24
Schneider Electric Renewable Energies Catalog > Solutions > Solar inverters > Solar inverter/chargers > System components For more information visit our website at: www.schneider-electric.co.in Schneider Electric India Pvt. Ltd. (A 100% subsidiary of Schneider Electric Industries SAS) Corporate office : 9th Floor, DLF Building No.10, Tower C, DLF Cyber City, Phase II, Gurgaon - 122002, Haryana, Tel: 0124 3940400, Fax: 0124 4222036 Customer Care Centre : Toll-free numbers: 1800 180 1707, 1800 103 0011, General number: 0124 4222040, Email: [email protected] Make the most of your energy

Schneider Electric Renewable Energies Catalog · PDF fileSchneider Electric Renewable Energies Catalog > Solutions > Solar inverters > Solar inverter/chargers > System components For

  • Upload
    trannga

  • View
    230

  • Download
    1

Embed Size (px)

Citation preview

Schneider ElectricRenewable Energies Catalog> Solutions > Solar inverters> Solar inverter/chargers> System components

For more information visit our website at: www.schneider-electric.co.inSchneider Electric India Pvt. Ltd. (A 100% subsidiary of Schneider Electric Industries SAS)

Corporate office : 9th Floor, DLF Building No.10, Tower C, DLF Cyber City, Phase II,Gurgaon - 122002, Haryana, Tel: 0124 3940400, Fax: 0124 4222036

Customer Care Centre : Toll-free numbers: 1800 180 1707, 1800 103 0011, General number: 0124 4222040, Email: [email protected]

Make the most of your energy

About Schneider Electric 2-3

Quality Policy 4

String inverters 5

Solar inverters (single-phase)

•XantrexGTSeries 6-7

Central inverters 8

Solar inverters(three-phase)

•XantrexGT30E 9-10• XantrexGT100E 11-12

•XantrexGT250E,GT500E andGT630E 13-14

Off-grid and backup 15

Basicoff-gridsystem 16-17

Solar inverter/chargers

•XantrexTRSeries 18-19

•XantrexXWSeries 20-21

Solar charge controllers

•XantrexXWMPPT60150 22-23

•XantrexXWMPPT80600 24-25

•XantrexC12PWM 26-27

•XantrexCSeries 28-29

Solar solution components and PV protection 30

• XantrexGateway 31-32

•Components 33-34

•Protection 35-36

Glossary of terms 37

Contents

Allproductsshowninthiscatalogmaynotbeexactlyasshown.

2 3

The history of Schneider ElectricSchneiderElectric,foundedin1836,hastransformeditselfintotheglobalspecialistinenergymanagement.Fromitsrootsintheironandsteelindustry,heavymachinery,andshipbuilding,itmovedintoelectricityandautomationmanagement.Inthelate20thcenturytheSchneiderGroupshifteditsfocustotheelectricalindustrybyseparatingfromitsnon-strategicactivitiesandwassolidifiedthroughitsacquisitionsofTelemecaniquein1988,SquareDin1991andMerlinGerinin1992.In1999developmentofinstallation,systemsandcontrolwasbolsteredwiththeacquisitionofLexel,Europe’snumbertwoinelectricaldistribution.InMayofthesameyear,thecompanywasrenamedSchneiderElectrictomoreclearlyemphasizeitsexpertiseintheelectricalfield.

From2000through2009SchneiderElectricenteredintoaphaseoforganicgrowthandbeganpositioningitselfinnewmarketsegments:UPS(uninterruptiblepowersupply),movementcontrol,buildingautomationandsecurityandrenewableenergythroughtheacquisitionsofAPC,Clipsal,TAC,Pelco,XantrexTechnologyandmore.

Asaglobalspecialistinenergymanagementwithoperationsinmorethan100countries,SchneiderElectricoffersintegratedsolutionsacrossmultiplemarketsegments,includingleadershippositionsinenergyandinfrastructure,industrialprocesses,buildingautomation,datacenters/networks,aswellasabroadpresenceinresidentialapplications.Focusedonmakingenergysafe,reliable,efficient,productiveandgreen,thecompany's110,000plusemployeesachievedsalesof19.6billionEurosin2010,throughanactivecommitmenttohelpindividualsandorganizations"Makethemostoftheirenergy™."

>Formoreinformation aboutSchneiderElectric andrenewableenergysolutions,pleasevisit www.schneider-electric.com/renewable-energies

Renewable EnergiesInOctoberof2008,withSchneiderElectric’spurchaseofXantrexTechnology,asignificantmilestonewasreachedinthecompany’sexpansionintotherenewableenergiessector.CombiningXantrex’sknowledgeandexpertiseinrenewableenergiesandSchneiderElectric’sdepthofexperienceinenergymanagementwascriticalforthefuturesuccessoftheorganizationinthisspace.TherenewableenergiesbusinessofSchneiderElectricisfocusedondesigninganddevelopingrenewableenergyproductsandsolutionsandprovidingbest-in-class,globalcustomerserviceandtechnicalsupport.

Make the most of your energy

SchneiderElectricprovidesthefullsolutionfrom thepanelDCoutputtothegridconnection,includingmonitoring&supervision.

> About Schneider Electric

4

> Quality policy

At Schneider Electric’s Renewable Energies Business,

customersatisfaction is everyone's number one priority

•Providingoutstandingsolutions,productsandservices.

•Addressingcustomerissuesprofessionally.

•Ensuringaconsistentexperienceworldwide.

•Complyingwiththerequirements.

•Givingprecedencetocustomersatisfactionoveranyotherpriority.

•Listeningwithhumblenessandactingonourcustomers'feedback.

•Deliveringonourcommitments.

•Communicatingproactivelyandtransparently.

•Ourmanagersleadbyexample.

•Ourpeopleenjoyautonomyanddevelopaccountability.

•Weplan,controlandrelentlesslyimprovewithourbusiness processexcellencetoolsandmethodologies.

•Werecognizeandsharebestpracticesandattitudes.

The ultimate measure of quality is customer satisfaction

Wearecommittedtobringingadifferentiatedandsuperiorexperiencetoourcustomers

Wedevelopanexemplarycustomer-centricculture

Weempowerandtrainourpeopletomakenocompromiseonquality

String inverters

6 7

Xantrex™ GT Series Grid Tie Solar Inverters TheXantrexGTSerieshighperformancePVstringinverteroffershigheffi-ciency,lowerinstalledcost,improvedaestheticsandhighreliability. TheXantrexGTSeriesInverterisahighqualityproductthatoffersthe bestprice/performanceratioonthemarket.

Features•SuperiorPVenergyharvest

•Peakinverterefficiency

•Excellentthermalperformance

• IP54enclosure

• Inverterscanbemountedsidebysidewithzeroclearance

•LCDprovidesinstantaneousinformation–powerlevel,dailyenergy andlifetimeproduction,systemstatus,andinstallercustomizedscreens

> Solar inverters

Xantrex™ GT Series

Device short name GT2.8 SP GT3.8 SP GT5.0 SP

Electrical specificationsInput (DC)

Photovoltaicpower 3.07kW 4.18kW 5.3kW

Inputvoltagerange,MPPT 195to550V 195to550V 240to550V

NumberofMPPT 1 1 1

Max.inputvoltage,opencircuit 600V 600V 600V

Max.inputcurrent 15.7A 21.3A 24A

Max.inputshortcircuitcurrent 24A 24A 24A

Output (AC)

Nominaloutputpower 2.5kW 3.3kW 5.0kW

Outputvoltage 230V,singlephase 230V,singlephase 230V,singlephase

Frequency 50Hz 50Hz 50Hz

Outputcurrent 14.5A 19A 23A

Overcurrentprotection 20A 20A 30A

Powerfactor >0.9 >0.9 >0.9

Harmonicdistortion <3% <3% <3%

Topology Transformer,isolated Transformer,isolated Transformer,isolated

EfficiencyPeak 95.0% 95.3% 96.0%

European 94.0% 94.5% 95.2%

General specificationsPowerconsumption,nighttime <1W <1W <1W

IPdegreeofprotection IP54 IP54 IP54

Productweight 19.5kg(42.99lb) 20.0kg(44.09lb) 22.3kg(49.16lb)

