Sun Fire X2100/X2200 M2 TechnicalProduct Training Presentation
SunWin Token # 478550
Ronald GrahamSystems Group Technical MarketingSun Microsystems
Sun Confidential : Sun/Partners Use Only2
Agenda
• Introduction and Positioning• Server Architecture
> Sun Fire X2200> Sun Fire X2100> Enabling Technologies
• Embedded Light Out Management • Operating Systems• System and Upgrade Options
Sun Confidential : Sun/Partners Use Only3
Ultra 40Ultra 40 Ultra 20Ultra 20
Sun Fire X4150Sun Fire X4150
Sun FireSun FireX4500X4500X4540X4540
Sun FireSun FireX4200X4200X4100X4100
Sun Fire X2100Sun Fire X2100
Sun Blade 8000Sun Blade 8000
Sun’s x64 System PortfolioSun GridSun Grid
Rack SystemRack System
Sun Fire X2200Sun Fire X2200
NewNew Hybrid Data
Server
First & Only8-socket/16-way
AMD Server
Systems Refresh Throughout 2008
Voted“Best Enterprise
Server”InfoWorldInfoWorld
Voted“Best High Perf
Server”InfoWorldInfoWorld Sun Fire Sun Fire
X4600X4600
Sun Blade 6000Sun Blade 6000
Sun Fire X4450Sun Fire X4450
Sun Fire X4140Sun Fire X4140X4240X4240
Sun Fire X4440Sun Fire X4440
Sun Fire X4250Sun Fire X4250
Sun Blade 6048Sun Blade 6048
Sun Fire X2250Sun Fire X2250
Sun Confidential : Sun/Partners Use Only4
Sun Fire Features SummaryFeatures Sun Fire X2100 M2 Sun Fire X2200 M2
Form Factor 1U 1U
Processor
BIOS AMI BIOS AMI BIOSMemory DIMM slots 4 DIMM slots 8 DIMM slots per CPUMemory Types DDR-2 667MHz Registered DIMMs with ECCMemory Module Sizes 512MB, 1GB, 2GB DIMMs 1GB,2GB, 4GB DIMMsMax Memory 8 GB 64 GB
HDD Controller
HDD Type 3.5-inch drives 3.5-inch drivesHDD Number 2 HDDs 2 HDDsOptical Drive DVD-ROM DVD-ROM
NIC Controller
NICs Four Gigabit Ethernet NICs Four Gigabit Ethernet NICsGraphics Controller AST2000 AST2000
Expansion Slots
Front I/O Six USB 2.0 ports Six USB 2.0 ports
Rear I/O
Power supply Single 345Watt Single 450Watt
Systems ManagementOS Support Solaris, Linux and Windows
1x Dual-Core AMD Opteron processor Model 1200 CPUw/ 1MB L2 Cache per Core
Up to 2 Dual-Core or Quad-Core AMD Opteron 2000 series processors w/ 4x 128 KB L1, 4x 512 KB L2, and 2MB or 6MB of shared L3 Cache
DDR-2 667MHz Un-bufferred DIMMs with ECC
Integrated Nvidia MCP55Serial ATA II
Integrated Nvidia MCP55Serial ATA II
Dual Integrated nVidia MCP55Broadcom BCM5715C
Dual Integrated nVidia MCP55Broadcom BCM5715C
Two PCI-E x8 Slots(or One PCI-E x16 Slot by optional Riser Q4CY06)
Two PCI-E x8 Slots(or One PCI-E x16 Slot by optional Riser Q4CY06)
Four Gigabit Ethernet ports (RJ45)One RS-232 Serial (DB9)
Four USB 2.0 ports (Type A)VGA Video port (HD15)
Four Gigabit Ethernet ports (RJ45)One RS-232 Serial (DB9)
Four USB 2.0 ports (Type A)VGA Video port (HD15)
Service Processor supporting Graphics redirection, Remote Floppy/CD/DVD, IPMI 2.0, SNMP, CLI and Web interface
Service Processor supporting Graphics redirection, Remote Floppy/CD/DVD, IPMI 2.0, SNMP, CLI and Web interface
Solaris, Linux, Windows, and VMware
Sun Confidential : Sun/Partners Use Only5
Agenda
• Introduction and Positioning• Server Architecture
> Sun Fire X2200> Sun Fire X2100> Enabling Technologies
• Embedded Light Out Management • Operating Systems• System Options
Sun Confidential : Sun/Partners Use Only6
One of the Industry's Fastest 2-socket Server for processing memory-intensive applications
Ideal for Web Infrastructure, HPC, Simulations, Financial Modeling
Excellent for EDA
Compute● Dual- or Quad-Core● 1 or 2 AMD Opteron™ 2000 series processors● 1U-rackmount● Up to 64GB with 16 DIMM Slots (4 GB DIMMs)
I/O● 2 x 8-lane PCI Express slots (Optional 1 x 16-Lane) ● 4 x GigE standard, USB 2.0, Video, Serial ports● DVD● Up to 2 TB of storage with 2 x SATA 3.5” disk drives
Availability● Hot-pluggable disk● RAID 0 or 1 (Optional)
Management● Embedded LOM Service Processor● Remote power on/off/status, GUI+CLI, IPMI 2.0, SNMP● Remote KVM, Floppy/CDROM
Operating Environment● Solaris, Linux, Windows, Vmware
Sun Fire X2200 M2
The 1U Server Workhorse
Sun Confidential : Sun/Partners Use Only7
Sun Fire X2200 M2 System Layout
Sun Confidential : Sun/Partners Use Only8
X2200 Architectural Block DiagramSATA II only
Marvell88E1121
PHY
Marvell88E1121
PHY
PCI 32bit/33MHz
USB 2.0USB 2.0
4 x USB 2.0
BCMNIC 0
nVidia NIC 1
BCMNIC 1
nVidia NIC 0
Serial
VGAVideo
Front PanelUSB Ports
UltraATA 1332 x USB 2.0
SATA II 3.0Gb/sSATA II 3.0Gb/s
Tray LoadDVD ROM
RearVGA
HD15
SerialPortDB9
RearUSB
Ports
UMPPort
SharedELOM NIC
Port
HT bus (8GB/s)
HT bus(8GB/s) DDR-2
5.3GB/s
DDR-25.3GB/s
DDR-25.3GB/s
DDR-25.3GB/s
Dual x8 PCI-E RiserorSingle x16 PCI-E Riser
MCP55MCP55
x16 PCI-E bus (4GB/s)
3.5”SATADisk Drive
3.5”SATADisk Drive
8DDR-2DIMMSSlots
8DDR-2DIMMSSlots
AMD Opteron 2000Series CPU
AMD Opteron 2000Series CPU
SuperIOLegacyDevice
BIOSFLASHPROM
LPC bus
nVidiaNIC 0
nVidiaNIC 1
x4 PCI-E bus (1GB/s)FrontPanel
RearPanel
Sun Confidential : Sun/Partners Use Only9
X2200 Architectural Block DiagramHBA – SATA II or SAS
Marvell88E1121
PHY
Marvell88E1121
