144
Fiber-optic sensors and fibers Fits flexibly into the narrowest corners Product inFormation We can help you to quickly target the product that best matches your application. Select the application description on the basis of the challenge posed, industrial sector, or product group. Go directly to the operating instruc- tions, technical information, and other literature on all aspects of SICK products. www.mysick.com – Your quick access to maximum efficiency these and other Finders at www.mysick.com Find out prices and availability Determine the price and possible delivery date of your desired product simply and quickly. request or view a quote You can have a quote generated online here. Every quote is confirmed to you via e-mail. order online You can go through the ordering process in just a few steps. clearly structured available 24 hours a day Safe Efficiency – with SicK e-commerce tools

Sick Fibre Optic Sensors and Fibers

Embed Size (px)

DESCRIPTION

[email protected]/ +44 (0) 191 490 1547 Please contact us today to request a quote.

Citation preview

Page 1: Sick Fibre Optic Sensors and Fibers

SICK AG | Waldkirch | Germany | www.sick.com

Fiber-optic sensors and fibers

Fits flexibly into the narrowest corners

Pr

od

uc

t in

Fo

rm

ati

on

Fibe

r-opt

ic s

enso

rs a

nd fi

bers

| P

rodu

ct in

form

atio

n

We can help you to quickly target the product that best matches your application.

Select the application description on the basis of the challenge posed, industrial sector, or product group.

Go directly to the operating instruc-tions, technical information, and other literature on all aspects of SICK products.

www.mysick.com – Your quick access to maximum efficiency

these and other Finders at www.mysick.com

Find out prices and availabilityDetermine the price and possible delivery date of your desired product simply and quickly.

request or view a quoteYou can have a quote generated online here. Every quote is confirmed to you via e-mail.

order onlineYou can go through the ordering process in just a few steps.

• clearly structured • available 24 hours a day • Safe

Efficiency – with SicK e-commerce tools

8014

999/

2012

-05-

31 ∙

MK

(201

2-05

) ∙ W

B US

mod

int3

7

Leading technologies

With a staff of more than 5,000 and over 50 subsidiaries and representa-tions worldwide, SICK is one of the leading and most successful manufac-turers of sensor technology. The power of innovation and solution competency have made SICK the global market leader. No matter what the project and industry may be, talking with an expert from SICK will provide you with an ideal basis for your plans – there is no need to settle for anything less than the best.

Unique product range

• Non-contact detecting, counting, classifying, positioning and measur-ing of any type of object or media

• Accident and operator protection with sensors, safety software and services

• Automatic identification with bar code and RFID readers

• Laser measurement technology for detecting the volume, position and contour of people and objects

• Complete system solutions for analy-sis and flow measurement of gases and liquids

Comprehensive services

• SICK LifeTime Services – for safety and productivity

• Application centers in Europe, Asia and North America for the develop-ment of system solutions under real-world conditions

• E-Business Partner Portal www.mysick.com – price and availabi-lity of products, requests for quotation and online orders

SicK at a glance

Worldwide presence with subsidiaries in the following countries:

australia Belgium/Luxembourg Brasil ceská republika canada china danmark deutschland España France Great Britain india israel italia Japan

méxico nederland norge Österreich Polska românia russia Schweiz Singapore Slovenija South africa South Korea Suomi Sverige taiwan türkiye united arab Emirates uSa

Please find detailed addresses and additional representatives and agencies in all major industrial nations at www.sick.com

Page 2: Sick Fibre Optic Sensors and Fibers

1 4 3

M6

300°C

2

icon overview

Systems

design

Proximity system Through-beam system

Threaded sleeve

Smooth sleeve

90° deflection

Flat design

Flexible fibers

Long end sleeve

Fields of application

Area detection

Heat-resistant

Liquid level

Robotics

Retro-reflectiveOil/chemical resistant

LCDs/transparent objects/semiconductors

3 steps to finding suitable fibers

additional product information

www.sick.com/fiber

1. Icon overview

Select the design or application for the fibers. The applicable characteristics are highlighted in color in the selection table. Page 6

You can find further technical data about fibers along with dimensional drawings and 3D CAD files in the product finder for fibers at www.sick.com.

2. Fiber categories

Select the fibers that are suitable for your application.Page 16

3. Fiber-optic sensors

Select an amplifier. Page 86

General information www.mysick.com – Your quick access to maximum efficiency

Search online quickly and safely with the SicK „Finders“

Efficiency – with SicK e-commerce tools

Find out prices and availabilityDetermine the price and possible delivery date of your desired product simply and quickly at any time.

request or view a quoteYou can have a quote generated online here.Every quote is confirmed to you via e-mail.

order onlineYou can go through the ordering process in just a few steps.

Product Finder: We can help you to quickly target the pro-duct that best matches your application.

applications Finder: Select the application description on the basis of the challenge posed, industrial sector, or pro-duct group.

Literature Finder: Go directly to the operating instructions, technical information, and other literature on all aspects of SICK products.

these and other Finders at www.mysick.com

ProductApplicationsLiteratureServiceConnection diagramAccessoriesSpare partSoftware

clearly structured: You can find everything you need for your sensor planning under the menu items Pro-ducts, Information, and My Account.

available 24 hours a day: Regard-less of where you are in the world or what you would like to know – everything is just a click away at www.mysick.com.

Safe: Your data is password-pro-tected and only visible to you. With the individual user management, you define who can see what data and who can execute what actions.

8014999/2012-05Subject to change without notice

F i B E r - o P t i c P h o t o E L E c t r i c S E n S o r S | S i c K F i B E r - o P t i c P h o t o E L E c t r i c S E n S o r S | S i c K8014999/2012-05Subject to change without notice

B

8014999/2012-05Subject to change without notice

6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

selection guides Proximity systems

Model name Design Application page

LL3-DB01 M6

300°C

16

LL3-DB01-3 M6

300°C

16

LL3-DB01-10 M6

300°C

17

LL3-DB01-30 M6

300°C

17

LL3-DB02 M6

300°C

48

LL3-DB03 M6

300°C

17

LL3-DB04 M4

300°C

17

LL3-DB05 M6

300°C

48

LL3-DB06 M6

300°C

49

LL3-DB07 M3

300°C

17

LL3-DB08 M6

300°C

49

LL3-DB09 M6

300°C

28

LL3-DB10 M6

300°C

24

LL3-DC03 M6

300°C

34/70

LL3-DC04 M6

300°C

34/40/71/74

LL3-DC05 M6

300°C

35/71

LL3-DC06 M6

300°C

35/40/71/74

LL3-DC07 M6

300°C

35/71

LL3-DC08 M6

300°C

35/71

LL3-DC09 M6

300°C

35/71

LL3-DC38 M6

300°C

35/71

LL3-DC39 M6

300°C

35/71

LL3-DC47 M6

300°C

35/41

LL3-DC57 M6

300°C

35/41

Fiber-optic proximity systems

B

8014999/2012-05Subject to change without notice

7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

selection guidesProximity systems

Model name Design Application page

LL3-DE01 M6

300°C

36/41

LL3-DE02 M6

300°C

36/41

LL3-DE03 M6

300°C

36/41

LL3-DE04 M6

300°C

36/41

LL3-DF02-S01 M6

300°C

66

LL3-DF04 M6

300°C

67

LL3-DF05 M6

300°C

67

LL3-DF07 M6

300°C

67

LL3-DH01 M6

180°C

17/58

LL3-DH01-03 M6

180°C

17/58

LL3-DH02 M6

300°C

17/59

LL3-DH03 M6

350°C

59

LL3-DH04 M6

350°C

49/59

LL3-DH05 M6

350°C

49/59

LL3-DH06 M6

300°C

36/59/71

LL3-DH07 M6

200°C

59

LL3-DH08 M6

180°C

36/59/72

LL3-DH09 M6

130°C

59

LL3-DH10 M6

250°C

36/59/72

LL3-DH11 M6

250°C

36/60/72

LL3-DJ01 M3

300°C

17

LL3-DJ02 M6

300°C

18

LL3-DK04 M6

300°C

24

LL3-DK06 M6

300°C

18

LL3-DK21 M3

300°C

18

C

M6

8014999/2012-05Subject to change without notice

1 6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

threaded sleeve Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

threaded sleeves

Fibers with thread are easy to mount, e.g., on a mounting bracket. An even greater sensing range can be achieved with a tip adapter, which can be optionally screwed on to some models.

The LL3-TV05/06/07 and LL3-DV05/06/07 90° models with hexagonal head, for example, are ideal for space-saving mounting. These are also available as highly-flexible and heat-resistant fibers.

Fiber-optic proximity systems

Model name Minimum bend radius

Minimum object size*

tempera-ture

Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DB01 M6

25 mm Ø 0.015 mm-40 °C

–+70 °C

2 m90 1) 160 6)

5308074

280 2) 62 7)

500 3) 37 8)

900 4)

1350 5)

LL3-DB01-3 M6

25 mm Ø 0.015 mm-40 °C

–+70 °C

3 m90 1) 160 6)

5322552

280 2) 62 7)

500 3) 37 8)

900 4)

1350 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Axial outlet Fibers with hexagon head for space-saving installation

C

8014999/2012-05Subject to change without notice

1 7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

threaded sleeveProximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DB01-10M6

25 mm Ø 0.015 mm-40 °C

–+70 °C

10 m50 1) 90 6)

5308075

140 2) 27 7)

250 3) 32 8)

500 4)

750 5)

LL3-DB01-30M6

25 mm Ø 0.015 mm-40 °C

–+70 °C

30 m35 1) 63 6)

5324662

98 2) 18 7)

175 3) 25 8)

350 4)

525 5)

LL3-DB03 M6

25 mm Ø 0.015 mm-40 °C

–+70 °C

2 m90 1) 160 6)

5313021

300 2) 62 7)

500 3) 37 8)

900 4)

1350 5)

LL3-DB04 M4

25 mm Ø 0.015 mm-40 °C

–+70 °C

2 m90 1) 90 6)

5325990

280 2) 55 7)

500 3) 50 8)

900 4)

1350 5)

LL3-DB07 M3

25 mm Ø 0.02 mm-40 °C

–+60 °C

2 m27 1) 65 6)

5325988

88 2) 30 7)

165 3) 20 8)

330 4)

350 5)

LL3-DH01 M6

180°C

35 mm Ø 0.015 mm-40 °C

–+180 °C

2 m120 1) 220 6)

5308091

350 2) 95 7)

600 3) 45 8)

980 4)

1500 5)

LL3-DH01-03M6

180°C

35 mm Ø 0.015 mm-40 °C

–+180 °C

3 m100 1) 150 6)

5321260

300 2) 85 7)

500 3) 40 8)

850 4)

1400 5)

LL3-DH02 M6

100°C

25 mm Ø 0.015 mm-40 °C

–+100 °C

2 m70 1) 125 6)

5308092

230 2) 45 7)

350 3) 8 8)

600 4)

1000 5)

LL3-DJ01 M3

10 mm Ø 0.02 mm-40 °C

–+60 °C

1 m

14 1) 60 6)

5325989

49 2) 27 7)

99 3) 17 8)

190 4)

210 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

E

8014999/2012-05Subject to change without notice

8 6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Amplifiers

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Fits flexibly into the narrowest corners

When installation space is extremely limited or the objects to be detected are tiny, fiber-optic sensors are the ideal solution. If it is necessary for even higher requirements to be fulfilled, such as sensing range, temperature resistance, material durability or a flexible mounting process, the intelligent combination of sensors and fibers can provide the perfect solution. A wide range of fibers with application-specific optical heads ensure that every need is met.

Your benefits • Reliable and accurate detection

of the smallest objects thanks to innovative, microcontroller-supported electronics

• EMC, high temperature tolerance and resistance to chemicals, as the evaluation electronics are mounted separately from the fiber-optic head

• Space-saving mounting even in confined spaces

• Multiple setting options provide solutions for practically any application

• Lightweight, suitable for use on a robot arm

• Universal application possibilities due to wide range of fibers

E

8014999/2012-05Subject to change without notice

8 7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Amplifiers

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Fiber-optic sensors and fibers

product family overview 88

Wll170-2Versatility for standard applications

90

Wll180tA global leader when it comes to sensing range and performance

96

QuickFind3QuickFind2QuickFind1

Page 3: Sick Fibre Optic Sensors and Fibers

A

B

C

D

E

F

G

H

8014999/2012-05Subject to change without notice

3F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

table of contents

General information

QuickFind

www.sick.com2

overview/selection guides

Icon overviewSystems/design/fields of application

Selection tables

4

6

Fibers 14

tip adapters 80

AmplifiersWLL170-2

WLL180T86

Appendix

Mounting systems/connectors 104

Fibers dimensional drawings 106

Index by part no.

Index by model name

138

140

QuickFind1

QuickFind2

QuickFind3

Page 4: Sick Fibre Optic Sensors and Fibers

M6

B

8014999/2012-05Subject to change without notice

4 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

overview/selection guides System and design pictograms

systems

Design

• Sender and receiver fibers are enclosed together or combined in a single sensor head

• Recognition of object by detecting the light beam reflected from the object

• Optical axis does not need to be adjusted

• Sender and receiver fibers are mounted separately• Detection of object by moving

the optical axis between sender and receiver• Very large sensing ranges• For accurate positioning

• Quick and easy mounting• Models with hexagonal flange for trouble-free

mounting with only one nut• Optional tip adapter for a larger detection distance

and detection of small objects

• For installation in areas with limited space• The smooth sleeve is simply secured with a setscrew

• Space-saving installation• 90 degree sensing tips for detection of objects

in tight areas

• Easy mounting• Flush mounting in a single slot• Detection of objects in the background are minimized

• Easy installation around small corners• 1 mm bend radius

• Sensor tip can be positioned close to the object• Flexible end sleeves are available• Fits in tight spaces

• Reflective or transparent objects can be detected• Easy mounting• Ideal for color and position markings

• Stable measuring position• Optically opaque objects can be detected

regardless of their shape, color or material• Strong light beam

Proximity system

Through-beam system

Threaded sleeve

Smooth sleeve

90° deflection

Flat design

Flexible fibers

Long end sleeve

Page 5: Sick Fibre Optic Sensors and Fibers

300°C

B

8014999/2012-05Subject to change without notice

5F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

overview/selection guidesFields of application pictograms

Fields of application

• Detection of objects with different shapes• Detection of moving and free-falling objects• Leading edge detection

• Heat-resistant plastic and glass fibers• Glass fibers with metallic sheath• Suitable for high-temperature applications

up to +350 °C

• Fibers for tube mounting and for immersion into liquids

• Models for immersion are made of PTFE and are suitable for the food industry

• Leakage detection

• Ideal for repeated bending• Presence detection in the gripper

• Detection of transparent objects• Integrated polarizing filter for safe detection

of shiny/reflective objects

• PTFE sheath• Resistant to a wide range of chemicals

and cleaning agents• Suitable for the food and beverage industry

• Detection of glass substrates• Detection of solar wafers• Indexing, e.g., in FOUP (Front Opening Unified Pod)

Heat-resistant

Area detection

Liquid level

Robotics

Retro-reflective

Oil and chemical resistant

LCDs/transparent objects/semiconductors

Page 6: Sick Fibre Optic Sensors and Fibers

B

8014999/2012-05Subject to change without notice

6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

selection guides Proximity systems

Model name Design Application page

LL3-DB01 M6

300°C

16

LL3-DB01-3 M6

300°C

16

LL3-DB01-10 M6

300°C

17

LL3-DB01-30 M6

300°C

17

LL3-DB02 M6

300°C

48

LL3-DB03 M6

300°C

17

LL3-DB04 M4

300°C

17

LL3-DB05 M6

300°C

48

LL3-DB06 M6

300°C

49

LL3-DB07 M3

300°C

17

LL3-DB08 M6

300°C

49

LL3-DB09 M6

300°C

28

LL3-DB10 M6

300°C

24

LL3-DC03 M6

300°C

34/70

LL3-DC04 M6

300°C

34/40/71/74

LL3-DC05 M6

300°C

35/71

LL3-DC06 M6

300°C

35/40/71/74

LL3-DC07 M6

300°C

35/71

LL3-DC08 M6

300°C

35/71

LL3-DC09 M6

300°C

35/71

LL3-DC38 M6

300°C

35/71

LL3-DC39 M6

300°C

35/71

LL3-DC47 M6

300°C

35/41

LL3-DC57 M6

300°C

35/41

Fiber-optic proximity systems

Page 7: Sick Fibre Optic Sensors and Fibers

B

8014999/2012-05Subject to change without notice

7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

selection guidesProximity systems

Model name Design Application page

LL3-DE01 M6

300°C

36/41

LL3-DE02 M6

300°C

36/41

LL3-DE03 M6

300°C

36/41

LL3-DE04 M6

300°C

36/41

LL3-DF02-S01 M6

300°C

66

LL3-DF04 M6

300°C

67

LL3-DF05 M6

300°C

67

LL3-DF07 M6

300°C

67

LL3-DH01 M6

180°C

17/58

LL3-DH01-03 M6180°C

17/58

LL3-DH02 M6

300°C

17/59

LL3-DH03 M6

350°C

59

LL3-DH04 M6

350°C

49/59

LL3-DH05 M6

350°C

49/59

LL3-DH06 M6

300°C

36/59/71

LL3-DH07 M6

200°C

59

LL3-DH08 M6

180°C

36/59/72

LL3-DH09 M6

130°C

59

LL3-DH10 M6

250°C

36/59/72

LL3-DH11 M6

250°C

36/60/72

LL3-DJ01 M3

300°C

17

LL3-DJ02 M6

300°C

18

LL3-DK04 M6

300°C

24

LL3-DK06 M6

300°C

18

LL3-DK21 M3

300°C

18

Page 8: Sick Fibre Optic Sensors and Fibers

B

8014999/2012-05Subject to change without notice

8 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Design Application page

LL3-DK33 M6

300°C

28/49

LL3-DK43 M6

300°C

49

LL3-DK4Z M6

300°C

25/41

LL3-DK63Z M6

300°C

41/49

LL3-DK66 M4

300°C

18/41

LL3-DK67 M6

300°C

18/42

LL3-DM01 M4

300°C

18

LL3-DM02 M4

300°C

18

LL3-DM03 M6

300°C

49

LL3-DP01 M6

300°C

25

LL3-DR01 M6

300°C

18/42/75

LL3-DR02 M3

300°C

18/42/75

LL3-DR03 M6

300°C

25/42/75

LL3-DR04 M6

300°C

25/42/75

LL3-DR05 M6

300°C

25/75

LL3-DR06 M4

300°C

19/42/75

LL3-DR07 M6

300°C

49

LL3-DR08 M3

300°C

19/75

LL3-DR09 M6

300°C

36/42/72

LL3-DR10 M6

300°C

50

LL3-DR11 M6

300°C

25

LL3-DR12 M6

300°C

25/29/42

LL3-DS06 M3

300°C

19

LL3-DT01 M3

300°C

19

LL3-DT01-05 M3

300°C

19

selection guide Proximity systems

Page 9: Sick Fibre Optic Sensors and Fibers

B

8014999/2012-05Subject to change without notice

9F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

selection guideProximity systems

Model name Design Application page

LL3-DT02 M6

300°C

42/50/75

LL3-DT03 M6

300°C

25

LL3-DT04 M6

300°C

43/50/75

LL3-DT05 M6

300°C

50

LL3-DV01 M6

300°C

29/50

LL3-DV02 M6

300°C

29/50

LL3-DV03 M6

300°C

29/50

LL3-DV05 M6

300°C

19/29

LL3-DV06 M6

105°C

19/29/60

LL3-DV07 M6300°C

19/29/43

LL3-DW01 M6

200°C

20/60/67

LL3-DW01-2 M6

200°C

20/60/67

LL3-DW02 M6

300°C

67

LL3-DYO1 M6

300°C

64

LL3-DZ01 M6

300°C

54

LL3-DZ02 M6

300°C

55

LL3-DZ03 M6

300°C

55

LL3-RB01 M6

300°C

78

LL3-RB02 M6

300°C

78

LL3-RG01 M6

300°C

79

LL3-RR01 M6

300°C

79

Page 10: Sick Fibre Optic Sensors and Fibers

B

8014999/2012-05Subject to change without notice

1 0 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

selection guide Through-beam systems

Model name Design Application page

LL3-TB01 M4

300°C

21

LL3-TB01-10 M4

300°C

21

LL3-TB01-30 M4

300°C

21

LL3-TB02 M4

300°C

21

LL3-TB03 M6

300°C

51

LL3-TB05 M6

300°C

51

LL3-TB06 M6

300°C

30

LL3-TB07 M6

300°C

26

LL3-TB08 M14

300°C

21

LL3-TE01 M6

300°C

37/43

LL3-TE02 M6

300°C

37/43

LL3-TE03 M6

300°C

37/43

LL3-TE04 M6

300°C

37/43

LL3-TE05 M6

300°C

37/44

LL3-TF01 M6

300°C

68

LL3-TG01 M6

300°C

73

LL3-TG02 M6

300°C

30/44/73

LL3-TG03 M6

300°C

73

LL3-TG04 M6

300°C

73

LL3-TG05 M6

300°C

26/30/44

LL3-TH01 M4

300°C

21/61

LL3-TH02 M4

180°C

21/61

LL3-TH06 M6

300°C

26/30

LL3-TH07 M6

200°C

30/61

Fiber-optic through-beam systems

Page 11: Sick Fibre Optic Sensors and Fibers

B

8014999/2012-05Subject to change without notice

1 1F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

selection guideThrough-beam systems

Model name Design Application page

LL3-TH08 M6

350°C

61

LL3-TH09 M6

350°C

61

LL3-TH10 M6

200°C

61

LL3-TH11 M6

200°C

61

LL3-TH12 M6

200°C

61

LL3-TH13 M6

200°C

62

LL3-TH14 M6

200°C

62

LL3-TH15 M6

200°C

30/62

LL3-TH16 M6

200°C

30/62

LL3-TH17 M6130°C

62

LL3-TJ01 M4

300°C

21

LL3-TK05 M6

300°C

26/44

LL3-TK16 M6

300°C

30/51

LL3-TK77 M4

300°C

22/44

LL3-TM01 M3

300°C

22

LL3-TM02 M3

300°C

22

LL3-TM03 M6

300°C

26

LL3-TP01 M6

300°C

51

LL3-TR01 M4

300°C

22/44/76

LL3-TR01-05 M4

300°C

22/44/76

LL3-TR02 M3

300°C

22/44/76

LL3-TR03 M6

300°C

26/44/76

LL3-TR03-2 M6

300°C

26/45/76

LL3-TR04 M6

300°C

26/45/76

LL3-TR05 M6

300°C

37/45/76

Page 12: Sick Fibre Optic Sensors and Fibers

B

8014999/2012-05Subject to change without notice

1 2 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

selection guides Through-beam systems

Model name Design Application page

LL3-TR06 M6

300°C

37/45/76

LL3-TR08 M6

300°C

31/45/73

LL3-TR09 M6

300°C

31/45/73

LL3-TR10 M6

300°C

27/45

LL3-TR11 M6

300°C

37/45

LL3-TR12 M6

300°C

38/45

LL3-TR13 M6

300°C

38/46

LL3-TS07 M6

300°C

27

LL3-TS08 M6

300°C

31/51

LL3-TS10 M6

300°C

55

LL3-TS12 M6

300°C

31/51

LL3-TS14 M6

300°C

55

LL3-TS22 M6

300°C

31/73

LL3-TS22M M6

105°C

31/62

LL3-TS22V M6

300°C

27/31/46

LL3-TS40 M6

300°C

55

LL3-TT01 M6

300°C

51

LL3-TV01 M6

300°C

31/51

LL3-TV02 M6

300°C

32/52

LL3-TV04 M6

300°C

32/52

LL3-TV05 M4

300°C

22/32

LL3-TV06 M4

105°C

22/32/62

LL3-TV07 M4

300°C

22/32/46

LL3-TV08 M6

300°C

27/32

LL3-TW01 M4

200°C

23/62/68

Page 13: Sick Fibre Optic Sensors and Fibers

B

8014999/2012-05Subject to change without notice

1 3F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

selection guidesThrough-beam systems

Model name Design Application page

LL3-TW01-2 M4

200°C

23/62/68

LL3-TX01 M12

300°C

23

LL3-TY01 M6

300°C

65

LL3-TY02 M6

300°C

32/65

LL3-TY03 M6

300°C

32/65

LL3-TY04 M6

300°C

65

LL3-TY05 M6

300°C

65

LL3-TZ05 M6

300°C

55

LL3-TZ06 M6

300°C

55

LL3-TZ09 M6300°C

46/56

LL3-TZ10 M6

300°C

56

Page 14: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

1 4 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Fibers Content overview

The starting point for finding the ideal sensor solution for your application is choosing the right fiber and specific design. The wide variety of plastic or glass fibers from SICK provide optimum automation solutions. This is particularly true when it comes to solutions that require flexible installation, the ability to operate in high temperatures, or that require a high degree of durability. While plastic fibers are characterized, among other things, by the smallest of bend radii and maximum flexibility, and the ability to be shortened, lass fibers are more chemically resistant and suitable for a higher temperature range. The wide variety of end sleeve options or individual special sleeves can handle any installation requirement. Depending on the application, the protective cladding of the fibers can be made from plastic, metal, or PTFE for exposure to aggressive chemicals.

it's the tip that makes the difference

Fibers –fit flexibly into the narrowest corners

Page 15: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

1 5F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

FibersContent overview

Design Application

M6 threaded sleeves 16

smooth sleeves 24

90° deflection 28

Flat design 34

Flexible fibers 40

long end sleeves 48

Area detection 54

300°C

Heat-resistant 58

oil/chemical resistant 64

liquid level 66

lCDs/transparent objects/semiconductors

70

robotics 74

retro-reflective 78

Page 16: Sick Fibre Optic Sensors and Fibers

C

M6

8014999/2012-05Subject to change without notice

1 6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

threaded sleeve Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

threaded sleeves

Fibers with thread are easy to mount, e.g., on a mounting bracket. An even greater sensing range can be achieved with a tip adapter, which can be optionally screwed on to some models.

