,EN61000-3-3
LowVoltageDirective EN50178
Specificationsaresubjecttochangewithoutnotice.
2322
Schneider Electric Xantrex™ XW MPPT 60 150 Solar Charge Controller
TheXantrexXWMPPT60150isaphotovoltaic(PV)chargecontroller thattracksthemaximumpowerpointofaPVarraytodeliverthe maximumavailablecurrentforchargingbatteries.Whencharging, theXantrexXWMPPT60150regulatesbatteryvoltageandoutput currentbasedontheamountofenergyavailablefromthePVarray andstate-of-chargeofthebattery.
Features •Canbeusedwith12,24,36,48,and60Vbatterysystemsandis abletochargealowernominalvoltagebatteryfromahighernominal voltagearray
•MaximumPowerPointTracking(MPPT)algorithmcontinuallyseeks themaximumpoweravailablefromthePVarray
• IntegratedPVgroundfaultprotectionfornegativegroundedarrays
•Convection-cooleddesigndoesnotrequireacoolingfan−large, aluminum,die-castheat-sinkallowsfulloutputcurrentupto45°C withoutthermalderating
•Selectabletwoorthree-stagechargingalgorithmswithmanual equalizationtomaximizesystemperformanceandimprovebatterylife
•Configurableauxiliaryoutput
•2lines16digitLCDandfourbuttons forconfigurationandsystemmonitoring
• Inputover-voltageandunder-voltageprotection,outputover-current protection,andbackfeed(reversecurrent)protection(warningandfault messagesappearonLCDwhenunitshutsdownasaprotectivemeasure)
•Canalsobeusedwithotherbattery-basedsolarenergysystems
•Over-temperatureprotectionandpowerderatingwhenoutputpower andambienttemperaturearehigh
•BatteryTemperatureSensor(BTS)included−automaticallyprovides temperaturecompensatedbatterycharging
•Xanbus™-enablednetworkcommunicationsprotocol
•Five-yearstandardwarranty
> Solar charge controllers
Off-grid and backup
Xantrex™ XW MPPT 60 150
Device short name XW MPPT 60 150
Electrical specificationsNominalbatteryvoltage 12,24,36,48,60V
Max.PVarrayvoltage(operating) 140V
Max.PVarrayopencircuitvoltage 150Vincludingtemperaturecorrectionfactor
Max.arrayshort-circuitcurrent 60A(48A@STC)
Max.chargecurrent 60A
Max.andmin.wiresizeinconduit #6AWGto#14AWG(10to2.5mm²)
Chargerregulationmethod Three-stage(bulk,absorption,float)plusmanualequalization Two-stage(bulk,absorption)plusmanualequalization
General specificationsPowerconsumption,nighttime 2.5W
Enclosurematerial Indoor,ventilated,sheetmetalchassiswith2.2cmand2.8cm(7/8inand1in)knockoutsandaluminiumheat-sink
Productweight 4.8kg(10.75lb)
Shippingweight 8kg(17.6lb)
Productdimensions(HxWxD) 36.8x14.6x13.8cm(14.5×5.75×5.5in)
Shippingdimensions(HxWxD) 48.3x22.9x35cm(19×9×9.75in)
Devicemounting Verticalwallmount
Ambientairtemperatureforoperation(fullpower) -20°Cto45°C(-4°Fto113°F)
Storagetemperaturerange -40°Cto85°C(-40°Fto185°F)
Operatingaltitude Sealevelto2000m(6562ft)
Warranty Five-yearstandard
Partnumber 865-1030-1
Features and optionsDisplaytype LCD,2lines16digits
Regulatory approvalsSafety CSACertified(UL1741rev.2005,CSA107.1)andCEMarkedfortheLowVoltageDirective(EN50178)
EMC FCCandIndustryCanada(ClassB)andCEMarkedfortheEMCDirective(EN61000-6-1,-6-3)
Specificationsaresubjecttochangewithoutnotice.
2524
Schneider Electric Xantrex™ XW MPPT 80 600 Solar Charge Controller
TheXWMPPT80600isaninnovativesolarchargecontrollerthatoffersanindustry-firstsetoffeatures:highPVinputvoltage(upto600Vdc),MaximumPowerPointTracking(MPPT),and80Achargecurrent.600VdcPVinputvoltagedeliverslowerinstallationcoststhroughfewerPVstrings,longerhomeruns,smallerwiringandconduit,andvirtualeliminationofPVcombinerboxesandcircuitbreakers.MPPTtechnologyhelpsharvestthemostenergyavailablefromthePVarray,regardlessofenvironmentalconditions.80Abatterychargecurrentallowsforconnectionofarrays ratedatupto4800W(48Vbatterybank).