PHY
PCI 32bit/33MHz
USB 2.0USB 2.0
4 x USB 2.0
BCMNIC 0
nVidia NIC 1
BCMNIC 1
nVidia NIC 0
Serial
VGAVideo
Front PanelUSB Ports
UltraATA 1332 x USB 2.0
SATA II or SAS
SATA II or SAS
Tray LoadDVD ROM
RearVGA
HD15
SerialPortDB9
RearUSB
Ports
UMPPort
SharedELOM NIC
Port
HT bus (8GB/s)
HT bus(8GB/s) DDR-2
5.3GB/s
DDR-25.3GB/s
DDR-25.3GB/s
DDR-25.3GB/s
Single x16 PCIe RiserorDual x8 PCIe Riser
MCP55MCP55
x16 PCI-E bus (4GB/s)
3.5”SATA or SAS Disk Drive
3.5”SATA or SAS Disk Drive
8DDR-2DIMMSSlots
8DDR-2DIMMSSlots
AMD Opteron 2000Series CPU
AMD Opteron 2000Series CPU
SuperIOLegacyDevice
BIOSFLASHPROM
LPC bus
nVidiaNIC 0
nVidiaNIC 1
x4 PCIe bus (1GB/s)FrontPanel
RearPanel
HBA
Sun Confidential : Sun/Partners Use Only10
Sun Fire X2200 M2 Internals TourPCI-ExpressRiser Area
BroadcomNICs
Power Supply
Memory/PCI FansCPU0 & 8x Memory Slots
Nvidia NICs& USB ports
Disk 0
Dual CPU/memory Blowers
CD/DVDDrive
Disk 1
Front PanelPCB
Embedded SP
Serial & Video ports
nVidia MCP55
CPU1 & 8x Memory Slots
Sun Confidential : Sun/Partners Use Only11
Sun Fire X2200 M2 Motherboardx16 PCI-Express
Riser Slot
Broadcom BCM5715 NIC
CPU 0
Nvidia NICs& USB ports
Embedded Lights OutManager (SP)
Serial & Video ports
nVidia MCP55
CPU 1,8 x Memory DIMM Sockets
CPU 1
CPU 0,8 x Memory DIMM Sockets
Sun Confidential : Sun/Partners Use Only12
Sun Fire X2200 Processors
Special EditionSE
Standard Parts
High EfficientHE
TDP ACP105W137W
TDP ACP 75W 115W
TDP ACP 55W 79W
TDP ACP105W120W
TDP ACP 75W 95W
TDP ACP 55W 68W
TDP – Thermal Design Power ACP – Average CPU Power
Second Generation Third GenerationSanta Rosa Socket F Barcelona/Shanghai
Dual-Core Quad-Core
Sun Confidential : Sun/Partners Use Only13
AMD Model Number Overview4 digit AMD Opteron Processor Model - 1234
Model Number communicates scalability, generation and relative performance● 1st digit communicates scalability -- represents maximum number of processors supported
● 1-socket AMD Opteron processor = 1000 Series, Model 1xxx● 2-socket AMD Opteron processor = 2000 Series, Model 2xxx● 8-socket AMD Opteron processor = 8000 Series, Model 8xxx
● 2nd digit represents the generation of AMD Opteron processor● Model 2216 is 2nd generation [DDR2, Dual-Core, Socket F (1207)] & 2-Socket capable● Model 2356 is 3rd generation [DDR2, Quad-Core, Socket F (1207)] & 2-Socket capable● Third generation includes Barcelona and Shanghai
● 3rd and 4th digits communicate relative performance within product line● For example, Model 8216 would offer
● Better performance than a Model 8212● Lower performance than a Model 8220
• Continued Drop-in Upgradeability Investment protection
• Shanghai Model numbers• 8/2376 (2.3GHz) 8/2378 (2.4GHz), • 8/2380 (2.5GHz) 8/2382 (2.6GHz)• 8/2384 (2.7GHz)
Sun Confidential : Sun/Partners Use Only14
Enhancements in Shanghai
2MB of L3 cache 6MB of L3 cacheBetter performance
New in Shanghai
65nm Technology45nm Technology
Immersion LithographyBetter clock speed scaling
AMD Balanced Smart CacheAMD Smart Fetch
Allows cores to sleep whilestill providing full cache access
HyperTransport 1.0 @2GT/s (8GB/s)
HyperTransport 3.0 @4.4GT/s (17.6GB/s)
Available Spring '09 (not all platforms)
AMD CoolCore Technology Extends power savings to L3 cache(L3 powered down when not in use)
AMD-V withRapid Virtualization Indexing
Designed for 25% fast “world switch” timeEnhanced Rapid Virtualizaton Indexing
(More Virt-Phys translation held in cache)
Quad-Core AMD Opteron Features“Barcelona”
2MB of L3 cache 6MB of L3 cacheBetter performance
65nm Technology45nm Technology
Immersion LithographyBetter clock speed scaling
AMD Balanced Smart CacheAMD Smart Fetch
Allows cores to sleep whilestill providing full cache access
AMD CoolCore Technology Extends power savings to L3 cache(L3 powered down when not in use)
Sun Confidential : Sun/Partners Use Only15
AMD Balanced and Smart Cache
Integrated Memory Controller
Cache
Control
512KB
Core 4
128KB
Cache
Control
512KB
Core 3
128KB
Cache
Control
512KB
Core 2
128KB
Cache
Control
512KB
Core 1
128KB
New 6MB
• Dedicated L1 AMD’s 64KB/64KB vs. Intel’s 32KB/32KB Allows 2 loads per cycle versus their one Latency 3 cycles to L1
• Dedicated L2 Dedicated cache to eliminate conflicts
common in shared caches Sized to accommodate the majority of
working sets today Latency 12 cycles to L2
• Shared L3 - New Optimized memory use and allocation for
multi-core Non-inclusive victim cache architecture Latency <38 cycles to L3
• Low latency access to external DRAM (<60ns)
• Upon a full cache miss (L1, L2 & L3) data is sub 60ns away
• All memory ranks are the same latency from the CPU
Sun Confidential : Sun/Partners Use Only16
AMD Virtualization™ (AMD-V™)• Faster World Switch - A “world switch” is when CPU control passes from one Guest
OS, to the hypervisor, to another Guest OS (or back to the original one). Faster switching means the CPU can get back to work on running the virtualized application.