Shippingweight 26kg(57.2lb) 26kg(57.2lb) 28.5kg(62.7lb)

Productdimensions(HxWxD) 59.7x40.3x13.6cm 59.7x40.3x13.6cm 59.7x40.3x13.6cm (23.5x15.87x5.35in) (23.5x15.87x5.35in) (23.5x15.87x5.35in)

Shippingdimensions(HxWxD) 72x57x25cm 71x58x24cm 72x56x25cm (28.3x22.4x9.8in) (28x22.8x9.4in) (28.3x22x9.8in)

Devicemounting Wallmount(mountingbracketincluded)

Ambientairtemperatureforoperation -25ºCto65ºC(-13ºFto149ºF) -25ºCto65ºC(-13ºFto149ºF) -25ºCto65ºC(-13ºFto149ºF)

Partnumber 864-0105 864-0104 864-1029-01

Features and optionsTypeofcooling Convection,fannotrequired

Displaytype LCD,2lines16digits

Communicationinterface IntegratedRS232andtwoXanbus™RJ45communicationports

Regulatory approvalsCEmarkedaccordingtothefollowingEUdirectivesandstandards:

EMCDirective EN61000-3-2,EN61000-3-3,EN61000-6-1,EN61000-6-3

LowVoltageDirective EN50178andEN60529

Otherapprovals RoyalDecreeRD661-2007,RD1663/2000

Specificationssubjecttochangewithoutnotice.

String inverters

Central inverters

109

Schneider Electric Xantrex™ GT30 E Grid Tie Solar Inverter

Thethree-phaseXantrexGT30EGridTieSolarInverterisa30kWhigh-performanceinverterthatmakesutility-interactiveinstallationseasierandmorecosteffective.ItofferssuperiorPVenergyharvest,easyinstallation,highreliabilityandacompact,ultra-lightweightdesign.

Features•Oneofthehighestefficienciesinthe30kWclass

•RapidMPPT

•Lightweightandeasytoinstall

•MultipleinvertersareeasilyparalleledforlargePVpowerplants

•ManufacturedinGermany

> Solar inverters

Central inverters

Xantrex™ GT30 E

Electrical specificationsInput (DC)

Photovoltaicpower 35kW

Inputvoltagerange,MPPT 450to800V

Max.inputvoltage,opencircuit 840V

Max.inputcurrent 77.4A

Output (AC)

Nominaloutputpower 29.9kW

Outputvoltage 400V,threephase

Frequency 50/60Hz

Nominaloutputcurrent 43.2A

Powerfactor >0.99above20%ratedpower

Harmonicdistortion <4%atratedpower

Topology Integralhighfrequencytransformer

EfficiencyMaximum 95.0%incl.transformer

European 94.2%incl.transformer

General specificationsPowerconsumption,nighttime <1W

IPdegreeofprotection IP20

Enclosurematerial Powder-coatedaluminum

Productweight 80kg(176.37lb)

Productdimensions(HxWxD) 71x47.5x34.7cm(27.95x18.70x13.66in)

Devicemounting Preparedforwallmounting

Ambientairtemperatureforoperation 0ºCto50ºC(32ºFto122ºF)

Operatingaltitude Upto1500m(4921ft)withoutde-rating

Relativehumidity 0to95%,non-condensing

Partnumber 1-152632-01

Features and optionsTypeofcooling Temperature-dependentforcedconvectioncooling

Displaytype LCD,4lineswithkeypad

Protectivefunctions ACover/under-voltage,ACover/under-frequency,over-temperature,ACandDCover-current, DCover-voltageandreversepolarityprotection

Groundfaultprotection DCisolationmonitoring

Disconnect ACcontactorintegraltoinverterassembly

Outputrelays Fourrelaycontacts(threeuser-settable)

Communicationinterface RS232/485,optionaltelephonemodemforremotesystemmonitoring

Regulatory approvalsLabeledwithCEmarkandcomplieswithapplicableEuropeanDirectives:

EMCDirective EN61000-6-1,-2,-3,-4,EN61000-3-12

LowVoltageDirective EN50178

TheGT30EcomplieswiththerequirementsofVDEWandtheRoyalDecree,Spain

Specificationsaresubjecttochangewithoutnotice.

1211

Schneider Electric Xantrex™ GT100 E Grid Tie Solar Inverter

TheXantrexGT100EGridTieInverterisbasedonareliableplatformthatisusedingrid-connectphotovoltaicandwindturbineapplicationsinNorthAmericaandEurope.Easytoinstallandoperate,theGT100Eautomatesstartupandshutdown.ItincorporatesadvancedMaximumPowerPointTrackingTechnology(MPPT)tomaximizetheenergyharvestedfromaPVarray.Tominimizepowerlossesduringtheconversionprocess,theinverter’sswitchingtechnologyusesinsulatedgatebi-polartransistors.

Features•DigitalSignalProcessor(DSP)basedcontrolswithself-diagnostics andLCDfordisplayofoperatingstatus

• Invertershutoffanddisconnects

•Over-andunder-voltageandfrequencyprotection,shuttingdown theinverter

•Anti-islandingprotection-preventsback-feedinginverter-generated powertothegridintheeventofautilityoutage

•Userdefinablepowertrackingallowstheusertomatchtheinverter tothearray,aswellastoadjustdelayperiodstocustomizesystem shutdownsequences

•Graphicaluserinterfacesoftwareforrealtimecommunications, monitoring,andcontrol

• Isolateddesignwithintegratedtransformer

•Multipleinverterscanbeparalleledforlargepowerinstallations

Options• Insulationmonitoringsystem

•Remotemonitoringandfaultnotificationviavariouscommunication options

•Warrantyextensionsandservicecontractswithuptimeguarantees

> Solar inverters

Xantrex™ GT100 E

Electrical specificationsInput (DC)

Photovoltaicpower 112kW

Inputvoltagerange,MPPT 300to650V

Max.inputvoltage,opencircuit 650V

Max.inputcurrent 347A

Output (AC)

Nominaloutputpower 100kW

Outputvoltage 400V,threephase

Frequency 50Hz,optional60Hz

Nominaloutputcurrent 144A

Powerfactor >0.99above20%ratedpower

Harmonicdistortion <3%atratedpower

Topology Integralisolationtransformer

EfficiencyPeak 96.6%incl.transformer

European 96.0%incl.transformer

General specificationsPowerconsumption,nighttime 93W

IPdegreeofprotection IP21

Enclosurematerial Steel

Productweight 870kg(1918lb)

Productdimensions(HxWxD) 190.5x120.5x60.6cm(75x47.44x23.86in)

Ambientairtemperatureforoperation -10ºCto45ºC(14ºFto113ºF)

Operatingaltitude Upto2000m(6562ft)withoutde-rating

Relativehumidity 0to95%non-condensing

Partnumber 1-153417-02

Features and optionsTypeofcooling Forcedconvectioncooling

Displaytype Four-line,80-characterVFDwithakeypad

Protectivefunctions ACover/under-voltage,ACover/under-frequency,over-temperature,ACandDCover-current,DCover-voltage

AC/DCdisconnect Integraltoinverterassembly

Communicationinterface Modems(EthernetorWireless)forremotemonitoringandfaultsnotification

Regulatory approvalsTheGT100EiscomplianttoapplicableEuropeandirectivesandCEmarked:

EMCDirective EN61000-6-2,EN61000-6-4

TheGT100EcomplieswiththerequirementsofSpain'sRD1663andRD661

Specificationsaresubjecttochangewithoutnotice.

Central inverters

1413

Schneider Electric Xantrex™ GT250 E, GT500 E, and GT630 E Grid Tie Solar Inverters

TheXantrexGT250E,GT500EandGT630EGridTieSolarInvertersprovideacompetitivepriceandperformanceratio,andfeaturetheinsulatedgatebipolartransistor(IGBT)switchingtechnologytoreachahighefficiencylevelof98.4%.Theseinverterscanhandlethemostdemandinggridinteractivefeatureswhilecontinuingtodelivermaximumactivepower tothegrid.