The LL3-TV05/06/07 and LL3-DV05/06/07 90° models with hexagonal head, for example, are ideal for space-saving mounting. These are also available as highly-flexible and heat-resistant fibers.

Fiber-optic proximity systems

Model name Minimum bend radius

Minimum object size*

tempera-ture

Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DB01 M6

25 mm Ø 0.015 mm-40 °C

–+70 °C

2 m90 1) 160 6)

5308074

280 2) 62 7)

500 3) 37 8)

900 4)

1350 5)

LL3-DB01-3 M6

25 mm Ø 0.015 mm-40 °C

–+70 °C

3 m90 1) 160 6)

5322552

280 2) 62 7)

500 3) 37 8)

900 4)

1350 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Axial outlet Fibers with hexagon head for space-saving installation

Page 17: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

1 7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

threaded sleeveProximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DB01-10M6

25 mm Ø 0.015 mm-40 °C

–+70 °C

10 m50 1) 90 6)

5308075

140 2) 27 7)

250 3) 32 8)

500 4)

750 5)

LL3-DB01-30M6

25 mm Ø 0.015 mm-40 °C

–+70 °C

30 m35 1) 63 6)

5324662

98 2) 18 7)

175 3) 25 8)

350 4)

525 5)

LL3-DB03 M6

25 mm Ø 0.015 mm-40 °C

–+70 °C

2 m90 1) 160 6)

5313021

300 2) 62 7)

500 3) 37 8)

900 4)

1350 5)

LL3-DB04 M4

25 mm Ø 0.015 mm-40 °C

–+70 °C

2 m90 1) 90 6)

5325990

280 2) 55 7)

500 3) 50 8)

900 4)

1350 5)

LL3-DB07 M3

25 mm Ø 0.02 mm-40 °C

–+60 °C

2 m27 1) 65 6)

5325988

88 2) 30 7)

165 3) 20 8)

330 4)

350 5)

LL3-DH01 M6

180°C

35 mm Ø 0.015 mm-40 °C

–+180 °C

2 m120 1) 220 6)

5308091

350 2) 95 7)

600 3) 45 8)

980 4)

1500 5)

LL3-DH01-03M6

180°C

35 mm Ø 0.015 mm-40 °C

–+180 °C

3 m100 1) 150 6)

5321260

300 2) 85 7)

500 3) 40 8)

850 4)

1400 5)

LL3-DH02 M6

100°C

25 mm Ø 0.015 mm-40 °C

–+100 °C

2 m70 1) 125 6)

5308092

230 2) 45 7)

350 3) 8 8)

600 4)

1000 5)

LL3-DJ01 M3

10 mm Ø 0.02 mm-40 °C

–+60 °C

1 m

14 1) 60 6)

5325989

49 2) 27 7)

99 3) 17 8)

190 4)

210 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 18: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

1 8 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

threaded sleeves Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DJ02 M6

10 mm Ø 0.02 mm-40 °C

–+70 °C

1 m

38 1) 110 6)

5325992

120 2) 50 7)

230 3) 30 8)

460 4)

490 5)

LL3-DK06 M6

25 mm Ø 0.015 mm-40 °C

–+70 °C

2 m100 1) 165 6)

5313019

300 2) 65 7)

500 3) 37 8)

900 4)

1400 5)

LL3-DK21M3

Suitable for tip adapters

15 mm Ø 0.015 mm-40 °C

–+70 °C

0.5 m

14 1) 17 6)

5313023

45 2) 7 7)

75 3) 3 8)

135 4)

200 5)

LL3-DK66 M4

2 mm Ø 0.015 mm-40 °C

–+70 °C

2 m90 1) 115 6)

5313024

300 2) 47 7)

500 3) 27 8)

900 4)

1400 5)

LL3-DK67 M6

2 mm Ø 0.015 mm-40 °C

–+70 °C

2 m90 1) 115 6)

5313025

300 2) 47 7)

500 3) 27 8)

900 4)

1400 5)

LL3-DM01 M4

25 mm Ø 0.015 mm-40 °C

–+70 °C

2 m75 1) 165 6)

5308071

255 2) 65 7)

420 3) 37 8)

800 4)

1300 5)

LL3-DM02 M4

Suitable for tip adapters

15 mm Ø 0.015 mm-40 °C

–+70 °C

2 m40 1) 72 6)

5308077

130 2) 22 7)

200 3) 11 8)

350 4)

600 5)

LL3-DR01 M6

4 mm Ø 0.015 mm-40 °C

–+70 °C

2 m90 1) 135 6)

5308078

280 2) 50 7)

450 3) 20 8)

880 4)

1350 5)

LL3-DR02M3

4 mm Ø 0.015 mm-40 °C

–+70 °C

1 m18 1) 22 6)

5308079

50 2) 9 7)

90 3) 3 8)

200 4)

370 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 19: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

1 9F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

threaded sleevesProximity systems

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DR06 M4

4 mm Ø 0.015 mm-40 °C

–+70 °C

2 m18 1) 37 6)

5308082

60 2) 11 7)

100 3) 5 8)

220 4)

360 5)

LL3-DR08 M3

4 mm Ø 0.02 mm-40 °C

–+70 °C

2 m8 1) 22 6)

5326037

25 2) 9 7)

46 3) 6 8)

90 4)

98 5)

LL3-DS06 M3

15 mm Ø 0.015 mm-40 °C

–+70 °C

2 m18 1) 47 6)

5308073

55 2) 17 7)

95 3) 7 8)

190 4)

360 5)

LL3-DT01 M3

Suitable for tip adapters

15 mm Ø 0.015 mm-40 °C

–+70 °C

2 m40 1) 75 6)

5308076

130 2) 22 7)

200 3) 11 8)

350 4)

600 5)

LL3-DT01-05 M3

Suitable for tip adapters

15 mm Ø 0.015 mm-40 °C

–+70 °C

5 m30 1) 45 6)

5309087

100 2) 18 7)

150 3) 9 8)

300 4)

500 5)

LL3-DV05 M6

25 mm Ø 0.015 mm-40 °C

–+70 °C

2 m25 1) 47 6)

5322549

110 2) 17 7)

185 3) 17 8)

400 4)

650 5)

LL3-DV06 M6

105°C

25 mm Ø 0.015 mm-40 °C

–+105 °C

2 m30 1) 47 6)

5322550

130 2) 12 7)

210 3) 12 8)

450 4)

800 5)

LL3-DV07 M6

2 mm Ø 0.015 mm-40 °C

–+70 °C

2 m20 1) 16 6)

5322551

110 2) 12 7)

180 3) 12 8)

400 4)

650 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 20: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

2 0 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

threaded sleeves Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DW01**M6

200°C

25 mm Ø 0.02 mm-40 °C

–+200 °C

1 m

20 1) –

5315234

50 2) –

95 3) –

150 4)

400 5)

LL3-DW01-2** M6

200°C

25 mm Ø 0.02 mm-40 °C

–+200 °C

2 m

20 1) –

5324789

50 2) –

95 3) –

150 4)

400 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms * With optimal measuring distance and settings. ** Humidity/level detection only in conjunction with WLL180T-P474 IR version. Mounting material included.

Page 21: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

2 1F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

threaded sleevesThrough-beam systems

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TB01 M4

Suitable for tip adapters

30 mm Ø 0.5 mm-40 °C

–+70 °C

2 m300 1) 720 6)

5308050

950 2) 315 7)

1700 3) 280 8)

3500 4)

4000 5)

LL3-TB01-10M4

Suitable for tip adapters

30 mm Ø 0.5 mm-40 °C

–+70 °C

10 m230 1) 420 6)

5308051

650 2) 165 7)

1200 3) 230 8)

2450 4)

4000 5)

LL3-TB01-30M4

Suitable for tip adapters

30 mm Ø 0.5 mm-40 °C

–+70 °C

30 m160 1) 290 6)

5315499

450 2) 110 7)

840 3) 180 8)

1700 4)

2800 5)

LL3-TB02 M4

Suitable for tip adapters

25 mm Ø 0.2 mm-40 °C

–+70 °C

2 m225 1) 470 6)

5308048

650 2) 165 7)

1200 3) 135 8)

2500 4)

4000 5)

LL3-TB08 M14

25 mm Ø 0.4 mm-40 °C

–+70 °C

10 m6600 1) 19500 6)

5325917

19500 2) 7500 7)

195003 ) 6000 8)

19500 4)

19500 5)

LL3-TH01 M4

100°C

Suitable for tip adapters

25 mm Ø 0.2 mm-40 °C

–+100 °C

2 m55 1) 305 6)

5308064

180 2) 125 7)

320 3) 50 8)

680 4)

1000 5)

LL3-TH02 M4

180°C

35 mm Ø 0.5 mm-40 °C

–+180 °C

2 m230 1) 620 6)

5308065

700 2) 255 7)

1300 3) 125 8)

2700 4)

4000 5)

LL3-TJ01 M4

10 mm Ø 0.05 mm-40 °C

–+60 °C

1 m

145 1) 40 6)

5325915

460 2) 120 7)

830 3) 150 8)

1600 4)

1770 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Fiber-optic through-beam systems

Page 22: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

2 2 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

threaded sleeves Through-beam systems

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TK77 M4

Suitable for tip adapters

2 mm Ø 0.2 mm-40 °C

–+70 °C

2 m220 1) 370 6)

5313035

650 2) 125 7)

1200 3) 120 8)

2750 4)

4000 5)

LL3-TM01 M3

25 mm Ø 0.2 mm-40 °C

–+70 °C

2 m220 1) 470 6)

5308068

680 2) 165 7)

1200 3) 135 8)

2500 4)

4000 5)

LL3-TM02 M3

15 mm Ø 0.1 mm-40 °C

–+70 °C

2 m55 1) 125 6)

5308069

175 2) 45 7)

300 3) 30 8)

700 4)

1100 5)

LL3-TR01 M4

Suitable for tip adapters

4 mm Ø 0.3 mm-40 °C

–+70 °C

2 m200 1) 340 6)

5308052

600 2) 125 7)

1000 3) 125 8)

2400 4)

4000 5)

LL3-TR01-05M4

4 mm Ø 0.3 mm-40 °C

–+70 °C

5 m160 1) 120 6)

5322198

450 2) 60 7)

800 3) 60 8)

1900 4)

2800 5)

LL3-TR02 M3

4 mm Ø 0.1 mm-40 °C

–+70 °C

2 m60 1) 115 6)

5308053

175 2) 38 7)

330 3) 23 8)

750 4)

1100 5)

LL3-TV05 M4

25 mm Ø 0.4 mm-40 °C

–+70 °C

2 m350 1) 400 6)

5322546

750 2) 170 7)

1800 3) 150 8)

4000 4)

4000 5)

LL3-TV06 M4

105°C

25 mm Ø 0.4 mm-40 °C

–+105 °C

2 m180 1) 350 6)

5322547

550 2) 150 7)

900 3) 150 8)

2100 4)

3500 5)

LL3-TV07 M4

2 mm Ø 0.4 mm-40 °C

–+70 °C

2 m340 1) 290 6)

5322548

1000 2) 150 7)

1800 3) 150 8)

4000 4)

4000 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 23: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

2 3F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

threaded sleevesThrough-beam systems

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TW01**M4

200°C

25 mm Ø 0.4 mm-40 °C

–+200 °C

1 m

80 1) –

5315233

230 2) –

350 3) –

560 4)

980 5)

LL3-TW01-2**M4

200°C

25 mm Ø 0.4 mm-40 °C

–+200 °C

2 m

80 1) –

5321306

230 2) –

350 3) –

560 4)

980 5)

LL3-TX01 M12

25 mm Ø 0.5 mm-40 °C

–+60 °C

20 m1000 1) 1500 6)

5324173

3700 2) 600 7)

7000 3) 500 8)

14000 4)

20000 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode:: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. ** Humidity/level detection only in conjunction with WLL180T-P474 IR version. Mounting material included.

Page 24: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

2 4 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

smooth sleeves Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

smooth sleeves

Cylindrical fibers are ideal for space-saving mounting. This is carried out by simply securing it with a setscrew.

Fiber-optic proximity systems

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DB10

25 mm Ø 0.02 mm-40 °C

–+70 °C

2 m70 1) 170 6)

5325999

220 2) 75 7)

360 3) 60 8)

720 4)

770 5)

LL3-DK04

25 mm Ø 0.015 mm-40 °C

–+70 °C

2 m100 1) 165 6)

5313020

300 2) 65 7)

500 3) 37 8)

900 4)

1400 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Easy to mount with setscrew

Page 25: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

2 5F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

smooth sleevesProximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DK4Z

2 mm Ø 0.015 mm-40 °C

–+70 °C

2 m65 1) 115 6)

5313026

200 2) 47 7)

350 3) 27 8)

650 4)

1000 5)

LL3-DP01

10 mm Ø 0.02 mm-40 °C

–+60 °C

2 m

– 3.5 6)

5325998

3 2) –

14 3) –

29 4)

31 5)

LL3-DR03

4 mm Ø 0.015 mm-40 °C

–+70 °C

2 m30 1) 37 6)

5308080

85 2) 13 7)

140 3) 8 8)

300 4)

600 5)

LL3-DR04

4 mm Ø 0.015 mm-40 °C

–+70 °C

1 m

20 1) 25 6)

5308081

70 2) 9 7)

110 3) 3 8)

220 4)

360 5)

LL3-DR05

4 mm Ø 0.015 mm-40 °C

–+70 °C

0.5 m

10 1) 12 6)

5308087

30 2) 4 7)

60 3) 2 8)

140 4)

225 5)

LL3-DR11

2 mm Ø 0.02 mm-40 °C

–+60 °C

2 m22 1) 65 6)

5326000

74 2) 30 7)

140 3) 20 8)

280 4)

300 5)

LL3-DR12

1 mm Ø 0.02 mm-40 °C

–+60 °C

2 m4 1) 11 6)

5326001

13 2) 5 7)

27 3) –

55 4)

59 5)

LL3-DT03

15 mm Ø 0.015 mm-40 °C

–+70 °C

2 m18 1) 47 6)

5308072

55 2) 17 7)

95 3) 7 8)

190 4)

360 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 26: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

2 6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

smooth sleeves Through-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TB07

25 mm Ø 0.03 mm-40 °C

–+70 °C

2 m180 1) 400 6)

5325919

540 2) 190 7)

890 3) 200 8)

1700 4)

1900 5)

LL3-TG05

1 mm Ø 0.02 mm-40 °C

–+60 °C

2 m13 1) 25 6)

5325921

50 2) 12 7)

85 3) 12 8)

170 4)

180 5)

LL3-TH06

10 mm Ø 10 mm-40 °C

–+105 °C

1 m6 1) 18 6)

5325926

19 2) 7 7)

38 3) 11 8)

74 4)

130 5)

LL3-TK05

2 mm Ø 0.2 mm-40 °C

–+70 °C

2 m220 1) 370 6)

5313034

650 2) 125 7)

1200 3) 120 8)

2750 4)

4000 5)

LL3-TM03

15 mm Ø 0.1 mm-40 °C

–+70 °C

2 m55 1) 125 6)

5308070

175 2) 45 7)

300 3) 30 8)

700 4)

1100 5)

LL3-TR03

4 mm Ø 0.1 mm-40 °C

–+70 °C

1 m60 1) 115 6)

5308054

175 2) 38 7)

330 3) 23 8)

750 4)

1100 5)

LL3-TR03-2

4 mm Ø 0.1 mm-40 °C

–+70 °C

2 m60 1) 115 6)

5308055

175 2) 38 7)

330 3) 23 8)

750 4)

1100 5)

LL3-TR04

4 mm Ø 0.02 mm-40 °C

–+60 °C

0.5 m

5 1) 12 6)

5325918

17 2) 5 7)

28 3) 5 8)

56 4)

60 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Fiber-optic through-beam systems

Page 27: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

2 7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

smooth sleevesThrough-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TR10

1 mm Ø 0.02 mm-40 °C

–+60 °C

2 m380 1) 800 6)

5325920

1220 2) 250 7)

2000 3) 250 8)

4000 4)

4000 5)

LL3-TS07

30 mm Ø 0.5 mm-40 °C

–+70 °C

2 m275 1) 720 6)

5308049

1000 2) 315 7)

1800 3) 280 8)

3500 4)

4000 5)

LL3-TS22V

1 mm Ø 0.05 mm-40 °C

–+70 °C

2 m380 1) 800 6)

5325923

1280 2) 800 7)

2560 3) 700 8)

4000 4)

4000 5)

LL3-TV08

25 mm Ø 0.05 mm-40 °C

–+60 °C

2 m590 1) 1100 6)

5325922

1790 2) 600 7)

2400 3) 500 8)

4000 4)

4000 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 28: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

2 8 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

90° deflection Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

90° deflection

Fibers with integrated 90° deflection are the ideal solution for small installation depths and tight installation spaces. The fiber-optic cable can be installed close to the machine body to save space.

Fiber-optic proximity systems

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DB09

25 mm Ø 0.02 mm-40 °C

–+70 °C

2 m47 1) 110 6)

5325991

165 2) 55 7)

285 3) 30 8)

575 4)

610 5)

LL3-DK33

25 mm Ø 0.025 mm-40 °C

–+70 °C

2 m35 1) 95 6)

5313031

135 2) 41 7)

170 3) 27 8)

290 4)

320 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Fibers with hexagon head for space-saving installation The fiber-optic tip can be brought very close to the object

Page 29: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

2 9F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

90° deflectionProximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DR12

1 mm Ø 0.02 mm-40 °C

–+60 °C

2 m4 1) 11 6)

5326001

13 2) 5 7)

27 3) –

55 4)

59 5)

LL3-DV01

25 mm Ø 0.025 mm-40 °C

–+70 °C

2 m40 1) 95 6)

5308088

135 2) 41 7)

180 3) 22 8)

270 4)

330 5)

LL3-DV02

15 mm Ø 0.015 mm-40 °C

–+70 °C

2 m10 1) 16 6)

5308089

35 2) 3 7)

70 3) 3 8)

125 4)

290 5)

LL3-DV03

25 mm Ø 0.025 mm-40 °C

–+70 °C

2 m35 1) 95 6)

5308090

135 2) 41 7)

170 3) 22 8)

290 4)

320 5)

LL3-DV05 M6

25 mm Ø 0.015 mm-40 °C

–+70 °C

2 m25 1) 47 6)

5322549

110 2) 17 7)

185 3) 17 8)

400 4)

650 5)

LL3-DV06 M6

105°C

25 mm Ø 0.015 mm-40 °C

–+105 °C

2 m30 1) 47 6)

5322550

130 2) 12 7)

210 3) 12 8)

450 4)

800 5)

LL3-DV07 M6

2 mm Ø 0.015 mm-40 °C

–+70 °C

2 m20 1) 16 6)

5322551

110 2) 12 7)

180 3) 12 8)

400 4)

650 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 30: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

3 0 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

90° deflection Through-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TB06

25 mm Ø 0.05 mm-40 °C

–+70 °C

2 m150 1) 400 6)

5325916

480 2) 170 7)

770 3) 150 8)

1500 4)

1600 5)

LL3-TG02

1 mm Ø 0.06 mm-40 °C

–+55 °C

2 m580 1) 1100 6)

5325943

1670 2) 450 7)

2400 3) 700 8)

4000 4)

4000 5)

LL3-TG05

1 mm Ø 0.02 mm-40 °C

–+60 °C

2 m13 1) 25 6)

5325921

50 2) 12 7)

85 3) 12 8)

170 4)

180 5)

LL3-TH06

10 mm Ø 10 mm-40 °C

–+105 °C

1 m6 1) 18 6)

5325926

19 2) 7 7)

38 3) 11 8)

74 4)

130 5)

LL3-TH07

200°C

50 mm Ø 0.1 mm-60 °C

–+200 °C

2 m

18 1) –

5325977

30 2) 23 6)

120 3) –

220 4)

420 5)

LL3-TH15

200°C

25 mm Ø 0.16 mm-60 °C

–+200 °C

2 m90 1) 170 6)

5325975

290 2) 75 7)

480 3) 110 8)

970 4)

1000 5)

LL3-TH16

200°C

25 mm Ø 0.16 mm-60 °C

–+200 °C

2 m90 1) 170 6)

5325976

290 2) 75 7)

480 3) 110 8)

970 4)

1000 5)

LL3-TK16

25 mm Ø 0.2 mm-40 °C

–+100 °C

2 m180 1) 2050 6)

5313038

600 2) 950 7)

1100 3) 850 8)

2500 4)

3300 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Fiber-optic through-beam systems

Page 31: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

3 1F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

90° deflectionThrough-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TR08

1 mm Ø 0.06 mm-40 °C

–+60 °C

2 m160 1) 350 6)

5325984

480 2) 170 7)

800 3) 150 8)

1600 4)

1700 5)

LL3-TR09

1 mm Ø 0.04 mm-40 °C

–+60 °C

2 m360 1) 900 6)

5325985

1200 2) 500 7)

2200 3) 450 8)

4000 4)

4000 5)

LL3-TS08

25 mm Ø 0.2 mm-40 °C

–+70 °C

2 m170 1) 355 6)

5308061

500 2) 125 7)

1000 3) 115 8)

2300 4)

3000 5)

LL3-TS12

25 mm Ø 0.5 mm-40 °C

–+70 °C

2 m170 1) 1800 6)

5308062

550 2) 840 7)

1000 3) 760 8)

2300 4)

3000 5)

LL3-TS22

25 mm Ø 0.05 mm-40 °C

–+70 °C

2 m390 1) 850 6)

5325944

1300 2) –

2600 3) –

4000 4)

4000 5)

LL3-TS22M

105°C

10 mm Ø 0.05 mm-40 °C

–+105 °C

2 m220 1) 625 6)

5325968

760 2) –

1500 3) –

2900 4)

4000 5)

LL3-TS22V

1 mm Ø 0.05 mm-40 °C

–+70 °C

2 m380 1) 800 6)

5325923

1280 2) 800 7)

2560 3) 700 8)

4000 4)

4000 5)

LL3-TV01

25 mm Ø 0.2 mm-40 °C

–+70 °C

2 m120 1) 325 6)

5308058

400 2) 115 7)

800 3) 87 8)

1800 4)

2750 5)

LL3-TV02

15 mm Ø 0.1 mm-40 °C

–+70 °C

2 m30 1) 77 6)

5308059

130 2) 27 7)

250 3) 16 8)

550 4)

800 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 32: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

3 2 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

90° deflection Through-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TV04

15 mm Ø 0.1 mm-40 °C

–+70 °C

2 m30 1) 77 6)

5308060

130 2) 27 7)

250 3) 16 8)

550 4)

800 5)

LL3-TV05 M4

25 mm Ø 0.4 mm-40 °C

–+70 °C

2 m350 1) 400 6)

5322546

750 2) 170 7)

1800 3) 150 8)

4000 4)

4000 5)

LL3-TV06 M4

105°C

25 mm Ø 0.4 mm-40 °C

–+105 °C

2 m180 1) 350 6)

5322547

550 2) 150 7)

900 3) 150 8)

2100 4)

3500 5)

LL3-TV07 M4

2 mm Ø 0.4 mm-40 °C

–+70 °C

2 m340 1) 290 6)

5322548

1000 2) 150 7)

1800 3) 150 8)

4000 4)

4000 5)

LL3-TV08

25 mm Ø 0.05 mm-40 °C

–+60 °C

2 m590 1) 1100 6)

5325922

1790 2) 600 7)

2400 3) 500 8)

4000 4)

4000 5)

LL3-TY02

60 mm Ø 0.3 mm-40 °C

–+70 °C

2 m

300 1) 620 6)

5308067

1000 2) 225 7)

1300 3) 210 8)

3000 4)

4000 5)

LL3-TY03

20 mm Ø 0.3 mm-55°C

–+70 °C

2 m460 1) 1000 6)

5325982

1400 2) 350 7)

2500 3) 450 8)

4000 4)

4000 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 33: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

3 3F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

90° deflection

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Page 34: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

3 4 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Flat design Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Flat design

The rectangular, flat fibers are easy to mount.The fiber-optic cable of the LL3-xE02 and LL3-xE04 models can be adjusted so that the light emission points upward or to the side. This reduces the number of models that need to be stored in the warehouse.