• Rapid Virtualization Index works by caching the address translations from Guest Virtual memory to Guest Physical memory to Host Physical memory. To translate between each of these states can require dozens of incremental translations. Shanghai improves Rapid Virtualization Indexing over Barcelona by caching more of these incremental address translation steps.
● BenefitsVirtualization at hardware level
supports more users while offering best performance
Vmware support in 3.5 Update 1Xen support today
120
VM
VM
VM
VM
VM
VM
VM
VM
VM
VM
VM
VM
Local
LocalLocal
Local
Home
Node
Home
Node
Home
Node
Home
NodeRemote
RemoteRemote
Sun Confidential : Sun/Partners Use Only17
Dual Dynamic Power Management Compatibility Mode
● Today’s AMD Opteron™ processor use a unified voltage plane for the Memory Controller and Core
● Quad-Core processors can work in unified plane motherboards but they will not offer the benefits of Dual Dynamic Power Management (DDPM) described below
Dual Dynamic Power Management
● The power for the CPU and Memory Controller from independent voltage supplies, offering greater performance and better power management
● Second-Generation AMD (Rev F) Opteron processors are compatible with motherboards designed to support DDPM but they will deliver the same voltage to the CPU and Memory Controller power
Unified PowerSupply
2.0 GHz
1.6 GHz
System Request Queue
Crossbar
Hypertransport
MemoryController Memory Controller
Power
CPU Power
2.0 GHz
1.8 GHz
System Request Queue
Crossbar
Hypertransport
MemoryController
AMD-V Extended Migration• Vmware Enhanced Vmotion (EVC) support
– Version 3.5 update 2
• Better Vmotion and CPU compatibility• Vmotion technology allows users to migrate running virtual machines
between compatible physical servers with zero downtime– Automatically mask to disable features (SSE4.1)
Cache
Control
Rev ESingle-Core Dual-Core
2005 2006 2007 2008 2009 >2010
EVC support for AMD Opteron processorsstarts with Rev E for 2 Socket, 4 socket, and 8 socket Servers
Rev F
“Barcelona”
“Shanghai”
Future Processors
Sun Confidential : Sun/Partners Use Only19
AMD Smart Fetch Technology
• Reducing power and increase performance> Reduces cache probes
which can increase performance for non-halted cores
> Flushes its L1 & L2 caches (to L3) and sets a flag so other cores know it doesn’t have any data that they need
IDLE MHz
75%
IDLE MHzCORE 0 CORE 1
35%
IDLE MHz
10%
IDLE MHzCORE 2 CORE 3
0
Shanghai Quad-CoreShanghai Quad-Core
IDLE MHz
75%
IDLE MHzCORE 0 CORE 1
35%
IDLE MHz
10%
IDLE MHzCORE 2 CORE 3
1%
Barcelona Quad-CoreBarcelona Quad-Core
Clock can be significantly reduced but has to be ready to increase frequency in the event of a cache
request
Other cores are informed that it doesn’t
have any data.
Clock can be completely turned off
Sun Confidential : Sun/Partners Use Only20
Agenda
• Introduction and Positioning• Server Architecture
> Sun Fire X2200> Sun Fire X2100> Enabling Technologies
• Embedded Light Out Management • Operating Systems• System Options
Sun Confidential : Sun/Partners Use Only21
One of the Most Energy-Efficientand Highest Performing
2-way Server at a Great Price
Ideal for Web Infrastructure, HPC, Simulations, Financial Modeling
Excellent for Life Sciences
Compute● 1-socket 2-way server (Dual Core only)● AMD Opteron™ processor Model 1200● 1U-rackmount● Up to 8 GB of memory with 4 DIMM Slots
I/O● 2 x 8-lane PCI-Express slots (1 x 16-Lane) ● 4 x GigE standard, USB 2.0, Video, Serial ports● DVD● SAS or SATA II Drives● Up to 2 TB of storage with 2 x SATA 3.5” disk drives
Availability● Hot-pluggable disk● RAID 0 or 1 (Optional)
Management● Embedded ILOM Service Processor● Remote power on/off/status, GUI+CLI, IPMI 2.0, SNMP● Remote KVM, Floppy/CDROM
Operating Environment● Solaris, Linux, Windows
Sun Fire X2100 M2
The 1U Server
Sun Confidential : Sun/Partners Use Only22
Sun Fire X2100 M2 System Layout
Sun Confidential : Sun/Partners Use Only23
FrontPanel
RearPanel
X2100 Architectural Block DiagramSATA II
Marvell88E1121
PHY
Marvell88E1121
PHY
PCI 32bit/33MHz
USB 2.0USB 2.0
4 x USB 2.0
BCMNIC 0
nVidia NIC 1
BCMNIC 1
nVidia NIC 0
Serial
VGAVideo
Front PanelUSB Ports
UltraATA 1332 x USB 2.0
SATA II 3.0Gb/sSATA II 3.0Gb/s
Tray LoadDVD ROM
RearVGA
HD15
SerialPortDB9
RearUSB
Ports
UMPPort
SharedELOM NIC
Port
HT bus (8GB/s)
Dual x8 PCIe RiserorSingle x16 PCIe Riser
MCP55MCP55
x16 PCIe bus (4GB/s)
3.5”SATADisk Drive
3.5”SATADisk Drive
DDR-25.3GB/s
DDR-25.3GB/s
4DDR-2DIMMSSlots
AMD Opteron 1200Series CPU
SuperIOLegacyDevice
BIOSFLASHPROM
LPC bus
nVidiaNIC 0
nVidiaNIC 1
x4 PCIe bus (1GB/s)
