User’s ManualUnder Counter Extream
MADE IN KOREA
• The consumer accepts any and all responsibilityand/or liability if replacement filters and/or partsare not manufacturer specific.
• This product is subject to changes that enhanceits performance without prior notification.
How to Measure : Place 10-15 ml of test water in acontainer and add 2-3 drops of reagent. Then, mix welland check color of the water with the pH chart above.(Color is dependent on water quality and reagent)
pH Chart
http://www.tyentgroup.com
To Our Valued Customers Table of contents
UCE-9000 Turbo user’s manual
2 3
Table o
f co
ntent
s
To O
ur V
alue
d Cus
tomers
Thank you for purchasing the UCE-9000 Turbo Water Ionizer.
• We are not responsible for any accidents and/or malfunctions dueto the improper use of this machine.
• Please keep the manual and warranty card in a safe place, so thatit’s easily accessible when you need it.
• Please refer to this manual often when you have questions duringusage or when troubleshooting this unit.
Please read all safety warnings and this User’s Manual carefullybefore using this product to ensure proper product usage. (Keep themanual handy for easy reference.)
Intended Use
This device creates functional alkaline, ionized water. It changesthe properties of regular tap water through the use of electrolysis.Following are the changes normal tap water undergoes via this process:
• An increase or decrease in pH level
• Creation of negatively charged hydrogen ions (anti-oxidants)
• Smaller water molecule clusters for better absorption
• An increase in oxygen
• Purification through filtration
To Our Valued Customers
Before Usage
Safety Precautions and Warnings
Dispenser Overview
Unit Overview
Product Features
Package Contents
Parts Drawing for Installation
Under-Sink Installation
Dispenser Installatio
Ionizer Installation
Customer Serviceable Parts
How to Change the Filters
Operation Touch Screen
Unit Usage
System Setup Method
Voice On/Off Selection
Manual Cleaning Function
Eco Mode
Turbo Function
Recommendations for using this unit
Hot Water Sensor
Unit Specifications
Troubleshooting
2
4
5
10
11
12
16
17
18
19
21
23
24
26
30
32
36
37
38
39
40
42
43
44
Before Usage Safety Precautions and Warnings
UCE-9000 Turbo user’s manual
4 5
Befo
re U
sage
DANGER (Red Warning Sign)–indicates an imminent hazardthat could result in serious injuryor death. If you see this, stop theuse of this unit immediately.
WARNING (Orange Warning Sign)– indicates a potential hazard thatcould result in significant bodily harmor damage to the unit. If you see this,stop the use of this unit.
ATTENTION (Yellow Warning Sign)– indicates a potential hazard thatcould result in minor bodily harm ordamage to the unit.
Safety precautions are provided for the safe and proper use of this unit and canprevent danger, bodily harm and/or possible damage due to misuse. Please makesure you are familiar with all the safety precautions and warnings associated withthis unit.
PLEASE FOLLOW ALL INSTRUCTIONS WHEN YOU DRINK WATER CREATED BYELECTROLYSIS FROM THIS UNIT.
Do not drink functional water with medication.Use filtered Water instead.
Always consult your primary care physicianbefore drinking functional water. Only drinka small amount for the first week near aneutral pH level. This will give the body timeto adjust to functional water during thedetoxification period.
If you notice any negative effects from drinkingfunctional water, stop drinking immediatelyand consult with your primary care physicianabout changes in your body’s pH level.
If you are currently under the care of aprimary care physician for an existingcondition, consult with your primary carephysician about how changes in pH andother characteristics of functional watercould affect your condition.
If you suffer from gastric anacidity, kidneyfailure or potassium excretion, you shouldnot drink functional water.
Verify the pH levels of the functional water
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
dispensed from this unit on a monthly basis to ensure proper function. This can be donewith the supplied reagent drops and a pHcolor chart.
When switching from one pH to another,it is good practice to let the water run forseveral seconds before using.
It is common to drink half your body weightin ounces. For example, if you weigh 180pounds, it may be wise to drink 90 ouncesof water per day. This especially appliesafter you have given your body some timeto adjust to the new pH level.