Features •Acceptsarrayvoltagesupto600V,increasinginstallationflexibility andreducinginstallationcost
•MPPTtoimproveenergyharvestoverawiderangeofenvironmental conditions
•80AchargecurrentfromlargePVarrayswithjusttwostrings
•Charges24Vor48Vbatterybanks
•Fulloutputpowerat45ºCwithoutderating(2560Wfor24Vsystems, 4800Wfor48Vsystems)
•Configurableforpositive,negative,andungroundedPVsystems
• IntegratedPVgroundfaultprotection
•ConfigurableAuxiliaryoutput
• Inputover-voltageandunder-voltageprotection,outputovercurrent protection,andbackfeed(reversecurrent)protection
•Over-temperatureprotectionandpowerderatingwhenambient temperaturesarehigh
•BatteryTemperatureSensor(BTS)included–automaticallyprovides temperaturecompensatedbatterycharging
•Xanbus™–enablednetworkcommunicationsprotocolallowssettings andactivitytobecommunicatedtootherXanbus-enableddevices,such astheXWHybridInverter/Charger,theXWSystemControlPanel(SCP), XWAutomaticGeneratorStart(XWAGS)andotherXWSolarCharge Controllers
•Provideson-boardXanbus™networkpowerforuseinstand-alone applicationswithcommunicationsgateway
•Canbeinstalledinastand-alonemodewithXWSystemControlPanel (XWSCP)(soldseparately)
•Five-yearstandardwarranty
> Solar charge controllers
SchneiderElectricXantrexXWSCP
Off-grid and backup
Xantrex™ XW MPPT 80 600
Device short name XW MPPT 80 600
Electrical specificationsNominalbatteryvoltage 24and48V(Defaultis48V)
Max.PVarrayvoltage(operating) 195to550V
Max.PVarrayopencircuitvoltage 600Vincludingtemperaturecorrectionfactor
Arrayshort-circuitcurrent 35A(28A@STC)
Max.chargecurrent 80A
Max.andmin.wiresizeinconduit #6AWGto#14AWG(13.5to2.5mm2)
Chargerregulationmethod: Three-stage(bulk,absorption,float)plusmanualequalization Two-stage(bulk,absorption)plusmanualequalization
General specificationsPowerconsumption,nighttime <1W
Enclosurematerial Indoor,ventilated,aluminumsheetmetalchassiswith22.22mmand27.76mm(7/8inand1in)knockouts andaluminumheatsink
Productweight 13.5kg(29.8lb)
Shippingweight 17.4kg(38.3lb)
Productdimensions(HxWxD) 76×22×22cm(30×8.625×8.625in)
Shippingdimensions(HxWxD) 87×33×27cm(34.3×13×10.6in)
Devicemounting Verticalwallmount
Ambientairtemperatureforoperation -20°Cto65°C(-4°Fto149°F),powerderatingabove45°C
Storagetemperaturerange -40°Cto85°C(-40°Fto185°F)
Operatingaltitude Sealevelto2000m(6562ft)
Warranty Five-yearstandard
Partnumber 865-1032
Regulatory approvalsCertifiedtoUL1741:2ndEdandtoCSA107.1-01
Specificationsaresubjecttochangewithoutnotice.
2726
Schneider Electric Xantrex™ C12 PWM Charge Controller
TheXantrexC12PWMcharge,lighting,orloadcontrollerisuniquelysophisticated.Asachargecontroller,itfeaturesthree-stagecharging, userdefinablevoltageparameters,andautomaticequalization.StandardintheXantrexC12PWM’sloadcontrolcircuitryarefieldadjustablelowvoltagedisconnectandreconnectpoints,alongwithafiveminutelowbatterydisconnectwarning.TheXantrexC12PWMalsofunctionsasalightingcontroller.Lightingruntimeisadjustablefromtwotoeighthours orcanbesetfromdusktodawnoperation.Itisusedworldwideinavarietyofapplications,includingremotevillagelightingsystemsandautomaticoutdoorlighting.Anoptionalbatterytemperaturesensorensuresprecisebatterychargingregardlessofbatterytemperaturefluctuations.