Sun Confidential : Sun/Partners Use Only24
FrontPanel
RearPanel
X2100 Architectural Block DiagramHBA – SATA II or SAS
Marvell88E1121
PHY
Marvell88E1121
PHY
PCI 32bit/33MHz
USB 2.0USB 2.0
4 x USB 2.0
BCMNIC 0
nVidia NIC 1
BCMNIC 1
nVidia NIC 0
Serial
VGAVideo
Front PanelUSB Ports
UltraATA 1332 x USB 2.0
SATA II or SAS
SATA II or SAS
Tray LoadDVD ROM
RearVGA
HD15
SerialPortDB9
RearUSB
Ports
UMPPort
SharedELOM NIC
Port
HT bus (8GB/s)Single x16 PCIe RiserorDual x8 PCIe Riser
MCP55MCP55
x16 PCIe bus (4GB/s)
3.5”SATA orSAS Disk Drive
3.5”SATA orSAS Disk Drive
DDR-25.3GB/s
DDR-25.3GB/s
4DDR-2DIMMSSlots
AMD Opteron 1200Series CPU
SuperIOLegacyDevice
BIOSFLASHPROM
LPC bus
nVidiaNIC 0
nVidiaNIC 1
x4 PCIe bus (1GB/s)
HBA
Sun Confidential : Sun/Partners Use Only25
Sun Fire X2100 M2 Internals TourPCI ExpressRiser Area
BroadcomNICs
Power Supply
PCI Fan*CPU & 4 x Memory Slots
Nvidia NICs& USB ports
Disk 1
CPU/memoryBlowers
CD/DVDDrive
Disk 0
Front PanelPCB
Embedded Lights Out Manager (SP)
Serial & Video ports
nVidia MCP55
*Only 1x Fan for PCI Cooling in Final Design
Sun Confidential : Sun/Partners Use Only26
Sun Fire X2100 M2 Motherboard Tourx16 PCI-Express
Riser Slot
Broadcom BCM5715 NIC
CPU
Nvidia NICs& USB ports
Embedded Lights OutManager (SP)
Serial & Video ports
nVidia MCP55
4 x DIMM Sockets
Sun Confidential : Sun/Partners Use Only27
Agenda
• Introduction and Positioning• Server Architecture
> Sun Fire X2200> Sun Fire X2100> Enabling Technologies
• Embedded Light Out Management • Operating Systems• System Options
Sun Confidential : Sun/Partners Use Only28
Sun Fire X2100 & X2200 M2 Product TourFront Panel
Hot Swappable Disks
Optional CD/DVD Drive
Dual USB 2.0Ports
Power ButtonSystem LED
Service/FaultLED
LocateButton/LED
Sun Confidential : Sun/Partners Use Only29
Sun Fire X2100 & X2200 M2 Product TourRear Panel Dual x8 PCI-Express
Slotsor
One x16 PCI-Express Slot
VGA VideoHD15 port
Quad USB 2.0Ports
Dual nVidiaGbE ports
SystemLED
Service/FaultLED
LocateLED
Serial DB9 portDual
BroadcomGbE ports
Power Supply(X2100 has no
visible Fan)
Sun Confidential : Sun/Partners Use Only30
Sun Fire X2100 & X2200 M2 Product Tour Rear Ports and Ethernet Port naming
VGA VideoHD15 port
Quad USB 2.0Ports
Dual nVidiaGbE ports
Serial DB9 port
Dual BroadcomGbE ports
OS Solaris RHEL3u8 RHEL4u4 WindowsPort 0 BGE0 Eth0 Eth2 NETPort 1 BGE1 Eth1 Eth3 NET
OS Nvidia Port 0 Nvidia Port 1Solaris Nge0 Nge1
RHEL3 u8 Eth2 Eth3RHEL4 u4 Eth0 Eth1
Windows 2K3 Net Net1
00 10
1
Lower left Broadcom port isshared with the SP via the
BCM5715 UMP port.Allows the SP to have a
separate MAC and IP addressand does not affect the main
systems use of the port.
(SP Net)
Sun Confidential : Sun/Partners Use Only31
Sun Fire X2100/X2200 M2 Components Tour PCI Express Riser Card
PCI-Express riser card is toolessRiser is removed from the chassis to insert PCI cards.
A dual x8 PCIe riser is standard with optional single x16 PCIe
Riser accommodates Low Profile, Half Length cardsSun Fire X2200 takes 6.5” (160mm) long cards
Cards restricted to 25Watts TOTAL power consumption
Sun Confidential : Sun/Partners Use Only32
Sun Fire X2100 & X2200 M2 Components Tour Power Supplies
Sun Fire X2200 Power Supply
Rated at 450 Watts110/220VAC Single Input Auto Ranging/Sensing
50/60HzTwo Fans
No RedundancyCRU, (Requires a Philips Screwdriver)
Sun Fire X2100 Power Supply
Rated at 340 Watts110/220VAC Single Input Auto Ranging/Sensing
50/60HzSingle Fan
No RedundancyCRU, Requires a Philips Screwdriver
Uses an adapter bracket to fit System Chassis
Sun Confidential : Sun/Partners Use Only33
Sun Fire X2100 & X2200 M2 Components Tour Disk and Optical Drives
Sun Fire X2100 & X2200 M2 hard Disk Drives3.5” SATA Drives, 250GB, 500GB, 750GB, and 1 TB 7200 rpm
3.5” SAS Drives, 146GB, 300 GB 15,000 rpm3.0Gbps for SATA-II and SAS drives
Hot Plug, Easily installed from the front of the system
System requires Blanks if no drive installed in a slotNo Disks in Standard Config
Sun Fire X2100 & X2200 M2 DVD Drives
DVD ROM (Option X8082A)Conventional ATA-133 interface
No Drive in Standard Config
Sun Confidential : Sun/Partners Use Only34
Buffered vs. Unbuffered DIMMsaka. Registered vs. Un-registered– Registered DIMMs have additional registers placed
between the CPUs and DIMMs• Improves signal integrity, allowing longer traces and larger,
more reliable memory subsystems• Up to 4GB per DIMM slot• 8 DIMM slots per CPU• Sun Fire X2200 M2 w/AMD Opteron 2000 Series CPU
– Unbuffered DIMMs do not have these registers• Lower cost and slightly higher performance• Up to 2GB per DIMM slot, 4 DIMM slots• Sun Fire X2100 M2 w/AMD Opteron 1200 Series CPU
