ISD-MASP-S04022Copyright © Yokogawa Electric Corporation2004/12/08
Yokogawa Electric Corporation
CENTUM CS 3000 R3Presentation (V net version)
April 20, 2023
CENTUM CS 3000 R3Page 2
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Contents
What’s CENTUM CS 3000 R3?System ConfigurationThe most Reliable and Economical SolutionOperation and MonitoringEngineering EnvironmentSolution-based SoftwareMigration
CENTUM CS 3000 R3Page 3
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
What’s CENTUM CS 3000 R3?
CENTUM CS 3000 R3Page 4
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
CENTUM CS 3000 R3 System Concepts
CENTUM CS 3000 R3 is Yokogawa’s flagship control system platform. Its open interfaces facilitate data access from business domains.CS 3000 is a scalable, flexible system designed to work with your existing systems and grow with your business, reducing total cost of ownership (TCO).CS 3000 is a key part of Yokogawa’s solutions and features:– Open environment for optimizing the whole production– Optimal operating environment– Hardware upgradeable to the latest technology– Durable system that can be optimized your plant– Minimizes total cost of ownership– Increases profit– Powerful engineering functions
CENTUM CS 3000 R3Page 5
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
CENTUM Series (DCS) Evolution
1st CENTUM1st CENTUM
2nd CENTUM 2nd CENTUM
CENTUM VCENTUM V
CENTUM-XLCENTUM-XL
CENTUM CSCENTUM CS
CENTUM CENTUM CS 3000CS 3000
19751975
19811981 19841984
1988198819931993
19981998
CENTUM has developed as a true open system.
WorlWorld’sd’s First DCS First DCS
CENTUM CS 3000 R3Page 6
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Yokogawa CENTUM at Work
ANGOLA(3)
TOTAL 16,188 PROJECTS
IRELAND(3)
BULGARIA (1)
BELARUS(3)
NORWAY(2)
GREECE (18)
POLAND (11)
FINLAND(1)
YUGOSLAVIA(1)
SWEDEN (1)
AZERBAIJAN (1)
DENMARK(5)
ROMANIA(5)
CROATIA(2)
HUNGARY (27)
KAZAKHSTAN(1)
SWITZERLAND(12)
AUSTRIA(29)
PORTUGAL(5)
EUROPEEUROPE
BELGIUM (119)
SPAIN(83)
UK(55)
50SLOVAKIA/CZECH(62)
50
NETHERLANDS (128)
100
RUSSIA(79)
50
UKRAINE(3)
100
FRANCE (176)
50100
GERMANY (175)
50100
ITALY(108)
10050
GHANA(2)
BOTSWANA(3)
GABON(2)
AFRICAAFRICA
SENEGAL(1) KENYA(1)
NIGERIA(23)
MOROCCO(13)
EGYPT(20)
SOUTH AFRICA(67)
5050
ALGERIA(16)
JORDAN (3)
KUWAIT (7)
OMAN (12)
U.A.E (17)
BAHRAIN (18)
MIDDLE EASTMIDDLE EAST
SAUDI ARABIA (91)
50
IRAN (52)
50
CANADA (5)
NORTH NORTH AMERICAAMERICA
USA (615)
500500 100
COLOMBIA (13)
ARGENTINE (8)
MEXICO (13)
COSTA RICA (1)
PERU (1) CUBA (1)
URUGUAY(1)
VENEZUELA(2)
SOUTHSOUTHAMERICAAMERICA
BRAZIL (266)
10010050
ASIA PACIFICASIA PACIFIC
PAPUA NEW GUINIA(1)
PHILIPPINES (58)
50
FIJI (6)
VIETNAM (10)
THAILAND (202)
100100AUSTRALIA (292)
1001005050
SINGAPORE (127)
100
INDONESIA (128)
100
MALAYSIA (153)50100
10,039
JAPAN
NORTH ASIANORTH ASIA
PAKISTAN (16)
MYANMAR (4)
TURKEY (27)INDIA (572)
500500 50
KOREA (534)
500500
TAIWAN (272)
100 50100
CHINA (1125)
1001,000
As of March 2004
CENTUM CS 3000 R3Page 7
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
System Configuration
CENTUM CS 3000 R3Page 8
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
CS 3000 System Configuration - OverviewCS 3000 System Configuration - Overview
Control NetworkControl Network
Information NetworkInformation Network
ooo
PROFIBUS-DPV1PROFIBUS-DPV1FOUNDATIONFOUNDATION Fieldbus Fieldbus HARTHART
ExaqunatumExaqunatum
PRMPRM ExaopcExaopc
ModbusModbusDeviceNetDeviceNetControlLogiControlLogixx
Manufacturing Execution SystemManufacturing Execution System
Control StationControl Station
HMIHMI
Field NetworkField Network
CENTUM CS 3000 R3Page 9
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Operation Room
Using the latest technology, Yokogawa provides smart control rooms.
