View
223
Download
0
Category
Preview:
Citation preview
Compact Busbar Distribution System800...6300 A
Plug-in Busbar Distribution System160...800A
Small Power Plug-in Busbar Distribution System100-160-225A
Plug-in Busbar Distribution System40-63A
Multi-Conductor Lighting Busbar System25-32-40A
Lighting Busbar System25-32-40A
Multi Conductor Trolley Busbar System35...250A
Underfloor Ducting Systems
Raised Floor Energy Distribution Systems25...63A
CableTray Systems
E-LINE KB
E-LINE KO
E-LINE MK
E-LINE KAP
E-LINE DL
E-LINE KAM
E-LINE TB
E-LINE DK
E-LINE DKY
E-LINE UK
Compact Busbar Distribution System630...6300 A
E-LINE KX
www.eae.com.tr
EAE Elektrik A.Ş.Akcaburgaz Mahallesi,
119. Sokak, No:10 34510Esenyurt-Istanbul-TURKEY
Tel: +90 (212) 866 20 00Fax: +90 (212) 886 24 20
T E
ME 04
IEC 60439-2 sISO 9001
14001
NTAL E MM AN NO AR GI EV MNE E ND TN SA YY STI TL EA M
U SQ
Catalogue 06-Eng. / Rev 07 500 Pcs. ATA LTD. / A.C.E./ www.atamatbaa.net
EAE has full right to make any revisions or changes on this catalogue without any prior notice.
23/01/2013
General Description
Order Code System
Technical Characteristics
KAM Standard Busbars
KAM Standard Elements
KAM Tap Off Plugs
KAP Standard Busbars
KAP Standard Elements
KAP Tap Off Plugs
Fixing and IP Accessories
Certificate
EC Declaration Of Conformitys
Product Overview
E-LINE KAM/KAP
2-3
4
5
6
7
8
9
10
11
12-13
14
15
16
E L E K T R İ K
CONTENTS
E KAM/KAPLINE
3000750
0 0 0 0
750 750375 375
L1
L2
L3
N
2
KAM and KAP are busbar trunking systems, for
lighting (KAM) and small Power (KAP), designed and
certified in full compliance with international
standards IEC 60439-1 and 2 and IEC 60529. Both
systems have been tested and certified at the CESI
Institute in accordance with the full type test cycle
stated in the relevant IEC codes.
KAM and KAP Busbar Systems
General Description
General Characteristics
The housing is manufactured using pregalvanised
sheet steel metal which provides a substantial earth
path. The housing gives the line a very high
mechanical strength, particularly suitable for
industrial applications and applications in severe
climatic conditions. The conductors are in
electrolytic copper, tin plated and insulated along
their full length (except at tap off positions) with a self
extinguishing plastic sleeve. 2 and 4 conductor
versions are standard ,with 3 or 5 conductor versions
supplied upon request. Each 3 m standard straight
length is provided with 4 tap off points at 75 cm
distance on one side of the trunking.
Feed units are available for installing at either end of
the system or as a centre feed unit. The feed units are IP55 as standard, and will accept
supply cables up to ø16mm. The feed units are supplied complete with end closure and joint cover.
Feed Units
The joint is a fast locking type with a single screw.
The joint contacts are silver plated and highly
oversized in comparison with the nominal current
towithstand in total safety possible short term
current peaks. The joint is further reinforced with
tightening springs which ensure the correct contact
pressure between the conductors. The joint
provides continuity of the housing when used as the
earth conductor.
Joint
E L E K T R İ K
3
Tap off plugs are available in ratings from 10A to 32A. The plugs are manufactured in a
self extinguishing material. The contacts for the phase and neutral conductors are
silver plated copper to provide the best conductivity and resistance to corrosion. The
tap off plugs for the KAM and KAP busbar systems have different plug-in
configurations and are not interchangeable. All plugs are equipped with a separate
earth contact which is the first to make and and the last to break. The plugs have been
tested at CESI Laboratories for 50 connection disconnection duty cycles. The tap off
plugs when plugged into the system provides both a good contact with the main
conductors and a secure fixing of the plug on the housing.
KAM 10B are single phase plugs, with fixed phase, without fuses, prewired with cable,
cross section 3x1.5 mm² and length 1m. They can be supplied with different length
cable on request.