Features•Silent,pulsewidthmodulatedmicroprocessorcontrol(maximizing batterylife)
•Fieldadjustablevoltageandbatterysetpoints
•Electronicprotectionagainstshort-circuit,overload,over-temperature andreversepolarityconditions
•Two-yearstandardwarranty
> Solar charge controllers
Off-grid and backup
Xantrex™ C12 PWM
Device short name C12 PWM
Electrical specificationsRatedPVcurrent 12Aat12Vonly
Max.DCload 12Awithautoreset
Min.operatingvoltage 6V
Max.voltagedrop(PVtobattery) 0.3V
Max.voltagedrop(batterytoDCload) 0.5V
Regulationsetting 13to15V
Equalizesetting Bulkplus1voltfortwohours
Max.strandedwiresize #10AWGstranded(5.2mm2)
Typicalconsumptionwhilecharging 0.007A
Typicalconsumptionwithloaddisconnected 0.003A
General specificationsPowerconsumption,nighttime 0.003A
Enclosurematerial Powdercoatedsteelwithstrainreliefforwiringandknockoutsforupto3.5inconduits
Productweight 0.9kg(1.98lb)
Shippingweight 1.13kg(2.49lb)
Productdimensions(HxWxD) 16.5x11x4cm(6.5x4.33x1.57in)
Shippingdimensions(HxWxD) 20.3x11.7x4cm(7.99x4.61x1.57in)
Devicemounting Verticalwallmount–indooronly
Ambientairtemperatureforoperation 0°Cto40°C(32°Fto104°F)
Warranty Two-yearstandard
Partnumber C12–chargecontroller
Features and optionsRegulationmethod Standard–three-stage(bulk,absorption,andfloat),solidstate,pulsewidthmodulation
Fieldadjustablecontrolsetpoints Standard–removableknobsandcalibratedscales
Settingprotection Standard–knobscanberemovedtopreventtampering
Testpoints Standard–providedforeachsetting
Automaticequalization Standard–every30daysoraftervoltagereacheslowvoltagedisconnect–canbedisabled
Externalbatterytemperaturecompensation Optional–batterytemperaturesensor(BTS)
Shortcircuitprotection Standard–fullyelectronicallyprotectedwithautoresetandmanualresetswitch,protectsboththeloads andPVarrayfromdamagefromshortcircuits–afuseforthebatteryisstilladvisedtoprotect thebatterywiresiflocatedseparately
Reversepolarityprotection Standard–fullyprotected
Lowvoltagedisconnect Standard–adjustableautomaticormanualoperation,manualreconnectionincludeswarningflash ofloadsfiveminutesbeforeandatenminutegraceperiod
Regulatory approvalsCEmarkedfortheLowVoltageDirectiveandEMCDirective
Specificationsaresubjecttochangewithoutnotice.
2928
Schneider Electric Xantrex™ C Series Controller
TheXantrexC35PWMandC60PWMarefieldconfigurablefor 12-and24-Voperation.TheXantrexC40PWMmaybeconfigured for12-,24-,or48-Voperation.Allcanbeusedasacharge,diversion, orloadcontrollerandcomewithastandardmulti-colorchargestatusLED.
Features•Silent,pulsewidthmodulatedmicroprocessorcontrol (helpingtomaximizebatterylife)
•Fieldadjustablevoltageandbatterytypesetpoints
•Electronicprotectionagainstshort-circuit,overload, over-temperature,andreversepolarityconditions
•Two-yearstandardwarranty
C Series•CM:Cumulativeamphourmeter
•CM/R:Remotecumulativeamphourmeter (availablein50or100footlengths)
•BTS:Batterytemperaturesensor
Optional components: CM and CM/R Digital Meter or Remote DisplayThisdigitalmetermountsontothefrontofachargecontrolleroras aremoteitcanbeinstalledupto31maway.Itdisplaysvolts,amps, andresettablecumulativeamphoursforasolararray,DCloads, ordiversionloads,dependingontheapplication.TheCM/Rcomes with15or30.5mcommunicationcableforremoteinstallation.
