View
12
Download
0
Category
Preview:
Citation preview
TM®Liebert GXT4 , 5kVA - 10kVAIntelligent, Reliable UPS Protection
Emerson Network Power, a business of Emerson, a global company that leads by applying a unique combination of industry expertise, technology, and resources to make the future of our customers' enterprises and networks possible.
Emerson Network Power's broad technology base and global expertise support a full spectrum of enterprise wide solution for today's business needs . We have been providing tailored solutions for protecting the operation of critical electronic systems in virtually every business segment right from customer premise equipment to global network .
Supported by our right combination of knowledge, experience, product selection and service capability.We are the true solution provider of our customer�s IT infrastructure, right from grid to chip level.
When the stakes are high, partner with Emerson Network Power to optimize your technology with �high-nines� reliability solutions specific to your infrastructure.
Emerson.Consider It Solved.
Customers call on Emerson whenthe stakes are the highest. Why?Because they know that we bringthem technology and engineeringto create solutions for their success.Whatever their challenge, they know that with Emerson by their side, they can �Consider It Solved.�
.
We are Emerson
Today�s converged networks require increased availability and reliability. IT professionals require higher density power protection systems that adapt to mixed load voltages and plug types, while remaining easy to install and maintain.
The Liebert GXT4, a true on-line double conversion ®
UPS system is available in larger capacity models of 5kVA - 10kVA, and features integrated maintenance bypass, as well as optional extended battery runtime. Plus, Liebert Services and protects your UPS. The Liebert GXT4 UPS is designed for use in either rack or tower con�gurations.
As global leader, 220V, 230V and 240V 50/60 Hz models are offered with CE and C-tick markings.
Best Protection for Critical Network Applications
Ef�cient, CompactDesign
Flexible Con�gurationsand Design
Intuitive, IntelligentOperation
Designed Easy Serviceand Warranty
Flexible Monitoring &Management Options
Optimized Operational ExpensesHigh ef�ciency up to 97%ENERGY STAR Certi�ed
Multiple Battery and distribution options
Intuitive color LCD Interface Multiple con�guration options.standard web cards.
Hot -swappable Battery con�guration Liebert Service provides ultimate peace of mind
Monitoring and Shutdown software add �exibility to each installation
The Liebert Solution The Liebert GXT4 UPS meets the need for higher power ®
capacities in small spaces.
The Protection You Need from Damaging power problems
Always Protected !
Pure Sine-Wave
Outages Sags Surges Spikes Noise
Transient FrequencyDeviation
Under-Voltage
Over-Voltage
Harmonics
On line, Double Conversion UPS For Best in Protection
DynamicBypass
UtilitySurge
Suppression
Power FactorCorrection/Recti�er
ChargerInverter Load
Battery
Energy Ef�cient Design
Liebert GXT4 UPS offers a variety of communication options to provide the monitoring and control capabilities demanded by today�s network computing systems.
Libert IntelliSlot Web Vard provides SNMP ®
(including SNMPv3) and IPv.6 and web-based management of your UPS
Built-in USB communications for use TMwithLibert Multilink Automated System
Shutdown Software
TMLiebert Nform Monitoring Software
Libert Universal Monitor And Remote Power Monitor Panels
Libert SiteScan®
TMTrellis Platform
Third-Party Monitoring Systems
Built-in contact closure signals. Provides dry contact communications to remotely monitor UPS operating modes.
Operation can be monitored using:
Liebert IntelliSlot Webcard provides SNMP and web-based management
Active ECO mode keeps the recti�er and inverter operating, allowing the inverter to remainsynchronized to bypass.
This synchronization allows the transfer of the connected equipment to UPSinverter power almost seamlessly if bypass power falls outside the user-set limits.
Once bypass powerreturns within the acceptable parameters, the UPS will return to Active ECO Mode operation
Active ECO mode provides best in class ef�ciency up to 97% without compromise
ENERGY STAR certi�ed UPS modelsUPS products meeting the EPA�s requirements use an average of 35% less energy than their standards counterparts.