KAM 16 K and KAP 16 K are single phase plugs with fixed phase, available with or
without fuse holders. A three phase version is also available, and can be used as a
phase selectable unit for single phase operations. They can be wired with cables up to
a maximum of Ø11 mm.
KAP 32 is a three-phase tap off box, available with fuse holder or with DIN rail to accept
standard modular MCB's.
10A Tap Off Plugs (Only for KAM)
16A Tap Off Plugs
Tap Off Plugs
32A Tap Off Box (Only For KAP)
Standard Length
Special Length
Flexible Elbow
Feed Box
End Feed Box
Central Feed Box
002 B --
IP 55 0
KAM T DSS
CodeNumber of
Conductors
2
3
4
5
Conductor Configuration
Configuration
L2, N, PE(Housing)
L2, N, PE+Housing
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
2 wire
3 wire
4 wire
5 wire
Busbar Code
KAM
KAP
02
03
04
06
25A
32A
40A
63A
STD
X
FD
BB
BS
BO
4
E L E K T R İ K
E KAM/KAPLINE
5
Busbar Type
BusbarRated Current
BusbarCode
Protection Degree UNPAINTEDPAINTED
-B
Order Code SystemBUSBAR TYPEBUSBAR CODEPROTECTION DEGREECONDUCTOR CONFIGURATIONUNPAINTED / PAINTEDCOMPONENT
Components
V
Hz
kA
kA
kA
m / m
m / m
m / m
m / m
m / m
m / m
W / m
mm
mm
mm
kg/m
kg/m
rms
20
L
R
X
Z
R
X
Z
2
0
0
0
2
2
KAM 02 KAM 03 KAP 04 KAP 06
W
W
W
W
W
W
IEC 60439 1-2
690
50/60
IP 55
5
2.27
21
5.31
1.37
5.49
8.58
1.53
8.69
3.23
3.20
18.30
3.20
1.13
1.17
6
2.72
21
4.67
1.11
4.80
7.60
1.22
7.69
4.66
4.00
18.30
4.00
1.17
1.19
7.5
3.4
21
1.70
0.69
1.84
3.48
0.90
3.59
2.68
6.00
18.30
6.00
1.33
1.41
9
4
21
1.45
0.14
1.45
3.22
0.49
3.26
5.68
12.50
18.30
6.00
1.42
1.48
A 25 32 40 63
690 690 690
E L E K T R İ K
E KAM/KAPLINETechnical Characteristics
Rated Current
Standards
Rated Insulation Voltage
Rated Frequency
Protection Degree
Short-Circuit (Peak)
Short-Circuit (1 sec)
Short Circuit(Peak)Tested 1 msec.
Resistance
Reactance
Impedance
Fault Resistance
Fault Reactance
Fault Impedance
Joule Losses At In
L1, L2, L3, N (Cross Section)
PE (Housing)
PE (Conductor)
Weight (4 Conductors)
Weight (5 Conductors)
Voltage Drop Calculation
U=
U=
I.2L (R.cos
3.I.L (R.cos
V
V
).10
).10
-3
-3
+X.sinj
+X.sinj
The maximum permitted load for the support of light fittings of the system is 15 kg. concentrated or
20 kg. distributed for a recommended support span of every 2 metres without any deformation of
the housing.
For three phase ;
D
D
j
j
U =
I =
L =
R =
X = Reactance
m
m
m
m
W
W
D V
A
mt
Ö
Generally Voltage drop of a busbar system can be calculated with the following formula.
For single phase;
Voltage Drop
Rated Current
Length of Line
Resistance
5
E KAMLINE 25/32
N
L3
L2
L1
35
55
3025050
3025046
3025029
3025027
3025058
3025054
3025033
3025031
5
4
3
2
5
4
3
2
25
32
3000750
0 0 0 0
750 750375 375
E L E K T R İ K
6
Standard Elements
Standard Busbars
Phase Order CodeConductorsCurrent (A) Desc r ip t i on
L1, L2, L3, N, (PE+Housing)
L1, L2, L3, N, (+Housing)
L2, N, (PE+Housing)
L2, N, (+Housing)
L1, L2, L3, N, (+Housing)
L2, N, (PE+Housing)
L2, N, (+Housing)
L1, L2, L3, N, (PE+Housing)
KAM 0205
KAM 0204 Standard Busbar
KAM 0203 Standard Busbar
KAM 0202 Standard Busbar
Standard Busbar
KAM 0305 Standard Busbar
KAM 0304 Standard Busbar
KAM 0303 Standard Busbar
KAM 0302 Standard Busbar
*Special straight length busbars are manufactured as standard as 1 m., 1,5 m. and 2 m.