Sun Confidential : Sun/Partners Use Only35
Single/Dual/Quad Ranked DIMM LimitsX2200 Limitations• All DIMMS are Ranked, a Rank is a data area created
using some or all of the chips on the DIMM– All ranks are 64 bits wide(+8 bits of ECC)– DIMMS can contain one, two or four Ranks– Each Rank requires a set of control lines– Column Address Strobe (CAS) particularly
• 8 DIMM/Socket systems don't have sufficient CAS lines to satisfy QUAD ranked DIMMS in all slots
– Limits us to 4 Quad Ranked DIMMS– Currently available 4GB DIMMS are all quad ranked– 4GB DIMMS are dual ranked
• If more than 4 Dual/Quad Ranked DIMMS are populated per CPU, require clocking of the DDR2 busses are clocked down from 667 MHz to 533 MHz
Sun Confidential : Sun/Partners Use Only36
Sun Fire X2100/X2200 M2 ComponentsnVidia MCP55Pro Chipset Features Used
MCP55ProMCP55Pro
• Highly integrated Single Chip Core Logic• 1GHz HyperTransport Link x16 up/down
> 8GB/s full speed transfer rates• 6 independent PCI Express Controllers
> Providing 28 PCI-Express Lanes, 20 Used.• 2 separate SATA-II controllers (1.5/3.0 Gbps)• ATA-133 controller for CD/DVD devices• Dual IEEE 802.3 MACs for 10/100/1000BASE-T• 8 USB 2.0 Ports (2 front/4 rear/2 internal SP)• PCI 33MHz/32bit bus for embedded Video device
Sun Confidential : Sun/Partners Use Only37
nVidia Chipset DetailsPCI Express and PCI legacy
MCP55ProMCP55Pro
• 16 PCI Express Lanes > Depending on the Riser configuration used
> Two x8 PCIe slots (Low profile/Half length)> One x16 PCIe slot (Low profile/Half length)
• 4 PCI Express Lanes used internally for the additional Broadcom Dual Port Ethernet Controller
• One PCI 33MHz/32Bit bus dedicated to AST2000 embedded Graphics and Management device
Sun Confidential : Sun/Partners Use Only38
nVidia Chipset DetailsnVidia SATA Controllers
MCP55ProMCP55Pro
• Two independent SATA-II controllers> One controller is dedicated to each drive> Each controller is capable of 1.5 or 3.0Gbps
per direction per channel> Supports Native Command Queueing> Supports Tagged Command Queueing> Supports hot plug (with OS dependencies)
> Support RAID 0 or 1 and JBOD (with OS dependencies)
Sun Confidential : Sun/Partners Use Only39
nVidia SATA Drivers
MCP55ProMCP55Pro
• Solaris> Included in Solaris 10 update 3> Available as a patch for Solaris 10 06/06
• Linux> RHEL3U7 and RHEL4U3 already have nv_sata driver
> More optimized driver provided on the Tools and Drivers CD> Also available for download from nVidia.com
> SuSE 9 SP3 requires drivers from the Tools and Drivers CD• Windows 2003 Server
> Default drivers supported> Drivers provided on the Tools and Drivers CD (also from nVidia)
• VMware ESX 3.x
Sun Confidential : Sun/Partners Use Only40
nVidia Chipset DetailsnVidia Network Controllers
MCP55ProMCP55Pro
• Two independent IEEE 802.3 MACs• Auto-Negotiation and Duplex settings
through an external dual port Marvell 88E1121 PHY
• Supports JUMBO frames (up to 9018 bytes)• 10/100 Mb/s Full or Half Duplex• 1000 Mb/s Full Duplex only• Supports NIC Teaming and failover (with OS
dependencies)
Sun Confidential : Sun/Partners Use Only41
nVidia Network Drivers
MCP55ProMCP55Pro
• Solaris> Included in Solaris 10 update 3> Available as a patch for Update 2(06/06)
• Linux> RHEL3U7 and RHEL4U3, install from Tools and Drivers CD
> Also available for download from nVidia.com> SuSE 9 SP3 requires drivers from the Tools and Drivers CD
• Windows 2003 Server> Drivers provided on the Tools and Drivers CD
> Also available for download from nVidia• VMware ESX 3.X
> Support from VMware post GA
Sun Confidential : Sun/Partners Use Only42
Agenda
• Introduction and Positioning• Server Architecture
> Sun Fire X2200> Sun Fire X2100> Enabling Technologies
• Embedded Light Out Management • Operating Systems• System Options
Sun Confidential : Sun/Partners Use Only43
Embedded LOM Service ProcessorASPEED AST2000
PCI 32bit/33MHz
USB 2.0USB 2.0
BCMNIC 1
Serial
VGAVideo
RearVGA
HD15
SerialPortDB9
UMPPort
Shared SPNIC port
MCP55MCP55
SuperIOLegacyDevice
BIOSFLASHPROM
LPC bus
x4 PCI-E bus (1GB/s)
• Provides all Remote Administration functionality> WebGUI> Remote RKVMS facility> CLI (DMTF SMASH CLP)> SSH or Serial access to CLI> IPMI 2.0> SNMP v1,v2c,v3
• Shares access to the systems Serial port, switch using commands and hot key sequences, > start /SP/AgentInfo/console and the key sequence 'ESC )'
• Shares access to one of the Broadcom NICs using the UMP port feature of the BCM5715 Ethernet Controller.> Has a unique MAC and IP address, different from the OS MAC and IP.