Fiber-optic proximity systems

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DC03

25 mm Ø 0.3 mm-40 °C

–+60 °C

2 m12-60 1) 7-80 6)

5326020

10-75 2) 10-60 7)

5-85 3) 10-60 8)

3-150 4)

2-280 5)

LL3-DC04

4 mm Ø 0.4 mm0 °C

–+70 °C

2 m4-18 1) 1-20 6)

5326018

0-31 2) 1-20 7)

0-34 3) 4-15 8)

0-38 4)

0-38 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

The adjustable fiber-optic cable allows the same model to be used with the light emission pointing upward or to the side

Flush installation in the side frames Detection of sheets

Page 35: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

3 5F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Flat designProximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DC05

25 mm 0.25 mm0 °C

–+70 °C

2 m9-18 1) 5-22 6)

5326016

7-29 2) 5-22 7)

5-35 3) 6-25 8)

4-40 4)

3-43 5)

LL3-DC06

4 mm 0.4 mm0 °C

–+70 °C

2 m4-15 1) 2-15 6)

5326017

2-22 2) 2-15 7)

0-23 3) 3-10 8)

0-25 4)

0-25 5)

LL3-DC07

10 mm Ø 0.06 mm-40 °C

–+60 °C

2 m7-8 1) 5-10 6)

5326019

4-12 2) 7-8 7)

4-14 3) 7-8 8)

2-16 4)

2-18 5)

LL3-DC08

1 mm Ø 0.3 mm-20 °C

–+60 °C

2 m1-2 1) 1-4.5 6)

5326029

1-4 2) 1-2.5 7)

1-6 3) 1-2.5 8)

0-9 4)

0-10 5)

LL3-DC09

10 mm Ø 0.02 mm-40 °C

–+70 °C

2 m6-8 1) 5-8 6)

5326028

6-10 2) 5-8 7)

5-11 3) 5-8 8)

4-13 4)

0-17 5)

LL3-DC38

10 mm Ø 0.02 mm-40 °C

–+50 °C

2 m6 1) 4-7 6)

5322472

6 2) 4-7 7)

6 3) 4-6 8)

1-10 4)

0-15 5)

LL3-DC39

10 mm Ø 0.02 mm-40 °C

–+50 °C

2 m– 0-5 6)

5322513

0-4 2) 0-4 7)

0-4 3) 0-4 8)

0-4 4)

0-45)

LL3-DC47

1 mm Ø 0.01 mm-40 °C

–+60 °C

2 m12 1) 30 6)

5324268

25 2) 10 7)

37 3) 5 8)

75 4)

90 5)

LL3-DC57

1 mm Ø 0.01 mm-40 °C

–+60 °C

2 m35 1) 50 6)

5324269

45 2) 35 7)

55 3) 10 8)

250 4)

330 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 36: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

3 6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Flat design Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DE01

1 mm Ø 0.16 mm-40 °C

–+60 °C

1 m11 1) 35 6)

5325285

38 2) 6-8 7)

78 3) –

150 4)

160 5)

LL3-DE02

1 mm Ø 0.01 mm-40 °C

–+60 °C

1 m13 1) 35 6)

5324497

48 2) 15 7)

86 3) 12 8)

170 4)

180 5)

LL3-DE03

1 mm Ø 0.03 mm-40 °C

–+60 °C

2 m45 1) 110 6)

5325986

130 2) 43 7)

250 3) 31 8)

510 4)

550 5)

LL3-DE04

1 mm Ø 0.03 mm-40 °C

–+60 °C

2 m50 1) 110 6)

5325987

130 2) 50 7)

250 3) 35 8)

500 4)

540 5)

LL3-DH06

300°C

25 mm Ø 0.02 mm-30 °C

–+300 °C

2 m

3-5 1) 7 6)

5326026

0-10 2) 0.3-10.5 7)

0-19 3) 1.2-9 8)

0-37 4)

0-43 5)

LL3-DH08

25 mm Ø 0.02 mm-60 °C

–+180 °C

2 m2-5 1) 11 6)

5326025

0-11 2) 0-15.5 7)

0-22 3) 0.5-9.3 8)

0-30 4)

0-38 5)

LL3-DH10

250°C

25 mm Ø 0.02 mm-20 °C

–+250 °C

2 m

4-11 1) 3.5-18 6)

5326023

3-18 2) 4-18 7)

3-21 3) 4-15 8)

2-24 4)

2-26 5)

LL3-DH11

250°C

25 mm Ø 0.02 mm-20 °C

–+250 °C

2 m

8-19 1) 7.5-24 6)

5326024

6-29 2) 7.5-24 7)

4-34 3) 9-24 8)

3-39 4)

2-42 5)

LL3-DR09

1 mm Ø 0.03 mm-20 °C

–+70 °C

2 m110 1) 300 6)

5325528

345 2) 120 7)

560 3) 80 8)

1100 4)

1190 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 37: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

3 7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Flat designThrough-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TE01

1 mm Ø 0.08 mm-40 °C

–+60 °C

1 m120 1) 250 6)

5325807

350 2) 120 7)

620 3) 120 8)

1250 4)

1330 5)

LL3-TE02

1 mm Ø 0.08 mm-40 °C

–+60 °C

1 m40 1) 130 6)

5325910

140 2) 60 7)

220 3) 50 8)

450 4)

480 5)

LL3-TE03

1 mm Ø 0.08 mm-40 °C

–+60 °C

2 m190 1) 500 6)

5325908

580 2) 250 7)

980 3) 200 8)

1970 4)

2100 5)

LL3-TE04

1 mm Ø 0.03 mm-40 °C

–+60 °C

2 m150 1) 320 6)

5325911

440 2) 160 7)

700 3) 120 8)

1400 4)

1490 5)

LL3-TE05

4 mm Ø 0.03 mm-40 °C

–+60 °C

2 m150 1) 350 6)

5325914

460 2) 140 7)

840 3) 240 8)

1680 4)

1780 5)

LL3-TR05

4 mm Ø 0.03 mm-40 °C

–+60 °C

2 m360 1) 1200 6)

5325808

1300 2) 500 7)

2300 3) 750 8)

4000 4)

4000 5)

LL3-TR06

4 mm Ø 0.03 mm-40 °C

–+60 °C

2 m560 1) 1200 6)

5325912

1600 2) 500 7)

2200 3) 750 8)

4000 4)

4000 5)

LL3-TR11

1 mm Ø 0.08 mm-40 °C

–+60 °C

2 m590 1) 1800 6)

5325906

1500 2) –

2200 3) 750 8)

4000 4)

4000 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Fiber-optic through-beam systems

Page 38: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

3 8 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Flat design Through-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TR12

1 mm Ø 0.05 mm-40 °C

–+60 °C

2 m600 1) 1400 6)

5325907

1400 2) 650 7)

2300 3) 600 8)

4000 4)

4000 5)

LL3-TR13

1 mm Ø 0.04 mm-40 °C

–+60 °C

2 m250 1) 600 6)

5325909

730 2) 300 7)

1280 3) 400 8)

2560 4)

2730 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 39: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

3 9F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Flat design

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Page 40: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

4 0 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Highly-flexible fibers Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Highly-flexible fibers

The highly-flexible fibers can be bent to a minimum bend radius of 1 mm. This means that you do not need to worry about damaging the fibers during installation.

Fiber-optic proximity systems

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DC04

4 mm Ø 4 mm0 °C

–+70 °C

3 m4-18 1) 1-20 6)

5326018

0-31 2) 1-20 7)

0-34 3) 4-15 8)

0-38 4)

0-38 5)

LL3-DC06

4 mm Ø 4 mm0 °C

–+70 °C

2 m4-15 1) 2-15 6)

5326017

2-22 2) 2-15 7)

0-23 3) 3-10 8)

0-25 4)

0-25 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Highly-flexible fibers Standard fibers

Page 41: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

4 1F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Highly-flexible fibersProximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DC47

1 mm Ø 0.01 mm-40 °C

–+60 °C

2 m12 1) 30 6)

5324268

25 2) 10 7)

37 3) 5 8)

75 4)

90 5)

LL3-DC57

1 mm Ø 0.01 mm-40 °C

–+60 °C

2 m35 1) 50 6)

5324269

45 2) 35 7)

55 3) 10 8)

250 4)

330 5)

LL3-DE01

1 mm Ø 0.16 mm-40 °C

–+60 °C

1 m11 1) 35 6)

5325285

38 2) 6-8 7)

78 3) –

150 4)

160 5)

LL3-DE02

1 mm Ø 0.01 mm-40 °C

–+60 °C

1 m13 1) 35 6)

5324497

48 2) 15 7)

86 3) 12 8)

170 4)

180 5)

LL3-DE03

1 mm Ø 0.03 mm-40 °C

–+60 °C

2 m45 1) 110 6)

5325986

130 2) 43 7)

250 3) 31 8)

510 4)

550 5)

LL3-DE04

1 mm Ø 0.03 mm-40 °C

–+60 °C

2 m50 1) 110 6)

5325987

130 2) 50 7)

250 3) 35 8)

500 4)

540 5)

LL3-DK4Z

2 mm Ø 0.015 mm-40 °C

–+70 °C

2 m65 1) 115 6)

5313026

200 2) 47 7)

350 3) 27 8)

650 4)

1000 5)

LL3-DK63Z

2 mm Ø 0.015 mm-40 °C

–+70 °C

2 m90 1) 115 6)

5313027

300 2) 47 7)

500 3) 27 8)

900 4)

1400 5)

LL3-DK66 M4

2 mm Ø 0.015 mm-40 °C

–+70 °C

2 m90 1) 115 6)

5313024

300 2) 47 7)

500 3) 27 8)

900 4)

1400 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 42: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

4 2 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Highly-flexible fibers Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DK67 M6

2 mm Ø 0.015 mm-40 °C

–+70 °C

2 m90 1) 115 6)

5313025

300 2) 47 7)

500 3) 27 8)

900 4)

1400 5)

LL3-DR01 M6

4 mm Ø 0.015 mm-40 °C

–+70 °C

2 m90 1) 135 6)

5308078

280 2) 50 7)

450 3) 20 8)

880 4)

1350 5)

LL3-DR02 M3

4 mm Ø 0.015 mm-40 °C

–+70 °C

1 m18 1) 22 6)

5308079

50 2) 9 7)

90 3) 3 8)

200 4)

370 5)

LL3-DR03

4 mm Ø 0.015 mm-40 °C

–+70 °C

2 m30 1) 37 6)

5308080

85 2) 13 7)

140 3) 8 8)

300 4)

600 5)

LL3-DR04

4 mm Ø 0.015 mm-40 °C

–+70 °C

1 m

20 1) 25 6)

5308081

70 2) 9 7)

110 3) 3 8)

220 4)

360 5)

LL3-DR06 M4

4 mm Ø 0.015 mm-40 °C

–+70 °C

2 m18 1) 37 6)

5308082

60 2) 11 7)

100 3) 5 8)

220 4)

360 5)

LL3-DR09

1 mm Ø 0.03 mm-20 °C

–+70 °C

2 m110 1) 300 6)

5325528

345 2) 120 7)

560 3) 80 8)

1100 4)

1190 5)

LL3-DR12

1 mm Ø 0.02 mm-40 °C

–+60 °C

2 m4 1) 11 6)

5326001

13 2) 5 7)

27 3) –

55 4)

59 5)

LL3-DT02

4 mm Ø 0.015 mm-40 °C

–+70 °C

0.5 m10 1) 9 6)

5308085

30 2) 4 7)

60 3) 2 8)

140 4)

225 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 43: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

4 3F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Highly-flexible fibersThrough-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DT04

4 mm Ø 0.015 mm-40 °C

–+70 °C

0.5 m

13 1) 9 6)

5308086

45 2) 4 7)

80 3) 2 8)

140 4)

280 5)

LL3-DV07 M6

2 mm Ø 0.015 mm-40 °C

–+70 °C

2 m20 1) 16 6)

5322551

110 2) 12 7)

180 3) 12 8)

400 4)

650 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TE01

1 mm Ø 0.08 mm-40 °C

–+60 °C

1 m120 1) 250 6)

5325807

350 2) 120 7)

620 3) 120 8)

1250 4)

1330 5)

LL3-TE02

1 mm Ø 0.08 mm-40 °C

–+60 °C

1 m40 1) 130 6)

5325910

140 2) 60 7)

220 3) 50 8)

450 4)

480 5)

LL3-TE03

1 mm Ø 0.08 mm-40 °C

–+60 °C

2 m190 1) 500 6)

5325908

580 2) 250 7)

980 3) 200 8)

1970 4)

2100 5)

LL3-TE04

1 mm Ø 0.03 mm-40 °C

–+60 °C

2 m150 1) 320 6)

5325911

440 2) 160 7)

700 3) 120 8)

1400 4)

1490 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Fiber-optic through-beam systems

Page 44: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

4 4 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Highly-flexible fibers Through-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TE05

4 mm Ø 0.03 mm-40 °C

–+60 °C

2 m150 1) 350 6)

5325914

460 2) 140 7)

840 3) 240 8)

1680 4)

1780 5)

LL3-TG02

1 mm Ø 0.06 mm-40 °C

–+55 °C

2 m580 1) 1100 6)

5325943

1670 2) 450 7)

2400 3) 700 8)

4000 4)

4000 5)

LL3-TG05

1 mm Ø 0.02 mm-40 °C

–+60 °C

2 m13 1) 25 6)

5325921

50 2) 12 7)

85 3) 12 8)

170 4)

180 5)

LL3-TK05

2 mm Ø 0.2 mm-40 °C

–+70 °C

2 m220 1) 370 6)

5313034

650 2) 125 7)

1200 3) 120 8)

2750 4)

4000 5)

LL3-TK77 M4

Suitable for tip adapters

2 mm Ø 0.2 mm-40 °C

–+70 °C

2 m220 1) 370 6)

5313035

650 2) 125 7)

1200 3) 120 8)

2750 4)

4000 5)

LL3-TR01 M4

Suitable for tip adapters

4 mm Ø 0.3 mm-40 °C

–+70 °C

2 m200 1) 340 6)

5308052

600 2) 125 7)

1000 3) 125 8)

2400 4)

4000 5)

LL3-TR01-05 M4

4 mm Ø 0.3 mm-40 °C

–+70 °C

5 m160 1) 120 6)

5322198

450 2) 60 7)

800 3) 60 8)

1900 4)

2800 5)

LL3-TR02 M3

4 mm Ø 0.1 mm-40 °C

–+70 °C

2 m60 1) 115 6)

5308053

175 2) 38 7)

330 3) 23 8)

750 4)

1100 5)

LL3-TR03

4 mm Ø 0.1 mm-40 °C

–+70 °C

1 m60 1) 115 6)

5308054

175 2) 38 7)

330 3) 23 8)

750 4)

1100 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 45: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

4 5F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Highly-flexible fibersThrough-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TR03-2

4 mm Ø 0.1 mm-40 °C

–+70 °C

2 m60 1) 115 6)

5308055

175 2) 38 7)

330 3) 23 8)

750 4)

1100 5)

LL3-TR04

4 mm Ø 0.02 mm-40 °C

–+60 °C

0.5 m

5 1) 12 6)

5325918

17 2) 5 7)

28 3) 5 8)

56 4)

60 5)

LL3-TR05

4 mm Ø 0.03 mm-40 °C

–+60 °C

2 m360 1) 1200 6)

5325808

1300 2) 500 7)

2300 3) 750 8)

4000 4)

4000 5)

LL3-TR06

4 mm Ø 0.03 mm-40 °C

–+60 °C

2 m560 1) 1200 6)

5325912

1600 2) 500 7)

2200 3) 750 8)

4000 4)

4000 5)

LL3-TR08

1 mm Ø 0.06 mm-40 °C

–+60 °C

2 m160 1) 350 6)

5325984

480 2) 170 7)

800 3) 150 8)

1600 4)

1700 5)

LL3-TR09

1 mm Ø 0.04 mm-40 °C

-+60 °C

2 m360 1) 900 6)

5325985

1200 2) 500 7)

2200 3) 450 8)

4000 4)

4000 5)

LL3-TR10

1 mm Ø 0.02 mm-40 °C

–+60 °C

2 m380 1) 800 6)

5325920

1220 2) 250 7)

2000 3) 250 8)

4000 4)

4000 5)

LL3-TR11

1 mm Ø 0.08 mm-40 °C

–+60 °C

2 m590 1) 1800 6)

5325906

1500 2) –

2200 3) 750 8)

4000 4)

4000 5)

LL3-TR12

1 mm Ø 0.05 mm-40 °C

–+60 °C

2 m600 1) 1400 6)

5325907

1400 2) 650 7)

2300 3) 600 8)

4000 4)

4000 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 46: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

4 6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Highly-flexible fibers Through-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TR13

1 mm Ø 0.04 mm-40 °C

–+60 °C

2 m250 1) 600 6)

5325909

730 2) 300 7)

1280 3) 400 8)

2560 4)

2730 5)

LL3-TS22V

1 mm Ø 0.05 mm-40 °C

–+70 °C

2 m380 1) 800 6)

5325923

1280 2) 800 7)

2560 3) 700 8)

4000 4)

4000 5)

LL3-TV07 M4

2 mm Ø 0.4 mm-40 °C

–+70 °C

2 m340 1) 290 6)

5322548

1000 2) 150 7)

1800 3) 150 8)

4000 4)

4000 5)

LL3-TZ09

1 mm Ø 0.25 mm-40 °C

–+55 °C

2 m1300 1) 3700 6)

5326598

2500 2) 1200 7)

3000 3) 1000 8)

3500 4)

4000 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 47: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

4 7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Highly-flexible fibers

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Page 48: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

4 8 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

long end sleeves Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

long end sleeves

Fibers with long end sleeves are easy to position even in the tightest of spaces. This provides reliable detection of even the smallest objects. Bendable end sleeves offer maximum flexibility for alignment.

Fiber-optic proximity systems

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DB02

25 mm Ø 0.015 mm-40 °C

–+70 °C

2 m100 1) 170 6)

5308083

350 2) 67 7)

580 3) 42 8)

850 4)

1300 5)

LL3-DB05

25 mm Ø 0.02 mm-40 °C

–+60 °C

2 m

8 1) 22 6)

5326002

25 2) 6 7)

52 3) 6 8)

100 4)

110 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Bendable end sleeves Standard model with long end sleeves

Page 49: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

4 9F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

long end sleevesProximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DB06

25 mm Ø 0.02 mm-40 °C

–+70 °C

2 m60 1) 150 6)

5326006

210 2) 60 7)

360 3) 40 8)

700 4)

760 5)

LL3-DB08

25 mm Ø 0.02 mm-40 °C

–+70 °C

2 m17 1) 45 6)

5326004

55 2) 18 7)

107 3) 13 8)

200 4)

220 5)

LL3-DH04

350°C

25 mm Ø 0.02 mm-30 °C

–+350 °C

2 m

65 1) 350 6)

5326022

225 2) 120 7)

500 3) 90 8)

1000 4)

1060 5)

LL3-DH05

350°C

25 mm Ø 0.02 mm-30 °C

–+350 °C

2 m

55 1) 220 6)

5326021

220 2) 90 7)

580 3) 70 8)

1170 4)

1240 5)

LL3-DK33

25 mm Ø 0.025 mm-40 °C

–+70 °C

2 m35 1) 95 6)

5313031

135 2) 41 7)

170 3) 27 8)

290 4)

320 5)

LL3-DK43

15 mm Ø 0.015 mm-40 °C

–+70 °C

2 m10 1) 47 6)

5313030

28 2) 17 7)

45 3) 8 8)

93 4)

170 5)

LL3-DK63Z

2 mm Ø 0.015 mm-40 °C

–+70 °C

2 m90 1) 115 6)

5313027

300 2) 47 7)

500 3) 27 8)

900 4)

1400 5)

LL3-DM03

15 mm Ø 0.015 mm-40 °C

–+70 °C

2 m10 1) 50 6)

5308084

25 2) 17 7)

45 3) 8 8)

90 4)

170 5)

LL3-DR07

25 mm Ø 0.015 mm-40 °C

–+70 °C

2 m

5 1) 7 6)

5326007

15 2) 3 8)

35 3) –

65 4)

120 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 50: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

5 0 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

long end sleeves Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DR10

1 mm Ø 0.02 mm-40 °C

–+60 °C

2 m12 1) 35 6)

5326005

40 2) 15 7)

77 3) 9 8)

150 4)

160 5)

LL3-DT02

4 mm Ø 0.015 mm-40 °C

–+70 °C

2 m10 1) 9 6)

5308085

30 2) 4 7)

60 3) 2 8)

140 4)

225 5)

LL3-DT04

4 mm Ø 0.015 mm-40 °C

–+70 °C

0.5 m

13 1) 9 6)

5308086

45 2) 4 7)

80 3) 2 8)

140 4)

280 5)

LL3-DT05

15 mm Ø 0.015 mm-40 °C

–+70 °C

2 m10 1) 50 6)

5313028

28 2) 17 7)

45 3) 8 8)

95 4)

170 5)

LL3-DV01

25 mm Ø 0.025 mm-40 °C

–+70 °C

2 m40 1) 95 6)

5308088

135 2) 41 7)

180 3) 22 8)

270 4)

330 5)

LL3-DV02

15 mm Ø 0.015 mm-40 °C

–+70 °C

2 m10 1) 16 6)

5308089

35 2) 3 7)

70 3) 3 8)

125 4)

290 5)

LL3-DV03

25 mm Ø 0.025 mm-40 °C

–+70 °C

2 m35 1) 95 6)

5308090

135 2) 41 7)

170 3) 22 8)

290 4)

320 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 51: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

5 1F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

long end sleevesThrough-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TB03

25 mm Ø 0.2 mm-40 °C

–+70 °C

2 m240 1) 470 6)

5308056

700 2) 165 7)

1400 3) 132 8)

2500 4)

2900 5)

LL3-TB05

25 mm Ø 0.03 mm-40 °C

–+70 °C

2 m50 1) 120 6)

5325924

140 2) 60 7)

250 3) 60 8)

500 4)

530 5)

LL3-TK16

25 mm Ø 0.2 mm-40 °C

–+100 °C

2 m180 1) 2050 6)

5313038

600 2) 950 7)

1100 3) 850 8)

2500 4)

3300 5)

LL3-TP01

5 mm Ø 0.02 mm-40 °C

–+70 °C

0.5 m

2 1) 5 6)

5325925

8 2) 3 7)

14 3) 3 8)

28 4)

30 5)

LL3-TS08

25 mm Ø 0.2 mm-40 °C

–+70 °C

2 m170 1) 355 6)

5308061

500 2) 125 7)

1000 3) 115 8)

2300 4)

3000 5)

LL3-TS12

25 mm Ø 0.5 mm-40 °C

–+70 °C

2 m170 1) 1800 6)

5308062

550 2) 840 7)

1000 3) 760 8)

2300 4)

3000 5)

LL3-TT01

15 mm Ø 0.1 mm-40 °C

–+70 °C

2 m10 1) 32 6)

5308057

30 2) 13 7)

60 3) 5 8)

140 4)

200 5)

LL3-TV01

25 mm Ø 0.2 mm-40 °C

–+70 °C

2 m120 1) 325 6)

5308058

400 2) 115 7)

800 3) 87 8)

1800 4)

2750 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Fiber-optic through-beam systems

Page 52: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

5 2 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

long end sleeves Through-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TV02

15 mm Ø 0.1 mm-40 °C

–+70 °C

2 m30 1) 77 6)

5308059

130 2) 27 7)

250 3) 16 8)

550 4)

800 5)

LL3-TV04

15 mm Ø 0.1 mm-40 °C

–+70 °C

2 m30 1) 77 6)

5308060

130 2) 27 7)

250 3) 16 8)

550 4)

800 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 53: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

5 3F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

long end sleeves

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Page 54: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

5 4 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Area detection Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Area detection

Area detection fibers are ideal for detecting objects at any point in the light array and for comparing height differences. Optional slotted diaphragms for limiting the detection area enable even very small objects to be detected.

Fiber-optic proximity systems

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll 180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DZ01

25 mm Ø 0.02 mm-40 °C

–+60 °C

2 m65 1) –

5326013

240 2) –

320 3) –

650 4)

690 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Detection of lead frames Detection of free falling tablets Monitoring of web edges

Counting pieces on a conveyor Front-edge detection for PCBs

Page 55: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

5 5F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Area detectionThrough-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DZ02

25 mm Ø 0.02 mm-40 °C

–+70 °C

2 m57 1) 150 6)

5326014

190 2) 70 7)

310 3) 50 8)

630 4)

670 5)

LL3-DZ03

25 mm Ø 0.02 mm-40 °C

–+70 °C

2 m50 1) 110 6)

5326015

160 2) 55 7)

280 3) 35 8)

450 4)

590 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TS10

Array width:5.25 mm

25 mm Ø 1 mm-40 °C

–+70 °C

2 m130 1) 335 6)

5308063

400 2) 125 7)

800 3) 90 8)

2000 4)

3500 5)

LL3-TS14

Array width:10.5 mm

25 mm Ø 0.5 mm-40 °C

–+70 °C

2 m130 1) 335 6)

5313039

400 2) 125 7)

800 3) 90 8)

2000 4)

3500 5)

LL3-TS40

Array width:40 mm

2 mm Ø 0.4 mm-40 °C

–+60 °C

2 m3000 1) 4000 6)

5323971

4000 2) 1300 7)

4000 3) 1600 8)

4000 4)

4000 5)

LL3-TZ05

Array width:5.25 mm

25 mm Ø 0.45 mm-40 °C

–+70 °C

2 m150 1) 350 6)

5325937

450 2) 150 7)

740 3) 250 8)

1400 4)

1500 5)

LL3-TZ06

Array width:5.25 mm

25 mm Ø 0.45 mm-40 °C

–+70 °C

2 m150 1) 350 6)

5325938

480 2) 150 7)

790 3) 250 8)

1500 4)

1600 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Fiber-optic through-beam systems

Page 56: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

5 6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Area detection Through-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TZ09

Array width:11 mm

1 mm Ø 0.25 mm-40 °C

–+55 °C

2 m1300 1) 2000 6)

5326598

2500 2) 800 7)

3000 3) 1000 8)

3500 4)

4000 5)

LL3-TZ10

Array width:11 mm

10 mm Ø 0.25 mm-40 °C

–+70 °C

2 m1700 1) 2800 6)

5326599

2500 2) 800 7)

3000 3) 1200 8)

3500 4)

4000 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 57: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

5 7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Area detection

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Page 58: Sick Fibre Optic Sensors and Fibers

300°C

C

8014999/2012-05Subject to change without notice

5 8 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Heat-resistant Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Heat-resistant

An extensive range of heat-resistant fibers meet every require-ment. These fibers can withstand ambient temperatures of up to 350 °C. The fiber-optic material for fibers used in ambient temperatures of up to +180 °C is plastic; for temperatures above +200 °C it is glass.

