View
221
Download
0
Category
Preview:
Citation preview
© 2008 IBM Corporation
IBM Power Systems
IBM Systems & Technology Group
IBM Power Systems Technical
Excellence03/29/07
2
IBM Power Systems
© 2008 IBM Corporation
REQUIRED CHARTSThe presenter must display the Special Notices chart, the Notes on Benchmarks and Values charts (if the referenced values are given), and the Notes on Performance Estimates chart (if the referenced performance estimates are given) during the course of the presentation. Any printed copies of this presentation that are distributed must include legible copies of these charts. If printed copies are not distributed, the attendees must be offered the option to receive legible printed copies of these charts.TRADEMARKSPlease review the Special Notices page prior to updating this presentation to ensure all trademarks used are given proper attribution.SPEAKER NOTESThis presentation may contain speaker notes available imbedded or as a separate file. Please ensure these are utilized if available.
Revised January 9, 2003
Notes to Presenter
3
IBM Power Systems
© 2008 IBM Corporation
This document was developed for IBM offerings in the United States as of the date of publication. IBM may not make these offerings available in other countries, and the information is subject to change without notice. Consult your local IBM business contact for information on the IBM offerings available in your area.Information in this document concerning non-IBM products was obtained from the suppliers of these products or other public sources. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products.IBM may have patents or pending patent applications covering subject matter in this document. The furnishing of this document does not give you any license to these patents. Send license inquires, in writing, to IBM Director of Licensing, IBM Corporation, New Castle Drive, Armonk, NY 10504-1785 USA. All statements regarding IBM future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only. The information contained in this document has not been submitted to any formal IBM test and is provided "AS IS" with no warranties or guarantees either expressed or implied.All examples cited or described in this document are presented as illustrations of the manner in which some IBM products can be used and the results that may be achieved. Actual environmental costs and performance characteristics will vary depending on individual client configurations and conditions.IBM Global Financing offerings are provided through IBM Credit Corporation in the United States and other IBM subsidiaries and divisions worldwide to qualified commercial and government clients. Rates are based on a client's credit rating, financing terms, offering type, equipment type and options, and may vary by country. Other restrictions may apply. Rates and offerings are subject to change, extension or withdrawal without notice.IBM is not responsible for printing errors in this document that result in pricing or information inaccuracies.All prices shown are IBM's United States suggested list prices and are subject to change without notice; reseller prices may vary.IBM hardware products are manufactured from new parts, or new and serviceable used parts. Regardless, our warranty terms apply.Any performance data contained in this document was determined in a controlled environment. Actual results may vary significantly and are dependent on many factors including system hardware configuration and software design and configuration. Some measurements quoted in this document may have been made on development-level systems. There is no guarantee these measurements will be the same on generally-available systems. Some measurements quoted in this document may have been estimated through extrapolation. Users of this document should verify the applicable data for their specific environment.
Revised September 26, 2006
Special Notices
4
IBM Power Systems
© 2008 IBM Corporation
Revised January 15, 2008
Special Notices (Cont.)
The following terms are registered trademarks of International Business Machines Corporation in the United States and/or other countries: AIX, AIX/L, AIX/L (logo), AIX 6 (logo), alphaWorks, AS/400, BladeCenter, Blue Gene, Blue Lightning, C Set++, CICS, CICS/6000, ClusterProven, CT/2, DataHub, DataJoiner, DB2, DEEP BLUE, developerWorks, DirectTalk, Domino, DYNIX, DYNIX/ptx, e business (logo), e(logo)business, e(logo)server, Enterprise Storage Server, ESCON, FlashCopy, GDDM, i5/OS, i5/OS (logo), IBM, IBM (logo), ibm.com, IBM Business Partner (logo), Informix, IntelliStation, IQ-Link, LANStreamer, LoadLeveler, Lotus, Lotus Notes, Lotusphere, Magstar, MediaStreamer, Micro Channel, MQSeries, Net.Data, Netfinity, NetView, Network Station, Notes, NUMA-Q, OpenPower, Operating System/2, Operating System/400, OS/2, OS/390, OS/400, Parallel Sysplex, PartnerLink, PartnerWorld, Passport Advantage, POWERparallel, Power PC 603, Power PC 604, PowerPC, PowerPC (logo), Predictive Failure Analysis, pSeries, PTX, ptx/ADMIN, Quick Place, Rational, RETAIN, RISC System/6000, RS/6000, RT Personal Computer, S/390, Sametime, Scalable POWERparallel Systems, SecureWay, Sequent, ServerProven, SpaceBall, System/390, The Engines of e-business, THINK, Tivoli, Tivoli (logo), Tivoli Management Environment, Tivoli Ready (logo), TME, TotalStorage, TURBOWAYS, VisualAge, WebSphere, xSeries, z/OS, zSeries.
The following terms are trademarks of International Business Machines Corporation in the United States and/or other countries: Advanced Micro-Partitioning, AIX 5L, AIX PVMe, AS/400e, Calibrated Vectored Cooling, Chiphopper, Chipkill, Cloudscape, DataPower, DB2 OLAP Server, DB2 Universal Database, DFDSM, DFSORT, DS4000, DS6000, DS8000, e- business (logo), e-business on demand, EnergyScale, Enterprise Workload Manager, eServer, Express Middleware, Express Portfolio, Express Servers, Express Servers and Storage, General Purpose File System, GigaProcessor, GPFS, HACMP, HACMP/6000, IBM Systems Director Active Energy Manager, IBM TotalStorage Proven, IBMLink, IMS, Intelligent Miner, iSeries, Micro-Partitioning, NUMACenter, On Demand Business logo, POWER, PowerExecutive, PowerVM, PowerVM (logo), Power Architecture, Power Everywhere, Power Family, POWER Hypervisor, Power PC, Power Systems, Power Systems (logo), Power Systems Software, Power Systems Software (logo), PowerPC Architecture, PowerPC 603, PowerPC 603e, PowerPC 604, PowerPC 750, POWER2, POWER2 Architecture, POWER3, POWER4, POWER4+, POWER5, POWER5+, POWER6, POWER6+, pure XML, Quickr, Redbooks, Sequent (logo), SequentLINK, Server Advantage, ServeRAID, Service Director, SmoothStart, SP, System i, System i5, System p, System p5, System Storage, System z, System z9, S/390 Parallel Enterprise Server, Tivoli Enterprise, TME 10, TotalStorage Proven, Ultramedia, VideoCharger, Virtualization Engine, Visualization Data Explorer, Workload Partitions Manager, X-Architecture, z/Architecture, z/9.
A full list of U.S. trademarks owned by IBM may be found at: http://www.ibm.com/legal/copytrade.shtml.The Power Architecture and Power.org wordmarks and the Power and Power.org logos and related marks are trademarks and service marks licensed by Power.org.UNIX is a registered trademark of The Open Group in the United States, other countries or both. Linux is a trademark of Linus Torvalds in the United States, other countries or both.Microsoft, Windows, Windows NT and the Windows logo are registered trademarks of Microsoft Corporation in the United States, other countries or both.Intel, Itanium, Pentium are registered trademarks and Xeon is a trademark of Intel Corporation or its subsidiaries in the United States, other countries or both.AMD Opteron is a trademark of Advanced Micro Devices, Inc.Java and all Java-based trademarks and logos are trademarks of Sun Microsystems, Inc. in the United States, other countries or both. TPC-C and TPC-H are trademarks of the Transaction Performance Processing Council (TPPC).SPECint, SPECfp, SPECjbb, SPECweb, SPECjAppServer, SPEC OMP, SPECviewperf, SPECapc, SPEChpc, SPECjvm, SPECmail, SPECimap and SPECsfs are trademarks of the Standard Performance Evaluation Corp (SPEC).NetBench is a registered trademark of Ziff Davis Media in the United States, other countries or both.AltiVec is a trademark of Freescale Semiconductor, Inc.Cell Broadband Engine is a trademark of Sony Computer Entertainment Inc.InfiniBand, InfiniBand Trade Association and the InfiniBand design marks are trademarks and/or service marks of the InfiniBand Trade Association. Other company, product and service names may be trademarks or service marks of others.
