lPart No: AE-MAN-DEPTH Doc V: 1.0Digital Depth Gauges

•Beforeusingthedepthgaugeforthefirsttime,wipewithacleanclothideallysoakedwithcleaningoil.•Thedepthgaugeisaprecisionmeasuringinstrument.Avoidusingexcessiveforce,andtreatwithcare.•Thefittedbatteryisintendedforthefactorytestprocedureandthereforemaynotmeetthespecifiedbatterylife.•Avoidexposuretoallliquids,excessivehumidityortemperature.•Avoidexposuretobrightsunlight.•Neverapplyvoltageonanypartofthisdepthgaugeorelectricengrave.•Removethebatteryifthegaugeisnotbeingusedforalongperiodoftime.•Neverusesolventstoclean.Onlyuseasoftclothwithcleaningoil.

Precautions

Digital Depth Gauge

Standard Depth GaugeDepth Measurement

Depth

1 3

4

8

5

7 610

9

2

1

2 3

4 5 6

7

8

1. Frame. 2. Anvil. 3. Spindle. 4. LCD Display.5. Thimble. 6.Ratchet. 7. SPC Output.8. Function Buttons.

1

2

3

4

5

7

8

9

10

1. Probe Extension. 2. Function Buttons. 3. LCD Display.4. Slider. 5. Battery Cover. 6. Locking Screw.7. Guiding Face. 8. Beam. 9. Instrument Base.10. Instrument Base Reference Plane.

6

Battery Replacement

1. Slide open the battery cover.

8. Insert the two lugs on the cover.9. Gently lower battery cover.

2. Lift battery cover front edge.3. Remove cover.

4. Remove battery (a magnet tip tool can be used).5. Locate side spring contact.

6. Insert replacement battery edge against side contact. 7. Press down on other edge.

1 2

3

4

5

6

7

8

9

10

11 12

1 2

3

4

5

6

7

8

9

10

11 12

1 2

3

4

5

6

7

8

9

10

11 12

1 2

3

4

5

6

7

8

9

10

11 12

1 2

3

4

5

6

7

8

9

10

11 12

10. Pull battery cover outward sightly11. Fully lower cover

1 2

3

4

5

6

7

8

9

10

11 12

12. Slide battery cover fully closed.

1 2

3

4

5

6

7

8

9

10

11 12

Magnet tipped

tool

Positive (+) side up

8

6

2 4 3

5

7

1

9

1. Base. 2. Reading Head.3.LockingScrew.4.LCDdisplay.5. Data Port.

8

6

2 4 3

5

7

1

9

Depth gauge with hook 6.Beam.7.BatteryCover.8.FunctionButtons.9.Hook.

Depth Gauge with Hook Depth Measurement

(add hook thickness to display value)

Depth Gauge with Hook Thickness Measurement

Depth Gauge with Hook Step Measurement

(add hook thickness to display value)

© Allendale Group

© Allendale Group

© Allendale Group

© Allendale Group

© Allendale Group

© Allendale Group

© Allendale Group

© Allendale Group

© Allendale Group

© Allendale Group

© Allendale Group

© Allendale Group

mac

hine

-dro

.co.

uk

www.machine-dro.co.uk - Allendale Electronics Ltd, Pindar Road, Hoddesdon, Hertfordshire. EN11 0BZ.Images & Content ©2010 Allendale Electronics Limited. E&OE - Specifi cations subject to change without prior notice.

Dig

ital

Dep

th G

auge

Use

r M

anua

lTrouble Shooting

Metric/Inch conversion

25.40mm

mm/inch

Pressmm/inchtoconvertfrommetrictoinchdisplay.

1.000

Thedisplaywillindicatewhichunitsarebeingdisplayed.

mm/inch

in

Problem PossibleCause SolutionFlashingdisplay Lowvoltage

PoorcontactReplace batteryClean contact

Nodisplay DeadorweakbatteryPoorcontact

Replace batteryClean contact

Nochangetodisplay Internalerror"H"shownondisplay

Remove battery for 1 hourRemove battery for 5 minutes

Can't zero HoldfunctionactiveTolerancefunctionactive

Switch off function Switch off function

Erraticorfrozendisplay Contaminationbetweenbeam&headlowvoltage

Wipe cleanReplace battery

Erroneous reading LowvoltageContaminationbetweenbeam&headLowambienttemperature

Replace battery Wipe cleanStore at normal room temperature

Calibrating Standard Depth Gauge

Calibrating Depth Gauge with hook

1. Ensure the locking screw is loose.2. Wipe clean surface plate or similar flat service.3. Ensure gauge base is clean.4. Place gauge base on surface plate.5. Slide the beam downwards so measuring contact is in contact with the surface plate.6. Press zero button.

1. Ensure the locking screw is loose.2. Ensure gauge base and hook is clean.3. Close the gauge.4. Press zero button.