9.5 to 9.8 pH is the recommended drinkinglevel for functional water. It is not recommended to drink functional water above 10 pH.
If you wish to store functional water, use aglass, stainless steel or other non-leachingmaterial and store in the refrigerator.
Never run hot water through this unit.
Never drink acidic water.
Do not use if the power cord is damaged orin a loose power outlet.
Do not pull the power cord. Never touch powercord or power outlet with wet hands.
Do not forcibly bend, squeeze, damage orcrush the power cord under heavy objects.
Unplug the power cord during general maintenance,repair, inspection and while replacing parts.
Do not use power surge protectors with this unit.Use unit with its own dedicated power source.
Only use the unit with the correct voltage.
Regarding Power Supply
(Hereinafter referred to as “functional water”)
Safe
ty P
recau
tio
ns a
nd W
arning
s
UCE-9000 Turbo user’s manual
6 7
Safe
ty P
recau
tio
ns a
nd W
arning
s
Safe
ty P
recau
tio
ns a
nd W
arning
s
Do not spray water on the main unit. Do notclean with a damp cloth, benzene or otherchemicals, which may leak into the unit.
Do not store unit near chemicals, food, metalsor medication.
Do not poke or scratch the touch pad or LCDdisplay with sharp objects.
It is beneficial for the maintenance of the machineto run a strong acidic level for a period of 5minute cycles twice weekly. This will help tomaintain a clean chamber.
To reduce the risk of electric shock, do notremove cover; no user-serviceable parts inside.Refer servicing to qualified service personnel.Removing the cover will void the warranty.
In case of strange noises, burning odor or smoke,unplug the power cord immediately and referservicing to qualified service personnel.
Do not place ANY objects on top of this unitregardless of how small.
Replace filters every 6 months to optimize thepurification performance of this unit even if thereplacement indicator light isn’t turned on.
In case water leaks out of the unit (other thanhoses) or unit is standing in a puddle of water,shut off the water supply, unplug the power cordand refer servicing to qualified service personnel.
Do not use alkaline or acidic water in fish bowlsor aquariums. The sudden change in pH couldbe harmful or fatal to some marine life.
Usage
benzene thinner
UCE-9000 Turbo user’s manual
8 9
Safe
ty P
recau
tio
ns a
nd W
arning
s
Safe
ty P
recau
tio
ns a
nd W
arning
s
Do not place this unit near heat sources.
Do not connect water line to a hot water supply.
Do not place this unit on an uneven surface.Do not drop or use excessive force on this unit.
Do not use unfit raw water in accordance to thestandards of the water service act.
Do not use in areas of high humidity and/or hightemperature.
Installation
In the case where the unit isn’t used over along period of time, shut off the valve and unplugthe power cord.
Storage
In case the original packaging is not available,cover the unit in plastic to avoid scratching thesurface.
Remove the filters and turn them upside downto remove excess water before storing.
Store unit in its original packaging in a cool, dryplace when not in use.
Carefully remove this unit from packaging. Keeporiginal packaging for future storage and unittransportation.
UCE-9000 Turbo user’s manual
10 11
Unit O
verv
iew
Disp
ens
er
Ove
rvie
w
Dispenser Overview Unit Overview
Front View Front ViewRear View Rear View
●
●
●
●
●
Jog Dial
Water Outlet Pipe
Drain Pipe
Fixing Nut
Speaker
1
2
3
Front CaseFront CoverFront Door Case
●
●
●
1
2
3
4
5
Hanging GrooveRear CaseProduct StickerPower SwichFusePower Cord
●●●●●●
123456
4
5
6
Bottom View
●
●
●
Alkaline OutletAcid OutletTap Water Inlet
1
2
3
●
●
4
5
5
MCU CablePower Code
29.5cm11.6inch
17.2cm6.8inch
3.3cm1.3inch
13.2cm5.2inch
11cm4.3inch
16cm6.3inch
39.3cm15.5inch
13.2cm5.2inch
36cm14.1 inch
38.2cm15inch
SINK
5cm2inch
UCE-9000 Turbo user’s manual
12 13
Pro
duct
Feat
ures
Pro
duct
Feat
ures
Product Features
Upgraded TURBO SYSTEM
Turbo upgrades to the SMPS Type Power Supply system produceboth the acid turbo water and strong alkali water you need!
