View
220
Download
1
Category
Preview:
Citation preview
FD 1311 SSMmax. power 13 kVA
Engine• Automatic excess fuel device.
• Self venting fuel system.
• Crankcase of high tensile light alloy.
• Environmentally friendly by using internal crankcase breathing system.
• Easy access for maintenance to feeding system, lubrication oil filter, fuel
filter and air filter.
• Safety stop in case of low oil pressure and high engine temperature.
• Suitable for crank start.
• Soundproof material, self-extinguishing (class 1).
Soundproof canopyThe GFD manual starting control panel has been designed and built to combineall the control instruments and warning both for engine and alternator.Steel panels are powder painted and proofed against rain and externalenvironment agents.
Main equipments included on the control panel are the following:
• Circuit breaker; • Earth fault device; • Hourmeter; •Voltmeter; •Ammeter;
• Electronic device for automatic shutdown of the engine in case of high
engine temperature and low oil pressure;
• Emergency stop pushbutton; • Starting key;
Standard version:
• n°1 Socket 16A 400V 3P+N+G;
• n°1 Socket 16A 230V 2P+G;
Version with 400V/230V switch:
• n°1 Socket 16A 400V 3P+N+G;
• n°1 Socket 16A 230V 2P+G;
• n°1 Socket 32A 230V 2P+G;
Generator
• Synchronous, 2 poles, self-excited, with compound
• Rotor and stator epoxy resin coated against external agents.
• Rotor dynamically balanced.
Standard versiona.c. output 400 V max.kVA
on three-phase socket 50 Hz cont.kVA
power factor cos ø
a.c. output 230 V max.kVA
on single-phase socket 50 Hz cont.kVA
power factor cos ø
Version with 400V / 230V switch
a.c. output 400 V max.kVA
on three-phase socket 50 Hz cont.kVA
power factor cos ø
a.c. output 230 V max.kVA
on single-phase socket 50 Hz cont.kVA
power factor cos ø
fuel
starting
alternator
engine
cooling system
displacement c.c.
n° cylinders
prime power HP
R.P.M.
fuel tank capacity lt.
¾ load operating hours h
sound power level LwA
acoustic pressure at 1 mt. dB(A)
9
13
11
0,8
Air
708
1
Diesel
Electric + Manual
FARYMANN 43F
78
15
3000
20
92
4,3
3,7
1
Synchronous
13
11
0,8
8,7
7,3
1
L 1280 mmW 720 mm
H roof 713 mmH hook 768 mm
320 kg
DIMENSIONS
MASS
CONTROL PANELA
.A. r
ev.0
04-
02-2
013
This drawing is only a reference and is not indicated for the installation. For more information, you may
contact your local dealer or Greaves Farymann . Greaves Farymann reserves the right to change
the design or specifications without notice and without any obligations or liability whatsoever For more
information, you may contact your local Greaves Farymann dealer.
Dealer:
Å Emergency stop buttonÅ Start/stop keyÅ VoltmeterÅ AmmeterÅ HourmeterÅ Phase selector switch (for
ammeter)
Green lamps:Å Control ON (when key is ON)Å Genset ON (when genset is
running)Å Load ON (when general breaker
switch is ON)Å Charger ON
Red alarm lamps:Å High engine temperatureÅ Low oil pressure
Å Electric circuit breakerprotection
Å General switchÅ DC breakerÅ Earth connection
Three-phase standard control panel
Å No. 1 EEC socket 16 Amps 3P+N+G 400VÅ No. 1 EEC socket 16 Amps 2P+G 230V
Å Emergency stop buttonÅ Start/stop keyÅ VoltmeterÅ AmmeterÅ HourmeterÅ Phase selector switch (for
ammeter)Å 400V/230V switch
Green lamps:Å Control ON (when key is ON)Å Genset ON (when genset is
running)Å Load ON (when general breaker
switch is ON)Å Charger ON
Red alarm lamps:Å High engine temperatureÅ Low oil pressure
Å Electric circuit breakerprotection
Å General switchÅ DC breakerÅ Earth connection
Three-phase control panel + 400V / 230V switch
Å No. 1 EEC socket 32 Amps 2P+G 230VÅ No. 1 EEC socket 16 Amps 3P+N+G 400VÅ No. 1 EEC socket 16 Amps 2P+G 230V
Greaves Cotton LimitedInternational Business
Industry Manor, Appasaheb Marathe RoadMumbai 400 025 INDIA
Phone : +91 22 2439 7575Fax : +91 22 2437 9555
info@greavescotton.com
www.greavescotton.com
Greaves Farymann Diesel GmbHIndustriestrasse 19
Lampertheim 68623 GERMANYFon: +49 6206 507 0
Fax: +49 6206 507 111info@farymann.dewww.farymann.de
FD 1311 SSM
Recommended