CENTUM CS 3000 R3Page 10
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Control Network (V net) Technology (1)
CENTUM capabilities for large-scale applications:– 64 stations per domain with full redundant configuration.
– Up to 1,000,000 tags per system.– 1 sec. data refresh for five screens (simultaneous display) with
400 data per display.
CENTUM performance examples:– An international major oil company conducted performance
tests at Yokogawa HQ and confirmed CENTUM’s superior performance.
– CENTUM continues to be selected for long-term and large-scale projects.e.g. NAM-GLT, CSPC Nanhai, etc.
CENTUM CS 3000 R3Page 11
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Control Network (V net) Technology (2)
FCS
I/O
ENG HIS
20 operator screens20 field control stations (FCS)160 AI, 160 AO, 320 DI, 320 DO per FCSSystem total: 3,200 AI, 3,200 AO, 6,400 DI and 6,400 DO
CENTUM CS 3000 R3Page 12
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
CENTUM Reliability
CENTUM CS 3000 R3Page 13
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
CENTUM Reliability Data
CENTUM-XL Availability0.999 999 897 ; Aug. 1988 to Nov. 2001(Six nines)
CENTUM CS/CS 3000 Availability0.999 999 973 ; Jun. 1993 to Nov. 2002(Seven nines)
CENTUM-V AvailabilityDuplexed-CPU FCS’s total runtime, Apr. ’82 to July ’98609,330,270 hrs (approx. 70,000 years)(Note) Definition of “system failure” -- Simultaneous failure of two or more loops
CENTUM CS 3000 R3Page 14
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
FCS Redundancy -Pair&Spare CPU-
Both CPU modules are processing independently, so CENTUM achieves real bumpless switchover. Moreover ...A pair of CPU chips
on each module.– Each CPU is processing in
dependently.
Result checking– Processed results of
CPUs are every time compared each other.
– If the results are not congruous, control switches to the stand-by module.(To avoid the effect of transient error)
V net I/F
CPU 1
CPU 2
PIO I/F
V net I/F
Power card Power card
Coupler Coupler
V netV net
I/O bus
Compa-
rator
PIO I/F
PIO I/F
PIO I/F
IO bus I/F
CPU module CPU module
Coupler Coupler
Mainmemory
with ECC
Compa-
rator
CPU 1
CPU 2
Mainmemory
with ECC
IO bus I/F
CENTUM CS 3000 R3Page 15
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Full Redundancy of Node Unit
IO IO IO IO IO IO
PW PWCPU CPU
24 V
5 V
V netCPL
V netCPL
V net
ESB-M
ESB-M
ESB-BUS
SB-BUS
All components in a rack are redundant.The dual-redundant backplane bus (SB-BUS) is unique!Every type of I/O module can be redundant.