SMPS Type Power Supply System
SMPS Type Power Supply System provides the maximuminstantaneous output needed to produce the highly stable electricpower required for each phase of electrolysis.
9 Electrodes with Round-Mesh Plate Technology
These 9 Platinum-Coated Titanium Plates are made with highlystable, durable mesh technology that enhances the instantaneouselectrolysis efficiency.
Light and Screen Indicators for Water Discharge Detection
Changes to the LCD screen and Jog Dial light can be easilyidentified to check each selected phase.
Excellent MP3 Sound Quality with Guided Support
Functions under operation can be further identified by the top-quality voice guided system.
Leading Environmentally Friendly Technology by ECO MODE
True energy saving is accomplished with ultra low power consumptionduring periods of non-use.
CARE FOR EARTH’S ENVIRONMENT
MORE POWERFUL SYSTEM ENGINE !
CAREFUL CONSIDERATION FOR THE USER
Industry First Full Touch Screen Panel
The Full Touch Screen Panel System automatically activatesthe unit’s operations through a simple touch to the desired icondisplayed on the screen.
TFT LCD Screen with a Clear Picture Tone
A 262,000 Color TFT LCD Display provides diverse information intrue vivid colors for user convenience.
Graphical User Interface
A Graphical User Interface is designed specifically for ease of useand operation. Communication between the user and ionizer hasnever been this simple!
Jog Dial & Touch with 2-Way Operation Compatibility
Choose from either the Jog Dial or the Touch Screen Panel system–both are available with 2-way operation compatibility and areeasy to use at your convenience
An Object that Offers both Kitchen Space & Ultimate Beauty
The Tyent’s Under Counter Extreme Water Ionizer not only attractsperson’s gaze with its well-differentiated appearance, but alsohelps to upgrade your kitchen’s interior decoration with a neatand luxurious expression.
A DESIGN MASTERPIECE
FULL TOUCH LCD – TRANSFORMATION AT YOUR FINGERTIPS
JOG DIAL & TOUCH
UCE-9000 Turbo user’s manual
14 15
Pro
duct
Feat
ures
Pro
duct
Feat
ures
Temperature Sensor Function for Safe Operation
If the temperature of the source water exceeds the normal operationrange of 4~35℃ degrees Celsius, the incoming flow of water is automatically interrupted, displaying a Warning Sign on screen.
Water Discharge Nozzle with Directional Control
The water discharge direction may be adjusted to many diverseangles based on user preference.
Automatic Water Discharge Interruption Function
In order to prevent the overflow of water due to user negligence,the water discharge is automatically stopped after 15 minutes of use.
Automatic Electrolysis Tank Cleaning Function
The interior of the Electrolysis Bath is automatically cleaned on aregular basis, ensuring stable electrolysis operating conditions.
Automatic Memory Function
The last function used by the user is automatically memorized anddisplayed on the Standby Screen for fast and convenient operation.
Convenience of Operating Condition Setting System
Easy Setting System familiar to common users is employed, allowingthe convenience of setting or canceling the desired through theLCD Screen.
Super Simple Filter Replacement System
A simple filter replacement system along with one-touch FilterUsage Initialization Setting System makes filter management easyfor any one.
pH Control Function
Respective alkali, acid & turbo phases can be easily controlledby the user.
Self Diagnosis Function
When the condition of the source water is not suitable, the waterdischarge is automatically suspended, displaying a Warning Signon screen.
Water Purification through Clean Processes and Minerals
Perfect, seamless elimination of foreign substances including residualchlorine, organic & inorganic compounds through the filtering processusing functional UF and ∏ Ceramic materials, enhancing the alkaliwater producing condition.
FRESH, PURIFIED WATER IS A MUST ALONG WITH HEALTHY MINERALS!
Real Time Filter Usage Indication and Replacement Time Guide
Level of filter usage can be identified through the LCD Screen ona real time basis. The recommended replacement time is automaticallydisplayed on the screen with a voice guide.