Fiber-optic proximity systems

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DH01 M6

180°C

35 mm Ø 0.015 mm-40 °C

–+180 °C

2 m120 1) 220 6)

5308091

350 2) 95 7)

600 3) 45 8)

980 4)

1500 5)

LL3-DH01-03M6

180°C

35 mm Ø 0.015 mm-40 °C

–+180 °C

3 m100 1) 150 6)

5321260

300 2) 85 7)

500 3) 40 8)

850 4)

1400 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Detection in an oven

Page 59: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

5 9F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Heat-resistantProximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DH02 M6

100°C

25 mm Ø 0.015 mm-40 °C

–+100 °C

2 m70 1) 125 6)

5308092

230 2) 45 7)

350 3) 8 8)

600 4)

1000 5)

LL3-DH03

350°C

25 mm Ø 0.02 mm-30 °C

–+350 °C

2 m

55 1) 170 6)

5324787

220 2) 80 7)

490 3) 50 8)

990 4)

1050 5)

LL3-DH04

350°C

25 mm Ø 0.02 mm-30 °C

–+350 °C

2 m

65 1) 350 6)

5326022

225 2) 120 7)

500 3) 90 8)

1000 4)

1060 5)

LL3-DH05

350°C

25 mm Ø 0.02 mm-30 °C

–+350 °C

2 m

55 1) 220 6)

5326021

220 2) 90 7)

580 3) 70 8)

1170 4)

1240 5)

LL3-DH06

300°C

25 mm Ø 0.02 mm-30 °C

–+300 °C

2 m

3-5 1) 7 6)

5326026

0-10 2) 0.3-10.5 7)

0-19 3) 1.2-9 8)

0-37 4)

0-43 5)

LL3-DH07

200°C

25 mm Ø 0.02 mm-60 °C

–+200 °C

2 m

65 1) 220 6)

5326031

260 2) 100 7)

670 3) 70 8)

1340 4)

1430 5)

LL3-DH08

180°C

25 mm Ø 0.02 mm-60 °C

–+180 °C

2 m2-5 1) 11 6)

5326025

0-11 2) 0-15.5 7)

0-22 3) 0.5-9.3 8)

0-30 4)

0-38 5)

LL3-DH09

130°C

25 mm Ø 0.02 mm-60 °C

–+130 °C

2 m70 1) 220 6)

5326030

230 2) 90 7)

370 3) 70 8)

750 4)

800 5)

LL3-DH10

250°C

25 mm Ø 0.02 mm-20 °C

–+250 °C

3 m

4-11 1) 3.5-18 6)

5326023

3-18 2) 4-18 7)

3-21 3) 4-15 8)

2-24 4)

2-26 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 60: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

6 0 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Heat-resistant Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-DH11

250°C

25 mm Ø 0.02 mm-20 °C

–+250 °C

2 m

8-19 1) 7.5-24 6)

5326024

6-29 2) 7.5-24 7)

4-34 3) 9-24 8)

3-39 4)

2-42 5)

LL3-DV06 M6

105°C

25 mm Ø 0.015 mm-40 °C

–+105 °C

2 m30 1) 47 6)

5322550

130 2) 12 7)

210 3) 12 8)

450 4)

800 5)

LL3-DW01**M6

200°C

25 mm Ø 0.02 mm-40 °C

–+200 °C

1 m

20 1) –

5315234

50 2) –

95 3) –

150 4)

400 5)

LL3-DW01-2** M6

200°C

25 mm Ø 0.02 mm-40 °C

–+200 °C

2 m

20 1) –

5324789

50 2) –

95 3) –

150 4)

400 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. ** Humidity/level detection only in conjunction with WLL180T-P474 IR version. Mounting material included.

Page 61: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

6 1F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Heat-resistantThrough-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TH01 M4

100°C

Suitable for tip adapters

25 mm Ø 0.2 mm-40 °C

–+100 °C

2 m55 1) 305 6)

5308064

180 2) 125 7)

320 3) 50 8)

680 4)

1000 5)

LL3-TH02 M4

180°C

35 mm Ø 0.5 mm-40 °C

–+180 °C

2 m230 1) 620 6)

5308065

700 2) 255 7)

1300 3) 125 8)

2700 4)

4000 5)

LL3-TH07

200°C

50 mm Ø 0.1 mm-60 °C

–+200 °C

2 m

18 1) –

5325977

30 2) 23 7)

120 3) –

220 4)

420 5)

LL3-TH08

350°C

25 mm Ø 0.04 mm-30 °C

–+350 °C

2 m

150 1) 350 6)

5325978

480 2) 140 7)

790 3) 240 8)

1500 4)

1600 5)

LL3-TH09

350°C

25 mm Ø 0.04 mm-30 °C

–+350 °C

2 m

140 1) 350 6)

5325979

460 2) 140 7)

700 3) 240 8)

1400 4)

1500 5)

LL3-TH10

200°C

10 mm Ø 0.02 mm-60 °C

–+200 °C

2 m

50 1) 130 6)

5325970

180 2) 50 7)

300 3) 80 8)

600 4)

640 5)

LL3-TH11

200°C

25 mm Ø 0.04 mm-60 °C

–+200 °C

1 m

130 1) 320 6)

5325971

400 2) 130 7)

700 3) 200 8)

1400 4)

1500 5)

LL3-TH12

200°C

25 mm Ø 0.12 mm-60 °C

–+200 °C

2 m100 1) 250 6)

5325972

330 2) 100 7)

570 3) 170 8)

1100 4)

1200 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Fiber-optic through-beam systems

Page 62: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

6 2 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Heat-resistant Through-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TH13

200°C

25 mm Ø 0.12 mm-60 °C

–+200 °C

2 m100 1) 250 6)

5325973

330 2) 100 7)

570 3) 170 8)

1100 4)

1200 5)

LL3-TH14 200°C

25 mm Ø 0.12 mm-60 °C

–+200 °C

2 m100 1) 250 6)

5325974

330 2) 100 7)

570 3) 170 8)

1100 4)

1200 5)

LL3-TH15

200°C

25 mm Ø 0.16 mm-60 °C

–+200 °C

2 m90 1) 170 6)

5325975

290 2) 75 7)

480 3) 110 8)

970 4)

1000 5)

LL3-TH16

200°C

25 mm Ø 0.16 mm-60 °C

–+200 °C

2 m90 1) 170 6)

5325976

290 2) 75 7)

480 3) 110 8)

970 4)

1000 5)

LL3-TH17

130°C

25 mm Ø 0.06 mm-60 °C

–+130 °C

2 m230 1) 600 6)

5325967

690 2) 250 7)

1100 3) 400 8)

2300 4)

2400 5)

LL3-TS22M

105°C

10 mm Ø 0.05 mm-40 °C

–+105 °C

2 m220 1) 625 6)

5325968

760 2) –

1500 3) –

2900 4)

4000 5)

LL3-TV06 M4

105°C

25 mm Ø 0.4 mm-40 °C

–+105 °C

2 m180 1) 350 6)

5322547

550 2) 150 7)

900 3) 150 8)

2100 4)

3500 5)

LL3-TW01 M4

200°C

25 mm Ø 0.4 mm-40 °C

–+200 °C

1 m

80 1) –

5315233

230 2) –

350 3) –

560 4)

980 5)

LL3-TW01-2M4

200°C

25 mm Ø 0.4 mm-40 °C

–+200 °C

2 m

80 1) –

5321306

230 2) –

350 3) –

560 4)

980 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 63: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

6 3F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Heat-resistant

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Page 64: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

6 4 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

oil/chemical resistant Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

oil/chemical resistant

Applications in areas involving frequent cleaning or use of chemicals require a solution with durable fibers. Fibers with a PTFE sheath are ideal for almost every environment.

Fiber-optic proximity systems

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DY01

60 mm Ø 0.02 mm-40 °C

–+100 °C

2 m

100 1) 50 6)

5308093

180 2) 27 7)

200 3) 12 8)

150 4)

280 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Detection of meat products in the food industry Wafer detection in wet process

Page 65: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

6 5F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

oil/chemical resistantThrough-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TY01

60 mm Ø 0.3 mm-40 °C

–+70 °C

2 m

400 1) 2000 6)

5308066

1200 2) 415 7)

2100 3) 390 8)

4000 4)

4000 5)

LL3-TY02

60 mm Ø 0.3 mm-40 °C

–+70 °C

2 m

300 1) 620 6)

5308067

1000 2) 225 7)

1300 3) 210 8)

3000 4)

4000 5)

LL3-TY03

20 mm Ø 0.3 mm-55 °C

–+70 °C

2 m460 1) 1000 6)

5325982

1400 2) 350 7)

2500 3) 450 8)

4000 4)

4000 5)

LL3-TY04

30 mm Ø 0.3 mm-40 °C

–+115 °C

2 m740 1) 2200 6)

5325981

2400 2) 800 7)

3000 3) 1300 8)

4000 4)

4000 5)

LL3-TY05

25 mm Ø 4 mm0 °C

–+60 °C

2 m850 1) 2200 6)

5325980

2700 2) 800 7)

3000 3) 1300 8)

4000 4)

4000 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Fiber-optic through-beam systems

Page 66: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

6 6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

liquid level Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Detection of liquids

A variety of fiber optic solutions are available for detecting liquids and liquid levels. Liquid levels can be detected by immersion or tube mounting of a sender/receiver system. Special fibers are available for leak detection.

Fiber-optic proximity systems

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DF02-S01

30 mm –-40 °C

–+105 °C

2 m– –

5321924

– –

– –

–1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Non-contact level detection using LL3-TW01 (in conjunction with IR sensor)

Level detection through immersion using LL3-DF02

Detection of an adhesive strip (humidity detection) using LL3-DW01 and WLL180T IR

Level detection on a pipe (LL3-DF07)

Leak detection (LL3-DW02)

Page 67: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

6 7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

liquid levelProximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DF04

10 mm –-40 °C

–+100 °C

2 m– –

5326035

– –

– –

LL3-DF05

10 mm –-40 °C

–+100 °C

2 m– –

5326034

– –

– –

LL3-DF07

10 mm –-40 °C

–+70 °C

2 m– –

5326033

– –

– –

LL3-DW01**M6

200°C

25 mm Ø 0.02 mm-40 °C

–+200 °C

1 m

20 1) –

5315234

50 2) –

95 3) –

150 4)

400 5)

LL3-DW01-2** M6

200°C

25 mm Ø 0.02 mm-40 °C

–+200 °C

2 m

20 1) –

5324789

50 2) –

95 3) –

150 4)

400 5)

LL3-DW02

20 mm Ø 4 mm-20 °C

–+50 °C

2 m– –

5325608

– –

– –

–1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. ** Humidity/level detection only in conjunction with WLL180T-P474 IR version. Mounting material included.

Page 68: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

6 8 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

liquid level Through-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TF01

20 mm Ø 4 mm-20 °C

–+60 °C

2 m

– –

5324242

– –

– –

LL3-TW01**M4

200°C

25 mm Ø 0.4 mm-40 °C

–+200 °C

1 m

80 1) –

5315233

230 2) –

350 3) –

560 4)

980 5)

LL3-TW01-2**M4

200°C

25 mm Ø 0.4 mm-40 °C

–+200 °C

2 m

80 1) –

5321306

230 2) –

350 3) –

560 4)

980 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. ** Humidity/level detection only in conjunction with WLL180T-P474 IR version. Mounting material included.

Fiber-optic through-beam systems

Page 69: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

6 9F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

liquid level

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Page 70: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

7 0 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

lCDs / transparent objects / semiconductors Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

lCDs/transparent objects/semiconductorsFibers with V-optics are ideal for detecting wafers and glass substrates. They are specially designed to block out background influences.

Fiber-optic proximity systems

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DC03

25 mm Ø 0.3 mm-40 °C

–+60 °C

2 m12-60 1) 7-80 6)

5326020

10-75 2) 10-60 7)

5-85 3) 10-60 8)

3-150 4)

2-280 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Indexing with wafers Detection of glass panes, e.g., with LL3-DC38 Notch detection

Safe detection of substrates, even in a slanted position LL3-DC39 does not have a blind zone. The substrate can be detected at a distance of 0 mm.

Notch detection, e.g., with LL3-DR09

Page 71: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

7 1F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

lCDs / transparent objects / semiconductorsProximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DC04

4 mm Ø 4 mm0 °C

–+70 °C

2 m4-18 1) 1-20 6)

5326018

0-31 2) 1-20 7)

0-34 3) 4-15 8)

0-38 4)

0-38 5)

LL3-DC05

25 mm Ø 25 mm0 °C

–+70 °C

2 m9-18 1) 5-22 6)

5326016

7-29 2) 5-22 7)

5-35 3) 6-25 8)

4-40 4)

3-43 5)

LL3-DC06

4 mm Ø 4 mm0 °C

–+70 °C

2 m4-15 1) 2-15 6)

5326017

2-22 2) 2-15 7)

0-23 3) 3-10 8)

0-25 4)

0-25 5)

LL3-DC07

10 mm Ø 0.06 mm-40 °C

–+60 °C

2 m7-8 1) 5-10 6)

5326019

4-12 2) 7-8 7)

4-14 3) 7-8 8)

2-16 4)

2-18 5)

LL3-DC08

1 mm Ø 0.3 mm-20 °C

–+60 °C

2 m1-2 1) 1-4.5 6)

5326029

1-4 2) 1-2.5 7)

1-6 3) 1-2.5 8)

0-9 4)

0-10 5)

LL3-DC09

10 mm Ø 0.02 mm-40 °C

–+70 °C

2 m6-8 1) 5-8 6)

5326028

6-10 2) 5-8 7)

5-11 3) 5-8 8)

4-13 4)

0-17 5)

LL3-DC38

10 mm Ø 0.02 mm-40 °C

–+50 °C

2 m6 1) 4-7 6)

5322472

6 2) 4-7 7)

6 3) 4-6 8)

1-10 4)

0-15 5)

LL3-DC39

10 mm Ø 0.02 mm-40 °C

–+50 °C

2 m– 0-5 6)

5322513

0-4 2) 0-4 7)

0-4 3) 0-4 8)

0-4 4)

0-4 5)

LL3-DH06

300°C

25 mm Ø 0.02 mm-30 °C

–+300 °C

2 m

3-5 1) 7 6)

5326026

0-10 2) 0.3-10.5 7)

0-19 3) 1.2-9 8)

0-37 4)

0-43 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 72: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

7 2 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

lCDs / transparent objects / semiconductors Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DH08

180°C

25 mm Ø 0.02 mm-60 °C

–+180 °C

2 m2-5 1) 11 6)

5326025

0-11 2) 0-15.5 7)

0-22 3) 0.5-9.3 8)

0-30 4)

0-38 5)

LL3-DH10

250°C

25 mm Ø 0.02 mm-20 °C

–+250 °C

2 m

4-11 1) 3.5-18 6)

5326023

3-18 2) 4-18 7)

3-21 3) 4-15 8)

2-24 4)

2-26 5)

LL3-DH11

250°C

25 mm Ø 0.02 mm-20 °C

–+250 °C

2 m

8-19 1) 7.5-24 6)

5326024

6-29 2) 7.5-24 7)

4-34 3) 9-24 8)

3-39 4)

2-42 5)

LL3-DR09

1 mm Ø 0.03 mm-20 °C

–+70 °C

2 m110 1) 300 6)

5325528

345 2) 120 7)

560 3) 80 8)

1100 4)

1190 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 73: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

7 3F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

lCDs / transparent objects / semiconductorsThrough-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TG01

25 mm Ø 0.06 mm-40 °C

–+70 °C

2 m880 1) 2500 6)

5325940

2300 2) 1300 7)

3500 3) 1600 8)

4000 4)

4000 5)

LL3-TG02

1 mm Ø 0.06 mm-40 °C

–+55 °C

2 m580 1) 1100 6)

5325943

1670 2) 450 7)

2400 3) 700 8)

4000 4)

4000 5)

LL3-TG03

25 mm Ø 0.06 mm-40 °C

–+60 °C

2 m570 1) 1000 6)

5325942

1980 2) 450 7)

2400 3) 700 8)

4000 4)

4000 5)

LL3-TG04

10 mm Ø 0.02 mm-40 °C

–+60 °C

2 m100 1) 250 6)

5324499

290 2) 120 7)

500 3) 120 8)

1000 4)

1100 5)

LL3-TR08

1 mm Ø 0.06 mm-40 °C

–+60 °C

2 m160 1) 350 6)

5325984

480 2) 170 7)

800 3) 150 8)

1600 4)

1700 5)

LL3-TR09

1 mm Ø 0.04 mm-40 °C

–+60 °C

2 m360 1) 900 6)

5325985

1200 2) 500 7)

2200 3) 450 8)

4000 4)

4000 5)

LL3-TS22

25 mm Ø 0.05 mm-40 °C

–+70 °C

2 m390 1) 850 6)

5325944

1300 2) –

2600 3) –

4000 4)

4000 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Fiber-optic through-beam systems

Page 74: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

7 4 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

robotics Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

robotics

These special fibers are designed for use in robotic applications involving repeated bending. Even after more than 800,000 bending cycles, transmission is reduced by less than 10 %.

Fiber-optic proximity systems

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll 180tsensing

distance (mm)

Wll 170(t)-2sensing

distance (mm)

part no.

LL3-DC04

4 mm Ø 4 mm0 °C

–+70 °C

2 m4-18 1) 1-20 6)

5326018

0-31 2) 1-20 7)

0-34 3) 4-15 8)

0-38 4)

0-38 5)

LL3-DC06

4 mm Ø 4 mm0 °C

–+70 °C

2 m4-15 1) 2-15 6)

5326017

2-22 2) 2-15 7)

0-23 3) 3-10 8)

0-25 4)

0-25 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Detecting parts in the grabber

Page 75: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

7 5F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

roboticsProximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll 180tsensing

distance (mm)

Wll 170(t)-2sensing

distance (mm)

part no.

LL3-DR01 M6

4 mm Ø 0.015 mm-40 °C

–+70 °C

2 m90 1) 135 6)

5308078

280 2) 50 7)

450 3) 20 8)

880 4)

1350 5)

LL3-DR02 M3

4 mm Ø 0.015 mm-40 °C

–+70 °C

1 m18 1) 22 6)

5308079

50 2) 9 7)

90 3) 3 8)

200 4)

370 5)

LL3-DR03

4 mm Ø 0.015 mm-40 °C

–+70 °C

2 m30 1) 37 6)

5308080

85 2) 13 7)

140 3) 8 8)

300 4)

600 5)

LL3-DR04

4 mm Ø 0.015 mm-40 °C

–+70 °C

1 m

20 1) 25 6)

5308081

70 2) 9 7)

110 3) 3 8)

220 4)

360 5)

LL3-DR05

4 mm Ø 0.015 mm-40 °C

–+70 °C

0.5 m

10 1) 12 6)

5308087

30 2) 4 7)

60 3) 2 8)

140 4)

225 5)

LL3-DR06M4

4 mm Ø 0.015 mm-40 °C

–+70 °C

2 m18 1) 37 6)

5308082

60 2) 11 7)

100 3) 5 8)

220 4)

360 5)

LL3-DR08 M3

4 mm Ø 0.02 mm-40 °C

–+70 °C

2 m8 1) 22 6)

5326037

25 2) 9 7)

46 3) 6 8)

90 4)

98 5)

LL3-DT02

4 mm Ø 0.015 mm-40 °C

–+70 °C

2 m10 1) 9 6)

5308085

30 2) 4 7)

60 3) 2 8)

140 4)

225 5)

LL3-DT04

4 mm Ø 0.015 mm-40 °C

–+70 °C

0.5 m

13 1) 9 6)

5308086

45 2) 4 7)

80 3) 2 8)

140 4)

280 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 76: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

7 6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

robotics Through-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-TR01 M4

Suitable for tip adapters

4 mm Ø 0.3 mm-40 °C

–+70 °C

2 m200 1) 340 6)

5308052

600 2) 125 7)

1000 3) 125 8)

2400 4)

4000 5)

LL3-TR01-05M4

4 mm Ø 0.3 mm-40 °C

–+70 °C

5 m160 1) 120 6)

5322198

450 2) 60 7)

800 3) 60 8)

1900 4)

2800 5)

LL3-TR02 M3

4 mm Ø 0.1 mm-40 °C

–+70 °C

2 m60 1) 115 6)

5308053

175 2) 38 7)

330 3) 23 8)

750 4)

1100 5)

LL3-TR03

4 mm Ø 0.1 mm-40 °C

–+70 °C

1 m60 1) 115 6)

5308054

175 2) 38 7)

330 3) 23 8)

750 4)

1100 5)

LL3-TR03-2

4 mm Ø 0.1 mm-40 °C

–+70 °C

2 m60 1) 115 6)

5308055

175 2) 38 7)

330 3) 23 8)

750 4)

1100 5)

LL3-TR04

4 mm Ø 0.02 mm-40 °C

–+60 °C

0.5 m

5 1) 12 6)

5325918

17 2) 5 7)

28 3) 5 8)

56 4)

60 5)

LL3-TR05

4 mm Ø 0.03 mm-40 °C

–+60 °C

2 m360 1) 1200 6)

5325808

1300 2) 500 7)

2300 3) 750 8)

4000 4)

4000 5)

LL3-TR06

4 mm Ø 0.03 mm-40 °C

–+60 °C

2 m560 1) 1200 6)

5325912

1600 2) 500 7)

2200 3) 750 8)

4000 4)

4000 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Fiber-optic through-beam systems

Page 77: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

7 7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

robotics

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Page 78: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

7 8 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

retro-reflective Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

retro-reflective

Retro-reflective fibers are ideal for detecting transparent objects. The polarizing filter integrated in the LL3-RR01 can even handle shiny surfaces.

Fiber-optic proximity systems

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-RB01

10 mm Ø 0.06 mm-40 °C

–+60 °C

2 m105 1) 220 6)

5326010

190 2) 80 7)

230 3) 65 8)

460 4)

490 5)

LL3-RB02

10 mm Ø 0.06 mm-40 °C

–+60 °C

2 m100 1) 220 6)

5326011

170 2) 80 7)

210 3) 65 8)

430 4)

460 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

LL3-RB01 LL3-RB02 LL3-RR01

Page 79: Sick Fibre Optic Sensors and Fibers

C

8014999/2012-05Subject to change without notice

7 9F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

retro-reflectiveProximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing range

(mm)

Wll170-2sensing range

(mm)

part no.

LL3-RG01

10 mm Ø 0.12 mm-40 °C

–+60 °C

2 m80 1) –

5326012

200 2) –

310 3) –

620 4)

660 5)

LL3-RR01

1 mm Ø 0.3 mm-25 °C

–+55 °C

2 m290 1) 650 6)

5326008

580 2) 250 7)

720 3) 180 8)

1450 4)

1550 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Page 80: Sick Fibre Optic Sensors and Fibers

D

8014999/2012-05Subject to change without notice

8 0 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

tip adapters Through-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name temper-ature

part no. ll model name/sensing range (mm)ll3-tB01 ll3-tB01-10 ll3-tB01-30 ll3-tB02 ll3-tB06

For l

ong

dist

ance

s

LL3-TA01

-40 °C–

+100 °C5308128

3000 1) 1800 1) 1000 1) 3500 1) 3500 1)

1200 2) 700 2) 400 2) 1400 2) 1400 2)

1100 3) 600 3) 200 3) 1200 3) 1200 3)

LL3-TA01S -40 °C

–+100 °C

5326461

3000 1) 1800 1) 1000 1) 3500 1) 3500 1)

1200 2) 700 2) 400 2) 1400 2) 1400 2)

800 3) 500 3) 200 3) 1000 3) 1000 3)

LL3-TA02

-40 °C–

+70 °C5308129

600 1) 360 1) 200 1) 600 1) –

230 2) 130 2) 80 2) 230 2) –

100 3) – – 100 3) –

LL3-TA03

-40 °C–

+350 °C5326462

3500 1) 2100 1) 1200 1) 3500 1) 3500 1)

1400 2) 850 2) 500 2) 1400 2) 1400 2)

1000 3) 600 3) 200 3) 1000 3) 1000 3)

LL3-TA04

-60 °C–

+350 °C5326463

3500 1) 2100 1) 1200 1) 3500 1) 3500 1)

1400 2) 850 2) 500 2) 1400 2) 1400 2)

1000 3) 600 3) 200 3) 1000 3) 1000 3)

LL3-TA05

-60 °C–

+300 °C5326464

500 1) 300 1) 180 1) 500 1) –

200 2) 100 2) 70 2) 200 2) –

– – – 80 3) –1) Red light: 250 µs 2) High speed: 50 µs 3) Green light: 250 µs Mounting material included.

Suitable for WLL170-2 amplifiers

Page 81: Sick Fibre Optic Sensors and Fibers

D

8014999/2012-05Subject to change without notice

8 1F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

tip adaptersThrough-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

tip adapters for through-beam systems

Tip adapters are available for a variety of fibers. They focus the light beam. The sensing range of through-beam fibers can be considerably increased by using tip adapters. The LL3-TA02 and LL3-TA05 models enable an additional 90° deflection.

ll model name/sensing range (mm)ll3-tH01 ll3-tH08 ll3-tH10 ll3-tH11 ll3-tJ01 ll3-tK77 ll3-tr01

3500 1) – – – 1500 1) 3500 1) 3000 1)

1400 2) – – – 600 2) 1400 2) 1200 2)

1200 3) – – – 400 3) 1200 3) 1000 3)

3500 1) – – – 1500 1) 3500 1) 3000 1)

1400 2) – – – 600 2) 1400 2) 1200 2)

1000 3) – – – 400 3) 1100 3) 1100 3)

– – – – 500 1) 600 1) 500 1)

– – – – 200 2) 230 2) 200 2)

– – – – – – –

3500 1) 2100 1) 1500 1) 1500 1) 1500 1) 3500 1) 2500 1)

1400 2) 850 2) 600 2) 600 2) 600 2) 1400 2) 1000 2)

1000 3) 500 3) 300 3) 300 3) 300 3) 1000 3) 700 3)

3500 1) 3500 1) 1500 1) 1500 1) 1500 1) 3500 1) 3500 1)

1400 2) 1400 2) 600 2) 600 2) 600 2) 1400 2) 1400 2)

1000 3) 1000 3) 300 3) 250 3) 250 3) 1000 3) 1100 3)

400 1) 350 1) 300 1) 350 1) 400 1) 400 1) 350 1)

150 2) 140 2) 120 2) 140 2) 160 2) 160 2) 140 2)

– – – – – – –1) Red light: 250 µs 2) High speed: 50 µs 3) Green light: 250 µs Mounting material included.

