108
GE Security Kilsen Fire Systems Product Catalogue g

GE Fire Kilsen

  • Upload
    jebas11

  • View
    519

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GE Fire Kilsen

GESecurity

Kilsen Fire Systems Product Catalogue

g

Page 2: GE Fire Kilsen
Page 3: GE Fire Kilsen

In this catalogue you will find a wide range of

Fire Protection equipment from GE Security.

GE Security is a global technology leader dedicated

to supporting the needs of the rapidly growing

electronic security industry and to expanding

current technologies, products and services that

create revenue growth opportunities for its

customers. As part of the GE family, GE Security

shares the spirit of innovation that has

distinguished GE for well over 100 years. GE

Security's commitment to the ongoing success of

its partners and affiliates means that we maintain

a sharp focus on product and service innovation,

world-class manufacturing practices and

operational excellence.

GE Security is a worldwide organisation with sales

and technical support operations in 27 countries,

and manufacturing and logistics operations in

Europe, the U.S. and China.

GE Security has expertise in all areas of electronic

security, including:

Intrusion and Fire Protection

Electronic Access and Facility Management

Key Management and Remote Access Systems

and Services

Fibre Optic Transmission and Reception

Equipment

CCTV, Digital Video and Surveillance Equipment

Video Multiplexing and Digital Storage

When you're looking for the finest in Fire

Protection products with leading-edge

technology and the backing of a world leader, you

need look no further than this catalogue.

GE Security,unrivalled expertise in Fire Protection

Page 4: GE Fire Kilsen
Page 5: GE Fire Kilsen

Conventional Fire Systems

Page : 3

NKB602Conventional fire alarm panel with 2 zones

The NKB600 Series microprocessor controlled, conventional fire panelsincorporate state of the art technology, reliability, ease of installationand maintenance in a basic package. They are compatible withconventional detectors such as the Kilsen 200, 300, 500 and 700 seriesdevices. The NKB602 has 2 conventional zones.

Specifications

Supply Voltage 125/230 VAC @ 50/60 Hz

Mains fuse (Type 5x20 mm) 0.5/0.25 A

Total consumption < 20 W

Nominal Output Voltage 24 VDC

Batteries

Recommended batteries 2 off 1.9 Ah, 12 V

Fuse Rating 1 A

Maximum load current < 100 mA

Zone

Maximum Load 72 mA

Maximum number ofdetectors

20

Ouput voltage 22 to 28 VDC

End-of-line resitance 4k7 Ohm

Manual call point resistance 100 Ohm, 2 W

Outputs

Fire alarm 24 VDC ± 15%, 300 mA

Fault alarm (Fail-to-safe) 24 VDC ± 15%, 100 mA

Environmental

Working temperature +5 to +40°C

Storage temperature -10 to +70°C

Relative humidity 95 % (non-condencing)

Physical Characteristics

Size (w x h x d) 305 x 295 x 100 mm

Weight without batteries 3 kg

Ordering Information

Conventional fire alarm panel with 2 zonesNKB602

Modern, elegant designE

Compact models for 2, 4 and 6 zonesE

Microprocessor controlledE

Multilingual keyboardE

2 Access levelsE

Differentiation between alarms from manual call pointsand automatic detectors in the same zone

E

Acoustic indications for fire and faultE

Optical indications for fire and fault by zoneE

Low maintenanceE

Compatible with all ranges of KILSEN conventionaldetectors

E

Page 6: GE Fire Kilsen

Conventional Fire Systems

Page : 4

NKB604Conventional fire alarm panel with 4 zones

The NKB600 Series microprocessor controlled, conventional fire panelsincorporate state of the art technology, reliability, ease of installationand maintenance in a basic package. They are compatible withconventional detectors such as the Kilsen 200, 300, 500 and 700 seriesdevices. The NKB604 has 4 conventional zones.

Specifications

Supply Voltage 125/230 VAC @ 50/60 Hz

Mains fuse (Type 5x20 mm) 0.5/0.25 A

Total consumption < 20 W

Nominal Output Voltage 24 VDC

Batteries

Recommended batteries 2 off 1.9 Ah, 12 V

Fuse Rating 1 A

Maximum load current < 100 mA

Zone

Maximum Load 72 mA

Maximum number ofdetectors

20

Ouput voltage 22 to 28 VDC

End-of-line resitance 4k7 Ohm

Manual call point resistance 100 Ohm, 2 W

Outputs

Fire alarm 24 VDC ± 15%, 300 mA

Fault alarm (Fail-to-safe) 24 VDC ± 15%, 100 mA

Environmental

Working temperature +5 to +40°C

Storage temperature -10 to +70°C

Relative humidity 95 % (non-condencing)

Physical Characteristics

Size (w x h x d) 305 x 295 x 100 mm

Weight without batteries 3 kg

Ordering Information

Conventional fire alarm panel with 4 zonesNKB604

Modern, elegant designE

Compact models for 2, 4 and 6 zonesE

Microprocessor controlledE

Multilingual keyboardE

2 Access levelsE

Differentiation between alarms from manual call pointsand automatic detectors in the same zone

E

Acoustic indications for fire and faultE

Optical indications for fire and fault by zoneE

Low maintenanceE

Compatible with all ranges of KILSEN conventionaldetectors

E

Page 7: GE Fire Kilsen

Conventional Fire Systems

Page : 5

NKB606Conventional fire alarm panel with 6 zones

The NKB600 Series microprocessor controlled, conventional fire panelsincorporate state of the art technology, reliability, ease of installationand maintenance in a basic package. They are compatible withconventional detectors such as the Kilsen 200, 300, 500 and 700 seriesdevices. The NKB606 has 6 conventional zones.

Specifications

Supply Voltage 125/230 VAC @ 50/60 Hz

Mains fuse (Type 5x20 mm) 0.5/0.25 A

Total consumption < 20 W

Nominal Output Voltage 24 VDC

Batteries

Recommended batteries 2 off 1.9 Ah, 12 V

Fuse Rating 1 A

Maximum load current < 100 mA

Zone

Maximum Load 72 mA

Maximum number ofdetectors

20

Ouput voltage 22 to 28 VDC

End-of-line resitance 4k7 Ohm

Manual call point resistance 100 Ohm, 2 W

Outputs

Fire alarm 24 VDC ± 15%, 300 mA

Fault alarm (Fail-to-safe) 24 VDC ± 15%, 100 mA

Environmental

Working temperature +5 to +40°C

Storage temperature -10 to +70°C

Relative humidity 95 % (non-condencing)

Physical Characteristics

Size (w x h x d) 305 x 295 x 100 mm

Weight without batteries 3 kg

Ordering Information

Conventional fire alarm panel with 6 zonesNKB606

Modern, elegant designE

Compact models for 2, 4 and 6 zonesE

Microprocessor controlledE

Multilingual keyboardE

2 Access levelsE

Differentiation between alarms from manual call pointsand automatic detectors in the same zone

E

Acoustic indications for fire and faultE

Optical indications for fire and fault by zoneE

Low maintenanceE

Compatible with all ranges of KILSEN conventionaldetectors

E

Page 8: GE Fire Kilsen

Conventional Fire Systems

Page : 6

NK702Conventional fire panel with 2 fire alarm zones

The NK700 series of conventional fire alarm and extinguishing controlpanels is the ideal solution for small to medium-sized installations. Verypowerful and cost-effective, they are extremely simple to install anduse due to their ergonomic, advanced design. The NK704 has 4conventional zones.

Specifications

Supply voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 Hz

Batteries

Capacity 2 x 2.3 Ah

Fuse rating 2 A

Zone

Maximum load 94 mA

Max. number of detectors perzone

20

Maximum zone resistance 44 ohm

Sounders

Maximum load 250 mA

Delay Selectable 0 - 9 min

Relay outputs (excludingsounders)

1 A @ 30 VDC

Extinguishing relay outputs

Maximum load NA

Fuse rating NA

Auxilliary output 250 mA

24 VDC Resetable output

Maximum load 100 mA

Reset time 3 s

Environment

Working temperature -5 °C to +40 °C

Relative humidity 95 % (non condensing)

IP rating IP30

Physical characteristics

Size (mm) 297 (w) x 307 (h) x 105 (d)

Weight (without batteries) 3.6 kg

Ordering Information

Conventional fire panel with 2 fire alarm zonesNK702

Modern, attractive designE

Microprocessor-controlledE

From 2 up to 16-zonesE

EN54 approvedE

2 User access levelsE

2 Monitored sounder outputsE

One-man test capabilityE

24 Volt resetable outputE

External 'Class Change' facilityE

Alarm output with potential free relayE

Common fault output with potential free relay E

External watchdogE

Active end-of-line supportE

Addional optional modules with supervised or relayoutputs

E

Page 9: GE Fire Kilsen

Conventional Fire Systems

Page : 7

NK704Conventional fire panel with 4 fire alarm zones

The NK700 series of conventional fire alarm and extinguishing controlpanels is the ideal solution for small to medium-sized installations. Verypowerful and cost-effective, they are extremely simple to install anduse due to their ergonomic, advanced design. The NK704 has 4conventional zones.

Specifications

Supply voltage 230 VAC @ 50 Hz (±10%)

Batteries

Capacity 2 x 7.5 Ah

Fuse rating 1 A

Zone

Maximum load 72 mA

Max number of detectors 20

Sounders

Maximum load 300 mA

Relay outputs (excludingSounders)

2 A @ 250 V

Extinguishing relay outputs

Maximum load NA

Fuse rating NA

Open collector outputs 15 mA

Auxilliary output

Maximum load 300 mA

24 V resetable output

Maximum load 150 mA

Reset time 4 seconds

Delays

Sounder selectable 0.15 & 60 s

Relay module 3 to 180 s

Enviroment

Working temperature +5°C to +40 °C

Relative humidity 95 % (non-condensing)

Ordering Information

Conventional fire panel with 4 fire alarm zonesNK704

Modern, attractive designE

Microprocessor-controlledE

From 2 up to 16-zonesE

EN54 approvedE

2 User access levelsE

2 Monitored sounder outputsE

One-man test capabilityE

24 Volt resetable outputE

External 'Class Change' facilityE

Alarm output with potential free relayE

Common fault output with potential free relay E

External watchdogE

Active end-of-line supportE

Addional optional modules with supervised or relayoutputs

E

Page 10: GE Fire Kilsen

Conventional Fire Systems

Page : 8

NK708Conventional fire panel with 8 fire alarm zones

The NK700 series of conventional fire alarm and extinguishing controlpanels is the ideal solution for small to medium-sized installations. Verypowerful and cost-effective, they are extremely simple to install anduse due to their ergonomic, advanced design. The NK708 has 8conventional zones.

Specifications

Supply voltage (+10% - 15%) 230 / 110 VAC @ 50 / 60 Hz

Batteries

Capacity 2 x 7.5 Ah

Fuse rating 5 A

Zone

Maximum load 94 mA

Max. number of detectors perzone

20

Maximum zone resistance 44 ohm

Sounders

Maximum load 250 mA

Delay Selectable 0 - 9 min

Relay outputs (excludingsounders)

1 A @ 30 VDC

Extinguishing relay outputs

Maximum load NA

Fuse rating NA

Auxilliary output 250 mA

24 VDC Resetable output

Maximum load 100 mA

Reset time 3 s

Environment

Working temperature -5 °C to +40 °C

Relative humidity 95 % (non condensing)

IP rating IP30

Physical characteristics

Size (mm) 420 (w) x 335 (h) x 110 (d)

Weight (without batteries) 6.2 kg

Ordering Information

Conventional fire panel with 8 fire alarm zonesNK708

Modern, attractive designE

Microprocessor-controlledE

From 2 up to 16-zonesE

EN54 approvedE

2 User access levelsE

2 Monitored sounder outputsE

One-man test capabilityE

24 Volt resetable outputE

External 'Class Change' facilityE

Alarm output with potential free relayE

Common fault output with potential free relay E

External watchdogE

Active end-of-line supportE

Addional optional modules with supervised or relayoutputs

E

Page 11: GE Fire Kilsen

Conventional Fire Systems

Page : 9

NK712Conventional fire panel with 12 fire alarm zones

The NK700 series of conventional fire alarm and extinguishing controlpanels is the ideal solution for small to medium-sized installations. Verypowerful and cost-effective, they are extremely simple to install anduse due to their ergonomic, advanced design. The NK712 has 12conventional zones.

Specifications

Supply voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 Hz

Batteries

Capacity 2 x 7.5 Ah

Fuse rating 5 A

Zone

Maximum load 94 mA

Max. number of detectors perzone

20

Maximum zone resistance 44 ohm

Sounders

Maximum load 250 mA

Delay Selectable 0 - 9 min

Relay outputs (excludingsounders)

1 A @ 30 VDC

Extinguishing relay outputs

Maximum load NA

Fuse rating NA

Auxilliary output 250 mA

24 VDC Resetable output

Maximum load 100 mA

Reset time 3 s

Environment

Working temperature -5 °C to +40 °C

Relative humidity 95 % (non condensing)

IP rating IP30

Physical characteristics

Size (mm) 420 (w) x 335 (h) x 110 (d)

Weight (without batteries) 6.2 kg

Ordering Information

Conventional fire panel with 12 fire alarm zonesNK712

Modern, attractive designE

Microprocessor-controlledE

From 2 up to 16-zonesE

EN54 approvedE

2 User access levelsE

2 Monitored sounder outputsE

One-man test capabilityE

24 Volt resetable outputE

External 'Class Change' facilityE

Alarm output with potential free relayE

Common fault output with potential free relay E

External watchdogE

Active end-of-line supportE

Addional optional modules with supervised or relayoutputs

E

Page 12: GE Fire Kilsen

Conventional Fire Systems

Page : 10

NK716Conventional fire panel with 16 fire alarm zones

The NK700 series of conventional fire alarm and extinguishing controlpanels is the ideal solution for small to medium-sized installations. Verypowerful and cost-effective, they are extremely simple to install anduse due to their ergonomic, advanced design. The NK716 has 16conventional zones.

Specifications

Supply voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 Hz

Batteries

Capacity 2 x 7.5 Ah

Fuse rating 5 A

Zone

Maximum load 94 mA

Max. number of detectors perzone

20

Maximum zone resistance 44 ohm

Sounders

Maximum load 250 mA

Delay Selectable 0 - 9 min

Relay outputs (excludingsounders)

1 A @ 30 VDC

Extinguishing relay outputs

Maximum load NA

Fuse rating NA

Auxilliary output 250 mA

24 VDC Resetable output

Maximum load 100 mA

Reset time 3 s

Environment

Working temperature -5 °C to +40 °C

Relative humidity 95 % (non condensing)

IP rating IP30

Physical characteristics

Size (mm) 420 (w) x 335 (h) x 110 (d)

Weight (without batteries) 6.2 kg

Ordering Information

Conventional fire panel with 16 fire alarm zonesNK716

Modern, attractive designE

Microprocessor-controlledE

From 2 up to 16-zonesE

EN54 approvedE

2 User access levelsE

2 Monitored sounder outputsE

One-man test capabilityE

24 Volt resetable outputE

External 'Class Change' facilityE

Alarm output with potential free relayE

Common fault output with potential free relay E

External watchdogE

Active end-of-line supportE

Addional optional modules with supervised or relayoutputs

E

Page 13: GE Fire Kilsen

Conventional Fire Systems

Page : 11

NK703Conventional extinguishing control panel with 3 zones

The NK703 conventional fire alarm and extinguishing control panels isthe ideal solution for small to medium-sized installations. Very powerfuland cost-effective, they are extremely simple to install and use due totheir ergonomic, advanced design. It has 1 double-knock extinguisingarea consisting of two fire zones, and 1 free fire detection zone.