Features•DigitalSignalProcessor(DSP)basedcontrolswithself-diagnostics

•LCDdisplaywithkeypadfordisplayofoperatingstatusandforaccess ofuser-changeablesettings

•Overandunder-voltageandfrequencyprotection,shuttingdown theinverter

•Userdefinablepowertrackingallowstheusertomatchtheinverter tothearray,aswellastoadjustdelayperiodstocustomizesystem shutdownsequences

•DCandACsurgeprotection

•Graphicaluserinterfacesoftwareforrealtimecommunications, monitoringandcontrol

•ManufacturedinGermany

•Five-yearstandardwarranty

Options•1000VInputforGT500E/GT630E

•Gridinteractivefeaturesincludinglowvoltageridethroughandreactive (VAR)powercontrolfortheGT500EandGT630E

• Insulationmonitoringsystemsandpositiveornegativegroundingkits

•Remotemonitoringandfaultsnotificationviavariouscommunication options

•Warrantyextensionsandservicecontractswithuptimeguarantees

> Solar inverters

Central inverters

Xantrex™ GT250 E, GT500 E, and GT630 E

Device short name GT250 E GT500 E GT630 E

Electrical specifications Input (DC)

Photovoltaicpower 280kW 560kW 705kW

Inputvoltagerange,MPPT 450to800V 450to880V(495to880V 575to880V(reducedcurrent forgridinteractiveoption,reduced above820V) currentabove820V)

Max.inputvoltage,opencircuit 880V 930V(1000Voptional) 930V(1000Voptional)

Max.inputcurrent 555A 1120A 1120A

Output (AC)

Nominaloutputpower 250kW 500kW 630kW

Outputvoltage 315Vthreephase 315Vthreephase 375Vthreephase

Frequency 50Hz,optional60Hz 50Hz,optional60Hz 50Hz,optional60Hz

Nominaloutputcurrent 460A 1040A 1040A

Powerfactor >0.99above20%ratedpower >0.99above20%ratedpower >0.99above20%ratedpower (optional0.93leadingto0.93 (optional0.93leadingto0.93 laggingwithgridinteractivefeature) laggingwithgridinteractivefeature)

Harmonicdistortion <3%atratedpower <3%atratedpower <3%atratedpower

EfficiencyMaximum 97.5% 98.1%(98.3%forgrid 98.4% interactiveoption)

European 96.6% 97.6%(97.9%forgridinteractive 98.2% interactiveoption)

General specifications Powerconsumption,nighttime <100W <100W <100W

IPdegreeofprotection IP20 IP20 IP20

Enclosurematerial Steel Steel Steel

Productweight 1160kg(2557.36lb) 1770kg(3902.18lb) 1770kg(3902.18lb) (without1000Voption) (without1000Voption)

Productdimensions(HxWxD) 211.2x200.6x60.5cm 211.2x240.6x60.5cm 211.2x240.6x60.5cm (83.15x78.98x23.82in) (83.15x94.72x23.82in) (83.15x94.72x23.82in) (without1000Voption) (without1000Voption)

Ambientairtemperatureforoperation -10ºCto45ºC(14ºFto113ºF) -10ºCto45ºC(14ºFto113ºF) -10ºCto45ºC(14ºFto113ºF)

Operatingaltitude Fullpowerupto1500m(4921ft), Fullpowerupto1500m(4921ft), Fullpowerupto1500m(4921ft) withpowerderatingabove1500m withpowerderatingabove1500m withpowerderatingabove1500m

Relativehumidity 0to95%non-condensing 0to95%non-condensing 0to95%non-condensing

Partnumber 820-0029-02-01* 822-5005-00-00* 822-6305-00-00*

Features and options Typeofcooling Temperature-dependentforcedconvectioncooling

Displaytype LCD,4lines20digitswithkeypad

Protectivefunctions ACover/under-voltage,ACover/under-frequency,over-temperature,ACandDCover-current,DCover-voltage

AC/DCdisconnect Integraltoinverterassembly

Combinerboxes Optionalfeature(informationonrequest)

Containersolution Optionalfeature(informationonrequest)

Warranty Five-yearstandard

Regulatory approvals GT250E,GT500EandGT630EareCEmarkedfortheEMCDirective(EN61000-6-2andEN61000-6-4)andLowVoltageDirective(EN50178)

GT500EandGT630Ewithgrid-interactiveoptionscomplywithGerman(EON,BDEW)andFrench(EDF)requirements

GT500EcomplieswithSpain'sRD1663andRD661

GT250E,GT500EandGT630EcomplywiththerequirementsofItaly'sENELDK5940

Specificationsaresubjecttochangewithoutnotice.*Otheroptionsavailableuponrequest.

17

Off-grid and backup

16 17

Basic off-grid system

Withanoff-gridsystem,youcaneasilyproduceyourownpowerwithouttheexpense andenvironmentalimpactofextendingpowerlines,orrelyingcompletelyonagenerator.

Abasicoff-gridsystemconsistsofarenewableenergysourcewhichgeneratesDCpower,abatterybankthatstorestheDCpower,andaninverter.Ourinverteristheintelligentcenterofarenewablepowersystem,seamlesslyconvertingDCpowerto cleanACelectricityforyourneeds.

Withabackupsystem,grid-connectedhomescanbenefitfromelectricityevenifthere isagridfailure.Aninverter/chargerautomaticallydetectsthefailureandswitchestobackuppowerusingenergystoredinabatterybank.

Off-grid and backup

XW SystemTR Series

Residentialbackup system

XW SystemTR Series Residential

off-grid system

1918

Schneider Electric Xantrex™ TR Series Inverter/Chargers (230 V / 50 Hz)

TheXantrexTRSeriesInverter/Chargerisaneconomicalpowerconversionsolutionavailableinawiderangeofmodifiedsine-waveoutputvoltagesandpowerlevels.TheXantrexTRisanexcellentchoiceforoff-gridapplications,ortodeliverdependablebackuppowertoessentialcircuitsinahomeorbusinessduringapoweroutage.

Features•1500VAand2400VAmodels

•230V/50Hzmodels

•12Vdcand24Vdcmodels

•Newdigitaldisplayshowskilowatts(kW)wheninvertingandamps(A) whencharging,plusincorporatesarobustON/OFFmembraneswitch andstatusindicators

•Newpowerfactorcorrected(PFC)charging,combinedwithamore sophisticatedmulti-stagebatterychargingalgorithm,reducescurrent drawandgeneratorrun-time

•Simplifiedcontrolswithasnap-oncoverthatprotectssettingsfrombeing accidentallychanged

• Improvedthermalperformanceallowsfulloutputpowerto50°Cwithout de-rating

•Highsurgecapacitystartsdifficultloadsandhandlesoverloadconditions

•Circuitboardsareconformally-coatedtoprotectthemfromcorrosion forlongerlifeandimprovedreliability

•Durablepowdercoated,corrosionresistantsteelchassis

•Two-yearstandardwarranty

Components•TR-RemoteOn/OffSwitch–includesLEDstatusindicator

•TR-ConduitBox–connectstotheDCsideoftheinverterandaccepts 2cm,2.5cmor5cmconduit

> Solar inverter / chargers

Off-grid and backup

Xantrex™ TR Series (230 V / 50 Hz)

Device short name TR1512 230 50 TR1524 230 50 TR2424 230 50

Electrical specificationsContinuousoutputpower 1.5kVA 1.5kVA 2.4kVA

Outputvoltage 230V 230V 230V

Frequency 50Hz 50Hz 50Hz

Outputcurrent 6.4A 6.4A 10.4A

Surgecapabilitymax.output&duration: Overload10secrating 3000VA 3000VA 4800VA Shortcircuit10secrating 26.5±2.5Apk 26.5±2.5Apk 42±4Apk

Adjustableloadsensingrange 10Wminimumto480Wmaximum 10Wminimumto480Wmaximum 10Wminimumto480Wmaximum

Typeofsignal(invertmode) Modifiedsinewave Modifiedsinewave Modifiedsinewave

DCinputcurrentatnoload 0.35A 0.20A 0.20A (searchmode)