5
IBM Power Systems
© 2008 IBM Corporation
Revised January 15, 2008
Notes on Benchmarks and Values
The IBM benchmarks results shown herein were derived using particular, well configured, development-level and generally-available computer systems. Buyers should consult other sources of information to evaluate the performance of systems they are considering buying and should consider conducting application oriented testing. For additional information about the benchmarks, values and systems tested, contact your local IBM office or IBM authorized reseller or access the Web site of the benchmark consortium or benchmark vendor.
IBM benchmark results can be found in the IBM Power Systems Performance Report at http://www.ibm.com/systems/p/hardware/system_perf.html.
All performance measurements were made with AIX or AIX 5L operating systems unless otherwise indicated to have used Linux. For new and upgraded systems, AIX Version 4.3, AIX 5L or AIX 6 were used. All other systems used previous versions of AIX. The SPEC CPU2006, SPEC2000, LINPACK, and Technical Computing benchmarks were compiled using IBM's high performance C, C++, and FORTRAN compilers for AIX 5L and Linux. For new and upgraded systems, the latest versions of these compilers were used: XL C Enterprise Edition V7.0 for AIX, XL C/C++ Enterprise Edition V7.0 for AIX, XL FORTRAN Enterprise Edition V9.1 for AIX, XL C/C++ Advanced Edition V7.0 for Linux, and XL FORTRAN Advanced Edition V9.1 for Linux. The SPEC CPU95 (retired in 2000) tests used preprocessors, KAP 3.2 for FORTRAN and KAP/C 1.4.2 from Kuck & Associates and VAST-2 v4.01X8 from Pacific-Sierra Research. The preprocessors were purchased separately from these vendors. Other software packages like IBM ESSL for AIX, MASS for AIX and Kazushige Goto’s BLAS Library for Linux were also used in some benchmarks.
For a definition/explanation of each benchmark and the full list of detailed results, visit the Web site of the benchmark consortium or benchmark vendor.
TPC http://www.tpc.orgSPEC http://www.spec.orgLINPACK http://www.netlib.org/benchmark/performance.pdfPro/E http://www.proe.comGPC http://www.spec.org/gpcNotesBench http://www.notesbench.orgVolanoMark http://www.volano.comSTREAM http://www.cs.virginia.edu/stream/ SAP http://www.sap.com/benchmark/ Oracle Applications http://www.oracle.com/apps_benchmark/ PeopleSoft - To get information on PeopleSoft benchmarks, contact PeopleSoft directly Siebel http://www.siebel.com/crm/performance_benchmark/index.shtmBaan http://www.ssaglobal.comMicrosoft Exchange http://www.microsoft.com/exchange/evaluation/performance/default.aspVeritest http://www.veritest.com/clients/reports Fluent http://www.fluent.com/software/fluent/index.htmTOP500 Supercomputers http://www.top500.org/Ideas International http://www.ideasinternational.com/benchmark/bench.htmlStorage Performance Council http://www.storageperformance.org/results
6
IBM Power Systems
© 2008 IBM Corporation
Revised October 9, 2007
Notes on Performance EstimatesrPerf
rPerf (Relative Performance) is an estimate of commercial processing performance relative to other IBM UNIX systems. It is derived from an IBM analytical model which uses characteristics from IBM internal workloads, TPC and SPEC benchmarks. The rPerf model is not intended to represent any specific public benchmark results and should not be reasonably used in that way. The model simulates some of the system operations such as CPU, cache and memory. However, the model does not simulate disk or network I/O operations.
rPerf estimates are calculated based on systems with the latest levels of AIX and other pertinent software at the time of system announcement. Actual performance will vary based on application and configuration specifics. The IBM eServer pSeries 640 is the baseline reference system and has a value of 1.0. Although rPerf may be used to approximate relative IBM UNIX commercial processing performance, actual system performance may vary and is dependent upon many factors including system hardware configuration and software design and configuration. Note that the rPerf methodology used for the POWER6 systems is identical to that used for the POWER5 systems. Variations in incremental system performance may be observed in commercial workloads due to changes in the underlying system architecture.
All performance estimates are provided "AS IS" and no warranties or guarantees are expressed or implied by IBM. Buyers should consult other sources of information, including system benchmarks, and application sizing guides to evaluate the performance of a system they are considering buying. For additional information about rPerf, contact your local IBM office or IBM authorized reseller.
7
IBM Power Systems
© 2008 IBM Corporation
OverviewProcessorsIBM Power™ Systems, POWER6™ Processor-based SystemsReliability, Availability, ServiceabilityCapacity on DemandPerformanceAdditional HardwareHardware Management ConsoleIO and NetworkingGreen ComputingStorageOperating SystemLinux®
Table of Contents
9
IBM Power Systems
© 2008 IBM Corporation
IBM Power Systems™
BladeCenter JS12JS22
570 575
595
Common FeaturesProcessor technologyService ProcessorVirtualization
550
520
560
10
IBM Power Systems
© 2008 IBM Corporation
POWER6 System HighlightsBalance System DesignPOWER6 Processor Technology
5th Implementation of multi-core design~100% higher frequencies4X increase in L2 Cache
POWER6 System ArchitectureNew generation of servers
Blades to High End offeringsEnhances memory implementationNew IO: PCIe, SAS / SATA, IO Drawers
Enhanced Virtualization Partition Mobility Workload PartitionsVirtual Shared Pools Int Virt Ethernet
Green TechnologiesProcessor Nap ModeMemory Power Down supportPower Save Mode
AvailabilityNew RAS features
Processor Instruction RetryAlternate Process Recovery