Specifications

Supply voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 Hz

Batteries

Capacity 2 x 7 Ah

Fuse rating 2 A

Zone

Maximum load 94 mA

Max. number of detectors perzone

20

Maximum zone resistance 44 ohm

Sounders

Maximum load 250 mA

Delay Selectable 0 - 9 min

Relay outputs (excludingsounders)

1 A @ 30 VDC

Extinguishing relay outputs

Maximum load 250 mA

Fuse rating 0.3 A

Auxilliary output 250 mA

24 VDC resetable ouput

Maximum load 100 mA

Reset time 3 s

Environment

Working temperature -5 °C to +40 °C

Relative humidity 95 % (non condensing)

IP rating IP30

Physical characteristics

Size (mm) 420 (w) x 335 (h) x 110 (d)

Weight (without batteries) 6.2 kg

Ordering Information

Conventional extinguishing control panel with 3 zonesNK703

Modern, attractive designE

Microprocessor controlledE

3 zone (1 ext. area) and 6 zone (2 ext. areas) availableE

Automatic extinguishing agent release controlE

2 Access levelsE

Supervised general sounder outputE

Supervised extinguishing inputs and outputsE

One-man test capabilityE

24 Volt resetable outputE

External 'class change' facilityE

Alarm output with potential free relayE

General fault output with potential free relay E

External watchdogE

Page 14: GE Fire Kilsen

Conventional Fire Systems

Page : 12

NK706Conventional extinguishing control panel with 6 zones

The NK706 conventional fire alarm and extinguishing control panels isthe ideal solution for small to medium-sized installations. Very powerfuland cost-effective, they are extremely simple to install and use due totheir ergonomic, advanced design. It has 2 double-knock extinguisingareas consisting of two fire zones each, and 2 free fire detection zones.

Specifications

Supply voltage (+10% - 15%) 230 VAC @ 50 Hz / 110 VAC @ 60 Hz

Batteries

Capacity 2 x 7 Ah

Fuse rating 2 A

Zone

Maximum load 94 mA

Max. number of detectors perzone

20

Maximum zone resistance 44 ohm

Sounders

Maximum load 250 mA

Delay Selectable 0 - 9 min

Relay outputs (excludingsounders)

1 A @ 30 VDC

Extinguishing relay outputs

Maximum load 250 mA

Fuse rating 0.3 A

Auxilliary output 250 mA

24 VDC resetable ouput

Maximum load 100 mA

Reset time 3 s

Environment

Working temperature -5 °C to +40 °C

Relative humidity 95 % (non condensing)

IP rating IP30

Physical characteristics

Size (mm) 420 (w) x 335 (h) x 110 (d)

Weight (without batteries) 6.2 kg

Ordering Information

Conventional extinguishing control panel with 6 zonesNK706

Modern, attractive designE

Microprocessor controlledE

3 zone (1 ext. area) and 6 zone (2 ext. areas) availableE

Automatic extinguishing agent release controlE

2 Access levelsE

Supervised general sounder outputE

Supervised extinguishing inputs and outputsE

One-man test capabilityE

24 Volt resetable outputE

External 'class change' facilityE

Alarm output with potential free relayE

General fault output with potential free relay E

External watchdogE

Page 15: GE Fire Kilsen

Conventional Fire Systems

Page : 13

RB404Relay module, 4 potential free relays for NK700/Fx400 fire panels

The RB404 relay expander module provides 4 additional voltage freerelays on the GE Security NK700/FP400/FEC400 conventional firepanels ranges. It allows for these relays to be allocated to individualdetection zones, or for programming the activation of different relaysdepending on the status of one or more zones. Up to 4 of thesemodules may be used on every fire panel.

Specifications

Relay rating

Voltage 250 VAC / 30 VDC

Current 10 A

Delay setting 0 to 9 minutes

Ordering Information

Relay module, 4 potential free relays for NK700/Fx400 fire panelsRB404

4 Potential free relaysE

Up to 4 modules may be housed inside the fire panelcabinet

E

Programmable with basic boolen functionsE

Power supplied from fire panel busE

Output delay setting per relayE

Page 16: GE Fire Kilsen

Conventional Fire Systems

Page : 14

SB404Relay module, 4 supervised relays for NK700/Fx400 fire panels

The SB404 expander module provides 4 additional supervised relaysthat provide 24 VDC outputs on the GE Security NK700/FP400/FEC400conventional fire panels ranges. These relays may be configured topower sounders or as standard 24 VDC supervised outputs for otherdevices. Relays may be allocated to individual detection zones, or forprogramming the activation of different relays depending on the statusof one or more zones. Up to 4 of these modulesmay be used on every fire panel.

Specifications

Auxiliary supply 24 VDC

Relay Rating

Voltage 250 VAC / 30 VDC

Current 5 A

Delay setting 0 to 9 minutes

Ordering Information

Relay module, 4 supervised relays for NK700/Fx400 fire panelsSB404

4 Supervised relaysE

Up to 4 modules may be housed inside the fire panelcabinet

E

Programmable with basic boolen functionsE

Output delay setting per relayE

Configurable for sounder control or as supervisedoutputs

E

Page 17: GE Fire Kilsen

Conventional Fire Systems

Page : 15

EOL-ACTActive end-of-line device for use with FP400/KL700 fire panels

The EOL-ACT is designed for use with the NK700/FP400 fire panels fromGE-Interlogix. It is an active end-of-line device to allow the monitoringof a conventional zone through a diode base (such as the KZ705D).

Ordering Information

Active end-of-line device for use with FP400/KL700 fire panelsEOL-ACT

SmallE

Easy to installE

Page 18: GE Fire Kilsen

Accessories

Page : 16

KLBlack-SBlack front panel cover (small footprint)

The KLBeige-S is a beige coloured, front panel housing lid for theFP200/NKB600, FP402 and FP404/NK702 and NK704 series fire panelsfrom GE Security. It allows the user to change the facure colour of thepanel for colour matching or renewal in case of damage.

Ordering Information

Black front panel cover (small footprint)KLBlack-S

Customisation of panel colour schemeE

Easy replacementE

KLBlack-BBlack front panel cover (large footprint)

The KLBlack-B is a black coloured, front panel housing lid for the FP408,FP412 and FP416/NK708, NK712 and NK716, the FEC400/NK703 andNK706, as well the FP1500/KSA701 series fire panels and repeatersfrom GE Security. It allows the user to change the facure colour of thepanel for colour matching or renewal in case of damage.

Ordering Information

Black front panel cover (large footprint)KLBlack-B

Customisation of panel colour schemeE

Easy replacementE

Page 19: GE Fire Kilsen

Addressable Fire Systems

Page : 17

KSA701-1Analogue addressable fire detection panel - 1 loop

The KSA701 analogue addressable fire alarm control panel is the idealsolution for small to medium-sized installations. Very powerful andcost-effective, it is extremely simple to install and use due to itsergonomic, advanced design. The panel is supplied in an elegant,high-quality, conveniently sized, heavy-duty enclosure. The cabinetallows for enough space for the batteries for the system to be housedinside the cabinet. The KSA701 is fully compatible with the Kilsen 700Aseries detectors and KAL400 series accessories.

Specifications

Supply voltage 110/230 VAC @ 50 Hz (+10% -15%)

Current consumption

(no devices connected) 175 mA Quiest. / 241 mA Alarm

Batteries

Capacity 2 x 12 V - 7 AH (SLA type)

Fuse rating 3 A

Charger (Temp. comp. -3 V /°C)

350 mA @ 27.6 VDC @ 20 °C

Loop characteristics per loop

Capacity 250 addresses

Maximum load 400 mA / 26 VDC to 32 VDC

Maximum electricalcharacteristics

44 Ohm / 500 nF

Sounders (reverse polaritysupervision)

Maximum load (2 Outputs) 250 mA each / 18 to 24 VDC

Delays (adjustable in 10 sintervals)

10 to 600 seconds

Relay outputs (potential free) 1 A @ 30 VDC

24 V Auxiliary output

Maximum load 250 mA @ 18 VDC to 28 VDC

Environment

Working temperature -5°C to +40 °C

Relative humidity(non-condensing)

0-95%

IP rating IP30

Physical characteristics

Size 420 mm (w) x 335 (h) x 110 (d)

Weight (without batteries) 6.2 kg

Ordering Information

Analogue addressable fire detection panel - 1 loopKSA701-1

4 x 40 characters LCD displayE

20 Display zonesE

EN54 compliant with approvals pendingE

2 User access levelsE

2 Monitored sounder outputsE

2 Programmable voltage free relaysE

24 Volt auxiliary outputE

I/O programming capabilities with Boolean functionsE

Day/night sensitivity settingsE

Coincidence within zonesE

Upload/download and graphic PC softwareE

Panel networkingE

Installation test capabilityE

Page 20: GE Fire Kilsen

Addressable Fire Systems

Page : 18

KSA701-2Analogue addressable fire detection panel - 2 loops

The KSA701 analogue addressable fire alarm control panel is the idealsolution for small to medium-sized installations. Very powerful andcost-effective, it is extremely simple to install and use due to itsergonomic, advanced design. The panel is supplied in an elegant,high-quality, conveniently sized, heavy-duty enclosure. The cabinetallows for enough space for the batteries for the system to be housedinside the cabinet. The KSA701 is fully compatible with the Kilsen 700Aseries detectors and KAL400 series accessories.

Specifications

Supply voltage 110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)

Current consumption

(no devices connected) 175 mA Quiescent / 241 mA in alarm

Batteries

Capacity 2 x 12 V - 7 AH (SLA type)

Fuse rating 3 A

Charger rating (Temp.compensated -3 V / °C)

350 mA @ 27.6 VDC @ 20 °C

Loop characteristics per loop

Capacity 250 addresses

Maximum load 400 mA / 26 VDC to 32 VDC

Maximum electricalcharacteristics

44 Ohm / 500 nF approximately 2 km of 1.5 mm2diameter cable

Sounders (reverse polaritysupervision)

Maximum load 250 mA each (2 Sounder outputs available) / 18 VDCto 24 VDC

Delays (software adjustable in10 second intervals)

10 to 600 seconds

Relay outputs (potential free) 1 A @ 30 VDC

24 V Auxiliary output

Maximum load 250 mA @ 18 VDC to 28 VDC

Environment

Working temperature -5°C to +40 °C

Relative humidity(non-condensing)

0-95%

IP rating IP30

Physical Characteristics

Size 420 mm (w) x 335 (h) x 110 (d)

Weight 6.2 kg without batteries / 10.7 kg with 2 x 7 Ahbatteries

Ordering Information

Analogue addressable fire detection panel - 2 loopsKSA701-2

4 x 40 characters LCD displayE

20 Display zonesE

EN54 compliant with approvals pendingE

4 User access levelsE

2 Monitored sounder outputsE

2 Programmable voltage free relaysE

24 Volt auxiliary outputE

I/O programming capabilities with Boolean functionsE

Day/night sensitivity settingsE

Coincidence within zonesE

Upload/download and graphic PC softwareE

Panel networkingE

Installation test capabilityE

Page 21: GE Fire Kilsen

Addressable Fire Systems

Page : 19

NC785RS485 expansion kit for KSA701/FP1500 fire panels

The NC785 RS485 expander allows for an easy upgrade to theKSA701/FP1500 series addressable fire panels. Each module adds anadditional industry standard RS485 communication port to the panel.This port could be used for communications with other network nodesin the fire panel network.

Specifications

Number of ports 1

Communications medium RS485

Technical specifications

Maximum cable length 1200 m

Communication speed 9600 baud

Cable CAT5 - twisted with screen

Termination resistance 150 Ohm

Ordering Information

RS485 expansion kit for KSA701/FP1500 fire panelsNC785

Industry standard RS485 communicationsE

No hardware configuration requiredE

Page 22: GE Fire Kilsen

Addressable Fire Systems

Page : 20

KSA701RKSA701 Series LCD Repeater (mains powered)

The KSA701R repeater allows the user to monitor and control panelsconnected to the KSA700 fire panel network via and RS485 link. Itdisplays 20 zones in alarm and fault on the face of the panel, whilst allsystem messages are displayed on the easy to read, LCD display.

Specifications

Supply voltage

AC version 110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)

DC version 24 VDC

Current consumption 175 mA Quiescent / 200 mA in alarm

Battery charger (AC version only)

Capacity 2 x 12 V - 7 AH (SLA type)

Fuse rating 3 A

Charger rating 350 mA @ 27.6 VDC @ 20 °C (Temperaturecompensated -3 V / °C)

Environment

Working temperature -5 °C to +40 °C

Relative humidity 95% (non condensing)

IP rating IP30

Physical characteristics

Size 420 mm (w) x 335 (h) x 110 (d)

Weight 6.2 kg without batteries / 10.7 kg with 2 x 7 Ahbatteries

Communication ports RS232 and RS485 standard

Ordering Information

KSA701 Series LCD Repeater (mains powered)KSA701R

Modern, attractive designE

4 x 40 characters LCD displayE

20 Display zonesE

3 User access levelsE

24 VDC or 230 VAC models availableE

Panel networkingE

Full system controlE

Page 23: GE Fire Kilsen

Addressable Fire Systems

Page : 21

KSA701R-24KSA701 Series LCD Repeater (24VDC powered)

The KSA701R repeater allows the user to monitor and control panelsconnected to the KSA700 fire panel network via an RS485 link. Itdisplays 20 zones in alarm and fault on the face of the panel, whilst allsystem messages are displayed on the easy to read, LCD display.

Specifications

Supply voltage

AC version 110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)

DC version 24 VDC

Current consumption 175 mA Quiescent / 200 mA in alarm

Battery charger (AC version only)

Capacity 2 x 12 V - 7 AH (SLA type)

Fuse rating 3 A

Charger rating 350 mA @ 27.6 VDC @ 20 °C (Temperaturecompensated -3 V / °C)

Environment

Working temperature -5 °C to +40 °C

Relative humidity 95% (non condensing)

IP rating IP30

Physical characteristics

Size 420 mm (w) x 335 (h) x 110 (d)

Weight 6.2 kg without batteries / 10.7 kg with 2 x 7 Ahbatteries

Communication ports RS232 and RS485 standard

Ordering Information

KSA701 Series LCD Repeater (24VDC powered)KSA701R-24

Modern, attractive designE

4 x 40 characters LCD displayE

20 Display zonesE

3 User access levelsE

24 VDC or 230 VAC models availableE

Panel networkingE

Full system controlE

Page 24: GE Fire Kilsen

Addressable Fire Systems

Page : 22

KSA705Analogue addressable fire panel (expandable to 5 loops)

The KSA700 Series analogue addressable fire panels offer leading-edgetechnology for the control of analogue addressable fire detectiondevices. Their unique user-friendly programming facilitate the idealcontrol environment for either simple or complex fire systems.

Specifications

Supply voltage 230 VAC @ 50 Hz (+10% -15%)

Current consumption

(no devices connected) 175 mA Quiest. / 241 mA Alarm

Batteries

Capacity 2 x 12 V - 6 AH (SLA type)

Fuse rating 4 A

Charger (Temp. comp. -3 V /°C)

350 mA @ 27.6 VDC @ 20 °C

Loop characteristics per loop

Capacity 250 addresses

Maximum load 400 mA / 26 VDC to 32 VDC

Maximum electricalcharacteristics

44 Ohm / 500 nF

Sounders (reverse polaritysupervision)

Maximum load (2 Outputs) 250 mA each / 18 to 24 VDC

Delays (adjustable in 10 sintervals)

10 to 600 seconds

Relay outputs (potential free) 1 A @ 30 VDC

24 V Auxiliary output

Maximum load 800 mA @ 18 to 28 VDC

Environment

Working temperature -5 °C to +40 °C

Relative humidity 95% (non condensing)

IP rating IP41

Physical characteristics

Size 480 mm (w) x 455 (h) x 140 (d)

Weight (without batteries) 13.6 kg

Ordering Information

Analogue addressable fire panel (expandable to 5 loops)KSA705

4-line, 40-character LCD displayE

Panel networking capabilityE

Graphic monitoring softwareE

Windows based up/download programming softwareE

Remote programming and maintenance via modemand TCP/IP

E

Repeater facilitiesE

Powerful auto-configuration functionsE

Simple program options with on-screen menu selectionE

EN54 compliantE

Page 25: GE Fire Kilsen

Addressable Fire Systems

Page : 23

KSA705PAnalogue addressable fire panel with printer (expandable to 5 loops)

The KSA700 Series analogue addressable fire panels offer leading-edgetechnology for the control of analogue addressable fire detectiondevices. Their unique user-friendly programming facilitate the idealcontrol environment for either simple or complex fire systems. TheKSA705P offers an additional internal printer facility.