SELF MAINTENANCE MADE EASY – FROM INSTALLATION TO AFTER-SERVICE
UCE-9000 Turbo user’s manual
16 17
Part
s Dr
awing f
or
Inst
alla
tio
n
Packa
ge C
ont
ent
s
Parts Drawing for InstallationPackage Contents
Ionizer
rubber packing(2EA)
Wrench
pH TestingSolution Bottle
User’s Manual
Alkaline hose(White)
Acid hose(Orange)
Tap Waterhose
&
Water Outlet Pipe
fixing nut
MANUA
L
Stem Elbows(3EA)
dispenser
Cable Tie
Adapter
Dispenser
Rubber packing
Rubber packing
Fixing nut
Alkaline hose
Union connector
Acid hose
MCU cable connector
Alkaline outletStem elbow
Acid outletTap water inlet
MCU cable
Tap water hose
Acid hose
Alkaline hose
MCU cable
Adapter
Ionizer
Tap water hose
Cable tie
Bottom
Picture of components can be different from the real ones, and some items may be changed according to the situation.
32Ø
UCE-9000 Turbo user’s manual
18 19
Disp
ens
er
Inst
alla
tio
n
Unde
r-Sink
Inst
alla
tio
n
Under-Sink Installation
Purchase either an under-sink installation kit (not included) or purchaseT-connection (with shut-off valve) from a hardware or plumbing supplystore.
Shut off both hot and cold water main supply at pipe under the sink.
Locate the cold water supply line valve.
Disconnect faucet cold water supply line from main cold water pipe–usetowel to catch small amount of water that may come from faucet supplyline.
When connecting T-connection to cold water pipe, be sure to use plumbingpipe thread seal tape (not included) to prevent leaks.
Reconnect faucet cold water supply line to T-connection. (now securedto main cold water pipe)
Be sure all connections are secure but do not over tighten.
1.
2.
3.
4.
5.
6.
7.
*Do not turn on main water supply until all hoses are properly installed tothe unit.
Drain Pipe
Water Outlet Pipe
Dispenser Installation
First, the fixed nut to remove it from thedispenser.
1
Press the outflow pipes into the holes of thedispenser.*upper hole: water outlet pipe [152mm] *lower hole : drain pipe [102mm]
2
Use a 32Ø drill bit to drill the hole.4
Connect each hose from the ionizer to theunion connector. (when you connect thehoses, please match the hoses by color :orange ‒ orange, white ‒ white)
3
alkaline hose
acid hose
UCE-9000 Turbo user’s manual
20 21
Ionize
r Inst
alla
tio
n
Disp
ens
er
Inst
alla
tio
n
Place the assembled dispenser into thedrilled hole.
Insert one of the provided rubber O-Ringsin the assembled dispenser.
6
Tighten the fixing nut underneath the sink.(do not over tighten)
8
Insert the second rubber O-ring in theassembled dispenser located underneaththe sink.
7
5
tap water inlet
Ionizer Installation
Press the stem elbows into the water inflow,alkali outlet and acidic outlet located on thebottom of the ionizer.
1
Connect the hoses of the dispenser to thestem elbows. (when you connect the hoses,use orange for the acid hose and white forthe alkaline hose)
2
Connect the MCU cable of the dispenser tothe MCU cable on the bottom of the ionizer.
3
Connect the hose from the inflow hole tothe cold water supply at the under-sinkT-connection.
4
Make sure all hose connections are firmlyseated in the correct holes, both on theunit and at the water supply.
5
Primary Filter: 1st Filter
Recommended filter replacement cycle:951.0 gallons (3,600 L) / Every 6 months
Removes harmful chemicals like chlorine,compounds such as agrichemicals anddetergents, large suspended matters like rustand sediments as well as other volatile organiccompounds through an efficient, activatedabsorption method. It also eliminates badsmells and any remaining dissolved chlorine.
1st Filter
Secondary Filter: 2nd Filter
Recommended filterreplacement cycle:951.0 gallons (3,600 L) / Every 6 months
0.01 micrometer artificial film filters contaminatedmaterials including ordinary bacteria whilemaintaining essential minerals in the water.