Page 82: Sick Fibre Optic Sensors and Fibers

D

8014999/2012-05Subject to change without notice

8 2 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

tip adapters Through-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name temper-ature

part no. ll model name/sensing range (mm)ll3-tB01 ll3-tB01-10 ll3-tB01-30 ll3-tB02 ll3-tB06

For l

ong

dist

ance

s

LL3-TA01

-40 °C–

+100 °C5308128

800 1) 720 1) 570 1) 1800 1) 1500 1)

2500 2) 2250 2) 1800 2) 4000 2) 4000 2)

4000 3) 3600 3) 2880 3) 4000 3) 4000 3)

4000 4) 3600 4) 2880 4) 4000 4) 4000 4)

4000 5) 3600 5) 2880 5) 4000 5) 4000 5)

LL3-TA01S -40 °C

–+100 °C

5326461

800 1) 720 1) 570 1) 1800 1) 1500 1)

2500 2) 2250 2) 1800 2) 4000 2) 4000 2)

4000 3) 3600 3) 2880 3) 4000 3) 4000 3)

4000 4) 3600 4) 2880 4) 4000 4) 4000 4)

4000 5) 3600 5) 2880 5) 4000 5) 4000 5)

LL3-TA02

-40 °C–

+70 °C5308129

200 1) 180 1) 150 1) 300 1) –

650 2) 585 2) 460 2) 1000 2) –

1200 3) 1080 3) 860 3) 1800 3) –

2500 4) 2250 4) 1800 4) 3500 4) –

3600 5) 3240 5) 2600 5) 4000 5) –

LL3-TA03

-40 °C–

+350 °C5326462

360 1) 324 1) 260 1) 1200 1) 1200 1)

2000 2) 1800 2) 1440 2) 4000 2) 4000 2)

4000 3) 3600 3) 2880 3) 4000 3) 4000 3)

4000 4) 3600 4) 2880 4) 4000 4) 4000 4)

4000 5) 3600 5) 2880 5) 4000 5) 4000 5)

LL3-TA04

-60 °C–

+350 °C5326463

4000 1) 3600 1) 2880 1) 4000 1) 4000 1)

4000 2) 3600 2) 2880 2) 4000 2) 4000 2)

4000 3) 3600 3) 2880 3) 4000 3) 4000 3)

4000 4) 3600 4) 2880 4) 4000 4) 4000 4)

4000 5) 3600 5) 2880 5) 4000 5) 4000 5)

LL3-TA05

-60 °C–

+300 °C5326464

250 1) 225 1) 180 1) 250 1) –

800 2) 720 2) 570 2) 800 2) –

1200 3) 1080 3) 860 3) 1200 3) –

2400 4) 2160 4) 1700 4) 2400 4) –

4000 5) 3600 5) 2880 5) 4000 5) –1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms Mounting material included.

Suitable for WLL180T amplifiers

Page 83: Sick Fibre Optic Sensors and Fibers

D

8014999/2012-05Subject to change without notice

8 3F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

tip adaptersThrough-beam systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

ll model name/sensing range (mm)ll3-tH01 ll3-tH08 ll3-tH10 ll3-tH11 ll3-tJ01 ll3-tK77 ll3-tr01

500 1) – – – 750 1) 2000 1) 1800 1)

1400 2) – – – 2000 2) 4000 2) 4000 2)

2500 3) – – – 2000 3) 4000 3) 4000 3)

4000 4) – – – 2000 4) 4000 4) 4000 4)

4000 5) – – – 2000 5) 4000 5) 4000 5)

500 1) – – – 650 1) 2000 1) 1800 1)

1400 2) – – – 2000 2) 4000 2) 4000 2)

2500 3) – – – 2000 3) 4000 3) 4000 3)

4000 4) – – – 2000 4) 4000 4) 4000 4)

4000 5) – – – 2000 5) 4000 5) 4000 5)

– – – – 200 1) 300 1) 200 1)

– – – – 600 2) 950 2) 900 2)

– – – – 950 3) 1800 3) 1500 3)

– – – – 1900 4) 3500 4) 3300 4)

– – – – 4000 5) 4000 5) 4000 5)

1200 1) 800 1) 750 1) 1000 1) 600 1) 600 1) 800 1)

2000 2) 2000 2) 2000 2) 2000 2) 2000 2) 2000 2) 2000 2)

4000 3) 4000 3) 2000 3) 2000 3) 2000 3) 4000 3) 4000 3)

4000 4) 4000 4) 2000 4) 2000 4) 2000 4) 4000 4) 4000 4)

4000 5) 4000 5) 2000 5) 2000 5) 2000 5) 4000 5) 4000 5)

4000 1) 4000 1) 2000 1) 2000 1) 2000 1) 4000 1) 4000 1)

4000 2) 4000 2) 2000 2) 2000 2) 2000 2) 4000 2) 4000 2)

4000 3) 4000 3) 2000 3) 2000 3) 2000 3) 4000 3) 4000 3)

4000 4) 4000 4) 2000 4) 2000 4) 2000 4) 4000 4) 4000 4)

4000 5) 4000 5) 2000 5) 2000 5) 2000 5) 4000 5) 4000 5)

160 1) 170 1) 100 1) 150 1) 200 1) 200 1) 160 1)

450 2) 550 2) 300 2) 400 2) 600 2) 600 2) 550 2)

800 3) 800 3) 600 3) 700 3) 950 3) 950 3) 850 3)

1500 4) 1600 4) 1100 4) 1400 4) 1900 4) 1900 4) 1700 4)

4000 5) 4000 5) 2000 5) 4000 5) 4000 5) 4000 5) 4000 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms Mounting material included.

Page 84: Sick Fibre Optic Sensors and Fibers

D

8014999/2012-05Subject to change without notice

8 4 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

tip adapters Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name tempera-ture

part no. light spot size Focal length [mm]ll3-DK21 ll3-Dt01 ll3-DM02

LL3-DA01

- 40 °C–

+70 °C5308127 Ø 0.2 mm Ø 0.4 mm – 6

LL3-DA02 - 40 °C

–+ 70 °C

5308130 Ø 1.2 mm Ø 1.4 mm – 15

LL3-DA03 - 20 °C

–+ 60 °C

5326465 Ø 0.2 mm Ø 0.4 mm – 7

LL3-DA04

- 40 °C–

+ 70 °C5326466 Ø 0.3 mm Ø 0.5 mm – 7.5

LL3-DA05

- 40 °C–

+ 70 °C5326467 – – Ø 0.5 mm 6

LL3-DA06

- 40 °C–

+ 70 °C5326468 – –

Ø 0.7 mm–

0.85 mm~ 20

LL3-DA07

- 40 °C–

+ 70 °C5326469 – –

Ø 0.5 mm–

0.8 mm~ 14

Suitable for proximity systems

Page 85: Sick Fibre Optic Sensors and Fibers

D

8014999/2012-05Subject to change without notice

8 5F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

tip adaptersProximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

tip adapters for proximity systems

Tip adapters are available for a variety of fibers. They focus the light beam even more. For proximity style fibers, a very small light spot is created for detecting fine and small objects. The LL3-DA07 tip adapter deflects the light by 90°.

Page 86: Sick Fibre Optic Sensors and Fibers

E

8014999/2012-05Subject to change without notice

8 6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Amplifiers

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Fits flexibly into the narrowest corners

When installation space is extremely limited or the objects to be detected are tiny, fiber-optic sensors are the ideal solution. If it is necessary for even higher requirements to be fulfilled, such as sensing range, temperature resistance, material durability or a flexible mounting process, the intelligent combination of sensors and fibers can provide the perfect solution. A wide range of fibers with application-specific optical heads ensure that every need is met.

Your benefits • Reliable and accurate detection

of the smallest objects thanks to innovative, microcontroller-supported electronics

• EMC, high temperature tolerance and resistance to chemicals, as the evaluation electronics are mounted separately from the fiber-optic head

• Space-saving mounting even in confined spaces

• Multiple setting options provide solutions for practically any application

• Lightweight, suitable for use on a robot arm

• Universal application possibilities due to wide range of fibers

Page 87: Sick Fibre Optic Sensors and Fibers

E

8014999/2012-05Subject to change without notice

8 7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Amplifiers

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Fiber-optic sensors and fibers

product family overview 88

Wll170-2Versatility for standard applications

90

Wll180tA global leader when it comes to sensing range and performance

96

Page 88: Sick Fibre Optic Sensors and Fibers

E

8014999/2012-05Subject to change without notice

8 8 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Amplifiers/product family overview

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

product family overview

the versatile Wll170-2

WLL170-2 WLL180T

Versatility for standard applications A global leader when it comes to sensing range and performance

technical data overviewHousing material Plastic Plastic

type of light Visible red/green light Visible red light/infraredEnclosure rating IP 66 IP 50

Adjustment Potentiometer, 10 revolutions, teach-in button, cable Teach-in button, cable, increment button +/- manualresponse time ≤ 0.25 ms, ≤ 50 µs ≤ 2 ms, ≤ 8 ms, ≤ 16 µs, ≤ 70 µs, ≤ 250 µs

sensing range button 160 mm 1400 mmsensing range, through-beam 700 mm 20 m

output signal switching device Light/dark-switching Light/dark-switchingindicator LED Display

At a glance

• Rapid response time (50 μs) • Switching threshold adjustment via

potentiometer, or teach-in via button or cable • 4 different teach-in modes • Simple installation • Red or green LED emitter

• Selectable response time up to 16 µs • Sensing range up to 20 m, sensing distance

up to 1400 mm • Bus-compatible with anti-interference • 2 x 4-digit digital display • Adjustable hysteresis • Rotatable display • High-resolution signal processing • Programmable time delays

Detailed information -- 90–95 -- 96–100

Easy to operate fiber-optic sensor. Simple adjustment via potentiometer or teach-in button.

The devices are optimized for the individual applications: • Standard applications • High speed applications (50 μs) • Easy contrast detection with green LED emitter

Page 89: Sick Fibre Optic Sensors and Fibers

E

8014999/2012-05Subject to change without notice

8 9F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Amplifiers/product family overview

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

the high-performance Wll180t

The world's fastest fiber-optic sensor in its class with a 16 µs response time. It reliably detects up to 31,250 workpieces per second.

• Easy reading guaranteed: The 7-segment display can be turned upside down in difficult installation conditions

• Up to 16 devices can be synchronized in bus mode. This prevents mutual interference (anti-interference) in the case of closely mounted fiber-optic heads.

The plug/socket design means installation on a mounting rail is extremely easy

Even sensing ranges of up to 20 m can be achieved with the WLL180T and the corresponding fiber. The powerful light beam penetrates particles in the air. Workpieces are detected even under difficult conditions, such as dust, mist or spray.

• All connected WLL180T sensors can be individually set on the device or via the relevant teach-in cable. If all devices should be taught-in simultaneously, this can be done via bus coupling with a single teach-in cable.

• ASC for maintenance-free operation: If, for example, the light intensity is reduced by dust, this is detected and the switching threshold compensates accordingly. The switching threshold is automatically recalibrated after the optics are cleaned.

• Adjustable hysteresis: The hysteresis can be adjusted from 1 % to 40 %. This enables flexible settings for detection of complex objects.

• Anti-blooming function to prevent overload.

The copy function simplifies commissioning. All settings are copied to the other bus devices at the touch of a button.

Page 90: Sick Fibre Optic Sensors and Fibers

E

8014999/2012-05Subject to change without notice

9 0 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Wll170-2 At a glance

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

product descriptionThis fiber-optic sensor with its simple operating system is ideal for standard applications as well as when rapid response times are crucial. WLL170(T) variants which are optimized for diverse specific applications, such as detection of the smallest of objects, color marks or transparent objects, are available: The WLL170T-2 with teach-in featuring automatic switching threshold adjustment via button or cable, or the WLL170-2 with manual switching threshold

adjustment via potentiometer. Both models are available in a high-speed version with a switching frequency of 10 kHz for extremely fast response times. For optimum detection of color contrasts, you can choose between devices with a red or green LED emitter. Detection tasks are handled securely and reliably using the LL3 series of fibers.

At a glance • Rapid response time (50 μs) • Switching threshold adjustment via

potentiometer, or teach-in via button or cable

• 4 different teach-in modes • Simple installation • Red or green LED emitter

Your Benefits • Reliable, rapid process detection • Low installation costs due to short

commissioning time • The optimum setting for every

application thanks to a variety of teach-in modes

• Emitted light ideal for color or contrast detection

• Easy to operate fiber-optic sensor thanks to setting via potentiometer and switch

Versatility for standard applications

Additional informationDetailed technical data. . . . . . . 91 – 92

Ordering information. . . . . . . . . 92 – 93

Dimensional drawing . . . . . . . . . . . . 93

Adjustments . . . . . . . . . . . . . . . . . . . 94

Function diagram . . . . . . . . . . . . . . . 94

Connection type and diagram . . . . . 95

Recommended accessories . . . . . . 104

Page 91: Sick Fibre Optic Sensors and Fibers

E

8014999/2012-05Subject to change without notice

9 1F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Wll170-2Technical data

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Detailed technical dataWll170-2 Wll170t-2

sensor type Fiber-optic sensor

Dimensions (W x H x D) 10.5 mm x 35.5 mm x 83.7 mm

Max. sensing range 0 m ... 4 m, through-beam system 1) 0 m ... 3.50 m, through-beam system 1)

sensing range 0 m ... 0.16 m, proximity system 2)

0 m ... 0.70 m, through-beam system 3)

(depends on type)

0 m ... 0.16 m, proximity system 2)

0 m ... 0.70 m, through-beam system 3)

Housing design (light emission) Cuboid

light sender 4) LED

type of light Visible red/green light (depends on type)

WavelengthVisible red light

Green light

660 nm 660 nm

sensitivity control Potentiometer, 10 rotations 5) Teach-in button/teach-in button,Cable (depends on type)

Adjustment of operating distance – Teach-in button/teach-in button,Cable (depends on type)

teach-in – Yes

time type Off delay

Delay time Can be selected via sliding switch: ≤ 40 ms

Display LED1) LL3-TB02 and tip adapter LL3-TA01.2) Object with 90 % remission (based on DIN 5033 white standard), sensing distance depends on fibers.3) LL3-TB01.4)Average service life 100,000 h at TU = +25 °C.5) Scale: 270°.

Mechanics/electronicsWll170-2 Wll170t-2

supply voltage 1) 10 V DC ... 30 V DC

residual ripple 2) 10 %

power consumption 3) ≤ 30 mA

output signal switching device PNP, light/dark-switching, can be selected via light/dark switch, open collectorNPN, light/dark-switching, can be selected via light/dark switch, open collector(depends on type)

output current imax.≤ 100 mA

response time2,000 Hz

10,000 Hz

≤ 0.25 ms 4)

≤ 50 µs 4)

switching frequency≤ 0.25 ms

< 50 µs

2,000 Hz 5)

10,000 Hz 5)

Aperture angle 6) Approx. 65°

Connection type Cable, 3-wire, 2 m, PVC, 0.2 mm², 3.8 mm 7)

Plug M8, 3-pinPlug M8, 4-pin(depends on type)

Cable, 4-wire, 2 m, PVC, 0.2 mm² 7)

Cable, 4-wire, 5 m, PVC, 0.2 mm² 7)

Plug M8, 3-pinPlug M8, 4-pin(depends on type)

Circuit protection A 8), B 9), C 10), D 11)

protection class III

Housing material ABS/PC ABS

Page 92: Sick Fibre Optic Sensors and Fibers

E

8014999/2012-05Subject to change without notice

9 2 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Wll170-2 Ordering information

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Wll170-2 Wll170t-2

Enclosure rating 12) IP 66

Ambient temperature, operation –25 °C ... +55 °C

Ambient temperature, storage –40 °C ... +70 °C1) Limit values.2) Must not exceed or fall short of UV tolerances.3) Without load.4) Signal propagation time with ohmic load.5) With light/dark ratio 1:1.6) See LL3 fiber data.7) Do not bend below 0 °C.8) A = UV connections reverse polarity protected.9) B = Inputs and output reverse polarity protected.10) C = Suppression of interfering pulses.11) D = Outputs overcurrent and short-circuit protected.12) With correctly attached LL3 fibers and closed protection hood.

ordering information

WLL170-2 • Adjustment: Potentiometer, 10 revolutions (scale: 270°)

type of light response time Max. sensing range 1)

switching type Connection Model name part no.

Visible red light

≤ 0.25 ms

0 mm ... 4,000 mm,

through-beam system

PNP

Cable, 3-wire, 2 m WLL170-2P132 6029511

Plug M8, 3-pin WLL170-2P330 6029513

Plug M8, 4-pin WLL170-2P430 6029514

NPN

Cable, 3-wire, 2 m WLL170-2N132 6029515

Plug M8, 3-pin WLL170-2N330 6029517

Plug M8, 4-pin WLL170-2N430 6029518

< 50 µs

0 mm ... 1,600 mm,

through-beam system

PNP

Cable, 3-wire, 2 m WLL170-2P162 6029527

Plug M8, 3-pin WLL170-2P360 6029529

Plug M8, 4-pin WLL170-2P460 6029530

NPN

Cable, 3-wire, 2 m WLL170-2N162 6029531

Plug M8, 3-pin WLL170-2N360 6029533

Plug M8, 4-pin WLL170-2N460 6029534

Green light ≤ 0.25 ms

0 mm ... 1,700 mm,

through-beam system

PNP

Cable, 3-wire, 2 m WLL170-2P192 6029519

Plug M8, 3-pin WLL170-2P390 6029521

Plug M8, 4-pin WLL170-2P490 6029522

NPN

Cable, 3-wire, 2 m WLL170-2N192 6029523

Plug M8, 3-pin WLL170-2N390 6029525

Plug M8, 4-pin WLL170-2N490 60295261) LL3-TB02 and tip adapter LL3-TA01.

Page 93: Sick Fibre Optic Sensors and Fibers

E

8014999/2012-05Subject to change without notice

9 3F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Wll170-2Dimensional drawings

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

WLL170T-2type of light response

timeMax. sensing

range 1)Adjustment switching

typeConnection Model name part no.

Visible red light

≤ 0.25 ms

0 mm ... 3,500 mm,

through-beam system

Teach-in buttonPNP Plug M8, 3-pin WLL170T-2P330 6033949

NPN Plug M8, 3-pin WLL170T-2N330 6033952

Teach-in button, cable

PNP

Cable, 4-wire, 2 m WLL170T-2P132 6033948

Cable, 4-wire, 5 m WLL170T-2P135 6036328

Plug M8, 4-pin WLL170T-2P430 6033950

NPNCable, 4-wire, 2 m WLL170T-2N132 6033951

Plug M8, 4-pin WLL170T-2N430 6033953

< 50 µs

0 mm ... 1,500 mm,

through-beam system

Teach-in buttonPNP Plug M8, 3-pin WLL170T-2P360 6033964

NPN Plug M8, 3-pin WLL170T-2N360 6033961

Teach-in button, cable

PNPCable, 4-wire, 2 m WLL170T-2P162 6033963

Plug M8, 4-pin WLL170T-2P460 6033965

NPNCable, 4-wire, 2 m WLL170T-2N162 6033960

Plug M8, 4-pin WLL170T-2N460 6033962

Green light ≤ 0.25 ms

0 mm ... 1,600 mm,

through-beam system

Teach-in buttonPNP Plug M8, 3-pin WLL170T-2P390 6033955

NPN Plug M8, 3-pin WLL170T-2N390 6033958

Teach-in button, cable

PNPCable, 4-wire, 2 m WLL170T-2P192 6033954

Plug M8, 4-pin WLL170T-2P490 6033956

NPNCable, 4-wire, 2 m WLL170T-2N192 6033957

Plug M8, 4-pin WLL170T-2N490 60339591) LL3-TB02 and tip adapter LL3-TA01.

Dimensional drawingsWLL170-2

84,1

3

9 9,5 8

72,65 6,5

2,3

10,5

41

,1

11,5

10,7

8

4,3

35

,55

,6

18,9

ø 4,2

9

36,6

10 7

ø 3,2

~180°

12,51 4

2

3

5 5

1 LED emitter, installation of LL3 fibers (emitter fiber)2 Receiver, installation of LL3 fibers (receiver fiber)3 Hinged protection hood4 Mounting bracket, included5 Connection

WLL170T-2

89 9,5

3

83,7

736,6

79,1

810

,7

35

,5

41

,15

,6

9 10

11,5

10,5

4,3

1

4

3

52

1 LED emitter, installation of LL3 fibers (emitter fiber)2 Receiver, installation of LL3 fibers (receiver fiber)3 Hinged protection hood4 Mounting bracket, included5 Connection

Dimensions in mm

Page 94: Sick Fibre Optic Sensors and Fibers

E

8014999/2012-05Subject to change without notice

9 4 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Wll170-2 Adjustments/function diagram

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

AdjustmentsWLL170-2

Min MaxSENS.

OFF DLY

L.ON

OFF

D.ON

6

7

8

9

10

11

12

6 Indicating pin correctly inserted LL3 fiber7 LED indicator orange: Lights up when output signal switching device is active8 Receive indicator green: Lights up when light received < 0.9 or >1.1

(switching threshold = 1)9 Sensitivity scale 270°ß Sensitivity control (10 revolutions)à OFF delay selector switch: "OFF DLY" (on)/"OFF" (off), 40 ms fixedá Selector switch: "L.ON" (light-switching/"D.ON" (dark-switching)

WLL170T-2

TEACH

DLY

OFF

D. ON

L. ON

SET

RUN

OFF

6

7

8

9

10

11

12

6 Indicating pin correctly inserted LL3 fiber7 LED indicator orange: Lights up when output signal switching device is active8 Receive indicator green: Lights up when light received < 0.9 or >1.1

(switching threshold = 1)9 Teach-in buttonß Operating mode selector switch:"SET" (teach-in mode)/"RUN" (sensor mode)à OFF delay selector switch: "OFF DLY" (on)/"OFF" (off), 40 ms fixedá Selector switch: "L.ON" (light-switching/"D.ON" (dark-switching)

Function diagramWLL170-2

� WLL 170-2

Orange LED display: lights up if switching output

Q is active. Dependent on setting of light/

dark selector switch.

Green LED display: lights up if light received

is < 0.9 or > 1.1 (based on the switching

threshold Q, switching threshold = 1).

1.1

1.0

0.9

ONOFF

ONOFF

ONOFF

ONOFF

ONOFF

Light received > 1.1

Switching output Q (light-switching)

Indicator LED, orange

Indicator LED, green

Light received < 0.9

t 40 msOFF

Indicator LED, orange

Switching threshold (1)

Switching output Q (dark-switching)

WLL170T-21.1

1.0

0.9

ONOFF

ONOFF

ONOFF

ONOFF

ONOFF

Light received > 1.1

Supply connection Q (light-switching)

Orange LED display

Green LED display

Light received < 0.9

t 40 msOFF

Orange LED display

Switching threshold (1)

Supply connection Q (dark-switching)

WLL170T-2 in sensor mode

Operating mode selector switch in RUN mode (after setting the switching threshold by means of Teach-in.

Orange LED display: lights up if supply connec-tion Q is active. Dependent on setting of light/dark-selector switch.

Green LED display: lights up if light received is < 0.9 or > 1.1 (based on the switching threshold Q, switching threshold = 1).

Page 95: Sick Fibre Optic Sensors and Fibers

E

8014999/2012-05Subject to change without notice

9 5F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Wll170-2Connection

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Connection type and diagramWLL170-2 cable, 3-wire

brn

blu

blk

L+

M

Q

WLL170-2, WLL170T-2 plug M8, 3-pin

1L+

M

Q

3

4

WLL170-2 plug M8, 4-pin

1L+

M

Q

NC

3

4

2

WLL170T-2 cable, 4-wire

brn

blu

blk

L+

M

Q

ETwht

WLL170T-2 plug M8, 4-pin

1L+

M

Q

ET

3

4

2

Page 96: Sick Fibre Optic Sensors and Fibers

E

8014999/2012-05Subject to change without notice

9 6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Wll180t

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

At a glance

product descriptionThe WLL180T provides the world’s fastest response time - only 16 μs. At the same time, the sensor offers maximum values for sensing range and operating reserve due to its high light intensity and resolution. This considerably increases process reliability when used in dusty or moist environments. Commissioning is simple – either via the external teach-in input or directly on the unit. All programming steps, status displays, and target and actual values are shown on two four-digit displays. The WLL180T

can be operated either as a stand-alone sensor or in a bus configuration, depending on your requirements. In a bus configuration, several sensors are networked via an internal bus, enabling the settings on one WLL180T to be copied to all other devices on the bus. Mutual interference by fiber-optic heads installed in close proximity is prevented by the integrated anti-interference logic.