> Solar charge controllers
Off-grid and backup
Xantrex™ C Series
Device short name C35 PWM C40 PWM C60 PWM
Electrical specificationsRatedPVcurrent 35A 40A 60A
Charging/loadcurrent@25°C(77°F) 35A 40A 60A
Voltageconfigurations 12and24V 12,24,and48V 12and24V
Max.PVopencircuitarrayvoltage 55V 125V 55V
Max.voltagedropthroughcontroller 0.30V 0.30V 0.30V
Totaloperatingconsumption 15mA 15mA 15mA
Recommendedbreakersize 60Aratedat100%continuousduty 60Aratedat100%continuousduty 60Aratedat100%continuousduty
Recommendedwiresize #6AWGratedat90°C(194°F) #6AWGratedat90°C(194°F) #6AWGratedat90°C(194°F)
Leadacidbatterysettings Adjustable Adjustable Adjustable
NiCdbatterysettings Adjustable Adjustable Adjustable
Loadcontrolmode Lowvoltagereconnect–adjustable(stickerprovidedwithunit)allmodels Lowvoltagedisconnect–userselectablemanualorautomaticreconnection– (includeswarningflashbeforedisconnectandprovidesaonetime,userselectedgraceperiod)allmodels
General specificationsPowerconsumption,nighttime 3mA 3mA 3mA
Enclosurematerial Indoor,ventilated,powdercoatedsteel Indoor,ventilated,powdercoatedsteel Indoor,ventilated,powdercoatedsteel with2cmand2.5cmknockouts with2cmand2.5cmknockouts with2cmand2.5cmknockouts
Productweight 1.2kg(2.65lb) 1.4kg(3.09lb) 1.4kg(3.09lb)
Shippingweight 1.4kg(3.09lb) 1.6kg(3.53lb) 1.6kg(3.53lb)
Productdimensions(HxWxD) 20.3x12.7x6.4cm 25.4x12.7x6.35cm 25.4x12.7x6.35cm (7.99x5x2.52in) (10x5x2.5in) (10x5x2.5in)
Shippingdimensions(HxWxD) 31.5x17.8x6.4cm 31.5x17.8x6.4cm 31.5x17.8x6.4cm (12.4x7.01x2.52in) (12.4x7.01x2.52in) (12.4x7.01x2.52in)
Devicemounting Verticalwallmount–indooronly Verticalwallmount–indooronly Verticalwallmount–indooronly
Ambientairtemperatureforoperation 0°Cto40°C(32°Fto104°F) 0°Cto40°C(32°Fto104°F) 0°Cto40°C(32°Fto104°F)
Operatingaltitude 4572m(15000ft) 4572m(15000ft) 4572m(15000ft)
Non-operatingaltitude 15240m(50000ft) 15240m(50000ft) 15240m(50000ft)
Warranty Two-yearstandard Two-yearstandard Two-yearstandard
Partnumber C35,C40,C60–chargecontrollers CM–Frontdisplaypanel CM/R-50,CM/R-100–Remotedisplaypanel BTS–Batterytemperaturesensor
Features and optionsDisplaytype CM,CM/R-50,orCM/R-100–optionalLCD–backlit,alphanumericdisplayshowingbatteryvoltage,DCamperage, cumulativeamphours,andamphourssincelastreset–remoteincludes15or30.5m(49or100ft)cable
Regulationmethod Solidstate,three-stage(bulk,absorption,andfloat),pulsewidthmodulation
Fieldadjustablecontrolsetpoints Twouseradjustablevoltagesetpointsforcontrolofloadsorchargingsources– settingsretainedifbatteryisdisconnected
Equalizationcharge Userselectablemanualorautomaticequalization–every30days
Batterytemperaturesensor BTS–optionalremotebatterytemperaturesensorforincreasedchargingprecision
Regulatory approvalsSafety ULListedtoUL1741andCSA14;CEMarkedfortheLowVoltageDirective
EMC FCCandIndustryCanadaClassB,CEMarkedfortheEMCDirective
Specificationsaresubjecttochangewithoutnotice.
3231
Schneider Electric Xantrex™ Gateway
TheXantrexGatewaybridgesthegapbetweenaXantrexGTorXWSystemandthesystemowner’scomputer,makingitthecentralcomponentfor aresidentialorsmallcommercialremotemonitoringsystem.
TheXantrexGatewaylogsperformancedatadirectlyfromtheXantrexGTorXWSystem,andtransmitsittotheincludedwidget-basedmonitoringsoftwareforasimpleandgraphicallyrichviewofsystemperformance.Morethanadatalogger,theXantrexGatewayoffersawebpagewiththeabilitytoconfigureautomatedemailreportsandfaultstatustotheuser orinstaller.