DCinputvoltagelimits 11to15V 22to30V 22to30V

RatedDCinputcurrent 158A 77A 121A

Loadpowerfactor(allowed) 0.8to1.0(leadingorlagging) 0.8to1.0(leadingorlagging) 0.8to1.0(leadingorlagging)

Seriesoperation No No No

ACinputvoltagelimits 120to253V(wide), 120to253V(wide) 120to253V(wide) (bypass/chargemode) 180to253V(narrow), 180to253V(narrow) 180to253V(narrow)

Inputfrequency 45to55Hz(narrow-charge&pass-through) 45to68Hz(wide-charge) 41to68Hz(widepass-through)

Built-Ininternal 15Abypass, 15Abypass, 15Abypass, supplementalbreakers 8Acharger 8Acharger 15Acharger

Chargingcurrent(adjustable) 10to70A 5to35A 10to70A

ACinputcurrentatmax.chargerate 5.9A 6.0A 10.4A

Chargerpowerfactor 0.91 0.83 0.92

Multi-stagecharging Yes–bulk,absorptionandfloat,plususer-initiatedequalize(forfloodedbatteriesonly)

Temperaturecompensation Batterytemperaturesensorincluded Batterytemperaturesensorincluded Batterytemperaturesensorincluded

Automatictransferrelay 15A 15A 15A

Transfertime(typical) <40ms(wide),<20ms(narrow) <40ms(wide),<20ms(narrow) <40ms(wide),<20ms(narrow)

EfficiencyPeak >92% >91% >94%

General specificationsProductweight 19kg(42lb) 19kg(42lb) 19kg(42lb)

Shippingweight 23.6kg(52lb) 23.6kg(52lb) 23.6kg(52lb)

Productdimensions(HxWxD) 18.4x21.6x54.6cm 18.4x21.6x54.6cm 18.4x21.6x54.6cm (7.2x8.5x21.5in) (7.2x8.5x21.5in) (7.2x8.5x21.5in)

Shippingdimensions(HxWxD) 30x31.5x67.5cm 30x31.5x67.5cm 30x31.5x67.5cm (11.8x12.4x26.6in) (11.8x12.4x26.6in) (11.8x12.4x26.6in)

Devicemounting Wallmount(with16inmountingcenters) Wallmount(with16inmountingcenters) Wallmount(with16inmountingcenters)

Ambientairtemperatureforoperation 0°Cto50°C 0°Cto50°C 0°Cto50°C (32°Fto122°F) (32°Fto122°F) (32°Fto122°F)

Warranty Two-yearstandard Two-yearstandard Two-yearstandard

Partnumber 989-1025 989-1030 989-1035

Optional componentsXantrexTRConduitBox(989-1050) ConnectstotheDCsideoftheinverterandaccepts3/4,1or2inchesconduit

XantrexTRRemoteOn/OffSwitch(989-1060) IncludesLEDstatusindicator

Regulatory approvalsCEMarkedandcompliantwithEurope'sEMCDirective(EN61000-6-1,-6-3,-3-2,and-3-3)andLowVoltageDirective(EN50178)

Specificationsaresubjecttochangewithoutnotice.

2120

Schneider Electric Xantrex™ XW Inverter/Charger TheSchneiderElectricXantrexXWinverter/chargerfeaturessine-wavepower andadvancedbatterychargingtechnology.Theproductlineoffersinverter/chargersinpowerlevelsfrom4kWto6kWinanexpandableconfigurationallowingfor futuresystemgrowthineithersingleorthree-phaseapplicationsupto36kW. Theproductscanbeusedineitheragrid-tiedwithbatterybackuporoff-gridappli-cationtosuitawidevarietyofinstallations.

Features•Truesine-waveoutput

•230V/50HzModels

•24Vmodelsratedat4000VAand48Vmodelsratedat4500VAor6000VA

•Highsurgecapacity–Full200%ratedoutputpowerisdeliveredtoloads

•Allmodelssuitableforoff-gridorhybrid/backuppowerapplications

•Single-phase(230V/50Hz)andthree-phase(230/400V/50Hz)configurations possible

•Uptofourinverterscanbeinstalledinparalleltocreatelargersingle-phase systemsupto24kVA

•Uptotwoinvertersperphasecanbeconnectedforthree-phaseinstallations upto36kVA

•DualACinputs(gridandgenerator)withautomatictransfer;externaltransfer switchnotrequired

•Efficient,powerfactorcorrected,high-current,multistagebatterycharging

•Configurableauxiliaryoutput

•Nonvolatilememorystoresparametersettings

•Fullcontrolofgeneratorwithoptionalautomaticgeneratorstart(AGS)

•CEmarked

•Mountingbracketincluded

•LocalLEDdisplayoninvertershowsoutputpower,chargecurrentandbattery level,toprovidesystemstatusat-a-glance

•Xanbus™Networkprovidesplug-and-playnetworking

> Solar inverter / chargers

Off-grid and backup

Xantrex™ XW Series (230 V / 50 Hz)

Device short name XW6048 230 50 XW4548 230 50 XW4024 230 50

Electrical specificationsContinuouspower 6.0kVA 4.5kVA 4.0kVA

Surgerating 12.0kVA(15sec) 9.0kVA(20sec) 8.0kVA(20sec)

Outputcurrent 26.1A 19.6A 17.4A

Peakoutputcurrent 53A 40A 35A

Inputcurrentatratedpower 131A 96A 178A

Typeofsignal Truesinewave Truesinewave Truesinewave

Automatictransferrelay 56A 56A 56A

Typicaltransfertime 8ms 8ms 8ms

DCinputvoltage(nominal) 50.4V 50.4V 25.2V

Inputvoltagelimits 44to64V 44to64V 22to32V

Chargingcurrent 100A 85A 150A

Powerfactorcorrectedcharging 0.98 0.98 0.98

Auxiliaryrelayoutput 0to12V,maximum250mADC 0to12V,maximum250mADC 0to12V,maximum250mADC

Powerconsumption(searchmode) <7W <7W <7W

ACinputvoltage(nominal) 230V+/-3% 230V+/-3% 230V+/-3%

Inputvoltagelimits(bypass/chargemode) 165to280V(230Vnominal) 165to280V(230Vnominal) 165to280V(230Vnominal)

Frequency 50Hz+/-0.1Hz 50Hz+/-0.1Hz 50Hz+/-0.1Hz

ACinputfrequencyrange(bypass/chargemode) 40to68Hz(50Hznominal) 40to68Hz(50Hznominal) 40to68Hz(50Hznominal)

Totalharmonicdistortion(THD) <5%atratedpower <5%atratedpower <5%atratedpower

ACconnections AC1(Grid),AC2(Generator) AC1(Grid),AC2(Generator) AC1(Grid),AC2(Generator)

ACinputbreaker 60Asingle-pole 60Asingle-pole 60Asingle-pole

Utilityinteractive Disabled Disabled Disabled

EfficiencyPeak 95.4% 95.6% 94.0%

General specificationsIPdegreeofprotection IP20(sensitiveelectriccomponentssealedinsideenclosure)

Productweight 55.2kg(121.7lb) 53.5kg(118lb) 52.5kg(116lb)

Shippingweight 76.7kg(169lb) 75kg(165lb) 74kg(163lb)

Productdimensions(HxWxD) 58x41x23cm(23x16x9in) 58x41x23cm(23x16x9in) 58x41x23cm(23x16x9in)

Shippingdimensions(HxWxD) 71.1x57.2x39.4cm 71.1x57.2x39.4cm 71.1x57.2x39.4cm (27.99x22.52x15.51in) (27.99x22.52x15.51in) (27.99x22.52x15.51in)

Devicemounting Wallmount(backplateincluded) Wallmount(backplateincluded) Wallmount(backplateincluded)

Ambientairtemperatureforoperation -25°Cto70°C(-13°Fto158°F)(powerderatedabove45°C(113°F))

Communicationnetworktype Xanbus™ Xanbus™ Xanbus™

Partnumber 865-1035 865-1040 865-1045

Features and options Displaytype StatusLEDsindicateACInstatus,faults/warnings,equalizemode,On/Offandequalizebuttonbatterylevel.

