Metodo de Cross

Preview:

DESCRIPTION

.l.

Citation preview

Hoja1CALCULO ESTRUCTURAL DE EDIFICIOPREDIMENSIONAMIENTO DE LOSA ALIGERADA:L=5C=25h=0.200.2Y=h-0.050.15PREDIMENSIONAMIENTO DE VIGASTomar la mayor luz :VIGA PRINCIPALVIGA SECUNDARIAL6L =5C12C=14Peralteh0.50h =0.360.40anchob=0.25b=0.20.25CARGASDE TECHO ALIGERADOLadrillo=cantidad=8.30peso=8.0066.40Kg/m2Vigueta=b=0.10Y=0.15p= Kg/m32400.00cantidad=2.5090.00Kg/m2Losa=t=0.05p= Kg/m32400.00120.00Kg/m2276.40Kg/m2Seg. R.N.Eq =300.00AzoteaPeso propio300.00piso tipicoPeso propio300.00Acabado100.00Acabado100Tabiqueria100Tot. Carga muerta400.00500.00Kg/m2Carga viva150Carga viva segn uso200Kg/m2PESO DE MUROS POR m2M.cabezaM.sogaNo Pisos5V total de M0.250.15Altura de C. P3V de ladrillo0.210.135COLUMNA (ASUMINDO)V.mortero=0.040.015b=0.3P.ladrillo224144t=0.3P.Mortero9234.5H=3P.Muro316178.5PESO648Tarrajeo6969P.MuroAcab385247.5Por ml1155742.5DE VIGASAREA TRIBUTARIACARGA MUERTACARGA VIVAVIGA PRIN.VIGA SEC.VIGA PRIN.VIGA SEC.L1 =5l2 =4a t=4.514.51CARGA POR Kg/mlVIGA PRINCIPALVIGA SECUNDARIAAzoteaPiso tipicoAzoteaPiso tipicoLosaw = qa18002250400500Peso propio2400bh300300192192Muro742.50742.5CARGA MUERTA POR ml21003292.55921434.5Kg/mlCARGA VIVA POR ml675900150200Kg/mlCOLUMNASLx1=Lx2=X=Ly1=Ly2=Y=Area tributCOL. INT. A565.5454.524.75COL. EXT. C2502.5454.511.25ESQUINA C4502.50425AREA TRIBUTARIAAt =XY =At =24.755.54.5CM24.75CVNivellosaV.PV.S.ColumnaP. ca. NivelAcumuladaCvpor pAcumuladaP(Tn)59900165086412.41412.413.710.090.0912.51412375165086464815.53727.954.950.120.2128.17312375165086464815.53743.494.950.120.3443.82212375165086464815.53759.034.950.120.4659.48112375165086464815.53774.564.950.120.5875.140000000.000.000.000.000.00-1000000.000.000.000.000.00-2000000.000.000.000.000.00-3000000.000.000.000.000.00-4000000.000.000.000.000.00-5000000.000.000.000.000.00XSeccion. rectangularSeccion.cuadradaPCnF'ct1 = c1c2c'2tTse toma512.511.250.321000.250.100.250.160.250.3428.171.250.321000.250.220.250.240.250.3343.821.250.321000.250.350.350.290.290.3259.481.250.321000.250.470.470.340.340.4175.141.10.321000.250.520.520.360.360.4Sec. de columna00.001.10.321000.250.000.250.000.250.3-10.001.10.321000.250.000.250.000.250.3-20.001.10.321000.250.000.250.000.250.3-30.001.10.321000.250.000.250.000.250.3-40.001.10.321000.250.000.250.000.250.3-50.001.10.321000.250.000.250.000.250.3CARGA SISMICA: METODO ESTATICODIMENSIONES=L.Ca.vigaNo de vigasLog total (m)P. Unit.CRUJIAS EN X =564.515.5462300Kg/mlCRUJIAS EN Y =45413452192Kg/mlArea de losa201.5CMAzotea400.00Kg/m2201.5CMP.tipico500.00Kg/m3201.5CVAzotea150Kg/m4201.5CVP.tipico200Kg/m5HC1C2P.cad. Col.CantidadP. TotalColumna30.250.522400944.6798502.00Kg.AZOTEAPESO POR PISO (Tn) =PESO DE LOSA = Lx.Ly.W=8060088156.25VIGA PRINCIPAL= L*Wvp18,600.0018,600.00VIGA SECUNDARIA= L*Wvs99849,984.00COLUMNA = 1/2Lz*Wc4,251.004,251.00TnCARGA DE AZOTEA =120991.2497160714120.99PISO TIPICO :P. DE LOSA = Lx*Ly*W100750110825P. DE VIGA PRINCIPAL= L*Wvp18600.0018600.00P. DE VIGA SECUNDARIA= L*Wvs9984.009984.00PESO DE COLUMNA = N*Lz*Wc8,502.008502.00CARGA DE PISO TIPICO =147910.9994321428147.91COEFICIENTE SISMICO:C/R > 0.125Z = FACTOR DE ZONAZONAZ=30.420.310.15U = FACTOR DE USOA = EDIFICIOS ESCENCIALES1.5B = EDIFICIOS IMPORTANTES1.3C = EDIFICIOS COMUNES1D = EDIFICIOS MENORESCRITERIO PERSONALSTpS = FACTOR SUELOS1 = Roca - Suelo muy rigido =10.4S2 = Suelo intermedio =1.20.6S3 = Suelos flexibles - Estrato grande1.40.9C = COEFICIENTE DE AMPLIFICACION SISMICAT = hn/Cthn = ALTURA DEL EDIFICIO (m)18Ct = Para edificios aporticados350.51C = 2.5(Tp/T) < 2.52.922.50Ct = Para edificios con porticos - placas - escaleras - ascensores4.5R = COEFICIENTE DE REDUCCION DE SOLICITACIONES SISMICASACERO :R=PORTICOS DUCTILES CON UNIONES RESISTENTES A MOMENTOS9.5OTRAS ESTRUCTURAS DE ACERO8.5ARRIOSTRES EXCENTRICOS6.5ARRIOSTRES EN CRUZ6CONCRETO ARMADOPORTICOS8PORTICOS Y PLACAS7DE MUROS ESTRUCTURALES6MUROS DE DUCTILIDAD LIMITADA4ALBAILERIA ARMADA O CONFINADA3MADERA (Por esfuerzos admisibles)7ZUSC/R =0.1750Para calcular por SAP (respuesta espectral)V=(ZUSC/R)P =712.64TpTC=2.5Tp/TTomar