Workload MobilityHot Add resources
LPAR#2
LPARVIOS
LPAR#3
LPAR#1
Dedicated Processor
LPAR# 4
Power Hypervisor
Micro-Partition Shared Processor Pool
VSCSIVNET
BootHMC
35,400
30,000
21,000
10,175
234
164
71
553
0
10,000
20,000
30,000
40,000
0
100
200
300
400
500
600
11
IBM Power Systems
© 2008 IBM Corporation
IBM Power System Servers
Footprint, Packaging Blade Blade 19-inch 4U rack
Deskside19-inch 4U rack
Deskside 19-inch 4U rack
Processor POWER6 POWER6 POWER6 POWER6 POWER6
# of processors(# of cores) 2 4 1, 2, 4 2, 4, 6, 8 4, 8, 16
GHz clock 3.8 4.0 4.2 3.5, 4.2 3.6DDR2 GB memory 2 to 64 2 to 32 2 to 64 2 to 256 2 to 384Internal storage* 73GB – 292TB 73GB – 146TB 73GB – 30.6TB 73GB – 30.6TB 73GB – 39.6TBMaximum rPerf 14.71 30.26 31.48 68.20 100.3
PCIePCI-X slots
PCI-X 266 slotsGX bus slots
0 to 20 to 2
00
0 to 20 to 2
00
30 to 562 to 50
2
30 to 562 to 50
2
4 to 80 to 842 to 762 – 4
Max I/O drawers N/A N/A 8 8 12
Max micro-partitions 40 40 401 801 801
IBM i Operating System 5.4 & 6.1 5.4 & 6.1 5.4 & 6.1 5.4 & 6.1 5.4 & 6.1AIX® support 5.3, 6.1 5.3, 6.1 5.3, 6.1 5.3, 6.1 5.3, 6.1
Linux® support RHEL 4.5 / 5.1SLES 10
RHEL 4.5 / 5.1SLES 10
RHEL 4.5 / 5.1SLES 10
RHEL 4.5 / 5.1SLES 10
RHEL 4.5 / 5.1SLES 9 or 10
pSeries
pSeries
1 Requires purchase of optional feature to support micro-partitions *With maximum I/O drawers Optiona2 Preview Announcement Nov 13, 2007l
IBM BladeCenter®
JS22
Power 560Power
520Power
550IBM
BladeCenter® JS12
12
IBM Power Systems
© 2008 IBM Corporation
IBM Power System Servers
Footprint, Packaging 19-inch 4U rack 19-inch 4U rack 24-inch frame
by node 24-inch frame
by node Processor POWER6 POWER6 POWER6 POWER6
# of processors(# of cores) 2, 4, 8, 12, 16 4, 8, 16, 24, 32 32
8 ( 4.2 GHz ) To
64 ( 5.0 GHz )GHz clock 4.4, 5.0 4.2 4.7 4.2 / 5.0
DDR2 GB memory 2 to 768 2 to 768 32 to 256 16 to 4 TBInternal storage* 73GB – 79.2TB 73GB – 79.2TB 146.8GB – 5.1TB 146.8GB – 5.1TBMaximum rPerf 141.21 193.25 N/A 573
PCIePCI-X slots
PCI-X 266 slotsGX bus slots
4 to 160 to 1402 to 200
2 – 8
4 to 160 to 1402 to 200
2 – 8
0 to 40 to 200 to 16
2
0 0 to 240 / 180
0 to 4204 to 32
Max I/O drawers 32 32 1 12 / 30 Max micro-partitions 1601 1601 2541 2541
IBM i Operating System 5.4 & 6.1 5.4 & 6.1 N / A 5.4 & 6.1AIX® support 5.3, 6.1 5.3, 6.1 5.3, 6.1 5.3, 6.1
Linux® support RHEL 4.5 / 5.1SLES 9 or 10
RHEL 4.5 / 5.1SLES 9 or 10
RHEL 4.5 / 5.1SLES 10
RHEL 4.5 / 5.1SLES 10
pSeries
pSeries
1 Requires purchase of optional feature to support micro-partitions *With maximum I/O drawers Optiona
Power 575Power 595
Power 570 Power 570/32
13
IBM Power Systems
© 2008 IBM Corporation
Processors
14
IBM Power Systems
© 2008 IBM Corporation
2004 2007
POWER5™2010
POWER6POWER4™
Distributed Switch
Shared L2
1+ GHzCore
1+ GHzCore
2001
1.65+GHz
Core
Distributed Switch
Shared L2
1.5+GHz
Core Shared L2
1.9 GHzCore
Distributed Switch
1.9 GHzCore Cache
AdvancedCore Design
AdvancedSystem Features
POWER7*
1.5+ GHzCore
Distributed Switch
Shared L2
1.5+ GHzCore
2.3 GHz POWER5+Enhanced ScalingSimultaneous Multithreading (SMT)Enhanced Distributed SwitchEnhanced Core ParallelismImproved FP PerformanceIncreased memory BandwidthReduced Memory LatenciesVirtualization
Very High Frequencies 4-5 GHzEnhanced VirtualizationAdvanced Memory SubsystemAltiVec™ Vector SIMD InstructionsInstruction RetryDecimal Floating-PointDynamic Energy ManagementPartition MobilityStorage Protection KeysAlternate processor recovery
Chip Multi Processing- Distributed Switch- Shared L2Dynamic LPARs (32)
Workload AcceleratorsHighly Threaded Cores
L2 CacheAdvanced
System Features
4-5 GHz2 Cores Alti
Vec
BINARY COMPATIBILITY
POWER Technology
*All statements regarding IBM's future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only.
15
IBM Power Systems
© 2008 IBM Corporation
POWER Design
POWER6 Characteristics
3.5 – 5 GHz 790M transistors .065 micron
POWER6 Architecture
Memory+
GX++ Bridge
GX++ Bus Cntrl
Mem
ory
Cntrl
Mem
ory
Cntrl
Memory+
P6Core
AltiVec
L3Ctrl L3L3
CtrlL3
P6Core
AltiVec
4 MB L2
4 MB L2
Chipto Chip
Chipto ChipFabric Bus
Controller
Ultra-high frequency dual-core chip: ≥ 3.5 GHz7-way superscalar, 2-way SMT core
Up to 5 instr. for one thread, up to 2 for other9 execution units
2LS, 2FP, 2FX, 1BXU, 1VMX, 1DP790M transistors, 341 mm2 dieEnhanced Simultaneous Multi-Threading2x4MB on-chip L2 – point of coherencyOn-chip L3 directory and controllerTwo memory controllers on-chip
TechnologyCMOS 65nm lithography, SOI Cu
High-speed elastic bus interface at 2:1 freqFull error checking and recoveryDynamic power saving
Advanced Clock gating
16
IBM Power Systems
© 2008 IBM Corporation
POWER6 System Processor Options…
Memory+
GX+ Bridge
GX Bus Cntrl Mem
ory
Cntrl
Mem
ory
Cntrl
Memory+
P6Core
AltiVec
L3Ctrl L3L3
CtrlL3
P6Core
AltiVec
4 MB L2
4 MB L2
Fabric BusController
Memory+
GX+ Bridge
GX Bus Cntrl Mem
ory
Cntrl
Mem
ory
Cntrl
Memory+
P6Core
AltiVec
L3Ctrl L3L3
CtrlL3
P6Core
AltiVec
4 MB L2
4 MB L2
Fabric BusController
Memory+
GX+ Bridge
GX Bus Cntrl Mem
ory
Cntrl
Mem
ory
Cntrl
P6Core
AltiVec
L3CtrlL3
P6Core
AltiVec
4 MB L2
4 MB L2
Fabric BusController
Memory+
GX+ Bridge
GX Bus CntrlMem
ory
Cntrl
P6Core
AltiVec
L3CtrlL3
P6Core
AltiVec
4 MB L2
4 MB L2
Fabric BusController
Memory+
GX+ Bridge
GX Bus Cntrl Mem
ory
Cntrl
Mem
ory
Cntrl
P6Core
AltiVec
P6Core
AltiVec
4 MB L2
4 MB L2
Fabric BusController
Memory+
GX+ Bridge
GX Bus CntrlMem
ory
Cntrl
P6Core
AltiVec
P6Core
AltiVec
4 MB L2
4 MB L2
Fabric BusController
595 575, 570, 560, & 550 520, JS12, & JS22
17
IBM Power Systems
© 2008 IBM Corporation
POWER6 Packaging Options…
P6
Multi Chip ModulesPOWER6 Chip & L3
Power 595
Single Chip ModulePOWER6 & No L3
Power 520 / JS12 / JS22
P6L3
P6L3
Dual ChipPOWER6 Chip & L3
Power 550, 560, 570/32, & 575
Single Chip ModuleL3 & POWER6Power 570
P6
L3
L3
18
IBM Power Systems
© 2008 IBM Corporation
Processor History Overview….