Specifications

Supply voltage 230 VAC @ 50 Hz (+10% -15%)

Current consumption (no devicesconnect)

175 mA Quiescent / 241 mA in alarm

Batteries

Capacity 2 x 12 V - 6 AH (SLA type)

Fuse rating 4 A

Charger (Temp. comp. -3 V /°C)

350 mA @ 27.6 VDC @ 20 °C

Loop characteristics per loop

Capacity 250 addresses

Maximum load 400 mA / 26 VDC to 32 VDC

Maximum electricalcharacteristics

44 Ohm / 500 nF approximately 2 km of 1.5 mm2diameter cable

Sounders (reverse polaritysupervision)

Maximum load 250 mA each (2 Sounder outputs available) / 18 VDCto 24 VDC

Delays (adjustable in 10 sintervals)

10 to 600 seconds

Relay outputs (potential free) 1 A @ 30 VDC

24 V Auxiliary output

Maximum load 800 mA @ 18 VDC to 28 VDC

Environment

Working temperature -5 °C to +40 °C

Relative humidity 95% (non condensing)

IP rating IP41

Physical characteristics

Size 480 mm (w) x 455 (h) x 140 (d)

Weight 13.6 kg without batteries / 21.6 kg with 2 x 7 Ahbatteries

Ordering Information

Analogue addressable fire panel with printer (expandable to 5 loops)KSA705P

4-line, 40-character LCD displayE

Panel networking capabilityE

Graphic monitoring softwareE

Windows based up/download programming softwareE

Remote programming and maintenance via modemand TCP/IP

E

Repeater facilitiesE

Powerful auto-configuration functionsE

Simple program options with on-screen menu selectionE

EN54 compliantE

Page 26: GE Fire Kilsen

Addressable Fire Systems

Page : 24

KAL701Loop driver module for KSA702/705 control panels

The KAL701 1 loop expander allows for an easy upgrade to the KSA702and KSA705 analalogue addressable fire panels. Each module consistof a simple plug in card and requires no additional settings orconnections for full functionality. The KAL701 has loop isolatorssupplied on both drivers and allows full class-A loop functionality withup to 250 device addresses.

Specifications

Number of loops 1

Loop characteristics

Capacity 250 addresses

Maximum load 400 mA / 26 VDC to 32 VDC

Maximum electricalcharacteristics

44 Ohm / 500 nF

Maximum loop length 2 km

Ordering Information

Loop driver module for KSA702/705 control panelsKAL701

Expands the loop capabailities of the KSA702 andKSA705

E

Allows for the connection of an additional 250 devicesper unit

E

Two isolated drivers support full class-A operationE

No hardware configuration requiredE

KAL732RS232 communications module for KSA702/5 control panels

The KAL732 RS232 expander allows for an easy upgrade to the KSA702and KSA705 analalogue addressable fire panels. Each module adds anadditional industry standard RS232 communication port to the panel.This port could be used for communications with a PC or forconnections to a printer or modem.

Specifications

Number of ports 1

Communications medium RS232

Technical specifications

Maximum cable length 15 m

Communication speed 9600 baud

Cable 3 core with screen

Ordering Information

RS232 communications module for KSA702/5 control panelsKAL732Industry standard RS232 communicationsE

No hardware configuration requiredE

Page 27: GE Fire Kilsen

Addressable Fire Systems

Page : 25

KAL785RS485 communications module for KSA702/5 control panels

The KAL785 RS485 expander allows for an easy upgrade to the KSA702and KSA705 analalogue addressable fire panels. Each module adds anadditional industry standard RS485 communication port to the panel.This port could be used for communications with other network nodesin the fire panel network.

Specifications

Number of ports 1

Communications medium RS485

Technical specifications

Maximum cable length 1200 m

Communication speed 9600 baud

Cable CAT5 - twisted with screen

Termination resistance 150 Ohm

Ordering Information

RS485 communications module for KSA702/5 control panelsKAL785

Industry standard RS485 communicationsE

No hardware configuration requiredE

KAL791Protocol Converter RS232/485 - Kilsen / Johnsson Control

The KAL791 is a protocol converter for the integration of Kilsen KSA700analogue fire alarm systems into Johnsson Controls buildingmanagement systems. It requires a 24 VDC supply from an auxiliarypower supply source.

Specifications

Supply Voltage 24 VDC

Current Consumption

260 mAEnvironment

Working Temperature -5°C to +40 °C

Relative Humidity(non-condensing)

0-95%

IP Rating IP41

Physical Characteristics

Size 390 mm (w) x 420 (h) x 135 (d)

Weight 9.3 kg

Ordering Information

Protocol Converter RS232/485 - Kilsen / Johnsson ControlKAL791 RS232 communications module for KSA702/5 control panelsKAL732RS485 communications module for KSA702/5 control panelsKAL785

RS232 or RS485 port optionsE

Seemless integration with no additional programmingon the fire system

E

24 VDC SupplyE

Page 28: GE Fire Kilsen

Addressable Fire Systems

Page : 26

KSA1204Analogue fire panel, 2 loops upgradable to 4, 64 display zones

The KSA1204 allows for 2 addressble fire panel loops and 64 displayzones.

Specifications

Supply voltage 230 VAC (+10/-15%) 50 Hz

Supply current (max) 1.5 A

Min. supply current @ 24 VDC 0.2 A

Battery charger rating @ 27.6VDC

1.6 A

Total supply rating @ 27.6 VDC 2.5 A

Relay rating @ 24 VDC 2 A

Weight (no batteries) 8 kg

Dimensions (H x W x D) 440 x 444 x 125 mm

Ordering Information

Analogue fire panel, 2 loops upgradable to 4, 64 display zonesKSA1204 2-loop extension board for 1200/2000 series fire panelsLC1502LON700 driver for FP1200 / FP2000LON2000ARCNET RS485 network card with single RS485 interfaceNC2011ARCNET network card with single optical interface boardNC2051Dongle for 1200 series panel networkingNET1200Relay extension board for 1200/2000 series fire panelsRB2016 Modem kitMOD2000 Programming and configuration softwarePCC2000Maintenance and support software with copy protection keyPCM2000

One man maintenanceE

Maintenance warningE

Soak testE

On-line diagnostics and statisticsE

Power supply for 72 hour autonomyE

Floating background compensationE

Coincidence within and in between zonesE

Start-up default modeE

Upload/download configuration facilities with PCE

I/O programming including Boolean functionsE

EN54 p2 & 4 and VDS approvedE

2 or 4 class A loopsE

Page 29: GE Fire Kilsen

Addressable Fire Systems

Page : 27

KSA1208Addressable fire panel, 2-8 loops, 64-255 display zones upgradable

A versatile, powerful addressable fire panel, 2 to 8 loops, 16 to 64displayed zones with extensive I/O features. The fire panel can operatewithin a 31 panel network and can communicate with global repeatersand PC graphics. It supports all the 700 series LON devices andrepeaters using a seperate two wire bus. It is truly user-friendly andprovides a generous 8 x 40 backlit graphic display. I/O control is donevia powerful boolean I/O programing. Extensive maintenance featuresare provided standard. The KSA1200 series supports 1500 seriessensors and 400 series I/O units.

Specifications

Supply voltage 1 190 - 270 V ac

40 - 60 Hz160 VA max.

Supply voltage 2 21 - 27 V dc

Current consumption

Quiescent @ 24 V dc (equippedloop)

800 mA

Alarm current @ 24 V dc 1 A

Available auxiliary current inalarm

3 A

Battery charger rating @ 27.5 Vdc

3 A

Total supply rating @ 27.5 V dc 4 A

Relay rating @ 24 V dc 2 A

Weight (no batteries) 15 kg

Dimensions (mm) (H x W x D) 804 x 441 x 109

Ordering Information

Addressable fire panel, 2-8 loops, 64-255 display zones upgradableKSA1208

One man maintenanceE

Graphic maintenanceE

Maintenance warningE

Service reminder signalE

Soak testE

On-line diagnostics and statisticsE

Floating background compensationE

Day/night sensitivity settingE

Coincidence within and in between zonesE

Automatic timed and manual on/off zonesE

Start-up default modeE

Service switchE

Upload/download, remote maintenance and graphic PCsoftware

E

I/O programming including Boolean functionsE

ARCNET panel networkingE

EN54 approved; certified Bosec, VdS, NFA2PE

Networkable "black box" and "global zone" systemE

Full range of repeater panelsE

Full range of LON devicesE

Page 30: GE Fire Kilsen

Addressable Fire Systems

Page : 28

KSA1264RRepeater / emulator with 64 zone indications

A repeater / emulator with 64 displayed fire and fault zones, used inKSA1200 networked systems. The repeater is connected on the arcnetnetwork and can operate in a local or global repeater mode. An 80 x 40backlit graphic display and full indication and control keyboard isprovided standard.

Specifications

Supply voltage 230 Vdc

Current consumption 300 mA max

Weight 15 kg

Dimensions (mm) (H x W x D) 804 x 441 x 109

Ordering Information

Repeater / emulator with 64 zone indicationsKSA1264R

8 x 40 character graphic displayE

Arcnet network connection to KSA1200 series firepanels

E

Global repeater functionE

Comprehensive control and display functionsE

Emulation functionE

64 zones fire and fault displayedE

230 VAC operationE

Page 31: GE Fire Kilsen

Addressable Fire Systems

Page : 29

KSA12255RGlobal zone repeater, 64 zones expandable up to 255

A repeater/emulator with 64 fire and fault zones, expandable to 255,used in 1200/2000 series networked systems. The repeater isconnected on the arcnet network and can operate in a local or globalrepeater mode. An 80 x 40 character, backlit graphic display and fullindication and control keyboard is provided standard.

Specifications

Supply voltage 1 190 - 270 VAC

40- 60 Hz160 VA max.

Current consumption

Quiescent 800 mA

Alarm current @ 24 V dc 1 A

Available auxiliary current inalarm

3 A

Battery charger rating @ 27.5V dc

3 A

Total supply rating 4 A

Weight (no batteries) 15 kg

Dimensions (mm H x W x D) 804 x 441 x 109

Ordering Information

Global zone repeater, 64 zones expandable up to 255KSA12255R LON700 driver for FP1200 / FP2000LON2000RS485 network extension boardNE2011Fibre optic network extension boardNE205164-zone LED extension fire and fault LEDZE2064

On-line diagnostics and statisticsE

Upload/download, remote maintenance and graphic PCsoftware

E

I/O programming including Boolean functionsE

ARCNET panel networkingE

Full range of 700 series LON devicesE

Page 32: GE Fire Kilsen

Addressable Fire Systems

Page : 30

LC15022-loop extension board for 1200/2000 series fire panels

The LC1502 is a 2-loop extension board for 1200/2000 series firepanels. It allows for 2 additional class-A loops to be inserted into thefire panel, and supports up to 250 addressable loop devices per loop.

Specifications

Current consumption

Quiescent @ 24 VDC (Fullyequipped loop)

+ 150 mA (252 detectors)

Ordering Information

2-loop extension board for 1200/2000 series fire panelsLC1502

2 Class-A loopsE

Up to 250 devices per loop (protocol dependent)E

Supports various detector protocolsE

No hardware address requiredE

LON2000LON700 driver for FP1200 / FP2000

FP1200 / FP2000 seriesA LON700 driver that connects FP1200 / FP2000 fire panels to LON700devices

Ordering Information

LON700 driver for FP1200 / FP2000LON2000

Page 33: GE Fire Kilsen

Addressable Fire Systems

Page : 31

LON2000RLON driver for FP1200/2000 - closed loop systems

The LON2000R is a LON700 driver that connects 1200/2000 series firepanels to LON700 series devices on a closed loop, CLASS-A LON700network.

Ordering Information

LON driver for FP1200/2000 - closed loop systemsLON2000R

NC2011ARCNET RS485 network card with single RS485 interface

The NC2011 is an interface board to connect an RS485 copper networkdirectly into the 1200/2000 series fire panels. It is supplied with oneNE2011 pre installed.

Ordering Information

ARCNET RS485 network card with single RS485 interfaceNC2011RS485 network extension boardNE2011

Page 34: GE Fire Kilsen

Addressable Fire Systems

Page : 32

NC2051ARCNET network card with single optical interface board

The NC2051 is an interface board to connect a fiber optic networkdirectly into the 1200/2000 series fire panels. It is supplied with oneNE2051 pre installed.

Ordering Information

ARCNET network card with single optical interface boardNC2051Fibre optic network extension boardNE2051

NE2011RS485 network extension board

The NE2011 is a RS485 network extension board for the NC2011 toallow dual bus and closed ring networks.

Ordering Information

RS485 network extension boardNE2011

Page 35: GE Fire Kilsen

Addressable Fire Systems

Page : 33

NE2051Fibre optic network extension board

FP1200 / FP2000 seriesAn extension board for the NC2051 to allow a fibre optic ring bus

Ordering Information

Fibre optic network extension boardNE2051

PR2000Internal printer

The PR2000 is a panel mount, 40-column dot matrix printer to be usedwith the 1200/2000 series fire panels. It is supplied with all necessaryaccesories to allow easy installation into cabinets that allow for thisoption.

Ordering Information

Internal printerPR2000

Page 36: GE Fire Kilsen

Addressable Fire Systems

Page : 34

RB2016Relay extension board for 1200/2000 series fire panels

The RB2016 is an extension board for 1200/2000 series fire panels. Itallows for up to 18 additional potential free relays to be added into thefire panel cabinet. Depending on the size and hardware configurationof the panel, up to 4 RB2016s may be included in any panel.

Specifications

Relay Contact Rating 1 A @ 30 VDC / 0.3 A @ 110 VDC / 0.3 A @ 125 VAC

Ordering Information

Relay extension board for 1200/2000 series fire panelsRB2016

Up to 18 potential free relay outputsE

No hardware address requiredE

ZE206464-zone LED extension fire and fault LED

The ZE2064 allows the extension of the zones of the Fx2x128 andFx2x255 fire panels and repeaters by 64 additional zones.

Ordering Information

64-zone LED extension fire and fault LEDZE2064

Page 37: GE Fire Kilsen

LON700 Devices

Page : 35

FRL700LCD repeater

The LON700 LCD repeater is a smart and compact, cost-effectivesolution for fire panel repeaters. It is also available as an FBP700 firebrigade panel for Dutch and Scandinavian norms.

Specifications

Dimensions (l x w x d) 240 x 320 x 60 mm

Weight 1.5 kg

Operating temp °C -5°C to +40°C

Operating voltage 15 - 30 VDC

Current consumption

Max. quiesent 100 mA

Bus Connection two wire LON700

Bus Cable CAT 5

Total number of repeaters

700/1200/2000 Series 15

Ordering Information

LCD repeaterFRL700

2 wire connection between fire panel and repeatersE

Up to 1500 metre bus lengthE

24 Volt power supplyE

Cost effective repeater solutionsE

Easily installed, simple operationE

4 x 20 charater LCD display, common LED's, pushbutton control

E

LON700 moduleE

Page 38: GE Fire Kilsen

LON700 Devices

Page : 36

NA704LON700 network amplifier (4 way)

The NA704 is an interface board to allow an extension of the LON700network above its normal limitations. It acts as a network amplifierallowing for reconstruction and re-transmission of the LON700 signal,as well as allowing for T-offs of the network as required.