Flexible Con�guration Flexible Monitoring & Management Options
Wider input voltage window Features a wide input voltage window that allows the UPS to support the critical load without having to transfer to battery, extending battery life for when it is truly needed
Rack/tower con�guration The versatile unit installs in either con�guration, and includes a rotating color LCD display.
Replaceable hot-swappable internalbatteries Provide 4-9 minutes of runtime at full load depending on the model.
Additional runtime with additionalbattery cabinets Up to 6 external battery cabinets. UPS cabinet includes rear panel plug-and-play connections for optional battery cabinets. 5kVA and 6kVA: 3U, 10kVA: 4U
Internal automatic and manualbypass Assures continuity of power tocritical loads during system maintenanceor in case of internal fault.
Automatic frequency detectionDetects and matches line input frequencies of either 60 or 50 Hz and can also be programmed to convert from one to the other.
Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.
Arrays of accessories bundled with standard model ( such as Rail kit , IS-webcard etc. ), helps to save capital expense .
DynamicBypass
UtilitySurge
Suppression LoadPower Factor
Correction/Recti�erCharger
Inverter
Battery
The Liebert GXT4 true on-line, high power density UPS systems which provide clean power ideal for business critical applications wherein battery backup power is needed to protect network closets or small data centers against costly downtimes.
For installation �exibility, the Liebert GXT4 UPS 5 and 6kVA models allow you to choose from several different wiring con�gurations made possible by the use of removable power distribution boxes (PODs) that simply plug into the rear of the UPS. The standards box provides terminal blocks for hardwired input and output connections. An optional hardwire version that includes a maintenance bypass is also availble
Adaptable Design
5 and 6kVA Models Offer True On-Line Power In A Convenient Rack Con�guration
10kVA Model Provide Even More Power
® TMThe Liebert GXT4 10kVA units offer a �exible solution for protecting rack-mount equipment, including VoIP and PoE
Speci�cally designed for use with the new generation of high power switches, these compact UPS systems pack 10kVA (9kW) of power into a 6U rack/tower package with �exible output voltage and optional power output distribution. The UPS includes built-in user replaceable batteries that can deliver up to 4 minutes at full load runtime and optional external battery cabinets to provide maximum �exibility in adding battery runtimes.
The UPS has output power factor 0.9. That is, 10kVA model provides9kW output power. The unit features integrated internal manualand automatic maintenance bypass and auto detection of extended battery cabinets.
The standard 10kVA model includes terminal blocks for hardwired connections of both input and output. The bundled power distribution module provides 4x IEC-C19 receptacles for bladeservers or high-end networking switches and 4 x IEC C13 receptacles.
Adaptable Design
Liebert GXT4 UPS 10kVA units feature three bays for one power modules and two battery modules. The chassis contains a bypass switch that allows all modules to be removed without powering down the connected load.
Hot - Swappable OperationPOD con�guration with UPS
POWERSOURCE POD
LOADEQUIPMENT
UPS
Removable Maintenance Bypass and Power Distribution Box
10 kVA Models
For 5/6 kVA For 10 kVA
While today�s smaller, rack-based UPS system offer relatively trouble-free operation, the growing criticality of the systems they support has increased the cost of downtime. As a result, the need to maintain these smaller UPS systems is increasingly important.
Extended WarrantyChoose additional of 1-yr or 3-yr warranty on top of the 2-yr standard warranty for worry-free maintenance and total peace of mind.
Start-upOn-site system startup by a certi�ed Emerson Network Power Customer Engineer to assure con�dence that the equipment is up and running at optimum performance
Preventive maintenanceone or two times visits per year by an Emerson Network Power Customer Engineer for higher reliability and availability
On-site serviceShould you experience a problem, we will dispatch a certi�ed Emerson Network Power Customer Engineer to repair or replace, your equipment. Response guaranteed.