E KAMLINE 25/32
75
10
8
200 60160
M25
10
8
200 75 60
M25
160
3024415
3024417
3025072
3025070
3025068
3025066
3025064
3025062
KAM 0205KAM 0204KAM 0203KAM 0202
KAM 0205KAM 0204KAM 0203KAM 0202
KAM 0205KAM 0204KAM 0203KAM 0202
KAM 0205KAM 0204KAM 0203KAM 0202
KAM 0305KAM 0304KAM 0303KAM 0302
KAM 0305KAM 0304KAM 0303KAM 0302
KAM 0305KAM 0304KAM 0303KAM 0302
KAM 0305KAM 0304KAM 0303KAM 0302
32
32
32
32
25
25
25
25
E L E K T R İ K
7
565
16
5
70
Feed Box*
Busbars Order Code
KAM 0305 BBFeed Box
KAM 0205 BBFeed Box
Current (A) Desc r ip t i on
Standard Elements
Feed Box
End Feed Box*
KAM 0305 BSEnd Feed Box
KAM 0205 BSEnd Feed Box
Busbars Order CodeCurrent (A) Desc r ip t i on
End Feed Box
Central Feed Box*
KAM 0305 BOCentral Feed Box
KAM 0205 BOCentral Feed Box
Busbars Order CodeCurrent (A) Desc r ip t i on
Central Feed Box
* With PE Conductor and M25 Gland as standard. End Closer is supplied together with the feed unit.
Flexible Elbow
KAM 0305-FDFlexible Elbow
KAM 0205-FDFlexible Elbow
Busbars Order CodeCurrent (A) Desc r ip t i on
Flexible Elbow
48
40
KAM 16 FSKAM 16 K
3024549
3024548
3024547
L1, N, PE
L2, N, PE
L3, N, PE
3024612
3024611
3024610
3024609
3024616
3024615
3024614
3024613
-
-
-
-
-
-
-
L1, N, PE
L2, N, PE
L3, N, PE
L1, L2, L3, N, PE
L1, N, PE
L2, N, PE
L3, N, PE
L1, L2, L3, N, PE
4022
10
16
16
E L E K T R İ K
8
E KAMLINE 25/32
66
105
68
74
KAM 10 B
KAM 16 - FS L1
KAM 16 - FS Tap Off Plug L2
KAM 16 - FS Tap Off Plug L3
KAM 16 - FS Tap Off Plug L123
Tap Off Plug
KAM 16 - K L1
KAM 16 - K Tap Off Plug L2
KAM 16 - K Tap Off Plug L3
KAM 16 - K Tap Off Plug L123
Tap Off Plug
Tap Off Plugs
Order CodeCurrent (A) Phase PropertiesDesc r ip t i on Cable Length
Tap Off Plugs
Tap Off Plugs
Order Code
* Plugs with different length cable available upon request.
KAM 10 - B L1*
KAM 10 - B Tap Off Plug L2*
KAM 10 - B Tap Off Plug L3*
Tap Off Plug
Current (A) Phase PropertiesDesc r ip t i on
1 m. TTR Cable
1 m. TTR Cable
1 m. TTR Cable
Cable Length
With Black Cover
With Yellow Cover
With Blue Cover
Without Fuses.Max diameterof feeder cableis ø11mm.
With 5x20 fuseholders. Maxdiameter of feedercable is ø11mm.