CENTUM CS 3000 R3Page 16
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Economical Solution
CENTUM CS 3000 R3Page 17
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
CENTUM CS is most economical solution
CENTUM CS 3000 R3Page 18
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Field Control Station
CENTUM CS 3000 R3Page 19
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Field Control Station (FCS)
FCS provides full scalability from a single node system to a super large DCS solution in the single architectureFull application compatibility between Compact FCS and Standard FCS
Compact Compact FCSFCS
Standard Standard FCSFCS
CENTUM CS 3000 R3Page 20
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
System Scalability
CS 3000 can cover from small scale to 1-million tag super large DCS systemCS 3000 has full scalability by single architecture
Control intelligence can be distributed to each process unit to fit the application
CCR Unit #1 Unit #2
CENTUM CS 3000 R3Page 21
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
FIO Module Design Concept
Highest ReliabilityHighest Reliability– All FIO modules can be configured redundantFlexibleFlexible– Flexible installation and configuration– Flexible choice of field wiring OpenOpen– Connects various fieldbuses– Remote I/O bus based on EthernetCompactCompact– High-density installationHigh PerformanceHigh Performance– Internal bus and remote I/O bus
CENTUM CS 3000 R3Page 22
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Control Functions
By combining the CS 3000 R3’s powerful functions, such as various control blocks, system integration, advanced unit instruments, and batch control, an optimum control system that meets your plant’s needs can be configured efficiently.For batch control– Only the CS Batch 3000 provides powerful
and flexible batch control. CS Batch 3000 is an ISA-88 (IEC61512) based batch control software.
CENTUM CS 3000 R3Page 23
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Various Communication Protocols
Foundation fieldbusHARTProfibus DPV1Modbus RTU/ TCPDevice NetControl LogixOther proprietary popular protocols– AB, Siemens, Mitsubishi, and so on
CENTUM CS 3000 R3Page 24
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Operation and Monitoring
CENTUM CS 3000 R3Page 25
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Operation Window
Secondary windows
System message window
Primary window
Tool box
CENTUM CS 3000 R3Page 26
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Trend Window
Real time trendingHistorical trending
Long-term trend data storage
Supports:- Batch trending (start/stop)- Rotary trending- Reference trending
CSV file export
CENTUM CS 3000 R3Page 27
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
CENTUM Window List
Standard operation windows– Overview Window– Control Window– Trend Window– Tuning Window– Graphic Window– Faceplate Window
System maintenance windows– System Status
Overview Window– Station Status Window– HIS Setup Window– Logic Chart Window
Message windows– System Alarm Window– Process Alarm
Window– Operation Guidance
Window– Process Report
Window– Historical Message
WindowStatus monitoring windows– Control Drawing
Window– Sequence Table
Window– SFC Window– Logic Chart Window
CENTUM CS 3000 R3Page 28
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Security Functionality
Security function in CS 3000 enables the definition of the following attributes:Access criteria– Determines how / who / when / what information can be
accessed.– Enables setting by:
• plant hierarchy• window
Grouping criteria– Enables grouping functionality for:
HIS– operation personnel– alarm handling
Authentication– Enables registration of users with the following
parameters:• user ID• password• accountability (authority)
FDA Regulation– CS 3000 meets the 21CFR Part11
CENTUM CS 3000 R3Page 29
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Remote Monitoring and Operation
CENTUM CS 3000 R3Page 30
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
HIS Terminal Service (HIS-TS)
HIS TSHIS TS
Office Office LANLAN
HISHIS
- Faceplate operation- Trend view- Alarm monitoring- Other graphic windows
- Faceplate operation- Trend view- Alarm monitoring- Other graphic windows
FCSFCS
V netV net
EthernetEthernet
FirewallFirewall
Note that the HIS TS functions as an HIS with the same capacity as regular HISs.
CENTUM CS 3000 R3Page 31
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Web Monitoring
Ethernet
FCSFCS
V net
Dial-up Internet Connection
Plant monitoring on a business trip, at home, at maintenance office, etc. using Web Browser
HISHIS
Graphic windowstrend windows, ITV windows
Web ServerWeb Server
HIS graphic/trend windows are converted into HTML files and Java Applets
CENTUM CS 3000 R3Page 32
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Wide Area Connection
DSU (Digital Service Unit)
DSU
DSU
DSU
DSU
Public Communication
Ethernet
V net
Onshore Offshore
Center DomainCenter Domain Local DomainLocal Domain
HISHIS
FCSFCS
CGWCGW CGWCGW
FCSFCS
HISHIS
Two systems can be connected by Wide Area CGW.
