Initial Transient Power Operation of a Supercritical ... · Initial Transient Power Operation of a...

Preview:

Citation preview

Page 1Supercritical CO2 Power Cycles Symposium March 29-31, 2016

Initial Transient Power Operation of a

Supercritical Carbon Dioxide Brayton Cycle

with Thermal-Hydraulic Control

Eric Clementoni

Timothy Cox

Martha King

Bechtel Marine Propulsion CorporationBettis Atomic Power LaboratoryWest Mifflin, PA

Page 2Supercritical CO2 Power Cycles Symposium March 29-31, 2016

Presentation Summary

• sCO2 Brayton Cycle Integrated Systems Test

(IST) Overview

• System Control

• System Operating Conditions

• Operational Test Results

Page 3Supercritical CO2 Power Cycles Symposium March 29-31, 2016

• 100 kWe IST has been main sCO2 development

focus of BMPC

• Simple Brayton cycle

– Single variable speed turbine-compressor

– Single constant speed turbine-generator

– Single recuperator

• Focus on system control

– Rapid startup

– Power changes

– Shutdown

IST Overview

CompressorTurbine

Heat

Source

Generator Turbine

Recuperator

Precooler

Sea WaterCooling

Water

Page 4Supercritical CO2 Power Cycles Symposium March 29-31, 2016

IST Physical Layout

Hot Oil System

Turbo-Generator

Turbo-Compressor

Recuperator

Precooler

Turbine Throttle Valves

Compressor Recirculation Valve

Leakage Collection Compressors

Page 5Supercritical CO2 Power Cycles Symposium March 29-31, 2016

IST Physical Layout

Turbo-Generator

Recuperator

Precooler

Turbo-Compressor (not

visible)

Page 6Supercritical CO2 Power Cycles Symposium March 29-31, 2016

IST Turbomachinery

Turbo-Generator

Turbo-Compressor

Compressor/Diffuser Turbine

Thrust Bearing

Page 7Supercritical CO2 Power Cycles Symposium March 29-31, 2016

Cycle Control Overview

• Turbine-generator speed fixed (60,000 rpm)

• Power level controlled via turbine-compressor speed

– Speed setpoint via lookup table

• Compressor recirculation valve position also function

of system power level

– More open at low power, nearly closed at max power

– Maintains adequate surge margin

• IHX outlet temperature and compressor inlet

temperature controlled via PI control of heater

power and cooling water flow, respectively

Page 8Supercritical CO2 Power Cycles Symposium March 29-31, 2016

Thermal-Hydraulic Control

IHX

GenMot/

Gen

Pre

coo

ler

Recuperator

Load regulated to

maintain 60,000 rpm

shaft speed

No load

PI control

regulates

TC shaft

speed

TC speed

setpoint

function of

TG load

setpoint

T T C

Page 9Supercritical CO2 Power Cycles Symposium March 29-31, 2016

IST Operating Conditions

• Maximum power limited to 40 kWe by motor-

generator controller performance

• Turbine inlet temperature reduced to 440°F

– Achieve max power with CCV4 nearly closed

• Compressor inlet of 96°F and ~1310 psia

– Stable compressor inlet density for small changes

in parameters

– Fixed total system mass � small changes in

pressure with power level due to cavity conditions

Page 10Supercritical CO2 Power Cycles Symposium March 29-31, 2016

System Power Transients

0

5

10

15

20

25

30

35

40

45

0 1000 2000 3000 4000 5000

TG

Lo

ad

(%

Po

we

r)

Time (seconds)

Generator Output

Load Setpoint

Page 11Supercritical CO2 Power Cycles Symposium March 29-31, 2016

Turbine-Compressor Speed Control

40000

42000

44000

46000

48000

50000

52000

54000

56000

0 1000 2000 3000 4000 5000

Turb

ine

-Co

mp

ress

or

Sp

ee

d (

rpm

)

Time (seconds)

Turbine-Compressor Speed

Speed Setpoint

Page 12Supercritical CO2 Power Cycles Symposium March 29-31, 2016

Compressor Recirculation Valve Response

0

10

20

30

40

50

60

0 1000 2000 3000 4000 5000

Co

mp

ress

or

Re

circ

ula

tio

n V

alv

e P

osi

tio

n (

% O

pe

n)

Time (seconds)

Page 13Supercritical CO2 Power Cycles Symposium March 29-31, 2016

Compressor Recirculation Valve Resistance

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

0 1000 2000 3000 4000 5000

Co

mp

ress

or

Re

circ

ula

tio

n V

alv

e C

v

Time (seconds)

Page 14Supercritical CO2 Power Cycles Symposium March 29-31, 2016

Summary

• IST operated over range of power transients

between 5% and 40% of design rating

• Thermal-hydraulic control strategy works very

well for transients evaluated to date

• Overall system response is very stable despite

large oscillations in compressor recirculation

valve position

Page 15Supercritical CO2 Power Cycles Symposium March 29-31, 2016

Acknowledgements

• This paper summarizes work that has been

performed a number of devoted engineers,

scientists, technicians, and support personnel

at the Bechtel Marine Propulsion Corporation

and our subcontractors. This paper would not

be possible without the efforts of this team.

Recommended