Three-characterdisplayindicatesoutputpowerorchargecurrent

Supportedbatterytypes Flooded(default),Gel,AGM,custom Flooded(default),Gel,AGM,custom Flooded(default),Gel,AGM,custom

Batterybanksize 100to2000Ah(scaledtoPVarraysize)

Batterytemperaturesensor Included Included Included

Nonvolatilememory Yes Yes Yes

Multipleunitconfigurations Single-phase:uptofourparallelunits.Three-phase:twounitsperphase

Optional components (seepage72formoredetails)XantrexXWRemotedisplay(865-1050) XWSCPmonitorsandconfiguresalldevicesconnectedtoXanbusNetwork

XantrexXWGeneratorsupport(865-1060) XWAGSmoduleconnectstoXanbusNetwork.Automaticallyactivatesgenerator torechargedepletedbatterybank orassistinverterwithheavyloads

XantrexXWConduitBox(865-1025) XWCBenclosesthebottomoftheinverterandprotectsthecabling.Providesknockoutsfor2cm,2.5cm,3.2cm, 6cm,and6.5cmconduit

XantrexXWMPPT60150(865-1030-1)(page60) XWMPPTSolarChargeControllerwithMPPTdeliversthemaximumenergyavailablefromthePVarray XantrexXWMPPT80600(865-1032)(page62) tothebatterybank

XantrexXWConfigurationTool(865-1155) XantrexXWConfigurationToolaidsdealersandinstallersbysimplifyingandexpeditingtheconfiguration and/ortroubleshootingofaXantrexXWSystem

Regulatory approvalCEmarkedaccordingtothefollowingEUdirectivesandstandards:

EMCDirective EN61000-6-1,EN61000-6-3,EN61000-3-2,EN61000-3-3

LowVoltageDirective EN50178

Specificationsaresubjecttochangewithoutnotice.

2322

Schneider Electric Xantrex™ XW MPPT 60 150 Solar Charge Controller

TheXantrexXWMPPT60150isaphotovoltaic(PV)chargecontroller thattracksthemaximumpowerpointofaPVarraytodeliverthe maximumavailablecurrentforchargingbatteries.Whencharging, theXantrexXWMPPT60150regulatesbatteryvoltageandoutput currentbasedontheamountofenergyavailablefromthePVarray andstate-of-chargeofthebattery.

Features •Canbeusedwith12,24,36,48,and60Vbatterysystemsandis abletochargealowernominalvoltagebatteryfromahighernominal voltagearray

•MaximumPowerPointTracking(MPPT)algorithmcontinuallyseeks themaximumpoweravailablefromthePVarray

• IntegratedPVgroundfaultprotectionfornegativegroundedarrays

•Convection-cooleddesigndoesnotrequireacoolingfan−large, aluminum,die-castheat-sinkallowsfulloutputcurrentupto45°C withoutthermalderating

•Selectabletwoorthree-stagechargingalgorithmswithmanual equalizationtomaximizesystemperformanceandimprovebatterylife

•Configurableauxiliaryoutput

•2lines16digitLCDandfourbuttons forconfigurationandsystemmonitoring

• Inputover-voltageandunder-voltageprotection,outputover-current protection,andbackfeed(reversecurrent)protection(warningandfault messagesappearonLCDwhenunitshutsdownasaprotectivemeasure)

•Canalsobeusedwithotherbattery-basedsolarenergysystems

•Over-temperatureprotectionandpowerderatingwhenoutputpower andambienttemperaturearehigh

•BatteryTemperatureSensor(BTS)included−automaticallyprovides temperaturecompensatedbatterycharging

•Xanbus™-enablednetworkcommunicationsprotocol

•Five-yearstandardwarranty

> Solar charge controllers

Off-grid and backup

Xantrex™ XW MPPT 60 150

Device short name XW MPPT 60 150

Electrical specificationsNominalbatteryvoltage 12,24,36,48,60V

Max.PVarrayvoltage(operating) 140V

Max.PVarrayopencircuitvoltage 150Vincludingtemperaturecorrectionfactor

Max.arrayshort-circuitcurrent 60A(48A@STC)

Max.chargecurrent 60A

Max.andmin.wiresizeinconduit #6AWGto#14AWG(10to2.5mm²)

Chargerregulationmethod Three-stage(bulk,absorption,float)plusmanualequalization Two-stage(bulk,absorption)plusmanualequalization

General specificationsPowerconsumption,nighttime 2.5W

Enclosurematerial Indoor,ventilated,sheetmetalchassiswith2.2cmand2.8cm(7/8inand1in)knockoutsandaluminiumheat-sink

Productweight 4.8kg(10.75lb)

Shippingweight 8kg(17.6lb)

Productdimensions(HxWxD) 36.8x14.6x13.8cm(14.5×5.75×5.5in)

Shippingdimensions(HxWxD) 48.3x22.9x35cm(19×9×9.75in)

Devicemounting Verticalwallmount

Ambientairtemperatureforoperation(fullpower) -20°Cto45°C(-4°Fto113°F)

Storagetemperaturerange -40°Cto85°C(-40°Fto185°F)

Operatingaltitude Sealevelto2000m(6562ft)

Warranty Five-yearstandard

Partnumber 865-1030-1

Features and optionsDisplaytype LCD,2lines16digits

Regulatory approvalsSafety CSACertified(UL1741rev.2005,CSA107.1)andCEMarkedfortheLowVoltageDirective(EN50178)

EMC FCCandIndustryCanada(ClassB)andCEMarkedfortheEMCDirective(EN61000-6-1,-6-3)

Specificationsaresubjecttochangewithoutnotice.

2524

Schneider Electric Xantrex™ XW MPPT 80 600 Solar Charge Controller

TheXWMPPT80600isaninnovativesolarchargecontrollerthatoffersanindustry-firstsetoffeatures:highPVinputvoltage(upto600Vdc),MaximumPowerPointTracking(MPPT),and80Achargecurrent.600VdcPVinputvoltagedeliverslowerinstallationcoststhroughfewerPVstrings,longerhomeruns,smallerwiringandconduit,andvirtualeliminationofPVcombinerboxesandcircuitbreakers.MPPTtechnologyhelpsharvestthemostenergyavailablefromthePVarray,regardlessofenvironmentalconditions.80Abatterychargecurrentallowsforconnectionofarrays ratedatupto4800W(48Vbatterybank).

Features •Acceptsarrayvoltagesupto600V,increasinginstallationflexibility andreducinginstallationcost

•MPPTtoimproveenergyharvestoverawiderangeofenvironmental conditions

•80AchargecurrentfromlargePVarrayswithjusttwostrings

•Charges24Vor48Vbatterybanks

•Fulloutputpowerat45ºCwithoutderating(2560Wfor24Vsystems, 4800Wfor48Vsystems)

•Configurableforpositive,negative,andungroundedPVsystems

• IntegratedPVgroundfaultprotection

•ConfigurableAuxiliaryoutput

• Inputover-voltageandunder-voltageprotection,outputovercurrent protection,andbackfeed(reversecurrent)protection

•Over-temperatureprotectionandpowerderatingwhenambient temperaturesarehigh

•BatteryTemperatureSensor(BTS)included–automaticallyprovides temperaturecompensatedbatterycharging

•Xanbus™–enablednetworkcommunicationsprotocolallowssettings andactivitytobecommunicatedtootherXanbus-enableddevices,such astheXWHybridInverter/Charger,theXWSystemControlPanel(SCP), XWAutomaticGeneratorStart(XWAGS)andotherXWSolarCharge Controllers

•Provideson-boardXanbus™networkpowerforuseinstand-alone applicationswithcommunicationsgateway

•Canbeinstalledinastand-alonemodewithXWSystemControlPanel (XWSCP)(soldseparately)

•Five-yearstandardwarranty

> Solar charge controllers

SchneiderElectricXantrexXWSCP

Off-grid and backup

Xantrex™ XW MPPT 80 600

Device short name XW MPPT 80 600

Electrical specificationsNominalbatteryvoltage 24and48V(Defaultis48V)