Ordering Information

LON700 network amplifier (4 way)NA704 LON700 driver for the NC771 and NA704NE771Fibre optic network extension boardNE2051

NC700LON700 interface board

The NC700 is an interface board to connect a LON700 bus from a firepanel to a FB7xx 'black box'.

Ordering Information

LON700 interface boardNC700

Page 39: GE Fire Kilsen

LON700 Devices

Page : 37

NC771LON700 closed loop communication board (no driver)

The NC771 is an interface board to connect a LON bus from a firepanel to a FB7xx 'black box' panel. It allows for full Class-A typeLON700 networks.

Ordering Information

LON700 closed loop communication board (no driver)NC771 LON700 driver for the NC771 and NA704NE771Fibre optic network extension boardNE2051

NE771LON700 driver for the NC771 and NA704

The NE771 is a LON700 network extension board to allow dual bus andclosed ring networks on the NC771 and the NA771.

Ordering Information

LON700 driver for the NC771 and NA704NE771

Page 40: GE Fire Kilsen

LON700 Devices

Page : 38

OCB724LON700 output board with 24 open collector outputs

The OCB724 is a 24 way open collector board used in a LON700system.

Ordering Information

LON700 output board with 24 open collector outputsOCB724

PS700Plug-in power supply 3.5 A

The PS700 power supply can be used to extend the power output inLON700 systems.

Ordering Information

Plug-in power supply 3.5 APS700

Page 41: GE Fire Kilsen

LON700 Devices

Page : 39

RB708LON700 output board with 8 relays

The RB708 is an eight way relay board used in LON700 systems.

Specifications

Number of outputs 8

Relay contact rating

Switching current 2A

Switching volage 42V ac/dc

Switching power 60W

Ordering Information

LON700 output board with 8 relaysRB708

SIB716Supervised input board 16 way LON700

The SIB716 is a sixteen way input board used in LON700 systems.

Ordering Information

Supervised input board 16 way LON700SIB716

Page 42: GE Fire Kilsen

LON700 Devices

Page : 40

SOB708LON700 output board with 8 supervised outputs

The SOB708 provides eight supervised outputs that can be used inLON700 systems.

Specifications

Number of outputs 8

Output type polarity reversal

End of line resistor 5.6 Kohm

Output current per output 500mA

Total current for all outputs 2A

Open circuit >27 Kohm

Normal 1.2 - 18 Kohm

Short circuit < 470 ohm

Ordering Information

LON700 output board with 8 supervised outputsSOB708

ZI7088 zone input extension board

The ZI708 is an eight zone input expansion board for LON700compatible systems. It allows for the connection of up to 8conventional fire detector zones and is compatible with most industrystandard conventional detectors.

Ordering Information

8 zone input extension boardZI708

Page 43: GE Fire Kilsen

Gas Detection

Page : 41

KM260/1R3-03CO detection control panel - 1 Zone (English Version)

The KM-Series CO detection system is designed for applications suchas vehicle parking areas where concentrations of CO may accumulate.The range is compliant with the UNE23.300/84 standard. The KM260/1is a 1 (upgradable to 2) zone control unit, using KM170 detectors.

Specifications

Power supply

Mains supply 230 VAC ±10% 50 Hz

Power consumption 95 W (max)

Zone configuration

Zone input voltage 10-20 VDC/VAC

Sensitiviy 0-300 ppm

Cable requirement 3 core 1.5 mm²

Cable length (max) 350 m

No. of detectors (max) 15

No. of zones (max) 2

Mechanical

Housing (w x h x d) 275 x 335 x 130 mm

Weight 6 kg

Ordering Information

CO detection control panel - 1 Zone (English Version)KM260/1R3-03

Designed according to norm 23300/84E

Miner CDM8001 and CDM8002 standard passwordE

LGAI 154.909 and 96013132 standard certificationE

Easy to useE

Low current consumptionE

Direct reading of measured levelsE

Easy installationE

Extraction relays and alarm outputs per areaE

From 1 to 5 areasE

3-wire systemE

Modular designE

Up to 15 detectors per zoneE

10 seconds response timeE

Elegant designE

Supervision of all zone linesE

Available in various languagesE

Page 44: GE Fire Kilsen

Gas Detection

Page : 42

KM260/3R3-03CO detection control panel - 3 Zones (English Version)

The KM-Series CO detection system is designed for applications suchas vehicle parking areas where concentrations of CO may accumulate.The range is compliant with the UNE23.300/84 standard. The KM260/3is a 3 (upgradable to 5) zone control unit, using KM170 detectors.

Specifications

Power supply

Mains supply 230 VAC ±10% 50 Hz

Power consumption 95 W (max)

Zone configuration

Zone input voltage 10-20 VDC/VAC

Sensitiviy 0-300 ppm

Cable requirement 3 core 1.5 mm²

Cable length (max) 350 m

No. of detectors (max) 15

No. of zones (max) 5

Mechanical

Housing (w x h x d) 470 x 335 x 130 mm

Weight 10.2 kg

Ordering Information

CO detection control panel - 3 Zones (English Version)KM260/3R3-03

Designed according to norm 23300/84E

Miner CDM8001 and CDM8002 standard passwordE

LGAI 154.909 and 96013132 standard certificationE

Easy to useE

Low current consumptionE

Direct reading of measured levelsE

Easy installationE

Extraction relays and alarm outputs per areaE

From 1 to 5 areasE

3-wire systemE

Modular designE

Up to 15 detectors per zoneE

10 seconds response timeE

Elegant designE

Supervision of all zone linesE

Available in various languagesE

Page 45: GE Fire Kilsen

Gas Detection

Page : 43

KM260EXT3-03CO detection expansion module (English Version)

The KM260 is an expansion module for the KM260-Series CO panelsfrom GE-Interlogix. It allows for an additional monitoring zone to beadded to the control panel, each module allowing for an additional 15sensors to be connected.

Specifications

Power supply

Mains supply 230 VAC ±10% 50 Hz

Power consumption 95 W (max)

Zone configuration

Zone input voltage 10-20 VDC/VAC

Sensitiviy 0-300 ppm

Cable requirement 3 core 1.5 mm²

Cable length (max) 350 m

No. of detectors (max) 15

No. of zones (max) 1

Ordering Information

CO detection expansion module (English Version)KM260EXT3-03 Designed according to norm 23300/84E

Miner CDM8001 and CDM8002 standard passwordE

LGAI 154.909 and 96013132 standard certificationE

Easy to useE

Low current consumptionE

Direct reading of measured levelsE

Easy installationE

Extraction relays and alarm outputs per areaE

3-wire systemE

Up to 15 detectors per zoneE

10 seconds response timeE

Supervision of zone lineE

Available in various languagesE

Page 46: GE Fire Kilsen

Gas Detection

Page : 44

KM260CBlanking plate for KM260 panels

The blanking plate is used on KM260 panels during upgrading ofmodules to cover up any unused positions that may exist on the panel.

Ordering Information

Blanking plate for KM260 panelsKM260C

Page 47: GE Fire Kilsen

Gas Detection

Page : 45

KM170CO detector with base and mounting supplement

The KM170 detector is specifically designed to react to the presence ofcarbon monoxide. The design complies with the requirements of theUNE 23-300 standard.

Specifications

Sensor type TGS semicondictor

Useful life 4 years

Electrical characteristics

Supply voltage 10 to 20 VDC

Quiescent current 35 mA

Reaction time 10 s

Environmental

Operating temperature 0 °C to +40 °C

Protection index IP205

Mechanical

Size (h x Ø) 81 x 109 mm

Weight 115 g

Material and colour ABS white

Installation

Number of detectors per zone 15

Covarage 300 m²

Ordering Information

CO detector with base and mounting supplementKM170

Complies with the requirements of the UNE23-300standard

E

Microprocessor basedE

Resolution of up to 5 ppmE

Response time of 10 sE

Low current consumptionE

Local status indication of:-Normal operation-50ppm detected-Fault

E

Useful life of up to 4 yearsE

Page 48: GE Fire Kilsen

Gas Detection

Page : 46

KZ400Detector base for KL400/KM170 series devices

The KZ400 base is designed to be used with the KL400 series detectors,but may also be used as a substitution base for KM170 CO detectors.

Specifications

Dimensions

Diameter 107 mm

Height 22 mm

Ordering Information

Detector base for KL400/KM170 series devicesKZ400

Polarity sensitiveE

Remote indicator contact availableE

S300Surface mount supplement for KL300/KM170 detectors

The S300 is a base accessory designed for use with the KZ300 andKZ400 detector base. It allows for a surface mount conduit and cableto enter the base from the side. The KZ300 and KZ400 base fits on topof this accessory. The S300 can also be used with KM170 CO detectors.

Specifications

Dimensions

Diameter 107 mm

Height 25 mm

Ordering Information

Surface mount supplement for KL300/KM170 detectorsS300

Surface mount accessory for KZ300E

May be used with KM170 CO DetectorsE

Page 49: GE Fire Kilsen

Aspiration Systems

Page : 47

ASD20CAspiration Smoke Detector

The ASD20 Aspiration Smoke Detector consists of an analysis chamberwith one or two smoke detectors, connected to standard 25 mm ØPVC piping. The detectors can be of conventional or analoguetechnology, ionisation or optical.

Specifications

Power supply voltage 24 VDC

Current Consumption

Standby 250 mA

1st alarm 280 mA

2nd alarm 320 mA

Fault 220 mA

Environmental Characteristics

Working temperature -10 to +60°C

Storage temperature -10 to +70°C

Relative humidity <95%

Physical Characteristics

Size 314 x 254 x 115

Weight 4 kg

Colour RAL9999

Material Polycarbonate

Cable input 3 x PG11

Wire cross-section Max. 1.5 mm²

Coverage area per intake 30 m²

Maximum num. of intakes 12

DIN 8062-type PVC pipes Ø25 mm

Useful lifetime of motor 65 000 hours at 40°C

Ordering Information

Aspiration Smoke DetectorASD20C Filter housing for ASD20ASD20FFilter only for ASD20ASD20FIL

Used with conventional or analogue detectorsE

Direct connection to an analogue loop or stand-aloneoperation

E

Alarm 1, alarm 2 and fault relay outputsE

24 VDC power supplyE

Simple and robust architectureE

30 m² coverage per sample intakeE

Standard 25 mm PVC piping systemE

Installation of piping in I-shape and U-shape(symmetrical or assymmetrical)

E

Continuous supervision of pipe flow volumeE

Page 50: GE Fire Kilsen

Aspiration Systems

Page : 48

ASD20FFilter housing for ASD20

The ASD20F is an aluminium filter housing for the ASD20 aspirationdetection system. It houses and protects the the air filter, the ASD20FIL,that has to be ordered seperately.

Ordering Information

Filter housing for ASD20ASD20F Filter only for ASD20ASD20FIL

Robust, light weight, aluminium constructionE

Easy to installE

Easy filter replacementE

ASD20FILFilter only for ASD20

Filter only for ASD20 Aspiration Detector.

Ordering Information

Filter only for ASD20ASD20FIL

Page 51: GE Fire Kilsen

Conventional Fire Systems

Page : 49

KV210Rate-of-Rise Heat Detector

The KV210 heat detectors are designed to activate when thetemperature exceeds a preset level or when the speed at which thetemperature changes is above a set threshold, even if the fixedactivation temperature point has not been reached. These detectorscomply to the UNE 23-007 part 5 standard.

Specifications

Operating voltage 16 to 28 VDC

Current consumption

Quiescent at 24 VDC < 100 A

Alarm at 24 VDC < 100 mA

Remote alarm output NA

Heat specification UNE 23.007/5 compliant

Working Area 20-30 m²

Installation Height (max.) 6 m

Operating temperature -10 to +60 °C

Storage temperature -10 to +70 °C

Humidity (non-condensing) 0 - 95%

IP rating IP205

Dimensions (h x Ø) 60 mm x 108 mm

Ordering Information

Rate-of-Rise Heat DetectorKV210

Very low standby currentE

Two-wire connectionE

No mechanical parts subject to wear and tearE

Rate-of-rise and thermostaticE

Remote indicator output on KV210PE

Latching alarmE

Compact and water resistant electronicsE

Highly resistant to humidity and corrosionE

Modern and elegant designE

No base requiredE

Excellent price/quality ratioE

Page 52: GE Fire Kilsen

Conventional Fire Systems

Page : 50

KV210PRate-of-Rise Heat Detectors with remote indicator output

The KV210 heat detectors are designed to activate when thetemperature exceeds a preset level or when the speed at which thetemperature changes is above a set threshold, even if the fixedactivation temperature point has not been reached. These detectorscomply to the UNE 23-007 part 5 standard. The KV210P has an outputfor a remote indicator.

Specifications

Operating voltage 16 to 28 VDC

Current consumption

Quiescent at 24 VDC < 100 A

Alarm at 24 VDC < 100 mA

Remote alarm output < 100 mA

Heat specification UNE 23.007/5 compliant

Working Area 20-30 m²

Installation Height (max.) 6 m

Operating temperature -10 to +60 °C

Storage temperature -10 to +70 °C

Humidity (non-condensing) 0 - 95%

IP rating IP205

Dimensions (h x Ø) 60 mm x 108 mm

Ordering Information

Rate-of-Rise Heat Detectors with remote indicator outputKV210P

Very low standby currentE

Two-wire connectionE

No mechanical parts subject to wear and tearE

Rate-of-rise and thermostaticE

Remote indicator output on KV210PE

Latching alarmE

Compact and water resistant electronicsE

Highly resistant to humidity and corrosionE

Modern and elegant designE

No base requiredE

Excellent price/quality ratioE

Page 53: GE Fire Kilsen

Conventional Fire Systems

Page : 51

KL500Low Profile Ionisation Smoke Detector

The KL500 ionisation smoke detector reacts to the presence of bothvisible and invisible combustion smoke, which makes it ideal for earlyfire detection, even before flames appear.

Specifications

Operating voltage 18 to 28 VDC

Current consumption

Quiescent at 24 VDC 30 mA

Alarm at 24 VDC < 70 mA

Radio-active source Americium 241

Average activity < 1mCi

Remote alarm output < 100 mA

Operating temperature -10 to +60 °C

Storage temperature -10 to +70 °C

Humidity (non-condensing) 0 - 95%

IP rating IP205

Dimensions (h x Ø)

Head 60 mm x 108 mm

Base 24 mm x 103 mm

Coverage 60 - 80 m²

Maximum installation height 12 m

Ordering Information

Low Profile Ionisation Smoke DetectorKL500 Fire detector base for KL500 detectorsKZ500Surface mount supplement for KL300/KM170 detectorsS300 Low current remote LED indicatorPA25/3L

Response to the full range of combustion smokeE

Low standby currentE

No mechanical parts subject to wear and tearE

High luminosity alarm indicatorE

Remote indicator output availableE

Latching alarmE

Two wire connectionE

Highly resistant to humidity and corrosionE

Modern and elegant designE

Easy installationE

More than 90% of materials recyclable (including theradio-active source)

E

Page 54: GE Fire Kilsen

Conventional Fire Systems

Page : 52

KZ500Fire detector base for KL500 detectors

The KZ500 is a detecor base for use with the KL500 detectors fromKilsen. It allows for a remote indicator to be connected.

Specifications

Dimensions

Diameter 108 mm

Height 18 mm

Ordering Information

Fire detector base for KL500 detectorsKZ500

Polarity sensitiveE

Remote indicator contact availableE

Page 55: GE Fire Kilsen

Conventional Fire Systems

Page : 53

KL700Ionisation detector, conventional

Of outstanding performance, efficiency and durability, the 700 seriesfire detectors are the ideal solution for conventional installations. Theyare designed specifically for use with the Kilsen NKB600, NK600 andNK700 series conventional fire panels, but are also compatible withmost 3rd party industry standard conventional control panels.