At a glance • Selectable response time up to 16 µs • Sensing range up to 20 m, sensing

distance up to 1.40 m • Bus-compatible with anti-interference • 2 x 4-digit digital display

• Adjustable hysteresis • Rotatable display • High-resolution signal processing • Programmable time delays

Your Benefits • Reliable, rapid process detection • Workpieces are detected reliably

even under the most difficult ambient conditions, such as dust, spray or mist

• Thanks to bus communication, closely mounted fiber-optic heads do not influence each other

• Easy monitoring of process parameters • Hysteresis can be adapted to suit the

application, e.g., when detecting tiny or transparent objects

• Easy-to-read display, even under difficult installation conditions

• Tiny objects can be detected due to the high-resolution signal processing

• Time delays can be adjusted individually to suit the application

A global leader when it comes to sensing range and performance

Additional informationDetailed technical data. . . . . . . 97 – 98

Ordering information. . . . . . . . . 98 – 99

Dimensional drawing . . . . . . . . . . . . 99

Adjustments . . . . . . . . . . . . . . . . . . 100

Connection type and diagram . . . . 100

Recommended accessories . . . . . . 104

Page 97: Sick Fibre Optic Sensors and Fibers

E

8014999/2012-05Subject to change without notice

9 7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Wll180t

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Technical data

Detailed technical dataVisible red light infrared light 5)

sensor type Fiber-optic sensor

Device type Stand-aloneBase unit 1)

Expansion unit(depends on type)

Stand-alone

Dimensions (W x H x D) 10.5 mm x 34.6 mm x 71.9 mm

Max. sensing range 0 m ... 20 m, through-beam system 2) 0 m ... 1 m, through-beam system 2)

sensing range 0 m ... 1.40 m, proximity system 3)

0 m ... 20 m, through-beam system 2)

0 m ... 0.40 m, proximity system 3) 0 m ... 0.85 m, through-beam system 2)

Housing design (light emission) Cuboid

light sender 4) LED

type of light Visible red light Infrared light

Wavelength 650 nm 1,450 nm

sensitivity control Teach-in button, cable, increment button +/– manual

Adjustment of operating distance Teach-in button, cable, increment button +/– manual

teach-in Menu-controlled

time type Without time delay, off delay, on delay, on and off delay, one-shot

Delay time Programmable: 0 ms … 9,999 ms

indicator Display1) Up to 15 expansion units can be connected.2)Sensing range at response time 8 ms. Sensing range reduction with shorter response time (see tables LL3/WLL180T)3) Object with 90 % remission (based on standard white to DIN 5033). Sensing distance with 8 ms response time. Sensing distance reduction with shorter response time

(see tables LL3/WLL180T).4)Average service life: 100,000 h at TU = +25 °C.5) Only in conjunction with LL3-TW01/LL3-DW01.

Mechanics/electronicsVisible red light infrared light

supply voltage 1) 12 V DC ... 24 V DC

residual ripple 2) ≤ 10%

power consumption 3) ≤ 50 mA

output signal switching device PNP, light/dark-switching, can be selected manually, open collectorNPN, light/dark-switching, can be selected manually, open collector(depends on type)

output current imax.≤ 100 mA

response time 4) ≤ 16 µs, ≤ 70 µs, ≤ 250 µs, ≤ 2 ms, ≤ 8 ms

switching frequency 31.2 kHz, 7.1 kHz, 2 kHz, 250 Hz, 62.5 Hz

Aperture angle 5) Approx. 65°

Connection type 6) Cable, 4-wire, 2 m, PVC, 0.2 mm²Cable, 2-wire, 2 m, PVC, 0.2 mm²Plug M8, 4-pinPlug M8, 3-pin(depends on type)

Plug M8, 4-pin

Circuit protection A 7), B 8), C 9), D 10)

protection class III

Housing material ABS/PC

Page 98: Sick Fibre Optic Sensors and Fibers

E

8014999/2012-05Subject to change without notice

9 8 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Wll180t

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Ordering information

Visible red light infrared light

Enclosure rating 11) IP 50

Ambient temperature, operation 12) –25 °C ... +55 °C–25 °C ... +55 °C(depends on type)

–25 °C ... +55 °C

Ambient temperature, storage –40 °C ... +70 °C1) +/– 10 %.2) Must not exceed or fall short of UV tolerances.3) Without load.4) Can be selected.5) See LL3 fiber data.6) Do not bend below 0 °C.7) A = UV connections reverse polarity protected.8) B = Inputs and output reverse polarity protected.9) C = Suppression of interfering pulses.10) D = Outputs overcurrent and short-circuit protected.11) With correctly attached LL3 fibers and closed protection hood.12) Operating temperature fluctuates according to number of devices connected:

4–8 devices: –25 °C … +50 °C (output current 50 mA) / 9–16 devices: –25 °C … +45 °C (output current 20 mA).

ordering information

Visible red light • type of light: Visible red light • Adjustment: Teach-in button, cable, increment button +/– manual • Max. sensing range: 0 m to 20 m, through-beam system (sensing range at response time 8 ms. Sensing range reduction with shorter

response time [see tables LL3/WLL180T].)

Device type output signal switching device Connection Model name part no.

Stand-alone

PNPCable, 4-wire, 2 m WLL180T-P432 6039093

Plug M8, 4-pin WLL180T-P434 6039095

NPNCable, 4-wire, 2 m WLL180T-N432 6039094

Plug M8, 4-pin WLL180T-N434 6039096

Base unit 1)

PNP

Cable, 4-wire, 2 m WLL180T-M432 6039097

Plug M8, 3-pin WLL180T-M333 6042428

Plug M8, 4-pin WLL180T-M434 6039101

NPNCable, 4-wire, 2 m WLL180T-L432 6039099

Plug M8, 4-pin WLL180T-L434 6039103

Expansion unit

PNP

Cable, 2-wire, 2 m WLL180T-F232 6039098

Plug M8, 3-pin WLL180T-F333 6042429

Plug M8, 4-pin WLL180T-F434 6039102

NPNCable, 2-wire, 2 m WLL180T-E232 6039100

Plug M8, 4-pin WLL180T-E434 60391041)Up to 15 expansion units can be connected.

Page 99: Sick Fibre Optic Sensors and Fibers

E

8014999/2012-05Subject to change without notice

9 9F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Wll180t

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Dimensional drawings

Infrared light • Device type: Stand-alone • type of light: Infrared light • Adjustment: Teach-in button, cable, increment button +/– manual • Max. sensing range: 0 mm to 1,000 mm, through-beam system (sensing range at response time 8 ms. Sensing range reduction with shorter

response time [see tables LL3/WLL180T].) • Connection: Plug M8, 4-pin

output signal switching device Model name part no.

PNP WLL180T-P474 6039618

NPN WLL180T-N474 6039619

Dimensional drawingsStand-alone

12.2

18.8

27.8 10 7 Ø 4.255.4

3.55

Ø 3.8

~ 180°

10.5 68.9 3.553

7.7

33.2

882 – Ø 2.3

4.3

5.7

10.4

Ø 8.

6

34.6

16.1

Ø 8.

6

37.3

1

2

4

5

5

6

1 LED emitter, installation of LL3 fibers (emitter fiber)2 Receiver, installation of LL3 fibers (receiver fiber)3 Fiber-optic locking mechanism4 Protective hood opens approx. 180°5 Connection6 Mounting bracket, included

Bus version

9,2 37,3

7,7

51,9

18,8

27,8 10 7Ø 4,255,4

3,55Ø 3,8

~ 180°

10,5 68,9 3,553

33,2

882 – Ø 2,3

4,3

10,4

Ø 8,

6

34,6

16,1

Ø 8,

6

5,7

1

2

4

5

5

6

1 LED emitter, installation of LL3 fibers (emitter fiber)2 Receiver, installation of LL3 fibers (receiver fiber)3 Fiber-optic locking mechanism4 Protective hood opens approx. 180°5 Connection6 Mounting bracket, included

Expansion unit

9,2 37,3

7,7

51,9

18,89,1527,8 10 7 Ø 4,255,4

3,55

10,5 68,9 3,553

33,2

88

2 – Ø 2,3

4,3

10,4

Ø 8,

6

34,6

16,1

17,8

Ø 8,

6

5,7

Ø 2,8

~ 180°

1

2

4

5

5

6

13

1 LED emitter, installation of LL3 fibers (emitter fiber)2 Receiver, installation of LL3 fibers (receiver fiber)4 Protective hood opens approx. 180°5 Connection6 Mounting bracket, includedâ Bus plug

Dimensions in mm

Page 100: Sick Fibre Optic Sensors and Fibers

E

8014999/2012-05Subject to change without notice

1 0 0 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Wll180t

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Adjustments/connection

Adjustments

3

7 8 9

11

10

12

–+

MODE TEACHOUT

3 Fiber-optic locking mechanism7 LED indicator orange: Lights up when output signal switching device is active8 Numeric display 2 x 4-digit; green: switching threshold, operating mode; red: actual value,

teach-in button and function parameter9 Step button > (manual switching threshold: higher/next function parameter)ß Step button < (manual switching threshold: lower/previous function parameter)à Mode/enter button (programming button)á Teach-in pushbutton

Connection type and diagramStand-alone cable, 4-wire, 2 m

L+

M

Q1

Ext. Input

brn

blu

blk

wht

Stand-alone plug M8, 4-pin

L+

M

Q1

Ext. Input

1

3

4

2

brn

blu

blk

Base/expansion unit plug M8, 3-pin plug M8, 4-pin

L+*)

M*)

Q1

Ext. Input

1

3

4

2

brn

blu

blk

*) Only base unit

Expansion unit cable, 2-wire, 2 m

L+*)

M*)

Q

Ext. Input

brn

blu

blk

wht

*) Only base unit

Page 101: Sick Fibre Optic Sensors and Fibers

E

8014999/2012-05Subject to change without notice

1 0 1F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Wll180t

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Page 102: Sick Fibre Optic Sensors and Fibers

F

8014999/2012-05Subject to change without notice

1 0 2 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Appendix

A perfect match: For optimal integration of sensors in your systems, the use of perfectly matched accessories is indispensable.

Reliable signal transmission guarantees productivity – high-quality connectivity components with long service life reduce costs. With this in mind, SICK provides suitable connection technology for every application and industry. The comprehensive range of plug connectors provides the right cabling for every application.

When it comes to mounting and adapting the sensors, SICK has the ideal solution.

sensors and accessories from siCK

Page 103: Sick Fibre Optic Sensors and Fibers

43

11

10

6,5 5

310

15 13

15

F

8014999/2012-05Subject to change without notice

1 0 3F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Appendix

Appendix

Mounting systems/connectors 104

Fibers dimensional drawings 106

Index by part no.Index by model name

138140

Page 104: Sick Fibre Optic Sensors and Fibers

F

8014999/2012-05Subject to change without notice

1 0 4 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Mounting systems/connectorsAppendix

Mounting brackets/plates

Figure Mounting system type Material Model name part no.

Mounting bracket Steel, zinc-coated BEF-WLL170 5306574

BEF-WLL170

27

79 10

4,3

5,2

243,2

89,5929,2

5,3

4,2

3,2

ø4,2

8,5

8,5

35

Adapter sleeves for fibers

Figure Description Model name part no.- Adapter sleeve for LL3 fibers, Ø 1,0 mm* BF-WLL160-10 5305479

- Adapter sleeve for LL3 fibers, Ø 1,3 mm* BF-WLL160-13 5306094

* Included with LL3.

BF-WLL160-1x

29,2

14,7

Other mounting accessories

Figure Description Model name part no.

End cap for block installation on DIN-rail mounting 1 BF-EB01-W190 5313011

Fiber-optic cutter FC 5304141

BF-EB01-W190

43

11

10

6,5 5

3

10

22

10

15 13

15

FC

Page 105: Sick Fibre Optic Sensors and Fibers

F

8014999/2012-05Subject to change without notice

1 0 5F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Mounting systems/connectors Appendix

Plug connectors and cablesFigure plug type Enclosure

ratingCable outlet Connection sheath

materiallength of

cableModel name part no.

Cable socket IP 67

Straight

Plug M8, 3-pin PVC

2 m DOL-0803-G02M 6010785

5 m DOL-0803-G05M 6022009

10 m DOL-0803-G10M 6022011

Plug M8, 4-pin PVC

2 m DOL-0804-G02M 6009870

5 m DOL-0804-G05M 6009872

10 m DOL-0804-G10M 6010754

Angled

Plug M8, 3-pin PVC

2 m DOL-0803-W02M 6008489

5 m DOL-0803-W05M 6022010

10 m DOL-0803-W10M 6022012

Plug M8, 4-pin PVC

2 m DOL-0804-W02M 6009871

5 m DOL-0804-W05M 6009873

10 m DOL-0804-W10M 6010755

DOL-0803-GxxM

M8x

1

Ø 9,

8

Ø 9

8,2 27 *L*

1/brn3/blu4/blk

DOL-0804-GxxMM

8x1

Ø 9,

8

Ø 9

8,2 27 *L*

1/brn3/blu2/wht4/blk

Alle Maße in mmDOL-0803-WxxM

22,8

*L*

Ø 9,

8

18,81/brn3/blu

4/blk

DOL-0804-WxxM22

,8*L

*

Ø 9,

8

18,81/brn3/blu

2/wht4/blk

Alle Maße in mm

Page 106: Sick Fibre Optic Sensors and Fibers

G

8014999/2012-05Subject to change without notice

1 0 6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Dimensional drawings

LL3-DB01

LL3-DB01-10 LL3-DB01-30

LL3-DB03

LL3-DB01-3

LL3-DB02

Appendix

Ø 0.26 x 16 ReceiverØ 1 Sender

55

15 200010

1) Receiver2) Sender

Ø 2.5 M6 x 0.75 1) 2) Ø 2.2 x 2

All dimensions in mm

Ø 0.26 x 16 ReceiverØ 1 Sender

55

15 300010

Ø 2.5 M6 x 0.75 1) 2) Ø 2.2 x 2

All dimensions in mm1) Receiver2) Sender

Ø 0.26 x 16 Receiver

Ø 1 Sender

10 55 1590 20001)

3)

2)

1) Flexible end tip, do not bend in this area (10 mm), bend radius R10 mm2) Sender (marked blue)3) Receiver

Ø 2.5 M4 x 0.7 M6 x 0.75 Ø 2.2 x 2

All dimensions in mm

Ø 0.26 x 16 ReceiverØ 1 Sender

55

15 1000010

Ø 2.5 M6 x 0.75 Ø 2.2 x 2

All dimensions in mm

1) 2)

1) Receiver2) Sender

Ø 0.26 x 16 ReceiverØ 1 Sender

55

15 300010

Ø 2.5 M6 x 0.75 1) 2) Ø 2.2 x 2

All dimensions in mm1) Receiver2) Sender

Ø 2.2

200020

M6 x 0.75

3

Ø 0.25 x 16 (Receiver)Ø 1 x 1 (Sender)

Ø 2.5

All dimensions in mm

Page 107: Sick Fibre Optic Sensors and Fibers

G

8014999/2012-05Subject to change without notice

1 0 7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Dimensional drawings

LL3-DB04 LL3-DB05

LL3-DB07

LL3-DB09

LL3-DB06

LL3-DB08

Appendix

823 2000

M6M4

5

Ø 0.25 x 16

Ø 1 x 1

Ø 2.

2.2

All dimensions in mm

All dimensions in mm

40 15 2000Ø 1 x 2

5.5

Ø 2.5Ø 3.5

M6 x 0.75

Ø 6 Ø 2.2 x 2

20 7510 10

5

1)

1) bendable

40 12 2000

10 105 20

3.5

Ø 0.5 x 2

Ø 1.48

Ø 2.5

M4 x 0.7

Ø 4 Ø 1 x 2

All dimensions in mm

All dimensions in mm

15 15 1000

10Ø 3.2

20 69.5 30.519

Ø 5.3

Ø 0.13 x 9Ø 0.27 x 1

2.7

Ø 0.8M3 x 0.5

Ø 4Ø 3.7Ø 2Ø 3

20

All dimensions in mm

12

17 2000Ø 0.27 x 9

Ø 0.5 x 1

2.8

1.2Ø 1.0

Ø 1.25Ø 3.2

Ø 2.

3

M3 x 0.5

20

20

60Ø 5.1Ø 5

2000

Ø 2.2 x 2

205Ø 1.5 x 2

M6 x 0.75

Ø 1 x 2

Ø 4

52

13

R5

5

90°±5°

All dimensions in mm

Page 108: Sick Fibre Optic Sensors and Fibers

G

LL3-DB10

LL3-DC04 LL3-DC05

LL3-DC07

LL3-DC03

LL3-DC06

8014999/2012-05Subject to change without notice

1 0 8 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Appendix Dimensional drawings

All dimensions in mm

15 20007 202.7

Ø 1 x 2

Ø 3 Ø 3.2 Ø 1.3 x 2

30 4000

Ø 1.5 x 1

Ø 2.2 x 26.51920

Ø 3.2

Ø 3.2 x 2

25

8

157.5

7.5

Ø 3.2 x 37.3

All dimensions in mm

All dimensions in mm

17

29 200018 6.5 20

Ø 1.3 x 2Ø 310

M3 x 23.8

2.5

All dimensions in mm

29 3000

18 6.52.5

Ø 0.25 x 9

20

3.8

10

Ø 3.2

M3 x 220 Ø 1.3 x 2

All dimensions in mm

29 300018 6.5

323

.5

4.5

M3 x 2 Ø 2.2 x 2

Ø 1 x 1 Ø 0.27 x 16

1)

1) 2)

2)

1) Sender2) Receiver

M3 x 2Ø 1 x 2

7

424 16

39.5

21 2000

20

Ø 3

All dimensions in mm

Page 109: Sick Fibre Optic Sensors and Fibers

G

LL3-DC08 LL3-DC09

LL3-DC39

LL3-DC57

LL3-DC38

LL3-DC47

8014999/2012-05Subject to change without notice

1 0 9F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

AppendixDimensional drawings

10007

0.52.5

1.51.2 20 Ø 1 x 2

1.3

1.7

5 7.2

M2 Ø 3

Ø 0.5

Ø 0.05 x 151

2 0.5

Ø 1.63

1.5 All dimensions in mm

18

5.5

12

2000

[30]64 7 3.5

2 – Ø 3.2 Ø 1 x 2

All dimensions in mm

200025.5

15

Ø 1

x 2

7.2

2 x Ø 2.1

10.51

1

2.52 x Ø 0.5

44

All dimensions in mm

6

2000142.5

20

18

13

Ø 3 x 2

Ø 3 Ø 1 x 2Ø 0.5 x 1

All dimensions in mm

Ø 3.2 x 2 Ø 1 x 2

4.3

12

5.5 3.5

30

718 2000

All dimensions in mm

200025.5

15

Ø 1

2 x Ø 3.6

Ø 0.5

10.5

62.

5

4

4

2.5

2 x Ø 2.1

All dimensions in mm

Page 110: Sick Fibre Optic Sensors and Fibers

G

LL3-DE01

LL3-DE03 LL3-DE04

LL3-DF04

LL3-DE02

LL3-DF02-S01

8014999/2012-05Subject to change without notice

1 1 0 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Appendix Dimensional drawings

10007

Ø 2.2

3.5

1.2

20

Ø 1 x 2

Ø 3

2

0.5

5

Ø 1.

5

1.05

Ø 0.5 Ø 0.04 x 151multicore fiber

10

42.

5

2.2

All dimensions in mmØ 0.5 Ø 0.0375 x 151

1000

20

7

5

10

2.3

10

2 Ø 2.2

Ø 1 x 2Ø 3

All dimensions in mm

3.5

2.5

2.2

4

0.5

1.05

10.

6

615±0.5 2

28 2000+100

2 x

Ø 2.

2Ø 5

Ø 6±

3

All dimensions in mm

2000

20

14

1.05

7

7

3.5

Ø 3.2 Ø 1.3 x 2

Ø 1

All dimensions in mm

3.51.2

3.5

6.5

2.2

Ø 2.

4

1

200011

Ø 3.2

7 2.9

Ø 3.2 Ø 1.3 x 2

Ø 1

20

7

14

3.5

All dimensions in mm

1.05

Ø 2.

41

6.5

3.5

3.5

2.2

1.6

0.9

Ø 0.075 x 151

13 104

13.5

25

2085

2 x Ø 3.2

Ø 3Ø 1 x 2

2014 2000

146

All dimensions in mm

Page 111: Sick Fibre Optic Sensors and Fibers

G

LL3-DF05 LL3-DF07

LL3-DH01-03

LL3-DH03

LL3-DH01

LL3-DH02

8014999/2012-05Subject to change without notice

1 1 1F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

AppendixDimensional drawings

13 104

13.5

25

2085

2 x Ø 3.2

Ø 3Ø 1 x 2

2014 2000

146

All dimensions in mm

Ø 1.5 x 2

Ø 1.5

Ø 4.9 M6 x 0.75 Ø 2.2 x 2

3 1519 2000

All dimensions in mm

Ø 2.2

5 15 2000510

Ø 1 x 2 Ø 2.5 M6 x 0.75

All dimensions in mm

8.75

6.5

17.1

3 2.5

3 2.5

22.2

5.2

28.3

2000

17

Ø 1.3 x 2

All dimensions in mm

20.3

9.4

7.8

5.2

0.9

Ø 1.5 x 2

Ø 1.5

Ø 4.9 M6 x 0.75 Ø 2.2 x 2

3 1519 3000

All dimensions in mm

3

Ø 3

M6 X 0.75

Ø 4

Ø 2.2

Ø 5Ø 3.8

Ø 10 Ø 5

17

30 60 ± 5 16.7 18.3

22 2000

All dimensions in mm

Page 112: Sick Fibre Optic Sensors and Fibers

LL3-DH04

LL3-DH06 LL3-DH07

LL3-DH09

LL3-DH05

LL3-DH08

G

8014999/2012-05Subject to change without notice

1 1 2 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Appendix Dimensional drawings

M6 x 0.75

Ø 1.8

Ø 2.8Ø 4

Ø 5Ø 5Ø 3Ø 3.8

Ø 10

17

20002260

16.7 18.360 ± 530

All dimensions in mm

Ø 2.1

Ø 2.9

30

16.7 18.3

Ø 3

Ø 10

Ø 50 μm x 380Sender / Receiver

Ø 4

M4 x 0.7

2790 10003560

All dimensions in mm

Ø 5

Ø 5Ø 3.1

Ø 50 μm x 380 5520

2 x M3 x 0.5 Ø 2.2 x 2

7

8

20

195

2000

Ø 1.5 x 1

All dimensions in mm

6.510.75

2.7

4

Ø 4.

619

8

Ø 5

20

16.7 18.3

7

5

2000

Ø 1.2

Ø 4

All dimensions in mm

2 x M3 x 0.5 Ø 2.94

10.756.5

16.7

Ø 4.

6

M4 x 0.7

Sender / ReceiverØ 50 μm x 440

20

5

Ø 10Ø 3.1

3.5

Ø 2.9

27

Ø 3 Ø 5

1000

356030

Ø 4

Ø 5

All dimensions in mm

5 16.7 18.3

Ø 8.5

M6 x 0.75

5.5 5Ø 1.5 x 2

Ø 5Ø 2.2 x 2

16 2000

All dimensions in mm

Page 113: Sick Fibre Optic Sensors and Fibers

LL3-DH10 LL3-DH11

LL3-DJ02

LL3-DK06

LL3-DJ01

LL3-DK04

G

8014999/2012-05Subject to change without notice

1 1 3F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

AppendixDimensional drawings

Ø 5

39.7

Ø 3.8

Ø 2.9

2 x M3

Ø 4.

332

x Ø

2.2

21

5

300033.2

21.7 6.5 35

18.3

Ø 4.3

All dimensions in mm

2

4.5

Ø 1

M3 x 0.5

Ø 3.5

12

6

18

Ø 2.3 Ø 1.3Ø 4.5

1000

300Ø 0.25 x 9

Ø 0.5 x 1

700

Ø 4.5

All dimensions in mm

1)

2)

1) Receiver2) Sender

1)2)

1.2

Ø 1.3

200017

Ø 3Ø 1 x 2

All dimensions in mm

Ø 5

39.7

Ø 3.8

Ø 2.9

2 x M3

5

300034.5

23 6.5 35

18.3

All dimensions in mm

21

2

4.5

2 x

Ø 2.

2

5.5

Ø 0.25 x 9

M6 x 0.75

15

35

15

Ø 3.5

Ø 4.5

19 1000

100

Ø 4.3Ø 6

All dimensions in mm

Ø 2.2

200018

M6 x 0.75

3

Ø 4

Ø 1 x 2

All dimensions in mm

Page 114: Sick Fibre Optic Sensors and Fibers

LL3-DK21

LL3-DK43 LL3-DK04Z

LL3-DK66

LL3-DK33

LL3-DK63Z

G

8014999/2012-05Subject to change without notice

1 1 4 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Appendix Dimensional drawings

M3 x 0.5

500100

15

Ø 2.1Ø 1.6Ø 2.2

15

Ø 0.13 x 9 Receiver

Ø 0.25 Sender

All dimensions in mm

Ø 2.2

Ø 2

.7

Ø 5

15 20004.8 65

Ø 2.7

2.5

1.5

2 All dimensions in mm

M4 x 0.7

15

Ø 1.3

2000

Ø 2.