LiebertInstelliSlot Port
Terminal Block Communication
REPO
USB Port
C19 Output PowerReceptacles
External BatteryConnector
IT Power system Access Cover
Input CircuitBreaker
Knockoutsfor Hard-wiredPower Input
Output Circuit Breakers
MaintenanceBypass Breker
Output CircuitBreaker
C13 Output Receptacles
D89 Ports (Parallel Communication)
USB Port
C19 Output Receptacles
Output Circuit Breakers
External BatteryConnectorLiebert IntelliSlotPort
Terminal BlockCommunication
MaintenanceBypass Breaker
Output CircuitBreaker
C13 OutputReceptacles
Input CircuitBreaker
Output Circuit Breaker
Knockoutsfor Hard-wiredPower Input IT Power System
Access Cover
Rear View 5-6kVA Rear View 10kVA
Our Extended Service packagesoffer you complete peace of mind
BatteryIndicator
InverterIndicator
FaultIndicator
LCD Panel
ESC Button
BypassIndicator
ECO mode indicator
ENTER button
UP button Down button
Intuitive and intelligent Operation
GXT4-UPS 5kVA
O/P : 230V 50Hz 21.7A I/P : 230V 50Hz 17.3ABATT :100% 9MINSLOAD: 0%
Battery Run-time Chart
Model Number
Used with UPS Model GXT4-5000RT230; GXT4-6000RT230; GXT4-10000RT230Dimensions, W x D x H, mm(in)Unit (with bezel) 430 x 581 x 173 (16.9 x 22.9 x 6.8)Weight, kg (lb)Unit 65 (143.3)Battery ParametersType Valve-regulated, non-spillable, lead acidQuantity x V 1 x 20 x 12V
Operating Temp, °C (°F) 0 to 40 (32 to 104)Storage Temp, °C (°F)Relative HumidityOperating Elevation
-15 to 50 (5 to 122)0-95% non-condensingUp to 1000m (3280.83 ft.) at 25°C (77°F)
AgencySafety IEC62040-1:2008 versionTransportation ISTA Procedure 1E
Load (%)
Internal Battery
10
20
30
40
50
60
70
80
90
100
105
52
40
27
21
17
14
12
10
9
97
47
33
22
17
14
11
9
8
6
98
42
25
17
12
9
7
6
5
4
5kVA 6kVA 10kVA
Load (%)
10
20
30
40
50
60
70
80
90
100
211
140
102
76
53
48
43
38
32
27
194
122
83
62
48
42
35
28
25
22
165
99
53
42
31
25
20
17
14
12
5kVA 6kVA 10kVA Load (%)
10
20
30
40
50
60
70
80
90
100
427
220
154
130
105
91
74
64
51
48
341
185
140
108
91
72
53
49
45
41
311
144
99
68
49
42
35
28
25
21
5kVA 6kVA 10kVA Load (%) 5kVA 6kVA 10kVA
Load (%) 5kVA 6kVA 10kVA Load (%) 5kVA 6kVA 10kVA Load (%) 5kVA 6kVA 10kVA
Environmental
GXT4-240VBATT
Internal Battery +1 External Battery Cabinet Internal Battery +2 External Battery Cabinet Internal Battery +3 External Battery Cabinet
10
20
30
40
50
60
70
80
90
100
441
326
204
160
143
126
107
97
81
73
429
303
167
146
126
105
92
76
66
53
344
166
133
99
74
53
48
42
42
31
Internal Battery +4 External Battery Cabinet Internal Battery +5 External Battery Cabinet Internal Battery +6 External Battery Cabinet
10
20
30
40
50
60
70
80
90
100
480
428
312
209
164
151
138
124
108
100
463
338
227
166
150
134
113
103
92
78
436
213
153
127
99
77
64
51
47
42
10
20
30
40
50
60
70
80
90
100
480
436
339
304
203
166
155
145
134
123
464
422
318
208
165
153
140
127
110
101
449
312
166
144
123
100
80
69
53
49
10
20
30
40
50
60
70
80
90
100
480
457
428
327
285
207
167
158
149
140
480
445
339
304
206
165
154
143
133
122
459
330
202
157
138
120
100
81
72
63