Specifications

Operating voltage 18 to 28 VDC

Current consumption

Quiescent at 24 VDC 30 A

Alarm at 24 VDC < 100 mA

Radio-active source Americium 241

Average activity 0.33 +/-0.04 Ci (12.1 +/- 1.5 kBq)

Remote alarm output < 100 mA

Heat specification

Operating temperature -10 to +60 °C

Storage temperature -10 to +70 °C

Humidity (non-condensing) 0 - 95%

IP rating IP43

Number of detectors per zone 20

Recommended protectionresistor

300 ohm

Dimensions (h x Ø)

Head 45 mm x 99 mm

Base 24 mm x 103 mm

Approvals* EN54 (BOSEC)

* Check current status with localoffice

Ordering Information

Ionisation detector, conventionalKL700 Universal fire detector base KZ700Universal fire detector base with earth connectionKZ705Conventional fire detector base with diodeKZ705D Low current remote LED indicatorPA25/3L

Full line consisting of Optical, Ionisation and Heatdetectors

E

An ultra-fine grid prevents the ingress of dust andinsects in smoke detectors

E

Attractive, low-profile designE

EN54 approved *E

Innovative base compensates for uneven surfacesE

Field exchangeable optical chamber for ease ofmaintenance

E

Page 56: GE Fire Kilsen

Conventional Fire Systems

Page : 54

KL710Temperature detector (fixed and rate-of-rise), conventional

Of outstanding performance, efficiency and durability, the 700 seriesfire detectors are the ideal solution for conventional installations. Theyare designed specifically for use with the Kilsen NKB600, NK600 andNK700 series conventional fire panels, but are also compatible withmost 3rd party industry standard conventional control panels.

Specifications

Operating voltage 18 to 28 VDC

Current consumption

Quiescent at 24 VDC 70 A

Alarm at 24 VDC < 100 mA

Radio-active source

Average activity

Remote alarm output < 100 mA

Heat specification Max. & ROR to EN54p5

Operating temperature -10 °C to +70 °C

Storage temperature -10 °C to +80 °C

Humidity (non-condensing) 95%

IP rating IP43

Number of detectors per zone 20

Recommended protectionresistor

300 ohm

Dimensions (h x Ø)

Head 45 mm x 99 mm

Base 24 mm x 103 mm

Approvals* EN54 (BOSEC)

* Check current status with localoffice

Ordering Information

Temperature detector (fixed and rate-of-rise), conventionalKL710 Universal fire detector base KZ700Universal fire detector base with earth connectionKZ705Conventional fire detector base with diodeKZ705D Low current remote LED indicatorPA25/3L

Full line consisting of Optical, Ionisation and Heatdetectors

E

An ultra-fine grid prevents the ingress of dust andinsects in smoke detectors

E

Attractive, low-profile designE

EN54 approved *E

Innovative base compensates for uneven surfacesE

Field exchangeable optical chamber for ease ofmaintenance

E

Page 57: GE Fire Kilsen

Conventional Fire Systems

Page : 55

KL731Optical detector, conventional (with field exchangeable optical block)

Of outstanding performance, efficiency and durability, the 700 seriesfire detectors are the ideal solution for conventional installations. Theyare designed specifically for use with the Kilsen NKB600, NK600 andNK700 series conventional fire panels, but are also compatible withmost 3rd party industry standard conventional control panels.

Specifications

Operating voltage 9 to 28 VDC

Current consumption

Quiescent at 24 VDC 85 A

Alarm at 24 VDC < 100 mA

Radio-active source

Average activity

Remote alarm output < 100 mA

Heat specification

Operating temperature -10 °C to +70 °C

Storage temperature -10 °C to +70 °C

Humidity (non-condensing) 95%

IP rating IP43

Number of detectors per zone 20

Recommended protectionresistor

300 ohm

Dimensions (h x Ø)

Head 45 mm x 99 mm

Base 24 mm x 103 mm

Approvals* EN54 (BOSEC)

* Check current status with localoffice

Ordering Information

Optical detector, conventional (with field exchangeable optical block)KL731 Replacement Optical Chamber for KL731/A & DP331I/1561 detectorsKOB700 Universal fire detector base KZ700Universal fire detector base with earth connectionKZ705Conventional fire detector base with diodeKZ705DConventional 12 VDC fire detector base with relayKZ705R Low current remote LED indicatorPA25/3L

An ultra-fine grid prevents the ingress of dust andinsects in smoke detectors

E

Attractive, low-profile designE

EN54 approvedE

Innovative base compensates for uneven surfacesE

Field exchangeable optical chamber for ease ofmaintenance

E

Page 58: GE Fire Kilsen

Conventional Fire Systems

Page : 56

KL731BOptical detector, conventional - Black

Of outstanding performance, efficiency and durability, the 700 seriesfire detectors are the ideal solution for conventional installations. Theyare designed specifically for use with the Kilsen NKB600, NK600 andNK700 series conventional fire panels, but are also compatible withmost 3rd party industry standard conventional control panels. TheKL731B is a black detector specifically designed for use in falseceilings.

Specifications

Operating voltage 9 to 28 VDC

Current consumption

Quiescent at 24 VDC 85 A

Alarm at 24 VDC < 100 mA

Radio-active source

Average activity

Remote alarm output < 100 mA

Heat specification

Operating temperature -10 °C to +70 °C

Storage temperature -10 °C to +70 °C

Humidity (non-condensing) 95%

IP rating IP43

Number of detectors per zone 20

Recommended protectionresistor

300 ohm

Dimensions (h x Ø)

Head 45 mm x 99 mm

Base 24 mm x 103 mm

Approvals* EN54 (BOSEC)

* Check current status with localoffice

Ordering Information

Optical detector, conventional - BlackKL731B Replacement Optical Chamber for KL731/A & DP331I/1561 detectorsKOB700

An ultra-fine grid prevents the ingress of dust andinsects in smoke detectors

E

Attractive, low-profile designE

EN54 certification marks (*)E

Field exchangable optical chamber for ease ofmaintenance

E

Black colour E

Page 59: GE Fire Kilsen

Conventional Fire Systems

Page : 57

KCT731Calibration Tool for KL731/DP331I Fire Detectors

The KCT731 is a calibration tool to recalibrate the conventionaldetectors after replacement of the field exchangeable optical block.

Specifications

Supply 2 x 9 V batteries

Dimensions (w x h x d) 104 x 195 x 63 mm

Ordering Information

Calibration Tool for KL731/DP331I Fire DetectorsKCT731

Easy to useE

Simple "go/no-go" functionE

Battery operatedE

Page 60: GE Fire Kilsen

Addressable Fire Systems

Page : 58

KL700AAnalogue addressable ionisation sensor

The KL700A Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrityand error free operation of the fire system, without compromisingspeed. All sensors are compatible with a standard base that makesthem easily interchangeable and that supports the connection of aremote indicator.

Specifications

Operating voltage 22 - 38 VDC

Current consumption

Quiescent @ 38 VDC 200 A

In alarm less than 11 mA

Alarm indication (Dual LED) White OFF - Red ON

Remote alarm output Available

Environment

Storage temperature -10 °C to +70 °C

Operating temperature -10 °C to +60 °C

Humidity (non condencing) 95%

IP rating IP205

Radioactive source 0.33 ± 0.04 Ci Am 241

Dimensions (h x Ø) 45 mm x 99 mm

Ordering Information

Analogue addressable ionisation sensorKL700A

Remote signalling capabilitiesE

Easy soft addressing (1-125)E

SMD technologyE

Reliable communication protocolE

Full diagnostic self testingE

Full range: Ionisation, Optical and Heat and Duelsensors (optical/heat)

E

Full range of supporting I/O units and accessoriesE

EN54 ApprovedE

Page 61: GE Fire Kilsen

Addressable Fire Systems

Page : 59

KL710AAnalogue addressable temperature sensor

The KL700A Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrityand error free operation of the fire system, without compromisingspeed. All sensors are compatible with a standard base that makesthem easily interchangeable and that supports the connection of aremote indicator.

Specifications

Operating voltage 22 - 38 VDC

Current consumption

Quiescent @ 38 VDC 250 A

In alarm less than 11 mA

Alarm indication (Dual LED) White OFF - Red ON

Remote alarm output Available

Environment

Storage temperature -10 °C to +80 °C

Operating temperature -10 °C to +70 °C

Humidity (non condencing) 95%

IP rating IP205

Radioactive source NA

Dimensions (H x Ø) 45 mm x 99 mm

Ordering Information

Analogue addressable temperature sensorKL710A

Remote signalling capabilitiesE

Fixed and Rate-of-Rise heat detectorsE

Easy soft addressing (1-125)E

SMD technologyE

Reliable communication protocolE

Full diagnostic self testingE

Full range: Ionisation, Optical and Heat and Duelsensors (optical/heat)

E

Full range of supporting I/O units and accessoriesE

EN54 ApprovedE

Page 62: GE Fire Kilsen

Addressable Fire Systems

Page : 60

KL731AAnalogue addressable optical sensor (with field exchangeable chamber)

The KL700A series detectors use a microprocessor for measurementand communication. An enhanced protocol ensures the overallintegrity and error free operation of the system, without compromisingdetection speed.

All sensors are compatible with a standard base that makes themeasily interchangeable and support the connection of the PA25/3Lremote indicator.

Specifications

Operating voltage 22 - 38 VDC

Current consumption

Quiescent @ 38 VDC 350 A

In alarm Less than 11 mA

Alarm indication (Dual LED) Red

Remote alarm output Available

Environment

Storage temperature -10 °C to +70 °C

Operating temperature -10 °C to +60 °C

Humidity (non condencing) 95%

IP rating IP205

Radioactive source NA

Dimensions (h x Ø) 45 mm x 99 mm

Ordering Information

Analogue addressable optical sensor (with field exchangeable chamber)KL731A Replacement Optical Chamber for KL731/A & DP331I/1561 detectorsKOB700 Universal fire detector base KZ700Universal fire detector base with earth connectionKZ705Analogue fire detector base with sounderKZ705ASAnalogue fire detector base with isolator and sounderKZ705IASAnalogue fire detector base with isolatorKZ705I Low current remote LED indicatorPA25/3L

Remote signalling capabilitiesE

Field exchangeable optical chamberE

Easy soft addressing (1-125)E

SMD technologyE

Reliable communication protocolE

Full diagnostic self testingE

Full range: Ionisation, Optical and Heat and Duelsensors (optical/heat)

E

Full range of supporting I/O units and accessoriesE

EN54 ApprovedE

Black ColourE

Page 63: GE Fire Kilsen

Addressable Fire Systems

Page : 61

KL731ABAnalogue addressable optical detector - Black

The KL700A Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrityand error free operation of the fire system, without compromisingspeed. All sensors are compatible with a standard base that makesthem easily interchangeable and that supports the connection of aremote indicator. The KL731B is a black detector specificlly designedfor false ceilings.

Specifications

Operating voltage 22 - 38 VDC

Current consumption

Quiescent @ 38 VDC 350 A

In alarm Less than 11 mA

Alarm indication (Dual LED) Red

Remote alarm output Available

Environment

Storage temperature -10 °C to +70 °C

Operating temperature -10 °C to +60 °C

Humidity (non condencing) 95%

IP rating IP205

Radioactive source NA

Dimensions (h x Ø) 45 mm x 99 mm

Ordering Information

Analogue addressable optical detector - BlackKL731AB Replacement Optical Chamber for KL731/A & DP331I/1561 detectorsKOB700

Remote signalling capabilitiesE

Field exchangeable optical chamberE

Easy soft addressing (1-125)E

SMD technologyE

Reliable communication protocolE

Full diagnostic self testingE

Full range: Ionisation, Optical and Heat and Duelsensors (optical/heat)

E

Full range of supporting I/O units and accessoriesE

EN54 ApprovedE

Black ColourE

Page 64: GE Fire Kilsen

Addressable Fire Systems

Page : 62

KL735AAnalogue addressable dual (optical and thermal) sensor

The KL700A Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrityand error free operation of the fire system, without compromisingspeed. All sensors are compatible with a standard base that makesthem easily interchangeable and that supports the connection of aremote indicator.

Specifications

Operating voltage 22 - 38 VDC

Current consumption

Quiescent @ 38 VDC 350 A

In alarm Less than 5 mA

Alarm indication (Dual LED) Red

Remote alarm output Available

Environment

Storage temperature -10 °C to +70 °C

Operating temperature -10 °C to +70 °C

Humidity (non condencing) 95%

IP rating IP42

Radioactive source NA

Dimensions (h x Ø) 51 mm x 99 mm

Ordering Information

Analogue addressable dual (optical and thermal) sensorKL735A

Remote signalling capabilitiesE

Fixed and Rate-of-Rise heat detectorsE

Easy soft addressing (1-125)E

SMD technologyE

Reliable communication protocolE

Full diagnostic self testingE

Full range: Ionisation, Optical and Heat and Duelsensors (optical/heat)

E

Full range of supporting I/O units and accessoriesE

EN54 ApprovedE

Page 65: GE Fire Kilsen

Addressable Fire Systems

Page : 63

PG700Fire sensor programmer

The PG700 is a handheld device programmer and tester for theKL700A/Dx1500 series detectors. It is battery operated and allows theinstaller to perform installation tasks (such as device addressing) andmaintenance tasks (such as device calibration) in the field withoutexternal assistance.

Specifications

Supply 2 x 9 V batteries

Dimensions (w x h x d) 104 x 195 x 63 mm

Ordering Information

Fire sensor programmerPG700

Easy to useE

Battery operatedE

4 User selectable programs-Device analogue value-Change Device Address-Sequential device addressing-KL731A Calibration

E

Page 66: GE Fire Kilsen

Detector Bases & Accessories

Page : 64

KOB700Replacement Optical Chamber for KL731/A & DP331I/1561 detectors

The KOB700 is an optical replacement chamber for KL731/KL731A andDP331I/DP1561 detectors. It is an inexpensive part that allows easymaintenance of these detectors on site without the need for cleaningsolvents or complicated cleaning procedures. Once replaced, thedetector performs as if it was a new device.

Specifications

Dimensions (Ø x h) 65 x 19 mm

Ordering Information

Replacement Optical Chamber for KL731/A & DP331I/1561 detectorsKOB700

InexpensiveE

Easy replacementE

Reduces maintenance timeE

No additional tools requiredE

KL7ADust Protector Cover for KL700/A and Dx300/1500 detectors

The KL7A is a dust protector cover for the KL700/DI322I andKL731/DP331I conventional, as well as the KL700A/DP1552 andKL731A/DP1561A addressable detectors. It allows for the protection ofthe detector chamber against the ingress of dust from buildingmaterials during construction or renovation of the building.

Ordering Information

Dust Protector Cover for KL700/A and Dx300/1500 detectorsKL7A

Negligible costE

Easy to install and removeE

Avoids unnecessary contamination of the detectorduring building works

E

Page 67: GE Fire Kilsen

Detector Bases & Accessories

Page : 65

KZ700Universal fire detector base

The KZ700 is a 4 contact universal detector base. It has the ability tocompensate for uneven mounting surfaces. It is also available in blackfor special applications in false ceilings.

Specifications

Dimensions

Diameter 104 mm

Height 24 mm

Ordering Information

Universal fire detector base KZ700Universal fire detector base (for KL700/A and Dx300/1500) - BlackKZ700B

Polarity sensitiveE

Universal base fits conventional and analoguedetectors

E

Compensates for uneven surfacesE

Remote indicator contact availableE

EN54 approvedE

Variant in black also availableE

Page 68: GE Fire Kilsen

Detector Bases & Accessories

Page : 66

KZ700BUniversal fire detector base (for KL700/A and Dx300/1500) - Black

The KZ700B is a black 4 contact universal detecor base for use with theKL700/Dx300 and KL700A/Dx1500 series detectors from GE-Interlogix.It has the ability to compensate for uneven mounting surfaces.