5

653

Ø 1 x 2

All dimensions in mm

Ø 1

200015

Ø 4

Ø 0.5 x 2Ø 1.5

20

All dimensions in mm

Ø 1.3

200017

Ø 3

Ø 1 x 2

All dimensions in mm

M4 x 0.7

12

Ø 1.3

20003

Ø 1 x 2

All dimensions in mm

Page 115: Sick Fibre Optic Sensors and Fibers

LL3-DK67 LL3-DM01

LL3-DM03

LL3-DR01

LL3-DM02

LL3-DP01

G

8014999/2012-05Subject to change without notice

1 1 5F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

AppendixDimensional drawings

Ø 2.2

200012

M6 x 0.75Ø 1 x 2

All dimensions in mm

M4 x 0.7

Ø 0.5 SenderØ 0.25 x 9 Receiver

2000123

Ø 1.3 x 2Ø 8.5

All dimensions in mm

Ø 4.3

Ø 5.3

Ø 3.7Ø 1.5

3 15 1000

20 10020

Ø 0.5

Ø 2Ø 0.13 x 4

3.7

3518.3

All dimensions in mm

Ø 1.0 x 2 Ø 1.3 x 2M4

2000123

All dimensions in mm

M4 x 0.7

Ø 0.5 x 1

3

Ø 1.5

90 5 12 2000

Ø 1 x 2Ø 2.5

1)

1) Flexible end tip, do not bend in this area (10 mm), bend radius R10 mm

All dimensions in mm

5.2 12 2000

Ø 2.2 x 2

Ø 0.27 x 16

M6 x 0.75

All dimensions in mm

Page 116: Sick Fibre Optic Sensors and Fibers

LL3-DR02

LL3-DR04 LL3-DR05

LL3-DR07

LL3-DR03

LL3-DR06

G

8014999/2012-05Subject to change without notice

1 1 6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Appendix Dimensional drawings

M3 x 0.5 Ø 1 x 2

100013Ø 0.25 x 2

All dimensions in mm

10 2000

Ø 1.0 x 2Ø 3

Ø 0.25 x 4 SenderØ 0.25 x 4 Receiver All dimensions in mm

M2, 6 x 0.45

Ø 0.25 x 4

M4 x 0.7

2000123 3

Ø 1 x 2

All dimensions in mm

Ø 0.25 x 2

Ø 1.5

Ø 1.5 Ø 1 x 2Ø 3

90015

1525

100

Ø 1.2 Ø 2.2 x 2

All dimensions in mm

Ø 0.82 Ø 3

500

Ø 1.2 x 2

Ø 0.25

5 15 15 75 25

Ø 3Ø 2.2 x 2

All dimensions in mm

1000100

25

Ø 1.2Ø 3Ø 0.8

151580

Ø 0.25 x 2

All dimensions in mm

Page 117: Sick Fibre Optic Sensors and Fibers

LL3-DR08 LL3-DR09

LL3-DR11

LL3-DS06

LL3-DR10

LL3-DR12

G

8014999/2012-05Subject to change without notice

1 1 7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

AppendixDimensional drawings

M3 x 0.5

2.7

12 200020

Ø 3.2 Ø 1 x 2

Ø 0.25 x 2

All dimensions in mm

20001240

M4 x 0.7Ø 2.5Ø 1.48 Ø 1 x 2

10 510

(Ø 0.05 x 151) x 2

3.5

All dimensions in mm

1)

1) bendable

Ø 1 x 2

20

Ø 2 Ø 3 Ø 3.2

1

1515 2000

Ø 0.05 x 151

Ø 0.5

All dimensions in mm

9.5

15 2000

20

10.2

12.2

t 1.26

2 x M3 x 0.5

Ø 2.2 x 25.2

14

Ø 1

Ø 0.08 x 151

All dimensions in mm

4

3.3

3.34

7

4.6

2000

7

15

Ø 1.25Ø 3 (SUS)

Ø 1

Ø 0.27 x 9

Ø 0.5 x 1(Ø 0.05 x 151) x 1

2.7

All dimensions in mm

2)

1)

1) Receiver2) Sender

M3 x 0.5 Ø 1.0 x 2Ø 0.5 x 2

Ø 5.5Ø 2.5

12 2000

All dimensions in mm

Page 118: Sick Fibre Optic Sensors and Fibers

LL3-DT01

LL3-DT02 LL3-DT03

LL3-DT05

LL3-DT01-05

LL3-DT04

G

8014999/2012-05Subject to change without notice

1 1 8 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Appendix Dimensional drawings

All dimensions in mm

Ø 0.25 x 9 ReceiverØ 0.5 Sender

1)

2) Ø 1.3 x 2M3 x 0.5

13 518 2000

1) Sender2) Receiver All dimensions in mm

Ø 0.25 x 9 ReceiverØ 0.5 Sender

1)

2) Ø 1.3 x 2M3 x 0.5

13 518 2000

1) Sender2) Receiver

Ø 0.13 x 9Ø 0.25

Ø 3

10 515 500

Ø 1.0 x 2M3 x 0.5Ø 0.8 Ø 2.2 x 2

1)

1) End tip cannot be bent

All dimensions in mm

Ø 0.25 x 1Ø 3 Ø 1.0 x 2Ø 0.82

M3 x 0.5

1015 52.4

All dimensions in mm

1)

1) End tip cannot be bent

500

Ø 0.5 x 2

Ø 2.5

Ø 2.5

10 2000

Ø 1.0 x 2

All dimensions in mm

M4 x 0.7

12

Ø 1

2000

Ø 1.

5

Ø 2.

5

283

Ø 0.5 x 2

5

All dimensions in mm

Page 119: Sick Fibre Optic Sensors and Fibers

LL3-DV01 LL3-DV02

LL3-DV05

LL3-DV07

LL3-DV03

LL3-DV06

G

8014999/2012-05Subject to change without notice

1 1 9F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

AppendixDimensional drawings

Ø 5Ø 2.7

200015204.88

1.5

2

Ø 2.2 x 2

All dimensions in mm

2.5

Ø 2.7

2

5 20 2000

M6 x 0.75

Ø 115

Ø 2.2 x 2

All dimensions in mm

Ø 0.5 x 2 Ø 1

15101.5

2

20002.8

All dimensions in mm

Ø 1.5 Ø 3

200012

52.

4

6.8

14.4

4.4

10

All dimensions in mm

M6

200012

5

2.4

6.8

14.4

4.4

10

All dimensions in mm

M6

200012

5

2.4

6.8

14.4

4.4

10

All dimensions in mm

M6

Page 120: Sick Fibre Optic Sensors and Fibers

LL3-DW01

LL3-DW02 LL3-DY01

LL3-DZ02

LL3-DW01-2

LL3-DZ01

G

8014999/2012-05Subject to change without notice

1 2 0 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Appendix Dimensional drawings

Ø 5

Ø 10

Ø 4

Ø 5 M6 P = 0.45

15

256020

22

123

1000

Ø 4

Ø 1.5Ø 2

All dimensions in mm

1) 2)

1) Receiver2) Sender

Ø 3.2

Ø 0.27 x 16

Ø 1 x 1

2 x Ø 3.3

15

7

28 2000

All dimensions in mm

1)

2)

1) Sender2) Receiver

3.6

20

30005000

1010

30 Ø 3.1

Ø 1 x 2

Ø 4.2

6.217

17.7 11

15.5

5.712

11

All dimensions in mm

protectivetube

SUS

PVC

162000

2100

Ø 2.2 x 2Ø 2.2Ø 6

All dimensions in mm

20 20005

2010.9

13

1

3 x M3 x 0.5

Ø 3.2 x 2

10

All dimensions in mm

Array: Ø 0.265 x 32

15

2.5

2.5

Ø 5

Ø 10

Ø 4

Ø 5 M6 P = 0.45

15

256020

22

123

1000

Ø 4

Ø 1.5Ø 2

All dimensions in mm

1) 2)

1) Receiver2) Sender

Page 121: Sick Fibre Optic Sensors and Fibers

LL3-DZ03 LL3-RB01

LL3-RB02 LL3-RG01

G

8014999/2012-05Subject to change without notice

1 2 1F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

AppendixDimensional drawings

20 2000

5

20 13

153 x M3 x 0.5

Ø 0.27 x 32

Ø 3.2 x 2

10

10.851

All dimensions in mm

Array: Ø 0.265 x 32

2.5

2.5 8

2000253

20

9.5

12.2

10.2

614

5.2

Ø 1 x 2

t 1.2Ø 2.2

All dimensions in mm

4

43.3 3.

3

2-M3 x 0.5

200021

2 x M3 x 0.520

9.5

12.2

10.26

14

5.2

Ø 1 x 2

t 1.2 Ø 2.2

All dimensions in mm

4

43.3 3.

3

21.5

8

21.5

2 x M1.4 x 0.3

4

1.55

9

3

Ø 3.2

20

Ø 1 x 2

2000

7.5

11 9

2 x M1.4 x 0.3

15.84

42

1.9

1 2

11.2

Ø 0.5 x 1

2.2

0.7 1.45

14.75 1.95

All dimensions in mm

0.7

2

Page 122: Sick Fibre Optic Sensors and Fibers

LL3-TB01-10

LL3-TB02LL3-TB01-30

LL3-TB01LL3-RR01

G

8014999/2012-05Subject to change without notice

1 2 2 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Appendix Dimensional drawings

Ø 1.5 M2, 6 x 0.45 M4 Ø 2.2

3 12 3000037

All dimensions in mm

Ø 1.5 M2, 6 x 0.45 M4 Ø 2.2

3 12 1000037

All dimensions in mm

Ø 1M4 x 0.7

M2, 6 x 0.45

1233

2.2

2000

All dimensions in mm

200015

1 20

5.29.5

4.6

9.5

4.6

5

Ø 2.2 x 2

Ø 3.2

5.2

15

2 x M3 x 0.5

10.2

12.2

147

2

6

1

2000

Ø 1

Ø 0.08 x 151

All dimensions in mm

43.3 3.

3

4Ø 1.5 M2, 6 x 0.45 M4 Ø 2.2

3 12 200037

All dimensions in mm

Page 123: Sick Fibre Optic Sensors and Fibers

LL3-DB03 LL3-TB05

LL3-TB07

LL3-TE01

LL3-TB06

LL3-TB08

G

8014999/2012-05Subject to change without notice

1 2 3F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

AppendixDimensional drawings

Ø 1 Ø 1.5 Ø 2.5 M4 Ø 2.2

15 200059073

All dimensions in mm

1)

1) Flexible end tip, do not bend in this area (10 mm), bend radius R10 mm

Ø 1.2M4 x 0.7M2.6 x 0.45

Ø 2.2Ø 2.7

553

3.2

Ø 1 x 1

90°±5°

Ø 3.2

11

202000

20

All dimensions in mm

23 178

10000

M14 x 1Ø 4.5

Ø 7Ø 10Ø 2.2

All dimensions in mm

M3 x 0.5Ø 2Ø 0.88Ø 0.5 x 1

2.7200040

1010 5

10

Ø 1

All dimensions in mm

1)

1) bendable

2000

Ø 1 x 1

8

Ø 2.2Ø 2.5

Ø 3

20

All dimensions in mm

1000

20

Ø 1

102.

5

73.51.22

5

1.05

Ø 1.

5

0.5

Ø 2.2

Ø 0.04 x 151

Ø 0.5

Ø 2

All dimensions in mm

Page 124: Sick Fibre Optic Sensors and Fibers

LL3-TE05LL3-TE04

LL3-TG01LL3-TF01

LL3-TE03LL3-TE02

G

8014999/2012-05Subject to change without notice

1 2 4 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Appendix Dimensional drawings

6

Ø 3.1

1000

2000

10.3

5.5

7.2

23

17

20

12

9

20

Ø 4 Ø 1 x 2

All dimensions in mm

Ø 0.25 x 7 1.75 7.5

2.4

3.9 11 2000

2 x Ø 2.2Ø 1.258.

5

3

All dimensions in mmØ 0.08 x 151

2000

20

Ø 1.3

7

2.4

143.

5

2.9

113.5 3.51

1.05

Ø 3.2

Ø 1

Ø 2

All dimensions in mm

0.6

1

20 20008

Ø 2.2

20

Ø 4Ø 3.5Ø 3.7Ø 2.2

All dimensions in mm

Ø 0.04 x 151

1000

20

Ø 1

7

5

Ø 1.

5

10.

6

10

2.5

2.3

103.520.5

1.05

Ø 2.2

Ø 0.5

Ø 2

All dimensions in mm

2000

20

Ø 1.3

2.4

143.

5

7

1.23.5

3.51

Ø 3.2

Ø 2

1.05

Ø 1

Ø 0.08 x 151

All dimensions in mm

Page 125: Sick Fibre Optic Sensors and Fibers

LL3-TG02 LL3-TG03

LL3-TG05

LL3-TH02

LL3-TG04

LL3-TH01

G

8014999/2012-05Subject to change without notice

1 2 5F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

AppendixDimensional drawings

Ø 4 Ø 2.220

25

1233.7

Ø 2.5

2000

Ø 1

Ø 0.08 x 151

All dimensions in mm

1.5

1.3

21.7

200020

20180.5

Ø 1

Ø 0.5 x 1

Ø 2

All dimensions in mm

Ø 1.0 M2, 6 x 0.45 M4 Ø 2.2

73

3 12 2000

All dimensions in mm

200025

123

3.7

Ø 4 Ø 2.2

20

All dimensions in mm

Ø 2.5 Ø 1

Ø 0.05 x 151

Ø 0.5

1515201

Ø 1 Ø 2

2000

All dimensions in mm

2000

Ø 2.2

17

15

3

1

Ø 3 M4

7

Ø 1.5

All dimensions in mm

Page 126: Sick Fibre Optic Sensors and Fibers

G

LL3-TH08

LL3-TH10LL3-TH09

LL3-TH07LL3-TH06

8014999/2012-05Subject to change without notice

1 2 6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Appendix Dimensional drawings

60 27 2000

5 17

Ø 1.2

Ø 2.1

Ø 3M4 x 0.7

Ø 4 Ø 2.9Ø 5 Ø 2.2

16.718.3

All dimensions in mm

Ø 5Ø 4

3 200027

17 16.7 18.3

Ø 2.2

Ø 1.2

M4 x 0.7M2.6 x 0.45Ø 2.9

All dimensions in mm

3 20 1000

3518.3

Ø 2.2Ø 4.33

Ø 1.6

Ø 2.5M2.6 x 0.45

M4 x 0.7

3.5

Ø 0.8

All dimensions in mm

100010 15

10001525

Ø 1Ø 2.5

Ø 2.5 Ø 1

2.2

2.2

Ø 1

All dimensions in mm

45°

0.51

1

0.51

135°1

Ø 1

1)

1)

1) angle of beam

11.

751.

5

8 1210 15

2000

Ø 2.9 Ø 2.2Ø 1

Ø 4

All dimensions in mm

Page 127: Sick Fibre Optic Sensors and Fibers

G

LL3-TH11 LL3-TH12

LL3-TH13

8014999/2012-05Subject to change without notice

1 2 7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

AppendixDimensional drawings

3 20 1000

16.718.3

Ø 2.2Ø 5

12

Ø 2.9Ø 4

M4 x 0.7

3.5

Ø 1.1

M2.6 x 0.45

All dimensions in mm

All dimensions in mm

6

23 300+25

12

32.5

M2.6 x 0.45

M4 x 0.7

Ø 4

9.3

5.4

Ø 3.5Ø 2.7

285+30 25.8 200017 20

Ø 2.2

Ø 4M4 x 0.7

All dimensions in mm

6

23 200+25

12

32.5

M2.6 x 0.45

M4 x 0.7

Ø 4

9.3

5.4

Ø 3.5Ø 2.7

185+30 25.8 200017 20

Ø 2.2

Ø 4M4 x 0.7

Page 128: Sick Fibre Optic Sensors and Fibers

LL3-TH16

LL3-TJ01LL3-TH17

LL3-TH15LL3-TH14

G

8014999/2012-05Subject to change without notice

1 2 8 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Appendix Dimensional drawings

All dimensions in mm

3.53 13 2000

Ø 2.2Ø 3

M4 x 0.7

Ø 1.5 x 1

12

24 800+25

Ø 3.8 Ø 4 9.3

Ø 3.5

5.4

Ø 2.7

24 25.8 2000785+55

17 20

Ø 2.2

Ø 4M4 x 0.7

128

2.2

6

All dimensions in mm

All dimensions in mm

12320 1000

4.7 3518.3

Ø 4

Ø 3.1

Ø 4 Ø 2.2

Ø 4.33

3.5

M2.6 x 0.45

M4 x 0.7

Ø 0.27 x 16

All dimensions in mm

623 500+25

12

32.5

M2.6 x 0.45

M4 x 0.7

Ø 4

9.3

5.4

Ø 3.5Ø 2.7

485+30 25.8 200017 20

Ø 2.2

Ø 4M4 x 0.7

24 500+25

Ø 3.8 Ø 4 9.3

Ø 3.5

5.4

Ø 2.7

24 25.8 2000485+30

17 20

Ø 2.2

Ø 4M4 x 0.7

128

2.2

6

All dimensions in mm

Page 129: Sick Fibre Optic Sensors and Fibers

LL3-TK05

LL3-TK77

LL3-TM02

LL3-TK16

LL3-TM01

LL3-TM03

G

8014999/2012-05Subject to change without notice

1 2 9F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

AppendixDimensional drawings

14

Ø 3Ø 1 Ø 2.2

2000

All dimensions in mm

M4 x 0.7M2, 6 x 0.45

12

Ø 2.2

200033

Ø 1

All dimensions in mm

2.4

M3 x 0.5

Ø 2

Ø 0.5

5 10 2000

Ø 1.0

All dimensions in mm

4

3.6 Ø 2.2

22 2000

3.5

32

All dimensions in mm

Ø 1.0

2.5

M3

10 2000

Ø 1.3

All dimensions in mm

Ø 0.5 Ø 1.5

10 2000

Ø 1.0

All dimensions in mm

Page 130: Sick Fibre Optic Sensors and Fibers

LL3-TR01LL3-TP01

LL3-TR02LL3-TR01-05

LL3-TR03-2LL3-TR03

G

8014999/2012-05Subject to change without notice

1 3 0 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Appendix Dimensional drawings

Ø 0.25 x 4 Ø 1.5 Ø 1.0

10 1000

All dimensions in mm

2.5

Ø 1.0Ø 0.25 x 4

10 2000

M3 x 0.5

All dimensions in mm

Ø 0.25 x 4 Ø 1.5 Ø 1.0

10 20000

All dimensions in mm

All dimensions in mm

Ø 0.25

Ø 0.13 x 1

5 10 50020

Ø 3 Ø 3.2 Ø 1.2Ø 4.33 Ø 2.2

3518.3

3

Ø 0.26 x 16

1237 2000

Ø 2.2M4M2. 6 x 0.45

All dimensions in mm

3

Ø 0.26 x 16

1237 2000

Ø 2.2M4M2, 6 x 0.45

All dimensions in mm

Page 131: Sick Fibre Optic Sensors and Fibers

LL3-TR04 LL3-TR05

LL3-TR06 LL3-TR08

LL3-TR09 LL3-TR10

G

8014999/2012-05Subject to change without notice

1 3 1F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

AppendixDimensional drawings

All dimensions in mm

6 5003

2035

18.3

Ø 2.2

Ø 4.33Ø 1.4Ø 0.7

Ø 1

Ø 0.27 x 1

11 1

2000

Ø 1.252 x Ø 2.2

7.51.75

23.

53

8 2.5

Ø 0.25 x 7

All dimensions in mm

14.6

Ø 1 Ø 0.08 x 151

3.2 R2

69

20Ø 3.2 Ø 2.2

2000

74.

412

.9

8.5

M4 x 0.7

All dimensions in mm

All dimensions in mm

311

12000

Ø 1.25

2 x Ø 2.27.51.75

Ø 0.25 x 7

82.

5

23.

5

13.9

Ø 1 Ø 0.08 x 151

3.2 R2

69

20Ø 3.2 Ø 2.2

2000

74.

412

.9

8.5

M4 x 0.7

All dimensions in mm

8 20002

Ø 2

Ø 1 Ø 0.08 x 151

Ø 3 Ø 2.2

All dimensions in mm

Page 132: Sick Fibre Optic Sensors and Fibers

LL3-TS07

LL3-TS10LL3-TS08

LL3-TR12LL3-TR11

LL3-TR13

G

8014999/2012-05Subject to change without notice

1 3 2 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Appendix Dimensional drawings

1.5

1.8

1.4

1

Ø 2.2Ø 3

30 2000

Ø 1.0

All dimensions in mm

Ø 1.5

Ø 3

15 2000

Ø 2.2

All dimensions in mm

1

5.2

16 x

0.2

6

Ø 2.2

20

10

10

55

3

6.1

2000

M3

All dimensions in mm

All dimensions in mm

12 2000

11 2032.

58

Ø 1

Ø 0.08 x 1513.

52

1.757.52 x Ø 2.2

Ø 2.5

Ø 1.3

3

8.5

2.2

3.9

12 200020

Ø 1.3Ø 2.5

2 x Ø 2.2

117.51.75

Ø 1

Ø 0.08 x 151

All dimensions in mm

All dimensions in mm

5.5

12 2000

11 203

2.5

8

Ø 1

Ø 0.08 x 151

3.5

2

1.757.52 x Ø 2.2

Ø 2.5

Ø 1.3

Page 133: Sick Fibre Optic Sensors and Fibers

LL3-TS12

LL3-TS22

LL3-TS22V

LL3-TS14

LL3-TS22M

LL3-TS40

G

8014999/2012-05Subject to change without notice

1 3 3F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

AppendixDimensional drawings

1.80.4

Ø 2.2

20003010

3.23.6

3.2

11Ø 4

17.6

Ø 0.75

31.3

All dimensions in mm

Ø 1

200030

3.6

Ø 4

1.3

2.8

3

All dimensions in mm

1.3

32.8

Ø 4

3.6 30 2000

Ø 2.

2

All dimensions in mm

Ø 2.2

200025

10 10 55

4

19 10.5

1.1 M3 x 0.5

All dimensions in mm

1.3

32.8

Ø 43.

6 30 2000

Ø 1

All dimensions in mm

1314.5

20

69.3 200015

18.5

Ø 2.

2

7.65

3

12.3 43 3

22.340

5.1

3

2 x 3.2 x 6.22 x 6 x 9

All dimensions in mm

Page 134: Sick Fibre Optic Sensors and Fibers

G

LL3-TV04

LL3-TV06LL3-TV05

LL3-TV01LL3-TT01

LL3-TV02

8014999/2012-05Subject to change without notice

1 3 4 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Appendix Dimensional drawings

2000

Ø 4.

4

14.4 4.

4

10.5

3.5

7

All dimensions in mm

M4

1.751.5

Ø 1 Ø 1M3

2.5 1510 2000Ø 0.5

All dimensions in mm

Ø 0.25 Ø 0.5 Ø 3 Ø 1

5 15 2000

All dimensions in mm

2.2

1.5

1

20001510

Ø 2.5Ø 0.5

Ø 1 Ø 1

All dimensions in mm

Ø 3Ø 2 Ø 2.2

1520 2000

1.5

1

Ø 1.0

2.8

All dimensions in mm

2000

Ø 4.

4

14.4 4.

4

10.5

3.5

7

All dimensions in mm

M4

Page 135: Sick Fibre Optic Sensors and Fibers

G

LL3-TV07

LL3-TW01

LL3-TX01

LL3-TV08

LL3-TW01-2

LL3-TY01

8014999/2012-05Subject to change without notice

1 3 5F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

AppendixDimensional drawings

M2.6 M4

Ø 1.5 x 1

Ø 15 Ø 5 Ø 4 Ø 5

10 153 15 10

28 1000

All dimensions in mm

M12 x 1.75

26.5255.5

20000

Ø 2.

2

Ø 10

.6

Ø 10

All dimensions in mm

All dimensions in mm

15 15 2000

20

Ø 2.5Ø 2 Ø 1Ø 1

Ø 0.5

Ø 0.05 x 151

1

Ø 1.5

1006

Ø 6

Ø 5

202000

Ø 2.2

All dimensions in mm

2000Ø

4.4

14.4 4.

4

10.5

3.57

All dimensions in mm

M4

M2.6 M4

Ø 1.5 x 1

Ø 15 Ø 5 Ø 4 Ø 5

10 153 15 10

28 1000

All dimensions in mm

Page 136: Sick Fibre Optic Sensors and Fibers

LL3-TY05

LL3-TZ06LL3-TZ05

LL3-TY03LL3-TY02

LL3-TY04

G

8014999/2012-05Subject to change without notice

1 3 6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Appendix Dimensional drawings

All dimensions in mm

2000155Ø 3.2

Ø 2.22.5

10

8 2.5

3 x M3 x 0.5

15.

25

Array Ø 0.27 x 16

15

10

10

15.25

Ø 3.2200015

15

6.58Ø 2.2

2.5

10 2.53 x M3 x 0.5

5

All dimensions in mm

Array Ø 0.27 x 16

15 2000

5.8

7.5

7.3

Ø 2.2

42 x Ø 3.2

313

17

6

All dimensions in mm

All dimensions in mm

Ø 5

Ø 6

Ø 5 Ø 2.2 Ø 1.5

100200020

20001500 500

25

Ø 5.5 Ø 4 Ø 2.2

All dimensions in mm

Ø 6 Ø 5

35 max.

