View
519
Download
0
Category
Preview:
Citation preview
GESecurity
Kilsen Fire Systems Product Catalogue
g
In this catalogue you will find a wide range of
Fire Protection equipment from GE Security.
GE Security is a global technology leader dedicated
to supporting the needs of the rapidly growing
electronic security industry and to expanding
current technologies, products and services that
create revenue growth opportunities for its
customers. As part of the GE family, GE Security
shares the spirit of innovation that has
distinguished GE for well over 100 years. GE
Security's commitment to the ongoing success of
its partners and affiliates means that we maintain
a sharp focus on product and service innovation,
world-class manufacturing practices and
operational excellence.
GE Security is a worldwide organisation with sales
and technical support operations in 27 countries,
and manufacturing and logistics operations in
Europe, the U.S. and China.
GE Security has expertise in all areas of electronic
security, including:
Intrusion and Fire Protection
Electronic Access and Facility Management
Key Management and Remote Access Systems
and Services
Fibre Optic Transmission and Reception
Equipment
CCTV, Digital Video and Surveillance Equipment
Video Multiplexing and Digital Storage
When you're looking for the finest in Fire
Protection products with leading-edge
technology and the backing of a world leader, you
need look no further than this catalogue.
GE Security,unrivalled expertise in Fire Protection
Conventional Fire Systems
Page : 3
NKB602Conventional fire alarm panel with 2 zones
The NKB600 Series microprocessor controlled, conventional fire panelsincorporate state of the art technology, reliability, ease of installationand maintenance in a basic package. They are compatible withconventional detectors such as the Kilsen 200, 300, 500 and 700 seriesdevices. The NKB602 has 2 conventional zones.
Specifications
Supply Voltage 125/230 VAC @ 50/60 Hz
Mains fuse (Type 5x20 mm) 0.5/0.25 A
Total consumption < 20 W
Nominal Output Voltage 24 VDC
Batteries
Recommended batteries 2 off 1.9 Ah, 12 V
Fuse Rating 1 A
Maximum load current < 100 mA
Zone
Maximum Load 72 mA
Maximum number ofdetectors
20
Ouput voltage 22 to 28 VDC
End-of-line resitance 4k7 Ohm
Manual call point resistance 100 Ohm, 2 W
Outputs
Fire alarm 24 VDC ± 15%, 300 mA
Fault alarm (Fail-to-safe) 24 VDC ± 15%, 100 mA
Environmental
Working temperature +5 to +40°C
Storage temperature -10 to +70°C
Relative humidity 95 % (non-condencing)
Physical Characteristics
Size (w x h x d) 305 x 295 x 100 mm
Weight without batteries 3 kg
Ordering Information
Conventional fire alarm panel with 2 zonesNKB602
Modern, elegant designE
Compact models for 2, 4 and 6 zonesE
Microprocessor controlledE
Multilingual keyboardE
2 Access levelsE
Differentiation between alarms from manual call pointsand automatic detectors in the same zone
E
Acoustic indications for fire and faultE
Optical indications for fire and fault by zoneE
Low maintenanceE
Compatible with all ranges of KILSEN conventionaldetectors
E
Conventional Fire Systems
Page : 4
NKB604Conventional fire alarm panel with 4 zones
The NKB600 Series microprocessor controlled, conventional fire panelsincorporate state of the art technology, reliability, ease of installationand maintenance in a basic package. They are compatible withconventional detectors such as the Kilsen 200, 300, 500 and 700 seriesdevices. The NKB604 has 4 conventional zones.
Specifications
Supply Voltage 125/230 VAC @ 50/60 Hz
Mains fuse (Type 5x20 mm) 0.5/0.25 A
Total consumption < 20 W
Nominal Output Voltage 24 VDC
Batteries
Recommended batteries 2 off 1.9 Ah, 12 V
Fuse Rating 1 A
Maximum load current < 100 mA
Zone
Maximum Load 72 mA
Maximum number ofdetectors
20
Ouput voltage 22 to 28 VDC
End-of-line resitance 4k7 Ohm
Manual call point resistance 100 Ohm, 2 W
Outputs
Fire alarm 24 VDC ± 15%, 300 mA
Fault alarm (Fail-to-safe) 24 VDC ± 15%, 100 mA
Environmental
Working temperature +5 to +40°C
Storage temperature -10 to +70°C
Relative humidity 95 % (non-condencing)
Physical Characteristics
Size (w x h x d) 305 x 295 x 100 mm
Weight without batteries 3 kg
Ordering Information
Conventional fire alarm panel with 4 zonesNKB604
Modern, elegant designE
Compact models for 2, 4 and 6 zonesE
Microprocessor controlledE
Multilingual keyboardE
2 Access levelsE
Differentiation between alarms from manual call pointsand automatic detectors in the same zone
E
Acoustic indications for fire and faultE
Optical indications for fire and fault by zoneE
Low maintenanceE
Compatible with all ranges of KILSEN conventionaldetectors
E
Conventional Fire Systems
Page : 5
NKB606Conventional fire alarm panel with 6 zones
The NKB600 Series microprocessor controlled, conventional fire panelsincorporate state of the art technology, reliability, ease of installationand maintenance in a basic package. They are compatible withconventional detectors such as the Kilsen 200, 300, 500 and 700 seriesdevices. The NKB606 has 6 conventional zones.
Specifications
Supply Voltage 125/230 VAC @ 50/60 Hz
Mains fuse (Type 5x20 mm) 0.5/0.25 A
Total consumption < 20 W
Nominal Output Voltage 24 VDC
Batteries
Recommended batteries 2 off 1.9 Ah, 12 V
Fuse Rating 1 A
Maximum load current < 100 mA
Zone
Maximum Load 72 mA
Maximum number ofdetectors
20
Ouput voltage 22 to 28 VDC
End-of-line resitance 4k7 Ohm
Manual call point resistance 100 Ohm, 2 W
Outputs
Fire alarm 24 VDC ± 15%, 300 mA
Fault alarm (Fail-to-safe) 24 VDC ± 15%, 100 mA
Environmental
Working temperature +5 to +40°C
Storage temperature -10 to +70°C
Relative humidity 95 % (non-condencing)
Physical Characteristics
Size (w x h x d) 305 x 295 x 100 mm
Weight without batteries 3 kg
Ordering Information
Conventional fire alarm panel with 6 zonesNKB606
Modern, elegant designE
Compact models for 2, 4 and 6 zonesE
Microprocessor controlledE
Multilingual keyboardE
2 Access levelsE
Differentiation between alarms from manual call pointsand automatic detectors in the same zone
E
Acoustic indications for fire and faultE
Optical indications for fire and fault by zoneE
Low maintenanceE
Compatible with all ranges of KILSEN conventionaldetectors
E
Conventional Fire Systems
Page : 6
NK702Conventional fire panel with 2 fire alarm zones
The NK700 series of conventional fire alarm and extinguishing controlpanels is the ideal solution for small to medium-sized installations. Verypowerful and cost-effective, they are extremely simple to install anduse due to their ergonomic, advanced design. The NK704 has 4conventional zones.
Specifications
Supply voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 Hz
Batteries
Capacity 2 x 2.3 Ah
Fuse rating 2 A
Zone
Maximum load 94 mA
Max. number of detectors perzone
20
Maximum zone resistance 44 ohm
Sounders
Maximum load 250 mA
Delay Selectable 0 - 9 min
Relay outputs (excludingsounders)
1 A @ 30 VDC
Extinguishing relay outputs
Maximum load NA
Fuse rating NA
Auxilliary output 250 mA
24 VDC Resetable output
Maximum load 100 mA
Reset time 3 s
Environment
Working temperature -5 °C to +40 °C
Relative humidity 95 % (non condensing)
IP rating IP30
Physical characteristics
Size (mm) 297 (w) x 307 (h) x 105 (d)
Weight (without batteries) 3.6 kg
Ordering Information
Conventional fire panel with 2 fire alarm zonesNK702
Modern, attractive designE
Microprocessor-controlledE
From 2 up to 16-zonesE
EN54 approvedE
2 User access levelsE
2 Monitored sounder outputsE
One-man test capabilityE
24 Volt resetable outputE
External 'Class Change' facilityE
Alarm output with potential free relayE
Common fault output with potential free relay E
External watchdogE
Active end-of-line supportE
Addional optional modules with supervised or relayoutputs
E
Conventional Fire Systems
Page : 7
NK704Conventional fire panel with 4 fire alarm zones
The NK700 series of conventional fire alarm and extinguishing controlpanels is the ideal solution for small to medium-sized installations. Verypowerful and cost-effective, they are extremely simple to install anduse due to their ergonomic, advanced design. The NK704 has 4conventional zones.
Specifications
Supply voltage 230 VAC @ 50 Hz (±10%)
Batteries
Capacity 2 x 7.5 Ah
Fuse rating 1 A
Zone
Maximum load 72 mA
Max number of detectors 20
Sounders
Maximum load 300 mA
Relay outputs (excludingSounders)
2 A @ 250 V
Extinguishing relay outputs
Maximum load NA
Fuse rating NA
Open collector outputs 15 mA
Auxilliary output
Maximum load 300 mA
24 V resetable output
Maximum load 150 mA
Reset time 4 seconds
Delays
Sounder selectable 0.15 & 60 s
Relay module 3 to 180 s
Enviroment
Working temperature +5°C to +40 °C
Relative humidity 95 % (non-condensing)
Ordering Information
Conventional fire panel with 4 fire alarm zonesNK704
Modern, attractive designE
Microprocessor-controlledE
From 2 up to 16-zonesE
EN54 approvedE
2 User access levelsE
2 Monitored sounder outputsE
One-man test capabilityE
24 Volt resetable outputE
External 'Class Change' facilityE
Alarm output with potential free relayE
Common fault output with potential free relay E
External watchdogE
Active end-of-line supportE
Addional optional modules with supervised or relayoutputs
E
Conventional Fire Systems
Page : 8
NK708Conventional fire panel with 8 fire alarm zones
The NK700 series of conventional fire alarm and extinguishing controlpanels is the ideal solution for small to medium-sized installations. Verypowerful and cost-effective, they are extremely simple to install anduse due to their ergonomic, advanced design. The NK708 has 8conventional zones.
Specifications
Supply voltage (+10% - 15%) 230 / 110 VAC @ 50 / 60 Hz
Batteries
Capacity 2 x 7.5 Ah
Fuse rating 5 A
Zone
Maximum load 94 mA
Max. number of detectors perzone
20
Maximum zone resistance 44 ohm
Sounders
Maximum load 250 mA
Delay Selectable 0 - 9 min
Relay outputs (excludingsounders)
1 A @ 30 VDC
Extinguishing relay outputs
Maximum load NA
Fuse rating NA
Auxilliary output 250 mA
24 VDC Resetable output
Maximum load 100 mA
Reset time 3 s
Environment
Working temperature -5 °C to +40 °C
Relative humidity 95 % (non condensing)
IP rating IP30
Physical characteristics
Size (mm) 420 (w) x 335 (h) x 110 (d)
Weight (without batteries) 6.2 kg
Ordering Information
Conventional fire panel with 8 fire alarm zonesNK708
Modern, attractive designE
Microprocessor-controlledE
From 2 up to 16-zonesE
EN54 approvedE
2 User access levelsE
2 Monitored sounder outputsE
One-man test capabilityE
24 Volt resetable outputE
External 'Class Change' facilityE
Alarm output with potential free relayE
Common fault output with potential free relay E
External watchdogE
Active end-of-line supportE
Addional optional modules with supervised or relayoutputs
E
Conventional Fire Systems
Page : 9
NK712Conventional fire panel with 12 fire alarm zones
The NK700 series of conventional fire alarm and extinguishing controlpanels is the ideal solution for small to medium-sized installations. Verypowerful and cost-effective, they are extremely simple to install anduse due to their ergonomic, advanced design. The NK712 has 12conventional zones.
Specifications
Supply voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 Hz
Batteries
Capacity 2 x 7.5 Ah
Fuse rating 5 A
Zone
Maximum load 94 mA
Max. number of detectors perzone
20
Maximum zone resistance 44 ohm
Sounders
Maximum load 250 mA
Delay Selectable 0 - 9 min
Relay outputs (excludingsounders)
1 A @ 30 VDC
Extinguishing relay outputs
Maximum load NA
Fuse rating NA
Auxilliary output 250 mA
24 VDC Resetable output
Maximum load 100 mA
Reset time 3 s
Environment
Working temperature -5 °C to +40 °C
Relative humidity 95 % (non condensing)
IP rating IP30
Physical characteristics
Size (mm) 420 (w) x 335 (h) x 110 (d)
Weight (without batteries) 6.2 kg
Ordering Information
Conventional fire panel with 12 fire alarm zonesNK712
Modern, attractive designE
Microprocessor-controlledE
From 2 up to 16-zonesE
EN54 approvedE
2 User access levelsE
2 Monitored sounder outputsE
One-man test capabilityE
24 Volt resetable outputE
External 'Class Change' facilityE
Alarm output with potential free relayE
Common fault output with potential free relay E
External watchdogE
Active end-of-line supportE
Addional optional modules with supervised or relayoutputs
E
Conventional Fire Systems
Page : 10
NK716Conventional fire panel with 16 fire alarm zones
The NK700 series of conventional fire alarm and extinguishing controlpanels is the ideal solution for small to medium-sized installations. Verypowerful and cost-effective, they are extremely simple to install anduse due to their ergonomic, advanced design. The NK716 has 16conventional zones.
Specifications
Supply voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 Hz
Batteries
Capacity 2 x 7.5 Ah
Fuse rating 5 A
Zone
Maximum load 94 mA
Max. number of detectors perzone
20
Maximum zone resistance 44 ohm
Sounders
Maximum load 250 mA
Delay Selectable 0 - 9 min
Relay outputs (excludingsounders)
1 A @ 30 VDC
Extinguishing relay outputs
Maximum load NA
Fuse rating NA
Auxilliary output 250 mA
24 VDC Resetable output
Maximum load 100 mA
Reset time 3 s
Environment
Working temperature -5 °C to +40 °C
Relative humidity 95 % (non condensing)
IP rating IP30
Physical characteristics
Size (mm) 420 (w) x 335 (h) x 110 (d)
Weight (without batteries) 6.2 kg
Ordering Information
Conventional fire panel with 16 fire alarm zonesNK716
Modern, attractive designE
Microprocessor-controlledE
From 2 up to 16-zonesE
EN54 approvedE
2 User access levelsE
2 Monitored sounder outputsE
One-man test capabilityE
24 Volt resetable outputE
External 'Class Change' facilityE
Alarm output with potential free relayE
Common fault output with potential free relay E
External watchdogE
Active end-of-line supportE
Addional optional modules with supervised or relayoutputs
E
Conventional Fire Systems
Page : 11
NK703Conventional extinguishing control panel with 3 zones
The NK703 conventional fire alarm and extinguishing control panels isthe ideal solution for small to medium-sized installations. Very powerfuland cost-effective, they are extremely simple to install and use due totheir ergonomic, advanced design. It has 1 double-knock extinguisingarea consisting of two fire zones, and 1 free fire detection zone.