Specifications

Dimensions

Diameter 104 mm

Height 24 mm

Ordering Information

Universal fire detector base (for KL700/A and Dx300/1500) - BlackKZ700B

Polarity sensitiveE

Universal base fits conventional and analoguedetectors

E

Compensates for uneven surfacesE

Remote indicator contact availableE

EN54 approvedE

Variant in black also availableE

Page 69: GE Fire Kilsen

Detector Bases & Accessories

Page : 67

KZ705Universal fire detector base with earth connection

The KZ705 is a 5 contact universal detector base for use with theKL700/Dx300 and KL700A/Dx1500 series detectors from GE-Interlogix.In addition to the normal base and remote indication connectors, theKZ705 also has an additional earth terminal connector to allow foreasy terminations of a possible cable screen.

Specifications

Dimensions (Ø x h) 100 x 29 mm

Operating Voltage -

Current Consumption -

Isolation Current -

Isolation Resistance -

Sounder Frequency -

Sound Output

@ 3 mA -

@ 5 mA -

Environmental Characteristics

Operating Temperature -10 to 70 °C

Storage Temperature -10 to 70 °C

Relative Humidity (max) 95 % (non-cond.)

Ordering Information

Universal fire detector base with earth connectionKZ705

Polarity sensitiveE

Universal base fits conventional and analoguedetectors

E

Additional earth terminal availableE

Remote indicator contact availableE

S700Surface mount accessory for KZ700 and KZ705 series bases

The S700 is a base accessory designed for use with the KZ700 seriesdetector bases. It allows for a surface mount conduit and cable toenter the base from the side. The KZ700 series base fits on top of thisaccessory.

Specifications

Dimensions

Diameter 95 mm

Height 30 mm

Ordering Information

Surface mount accessory for KZ700 and KZ705 series basesS700

Surface mount accessory for KZ700 series basesE

Page 70: GE Fire Kilsen

Addressable Fire Systems

Page : 68

KZ705IAnalogue fire detector base with isolator

The KZ705I is a detector base with built in isolator for use with theKL700A/Dx1500 series detectors from GE-Interlogix. The isolatorprotects the loop from short circuit conditions. A LED on the side of thebase indicates the status of the isolator.

Specifications

Dimensions (Ø x h) 100 x 29 mm

Operating Voltage 17 - 34 V

Current Consumption 50 A

Isolation Current 6 mA

Isolation Resistance 140 Mohm

Sounder Frequency -

Sound Output

@ 3 mA -

@ 5 mA -

Environmental Characteristics

Operating Temperature -10 °C to +70 °C

Storage Temperature -10 °C to +70 °C

Relative Humidity (max) 95 % (non cond.)

Ordering Information

Analogue fire detector base with isolatorKZ705I

Polarity sensitiveE

Universal base for analogue detectorsE

Additional earth terminal availableE

Remote indicator contact availableE

Built in isolatorE

Page 71: GE Fire Kilsen

Addressable Fire Systems

Page : 69

KZ705ASAnalogue fire detector base with sounder

The KZ705AS is a detector base with built in analogue addressablesounder for use with the KL700A/Dx1500 series detectors fromGE-Interlogix. The sounder has its own address on the fire panel loopand works independent of the detector. It is fully controlled from thefire panel.

Specifications

Dimensions (Ø x h) 120 x 58 mm

Operating Voltage 22 - 38 V

Current Consumption 300 A Quiescent

Isolation Current -

Isolation Resistance -

Sounder Frequency 1 kHz (Continuous)

Sound Output

@ 3 mA 85 dBA

@ 5 mA 90 dBA

Environmental Characteristics

Operating Temperature -10 °C to +70 °C

Storage Temperature -10 °C to +70 °C

Relative Humidity (max) 95 % (non cond.)

IP Rating IP21c

Ordering Information

Analogue fire detector base with sounderKZ705AS

Polarity sensitiveE

Universal base for analogue detectorsE

Additional earth terminal availableE

Remote indicator contact availableE

Built in sounderE

Up to 90 dBA sound outputE

Low current consumptionE

Page 72: GE Fire Kilsen

Addressable Fire Systems

Page : 70

KZ705IASAnalogue fire detector base with isolator and sounder

The KZ705IAS is a detector base with built in analogue addressablesounder and isolator for use with the KL700A/Dx1500 series detectorsfrom GE-Interlogix. The sounder has its own address on the fire panelloop and works independent of the detector. It is fully controlled fromthe fire panel. The isolator protects the loop from short circuitconditions.

Specifications

Dimensions (Ø x h) 120 x 58 mm

Operating Voltage 22 - 38 V

Current Consumption 350 A Quiescent

Isolation Current 6 mA

Isolation Resistance 140 Mohm

Sounder Frequency 1 kHz (Continuous)

Sound Output

@ 3 mA 85 dBA

@ 5 mA 90 dBA

Environmental Characteristics

Operating Temperature -10 °C to +70 °C

Storage Temperature -10 °C to +70 °C

Relative Humidity (max) 95 % (non cond.)

IP Rating IP21c

Ordering Information

Analogue fire detector base with isolator and sounderKZ705IAS

Polarity sensitiveE

Universal base for analogue detectorsE

Additional earth terminal availableE

Remote indicator contact availableE

Built in sounderE

Up to 90 dBA sound outputE

Low current consumptionE

Built in isolatorE

Page 73: GE Fire Kilsen

Conventional Fire Systems

Page : 71

KZ705DConventional fire detector base with diode

The KZ705D is a 5 contact universal detector base for use with theKL700/Dx300 series detectors from GE-Interlogix. In addition to thenormal base and remote indication connectors, the KZ705D also hasan additional earth terminal connector to allow for easy terminationsof a possible cable screen. The built in diode is specifically targeted atsystems using active end-of-line devices.

Specifications

Dimensions (Ø x h) 100 x 29 mm

Operating Voltage -

Current Consumption -

Isolation Current -

Isolation Resistance -

Sounder Frequency -

Sound Output

@ 3 mA -

@ 5 mA -

Environmental Characteristics

Operating Temperature -10 to 70 °C

Storage Temperature -10 to 70 °C

Relative Humidity (max) 95 % (non-cond.)

Ordering Information

Conventional fire detector base with diodeKZ705D

Polarity sensitiveE

Universal base for conventional detectorsE

Additional earth terminal availableE

Remote indicator contact availableE

Built in diode for active end-of-line systemsE

KZ705RConventional 12 VDC fire detector base with relay

The KZ705R is a 5 contact detector base for use with the KL731/DP331Idetectors from GE-Interlogix. In addition to the normal base andremote indication connectors, the KZ705R also has an additional earthterminal connector to allow for easy terminations of a possible cablescreen. A built in 12 V relay makes it ideal for use on low voltageintrusion systems.

Specifications

Dimensions (Ø x h) 100 x 29 mm

Operating Voltage 12 V ± 10%

Current Consumption 12 A

Isolation Current -

Isolation Resistance -

Sounder Frequency -

Sound Output

@ 3 mA -

@ 5 mA -

Environmental Characteristics

Operating Temperature -10 °C to +70 °C

Storage Temperature -10 °C to +70 °C

Relative Humdity 95 % (non cond.)

Ordering Information

Conventional 12 VDC fire detector base with relayKZ705R

Polarity sensitiveE

12 V relay for 4 wire systemsE

Additional earth terminal availableE

Remote indicator contact availableE

Page 74: GE Fire Kilsen

Annunciators

Page : 72

PA25/3LLow current remote LED indicator

The PA25 remote indicators have been designed for direct connectionto fire detectors (conventional and analogue), enabling luminousindication outside the area where the detector is installed.

Specifications

Electrical Specifications

Supply Voltage (Analogue) 5 to 10 VDC

Current Consumption 2 to 79 mA

Supply Voltage (Conventional) 2 to 5 VDC

Current Consumption 6.5 to 61.5 mA

Mechanical Specifications

Size (w x h x d) 80 x 80 x 42 mm

Weight 10 g

Box material A.B.S.

Colour White

Environmental Specifications

Protection level IP20

Working temperature -10 to +60 °C

Storage temperature -10 to +70 °C

Ordering Information

Low current remote LED indicatorPA25/3L

Direct two-wire connection to detectorE

Large angle of visibility - lit up on four sidesE

Low current consumptionE

Flashing optionE

2 to 10 VDC power supplyE

High luminosityE

Compatible with third party productsE

IP20 protection levelE

Modern and elegant designE

ABS plastic casing with ruby red polycarbonatespy-hole

E

Shock resistantE

Page 75: GE Fire Kilsen

Addressable Fire Systems

Page : 73

KAL410Conventional Zone Monitor Unit - 1 Zone

Allows the connection of one conventional zone to the analogue firesystem loop. This zone is constantly monitored. Up to 20 conventionaldevices may be connected to this zone.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 90 A

Quiescent @ 35 V 105 A

Alarm < 3 mA

Aux. supply (24 VDC)quiescent

200 A + equip

Aux. supply (24 VDC) alarm < 85 mA

End-of-line resistor 4.7 kohm

Relay contact rating NA

Environmental

Storage temperature -10 °C to +50°C

Operating temperature -10 °C to +70°C

Relative humidity 95 % (non condensing)

Dimensions (L x W x H) 117 x 80 x 44 mm

Ordering Information

Conventional Zone Monitor Unit - 1 ZoneKAL410

Easy numeric addressingE

Continuous supervision of the conventional zonesE

Surface mountE

Local alarm indicationE

Externally or loop poweredE

Aesthetically pleasingE

Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control

E

Page 76: GE Fire Kilsen

Addressable Fire Systems

Page : 74

KAL414CConventional Zone Monitor Unit - 4 Zones

Allows the connection of four conventional zones to the analogue firesystem loop. These zones are constantly monitored. Up to 20conventional devices may be connected to any zone.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 110 A

Quiescent @ 35 V 135 A

Alarm < 5 mA

Aux. Supply (24V DC)Quiescent

200 A + equip

Aux. Supply (24V DC) Alarm < 360 mA

End-of-line resistor 4.7 kOhm

Relay contact rating NA

Environmental

Storage temperature -10 to +50°C

Operating temperature -10 to +70°C

Relative humidity(non-condensing)

0-95 %

Dimensions (l x w x h) 163 x 107 x 36 mm

Ordering Information

Conventional Zone Monitor Unit - 4 ZonesKAL414C

Easy numeric addressingE

Continuous supervision of the conventional zonesE

Surface mountE

Local alarm indicationE

Externally poweredE

Aesthetically pleasingE

Part of a family of I/O modules consisting of:E

- Conventional Zone MonitorsE

- Digital Input ModulesE

- Extinguishing Control ModulesE

- Isolator ModulesE

- Manual Call PointsE

- Output UnitsE

- Retention UnitsE

- Supervised Output Units for sounder controlE

Page 77: GE Fire Kilsen

Addressable Fire Systems

Page : 75

KAL426CExtinguishing Control Module

The 400 Series modules consists of a complete range of interfacesdeveloped for input/output control in the KSA700/FP1500 analogue firesystems from GE Interlogix. The KAL426 allows for the connection andcontrol of one extinguishing area to the addressable fire panel loop.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 110 A

Quiescent @ 35 V 210 A

Alarm < 10 mA

Aux. supply (24 VDC)quiescent

120 mA

Aux. supply (24 VDC) alarm < 1 A

End-of-line resistor 4.7 kOhm

Relay contact rating 2½ A

Environmental

Storage temperature -10 °C to +50°C

Operating temperature -10 °C to +70°C

Relative humidity 95 % (non condensing)

Dimensions (L x W x H) 163 x 107 x 36 mm

Ordering Information

Extinguishing Control ModuleKAL426C

Aesthetically pleasingE

Easy numeric addressingE

Externally poweredE

Supervised I/OE

Surface mountE

Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control

E

Page 78: GE Fire Kilsen

Addressable Fire Systems

Page : 76

KAL430Relay Module - 1 Relay

Provides for one potential free relay output for the fire system loop.Each relay allows for COMMON, NORMALLY OPEN and NORMALLYCLOSED contacts. The output may be used to activate ventilationcontrols, warning signs, activation of other alarm devices etc. duringfire situations.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 70 A

Quiescent @ 35 V 100 A

Alarm < 3.5 mA

Aux. 24 VDC quiescent 22 mA

Aux. 24 VDC alarm < 50 mA

End-of-line resistor NA

Relay contact rating 2½A @ 250 VAC

Environmental

Storage temperature -10 °C to +50°C

Operating temperature -10 °C to +70°C

Relative humidity 95 % (non condensing)

Dimensions (L x W x H) 117 x 80 x 44 mm

Ordering Information

Relay Module - 1 RelayKAL430

Easy numeric addressingE

Externally or loop poweredE

Normally open / normally closed operation for I/OE

Surface mountE

Aesthetically pleasingE

Local status indicationE

Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control

E

Page 79: GE Fire Kilsen

Addressable Fire Systems

Page : 77

KAL434CAddressable Relay Module - 4 Relays

Provides for four potential free relay outputs for the fire system loop.Each relay allows for COMMON, NORMALLY OPEN and NORMALLYCLOSED contacts. The outputs may be used to activate ventilationcontrols, warning signs, activation of other alarm devices etc. duringfire situations.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 110 A

Quiescent @ 35 V 135 A

Alarm 10 mA

Aux. 24VDC Quiescent 100 A

Aux. 24VDC Alarm 10 mA

End-of-line resistor NA

Relay contact rating 2½A @ 250 VAC

Environmental

Storage temperature -10 to +50°C

Operating temperature -10 to +70°C

Relative humidity (non-cond.) 0-95 %

Dimensions (l x w x h) 163 x 107 x 36 mm

Ordering Information

Addressable Relay Module - 4 RelaysKAL434C

Easy numeric addressingE

Externally poweredE

Normally open / normally closed operation for I/OE

Surface mountE

Aesthetically pleasingE

Local status indicationE

Part of a family of I/O modules consiting of:E

- Conventional Zone MonitorsE

- Digital Input ModulesE

- Extinguishing Control ModulesE

- Isolator ModulesE

- Manual Call PointsE

- Output UnitsE

- Retention UnitsE

- Supervised Output Units for sounder controlE

Page 80: GE Fire Kilsen

Addressable Fire Systems

Page : 78

KAL440Supervised Relay Module

Allows for the supervision of a single, 24 Volt powered output contacton the fire system loop. This unit may be used to control for e.g.sounders in case of fire conditions, but may also be used to switch anyoutput considered crucial enough to have the cable integrity betweenthe unit and the switch point monitored.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 110 A

Quiescent @ 35 V 135 A

Alarm < 3.6 mA

Aux. 24 VDC quiescent 23 mA

Aux. 24 VDC alarm 23 mA + equip

End-of-line resistor 4.7 kohm

Relay contact rating 1¼ A @ 250 VAC

Environmental

Storage temperature -10 °C to +50°C

Operating temperature -10 °C to +70°C

Relative humidity 95 % (non condensing)

Dimensions (L x W x H) 117 x 80 x 44 mm

Ordering Information

Supervised Relay ModuleKAL440

Easy numeric addressingE

Externally poweredE

Supervised 24 VDC Output E

Surface mountE

Aesthetically pleasingE

Local status indicationE

Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control

E

Page 81: GE Fire Kilsen

Addressable Fire Systems

Page : 79

KAL450Addressable Manual Call Point

The 400 Series modules consists of a complete range of interfacesdeveloped for input/output control in the KSA700/FP1500 analogue firesystems from GE Interlogix. The KAL450 is an addressable manual callpoint for manual fire activation.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 90 A

Quiescent @ 35 V 120 A

Alarm < 3.5 mA

Aux. supply (24 VDC)quiescent

NA

Aux. supply (24 VDC) alarm NA

End-of-line resistor NA

Relay contact rating NA

Environmental

Storage temperature -10 °C to +70°C

Operating temperature -10 °C to +50°C

Relative humidity 95 % (non condensing)

Ingress Protection IP20

Dimensions (L x W x H) 87 x 87 x 20 mm

Weight 98 g

Ordering Information

Addressable Manual Call PointKAL450EN54 universal glass for manual call pointDM715Terminal tray for MCPDM780GS cardDM781Hinged transparent MCP protection coverDM782BZB black bezelDM783Test keyDM784Spacer box, redDM785Surface mounting box with connectors, redDM787Surface mount box without connectors, redDM788Flush mount cradle with connectorsDM790Flush mount cradle, connectors & forkgripsDM795Breakable seal for MCPDM798Terminal tray ETT/3 with bezel 3DM799Resettable element for MCP DM700/KAL450DM800

Easy numeric addressingE

Loop poweredE

Local test facilityE

Surface or flush mountE

Aesthetically pleasingE

Local status indicationE

Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control

E

Wide range of accessoriesE

Page 82: GE Fire Kilsen

Manual Call Points

Page : 80

DM715EN54 universal glass for manual call point

The DM715 is a universal EN54 approved break glass for the DM700series and KAL450 manual call points.