Ethernet
V net
Ethernet
V net
CENTUM CS 3000 R3Page 33
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Engineering
CENTUM CS 3000 R3Page 34
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Engineering Features
Platform: Generic PCConcurrent Engineering– Uses multiple machines for parallel engineering
It is able to exchange data with general Windows applicationsVirtual Test Functions– Multiple-FCS simulation is possible on a PC– FCSs can communicate with each other
CENTUM CS 3000 R3Page 35
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Concurrent Engineering
Engineering can be done by multiple PCs simultaneouslyContributes to reducing engineering time
Master Database
DOWNLOAD the project
Engineering PC
Engineering PC
Engineering PC
Backup
HISHIS
FCSFCS
CENTUM CS 3000 R3Page 36
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Engineering
Simple data exchange– Data can be processed on typical Windows
application software such as MS Excel using Windows data-exchange function. Not only the cut and paste function, but also the file import and export can be performed. Also generated project data can be reused in other stations or projects by using these functions.
Online maintenance– Control functions can be modified without
stopping the entire FCS and without affecting non-changed control functions. Using online maintenance, the plant can be run with minimum disturbance.
CENTUM CS 3000 R3Page 37
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Integration with InTools
Source DocumentsP&ID
ControlNarratives,etc.
INtools RDB
Instrument Index
Module
Project data
Configuration information
import
(1) Product Information Update
(2) Direct Data Exchange
YOKOGAWA Web
(1) Product Information Updating by INtools Users- Download of the latest FF field device information- Download of the latest CS 3000 information (I/O, TB, cables)
(2) Direct Data Exchange between InTools & CS 3000- Initial generation- Data transfer (INtools --> CS3000)- Data transfer (INtools <-- CS3000)
CS3000 ENG
I/O
Field Device (FF)
CENTUM CS 3000 R3Page 38
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Advanced Debugging
Full-scale system test can be performed without target hardware.Full-scale system test can be performed without target hardware.
ConfigurationData
Loading HIS configuration
Loadingcontrol function
Real Plant
Real Plant
FCSFCS
HISHIS
Input
Output
ConfigurationData
Loading HIS configuration
Loadingcontrol function
Virtual Plant
Virtual Test
HISHIS
Input
Output
FCS SimulatorFCS Simulator
Auto WiringAuto Wiring
In PC (HIS) MemoryIn PC (HIS) Memory
CENTUM CS 3000 R3Page 39
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Smart Electric Documents (IM)
Electronic documents come standard Operator can browse the IM during operation Online help and pinpoint help viewer
YOKOGAWACS 3000
HIS Opera
tion
YOKOGAWACS 3000
HIS Opera
tion
YOKOGAWACS 3000
HIS Opera
tion
CENTUM CS 3000 R3Page 40
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Pinpoint Help Viewer - StoryVIEW -
Same look&feel as Internet Explorer– Back/Forward, Favorite, Bookmark
Smart search functionKeyword
•You can search the pinpoint description by keyword from all instruction manuals or a manual you selected.
•You can search from 2 viewpoints.
•Search by function•Search how to configure
CENTUM CS 3000 R3Page 41
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Solution-based Software
CENTUM CS 3000 R3Page 42
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Package Lineup
Exa series is value-added solutions for process control systemsExa realizes safer and more effective operationExa is implemented based on the DMAIC (Define, Measure, Analyze, Improve, Control) steps of Six SigmaExa supports continuous improvement
Process Control System
OPC Interface Package
Plant InformationManagement System
AAA AAA SuiteSuiteShell Multivariable
Optimizing Controller
Robust Quality Estimator
Control ApplicationsStandards
Event Analysis Package
Operation EfficiencyImprovement Package
Automated AlarmManagement System
APC *1 PIMS *2 AOA *3
Batch Plant InformationManagement System
*1:APC=Advanced Process Control, *2:PIMS=Plant Information Management System, *3AOA=Advanced Operation Assistance
CENTUM CS 3000 R3Page 43
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Migration
CENTUM CS 3000 R3Page 44
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Yokogawa’s Long-term Commitments
Latest technology with Yokogawa vigilance inside
– The world’s-first DCS? system based on Windows XP.