Specifications
Supply voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 Hz
Batteries
Capacity 2 x 7 Ah
Fuse rating 2 A
Zone
Maximum load 94 mA
Max. number of detectors perzone
20
Maximum zone resistance 44 ohm
Sounders
Maximum load 250 mA
Delay Selectable 0 - 9 min
Relay outputs (excludingsounders)
1 A @ 30 VDC
Extinguishing relay outputs
Maximum load 250 mA
Fuse rating 0.3 A
Auxilliary output 250 mA
24 VDC resetable ouput
Maximum load 100 mA
Reset time 3 s
Environment
Working temperature -5 °C to +40 °C
Relative humidity 95 % (non condensing)
IP rating IP30
Physical characteristics
Size (mm) 420 (w) x 335 (h) x 110 (d)
Weight (without batteries) 6.2 kg
Ordering Information
Conventional extinguishing control panel with 3 zonesNK703
Modern, attractive designE
Microprocessor controlledE
3 zone (1 ext. area) and 6 zone (2 ext. areas) availableE
Automatic extinguishing agent release controlE
2 Access levelsE
Supervised general sounder outputE
Supervised extinguishing inputs and outputsE
One-man test capabilityE
24 Volt resetable outputE
External 'class change' facilityE
Alarm output with potential free relayE
General fault output with potential free relay E
External watchdogE
Conventional Fire Systems
Page : 12
NK706Conventional extinguishing control panel with 6 zones
The NK706 conventional fire alarm and extinguishing control panels isthe ideal solution for small to medium-sized installations. Very powerfuland cost-effective, they are extremely simple to install and use due totheir ergonomic, advanced design. It has 2 double-knock extinguisingareas consisting of two fire zones each, and 2 free fire detection zones.
Specifications
Supply voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 Hz
Batteries
Capacity 2 x 7 Ah
Fuse rating 2 A
Zone
Maximum load 94 mA
Max. number of detectors perzone
20
Maximum zone resistance 44 ohm
Sounders
Maximum load 250 mA
Delay Selectable 0 - 9 min
Relay outputs (excludingsounders)
1 A @ 30 VDC
Extinguishing relay outputs
Maximum load 250 mA
Fuse rating 0.3 A
Auxilliary output 250 mA
24 VDC resetable ouput
Maximum load 100 mA
Reset time 3 s
Environment
Working temperature -5 °C to +40 °C
Relative humidity 95 % (non condensing)
IP rating IP30
Physical characteristics
Size (mm) 420 (w) x 335 (h) x 110 (d)
Weight (without batteries) 6.2 kg
Ordering Information
Conventional extinguishing control panel with 6 zonesNK706
Modern, attractive designE
Microprocessor controlledE
3 zone (1 ext. area) and 6 zone (2 ext. areas) availableE
Automatic extinguishing agent release controlE
2 Access levelsE
Supervised general sounder outputE
Supervised extinguishing inputs and outputsE
One-man test capabilityE
24 Volt resetable outputE
External 'class change' facilityE
Alarm output with potential free relayE
General fault output with potential free relay E
External watchdogE
Conventional Fire Systems
Page : 13
RB404Relay module, 4 potential free relays for NK700/Fx400 fire panels
The RB404 relay expander module provides 4 additional voltage freerelays on the GE Security NK700/FP400/FEC400 conventional firepanels ranges. It allows for these relays to be allocated to individualdetection zones, or for programming the activation of different relaysdepending on the status of one or more zones. Up to 4 of thesemodules may be used on every fire panel.
Specifications
Relay rating
Voltage 250 VAC / 30 VDC
Current 10 A
Delay setting 0 to 9 minutes
Ordering Information
Relay module, 4 potential free relays for NK700/Fx400 fire panelsRB404
4 Potential free relaysE
Up to 4 modules may be housed inside the fire panelcabinet
E
Programmable with basic boolen functionsE
Power supplied from fire panel busE
Output delay setting per relayE
Conventional Fire Systems
Page : 14
SB404Relay module, 4 supervised relays for NK700/Fx400 fire panels
The SB404 expander module provides 4 additional supervised relaysthat provide 24 VDC outputs on the GE Security NK700/FP400/FEC400conventional fire panels ranges. These relays may be configured topower sounders or as standard 24 VDC supervised outputs for otherdevices. Relays may be allocated to individual detection zones, or forprogramming the activation of different relays depending on the statusof one or more zones. Up to 4 of these modulesmay be used on every fire panel.
Specifications
Auxiliary supply 24 VDC
Relay Rating
Voltage 250 VAC / 30 VDC
Current 5 A
Delay setting 0 to 9 minutes
Ordering Information
Relay module, 4 supervised relays for NK700/Fx400 fire panelsSB404
4 Supervised relaysE
Up to 4 modules may be housed inside the fire panelcabinet
E
Programmable with basic boolen functionsE
Output delay setting per relayE
Configurable for sounder control or as supervisedoutputs
E
Conventional Fire Systems
Page : 15
EOL-ACTActive end-of-line device for use with FP400/KL700 fire panels
The EOL-ACT is designed for use with the NK700/FP400 fire panels fromGE-Interlogix. It is an active end-of-line device to allow the monitoringof a conventional zone through a diode base (such as the KZ705D).
Ordering Information
Active end-of-line device for use with FP400/KL700 fire panelsEOL-ACT
SmallE
Easy to installE
Accessories
Page : 16
KLBlack-SBlack front panel cover (small footprint)
The KLBeige-S is a beige coloured, front panel housing lid for theFP200/NKB600, FP402 and FP404/NK702 and NK704 series fire panelsfrom GE Security. It allows the user to change the facure colour of thepanel for colour matching or renewal in case of damage.
Ordering Information
Black front panel cover (small footprint)KLBlack-S
Customisation of panel colour schemeE
Easy replacementE
KLBlack-BBlack front panel cover (large footprint)
The KLBlack-B is a black coloured, front panel housing lid for the FP408,FP412 and FP416/NK708, NK712 and NK716, the FEC400/NK703 andNK706, as well the FP1500/KSA701 series fire panels and repeatersfrom GE Security. It allows the user to change the facure colour of thepanel for colour matching or renewal in case of damage.
Ordering Information
Black front panel cover (large footprint)KLBlack-B
Customisation of panel colour schemeE
Easy replacementE
Addressable Fire Systems
Page : 17
KSA701-1Analogue addressable fire detection panel - 1 loop
The KSA701 analogue addressable fire alarm control panel is the idealsolution for small to medium-sized installations. Very powerful andcost-effective, it is extremely simple to install and use due to itsergonomic, advanced design. The panel is supplied in an elegant,high-quality, conveniently sized, heavy-duty enclosure. The cabinetallows for enough space for the batteries for the system to be housedinside the cabinet. The KSA701 is fully compatible with the Kilsen 700Aseries detectors and KAL400 series accessories.
Specifications
Supply voltage 110/230 VAC @ 50 Hz (+10% -15%)
Current consumption
(no devices connected) 175 mA Quiest. / 241 mA Alarm
Batteries
Capacity 2 x 12 V - 7 AH (SLA type)
Fuse rating 3 A
Charger (Temp. comp. -3 V /°C)
350 mA @ 27.6 VDC @ 20 °C
Loop characteristics per loop
Capacity 250 addresses
Maximum load 400 mA / 26 VDC to 32 VDC
Maximum electricalcharacteristics
44 Ohm / 500 nF
Sounders (reverse polaritysupervision)
Maximum load (2 Outputs) 250 mA each / 18 to 24 VDC
Delays (adjustable in 10 sintervals)
10 to 600 seconds
Relay outputs (potential free) 1 A @ 30 VDC
24 V Auxiliary output
Maximum load 250 mA @ 18 VDC to 28 VDC
Environment
Working temperature -5°C to +40 °C
Relative humidity(non-condensing)
0-95%
IP rating IP30
Physical characteristics
Size 420 mm (w) x 335 (h) x 110 (d)
Weight (without batteries) 6.2 kg
Ordering Information
Analogue addressable fire detection panel - 1 loopKSA701-1
4 x 40 characters LCD displayE
20 Display zonesE
EN54 compliant with approvals pendingE
2 User access levelsE
2 Monitored sounder outputsE
2 Programmable voltage free relaysE
24 Volt auxiliary outputE
I/O programming capabilities with Boolean functionsE
Day/night sensitivity settingsE
Coincidence within zonesE
Upload/download and graphic PC softwareE
Panel networkingE
Installation test capabilityE
Addressable Fire Systems
Page : 18
KSA701-2Analogue addressable fire detection panel - 2 loops
The KSA701 analogue addressable fire alarm control panel is the idealsolution for small to medium-sized installations. Very powerful andcost-effective, it is extremely simple to install and use due to itsergonomic, advanced design. The panel is supplied in an elegant,high-quality, conveniently sized, heavy-duty enclosure. The cabinetallows for enough space for the batteries for the system to be housedinside the cabinet. The KSA701 is fully compatible with the Kilsen 700Aseries detectors and KAL400 series accessories.
Specifications
Supply voltage 110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)
Current consumption
(no devices connected) 175 mA Quiescent / 241 mA in alarm
Batteries
Capacity 2 x 12 V - 7 AH (SLA type)
Fuse rating 3 A
Charger rating (Temp.compensated -3 V / °C)
350 mA @ 27.6 VDC @ 20 °C
Loop characteristics per loop
Capacity 250 addresses
Maximum load 400 mA / 26 VDC to 32 VDC
Maximum electricalcharacteristics
44 Ohm / 500 nF approximately 2 km of 1.5 mm2diameter cable
Sounders (reverse polaritysupervision)
Maximum load 250 mA each (2 Sounder outputs available) / 18 VDCto 24 VDC
Delays (software adjustable in10 second intervals)
10 to 600 seconds
Relay outputs (potential free) 1 A @ 30 VDC
24 V Auxiliary output
Maximum load 250 mA @ 18 VDC to 28 VDC
Environment
Working temperature -5°C to +40 °C
Relative humidity(non-condensing)
0-95%
IP rating IP30
Physical Characteristics
Size 420 mm (w) x 335 (h) x 110 (d)
Weight 6.2 kg without batteries / 10.7 kg with 2 x 7 Ahbatteries
Ordering Information
Analogue addressable fire detection panel - 2 loopsKSA701-2
4 x 40 characters LCD displayE
20 Display zonesE
EN54 compliant with approvals pendingE
4 User access levelsE
2 Monitored sounder outputsE
2 Programmable voltage free relaysE
24 Volt auxiliary outputE
I/O programming capabilities with Boolean functionsE
Day/night sensitivity settingsE
Coincidence within zonesE
Upload/download and graphic PC softwareE
Panel networkingE
Installation test capabilityE
Addressable Fire Systems
Page : 19
NC785RS485 expansion kit for KSA701/FP1500 fire panels
The NC785 RS485 expander allows for an easy upgrade to theKSA701/FP1500 series addressable fire panels. Each module adds anadditional industry standard RS485 communication port to the panel.This port could be used for communications with other network nodesin the fire panel network.
Specifications
Number of ports 1
Communications medium RS485
Technical specifications
Maximum cable length 1200 m
Communication speed 9600 baud
Cable CAT5 - twisted with screen
Termination resistance 150 Ohm
Ordering Information
RS485 expansion kit for KSA701/FP1500 fire panelsNC785
Industry standard RS485 communicationsE
No hardware configuration requiredE
Addressable Fire Systems
Page : 20
KSA701RKSA701 Series LCD Repeater (mains powered)
The KSA701R repeater allows the user to monitor and control panelsconnected to the KSA700 fire panel network via and RS485 link. Itdisplays 20 zones in alarm and fault on the face of the panel, whilst allsystem messages are displayed on the easy to read, LCD display.
Specifications
Supply voltage
AC version 110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)
DC version 24 VDC
Current consumption 175 mA Quiescent / 200 mA in alarm
Battery charger (AC version only)
Capacity 2 x 12 V - 7 AH (SLA type)
Fuse rating 3 A
Charger rating 350 mA @ 27.6 VDC @ 20 °C (Temperaturecompensated -3 V / °C)
Environment
Working temperature -5 °C to +40 °C
Relative humidity 95% (non condensing)
IP rating IP30
Physical characteristics
Size 420 mm (w) x 335 (h) x 110 (d)
Weight 6.2 kg without batteries / 10.7 kg with 2 x 7 Ahbatteries
Communication ports RS232 and RS485 standard
Ordering Information
KSA701 Series LCD Repeater (mains powered)KSA701R
Modern, attractive designE
4 x 40 characters LCD displayE
20 Display zonesE
3 User access levelsE
24 VDC or 230 VAC models availableE
Panel networkingE
Full system controlE
Addressable Fire Systems
Page : 21
KSA701R-24KSA701 Series LCD Repeater (24VDC powered)
The KSA701R repeater allows the user to monitor and control panelsconnected to the KSA700 fire panel network via an RS485 link. Itdisplays 20 zones in alarm and fault on the face of the panel, whilst allsystem messages are displayed on the easy to read, LCD display.
Specifications
Supply voltage
AC version 110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)
DC version 24 VDC
Current consumption 175 mA Quiescent / 200 mA in alarm
Battery charger (AC version only)
Capacity 2 x 12 V - 7 AH (SLA type)
Fuse rating 3 A
Charger rating 350 mA @ 27.6 VDC @ 20 °C (Temperaturecompensated -3 V / °C)
Environment
Working temperature -5 °C to +40 °C
Relative humidity 95% (non condensing)
IP rating IP30
Physical characteristics
Size 420 mm (w) x 335 (h) x 110 (d)
Weight 6.2 kg without batteries / 10.7 kg with 2 x 7 Ahbatteries
Communication ports RS232 and RS485 standard
Ordering Information
KSA701 Series LCD Repeater (24VDC powered)KSA701R-24
Modern, attractive designE
4 x 40 characters LCD displayE
20 Display zonesE
3 User access levelsE
24 VDC or 230 VAC models availableE
Panel networkingE
Full system controlE
Addressable Fire Systems
Page : 22
KSA705Analogue addressable fire panel (expandable to 5 loops)
The KSA700 Series analogue addressable fire panels offer leading-edgetechnology for the control of analogue addressable fire detectiondevices. Their unique user-friendly programming facilitate the idealcontrol environment for either simple or complex fire systems.
Specifications
Supply voltage 230 VAC @ 50 Hz (+10% -15%)
Current consumption
(no devices connected) 175 mA Quiest. / 241 mA Alarm
Batteries
Capacity 2 x 12 V - 6 AH (SLA type)
Fuse rating 4 A
Charger (Temp. comp. -3 V /°C)
350 mA @ 27.6 VDC @ 20 °C
Loop characteristics per loop
Capacity 250 addresses
Maximum load 400 mA / 26 VDC to 32 VDC
Maximum electricalcharacteristics
44 Ohm / 500 nF
Sounders (reverse polaritysupervision)
Maximum load (2 Outputs) 250 mA each / 18 to 24 VDC
Delays (adjustable in 10 sintervals)
10 to 600 seconds
Relay outputs (potential free) 1 A @ 30 VDC
24 V Auxiliary output
Maximum load 800 mA @ 18 to 28 VDC
Environment
Working temperature -5 °C to +40 °C
Relative humidity 95% (non condensing)
IP rating IP41
Physical characteristics
Size 480 mm (w) x 455 (h) x 140 (d)
Weight (without batteries) 13.6 kg
Ordering Information
Analogue addressable fire panel (expandable to 5 loops)KSA705
4-line, 40-character LCD displayE
Panel networking capabilityE
Graphic monitoring softwareE
Windows based up/download programming softwareE
Remote programming and maintenance via modemand TCP/IP
E
Repeater facilitiesE
Powerful auto-configuration functionsE
Simple program options with on-screen menu selectionE
EN54 compliantE
Addressable Fire Systems
Page : 23
KSA705PAnalogue addressable fire panel with printer (expandable to 5 loops)
The KSA700 Series analogue addressable fire panels offer leading-edgetechnology for the control of analogue addressable fire detectiondevices. Their unique user-friendly programming facilitate the idealcontrol environment for either simple or complex fire systems. TheKSA705P offers an additional internal printer facility.