Ordering Information

EN54 universal glass for manual call pointDM715Resettable element for MCP DM700/KAL450DM800

Plastic coated to prevent operator injuryE

No glass fragments on breakingE

No hammer requiredE

Approved EN54 part 11E

DM782Hinged transparent MCP protection cover

The DM782 anti-tamper plastic cover is a protection cover for theDM700 and KAL450 manual call points. It prevents accidentalactivation of the alarm by enforcing a two step action i.e. lifting thecover, then activating the alarm.

Ordering Information

Hinged transparent MCP protection coverDM782Breakable seal for MCPDM798

UnobtrusiveE

TransparentE

Protects from accidental alarm activationE

Page 83: GE Fire Kilsen

Manual Call Points

Page : 81

DM787Surface mounting box with connectors, red

The DM787 is surface mounting back-box for DM700 series andKAL450 series manual call points. The DM787 is red and has 3 wiringterminals

Specifications

Material Self-extinguishing Noryl SE100

Colour Red - RAL N°3020

Operating temperature -40° to +85°C

Relative humidity max. 90% RV

Ordering Information

Surface mounting box with connectors, redDM787Surface mounting box with connectors, yellowDM787YSurface mounting box with connectors, blueDM787BSurface mounting box with connectors, greenDM787GSurface mount box without connectors, redDM788

Easy to installE

For flush mounting of manual call pointsE

Three terminalsE

Page 84: GE Fire Kilsen

Addressable Fire Systems

Page : 82

KAL460Digital Input Module

Provides a remote input to the fire system loop. The input is constantlymonitored and its status communicated to the fire control panel. Theinput may be activated by closing or opening a potential free contact,depending on the module configuration.

This module may be used to monitor any contact by showing its statusthrough the fire control panel e.g. the monitoring of pressureequipment and closure fire break doors.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 110 A

Quiescent @ 35 V 135 A

Alarm < 10 mA

Aux. 24 VDC quiescent 200 A

Aux. 24 VDC alarm < 50 mA

End-of-line resistor NA

Relay contact rating NA

Environmental

Storage temperature -10 °C to +50°C

Operating temperature -10 °C to +70°C

Relative humidity 95 % (non condensing)

Dimensions (L x W x H) 117 x 80 x 44 mm

Ordering Information

Digital Input ModuleKAL460

Easy numeric addressingE

Externally or loop poweredE

Normally open / normally closed operation for I/OE

Surface mountE

Aesthetically pleasingE

Local status indicationE

Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control

E

Page 85: GE Fire Kilsen

Addressable Fire Systems

Page : 83

KAL470Isolator Module

The 400 series modules consist of a complete range of interfacesdeveloped for input/output control in the KSA700/FP1500 analogue firesystems from GE Interlogix. The KAL470 is an isolator module in thisseries that isolates the faulty zone on a fire panel loop during shortcircuit conditions. The KAL470 does not use an address on the loop.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 110 A

Quiescent @ 35 V 135 A

Alarm 10 mA

Aux. supply (24 VDC)quiescent

NA

Aux. supply (24 VDC) alarm NA

End-of-line resistor NA

Relay contact rating NA

Environmental

Storage temperature -10 °C to +50°C

Operating temperature -10 °C to +50°C

Relative humidity 95 % (non condensing)

Dimensions (L x W x H) 75 x 45 x 28 mm

Ordering Information

Isolator ModuleKAL470

Requires no device addressE

Automatic resetE

Local status indicationE

Surface mountE

Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control

E

Page 86: GE Fire Kilsen

Addressable Fire Systems

Page : 84

KAL490Retention Module - 1 Input / 1 Output

Provides a remote input and a potential free voltage relay output tothe fire system loop. The input signal is constantly monitored and itsstatus displayed on the control panel, whilst the output is fail-to-safe.Auxiliary supply monitoring is also included.

The module is used to for e.g. control and monitor doors such as firebreak doors. The relay provides the door activation and the inputmonitors the door status.

Specifications

Supply voltage 22-38 VDC

Current consumption

Quiescent @ 24 V 110 A

Quiescent @ 35 V 135 A

Alarm 10 mA

Aux. 24 VDC quiescent 200 A

Aux. 24 VDC alarm < 50 mA

End-of-line resistor NA

Relay contact rating 1A @ 30 VAC/VDC

Environmental

Storage temperature -10 °C to +50°C

Operating temperature -10 °C to +70°C

Relative humidity 95 % (non condensing)

Dimensions (L x W x H) 117 x 80 x 44 mm

Ordering Information

Retention Module - 1 Input / 1 OutputKAL490

Easy numeric addressingE

Externally or loop poweredE

Normally open / normally closed operation for I/OE

Surface mountE

Aesthetically pleasingE

Local status indicationE

Part of family of I/O modules consisting of:-Conventional Zone Monitors-Digital Input Modules-Extinguishing Control Modules-Isolator Modules-Manual Call Points-Output Units-Retention Units-Supervised Output Units for sounder control

E

Page 87: GE Fire Kilsen

Addressable Fire Systems

Page : 85

SK07AAddressable loop powered siren

The SK07A loop powered siren is designed for connection to andcontrol by the KSA700/FP1500 analogue fire detection systems fromGE-Interlogix. Communication is done digitally between the fire paneland the sounder.

Specifications

Electrical

Supply Voltage 22 - 38 VDC

Quiescent current 300 A

Alarm current 6 mA

Maximum sound level 87 dBA

Mechanical

Dimensions 63 mm (h) x 93 mm Ø

Maximum cable size 2.5 mm²

Fastening Screws 2 x 30 mm

Environmental

Working temperature -20 °C to +50 °C

Storage temperature -20 °C to +70 °C

Relative humidity (maximum) 95 %

Protection Index IP445

Ordering Information

Addressable loop powered sirenSK07A

EN54 part 3 compliantE

Up to 87 dBA sound outputE

Low current consumptionE

Low profileE

IP445 protection levelE

Easy installationE

Polarity sensitiveE

Rear and side cable entry possibleE

Low and easy maintenanceE

Page 88: GE Fire Kilsen

Annunciators

Page : 86

KR24BIlluminated warning sign (No text) 24VDC

The KR24 is specifically designed as an evacuation warning sign forgas extinguising areas. The KR24B has no text on the backlit display,and text may therefor be added as required for the application. Unitssupplied with text in various languages are also available.

Specifications

Electrical Specifications

Supply Voltage 18 to 27 VDC

Activation Voltage 18 to 27 VDC

Current Consumption 600 mA

Switching Polarity NA

Indicators 24 V 3 W

Environmental Specifications

Working Temperature -10 to 75 °C

Physical Specifications

Number of zones NA

Buzzer output 80 dB

Housing Colour Grey

Display Colour Red

Weight 700 g

Size (w x h x d) 255 x 110 x 50 mm

IP Rating IP50

Ordering Information

Illuminated warning sign (No text) 24VDC KR24B

Low current consumptionE

Large angle of viewE

Optical and acoustic indications selectableE

Modern and elegant designE

Page 89: GE Fire Kilsen

Annunciators

Page : 87

KR24-INGIlluminated extinguishing waring sign (English version) 24VDC

The KR24 is a backlit "No Entry / Extinguishing Release" warning sign tobe used with gas extinguishing areas. Warning text is available invarious languages.

Specifications

Electrical Specifications

Supply Voltage 18 to 27 VDC

Activation Voltage 18 to 27 VDC

Current Consumption 600 mA

Switching Polarity NA

Indicators 24 V 3 W

Environmental Specifications

Working Temperature -10 to 75 °C

Physical Specifications

Number of zones NA

Buzzer output 80 dB

Housing Colour Grey

Display Colour Red

Weight 700 g

Size (w x h x d) 255 x 110 x 50 mm

IP Rating IP50

Ordering Information

Illuminated extinguishing waring sign (English version) 24VDC KR24-ING

Low ConsumptionE

Large angle of visionE

Optical and acoustic indication selectable E

Modern and elegant designE

Page 90: GE Fire Kilsen

Annunciators

Page : 88

SK07Low consumption multi-tone alarm siren

The SK07 multi-tone siren is designed to sound an acoustic alarminside buildings. This small, low profile siren combines a high soundoutput with low power consumption. It complies with the requirementsof EN 54 part 3.

Specifications

Electrical

Supply Voltage 22 - 26 VDC

Alarm current 3 mA at 85 dBA or less than 20 mA at 95 dBA

Maximum sound level 95 dBA

Working temperature -20 °C to 50 °C

Storage temperature -20 °C to 70 °C

Maximum relative humidity 95 % (non condencing)

Mechanical

Dimensions 63 mm (h) x 93 mm Ø

Protection Index IP445

Fastening screws 2 x 30 mm

Maximum cable section 2.5 mm²

Recommended cable size Single core 1.5 mm²

Ordering Information

Low consumption multi-tone alarm sirenSK07

Low profileE

Easy installationE

Back and side cable entryE

Polarity sensitiveE

Connection base includedE

Input and output terminals includedE

Acoustic power output selectionE

Up to 95 dBA sound outputE

Eight different alarm tonesE

Automatic tone changeE

Low current consumptionE

Low maintenanceE

IP445 protection levelE

EN54 part 3 compliantE

Page 91: GE Fire Kilsen

Addressable Fire Systems

Page : 89

PCC-ConfigKSA701/FP1500 Configuration software kit

PCC-Config allows easy, menu driven, programming of all the featuresand settings of the panel. Common texts can be easily copied tosensors and zones. Programming becomes simple as all settings aredisplayed for the programmers convenience.

Specifications

Hardware requirements

Communication RS232, modem and/or TCP/IP

Display VGA or higher resolution

Hard disk 2 Gb with 650 Mb free space

Keyboard Required

Pointing device Required

Printer System printer required for printing

Processor 133 MHz or higher Pentium-compatible CPU

RAM 64 Mb or more

Removable media 1.44 Mb stiffy and CD-ROM or DVD drive

Software requirements

Operating system Win '98, Win 2000, Win XP

Ordering Information

KSA701/FP1500 Configuration software kitPCC-ConfigKSA702/5 Configuration software kitKSP700

Windows based E

Complete external configuration of the installationE

Configuration possibilities for single and networked firesystems

E

Local or remote operation via modem or TCP/IPE

Standard RS232 communicationE

Page 92: GE Fire Kilsen

Addressable Fire Systems

Page : 90

PCG-Graphic102Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops)

The PCG-Config series consists of 3 software applications. Theindividual software formats allows the graphic package to grow withthe installation. PCG-Config102 operates with a single panel and allowsfor the configuration of all devices up to a maximum of two loops.

Specifications

Hardware requirements

Communication RS232, modem and/or TCP/IP

Display SVGA or higher resolution

Hard disk 2 Gb with 650 Mb free space

Keyboard Required

Pointing device Required

Printer System printer required for printing

Processor 1 GHz or higher Pentium III-compatible CPU

RAM 256 Mb or more

Removable media 1.44 Mb stiffy and CD-ROM or DVD drive

Software requirements

Operating system Windows '98 or Windows 2000

Ordering Information

Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops)PCG-Graphic102

Bi-directional communication with single panels andnetworked fire systems

E

Local or remote connection via modem or TCP/IPE

Large selection of user configurable iconsE

Visualises device alarms and status of in- and outputsE

Event texts retrieval from the panelE

Configurator and operator contol levelsE

Navigation buttons allowedE

Event logs with reporting facilitiesE

Basic drawing package includedE

Imports bmp & drw format graphicsE

Page 93: GE Fire Kilsen

Addressable Fire Systems

Page : 91

PCG-Graphic105Graphic Software for KSA700/FP1500 Fire Systems (1 panel-5 loops)

The PCG-Config series consists of 3 software applications. Theindividual software formats allows the graphic package to grow withthe installation. PCG-Config105 supports a single panel up to 5 loops.

Specifications

Hardware requirements

Communication RS232, modem and/or TCP/IP

Display SVGA or higher resolution

Hard disk 2 Gb with 650 Mb free space

Keyboard Required

Pointing device Required

Printer System printer required for printing

Processor 1 GHz or higher Pentium III-compatible CPU

RAM 256 Mb or more

Removable media 1.44 Mb stiffy and CD-ROM or DVD drive

Software requirements

Operating system Windows '98 or Windows 2000

Ordering Information

Graphic Software for KSA700/FP1500 Fire Systems (1 panel-5 loops)PCG-Graphic105Bi-directional communication with single panels andnetworked fire systems

E

Local or remote connection via modem or TCP/IPE

Large selection of user configurable iconsE

Visualises device alarms and status of in- and outputsE

Event texts retrieval from the panelE

Configurator and operator contol levelsE

Navigation buttons allowedE

Event logs with reporting facilitiesE

Basic drawing package includedE

Imports bmp & drw format graphicsE

Page 94: GE Fire Kilsen

Addressable Fire Systems

Page : 92

PCG-GraphicNWGraphic Software for KSA700/FP1500 Fire Systems (multi-panel)

The PCG-Config series consists of 3 software applications. Theindividual software formats allows the graphic package to grow withthe installation. PCG-ConfigNW allows for monitoring on networkedsystems with multiple panels.

Specifications

Hardware requirements

Communication RS232, modem and/or TCP/IP

Display SVGA or higher resolution

Hard disk 2 Gb with 650 Mb free space

Keyboard Required

Pointing device Required

Printer System printer required for printing

Processor 1 GHz or higher Pentium III-compatible CPU

RAM 256 Mb or more

Removable media 1.44 Mb stiffy and CD-ROM or DVD drive

Software requirements

Operating system Windows '98 or Windows 2000

Ordering Information

Graphic Software for KSA700/FP1500 Fire Systems (multi-panel)PCG-GraphicNW

Bi-directional communication with single panels andnetworked fire systems

E

Local or remote connection via modem or TCP/IPE

Large selection of user configurable iconsE

Visualises device alarms and status of in- and outputsE

Event texts retrieval from the panelE

Configurator and operator contol levelsE

Navigation buttons allowedE

Event logs with reporting facilitiesE

Basic drawing package includedE

Imports bmp & drw format graphicsE

Page 95: GE Fire Kilsen

Addressable Fire Systems

Page : 93

KSP700KSA702/5 Configuration software kit

The KSP700 provides for a interface for the Kilsen KSA702 and KSA705analogue addressable fire panels for the up/downloading of the firepanel configuration software from a PC. It is supplied as a kit, includingthe configuration cable together with PCC-Config, the softwareconfiguration program for these panels.

Specifications

Hardware requirements

Communication RS232, modem and/or TCP/IP

Display VGA or higher resolution

Hard disk 2 Gb with 650 Mb free space

Keyboard Required

Pointing device Required

Printer System printer required for printing

Processor 133 MHz or higher Pentium-compatible CPU

RAM 64 Mb or more

Removable media 1.44 Mb stiffy and CD-ROM or DVD drive

Software requirements

Operating system Win '98, Win 2000, Win XP

Ordering Information

KSA702/5 Configuration software kitKSP700

Windows based E

Complete external configuration of the installationE

Configuration possibilities for single and networked firesystems

E

Local or remote operation via modem or TCP/IPE

Communications interface includedE

Page 96: GE Fire Kilsen

Addressable Fire Systems

Page : 94

KSP701PC Configuration RS232 Cable for KSA701/FP1500 fire panels

The KSP701 is a RS232 cable for connecting the KSA701 Series orFP1500 Series fire panels to an industry standard RS232 port on anyPC. It is normaly included with all software applications for thesepanels, but may also be ordered seperately when required.