2nd Filter
Customer Serviceable Parts
The life of the filter may vary greatly due to use, water pressure, water quality andseasonal changes. Filters may need to be replaced sooner than the scheduledtime due to these varying conditions, as you may notice reduced water quality orwater taste changing for the worse.
ATTENTION: The consumer accepts any and all responsibility and/or liability ifreplacement filters and/or parts are not manufacturer specific. This unit containshigh-performance purifying filters and an advanced control system.
UCE-9000 Turbo user’s manual
22 23
Cus
tomer
Serv
iceab
le P
arts
Ionize
r Inst
alla
tio
n
Caution
In the event of a power failure Remove the power cord from electrical socket and shut off source watervalve.
Plug in the power cord and turn on the unit.6
※ INTRO Screen appears only when Initial Power is supplied.
UCE-9000 Turbo user’s manual
24 25
Ho
w t
o R
ese
t th
e F
ilters
Ho
w t
o C
han
ge t
he F
ilters
1
How to Change the Filters
Turn the power off and unplug the power cord. Shutoff the water supply to the unit. Make sure the faucetis shut off.
2 Open the front door of the unit. Beware of the sharpcorners of the cover of the unit when opening.
3 Pull the filter towards you so that it will be easier toturn. The filter will turn more freely when tilted at aslight angle. Remove the filter by rotating the filtercounter-clockwise. Install the new filter by turningit clockwise. Hand tighten only. Tilt the filter backinto its original upright position.
4 Close the cover of the unit.
5 Plug the power cord back in, re-engage the watersupply and switch the unit back on.
open
separate
connect
How to Reset the Filters
How to Change the Fuse
1. First Filter Reset① Press the bottom part of LCD Screen. MENU Window appears upper the bottom part of LCD Screen.② To initialize, press the “F1 RESET” icon 2 times. *LCD : percentage (%) of initialization of filter
① Press the bottom part of LCD Screen. MENU Window appears upper the bottom part of LCD Screen.② To initialize, press the “F2 RESET” icon 2 times. *LCD : percentage (%) of initialization of filter
2. Second Filter Reset
Use the Filter Initialization Icon only after Filter is changed.CAUTION!
1. Unplug the power cord.2. Locate the fuse cap on the lower back of the unit and turn it counter- clockwise to remove it.3. Pull out the blown fuse and insert a new fuse.4. Replace the fuse cap.
Important InformationPlease be sure to contact manufacturer to obtain the correct fuse. Customer accepts allreponsibility for damage to unit and other property due to the installation of incorrect fuse.
1 2
1 1st filter reset icon
2 2nd filter reset icon
7
1 2 3 4
1 2
Operation Touch Screen
UCE-9000 Turbo user’s manual
26 27
Ope
ratio
n To
uch S
cre
en
Ope
ratio
n To
uch S
cre
en
Display Line of the Set Status
Functional Water Operation
standby mode 1
Display Line of the used amountof a Filter[intial: 00%,]
alkaline level 3
purified water
turbo water
acidic level 1
acidic level 2
acidic level 3
1st filter life indicator
2nd filter life indicator
Icon : description
setup
voice on
voice off
cleaning
eco mode on
eco mode off
alkaline level 1
alkaline level 2
Menu window2
1 setup mode (ref. 32p)
2 voice on/off (ref. 36p)
3 cleaning (ref. 37p)
4 eco mode on/off (ref. 38p)
1 1st filter reset icon
2 2nd filter reset icon
Use the Filter Initialization Icon only after Filter is changed.(ref 25p)
Push the upper part of LCD Screen. MENU Window appears belowthe upper part of LCD Screen.
Push the bottom part of LCD Screen. MENU Window appears abovethe bottom part of the LCD Screen.
CAUTION!
selected mode
auto flow stop time indicator
UCE-9000 Turbo user’s manual
28 29
Ope
ratio
n To
uch S
cre
en
Ope
ratio
n To
uch S
cre
en
LCD Display3
working indicator
Backlight of LCD display will match the pH level color according to water pHlevel being used after icon is pressed.