• AST2000 also provides the systems VGA video device using either the AST2000 video driver in Xorg (or the VESA driver), Windows Driver supplied on the Tools and Drivers CD
Sun Confidential : Sun/Partners Use Only44
Embedded LOM Service ProcessorUMP Shared NIC
BCMNIC 1
UMPPort
Shared SPNIC port
x4 PCIe
• AST2000 shares access to the bottom Broadcom ethernet port• The BCM5715 UMP Port acts like a dedicated 10/100 MAC• Providing a Unique MAC and IP address for the UMP port• BMC connects to this UMP MAC at 100Mbps Full Duplex and can inject BMC ethernet traffic
into the main server ethernet stream.• BCM5715 filters and passes on traffic from the main ethernet PHY• Main PHY/MAC can operate at 10/100/1000 and BMC traffic is seamlessly injected
> May Cause issues with critical 'heartbeat' or NIC teaming applications, still in testing
10/10
0/100
0 MAC
Giga
bit P
HY
RXTX
UMP
10/10
0 MAC
TXRX
10/10
0 MAC
RXTX
RX Packets
InternetUMP Command
Processing BMC
TX Packets
PCIe x4 Interface
BCM5715C
UMP
Inter
face
Sun Confidential : Sun/Partners Use Only45
Embedded LOM Service ProcessorInitial Setup• The SP by default 'owns' the serial port• At system power will see the SP boot• Once booted, SP presents a CLI login• Login 'root', default password is 'changeme'• Issue the 'show /SP/AgentInfo/Network' command to determine
SP IP address (DHCP or static)> By default SP will attempt to obtain a DHCP lease, if no lease
is granted after 5 seconds, SP will default to 192.168.1.2/24• Change the IP address using either
> 'set /SP/AgentInfo IpAddress=<new_iP>' for static IP or> 'set /SP/AgentInfo DhcpConfigured=enable' for DHCP IP
• IP changes occur immediately, you may need to reconnect
Sun Confidential : Sun/Partners Use Only46
Embedded LOM Service ProcessorSerial Port Changes• The SP by default 'owns' the serial port• On power application to the server, the
SP can be seen booting on the serial line• Serial port can be configured to show either
the SP CLI or BIOS redirection over serial• Default is selectable from the SP CLI or through the BIOS setup
> SP CLI can be switched to the BIOS/System serial output by > 'start /SP/AgentInfo/console'> Switch back by issuing the key sequence 'ESC' then 'Shift-9'
> Enter the BIOS setup, navigate to the Advanced -> IPMI 2.0 Configuration -> External COM Port screen, change to 'BMC' or 'System'
• NOTE: SP CLI times out after 30 seconds, back to the login prompt
Sun Confidential : Sun/Partners Use Only47
Embedded LOM Service ProcessorWeb GUI
• Access via HTTP via SP IP address• Auto Redirects over HTTPS• User Authenticates by Local or ADS• 8 Users/Roles definable• Requires opening of Firewall Ports
80, 443, 22, 69, for Web GUI and SSH, TFTP (firmware updates)
• RKVMS requires ports 8890, 9000, 9001, 9002, 9003
• Provides a simple GUI• Mini Snapshot of current desktop• Sun Java 1.5+ Browser plugin
required• Simple status screen• Expandable stacked buttons for
functions• Button to Launch RKVMS Java
WebStart Client
• Expand buttons to access next level of function
• Output from function displayed in lower frame
• Three buttons for > System Summary> User Control> Setup
Sun Confidential : Sun/Partners Use Only48
Embedded LOM Service ProcessorWeb GUI Status Page
• Start the RKVMS with the Launch button next to the Snapshot image
• Java WebStart Applet Provides all RKVMS functions
• Requires Sun Java 1.5+ installed on Client system and Browser Plugin Installed
Sun Confidential : Sun/Partners Use Only49
Embedded LOM Service ProcessorWeb GUI RKVMS – System OS booted
• Scalable/Re-sizeable Graphics window
• Up to 1600x1200 resolution
• Live interaction with system Desktop
• Mount virtual DVD/CD/Floppy devices or ISO images as USB 2.0 local devices
Sun Confidential : Sun/Partners Use Only50
Embedded LOM Service ProcessorWeb GUI RKVMS - System In BIOS setup
• Remote Installation• Interact with BIOS
screens• Issue 'Special' key
sequences (Ctrl-Alt-Del, etc)
• Secure (encryption options)
• Quality/bandwidth options
Sun Confidential : Sun/Partners Use Only51
Embedded LOM Service ProcessorDMTF SMASH CLI Examples
Username: rootPassword: ********
Sun(TM) Embedded Lights Out Manager
Copyright 2004-2006 Sun Microsystems, Inc.All rights reserved.
Version 0.90
Hostname: SUNSP00C09F000001
IP address: 10.6.160.113
MAC address: 00:C0:9F:00:00:01/SP ->/SP -> show
/SP Targets: AgentInfo SystemInfo User TftpUpdate
Properties:
Target Commands: show cd
/SP ->
Accessible through Serial line or via SSH to the SP IP address
Power on the system with the commandset /SP/SystemInfo/CtrlInfo PowerCtrl=on
Power the system off with the commandset /SP/SystemInfo/CtrlInfo PowerCtrl=off
Reset the system with the commandset /SP/SystemInfo/CtrlInfo PowerCtrl=reset
Rexamine and set the SP IP address..show /SP/AgentInfoset /SP/AgentInfo/ IpAddress=10.6.160.114set /SP/AgentInfo/ NetMask=255.255.252.0set /SP/AgentInfo/ Gateway=10.6.163.254
Sun Confidential : Sun/Partners Use Only52
Embedded LOM Service ProcessorIPMI 2.0 and SNMP, and CLI PEF
Username: rootPassword: ********
Sun(TM) Embedded Lights Out Manager
Copyright 2004-2006 Sun Microsystems, Inc. All rights reserved.
Version 0.90
Hostname: SUNSP00C09F000001
IP address: 10.6.160.113
MAC address: 00:C0:9F:00:00:01
/SP -> show /SP/AgentInfo/SEL
/SP/AgentInfo/SEL Targets:
Properties:
Target Commands: show
Information ,2006/06/14 11:17:57 ,Processor 0 presence detected
Critical ,2006/06/14 13:52:24 ,CPU1 FAN Tach speed is too low(Value=0.000 RPM: Threshold=78.400 RPM)
Information ,2006/06/14 13:52:26 ,CPU1 FAN Tach back to normal
Critical ,2006/06/14 13:59:17 ,PCI FAN0 not present or stop
Information ,2006/06/14 13:59:20 ,PCI FAN0 back to normal
/SP ->
• Accessible one SP has an IP address• IPMI 2.0 standard reference
http://www.intel.com/design/servers/ipmi/
• IPMI management tool available from http://ipmitool.sourceforge.com/usr/sfw/bin/ipmitool
• SNMP v1, v2c and v3 supported• Sun Fire X2200 Embedded Lights-Out
Manager Administration Guidehttp://docs.sun.com Ref. # 819-6588-xx
Sun Confidential : Sun/Partners Use Only53
Embedded LOM Service ProcessorHints and Tips...
SUNSP0016365B982B login: rootPassword:login[425]: root login on `ttyS1'
Sun(TM) Embedded Lights Out Manager
Copyright 2004-2006 Sun Microsystems, Inc. All rights reserved.
