6

AIR SYSTEM INLET VALVE

Spring loaded in the ready position

Control Air closes the inlet

Also serves as check valve

No-Load Condition Load Condition

Unload Condition Blow- Down Condition

9

REGULATING VALVE

Spring loaded

Adjusting receiver pressureby changing spring tension

• to pressure gauge and loading valve

• to speed regulator• to unloading valve

Regulating pressure:

Receiver pressure

The air receiver pressure can be set to another value by adjusting the spring tension of the regulating valve. This is done by turning the handle on top the valve. Increasing the spring tension, by turning in, will increase the regulating pressure and consequently the pressure inside the vessel. Turning out will decrease the pressure.

In order to regulate the pressure inside the reciever tank of our compressor, the air intake and the engine speed have to be controlled. This is done pneumatically. For that reason, we need regulating pressure. The regulating valve reduces the pressure inside the tank, thus providing the regulating pressure. This regulating pressure is then supplied to the unloader valve and the speed regulator or RPS.

10

Maintains a minimum pressure

of 58 PSI for oil flow

Also contains the final check

valve

AIR SYSTEM MINIMUM PRESSURE VALVE

Control Panel

12

XC 2002 Controller

13

XC2002 Controller Overview

14

XC 2002 Control Module

15

XC 2002 - Menus

On newer units Parameters are under Extra Views.

*Password is 2003*

XC 2002 Controller – 1.200 Program

XC 2002 Controller – 1.200 Program

Service Timer 1 = 500hrs

Service Timer 2 = 1000hrs

“On” lets you connect to engine with machine not running

Automatically unloads unit “unit will not reload”

Automatically loads “with use of in line micro switch”

XC 2002 Controller – 1.200 Program

XC 2002 Controller – 1.200 Program

XC 2002 Controller – 1.200 Program

XC 2002 Controller – 1.200 Program – Unit Type 2

Event Logging

J1939 Canbus Engine Communication

XC2002 Service Timer Reset

24

Scroll through the controller menu to “Parameters” (on some units “Parameters” may be a submenu under “Extra Views”)

Press Enter to select Parameters

Scroll to ST1 Reset or ST2 Reset as needed (ST1 = 500 hours, ST2 = 1000 hours)

Press Enter to select to reset the appropriate timer

Center option will highlight; scroll to highlight “Yes” and press Enter

Change Password to 2003 and press Enter

Service timer is reset

Engine Fault Code List

Engine Fault Code List

Engine Fault Code List

Engine Fault Code List

Engine Fault Code List

Engine Fault Code List

Engine Fault Code List

Engine Fault Code List

Engine Fault Code List

Displaying of J1939 DM1 Alarms

Wiring Schematic – XAS 375 JD6

Canbus terminator resistor p/n 1310030622

36

Legend

37

John Deere – Tier III – RPS in place of Pneumatic Speed Regulator

Regulating Pressure Sensor

“Speed Sensor”

38

Preheat Relay K1 Controlled by JDEC

Starter RelayPreheat Relay

39

Preventive Maintenance Filter Kits – XAS 375 JD6

Spare Parts Recommendation

41

Contact Numbers

•Main Number Atlas Copco Technical Support 1-800-732-6762 Option 3

•Clayton Jones - Hurricane Boosters/Compressors - Supervisor1-216-643-6802 direct & 1-317-681-4602 mobile

•Andrew Stevenson – Compressors: Low Pressure1-720-479-2486 direct & 1-404-751-6717 mobile

•Will Hudson – Generators/Compressors 1-800-732-6762 Ext. 12920 & 1-832-454-8123 mobile

•Andrew Calendar – Compressors: High Pressure1-720-479-2487 direct & 1-404-242-6203 mobile

•Jon Monaco - Hydraulic Att./Handheld Tools 1-800-732-6762 Ext. 12929 & 1-216-816-5008 mobile

•Brandon Dyer – Compressors: Low Pressure/Hydraulic Att.1-216-643-6807 direct & 1-216-219-2290 mobile

•Scott Ellinger – Compressors1-720-479-2476 direct & 1-720-375-1795 mobile

Committed tosustainable productivity.

Recommended