Max.PVarrayvoltage(operating) 195to550V

Max.PVarrayopencircuitvoltage 600Vincludingtemperaturecorrectionfactor

Arrayshort-circuitcurrent 35A(28A@STC)

Max.chargecurrent 80A

Max.andmin.wiresizeinconduit #6AWGto#14AWG(13.5to2.5mm2)

Chargerregulationmethod: Three-stage(bulk,absorption,float)plusmanualequalization Two-stage(bulk,absorption)plusmanualequalization

General specificationsPowerconsumption,nighttime <1W

Enclosurematerial Indoor,ventilated,aluminumsheetmetalchassiswith22.22mmand27.76mm(7/8inand1in)knockouts andaluminumheatsink

Productweight 13.5kg(29.8lb)

Shippingweight 17.4kg(38.3lb)

Productdimensions(HxWxD) 76×22×22cm(30×8.625×8.625in)

Shippingdimensions(HxWxD) 87×33×27cm(34.3×13×10.6in)

Devicemounting Verticalwallmount

Ambientairtemperatureforoperation -20°Cto65°C(-4°Fto149°F),powerderatingabove45°C

Storagetemperaturerange -40°Cto85°C(-40°Fto185°F)

Operatingaltitude Sealevelto2000m(6562ft)

Warranty Five-yearstandard

Partnumber 865-1032

Regulatory approvalsCertifiedtoUL1741:2ndEdandtoCSA107.1-01

Specificationsaresubjecttochangewithoutnotice.

2726

Schneider Electric Xantrex™ C12 PWM Charge Controller

TheXantrexC12PWMcharge,lighting,orloadcontrollerisuniquelysophisticated.Asachargecontroller,itfeaturesthree-stagecharging, userdefinablevoltageparameters,andautomaticequalization.StandardintheXantrexC12PWM’sloadcontrolcircuitryarefieldadjustablelowvoltagedisconnectandreconnectpoints,alongwithafiveminutelowbatterydisconnectwarning.TheXantrexC12PWMalsofunctionsasalightingcontroller.Lightingruntimeisadjustablefromtwotoeighthours orcanbesetfromdusktodawnoperation.Itisusedworldwideinavarietyofapplications,includingremotevillagelightingsystemsandautomaticoutdoorlighting.Anoptionalbatterytemperaturesensorensuresprecisebatterychargingregardlessofbatterytemperaturefluctuations.

Features•Silent,pulsewidthmodulatedmicroprocessorcontrol(maximizing batterylife)

•Fieldadjustablevoltageandbatterysetpoints

•Electronicprotectionagainstshort-circuit,overload,over-temperature andreversepolarityconditions

•Two-yearstandardwarranty

> Solar charge controllers

Off-grid and backup

Xantrex™ C12 PWM

Device short name C12 PWM

Electrical specificationsRatedPVcurrent 12Aat12Vonly

Max.DCload 12Awithautoreset

Min.operatingvoltage 6V

Max.voltagedrop(PVtobattery) 0.3V

Max.voltagedrop(batterytoDCload) 0.5V

Regulationsetting 13to15V

Equalizesetting Bulkplus1voltfortwohours

Max.strandedwiresize #10AWGstranded(5.2mm2)

Typicalconsumptionwhilecharging 0.007A

Typicalconsumptionwithloaddisconnected 0.003A

General specificationsPowerconsumption,nighttime 0.003A

Enclosurematerial Powdercoatedsteelwithstrainreliefforwiringandknockoutsforupto3.5inconduits

Productweight 0.9kg(1.98lb)

Shippingweight 1.13kg(2.49lb)

Productdimensions(HxWxD) 16.5x11x4cm(6.5x4.33x1.57in)

Shippingdimensions(HxWxD) 20.3x11.7x4cm(7.99x4.61x1.57in)

Devicemounting Verticalwallmount–indooronly

Ambientairtemperatureforoperation 0°Cto40°C(32°Fto104°F)

Warranty Two-yearstandard

Partnumber C12–chargecontroller

Features and optionsRegulationmethod Standard–three-stage(bulk,absorption,andfloat),solidstate,pulsewidthmodulation

Fieldadjustablecontrolsetpoints Standard–removableknobsandcalibratedscales

Settingprotection Standard–knobscanberemovedtopreventtampering

Testpoints Standard–providedforeachsetting

Automaticequalization Standard–every30daysoraftervoltagereacheslowvoltagedisconnect–canbedisabled

Externalbatterytemperaturecompensation Optional–batterytemperaturesensor(BTS)

Shortcircuitprotection Standard–fullyelectronicallyprotectedwithautoresetandmanualresetswitch,protectsboththeloads andPVarrayfromdamagefromshortcircuits–afuseforthebatteryisstilladvisedtoprotect thebatterywiresiflocatedseparately

Reversepolarityprotection Standard–fullyprotected

Lowvoltagedisconnect Standard–adjustableautomaticormanualoperation,manualreconnectionincludeswarningflash ofloadsfiveminutesbeforeandatenminutegraceperiod

Regulatory approvalsCEmarkedfortheLowVoltageDirectiveandEMCDirective

Specificationsaresubjecttochangewithoutnotice.

2928

Schneider Electric Xantrex™ C Series Controller

TheXantrexC35PWMandC60PWMarefieldconfigurablefor 12-and24-Voperation.TheXantrexC40PWMmaybeconfigured for12-,24-,or48-Voperation.Allcanbeusedasacharge,diversion, orloadcontrollerandcomewithastandardmulti-colorchargestatusLED.

Features•Silent,pulsewidthmodulatedmicroprocessorcontrol (helpingtomaximizebatterylife)

•Fieldadjustablevoltageandbatterytypesetpoints

•Electronicprotectionagainstshort-circuit,overload, over-temperature,andreversepolarityconditions

•Two-yearstandardwarranty

C Series•CM:Cumulativeamphourmeter

•CM/R:Remotecumulativeamphourmeter (availablein50or100footlengths)

•BTS:Batterytemperaturesensor

Optional components: CM and CM/R Digital Meter or Remote DisplayThisdigitalmetermountsontothefrontofachargecontrolleroras aremoteitcanbeinstalledupto31maway.Itdisplaysvolts,amps, andresettablecumulativeamphoursforasolararray,DCloads, ordiversionloads,dependingontheapplication.TheCM/Rcomes with15or30.5mcommunicationcableforremoteinstallation.

> Solar charge controllers

Off-grid and backup

Xantrex™ C Series

Device short name C35 PWM C40 PWM C60 PWM

Electrical specificationsRatedPVcurrent 35A 40A 60A

Charging/loadcurrent@25°C(77°F) 35A 40A 60A

Voltageconfigurations 12and24V 12,24,and48V 12and24V

Max.PVopencircuitarrayvoltage 55V 125V 55V

Max.voltagedropthroughcontroller 0.30V 0.30V 0.30V

Totaloperatingconsumption 15mA 15mA 15mA

Recommendedbreakersize 60Aratedat100%continuousduty 60Aratedat100%continuousduty 60Aratedat100%continuousduty

Recommendedwiresize #6AWGratedat90°C(194°F) #6AWGratedat90°C(194°F) #6AWGratedat90°C(194°F)

Leadacidbatterysettings Adjustable Adjustable Adjustable

NiCdbatterysettings Adjustable Adjustable Adjustable

Loadcontrolmode Lowvoltagereconnect–adjustable(stickerprovidedwithunit)allmodels Lowvoltagedisconnect–userselectablemanualorautomaticreconnection– (includeswarningflashbeforedisconnectandprovidesaonetime,userselectedgraceperiod)allmodels

General specificationsPowerconsumption,nighttime 3mA 3mA 3mA

Enclosurematerial Indoor,ventilated,powdercoatedsteel Indoor,ventilated,powdercoatedsteel Indoor,ventilated,powdercoatedsteel with2cmand2.5cmknockouts with2cmand2.5cmknockouts with2cmand2.5cmknockouts