* Battery run time measured in minutes
External Battery Speci�cation
ACP-GXT4-1-1-15-1
Emerson Network Power Asia Pacific
AustraliaT: 1800-065345F: 61-2-97438737
IndonesiaT: 62-21-2513003F: 62-21-2510622
JapanT: 81-3-54038594F: 81-3-54032924
KoreaT: 82-2-34831500F: 82-2-5927883
MalaysiaT: 603-78845000F: 603-78845188
New ZealandT: 64-3-3392060F: 64-3-3392063
PakistanT: 92-42-36622526 to 28F: 92-42-36622530
PhilippinesT: 63-2-7207400F: 63-2-6203693
SingaporeT: 65-64672211F: 65-64670130
ThailandT: 66-2-6178260F: 66-2-6178277 to 78
VietnamT: 84-4-37628908F: 84-4-37628909
IndiaT: 91-22-33154400F: 91-22-25828358
ChinaT: 86-755-86010808F: 86-755-86010909
Emerson Among Top 50 On Fortune Survey Of “Worlds Most Admired” Companies
Scan to learn more about Liebert GXT4 or go to www.emersonnetworkpower.com
® �
While every precaution has been taken to ensure accuracy and completeness in this brochure. Emerson Network Power assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
Subscribe to EmersonConnect with us on:
Liebert GXT4 Technical Speci�cations - 5, 6 and 10 kVA models
User-Con�gurable
Storage Temp
Operating Elevation
Audible Nosie
Operating Temp
Waveform
Output AC
Environment Parameters
Rating
GXT4-5000RT230
Nominal Operating Frequency
Frequency
GXT4-6000RT230 GXT4-10000RT230Parameters
Input AC
50 or 60Hz (Factory Default is 50Hz)
200/208/220/230/240VAC
50HZ or 60Hz, Nominal
Sinewave
Recharge Time
Battery
Type
Qty x V x Rating
Valve-regulated, nonspillable, lead acid
20 x 12V
3 hours to 90% capacity after full discharge into 100% load
5000VA/4000W 6000VA/4800W 10000VA/9000W
0°C to +40°C (+32°F to 104°F)
-15°C to +50°C (5°F to 122°F)
Up to 1000m (3281 ft.) at 25°C (77°F) without derating
Operating Voltage Range 176 - 280VAC
Input Frequency Opertion 40-70Hz
Less than 55 dBA at 1 meter from the rear <50 dBA,at 1 meter from the front or sides
0% to 95%, non-condensingRelative Humidity
Safety
Agency
ESD
EMI/EMC/C-Tick EMC
IEC62040-1:2008 version, GS mark
IEC 62040-2 2nd Ed
IEC/EN EN61000-4-2, Level 4, Criteria A
Electrical Fast Transient
Radiated Susceptibility IEC/EN EN61000-4-2, Level 3, Criteria A
Weight(lb)(kg)
Dimension (H x W x D)(in)
Mechanical Parameters
430 x 574 x 217 (16.9 x 22.4 x 8.5)
132.2 (60)
Main Mode Overload >200% for 5 cycles; 151-200% for 1 seconds; 121-150% 10seconds;105-130% 1 minute
Transportation
Surge Immunity
IEC/EN EN61000-4-2, Level 2, Criteria A
IEC/EN EN61000-4-2, Level 1, Criteria A
ISTA Procedure 1E
430 x 581 x 261 (16.9 x 22.9 x 10.3)
154.3 (70)
Power distribution speci�cations
Input Power Connection
Output Power ConnectionIncludes(Manual Bypass Switch With Indicator Lamps)
Amp Rating 32 Amps2Single-phase (L-N-G) hardwire, 6-10mm (8-10AWG)2Single-phase (L-N-G) hardwire, 6-10mm (8-10AWG)
Two IEC 320 C19 16A/250V SocketsSix C13 10A/250V Sockets
32AInput Branch Circuit Breaker Supplied by User
Model Number PD2-CE6HDWRRMBS PD2-CE10HDWRMBS
Four IEC 320 C19 16A/250V SocketsFour C13 10A/250V Sockets
63A
VAC(Factory Default ) 230VAC
63A
Recommended