POWER4414 mm2
1.1 – 1.3 GHz
POWER4+267 mm2
1.5 – 1.9 GHz
POWER5389 mm2
1.65 – 1.9 GHz
POWER5+245 mm2
1.9 – 2.3 GHz
POWER6341 mm2
3.5 – 5.0 GHz
2001 2004 20072002 2003 2005 2006
Technology Change
2008
POWER6341 mm2
4.2 – 5.0 GHzRefresh
Technology Change
No TechnologyChange
19
IBM Power Systems
© 2008 IBM Corporation
Power Systems Unification
20
IBM Power Systems
© 2008 IBM Corporation
BladeCenterJS22
Express
BladeCenterJS12
Express
System i
IBM BladeCenter IBM Power Servers
Power Systems Server Unification
i525i515 i595i570i550
System pp5-595p5-575p5-570p5-550p5-520
Power 520Express
Power 550Express
Power 570 Power 575 Power 595
21
IBM Power Systems
© 2008 IBM Corporation
Power Systems POWER6
22
IBM Power Systems
© 2008 IBM Corporation
BladeCenter JS12
POWER6 Blade
23
IBM Power Systems
© 2008 IBM Corporation
POWER6 JS12 Blade JS12 Blade
Architecture 2 core / 1 Socket @ 3.8 GHz
L3 Cache N / ADDR2 Memory 2GB to 64GB ( ChipKill )DASD / Bays 0 – 2 SAS disk ( 73 / 146 GB ) Daughter Card Options PCI-X and/or PCIe
Integrated Options Dual Port 10/100/1000 EthernetSAS Controller & USB
Fiber Support Yes ( via Blade Center )Media Bays 1 Blade CenterRedundant Power Yes BladeCenterRedundant Cooling Yes BladeCenterService Processor Yes
Virtualization AIX & Linux APVIntegrated Virtualization Manager
Blade Chassis BC-H, BC-E and BC-SNEBS Support Yes
24
IBM Power Systems
© 2008 IBM Corporation
Memory
DISK Power10Gbt
Power10Gbt
POWER6Dual Core
High-speed PCI- Express
connector
Optional I/O connector
MemoryDISK
JS12 Blade
25
IBM Power Systems
© 2008 IBM Corporation
BladeCenter JS22
POWER6 Blade
26
IBM Power Systems
© 2008 IBM Corporation
POWER6 JS22 BladeJS22 Blade
Architecture 4-core / 2 Socket @ 4.0 GHz
L3 Cache N / ADDR2 Memory 2GB to 32GB ( Chipkill™ )DASD / Bays 0 – 1 SAS disk ( 73 / 146GB ) Daughter Card Options PCI-X and/or PCIe
Integrated Options Dual Port 10/100/1000 EthernetSAS Controller & USB
Fiber Support Yes ( via Blade Center )Media Bays 1 BladeCenterRedundant Power Yes BladeCenterRedundant Cooling Yes BladeCenterService Processor Yes
Virtualization AIX & Linux PowerVM Integrated Virtualization Manager
Systems Management IBM Director and CSMIBM EnergyScale™
BC Chassis BC-H and BC-SWarranty 3 years
27
IBM Power Systems
© 2008 IBM Corporation
JS22 Blade
POWER6Dual Core
Memory
DISK Power10Gbt
Power10Gbt
POWER6Dual Core
High-speed PCI- Express
connector
Optional I/O connector
Memory
28
IBM Power Systems
© 2008 IBM Corporation
JS12 / JS22 Expansion Cards
CFFv (Vertical) expansion cards:QLogic 4GB 2 Port Fibre Channel Expansion Card (CFFv) Ethernet Expansion Card (CFFv) SAS Expansion Card (CFFv)Emulex 4GB Fibre Channel Expansion Card (CFFv)
CFFh (Horizontal) expansion cards:QLogic Ethernet and 4 GB Fibre Channel Expansion Card (CFFh)4X InfiniBand® DDR Expansion Card (CFFh)Cisco 4X InfiniBand DDR Expansion Card (CFFh)Voltaire 4X InfiniBand DDR Expansion Card (CFFh)
One combination form factor vertical (CFFv) may be installed with a combination form factor horizontal (CFFh) expansion card and one SAS HDD.
29
IBM Power Systems
© 2008 IBM Corporation
IBM BladeCenter JS12 vs JS22JS12 JS22
Architecture3.8GHz POWER6 SCM
2 core (1 Socket x 2 Core)Single Wide
4.0 GHz POWER6 SCM4 core (2 Socket x 2 Core)
Single Wide
Memory 2GB to 64GB DDR2 (Chip Kill) 533MHZ
2GB to 32GB DDR2 (Chip Kill) 667MHz
DASD / Bays 0-2 SAS disk (73 or 146 GB) 0-1 SAS disk (73 or 146 GB)Daughter Cards Legacy, SFF, or High speed DC Legacy, SFF, or High speed DC
Integrated FeaturesKeyboard, Video and Mouse
Dual Port 1Gb EthernetSAS Controller & USB
Keyboard, Video and MouseDual Port 1Gb EthernetSAS Controller & USB
Fiber Support Yes (via BladeCenter) Yes (via BladeCenter)Redundant Power Yes (via BladeCenter) Yes (via BladeCenter)Redundant Cooling Yes (via BladeCenter) Yes (via BladeCenter)
VirtualizationAIX 5L V5.3 & Linux
Advanced Power Virtualization (Standard)
Integrated Virtualization Manager
AIX 5L V5.3, AIX 6 & LinuxAdvanced Power Virtualization
(Standard)Integrated Virtualization Manager
Systems Management
IBM Director and CSMIBM EnergyScale Technology
IBM Director and CSMIBM EnergyScale Technology
OS Support AIX 5.3, AIX 6 , Linux, & IBM i AIX 5.3, AIX 6 , Linux, and IBM irPerf Performance 14.71 30.26
30
IBM Power Systems
© 2008 IBM Corporation
Power 520
POWER6
31
IBM Power Systems
© 2008 IBM Corporation
Power 520 - 4U Rack & DesksidePower 520 8203-E4A
Architecture 1, 2, or 4 cores @ 4.2 GHzL3 Cache: N/A
DDR2 Memory Up to 64GB (Buffered )
Internal SAS Disks Up to 6 DASD (3.5”)
ExpansionPCIe: 3 SlotsPCI-X 266: 2 Slots GX Bus: 2 Slots
Shared with PCIe 1 slot
Integrated SAS / SATA Yes Optional: RAID support
Integrated Ports 3 USB, 2 Serial, 2 HMCOptional: SAS port
Integrated Virtual Ethernet
Dual Port 10/100/1000 EthernetOptional: Quad 1Gbt or Dual 10Gbt
Media Bays 1 Slim-line DVD1 Half High Tape
Remote IO Drawers Yes / Max: 8 GX Bus connection: RIO2 / InfiniBand
Dynamic LPAR Up to 40 partitions Redundant Power OptionalRedundant Cooling Yes
32
IBM Power Systems
© 2008 IBM Corporation
Power 520 Physical Specifications:
Deskside/Desktop:Width: 328.5 mm (12.9 in) with tip foot
182.3 mm (7.2 in) without tip footDepth: 778 mm (30.6 in)Height: 540 mm (21.3 in)
Rack-Mount:Width: 440 mm (17.3 in)Depth: 538 mm (21.2 in)Height: 173 mm (6.8 in)
Weight:Rack-mount: 31.75 kg (70 lb)Deskside: 40.8 kg (90 lb)
33
IBM Power Systems
© 2008 IBM Corporation
Power 550
POWER6
34
IBM Power Systems
© 2008 IBM Corporation
Power 550 Rack & DesksidePower 550 8204-E8A
Architecture 2, 4, 6 or 8 cores @ 3.5 & 4.2 GHzL3 Cache: 32MB per chip
DDR2 Memory Up to 256GB (Buffered )