TheXantrexGatewayincludesbothbuilt-inWi-FiandEthernetconnectivityallowingforflexibleandsimplesetupforwirelessorwiredconnectionto arouterordirecttoaPC.
The Xantrex Gateway logs and transmits performance data including:•Systempowerproduction
• Inverterspecificpowerproduction
•Lifetimeenergyproduction;daily,weekly,monthlyenergyproduction graphs
• Inverterfaultswithdateandtimestamp
Features•Canmonitoranetworkconsistingofupto20singlephaseGT invertersoruptoeightXantrexXWdevices(XantrexXWInverter/ Charger(s),XantrexXWMPPTSolarChargeController(s), XantrexXWSCP,andXantrexXWAGS)
•Wi-Fi/Ethernetmodulewith10/100Base-Tor802.11b/g
•Canbeconfiguredtosendenergyandalarmreportsviaemail
•Graphicalinteractivesolarmonitoringsoftware
•EmbeddedwebpageforconfiguringtheXantrexGatewayandupgrading inverterfirmware
•16megabytesofstorage
Components
Xantrex™ Gateway
Electrical specificationsCommunication Physicallayer2,CAN
Communicationprotocol Xanbus™
Max.Xanbuscablelength 40m(131ft)
Max.Ethernetcablelength 60m(197ft)
Connectors 3RJ45–8pins(twoXanbus,oneEthernet)
Communication specificationsEthernet IEEEStd802.3-2005™
Wireless 802.11.4band802.11.4g;WEPandWPAsecurity Channels1-11(US/Canada),1-9(Europe)
General specificationsProductweight 0.21kg(0.46lb)
Productdimensions(HxWxD) 11.2x19.0x45cm(4.41x7.48x17.72in)
Heightincludingantenna 24.9cm(9.8in)
Partnumber 865-1056
Regulatory approvals NorthAmerica EMCFCCandIndustryCanadaclassB
Europe Safety LowVoltageDirectiveEN60950-1 EMC EMCDirectiveEN55022,EN55024 Telecom R&TTEDirective,ETSIEN301489-1,ETSIEN301489-17
Specificationsaresubjecttochangewithoutnotice.
3433
Schneider Electric XantrexTM XW System componentsSchneider Electric Xantrex™ XW SCP*
(865-1050)
TheXantrexXWSystemControlPanelfeaturesagraphical,backlitLCDdisplaythatprovidessystemconfiguration anddiagnosticinformationfordevicesconnectedtotheXanbus™-enablednetwork.TheXWSCPgivesasingle pointofcontroltosetupandmonitoranentiresystem,whichmayconsistofmultipleXantrexXWInverter/Chargers,XantrexXWMPPTSolarChargeControllersandothercomponents.
Schneider Electric Xantrex™ XW AGS*
(865-1060)
TheXantrexXWAutomaticGeneratorStartwillautomaticallyactivateageneratortoprovideanXantrex XWInverter/Chargerwithpowertorechargeadepletedbatterybankorprovideadditionalpowerforheavyloads. TheXWAGSaddsintelligencetogeneratormanagement,therebyeliminatingtimespentmonitoringbatteriesandinverterloads.
Schneider Electric Xantrex™ XW CB(865-1025)
TheXantrexXWConduitBox,isabareconduitbox(nowires)thatcanbeusedtocreatesystemslargerthan twoinverters,ortoretrofitXantrexXWInvertersintoexistingsystemswhichmayalreadyhaveAC/DCdisconnects.
Schneider Electric Xantrex™ XW CK(865-1020)
TheXantrexXWConnectionKitisawiringkitandconduitboxusedtoconnectasecondinvertertoaXantrexXW PowerDistributionPanel.Allwiresaremeasured,pre-cutandlabeledtofacilitatequickandeasyinstallation.
Schneider Electric Xantrex™ XW PDP(865-1015)
TheXantrexXWPowerDistributionPanelwhichcomeswithaconduitboxisfactory-wiredandlabeledtosupportacode-compliantsingle-inverterinstallation.InternalwiringandbreakerscanbeaddedtoexpandtheXWSystemwithuptothreeinverters,fourchargecontrollers,orotherequipmenttosupportlargersystems.
Schneider Electric Xantrex™ XW CT(865-1155)
TheXantrexXWConfigurationToolisaPC-basedtool(applicationandnetworkadapter)thatprovidesforversatileXWsystemanalysis,configuration,andrecordingofsystem-andindividualcomponent(XWInverter/Charger,XWChargeController,XWAGS)settings.Toolwizardsenhancetheconfigurationprocess,theXantrexXWCTcanbeusedtoupdatecomponentfirmware–rightinthefield!