IMPORTANT
Clean WaterGreen Back-LightDeep Pink Back-Light
TurboRed Black Back-Light
Acidic Water 3Acidic Water 2Orange Back-Light
Acidic Water 1Yellow Back-Light
Alkaline Water 1Sky Blue Back-Light
Alkaline Water 2 Blue Back-Light
Alkaline Water 3Violet Back-Light
Message Display4
CAUTIONS in using the TOUCH Screen
Due to the uniqueness of the TOUCH Screen, TOUCH is not recognized ifpushed by more than one finger. Please push with only one finger and becareful of contamination to the screen that may cause damage to the TOUCH.
Be careful of electrostatic materials near the TOUCH Screen. Stimulation fromsuch materials may cause damage to the TOUCH.
Screen may not be seen well under direct sunlight.
Do not push the Screen hard with sharp or pointy objects.
1.
2.
3.
4.
filter replacement: : Filter replacement message
temperature error: : Should water with a temperature higher than 95F (35℃) get into the unit, the water supply will automatically be shut off and the unit will stop operating.
outflow stop: : In the event of suspen sion of water supply, a warning message is issued prior to stopping water outflow.
Cleaning takes place automatically and/or manually: : Auto Cleaning (15 Seconds) •Performed during water outflow after more than 12 hours of non-operation •Performed after 30 liters of water outflow : : Manual Cleaning (15 Seconds) •User may manually clean unit whenever desired. Simply touch icon.
UCE-9000 Turbo user’s manual
30 31
Unit u
sage
Unit u
sage
Unit Usage
When TOUCH Screen is used1
Mode SelectionPress the desired icon on LCD Screen.
1
Water OutflowWater outflow starts.* LCD Display: Current Outflow Level and Auto flow Stop time are displayed.
2
Water Outflow StopPress the screen to stop the flow.
3
Standby ModeMoves to standby mode screen.(Last used icon is displayed.)
4
When JOG Dial is used2
Mode SelectionTurn the JOG Dial clockwise (or counterclockwise) to select desired function.* LCD Display: White edge is displayed around the selected icon.
1
Standby ModeMoves to standby mode screen.(Last used icon is displayed.)
4
◀J
OG
DI A L ▶
◀JOG DIA
L▶
◀J
OG
D
IA
L▶
Water Outflow After checking the selected icon onLCD screen, push the area of“PUSH ON/OFF”of the JOG Dial.
Water outflow starts.
2
◀J
OG
DI A L ▶
◀JOG DIA
L▶
◀J
OG
D
IA
L▶
Water Outflow StopPress the “PUSH ON/OFF”of the JOG Dial to stop the flow.
3
◀J
OG
DI A L ▶
◀JOG DIA
L▶
◀J
OG
D
IA
L▶
SYSTEM SETUP METHOD
UCE-9000 Turbo user’s manual
32 33
SYST
EM S
ETUP
MET
HO
D
SYST
EM S
ETUP
MET
HO
D
Alkali pH Level Adjustment1
4
3
Select desired level.
: LEVEL UP (14%, 15%, 16%.....)
4
5
: LEVEL DOWN (12%, 11%, 10%.....)
Select “ALKALI pH”3
Press the upper part of LCD Screen. MENU Window appears below the upper part of LCD Screen.
1
Press the setup icon 2
Push the RETURN Icon : Move upward by one step.
Acidic pH Level Adjustment2
3
3
Press the upper part of LCD Screen. MENU Window appears below the upper part of LCD Screen.
1
Press the setup icon 2
Select “ACIDIC pH”
1
2
1
2
* If UP/DOWN Icon is pushed, digital number moves by one step
Setup is completed
5 4
Select desired level.
: LEVEL UP (18%, 19%, 20%.....)
4
5
: LEVEL DOWN (16%, 15%, 14%.....)
Push the RETURN Icon : Move upward by one step.
* If UP/DOWN Icon is pushed, digital number moves by one step
Setup is completed
5
UCE-9000 Turbo user’s manual
34 35
SYST
EM S
ETUP
MET
HO
D
SYST
EM S
ETUP
MET
HO
D
TIME4
3 Select “TIME”
4 Adjustment :
- (17, 18, 19 ..... 24)
- (16, 15, 14 ..... 0)
/
Year
Month
Date
Hour
Minute
ⓐ
ⓑ
ⓒ
ⓓ
ⓔ
3
4
Push the RETURN Icon : Move upward by one step.