Specifications
Supply voltage 230 VAC @ 50 Hz (+10% -15%)
Current consumption (no devicesconnect)
175 mA Quiescent / 241 mA in alarm
Batteries
Capacity 2 x 12 V - 6 AH (SLA type)
Fuse rating 4 A
Charger (Temp. comp. -3 V /°C)
350 mA @ 27.6 VDC @ 20 °C
Loop characteristics per loop
Capacity 250 addresses
Maximum load 400 mA / 26 VDC to 32 VDC
Maximum electricalcharacteristics
44 Ohm / 500 nF approximately 2 km of 1.5 mm2diameter cable
Sounders (reverse polaritysupervision)
Maximum load 250 mA each (2 Sounder outputs available) / 18 VDCto 24 VDC
Delays (adjustable in 10 sintervals)
10 to 600 seconds
Relay outputs (potential free) 1 A @ 30 VDC
24 V Auxiliary output
Maximum load 800 mA @ 18 VDC to 28 VDC
Environment
Working temperature -5 °C to +40 °C
Relative humidity 95% (non condensing)
IP rating IP41
Physical characteristics
Size 480 mm (w) x 455 (h) x 140 (d)
Weight 13.6 kg without batteries / 21.6 kg with 2 x 7 Ahbatteries
Ordering Information
Analogue addressable fire panel with printer (expandable to 5 loops)KSA705P
4-line, 40-character LCD displayE
Panel networking capabilityE
Graphic monitoring softwareE
Windows based up/download programming softwareE
Remote programming and maintenance via modemand TCP/IP
E
Repeater facilitiesE
Powerful auto-configuration functionsE
Simple program options with on-screen menu selectionE
EN54 compliantE
Addressable Fire Systems
Page : 24
KAL701Loop driver module for KSA702/705 control panels
The KAL701 1 loop expander allows for an easy upgrade to the KSA702and KSA705 analalogue addressable fire panels. Each module consistof a simple plug in card and requires no additional settings orconnections for full functionality. The KAL701 has loop isolatorssupplied on both drivers and allows full class-A loop functionality withup to 250 device addresses.
Specifications
Number of loops 1
Loop characteristics
Capacity 250 addresses
Maximum load 400 mA / 26 VDC to 32 VDC
Maximum electricalcharacteristics
44 Ohm / 500 nF
Maximum loop length 2 km
Ordering Information
Loop driver module for KSA702/705 control panelsKAL701
Expands the loop capabailities of the KSA702 andKSA705
E
Allows for the connection of an additional 250 devicesper unit
E
Two isolated drivers support full class-A operationE
No hardware configuration requiredE
KAL732RS232 communications module for KSA702/5 control panels
The KAL732 RS232 expander allows for an easy upgrade to the KSA702and KSA705 analalogue addressable fire panels. Each module adds anadditional industry standard RS232 communication port to the panel.This port could be used for communications with a PC or forconnections to a printer or modem.
Specifications
Number of ports 1
Communications medium RS232
Technical specifications
Maximum cable length 15 m
Communication speed 9600 baud
Cable 3 core with screen
Ordering Information
RS232 communications module for KSA702/5 control panelsKAL732Industry standard RS232 communicationsE
No hardware configuration requiredE
Addressable Fire Systems
Page : 25
KAL785RS485 communications module for KSA702/5 control panels
The KAL785 RS485 expander allows for an easy upgrade to the KSA702and KSA705 analalogue addressable fire panels. Each module adds anadditional industry standard RS485 communication port to the panel.This port could be used for communications with other network nodesin the fire panel network.
Specifications
Number of ports 1
Communications medium RS485
Technical specifications
Maximum cable length 1200 m
Communication speed 9600 baud
Cable CAT5 - twisted with screen
Termination resistance 150 Ohm
Ordering Information
RS485 communications module for KSA702/5 control panelsKAL785
Industry standard RS485 communicationsE
No hardware configuration requiredE
KAL791Protocol Converter RS232/485 - Kilsen / Johnsson Control
The KAL791 is a protocol converter for the integration of Kilsen KSA700analogue fire alarm systems into Johnsson Controls buildingmanagement systems. It requires a 24 VDC supply from an auxiliarypower supply source.
Specifications
Supply Voltage 24 VDC
Current Consumption
260 mAEnvironment
Working Temperature -5°C to +40 °C
Relative Humidity(non-condensing)
0-95%
IP Rating IP41
Physical Characteristics
Size 390 mm (w) x 420 (h) x 135 (d)
Weight 9.3 kg
Ordering Information
Protocol Converter RS232/485 - Kilsen / Johnsson ControlKAL791 RS232 communications module for KSA702/5 control panelsKAL732RS485 communications module for KSA702/5 control panelsKAL785
RS232 or RS485 port optionsE
Seemless integration with no additional programmingon the fire system
E
24 VDC SupplyE
Addressable Fire Systems
Page : 26
KSA1204Analogue fire panel, 2 loops upgradable to 4, 64 display zones
The KSA1204 allows for 2 addressble fire panel loops and 64 displayzones.
Specifications
Supply voltage 230 VAC (+10/-15%) 50 Hz
Supply current (max) 1.5 A
Min. supply current @ 24 VDC 0.2 A
Battery charger rating @ 27.6VDC
1.6 A
Total supply rating @ 27.6 VDC 2.5 A
Relay rating @ 24 VDC 2 A
Weight (no batteries) 8 kg
Dimensions (H x W x D) 440 x 444 x 125 mm
Ordering Information
Analogue fire panel, 2 loops upgradable to 4, 64 display zonesKSA1204 2-loop extension board for 1200/2000 series fire panelsLC1502LON700 driver for FP1200 / FP2000LON2000ARCNET RS485 network card with single RS485 interfaceNC2011ARCNET network card with single optical interface boardNC2051Dongle for 1200 series panel networkingNET1200Relay extension board for 1200/2000 series fire panelsRB2016 Modem kitMOD2000 Programming and configuration softwarePCC2000Maintenance and support software with copy protection keyPCM2000
One man maintenanceE
Maintenance warningE
Soak testE
On-line diagnostics and statisticsE
Power supply for 72 hour autonomyE
Floating background compensationE
Coincidence within and in between zonesE
Start-up default modeE
Upload/download configuration facilities with PCE
I/O programming including Boolean functionsE
EN54 p2 & 4 and VDS approvedE
2 or 4 class A loopsE
Addressable Fire Systems
Page : 27
KSA1208Addressable fire panel, 2-8 loops, 64-255 display zones upgradable
A versatile, powerful addressable fire panel, 2 to 8 loops, 16 to 64displayed zones with extensive I/O features. The fire panel can operatewithin a 31 panel network and can communicate with global repeatersand PC graphics. It supports all the 700 series LON devices andrepeaters using a seperate two wire bus. It is truly user-friendly andprovides a generous 8 x 40 backlit graphic display. I/O control is donevia powerful boolean I/O programing. Extensive maintenance featuresare provided standard. The KSA1200 series supports 1500 seriessensors and 400 series I/O units.
Specifications
Supply voltage 1 190 - 270 V ac
40 - 60 Hz160 VA max.
Supply voltage 2 21 - 27 V dc
Current consumption
Quiescent @ 24 V dc (equippedloop)
800 mA
Alarm current @ 24 V dc 1 A
Available auxiliary current inalarm
3 A
Battery charger rating @ 27.5 Vdc
3 A
Total supply rating @ 27.5 V dc 4 A
Relay rating @ 24 V dc 2 A
Weight (no batteries) 15 kg
Dimensions (mm) (H x W x D) 804 x 441 x 109
Ordering Information
Addressable fire panel, 2-8 loops, 64-255 display zones upgradableKSA1208
One man maintenanceE
Graphic maintenanceE
Maintenance warningE
Service reminder signalE
Soak testE
On-line diagnostics and statisticsE
Floating background compensationE
Day/night sensitivity settingE
Coincidence within and in between zonesE
Automatic timed and manual on/off zonesE
Start-up default modeE
Service switchE
Upload/download, remote maintenance and graphic PCsoftware
E
I/O programming including Boolean functionsE
ARCNET panel networkingE
EN54 approved; certified Bosec, VdS, NFA2PE
Networkable "black box" and "global zone" systemE
Full range of repeater panelsE
Full range of LON devicesE
Addressable Fire Systems
Page : 28
KSA1264RRepeater / emulator with 64 zone indications
A repeater / emulator with 64 displayed fire and fault zones, used inKSA1200 networked systems. The repeater is connected on the arcnetnetwork and can operate in a local or global repeater mode. An 80 x 40backlit graphic display and full indication and control keyboard isprovided standard.
Specifications
Supply voltage 230 Vdc
Current consumption 300 mA max
Weight 15 kg
Dimensions (mm) (H x W x D) 804 x 441 x 109
Ordering Information
Repeater / emulator with 64 zone indicationsKSA1264R
8 x 40 character graphic displayE
Arcnet network connection to KSA1200 series firepanels
E
Global repeater functionE
Comprehensive control and display functionsE
Emulation functionE
64 zones fire and fault displayedE
230 VAC operationE
Addressable Fire Systems
Page : 29
KSA12255RGlobal zone repeater, 64 zones expandable up to 255
A repeater/emulator with 64 fire and fault zones, expandable to 255,used in 1200/2000 series networked systems. The repeater isconnected on the arcnet network and can operate in a local or globalrepeater mode. An 80 x 40 character, backlit graphic display and fullindication and control keyboard is provided standard.
Specifications
Supply voltage 1 190 - 270 VAC
40- 60 Hz160 VA max.
Current consumption
Quiescent 800 mA
Alarm current @ 24 V dc 1 A
Available auxiliary current inalarm
3 A
Battery charger rating @ 27.5V dc
3 A
Total supply rating 4 A
Weight (no batteries) 15 kg
Dimensions (mm H x W x D) 804 x 441 x 109
Ordering Information
Global zone repeater, 64 zones expandable up to 255KSA12255R LON700 driver for FP1200 / FP2000LON2000RS485 network extension boardNE2011Fibre optic network extension boardNE205164-zone LED extension fire and fault LEDZE2064
On-line diagnostics and statisticsE
Upload/download, remote maintenance and graphic PCsoftware
E
I/O programming including Boolean functionsE
ARCNET panel networkingE
Full range of 700 series LON devicesE
Addressable Fire Systems
Page : 30
LC15022-loop extension board for 1200/2000 series fire panels
The LC1502 is a 2-loop extension board for 1200/2000 series firepanels. It allows for 2 additional class-A loops to be inserted into thefire panel, and supports up to 250 addressable loop devices per loop.
Specifications
Current consumption
Quiescent @ 24 VDC (Fullyequipped loop)
+ 150 mA (252 detectors)
Ordering Information
2-loop extension board for 1200/2000 series fire panelsLC1502
2 Class-A loopsE
Up to 250 devices per loop (protocol dependent)E
Supports various detector protocolsE
No hardware address requiredE
LON2000LON700 driver for FP1200 / FP2000
FP1200 / FP2000 seriesA LON700 driver that connects FP1200 / FP2000 fire panels to LON700devices
Ordering Information
LON700 driver for FP1200 / FP2000LON2000
Addressable Fire Systems
Page : 31
LON2000RLON driver for FP1200/2000 - closed loop systems
The LON2000R is a LON700 driver that connects 1200/2000 series firepanels to LON700 series devices on a closed loop, CLASS-A LON700network.
Ordering Information
LON driver for FP1200/2000 - closed loop systemsLON2000R
NC2011ARCNET RS485 network card with single RS485 interface
The NC2011 is an interface board to connect an RS485 copper networkdirectly into the 1200/2000 series fire panels. It is supplied with oneNE2011 pre installed.
Ordering Information
ARCNET RS485 network card with single RS485 interfaceNC2011RS485 network extension boardNE2011
Addressable Fire Systems
Page : 32
NC2051ARCNET network card with single optical interface board
The NC2051 is an interface board to connect a fiber optic networkdirectly into the 1200/2000 series fire panels. It is supplied with oneNE2051 pre installed.
Ordering Information
ARCNET network card with single optical interface boardNC2051Fibre optic network extension boardNE2051
NE2011RS485 network extension board
The NE2011 is a RS485 network extension board for the NC2011 toallow dual bus and closed ring networks.
Ordering Information
RS485 network extension boardNE2011
Addressable Fire Systems
Page : 33
NE2051Fibre optic network extension board
FP1200 / FP2000 seriesAn extension board for the NC2051 to allow a fibre optic ring bus
Ordering Information
Fibre optic network extension boardNE2051
PR2000Internal printer
The PR2000 is a panel mount, 40-column dot matrix printer to be usedwith the 1200/2000 series fire panels. It is supplied with all necessaryaccesories to allow easy installation into cabinets that allow for thisoption.
Ordering Information
Internal printerPR2000
Addressable Fire Systems
Page : 34
RB2016Relay extension board for 1200/2000 series fire panels
The RB2016 is an extension board for 1200/2000 series fire panels. Itallows for up to 18 additional potential free relays to be added into thefire panel cabinet. Depending on the size and hardware configurationof the panel, up to 4 RB2016s may be included in any panel.
Specifications
Relay Contact Rating 1 A @ 30 VDC / 0.3 A @ 110 VDC / 0.3 A @ 125 VAC
Ordering Information
Relay extension board for 1200/2000 series fire panelsRB2016
Up to 18 potential free relay outputsE
No hardware address requiredE
ZE206464-zone LED extension fire and fault LED
The ZE2064 allows the extension of the zones of the Fx2x128 andFx2x255 fire panels and repeaters by 64 additional zones.
Ordering Information
64-zone LED extension fire and fault LEDZE2064
LON700 Devices
Page : 35
FRL700LCD repeater
The LON700 LCD repeater is a smart and compact, cost-effectivesolution for fire panel repeaters. It is also available as an FBP700 firebrigade panel for Dutch and Scandinavian norms.
Specifications
Dimensions (l x w x d) 240 x 320 x 60 mm
Weight 1.5 kg
Operating temp °C -5°C to +40°C
Operating voltage 15 - 30 VDC
Current consumption
Max. quiesent 100 mA
Bus Connection two wire LON700
Bus Cable CAT 5
Total number of repeaters
700/1200/2000 Series 15
Ordering Information
LCD repeaterFRL700
2 wire connection between fire panel and repeatersE
Up to 1500 metre bus lengthE
24 Volt power supplyE
Cost effective repeater solutionsE
Easily installed, simple operationE
4 x 20 charater LCD display, common LED's, pushbutton control
E
LON700 moduleE
LON700 Devices
Page : 36
NA704LON700 network amplifier (4 way)
The NA704 is an interface board to allow an extension of the LON700network above its normal limitations. It acts as a network amplifierallowing for reconstruction and re-transmission of the LON700 signal,as well as allowing for T-offs of the network as required.
Ordering Information
LON700 network amplifier (4 way)NA704 LON700 driver for the NC771 and NA704NE771Fibre optic network extension boardNE2051
NC700LON700 interface board
The NC700 is an interface board to connect a LON700 bus from a firepanel to a FB7xx 'black box'.
