Medical Vacuum Plant & AGSS(Anaesthetic Gas Scavenging System) Plant
MEDICAL VACUUM SYSTEM
Rotary Vane Vacuum Pumps➠Air cooled (no cooling water consumption)
➠Suction capacity from 4 to 1,500 m3/h
➠Vacuum up to 10 mbar (abs.)
➠High efficiency, low energy consumption
Claw Vacuum Pumps - The Alternative➠Air cooled and dry running
➠Suction capacity from 60 to 600 m3/h
➠Vacuum up to 50 mbar (abs.)
➠High efficiency, virtually free of maintenance
All Pumps (Rotary Vane And Claw)Are Fitted With➠Inlet screen filter
➠Non-return valve
➠Manually operated check valve
➠Option: electrically operated check valve
Vacuum Vessel➠Vertical or horizontal configuration
➠Vessel capacities from 100 to 5,000 liters
➠With vacuum gauge, condensation drain valve
and connecting accessories
Control System➠System programming by way of operator display
➠All motors feature independent power supply circuits
➠Load alternation circuit as standard
➠Digital vacuum display
➠Function monitoring by way of LCD display
(on/off, fault, maintenance, operating hours meter)
➠Option: remote monitoring
➠Adjustable for day/night operation
Accessories➠Anti-bacterial filters
➠Fine-grade inlet filter
➠Condensate separator
➠Additional: sound insulating enclosure
RMVa - MEDICAL VACUUM SYSTEMS
Pump Model
Number of pumps
Nominal pumpingspeed
Free Air Aspired1
Motor Rating
Plant Length
Plant Width
Plant Height
Notes 1. Flow in litres/minute of Free Air Aspired at 63 kPa (475 mmHg) vacuum ±10%
1283 mm
870 mm
2207 mm
RVMa10.2.0
VGD 10
2
10
126
0.37 kW
RVMa10.2.0
VGD 15
2
15
192
0.55 kW
960 mm
600 mm
1520 mm
RVMa15.2.0
VCB 25
2
22.5
312
0.75 kW
RVMa50.2.0
VC 50
2
50
632
1.25 kW
RVMa75.2.0
VC 75
2
75
886
1.85 kW
RVMa100.2.0
VC 100
2
100
1246
3.0 kW
RVMa150.2.0
VC 150
2
150
1870
4.0 kW
RVMa200.2.0
VC 200
2
200
2496
5.5 kW
RVMa300.2.0
VC 300
2
300
3744
7.5 kW
RMVa Duplex Vacuum System for 400V 3 ph 50 Hz Supply
Pump Model
Number of pumps
Nominal pumpingspeed
Free Air Aspired1
Motor Rating
Plant Length
Plant Width
Plant Height
Notes 1. Flow in litres/minute of Free Air Aspired at 63 kPa (475 mmHg) vacuum ±10%
1283 mm
870 mm
2207 mm
RVMa10.3.0
VGD 10
3
10
126
0.37 kW
RVMa10.3.0
VGD 15
3
15
192
0.55 kW
960 mm
600 mm
1520 mm
RVMa15.3.0
VCB 25
3
22.5
312
0.75 kW
RVMa50.3.0
VC 50
3
50
632
1.25 kW
RVMa75.3.0
VC 75
3
75
886
1.85 kW
RVMa100.3.0
VC 100
3
100
1246
3.0 kW
RVMa150.3.0
VC 150
3
150
1870
4.0 kW
RVMa200.3.0
VC 200
3
200
2496
5.5 kW
RVMa300.3.0
VC 300
3
300
3744
7.5 kW
RMVa Triplex Vacuum System for 400V 3 ph 50 Hz Supply
� Compliant to EN ISO 7396-1 2007, HTM 02-01 and HTM 2022.
� U.S. NFPA 99 compliant versions available on request.
� Vacuum pumps are Elmo Rietschle V-Series, oil lubricated rotary vane with wear-free aluminium vanes.
� Up to six vacuum pumps, in two stacks, can be controlled by one master control panel.
� Fully automatic operation with manual over-ride.
� Bacterial filters and vacuum receivers available as options.
Elmo Rietschle is a brand of theGardner Denver Blower Division
AGSS SYSTEM (Anaesthetic Gas Scavenging System)
AGSS Plant Anaesthetic Gas Scavenging System Plant, is available in simplex or duplex, configurations, and offer floor or wall mounting options. Weather proof enclosures is available as standard allowing the plant to be located outside. Remote control and alarm output are fitted as standard.
The AGSS Plant consists of a Simplex (Duty only) or Duplex (Duty and Standby) side channel exhauster, with a motor directly mounted and close coupled. The exhauster impeller does not come into contact with the pump housing giving a long product life, and very low maintenance.
The unit is driven by either a single or three phase electric motor. Voltage and frequency variants can be accommodated on request.
The plant size is determined by the number of terminal units the plant is servicing.
The AGSS Plant consists of the exhauster(s), electrical starter, vacuum regulating valve, exhaust flexible connections and condensation trap which is provided with all interconnecting pipework and wiring. The operating and indicating system, includes the facility to connect remote controllers in each operating department. Alarm relay contacts are fitted as standard on all models.
The plant is provided with a regulation valve installed on the plant, upstream of the exhausters to ensure the system performs safely and efficiently, and within the parameter specified.
DUPLEX AGSS PLANT
Duplex AGSS Plant
Important Notice:- - Pictorial, performance and dimensional data is subject to change without notice.
Flow LPM 260 520 1040 1430 1820 2500 3770
Duplex AGSS plants comprises of two die cast aluminum side channel blowers complete with electrical controls, pressure sensor, relief valve and drain flasks, all pre-piped, pre-wired and factory tested.
The duplex plant control panel incorporates a duty pump selector and indicators to identify the plant status. The standby pump is activated automatically upon high demand or the failure of the duty pump.
Duplex unit incorporates non-return valves to enable the maintenance of one pump whilst the other pump is in service.
Pumps are available to suit single phase or three phase electrical supplies.
Remote switches are available to enable control of the AGSS plant from within the department served and to indicate the status of the plant. Relay contacts to allow monitoring of plant by BMS system can be supplies if required.
Designed to meet the requirements of:-➠ HTM 2022 Medical Gas Pipeline Systems.➠ BS 6834 Active anaesthetic gas scavenging systems.
SIMPLEX AGSS PLANT
➠ Robust Side Channel Vacuum Pump
➠ Flexible connection on both inlet and exhaust (optional).
➠ Anti vibration mounts on motor / pump units.
➠ Robust floor / wall mounting framework .
➠ Pre-set vacuum relief valve.
➠ Plant controls offer full indicating system.
➠ Alarm and BSM output and remote wiring connection.
➠ All plants are tested and certified prior to dispatch.
➠ Each plant is covered by a full warranty.
Simplex AGSS Plant
Important Notice:- - Pictorial, performance and dimensional data is subject to change without notice.
Flow LPM 260 520 1040 1430 1820 2500 3770
Recommended