3025080
3025078
3025082
3025084
3025076
3025074
3025086
3025088
5
4
3
2
5
4
3
2
40
63
N
L1
L2
L3
35
55
3000750
0 0 0 0
750 750375 375
E L E K T R İ K
9
E KAPLINE 40/63
Standard Busbars
Current (A) Conductors PhaseDesc r ip t i on
L1, L2, L3, N, (+Housing)
L2, N, (PE+Housing)
L2, N, (+Housing)
L1, L2, L3, N, (PE+Housing)
L1, L2, L3, N, (PE+Housing)
L1, L2, L3, N, (+Housing)
L2, N, (PE+Housing)
L2, N, (+Housing)
KAP 0605 Standard Busbar
KAP 0604 Standard Busbar
KAP 0603 Standard Busbar
KAP 0602 Standard Busbar
KAP 0405 Standard Busbar
KAP 0404 Standard Busbar
KAP 0403 Standard Busbar
KAP 0402 Standard Busbar
Order Code
Standard Elements
10
8
200 60160
M32
10
8
200 75 60
M32
160
63
63
63
63
40
40
40
40
3025100
3025098
KAP 0405KAP 0404KAP 0403KAP 0402
KAP 0405KAP 0404KAP 0403KAP 0402
KAP 0405KAP 0404KAP 0403KAP 0402
KAP 0405KAP 0404KAP 0403KAP 0402
KAP 0605KAP 0604KAP 0603KAP 0602
KAP 0605KAP 0604KAP 0603KAP 0602
KAP 0605KAP 0604KAP 0603KAP 0602
KAP 0605KAP 0604KAP 0603KAP 0602
3025104
3025102
3024962
3024411
3024960
3024413
75
E L E K T R İ K
10
E KAPLINE 40/63
565
16
5
70
KAP 0605 BBFeed Box
KAP 0405 BBFeed Box
Feed Box*
Feed Box
Busbars Order CodeCurrent (A) Desc r ip t i on
Standard Elements
KAP 0605 BSEnd Feed Box
KAP 0405 BSEnd Feed Box
End Feed Box*
End Feed Box
Busbars Order CodeCurrent (A) Desc r ip t i on
Central Feed BoxKAP 0605 BO
Central Feed BoxKAP 0405 BO
Central Feed Box*
Central Feed Box
Busbars Order CodeCurrent (A) Desc r ip t i on
* With PE Conductor and Special EAE Gland M32 as standard.
KAP 0605-FDFlexible Elbow
KAP 0405-FDFlexible Elbow
Flexible Elbow
Busbars Order CodeCurrent (A) Desc r ip t i on
Flexible Elbow
228
11
3
228
11
3
KAP 32
KAP 32 FS
3024556
3024555
3024554
3024557
3024552
3024551
3024550
3024553
3025109
3025108
L1, N, PE
L2, N, PE
L3, N, PE
L1, L2, L3, N, PE
L1, N, PE
L2, N, PE
L3, N, PE
L1, L2, L3, N, PE
L1, L2, L3, N, PE
L1, L2, L3, N, PE
12590
92
53
16
16
32
E L E K T R İ K
11
E KAPLINE 40/63
48
40
66
105
KAP 16 FSKAP 16 K
Tap Off Plugs
Tap Off Plugs
Tap Off Plugs
KAP 16 - FS L1
KAP 16 - FS Tap Off Plug L2
KAP 16 - FS Tap Off Plug L3
KAP 16 - FS Tap Off Plug L123
Tap Off Plug
KAP 16 - K L1
KAP 16 - K Tap Off Plug L2
KAP 16 - K Tap Off Plug L3
KAP 16 - K Tap Off Plug L123
Tap Off Plug
* Tap off box can be fitted with MCB's of different ratings and brands.
Order CodeCurrent (A) Phase PropertiesDesc r ip t i on
KAP 32-Empty Tap Off Box*
KAP 32-Tap Off Box 10x38 fuse holders
10 x 38 Fuse holdersMax diameter of feedercable is ø 20 mm.
Order CodeCurrent (A) Phase PropertiesDesc r ip t i on
Without FusesMax diameter of feedercable is ø 11 mm.
5 x 20 Fuse holders.Max diameter of feedercable is ø 11 mm.