Productweight 1.2kg(2.65lb) 1.4kg(3.09lb) 1.4kg(3.09lb)

Shippingweight 1.4kg(3.09lb) 1.6kg(3.53lb) 1.6kg(3.53lb)

Productdimensions(HxWxD) 20.3x12.7x6.4cm 25.4x12.7x6.35cm 25.4x12.7x6.35cm (7.99x5x2.52in) (10x5x2.5in) (10x5x2.5in)

Shippingdimensions(HxWxD) 31.5x17.8x6.4cm 31.5x17.8x6.4cm 31.5x17.8x6.4cm (12.4x7.01x2.52in) (12.4x7.01x2.52in) (12.4x7.01x2.52in)

Devicemounting Verticalwallmount–indooronly Verticalwallmount–indooronly Verticalwallmount–indooronly

Ambientairtemperatureforoperation 0°Cto40°C(32°Fto104°F) 0°Cto40°C(32°Fto104°F) 0°Cto40°C(32°Fto104°F)

Operatingaltitude 4572m(15000ft) 4572m(15000ft) 4572m(15000ft)

Non-operatingaltitude 15240m(50000ft) 15240m(50000ft) 15240m(50000ft)

Warranty Two-yearstandard Two-yearstandard Two-yearstandard

Partnumber C35,C40,C60–chargecontrollers CM–Frontdisplaypanel CM/R-50,CM/R-100–Remotedisplaypanel BTS–Batterytemperaturesensor

Features and optionsDisplaytype CM,CM/R-50,orCM/R-100–optionalLCD–backlit,alphanumericdisplayshowingbatteryvoltage,DCamperage, cumulativeamphours,andamphourssincelastreset–remoteincludes15or30.5m(49or100ft)cable

Regulationmethod Solidstate,three-stage(bulk,absorption,andfloat),pulsewidthmodulation

Fieldadjustablecontrolsetpoints Twouseradjustablevoltagesetpointsforcontrolofloadsorchargingsources– settingsretainedifbatteryisdisconnected

Equalizationcharge Userselectablemanualorautomaticequalization–every30days

Batterytemperaturesensor BTS–optionalremotebatterytemperaturesensorforincreasedchargingprecision

Regulatory approvalsSafety ULListedtoUL1741andCSA14;CEMarkedfortheLowVoltageDirective

EMC FCCandIndustryCanadaClassB,CEMarkedfortheEMCDirective

Specificationsaresubjecttochangewithoutnotice.

33

Solar solution components and PV protection

3231

Schneider Electric Xantrex™ Gateway

TheXantrexGatewaybridgesthegapbetweenaXantrexGTorXWSystemandthesystemowner’scomputer,makingitthecentralcomponentfor aresidentialorsmallcommercialremotemonitoringsystem.

TheXantrexGatewaylogsperformancedatadirectlyfromtheXantrexGTorXWSystem,andtransmitsittotheincludedwidget-basedmonitoringsoftwareforasimpleandgraphicallyrichviewofsystemperformance.Morethanadatalogger,theXantrexGatewayoffersawebpagewiththeabilitytoconfigureautomatedemailreportsandfaultstatustotheuser orinstaller.

TheXantrexGatewayincludesbothbuilt-inWi-FiandEthernetconnectivityallowingforflexibleandsimplesetupforwirelessorwiredconnectionto arouterordirecttoaPC.

The Xantrex Gateway logs and transmits performance data including:•Systempowerproduction

• Inverterspecificpowerproduction

•Lifetimeenergyproduction;daily,weekly,monthlyenergyproduction graphs

• Inverterfaultswithdateandtimestamp

Features•Canmonitoranetworkconsistingofupto20singlephaseGT invertersoruptoeightXantrexXWdevices(XantrexXWInverter/ Charger(s),XantrexXWMPPTSolarChargeController(s), XantrexXWSCP,andXantrexXWAGS)

•Wi-Fi/Ethernetmodulewith10/100Base-Tor802.11b/g

•Canbeconfiguredtosendenergyandalarmreportsviaemail

•Graphicalinteractivesolarmonitoringsoftware

•EmbeddedwebpageforconfiguringtheXantrexGatewayandupgrading inverterfirmware

•16megabytesofstorage

Components

Xantrex™ Gateway

Electrical specificationsCommunication Physicallayer2,CAN

Communicationprotocol Xanbus™

Max.Xanbuscablelength 40m(131ft)

Max.Ethernetcablelength 60m(197ft)

Connectors 3RJ45–8pins(twoXanbus,oneEthernet)

Communication specificationsEthernet IEEEStd802.3-2005™

Wireless 802.11.4band802.11.4g;WEPandWPAsecurity Channels1-11(US/Canada),1-9(Europe)

General specificationsProductweight 0.21kg(0.46lb)

Productdimensions(HxWxD) 11.2x19.0x45cm(4.41x7.48x17.72in)

Heightincludingantenna 24.9cm(9.8in)

Partnumber 865-1056

Regulatory approvals NorthAmerica EMCFCCandIndustryCanadaclassB

Europe Safety LowVoltageDirectiveEN60950-1 EMC EMCDirectiveEN55022,EN55024 Telecom R&TTEDirective,ETSIEN301489-1,ETSIEN301489-17

Specificationsaresubjecttochangewithoutnotice.

3433

Schneider Electric XantrexTM XW System componentsSchneider Electric Xantrex™ XW SCP*

(865-1050)

TheXantrexXWSystemControlPanelfeaturesagraphical,backlitLCDdisplaythatprovidessystemconfiguration anddiagnosticinformationfordevicesconnectedtotheXanbus™-enablednetwork.TheXWSCPgivesasingle pointofcontroltosetupandmonitoranentiresystem,whichmayconsistofmultipleXantrexXWInverter/Chargers,XantrexXWMPPTSolarChargeControllersandothercomponents.

Schneider Electric Xantrex™ XW AGS*

(865-1060)

TheXantrexXWAutomaticGeneratorStartwillautomaticallyactivateageneratortoprovideanXantrex XWInverter/Chargerwithpowertorechargeadepletedbatterybankorprovideadditionalpowerforheavyloads. TheXWAGSaddsintelligencetogeneratormanagement,therebyeliminatingtimespentmonitoringbatteriesandinverterloads.

Schneider Electric Xantrex™ XW CB(865-1025)

TheXantrexXWConduitBox,isabareconduitbox(nowires)thatcanbeusedtocreatesystemslargerthan twoinverters,ortoretrofitXantrexXWInvertersintoexistingsystemswhichmayalreadyhaveAC/DCdisconnects.

Schneider Electric Xantrex™ XW CK(865-1020)

TheXantrexXWConnectionKitisawiringkitandconduitboxusedtoconnectasecondinvertertoaXantrexXW PowerDistributionPanel.Allwiresaremeasured,pre-cutandlabeledtofacilitatequickandeasyinstallation.

Schneider Electric Xantrex™ XW PDP(865-1015)

TheXantrexXWPowerDistributionPanelwhichcomeswithaconduitboxisfactory-wiredandlabeledtosupportacode-compliantsingle-inverterinstallation.InternalwiringandbreakerscanbeaddedtoexpandtheXWSystemwithuptothreeinverters,fourchargecontrollers,orotherequipmenttosupportlargersystems.

Schneider Electric Xantrex™ XW CT(865-1155)

TheXantrexXWConfigurationToolisaPC-basedtool(applicationandnetworkadapter)thatprovidesforversatileXWsystemanalysis,configuration,andrecordingofsystem-andindividualcomponent(XWInverter/Charger,XWChargeController,XWAGS)settings.Toolwizardsenhancetheconfigurationprocess,theXantrexXWCTcanbeusedtoupdatecomponentfirmware–rightinthefield!

* Meets regulatory approvals: CSACertified(UL458andCSA107.1) EMCDirective:FCCandIndustryCanadaClassB,andCEmarkedfortheEMCDirective(EN61000-6-1,-6-3).