Internal SAS Disks Up to 6 DASD (3.5”)Optional SFF DASD
ExpansionPCIe: 3 SlotsPCI-X 266: 2 Slots GX Bus: 2 Slots
Shared with PCIe 2 slots Integrated SAS / SATA Yes Optional: RAID support
Integrated Ports 3 USB, 2 Serial, 2 HMCOptional: SAS port
Integrated Virtual Ethernet
Dual Port 10/100/1000 EthernetOptional: Quad 1Gbt or Dual 10Gbt
Media Bays 1 Slim-line DVD1 Half High Tape
Remote IO Drawers Yes / Max: 8 GX Bus connection: RIO2 / InfiniBand
Dynamic LPAR Up to 80 partitions NEBS YesRedundant Power OptionalRedundant Cooling Yes
35
IBM Power Systems
© 2008 IBM Corporation
Power 550 Physical Specifications:
Deskside/Desktop:Width: 282.5 mm (11.1 in) with tip foot
182.5 mm (7.2 in) without tip footDepth: 778 mm (30.6 in)Height: 540 mm (21.3 in)
Rack-Mount:Width: 440 mm (17.3 in)Depth: 730 mm (28.7 in)Height: 175 mm (6.89 in)
Weight: 54.4 kg (120 lb)
36
IBM Power Systems
© 2008 IBM Corporation
POWER6 Entry Systems ComparisonPower 520 Power 550
Processors 4.2 GHz 3.5 & 4.2 GHz
L3 Cache N / A 32MB / Chip
Pluggable Modules No YesDASD / Bays 6 (3.5) 6 (3.5) / 8 SFFMemory 64 GB 256 GB
Integrated SAS/SATA Yes Yes
PCIe / PCI-X 3 / 2Slot 1 Shared
3 / 2Slots 1 & 2 Shared
Integrated Ports 2 Sys Port / 3 USB 2 Sys Port / 3 USBIntegrated Virtual Ethernet Yes Yes
Media Bays Yes Yes
Remote IO Drawers Max 8 Max 8Dynamic LPAR Yes / 40 Yes / 80Redundant Power Yes Yes
NEBS No Yes
Form Factor 4U x 22.8” 4U x 29”
37
IBM Power Systems
© 2008 IBM Corporation
Power 560
POWER6
38
IBM Power Systems
© 2008 IBM Corporation
Power 560 Power 560 8234-EMAPower6 Processors 4 / 8 / 16 @ 3.6 GHz
L3 Cache 32 MB / Chip
Redundant Power & Cooling Yes
Redundant Server Processor Optional / Two Nodes minimum )
Redundant Clock Yes (Cold Detect) Two Nodes minimum
CoD No
Hot Node Add No
Concurrent Repair NoSingle Node Dual Nodes
Cores 4 or 8 16
DDR2 Memory (Buffered) Up to 192 GB Up to 384 GB
SAS Disk Bays (3.5”) 6 12
Media Bays 1 Slim-line 2 Slim-line
SAS/SATA Controller 1 2
PCI (Internal) 4 PCIe, 2 PCI-X 266 8 PCIe, 4 PCI-X 266
GX Bus Slots 2 3Dual Port 10/100/1000Quad Port 1 Gb (Optional)Dual Port 10 Gb (Optional
1 2
Remote I/O Drawers 8 Max 12 Max
Dynamic LPARs 80 160
39
IBM Power Systems
© 2008 IBM Corporation
550 560Rack Units 4U 8U
Processor cores 2 – 8 4 – 16
Frequency 3.5 GHz4.2 GHz 3.6 GHz
Memory 256 GB 384 GB
I/O Drawers 8 12
CoD No NoUpgradesFrom P5+
9406: Yes9133: No No
Concurrent Maintenance No No
HMC Optional Required
Memory Type Standard New FC
Power (Est.) 1400W 2400W
IBM Power Systems: 550 & 560 Positioning
40
IBM Power Systems
© 2008 IBM Corporation
Power 560 Bandwidth
Memory BandwidthL1 ( Data ) 51.2 GB/secL2 / Chip
16 core115.2 GB/sec921.6 GB/sec
L3 / Chip16 core
28.8 GB/sec230.4 GB/sec
Memory / Chip16 core
32 GB/sec256 GB/sec
Inter-Node Buses (16 core) 9.6 GB/secIntra-Node Buses (16 core) 57.6 GB/sec
Single NodeInternal I/O BusGX Bus Slot 1GX Bus Slot 2
Total I/O Bandwidth
7.2 GB/sec / node3.6 GB/sec / node4.8 GB/sec / node
24 GB/sec (16 core)
Calculations for 3.6 GHz processors and 667 MHz memory
41
IBM Power Systems
© 2008 IBM Corporation
Power 570
POWER6
42
IBM Power Systems
© 2008 IBM Corporation
Power 570 Power 570 9117-MMAPower6 Processors 4.4 / 5.0 GHzL3 Cache 32 MB / Chip
Redundant Power & Cooling Yes
Redundant Server Processor Optional ( Two Nodes minimum )
Redundant Clock Yes (Cold Detect) ( Two Nodes minimum )CoD YesHot Node Add Yes
Concurrent Repair Yes ( Nodes 2 / 3 / 4 )Single Node Four Nodes
Cores 2 / 4 16
DDR2 Memory (Buffered) 2-192 768
SAS Disk Bays (3.5”) 6 24
Media Bays 1 Slim-line 4 Slim-line
SAS/SATA Controller 1 4
PCI (Internal) 4 PCIe, 2 PCI-X 266 16 PCIe, 8 PCI-X 266
GX Bus Slots 2 8
Dual Port 10/100/1000Quad Port 1 Gb (Optional)Dual Port 10 Gb (Optional)
1 4
Remote I/O Drawers 8 Max 32 Max
Dynamic LPARs 40 160
43
IBM Power Systems
© 2008 IBM Corporation
POWER6 DDR2 Memory DIMMs
Back
DDR2 DDR2 DDR2 DDR2 DDR2 DDR2 DDR2 DDR2
DDR2 DDR2 DDR2 DDR2 DDR2 DDR2 DDR2 DDR2DDR2 DDR2
Front
Systems: Power 560, 570,570/32, 575, & 595Features / Benefits
Dual Sided Connector Pins3X Reliability of Industry Standard Memory
“Memory Power” SupportEnergy Savings ( At low utilizations )
On DIMM BufferingBetter Performance
44
IBM Power Systems
© 2008 IBM Corporation
Power 570/32
POWER6
45
IBM Power Systems
© 2008 IBM Corporation
Power 570/32 Power 570 9117-MMAPower6 Processors 4.2 GHzL3 Cache 32 MB / Chip
Redundant Power & Cooling Yes
Redundant Server Processor Optional ( Two Nodes minimum )
Redundant Clock Yes (Cold Detect) ( Two Nodes minimum )
CoD Yes
Hot Node Add Yes
Concurrent Repair Yes ( Nodes 2 / 3 / 4 )Single Node Four Nodes
Cores 8 32
DDR2 Memory (Buffered) 2-192 768
SAS Disk Bays (3.5”) 6 24
Media Bays 1 Slim-line 4 Slim-line
SAS/SATA Controller 1 4
PCI (Internal) 4 PCIe, 2 PCI-X 266 16 PCIe, 8 PCI-X 266
GX Bus Slots 2 8
Dual Port 10/100/1000Quad Port 1 Gb (Optional)Dual Port 10 Gb (Optional)
1 4
Remote I/O Drawers 8 Max 32 Max
Dynamic LPARs 40 160
46
IBM Power Systems
© 2008 IBM Corporation
POWER6 570 Processor Memory Packaging
L3
P PL2 L2
L3P P
L2 L2
4 Cores / Book
2 Cores / Book
POWER 570 Higher
FrequenciesUp to 16 Cores / System
POWER 570/32More ProcessorsUp to 32 Cores / System
L3P P
L2 L2
47
IBM Power Systems
© 2008 IBM Corporation
pSeries
p590 570/32Footprint, Packaging
24 in Rack42U
19 in Rack16U
Configurations 16 / 32 4 / 8 / 16 / 24 / 32
L2 Cache 1.9 MBPer Processor Chip
8 MBPer Processor Chip
L3 Cache 36MBPer Processor Chip
32MBPer Processor Chip
DIMMs/Max GB memory
128 DIMMS 2 to 1TB
96 DIMMs2 to 768GB
Max GB / Core 32 GB 24 GBMax PCI slots( Internal ) 0 6 per Node
Max: 24 ( 4 Nodes )LPARs 254 254