Ordering Information
LON700 interface boardNC700
LON700 Devices
Page : 37
NC771LON700 closed loop communication board (no driver)
The NC771 is an interface board to connect a LON bus from a firepanel to a FB7xx 'black box' panel. It allows for full Class-A typeLON700 networks.
Ordering Information
LON700 closed loop communication board (no driver)NC771 LON700 driver for the NC771 and NA704NE771Fibre optic network extension boardNE2051
NE771LON700 driver for the NC771 and NA704
The NE771 is a LON700 network extension board to allow dual bus andclosed ring networks on the NC771 and the NA771.
Ordering Information
LON700 driver for the NC771 and NA704NE771
LON700 Devices
Page : 38
OCB724LON700 output board with 24 open collector outputs
The OCB724 is a 24 way open collector board used in a LON700system.
Ordering Information
LON700 output board with 24 open collector outputsOCB724
PS700Plug-in power supply 3.5 A
The PS700 power supply can be used to extend the power output inLON700 systems.
Ordering Information
Plug-in power supply 3.5 APS700
LON700 Devices
Page : 39
RB708LON700 output board with 8 relays
The RB708 is an eight way relay board used in LON700 systems.
Specifications
Number of outputs 8
Relay contact rating
Switching current 2A
Switching volage 42V ac/dc
Switching power 60W
Ordering Information
LON700 output board with 8 relaysRB708
SIB716Supervised input board 16 way LON700
The SIB716 is a sixteen way input board used in LON700 systems.
Ordering Information
Supervised input board 16 way LON700SIB716
LON700 Devices
Page : 40
SOB708LON700 output board with 8 supervised outputs
The SOB708 provides eight supervised outputs that can be used inLON700 systems.
Specifications
Number of outputs 8
Output type polarity reversal
End of line resistor 5.6 Kohm
Output current per output 500mA
Total current for all outputs 2A
Open circuit >27 Kohm
Normal 1.2 - 18 Kohm
Short circuit < 470 ohm
Ordering Information
LON700 output board with 8 supervised outputsSOB708
ZI7088 zone input extension board
The ZI708 is an eight zone input expansion board for LON700compatible systems. It allows for the connection of up to 8conventional fire detector zones and is compatible with most industrystandard conventional detectors.
Ordering Information
8 zone input extension boardZI708
Gas Detection
Page : 41
KM260/1R3-03CO detection control panel - 1 Zone (English Version)
The KM-Series CO detection system is designed for applications suchas vehicle parking areas where concentrations of CO may accumulate.The range is compliant with the UNE23.300/84 standard. The KM260/1is a 1 (upgradable to 2) zone control unit, using KM170 detectors.
Specifications
Power supply
Mains supply 230 VAC ±10% 50 Hz
Power consumption 95 W (max)
Zone configuration
Zone input voltage 10-20 VDC/VAC
Sensitiviy 0-300 ppm
Cable requirement 3 core 1.5 mm²
Cable length (max) 350 m
No. of detectors (max) 15
No. of zones (max) 2
Mechanical
Housing (w x h x d) 275 x 335 x 130 mm
Weight 6 kg
Ordering Information
CO detection control panel - 1 Zone (English Version)KM260/1R3-03
Designed according to norm 23300/84E
Miner CDM8001 and CDM8002 standard passwordE
LGAI 154.909 and 96013132 standard certificationE
Easy to useE
Low current consumptionE
Direct reading of measured levelsE
Easy installationE
Extraction relays and alarm outputs per areaE
From 1 to 5 areasE
3-wire systemE
Modular designE
Up to 15 detectors per zoneE
10 seconds response timeE
Elegant designE
Supervision of all zone linesE
Available in various languagesE
Gas Detection
Page : 42
KM260/3R3-03CO detection control panel - 3 Zones (English Version)
The KM-Series CO detection system is designed for applications suchas vehicle parking areas where concentrations of CO may accumulate.The range is compliant with the UNE23.300/84 standard. The KM260/3is a 3 (upgradable to 5) zone control unit, using KM170 detectors.
Specifications
Power supply
Mains supply 230 VAC ±10% 50 Hz
Power consumption 95 W (max)
Zone configuration
Zone input voltage 10-20 VDC/VAC
Sensitiviy 0-300 ppm
Cable requirement 3 core 1.5 mm²
Cable length (max) 350 m
No. of detectors (max) 15
No. of zones (max) 5
Mechanical
Housing (w x h x d) 470 x 335 x 130 mm
Weight 10.2 kg
Ordering Information
CO detection control panel - 3 Zones (English Version)KM260/3R3-03
Designed according to norm 23300/84E
Miner CDM8001 and CDM8002 standard passwordE
LGAI 154.909 and 96013132 standard certificationE
Easy to useE
Low current consumptionE
Direct reading of measured levelsE
Easy installationE
Extraction relays and alarm outputs per areaE
From 1 to 5 areasE
3-wire systemE
Modular designE
Up to 15 detectors per zoneE
10 seconds response timeE
Elegant designE
Supervision of all zone linesE
Available in various languagesE
Gas Detection
Page : 43
KM260EXT3-03CO detection expansion module (English Version)
The KM260 is an expansion module for the KM260-Series CO panelsfrom GE-Interlogix. It allows for an additional monitoring zone to beadded to the control panel, each module allowing for an additional 15sensors to be connected.
Specifications
Power supply
Mains supply 230 VAC ±10% 50 Hz
Power consumption 95 W (max)
Zone configuration
Zone input voltage 10-20 VDC/VAC
Sensitiviy 0-300 ppm
Cable requirement 3 core 1.5 mm²
Cable length (max) 350 m
No. of detectors (max) 15
No. of zones (max) 1
Ordering Information
CO detection expansion module (English Version)KM260EXT3-03 Designed according to norm 23300/84E
Miner CDM8001 and CDM8002 standard passwordE
LGAI 154.909 and 96013132 standard certificationE
Easy to useE
Low current consumptionE
Direct reading of measured levelsE
Easy installationE
Extraction relays and alarm outputs per areaE
3-wire systemE
Up to 15 detectors per zoneE
10 seconds response timeE
Supervision of zone lineE
Available in various languagesE
Gas Detection
Page : 44
KM260CBlanking plate for KM260 panels
The blanking plate is used on KM260 panels during upgrading ofmodules to cover up any unused positions that may exist on the panel.
Ordering Information
Blanking plate for KM260 panelsKM260C
Gas Detection
Page : 45
KM170CO detector with base and mounting supplement
The KM170 detector is specifically designed to react to the presence ofcarbon monoxide. The design complies with the requirements of theUNE 23-300 standard.
Specifications
Sensor type TGS semicondictor
Useful life 4 years
Electrical characteristics
Supply voltage 10 to 20 VDC
Quiescent current 35 mA
Reaction time 10 s
Environmental
Operating temperature 0 °C to +40 °C
Protection index IP205
Mechanical
Size (h x Ø) 81 x 109 mm
Weight 115 g
Material and colour ABS white
Installation
Number of detectors per zone 15
Covarage 300 m²
Ordering Information
CO detector with base and mounting supplementKM170
Complies with the requirements of the UNE23-300standard
E
Microprocessor basedE
Resolution of up to 5 ppmE
Response time of 10 sE
Low current consumptionE
Local status indication of:-Normal operation-50ppm detected-Fault
E
Useful life of up to 4 yearsE
Gas Detection
Page : 46
KZ400Detector base for KL400/KM170 series devices
The KZ400 base is designed to be used with the KL400 series detectors,but may also be used as a substitution base for KM170 CO detectors.
Specifications
Dimensions
Diameter 107 mm
Height 22 mm
Ordering Information
Detector base for KL400/KM170 series devicesKZ400
Polarity sensitiveE
Remote indicator contact availableE
S300Surface mount supplement for KL300/KM170 detectors
The S300 is a base accessory designed for use with the KZ300 andKZ400 detector base. It allows for a surface mount conduit and cableto enter the base from the side. The KZ300 and KZ400 base fits on topof this accessory. The S300 can also be used with KM170 CO detectors.
Specifications
Dimensions
Diameter 107 mm
Height 25 mm
Ordering Information
Surface mount supplement for KL300/KM170 detectorsS300
Surface mount accessory for KZ300E
May be used with KM170 CO DetectorsE
Aspiration Systems
Page : 47
ASD20CAspiration Smoke Detector
The ASD20 Aspiration Smoke Detector consists of an analysis chamberwith one or two smoke detectors, connected to standard 25 mm ØPVC piping. The detectors can be of conventional or analoguetechnology, ionisation or optical.
Specifications
Power supply voltage 24 VDC
Current Consumption
Standby 250 mA
1st alarm 280 mA
2nd alarm 320 mA
Fault 220 mA
Environmental Characteristics
Working temperature -10 to +60°C
Storage temperature -10 to +70°C
Relative humidity <95%
Physical Characteristics
Size 314 x 254 x 115
Weight 4 kg
Colour RAL9999
Material Polycarbonate
Cable input 3 x PG11
Wire cross-section Max. 1.5 mm²
Coverage area per intake 30 m²
Maximum num. of intakes 12
DIN 8062-type PVC pipes Ø25 mm
Useful lifetime of motor 65 000 hours at 40°C
Ordering Information
Aspiration Smoke DetectorASD20C Filter housing for ASD20ASD20FFilter only for ASD20ASD20FIL
Used with conventional or analogue detectorsE
Direct connection to an analogue loop or stand-aloneoperation
E
Alarm 1, alarm 2 and fault relay outputsE
24 VDC power supplyE
Simple and robust architectureE
30 m² coverage per sample intakeE
Standard 25 mm PVC piping systemE
Installation of piping in I-shape and U-shape(symmetrical or assymmetrical)
E
Continuous supervision of pipe flow volumeE
Aspiration Systems
Page : 48
ASD20FFilter housing for ASD20
The ASD20F is an aluminium filter housing for the ASD20 aspirationdetection system. It houses and protects the the air filter, the ASD20FIL,that has to be ordered seperately.
Ordering Information
Filter housing for ASD20ASD20F Filter only for ASD20ASD20FIL
Robust, light weight, aluminium constructionE
Easy to installE
Easy filter replacementE
ASD20FILFilter only for ASD20
Filter only for ASD20 Aspiration Detector.
Ordering Information
Filter only for ASD20ASD20FIL
Conventional Fire Systems
Page : 49
KV210Rate-of-Rise Heat Detector
The KV210 heat detectors are designed to activate when thetemperature exceeds a preset level or when the speed at which thetemperature changes is above a set threshold, even if the fixedactivation temperature point has not been reached. These detectorscomply to the UNE 23-007 part 5 standard.
Specifications
Operating voltage 16 to 28 VDC
Current consumption
Quiescent at 24 VDC < 100 A
Alarm at 24 VDC < 100 mA
Remote alarm output NA
Heat specification UNE 23.007/5 compliant
Working Area 20-30 m²
Installation Height (max.) 6 m
Operating temperature -10 to +60 °C
Storage temperature -10 to +70 °C
Humidity (non-condensing) 0 - 95%
IP rating IP205
Dimensions (h x Ø) 60 mm x 108 mm
Ordering Information
Rate-of-Rise Heat DetectorKV210
Very low standby currentE
Two-wire connectionE
No mechanical parts subject to wear and tearE
Rate-of-rise and thermostaticE
Remote indicator output on KV210PE
Latching alarmE
Compact and water resistant electronicsE
Highly resistant to humidity and corrosionE
Modern and elegant designE
No base requiredE
Excellent price/quality ratioE
Conventional Fire Systems
Page : 50
KV210PRate-of-Rise Heat Detectors with remote indicator output
The KV210 heat detectors are designed to activate when thetemperature exceeds a preset level or when the speed at which thetemperature changes is above a set threshold, even if the fixedactivation temperature point has not been reached. These detectorscomply to the UNE 23-007 part 5 standard. The KV210P has an outputfor a remote indicator.
Specifications
Operating voltage 16 to 28 VDC
Current consumption
Quiescent at 24 VDC < 100 A
Alarm at 24 VDC < 100 mA
Remote alarm output < 100 mA
Heat specification UNE 23.007/5 compliant
Working Area 20-30 m²
Installation Height (max.) 6 m
Operating temperature -10 to +60 °C
Storage temperature -10 to +70 °C
Humidity (non-condensing) 0 - 95%
IP rating IP205
Dimensions (h x Ø) 60 mm x 108 mm
Ordering Information
Rate-of-Rise Heat Detectors with remote indicator outputKV210P
Very low standby currentE
Two-wire connectionE
No mechanical parts subject to wear and tearE
Rate-of-rise and thermostaticE
Remote indicator output on KV210PE
Latching alarmE
Compact and water resistant electronicsE
Highly resistant to humidity and corrosionE
Modern and elegant designE
No base requiredE
Excellent price/quality ratioE
Conventional Fire Systems
Page : 51
KL500Low Profile Ionisation Smoke Detector
The KL500 ionisation smoke detector reacts to the presence of bothvisible and invisible combustion smoke, which makes it ideal for earlyfire detection, even before flames appear.
Specifications
Operating voltage 18 to 28 VDC
Current consumption
Quiescent at 24 VDC 30 mA
Alarm at 24 VDC < 70 mA
Radio-active source Americium 241
Average activity < 1mCi
Remote alarm output < 100 mA
Operating temperature -10 to +60 °C
Storage temperature -10 to +70 °C
Humidity (non-condensing) 0 - 95%
IP rating IP205
Dimensions (h x Ø)
Head 60 mm x 108 mm
Base 24 mm x 103 mm
Coverage 60 - 80 m²
Maximum installation height 12 m
Ordering Information
Low Profile Ionisation Smoke DetectorKL500 Fire detector base for KL500 detectorsKZ500Surface mount supplement for KL300/KM170 detectorsS300 Low current remote LED indicatorPA25/3L
Response to the full range of combustion smokeE
Low standby currentE
No mechanical parts subject to wear and tearE
High luminosity alarm indicatorE
Remote indicator output availableE
Latching alarmE
Two wire connectionE
Highly resistant to humidity and corrosionE
Modern and elegant designE
Easy installationE
More than 90% of materials recyclable (including theradio-active source)
E
Conventional Fire Systems
Page : 52
KZ500Fire detector base for KL500 detectors
The KZ500 is a detecor base for use with the KL500 detectors fromKilsen. It allows for a remote indicator to be connected.
Specifications
Dimensions
Diameter 108 mm
Height 18 mm
Ordering Information
Fire detector base for KL500 detectorsKZ500
Polarity sensitiveE
Remote indicator contact availableE
Conventional Fire Systems
Page : 53
KL700Ionisation detector, conventional
Of outstanding performance, efficiency and durability, the 700 seriesfire detectors are the ideal solution for conventional installations. Theyare designed specifically for use with the Kilsen NKB600, NK600 andNK700 series conventional fire panels, but are also compatible withmost 3rd party industry standard conventional control panels.