Components

Photovoltaic installations componentsSchneider Electric Solar Disconnect Switch(REHU393IP(3Poles,100Amps),REHU493IP(4Poles,100Amps),REHU394IP(3Poles,200Amps),REHU494IP(4Poles,200Amps))

The1000VDCdisconnectswitchfunctionsasalocaldisconnectforastringofPVpanelsandisIEC60947compliantforuseinPhotovoltaicSystemsatamaximumof1000VDC.Thiscompactdisconnectisavailableinboth100and200amp,three-poleandfour-poleversions.

Single or multi-inverter PV system componentsSchneider Electric Xantrex™ GT SIM*

(864-0203)

TheXantrexGridTieSolarInverterMonitorfeaturesagraphical,backlitLCDscreentomonitoryoursingleormulti-inverterPVsysteminoneconvenientlocationinsidethehome.TheXantrexGTSIMisasimplemeansofmonitoring yoursolarsystem,withitslargekeypadbuttons,anintuitiveon-screenmenusystem,andplaintextstatusmessages tomakethemonitoreasytoreadanduse.ThemonitoreasilyconnectstoXantrexGTSeriesinvertersusingstandard CAT5Ethernetcablethatalsoprovidespowertothemonitor.Built-inflashmemorystoresPVsystemdataandmakessoftwareupgradessimple.

XantrexTM C Series Charge Controller componentsSchneider Electric Xantrex™ BTS(130-0004)

TheXantrexBatteryTemperatureSensormountsonyourbatteryandmeasuresitstemperature.ItsendspreciseinformationtoanInverter/ChargerorChargeController,whichautomaticallyadjustschargingvoltagetoensure fullbatterycharge,regardlessoftheambienttemperatureofyourbatteryinstallation.

* Meets regulatory approvals: CSACertified(UL458andCSA107.1) EMCDirective:FCCandIndustryCanadaClassB,andCEmarkedfortheEMCDirective(EN61000-6-1,-6-3).

3635

DC circuit protectors for Photovoltaic installationsSchneider Electric C60PV-DCTheC60PV-DCisaDCcircuitbreakerdedicatedtomultistringforPVinstallationswithVocuntil650V. ItisolatesPVstringsandprotectsthemfromreversecurrent.TheC60PV-DCisnotpolaritysensitive. •Threeratings:10,16,and20A

Schneider Electric Compact NS DC circuit breakerTheCompactNSDCisaDCcircuitbreakerdedicatedtomulti-arrayphotovoltaicinstallationwithVocuntil750V (pleaseconsultforhighervoltage).ItisolatesPVsub-arraysandprotectsthemfromreversecurrent. •Ratingsfrom80Ato250A(fourpoles)

Schneider Electric Masterpact NW DC

TheMasterpactNWDCistheworldwidebenchmarkforhigh-currentcircuit-breakers.TheMasterpactNWcircuit-breakerrangefeaturesoptimiseddimensions.Thisunitmeetsrequirementsfrom4000to6300A.Atatimewheninstallationsarebecomingincreasinglycomplex,MasterpactNWenablesstandardisationofelectricalswitchboardsbyprovidingunrivalledsimplicityintermsofbothchoiceandinstallation.

Schneider Electric NSX DC PV

TheCompactNSXisthenext-generationcircuitbreaker.Apowermonitoringunitenhancesitsprotectivefunctions. Forthefirsttime,userscanmonitorbothenergyandpower,offeringnewperformanceinaremarkablycompactdevice.

DC main switch for photovoltaic installationsSchneider Electric C60NA-DCTheC60NA-DCisanun-polarizedDCswitchdisconnectordedicatedtoarrayisolationandcontrolwithVoc until650V.Whenfusesareprovidedforovercurrentprotection,theuseofC60NA-DCisrequired. •Operatingcurrentandvoltage:20A-650V;30A-500V;40A-400V;50A-300V

Schneider Electric INS PV-1TheINSPV-1isaDCswitchdisconnectordedicatedtoarrayisolationandcontrolwithVocuntil600V. DesignedformaximumperformanceandsafetyforPVapplications,thisproductoperateswithawidechoice ofaccessoriesandauxiliaries. •Operatingcurrentandvoltage:10A-600V;25A-500V;32A-400V

Schneider Electric Compact NS DC switch disconnectorTheCompactNSDCswitchdisconnectorisdesignedforDCVoltageupto750V(pleaseconsultforhighervoltage). ItisdedicatedtoarrayisolationorasamainDCswitch.ForPVinstallationthisproductoperateswithfour-polebasicframesequippedwithaccessories(phasebarrier,poleconnections,rotaryhandleetc.).

Protection

Protection against lightning strikesSchneider Electric PRD-DC surge arrestersThePRD-DCdirectcurrentsurgearresterisdesignedtohelpprotectPVpanelsandtheDCinputtotheinverter fromover-voltagesduetoalightningstrike.Itshouldbeinstalledinanenclosure,weatherproofifinstalledoutside. ThewithdrawablePRD-DCallowsdamagecartridgestobereplacedquickly. •Ratings:40kA,600and1000V •Werecommendthisproducttobeusedwithmini-Kaedraenclosures

Schneider Electric AC surge arresters with built-in disconnectorAlargerangeofACsurgearrestersaredesignedtohelpprotectyourPVinstallationagainstlightninginducedsurges.Eachsurgearresterintherangehasaspecificuse: •Highrisklevel:withmax.40kA(QuickPRD40rsingle-phaseandthree-phase) •Moderaterisklevel:withmax.10,12.5,20kA(PF’clic,QuickPRD20rsingle-phaseandthree-phase)

Schneider Electric TeSys DF PV

Simpleandeffectiveprotection.Fuseprotectionisareliableandeffectivesolutiontoprotectyourlowvoltageequipmentagainstshort-circuitsthatcancausemajordamagetoyourinstallationsandgenerateriskforequipmentandpersonnel,aswellassignificantproductionlosses.

37

Alternating current (AC)Thetypeofelectricitysuppliedbytheutilitycompany. Theuniquecharacteristicofthisformofelectricityisthatitreversesdirectionatregularintervals.Forexample,230V50Hzpowerreversesflow50times asecond,hencetherating50Hz(cycles).

Amp (A)Aunitofmeasureoftheflowofelectricalcurrent.

Amp hour (Ah)Oneampofelectricalcurrentflowingforonehour. TheunitAhisanexpressionofthecapacity(size) ofabattery.

CurrentTherateofflowofelectriccharge,usuallyexpressed inamps(oramperes).

Direct current (DC)Thetypeofelectricitystoredinbatteriesandgeneratedbysolarelectricdevices.Currentflowsinasingledirection.

ElectrolyteAconductivemediuminwhichtheflowofelectricitytakesplace;thisistheliquidfoundinsidestoragebatteries.

GridWhenusedinreferencetoutilitypower,itreferstoasystemofelectricaltransmissionanddistributionlines.

Ground fault protection (GFP)Ashockhazardprotectiondevicethatlimitstheflowofelectricalcurrenttoearth.Usuallyrequiredinwetlocations,e.g.foroutdoor,kitchen,andbathroomcircuits.

Hertz (Hz)

Thefrequency,ornumberoftimespersecond,that theflowofACelectricityreversesitself.Alsoreferred toascycles(seealternatingcurrent).

High battery voltage protectionAcontrolcircuitthatdisconnectschargecurrentflowingtothebatterybeforevoltagereachesadangerouslyhighthreshold.Preventsdamagecreatedbyexcessgassing(orboiling)ofelectrolyte.

Idle currentTheamountofelectricalcurrentrequiredtokeep aninverterreadytoproduceelectricityondemand.

Inrush currentThepeakcurrentanapplianceortoolwilldrawat theinstantitstartsup.

Kilowatt (kW)OnethousandWattsofelectricity.Ten100WattlightbulbsuseonekWofelectricalpower.

Kilowatt hour (kWh)OnekWofelectricalpowerusedforonehour.MostgridconnectedelectricalmetersmeasurekWhforbillingpurposes.

Line lossAvoltagedropcausedbyresistanceinwireduring transmissionofelectricalpoweroverdistance.

LoadAnydevicethatconsumeselectricitytooperate.Appliances,tools,andlightsareexamplesof electricalloads.