I/O Drawers 8160 IO Adapter Slots
32 IB ( AIX & Linux )192 IO Adapter Slots
Max Power 16.7 KW 5.6 KW
POWER5+ 590 & Power6 570/32 Product Comparison
570/32
p590
48
IBM Power Systems
© 2008 IBM Corporation
Power 575
POWER6
49
IBM Power Systems
© 2008 IBM Corporation
Power 575 Node Power 575 Node
Architecture32 Core node
1 – 14 Nodes / rack ( 448 Cores )4.7 GHz
Cache L3: 32MB / ChipDDR2 Memory 32 to 256 GB ( Buffered )Internal Disks 2 SAS SFF DASD ( 2.5”)
Expansion PCIe: Up to 4 SlotsPCI-X: Up to 2 slots
Integrated SAS Yes
Expansion Slots Dual GX Bus AdaptersIntegrated Ethernet
Two Dual 10/100/1000 EthernetOptional: Dual 10Gb
POWERN+1 Support
1 - 4 Nodes 2 Line Cords5+ Nodes 4 Line Cords
Cooling Combination Water / Air
Remote IO Drawers
Yes Quantity: 1PCI-X ( 20 Slots & 16 DASD )
50
IBM Power Systems
© 2008 IBM Corporation
Photo of Power 575 Mechanical Model
Power 575 Water Cooled Node
51
IBM Power Systems
© 2008 IBM Corporation
Top View
I/O Unit(Lite or FF)
PCI Riser(2 x PCIe or
1x PCIe, 1x PCI-X DDR2)
PCI Riser(2 x PCIe or
1x PCIe, 1x PCI-X DDR2)
Dual 2 port 4x Host Channel Adapter(Displaces Lower PCI Slot)
Processor UnitI/O Section
Air Moving Device(Fans)
16x DCM(p6 + L3)
32 x DIMM 32 x DIMM
Cold Plate
Dual 2 port 4x Host Channel Adapter(Displaces Lower PCI Slot)
52
IBM Power Systems
© 2008 IBM Corporation
Water Cooling….Redundant Modular Water Unit
With Non-Redundant Facilities Water (MWU)
Redundant Modular Water UnitWith Redundant Facilities Water (MWU)
MWUMWU
FacilityWater
MWUMWU
FacilityWater
53
IBM Power Systems
© 2008 IBM Corporation
Power 595
POWER6
54
IBM Power Systems
© 2008 IBM Corporation
Power 595 Power 595 9119-FHA
Architecture POWER6: 8 / 16 - 64 core4.2 and 5.0 GHz
Cache L2: 4MB/Core L3: 32MB/ChipDDR2 Memory 16GB to 4 TB ( Buffered / ChipKill )
Processor / MemoryNodes
Up to 8 Nodes( 8 Cores & Max: 512 GB Memory )
Point to Point InterconnectProcessors / MemoryAvailability Hot Add & Concurrent Repair
GX Bus ( System Bus) 4 per Node
Remote IO Drawers( IO Expansion )
RIO-2 and 12X Max:30 DrawersDrawer: 20 IO slots & 16 DASD
Virtualization Up to 254 partitions Redundant Service Processor
CEC: Yes Node: YesYes / Hot Failover
Redundant Power & Cooling Yes / Concurrent Repair
Redundant Clock Yes / Hot Failover
Power / Thermal Active Energy Manager (Power Save)
Warranty 1 Year
55
IBM Power Systems
© 2008 IBM Corporation
Power 595 Front Rack View
IO Drawers
Dual Clocks
Bulk Power
Nodes
Enet HubLight Strip
Dual System
Controllers
Dual NodeControllers
Midplane
Up to 8 NodesSplit 4 above / 4 below8 Cores and Up to 512GB Memory
Up to 3 Remote IO DrawersUp to 60 PCI SlotsUp to 48 DASD Bays
Dual ClocksDual System ControllersDual Node ControllersDual Power SuppliesDual Ethernet HubsDual LightstripsRedundant CoolingAlternate Processor RecoveryConcurrent Repair
Availability Features
Packaging
56
IBM Power Systems
© 2008 IBM Corporation
Max Configuration 64 Cores / 4 TB Memory32 GX Buses
8 cores / Up to ½ TB Memory4 GX Ports / 2 Node Controllers
Power 595 System CEC
GX
GX
GX
GX
NC
NC
L 3
L 3
P6
L2P6
L2 L 3
L 3
P6
L2P6
L2
L 3
L 3
P6
L2P6
L2 L 3
L 3
P6
L2P6
L2
Dual Node Controllers
GX Bus
DIMMs
DIMMs DCA Bulk PowerDCA Bulk Power
ClockClock
57
IBM Power Systems
© 2008 IBM Corporation
DDR2 DDR2 DDR2 DDR2 DDR2 DDR2 DDR2DDR2 DDR2 DDR2
Interposer Buffer Chip
Power 595: POWER5 590/595 Memory DIMMs upgrade…
DIMM Slot
POWER5 DDR2 memory transforms into Buffered Memory supported by POWER6
POWER5 DDR2 non buffered Memory
58
IBM Power Systems
© 2008 IBM Corporation
POWER5 to Power System 595 Upgrade Options
Unified Power 595
POWER6
No upgrade path from a POWER6 570 to a POWER6 5959406-550 upgrade to i570 withdrawn July 2008
Power 595p5-595
i5-595
i5-570
p5-590
System i System
System p System
POWER5
Power System
59
IBM Power Systems
© 2008 IBM Corporation
Power 595 BandwidthMemory Bus Size BandwidthL1 ( Data ) 2 x 8B 80 GB/sec
L2 2 x 32B 160 GB/sec
L3 4 x 8B 80 GB/sec2.56 TB / sec per System
MemorySystem
4 x 1B Write4 x 2B Read
42.7 GB/sec1366 GB/sec per System
Intra-NodeBuses
System6 x 8B
40 GB/sec per chip160 GB /sec per Node
1280 GB /sec per System
Inter-NodeBusesSystem
4 x 8B28 Interconnects
26.7 GB/sec746.7 GB/sec per System
GX Bus 2 x 4B 20 GB/sec640 GB/sec per System
60
IBM Power Systems
© 2008 IBM Corporation
Capacity on Demand
61
IBM Power Systems
© 2008 IBM Corporation
Capacity Upgrade on DemandUpgrade system with processors and/or memoryNo special contracts, no required monitoring (no ability to turn off the capacity)Purchase agreement
On/Off Capacity on DemandTemporary use of requested number of processors or amount of memory Client selects the capacity and activates the resource (registered system)Capacity can be turned on and off by the clientInformation captured by IBM (or reported to IBM)Rental agreement
Utility Capacity on DemandProcessor resources only / Measured by processor minutesCapacity can be turned on and off by the clientPrepaid or post pay Requires a minimum of AIX V5.3 or higher and APV
Trial Capacity on DemandAllow clients to test the effects of additional processors and/or memory Partial or total activation of processors and memoryResources available for fixed timeNo formal commitment required
Dynamic Processor Sparing• Automated replacement of deallocated processors• Unassigned or inactive processors
Capacity on Demand for POWER6 Processor-based Systems
62
IBM Power Systems
© 2008 IBM Corporation
ConfigurationsPower 595: 4.2 / 5.0 GHzCores: 4 active / 28 CoDCores: 4 active / 60 CoD
Backup ModeProcessors: 32 / 64 active
Power System 595 Capacity Back-Up Option...