3000+100

100+

50

Ø 3R7.5

1 20

All dimensions in mm

Page 137: Sick Fibre Optic Sensors and Fibers

LL3-TZ07

LL3-TZ09

LL3-TZ08

LL3-TZ10

G

8014999/2012-05Subject to change without notice

1 3 7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

AppendixDimensional drawings

n 1,

3

5,2

44,2

2,2

11

8

427

194

9,5

(13,

5) 2-R 4

1

2

3

3,2

3219

n 1,

3

7,3

5,2

5

(20)

465

16

45122-R 4

1

2

3

n 1,

3

5,2

44,2

2,2

11

8

427

194

9,5

(13,

5) 2-R 4

1

2

3

3,2

3219

n 1,

3

7,3

5,2

5

(20)

465

16

45122-R 4

1

2

3

Page 138: Sick Fibre Optic Sensors and Fibers

H

8014999/2012-05Subject to change without notice

1 3 8 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Index by part no.

part no. Model name page

5308

5308048 LL3-TB02 21

5308049 LL3-TS07 27

5308050 LL3-TB01 21

5308051 LL3-TB01-10 21

5308052 LL3-TR01 22/44/76

5308053 LL3-TR02 22/44/76

5308054 LL3-TR03 26/44/76

5308055 LL3-TR03-2 26/45/76

5308056 LL3-TB03 51

5308057 LL3-TT01 51

5308058 LL3-TV01 31/51

5308059 LL3-TV02 32/52

5308060 LL3-TV04 32/52

5308061 LL3-TS08 31/51

5308062 LL3-TS12 31/51

5308063 LL3-TS10 55

5308064 LL3-TH01 21/61

5308065 LL3-TH02 21/61

5308066 LL3-TY01 65

5308067 LL3-TY02 32/65

5308068 LL3-TM01 22

5308069 LL3-TM02 22

5308070 LL3-TM03 26

5308071 LL3-DM01 18

5308072 LL3-DT03 25

5308073 LL3-DS06 19

5308074 LL3-DB01 16

5308075 LL3-DB01-10 17

5308076 LL3-DT01 19

5308077 LL3-DM02 18

5308078 LL3-DR01 18/42/75

5308079 LL3-DR02 18/42/75

5308080 LL3-DR03 25/42/75

5308081 LL3-DR04 25/42/75

5308082 LL3-DR06 19/42/75

5308083 LL3-DB02 48

5308084 LL3-DM03 49

5308085 LL3-DT02 42/50/75

5308086 LL3-DT04 43/50/75

5308087 LL3-DR05 25/75

5308088 LL3-DV01 29/50

5308089 LL3-DV02 29/50

5308090 LL3-DV03 29/50

part no. Model name page

5308091 LL3-DH01 17/58

5308092 LL3-DH02 17/59

5308093 LL3-DY01 64

5309

5309087 LL3-DT01-05 19

5313

5313019 LL3-DK06 18

5313020 LL3-DK04 24

5313021 LL3-DB03 17

5313023 LL3-DK21 18

5313024 LL3-DK66 18/41

5313025 LL3-DK67 18/42

5313026 LL3-DK4Z 25/41

5313027 LL3-DK63Z 41/49

5313028 LL3-DT05 50

5313030 LL3-DK43 49

5313031 LL3-DK33 28/49

5313034 LL3-TK05 26/44

5313035 LL3-TK77 22/44

5313038 LL3-TK16 30/51

5313039 LL3-TS14 55

5315

5315233 LL3-TW01 23/62/68

5315234 LL3-DW01 20/60/67

5315499 LL3-TB01-30 21

5321

5321260 LL3-DH01-03 17/58

5321306 LL3-TW01-2 23/62/68

5321924 LL3-DF02-S01 66

5322

5322198 LL3-TR01-05 22/44/76

5322472 LL3-DC38 35/71

5322513 LL3-DC39 35/71

5322546 LL3-TV05 22/32

5322547 LL3-TV06 22/32/62

5322548 LL3-TV07 22/32/46

5322549 LL3-DV05 19/29

5322550 LL3-DV06 19/29/60

5322551 LL3-DV07 19/29/43

5322552 LL3-DB01-3 16

5323

5323971 LL3-TS40 55

5324

5324173 LL3-TX01 23

part no. Model name page

5324242 LL3-TF01 68

5324268 LL3-DC47 35/41

5324269 LL3-DC57 35/41

5324497 LL3-DE02 36/41

5324499 LL3-TG04 73

5324662 LL3-DB01-30 17

5324787 LL3-DH03 59

5324789 LL3-DW01-2 20/60/67

5325

5325285 LL3-DE01 36/41

5325528 LL3-DR09 36/42/72

5325608 LL3-DW02 67

5325807 LL3-TE01 37/43

5325808 LL3-TR05 37/45/76

5325906 LL3-TR11 37/45

5325907 LL3-TR12 38/45

5325908 LL3-TE03 37/43

5325909 LL3-TR13 38/46

5325910 LL3-TE02 37/43

5325911 LL3-TE04 37/43

5325912 LL3-TR06 37/45/76

5325914 LL3-TE05 37/44

5325915 LL3-TJ01 21

5325916 LL3-TB06 30

5325917 LL3-TB08 21

5325918 LL3-TR04 26/45/76

5325919 LL3-TB07 26

5325920 LL3-TR10 27/45

5325921 LL3-TG05 26/30/44

5325922 LL3-TV08 27/32

5325923 LL3-TS22V 27/31/46

5325924 LL3-TB05 51

5325925 LL3-TP01 51

5325926 LL3-TH06 26/30

5325937 LL3-TZ05 55

5325938 LL3-TZ06 55

5325940 LL3-TG01 73

5325942 LL3-TG03 73

5325943 LL3-TG02 30/40/73

5325944 LL3-TS22 31/73

5325967 LL3-TH17 62

5325968 LL3-TS22M 31/62

5325970 LL3-TH10 61

5325971 LL3-TH11 61

Appendix

Page 139: Sick Fibre Optic Sensors and Fibers

H

8014999/2012-05Subject to change without notice

1 3 9F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Index by part no.

part no. Model name page

5325972 LL3-TH12 61

5325973 LL3-TH13 62

5325974 LL3-TH14 62

5325975 LL3-TH15 30/62

5325976 LL3-TH16 30/62

5325977 LL3-TH07 30/61

5325978 LL3-TH08 61

5325979 LL3-TH09 61

5325980 LL3-TY05 65

5325981 LL3-TY04 65

5325982 LL3-TY03 32/65

5325984 LL3-TR08 31/45/73

5325985 LL3-TR09 31/45/73

5325986 LL3-DE03 36/41

5325987 LL3-DE04 36/41

5325988 LL3-DB07 17

5325989 LL3-DJ01 17

5325990 LL3-DB04 17

5325991 LL3-DB09 28

5325992 LL3-DJ02 18

5325998 LL3-DP01 25

5325999 LL3-DB10 24

5326

5326000 LL3-DR11 25

5326001 LL3-DR12 25/29/42

5326002 LL3-DB05 48

5326004 LL3-DB08 49

5326005 LL3-DR10 50

5326006 LL3-DB06 49

5326007 LL3-DR07 49

5326008 LL3-RR01 79

5326010 LL3-RB01 78

5326011 LL3-RB02 78

5326012 LL3-RG01 79

5326013 LL3-DZ01 54

5326014 LL3-DZ02 55

5326015 LL3-DZ03 55

5326016 LL3-DC05 35/71

5326017 LL3-DC06 35/40/71/74

5326018 LL3-DC04 34/40/71/74

5326019 LL3-DC07 35/71

5326020 LL3-DC03 34/70

5326021 LL3-DH05 49/59

5326022 LL3-DH04 49/59

part no. Model name page

5326023 LL3-DH10 36/59/72

5326024 LL3-DH11 36/60/72

5326025 LL3-DH08 36/72

5326026 LL3-DH06 36/59/71

5326028 LL3-DC09 35/71

5326029 LL3-DC08 35/71

5326030 LL3-DH09 59

5326031 LL3-DH07 59

5326033 LL3-DF07 67

5326034 LL3-DF05 67

5326035 LL3-DF04 67

5326037 LL3-DR08 19/75

5326598 LL3-TZ09 46/56

5326599 LL3-TZ10 56

Appendix

Page 140: Sick Fibre Optic Sensors and Fibers

H

8014999/2012-05Subject to change without notice

1 4 0 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Index by model name

Model name part no. page

ll3-DB

LL3-DB01 5308074 16

LL3-DB01-3 5322552 16

LL3-DB01-10 5308075 17

LL3-DB01-30 5324662 17

LL3-DB02 5308083 48

LL3-DB03 5313021 17

LL3-DB04 5325990 17

LL3-DB05 5326002 48

LL3-DB06 5326006 49

LL3-DB07 5325988 17

LL3-DB08 5326004 49

LL3-DB09 5325991 28

LL3-DB10 5325999 24

ll3-DC

LL3-DC03 5326020 34/70

LL3-DC04 5326018 34/40/71/74

LL3-DC05 5326016 35/71

LL3-DC06 5326017 35/40/71/74

LL3-DC07 5326019 35/71

LL3-DC08 5326029 35/71

LL3-DC09 5326028 35/71

LL3-DC38 5322472 35/71

LL3-DC39 5322513 35/71

LL3-DC47 5324268 35/41

LL3-DC57 5324269 35/41

ll3-DE

LL3-DE01 5325285 36/41

LL3-DE02 5324497 36/41

LL3-DE03 5325986 36/41

LL3-DE04 5325987 36/41

ll3-DF

LL3-DF02-S01 5321924 66

LL3-DF04 5326035 67

LL3-DF05 5326034 67

LL3-DF07 5326033 67

ll3-DH

LL3-DH01 5308091 17/58

LL3-DH01-03 5321260 17/58

LL3-DH02 5308092 17/59

LL3-DH03 5324787 59

LL3-DH04 5326022 49/59

LL3-DH05 5326021 49/59

LL3-DH06 5326026 36/59/71

Model name part no. page

LL3-DH07 5326031 59

LL3-DH08 5326025 36/72

LL3-DH09 5326030 59

LL3-DH10 5326023 36/59/72

LL3-DH11 5326024 36/60/72

ll3-DJ

LL3-DJ01 5325989 17

LL3-DJ02 5325992 18

ll3-DK

LL3-DK04 5313020 24

LL3-DK06 5313019 18

LL3-DK21 5313023 18

LL3-DK33 5313031 28/49

LL3-DK43 5313030 49

LL3-DK4Z 5313026 25/41

LL3-DK63Z 5313027 41/49

LL3-DK66 5313024 18/41

LL3-DK67 5313025 18/42

ll3-DM

LL3-DM01 5308071 18

LL3-DM02 5308077 18

LL3-DM03 5308084 49

ll3-Dp

LL3-DP01 5325998 25

ll3-Dr

LL3-DR01 5308078 18/42/75

LL3-DR02 5308079 18/42/75

LL3-DR03 5308080 25/42/75

LL3-DR04 5308081 25/42/75

LL3-DR05 5308087 25/75

LL3-DR06 5308082 19/42/75

LL3-DR07 5326007 49

LL3-DR08 5326037 19/75

LL3-DR09 5325528 36/42/72

LL3-DR10 5326005 50

LL3-DR11 5326000 25

LL3-DR12 5326001 25/29/42

ll3-Ds

LL3-DS06 5308073 19

ll3-Dt

LL3-DT01 5308076 19

LL3-DT01-05 5309087 19

LL3-DT02 5308085 42/50/75

LL3-DT03 5308072 25

Model name part no. page

LL3-DT04 5308086 43/50/75

LL3-DT05 5313028 50

ll3-DV

LL3-DV01 5308088 29/50

LL3-DV02 5308089 29/50

LL3-DV03 5308090 29/50

LL3-DV05 5322549 19/29

LL3-DV06 5322550 19/29/60

LL3-DV07 5322551 19/29/43

ll3-DW

LL3-DW01 5315234 20/60/67

LL3-DW01-2 5324789 20/60/67

LL3-DW02 5325608 67

ll3-DY

LL3-DYO1 5308093 64

ll3-DZ

LL3-DZ01 5326013 54

LL3-DZ02 5326014 55

LL3-DZ03 5326015 55

ll3-rB

LL3-RB01 5326010 78

LL3-RB02 5326011 78

ll3-rG

LL3-RG01 5326012 79

ll3-rr

LL3-RR01 5326008 79

Fiber-optic proximity systems

Appendix

Page 141: Sick Fibre Optic Sensors and Fibers

H

8014999/2012-05Subject to change without notice

1 4 1F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Index by model name

Fiber-optic through-beam systems

Model name part no. page

ll3-tB

LL3-TB01 5308050 21

LL3-TB01-10 5308051 21

LL3-TB01-30 5315499 21

LL3-TB02 5308048 21

LL3-TB03 5308056 51

LL3-TB05 5325924 51

LL3-TB06 5325916 30

LL3-TB07 5325919 26

LL3-TB08 5325917 21

ll3-tE

LL3-TE01 5325807 37/43

LL3-TE02 5325910 37/43

LL3-TE03 5325908 37/43

LL3-TE04 5325911 37/43

LL3-TE05 5325914 37/44

ll3-tF

LL3-TF01 5324242 68

ll3-tG

LL3-TG01 5325940 73

LL3-TG02 5325943 30/44/73

LL3-TG03 5325942 73

LL3-TG04 5324499 73

LL3-TG05 5325921 26/30/44

ll3-tH

LL3-TH01 5308064 21/61

LL3-TH02 5308065 21/61

LL3-TH06 5325926 26/30

LL3-TH07 5325977 30/61

LL3-TH08 5325978 61

LL3-TH09 5325979 61

LL3-TH10 5325970 61

LL3-TH11 5325971 61

LL3-TH12 5325972 61

LL3-TH13 5325973 62

LL3-TH14 5325974 62

LL3-TH15 5325975 30/62

LL3-TH16 5325976 30/62

LL3-TH17 5325967 62

ll3-tJ

LL3-TJ01 5325915 21

ll3-tK

LL3-TK05 5313034 26/44

LL3-TK16 5313038 30/51

Model name part no. page

LL3-TK77 5313035 22/44

ll3-tM

LL3-TM01 5308068 22

LL3-TM02 5308069 22

LL3-TM03 5308070 26

ll3-tp

LL3-TP01 5325925 51

ll3-tr

LL3-TR01 5308052 22/44/76

LL3-TR01-05 5322198 22/44/76

LL3-TR02 5308053 22/44/76

LL3-TR03 5308054 26/44/76

LL3-TR03-2 5308055 26/45/76

LL3-TR04 5325918 26/45/76

LL3-TR05 5325808 37/45/76

LL3-TR06 5325912 37/45/76

LL3-TR08 5325984 31/45/73

LL3-TR09 5325985 31/45/73

LL3-TR10 5325920 27/45

LL3-TR11 5325906 37/45

LL3-TR12 5325907 38/45

LL3-TR13 5325909 38/46

ll3-ts

LL3-TS07 5308049 27

LL3-TS08 5308061 31/51

LL3-TS10 5308063 55

LL3-TS12 5308062 31/51

LL3-TS14 5313039 55

LL3-TS22 5325944 31/73

LL3-TS22M 5325968 31/62

LL3-TS22V 5325923 27/31/46

LL3-TS40 5323971 55

ll3-tt

LL3-TT01 5308057 51

ll3-tV

LL3-TV01 5308058 31/51

LL3-TV02 5308059 32/52

LL3-TV04 5308060 32/52

LL3-TV05 5322546 22/32

LL3-TV06 5322547 22/32/62

LL3-TV07 5322548 22/32/46

LL3-TV08 5325922 27/32

ll3-tW

LL3-TW01 5315233 23/62/68

Model name part no. page

LL3-TW01-2 5321306 23/62/68

ll3-tX

LL3-TX01 5324173 23

ll3-tY

LL3-TY01 5308066 65

LL3-TY02 5308067 32/65

LL3-TY03 5325982 32/65

LL3-TY04 5325981 65

LL3-TY05 5325980 65

ll3-tZ

LL3-TZ05 5325937 55

LL3-TZ06 5325938 55

LL3-TZ09 5326598 46/56

LL3-TZ10 5326599 56

Appendix

Page 142: Sick Fibre Optic Sensors and Fibers

8014999/2012-05Subject to change without notice

1 4 2 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

notes

Page 143: Sick Fibre Optic Sensors and Fibers

1 4 3

M6

300°C

2

icon overview

Systems

design

Proximity system Through-beam system

Threaded sleeve

Smooth sleeve

90° deflection

Flat design

Flexible fibers

Long end sleeve

Fields of application

Area detection

Heat-resistant

Liquid level

Robotics

Retro-reflectiveOil/chemical resistant

LCDs/transparent objects/semiconductors

3 steps to finding suitable fibers

additional product information

www.sick.com/fiber

1. Icon overview

Select the design or application for the fibers. The applicable characteristics are highlighted in color in the selection table. Page 6

You can find further technical data about fibers along with dimensional drawings and 3D CAD files in the product finder for fibers at www.sick.com.

2. Fiber categories

Select the fibers that are suitable for your application.Page 16

3. Fiber-optic sensors

Select an amplifier. Page 86

General information www.mysick.com – Your quick access to maximum efficiency

Search online quickly and safely with the SicK „Finders“

Efficiency – with SicK e-commerce tools

Find out prices and availabilityDetermine the price and possible delivery date of your desired product simply and quickly at any time.

request or view a quoteYou can have a quote generated online here.Every quote is confirmed to you via e-mail.

order onlineYou can go through the ordering process in just a few steps.

Product Finder: We can help you to quickly target the pro-duct that best matches your application.

applications Finder: Select the application description on the basis of the challenge posed, industrial sector, or pro-duct group.

Literature Finder: Go directly to the operating instructions, technical information, and other literature on all aspects of SICK products.

these and other Finders at www.mysick.com

ProductApplicationsLiteratureServiceConnection diagramAccessoriesSpare partSoftware

clearly structured: You can find everything you need for your sensor planning under the menu items Pro-ducts, Information, and My Account.

available 24 hours a day: Regard-less of where you are in the world or what you would like to know – everything is just a click away at www.mysick.com.

Safe: Your data is password-pro-tected and only visible to you. With the individual user management, you define who can see what data and who can execute what actions.

8014999/2012-05Subject to change without notice

F i B E r - o P t i c P h o t o E L E c t r i c S E n S o r S | S i c K F i B E r - o P t i c P h o t o E L E c t r i c S E n S o r S | S i c K8014999/2012-05Subject to change without notice

B

8014999/2012-05Subject to change without notice

6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

selection guides Proximity systems

Model name Design Application page

LL3-DB01 M6

300°C

16

LL3-DB01-3 M6

300°C

16

LL3-DB01-10 M6

300°C

17

LL3-DB01-30 M6

300°C

17

LL3-DB02 M6

300°C

48

LL3-DB03 M6

300°C

17

LL3-DB04 M4

300°C

17

LL3-DB05 M6

300°C

48

LL3-DB06 M6

300°C

49

LL3-DB07 M3

300°C

17

LL3-DB08 M6

300°C

49

LL3-DB09 M6

300°C

28

LL3-DB10 M6

300°C

24

LL3-DC03 M6

300°C

34/70

LL3-DC04 M6

300°C

34/40/71/74

LL3-DC05 M6

300°C

35/71

LL3-DC06 M6

300°C

35/40/71/74

LL3-DC07 M6

300°C

35/71

LL3-DC08 M6

300°C

35/71

LL3-DC09 M6

300°C

35/71

LL3-DC38 M6

300°C

35/71

LL3-DC39 M6

300°C

35/71

LL3-DC47 M6

300°C

35/41

LL3-DC57 M6

300°C

35/41

Fiber-optic proximity systems

B

8014999/2012-05Subject to change without notice

7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

selection guidesProximity systems

Model name Design Application page

LL3-DE01 M6

300°C

36/41

LL3-DE02 M6

300°C

36/41

LL3-DE03 M6

300°C

36/41

LL3-DE04 M6

300°C

36/41

LL3-DF02-S01 M6

300°C

66

LL3-DF04 M6

300°C

67

LL3-DF05 M6

300°C

67

LL3-DF07 M6

300°C

67

LL3-DH01 M6

180°C

17/58

LL3-DH01-03 M6

180°C

17/58

LL3-DH02 M6

300°C

17/59

LL3-DH03 M6

350°C

59

LL3-DH04 M6

350°C

49/59

LL3-DH05 M6

350°C

49/59

LL3-DH06 M6

300°C

36/59/71

LL3-DH07 M6

200°C

59

LL3-DH08 M6

180°C

36/59/72

LL3-DH09 M6

130°C

59

LL3-DH10 M6

250°C

36/59/72

LL3-DH11 M6

250°C

36/60/72

LL3-DJ01 M3

300°C

17

LL3-DJ02 M6

300°C

18

LL3-DK04 M6

300°C

24

LL3-DK06 M6

300°C

18

LL3-DK21 M3

300°C

18

C

M6

8014999/2012-05Subject to change without notice

1 6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

threaded sleeve Proximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

threaded sleeves

Fibers with thread are easy to mount, e.g., on a mounting bracket. An even greater sensing range can be achieved with a tip adapter, which can be optionally screwed on to some models.

The LL3-TV05/06/07 and LL3-DV05/06/07 90° models with hexagonal head, for example, are ideal for space-saving mounting. These are also available as highly-flexible and heat-resistant fibers.

Fiber-optic proximity systems

Model name Minimum bend radius

Minimum object size*

tempera-ture

Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DB01 M6

25 mm Ø 0.015 mm-40 °C

–+70 °C

2 m90 1) 160 6)

5308074

280 2) 62 7)

500 3) 37 8)

900 4)

1350 5)

LL3-DB01-3 M6

25 mm Ø 0.015 mm-40 °C

–+70 °C

3 m90 1) 160 6)

5322552

280 2) 62 7)

500 3) 37 8)

900 4)

1350 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

Axial outlet Fibers with hexagon head for space-saving installation

C

8014999/2012-05Subject to change without notice

1 7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

threaded sleeveProximity systems

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Model name Minimum bend radius

Minimum object size*

temperature Fiberlength

Wll180tsensing

distance (mm)

Wll170-2sensing

distance (mm)

part no.

LL3-DB01-10M6

25 mm Ø 0.015 mm-40 °C

–+70 °C

10 m50 1) 90 6)

5308075

140 2) 27 7)

250 3) 32 8)

500 4)

750 5)

LL3-DB01-30M6

25 mm Ø 0.015 mm-40 °C

–+70 °C

30 m35 1) 63 6)

5324662

98 2) 18 7)

175 3) 25 8)

350 4)

525 5)

LL3-DB03 M6

25 mm Ø 0.015 mm-40 °C

–+70 °C

2 m90 1) 160 6)

5313021

300 2) 62 7)

500 3) 37 8)

900 4)

1350 5)

LL3-DB04 M4

25 mm Ø 0.015 mm-40 °C

–+70 °C

2 m90 1) 90 6)

5325990

280 2) 55 7)

500 3) 50 8)

900 4)

1350 5)

LL3-DB07 M3

25 mm Ø 0.02 mm-40 °C

–+60 °C

2 m27 1) 65 6)

5325988

88 2) 30 7)

165 3) 20 8)

330 4)

350 5)

LL3-DH01 M6

180°C

35 mm Ø 0.015 mm-40 °C

–+180 °C

2 m120 1) 220 6)

5308091

350 2) 95 7)

600 3) 45 8)

980 4)

1500 5)

LL3-DH01-03M6

180°C

35 mm Ø 0.015 mm-40 °C

–+180 °C

3 m100 1) 150 6)

5321260

300 2) 85 7)

500 3) 40 8)

850 4)

1400 5)

LL3-DH02 M6

100°C

25 mm Ø 0.015 mm-40 °C

–+100 °C

2 m70 1) 125 6)

5308092

230 2) 45 7)

350 3) 8 8)

600 4)

1000 5)

LL3-DJ01 M3

10 mm Ø 0.02 mm-40 °C

–+60 °C

1 m

14 1) 60 6)

5325989

49 2) 27 7)

99 3) 17 8)

190 4)

210 5)

1) Operating mode: 16 µs 2) Operating mode: 70 µs 3) Operating mode: 250 µs 4) Operating mode: 2 ms 5) Operating mode: 8 ms 6) Red light: 250 µs 7) High speed: 50 µs 8) Green light: 250 µs * With optimal measuring distance and settings. / Mounting material included.

E

8014999/2012-05Subject to change without notice

8 6 F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Amplifiers

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Fits flexibly into the narrowest corners

When installation space is extremely limited or the objects to be detected are tiny, fiber-optic sensors are the ideal solution. If it is necessary for even higher requirements to be fulfilled, such as sensing range, temperature resistance, material durability or a flexible mounting process, the intelligent combination of sensors and fibers can provide the perfect solution. A wide range of fibers with application-specific optical heads ensure that every need is met.

Your benefits • Reliable and accurate detection

of the smallest objects thanks to innovative, microcontroller-supported electronics

• EMC, high temperature tolerance and resistance to chemicals, as the evaluation electronics are mounted separately from the fiber-optic head

• Space-saving mounting even in confined spaces

• Multiple setting options provide solutions for practically any application

• Lightweight, suitable for use on a robot arm

• Universal application possibilities due to wide range of fibers

E

8014999/2012-05Subject to change without notice

8 7F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Amplifiers

F i B E r - o p t i C p H o t o E l E C t r i C s E n s o r s | s i C K

Fiber-optic sensors and fibers

product family overview 88

Wll170-2Versatility for standard applications

90

Wll180tA global leader when it comes to sensing range and performance

96

QuickFind3QuickFind2QuickFind1

Page 144: Sick Fibre Optic Sensors and Fibers

SICK AG | Waldkirch | Germany | www.sick.com

Fiber-optic sensors and fibers

Fits flexibly into the narrowest corners

Pr

od

uc

t in

Fo

rm

ati

on

Fibe

r-opt

ic s

enso

rs a

nd fi

bers

| P

rodu

ct in

form

atio

n

We can help you to quickly target the product that best matches your application.

Select the application description on the basis of the challenge posed, industrial sector, or product group.

Go directly to the operating instruc-tions, technical information, and other literature on all aspects of SICK products.

www.mysick.com – Your quick access to maximum efficiency

these and other Finders at www.mysick.com

Find out prices and availabilityDetermine the price and possible delivery date of your desired product simply and quickly.

request or view a quoteYou can have a quote generated online here. Every quote is confirmed to you via e-mail.

order onlineYou can go through the ordering process in just a few steps.

• clearly structured • available 24 hours a day • Safe

Efficiency – with SicK e-commerce tools

8014

999/

2012

-05-

31 ∙

MK

(201

2-05

) ∙ W

B US

mod

int3

7

Leading technologies

With a staff of more than 5,000 and over 50 subsidiaries and representa-tions worldwide, SICK is one of the leading and most successful manufac-turers of sensor technology. The power of innovation and solution competency have made SICK the global market leader. No matter what the project and industry may be, talking with an expert from SICK will provide you with an ideal basis for your plans – there is no need to settle for anything less than the best.

Unique product range

• Non-contact detecting, counting, classifying, positioning and measur-ing of any type of object or media

• Accident and operator protection with sensors, safety software and services

• Automatic identification with bar code and RFID readers

• Laser measurement technology for detecting the volume, position and contour of people and objects

• Complete system solutions for analy-sis and flow measurement of gases and liquids

Comprehensive services

• SICK LifeTime Services – for safety and productivity

• Application centers in Europe, Asia and North America for the develop-ment of system solutions under real-world conditions

• E-Business Partner Portal www.mysick.com – price and availabi-lity of products, requests for quotation and online orders

SicK at a glance

Worldwide presence with subsidiaries in the following countries:

australia Belgium/Luxembourg Brasil ceská republika canada china danmark deutschland España France Great Britain india israel italia Japan

méxico nederland norge Österreich Polska românia russia Schweiz Singapore Slovenija South africa South Korea Suomi Sverige taiwan türkiye united arab Emirates uSa

Please find detailed addresses and additional representatives and agencies in all major industrial nations at www.sick.com