– Windows 2000 is also supported.– The latest CS 3000 R3 components can coexist with
existing R2 systems.
Long-term support for legacy components– Spare stock and re-design for functionally
compatible alternatives.
Clear evolution path– Step-by-step H/W migration and S/W conversion are
available for CENTUM V and CENTUM-XL, and CENTUM CS can coexist with CENTUM CS 3000.
– You can leverage new capabilities at each step.– You can keep the existing field wiring.
CENTUM CS 3000 R3Page 45
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Yokogawa CENTUM Evolution Path
BCV
BCVCOPS2COPS2
CENTUM VCENTUM V
CFFSCFFSCFCS2CFCS2
COPSVCOPSV
CFCD2CFCD2
CENTUM-XLCENTUM-XL
EOPSEOPS
CFCSCFCS EFCDEFCD
ENGSENGS
CENTUM CS 3000 R3CENTUM CS 3000 R3
HISHIS
FFCSFFCS
KFCSKFCS
HF-BusHF-Bus
1-MBPSDual Redundant
Token Pass
1-MBPSDual Redundant
Token Pass
CENTUMCENTUM
CFCDCFCDCFCSCFCS
COPSCOPSF-BusF-Bus
250-KBPSDual Redundant
Token Pass
250-KBPSDual Redundant
Token Pass
V netV net
10-MBPSDual Redundant
Token Pass
10-MBPSDual Redundant
Token Pass
CENTUM CSCENTUM CS
ICSICS
EWSEWS PICSPICS
FCSFCS
CENTUM CS 3000 R3Page 46
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Yokogawa’s Migration Solutions
Existing CENTUM-XLExisting CENTUM V
Existing CENTUM CS
CENTUM CS 3000 R3Page 47
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Existing CENTUM-XLExisting CENTUM V
Existing CENTUM CS
Plant Information Management System
V net
Ethernet
PIMSPlant Resource
ManagerUpper level clients
PRM
HIS
Step 1 R3 HIS is added to existing systems.
•The latest operation technologies
•Seamless connection
with business domains
Yokogawa’s Migration Solutions Step 1
CENTUM CS 3000 R3Page 48
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Existing CENTUM-XLExisting CENTUM V
Existing CENTUM CS
Plant Information Management System
V net
Ethernet
PIMSPlant Resource
ManagerUpper level clients
PRM
HIS
R3 FCSR3 FCS + Existing I/O modules
Step 2 Upgrading FCS CPU to R3
•New control functions•Large capacity
Yokogawa’s Migration Solutions Step 2
CENTUM CS 3000 R3Page 49
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Existing CENTUM-XLExisting CENTUM V
Existing CENTUM CS
Plant Information Management System
V net
Ethernet
PIMSPlant Resource
ManagerUpper level clients
PRM
HIS
R3 FCS
R3 FCS + Existing I/O modulesR3 FCS
Step 3 (XL, V only) Upgrading I/O modules to R3
•Migration to R3 is completed without changing field wiring!
Yokogawa’s Migration Solutions Step 3
CENTUM CS 3000 R3Page 50
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Yokogawa Commitment
QualityQuality– Absolute performance guaranteed.
InnovationInnovation– Total solutions guaranteed.
ForesightForesight– Continuous evolution guaranteed.
CENTUM CS 3000 R3Page 51
ISD-MASP-S04022 Rev. 3 R3.06 SR, Solution marketingCopyright © Yokogawa Electric CorporationJan-April, 2005
Let us be vigilant about your business!
Recommended