Specifications
Operating voltage 18 to 28 VDC
Current consumption
Quiescent at 24 VDC 30 A
Alarm at 24 VDC < 100 mA
Radio-active source Americium 241
Average activity 0.33 +/-0.04 Ci (12.1 +/- 1.5 kBq)
Remote alarm output < 100 mA
Heat specification
Operating temperature -10 to +60 °C
Storage temperature -10 to +70 °C
Humidity (non-condensing) 0 - 95%
IP rating IP43
Number of detectors per zone 20
Recommended protectionresistor
300 ohm
Dimensions (h x Ø)
Head 45 mm x 99 mm
Base 24 mm x 103 mm
Approvals* EN54 (BOSEC)
* Check current status with localoffice
Ordering Information
Ionisation detector, conventionalKL700 Universal fire detector base KZ700Universal fire detector base with earth connectionKZ705Conventional fire detector base with diodeKZ705D Low current remote LED indicatorPA25/3L
Full line consisting of Optical, Ionisation and Heatdetectors
E
An ultra-fine grid prevents the ingress of dust andinsects in smoke detectors
E
Attractive, low-profile designE
EN54 approved *E
Innovative base compensates for uneven surfacesE
Field exchangeable optical chamber for ease ofmaintenance
E
Conventional Fire Systems
Page : 54
KL710Temperature detector (fixed and rate-of-rise), conventional
Of outstanding performance, efficiency and durability, the 700 seriesfire detectors are the ideal solution for conventional installations. Theyare designed specifically for use with the Kilsen NKB600, NK600 andNK700 series conventional fire panels, but are also compatible withmost 3rd party industry standard conventional control panels.
Specifications
Operating voltage 18 to 28 VDC
Current consumption
Quiescent at 24 VDC 70 A
Alarm at 24 VDC < 100 mA
Radio-active source
Average activity
Remote alarm output < 100 mA
Heat specification Max. & ROR to EN54p5
Operating temperature -10 °C to +70 °C
Storage temperature -10 °C to +80 °C
Humidity (non-condensing) 95%
IP rating IP43
Number of detectors per zone 20
Recommended protectionresistor
300 ohm
Dimensions (h x Ø)
Head 45 mm x 99 mm
Base 24 mm x 103 mm
Approvals* EN54 (BOSEC)
* Check current status with localoffice
Ordering Information
Temperature detector (fixed and rate-of-rise), conventionalKL710 Universal fire detector base KZ700Universal fire detector base with earth connectionKZ705Conventional fire detector base with diodeKZ705D Low current remote LED indicatorPA25/3L
Full line consisting of Optical, Ionisation and Heatdetectors
E
An ultra-fine grid prevents the ingress of dust andinsects in smoke detectors
E
Attractive, low-profile designE
EN54 approved *E
Innovative base compensates for uneven surfacesE
Field exchangeable optical chamber for ease ofmaintenance
E
Conventional Fire Systems
Page : 55
KL731Optical detector, conventional (with field exchangeable optical block)
Of outstanding performance, efficiency and durability, the 700 seriesfire detectors are the ideal solution for conventional installations. Theyare designed specifically for use with the Kilsen NKB600, NK600 andNK700 series conventional fire panels, but are also compatible withmost 3rd party industry standard conventional control panels.
Specifications
Operating voltage 9 to 28 VDC
Current consumption
Quiescent at 24 VDC 85 A
Alarm at 24 VDC < 100 mA
Radio-active source
Average activity
Remote alarm output < 100 mA
Heat specification
Operating temperature -10 °C to +70 °C
Storage temperature -10 °C to +70 °C
Humidity (non-condensing) 95%
IP rating IP43
Number of detectors per zone 20
Recommended protectionresistor
300 ohm
Dimensions (h x Ø)
Head 45 mm x 99 mm
Base 24 mm x 103 mm
Approvals* EN54 (BOSEC)
* Check current status with localoffice
Ordering Information
Optical detector, conventional (with field exchangeable optical block)KL731 Replacement Optical Chamber for KL731/A & DP331I/1561 detectorsKOB700 Universal fire detector base KZ700Universal fire detector base with earth connectionKZ705Conventional fire detector base with diodeKZ705DConventional 12 VDC fire detector base with relayKZ705R Low current remote LED indicatorPA25/3L
An ultra-fine grid prevents the ingress of dust andinsects in smoke detectors
E
Attractive, low-profile designE
EN54 approvedE
Innovative base compensates for uneven surfacesE
Field exchangeable optical chamber for ease ofmaintenance
E
Conventional Fire Systems
Page : 56
KL731BOptical detector, conventional - Black
Of outstanding performance, efficiency and durability, the 700 seriesfire detectors are the ideal solution for conventional installations. Theyare designed specifically for use with the Kilsen NKB600, NK600 andNK700 series conventional fire panels, but are also compatible withmost 3rd party industry standard conventional control panels. TheKL731B is a black detector specifically designed for use in falseceilings.
Specifications
Operating voltage 9 to 28 VDC
Current consumption
Quiescent at 24 VDC 85 A
Alarm at 24 VDC < 100 mA
Radio-active source
Average activity
Remote alarm output < 100 mA
Heat specification
Operating temperature -10 °C to +70 °C
Storage temperature -10 °C to +70 °C
Humidity (non-condensing) 95%
IP rating IP43
Number of detectors per zone 20
Recommended protectionresistor
300 ohm
Dimensions (h x Ø)
Head 45 mm x 99 mm
Base 24 mm x 103 mm
Approvals* EN54 (BOSEC)
* Check current status with localoffice
Ordering Information
Optical detector, conventional - BlackKL731B Replacement Optical Chamber for KL731/A & DP331I/1561 detectorsKOB700
An ultra-fine grid prevents the ingress of dust andinsects in smoke detectors
E
Attractive, low-profile designE
EN54 certification marks (*)E
Field exchangable optical chamber for ease ofmaintenance
E
Black colour E
Conventional Fire Systems
Page : 57
KCT731Calibration Tool for KL731/DP331I Fire Detectors
The KCT731 is a calibration tool to recalibrate the conventionaldetectors after replacement of the field exchangeable optical block.
Specifications
Supply 2 x 9 V batteries
Dimensions (w x h x d) 104 x 195 x 63 mm
Ordering Information
Calibration Tool for KL731/DP331I Fire DetectorsKCT731
Easy to useE
Simple "go/no-go" functionE
Battery operatedE
Addressable Fire Systems
Page : 58
KL700AAnalogue addressable ionisation sensor
The KL700A Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrityand error free operation of the fire system, without compromisingspeed. All sensors are compatible with a standard base that makesthem easily interchangeable and that supports the connection of aremote indicator.
Specifications
Operating voltage 22 - 38 VDC
Current consumption
Quiescent @ 38 VDC 200 A
In alarm less than 11 mA
Alarm indication (Dual LED) White OFF - Red ON
Remote alarm output Available
Environment
Storage temperature -10 °C to +70 °C
Operating temperature -10 °C to +60 °C
Humidity (non condencing) 95%
IP rating IP205
Radioactive source 0.33 ± 0.04 Ci Am 241
Dimensions (h x Ø) 45 mm x 99 mm
Ordering Information
Analogue addressable ionisation sensorKL700A
Remote signalling capabilitiesE
Easy soft addressing (1-125)E
SMD technologyE
Reliable communication protocolE
Full diagnostic self testingE
Full range: Ionisation, Optical and Heat and Duelsensors (optical/heat)
E
Full range of supporting I/O units and accessoriesE
EN54 ApprovedE
Addressable Fire Systems
Page : 59
KL710AAnalogue addressable temperature sensor
The KL700A Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrityand error free operation of the fire system, without compromisingspeed. All sensors are compatible with a standard base that makesthem easily interchangeable and that supports the connection of aremote indicator.
Specifications
Operating voltage 22 - 38 VDC
Current consumption
Quiescent @ 38 VDC 250 A
In alarm less than 11 mA
Alarm indication (Dual LED) White OFF - Red ON
Remote alarm output Available
Environment
Storage temperature -10 °C to +80 °C
Operating temperature -10 °C to +70 °C
Humidity (non condencing) 95%
IP rating IP205
Radioactive source NA
Dimensions (H x Ø) 45 mm x 99 mm
Ordering Information
Analogue addressable temperature sensorKL710A
Remote signalling capabilitiesE
Fixed and Rate-of-Rise heat detectorsE
Easy soft addressing (1-125)E
SMD technologyE
Reliable communication protocolE
Full diagnostic self testingE
Full range: Ionisation, Optical and Heat and Duelsensors (optical/heat)
E
Full range of supporting I/O units and accessoriesE
EN54 ApprovedE
Addressable Fire Systems
Page : 60
KL731AAnalogue addressable optical sensor (with field exchangeable chamber)
The KL700A series detectors use a microprocessor for measurementand communication. An enhanced protocol ensures the overallintegrity and error free operation of the system, without compromisingdetection speed.
All sensors are compatible with a standard base that makes themeasily interchangeable and support the connection of the PA25/3Lremote indicator.
Specifications
Operating voltage 22 - 38 VDC
Current consumption
Quiescent @ 38 VDC 350 A
In alarm Less than 11 mA
Alarm indication (Dual LED) Red
Remote alarm output Available
Environment
Storage temperature -10 °C to +70 °C
Operating temperature -10 °C to +60 °C
Humidity (non condencing) 95%
IP rating IP205
Radioactive source NA
Dimensions (h x Ø) 45 mm x 99 mm
Ordering Information
Analogue addressable optical sensor (with field exchangeable chamber)KL731A Replacement Optical Chamber for KL731/A & DP331I/1561 detectorsKOB700 Universal fire detector base KZ700Universal fire detector base with earth connectionKZ705Analogue fire detector base with sounderKZ705ASAnalogue fire detector base with isolator and sounderKZ705IASAnalogue fire detector base with isolatorKZ705I Low current remote LED indicatorPA25/3L
Remote signalling capabilitiesE
Field exchangeable optical chamberE
Easy soft addressing (1-125)E
SMD technologyE
Reliable communication protocolE
Full diagnostic self testingE
Full range: Ionisation, Optical and Heat and Duelsensors (optical/heat)
E
Full range of supporting I/O units and accessoriesE
EN54 ApprovedE
Black ColourE
Addressable Fire Systems
Page : 61
KL731ABAnalogue addressable optical detector - Black
The KL700A Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrityand error free operation of the fire system, without compromisingspeed. All sensors are compatible with a standard base that makesthem easily interchangeable and that supports the connection of aremote indicator. The KL731B is a black detector specificlly designedfor false ceilings.
Specifications
Operating voltage 22 - 38 VDC
Current consumption
Quiescent @ 38 VDC 350 A
In alarm Less than 11 mA
Alarm indication (Dual LED) Red
Remote alarm output Available
Environment
Storage temperature -10 °C to +70 °C
Operating temperature -10 °C to +60 °C
Humidity (non condencing) 95%
IP rating IP205
Radioactive source NA
Dimensions (h x Ø) 45 mm x 99 mm
Ordering Information
Analogue addressable optical detector - BlackKL731AB Replacement Optical Chamber for KL731/A & DP331I/1561 detectorsKOB700
Remote signalling capabilitiesE
Field exchangeable optical chamberE
Easy soft addressing (1-125)E
SMD technologyE
Reliable communication protocolE
Full diagnostic self testingE
Full range: Ionisation, Optical and Heat and Duelsensors (optical/heat)
E
Full range of supporting I/O units and accessoriesE
EN54 ApprovedE
Black ColourE
Addressable Fire Systems
Page : 62
KL735AAnalogue addressable dual (optical and thermal) sensor
The KL700A Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrityand error free operation of the fire system, without compromisingspeed. All sensors are compatible with a standard base that makesthem easily interchangeable and that supports the connection of aremote indicator.
Specifications
Operating voltage 22 - 38 VDC
Current consumption
Quiescent @ 38 VDC 350 A
In alarm Less than 5 mA
Alarm indication (Dual LED) Red
Remote alarm output Available
Environment
Storage temperature -10 °C to +70 °C
Operating temperature -10 °C to +70 °C
Humidity (non condencing) 95%
IP rating IP42
Radioactive source NA
Dimensions (h x Ø) 51 mm x 99 mm
Ordering Information
Analogue addressable dual (optical and thermal) sensorKL735A
Remote signalling capabilitiesE
Fixed and Rate-of-Rise heat detectorsE
Easy soft addressing (1-125)E
SMD technologyE
Reliable communication protocolE
Full diagnostic self testingE
Full range: Ionisation, Optical and Heat and Duelsensors (optical/heat)
E
Full range of supporting I/O units and accessoriesE
EN54 ApprovedE
Addressable Fire Systems
Page : 63
PG700Fire sensor programmer
The PG700 is a handheld device programmer and tester for theKL700A/Dx1500 series detectors. It is battery operated and allows theinstaller to perform installation tasks (such as device addressing) andmaintenance tasks (such as device calibration) in the field withoutexternal assistance.
Specifications
Supply 2 x 9 V batteries
Dimensions (w x h x d) 104 x 195 x 63 mm
Ordering Information
Fire sensor programmerPG700
Easy to useE
Battery operatedE
4 User selectable programs-Device analogue value-Change Device Address-Sequential device addressing-KL731A Calibration
E
Detector Bases & Accessories
Page : 64
KOB700Replacement Optical Chamber for KL731/A & DP331I/1561 detectors
The KOB700 is an optical replacement chamber for KL731/KL731A andDP331I/DP1561 detectors. It is an inexpensive part that allows easymaintenance of these detectors on site without the need for cleaningsolvents or complicated cleaning procedures. Once replaced, thedetector performs as if it was a new device.
Specifications
Dimensions (Ø x h) 65 x 19 mm
Ordering Information
Replacement Optical Chamber for KL731/A & DP331I/1561 detectorsKOB700
InexpensiveE
Easy replacementE
Reduces maintenance timeE
No additional tools requiredE
KL7ADust Protector Cover for KL700/A and Dx300/1500 detectors
The KL7A is a dust protector cover for the KL700/DI322I andKL731/DP331I conventional, as well as the KL700A/DP1552 andKL731A/DP1561A addressable detectors. It allows for the protection ofthe detector chamber against the ingress of dust from buildingmaterials during construction or renovation of the building.
Ordering Information
Dust Protector Cover for KL700/A and Dx300/1500 detectorsKL7A
Negligible costE
Easy to install and removeE
Avoids unnecessary contamination of the detectorduring building works
E
Detector Bases & Accessories
Page : 65
KZ700Universal fire detector base
The KZ700 is a 4 contact universal detector base. It has the ability tocompensate for uneven mounting surfaces. It is also available in blackfor special applications in false ceilings.
Specifications
Dimensions
Diameter 104 mm
Height 24 mm
Ordering Information
Universal fire detector base KZ700Universal fire detector base (for KL700/A and Dx300/1500) - BlackKZ700B
Polarity sensitiveE
Universal base fits conventional and analoguedetectors
E
Compensates for uneven surfacesE
Remote indicator contact availableE
EN54 approvedE
Variant in black also availableE
Detector Bases & Accessories
Page : 66
KZ700BUniversal fire detector base (for KL700/A and Dx300/1500) - Black
The KZ700B is a black 4 contact universal detecor base for use with theKL700/Dx300 and KL700A/Dx1500 series detectors from GE-Interlogix.It has the ability to compensate for uneven mounting surfaces.
Specifications
Dimensions
Diameter 104 mm
Height 24 mm
Ordering Information
Universal fire detector base (for KL700/A and Dx300/1500) - BlackKZ700B
Polarity sensitiveE
Universal base fits conventional and analoguedetectors
E
Compensates for uneven surfacesE
Remote indicator contact availableE
EN54 approvedE
Variant in black also availableE
Detector Bases & Accessories
Page : 67
KZ705Universal fire detector base with earth connection
The KZ705 is a 5 contact universal detector base for use with theKL700/Dx300 and KL700A/Dx1500 series detectors from GE-Interlogix.In addition to the normal base and remote indication connectors, theKZ705 also has an additional earth terminal connector to allow foreasy terminations of a possible cable screen.