Order Code
1004874KA - TP Lighting fixture fixing unit
Desc r ip t i on
Order Code
1004283KA-TPL Fixing unit “L” type
Desc r ip t i on
Order Code
1004190
Desc r ip t i on
KA - TP
80
3037
ø 7,5
KA - TPL
95
3540
ø 9
ø 12
1
2 3
E L E K T R İ K
12
E KAM/KAPLINEFixing and IP Accessories
Fixing and IP Accessories
To Ceiling
To Floor
To Wall
KAM - KAP Fixing Unit
Fixing and IP Accessories
Fixing and IP Accessories
3025106KA-TD Side Wall Support
3025158KA - TPU TPU Fixing unit “U” type
3025160KAM-KAP Mechanical Joint Support
56
15
17115
ø 7
ø 8
ø 7
KA - TPU
55
4020
ø 7,5
60
25
20
ø 7,5
E L E K T R İ K
13
E KAM/KAPLINEFixing and IP Accessories
Order CodeDesc r ip t i on
Order CodeDesc r ip t i on
Order CodeDesc r ip t i on
Side Wall Support
Fixing unit “U” type
Joint Support
KA-TD Side Wall Support
Mechanical Joint Support
15
E KAM/KAPLINE
E L E K T R İ K
E L E K T R İ K
E-Line KAM-KAP Busbar Energy Distribution System
Declaration
EAE Elektrik A.S.
CE DECLARATION OF CONFORMITY
Product Group
Standard :
Manufacturer
IEC 60439-1
IEC 60439-2
EAE Elektrik Asansor End. Insaat San. ve Tic. A.S.
EAE Elektrik Asansor End. Insaat San. ve Tic. A.S.
This is to attest, under our sole responsibility, that the aforementioned products conforms with
the determined regulations,guidelines and the below standards.
Date
31.10.2005
CE - Directive
2006/95/EC “Low Voltage Directive”
Akcaburgaz Mahallesi, 119. Sokak, No:10 34510 Esenyurt-IstanbulTel: +90 (212) 866 20 00 Fax: +90 (212) 886 24 20 www.eae.com.tr
Akcaburgaz Mahallesi, 119. Sokak,No:10 34510 Esenyurt-Istanbul
Type Tests include verification of;
1- Temperature-rise Limits (8.2.1)
2- Dielectric Properties (8.2.2)
3- Short-circuit Strength (8.2.3)
4- The Effectiveness of The Protective
Circuit (8.2.4)
5- Clearances and Creepage Distances (8.2.5)
6- Mechanical Operation (8.2.6)
7- Degree of Protection (8.2.7)
8- The Resistance of Insulating Materials to
Abnormal Heat and Fire (8.2.9)
9- Structural Strength (8.2.10)
10- Crushing Resistance (8.2.12)
11- Resistance of Insulating Materials
to Abnormal Heat (8.2.13)
12- Resistance to Flame Propagation (8.2.14)
13- Fire Resistance in Building
Penetration (8.2.15)
E L E K T R İ K
E L E K T R İ K
E KAM/KAPLINE
25A - 63A PLUG-IN BUSBAR SYSTEMSPRODUCT OVERVIEW
(E-Line KAM / KAP)
1-
2-
3-
4-
5-
6-
7-
8-
9-
10-
11-
12-
13-
The busbar sytem shall have rated current levels between 25A and 63A andshall have copper conductors.
Plug-in busbar system shall have one of the following conductor number andconfigurations;
a) 2 conductors : L1 / N / Housing (Earthing)b) 3 conductors : L1 / N / PE + Housing (PE conductor and housing are connected)c) 4 conductors : L1 / L2 / L3 / N / Housing (Earthing)d) 5 conductors : L1 / L2 / L3 / N / PE + Housing (PE conductor and housing are connected)
Housing shall be used as earth conductor.
The rated insulation voltage of the system shall be 690 V.
On a three meter standard length there shall be four plug-in points.
The conductors in the housing shall be continuously insulated and only the plug-in points to create contact area.
There shall be insulator supports at the plug-in points.
The conductors shall be of electrolytic copper and continuously tin plated.
Each current rating of the busbar system shall have a type test report according toIEC 60439/2. The type test reports shall be from an internationally accepted thirdparty laboratory.
Joints of the busbar shall slide into each other; joint contacts shall be silver plated.To ensure a safe joint contact there shall be springs on both sides of jointcontacts.
IP Protection degree of the busbars shall be 55.
The housing of the busbar shall be manufactured from 0,50 mm thick galvanisedsheet steel.
Contacts of the tap offs shall be off jawed structure, which touches the conductorson both sides. The contacts shall also have springs.
The m
stripped off at
anufacturing facility for the busbar systems shall have ISO 9001 and ISO 14001 certification.
Product Overview
16
Recommended