Ordering Information

PC Configuration RS232 Cable for KSA701/FP1500 fire panelsKSP701

Complete RS232 cable with connectorsE

Page 97: GE Fire Kilsen

Addressable Fire Systems

Page : 95

PCC2000Programming and configuration software

PCC2000 allows easy, menu driven, programming of all the panel'sfeatures and settings. Common texts can be easily copied whilesensors, zones and areas increment or follow automatically. Booleanlogic programming becomes simple as inputs and outputs arecontinuously displayed for the programmer's convenience.

Specifications

Processor 486 66 MHz

RAM 12 Mb

Display adapter VGA

Hard disk space 20 MB

Pointing device MS Mouse

Graphical environment Windows 98, 2000, XP

Communications ports 1 x RS232

1 x Parallel

Ordering Information

Programming and configuration softwarePCC2000

Provide communication with single fire panels andnetworked fire systems, both locally or remote viamodem

E

Windows 98, 2000 and XP compatibleE

For use with 2000/1200 series panelsE

Menu drivenE

Full or partial up- and downloadE

Page 98: GE Fire Kilsen

Addressable Fire Systems

Page : 96

PCG-NGraphics package network application with copy protection key

2 Packages allow the graphic package to grow with the installation.The basic version PCG-S operates with a single panel, while the PCG-Nsupports a network. Upgrades do not require rework on the existingdatabase, drawings, etc.

Specifications

Processor Pentium II 266 MHz (or better)

RAM 64 Mb (or more)

Display adapter SVGA or better

Hard disk space 200 MB

Pointing device MS Mouse, Bus or P/S2

Graphical environment Windows NT

Communication ports 1 x RS-232 - Depending on drivers

1 x Parallel - Printer port (for key)

Ordering Information

Graphics package network application with copy protection keyPCG-N

Provide bi-directional communication with single firepanels and networked fire systems, both locally andremote via modem

E

Windows 2000 and NT compatibleE

For use with FP2000, FP1200, FP1100 and FP700E

Constructed around Sybase SQL AnywhereE

Large selection of iconsE

Visualises inputs & outputsE

Information page per pointE

Get texts from panelE

Several operator levels and passwordsE

Operator configurableE

Multiple navigation buttonsE

Event logsE

Basic drawing package includedE

Imports .bmp & .wmf drawings from virtually anypackage

E

Hardware key protectedE

Page 99: GE Fire Kilsen

Addressable Fire Systems

Page : 97

PCG-SGraphics package with copy protection key

2 Packages allow the graphic package to grow with the installation.The basic version PCG-S operates with a single panel, while the PCG-Nsupports a network. Upgrades do not require rework on the existingdatabase, drawings, etc.

Specifications

Item Recommended

Processor Pentium II 266 MHz (or better)

RAM 64 Mb (or more)

Display adapter SVGA or better

Hard disk space 200 MB

Pointing device MS Mouse, Bus or P/S2

Graphical environment Windows NT

Communication ports 1 x RS-232 - Depending on drivers

1 x Parallel - Printer port (for key)

Ordering Information

Graphics package with copy protection keyPCG-S

Provide bi-directional communication with single firepanels and networked fire systems, both locally andremote via modem

E

Windows 2000 and NT compatibleE

For use with FP2000, FP1200, FP1100 and FP700E

Constructed around Sybase SQL AnywhereE

Large selection of iconsE

Visualises inputs & outputsE

Information page per pointE

Get texts from panelE

Several operator levels and passwordsE

Operator configurableE

Multiple navigation buttonsE

Event logsE

Basic drawing package includedE

Imports .bmp & .wmf drawings from virtually anypackage

E

Hardware key protectedE

Page 100: GE Fire Kilsen

Addressable Fire Systems

Page : 98

PCM2000Maintenance and support software with copy protection key

PCM2000 allows local and remote maintenance facilities for 1200/2000series fire panels. Amongst others, it allows for full panel emulation,data retrieval and central alarm monitoring.

Specifications

Processor Pentium 133Mhz (or better)

RAM 32 Mb (or more)

Display Adapter VGA

Hard Disk Space 20 MB

Pointing Device Bus or P/S2 Mouse

Graphical Environment Windows 98, NT or 2000

Communications ports Depending on Drivers Printer port (for key)

1 Parallel

Ordering Information

Maintenance and support software with copy protection keyPCM2000

Provide communication with single fire panels andnetworked fire systems, both locally or remote viamodem

E

Windows 95, 98 and NT compatibleE

For use with FP2000, FP1200E

Full panel emulationE

Data retrievalE

Central stationE

History logE

Address bookE

Dynamic Link Library (DLL) for third party integrationE

Page 101: GE Fire Kilsen

Special Temperature Detectors

Page : 99

ST801High Temperature Thermal Probe with 2 wire connection

The ST801 thermal probe high temperature heat detector is designedto protect from hazards where high temperatures are produced at aspecific point. The sensitive element (bulb) can be set at a distance ofup to 1 meter from the connection box. The ST801 may be connectedvia 2 wires directly to a conventional fire panel zone.

Specifications

Suppy Voltage 24 VDC

Current Consumption

Quiescent Ø

Alarm 100 mA

Alarm Monitoring Two wires to conventional zone

Capilliary pipe length 1 m

Probe Dimentions (l x Ø) 150 x 3 mm

Dimensions 140 x 100 x 70 mm

Colour Grey RAL7032

Working Temperature 50 °C to 300 °C

Weight 0.8 kg

Ordering Information

High Temperature Thermal Probe with 2 wire connectionST801

Completely metalE

Adjustable from 50 to 300 °CE

Back and side cable inputE

Sensitive probe with 1 m of stainless steel capillarypiping

E

Resistant to heat, grease and humidityE

Easy installationE

Easy connectionE

Easy maintenanceE

Ideal for commercial areasE

Page 102: GE Fire Kilsen

Special Temperature Detectors

Page : 100

ST802High Temperature Thermal Probe with relay output

The ST802 thermal probe high temperature heat detector is designedto protect from hazards where high temperatures are produced at aspecific point. The sensitive element (bulb) can be set at a distance ofup to 1 meter from the connection box. The ST802 provides a protentialfree relay output for alarm indication with COM, NC and NO contacts.

Specifications

Suppy Voltage 24 VDC

Current Consumption

Quiescent Ø

Alarm 100 mA

Alarm Monitoring 5A potential free relay

Capilliary pipe length 1 m

Probe Dimentions (l x Ø) 150 x 3 mm

Dimensions 140 x 100 x 70 mm

Colour Grey RAL7032

Working Temperature 50 °C to 300 °C

Weight 0.6 kg

Ordering Information

High Temperature Thermal Probe with relay outputST802

Completely metalE

Adjustable from 50 to 300 °CE

Back and side cable inputE

Sensitive probe with 1 m of stainless steel capillarypiping

E

Resistant to heat, grease and humidityE

Easy installationE

Easy connectionE

Easy maintenanceE

Potenial free alarm relay outputE

Page 103: GE Fire Kilsen

Door Magnets

Page : 101

CR255Electronic delay control for double-leaf fire doors

The CR255 is an electronic delay control unit for use with double-leaffire doors. It allows for the release of the one leaf of the fire door to beslightly delayed to allow for the two leafs to close properly and in thecorrect sequence.

Ordering Information

Electronic delay control for double-leaf fire doorsCR255

Easy to installE

May be installed inside the door release magnethousing

E

24 VDC operationE

Page 104: GE Fire Kilsen

Content

NKB602 Conventional fire alarm panel with 2 zones Page : 3

NKB604 Conventional fire alarm panel with 4 zones Page : 4

NKB606 Conventional fire alarm panel with 6 zones Page : 5

NK702 Conventional fire panel with 2 fire alarm zones Page : 6

NK704 Conventional fire panel with 4 fire alarm zones Page : 7

NK708 Conventional fire panel with 8 fire alarm zones Page : 8

NK712 Conventional fire panel with 12 fire alarm zones Page : 9

NK716 Conventional fire panel with 16 fire alarm zones Page : 10

NK703 Conventional extinguishing control panel with 3 zones Page : 11

NK706 Conventional extinguishing control panel with 6 zones Page : 12

RB404 Relay module, 4 potential free relays for NK700/Fx400 fire panels Page : 13

SB404 Relay module, 4 supervised relays for NK700/Fx400 fire panels Page : 14

EOL-ACT Active end-of-line device for use with FP400/KL700 fire panels Page : 15

KLBlack-S Black front panel cover (small footprint) Page : 16

KLBlack-B Black front panel cover (large footprint) Page : 16

KSA701-1 Analogue addressable fire detection panel - 1 loop Page : 17

KSA701-2 Analogue addressable fire detection panel - 2 loops Page : 18

NC785 RS485 expansion kit for KSA701/FP1500 fire panels Page : 19

KSA701R KSA701 Series LCD Repeater (mains powered) Page : 20

KSA701R-24 KSA701 Series LCD Repeater (24VDC powered) Page : 21

KSA705 Analogue addressable fire panel (expandable to 5 loops) Page : 22

KSA705P Analogue addressable fire panel with printer (expandable to 5 loops) Page : 23

KAL701 Loop driver module for KSA702/705 control panels Page : 24

KAL732 RS232 communications module for KSA702/5 control panels Page : 24

KAL785 RS485 communications module for KSA702/5 control panels Page : 25

KAL791 Protocol Converter RS232/485 - Kilsen / Johnsson Control Page : 25

KSA1204 Analogue fire panel, 2 loops upgradable to 4, 64 display zones Page : 26

KSA1208 Addressable fire panel, 2-8 loops, 64-255 display zones upgradable Page : 27

KSA1264R Repeater / emulator with 64 zone indications Page : 28

KSA12255R Global zone repeater, 64 zones expandable up to 255 Page : 29

LC1502 2-loop extension board for 1200/2000 series fire panels Page : 30

LON2000 LON700 driver for FP1200 / FP2000 Page : 30

LON2000R LON driver for FP1200/2000 - closed loop systems Page : 31

NC2011 ARCNET RS485 network card with single RS485 interface Page : 31

NC2051 ARCNET network card with single optical interface board Page : 32

NE2011 RS485 network extension board Page : 32

NE2051 Fibre optic network extension board Page : 33

PR2000 Internal printer Page : 33

RB2016 Relay extension board for 1200/2000 series fire panels Page : 34

ZE2064 64-zone LED extension fire and fault LED Page : 34

FRL700 LCD repeater Page : 35

NA704 LON700 network amplifier (4 way) Page : 36

NC700 LON700 interface board Page : 36

NC771 LON700 closed loop communication board (no driver) Page : 37

Page 105: GE Fire Kilsen

NE771 LON700 driver for the NC771 and NA704 Page : 37

OCB724 LON700 output board with 24 open collector outputs Page : 38

PS700 Plug-in power supply 3.5 A Page : 38

RB708 LON700 output board with 8 relays Page : 39

SIB716 Supervised input board 16 way LON700 Page : 39

SOB708 LON700 output board with 8 supervised outputs Page : 40

ZI708 8 zone input extension board Page : 40

KM260/1R3-03 CO detection control panel - 1 Zone (English Version) Page : 41

KM260/3R3-03 CO detection control panel - 3 Zones (English Version) Page : 42

KM260EXT3-03 CO detection expansion module (English Version) Page : 43

KM260C Blanking plate for KM260 panels Page : 44

KM170 CO detector with base and mounting supplement Page : 45

KZ400 Detector base for KL400/KM170 series devices Page : 46

S300 Surface mount supplement for KL300/KM170 detectors Page : 46

ASD20C Aspiration Smoke Detector Page : 47

ASD20F Filter housing for ASD20 Page : 48

ASD20FIL Filter only for ASD20 Page : 48

KV210 Rate-of-Rise Heat Detector Page : 49

KV210P Rate-of-Rise Heat Detectors with remote indicator output Page : 50

KL500 Low Profile Ionisation Smoke Detector Page : 51

KZ500 Fire detector base for KL500 detectors Page : 52

KL700 Ionisation detector, conventional Page : 53

KL710 Temperature detector (fixed and rate-of-rise), conventional Page : 54

KL731 Optical detector, conventional (with field exchangeable optical block) Page : 55

KL731B Optical detector, conventional - Black Page : 56

KCT731 Calibration Tool for KL731/DP331I Fire Detectors Page : 57

KL700A Analogue addressable ionisation sensor Page : 58

KL710A Analogue addressable temperature sensor Page : 59

KL731A Analogue addressable optical sensor (with field exchangeable chamber) Page : 60

KL731AB Analogue addressable optical detector - Black Page : 61

KL735A Analogue addressable dual (optical and thermal) sensor Page : 62

PG700 Fire sensor programmer Page : 63

KOB700 Replacement Optical Chamber for KL731/A & DP331I/1561 detectors Page : 64

KL7A Dust Protector Cover for KL700/A and Dx300/1500 detectors Page : 64

KZ700 Universal fire detector base Page : 65

KZ700B Universal fire detector base (for KL700/A and Dx300/1500) - Black Page : 66

KZ705 Universal fire detector base with earth connection Page : 67

S700 Surface mount accessory for KZ700 and KZ705 series bases Page : 67

KZ705I Analogue fire detector base with isolator Page : 68

KZ705AS Analogue fire detector base with sounder Page : 69

KZ705IAS Analogue fire detector base with isolator and sounder Page : 70

KZ705D Conventional fire detector base with diode Page : 71

KZ705R Conventional 12 VDC fire detector base with relay Page : 71

PA25/3L Low current remote LED indicator Page : 72

Page 106: GE Fire Kilsen

KAL410 Conventional Zone Monitor Unit - 1 Zone Page : 73

KAL414C Conventional Zone Monitor Unit - 4 Zones Page : 74

KAL426C Extinguishing Control Module Page : 75

KAL430 Relay Module - 1 Relay Page : 76

KAL434C Addressable Relay Module - 4 Relays Page : 77

KAL440 Supervised Relay Module Page : 78

KAL450 Addressable Manual Call Point Page : 79

DM715 EN54 universal glass for manual call point Page : 80

DM782 Hinged transparent MCP protection cover Page : 80

DM787 Surface mounting box with connectors, red Page : 81

KAL460 Digital Input Module Page : 82

KAL470 Isolator Module Page : 83

KAL490 Retention Module - 1 Input / 1 Output Page : 84

SK07A Addressable loop powered siren Page : 85

KR24B Illuminated warning sign (No text) 24VDC Page : 86

KR24-ING Illuminated extinguishing waring sign (English version) 24VDC Page : 87

SK07 Low consumption multi-tone alarm siren Page : 88

PCC-Config KSA701/FP1500 Configuration software kit Page : 89

PCG-Graphic102 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops) Page : 90

PCG-Graphic105 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-5 loops) Page : 91

PCG-GraphicNW Graphic Software for KSA700/FP1500 Fire Systems (multi-panel) Page : 92

KSP700 KSA702/5 Configuration software kit Page : 93

KSP701 PC Configuration RS232 Cable for KSA701/FP1500 fire panels Page : 94

PCC2000 Programming and configuration software Page : 95

PCG-N Graphics package network application with copy protection key Page : 96

PCG-S Graphics package with copy protection key Page : 97

PCM2000 Maintenance and support software with copy protection key Page : 98

ST801 High Temperature Thermal Probe with 2 wire connection Page : 99

ST802 High Temperature Thermal Probe with relay output Page : 100

CR255 Electronic delay control for double-leaf fire doors Page : 101

Page 107: GE Fire Kilsen
Page 108: GE Fire Kilsen

www.gesecurity.netAs a company of innovation, GE Security reserves the right to change product specifications without notice. For the latest productspecifications, visit GE Security online or contact your GE Security sales representative.

IPSCAT-2005-12-6 16:09:40