Specifications
Dimensions (Ø x h) 100 x 29 mm
Operating Voltage -
Current Consumption -
Isolation Current -
Isolation Resistance -
Sounder Frequency -
Sound Output
@ 3 mA -
@ 5 mA -
Environmental Characteristics
Operating Temperature -10 to 70 °C
Storage Temperature -10 to 70 °C
Relative Humidity (max) 95 % (non-cond.)
Ordering Information
Universal fire detector base with earth connectionKZ705
Polarity sensitiveE
Universal base fits conventional and analoguedetectors
E
Additional earth terminal availableE
Remote indicator contact availableE
S700Surface mount accessory for KZ700 and KZ705 series bases
The S700 is a base accessory designed for use with the KZ700 seriesdetector bases. It allows for a surface mount conduit and cable toenter the base from the side. The KZ700 series base fits on top of thisaccessory.
Specifications
Dimensions
Diameter 95 mm
Height 30 mm
Ordering Information
Surface mount accessory for KZ700 and KZ705 series basesS700
Surface mount accessory for KZ700 series basesE
Addressable Fire Systems
Page : 68
KZ705IAnalogue fire detector base with isolator
The KZ705I is a detector base with built in isolator for use with theKL700A/Dx1500 series detectors from GE-Interlogix. The isolatorprotects the loop from short circuit conditions. A LED on the side of thebase indicates the status of the isolator.
Specifications
Dimensions (Ø x h) 100 x 29 mm
Operating Voltage 17 - 34 V
Current Consumption 50 A
Isolation Current 6 mA
Isolation Resistance 140 Mohm
Sounder Frequency -
Sound Output
@ 3 mA -
@ 5 mA -
Environmental Characteristics
Operating Temperature -10 °C to +70 °C
Storage Temperature -10 °C to +70 °C
Relative Humidity (max) 95 % (non cond.)
Ordering Information
Analogue fire detector base with isolatorKZ705I
Polarity sensitiveE
Universal base for analogue detectorsE
Additional earth terminal availableE
Remote indicator contact availableE
Built in isolatorE
Addressable Fire Systems
Page : 69
KZ705ASAnalogue fire detector base with sounder
The KZ705AS is a detector base with built in analogue addressablesounder for use with the KL700A/Dx1500 series detectors fromGE-Interlogix. The sounder has its own address on the fire panel loopand works independent of the detector. It is fully controlled from thefire panel.
Specifications
Dimensions (Ø x h) 120 x 58 mm
Operating Voltage 22 - 38 V
Current Consumption 300 A Quiescent
Isolation Current -
Isolation Resistance -
Sounder Frequency 1 kHz (Continuous)
Sound Output
@ 3 mA 85 dBA
@ 5 mA 90 dBA
Environmental Characteristics
Operating Temperature -10 °C to +70 °C
Storage Temperature -10 °C to +70 °C
Relative Humidity (max) 95 % (non cond.)
IP Rating IP21c
Ordering Information
Analogue fire detector base with sounderKZ705AS
Polarity sensitiveE
Universal base for analogue detectorsE
Additional earth terminal availableE
Remote indicator contact availableE
Built in sounderE
Up to 90 dBA sound outputE
Low current consumptionE
Addressable Fire Systems
Page : 70
KZ705IASAnalogue fire detector base with isolator and sounder
The KZ705IAS is a detector base with built in analogue addressablesounder and isolator for use with the KL700A/Dx1500 series detectorsfrom GE-Interlogix. The sounder has its own address on the fire panelloop and works independent of the detector. It is fully controlled fromthe fire panel. The isolator protects the loop from short circuitconditions.
Specifications
Dimensions (Ø x h) 120 x 58 mm
Operating Voltage 22 - 38 V
Current Consumption 350 A Quiescent
Isolation Current 6 mA
Isolation Resistance 140 Mohm
Sounder Frequency 1 kHz (Continuous)
Sound Output
@ 3 mA 85 dBA
@ 5 mA 90 dBA
Environmental Characteristics
Operating Temperature -10 °C to +70 °C
Storage Temperature -10 °C to +70 °C
Relative Humidity (max) 95 % (non cond.)
IP Rating IP21c
Ordering Information
Analogue fire detector base with isolator and sounderKZ705IAS
Polarity sensitiveE
Universal base for analogue detectorsE
Additional earth terminal availableE
Remote indicator contact availableE
Built in sounderE
Up to 90 dBA sound outputE
Low current consumptionE
Built in isolatorE
Conventional Fire Systems
Page : 71
KZ705DConventional fire detector base with diode
The KZ705D is a 5 contact universal detector base for use with theKL700/Dx300 series detectors from GE-Interlogix. In addition to thenormal base and remote indication connectors, the KZ705D also hasan additional earth terminal connector to allow for easy terminationsof a possible cable screen. The built in diode is specifically targeted atsystems using active end-of-line devices.
Specifications
Dimensions (Ø x h) 100 x 29 mm
Operating Voltage -
Current Consumption -
Isolation Current -
Isolation Resistance -
Sounder Frequency -
Sound Output
@ 3 mA -
@ 5 mA -
Environmental Characteristics
Operating Temperature -10 to 70 °C
Storage Temperature -10 to 70 °C
Relative Humidity (max) 95 % (non-cond.)
Ordering Information
Conventional fire detector base with diodeKZ705D
Polarity sensitiveE
Universal base for conventional detectorsE
Additional earth terminal availableE
Remote indicator contact availableE
Built in diode for active end-of-line systemsE
KZ705RConventional 12 VDC fire detector base with relay
The KZ705R is a 5 contact detector base for use with the KL731/DP331Idetectors from GE-Interlogix. In addition to the normal base andremote indication connectors, the KZ705R also has an additional earthterminal connector to allow for easy terminations of a possible cablescreen. A built in 12 V relay makes it ideal for use on low voltageintrusion systems.
Specifications
Dimensions (Ø x h) 100 x 29 mm
Operating Voltage 12 V ± 10%
Current Consumption 12 A
Isolation Current -
Isolation Resistance -
Sounder Frequency -
Sound Output
@ 3 mA -
@ 5 mA -
Environmental Characteristics
Operating Temperature -10 °C to +70 °C
Storage Temperature -10 °C to +70 °C
Relative Humdity 95 % (non cond.)
Ordering Information
Conventional 12 VDC fire detector base with relayKZ705R
Polarity sensitiveE
12 V relay for 4 wire systemsE
Additional earth terminal availableE
Remote indicator contact availableE
Annunciators
Page : 72
PA25/3LLow current remote LED indicator
The PA25 remote indicators have been designed for direct connectionto fire detectors (conventional and analogue), enabling luminousindication outside the area where the detector is installed.
Specifications
Electrical Specifications
Supply Voltage (Analogue) 5 to 10 VDC
Current Consumption 2 to 79 mA
Supply Voltage (Conventional) 2 to 5 VDC
Current Consumption 6.5 to 61.5 mA
Mechanical Specifications
Size (w x h x d) 80 x 80 x 42 mm
Weight 10 g
Box material A.B.S.
Colour White
Environmental Specifications
Protection level IP20
Working temperature -10 to +60 °C
Storage temperature -10 to +70 °C
Ordering Information
Low current remote LED indicatorPA25/3L
Direct two-wire connection to detectorE
Large angle of visibility - lit up on four sidesE
Low current consumptionE
Flashing optionE
2 to 10 VDC power supplyE
High luminosityE
Compatible with third party productsE
IP20 protection levelE
Modern and elegant designE
ABS plastic casing with ruby red polycarbonatespy-hole
E
Shock resistantE
Addressable Fire Systems
Page : 73
KAL410Conventional Zone Monitor Unit - 1 Zone
Allows the connection of one conventional zone to the analogue firesystem loop. This zone is constantly monitored. Up to 20 conventionaldevices may be connected to this zone.
Specifications
Supply voltage 22-38 VDC
Current consumption
Quiescent @ 24 V 90 A
Quiescent @ 35 V 105 A
Alarm < 3 mA
Aux. supply (24 VDC)quiescent
200 A + equip
Aux. supply (24 VDC) alarm < 85 mA
End-of-line resistor 4.7 kohm
Relay contact rating NA
Environmental
Storage temperature -10 °C to +50°C
Operating temperature -10 °C to +70°C
Relative humidity 95 % (non condensing)
Dimensions (L x W x H) 117 x 80 x 44 mm
Ordering Information
Conventional Zone Monitor Unit - 1 ZoneKAL410
Easy numeric addressingE
Continuous supervision of the conventional zonesE
Surface mountE
Local alarm indicationE
Externally or loop poweredE
Aesthetically pleasingE
Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control
E
Addressable Fire Systems
Page : 74
KAL414CConventional Zone Monitor Unit - 4 Zones
Allows the connection of four conventional zones to the analogue firesystem loop. These zones are constantly monitored. Up to 20conventional devices may be connected to any zone.
Specifications
Supply voltage 22-38 VDC
Current consumption
Quiescent @ 24 V 110 A
Quiescent @ 35 V 135 A
Alarm < 5 mA
Aux. Supply (24V DC)Quiescent
200 A + equip
Aux. Supply (24V DC) Alarm < 360 mA
End-of-line resistor 4.7 kOhm
Relay contact rating NA
Environmental
Storage temperature -10 to +50°C
Operating temperature -10 to +70°C
Relative humidity(non-condensing)
0-95 %
Dimensions (l x w x h) 163 x 107 x 36 mm
Ordering Information
Conventional Zone Monitor Unit - 4 ZonesKAL414C
Easy numeric addressingE
Continuous supervision of the conventional zonesE
Surface mountE
Local alarm indicationE
Externally poweredE
Aesthetically pleasingE
Part of a family of I/O modules consisting of:E
- Conventional Zone MonitorsE
- Digital Input ModulesE
- Extinguishing Control ModulesE
- Isolator ModulesE
- Manual Call PointsE
- Output UnitsE
- Retention UnitsE
- Supervised Output Units for sounder controlE
Addressable Fire Systems
Page : 75
KAL426CExtinguishing Control Module
The 400 Series modules consists of a complete range of interfacesdeveloped for input/output control in the KSA700/FP1500 analogue firesystems from GE Interlogix. The KAL426 allows for the connection andcontrol of one extinguishing area to the addressable fire panel loop.
Specifications
Supply voltage 22-38 VDC
Current consumption
Quiescent @ 24 V 110 A
Quiescent @ 35 V 210 A
Alarm < 10 mA
Aux. supply (24 VDC)quiescent
120 mA
Aux. supply (24 VDC) alarm < 1 A
End-of-line resistor 4.7 kOhm
Relay contact rating 2½ A
Environmental
Storage temperature -10 °C to +50°C
Operating temperature -10 °C to +70°C
Relative humidity 95 % (non condensing)
Dimensions (L x W x H) 163 x 107 x 36 mm
Ordering Information
Extinguishing Control ModuleKAL426C
Aesthetically pleasingE
Easy numeric addressingE
Externally poweredE
Supervised I/OE
Surface mountE
Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control
E
Addressable Fire Systems
Page : 76
KAL430Relay Module - 1 Relay
Provides for one potential free relay output for the fire system loop.Each relay allows for COMMON, NORMALLY OPEN and NORMALLYCLOSED contacts. The output may be used to activate ventilationcontrols, warning signs, activation of other alarm devices etc. duringfire situations.
Specifications
Supply voltage 22-38 VDC
Current consumption
Quiescent @ 24 V 70 A
Quiescent @ 35 V 100 A
Alarm < 3.5 mA
Aux. 24 VDC quiescent 22 mA
Aux. 24 VDC alarm < 50 mA
End-of-line resistor NA
Relay contact rating 2½A @ 250 VAC
Environmental
Storage temperature -10 °C to +50°C
Operating temperature -10 °C to +70°C
Relative humidity 95 % (non condensing)
Dimensions (L x W x H) 117 x 80 x 44 mm
Ordering Information
Relay Module - 1 RelayKAL430
Easy numeric addressingE
Externally or loop poweredE
Normally open / normally closed operation for I/OE
Surface mountE
Aesthetically pleasingE
Local status indicationE
Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control
E
Addressable Fire Systems
Page : 77
KAL434CAddressable Relay Module - 4 Relays
Provides for four potential free relay outputs for the fire system loop.Each relay allows for COMMON, NORMALLY OPEN and NORMALLYCLOSED contacts. The outputs may be used to activate ventilationcontrols, warning signs, activation of other alarm devices etc. duringfire situations.
Specifications
Supply voltage 22-38 VDC
Current consumption
Quiescent @ 24 V 110 A
Quiescent @ 35 V 135 A
Alarm 10 mA
Aux. 24VDC Quiescent 100 A
Aux. 24VDC Alarm 10 mA
End-of-line resistor NA
Relay contact rating 2½A @ 250 VAC
Environmental
Storage temperature -10 to +50°C
Operating temperature -10 to +70°C
Relative humidity (non-cond.) 0-95 %
Dimensions (l x w x h) 163 x 107 x 36 mm
Ordering Information
Addressable Relay Module - 4 RelaysKAL434C
Easy numeric addressingE
Externally poweredE
Normally open / normally closed operation for I/OE
Surface mountE
Aesthetically pleasingE
Local status indicationE
Part of a family of I/O modules consiting of:E
- Conventional Zone MonitorsE
- Digital Input ModulesE
- Extinguishing Control ModulesE
- Isolator ModulesE
- Manual Call PointsE
- Output UnitsE
- Retention UnitsE
- Supervised Output Units for sounder controlE
Addressable Fire Systems
Page : 78
KAL440Supervised Relay Module
Allows for the supervision of a single, 24 Volt powered output contacton the fire system loop. This unit may be used to control for e.g.sounders in case of fire conditions, but may also be used to switch anyoutput considered crucial enough to have the cable integrity betweenthe unit and the switch point monitored.
Specifications
Supply voltage 22-38 VDC
Current consumption
Quiescent @ 24 V 110 A
Quiescent @ 35 V 135 A
Alarm < 3.6 mA
Aux. 24 VDC quiescent 23 mA
Aux. 24 VDC alarm 23 mA + equip
End-of-line resistor 4.7 kohm
Relay contact rating 1¼ A @ 250 VAC
Environmental
Storage temperature -10 °C to +50°C
Operating temperature -10 °C to +70°C
Relative humidity 95 % (non condensing)
Dimensions (L x W x H) 117 x 80 x 44 mm
Ordering Information
Supervised Relay ModuleKAL440
Easy numeric addressingE
Externally poweredE
Supervised 24 VDC Output E
Surface mountE
Aesthetically pleasingE
Local status indicationE
Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control
E
Addressable Fire Systems
Page : 79
KAL450Addressable Manual Call Point
The 400 Series modules consists of a complete range of interfacesdeveloped for input/output control in the KSA700/FP1500 analogue firesystems from GE Interlogix. The KAL450 is an addressable manual callpoint for manual fire activation.