* Meets regulatory approvals: CSACertified(UL458andCSA107.1) EMCDirective:FCCandIndustryCanadaClassB,andCEmarkedfortheEMCDirective(EN61000-6-1,-6-3).
Components
Photovoltaic installations componentsSchneider Electric Solar Disconnect Switch(REHU393IP(3Poles,100Amps),REHU493IP(4Poles,100Amps),REHU394IP(3Poles,200Amps),REHU494IP(4Poles,200Amps))
The1000VDCdisconnectswitchfunctionsasalocaldisconnectforastringofPVpanelsandisIEC60947compliantforuseinPhotovoltaicSystemsatamaximumof1000VDC.Thiscompactdisconnectisavailableinboth100and200amp,three-poleandfour-poleversions.
Single or multi-inverter PV system componentsSchneider Electric Xantrex™ GT SIM*
(864-0203)
TheXantrexGridTieSolarInverterMonitorfeaturesagraphical,backlitLCDscreentomonitoryoursingleormulti-inverterPVsysteminoneconvenientlocationinsidethehome.TheXantrexGTSIMisasimplemeansofmonitoring yoursolarsystem,withitslargekeypadbuttons,anintuitiveon-screenmenusystem,andplaintextstatusmessages tomakethemonitoreasytoreadanduse.ThemonitoreasilyconnectstoXantrexGTSeriesinvertersusingstandard CAT5Ethernetcablethatalsoprovidespowertothemonitor.Built-inflashmemorystoresPVsystemdataandmakessoftwareupgradessimple.
XantrexTM C Series Charge Controller componentsSchneider Electric Xantrex™ BTS(130-0004)
TheXantrexBatteryTemperatureSensormountsonyourbatteryandmeasuresitstemperature.ItsendspreciseinformationtoanInverter/ChargerorChargeController,whichautomaticallyadjustschargingvoltagetoensure fullbatterycharge,regardlessoftheambienttemperatureofyourbatteryinstallation.
* Meets regulatory approvals: CSACertified(UL458andCSA107.1) EMCDirective:FCCandIndustryCanadaClassB,andCEmarkedfortheEMCDirective(EN61000-6-1,-6-3).
3635
DC circuit protectors for Photovoltaic installationsSchneider Electric C60PV-DCTheC60PV-DCisaDCcircuitbreakerdedicatedtomultistringforPVinstallationswithVocuntil650V. ItisolatesPVstringsandprotectsthemfromreversecurrent.TheC60PV-DCisnotpolaritysensitive. •Threeratings:10,16,and20A
Schneider Electric Compact NS DC circuit breakerTheCompactNSDCisaDCcircuitbreakerdedicatedtomulti-arrayphotovoltaicinstallationwithVocuntil750V (pleaseconsultforhighervoltage).ItisolatesPVsub-arraysandprotectsthemfromreversecurrent. •Ratingsfrom80Ato250A(fourpoles)
Schneider Electric Masterpact NW DC
TheMasterpactNWDCistheworldwidebenchmarkforhigh-currentcircuit-breakers.TheMasterpactNWcircuit-breakerrangefeaturesoptimiseddimensions.Thisunitmeetsrequirementsfrom4000to6300A.Atatimewheninstallationsarebecomingincreasinglycomplex,MasterpactNWenablesstandardisationofelectricalswitchboardsbyprovidingunrivalledsimplicityintermsofbothchoiceandinstallation.
Schneider Electric NSX DC PV
TheCompactNSXisthenext-generationcircuitbreaker.Apowermonitoringunitenhancesitsprotectivefunctions. Forthefirsttime,userscanmonitorbothenergyandpower,offeringnewperformanceinaremarkablycompactdevice.