Press the upper part of LCD Screen. MENU Window appears below the upper part ofLCD Screen.
1
Press the setup icon 2
1
2
Volume Level Adjustment3
3 Select “VOLUME”
4 4
3
Push the RETURN Icon : Move upward by one step.
Press the upper part of LCD Screen. MENU Window appears below the upper part of LCD Screen.
1
Press the setup icon 2
Select desired VOLUME : Select desired VOLUME by pushing +.– Icon.Setup is completed.
4 ,
1
2
Setup is completed.
UCE-9000 Turbo user’s manual
36 37
Man
ual Cle
aning F
unctio
n
Voic
e O
n/O
ff S
ele
ctio
n
Manual Cleaning Function Voice On/Off Selection
Press the upper part of LCD Screen. MENUWindow appears below the upper part ofLCD Screen.
1
Cleaning mode is operated.[ cleaning time : 15 sec.]
User may manually clean unit whenever desired.
Press the upper part of LCD Screen. MENU Window appears below the upper part of LCD Screen.
1
3
2 Select CLEANING icon.Select Voice icon.2
3 Whenever you press the voice iconshortly, you can change in this sequence.
UCE-9000 Turbo user’s manual
38 39
TURB
O F
unctio
n
ECO
MO
DE
ECO MODE TURBO Function
If the Screen is pushed, it is changed into StandbyScreen Mode.
Whenever you press the eco iconshortly, you can change in this sequence.
ECO Mode is a feature for saving power consumption during periods of non-use.
1
2
3
The TURBO Function allows you to create strong alkaline and acidic water.These types of water are ONLY to be used for cleaning, sanitizing anddisinfecting purposes.
TURBOStrong Acidic Water
pH 2.5~ pH 3.8
Used to Disinfectand Sterilize
TURBO Strong Alkaline Water
pH 10.0~ pH 11.8
To remove stains fromfabrics/carpet/upholstery.
CAUTION!
The waters produced in TURBO mode are not intended for drinking.DO NOT DRINK these types of waters.DO NOT Use the TURBO function in a manner other than directed.
Alkaline Turbo Water Outflow Acidic Turbo Water Outflow
Press the upper part of LCD Screen. MENUWindow appears below the upper part ofLCD Screen.
When the ECO Mode is set,the LCD Screen isn’t displayed anything.
UCE-9000 Turbo user’s manual
40 41
Reco
mmend
atio
ns f
or
using t
his u
nit
Reco
mmend
atio
ns f
or
using t
his u
nit
Recommendations for using this unit
Light Alkaline Water(Drinking Level 1)
Suitable for initial stage of drinking.
Medium Alkaline Water(Drinking Level 2)
For making coffee, tea and forwatering plants.
Strong Alkaline Water(Drinking Level 3)
For washing vegetables, dishesand making rice.
Clean Water
Creates purified water. Fortaking medications and makingbaby formula.
Light Acidic Water(DO NOT DRINK)
For washing hands, face.
Medium Acidic Water(DO NOT DRINK)
For washing vegetables and fruits.
Strong Acidic Water(DO NOT DRINK)
For washing dishes.
TURBO Function
DO NOT DRINK. Strong acid/alkaline water that must be usedwhen cleaning, disinfecting, washingand sterilizing.
UCE-9000 Turbo user’s manual
42 43
Unit S
pecificat
ions
Ho
t W
ater
Sens
or
Temperature Sensor
1. Should water with a temperature higher than 95℉ (35℃) get into the unit, the water supply will automatically be shut off and the unit will stop operating.