Specifications
Supply voltage 22-38 VDC
Current consumption
Quiescent @ 24 V 90 A
Quiescent @ 35 V 120 A
Alarm < 3.5 mA
Aux. supply (24 VDC)quiescent
NA
Aux. supply (24 VDC) alarm NA
End-of-line resistor NA
Relay contact rating NA
Environmental
Storage temperature -10 °C to +70°C
Operating temperature -10 °C to +50°C
Relative humidity 95 % (non condensing)
Ingress Protection IP20
Dimensions (L x W x H) 87 x 87 x 20 mm
Weight 98 g
Ordering Information
Addressable Manual Call PointKAL450EN54 universal glass for manual call pointDM715Terminal tray for MCPDM780GS cardDM781Hinged transparent MCP protection coverDM782BZB black bezelDM783Test keyDM784Spacer box, redDM785Surface mounting box with connectors, redDM787Surface mount box without connectors, redDM788Flush mount cradle with connectorsDM790Flush mount cradle, connectors & forkgripsDM795Breakable seal for MCPDM798Terminal tray ETT/3 with bezel 3DM799Resettable element for MCP DM700/KAL450DM800
Easy numeric addressingE
Loop poweredE
Local test facilityE
Surface or flush mountE
Aesthetically pleasingE
Local status indicationE
Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control
E
Wide range of accessoriesE
Manual Call Points
Page : 80
DM715EN54 universal glass for manual call point
The DM715 is a universal EN54 approved break glass for the DM700series and KAL450 manual call points.
Ordering Information
EN54 universal glass for manual call pointDM715Resettable element for MCP DM700/KAL450DM800
Plastic coated to prevent operator injuryE
No glass fragments on breakingE
No hammer requiredE
Approved EN54 part 11E
DM782Hinged transparent MCP protection cover
The DM782 anti-tamper plastic cover is a protection cover for theDM700 and KAL450 manual call points. It prevents accidentalactivation of the alarm by enforcing a two step action i.e. lifting thecover, then activating the alarm.
Ordering Information
Hinged transparent MCP protection coverDM782Breakable seal for MCPDM798
UnobtrusiveE
TransparentE
Protects from accidental alarm activationE
Manual Call Points
Page : 81
DM787Surface mounting box with connectors, red
The DM787 is surface mounting back-box for DM700 series andKAL450 series manual call points. The DM787 is red and has 3 wiringterminals
Specifications
Material Self-extinguishing Noryl SE100
Colour Red - RAL N°3020
Operating temperature -40° to +85°C
Relative humidity max. 90% RV
Ordering Information
Surface mounting box with connectors, redDM787Surface mounting box with connectors, yellowDM787YSurface mounting box with connectors, blueDM787BSurface mounting box with connectors, greenDM787GSurface mount box without connectors, redDM788
Easy to installE
For flush mounting of manual call pointsE
Three terminalsE
Addressable Fire Systems
Page : 82
KAL460Digital Input Module
Provides a remote input to the fire system loop. The input is constantlymonitored and its status communicated to the fire control panel. Theinput may be activated by closing or opening a potential free contact,depending on the module configuration.
This module may be used to monitor any contact by showing its statusthrough the fire control panel e.g. the monitoring of pressureequipment and closure fire break doors.
Specifications
Supply voltage 22-38 VDC
Current consumption
Quiescent @ 24 V 110 A
Quiescent @ 35 V 135 A
Alarm < 10 mA
Aux. 24 VDC quiescent 200 A
Aux. 24 VDC alarm < 50 mA
End-of-line resistor NA
Relay contact rating NA
Environmental
Storage temperature -10 °C to +50°C
Operating temperature -10 °C to +70°C
Relative humidity 95 % (non condensing)
Dimensions (L x W x H) 117 x 80 x 44 mm
Ordering Information
Digital Input ModuleKAL460
Easy numeric addressingE
Externally or loop poweredE
Normally open / normally closed operation for I/OE
Surface mountE
Aesthetically pleasingE
Local status indicationE
Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control
E
Addressable Fire Systems
Page : 83
KAL470Isolator Module
The 400 series modules consist of a complete range of interfacesdeveloped for input/output control in the KSA700/FP1500 analogue firesystems from GE Interlogix. The KAL470 is an isolator module in thisseries that isolates the faulty zone on a fire panel loop during shortcircuit conditions. The KAL470 does not use an address on the loop.
Specifications
Supply voltage 22-38 VDC
Current consumption
Quiescent @ 24 V 110 A
Quiescent @ 35 V 135 A
Alarm 10 mA
Aux. supply (24 VDC)quiescent
NA
Aux. supply (24 VDC) alarm NA
End-of-line resistor NA
Relay contact rating NA
Environmental
Storage temperature -10 °C to +50°C
Operating temperature -10 °C to +50°C
Relative humidity 95 % (non condensing)
Dimensions (L x W x H) 75 x 45 x 28 mm
Ordering Information
Isolator ModuleKAL470
Requires no device addressE
Automatic resetE
Local status indicationE
Surface mountE
Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control
E
Addressable Fire Systems
Page : 84
KAL490Retention Module - 1 Input / 1 Output
Provides a remote input and a potential free voltage relay output tothe fire system loop. The input signal is constantly monitored and itsstatus displayed on the control panel, whilst the output is fail-to-safe.Auxiliary supply monitoring is also included.
The module is used to for e.g. control and monitor doors such as firebreak doors. The relay provides the door activation and the inputmonitors the door status.
Specifications
Supply voltage 22-38 VDC
Current consumption
Quiescent @ 24 V 110 A
Quiescent @ 35 V 135 A
Alarm 10 mA
Aux. 24 VDC quiescent 200 A
Aux. 24 VDC alarm < 50 mA
End-of-line resistor NA
Relay contact rating 1A @ 30 VAC/VDC
Environmental
Storage temperature -10 °C to +50°C
Operating temperature -10 °C to +70°C
Relative humidity 95 % (non condensing)
Dimensions (L x W x H) 117 x 80 x 44 mm
Ordering Information
Retention Module - 1 Input / 1 OutputKAL490
Easy numeric addressingE
Externally or loop poweredE
Normally open / normally closed operation for I/OE
Surface mountE
Aesthetically pleasingE
Local status indicationE
Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control
E
Addressable Fire Systems
Page : 85
SK07AAddressable loop powered siren
The SK07A loop powered siren is designed for connection to andcontrol by the KSA700/FP1500 analogue fire detection systems fromGE-Interlogix. Communication is done digitally between the fire paneland the sounder.
Specifications
Electrical
Supply Voltage 22 - 38 VDC
Quiescent current 300 A
Alarm current 6 mA
Maximum sound level 87 dBA
Mechanical
Dimensions 63 mm (h) x 93 mm Ø
Maximum cable size 2.5 mm²
Fastening Screws 2 x 30 mm
Environmental
Working temperature -20 °C to +50 °C
Storage temperature -20 °C to +70 °C
Relative humidity (maximum) 95 %
Protection Index IP445
Ordering Information
Addressable loop powered sirenSK07A
EN54 part 3 compliantE
Up to 87 dBA sound outputE
Low current consumptionE
Low profileE
IP445 protection levelE
Easy installationE
Polarity sensitiveE
Rear and side cable entry possibleE
Low and easy maintenanceE
Annunciators
Page : 86
KR24BIlluminated warning sign (No text) 24VDC
The KR24 is specifically designed as an evacuation warning sign forgas extinguising areas. The KR24B has no text on the backlit display,and text may therefor be added as required for the application. Unitssupplied with text in various languages are also available.
Specifications
Electrical Specifications
Supply Voltage 18 to 27 VDC
Activation Voltage 18 to 27 VDC
Current Consumption 600 mA
Switching Polarity NA
Indicators 24 V 3 W
Environmental Specifications
Working Temperature -10 to 75 °C
Physical Specifications
Number of zones NA
Buzzer output 80 dB
Housing Colour Grey
Display Colour Red
Weight 700 g
Size (w x h x d) 255 x 110 x 50 mm
IP Rating IP50
Ordering Information
Illuminated warning sign (No text) 24VDC KR24B
Low current consumptionE
Large angle of viewE
Optical and acoustic indications selectableE
Modern and elegant designE
Annunciators
Page : 87
KR24-INGIlluminated extinguishing waring sign (English version) 24VDC
The KR24 is a backlit "No Entry / Extinguishing Release" warning sign tobe used with gas extinguishing areas. Warning text is available invarious languages.
Specifications
Electrical Specifications
Supply Voltage 18 to 27 VDC
Activation Voltage 18 to 27 VDC
Current Consumption 600 mA
Switching Polarity NA
Indicators 24 V 3 W
Environmental Specifications
Working Temperature -10 to 75 °C
Physical Specifications
Number of zones NA
Buzzer output 80 dB
Housing Colour Grey
Display Colour Red
Weight 700 g
Size (w x h x d) 255 x 110 x 50 mm
IP Rating IP50
Ordering Information
Illuminated extinguishing waring sign (English version) 24VDC KR24-ING
Low ConsumptionE
Large angle of visionE
Optical and acoustic indication selectable E
Modern and elegant designE
Annunciators
Page : 88
SK07Low consumption multi-tone alarm siren
The SK07 multi-tone siren is designed to sound an acoustic alarminside buildings. This small, low profile siren combines a high soundoutput with low power consumption. It complies with the requirementsof EN 54 part 3.
Specifications
Electrical
Supply Voltage 22 - 26 VDC
Alarm current 3 mA at 85 dBA or less than 20 mA at 95 dBA
Maximum sound level 95 dBA
Working temperature -20 °C to 50 °C
Storage temperature -20 °C to 70 °C
Maximum relative humidity 95 % (non condencing)
Mechanical
Dimensions 63 mm (h) x 93 mm Ø
Protection Index IP445
Fastening screws 2 x 30 mm
Maximum cable section 2.5 mm²
Recommended cable size Single core 1.5 mm²
Ordering Information
Low consumption multi-tone alarm sirenSK07
Low profileE
Easy installationE
Back and side cable entryE
Polarity sensitiveE
Connection base includedE
Input and output terminals includedE
Acoustic power output selectionE
Up to 95 dBA sound outputE
Eight different alarm tonesE
Automatic tone changeE
Low current consumptionE
Low maintenanceE
IP445 protection levelE
EN54 part 3 compliantE
Addressable Fire Systems
Page : 89
PCC-ConfigKSA701/FP1500 Configuration software kit
PCC-Config allows easy, menu driven, programming of all the featuresand settings of the panel. Common texts can be easily copied tosensors and zones. Programming becomes simple as all settings aredisplayed for the programmers convenience.
Specifications
Hardware requirements
Communication RS232, modem and/or TCP/IP
Display VGA or higher resolution
Hard disk 2 Gb with 650 Mb free space
Keyboard Required
Pointing device Required
Printer System printer required for printing
Processor 133 MHz or higher Pentium-compatible CPU
RAM 64 Mb or more
Removable media 1.44 Mb stiffy and CD-ROM or DVD drive
Software requirements
Operating system Win '98, Win 2000, Win XP
Ordering Information
KSA701/FP1500 Configuration software kitPCC-ConfigKSA702/5 Configuration software kitKSP700
Windows based E
Complete external configuration of the installationE
Configuration possibilities for single and networked firesystems
E
Local or remote operation via modem or TCP/IPE
Standard RS232 communicationE
Addressable Fire Systems
Page : 90
PCG-Graphic102Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops)
The PCG-Config series consists of 3 software applications. Theindividual software formats allows the graphic package to grow withthe installation. PCG-Config102 operates with a single panel and allowsfor the configuration of all devices up to a maximum of two loops.
Specifications
Hardware requirements
Communication RS232, modem and/or TCP/IP
Display SVGA or higher resolution
Hard disk 2 Gb with 650 Mb free space
Keyboard Required
Pointing device Required
Printer System printer required for printing
Processor 1 GHz or higher Pentium III-compatible CPU
RAM 256 Mb or more
Removable media 1.44 Mb stiffy and CD-ROM or DVD drive
Software requirements
Operating system Windows '98 or Windows 2000
Ordering Information
Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops)PCG-Graphic102
Bi-directional communication with single panels andnetworked fire systems
E
Local or remote connection via modem or TCP/IPE
Large selection of user configurable iconsE
Visualises device alarms and status of in- and outputsE
Event texts retrieval from the panelE
Configurator and operator contol levelsE
Navigation buttons allowedE
Event logs with reporting facilitiesE
Basic drawing package includedE
Imports bmp & drw format graphicsE
Addressable Fire Systems
Page : 91
PCG-Graphic105Graphic Software for KSA700/FP1500 Fire Systems (1 panel-5 loops)
The PCG-Config series consists of 3 software applications. Theindividual software formats allows the graphic package to grow withthe installation. PCG-Config105 supports a single panel up to 5 loops.
Specifications
Hardware requirements
Communication RS232, modem and/or TCP/IP
Display SVGA or higher resolution
Hard disk 2 Gb with 650 Mb free space
Keyboard Required
Pointing device Required
Printer System printer required for printing
Processor 1 GHz or higher Pentium III-compatible CPU
RAM 256 Mb or more
Removable media 1.44 Mb stiffy and CD-ROM or DVD drive
Software requirements
Operating system Windows '98 or Windows 2000
Ordering Information
Graphic Software for KSA700/FP1500 Fire Systems (1 panel-5 loops)PCG-Graphic105Bi-directional communication with single panels andnetworked fire systems
E
Local or remote connection via modem or TCP/IPE
Large selection of user configurable iconsE
Visualises device alarms and status of in- and outputsE
Event texts retrieval from the panelE
Configurator and operator contol levelsE
Navigation buttons allowedE
Event logs with reporting facilitiesE
Basic drawing package includedE
Imports bmp & drw format graphicsE
Addressable Fire Systems
Page : 92
PCG-GraphicNWGraphic Software for KSA700/FP1500 Fire Systems (multi-panel)
The PCG-Config series consists of 3 software applications. Theindividual software formats allows the graphic package to grow withthe installation. PCG-ConfigNW allows for monitoring on networkedsystems with multiple panels.
Specifications
Hardware requirements
Communication RS232, modem and/or TCP/IP
Display SVGA or higher resolution
Hard disk 2 Gb with 650 Mb free space
Keyboard Required
Pointing device Required
Printer System printer required for printing
Processor 1 GHz or higher Pentium III-compatible CPU
RAM 256 Mb or more
Removable media 1.44 Mb stiffy and CD-ROM or DVD drive
Software requirements
Operating system Windows '98 or Windows 2000
Ordering Information
Graphic Software for KSA700/FP1500 Fire Systems (multi-panel)PCG-GraphicNW
Bi-directional communication with single panels andnetworked fire systems
E
Local or remote connection via modem or TCP/IPE
Large selection of user configurable iconsE
Visualises device alarms and status of in- and outputsE
Event texts retrieval from the panelE
Configurator and operator contol levelsE
Navigation buttons allowedE
Event logs with reporting facilitiesE
Basic drawing package includedE
Imports bmp & drw format graphicsE
Addressable Fire Systems
Page : 93
KSP700KSA702/5 Configuration software kit
The KSP700 provides for a interface for the Kilsen KSA702 and KSA705analogue addressable fire panels for the up/downloading of the firepanel configuration software from a PC. It is supplied as a kit, includingthe configuration cable together with PCC-Config, the softwareconfiguration program for these panels.
Specifications
Hardware requirements
Communication RS232, modem and/or TCP/IP
Display VGA or higher resolution
Hard disk 2 Gb with 650 Mb free space
Keyboard Required
Pointing device Required
Printer System printer required for printing
Processor 133 MHz or higher Pentium-compatible CPU
RAM 64 Mb or more
Removable media 1.44 Mb stiffy and CD-ROM or DVD drive
Software requirements
Operating system Win '98, Win 2000, Win XP
Ordering Information
KSA702/5 Configuration software kitKSP700
Windows based E
Complete external configuration of the installationE
Configuration possibilities for single and networked firesystems
E
Local or remote operation via modem or TCP/IPE
Communications interface includedE
Addressable Fire Systems
Page : 94
KSP701PC Configuration RS232 Cable for KSA701/FP1500 fire panels
The KSP701 is a RS232 cable for connecting the KSA701 Series orFP1500 Series fire panels to an industry standard RS232 port on anyPC. It is normaly included with all software applications for thesepanels, but may also be ordered seperately when required.