0
100
200
300
400
500
600
4 Cores 32 Cores 64 Cores
4.2 GHz 5.0 GHz
CBU Resources
rPerf
Capacity Back Up with POWER6– POWER6 595 ( 4.2 GHz or 5.0 GHz )– Base configuration: 4 Active processors– AIX V5.3 / V6.1, and Linux support– On / Off Days included with CBU Configurations
4 / 32 1800 CoD Processor days 4 / 64 3600 CoD Processor days
No Permanent Activation
63
IBM Power Systems
© 2008 IBM Corporation
Reliability, Availability and Serviceability
64
IBM Power Systems
© 2008 IBM Corporation
Processor Instruction Retry Alternate Processor Recovery First Failure Data CaptureDDR Chipkill memoryBit-steering/redundant memoryService Processor Failover*Dynamic Firmware Maintenance*Hot I/O Drawer Add*I/O error handling extended beyond base PCI adapterECC extended to inter-chip connections for the fabric/processor busesMemory and L3 Cache soft scrubbing
Hardware AssistedL2 & L3 Cache Line DeleteHardware Assisted Memory ScrubbingLive Partition Migration
Primary POWER RAS Features
HMC required to enable these functions..
65
IBM Power Systems
© 2008 IBM Corporation
Primary POWER RAS Features - Continued
HMC required to enable these functions..
Hot Add: Power 570 Processor & MemoryHot Add: Power 590 Processors & MemoryConcurrent Repair: 570 Nodes 2/3/4 (Hot) and Node 1 (Cold)Concurrent Repair: 590 All NodesRepairRedundant power, fansDynamic Processor DeallocationDynamic processor sparing ECC memoryPersistent memory deallocationHot-plug PCI slots, fans, powerInternal light path diagnosticsHot-swappable disk bays
66
IBM Power Systems
© 2008 IBM Corporation
Performance
67
IBM Power Systems
© 2008 IBM Corporation
Note:Go to system sales or PartnerInfo and download esbmi and select the charts that are most appropriate for your use.
Due to the constantly changing nature of benchmark standings, those charts are kept separate and updated the 2nd of
every month.
68
IBM Power Systems
© 2008 IBM Corporation
I/O Hardware
69
IBM Power Systems
© 2008 IBM Corporation
POWER6 Remote I/O Drawer 19” Rack19” IO Drawer
POWER6 Processor-based Servers only– Max 4 of drawers per GX Bus½ x 19” 4U Rack-mount– Optional enclosure for two individual drawersSix PCI Adapter Slots
– PCI-X 2.0 (DDR) 64-bit @ 266 MHz (2 GB/s)“InfiniBand” Host Interface (Loop Architecture)
– 12 x 2.5Gb/s Full Duplex (30 Gb/sec)– Short Run (Intra-rack) or Long Run (Inter-rack)– Four cable lengths: 0.6, 1.5, 3.0, & 8.0mCustomer SetupConcurrently Maintainable Redundant PowerConcurrently Maintainable Redundant CoolingHot Drawer AddBlind-swap Cassettes for Adapter Cards
–Hot-pluggable
Two drawers
PCI-X 266Slots12X Channel
ConnectionSupported SystemsPower 520 / 550 560 / 570
70
IBM Power Systems
© 2008 IBM Corporation
Back
Front
16 DASD
GX Dual Port12X ChannelConnections
POWER6 Remote I/O Drawers 24” Racks
SCSICntrl
24” I/O Drawer4U I/O DrawerPCI-X & PCI-X 266 Support 6 PCI-X and 14 PCI-X 266 per
Drawer All adapter slots 64bitsGX Dual Port 12X ChannelInfiniBand Interface30 Gb/sec
Supports 16 Hot-Plug disk drivesFour 4-pack disk / Ultra3 SCSI72.8 / 146.8 / 300 GB Multiple cabling options Hot Drawer AddBlind Swap Adapter CardsHot Pluggable
PCI-X 133 PCI-X 266
Dual or Single Path
SCSICntrl
SCSICntrl
SCSICntrl
Supported SystemsPower 575 / 595
71
IBM Power Systems
© 2008 IBM Corporation
8Gb Fiber Channel
Description:Dual PortedPCIe x4 ArchitectureMultiple speeds: 2Gb, 4Gb, or 8GbSupported Systems: Power 520 / 550 / 560 / 570 / 575Supported OS: AIX and LinuxNPIV enabledFeature Code: 5735
PCIeFC
FC8Gb FiberChannel
Link
NPIV
72
IBM Power Systems
© 2008 IBM Corporation
Green Computing
73
IBM Power Systems
© 2008 IBM Corporation
Power TrendingCollect and Report Power usage data
Thermal ReportingCollect and display Inlet and Exhaust Temperatures
Static Power SaveSave maximum power by dropping voltage and frequency
Power CapEnforces a user-specified power capUses processor and memory throttling
OversubscriptionQuickly lower power when failure occurs.
Processor NapPut processors into low power mode when they are deconfigured or not used.
EnergyScale Functional Description
74
IBM Power Systems
© 2008 IBM Corporation
Dynamic Power Save -- Optimize Power / PerformanceTPMD implements algorithms to optimize power vs. performance
Dynamic Power Save -- with Performance FloorUser specifies a minimum acceptable “performance floor”
System Turbo -- Maximum PerformanceProvides maximum performance by raising voltage and frequency
IO Tower/Drawer Power TrendingDrawer, Tower and IO Frame power reporting
Server Power DownEvacuate Servers and power them off
EnergyScale Functional Description - Continued
75
IBM Power Systems
© 2008 IBM Corporation
PowerVM
76
IBM Power Systems
© 2008 IBM Corporation
PowerVM…
AIX Workload Partitions
PowerVM Editions featureMicro-Partitioning™Virtual I/O ServerIntegrated Virtualization ManagerPartitioning PoolingNPIVLx86
Logical PartitioningVirtual ProcessorsVirtual NetworkingVirtual MediaVirtual Tape
Hardware & Software delivering industry-leading virtualization on IBM POWER processor-based processors for UNIX, Linux & IBM i
Live Partition MobilityLive Application Mobility
77
IBM Power Systems
© 2008 IBM Corporation
Operating Systems
78
IBM Power Systems
© 2008 IBM Corporation
AIX
79
IBM Power Systems
© 2008 IBM Corporation
POWER6 Delivers with Your Choice of AIX or Linux
Linux on POWERPOWER and x86 apps [2H07]PowerVMReliability, Availability, Serviceability featuresScalability to 128 threads
AIX 6*Virtualization
Workload PartitionsLive Application Mobility
SecurityAvailabilityManageabilityBinary compatible**
Broad application selectionWide range of workloadsReduced ComplexityPotential cost savings with consolidationLive Partition Mobility
Linux, AIX V5.3 and AIX V6.1
Binary compatible with existing applications on POWER6*Micro-PartitioningMainframe-inspired RAS features hardware and operating systemScalability up to 128 threads
AIX 5L V5.2/5.3
*Complete details on AIX binary compatibility can be found at http://www.ibm.com/servers/aix/os/compatibility/
80
IBM Power Systems
© 2008 IBM Corporation
AIX Binary Compatibility
Guarantee
*Complete details on AIX binary compatibility can be found at http://www.ibm.com/servers/aix/os/compatibility/
81
IBM Power Systems
© 2008 IBM Corporation
POWER6 ExploitationSoftware Reliability Availability ServiceabilityEnhancements to existing Virtualization TechnologiesWorkload Partitions ( Software based Virtualization )Application Mobility ( Cross system Workload Mobility )64-bit Kernel onlyIntegrated Multilevel SecurityRole Base Access Control ( Partial Root base )Encrypted File systemCAPP EAL4+ and LSPP Security CertificationSolution Performance TuningAIX Kernel Hot-PatchingDynamic Tracing for AIXEase of Use
Portal base SMT, LPAR Simplification
AIX 6 Features….