Version 1.1
Hostname: SUNSP0016365B982B
IP address: 10.6.160.115
MAC address: 00:16:36:5B:98:2B
System serial number: 0624QC0017
/SP -> show
/SP Targets: AgentInfo SystemInfo User TftpUpdate
Properties:
Target Commands: show cd reset
/SP ->
Firmware is changing rapidly, make sure you have the latest version before logging bugs.
To recover a lost Embedded LOM Password.> Access the system locally with a screen and keyboard> BIOS Setup -> Advanced -> IPMI 2.0 Configuration -> Reset BMC Root
password
My local mouse is not sync'd with the remote mouse on the Remote Console window> Issue the command xset m 1 1> In the remote system desktop> Use the Ctrl-Alt-M key press to initialize the remote mouse to the top left
of the screen.
Sun Confidential : Sun/Partners Use Only54
Agenda
• Introduction and Positioning• Server Architecture
> Sun Fire X2200> Sun Fire X2100> Enabling Technologies
• Embedded Light Out Management • Operating Systems• System Options
Sun Confidential : Sun/Partners Use Only55
Operating Systems• SuSE SLES 9 SP3
> 64bit supported> Default installs from media> Tools and Drivers CD
updates Video, SATA, Broadcom and nVidia NIC drivers
• Windows 2003 Server> 32 and 64bit> Installs from media> Tools and Drivers CD
updates Video, SATA and NIC drivers
• VMware 3.5> Taurus Support ONLY
Sun Confidential : Sun/Partners Use Only56
Sun Fire Operating Systems
Operating System Dates/CommentsSolaris x64 10u2 and up 64-bitRed Hat Enterprise Linux 3, U8 32-bit, 64-bitRed Hat Enterprise Linux 4, U4 32-bit, 64-bitRed Hat Enterprise Linux 5 32-bit, 64-bitSUSE Linux Enterprise Server 9, SP3 (SLES 9) 64-bitSUSE Linux Enterprise Server 10 (SLES 10) 64-bitWindows Server 2003, Enterprise and Standard Editions, SP1 32-bit, 64-bit
32-bit, 64-bit64-bit
Windows Server 2008, Datacenter, Enterprise and Standard Editions VMware ESX 3.0.2 (Sun Fire X2200 M2 Dual Core only)
Sun Confidential : Sun/Partners Use Only57
Sun Fire Operating SystemsQuad-Core
Operating System Dates/CommentsSolaris x64 10u5 64-bitRed Hat Enterprise Linux 4 U5 32-bit, 64-bitRed Hat Enterprise Linux 5 U1 32-bit, 64-bitSUSE Linux Enterprise Server 9, SP4 (SLES 9) 64-bitSUSE Linux Enterprise Server 10, SP1 (SLES 10) 64-bitWindows Server 2003, Enterprise and Standard Editions, SP1 32-bit, 64-bit
32-bit, 64-bit64-bit
Windows Server 2008, Datacenter, Enterprise and Standard Editions VMware ESX 3.0.2 or ESX 3.5 U1 (Sun Fire X2200 M2 Quad Core only)
Sun Confidential : Sun/Partners Use Only58
Agenda
• Introduction and Positioning• Server Architecture
> Sun Fire X2200> Sun Fire X2100> Enabling Technologies
• Embedded Light Out Management • Operating Systems• System Options
Sun Confidential : Sun/Partners Use Only59
Standard ConfigurationsSun Fire X2200
A85-A-Z1RU ChassisNo AMD Opteron CPU (2 x 1207-pin L1 Sockets)4 x 10/100/1000 Base-T Ethernet PortsIntegrated 2D Graphics Controller (AST2000/VESA)
No Disk DriveNo DVDNo PCI Riser CardA85-JWZ1-H-2GB-JL8
1 x AMD Opteron 2210 (1.8GHz, Dual Core ,95 Watts)2 x 1GB DIMMS (Registered, ECC DDR2-667)I/O Riser Card with 2 x 8-Lane PCI-Express slotsA85-JFZ2-H-4GB-JL8
2 x AMD Opteron 2214 (2.2GHz, Dual Core ,95 Watts)4 x 1GB DIMMS (Registered, ECC DDR2-667)I/O Riser Card with 2 x 8-Lane PCI-Express slotsA85-JGZ2-H-8GB-JL8
Base Config
AST2000 Integrated Service Processor, IPMI2.0, WebGUI, CLI, SNMP
Entry ConfigBase Config A85-A-Z plus....
Mid ConfigBase Config A85-A-Z plus....
Performance ConfigBase Config A85-A-Z plus....
Sun Confidential : Sun/Partners Use Only60
Standard ConfigurationsSun Fire X2100
Part Number DescriptionA84-GQZ1-H-4GB-JL8 Sun Fire X2100 M2 x64 Server: AMD Opteron Model 1222 dual core processor
(3.0GHz/1MB), 4x 1GB unregistered ECC DDR2-667 memory, no Serials ATA drives, no DVD, 1x PSU, Service Processor, 2x 10/100/1000 Ethernet ports, 6x USB 2.0 ports, 1x I/O riser card with 2x PCI-Express x8 slots, no power cords, order Geo-specific x-option. RoHS-5. Standard Configuration
A84-GPZ1-H-2GB-JL8 Sun Fire X2100 M2 x64 Server: AMD Opteron Model 1220 dual core processor (2.8GHz/1MB), 2x 1GB unregistered ECC DDR2-667 memory, no Serials ATA drives, no DVD, 1x PSU, Service Processor, 2x 10/100/1000 Ethernet ports, 6x USB 2.0 ports, 1x I/O riser card with 2x PCI-Express x8 slots, no power cords, order Geo-specific x-option. RoHS-5. Standard Configuration.
A84-GGZ1-H-4GB-JL8 Sun Fire X2100 M2 x64 Server: AMD Opteron Model 1218 dual core processor (2.6GHz/1MB), 4x 1GB unregistered ECC DDR2-667 memory, no Serials ATA drives, no DVD, 1x PSU, Service Processor, 2x 10/100/1000 Ethernet ports, 6x USB 2.0 ports, 1x I/O riser card with 2x PCI-Express x8 slots, no power cords, order Geo-specific x-option. RoHS-5. Standard Configuration.