Ordering Information
PC Configuration RS232 Cable for KSA701/FP1500 fire panelsKSP701
Complete RS232 cable with connectorsE
Addressable Fire Systems
Page : 95
PCC2000Programming and configuration software
PCC2000 allows easy, menu driven, programming of all the panel'sfeatures and settings. Common texts can be easily copied whilesensors, zones and areas increment or follow automatically. Booleanlogic programming becomes simple as inputs and outputs arecontinuously displayed for the programmer's convenience.
Specifications
Processor 486 66 MHz
RAM 12 Mb
Display adapter VGA
Hard disk space 20 MB
Pointing device MS Mouse
Graphical environment Windows 98, 2000, XP
Communications ports 1 x RS232
1 x Parallel
Ordering Information
Programming and configuration softwarePCC2000
Provide communication with single fire panels andnetworked fire systems, both locally or remote viamodem
E
Windows 98, 2000 and XP compatibleE
For use with 2000/1200 series panelsE
Menu drivenE
Full or partial up- and downloadE
Addressable Fire Systems
Page : 96
PCG-NGraphics package network application with copy protection key
2 Packages allow the graphic package to grow with the installation.The basic version PCG-S operates with a single panel, while the PCG-Nsupports a network. Upgrades do not require rework on the existingdatabase, drawings, etc.
Specifications
Processor Pentium II 266 MHz (or better)
RAM 64 Mb (or more)
Display adapter SVGA or better
Hard disk space 200 MB
Pointing device MS Mouse, Bus or P/S2
Graphical environment Windows NT
Communication ports 1 x RS-232 - Depending on drivers
1 x Parallel - Printer port (for key)
Ordering Information
Graphics package network application with copy protection keyPCG-N
Provide bi-directional communication with single firepanels and networked fire systems, both locally andremote via modem
E
Windows 2000 and NT compatibleE
For use with FP2000, FP1200, FP1100 and FP700E
Constructed around Sybase SQL AnywhereE
Large selection of iconsE
Visualises inputs & outputsE
Information page per pointE
Get texts from panelE
Several operator levels and passwordsE
Operator configurableE
Multiple navigation buttonsE
Event logsE
Basic drawing package includedE
Imports .bmp & .wmf drawings from virtually anypackage
E
Hardware key protectedE
Addressable Fire Systems
Page : 97
PCG-SGraphics package with copy protection key
2 Packages allow the graphic package to grow with the installation.The basic version PCG-S operates with a single panel, while the PCG-Nsupports a network. Upgrades do not require rework on the existingdatabase, drawings, etc.
Specifications
Item Recommended
Processor Pentium II 266 MHz (or better)
RAM 64 Mb (or more)
Display adapter SVGA or better
Hard disk space 200 MB
Pointing device MS Mouse, Bus or P/S2
Graphical environment Windows NT
Communication ports 1 x RS-232 - Depending on drivers
1 x Parallel - Printer port (for key)
Ordering Information
Graphics package with copy protection keyPCG-S
Provide bi-directional communication with single firepanels and networked fire systems, both locally andremote via modem
E
Windows 2000 and NT compatibleE
For use with FP2000, FP1200, FP1100 and FP700E
Constructed around Sybase SQL AnywhereE
Large selection of iconsE
Visualises inputs & outputsE
Information page per pointE
Get texts from panelE
Several operator levels and passwordsE
Operator configurableE
Multiple navigation buttonsE
Event logsE
Basic drawing package includedE
Imports .bmp & .wmf drawings from virtually anypackage
E
Hardware key protectedE
Addressable Fire Systems
Page : 98
PCM2000Maintenance and support software with copy protection key
PCM2000 allows local and remote maintenance facilities for 1200/2000series fire panels. Amongst others, it allows for full panel emulation,data retrieval and central alarm monitoring.
Specifications
Processor Pentium 133Mhz (or better)
RAM 32 Mb (or more)
Display Adapter VGA
Hard Disk Space 20 MB
Pointing Device Bus or P/S2 Mouse
Graphical Environment Windows 98, NT or 2000
Communications ports Depending on Drivers Printer port (for key)
1 Parallel
Ordering Information
Maintenance and support software with copy protection keyPCM2000
Provide communication with single fire panels andnetworked fire systems, both locally or remote viamodem
E
Windows 95, 98 and NT compatibleE
For use with FP2000, FP1200E
Full panel emulationE
Data retrievalE
Central stationE
History logE
Address bookE
Dynamic Link Library (DLL) for third party integrationE
Special Temperature Detectors
Page : 99
ST801High Temperature Thermal Probe with 2 wire connection
The ST801 thermal probe high temperature heat detector is designedto protect from hazards where high temperatures are produced at aspecific point. The sensitive element (bulb) can be set at a distance ofup to 1 meter from the connection box. The ST801 may be connectedvia 2 wires directly to a conventional fire panel zone.
Specifications
Suppy Voltage 24 VDC
Current Consumption
Quiescent Ø
Alarm 100 mA
Alarm Monitoring Two wires to conventional zone
Capilliary pipe length 1 m
Probe Dimentions (l x Ø) 150 x 3 mm
Dimensions 140 x 100 x 70 mm
Colour Grey RAL7032
Working Temperature 50 °C to 300 °C
Weight 0.8 kg
Ordering Information
High Temperature Thermal Probe with 2 wire connectionST801
Completely metalE
Adjustable from 50 to 300 °CE
Back and side cable inputE
Sensitive probe with 1 m of stainless steel capillarypiping
E
Resistant to heat, grease and humidityE
Easy installationE
Easy connectionE
Easy maintenanceE
Ideal for commercial areasE
Special Temperature Detectors
Page : 100
ST802High Temperature Thermal Probe with relay output
The ST802 thermal probe high temperature heat detector is designedto protect from hazards where high temperatures are produced at aspecific point. The sensitive element (bulb) can be set at a distance ofup to 1 meter from the connection box. The ST802 provides a protentialfree relay output for alarm indication with COM, NC and NO contacts.
Specifications
Suppy Voltage 24 VDC
Current Consumption
Quiescent Ø
Alarm 100 mA
Alarm Monitoring 5A potential free relay
Capilliary pipe length 1 m
Probe Dimentions (l x Ø) 150 x 3 mm
Dimensions 140 x 100 x 70 mm
Colour Grey RAL7032
Working Temperature 50 °C to 300 °C
Weight 0.6 kg
Ordering Information
High Temperature Thermal Probe with relay outputST802
Completely metalE
Adjustable from 50 to 300 °CE
Back and side cable inputE
Sensitive probe with 1 m of stainless steel capillarypiping
E
Resistant to heat, grease and humidityE
Easy installationE
Easy connectionE
Easy maintenanceE
Potenial free alarm relay outputE
Door Magnets
Page : 101
CR255Electronic delay control for double-leaf fire doors
The CR255 is an electronic delay control unit for use with double-leaffire doors. It allows for the release of the one leaf of the fire door to beslightly delayed to allow for the two leafs to close properly and in thecorrect sequence.
Ordering Information
Electronic delay control for double-leaf fire doorsCR255
Easy to installE
May be installed inside the door release magnethousing
E
24 VDC operationE
Content
NKB602 Conventional fire alarm panel with 2 zones Page : 3
NKB604 Conventional fire alarm panel with 4 zones Page : 4
NKB606 Conventional fire alarm panel with 6 zones Page : 5
NK702 Conventional fire panel with 2 fire alarm zones Page : 6
NK704 Conventional fire panel with 4 fire alarm zones Page : 7
NK708 Conventional fire panel with 8 fire alarm zones Page : 8
NK712 Conventional fire panel with 12 fire alarm zones Page : 9
NK716 Conventional fire panel with 16 fire alarm zones Page : 10
NK703 Conventional extinguishing control panel with 3 zones Page : 11
NK706 Conventional extinguishing control panel with 6 zones Page : 12
RB404 Relay module, 4 potential free relays for NK700/Fx400 fire panels Page : 13
SB404 Relay module, 4 supervised relays for NK700/Fx400 fire panels Page : 14
EOL-ACT Active end-of-line device for use with FP400/KL700 fire panels Page : 15
KLBlack-S Black front panel cover (small footprint) Page : 16
KLBlack-B Black front panel cover (large footprint) Page : 16
KSA701-1 Analogue addressable fire detection panel - 1 loop Page : 17
KSA701-2 Analogue addressable fire detection panel - 2 loops Page : 18
NC785 RS485 expansion kit for KSA701/FP1500 fire panels Page : 19
KSA701R KSA701 Series LCD Repeater (mains powered) Page : 20
KSA701R-24 KSA701 Series LCD Repeater (24VDC powered) Page : 21
KSA705 Analogue addressable fire panel (expandable to 5 loops) Page : 22
KSA705P Analogue addressable fire panel with printer (expandable to 5 loops) Page : 23
KAL701 Loop driver module for KSA702/705 control panels Page : 24
KAL732 RS232 communications module for KSA702/5 control panels Page : 24
KAL785 RS485 communications module for KSA702/5 control panels Page : 25
KAL791 Protocol Converter RS232/485 - Kilsen / Johnsson Control Page : 25
KSA1204 Analogue fire panel, 2 loops upgradable to 4, 64 display zones Page : 26
KSA1208 Addressable fire panel, 2-8 loops, 64-255 display zones upgradable Page : 27
KSA1264R Repeater / emulator with 64 zone indications Page : 28
KSA12255R Global zone repeater, 64 zones expandable up to 255 Page : 29
LC1502 2-loop extension board for 1200/2000 series fire panels Page : 30
LON2000 LON700 driver for FP1200 / FP2000 Page : 30
LON2000R LON driver for FP1200/2000 - closed loop systems Page : 31
NC2011 ARCNET RS485 network card with single RS485 interface Page : 31
NC2051 ARCNET network card with single optical interface board Page : 32
NE2011 RS485 network extension board Page : 32
NE2051 Fibre optic network extension board Page : 33
PR2000 Internal printer Page : 33
RB2016 Relay extension board for 1200/2000 series fire panels Page : 34
ZE2064 64-zone LED extension fire and fault LED Page : 34
FRL700 LCD repeater Page : 35
NA704 LON700 network amplifier (4 way) Page : 36
NC700 LON700 interface board Page : 36
NC771 LON700 closed loop communication board (no driver) Page : 37
NE771 LON700 driver for the NC771 and NA704 Page : 37
OCB724 LON700 output board with 24 open collector outputs Page : 38
PS700 Plug-in power supply 3.5 A Page : 38
RB708 LON700 output board with 8 relays Page : 39
SIB716 Supervised input board 16 way LON700 Page : 39
SOB708 LON700 output board with 8 supervised outputs Page : 40
ZI708 8 zone input extension board Page : 40
KM260/1R3-03 CO detection control panel - 1 Zone (English Version) Page : 41
KM260/3R3-03 CO detection control panel - 3 Zones (English Version) Page : 42
KM260EXT3-03 CO detection expansion module (English Version) Page : 43
KM260C Blanking plate for KM260 panels Page : 44
KM170 CO detector with base and mounting supplement Page : 45
KZ400 Detector base for KL400/KM170 series devices Page : 46
S300 Surface mount supplement for KL300/KM170 detectors Page : 46
ASD20C Aspiration Smoke Detector Page : 47
ASD20F Filter housing for ASD20 Page : 48
ASD20FIL Filter only for ASD20 Page : 48
KV210 Rate-of-Rise Heat Detector Page : 49
KV210P Rate-of-Rise Heat Detectors with remote indicator output Page : 50
KL500 Low Profile Ionisation Smoke Detector Page : 51
KZ500 Fire detector base for KL500 detectors Page : 52
KL700 Ionisation detector, conventional Page : 53
KL710 Temperature detector (fixed and rate-of-rise), conventional Page : 54
KL731 Optical detector, conventional (with field exchangeable optical block) Page : 55
KL731B Optical detector, conventional - Black Page : 56
KCT731 Calibration Tool for KL731/DP331I Fire Detectors Page : 57
KL700A Analogue addressable ionisation sensor Page : 58
KL710A Analogue addressable temperature sensor Page : 59
KL731A Analogue addressable optical sensor (with field exchangeable chamber) Page : 60
KL731AB Analogue addressable optical detector - Black Page : 61
KL735A Analogue addressable dual (optical and thermal) sensor Page : 62
PG700 Fire sensor programmer Page : 63
KOB700 Replacement Optical Chamber for KL731/A & DP331I/1561 detectors Page : 64
KL7A Dust Protector Cover for KL700/A and Dx300/1500 detectors Page : 64
KZ700 Universal fire detector base Page : 65
KZ700B Universal fire detector base (for KL700/A and Dx300/1500) - Black Page : 66
KZ705 Universal fire detector base with earth connection Page : 67
S700 Surface mount accessory for KZ700 and KZ705 series bases Page : 67
KZ705I Analogue fire detector base with isolator Page : 68
KZ705AS Analogue fire detector base with sounder Page : 69
KZ705IAS Analogue fire detector base with isolator and sounder Page : 70
KZ705D Conventional fire detector base with diode Page : 71
KZ705R Conventional 12 VDC fire detector base with relay Page : 71
PA25/3L Low current remote LED indicator Page : 72
KAL410 Conventional Zone Monitor Unit - 1 Zone Page : 73
KAL414C Conventional Zone Monitor Unit - 4 Zones Page : 74
KAL426C Extinguishing Control Module Page : 75
KAL430 Relay Module - 1 Relay Page : 76
KAL434C Addressable Relay Module - 4 Relays Page : 77
KAL440 Supervised Relay Module Page : 78
KAL450 Addressable Manual Call Point Page : 79
DM715 EN54 universal glass for manual call point Page : 80
DM782 Hinged transparent MCP protection cover Page : 80
DM787 Surface mounting box with connectors, red Page : 81
KAL460 Digital Input Module Page : 82
KAL470 Isolator Module Page : 83
KAL490 Retention Module - 1 Input / 1 Output Page : 84
SK07A Addressable loop powered siren Page : 85
KR24B Illuminated warning sign (No text) 24VDC Page : 86
KR24-ING Illuminated extinguishing waring sign (English version) 24VDC Page : 87
SK07 Low consumption multi-tone alarm siren Page : 88
PCC-Config KSA701/FP1500 Configuration software kit Page : 89
PCG-Graphic102 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops) Page : 90
PCG-Graphic105 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-5 loops) Page : 91
PCG-GraphicNW Graphic Software for KSA700/FP1500 Fire Systems (multi-panel) Page : 92
KSP700 KSA702/5 Configuration software kit Page : 93
KSP701 PC Configuration RS232 Cable for KSA701/FP1500 fire panels Page : 94
PCC2000 Programming and configuration software Page : 95
PCG-N Graphics package network application with copy protection key Page : 96
PCG-S Graphics package with copy protection key Page : 97
PCM2000 Maintenance and support software with copy protection key Page : 98
ST801 High Temperature Thermal Probe with 2 wire connection Page : 99
ST802 High Temperature Thermal Probe with relay output Page : 100
CR255 Electronic delay control for double-leaf fire doors Page : 101
www.gesecurity.netAs a company of innovation, GE Security reserves the right to change product specifications without notice. For the latest productspecifications, visit GE Security online or contact your GE Security sales representative.