2. LCD: “TEMP ERROR”
In flow
4℃ or 35℃
Unit Specifications
Product Name
Model Number
Purifying Mode
Rated Power
Power Consumption
Available temperature
Operating Pressure Range
pH Levels
Adjustable pH
Filters Configuration
Filter Life Display
Electrolytic Cell Quantity of Poles
Water Cell Plate Materials
Product Size
Product Weight
Water Ionizer
UCE-9000 Turbo
TM Filtration Mode
AC100V~AC130V, AC200~AC240V/50Hz~60Hz
Max. 374.4 VA
39º-95º F (4º-35º C)
0.1 ~ 0.5MPa
3 Alkaline, 1 Neutral, 3 Acidic, Turbo
User adjustable pH levels control
2 Filters System
LCD filter replacement and announcement
9
Platinum and Titanium
Ionizer : 14.1(W) x 5.2(D) x13.9(H) inchesDispenser : 2(D) x 12.7(H) inches
Dispenser : 1.1 Lbs / Ionizer : 15.2 Lbs
Troubleshooting
UCE-9000 Turbo user’s manual
44 45
Reco
mmend
atio
ns f
or
using t
his u
nit
Reco
mmend
atio
ns f
or
using t
his u
nit
Before requesting service, please make sure to check the following :
1. Water tastes abnormal
A. Check how long the unit has not been in use i. Operate the unit normally for a few minutes to drain stagnant water.
B. Check to see if the filters need replacing. i. Call to have the filter replaced.
2. NO water outflow or the amount of water generated is different from specified
A. Be sure the water supply is on i. Open the valve
B. Check if the hose is bent or folded i. Stretch out the hose
C. Check power settings. i. Enter setup mode and check power settings.
D. Check the purifying filter for clogs i. Replace filter
3. Incorrect pH levels (additional pH reagent drops can be ordered for a fee)
A. Check water supply for hardness i. pH levels may vary depending on region and water quality
B. Check flow rate for higher levels i. Slow down water supply
A. Follow the filter reset instructions i. Contact the service center to initialize the filter flow rate in the System Setting Mode
4. The filter replacement icon remains turned on even after filter has been replaced
5. The unit automatically stops while it’s producing functional water
A. Check if the continuous operating time exceeds 15 minutes i. Water production stops automatically after 15 minutes to prevent accidental over flooding.
6. Leaks from the Filter or Unit
A. Check the filter is installed correctly
7. Hazy substance settles down on the bottom of the container filled with functional water
A. Check if calcium ions and carbonic acids bond together in water forming deposits i. Depending on the quality of raw water, calcium is extracted from the water. There is no problem in drinking water with calcium. However, it is recommended that you contact the service center in case it is a recurring problem.
8. The unit doesn’t operate in cleaning mode A. Check if the amount of working water exceeds 6.5 gallons (30 L)
B. Check if the operating time exceeds 12 hours
B. Check the inside of the product (excluding the filters) for any signs of leaks i. Immediately unplug the power cord and contact the service center ii. Be sure all hoses are firmly seated in correct connections.
UCE-9000 Turbo user’s manual
46 47
Reco
mmend
atio
ns f
or
using t
his u
nit
Reco
mmend
atio
ns f
or
using t
his u
nit
We cannot accept any responsibility or liability for errors and/or problems rising from the customer's use of parts that aren't manufactured by our company.
www.tyentgroup.com
15-2, Pyeongsan-Dong, Yangsan-si, Gyeongsangnam-do, Korea TEL.82-55-363-6670 FAX. 82-55-363-6674
Product Warranty
Product Name
Model Number
Date of Purchase
Customer's Name
Customer's Address
Installation Engineer Name
Customer's Phone
One Years from the Date of Purchase [12months]
Warranty PeriodWater Ionizer
UCE-9000 turbo
1. This product is warranted for one year (12 months). Any manufacturing defects or spontaneous failures that may occur during the warranty period will be repaired or replaced at no charge.
2. If any failure occurs, please call for service.
3. In the following cases, the customer shall pay repair or replacement costs. - In the case where a failure occurs resulting from improper use or negligence by the customer. - In the case where repairs or modifications are performed by non-authorized representatives. - In the case where a failure due to natural disasters (fires, salt damage, damage from natural gas, earthquakes, floods, lightning, and etc.) - In the case of absence of the product warranty or no information is provided in the warranty. - Usage other than domestic use.
4. We shall charge the customer for repairs and replacement costs against failures after the warranty period expires.(one year after the date of purchase).
5. Our customers are asked to show their warranty to us when requesting after-sales service.