Sun Confidential : Sun/Partners Use Only61
Standard ConfigurationsSun Fire X2200 - Dual-Core
Part Number DescriptionHigh Performance Dual Core
A85-JGZ2-H-8GC-JL8
Sun Fire X2200 M2 x64 Server: 2x AMD Opteron Model 2218 dual core processor (2.6GHz/1MB/95W), 4x 2GB registered ECC DDR2-667 memory, No HDD, No DVD-ROM, 1x PSU, Service Processor, 4x 10/100/1000 Ethernet ports, 6x USB 2.0 ports, 1x I/O riser card with 2x PCI-Express x8 slots, no power cords, order Geo-specific x-option. RoHS-5. Standard Configuration.
Sun Confidential : Sun/Partners Use Only62
Standard ConfigurationsSun Fire X2200 – Quad-Core Barcelona
Part Number DescriptionA85-FSZ1-H-4GC-JL8 Sun Fire X2200 M2 x64 Server: 1x AMD Opteron Quad Core Model
2356 quad core processor (2.3 GHz, 2MB L3 cache, 75W ACP), 2x 2GB registered ECC DDR2-667 memory, no drives, 1x PSU, Service Processor, 4x 10/100/1000 Ethernet ports, 6x USB 2.0 ports, 1x I/O riser card with 2x PCI-Express x8 slots, no power cords, order Geo-specific x-option. RoHS-5. Standard Configuration.
A85-FFZ1-H-4GC-JL8 Sun Fire X2200 M2 x64 Server: 1x AMD Opteron Quad Core Model 2354 processor (2.2 GHz, 2MB cache, 75 W ACP), 2x 2GB registered ECC DDR2-667 memory, no drives, 1x PSU, Service Processor, 4x 10/100/1000 Ethernet ports, 6x USB 2.0 ports, 1x I/O riser card with 2x PCI-Express x8 slots, no power cords, order Geo-specific x-option. RoHS-5. Standard
Quad Core HE Config A85-SUZ2-H-8GC-JL8
Sun Fire X2200 M2 x64 Server: 2x AMD Opteron Quad Core Model 2347HE processor (1.9 GHz, 2MB cache, 55 W ACP), 4x 2GB registered ECC DDR2-667 memory, no drives, 1x PSU, Service Processor, 4x 10/100/1000 Ethernet ports, 6x USB 2.0 ports, 1x I/O riser card with 2x PCI-Express x8 slots, no power cords, order Geo-specific x-option. RoHS-5. Standard
Sun Confidential : Sun/Partners Use Only63
Sun Fire X2200 Standard Configurations
CPU Clock Speed DDR2 Memory Memory # of SAS HDD RAID HBA DVD-RW PSUs Part NumberSun Fire X2200 Shanghai Standard Configurations2x 2376 2.3GHz 4x 2GB -667 SR 8GB No HDD No No 1 A85-ZSZ2-H-8GC-JL82x 2384 2.7GHz 4x 2GB -667 SR 8GB No HDD No No 1 A85-ZWZ2-H-8GC-JL8
• 800MHz DIMMs being analyzed• EOL – 1GB memory support• More ATO and less standard configurations• Sun Fire X2100 will not support Shangahi
Sun Confidential : Sun/Partners Use Only64
Sun Fire X2200 Upgrade to Shanghai
Upgrade OptionsCPU X-Option ATO Date
AMD Opteron 2376 (2.3GHz/512KB, 75W ACP Quad Core) X5334A 5334A Dec-2008AMD Opteron 2384 (2.7GHz/512KB, 75W ACP Quad Core) X5335A 5335A Dec-2008
New 4GB Memory X-Option ATO Date8GB DDR2-667 Registered ECC Memory (2x4GB) X4087A 4087A Dec-2008
• http://docs.sun.com/source/820-3270-12/index.html
• Download the Sun Fire X2200 M2 Server Tools and Drivers CD v2.0 (or later) ISO image
• Record Current BIOS settings (ELOM)
• Upgrade processor to Shanghai
• Is BIOS 3D08?> Then Upgrade 512K BIOS PROM to 1M> Remove the Firmware PROM and install new PROM> Special PLCC extraction tool is necessary
• Upgrade the SP/BMC Firmware with Tools and Driver CD
• Check BIOS and upgrade if necessary
• Micron memory being phased out – field notice
Sun Confidential : Sun/Partners Use Only65
Add-in Card Options
X-Option ATO CRS DescriptionSG-XPCIE2FC-QF4 SG-PCIE2FC-QF4SG-XPCIE1FC-QF4 SG-PCIE1FC-QF4 SG-PCIE1FC-QF4SG-XPCIE2FC-EM4 SG-PCIE2FC-EM4 SG-PCIE2FC-EM4SG-XPCIE1FC-EM4 SG-PCIE1FC-EM4 SG-PCIE1FC-EM4X7280A-2
SG-XPCIE2SCSIU320Z SG-PCIE2SCSIU320Z Sun PCI-E Ultra320 SCSI 2-port HBA. RoHS-6
X7281A-2X1106A-Z n/a X1106A-Z Single port Sun 10 Gigabit Ethernet Networking Card with fixed transceiver (Intel) X1107A-Z n/a X1107A-Z Dual port Sun 10 Gigabit Ethernet Networking Card with fixed transceiver (Intel) X1236A-Z 1236A-Z 1236A-ZSG-XPCIE4SAS3-Z SG-PCIE4SAS3-Z LSI Logic SAS3041E-R, PCI Express, 4-port 3Gb/s (SAS) HBA
SG-PCIE2FC-QF4 Sun StorEdge 4 GB Dual Port Fibre Channel PCI-Express Card (Qlogic). RoHS-6.Sun StorEdge 4 GB Single Port Fibre Channel PCI-Express Card (Qlogic). RoHS-6.Sun StorEdge 4 GB Dual Port Fibre Channel PCI-Express Card (Emulex). RoHS-6.Sun StorEdge 4 GB Single Port Fibre Channel PCI-Express Card (Emulex). RoHS-6.
7280A-2 7280A-2 Sun PCI-E Low profile Dual GigE (Copper) UTP, low profile bracket on board. Standard bracket included in X-option. ROHS-6.
SG-PCIE2SCSIU320Z 7281A-2 7281A-2 Sun PCI-E Low-Profile Dual GigE (Fiber) MMF, low profile bracket on board. Standard
bracket included in X-option. RoHS-6.
Infiniband PCI-Express Card. RoHS-6. SG-PCIE4SAS3-Z
List subject to change and not final
Sun Fire X2100/X2200 M2 TechnicalProduct Training Presentation
Ronald GrahamSystems Group Technical MarketingSun Microsystems