DC main switch for photovoltaic installationsSchneider Electric C60NA-DCTheC60NA-DCisanun-polarizedDCswitchdisconnectordedicatedtoarrayisolationandcontrolwithVoc until650V.Whenfusesareprovidedforovercurrentprotection,theuseofC60NA-DCisrequired. •Operatingcurrentandvoltage:20A-650V;30A-500V;40A-400V;50A-300V
Schneider Electric INS PV-1TheINSPV-1isaDCswitchdisconnectordedicatedtoarrayisolationandcontrolwithVocuntil600V. DesignedformaximumperformanceandsafetyforPVapplications,thisproductoperateswithawidechoice ofaccessoriesandauxiliaries. •Operatingcurrentandvoltage:10A-600V;25A-500V;32A-400V
Schneider Electric Compact NS DC switch disconnectorTheCompactNSDCswitchdisconnectorisdesignedforDCVoltageupto750V(pleaseconsultforhighervoltage). ItisdedicatedtoarrayisolationorasamainDCswitch.ForPVinstallationthisproductoperateswithfour-polebasicframesequippedwithaccessories(phasebarrier,poleconnections,rotaryhandleetc.).
Protection
Protection against lightning strikesSchneider Electric PRD-DC surge arrestersThePRD-DCdirectcurrentsurgearresterisdesignedtohelpprotectPVpanelsandtheDCinputtotheinverter fromover-voltagesduetoalightningstrike.Itshouldbeinstalledinanenclosure,weatherproofifinstalledoutside. ThewithdrawablePRD-DCallowsdamagecartridgestobereplacedquickly. •Ratings:40kA,600and1000V •Werecommendthisproducttobeusedwithmini-Kaedraenclosures
Schneider Electric AC surge arresters with built-in disconnectorAlargerangeofACsurgearrestersaredesignedtohelpprotectyourPVinstallationagainstlightninginducedsurges.Eachsurgearresterintherangehasaspecificuse: •Highrisklevel:withmax.40kA(QuickPRD40rsingle-phaseandthree-phase) •Moderaterisklevel:withmax.10,12.5,20kA(PF’clic,QuickPRD20rsingle-phaseandthree-phase)
Schneider Electric TeSys DF PV
Simpleandeffectiveprotection.Fuseprotectionisareliableandeffectivesolutiontoprotectyourlowvoltageequipmentagainstshort-circuitsthatcancausemajordamagetoyourinstallationsandgenerateriskforequipmentandpersonnel,aswellassignificantproductionlosses.
37
Alternating current (AC)Thetypeofelectricitysuppliedbytheutilitycompany. Theuniquecharacteristicofthisformofelectricityisthatitreversesdirectionatregularintervals.Forexample,230V50Hzpowerreversesflow50times asecond,hencetherating50Hz(cycles).
Amp (A)Aunitofmeasureoftheflowofelectricalcurrent.
Amp hour (Ah)Oneampofelectricalcurrentflowingforonehour. TheunitAhisanexpressionofthecapacity(size) ofabattery.
CurrentTherateofflowofelectriccharge,usuallyexpressed inamps(oramperes).
Direct current (DC)Thetypeofelectricitystoredinbatteriesandgeneratedbysolarelectricdevices.Currentflowsinasingledirection.
ElectrolyteAconductivemediuminwhichtheflowofelectricitytakesplace;thisistheliquidfoundinsidestoragebatteries.
GridWhenusedinreferencetoutilitypower,itreferstoasystemofelectricaltransmissionanddistributionlines.
Ground fault protection (GFP)Ashockhazardprotectiondevicethatlimitstheflowofelectricalcurrenttoearth.Usuallyrequiredinwetlocations,e.g.foroutdoor,kitchen,andbathroomcircuits.
Hertz (Hz)
Thefrequency,ornumberoftimespersecond,that theflowofACelectricityreversesitself.Alsoreferred toascycles(seealternatingcurrent).
High battery voltage protectionAcontrolcircuitthatdisconnectschargecurrentflowingtothebatterybeforevoltagereachesadangerouslyhighthreshold.Preventsdamagecreatedbyexcessgassing(orboiling)ofelectrolyte.
Idle currentTheamountofelectricalcurrentrequiredtokeep aninverterreadytoproduceelectricityondemand.
Inrush currentThepeakcurrentanapplianceortoolwilldrawat theinstantitstartsup.
Kilowatt (kW)OnethousandWattsofelectricity.Ten100WattlightbulbsuseonekWofelectricalpower.
Kilowatt hour (kWh)OnekWofelectricalpowerusedforonehour.MostgridconnectedelectricalmetersmeasurekWhforbillingpurposes.
Line lossAvoltagedropcausedbyresistanceinwireduring transmissionofelectricalpoweroverdistance.
LoadAnydevicethatconsumeselectricitytooperate.Appliances,tools,andlightsareexamplesof electricalloads.
Glossary of terms
Recommended