82
IBM Power Systems
© 2008 IBM Corporation
AIX Editions
83
IBM Power Systems
© 2008 IBM Corporation
AIX Editions…..
AIX 5.3 Management Edition bundle consisting ofAIX V5.3Tivoli® Application Dependency Discovery ManagerIBM Tivoli MonitoringIBM Usage & Accounting Mgr Virtualization Edition for Power Systems
AIX 6.1 Enterprise Management bundle consisting ofAIX V6.1PowerVM AIX Workload Partitions ManagerTivoli® Application Dependency Discovery ManagerIBM Tivoli MonitoringIBM Usage & Accounting Mgr Virtualization Edition for Power Systems
84
IBM Power Systems
© 2008 IBM Corporation
IBM i
85
IBM Power Systems
© 2008 IBM Corporation
V6R1• Major SW release (~3.0 MLoC)• New DB2 Functions• IOPless boot from SAN• IPV6 • System Director Navigator• Safe Computing
•SLIC Signing & S/R Encryption•Intrusion Detection•Encrypted backups and Data on disk
Virtualization• IBM i Storage• VIOS SupportPerformance • Performance Management ( Web based )• Improved Storage Performance• 64K Large Page Support/exploitation• 64-bit IBM Technology JVMHigh Availability• System HASM Product• SPOOL Modernization• Disk Instrumentation
V5R4M5 (POWER6 enablement)• IBM i V5R4 Refresh• IOPless WAN Adapter support• IOPless Op Console• Software Enablement for:
• Additional IOPless devices• PCI-Express Devices• Serial-Attached SCSI (SAS)
Availability• RAID Hot Spare
Refresh• Content Manager• Domino• PHP• WDSC
IBM i Operating Systems
86
IBM Power Systems
© 2008 IBM Corporation
Linux
87
IBM Power Systems
© 2008 IBM Corporation
● Enterprise Class Computing with Linux on POWER ( LoP )●Flexibility with LPAR, dynamic LPAR, and virtualization features●Reliability with built in self-healing capabilities●Power Architecture/Servers include POWER5, POWER6 and
PowerPC970 ( JS20, JS21 blades )
● Linux distributions available for LoP: - SUSE LINUX Enterprise Server 9 or 10 for POWER (SLES 9, SLES 10) - Red Hat Enterprise Linux 4, 5 for POWER (RHEL)
● Technical support available through IBM SupportLine contract. - SUSE LINUX and Red Hat, Inc. also provide support, upgrades and maintenance
●Orderable from IBM or directly from Linux distributors
● For more information about Linux running on IBM Power Systems servers:● http://www.ibm.com/systems/p/linux/
● http://www.redhat.com/rhel/server/● http://www.novell.com/products/server/
Linux on POWER*
88
IBM Power Systems
© 2008 IBM Corporation
IBM Director 6.1
89
IBM Power Systems
© 2008 IBM Corporation
AIX
FSP PHYP
SLES RHEL VIOS AIX
PHYP
SLES RHEL IVM (VIOS)
MM
JS21AIX SLES RHEL HS21
Win
HMC
HMC: Hardware Management Console WPAR: Workload Partition (Container)
IVM: Integrated Virtualization Manager PHYP: POWER Hypervisor
VIOS: Virtual IO Server (virtual IO and Layer 2 bridge) BMC: Baseboard Management Controller
MM: Management Module SMP: Symmetric Multi Processor
FSP: Flexible Service Processor
POWER6 System Blade Center POWER 5 System
AIXWPAR
WPAR
WPAR
WPAR AIX (SMP)
PHYP FSP
IBM Systems Director 6.1Physical and virtual platforms Server, Storage, Networking
Foundation Management
Advanced Management
Inventory HealthConfig Update
IBM Systems Director Console
IBM i IBM i
IBM Systems Director for Power Topology
BMC/FSP
Availability WorkloadImage Energy Mgt
90
IBM Power Systems
© 2008 IBM Corporation
Automatic Discovery and Inventory:POWER resources and connected storage which includes the
collection of both hardware and software inventory. HMC, CEC, LPAR, AIX, pLinux, HMC, VIOS, FSP, and Virtual
Networking components – bridges and VLANS)
Visualize various POWER resource:Topologies and relationship across physical server and virtual
serversCEC, HMC, VIOS, LPAR, devices, AIX, pLinux and Virtual
Networking components, virtual disks, logical volumes and associated volume groups.
Discovery and documentation of full system configurationPhysical and virtual IO resources and association/relationship (for
configuration recovery – i.e. System plan).
Director 6.1 Power Capabilities:
91
IBM Power Systems
© 2008 IBM Corporation
Show Health and Status of Physical and Virtual ServersHMC and VIOS. Show Alerts: Hardware failures and system logs from VIOS, HMC
and the operating systems.
Base Monitoring:OS Metrics: CPU and memory utilizationFile system metrics across hosts and virtual servers. Historical and OS events monitoring. View CPU utilization metrics for environments that contain both
shared and dedicated processors for both host and virtual servers.
Director 6.1 Power Capabilities:
92
IBM Power Systems
© 2008 IBM Corporation
Download, Manage, and apply recommended Updates:AIX, pLinux, i5OS, HMC and System Firmware
Deployment/Provisioning/Planning Ability to configure new systems or clone systems using system
plans Deployment of OS and VIOS on a LPAR via HMC.
Base Virtualization ManagementSupport key lifecycle LPAR and mobility operations
Within single HMC domain) operations.
Consolidated Interface Integration of tasks for Key Power Resource Managers
HMC, IVM/VIOS, AIX and i5OS management consoles
Director 6.1 Power Capabilities:
93
IBM Power Systems
© 2008 IBM Corporation
Comprehensive CLI interface:Discovery/Health/Update/Deployment, LPAR virtualization lifecycle
and mobility, power control and management
Energy Management – Active Energy ManagerMonitoring, reporting, capping (both a server and group), and
controlling power consumption. Receive power status and alerts. Energy Thresholding - Allow a user to set a power or temperature
threshold, and be notified when it is reached (or allow an action to automatically be taken). Full CLI for all key AEM functionality. Support of AEM Server on AIX.
Enterprise Integration and Manageability Out-of-the box management utilizing standard CIM profiles for AIX,
pLinux, i50S, HMC, and VIOS resources
Director 6.1 Power Capabilities:
94
IBM Power Systems
© 2008 IBM Corporation
High Availability
95
IBM Power Systems
© 2008 IBM Corporation
High availability solutions for UNIX, i and Linux clientsPowerHA
Cluster management solutions High AvailabilityCan enable near continuous application serviceMinimize impact of planned and unplanned outages
IBM PowerHA™ for AIX® and Linux (formerly HACMP™)IBM PowerHA for i (formerly HASM)
www.ibm.com/systems/power/software/availability
96
IBM Power Systems
© 2008 IBM Corporation
What is PowerHA?
Business Continuity Solutions for
World wide commerce
Mission-critical applications
Disaster recovery
IBM storage optimization
Integrated optimization for AIX and i
The future with IBM Research & Development
High Availability and Disaster Recovery solutions from IBM for your mission-critical UNIX, i and Linux applications